ECGGuard: Deep Watermarking of Electrocardiogram Signals With Error-Correcting Codes

Abstract

Wearable electrocardiogram (ECG) recordings pass through multiple networks and systems before automated interpretation, leaving patient metadata vulnerable to loss. Digital watermarking can embed this metadata in the signal, but conventional methods fail under time shifts, and high waveform similarity does not guarantee the same downstream diagnosis. We present \rev{ECGGuard}, a deep watermarking framework for single-lead ECG. A fully convolutional generator embeds the payload without signal quantization, a detector decodes the message frame by frame and checks for watermark presence, and during training a frozen arrhythmia classifier penalizes changes that would alter its predictions. Because high bit accuracy does not ensure whole-message recovery, the payload is protected by extended Hamming codes, \rev{a validation-selected channel ordering}, and soft-decision decoding. On the MIT-BIH Arrhythmia Database, \rev{averaged over three training runs, ECGGuard} keeps bit accuracy above \rev{98%} under time shifts of 10 to 50 samples, where transform-domain baselines drop to chance. The coded 16-bit payload is recovered exactly in \rev{99.95%} of clean segments\rev{, in over 96%} under time shifts, 10% sample deletion, or 10% packet loss\rev{, and in 99.1% for unseen subjects}. \rev{For the guiding classifier, the diagnostic loss limits the drop in ventricular-beat sensitivity to 1.6 percentage points on the test records (35.0 without it) and to 12.2 points for unseen subjects (67.0 without it); the drop grows to 10.3 points for independently trained classifiers, and the protection does not transfer to an external database.} \rev{ECGGuard} has 0.56 million parameters and needs about \rev{19}~ms per segment on a desktop CPU.

Introduction

Electrocardiogram (ECG) monitoring is rapidly shifting from clinics to IoMT-connected wearables [1]. In typical remote pipelines, single-lead signals are collected on-body, transmitted over public networks, stored in health databases, and analyzed by automated models on-device or in the cloud [2, 3, 4, 5]. Throughout this process, recordings risk detaching from patient identity, recording context, or source devices. While authentication protocols [6] and ledger systems [7] secure networks and storage, they maintain metadata in separate records. Digital watermarking solves this by embedding metadata directly into the waveform, keeping it bound through format conversions to the point of interpretation [8]. Although common for medical images [9], [10], ECG signals require similar in-signal protection.

Most existing methods rely on heuristic embedding, including LSB substitution [11], reversible schemes [12], and transform-domain approaches using wavelets [13], [14], SVD [15], [16], curvelets [17], or Schur decomposition [18]. While these confirm that ECG signals can carry metadata with minimal distortion, three key issues hinder their practical deployment in automated pipelines:

  1. Failure under time shifts. Transform-domain methods divide signals into fixed blocks, requiring the receiver to match the exact same grid. Common transmission issues such as buffer offsets, packet loss, or resampling break this alignment and cause extraction to fail [19]. In our tests, shifting just 10 samples drops the bit accuracy of such methods to random chance (≈50%). Moreover, coefficient quantization often creates visible step-like artifacts in subtle regions like the P wave and ST segment.

  1. Waveform fidelity does not mean diagnostic safety. Most studies evaluate distortion using only signal metrics like SNR [14]. However, deep learning classifiers can misclassify under minor, structured noise [20], [21]. Thus, a high SNR alone cannot ensure that automated diagnoses remain unchanged.

  1. High bit accuracy hides packet-level failure. Average bit accuracy is a misleading metric because metadata like patient IDs requires zero bit errors to be usable. Assuming independent errors, a seemingly high 95% bit accuracy yields a fully correct 32-bit message only 0.9532≈19%0.95^{32} \approx19\% of the time.

End-to-end deep watermarking can tackle these issues, but physiological signal applications remain limited [22], [23], leaving time shifts, diagnostic safety, and full-message recovery unaddressed together. To eliminate alignment issues while preserving cardiac features, we use a lightweight, fully convolutional, quantization-free network that adds smooth residuals and decodes in real time. For diagnostic reliability, the generator trains with feedback from a downstream classifier. Finally, to ensure complete recovery, outputs are protected by error-correcting codes (ECC) [24], [25] using soft bit probabilities.

We therefore propose ECGGUard, a small (0.56 million parameters), fully convolutional, and quantization-free deep watermarking framework for single-lead ECG. Our main contributions are as follows:

  • Frame-level, quantization-free ECG watermarking: A generator–detector pair embeds and reads the message with local 1-D residual convolutions on the full-resolution signal and is trained end to end through a differentiable distortion layer. This design needs no global block alignment and keeps 98.58%–98.62% bit accuracy under circular shifts of 10 to 50 samples (means over three trained models).

  • Diagnostic fidelity constraint: During training, a frozen arrhythmia classifier adds a differentiable penalty when the watermark changes its output. A controlled sweep of the penalty weight shows that, without it, the guiding classifier loses 35.0 percentage points of ventricular-beat sensitivity, compared with 1.6 points at the selected weight (12.2 points, compared with 67.0, for subjects unseen in training). We also report where the protection is weaker: for independently trained classifiers, for unseen subjects, and on an external database.

  • Error-correcting payload protection: We show why bit accuracy and whole-message recovery differ and add a rate-0.5 coding layer with extended Hamming(8,4) codes, a channel ordering chosen on validation data, and soft maximum-likelihood decoding. This raises error-free recovery of a 16-bit message on clean segments to 99.95±0.08% and keeps it at 99.13% for subjects unseen in training.

  • Broad evaluation with clear scope: We test ECGGuard under 20 distortion conditions, separating distortions seen in training from those used only for testing, and also report a comparison at equal payload and SNR, sample deletion, packet loss, watermark-presence detection, subject-separated training, an external database, higher-SNR operating points, and run time.

The rest of this article is organized as follows. Section II reviews related work. Section III details the proposed ECGGuard framework. Section IV outlines the experimental setup, Section V presents the results, Section VI discusses the design implications and limitations, and Section VII concludes the article.

Conventional ECG Watermarking

Traditional ECG watermarking relies on handcrafted rules balancing capacity, reversibility, and robustness. Time-domain LSB substitution [11] offers high capacity but breaks under simple scaling or filtering. Reversible schemes [12] restore exact waveforms for tamper detection, yet fail under irreversible channel noise. For better noise resistance, transform-domain methods modify wavelet sub-bands [13], [14], wavelet singular values [15], [16], curvelets [17], or Schur matrices [18] (reviewed in [8]).

Despite different transforms, these methods share a bottleneck: slicing the 1-D ECG into fixed blocks or 2-D matrices requires the decoder to reconstruct the exact sample grid. In practice, timing shifts from buffer offsets, packet drops, or resampling break this alignment and cause extraction failure [19]. Furthermore, vital low-amplitude features like the P wave and ST segment often suffer from step-like artifacts caused by coefficient quantization.

Deep Learning-Based Watermarking

End-to-end deep watermarking, introduced by HiDDeN [26], jointly trains an encoder and decoder using a differentiable distortion layer to simulate transmission channels [27]–[29]. While early methods spread messages across entire images [26], [30], [31] or audio clips [32], [33], AudioSeal [34] introduced sample-level detection to tolerate time cropping and splicing.

However, image and audio models rely on perceptual losses based on human vision or hearing. In ECGs, subtle low-amplitude waveforms which such losses might ignore as background often carry vital diagnostic cues. ECGGuard adopts the local, frame-level design of AudioSeal [34] but replaces perceptual objectives with cardiac-specific spectral and diagnostic losses. Deep watermarking for physiological signals remains rare: Hsu et al. [22] used a variational autoencoder for ECG sensor assessment, while Zhang et al. [23] applied a dual-stream attention network to EEG. Neither work addresses time shifts, diagnostic safety, and full-message recovery together.

Diagnostic Effect of Watermarks on ECG Classifiers

Prior ECG watermarking studies typically evaluate signal quality using waveform metrics like SNR or percentage root-mean-square difference [8], [14]. In modern clinical pipelines, however, watermarked signals are analyzed by automated 1-D convolutional or residual arrhythmia classifiers [2], [35]–[37]. Two factors explain why high SNR alone cannot guarantee diagnostic safety. First, deep classifiers often rely on features different from those prioritized by cardiologists [38], so a high-SNR watermark can still alter features that drive model predictions. Second, deep ECG models are vulnerable to minor, structured perturbations [20], [21], [39]. Because a learned watermark is itself a structured perturbation across the signal, its diagnostic impact must be constrained during training and evaluated directly with class-sensitive metrics under an inter-patient protocol [3], [40], [41], where rare arrhythmia classes are particularly sensitive.

Error-Correcting Codes for Watermark Payloads

A watermarking system acts as a communication channel disturbed by both the host signal and transmission noise, meaning message reliability depends on both raw bit error rates and channel coding. Extended Hamming codes provide single-error correction and double-error detection (SECDED) [24], [25], while soft-decision decoding further boosts performance by using bit-level confidence [42]. Although deep image watermarking has used BCH codes [27], [28], these methods typically rely on hard 0/1 decisions, discarding the soft bit probabilities output by the neural detector. Similarly, prior ECG studies report average bit accuracy or correlation rather than full-message recovery rates. In § 3-F, we pair extended Hamming codes with reliability-based channel ordering and soft maximum-likelihood decoding to exploit the uneven bit confidence of our detector.

Proposed Method

Figure 1 shows the overall design of ECGGuard. The error-correcting code layer (§ 3-F) is added around the trained generator and detector and does not change their weights.

