Half-Life Measurements of 110^{110}Sn, 113^{113}Sn, 117m^{117\mathrm{m}}Sn, and 123m^{123\mathrm{m}}Sn Produced via Photon Activation of Natural Tin

Abstract

We report independent determinations of the ground-state half-lives of 110^{110}Sn, 113^{113}Sn, and the isomeric states 117m^{117\mathrm{m}}Sn (Jπ=11/2−^π = 11/2^{-}) and 123m^{123\mathrm{m}}Sn (Jπ=3/2+^π = 3/2^{+}), produced via photon activation of natural tin using a TT-300HE Rhodotron accelerator. The activated samples were monitored over several months using a high-purity germanium (HPGe) detector. Time-dependent γγ-ray spectra were analyzed using Gaussian peak fitting for the \SI{280.49}{keV}, \SI{391.697}{keV}, \SI{158.56}{keV}, and \SI{160.34}{keV} transitions, yielding half-lives of \SI{4.165(25)}{h} for 110^{110}Sn, \SI{116.08(94)}{d} for 113^{113}Sn, \SI{13.95(1)}{d} for 117m^{117\mathrm{m}}Sn, and \SI{39.95(12)}{min} for 123m^{123\mathrm{m}}Sn. Agreement with Nuclear Data Sheets (NDS) recommended values is generally observed for 110^{110}Sn, 113^{113}Sn, and 123m^{123\mathrm{m}}Sn, with deviations consistent within combined uncertainties when quantified using standardized differences (z-scores). In contrast, 117m^{117\mathrm{m}}Sn exhibits a statistically significant deviation from the evaluated value of \SI{13.76(4)}{d}, with a z-score indicating a discrepancy well beyond expected statistical fluctuations. This result suggests a systematic difference warranting further investigation, with potential implications for applications relying on precise decay data, including calibration, dosimetry, and astrophysical modeling.

Introduction

Precise radionuclide half-lives are fundamental to applied and basic nuclear science. They underpin normalization of activation measurements used to constrain astrophysical reaction rates, detector efficiency calibration, decay corrections in environmental and medical assays, and nuclear data. In this work, we revisit four tin nuclides: 110Sn^{110}\mathrm{Sn} (astrophysical p-process benchmarks), 113Sn^{113}\mathrm{Sn} (a calibration standard), 117mSn^{117\mathrm{m}}\mathrm{Sn} (nuclear medicine dosimetry), and 123mSn^{123\mathrm{m}}\mathrm{Sn} (nuclear data). All were produced via photon activation of natural tin and monitored by long-term HPGe spectrometry, providing an independent cross-check of evaluated decay data.

110Sn^{110}\mathrm{Sn}: Astrophysical Significance in the p-Process

Precision half-life measurements for neutron-deficient isotopes near the Z=50Z = 50, N=50N = 50 shell closures are essential for modeling the astrophysical p-process, which synthesizes rare proton-rich nuclei not produced via the s- or r-processes Rauscher and Thielemann [18]; Arnould and Goriely [1]. The reaction network in this mass region is typically constrained by Hauser–Feshbach statistical model calculations, whose reliability hinges on inputs such as optical model potentials, level densities, and γ\gamma-strength functions Goriely [10]. Because experimental cross sections at stellar energies (the Gamow window) are sparse, activation measurements and decay data—including half-lives—are used to normalize and validate rate predictions Sauter and Kӓppeler [21]; Bork et al. [4]; Chloupek et al. [7]; Gyürky et al. [12]. For 110Sn^{110}\mathrm{Sn}, accurate half-life information improves the fidelity of cross-section measurements for reactions such as 106Cd(α,γ)110Sn^{106}\mathrm{Cd}(\alpha,\gamma)^{110}\mathrm{Sn}, which probes the light p-nuclei production pathway up to 113In^{113}\mathrm{In} in the Z=50Z = 50 region Gyürky et al. [12]. Independent half-life determinations using distinct production and counting methodologies therefore provide critical cross-checks on evaluated data and help reduce systematic uncertainties in nuclear astrophysics.

113Sn^{113}\mathrm{Sn}: Calibration and Standards

The ground state of 113Sn^{113}\mathrm{Sn} decays by electron capture to 113In^{113}\mathrm{In}, emitting well-characterized γ\gamma rays widely used for HPGe spectrometer calibration and tracer studies. Its half-life has been measured repeatedly over decades. Early systematic programs at Oak Ridge National Laboratory employed NaI(Tl), proportional counters, and ionization chambers, establishing values near ~115 d Emery [9]. Independent γ\gamma-spectrometric measurements with radiochemically purified samples corroborated this range Lagoutine et al. [15]. Large inter-comparison efforts coordinated by the International Atomic Energy Agency (IAEA) remeasured numerous γ\gamma emitters (including 113Sn^{113}\mathrm{Sn}) with calibrated 4π4\pi ionization chambers, yielding high-precision decay constants Houtermans et al. [14]. Subsequent re-examinations at national standards laboratories incorporated improved detector stability, impurity analyses, and reference-source corrections Hoppes and Schima [13]; Unterweger et al. [23]. These studies support the currently recommended value T1/2=(115.09±0.03)T_{1/2} = (115.09 \pm0.03) d in the Nuclear Data Sheets (NDS) evaluation for A=113A = 113 Blachot [3]. Because 113^{113}Sn underlies detector calibration and inter-laboratory consistency, new independent determinations using distinct production routes and high-resolution gamma-ray spectrometry remain valuable.

117m^{117m}Sn: Nuclear Medicine and Dosimetry

The isomeric state 117m^{117m}Sn (Jπ=11/2−J^\pi= 11/2^-) combines a monoenergetic 159 keV photon suitable for Single-Photon Emission Computed Tomography (SPECT) imaging with 127–155 keV conversion electrons for localized therapy. Its decay data are comprehensively evaluated in the NDS for A=117A = 117 Blachot [2], and its medical applications have been explored in modern radiopharmaceutical reviews Boschi et al. [5]. Its ∼\sim14-day half-life enables distribution and radiopharmaceutical synthesis, including SnCl2_2 and DOTA-based chelates for bone metastasis treatment. Traditional production routes employ neutron or proton reactions on tin and antimony, often yielding low specific activity or complex target chemistry [16, 22]. Photonuclear production via 118^{118}Sn(γ\gamma,n)117m^{117m}Sn using modern electron accelerators offers a clean and scalable alternative Utsunomiya et al. [24]. Accurate half-life data for 117m^{117m}Sn are critical because the NDS recommends T1/2=(13.76±0.04)T_{1/2} = (13.76 \pm0.04) d Blachot [2], and even small deviations from this value can propagate into decay-correction protocols, patient dose planning, and quantitative imaging. Such discrepancies directly affect absorbed dose estimates and therapeutic efficacy, making high-precision measurements essential for reliable nuclear medicine applications.

