WorksPhysics and Astronomy
Angular displacement readout of a mechanical oscillator with a guided mode resonance
Abstract
Measuring the angular displacement of a mechanical oscillator is a ubiquitous task; however, the multimode nature of angular optomechanical coupling makes coherent signal enhancement challenging. Here we demonstrate coherently enhanced angular displacement readout with an integrated guided mode resonance (GMR) structure, applying it to precision readout of a nanomechanical oscillator. Specifically, we fabricate subwavelength gratings into 100-nm-thick SiN membranes and record their vibration by direct transmission measurements. The narrow linewidth of the GMR enables a shot-noise-limited displacement imprecision of with nanowatts of optical power, sufficient to resolve the thermal motion of a torsion mode with a signal-to-noise ratio of 47 dB. Control experiments based on polarization and wavelength detuning confirm that the measured signal arises from GMR-mediated transduction. These results establish guided-mode resonance as an on-chip approach to angular displacement readout in quantum optomechanical sensors.
main.pdf
Angular displacement readout of a mechanical oscillator with a guided mode resonance
Abstract
Precise angular displacement readout of a mechanical oscillator is a common task in science and engineering, from atomic force microscopy [1] to equivalence principle tests [2]. The traditional optical lever method [1–3] offers high sensitivity and quantum efficiency [4], but relies on free-space beam propagation over extended path lengths. Next-generation optomechanical sensors demand both sensitivity and compactness, motivating investigation of photonic structures sensitive to angular displacement. Guided mode resonance (GMR) structures [5–8] present a solution that combines sharp angular response and compatibility with nanofabrication methods used in quantum optomechanics [9–11]; however, to date GMR-based angle sensing has been limited to static [12] and low frequency [13] applications limited by classical noise.
Here we demonstrate use of GMR for shot-noise-limited angular displacement readout of a nanomechanical oscillator. We highlight the coherently-enhanced nature of the readout—a challenge for free-space approaches due the multimode nature of the optomechanical coupling [14]—which manifests in a conventional cavity optomechanical framework [15] as a shot-noise-limited angular displacement imprecision of
where and are the linewidth and optomechanical coupling to the resonance frequency , respectively, is the angular resonance linewidth, and () is the detected optical power (photon flux). By patterning a 25-nm-thick grating into a 100-nm-thick SiN membrane, we realize a μm GMR with THz, GHz/mrad, and mrad, enabling readout of a higher-order membrane mode with an imprecision of using nW (). We conclude by comparing the quantum limits of optical lever and GMR approaches and demonstrating thermal-noise-limited readout of a high- torsion oscillator.
Guided-mode resonance - A brief overview of guided mode resonance (GMR) is germane to understanding our approach. GMRs arise in subwavelength grating slabs that support leaky waveguide modes [5–7]. When incident light is near the
resonance condition , it couples into the mode and interferes with the directly transmitted (or reflected) wave, resulting in a Fano-shaped transmission spectrum (Figure 1a inset)
Figure 1. Optomechanical coupling of a SiN membrane to a guided mode resonance (GMR). (a) Membrane displacement modifies the local angle of incidence of a laser beam incident on an embedded grating slab structure, altering the transmittivity of a GMR. Inset: Orientation of the grating relative to the mechanical mode. (b) Grating geometry: period , duty cycle , grating thickness , waveguide thickness . (c) Photo of 2.5 mm SiN membrane with embedded grating. Inset: scanning electron micrograph of the grating.
where is the background transmittivity of the grating and is a (generally complex) Fano parameter. The GMR linewidth is governed by structural parameters such as the grating period, waveguide and grating thickness, and refractive index contrast, all of which can be finely tuned through simulation [16] and nanofabrication. These features have made GMRs attractive for a diversity of photonic-integrated sensing applications [5] from biology [16–18] to structural engineering [13].
Displacement readout of a mechanical oscillator is enabled by patterning a grating structure onto its surface and monitoring the transmitted (or reflected) field near a GMR resonance. In the limit of small displacement, the GMR can be modeled as sensitive to the local angular displacement
where is the transverse displacement profile of the oscillator and is a unit vector normal to the grating. Monitoring a fraction of the transmitted power then yields a shot-noise-limited angular displacement sensitivity
where expresses the measurement efficiency per incident photon , which depends on the Fano lineshape and detuning (e.g., and for a Lorentzian detuned to maximize ).
To explore these concepts, we fabricated a grating onto a 100-nm-thick, mm wide square membrane, following a standard e-beam lithography and wet-release method [19, 20]. Grating period nm, duty cycle , and thickness nm were chosen according to Rigorous Coupled-Wave Analysis simulations [21] to realize a GMR near normal incidence and nm. The grating was positioned near the membrane center , enabling sensitivity to the antisymmetric second-order flexural mode with local angular displacement .