Overview of ECGGuard

Figure 1. Overview of ECGGuard. (a) Training. The generator GG and the detector DD are trained together through a differentiable distortion layer AA. From an ECG segment xx and a binary message mm, GG produces a watermarked ECG yy. GG is guided by the reconstruction loss Lrec\mathcal{L}_{rec}, the spectral loss Laux\mathcal{L}_{aux}, and the diagnostic loss Ldiag\mathcal{L}_{diag}, which keeps the class probabilities of a frozen classifier CC (bar charts) the same for xx and yy. DD reads the distorted ECG y′y', outputs pwmp_{wm} and the bit probabilities qq, and is trained with the presence loss Ldet\mathcal{L}_{det} and the message loss Lmsg\mathcal{L}_{msg}; their gradients also reach GG through AA. (b) Use with the error-correcting code layer. At the sender, the 16-bit message uu is encoded with four extended Hamming(8,4) codes and mapped to the 32 channel bits mm by the reliability-based channel ordering π\pi (§ 3-F), and GG embeds mm into xx. After the channel T\mathcal{T}, DD estimates the presence probability pwmp_{wm} and the bit probabilities qq, which are reordered with π−1\pi^{-1} and decoded by soft maximum-likelihood decoding into u^\hat{u}. The coding layer has no trainable parameters and is added after training. The watermarked yy can be passed to clinical analysis without realignment.

Problem Formulation and Design Requirements

Let x∈RT\mathbf{x} \in\mathbb{R}^{T} be a single-lead ECG segment with TT samples, and let m∈{0,1}N\mathbf{m} \in\{0,1\}^{N} be the binary message, where NN is the number of channel bits per segment. The generator GG embeds the message by adding a scaled, learned residual Rθ(x,m)R_{\theta}(\mathbf{x},\mathbf{m}) to the signal:

y=G(x,m)=x+αRθ(x,m),(1)\mathbf{y}=G(\mathbf{x},\mathbf{m})=\mathbf{x}+\alpha R_{\theta}(\mathbf{x},\mathbf{m}), \tag*{(1)}

where y∈RT\mathbf{y} \in\mathbb{R}^{T} is the watermarked segment and α\alpha is a global embedding strength. During transmission and storage, the signal goes through an unknown distortion T\mathcal{T}, and the receiver gets y′=T(y)\mathbf{y}^{\prime}=\mathcal{T}(\mathbf{y}). The detector DD then reads y′\mathbf{y}^{\prime} directly:

(pwm,q)=D(y′),(2)(p_{wm},\mathbf{q})=D(\mathbf{y}^{\prime}), \tag*{(2)}

and outputs the probability pwm∈[0,1]p_{wm} \in[0,1] that a watermark is present and the bit probabilities q∈[0,1]N\mathbf{q} \in[0,1]^{N}. Without coding, each bit is decided by a threshold, m^i=1[qi>0.5]\hat{m}_{i}=\mathbb{1}[q_{i}>0.5]. In this study, each segment has T=1,024T=1{,}024 samples (≈2.84\approx2.84 s at 360 Hz) and carries N=32N=32 channel bits.

Extraction is blind: the detector needs neither the original ECG x\mathbf{x} nor any extra synchronization information. We consider non-malicious distortions T\mathcal{T} that commonly occur during acquisition, transmission, and preprocessing (Section IV-C). ECGGuard does not use a secret key or a digital signature, so protection against deliberate removal or forgery is outside the scope of this work. The design has three goals: waveform fidelity (y≈x\mathbf{y}\approx\mathbf{x}), diagnostic consistency (an arrhythmia classifier CC gives the same output for x\mathbf{x} and y\mathbf{y}), and message reliability (the whole message is recovered correctly from y′\mathbf{y}^{\prime}).

Frame-Level Neural Architecture

Both GG and DD are fully convolutional networks that work on the 1-D ECG at its original sampling rate. The generator has an encoder–bottleneck–decoder structure made of 1-D residual convolution blocks. Each message bit selects one of two learned embedding vectors. Their sum is repeated along the time axis, added to the ECG features in the bottleneck, and then processed by the residual convolutions of the decoder. The features stay continuous: no vector quantization or codebook lookup is used. This lets the residual RθR_{\theta} make smooth, small changes to the waveform instead of the step-like changes that a discrete bottleneck can cause.

The detector DD uses local 1-D convolutions to estimate watermark presence and message bits at every time step (frame). These frame-level probabilities are then averaged over time to give pwmp_{wm} and q\mathbf{q} for the whole segment. Because convolution is shift-equivariant, a time shift of the input mainly moves the frame-level evidence instead of destroying it, so the averaged output depends little on exact sample alignment. Unlike block-transform methods, the detector does not need to rebuild a fixed coefficient grid. This makes it robust to circular shifts and lets it recover part of the evidence when some samples are deleted; when too much of the signal is lost, however, performance still drops (§ 5-B).

Differentiable Distortion Layer

To make the watermark robust, a random distortion layer A\mathcal{A} is placed between GG and DD during training. For each mini-batch, A\mathcal{A} applies, with probability 0.6, additive white Gaussian noise (AWGN), 1-D Gaussian smoothing, amplitude scaling, or a circular time shift, at the severities listed in Section IV-C. All four operations are differentiable, so the gradients from DD flow back through A\mathcal{A} into GG. This pushes the generator to place the watermark in signal components that survive these distortions rather than in fragile high-frequency details. Like the noise layers used in image watermarking [26], [27], [29], A\mathcal{A} simulates the expected transmission channel. To test distortions not seen in training, band-pass filtering, amplitude quantization, resampling, sample deletion, and packet loss are used only for evaluation (Section IV-C).

Training Objectives

The generator and detector are trained together by minimizing

Ltotal=λrecLrec+λmsgLmsg+λdetLdet+λdiagLdiag+Laux,(3)\mathcal{L}_{\mathrm{total}}=\lambda_{\mathrm{rec}}\mathcal{L}_{\mathrm{rec}}+\lambda_{\mathrm{msg}}\mathcal{L}_{\mathrm{msg}}+\lambda_{\mathrm{det}}\mathcal{L}_{\mathrm{det}} +\lambda_{\mathrm{diag}}\mathcal{L}_{\mathrm{diag}}+\mathcal{L}_{\mathrm{aux}}, \tag*{(3)}

where the weights λ\lambda balance waveform fidelity, message reliability, and diagnostic consistency.

Reconstruction and spectral losses. The mean squared error (MSE) keeps the watermarked ECG y\mathbf{y} close to the original x\mathbf{x} in the time domain:

Lrec=1T∑t=1T(xt−yt)2.(4)\mathcal{L}_{\mathrm{rec}}=\frac{1}{T}\sum_{t=1}^{T}(x_{t}-y_{t})^{2}. \tag*{(4)}

The MSE alone does not control which frequency bands carry the watermark, so we add spectral losses in the Fourier and continuous wavelet domains [43]:

Laux=λff∥F(x)−F(y)∥22+λcwt∥W(x)−W(y)∥22,(5)\mathcal{L}_{\mathrm{aux}}=\lambda_{ff}\lVert\mathcal{F}(\mathbf{x})-\mathcal{F}(\mathbf{y})\rVert_{2}^{2}+\lambda_{cwt}\lVert\mathcal{W}(\mathbf{x})-\mathcal{W}(\mathbf{y})\rVert_{2}^{2}, \tag*{(5)}

where F(⋅)\mathcal{F}(\cdot) and W(⋅)\mathcal{W}(\cdot) denote the fast Fourier transform and continuous wavelet transform, respectively. We use the orthonormal transform, so by Parseval’s theorem the Fourier term equals TT times the time-domain MSE and only raises the effective weight of Lrec\mathcal{L}_{\mathrm{rec}}. The frequency-selective constraint comes from the CWT term, computed with complex Morlet wavelets (ω0=6\omega_0 = 6) at 16 logarithmically spaced frequencies from 0.5 to 100 Hz.

Message and detection losses. Message decoding is trained with the binary cross-entropy (BCE) between the embedded bits mm and the predicted probabilities qq:

Lmsg=−1N∑i=1N[milog⁡qi+(1−mi)log⁡(1−qi)].(6)\mathcal{L}_{msg} = -\frac{1}{N}\sum_{i=1}^{N}\left[m_i \log q_i + (1-m_i)\log(1-q_i)\right]. \tag*{(6)}

To avoid false detections on ECGs without a watermark, distorted clean segments x′∼A(x)x' \sim A(x) are also given to DD during training, with a binary presence loss [34]:

Ldet=−[Ey′∼A(y)log⁡pwm(y′)+Ex′∼A(x)log⁡(1−pwm(x′))].(7)\mathcal{L}_{det} = -\left[\mathbb{E}_{y'\sim A(y)}\log p_{wm}(y') + \mathbb{E}_{x'\sim A(x)}\log\left(1-p_{wm}(x')\right)\right]. \tag*{(7)}

Diagnostic fidelity loss. A high SNR does not guarantee that a classifier gives the same diagnosis for xx and yy [20]. We therefore use a frozen, pre-trained five-class arrhythmia classifier CC based on a 1-D ResNet [36, 37] and penalize the Kullback–Leibler (KL) divergence between its outputs:

Ldiag=DKL(C(x)∥C(y))=∑k=1KCk(x)log⁡Ck(x)Ck(y),(8)\mathcal{L}_{diag} = D_{\mathrm{KL}}\left(C(x)\mathbin{\|}C(y)\right) = \sum_{k=1}^{K} C_k(x)\log\frac{C_k(x)}{C_k(y)}, \tag*{(8)}

where K=5K = 5 is the number of AAMI heartbeat classes. CC sees the 300 samples from 100 samples before to 200 samples after the central R peak, so Ldiag\mathcal{L}_{diag} constrains the residual only in this window. Gradients pass through the frozen CC into GG and discourage residuals that change the prediction. Because only one classifier guides training, we also check diagnostic consistency with class-level metrics, separately trained classifiers, unseen subjects, and an external database (§ 5-E and V-G).