123m^{123m}Sn: Nuclear Data Evaluations

The isomeric state 123m^{123m}Sn (Jπ=3/2+J^\pi= 3/2^+) has a recommended half-life of T1/2=(40.06±0.02)T_{1/2} = (40.06 \pm0.02) min according to the NDS evaluation for A=123A = 123 Chen [6]. This isomer plays a role in nuclear data libraries because its decay characteristics are used in activation analysis, decay heat calculations, and modeling of photonuclear reaction chains. Even small deviations from the evaluated half-life can propagate into decay-correction factors and impact the accuracy of cross-section measurements and applied nuclear science calculations.

Experimental Method

Activation

A 0.6186 g high-purity natural tin target, composed of 99.3 % Sn with a 0.7 % Cu impurity fraction, was irradiated downstream of a 6 mm-thick tantalum bremsstrahlung converter. The irradiation was performed using a TT-300HE rhodotron delivering 40 MeV electrons at a beam current of 1 μ\muA, with a nominal beam spot diameter of 20 mm. The target consists of Ta plates, with water channels flowing between the plates as well as in front and back of the first and last plates. The irradiation geometry and particle transport are illustrated in Figure 1, where bremsstrahlung photons (yellow tracks) and electrons (red tracks) are shown interacting with the converter and target.

Image not extracted

Figure 1. PHITS Sato et al. (2024) simulation of the irradiation setup. The plate-based tantalum converter (blue disks) is cooled by water flowing between the plates (transparent). The tin target is positioned just beyond the converter window (not shown). Yellow tracks represent bremsstrahlung photons, while red tracks correspond to electrons traveling from left to right.

The normalized photon flux distribution at the target location is shown in Figure 2. This total energy-integrated photon flux map corresponds to a bremsstrahlung photon spectrum with 40 MeV end-point energy. To obtain the absolute flux, the color scale must be multiplied by the electron rate for 1 μ\muA beam current (6.24 ×1012\times10^{12} e−^-/s). The black square in Figure 2 indicates the tin target position. The irradiation time was 10 s to minimize the buildup of potential interferences and dead-time during the counting of short-lived nuclides such as 123m^{123m}Sn, while producing sufficient 113^{113}Sn and 117m^{117m}Sn activities for long-term counting.

Image not extracted

Figure 2. PHITS Sato et al. (2024) simulation results for a 40 MeV electron beam (directed from left to right along the zz-axis) with a 10 mm diameter spot. The left panel shows the normalized total photon flux per incident electron. The first tantalum converter plate, oriented perpendicular to the beam direction, is located at z=0z = 0 cm. Absolute photon flux can be obtained by multiplying the color scale by the electron rate corresponding to 1 μ\muA (6.24×10126.24 \times10^{12} e−^{-}/s). The black rectangle denotes the location of the tin target. The right panel shows the bremsstrahlung photon energy flux at the mid-plane of the target, per incident source electron.

In addition, a second irradiation was performed as part of a broader test to measure cross sections at lower beam energy. For this, a tin target (0.9526 g) was placed behind a single 3 mm tungsten plate (non-cooled) and irradiated under identical conditions of beam current (1 μ\muA) and irradiation time (20 s), but with an electron end-point energy of 36 MeV. After activation, the target was moved for extended counting with 180 s live-time intervals over more than one day to enable a precise determination of the 110^{110}Sn half-life. Only the 110^{110}Sn data originate from this lower-energy irradiation; all other isotopes (113^{113}Sn, 117m^{117m}Sn, and 123m^{123m}Sn) were measured from the first irradiation using the 6 mm Ta converter at 40 MeV.

γ\gamma-Spectral Processing and Calibration

All spectra were parsed to extract run start times, live and real time, and channel-wise counts. For each spectrum, candidate peaks corresponding to the selected γ\gamma lines (EiE_i) were located and fitted.

Energy, Resolution and Efficiency Calibrations. To ensure accurate identification of γ\gamma-ray lines and assess detector performance, energy, resolution, and efficiency calibrations were performed using standard reference peaks from multiple calibration sources.

Energy Calibration The energy calibration was established by fitting known (Ei,μi)(E_i,\mu_i) pairs, where EiE_i denotes the γ\gamma energy and μi\mu_i the corresponding channel centroid. The calibration function is expressed as:

μ=mμE+cμ,(1)\mu= m_\mu E + c_\mu, \tag*{(1)}

where mμ=(3.994 44±0.000 72)m_\mu= (3.994\,44 \pm0.000\,72) channel/keV and cμ=(−1.905±0.383)c_\mu= (-1.905 \pm0.383) channel represent the gain and offset, respectively. The linear model was found to be adequate, as confirmed by the residuals shown in Figure 3. This calibration was used solely for peak identification and verification of assignments; all quantitative analyses (e.g., peak area extraction) were performed in the original channel domain without transforming spectra into energy space.

Image not extracted

Figure 3. Energy calibration curve obtained by fitting channel centroids (blue markers; error bars are present but too small to be visible) to known γ\gamma-ray energies from multiple calibration sources. The linear fit (red line) shows excellent agreement, and the residuals in the lower panel confirm that a first-order polynomial is sufficient for the energy scale. The blue shaded region represents the ±3σ\pm3\sigma confidence band for the residuals. A quadratic fit (dashed green line) was also tested; however, its E2E^2 coefficient (−2.773×10−7±1.349×10−6-2.773 \times10^{-7} \pm1.349 \times10^{-6}) is negligible and comparable to its uncertainty, so it was not adopted.

Resolution Calibration The detector resolution, expressed as the Full Width at Half Maximum (FWHM), was derived from the fitted Gaussian standard deviation σ\sigma using

FWHM = 2.355 σ\sigma. The dependence of σ\sigma on energy was found to be linear:

σ(μ)=a+bE,(2)\sigma(\mu) = a + b E, \tag*{(2)}

where a=(1.6297±0.0303)a = (1.6297 \pm0.0303) channel and b=(0.002 848±0.000 044)b = (0.002\,848 \pm0.000\,044) channel/keV. This trend reflects contributions from electronic noise (constant term) and statistical fluctuations (energy-dependent term). The calibration curve and fitted function are shown in Figure 4, which also confirms the adequacy of the linear model across the energy range considered.

