WorksEngineering
Continuous Phase-Coherent Readout of a Magneto-Mechanical Resonator Using a Phase-Locked Loop
Abstract
Magneto-mechanical resonators are wireless sensors that encode a measurand in their natural frequency. Existing systems estimate this frequency from repeated cycles of excitation and ring-down, which limits the precision and bandwidth range. Here, we introduce a continuous, phase-coherent readout based on a phase-locked loop. In a benchtop setup, one record stayed within 4 % of the precision-bandwidth limit over more than three decades of bandwidth, while conventional readouts remained about a factor of 4 above it.