Training Dynamics

Three simple measures keep the joint training stable. First, the embedding strength α\alpha in (1) is lowered from 0.5 to 0.15 with a cosine schedule [44] over the first 70% of the epochs, so the detector receives a strong signal early on and the watermark becomes less visible later. Second, following the two-time-scale update rule [45], the learning rate of DD is 1.5×1.5\times that of GG. Third, an exponential moving average (decay 0.999) of the weights of both networks is kept to reduce fluctuations on the validation set. These averaged weights are used for validation, calibration, and testing. The checkpoint with the highest channel-bit accuracy at the final strength α=0.15\alpha= 0.15 on held-out DS1 validation segments is kept, so no DS2 segment is used for this choice.

Payload Protection With Error-Correcting Codes

The trained network gives N=32N = 32 noisy bit channels per segment. We first explain why sending 32 uncoded bits over these channels gives poor message reliability, and then describe a light coding layer that turns them into a reliable 16-bit message without retraining GG or DD.

From Bit Accuracy to Message Reliability

Let pjp_j be the error probability of channel jj and pˉ=1N∑j=1Npj\bar{p} = \frac{1}{N}\sum_{j=1}^{N}p_j the mean error rate, so the average bit accuracy is 1−pˉ1-\bar{p}. If errors are independent, the probability that an uncoded NN-bit message has no error is

Pexactunc=∏j=1N(1−pj)≤(1−pˉ)N,(9)P_{\mathrm{exact}}^{\mathrm{unc}} = \prod_{j=1}^{N}(1-p_j) \leq(1-\bar{p})^N, \tag*{(9)}

where the inequality follows from the inequality of arithmetic and geometric means. (9) shows two things. First, the chance of a fully correct message falls exponentially with the message length NN: at the mean clean bit accuracy of our three trained models, 1−pˉ=98.62%1-\bar{p}=98.62\%, even this upper bound, which assumes independent errors, is only 64.1% for N=32N=32. Second, for the same average accuracy, uneven channel reliability lowers this chance even more. The same unevenness, however, can be used to our advantage by putting the information bits on the most reliable channels, which we do and verify in § 5-B.

Extended Hamming(8,4) Code

A 16-bit message u∈{0,1}16\mathbf{u}\in\{0,1\}^{16} is split into four 4-bit blocks u(b)\mathbf{u}^{(b)} (b=1,…,4b=1,\ldots,4). Each block is encoded with the systematic extended Hamming(8,4) code C8,4C_{8,4} [24, 25] as c(b)=u(b)G8,4\mathbf{c}^{(b)}=\mathbf{u}^{(b)}G_{8,4} over GF(2), with the generator matrix

G8,4=[10001101010010110010011100011110],(10)G_{8,4}= \begin{bmatrix} 1&0&0&0&1&1&0&1\\ 0&1&0&0&1&0&1&1\\ 0&0&1&0&0&1&1&1\\ 0&0&0&1&1&1&1&0 \end{bmatrix}, \tag*{(10)}

where the first four columns copy the information bits and the last four add three Hamming parity bits and one overall parity bit (other systematic forms only reorder the parity columns). Each block has 16 valid codewords and a minimum Hamming distance of dmin⁡=4d_{\min}=4, so hard decoding corrects one error and detects two (SECDED). The four 8-bit codewords together form the N=32N=32 channel bits embedded by GG, giving a code rate of R=0.5R=0.5, i.e., 16 information bits per segment.

If all channels have the same independent error rate pp, hard decoding of a block succeeds when it contains at most one error:

Pblkhard=(1−p)8+8p(1−p)7,Pexacthard=(Pblkhard)4.(11)P_{\mathrm{blk}}^{\mathrm{hard}}=(1-p)^8+8p(1-p)^7,\qquad P_{\mathrm{exact}}^{\mathrm{hard}}=\left(P_{\mathrm{blk}}^{\mathrm{hard}}\right)^4. \tag*{(11)}

At the mean clean error rate p=1.38%p=1.38\%, (11) predicts 98.0% fully correct messages, compared with 64.1% for uncoded 32 bits and 80.0% for uncoded 16 bits (Figure 2). Our full coding layer reaches a higher rate (99.95%, i.e., a failure rate of 0.05% instead of 2.0%) because it adds two steps that use the uneven channel reliability and the bit probabilities.

Exact-message recovery versus channel-bit error rate

Figure 2. Exact-message recovery versus channel-bit error rate pp when all channels have the same independent error rate (curves, from (9) and (11)). Markers are measured on clean DS2 segments for the three trained models, each at its own mean error rate (p=0.02%,0.91%,p=0.02\%, 0.91\%, and 3.22%3.22\%). The uncoded 32-bit results lie close to their curve, so the exponential loss with message length dominates. The soft ECC results lie on or above the hard-decoding curve because they combine reliability-based channel ordering with soft ML decoding.

Reliability-Based Channel Ordering

A fixed permutation π\pi maps the 32 codeword positions to the 32 channels of the network. To build π\pi, we measure the error rate ϵ^j\hat{\epsilon}_j of each channel jj only on a held-out validation subset of DS1, averaged over the clean condition and circular shifts of +10, +30, and +50 samples. The 16 most reliable channels (lowest ϵ^j\hat{\epsilon}_j) carry the information bits, and the other 16 carry the parity bits. π\pi is fixed before any DS2 testing, separately for each trained model, and kept the same for all message seeds and distortions. At the receiver, the probabilities are reordered back as q~=π−1(q)\tilde{\mathbf{q}}=\pi^{-1}(\mathbf{q}) before decoding.

Soft-Decision Maximum-Likelihood Decoding

A hard threshold at 0.5 throws away the confidence information in q\mathbf{q}. Following soft-decision decoding [42], we decode each 8-bit block by exact maximum likelihood (ML) over all 16 valid codewords. Let q(b)∈[0,1]8\mathbf{q}^{(b)}\in[0,1]^8 be the reordered bit probabilities of block bb. Treating the channels as independent Bernoulli variables gives the soft ML rule

c^(b)=arg⁡max⁡c∈C8,4∑i=18[cilog⁡(q~i(b))+(1−ci)log⁡(1−q~i(b))].(12)\hat{\mathbf{c}}^{(b)}=\underset{\mathbf{c}\in C_{8,4}}{\arg\max}\sum_{i=1}^{8}\left[c_i\log\left(\tilde{q}^{(b)}_i\right)+(1-c_i)\log\left(1-\tilde{q}^{(b)}_i\right)\right]. \tag*{(12)}

Removing terms that do not depend on c\mathbf{c}, (12) becomes the maximization of ∑i=18ciℓi(b)\sum_{i=1}^{8}c_i\ell_i^{(b)} with the log-likelihood ratios ℓi(b)=log⁡(q~i(b)/(1−q~i(b)))\ell_i^{(b)}=\log\left(\tilde{q}_i^{(b)}/(1-\tilde{q}_i^{(b)})\right); probabilities are clipped to [ϵ,1−ϵ][\epsilon,1-\epsilon] for numerical stability. The four information bits of each decoded codeword c^(b)\hat{\mathbf{c}}^{(b)} form the recovered 16-bit message u^\hat{\mathbf{u}}. Hard decoding fails when two or more bits in a block are wrong. Soft ML decoding can still succeed in that case if the wrong bits have low confidence and the information bits have high confidence, which is what the reliability-based channel ordering aims for.

Checking all 4×16=644\times16=64 codewords per segment needs only simple inner products, which is negligible compared with one pass through the network (0.28 ms per segment on one CPU thread, Section V-H). The coding layer has no trainable parameters, so the code can be changed after training. Because ML decoding always returns the closest valid codeword, it corrects errors but does not reject badly damaged segments unless a confidence threshold is added, and it does not replace cryptographic authentication.

Experimental Setup

Dataset and Evaluation Protocol

All experiments use the MIT-BIH Arrhythmia Database [46], which contains 48 half-hour, two-channel ambulatory recordings sampled at 360 Hz with cardiologist-verified beat labels. The dataset is publicly available via PhysioNet [47]1, and because it is public and de-identified, no ethical approval was required. All segments are single-lead and T=1,024T=1{,}024 samples long (≈2.84\approx2.84 s). We use the first channel of each record, which is MLII in all records used here except 114 (V5). Following the inter-patient protocol of Chazal et al. [40], we exclude the four paced records (102, 104, 107, and 217) and split the remaining 44 records equally into DS1 (records 101, 106, 108, 109, 112, 114, 115, 116, 118, 119, 122, 124, 201,

203, 205, 207, 208, 209, 215, 220, 223, and 230) and DS2 (records 100, 103, 105, 111, 113, 117, 121, 123, 200, 202, 210, 212, 213, 214, 219, 221, 222, 228, 231, 232, 233, and 234), with 22 records each. Each annotated beat whose 1,024-sample window, centered on its R peak, lies inside the record gives one segment, and amplitudes are z-scored per record, clipped at ±5\pm5, and divided by 5. This yields 50,942 DS1 and 49,634 DS2 segments, with beat labels mapped to the five AAMI classes (N, S, V, F, and Q). All DS2 results, including the diagnostic ones, use these 49,634 segments, except Table 1, which uses a 2,200-segment subset.