Image not extracted

Figure 4. Resolution calibration curve showing the measured standard deviation, σ\sigma, as a function of γ\gamma energy.

Efficiency calibration

Although absolute efficiency is not required for the half-life determination, which relies solely on relative activity ratios, an efficiency calibration was nevertheless performed to ensure completeness and internal consistency in all activity calculations.

The calibration measurements were acquired using a 229Th{}^{229}\mathrm{Th} calibration disk source that had the same radius as the activated targets and was placed at the same location of target counting. As shown in Figure 5, all calibration points lie within ±3σ\pm3\sigma of the fitted curve, confirming the consistent detector response across the energy range.

Image not extracted

Figure 5. Efficiency calibration curve obtained by fitting the empirical function to measured full-energy peak efficiencies from a 229Th{}^{229}\mathrm{Th} disk source. The top panel shows the data with the fitted function, while the bottom panel presents standardized residuals with a shaded ±3σ\pm3\sigma band. The fit quality is characterized by a chi-square of χ2=13.74\chi^2 = 13.74 with NDF = 5.

The full-energy peak efficiency was modeled using the empirical function:

ϵ(E)=(1−Ae−BE)(Ce−DE+Fe−GE),(3)\epsilon(E) = \left(1 - A e^{-B E}\right)\left(C e^{-D E} + F e^{-G E}\right), \tag*{(3)}

where EE is the photon energy in keV. The best-fit parameters are the following:

A=3.259722±0.389687,A = 3.259722 \pm0.389687,
B=3.013335×10−2±3.018147×10−3 [keV−1],B = 3.013335 \times10^{-2} \pm3.018147 \times10^{-3}\ [\mathrm{keV}^{-1}],
C=1.246222×10−3±2.971436×10−4,C = 1.246222 \times10^{-3} \pm2.971436 \times10^{-4},
D=1.279700×10−3±2.979005×10−4 [keV−1],D = 1.279700 \times10^{-3} \pm2.979005 \times10^{-4}\ [\mathrm{keV}^{-1}],
F=6.943779×10−3±6.426730×10−4,F = 6.943779 \times10^{-3} \pm6.426730 \times10^{-4},
G=7.275769×10−3±8.709378×10−4 [keV−1].G = 7.275769 \times10^{-3} \pm8.709378 \times10^{-4}\ [\mathrm{keV}^{-1}].

Overview of Spectral Evolution

Figure 6 shows three fully γ\gamma spectra collected at different times after End Of Bombardment (EOB): 1 hour (red), 5 hours (blue), and 50 hours (green). Counting times were 3 minutes, 20 minutes, and 60 minutes, respectively. The evolution illustrates the decay of short-lived isotopes and the persistence of longer-lived species such as 117mSn{}^{117}\mathrm{m}\mathrm{Sn} and 113Sn{}^{113}\mathrm{Sn}. Major isotopes are labeled on the plot.

Image not extracted

Figure 6. Full γ\gamma spectra collected at 1 hour (red), 5 hours (blue), and 50 hours (green) post-irradiation. Counting times were 3, 20, and 60 minutes, respectively. Isotopes contributing major peaks are labeled.

Isotope-Specific Peak Models

110Sn{}^{110}\mathrm{Sn} (280.49 keV): Gaussian with two-component tail and piecewise background. The 110Sn{}^{110}\mathrm{Sn} line exhibited low-energy tailing and a background slope change across the centroid. We modeled it as a mixture of two Exponentially Modified Gaussians (EMGs) sharing the same Gaussian width, plus a piecewise linear background:

f110(E)=η EMG(E;C,μ,σ,τ1)+(1−η) EMG(E;C,μ,σ,τ2)+{b1E+m1,E<μ,b2E+m2,E≥μ.(4)\begin{aligned} f_{110}(E) ={}& \eta\,\mathrm{EMG}(E; C,\mu,\sigma,\tau_1) + (1-\eta)\,\mathrm{EMG}(E; C,\mu,\sigma,\tau_2) \\ &+ \begin{cases} b_1 E + m_1, & E < \mu,\\ b_2 E + m_2, & E \ge\mu. \end{cases} \tag*{(4)} \end{aligned}

where η\eta is the mixture weight, CC is the net area under the peak with μ\mu channels as the peak centroid, σ\sigma the peak width, τ1,2\tau_{1,2} the tail parameters, and bb, cc the background terms. Centroid, width, tail parameters, and η\eta were fixed.

The EMG function is defined as the convolution of a Gaussian with an exponential decay:

EMG⁡(E;C,μ,σ,τ)=C2τexp⁡(E−μτ+σ22τ2)×erfc⁡(12(E−μσ+στ))(5)\operatorname{EMG}(E; C,\mu,\sigma,\tau) = \frac{C}{2\tau}\exp\left(\frac{E-\mu}{\tau}+\frac{\sigma^2}{2\tau^2}\right)\times\operatorname{erfc}\left(\frac{1}{\sqrt{2}}\left(\frac{E-\mu}{\sigma}+\frac{\sigma}{\tau}\right)\right) \tag*{(5)}

The complementary error function erfc⁡(x)\operatorname{erfc}(x) accounts for the asymmetric tailing toward lower energies.

Figure 7 presents 20 sequential spectra fitted using the tail-corrected Gaussian model. The panels are arranged such that the sequence progresses from the top-left panel to the bottom-right, moving across each row from left to right. This layout reflects the temporal evolution of the collected spectra, with each subsequent panel corresponding to a later acquisition time. The dominant peak at channel μ=1118.38±0.11\mu= 1118.38 \pm0.11 represents the (280.49±0.11)(280.49 \pm0.11) keV transition of 110Sn{}^{110}\mathrm{Sn}.

Image not extracted

Figure 7. Twenty sequential γ\gamma-ray spectra for 110Sn{}^{110}\mathrm{Sn}, recorded between 6 h 8 min and 7 h 14 min post-irradiation. The panels are arranged to reflect the temporal evolution of the spectra, progressing from the top-left to the bottom-right across rows. The dominant peak at channel 1118.38 corresponds to the 280.49 keV transition of 110Sn{}^{110}\mathrm{Sn}. Each spectrum was acquired over a 180 s live counting interval. The detector dead-time for the fitted data is below 0.8%. Spectra were fitted using a Gaussian function with a two-component tail and a piecewise background model. Detailed fitting parameters are visible when zooming into the PDF version.