Optical characterization of the GMR device is shown in Figure 2. We first created a broadband hyperspectral map of the transmittance using a collimated supercontinuum source and spectrometer, yielding qualitative agreement with model over visible wavelengths and incidence angles (Figure 2b,Figure 2c). Higher resolution cross-sections were generated using a wavelength tunable diode laser, revealing a Fano resonance [22] with THz (0.95 nm) and mrad at (Figure 2d,Figure 2e). For these measurements, the laser beam was expanded to a diameter much larger than the grating, and the transmission of a patch of the grating was selected using a CCD camera as shown in the Figure 2e insets.
Figure 2. Optical characterization of guided mode resonance (GMR) device. (a) Experimental setup for measuring wavelength and incidence-angle dependent membrane transmittance using broadband (supercontinuum) and wavelength-tunable narrowband (external cavity diode) laser light. A half-wave plate (HWP) controls the laser polarization. Lens L1 forms a 4f system for spatial filtering with a pinhole. Lenses L2-L4 reimage the laser onto a CCD camera, spectrometer (Spec), or avalanche photodiode (APD). (b) Broadband measurement of using the spectrometer, revealing several GMRs and avoided crossings. (c) Simulated and measured at normal incidence, , for different polarizations. Insets: simulated GMR field profiles. (d) Narrowband measurement of at fixed incidence angle using wavelength-scanned diode laser and CCD for readout. (e) Narrowband measurement of at fixed wavelength using a gimbal mount to tilt the device and CCD for readout. Insets: CCD images at highlighted points. Red boxes indicated pinhole-apertured regions.
Displacement measurements were performed with the sample housed in a high-vacuum chamber ( mbar) and the CCD replaced with a high-speed avalanche photodetector (Thorlabs APD210) and a 100-m-wide pinhole, enabling a local patch of the membrane to be monitored. While silicon nitride membranes with embedded crystal structures have been realized and studied [10, 23, 24], the device for this study exhibited for the targeted antisymmetric mode at kHz (Figure 1a inset), making thermal noise difficult to observe. We therefore performed driven measurements with an external piezo affixed to the vacuum chamber. Driven displacement measurements at frequencies around the near-degenerate and membrane modes are shown in Figure 3a, using a digital lock-in amplifier (Zurich Instruments MFLI) to record the photodetector output . To maximize sensitivity, the chip was tilted to near a resonance at fixed wavelength; the wavelength was then tuned to the corresponding maximum slope on Figure 2d, which is equivalent to the maximum slope in Figure 2e, where nm/mrad [25] is the slope of the resonance contour in Figure 2b. The driven response was converted to PSD units by normalized by lock-in resolution bandwidth, and expressed in displacement units using .
Figure 3. Angular displacement measurements and validation of optomechanical coupling. (a) Driven angular displacement spectra for various detected powers . The two peaks corresponding to degenerate mechanical modes of the square membrane. (b) Noise floor in raw voltage units versus , showing shot-noise scaling for nW. (c) Driven angular displacement spectra for different linear polarizaion orientations of the incident field, varied with a rotatable half waveplate (HWP). (d) RMS displacement versus HWP angle. (e) Detector optical power (black) and RMS displacement versus probe laser wavelength. (f) Spectrograph of displacement spectra (panel a) versus probe laser wavelength.
For detected powers from 9 nW and 380 nW, we infer an angular displacement imprecision from 30 nrad/ to 3 nrad/, respectively. The scaling of the raw noise floor (after subtracting detector noise) is consistent with shot-noise (Figure 3b). Comparing to Eq. (4) with a measured linewidth mrad, we infer a measurement efficiency , times smaller than predicted by the lineshape in Figure 4e.
Figure 4. GMR readout of a nanomechanical torsion oscillator. (a) Microscope image of the device: a 100-nm-thick, 0.4-mm-wide, 7-mm-long SiN nanoribbon [30] with embedded grating similar to that in Figure 1. (b) Thermal-noise-limited readout of the fundamental torsion mode via GMR transmission and optical lever (OL) methods with varying detected power . (c) Detected power and raw signal variance (area under thermal noise peak) versus wavelength, used to optimize the signal-to-noise ratio in (b). (d) Simulated nanoribbon mechanical modeshapes. (e) Broadband measurements for the data in (b). Inset: Ringdown measurement of torsion mode.
As further confirmation of GMR optomechanical coupling, we repeated displacement measurements as a function of polarization (Figure 3c,Figure 3d) and wavelength (Figure 3e,Figure 3f) for the nominal operating point in Figure 3a. As anticipated, sensitivity was found to depend sinusoidally on input linear polarization angle, vanishing at an angle normal to the grating, where the GMR contrast is minimal. Tuning the laser wavelength likewise samples different local gradients of the 2D GMR resonance, . For a fixed , the sensitivity is expected to vanish near maxima of the wavelength gradient . This
is corroborated by cross-sections of the driven displacement spectrograph shown in Figure 3e,Figure 3f.