GroupConditionECGGuard (Ours)LSB [11]DCT-SVD [15, 16]Schur. [18]
Payload (bits)32161616
Clean SNR (dB)11.1086.0626.5532.57
Shift†+1098.6249.8550.38_50.89_
Shift†+3098.60_50.30_50.2650.04
Shift†+5098.5850.1150.1450.36
Resamp.↓ 2 ↑ 295.6050.4887.4250.97
Resamp.↓ 4 ↑ 4_58.16_50.3970.0850.22
FilterBP 0.5–100 Hz96.2249.52_83.62_52.88
Smooth.†σ=1\sigma= 198.5150.29_63.09_51.02
Smooth.†σ=3\sigma= 396.7449.97_50.73_50.41
Ampl.†Scale ×0.898.5350.43_78.37_98.53
Ampl.†Scale ×1.2_98.57_50.4381.6999.77
AWGN†10 dB84.5549.84_80.22_66.97
AWGN†15 dB94.2149.88_92.66_78.11
AWGN†20 dB_97.77_50.1399.1090.87
AWGN†30 dB98.5850.0899.99_99.89_
Quant.8-bit98.6150.24_99.52_99.99
Quant.6-bit98.5050.30_99.43_99.72
NoneClean_98.63_100.00100.00100.00
Mean (16 distorted)94.4050.14_77.29_71.29
Mean (all 17 cond.)94.6553.07_78.63_72.98

Table 1. Channel-bit accuracy (%) under distortions in the original (unmatched) setting.

We partition the data as follows: (i) the diagnostic classifier CC is trained on the other 18 DS1 records and tested on DS2, and its epoch is selected on the last four DS1 records (215, 220, 223, and 230); (ii) the watermarking network is trained on a random 80/20 split of the segments of all 44 records rather than a patient-separated split, so 79.8% of the DS2 test segments were also used to train GG and DD (see Section VI-B for implications and § 5-G for a subject-separated protocol); and (iii) all tunable parameters are selected on held-out DS1 validation data and fixed before DS2 testing: the watermark checkpoint and λdiag\lambda_{diag} (§ 3-E and IV-E), the baseline embedding strengths (Section IV-B), and the ECC channel ordering (§ 3-F). For GG and DD, the validation data are the 10,104 DS1 segments that are not used for gradient updates.

Unseen subjects and external data. To test generalization beyond this protocol, we also train and test on a subject-separated split of the 44 records. Records 201 and 202 come from the same subject and are merged, giving 43 subjects, which are split into 25 training, 9 validation, and 9 test subjects. The classifier and the watermarking network are trained only on the training subjects, model selection and π\pi use only the validation subjects, and the 20,180 test segments come from subjects never seen in training. The weight λdiag\lambda_{diag} is kept at the value selected under the DS1/DS2 protocol. As an external test, the DS1/DS2 models are applied without retraining or recalibration to the St.-Petersburg INCART 12-lead arrhythmia database [47], [48]: 75 thirty-minute records from 32 patients, lead II resampled from 257 to 360 Hz and normalized as above, giving 175,606 beat-centered segments. This protocol was fixed before any INCART result was computed.

Baselines

We compare ECGGuard against three representative handcrafted methods: LSB substitution [11], a DCT-SVD method representing SVD-based transform watermarking [15], [16], and SchurMark [18], all implemented by us following the cited descriptions. We evaluate two settings:

  • Original setting (Table I). Each baseline embeds 16 bits at its default strength (DCT-SVD α=0.1\alpha= 0.1, SchurMark α=0.05\alpha= 0.05; LSB has no strength parameter), whereas ECGGuard embeds 32 channel bits. Since payload size and distortion levels differ, this setting simply illustrates how each method responds to individual distortions.

  • Matched setting (Table III). All methods embed 16 information bits, with ECGGuard using the rate-0.5 ECC layer (ECGGuard-ECC16). The embedding strengths of DCT-SVD and SchurMark are tuned on the DS1 validation subset to match the clean SNR of ECGGuard-ECC16, separately for each trained model, then fixed. Notably, both transform baselines require the original signal for extraction (non-blind), whereas ECGGuard operates blindly.

Condition / PropertyECGGuard-ECC16 (Ours)DCT-SVD [15, 16]SchurMark [18]
ExtractionBlindNon-blindNon-blind
Clean SNR (dB)11.1311.1011.10
Clean99.95100.00100.00
Shift +1099.940.000.00
Shift +3099.930.000.00
Shift +5099.930.000.00
AWGN 20 dB99.48100.00100.00
Band-pass 0.5–100 Hz96.1118.740.00

Table III. TABLE III Matched Comparison at 16 Effective Bits: Exact Recovery (%) on DS2. Bold and underlined values are the best and second-best results. Baseline strengths are tuned on DS1 validation data to match the clean SNR of ECGGuard-ECC16 (separately for each of the three trained models) and fixed before testing on DS2. Values are means over the three trained models on all 49,634 DS2 segments with one message seed per model. For ECGGuard-ECC16, the SD is at most 0.35 pp, except 6.17 pp for band-pass filtering. LSB [11] is omitted because it fails under every distortion in Table I.

Distortions

We evaluate robustness across 20 distortion conditions. During training, the distortion layer A\mathcal{A} incorporates four categories: AWGN (10, 15, 20, and 30 dB SNR), Gaussian smoothing (σ=1\sigma= 1 and 3 samples), amplitude scaling (0.8×\times and 1.2×\times), and circular time shifts (+10+10, +30+30, and +50+50 samples). To test generalization to unseen channel impairments, we further introduce band-pass filtering (0.5–100 Hz), 8-bit and 6-bit amplitude quantization, resampling by factors of 2 and 4, 10% sample deletion at the front or middle of the segment, and packet loss of 10% and 50% (randomly chosen 32-sample packets are set to zero). We distinguish between desynchronization without data loss (circular shifts) and true data-loss conditions (sample deletion and packet loss), reporting their results separately for clarity.

Metrics

Fidelity. The SNR of the watermarked signal is SNR=10log⁡10(∥x∥22/∥x−y∥22)\mathrm{SNR} = 10\log_{10}\left(\lVert x \rVert_2^2/\lVert x-y \rVert_2^2\right), averaged over segments.

Payload. Channel-bit accuracy is the share of channel bits that are decoded correctly. Exact-message recovery is the share of segments in which all message bits are correct: 32 bits for the uncoded message and 16 bits for the coded message. We train three models with different random seeds, and each model is evaluated with three message seeds that draw new messages and distortions for all 49,634 DS2 segments. We average over message seeds, unless stated otherwise, report the mean and standard deviation over the three trained models.

Detection. Watermark-presence detection is measured on clean and watermarked DS2 segments with the area under the ROC curve (AUROC) and the false-positive (FPR) and false-negative (FNR) rates at the threshold pwm=0.5p_{wm}=0.5.

Diagnosis. Most DS2 beats are Class N, so overall accuracy alone is misleading; we also report macro-F1, the sensitivity (recall) of each class (N, S, V, F, Q) [3], and the share of Class-V beats labeled N (V→\rightarrowN). Unless stated otherwise, the classifier is trained on clean DS1 and applied, without retraining, to watermarked DS2 signals (Clean→\rightarrowWatermarked). This matches a deployment in which an already-validated model is kept fixed.

Implementation

The payload has N=32N = 32 channel bits, the final embedding strength is α=0.15\alpha= 0.15, and training follows § 3-E. GG and DD are trained for 300 epochs with batch size 32 using AdamW (learning rate 10−410^{-4} for GG and 1.5×10−41.5 \times10^{-4} for DD, weight decay 10−410^{-4}, five warm-up epochs followed by cosine decay). The loss weights are λrec=1\lambda_{rec} = 1, λmsg=8\lambda_{msg} = 8, λdet=2\lambda_{det} = 2,

Bold and underlined values are the best and second-best results. †Distortion type and severity also used during ECGGuard training (Section IV-C). Shifts are in samples; Schur. = SchurMark. ECGGuard values are means over three trained models (SD 1.1–4.5 pp), and the baselines do not depend on the trained model. All methods use the same 2,200 DS2 segments (100 per record) and messages. Payload lengths and SNRs differ, so this table describes robustness rather than a matched comparison (see Table III). Bit accuracy does not tell whether the whole message is correct (see Table II).

ConditionRaw systematicSoft ECC (Ours)Δ\Delta (pp)
Clean99.47 ± 0.7999.95 ± 0.08+0.48
Shift +1099.43 ± 0.8499.94 ± 0.09+0.52
Shift +3099.31 ± 0.9899.94 ± 0.10+0.63
Shift +5099.20 ± 1.1799.93 ± 0.11+0.74
Front deletion 10%96.82 ± 4.5998.00 ± 3.43+1.18
Middle deletion 10%95.35 ± 5.7597.62 ± 3.96+2.27
Packet loss 10%90.60 ± 6.1196.73 ± 4.18+6.13
Packet loss 50%13.96 ± 3.5433.01 ± 14.34+19.05

Table II. TABLE II Exact 16-Bit Message Recovery (%, Mean ± SD Over Three Trained Models) on 49,634 DS2 Segments. 16 logical bits in 32 channel bits (code rate 0.5). Raw systematic: the 16 information channels are read directly and the parity bits are ignored. Soft ECC: ML decoding in (12). The channel ordering is chosen on DS1 validation data for each model and is the same for all rows. Each model is first averaged over three message seeds.

λfft=10−3\lambda_{fft} = 10^{-3}, λcwt=10−4\lambda_{cwt} = 10^{-4}, and λdiag=0.1\lambda_{diag} = 0.1. The guiding classifier CC is a 1-D ResNet with 445,413 parameters (a stem convolution, five residual blocks, global average pooling, and a linear layer), trained for 60 epochs on clean DS1 without class rebalancing, and the epoch with the highest macro-F1 on the four DS1 validation records is kept. We trained λdiag∈{0,0.05,0.1,0.5}\lambda_{diag} \in\{0, 0.05, 0.1, 0.5\} and selected 0.1 with a rule that was written down before the choice and uses only DS1 data of the first training seed (DS2 results were not used): among the weights that reach at least 90% bit accuracy on clean and shifted DS1 validation segments, take the one with the smallest drop in Class-V sensitivity on the four DS1 validation records. Every configuration is trained with three random seeds. Run time is measured with batch size one on one thread of an x86 64 desktop CPU and on an NVIDIA RTX 4090 GPU.