113Sn{}^{113}\mathrm{Sn} (391.697 keV): single-Gaussian model. The 113Sn{}^{113}\mathrm{Sn} ground-state transition emits a photon with energy 391.697 keV and was well isolated and fitted with a single Gaussian plus linear background:

f113(E)=Cσ2πexp⁡[−(E−μ)22σ2]+bE+c,(6)f_{113}(E) = \frac{C}{\sigma\sqrt{2\pi}}\exp\left[-\frac{(E-\mu)^2}{2\sigma^2}\right]+bE+c, \tag*{(6)}

where CC is the net area under the peak, σ\sigma the peak width, and bb, cc the background terms.

117mSn{}^{117m}\mathrm{Sn} (158.56 keV), and 123mSn{}^{123m}\mathrm{Sn} (160.2 keV): triple-Gaussian with piecewise linear background. Figure 8 shows sequential spectra collected between 5 and 15.5 hours post-irradiation, illustrating the triple-Gaussian fit applied to the 158.56 keV region. The middle peak corresponds to 117mSn{}^{117m}\mathrm{Sn} (158.56 keV, intensity 86.4%, T1/2≈14T_{1/2} \approx14 d), while the rightmost peak originates from 123mSn{}^{123m}\mathrm{Sn} (160.34 keV, intensity 85.69%, T1/2≈40.06T_{1/2} \approx40.06 min). The lower energy peak located at peak centroid channel number 621.955 (156.2 keV, intensity 2.11% from 117mSn{}^{117m}\mathrm{Sn}) contributes a minor but noticeable component in the spectra.

Image not extracted

Figure 8. Sequential spectra for 117Sn{}^{117}\mathrm{Sn} between 5–15.5 hours (top-left to bottom-right panels) post-irradiation, fitted with a triple-Gaussian model. The main peak at channel (peak centroid) 631.663 corresponds to 158.56 keV (117Sn{}^{117}\mathrm{Sn}), flanked by peaks at channels 621.955 (156.2 keV) and 638.784 (160.34 keV), from 117mSn{}^{117m}\mathrm{Sn} and 123mSn{}^{123m}\mathrm{Sn}, respectively.

As shown in figure 8, the 117mSn{}^{117m}\mathrm{Sn}, and 123mSn{}^{123m}\mathrm{Sn} region exhibits the three adjacent peaks. To de-convolve these, we used a triple-Gaussian with a piecewise linear background that changes slope at the main centroid μ2\mu_2, corresponding to the middle peak (158.56 keV):

f117m(E)={C2σ22πe−(E−μ2)22σ22+C1σ22πe−(E−μ1)22σ22+b1E+m1,E<μ2,C2σ22πe−(E−μ2)22σ22+C3σ22πe−(E−μ3)22σ22+b2E+m2,E≥μ2.(7)f_{117m}(E)= \begin{cases} \frac{C_2}{\sigma_2\sqrt{2\pi}}e^{-\frac{(E-\mu_2)^2}{2\sigma_2^2}}+\frac{C_1}{\sigma_2\sqrt{2\pi}}e^{-\frac{(E-\mu_1)^2}{2\sigma_2^2}}+b_1E+m_1, & E<\mu_2,\\ \frac{C_2}{\sigma_2\sqrt{2\pi}}e^{-\frac{(E-\mu_2)^2}{2\sigma_2^2}}+\frac{C_3}{\sigma_2\sqrt{2\pi}}e^{-\frac{(E-\mu_3)^2}{2\sigma_2^2}}+b_2E+m_2, & E\ge\mu_2. \end{cases} \tag*{(7)}

where C1,2,3C_{1,2,3} are the net areas of the lower-adjacent, middle, and upper-adjacent peaks, respectively; μ1,2,3\mu_{1,2,3} their centroids; and σ2\sigma_2 the common width. Centroids and width were fixed to calibration values; areas and background terms were floated.

Because C3C_3 represents the net area under the 123mSn{}^{123m}\mathrm{Sn}’s 160.34 keV peak, the 123mSn{}^{123m}\mathrm{Sn} half-life analysis is performed us-

ing the same function in equation (7).

Iterative Decay Correction and Half-Life Refinement

For each spectrum, the activity at the reference time was computed from the fitted peak net area using:

A(t)=CiλΔtrealΔtliveϵiIγ(1−e−λΔtreal)(8)A(t) = \frac{C_i \lambda\dfrac{\Delta t_{real}}{\Delta t_{live}}}{\epsilon_i I_\gamma\left(1-e^{-\lambda\Delta t_{real}}\right)} \tag*{(8)}

where ϵi\epsilon_i is the efficiency (applied though not required for half-life determination), IγI_\gamma the emission probability, Δtreal\Delta t_{real} the real counting time, Δtlive\Delta t_{live} the live counting time, and λ=ln⁡2/T1/2\lambda= \ln2/T_{1/2} the decay constant.

We note that the formulation used in Eq. (8) is fully consistent with established practice in activation-based γ\gamma-spectrometry measurements, as demonstrated in peer-reviewed studies in closely related experimental contexts Zaman et al. [25]; Naik et al. [17]. The factor Δtreal/Δtlive\Delta t_{real}/\Delta t_{live} corrects for fractional counting losses within the acquisition window, while the bracketed term (1−e−λΔtreal)(1-e^{-\lambda\Delta t_{real}}) accounts for true physical decay during the finite real elapsed interval. For our multichannel analyzer (MCA) acquisition system operating under low dead-time conditions (<0.2%< 0.2\% for 117mSn^{117m}\mathrm{Sn} and <0.8%< 0.8\% for 110Sn^{110}\mathrm{Sn} during fitted intervals), dead time is non-extending and stable throughout each counting interval (Δt≪T1/2\Delta t \ll T_{1/2}). We evaluated alternative formulations (such as replacing Δtreal\Delta t_{real} in the decay correction factor with Δtlive\Delta t_{live}, or implementing a generalized dead-time algorithm); the resulting differences in the extracted half-lives were strictly below 0.01%0.01\%, demonstrating that the choice of correction formulation has a negligible effect on our results.

Half-life determination followed an iterative procedure:

  1. Initialize T1/2T_{1/2} with the NDS recommended value, T1/2(0)T_{1/2}^{(0)}.

  2. Correct activities using Eq. (8).

  3. Fit activity vs. time to:

A(t)=A0e−λ(n)t.(9)A(t) = A_0 e^{-\lambda^{(n)}t}. \tag*{(9)}
  1. Update T1/2(n)T_{1/2}^{(n)}, the nthn^{\mathrm{th}} iteration value of the half-life, and repeat until:

∣T1/2(n)−T1/2(n−1)T1/2(n−1)∣<1%.\left|\frac{T_{1/2}^{(n)}-T_{1/2}^{(n-1)}}{T_{1/2}^{(n-1)}}\right| < 1\%.