Comparison to an optical lever- Our results show that a GMR structure can serve as an integrated cavity-enhanced angular displacement sensor. It is interesting to compare its performance to that of an optical lever (OL), whose shot-noise-limited displacement sensitivity can be expressed as [4]
where is the diffraction angle of the reflected laser and is the measurement efficiency (for a split photodiode, [4]). Comparing to Eq. (4) at equal incident power and background reflectivity , the GMR sensitivity can be recast as an effective OL spot size
which for mrad corresponds to μm. Recent studies of quantum-limited OL measurements on nanomechanical oscillators [4, 26, 27] have employed similar spot sizes and realized similar measurement efficiencies . A distinction of the GMR is that it is a local displacement probe. This may have significant advantages at low frequencies where apparatus and beam pointing noise are known to limit the sensitivity of OL measurements [27]. It can also enable robust free-space readout of chipscale sensors, by replacing sensitive alignment with wavelength tuning.
Displacement sensitivity limits- In our experiment, the achieved displacement imprecision was limited by the throughput of our plane-wave imaging scheme, which allowed only of the optical power incident on the membrane () to reach the photodetector. In principle is achievable with an aperture-filling laser beam [28], implying that is accessible with our current GMR linewidth and probe power. Achieving greater precision requires decreasing GMR linewidth and, or, increasing power. A practical lower bound is given by the diffraction limit [28, 29], implying a grating probed with should enable , on par with the state-of-the-art OL measurements [4, 26, 27].
Nanomechanical torque sensing- A promising application of GMR-based angular displacement sensing is readout of a nanomechanical torsion oscillator for precision torque sensing [31, 32]. Recently, centimeter-scale SiN nanoribbons have been reported with ultrahigh quality factors at acoustic frequencies , yielding thermal torque sensitivities of and resonant thermal displacements of [30, 33]. Embedding a GMR into such a nanoribbon could enable torque sensitivity with picowatts of optical power. We present progress towards this goal in Figure 4, by fabricating a grating similar to that in Figure 1 into a -wide, -thick, 7-mm-long SiN nanoribbon [30]. Broadband displacement measurements shown in Figure 4b were made by probing the side of a GMR with , revealing a series of thermal noise peaks, including a noise peak at , corresponding to the fundamental torsion mode. Bootstrapping a Lorentzian fit to the simulated peak thermal displacement , we infer a readout imprecision of , qualitatively consistent with the direct calibration in Figure 3a. Independent of calibration, the high signal-to-noise ratio corresponds to realizing a thermal torque sensitivity of [30] over a bandwidth of .
Summary & outlook - We have explored optomechanical coupling to a guided mode resonance (GMR) as a method for coherently-enhanced angular displacement readout of a mechanical oscillator [14], comparing its quantum limits to that of the optical lever [4], and conducting proof-of-principle experiments with SiN membranes patterned with subwavelength gratings. Using direct transmission measurements, we realized sensitivity with nanowatts of optical power, limited by a diffraction-limited angular GMR linewidth , and corresponding to a quantum efficiency. We applied this displacement sensitivity to readout of a high- SiN torsion nanoribbon, resolving thermal noise with a 47 dB signal-to-noise ratio, corresponding to a 0.1 aNm/ torque sensitivity over an 8 Hz bandwidth.
Looking forward, combining low loss and lithographic control over the optomechanical properties of suspended GMR structures offers diverse opportunities. Hybrid GMR-Fabry-Perot cavities have been widely explored [34, 35] and offer a route to enhanced optomechanical interactions [36, 37]. Our focus has been on direct GMR optomechanical coupling to angular displacement, reducing engineering complexity and avoiding constraints posed by the nondegeneracy of Fabry–Perot spatial modes [14]. A promising application is optomechanical inertial sensing [38], which requires integrated displacement readout methods that are both sensitive and robust to parasitic vibrations, and for which chip-scale torsion oscillators have emerged as an attractive platform [39]. GMR optomechanical coupling is also not limited to angular displacement [40]. Matching the local grating orientation to the gradient of the mechanical modeshape can enable selective coupling to specific mechanical modes, as well as tailored intra- and intermodal coupling between transverse spatial modes of the optical field [41]. In conjunction with high- nanomechanics [42], this approach could provide a general framework for resonant spatial-mode optomechanics.