Results

Robustness to Signal Distortions

Table I summarizes bit accuracy across clean signals and 16 distortion conditions. Under circular shifts (+10, +30, and +50 samples), ECGGuard maintains 98.58%–98.62% accuracy, whereas all three handcrafted baselines drop to random chance (49.85%–50.89%), highlighting the main strength of our frame-level design. Under twofold resampling, band-pass filtering, and Gaussian smoothing, ECGGuard achieves 95.60%–98.51% even though resampling and filtering were unseen during training, while DCT-SVD and SchurMark fall to 50.41%–87.42%. Fourfold resampling is the exception: ECGGuard drops to 58.16%, below DCT-SVD (70.08%). ECGGuard also leads under severe 10- and 15-dB AWGN (84.55% and 94.21%), whereas SchurMark matches or exceeds it under amplitude scaling (98.53% and 99.77% vs. 98.53% and 98.57%). Under moderate noise (20–30 dB) and amplitude quantization, transform-domain methods mostly score higher (e.g., 99.10% for DCT-SVD vs. 97.77% for ECGGuard at 20 dB) because spreading bits across coefficient blocks helps average out broadband noise when alignment holds. Even so, ECGGuard consistently exceeds 97% in these settings, while LSB fails across all distortions. Overall, ECGGuard averages 94.40% accuracy across the 16 distortions, outperforming DCT-SVD (77.29%) and SchurMark (71.29%) by over 17 percentage points (pp). On clean signals, ECGGuard reaches 98.63% compared with 100% for handcrafted methods; eliminating this residual error is the primary motivation for our error-correcting code (ECC) layer.

Message-Level Reliability With Error-Correcting Codes

Across the 49,634 DS2 test segments, the three trained models achieve a 98.62 ± 1.65% mean clean bit accuracy (varying slightly from the 98.63% in Table I, which uses a 2,200-segment subset). Despite this high bit-level score, an uncoded 32-bit message is recovered without any bit errors in only 68.68% of segments on average, and in 31.75% for the model with the lowest bit accuracy (96.78%), because even a single flipped bit corrupts the entire payload. These rates lie close to the value (1−pˉ)32(1-\bar{p})^{32} of (9) at each model’s own bit accuracy (74.60% vs. 74.68%, 99.69% vs. 99.46%, and 31.75% vs. 35.07%; Figure 2), so the exponential loss with message length dominates. The best model slightly exceeds this value because bit errors within a segment are positively correlated, which (9) does not model, and the mean of 68.68% exceeds the 64.1% of Section III-F because that value is computed from the mean bit accuracy of three quite different models. Consequently, raw network outputs cannot be used directly as 32 reliable information bits without error-correcting codes.

Table II shows how often the coded 16-bit message is fully correct. To separate the effect of decoding from the effect of channel ordering, both columns use the same ordering π\pi: raw systematic only reads the 16 reliable information channels and ignores the parity bits, while soft ECC uses the full ML decoder in (12).

Effect of channel ordering. Reading only the information channels already gives 99.47% fully correct messages on clean data, far above the 80.0% expected for 16 channels with equal error rates of p=1.38%p = 1.38\%. Measured directly, the 16 information channels have a mean clean error rate of 0.04% (0.003%–0.10% across models), whereas the 16 parity channels have 2.73% (0.03%–6.34%). The ordering thus moves the noisy channels to parity positions, where soft decoding can handle their errors.

Effect of soft decoding. Soft ECC is better than raw systematic decoding in all eight conditions. On clean segments it reaches 99.95 ± 0.08%, which cuts the message failure rate from 0.53% to 0.05%, about ten times lower. The gain is larger when part of the signal is lost: +2.27 pp under 10% middle deletion, +6.13 pp under 10% packet loss, and +19.05 pp under 50% packet loss, where the parity bits supply the missing information. Under circular shifts, both decoders stay above 99% because the frame-level detector is hardly affected by the shift (Table I). The benefit of coding therefore depends on the distortion.

Deletion and packet loss. With soft ECC, the 16-bit message is fully correct in 98.00%, 97.62%, and 96.73% of segments under 10% front deletion, 10% middle deletion, and 10% packet loss, even though none of these distortions was used in training. The model with the lowest bit accuracy is the weakest here (94.04%, 93.05%, and 91.92%). Under 50% packet loss, the rate drops to 33.01% (21.40%–49.05% across models), which marks a clear limit (Section VI-B).

Capacity- and SNR-Matched Comparison

Table III removes the payload mismatch of Table I: all methods carry 16 information bits at about the same clean SNR (≈ 11 dB). Under circular shifts of +10, +30, and +50 samples, ECGGuard-ECC16 recovers the full message in 99.94%, 99.93%, and 99.93% of segments, while DCT-SVD and SchurMark recover virtually none (≤0.01%). Under 20-dB AWGN, the two non-blind baselines reach 100.00%, compared with 99.48% for our blind detector. After band-pass filtering, ECGGuard-ECC16 still recovers 96.11% of the messages, DCT-SVD 18.74%, and SchurMark none. The comparison therefore shows a trade-off between robustness to noise and robustness to time shifts, not a method that wins everywhere. Table III uses all 49,634 DS2 segments with one message seed per model, so its values differ slightly from those in Table II, which average three message seeds.

Higher SNR. Table III uses the native strength of ECGGuard (about 11 dB). Lowering α\alpha only at inference does not reach higher SNR (2.27% exact recovery at 20 dB). Models retrained with a smaller final α\alpha work near their own SNR: 75.17 ± 22.56% at 20 dB (final α=0.051\alpha= 0.051) and 98.01 ± 1.14% at 25 dB (final α=0.016\alpha= 0.016; 97.78 ± 1.35% under a +30-sample shift), with a Class-V sensitivity of 85.11% (clean reference 84.86%). At every SNR, the SNR-matched baselines decode all clean messages but virtually none under shifts. No model was reliable at 30 dB (at most 17.82%), and models do not transfer to other strengths (the α=0.016\alpha= 0.016 models recover 15.16% at 12 dB).

Watermark-Presence Detection

When separating clean from watermarked DS2 segments, the detector DD reaches an AUROC of 1.0000 (rounded to four decimals, for all three models), with an FPR of 0.000% and an FNR of 0.002% at the threshold pwm=0.5p_{\mathrm{wm}} = 0.5. The detector thus reliably tells whether a watermark is present under normal processing; because no secret key is used, this says nothing about security against deliberate forgery or removal.

Diagnostic Fidelity

Table IV(a) applies the guiding ResNet arrhythmia classifier, trained on clean DS1, to watermarked DS2 signals without retraining. Even on clean signals, this classifier rarely detects the rare classes (3.86% sensitivity for Class S and 0% for F and Q). Rare classes are known to be hard under the inter-patient protocol [3], [40], and our classifier was trained without class rebalancing, so macro-F1 and per-class sensitivity are more informative than overall accuracy. With ECGGuard, overall accuracy changes from 89.08% to 89.74%, macro-F1 from 34.13% to 33.78%, and Class-V sensitivity from 84.86% to 83.41%, while Class-S sensitivity falls from 3.86% to 1.98%. At the same SNR, the transform baselines change the diagnosis much more: Class-V sensitivity falls to 33.05% with DCT-SVD and to 69.17% with SchurMark, mostly because V beats are labeled N (65.73% and 30.69% of V beats). SchurMark even raises accuracy to 92.63% while doing so, which shows why accuracy alone is misleading. LSB changes the signal far less (SNR 86 dB) and leaves the predictions almost unchanged. Because this classifier also guides Ldiag\mathcal{L}_{\mathrm{diag}}, the comparison favors ECGGuard.

MethodTrainTestAcc.Macro-F1NSV (Δ\Delta vs. Ref.)FQ
No watermark (reference)CleanClean89.0834.1393.733.8684.860.000.00
ECGGuard (Ours)CleanWatermarked89.7433.7894.651.9883.41 (−1.45)0.000.00
LSB [11]CleanWatermarked89.0834.1393.723.8684.86 (0.00)0.000.00
DCT-SVD [15, 16]CleanWatermarked90.0128.6398.700.1133.05 (−51.81)0.260.00
SchurMark [18]CleanWatermarked92.6334.6099.000.2069.17 (−15.69)0.000.00
ConfigurationBit Acc.SNR (dB)Acc.Macro-F1NSV (Δ\Delta vs. Ref.)FQ
λdiag=0\lambda_{\mathrm{diag}}=0 (no Ldiag\mathcal{L}_{\mathrm{diag}})96.61±3.2710.3789.9731.7297.410.2749.87±2.26 (−34.99)0.830.00
λdiag=0.05\lambda_{\mathrm{diag}}=0.0594.21±6.889.8789.7633.6894.881.7280.74±2.24 (−4.10)0.030.00
λdiag=0.1\lambda_{\mathrm{diag}}=0.1 (Ours)98.62±1.6511.1389.7233.7894.641.9783.28±2.15 (−1.59)0.060.00
λdiag=0.5\lambda_{\mathrm{diag}}=0.589.55±3.2010.3189.5034.1894.223.3684.97±0.33 (+0.12)0.060.00

Table IV. TABLE IV Diagnostic fidelity on DS2 (%). (a) Classifier trained on clean DS1 and applied to watermarked DS2 without retraining, at matched SNR (except LSB). (b) Effect of the diagnostic-loss weight λdiag\lambda_{\mathrm{diag}}. (a) Comparison of watermarking methods. (b) Diagnostic-loss weight (ECGGuard, Clean→\toWatermarked). Values are means over three trained models (± SD for bit accuracy and Class-V sensitivity in (b)); parentheses in Column V show the mean percentage-point change relative to the clean reference (84.86%), computed per model. Bold in (b) marks the highest bit accuracy. Subtable (a) uses the matched setting of Table III (all 49,634 DS2 segments, one message seed per model); LSB has no strength parameter and changes the signal far less (SNR 86 dB). Subtable (b) varies only λdiag\lambda_{\mathrm{diag}} (three message seeds per model). Values closer to the reference indicate smaller diagnostic drift; higher overall accuracy or Class-N sensitivity than the reference reflects pathological Class-V beats shifting toward Class N. AAMI classes: N = normal and bundle branch block; S = supraventricular ectopic; V = ventricular ectopic; F = fusion; Q = unknown.