Results

110Sn Decay Analysis

Figure 9 illustrates the decay behavior of 110Sn^{110}\mathrm{Sn} derived from the 280.49 keV γ\gamma line. The fit quality is characterized by χ2/ndf=388.4/325\chi^2/\mathrm{ndf} = 388.4/325 and p=8.96×10−3p = 8.96 \times10^{-3}, indicating a statistically acceptable model. The extracted half-life is:

Image not extracted

Figure 9. Decay curve for 110Sn^{110}\mathrm{Sn} derived from the 280.49 keV γ\gamma line. The data were fitted with a single-exponential decay model (red line) to extract the half-life. Early measurements (0–6 h post-irradiation) were excluded due to high dead-time (higher than 10%), while all fitted points have dead-time between 0.30% and 0.77%. Live counting time was set to 180 s.

T1/2(110Sn g.s.)=(4.165±0.025) h,T_{1/2}(^{110}\mathrm{Sn\ g.s.}) = (4.165 \pm0.025)\ \mathrm{h},

which is in close agreement with the NDS recommended value of (4.154±0.004) h(4.154 \pm0.004)\ \mathrm{h} Gürdal and Kondev [11].

113Sn Decay Analysis

Figure 10 shows the activity-versus-time dataset and the single-exponential fit for the 391.697 keV line of 113Sn^{113}\mathrm{Sn}. The fit quality is evident (χ2/ndf=471.9/457\chi^2/\mathrm{ndf} = 471.9/457, p=0.305p = 0.305), indicating that a single-component exponential decay adequately describes the data over the acquisition period.

Image not extracted

Figure 10. Decay curve for 113Sn^{113}\mathrm{Sn} based on the 391.697 keV γ\gamma line. Data points represent measured activity over time; the solid line shows the best-fit single-exponential decay. The fit includes data starting at 15 h (900 min) after the end of irradiation to avoid contamination from the 391.698 keV line of 113In^{113}\mathrm{In} (T1/2T_{1/2} = 99.476 min) and extends to slightly beyond 6000 h post-irradiation. The counting live time was adjusted throughout the measurements to appropriately allow for other isotopic half-life determinations.

From the fit to Eq. (9), we obtain:

T1/2(113Sn g.s.)=(116.08±0.94) d.(10)T_{1/2}(^{113}\mathrm{Sn\ g.s.}) = (116.08 \pm0.94)\ \mathrm{d}. \tag*{(10)}

The relative deviation is:

116.08−115.09115.09×100%≈0.86%.\frac{116.08-115.09}{115.09} \times100\% \approx0.86\%.

To verify that the 391.698 keV emission from isomeric 113mIn^{113m}\mathrm{In} (T1/2=99.476 minT_{1/2} = 99.476\ \mathrm{min}), produced directly during photon activation, does not distort the fitted 113Sn^{113}\mathrm{Sn} decay slope, a sensitivity test was conducted by systematically varying the fitting start time between 5 h and 30 h post-irradiation. While fitting initialized before 10 h exhibited a slight deviation due to transient non-equilibrium of 113mIn^{113m}\mathrm{In}, the extracted half-life remained stable to within 0.05% for all start times ≥15\geq15 h. Restricting the fit to t≥15t \geq15 h (corresponding to >9> 9 half-lives of 113mIn^{113m}\mathrm{In}) ensures full secular equilibrium and confirms that direct precursor contributions do not bias the reported 113Sn^{113}\mathrm{Sn} half-life.

117mSn Decay Analysis

Figure 11 presents the decay analysis for 117mSn^{117m}\mathrm{Sn} using the 158.56 keV line. The fit quality is evident (χ2/ndf=312.4/305\chi^2/\mathrm{ndf} = 312.4/305, p=0.389p = 0.389), and the extracted half-life is:

Image not extracted

Figure 11. Decay curve for 117mSn^{117\mathrm{m}}\mathrm{Sn} based on the 158.56 keV γ\gamma line. Measured activity points are fitted with a single-exponential decay model. To eliminate early feeding from the decay of 117In^{117}\mathrm{In} (both ground state, T1/2T_{1/2} = 43.2 min, and isomeric state, T1/2T_{1/2} = 116.1 min), the fit was restricted to data collected starting 50 h after the end of irradiation. Additionally, the dead-time of the counting spectra that are used in this fit was always less than 0.2%.

T1/2(117mSn)=(13.95±0.01) d.T_{1/2}(^{117m}\mathrm{Sn}) = (13.95 \pm0.01)\ \mathrm{d}.

Compared to the NDS recommended value of (13.76±0.04)(13.76 \pm0.04) d Blachot [2], the deviation is small but statistically significant. Such differences can propagate into decay-correction protocols and dosimetric calculations in nuclear medicine, directly impacting absorbed dose estimates and therapeutic efficacy.

123mSn^{123\mathrm{m}}\mathrm{Sn} Decay Analysis

Figure 12 shows the decay analysis for 123mSn^{123\mathrm{m}}\mathrm{Sn} based on its characteristic 160.34 keV γ\gamma emission. The fit was performed following the same iterative correction approach, yielding χ2/ndf=15.73/17\chi^2/\mathrm{ndf} = 15.73/17 and p=0.543p = 0.543. The extracted half-life is:

Image not extracted

Figure 12. Decay curve for 123mSn^{123\mathrm{m}}\mathrm{Sn}. Activity data points were fitted with a single-exponential decay model (red line) using an iterative correction approach. Only measurements with dead-time below 10% were included in the fit after applying the dead-time correction, see equation (8). Each point represents 180 s of live counting time.

T1/2(123mSn)=(39.95±0.12) min.T_{1/2}(^{123\mathrm{m}}\mathrm{Sn}) = (39.95 \pm0.12)\ \mathrm{min}.

Compared to the NDS recommended value of (40.06 ±\pm 0.02) min Chen [6], the difference is small.