Acknowledgements
The authors thank Atkin Hyatt and Justin Murante for helpful discussions and experimental assistance. This work was supported by the National Science Foundation (NSF), award no. 2209473 and by the Office of Naval Research MURI, award no. N000142612102. D.T.B. acknowledges additional support from the Friends of Tucson Optics scholarship. O.E.A. acknowledges support from the Secretaría de Ciencia, Humanidades, Tecnología e Innovación (SECIHTI), Mexico (CVU 2023435). The reactive ion etcher used for this study was funded by an NSF MRI grant, ECCS-1725571.
References
Supplemental Information for “Angular displacement readout of a mechanical oscillator with a guided mode resonance”
D. Torres-Barajas; O. Angulo; A. R. Agrawal; M. ElKabbash; D. J. Wilson
SI.pdf
Here we provide details about the method used to a fabricate nanoribbon with embedded subwavelength grating shown in Figure 4 of the main text.
Fabrication of membranes with embedded gratings
A photograph of the device described in Figure 4 of the main text—a nanoribbon with embedded subwavelength grating—is shown in Figure S1. The process flow for fabrication of this device is shown in Figure S2, and is identical to that used for the patterned membrane described in main text Figure 1–Figure 3. Details are provided below.
Figure S1. Photograph of nanoribbon with embedded subwavelength grating after KOH etching.
Figure S2. Process flow. (a) Starting chip. (b) Spin-coated electron beam resist. (c) Written grating pattern on the resist. (c) Pattern is transferred to the by dry etching. (e) Resist residue is cleaned. (f) Device is released by wet etching.
Patterning of subwavelength grating
The fabrication procedure starts with a 100-nm-thick membrane or nanoribbon prepatterned on a 200--thick Si chip with a backwindow (Figure S2), following the procedure described in [1]. The grating is patterned using electron beam lithography (EBL, Elionix ELS-7000) and exposed using ZEP520A as a resist (Figure S2). For alignment of the grating pattern on the membrane, the stage coordinates of the corners of the chip were used (found using the SEM function of the EBL machine). Exposure parameters are summarized in Table 1.
| Beam current | 300 pA | Dots per field | 240000 |
| Aperture | 60 | Dose | 390 |
| Field size | 600 | Resist thickness | 400 nm |
Table 1. Electron-beam exposure parameters.
Pattern transfer and release
After the exposure, the pattern was developed by immersion in Amyl Acetate for 3 minutes, followed by an IPA rinse (Figure S2). The pattern is transferred to the using RIE with , in this case we etched 20 nm deep into the film (Figure S2). The e-beam resist is then cleaned using 2 consecutive immersions in NMP at 80°C for 5 min each, followed by water and IPA rinses (Figure S2). The release is then performed in a 30% KOH solution at 80°C (Figure S2).
References
- [34]O. Černotík, A. Dantan, and C. Genes, Cavity quantum electrodynamics with frequency-dependent reflectors, Physical Review Letters 122, 243601 (2019).DOI
- [35]J. M. Fitzgerald, S. K. Manjeshwar, W. Wieczorek, and P. Tassin, Cavity optomechanics with photonic bound states in the continuum, Physical Review Research 3, 013131 (2021).DOI
- [36]J. Monsel, A. Ciers, S. K. Manjeshwar, W. Wieczorek, and J. Splendsteasser, Dissipative and dispersive cavity optomechanics with a frequency-dependent mirror, Physical Review A 109, 043532 (2024).DOI
- [37]T. Mitra, G. Singh, S. P. Madsen, and A. Dantan, Cavity optomechanics with a suspended resonant mirror, arXiv preprint arXiv:2608.02488 (2026).arxiv.org/abs/2608.02488
- [38]X. Liu, W. Liu, Z. Ren, Y. Ma, B. Dong, G. Zhou, and C. Lee, Progress of optomechanical micro/nano sensors: a review, International Journal of Optomechatronics 15, 120 (2021).DOI
- [39]C. Condos, J. Pratt, J. Manley, A. Agrawal, S. Schlaminger, C. Pluchar, and D. Wilson, Ultralow loss torsion micropendula for chipscale gravimetry, Phys. Rev. Lett. 134, 253602 (2025).DOI
- [40]S. Zanotto, G. Conte, L. Bellieres, A. Griol, D. Navarro-Urrios, A. Tredicucci, A. Martínez, and A. Pitanti, Optomechanical modulation spectroscopy of bound states in the continuum in a dielectric metasurface, Physical Review Applied 17, 044033 (2022).DOI
- [41]C. M. Pluchar, W. He, J. Manley, N. Deshler, S. Guha, and D. J. Wilson, Imaging-based quantum optomechanics, Physical Review Letters 135, 023601 (2025).DOI
- [42]N. J. Engelsen, A. Beccari, and T. J. Kippenberg, Ultrahigh-quality-factor micro- and nanomechanical resonators using dissipation dilution, Nature Nanotechnology 19, 725 (2024).DOI