Independent classifier. The classifier in Table IV(a) is the same one that guides Ldiag\mathcal{L}_{\mathrm{diag}}, so testing only on it is partly circular. We therefore trained a separate 1-D ResNet with three random seeds for each of the three ECGGuard models (nine pairs) and compared Clean→Watermarked (C→W) with Clean→Clean (C→C) on DS2 with a patient-level bootstrap. Class-V sensitivity fell by 10.32 ± 10.24 pp (median 6.00 pp, largest drop 34.85 pp), compared with 33.45 ± 9.94 pp for models trained without Ldiag\mathcal{L}_{\mathrm{diag}}, and macro-F1 changed by −2.16 ± 1.64 pp; its patient-level 95% bootstrap interval included zero for eight of the nine pairs, but also for all nine pairs without Ldiag\mathcal{L}_{\mathrm{diag}}, so macro-F1 is not a sensitive measure here. Ldiag\mathcal{L}_{\mathrm{diag}} thus also protects classifiers not used in training, but much less and by an amount that depends on the classifier, so each deployed classifier should be checked separately.

Effect of the Diagnostic Loss

Table IV(b) isolates Ldiag\mathcal{L}_{\mathrm{diag}}: the four configurations differ only in λdiag\lambda_{\mathrm{diag}}. Without Ldiag\mathcal{L}_{\mathrm{diag}}, the watermark itself is reliable (96.61% bit accuracy and 99.94% soft-ECC recovery on clean segments), but Class-V sensitivity falls from 84.86% to 49.87% because 49.26% of V beats are labeled N (14.80% on clean signals). The drop of 34.99 ± 2.26 pp compares with 1.59 ± 2.15 pp at λdiag=0.1\lambda_{\mathrm{diag}}=0.1, a difference far larger than the variation across seeds. A larger weight (λdiag=0.5\lambda_{\mathrm{diag}}=0.5) leaves the diagnosis almost unchanged but lowers bit accuracy to 89.55%, and λdiag=0.05\lambda_{\mathrm{diag}}=0.05 lies between the two. Overall accuracy hides the effect: it is highest without Ldiag\mathcal{L}_{\mathrm{diag}} (89.97%) because Class N makes up 89% of DS2.

MetricUnseen subjects λdiag=0.1\lambda_{\mathrm{diag}}=0.1Unseen subjects λdiag=0\lambda_{\mathrm{diag}}=0INCART (external) λdiag=0.1\lambda_{\mathrm{diag}}=0.1INCART (external) λdiag=0\lambda_{\mathrm{diag}}=0
Clean SNR (dB)11.14±0.439.80±0.368.87±2.847.64±3.08
Bit accuracy86.06±3.6090.49±3.6896.22±4.6692.78±6.53
Exact, clean99.13±0.6298.90±1.0995.74±6.8190.27±10.99
Exact, +30 shift98.26±1.7698.64±1.2195.58±7.0389.72±11.17

Table V. TABLE V Watermark reliability beyond the random-segment protocol (%, mean ± SD over three trained models). Exact: exact 16-bit message recovery with soft ECC. Unseen subjects: subject-separated training, with 20,180 segments from 9 test subjects never used in training. INCART: 175,606 segments from 32 patients; the DS1/DS2 watermarking models are applied without retraining or recalibration and at the same embedding strength as on DS2, which gives a lower SNR (at the DS2 SNR, exact recovery is 87.15±21.63%). Diagnostic results for both protocols are given in the text.

Generalization to Unseen Subjects and an External Database

Table V shows whether the payload survives two cases that the random-segment protocol cannot cover. For the nine unseen subjects, channel-bit accuracy drops to 86.06% (98.62% on DS2), so the DS2 bit accuracy is optimistic for new patients, but soft ECC still recovers 99.13% of the 16-bit messages (98.26% under a +30-sample shift) because the errors fall mostly on the parity channels (mean error rate 27.77%, compared with 0.11% on the information channels). On INCART, the models trained on MIT-BIH, applied without retraining or recalibration, recover 95.74% of the messages (95.58% under a +30-sample shift), and presence detection keeps an AUROC of 0.9998 with an FPR of 1.48%. The same embedding strength gives a lower SNR on INCART (8.87 dB vs. 11.13 dB on DS2), that is, a relatively stronger watermark. When the strength is scaled so that the INCART SNR equals the DS2 SNR, exact recovery is 87.15 ± 21.63%, with large differences between models. The payload therefore carries over to new patients and, with lower and more model-dependent reliability, to a different database.

Diagnosis on unseen subjects and on INCART. For the unseen subjects, the classifier is retrained on the 25 training subjects, and the results show the same trend as Table IV(b), only stronger. Without Ldiag\mathcal{L}_{diag}, Class-V sensitivity falls from 94.66% to 27.61 ± 7.19%, mostly because V beats are labeled N (70.36% of V beats, compared with 5.23% on clean signals), and macro-F1 falls from 28.36% to 23.57 ± 1.54%. With λdiag=0.1\lambda_{diag} = 0.1, Class-V sensitivity falls only to 82.49 ± 1.61% and macro-F1 to 27.44 ± 1.74%. This drop of 12.17 ± 1.61 pp, much larger than the 1.59 pp on DS2, is the stricter estimate of the diagnostic cost, because the watermarking network had seen most DS2 test segments in training. INCART does not allow a comparable test: the MIT-BIH classifier already transfers poorly to clean INCART beats (Class-V sensitivity 67.35%, compared with 84.86% on clean DS2), and on watermarked INCART beats it drops to 17.10%, or to 22.09% when the embedding strength is scaled so that the INCART SNR equals the DS2 SNR. Because both this classifier and Ldiag\mathcal{L}_{diag} were fitted to MIT-BIH, diagnostic protection learned on one database does not carry over to another (Section VI-B).

Computational Cost and Visual Example

The generator GG and detector DD have 313,377 and 247,970 parameters, totaling 561,347 (2.14 MiB in FP32) with 3.67 MiB peak GPU memory during inference. For a 1,024-sample (2.84-s) segment, median runtime is 11.47 ms for embedding and 7.20 ms for extraction on one thread of an x86_64 CPU (2.97 ms and 1.27 ms on an RTX 4090 GPU). The 18.67-ms total CPU time is just 0.66% of the segment duration, far faster than real time, and soft ECC decoding adds 0.28 ms. While the model size matches wearable ECG networks [4], [5], [49], [50], timings were measured on desktop hardware rather than microcontrollers.

Figure 3 shows the first DS2 segment of record 100 in the matched setting. At this strength, the learned and transform watermarks are all visible: ECGGuard adds a small broadband ripple over the whole segment and slightly lowers the R peaks, DCT-SVD adds stronger ripples and changes the QRS amplitude, and SchurMark adds isolated spikes, also between the beats. The LSB quantizes the signal to 16 bits and replaces the least significant bit of 16 samples, which is not visible. Visual similarity of a single segment does not replace the quantitative diagnostic evaluation in § 5-E.

Clean and watermarked versions of one DS2 segment

Figure 3. Clean and watermarked versions of one DS2 segment (record 100) in the matched setting, with the SNR of each method on this segment. Gray: clean signal; blue: watermarked signal. The shaded band marks the low-amplitude interval between two QRS complexes (T wave, baseline, and P wave), complementing Table IV.

Discussion

Design Implications

Robustness to time shifts versus robustness to noise. The results show a consistent trade-off. Transform-domain methods spread each bit over a block of coefficients, which makes them robust to broadband noise and quantization, but the receiver must rebuild the same block grid. ECGGuard replaces this grid with local convolutional evidence averaged over time. It therefore tolerates shifts, filtering, and twofold resampling, but keeps a small error on clean signals and is less accurate than DCT-SVD under 20–30-dB noise, quantization, and fourfold resampling (Tables I and Table III). At higher SNR, the advantage holds only for a model trained for that SNR (§ 5-C). In remote monitoring, segment offsets and dropped packets can occur and the original signal is not available at the receiver, so blind extraction that tolerates time shifts is the more useful property.

Payload size, reliability, and choice of code. Bit accuracy alone can be misleading. The same networks that deliver a fully correct uncoded 32-bit message in 31.75%–99.69% of clean segments deliver a fully correct 16-bit message in 99.86%–100% of them when half of the channels are used for redundancy. For patient identifiers or record pointers, a short message that is always correct is more useful, so learned watermarks carrying structured data should report exact-message recovery together with the code rate. We chose the extended Hamming(8,4) code because exact ML decoding over 16 codewords is trivial; longer codes such as BCH codes [25], [27] could carry more bits at the same reliability. Packet loss behaves more like missing bits (erasures) than like random bit errors, so erasure-aware decoding or an extra erasure code across consecutive segments could help. Adding a threshold on the decoding score in (12) would also allow unreliable segments to be rejected.

Effect on diagnosis. The results do not support the claim that the watermark leaves the diagnosis unchanged. For the guiding classifier, Ldiag\mathcal{L}_{diag} keeps the loss of Class-V sensitivity small on DS2 (1.59 pp) and moderate for unseen subjects (12.17 pp), but Class-S sensitivity falls from 3.86% to 1.97% (Table IV(b)), the protection is weaker for independently trained classifiers (10.32 pp on average), and it could not be shown on INCART (§ 5-G). Supraventricular ectopic beats are mainly recognized from early timing and small P-wave changes [3], and the reference classifier already detects them poorly, so a small absolute drop is a large relative loss. The errors move mostly toward Class N because the classifier favors the majority class. In an exploratory analysis, a class-weighted evaluator that never guided training still lost Class-V sensitivity (65.5% to 58.3% with λdiag=0.1\lambda_{diag}=0.1, 35.9% without Ldiag\mathcal{L}_{diag}), with N beats then misclassified as S or F, so the imbalance decides where the errors go, not whether they occur. The residual energy was spread almost evenly over the segment for every λdiag\lambda_{diag}, so Ldiag\mathcal{L}_{diag} changes the shape and spectrum of the residual rather than moving it away from the QRS complex. Possible remedies include a class-weighted Ldiag\mathcal{L}_{diag}, a limit on residual energy near the P wave, and training on several databases. Three guiding classifiers instead of one did not meet a criterion fixed in advance: the mean and largest Class-V drops on the independent classifiers shrank (10.32 to 7.96 pp and 34.85 to 14.36 pp), but macro-F1 fell more (4.80 vs. 2.16 pp) and INCART did not improve. Because the effect differs between classifiers and databases, the effect on diagnosis should be checked for every deployed model, and review by clinicians would be needed before clinical use.

Limitations and Future Directions

Cross-patient watermark training. While our diagnostic classifier strictly follows the inter-patient DS1/DS2 split, the watermarking network was trained on randomly split segments. Segments from the same patient therefore appear in both training and test data (79.8% of the DS2 test segments were training segments), and the DS1 segments used to select π\pi and the checkpoint come from records whose other segments were used for training. The DS2 results are therefore optimistic: Ldiag\mathcal{L}_{diag} was also optimized on most DS2 test segments with the same classifier, and the windows of neighboring beats overlap. With subject-separated training (§ 5-G), bit accuracy drops by 12.6 pp and the Class-V sensitivity drop grows from 1.59 to 12.17 pp, while soft ECC keeps message recovery near 99%. That test set has only nine subjects.

Dataset scope and extreme channel loss. Our evaluation focuses on fixed-length, single-lead segments from the MIT-BIH database, with one external test on INCART. Extending ECGGuard to multi-lead systems, diverse sampling rates, and wearable recordings with heavy motion artifacts is a natural direction for future work. Furthermore, while our frame-level ECC handles moderate data drops well, severe 50% packet loss reduces full-message recovery to 33.01% (21.40%–49.05% across models), and fourfold down- and up-sampling lowers bit accuracy to 58.16%, close to chance. Overcoming such extreme link failures will require pairing ECGGuard with inter-segment erasure coding or retransmission protocols. Adding resampling to the distortion layer is a possible remedy for the second weakness.

Cryptographic security. This study focuses on transmission robustness against unintentional channel distortions rather than adversarial security. For security-critical IoMT deployments, ECGGuard can be combined with encryption or digital signatures applied prior to ECC encoding to keep the message confidential and to detect forged messages, but neither prevents removal of the watermark.

Diagnostic generalization and edge deployment. The λdiag\lambda_{diag} sweep in Table IV(b) isolates Ldiag\mathcal{L}_{diag} for one classifier architecture and one database. Its protection is partial for other classifiers and could not be shown on INCART, where the MIT-BIH classifier already transfers poorly; training the guiding classifier on several databases and evaluating with one trained on the target database are the next steps. Classes S, F, and Q are detected too poorly to support conclusions, and each model works only near the SNR it was trained for. Run time was measured only on desktop hardware, and deployment on wearable microcontrollers was not tested.

Conclusion

This article presented ECGGuard, a compact, quantization-free deep watermarking framework for single-lead ECG. Combining frame-level convolutions, a diagnostic loss, and soft-decision Hamming decoding, it jointly addresses time shifts, diagnostic consistency, and full-message recovery. Experiments on MIT-BIH, with an external test on INCART, yield two key findings. First, frame-level extraction resists time shifts, which break block-transform methods, and also tolerates filtering, twofold resampling, and sample deletion. Second, while bit accuracy alone is insufficient, soft ECC decoding recovers full 16-bit messages in 99.95% of clean segments and over 96% under shifts, 10% deletion, or 10% packet loss, and in 99.13% of segments from subjects unseen in training. The diagnostic loss limits the drop in ventricular-beat sensitivity for the guiding classifier, but only partly for other classifiers and not across databases. Thus, physiological watermarking should prioritize exact-message recovery and diagnostic consistency on unseen patients over waveform fidelity alone. Future work will extend ECGGuard to multi-lead signals, training on several databases, and cryptographic provenance for IoMT monitoring. Code will be released upon publication.

References

  1. [1]M. M. Ozcelik, I. Kok, and S. Ozdemir, “A survey on Internet of Medical Things (IoMT): Enabling technologies, security and explainability issues, challenges, and future directions,” Expert Syst., vol. 42, no. 5, p. e70010, 2025.DOI
  2. [2]A. Y. Hannun, P. Rajpurkar, M. Haghpanahi, G. H. Tison, C. Bourn, M. P. Turakhia, and A. Y. Ng, “Cardiologist-level arrhythmia detection and classification in ambulatory electrocardiograms using a deep neural network,” Nat. Med., vol. 25, no. 1, pp. 65–69, 2019.DOI
  3. [3]E. J. da S. Luz, W. R. Schwartz, G. Câmara-Chávez, and D. Menotti, “ECG-based heartbeat classification for arrhythmia detection: A survey,” Comput. Methods Programs Biomed., vol. 127, pp. 144–164, 2016.
  4. [4]X. Mao, M. Wang, J. Xu, J. Wang, H. Zheng, and S. Xu, “An ultra-low power architecture for wearable ECG patches with real-time myocardial infarction detection,” IEEE Trans. Consum. Electron., vol. 72, no. 2, pp. 4580–4587, 2026.DOI
  5. [5]T.-M. Chen, Y.-H. Tsai, H.-H. Tseng, K.-C. Liu, J.-Y. Chen, C.-H. Huang, G.-Y. Li, C.-Y. Shen, and Y. Tsao, “SREC-G: ECG signal super-resolution framework for portable/wearable devices in cardiac arrhythmias classification,” IEEE Trans. Consum. Electron., vol. 69, no. 3, pp. 250–260, 2023.DOI
  6. [6]S. A. Soleymani, S. Goudarzi, M. H. Anisi, A. Jindal, N. Kama, and S. A. Ismail, “A privacy-preserving authentication scheme for real-time medical monitoring systems,” IEEE J. Biomed. Health Inform., vol. 27, no. 5, pp. 2314–2322, 2023.
  7. [7]W. Liu, F. Zhao, L. Nkenyereye, S. Rani, K. Li, and J. Lv, “XAI driven intelligent IoMT secure data management framework,” IEEE J. Biomed. Health Inform., vol. 30, no. 2, pp. 935–946, 2026.
  8. [8]J. Rani and A. Anand, “A review on advancement in watermarking techniques for biomedical data in e-Healthcare applications,” Biomed. Signal Process. Control, vol. 112, p. 108521, 2026.DOI
  9. [9]P. V. B. Bayari, N. Tomar, G. Bhatnagar, and C. Chattopadhyay, “Watermarking protocol inspired kidney stone segmentation in IoMT,” IEEE J. Biomed. Health Inform., vol. 30, no. 2, pp. 828–838, 2026.DOI
  10. [10]W. Min, A. Laouid, M. Hammoudeh, B. Ferik, and F. Azzedin, “Protecting consumer healthcare imaging data from AI-tampering via blind reversible watermarking,” IEEE Trans. Consum. Electron., vol. 72, no. 3, pp. 7348–7361, 2026.DOI
  11. [11]B. Halder, S. Mitra, S. S. Bose, and N. Mishra, “Patient information implantation and reclamation from compressed ECG signal by LSB watermarking technique,” in Proc. Int. Conf. Ind. Eng. Sci. Appl. (IESA), 2014, pp. 52–57.
  12. [12]S. Bhalerao, I. A. Ansari, and A. Kumar, “Reversible ECG watermarking for ownership detection, tamper localization, and recovery,” Circuits Syst. Signal Process., vol. 41, no. 9, pp. 5134–5159, 2022.DOI
  13. [13]A. Ibaida and I. Khalil, “Wavelet-based ECG steganography for protecting patient confidential information in point-of-care systems,” IEEE Trans. Biomed. Eng., vol. 60, no. 12, pp. 3322–3330, 2013.DOI
  14. [14]R. Hamami, N. Zermi, L. Bouchir, A. Khalidi, M. R. Kafi, A. K. Sahu, and N. Mimoune, “Securing patient-specific ECG data in telemedicine through adaptive wavelet-based watermarking,” Intell.-Based Med., vol. 13, p. 100357, 2026.DOI
  15. [15]S. Edward Jero, P. Ramu, and S. Ramakrishnan, “Discrete wavelet transform and singular value decomposition based ECG steganography for secured patient information transmission,” J. Med. Syst., vol. 38, no. 10, p. 132, 2014.DOI
  16. [16]A. Anand and A. K. Singh, “An improved DWT-SVD domain watermarking for medical information security,” Comput. Commun., vol. 152, pp. 72–80, 2020.DOI
  17. [17]L. M. Goyal, M. Mittal, R. Kaushik, A. Verma, I. Kaur, S. Roy, and T.-H. Kim, “Improved ECG watermarking technique using curvelet transform,” Sensors, vol. 20, no. 10, p. 2941, 2020.DOI
  18. [18]A. Tiwari, D. Awasthi, and V. K. Srivastava, “SchurMark: Robust and secure ECG watermarking in Schur domain for IoMT,” Multimedia Tools Appl., vol. 85, no. 4, p. 331, 2026.DOI
  19. [19]S. Voloshynovskyy, S. Pereira, T. Pun, J. J. Eggers, and J. K. Su, “Attacks on digital watermarks: Classification, estimation based attacks, and benchmarks,” IEEE Commun. Mag., vol. 39, no. 8, pp. 118–126, 2001.
  20. [20]X. Han, Y. Hu, L. Foschini, L. Chinitz, L. Jankelson, and R. Ranganath, “Deep learning models for electrocardiograms are susceptible to adversarial attack,” Nat. Med., vol. 26, no. 3, pp. 360–363, 2020.DOI
  21. [21]S. G. Finlayson, J. D. Bowers, J. Ito, J. L. Zittrain, A. L. Beam, and I. S. Kohane, “Adversarial attacks on medical machine learning,” Science, vol. 363, no. 6433, pp. 1287–1289, 2019.DOI
  22. [22]C.-Y. Hsu, C.-Y. Chang, Y.-C. Chen, J. Wu, and S.-T. Chen, “ECG sensor design assessment with variational autoencoder-based digital watermarking,” Sensors, vol. 25, no. 7, p. 2321, 2025.DOI
  23. [23]L. Zhang, W. Zhou, T. Ding, C. Xiao, J. Wang, D. Ding, and J. Lei, “Robust EEG watermark via dual-stream frequency–time attention network against signal processing attacks,” Electronics, vol. 15, no. 13, p. 2864, 2026.DOI
  24. [24]R. W. Hamming, “Error detecting and error correcting codes,” Bell Syst. Tech. J., vol. 29, no. 2, pp. 147–160, 1950.DOI
  25. [25]S. Lin and D. J. Costello, Error Control Coding: Fundamentals and Applications, 2nd ed. Upper Saddle River, NJ, USA: Pearson Prentice Hall, 2004.
  26. [26]J. Zhu, R. Kaplan, J. Johnson, and L. Fei-Fei, “HiDDeN: Hiding data with deep networks,” in Proc. Eur. Conf. Comput. Vis. (ECCV), 2018, pp. 682–697.arxiv.org/abs/1807.09937
  27. [27]M. Tancik, B. Mildenhall, and R. Ng, “StegaStamp: Invisible hyperlinks in physical photographs,” in Proc. IEEE/CVF Conf. Comput. Vis. Pattern Recognit. (CVPR), 2020, pp. 2117–2126.arxiv.org/abs/1904.05343
  28. [28]X. Luo, R. Zhan, H. Chang, F. Yang, and P. Milanfar, “Distortion agnostic deep watermarking,” in Proc. IEEE/CVF Conf. Comput. Vis. Pattern Recognit. (CVPR), 2020, pp. 13 548–13 557.arxiv.org/abs/2001.04580
  29. [29]Y. Zhang, J. Ni, W. Al Malwi, F. Asiri, J. Ahmad, and D. Jiang, “A practical distortion simulator for screen-shooting resilient image watermarking in consumer electronic applications,” IEEE Trans. Consum. Electron., vol. 71, no. 2, pp. 5069–5078, 2025.DOI
  30. [30]M. Ahmadi, A. Norouzi, N. Karimi, S. Samavi, and A. Emami, “ReD-Mark: Framework for residual diffusion watermarking based on deep networks,” Expert Syst. Appl., vol. 146, p. 113157, 2020.
  31. [31]P. Fernandez, G. Couairon, H. Jégou, M. Douze, and T. Furon, “The stable signature: Rooting watermarks in latent diffusion models,” in Proc. IEEE/CVF Int. Conf. Comput. Vis. (ICCV), 2023, pp. 22 466–22 477.arxiv.org/abs/2303.15435
  32. [32]G. Chen, Y. Wu, S. Liu, T. Liu, X. Du, and F. Wei, “WavMark: Watermarking for audio generation,” arXiv preprint arXiv:2308.12770, 2023.arxiv.org/abs/2308.12770
  33. [33]C. Liu, J. Zhang, T. Zhang, X. Yang, W. Zhang, and N. Yu, “Detecting voice cloning attacks via timbre watermarking,” in Proc. Netw. Distrib. Syst. Secur. Symp. (NDSS), 2024.arxiv.org/abs/2312.03410
  34. [34]R. San Roman, P. Fernandez, H. Elsahar, A. Défossez, T. Furon, and T. Tran, “Proactive detection of voice cloning with localized watermarking,” in Proc. Int. Conf. Mach. Learn. (ICML), vol. 235, 2024, pp. 43 180–43 196.
  35. [35]S. S. Xu, M.-W. Mak, and C.-C. Cheung, “Towards end-to-end ECG classification with raw signal extraction and deep neural networks,” IEEE J. Biomed. Health Inform., vol. 23, no. 4, pp. 1574–1584, 2019.DOI
  36. [36]K. He, X. Zhang, S. Ren, and J. Sun, “Deep residual learning for image recognition,” in Proc. IEEE Conf. Comput. Vis. Pattern Recognit. (CVPR), 2016, pp. 770–778.arxiv.org/abs/1512.03385
  37. [37]M. Kachuee, S. Fazeli, and M. Sarradfazed, “ECG heartbeat classification: A deep transferable representation,” in Proc. IEEE Int. Conf. Healthcare Inform. (ICHI), 2018, pp. 443–444.DOI
  38. [38]T. Mehari, A. Sundar, A. Bošnjaković, P. Harris, S. E. Williams, A. Loewe, O. Doessel, C. Nagel, N. Strodthoff, and P. J. Aston, “ECG feature importance rankings: Cardiologists vs. algorithms,” IEEE J. Biomed. Health Inform., vol. 28, no. 4, pp. 2014–2024, 2024.
  39. [39]A. I. Newaz, N. I. Haque, A. K. Sikder, M. A. Rahman, and A. S. Ulul-agac, “Adversarial attacks to machine learning-based smart healthcare systems,” in Proc. IEEE Global Commun. Conf. (GLOBECOM), 2020, pp. 1–6.arxiv.org/abs/2010.03671
  40. [40]P. de Chazal, M. O’Dwyer, and R. B. Reilly, “Automatic classification of heartbeats using ECG morphology and heartbeat interval features,” IEEE Trans. Biomed. Eng., vol. 51, no. 7, pp. 1196–1206, 2004.pubmed.ncbi.nlm.nih.gov/15248536
  41. [41]V. Mondéjar-Guerra, J. Novo, J. Rouco, M. G. Penedo, and M. Ortega, “Heartbeat classification focusing temporal and morphological information of ECGs via ensemble of classifiers,” Biomed. Signal Process. Control, vol. 47, pp. 41–48, 2019.
  42. [42]D. Chase, “A class of algorithms for decoding block codes with channel measurement information,” IEEE Trans. Inf. Theory, vol. 18, no. 1, pp. 170–182, 1972.
  43. [43]S. Schwär and M. Müller, “Multi-scale spectral loss revisited,” IEEE Signal Process. Lett., vol. 30, pp. 1712–1716, 2023.
  44. [44]I. Loshchilov and F. Hutter, “SGDR: Stochastic gradient descent with warm restarts,” in Proc. Int. Conf. Learn. Represent. (ICLR), 2017.arxiv.org/abs/1608.03983
  45. [45]M. Heusel, H. Ramsauer, T. Unterthiner, B. Nessler, and S. Hochreiter, “GANs trained by a two time-scale update rule converge to a local Nash equilibrium,” in Adv. Neural Inf. Process. Syst. (NeurIPS), vol. 30, 2017, pp. 6626–6637.
  46. [46]G. B. Moody and R. G. Mark, “The impact of the MIT-BIH arrhythmia database,” IEEE Eng. Med. Biol. Mag., vol. 20, no. 3, pp. 45–50, 2001.pubmed.ncbi.nlm.nih.gov/11446209
  47. [47]A. L. Goldberger, L. A. N. Amaral, L. Glass, J. M. Hausdorff, P. C. Ivanov, R. G. Mark, J. E. Mietus, G. B. Moody, C.-K. Peng, and H. E. Stanley, “PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals,” Circulation, vol. 101, no. 23, pp. e215–e220, 2000.
  48. [48]V. Tihonenko, A. Khaustov, S. Ivanov, and A. Rivin, “St.-Petersburg Institute of Cardiological Technics 12-lead Arrhythmia Database,” PhysioNet, doi: 10.13026/C2V88N, 2007.
  49. [49]S. Rahman, S. Pal, J. Yearwood, and C. Karmakar, “Analysing performances of DL-based ECG noise classification models deployed in memory-constraint IoT-enabled devices,” IEEE Trans. Consum. Electron., vol. 70, no. 1, pp. 704–714, 2024.DOI
  50. [50]C. Liu, J. Liu, and D. Wang, “Energy-efficient health monitoring in smart devices: Deep learning-based technique for wearable ECG systems,” IEEE Trans. Consum. Electron., vol. 71, no. 2, pp. 4736–4743, 2025.DOI

Paper details

vlnc:W_26kxtpbz
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 2

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Engineering

Not recorded for this paper

View statement
Looking for related papers…
Contents