Summary of Results

Table 1 summarizes the measured half-lives for 110Sn^{110}\mathrm{Sn}, 113Sn^{113}\mathrm{Sn}, 117mSn^{117\mathrm{m}}\mathrm{Sn} and 123mSn^{123\mathrm{m}}\mathrm{Sn}, obtained using isotope-specific peak models and iterative decay correction, and compares them to the NDS recommended values. Deviations between the measured and evaluated half-lives were quantified using a z-score (standardized difference), defined as

IsotopeEnergy (keV)Fit ModelThis Work T1/2T_{1/2}NDS T1/2T_{1/2}z-score
110Sn^{110}\mathrm{Sn}280.49Gaussian + tail(4.165 ± 0.025) h(4.154 ± 0.004) h Gürdal and Kondev [11]0.435
113Sn^{113}\mathrm{Sn}391.697Single Gaussian(116.08 ± 0.94) d(115.09 ± 0.03) d Blachot [3]1.053
117mSn^{117\mathrm{m}}\mathrm{Sn}158.56Triple Gaussian(13.95 ± 0.01) d(13.76 ± 0.04) d Blachot [2]4.608
123mSn^{123\mathrm{m}}\mathrm{Sn}160.34Triple Gaussian(39.95 ± 0.12) min(40.06 ± 0.02) min Chen [6]-0.904

Table 1. Measured half-lives compared to NDS recommended values. Uncertainties are 1σ1\sigma statistical from the exponential fit. The last column shows the z-score value.

z=xmeas−xevalσmeas2+σeval2.z = \frac{x_{\mathrm{meas}} - x_{\mathrm{eval}}}{\sqrt{\sigma_{\mathrm{meas}}^2 + \sigma_{\mathrm{eval}}^2}}.

where σmeas\sigma_{\mathrm{meas}} and σeval\sigma_{\mathrm{eval}} represent the associated uncertainties. While most isotopes exhibit good agreement within uncertainties (∣z∣≲1|z| \lesssim1), the case of 117mSn^{117\mathrm{m}}\mathrm{Sn} shows a significantly larger deviation, with z=4.608z = 4.608. This elevated z-score clearly underscores the statistical significance of the discrepancy, indicating that the deviation is unlikely to arise from random uncertainty alone. Such a result highlights the need for closer examination, particularly given its potential implications for calibration, dosimetry, and astrophysical modeling.

Uncertainty Considerations

The uncertainties reported in Table 1 represent 1σ1\sigma statistical uncertainties obtained from the weighted exponential fits. Systematic uncertainties were quantitatively evaluated across several categories:

  • Dead-time and pulse pile-up: Spectra utilized for half-life determinations were restricted to low dead-time domains (< 0.8% for 110Sn^{110}\mathrm{Sn} and < 0.2% for 117mSn^{117\mathrm{m}}\mathrm{Sn}). Uncertainty in the live-time clock correction was assessed by comparing alternative correction algorithms and was found to contribute < 0.03% systematic uncertainty to the decay constant.

  • Peak integration and background model: Systematic effects from region-of-interest boundary selection, tailing parameters, and piecewise background slopes were evaluated by varying fitting intervals and background formulations across the decay sequence. The resulting area variation contributed < 0.05% uncertainty to the extracted half-lives.

  • Geometry and detector stability: Samples were mounted in rigid reproducibility holders ensuring position reproducibility within Δx<0.1\Delta x < 0.1 mm. Detector gain and resolution stability were monitored across runs using calibration lines; centroid drift remained within < 0.1 channel, contributing < 0.02% to the decay slope uncertainty.

  • Timing accuracy: System acquisition start/stop times and hardware timestamps were verified against synchronized network time servers, yielding negligible systematic error (< 10−410^{-4}%).

For 117mSn^{117\mathrm{m}}\mathrm{Sn}, where the statistical uncertainty is exceptionally small (±0.01 d, or 0.072%), the combined systematic uncertainty in quadrature is estimated to be ±0.008 d (0.057%). Because this systematic bound is smaller than the quoted statistical uncertainty, the reported precision is realistic and robust.

Discussion

This work provides independent verification of evaluated half-lives through photon activation of natural tin and long-term HPGe monitoring. In several cases, these measurements represent the only determinations obtained via a photo-nuclear production route for the isotope or its isomeric state, offering a unique complement to the established dataset.

Generally speaking, the NDS methodology consolidates results from a wide range of experimental techniques, including charged-particle reactions such as (α,2n)(\alpha, 2n), (p,t)(p, t), and (d,p)(d, p), Coulomb excitation, photo-nuclear processes, and neutron-capture routes. For example, the adopted half-life of 110Sn^{110}\mathrm{Sn} (4.154 h) reflects a weighted average of measurements from (α,2nγ)(\alpha, 2n\gamma) reaction on 108Cd^{108}\mathrm{Cd}, (p,t)(p, t) reaction on 112Sn^{112}\mathrm{Sn}, Coulomb excitation studies, and other routes, with uncertainties primarily statistical. Similarly, 113Sn^{113}\mathrm{Sn} values originate from activation via (α,nγ)(\alpha, n\gamma) reaction on 110Cd^{110}\mathrm{Cd}, (p,nγ)(p, n\gamma) reaction on 113In^{113}\mathrm{In}, (p,t)(p, t) reaction on 115Sn^{115}\mathrm{Sn}, and (n,γ)(n, \gamma) reaction on 112Cd^{112}\mathrm{Cd}, complemented by decay studies following ε\varepsilon capture. For 117mSn^{117\mathrm{m}}\mathrm{Sn}, the NDS recommendation (13.76 d) aggregates results from β−\beta^- decay chains of 117In^{117}\mathrm{In}, internal transition studies, and multiple charged-particle reactions, such as (α,γ)(\alpha, \gamma) reaction on 114Cd^{114}\mathrm{Cd}, and (d,p)(d, p) reaction on 116Sn^{116}\mathrm{Sn}, and neutron radiative capture on 116Sn^{116}\mathrm{Sn}, while 123mSn^{123\mathrm{m}}\mathrm{Sn} values are based on decay monitoring after (d,p)(d, p) and (n,γ)(n, \gamma) reactions on 122Sn^{122}\mathrm{Sn}.

Our approach differs in two key aspects: (i) the use of photon activation, which enables simultaneous production of multiple isotopes under identical conditions and minimizes contamination from competing reaction channels, and (ii) strict control of systematic effects, including dead-time correction and exclusion of early-time spectra to mitigate feeding from short-lived precursors (e.g., 117In^{117}\mathrm{In}). These measures allow high-precision determinations, defined here as results with relative uncertainties below 1%, ensuring reliability for applications in nuclear medicine and astrophysical modeling.

Key findings for individual isotopes are summarized below:

110Sn^{110}\mathrm{Sn}: Our result agrees within uncertainties with the NDS value, supporting its reliability for astrophysical pp-process modeling, where accurate half-lives constrain reaction rates near the Z=50Z = 50, N=50N = 50 shell closures.

113Sn^{113}\mathrm{Sn}: Although the measured half-life differs by 0.86% from the NDS recommendation (with z-score = 1.053), this discrepancy—though small, highlights the importance of reexamining reference values used in HPGe efficiency calibrations. Even sub-percent deviations can propagate into systematic errors in detector standards.

117mSn^{117\mathrm{m}}\mathrm{Sn}: The measured value of (13.95 ± 0.01) d exceeds the older NDS recommendation of (13.76 ± 0.04) d by 1.38% (z=4.608z = 4.608), representing a statistically significant deviation. However, our result does not stand isolated from previous experimental work; it is in close agreement with the precision experimental measurement of (13.91 ± 0.03) d reported by Domingo et al. Domingo et al. [8] using HPGe spectroscopy. The current NDS evaluation reflects a weighted average that incorporates historical measurements favoring shorter half-lives (13.60–13.76 d). By utilizing high-resolution HPGe spectroscopy on photon-activated tin and initiating fits after 50 h to eliminate 117In^{117}\mathrm{In} feeding, our measurement provides an independent, low-background verification that corroborates the recent determination by Domingo et al. Domingo et al. [8]. Because 117mSn^{117m}\mathrm{Sn} is an important therapeutic radionuclide, adopting an accurate half-life is critical for absorbed dose calculations and clinical radiopharmaceutical release criteria.

123mSn^{123m}\mathrm{Sn}: The measured half-life is about 0.28% lower than the NDS recommendation (z-score = -0.904), within one standard deviation.

Overall, these results underscore the importance of independent verification using alternative production mechanisms and stringent uncertainty criteria. Periodic reevaluation of medically relevant isotopes remains essential to maintain confidence in nuclear data libraries and their downstream applications.

Conclusions

Two short photon activations of natural tin were performed to produce measurable activities of 110Sn^{110}\mathrm{Sn}, 113Sn^{113}\mathrm{Sn}, 117mSn^{117m}\mathrm{Sn}, and 123mSn^{123m}\mathrm{Sn} suitable for short- and long-term HPGe monitoring. The primary irradiation used a 6 mm Ta converter and a 40 MeV electron beam, while a secondary irradiation at 36 MeV with a single 3 mm W plate was carried out as part of a broader photonuclear reaction cross-section test. Extended counting intervals (180 s) were applied only to the second irradiation to enable a precise determination of the 110Sn^{110}\mathrm{Sn} half-life; all other isotopes were analyzed from the first irradiation.

Based on isotope-specific peak models (single Gaussian, triple Gaussian, and Gaussian with tail) and iterative decay correction, the following half-lives were determined:

  • 110Sn^{110}\mathrm{Sn}: T1/2=(4.165±0.025)T_{1/2} = (4.165 \pm0.025) h,

  • 113Sn^{113}\mathrm{Sn}: T1/2=(116.08±0.94)T_{1/2} = (116.08 \pm0.94) d,

  • 117mSn^{117m}\mathrm{Sn}: T1/2=(13.95±0.01)T_{1/2} = (13.95 \pm0.01) d,

  • 123mSn^{123m}\mathrm{Sn}: T1/2=(39.95±0.12)T_{1/2} = (39.95 \pm0.12) min.

The measured half-lives of 110Sn^{110}\mathrm{Sn}, 113Sn^{113}\mathrm{Sn}, and 123mSn^{123m}\mathrm{Sn} agree with NDS recommendations within experimental uncertainties (∣z∣≤1.05|z| \le1.05). For 117mSn^{117m}\mathrm{Sn}, our measured value of (13.95±0.01)(13.95 \pm0.01) d deviates significantly from the older NDS recommendation ((13.76±0.04)(13.76 \pm0.04) d, z=4.608z = 4.608), but closely aligns with the experimental measurement of Domingo et al. Domingo et al. [8] ((13.91±0.03)(13.91 \pm0.03) d). These results provide valuable independent experimental input for nuclear data libraries, demonstrating the capability of photon activation to produce clean decay benchmarks for astrophysics, detector calibration, and medical dosimetry.

Acknowledgments

The authors would like to thank the accelerator operators and the health physics team at NorthStar Medical Radioisotopes (NMR) for the stable and safe operation of the machine and safety and logistical support.

References

  1. [1]Arnould, M., Goriely, S., 2003. The p-process of stellar nucleosynthesis: Astrophysics and nuclear physics status. Physics Reports 384, 1–84. URL: https://doi.org/10.1016/S0370-1573(03)00242-4, doi:10.1016/S0370-1573(03)00242-4.
  2. [2]Blachot, J., 2002. Nuclear data sheets for a = 117. Nuclear Data Sheets 95, 679–836. URL: https://doi.org/10.1006/ndsh.2002.0007, doi:10.1006/ndsh.2002.0007.
  3. [3]Blachot, J., 2005. Nuclear data sheets for a = 113. Nuclear Data Sheets 104, 791–966. URL: https://doi.org/10.1016/j.nds.2005.03.002, doi:10.1016/j.nds.2005.03.002.
  4. [4]Bork, J., Schatz, H., Käppeler, F., Rauscher, T., 1998. Proton capture cross sections of the ruthenium isotopes. Physical Review C 58, 524–535. URL: https://doi.org/10.1103/PhysRevC.58.524, doi:10.1103/PhysRevC.58.524.
  5. [5]Boschi, A., Uccelli, L., Martini, P., 2019. A picture of modern tc-99m radiopharmaceuticals: Production, chemistry, and applications in molecular imaging. Applied Sciences 9, 2526. URL: https://doi.org/10.3390/app9122526, doi:10.3390/app9122526.
  6. [6]Chen, J., 2021. Nuclear data sheets for a=123. Nuclear Data Sheets 174, 1–463. URL: https://doi.org/10.1016/j.nds.2021.05.001, doi:10.1016/j.nds.2021.05.001.
  7. [7]Chloupek, F.R., Murphy, A.S.J., Boyd, R.N., Cole, A.L., Görres, J., Güray, R.T., Raimann, G., Zach, J.J., Rauscher, T., Schwarzenberg, J.V., Tischhauser, P., Wiescher, M.C., 1999. Measurements of proton radiative capture cross sections relevant to the astrophysical rp- and γ-processes. Nuclear Physics A 652, 391–405. URL: https://doi.org/10.1016/S0375-9474(99)00167-0, doi:10.1016/S0375-9474(99)00167-0.
  8. [8]Domingo, T., Starosta, K., Chester, A., Williams, J., 2017. A precise measurement of the 117mSn half-life. Applied Radiation and Isotopes 119, 101–104. URL: https://doi.org/10.1016/j.apradiso.2016.11.010, doi:10.1016/j.apradiso.2016.11.010.
  9. [9]Emery, G.T., 1972. Perturbation of nuclear decay rates. Annual Review of Nuclear and Particle Science 22, 165–202. URL: https://doi.org/10.1146/annurev.ns.22.120172.001121, doi:10.1146/annurev.ns.22.120172.001121.
  10. [10]Goriely, S., 1998. Radiative neutron captures by neutron-rich nuclei and the r-process nucleosynthesis. Physics Letters B 436, 10–18. URL: https://doi.org/10.1016/S0370-2693(98)00907-1, doi:10.1016/S0370-2693(98)00907-1.
  11. [11]Gürdal, G., Kondev, F.G., 2012. Nuclear data sheets for a=110. Nuclear Data Sheets 113, 1315–1561. URL: https://doi.org/10.1016/j.nds.2012.05.002, doi:10.1016/j.nds.2012.05.002.
  12. [12]Gyürky, G., Kiss, G.G., Elekes, Z., Fülöp, Z., Somorjai, E., Palumbo, A., Görres, J., Lee, H.Y., Rapp, W., Wiescher, M., Özkan, N., Güray, R.T., Efe, G., Rauscher, T., 2006. α-induced cross sections of 106Cd for the astrophysical p process. Physical Review C 74, 025805. URL: https://doi.org/10.1103/PhysRevC.74.025805, doi:10.1103/PhysRevC.74.025805.
  13. [13]Hoppes, D.D., Schima, F.J., 1982. Nuclear Data for the Efficiency Calibration of Germanium Spectrometer Systems: Measurements from the Laboratories of the ICRM α-, β-, and γ-Ray Spectrometry Group. Technical Report 626. National Bureau of Standards. Washington, DC. URL: https://doi.org/10.6028/NBS.SP.626, doi:10.6028/NBS.SP.626.
  14. [14]Houtermans, H., Milosevic, O., Reichel, F., 1980. Half-lives of 35 radionuclides. The International Journal of Applied Radiation and Isotopes 31, 153–154. URL: https://doi.org/10.1016/0020-708X(80)90139–8, doi:10.1016/0020-708X(80)90139–8.
  15. [15]Lagoutine, F., Legrand, J., Perrot, C., Brethon, J.P., Morel, J., 1972. Half-lives of a few radionuclides. The International Journal of Applied Radiation and Isotopes 23, 219–224. URL: https://doi.org/10.1016/0020-708X(72)90058–0, doi:10.1016/0020-708X(72)90058–0.
  16. [16]Maslov, O.D., Starodub, G.Y., Vostokin, G.K., Gustova, M.V., Dmitriev, S.N., Shvetsov, V.N., Szücs, Z., Jansen, D., Zeevaart, J.R., 2011. Production of 117mSn with high specific activity by cyclotron. Applied Radiation and Isotopes 69, 965–968. URL: https://doi.org/10.1016/j.apradiso.2011.02.031, doi:10.1016/j.apradiso.2011.02.031.
  17. [17]Naik, H., Kim, G., Nguyen, T.H., Kim, K., Shin, S.G., Kye, Y.U., Cho, M.H., 2020. Measurement of natNi(γ, xn)57,56,55ni and natNi(γ, pxn)58–55Co reaction cross sections in bremsstrahlung with end-point energies of 65 and 75 mev. Journal of Radioanalytical and Nuclear Chemistry 324, 837–846. URL: https://doi.org/10.1007/s10967-020-07105-9, doi:10.1007/s10967-020-07105-9.
  18. [18]Rauscher, T., Thielemann, F.K., 2001. Tables of nuclear cross sections and reaction rates: An addendum to the paper “astrophysical reaction rates from statistical model calculations”. Atomic Data and Nuclear Data Tables 79, 47–64. URL: https://doi.org/10.1006/adnd.2001.0863, doi:10.1006/adnd.2001.0863.
  19. [21]Sauter, T., Käppeler, F., 1997. (γ,γ) rates of 92,94,95,98Mo: Towards an experimentally founded database for p-process studies. Physical Review C 55, 3127–3138. URL: https://doi.org/10.1103/PhysRevC.55.3127, doi:10.1103/PhysRevC.55.3127.
  20. [22]Stevenson, N.R., St. George, G., Simón, J., Srivastava, S.C., Mueller, D.W., Gonzales, G.R., Rogers, J.A., Frank, R.K., Horn, I.M., 2015. Methods of producing high specific activity sn-117m with commercial cyclotrons. Journal of Radioanalytical and Nuclear Chemistry 305, 99–108. URL: https://doi.org/10.1007/s10967-015-4031-7, doi:10.1007/s10967-015-4031-7.
  21. [23]Unterweger, M.P., Hoppes, D.D., Schima, F.J., 1992. New and revised half-life measurements results. Nuclear Instruments and Methods in Physics Research Section A 312, 349–352. URL: https://doi.org/10.1016/0168-9002(92)90180–C, doi:10.1016/0168-9002(92)90180–C.
  22. [24]Utsunomiya, H., Goriely, S., Kamata, M., Akimune, H., Kondo, T., Itoh, O., Iwamoto, C., Yamagata, T., Toyokawa, H., Lui, Y.W., Harada, H., Kitatani, F., Goko, S., Hilaire, S., Koning, A.J., 2011. Photoneutron cross sections for 118,124Sn and the γ-ray strength function method. Physical Review C 84, 055805. URL: https://doi.org/10.1103/PhysRevC.84.055805, doi:10.1103/PhysRevC.84.055805.
  23. [25]Zaman, M., Kim, G., Naik, H., Kim, K., Shahid, M., Nadeem, M., Shin, S.G., Cho, M.H., 2018. Flux weighted average cross-sections of natNi(γ, x) reactions with the bremsstrahlung end-point energies of 55, 59, 61 and 65 mev. Nuclear Physics A 978, 173–186. URL: https://doi.org/10.1016/j.nuclphysa.2018.07.017, doi:10.1016/j.nuclphysa.2018.07.017.

Paper details

vlnc:W_27q3xs9b
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 7

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents