betaFeedback

WorksPhysics and Astronomy

Orientation-dependent sensitivity of the all-sky all-frequency gravitational-wave radiometer search to continuous-wave sources

Abstract

The all-sky all-frequency (ASAF) gravitational-wave radiometer search cross-correlates the data of two detectors with equal weight on the ++ and ×\times tensor polarizations. This is optimal for an unpolarized stochastic background, but not for continuous-wave (CW) sources, whose polarization depends on the inclination angle ιι and the polarization angle ψψ. Unless the source is seen face-on, the search measures less power than a face-on source with the same intrinsic amplitude, and underestimates its strength. The ratio of the two powers, the projection factor μ2(ι,ψ)μ^2(ι,ψ), is known from earlier radiometer studies. We show how μ2μ^2 enters the ASAF statistic, derive its exact dependence on ψψ, and prove that its average over orientations is exactly 2/52/5, independent of sky position, baseline geometry, noise weighting, and frequency. We apply the formalism to four simulated pulsar signals at four sky positions, with polarization from circular to nearly linear, injected into the LIGO detectors during the second observing run (O2). A nearly edge-on injection is measured with a signal-to-noise ratio (SNR) of 5.205.20, below the threshold of 6.196.19, while the same signal seen face-on would have an SNR of 31.1±6.031.1 \pm 6.0. Bayesian upper limits on the strain amplitude h0h_0, marginalized over orientation and calibration uncertainty, are 2.72.7 to 2.92.9 times the face-on values. For the 505505 sub-threshold candidates of the first part of the fourth LIGO-Virgo-KAGRA observing run (O4a), the upper limits increase by a factor of 2.52.5 to 2.92.9, and a source of the same strength would reach threshold only when inclined by less than 34.7∘34.7^{\circ} to 50.3∘50.3^{\circ} from face-on. The measured SNR and the significance of every candidate are unchanged.

Introduction

The detection of gravitational waves (GWs) by the LIGO-Virgo-KAGRA (LVK) collaboration [1, 2, 3, 4, 5, 6, 7] has opened new observational windows onto compact astrophysical objects [8, 9, 10]. Across the first three observing runs (O1–O3) and the first part of the fourth (O4a), the network has cataloged over 200 compact binary coalescences [11, 12, 13, 14, 15]. As detector sensitivity continues to improve, additional signal classes are expected to become detectable. These include persistent quasi-monochromatic emission from isolated, deformed neutron stars [16, 17, 18] [19], gravitational-wave bursts from transient sources [20], and stochastic gravitational-wave backgrounds (SGWBs) [21, 22, 23, 24, 25, 26, 27, 28]. An SGWB is produced by the overlap of many weak sources that cannot be resolved individually. The angular distribution of this background carries information about the nature of its sources. A cosmological SGWB, such as one produced by inflation [29, 30], phase transitions [31, 32], or cosmic strings [33, 34, 35, 36], is expected to be nearly isotropic. An astrophysical SGWB, produced by compact objects concentrated along the Galactic plane and in galaxy clusters [37, 38, 39, 40, 41, 42, 43, 44], is expected to be anisotropic.

The standard technique for mapping this angular distribution is gravitational-wave radiometry, which cross-correlates the data of pairs of detectors [21, 45, 46]. Two spatially separated detectors observe the same gravitational-wave signal with a time delay that depends on the source direction. As the Earth rotates, the delay changes, allowing different sky directions to be distinguished during a sidereal day [47, 48, 49]. By accumulating cross-correlated power as a function of both frequency and sky position, one can build a map of the gravitational-wave sky.

Several searches for anisotropic backgrounds have been performed based on this approach [50, 51, 52, 53, 54]. Narrowband radiometer analyses target selected sky positions and frequency intervals [52, 54]. Broadband radiometer analyses map the full sky for a background with an assumed power-law spectrum, combining all frequencies into a single estimate [52, 54]. Spherical harmonic decompositions characterize the angular power spectrum of backgrounds that are extended on the sky, also for an assumed spectral shape [49, 54, 55, 56, 57]. Each method therefore fixes in advance either the sky directions or the spectral shape. None estimates the power independently in every sky direction and at every frequency.

The all-sky all-frequency (ASAF) radiometer search was developed to fill this gap [53]. It computes the cross-correlated power at every frequency bin and every sky pixel, without assuming a source position or spectral shape. It is sensitive to persistent narrowband signals. These include continuous-wave (CW) emission from deformed rotating neutron stars and narrowband stochastic signals from unresolved emitters along a given line of sight [53, 58]. Unlike matched-filter CW searches, ASAF does not search over the parameters of the source. It covers the whole sky and frequency band at a much lower computational cost, at the price of sensitivity, and can therefore serve as a first stage in hierarchical searches [59, 60, 61, 62]. Because it does not model the phase evolution of the signal, it needs no knowledge of the spin-down rate, orbital parameters, or glitch history of the source, as long as the frequency of the signal stays within one frequency bin of the search over the observing run. This makes ASAF well suited to neutron stars with irregular spin evolution [19] and to ultralight-boson condensates around spinning black holes [60, 63, 64].

To date, no radiometer search has yielded a confirmed detection [50, 51, 52, 53, 54]. The ASAF analysis of the O4a data reported a marginal outlier at 92.8125 Hz, where the all-sky map has a minimum signal-to-noise ratio (SNR) of −6.12, just short of the two-sided threshold of −6.18 used in that analysis, and a maximum of 5.2 at a different sky position, which was selected for follow-up. The follow-up checks were inconclusive, and the feature will be monitored in future observing runs [54]. In the absence of a detection, results are reported as upper limits (ULs) on the GW strain amplitude, assuming circular polarization [48, 49, 52, 53, 54, 58]. Since its introduction [53], the ASAF analysis has been studied further. The effect of correlated magnetic noise on its cross-correlation statistic has been quantified [65], a peak-finding algorithm has been proposed to select fewer and less correlated candidates for follow-up [66], and its sub-threshold candidates have been followed up with dedicated CW searches [61, 67]. One issue that has not yet been addressed is how much signal power the search loses when its results are interpreted in terms of CW sources.

The origin of this loss is the equal weight that the cross-correlation statistic gives to the two tensor polarizations, which assumes that they carry equal power [48, 49, 68]. This assumption holds for an unpolarized SGWB. CW sources, however, have emission amplitudes that depend on the inclination angle ι\iota between the neutron star’s spin axis and the line of sight [69, 70]. The two polarization amplitudes are equal only for a face-on source (ι=0\iota= 0). At all other inclinations, the equal-weight statistic measures less power than a face-on source with the same amplitude would produce, and the search underestimates the strength of the source. We call this underestimate the orientation bias. In this work, we quantify it with the projection factor μ2(ι,ψ)\mu^{2}(\iota,\psi), the ratio of the two powers, where ψ\psi is the polarization angle. We apply the formalism to four pulsar hardware injections (PHWIs) [71], simulated pulsar signals physically injected into the LIGO detectors during the second observing run (O2), and to the 505 sub-threshold candidates of the O4a ASAF analysis that were selected for follow-up.

Matched-filter CW pipelines account for inclination dependence by searching over polarization parameters [18, 69, 72], but the current ASAF search does not, since it uses a single template for all orientations. Modeled cross-correlation searches likewise build the (ι,ψ)(\iota,\psi) dependence into their filters [73, 74]. For the SGWB, Boybeyi and Mandic [75] have recently shown that maps that estimate only the total power in each direction are biased when the sky is polarized. The reason is that the detector network does not in general respond to the intensity and to the polarization of a signal in independent ways, so polarized power leaks into the intensity estimate. They remove the bias with a maximum-likelihood analysis of all four Stokes parameters, applied to O3 data. A CW source is a point-like and fully polarized example of the same effect, and the bias studied here is its consequence for the equal-weight ASAF statistic.

The orientation factor that quantifies this bias is not itself new. Averaged over the polarization angle, it falls from unity for a face-on source to one eighth for an edge-on one, with an isotropic average of 2/5 [69] (Sec. III C). Its effect on radiometer searches was derived in Refs. [76, 77], and narrowband radiometer searches have used it to quote ULs marginalized over orientation [54, 78]. What is new here is threefold. First, we prove that the isotropic average of 2/5 holds exactly for the full ASAF statistic at any sky position. Second, we derive the closed form of the residual dependence on the polarization angle. It gives the least favorable orientation and the largest detectable inclination at every sky position, and explains why the marginalized ULs depend only on declination [76]. Third, we propagate the bias through the strain estimate, SNR, detection probability, and ULs of the ASAF search. The ULs still assume circular polarization. With the bias included, each frequency-pixel pair has a range of ULs over orientation instead of a single face-on value.

Section II summarizes the ASAF formalism and analysis settings. Section III derives μ2(ι,ψ)\mu^{2}(\iota,\psi) for CW signals and propagates it through strain, SNR, and detection probability, and Section IV constructs orientation-marginalized ULs. § 2 and VI apply the formalism to the four O2 PHWIs and to the 505 O4a follow-up candidates, and Section VII summarizes the findings.

In this section we summarize the ASAF formalism and analysis settings, following Refs. [22, 48, 49, 52, 53, 54]. As in the O3 and O4a ASAF analyses [53, 54], we analyze frequency bins of width Δf=1/32\Delta f = 1/32 Hz. We divide the sky into Npix=12Nside2N_{\mathrm{pix}} = 12N_{\mathrm{side}}^{2} equal-area HEALPix pixels [79] with Nside=16N_{\mathrm{side}} = 16. This gives 3072 pixels of about 13.4 deg213.4\ \mathrm{deg}^{2} each. The response of a baseline repeats every sidereal day. The data of a full observing run can therefore be folded onto a single sidereal day without loss of directional information. The folded data contain all the data of the run, but cost only as much to analyze and store as a single sidereal day [55, 80, 81]. They are analyzed with PyStoch [55].

Directional strain power

A directional search measures P(f,n^)\mathcal{P}(f,\hat{n}), the one-sided strain power spectral density per unit solid angle at frequency ff in sky direction n^\hat{n}. Its integral over the sky gives the total one-sided strain power spectral density [22]. We expand it on a set of basis functions eμ(n^)e_\mu(\hat{n}),

P(f,n^)=∑μPμ(f)eμ(n^).(1)\mathcal{P}(f,\hat{n}) = \sum_{\mu} \mathcal{P}_{\mu}(f) e_{\mu}(\hat{n}). \tag*{(1)}

The pixel basis, eμ(n^)=δ2(n^−n^μ)e_\mu(\hat{n}) = \delta^2(\hat{n}-\hat{n}_\mu), targets point-like sources, and the spherical harmonic basis, eμ(n^)=Yℓm(n^)e_\mu(\hat{n}) = Y_{\ell m}(\hat{n}), targets spatially extended emission [49, 56]. In this work we look for CW sources, which are point-like on the scale of a pixel. We therefore use the pixel basis.

Cross-spectral density estimator

We measure P(f,n^)\mathcal{P}(f,\hat{n}) by cross-correlating the data of two geographically separated detectors (i=1,2i=1,2), which form a baseline II. Noise that is uncorrelated between the two sites averages out in the cross-correlation, while a GW signal common to both accumulates [21, 22]. For each baseline we construct the complex cross-spectral density (CSD) estimator [21, 52]

CI(t;f)=2Tw1w2‾s~1∗(t;f)s~2(t;f),(2)C^I(t;f)=\frac{2}{T\overline{w_1w_2}}\tilde{s}_1^*(t;f)\tilde{s}_2(t;f), \tag*{(2)}

where s~i(t;f)\tilde{s}_i(t;f) is the short Fourier transform (SFT) of a data segment of duration T=192 sT=192\ \mathrm{s} centered on time tt. The segments are Hann windowed and overlapped by 50%, and the factor w1w2‾\overline{w_1w_2} corrects the estimator for the power removed by the windows [21, 22]. The SFT resolution δf=1/T≃5.2 mHz\delta f=1/T\simeq5.2\ \mathrm{mHz} is coarse-grained to the analysis bin width Δf\Delta f by averaging six adjacent bins.

For Gaussian, stationary noise that is uncorrelated between the sites, the average of the CSD over noise and source realizations is

⟨CI(t;f)⟩=∫d2n^ γI(t;f,n^)P(f,n^).(3)\left\langle C^I(t;f)\right\rangle=\int\mathrm{d}^2\hat{n}\,\gamma^I(t;f,\hat{n})\mathcal{P}(f,\hat{n}). \tag*{(3)}

A single CSD measurement is therefore a weighted integral of the GW power over the whole sky. The weight, the directional response function γI(t;f,n^)\gamma^I(t;f,\hat{n}) defined below, maps the angular distribution of the power onto the measured cross-correlation. It changes as the Earth rotates, and this time dependence is what allows the sky distribution of P\mathcal{P} to be recovered.

Overlap reduction function

The directional response function γI\gamma^I entering Eq. (3) is called the overlap reduction function (ORF) [22, 45, 46, 48, 49, 82]. It quantifies the combined response of the two detectors of a baseline to a GW arriving from a given sky direction, at a given frequency and time. In the pixel basis it reads

γI(t;f,n^)=∑A=+,×F1A(n^,t)F2A(n^,t)e2πifn^⋅Δx⃗I(t)/c,(4)\gamma^I(t;f,\hat{n})=\sum_{A=+,\times}F_1^A(\hat{n},t)F_2^A(\hat{n},t)e^{2\pi if\hat{n}\cdot\Delta\vec{x}^I(t)/c}, \tag*{(4)}

where FiA(n^,t)F_i^A(\hat{n},t) is the antenna pattern function of detector ii for polarization AA, and Δx⃗I(t)\Delta\vec{x}^I(t) is the separation vector between the vertices of the two detectors. The antenna patterns are evaluated in the small-antenna limit, in which the arm length is negligible compared with the GW wavelength [22]. They encode the orientation of the arms of each detector with respect to the incoming wave, and the exponential is the phase delay between the two sites. Both factors depend on time through the rotation of the Earth and return to the same values after one sidereal day, which is what allows the folding described at the beginning of this section.

Pixel-basis estimator

At each frequency bin ff, the goal is to estimate the power Pμ(f)\mathcal{P}_\mu(f) at every pixel μ\mu. Assuming the CSD in each time segment is Gaussian, the maximum-likelihood estimator is [48, 53, 55]

P^μ(f)=∑μ′(Γ−1)μμ′(f)Xμ′(f),(5)\widehat{\mathcal{P}}_\mu(f)=\sum_{\mu'}\left(\Gamma^{-1}\right)_{\mu\mu'}(f)X_{\mu'}(f), \tag*{(5)}

where Xμ(f)X_\mu(f) is the narrowband dirty map and Γμμ′(f)\Gamma_{\mu\mu'}(f) is the narrowband Fisher information matrix [49, 53, 55],

Xμ(f)∝Re⁡∑I,tγμI∗(t;f)CI(t;f)P1(t;f)P2(t;f),(6)X_\mu(f)\propto\operatorname{Re}\sum_{I,t}\frac{\gamma_\mu^{I*}(t;f)C^I(t;f)}{P_1(t;f)P_2(t;f)}, \tag*{(6)}
Γμμ′(f)∝Re⁡∑I,tγμI∗(t;f)γμ′I(t;f)P1(t;f)P2(t;f).(7)\Gamma_{\mu\mu'}(f)\propto\operatorname{Re}\sum_{I,t}\frac{\gamma_\mu^{I*}(t;f)\gamma_{\mu'}^I(t;f)}{P_1(t;f)P_2(t;f)}. \tag*{(7)}

Here γμI(t;f)≡γI(t;f,n^μ)\gamma_\mu^I(t;f)\equiv\gamma^I(t;f,\hat{n}_\mu), and P1,2(t;f)P_{1,2}(t;f) are the one-sided noise power spectral densities of the individual detectors. The sums run over all independent baselines II and time segments tt, and the real part combines the contributions of positive and negative frequencies.

The off-diagonal elements of the Fisher matrix describe the correlations between pixels caused by the finite angular resolution of the baseline. Inverting the full matrix would remove them, but directional blind spots make it highly ill-conditioned [48, 57, 58, 83, 84, 85, 86]. The ASAF search therefore keeps only the diagonal elements [53]. For a point-like source, whose power is contained in a single pixel n^\hat n, the expected dirty map at that pixel is ⟨X^n^⟩=Γn^n^P^n^\langle\hat X_{\hat n}\rangle=\Gamma_{\hat n\hat n}\hat P_{\hat n}, so the diagonal estimate is unbiased there [58]. The resulting point estimate and its variance are

P^n^(f)=[Γn^n^(f)]−1Xn^(f),σn^2(f)=[Γn^n^(f)]−1,(8)\hat P_{\hat n}(f)=\left[\Gamma_{\hat n\hat n}(f)\right]^{-1}X_{\hat n}(f),\qquad\sigma_{\hat n}^{2}(f)=\left[\Gamma_{\hat n\hat n}(f)\right]^{-1}, \tag*{(8)}

with no summation over n^\hat n. The detection statistic is the signal-to-noise ratio (SNR)

ρ^n^(f)≡P^n^(f)σn^(f).(9)\hat\rho_{\hat n}(f)\equiv\frac{\hat P_{\hat n}(f)}{\sigma_{\hat n}(f)}. \tag*{(9)}

Effective strain and null-hypothesis testing

For nearly monochromatic CW signals, the ASAF search reports the measured cross-correlated power as an effective strain amplitude [52, 53, 54],

heff(f,n^)=P^n^(f) Δf.(10)h_{\mathrm{eff}}(f,\hat n)=\sqrt{\hat P_{\hat n}(f)\,\Delta f}. \tag*{(10)}

This is the strain that a circularly polarized, face-on source would need in order to produce the observed power. The conversion between radiometer quantities and the CW strain amplitude was developed for the radiometer searches directed at Scorpius X-1 [76, 77, 78]. It equals the intrinsic amplitude h0h_0 only if the signal is circularly polarized and confined to a single frequency bin [52, 53, 54]. The second condition fails at high frequency. The annual Doppler modulation of the source frequency by the motion of the Earth, of order ±10−4f\pm10^{-4}f, exceeds one 1/321/32 Hz bin above roughly 160 Hz and spreads a line over neighboring bins [54]. Intrinsic spin-down does the same once ∣f˙∣≳Δf/Tobs≃1.4×10−9 Hz s−1|\dot f|\gtrsim\Delta f/T_{\mathrm{obs}}\simeq1.4\times10^{-9}\ \mathrm{Hz}\ \mathrm{s}^{-1} for an O2-length run, far above the rates of the injections used here. This spectral spreading is independent of the source orientation. We do not correct for it, but estimate its effect on the injections in § 2 A. The first condition is the subject of this paper. A CW source has a polarization state set by its orientation, and the relation between heffh_{\mathrm{eff}} and h0h_0 is then given by the projection factor μ2\mu^2 derived in Sec. III C.

Under the null hypothesis the data contain only noise, for which ρ^\hat\rho would follow a zero-mean, unit-variance Gaussian distribution. Detector data, however, contain non-Gaussian artifacts such as narrowband spectral lines and glitches [87, 88, 89, 90], so the null distribution is obtained with the random time-shift method [53]. The run is divided into segments of a few thousand seconds, and in each segment the data of one detector are shifted by a random delay of 1 to 2 s. The delay is much longer than the 10 ms light travel time between the sites and differs between segments, so any persistent GW signal loses its coherence and only the noise background remains [49, 53]. The zero-lag data, without the time shift, are then tested against this distribution. The highest zero-lag SNR across all frequency-pixel pairs is assigned a local pp-value p1p_1, which is converted into a global one with Šidák’s correction [91], pG=1−(1−p1)Ntrialsp_G=1-(1-p_1)^{N_{\mathrm{trials}}}, to account for the many pairs tested. The null hypothesis is rejected if pG<0.05p_G<0.05, which corresponds to the SNR threshold

ρthr=2 erfc⁡−1(2p1),p1=1−(1−pG)1/Ntrials.(11)\rho_{\mathrm{thr}}=\sqrt{2}\,\operatorname{erfc}^{-1}(2p_1),\qquad p_1=1-(1-p_G)^{1/N_{\mathrm{trials}}}. \tag*{(11)}

With Nside=16N_{\mathrm{side}}=16 (Npix=3072N_{\mathrm{pix}}=3072) and Nfreq=54 593N_{\mathrm{freq}}=54\,593 frequency bins, Ntrials≃1.68×108N_{\mathrm{trials}}\simeq1.68\times10^8, the total number of frequency-pixel pairs. Setting pG=0.05p_G=0.05 gives ρthr=6.19\rho_{\mathrm{thr}}=6.19, which we adopt throughout. Sub-threshold candidates are identified by retaining the highest-SNR pixel at each frequency. Each is compared to the time-shifted distribution within the same 10 Hz sub-band, and those above the 99th percentile are selected for further investigation [53, 54, 61].

Continuous-wave sources and the orientation bias factor

The ASAF statistic of Sec. II is built on the SGWB formalism, which assumes an unpolarized signal [21, 22]. A CW source differs in two ways. It is a quasi-monochromatic, coherent signal with a definite phase evolution [69, 73, 74], and it emits in a polarization state fixed by its inclination and polarization angle. The first difference determines the response of a baseline to the source, and the second produces the orientation bias. In Sec. III A we define the CW signal model, in Sec. III B we give the baseline response, in Sec. III C we define the projection factor μ2(ι,ψ)\mu^2(\iota,\psi) and derive its orientation dependence, and in Sec. III D we propagate it to the quantities reported by the search.

Continuous-wave signal model

We consider a deformed rotating neutron star at a distance DD from Earth with equatorial ellipticity ϵ\epsilon. Its time-varying quadrupole moment emits gravitational radiation at twice the rotation frequency, f0=2frotf_0=2f_{\mathrm{rot}}, with intrinsic strain amplitude [16, 17, 69] [19]

h0=4π2GIzzϵf02c4D,(12)h_0=\frac{4\pi^2 G I_{zz}\epsilon f_0^2}{c^4D}, \tag*{(12)}

where IzzI_{zz} is the moment of inertia about the rotation axis. The source orientation is described by the inclination ι\iota and the polarization angle ψ\psi, which set the relative amplitudes of the two GW polarizations [69, 70, 72]

A+=12(1+cos⁡2ι)h0≡A+(ι)h0,A_+=\frac{1}{2}(1+\cos^2\iota)h_0\equiv\mathcal{A}_+(\iota)h_0,
A×=cos⁡ιh0≡A×(ι)h0.(13)A_\times=\cos\iota h_0\equiv\mathcal{A}_\times(\iota)h_0. \tag*{(13)}

A face-on source (ι=0\iota=0) has A+=A×=1A_+=A_\times=1 and emits circularly polarized radiation. An edge-on source (ι=π/2\iota=\pi/2) has A×=0A_\times=0 and A+=1/2A_+=1/2, producing linearly polarized emission. Each detector responds to the incoming GW through its antenna pattern functions, which separate the sky-position dependence from the polarization-angle dependence [69],

Fi+(n^,t;ψ)=ai(n^,t)cos⁡2ψ−bi(n^,t)sin⁡2ψ,(14)F_i^{+}(\hat{n},t;\psi)=a_i(\hat{n},t)\cos2\psi-b_i(\hat{n},t)\sin2\psi, \tag*{(14)}
Fi×(n^,t;ψ)=ai(n^,t)sin⁡2ψ+bi(n^,t)cos⁡2ψ,(15)F_i^{\times}(\hat{n},t;\psi)=a_i(\hat{n},t)\sin2\psi+b_i(\hat{n},t)\cos2\psi, \tag*{(15)}

where the beam-pattern coefficients depend only on the source direction,

ai(n^,t)=12(1+cos⁡2θ)cos⁡2ϕ,(16)a_i(\hat{n},t)=\frac{1}{2}(1+\cos^2\theta)\cos2\phi, \tag*{(16)}
bi(n^,t)=cos⁡θsin⁡2ϕ.(17)b_i(\hat{n},t)=\cos\theta\sin2\phi. \tag*{(17)}

Here θ\theta and ϕ\phi are the polar and azimuthal angles of the source direction n^\hat{n} in the frame of detector ii at time tt, which change over time as the Earth rotates. The detector tensor is diab=(u^au^b−v^av^b)/2d_i^{ab}=(\hat{u}^a\hat{u}^b-\hat{v}^a\hat{v}^b)/2, so that diabhabd_i^{ab}h_{ab} is the fractional change in arm length and ∣Fi+,×∣≤1\lvert F_i^{+,\times}\rvert\leq1 [92].

Cross-correlation response for a CW source

The response of a baseline to a CW source was derived in Refs. [73, 74]. We summarize it here and give the derivation in Appendix A. Let I1I_1 and I2I_2 denote the two detectors of baseline II, so that FiAF_i^{A} is Eq. (14) or Eq. (15) evaluated in the frame of that detector. The strain induced in detector IiI_i by the CW source of Sec. III A is

hIi(t)=A+FIi+(n^,t;ψ)cos⁡ΦIi(t;Λ)+A×FIi×(n^,t;ψ)sin⁡ΦIi(t;Λ).(18)h_{I_i}(t)=A_{+}F_{I_i}^{+}(\hat{n},t;\psi)\cos\Phi_{I_i}(t;\Lambda) +A_{\times}F_{I_i}^{\times}(\hat{n},t;\psi)\sin\Phi_{I_i}(t;\Lambda). \tag*{(18)}

The phase measured at the detector, ΦIi(t;Λ)\Phi_{I_i}(t;\Lambda), combines an intrinsic evolution set by f0f_0 and f˙0\dot{f}_0 with a Doppler term fixed by the detector position x⃗Ii(t)\vec{x}_{I_i}(t) relative to the solar system barycenter [18, 69]. For an isolated source, the signal is described by the amplitude h0h_0 and the parameters Λ={n^,f0,f˙0,ι,ψ,Φ0}\Lambda=\{\hat{n},f_0,\dot{f}_0,\iota,\psi,\Phi_0\}, with Φ0\Phi_0 the initial phase. A source in a binary also requires the orbital parameters.

Within an SFT of duration T=192T=192 s the signal is monochromatic to a good approximation, so its SFT consists of two narrow lines at ±f0(t)\pm f_0(t) (Appendix A). At the positive-frequency line, the product of the two signal SFTs entering the CSD of Eq. (2) is

h~I1∗(t;f)h~I2(t;f)=14h02GI(t;Λ)δT2(f−f0(t)),(19)\tilde{h}_{I_1}^{*}(t;f)\tilde{h}_{I_2}(t;f)=\frac{1}{4}h_0^2G_I(t;\Lambda)\delta_T^2(f-f_0(t)), \tag*{(19)}

where δT\delta_T is the finite-time Dirac delta of Eq. (57), and the complex baseline response function is [73, 74]

GI(t;Λ)=[A+FI1+(n^,t;ψ)+iA×FI1×(n^,t;ψ)][A+FI2+(n^,t;ψ)−iA×FI2×(n^,t;ψ)]eiΔΦI(t).(20)G_I(t;\Lambda)=\left[A_{+}F_{I_1}^{+}(\hat{n},t;\psi)+iA_{\times}F_{I_1}^{\times}(\hat{n},t;\psi)\right] \left[A_{+}F_{I_2}^{+}(\hat{n},t;\psi)-iA_{\times}F_{I_2}^{\times}(\hat{n},t;\psi)\right]e^{i\Delta\Phi_I(t)}. \tag*{(20)}

The amplitude factors out as h02h_0^2, so GIG_I depends only on the geometry and the orientation. The source phase cancels between the two detectors, and ΔΦI(t)=2πfn^⋅Δx⃗I(t)/c\Delta\Phi_I(t)=2\pi f\hat{n}\cdot\Delta\vec{x}_I(t)/c is the geometric delay of the ORF of Eq. (4). We now fix the baseline and the sky direction, write F1,2AF_{1,2}^{A} for FI1,2A(n^,t;ψ)F_{I_{1,2}}^{A}(\hat{n},t;\psi), and carry the remaining time dependence in the subscript of GtG_t. We write γt\gamma_t for the point-source ORF of Eq. (4) reduced the same way. The phase-delay factor eiΔΦI(t)e^{i\Delta\Phi_I(t)} is common to GtG_t and γt\gamma_t, so it cancels in the projection factor defined below and we drop it from both. Then γt=F1+F2++F1×F2×\gamma_t=F_1^{+}F_2^{+}+F_1^{\times}F_2^{\times} is real, and the instantaneous response is

Gt(ι,ψ)=[A+F1++iA×F1×][A+F2+−iA×F2×].(21)G_t(\iota,\psi)=\left[A_{+}F_1^{+}+iA_{\times}F_1^{\times}\right]\left[A_{+}F_2^{+}-iA_{\times}F_2^{\times}\right]. \tag*{(21)}

Its real part, which is the part retained by the estimator of Sec. II D, is

Re⁡Gt=A+2F1+F2++A×2F1×F2×.(22)\operatorname{Re}G_t=A_{+}^{2}F_1^{+}F_2^{+}+A_{\times}^{2}F_1^{\times}F_2^{\times}. \tag*{(22)}

The cross terms, proportional to A+A×A_{+}A_{\times}, are purely imaginary and drop out. The ORF weights the two polarization products equally, whereas Re⁡Gt\operatorname{Re}G_t weights them by A+2A_{+}^{2} and A×2A_{\times}^{2}. The two coincide only if A+2=A×2A_{+}^{2}=A_{\times}^{2}, that is, for cos⁡ι=±1\cos\iota=\pm1.

The projection factor μ2\mu^2

For a CW source with known parameters, the optimal estimator of H=h02\mathcal{H}=h_0^2 uses GIG_I in place of γI\gamma^I as the template [73, 74], H^=ΓCW−1XCW\widehat{\mathcal{H}}=\Gamma_{\rm CW}^{-1}X_{\rm CW}, with

XCW(f)∝Re⁡∑I,tCI(t;f)GI∗(t;Λ)δT2(f−f0(t))PI1(t;f)PI2(t;f),(23)X_{\rm CW}(f)\propto\operatorname{Re}\sum_{I,t}\frac{C^I(t;f)G_I^{*}(t;\Lambda)\delta_T^2(f-f_0(t))}{P_{I_1}(t;f)P_{I_2}(t;f)}, \tag*{(23)}
ΓCW(f)∝∑I,t∣GI(t;Λ)∣2δT2(f−f0(t))PI1(t;f)PI2(t;f),(24)\Gamma_{\rm CW}(f)\propto\sum_{I,t}\frac{\lvert G_I(t;\Lambda)\rvert^2\delta_T^2(f-f_0(t))}{P_{I_1}(t;f)P_{I_2}(t;f)}, \tag*{(24)}

and variance ΓCW−1\Gamma_{\rm CW}^{-1}. This matched filter recovers h02h_0^2 at any orientation, but requires a bank of templates over (n^,f0,f˙0,ι,ψ)(\hat{n},f_0,\dot{f}_0,\iota,\psi). The ASAF search uses the orientation-independent template γI\gamma^I instead, with a single template per sky pixel and frequency bin.

Applying the pixel estimator of Eq. (8) to the CW signal gives the projection factor, called the bias factor in Ref. [78],

μ2(ι,ψ)=∑twtγtRe⁡Gt(ι,ψ)∑twtγt2,wt=1P1(t;f)P2(t;f).(25)\mu^2(\iota,\psi)=\frac{\sum_t w_t\gamma_t\operatorname{Re}G_t(\iota,\psi)}{\sum_t w_t\gamma_t^2},\qquad w_t=\frac{1}{P_1(t;f)P_2(t;f)}. \tag*{(25)}

The numerator is the dirty map of Eq. (6) evaluated on the CW signal, which is proportional to GtG_t, and the denominator is the Fisher element of Eq. (7). With the normalization of Sec. II D, which absorbs the factor 1/41/4 and the factor δT2\delta_T^2, a line confined to a single bin gives P^=μ2h02/Δf\widehat{\mathcal{P}}=\mu^2h_0^2/\Delta f, so that heff=μ2h0h_{\rm eff}=\sqrt{\mu^2}h_0 in Eq. (10). The projection factor is therefore the ratio of the effective to the intrinsic strain power, μ2=heff2/h02\mu^2=h_{\rm eff}^2/h_0^2. For a face-on source Re⁡Gt=γt\operatorname{Re}G_t=\gamma_t and μ2=1\mu^2=1 exactly. Since Re⁡Gt\operatorname{Re} G_t depends on ι\iota only through A+2A_{+}^{2} and A×2A_{\times}^{2}, which are even in cos⁡ι\cos\iota, μ2(π−ι,ψ)=μ2(ι,ψ)\mu^{2}(\pi-\iota,\psi)=\mu^{2}(\iota,\psi), and we restrict to cos⁡ι∈[0,1]\cos\iota\in[0,1]. The results below hold for any positive weights. In our numerical evaluations we take wtw_t uniform over the sidereal day. For folded data this is a good approximation, because the daily variations of the detector noise follow solar rather than sidereal time and average out over a run of many months.

A simple limit illustrates the orientation dependence. For co-aligned detectors with the source at the zenith (ai=1a_i=1, bi=0b_i=0), the antenna patterns reduce to Fi+=cos⁡2ψF_i^{+}=\cos2\psi and Fi×=sin⁡2ψF_i^{\times}=\sin2\psi, so γt=1\gamma_t=1 and Eq. (22) gives

μ2∣zen=A+2cos⁡22ψ+A×2sin⁡22ψ.(26)\left.\mu^{2}\right|_{\mathrm{zen}}=A_{+}^{2}\cos^{2}2\psi+A_{\times}^{2}\sin^{2}2\psi. \tag*{(26)}

Averaging over ψ\psi, uniformly distributed over one period [−π/4,π/4][-\pi/4,\pi/4], gives

⟨μ2⟩ψ=1+6cos⁡2ι+cos⁡4ι8,(27)\langle\mu^{2}\rangle_{\psi}=\frac{1+6\cos^{2}\iota+\cos^{4}\iota}{8}, \tag*{(27)}

the orientation factor commonly used in CW sensitivity estimates [69], which falls from 1 at ι=0\iota=0 to 1/81/8 at ι=π/2\iota=\pi/2. Averaging further over cos⁡ι\cos\iota uniformly distributed in [0,1][0,1], which corresponds to isotropically oriented sources, yields

⟨μ2⟩ι,ψ=25=0.40.(28)\langle\mu^{2}\rangle_{\iota,\psi}=\frac{2}{5}=0.40 . \tag*{(28)}

For randomly oriented sources, heff2h_{\mathrm{eff}}^{2} is therefore on average 40% of h02h_{0}^{2}, and heffh_{\mathrm{eff}} underestimates h0h_{0} by a factor 5/2≈1.58\sqrt{5/2}\approx1.58.

Using Eqs. (14) and (15), the two polarization products can be written as (Appendix B)

F1+F2++F1×F2×=a1a2+b1b2≡At,(29)F_{1}^{+}F_{2}^{+}+F_{1}^{\times}F_{2}^{\times}=a_{1}a_{2}+b_{1}b_{2}\equiv A_t , \tag*{(29)}
F1+F2+−F1×F2×=Ct(1)cos⁡4ψ−Ct(2)sin⁡4ψ,(30)F_{1}^{+}F_{2}^{+}-F_{1}^{\times}F_{2}^{\times}=C_{t}^{(1)}\cos4\psi-C_{t}^{(2)}\sin4\psi, \tag*{(30)}

with Ct(1)=a1a2−b1b2C_{t}^{(1)}=a_{1}a_{2}-b_{1}b_{2} and Ct(2)=a1b2+a2b1C_{t}^{(2)}=a_{1}b_{2}+a_{2}b_{1}. The sum is γt\gamma_t and carries no ψ\psi, and the difference carries all of it. Summing over the sidereal day with the weights wtw_t leaves three numbers,

D=∑twtAt2,C(1)=∑twtAtCt(1),D=\sum_t w_t A_t^{2},\qquad C^{(1)}=\sum_t w_t A_t C_t^{(1)},
C(2)=∑twtAtCt(2),(31)C^{(2)}=\sum_t w_t A_t C_t^{(2)}, \tag*{(31)}

which define the depth and phase of the ψ\psi modulation,

ϵ=(C(1))2+(C(2))2D,δ=atan2⁡(C(2),C(1)).(32)\epsilon=\frac{\sqrt{\left(C^{(1)}\right)^{2}+\left(C^{(2)}\right)^{2}}}{D},\qquad\delta=\operatorname{atan2}\left(C^{(2)},C^{(1)}\right). \tag*{(32)}

Inserting Eqs. (29) and (30) into Eq. (25) gives the exact closed form

μ2(ι,ψ)=A+2+A×22+A+2−A×22ϵcos⁡(4ψ+δ).(33)\mu^{2}(\iota,\psi)=\frac{A_{+}^{2}+A_{\times}^{2}}{2}+\frac{A_{+}^{2}-A_{\times}^{2}}{2}\epsilon\cos(4\psi+\delta). \tag*{(33)}

The first term depends only on the inclination. The second term carries all the dependence on ψ\psi, as a single harmonic in 4ψ4\psi. The parameters ϵ\epsilon and δ\delta are not free. They are fixed by the baseline geometry, and with uniform weights they are independent of frequency and depend only on the declination of the source (Appendix B). At edge-on inclination μ2=(1+ϵcos⁡(4ψ+δ))/8\mu^{2}=(1+\epsilon\cos(4\psi+\delta))/8, so ϵ\epsilon is the relative depth of the ψ\psi modulation and δ\delta locates its maximum. The zenith limit of Eq. (26) corresponds to ϵ=1\epsilon=1, δ=0\delta=0. The modulation is not negligible. Its depth reaches ϵ=0.39\epsilon=0.39 at declinations near ±19.5∘\pm19.5^\circ.

Equation (33) has three exact consequences. First, Eq. (27) holds for the full time-dependent statistic at any sky position and for any noise weighting, so the zenith limit is not needed. Second, integrating over cos⁡ι\cos\iota reproduces Eq. (28) independent of geometry, weighting, and frequency. Third, provided ϵ≤1\epsilon\leq1, the global minimum lies at edge-on inclination,

μmin⁡2=1−ϵ8atψ∗=π−δ4(modπ/2),(34)\mu_{\min}^{2}=\frac{1-\epsilon}{8}\quad\text{at}\quad\psi^{*}=\frac{\pi-\delta}{4}\pmod{\pi/2}, \tag*{(34)}

which tends to 1/81/8 near the celestial poles, where ϵ→0\epsilon\to0 because the rotation of the Earth sweeps the polarization angle uniformly over a day. The bound ϵ≤1\epsilon\leq1 is verified numerically for the O2 HL-L1 baseline in Appendix B.

Finally, Eq. (33) fixes the largest inclination at which a source remains detectable. Requiring max⁡ψμ2=ρthr/ρref\max_{\psi}\mu^{2}=\rho_{\mathrm{thr}}/\rho_{\mathrm{ref}} gives

(1+ϵ)u2+(6−2ϵ)u+(1+ϵ−8m)=0,(35)(1+\epsilon)u^{2}+(6-2\epsilon)u+(1+\epsilon-8m)=0, \tag*{(35)}

where u=cos⁡2ιu=\cos^{2}\iota and m=ρthr/ρrefm=\rho_{\mathrm{thr}}/\rho_{\mathrm{ref}}. Its root u∈[0,1]u\in[0,1] gives the largest inclination detectable at the most favorable ψ\psi. At ϵ=0\epsilon=0 it reduces to ⟨μ2⟩ψ=m\langle\mu^{2}\rangle_{\psi}=m, with ⟨μ2⟩ψ\langle\mu^{2}\rangle_{\psi} of Eq. (27). Table I summarizes the comparison between the stochastic and CW formalisms.

PropertySGWB (assumed)CW (actual)
Signal typerandom fielddeterministic waveform [Eq. (18)]
Polarization contentequal, uncorrelated power in + and ×fixed by (ι,ψ)(\iota,\psi) [Eq. (13)]
Baseline responseORF γI\gamma^{I} [Eq. (4)]complex GIG_{I} [Eq. (20)]
Optimal filterγI\gamma^{I}GIG_{I} [Eq. (23)]
Filter used by the radiometerγI\gamma^{I}γI\gamma^{I} (not matched to GIG_{I})
Polarization weightingequal weight for + and ×A+2\mathcal{A}_{+}^{2} and A×2\mathcal{A}_{\times}^{2}
Recovered quantityangular power P(f,n^)P(f,\hat{n})μ2h02/Δf\mu^{2}h_{0}^{2}/\Delta f
SNR relative to a face-on source with the same h0h_{0}unchangedreduced by μ2\mu^{2}, with μ2=1\mu^{2}=1 only face-on

Table I. Comparison between the stochastic-background and continuous-wave cross-correlation formalisms. The equal-weight statistic is designed for the SGWB case. Applied to a CW source, it returns heff2=μ2h02h_{\mathrm{eff}}^{2}=\mu^{2}h_{0}^{2}.

Orientation bias propagation

The projection factor μ2\mu^{2} enters every physical quantity the search reports. Three SNRs appear in what follows. They describe the same source in the same data and differ only in the orientation at which μ2\mu^{2} is evaluated.

  • Measured SNR, ρ^\hat{\rho}. The SNR computed by the ASAF search, Eq. (9). It corresponds to the true orientation of the source, known for a hardware injection and unknown for a search candidate. The orientation suppression is therefore already contained in ρ^\hat{\rho} and cannot be read off from it. Its null distribution calibrates the threshold ρthr\rho_{\mathrm{thr}} of Eq. (11).

  • Recovered SNR, ρrec(ι,ψ)\rho_{\mathrm{rec}}(\iota,\psi). The SNR the same source would produce at an arbitrary orientation. It is a surface over the orientation plane, highest face-on, and ρ^\hat{\rho} is its value at the true orientation.

  • Reference SNR, ρref\rho_{\mathrm{ref}}. This is the peak of that surface, at μ2=1\mu^{2}=1, that is, the SNR of a face-on source with the same h0h_{0}. It depends only on the intrinsic strength of the source and the detector noise, not on how the source is tilted. Two sources with the same h0h_{0} therefore have the same ρref\rho_{\mathrm{ref}}, whatever their orientation.

a. Strain. The intrinsic and effective strain amplitudes are related by

h0=heffμ2.(36)h_{0} = \frac{h_{\mathrm{eff}}}{\sqrt{\mu^{2}}}. \tag*{(36)}

b. Signal-to-noise ratio. Because the radiometer estimates signal power, the recovered SNR is linear in μ2\mu^{2},

ρrec(ι,ψ)=μ2(ι,ψ) ρref.(37)\rho_{\mathrm{rec}(\iota,\psi)} = \mu^{2}(\iota,\psi)\,\rho_{\mathrm{ref}}. \tag*{(37)}

Since μ2≤1\mu^{2}\leq1, ρ^≤ρref\hat{\rho}\leq\rho_{\mathrm{ref}}, with equality only for a face-on source. Because published ASAF analyses report only ρ^\hat{\rho}, a low value is ambiguous between an intrinsically weak source and a strong one at an unfavorable orientation. When the orientation is known, the projection factor separates the two. For a PHWI the measured SNR is ρ^=μinj2ρref\hat{\rho}=\mu_{\mathrm{inj}}^{2}\rho_{\mathrm{ref}}, which inverts to ρref=ρ^/μinj2\rho_{\mathrm{ref}}=\hat{\rho}/\mu_{\mathrm{inj}}^{2}. Since the measured statistic has unit variance, the noise uncertainty on the inferred reference SNR is σ(ρref)=1/μinj2\sigma(\rho_{\mathrm{ref}})=1/\mu_{\mathrm{inj}}^{2}, and this is the error bar quoted throughout.

c. Upper limits. An upper limit on the effective strain translates into a weaker limit on the intrinsic amplitude,

h0UL=heffULμ2≥heffUL,(38)h_{0}^{\mathrm{UL}} = \frac{h_{\mathrm{eff}}^{\mathrm{UL}}}{\sqrt{\mu^{2}}} \geq h_{\mathrm{eff}}^{\mathrm{UL}}, \tag*{(38)}

with equality only for a face-on source.

d. Detection probability. With unit-variance noise on the recovered SNR, the probability of exceeding the threshold ρthr\rho_{\mathrm{thr}} is

Pdet(ι,ψ)=12erfc⁡(ρthr−μ2ρref2).(39)P_{\mathrm{det}}(\iota,\psi) = \frac{1}{2}\operatorname{erfc}\left(\frac{\rho_{\mathrm{thr}}-\mu^{2}\rho_{\mathrm{ref}}}{\sqrt{2}}\right). \tag*{(39)}

We summarize this by the detectability ratio

R(ι,ψ)≡μ2(ι,ψ)ρrefρthr.(40)\mathcal{R}(\iota,\psi) \equiv\frac{\mu^{2}(\iota,\psi)\rho_{\mathrm{ref}}}{\rho_{\mathrm{thr}}}. \tag*{(40)}

R≥1\mathcal{R}\geq1 means that the mean recovered SNR reaches the threshold, equivalently Pdet≥1/2P_{\mathrm{det}}\geq1/2. We adopt this as the detection criterion and call orientations with R<1\mathcal{R}<1 missed.

e. Orientation completeness. For a source of given ρref\rho_{\mathrm{ref}}, the orientation completeness is the fraction of isotropically distributed orientations at which the source would be detected,

C=2π∫01dcos⁡ι∫−π/4π/4dψ Θ(R(ι,ψ)−1),(41)\mathcal{C} = \frac{2}{\pi}\int_{0}^{1} d\cos\iota\int_{-\pi/4}^{\pi/4} d\psi\ \Theta(\mathcal{R}(\iota,\psi)-1), \tag*{(41)}

where Θ\Theta is the step function. By the symmetry ι→π−ι\iota\to\pi-\iota and the period π/2\pi/2 of Eq. (33) in ψ\psi, this range covers all orientations. We evaluate the integral on the centers of N=10×10N=10\times10 equal cells in (cos⁡ι,ψ)(\cos\iota,\psi), so that C=Ndet/N\mathcal{C}=N_{\mathrm{det}}/N, with NdetN_{\mathrm{det}} the number of cells with R≥1\mathcal{R}\geq1.

Orientation-marginalized upper limits

In the absence of a detection, the ASAF search sets Bayesian ULs on heffh_{\rm eff}. These are limits on h0h_0 only for a circularly polarized source, μ2=1\mu^2=1. For a source of unknown orientation, the limit must be marginalized over orientation. We follow the procedure of the published ASAF analyses [53, 54] and extend it with the substitution heff2→μ2(ι,ψ)h02h_{\rm eff}^2 \to\mu^2(\iota,\psi)h_0^2 of Sec. III C. The same marginalization has been applied in directed radiometer searches [54, 76, 78].

Bayesian upper limits under the face-on assumption

We adopt the hybrid frequentist-Bayesian approach of Refs. [53, 54, 93]. The point estimate of Eq. (8) is treated as a sufficient statistic, and Bayes’ theorem gives the posterior of the strain amplitude. We absorb the bin width into the estimators,

P^≡P^n^(f) Δf,σP≡σn^(f) Δf,(42)\hat{\mathcal{P}} \equiv\hat{P}_{\hat{n}}(f)\,\Delta f,\qquad\sigma_{\mathcal{P}} \equiv\sigma_{\hat{n}}(f)\,\Delta f, \tag*{(42)}

so that heff2=P^h_{\rm eff}^2=\hat{\mathcal{P}} and ρ^=P^/σP\hat{\rho}=\hat{\mathcal{P}}/\sigma_{\mathcal{P}}. The 95% credible upper limit is defined by

0.95=∫0heffULdheff L(P^∣heff)p(heff)∫0hmax⁡dh L(P^∣h)p(h),(43)0.95=\int_0^{h_{\rm eff}^{\rm UL}} \mathrm{d}h_{\rm eff}\,\frac{\mathcal{L}(\hat{\mathcal{P}}\mid h_{\rm eff})p(h_{\rm eff})}{\int_0^{h_{\max}}\mathrm{d}h\,\mathcal{L}(\hat{\mathcal{P}}\mid h)p(h)}, \tag*{(43)}

where L\mathcal{L} is the likelihood and pp the prior.

The likelihood is Gaussian. The noise has variance σP2\sigma_{\mathcal{P}}^2. The amplitude calibration of the detectors multiplies the signal power by an unknown factor λ\lambda [54, 94],

P^=λheff2+n,n∼N(0,σP2),λ∼N(1,σλ2).(44)\hat{\mathcal{P}}=\lambda h_{\rm eff}^2+n,\qquad n\sim\mathcal{N}(0,\sigma_{\mathcal{P}}^2),\qquad\lambda\sim\mathcal{N}(1,\sigma_\lambda^2). \tag*{(44)}

Marginalizing over λ\lambda adds σλ2heff4\sigma_\lambda^2h_{\rm eff}^4 to the variance,

L(P^∣heff)=12π(σP2+σλ2heff4)exp⁡[−(P^−heff2)22(σP2+σλ2heff4)].(45)\mathcal{L}(\hat{\mathcal{P}}\mid h_{\rm eff})=\frac{1}{\sqrt{2\pi\left(\sigma_{\mathcal{P}}^2+\sigma_\lambda^2h_{\rm eff}^4\right)}}\exp\left[-\frac{\left(\hat{\mathcal{P}}-h_{\rm eff}^2\right)^2}{2\left(\sigma_{\mathcal{P}}^2+\sigma_\lambda^2h_{\rm eff}^4\right)}\right]. \tag*{(45)}

Here σλ2=σH2+σL2+σH2σL2\sigma_\lambda^2=\sigma_H^2+\sigma_L^2+\sigma_H^2\sigma_L^2 combines the calibration uncertainties of the two detectors. With σH=0.026\sigma_H=0.026 and σL=0.0385\sigma_L=0.0385 for O2, and 0.06930.0693 and 0.0410.041 for O4a [54, 95], we obtain σλ=0.0465\sigma_\lambda=0.0465 and 0.08060.0806.

We adopt the uniform prior heff∼U[0,hmax⁡]h_{\rm eff}\sim\mathcal{U}[0,h_{\max}] of the published analyses [53, 54], with

hmax⁡=10σP.(46)h_{\max}=10\sqrt{\sigma_{\mathcal{P}}}. \tag*{(46)}

The posterior is evaluated on 10410^4 uniform grid points over this range. The UL is the value of heffh_{\rm eff} at which the normalized cumulative sum of the posterior reaches 0.95. We use the same implementation throughout, so our circular limits for the O4a candidates reproduce the published ones [54].

We measure hh in units of the noise scale, x=h/σPx=h/\sqrt{\sigma_{\mathcal{P}}}. In these units σP\sigma_{\mathcal{P}} drops out of the posterior, which then depends only on ρ^\hat{\rho} and σλ\sigma_\lambda. The UL is therefore

heffUL=σP g(ρ^,σλ),(47)h_{\rm eff}^{\rm UL}=\sqrt{\sigma_{\mathcal{P}}}\,g(\hat{\rho},\sigma_\lambda), \tag*{(47)}

where gg is the UL on xx.

Extension to a source of arbitrary orientation

A CW source of amplitude h0h_0 at orientation (ι,ψ)(\iota,\psi) produces the cross-power μ2h02\mu^2h_0^2. The calibration factor multiplies this power, and the noise is unchanged. Replacing heff2h_{\rm eff}^2 by μ2h02\mu^2h_0^2 in Eq. (45) gives

L(P^∣h0,ι,ψ)=12π(σP2+σλ2μ4h04)exp⁡[−(P^−μ2h02)22(σP2+σλ2μ4h04)].(48)\mathcal{L}(\hat{\mathcal{P}}\mid h_0,\iota,\psi)=\frac{1}{\sqrt{2\pi\left(\sigma_{\mathcal{P}}^2+\sigma_\lambda^2\mu^4h_0^4\right)}}\exp\left[-\frac{\left(\hat{\mathcal{P}}-\mu^2h_0^2\right)^2}{2\left(\sigma_{\mathcal{P}}^2+\sigma_\lambda^2\mu^4h_0^4\right)}\right]. \tag*{(48)}

The orientation enters only through μ2h02\mu^2h_0^2. We consider three prescriptions.

The circular prescription, used by ASAF, sets μ2=1\mu^2=1. It gives the UL of Sec. IV A.

The at-target prescription fixes μ2\mu^2 at a known orientation. The likelihood is then the circular one at heff=μ2h0h_{\rm eff}=\sqrt{\mu^2}h_0. The posterior, its prior range, and its 95% quantile are all stretched by 1/μ21/\sqrt{\mu^2}, so

h0UL(ι,ψ)=heffULμ2(ι,ψ).(49)h_0^{\rm UL}(\iota,\psi)=\frac{h_{\rm eff}^{\rm UL}}{\sqrt{\mu^2(\iota,\psi)}}. \tag*{(49)}

as in Eq. (38). We use it for the hardware injections, whose orientations are known, and to bound the UL of a candidate over all orientations.

The marginalized prescription treats the orientation as unknown. The priors are uniform in cos⁡ι∈[0,1]\cos\iota\in[0,1] and ψ∈[−π/4,π/4]\psi\in[-\pi/4,\pi/4], which covers all orientations (Sec. III C), and uniform in h0∈[0,h0gen]h_0\in[0,h_0^{\rm gen}]. The posterior is

pgen(h0∣P^)∝∫01d(cos⁡ι)∫−π/4π/42 dψπ L(P^∣h0,ι,ψ),(50)p_{\rm gen}(h_0\mid\hat{\mathcal{P}})\propto\int_0^1\mathrm{d}(\cos\iota)\int_{-\pi/4}^{\pi/4}\frac{2\,\mathrm{d}\psi}{\pi}\,\mathcal{L}(\hat{\mathcal{P}}\mid h_0,\iota,\psi), \tag*{(50)}

and the UL h0UL,genh_0^{\rm UL,gen} follows from Eq. (43). Since L\mathcal{L} depends on the orientation only through μ2\mu^2, the double integral reduces to an average over the prior distribution of μ2\mu^2. We evaluate Eq. (33) on a 1000×10001000\times1000 grid in (cos⁡ι,ψ)(\cos\iota,\psi) and histogram the values into 512 bins with centers μk2\mu_k^2 and weights wkw_k, ∑kwk=1\sum_k w_k=1. The posterior becomes

pgen(h0∣P^)∝∑kwkL(P^∣h0;μk2),(51)p_{\rm gen}(h_0\mid\hat{\mathcal{P}})\propto\sum_k w_k\mathcal{L}(\hat{\mathcal{P}}\mid h_0;\mu_k^2), \tag*{(51)}

a weighted sum of the likelihood of Eq. (48) over the orientation prior.

The prior range on h0h_0 requires care. An edge-on source must be intrinsically louder than a face-on one to produce the same cross-power. The posterior therefore extends to heff/μmin⁡2h_{\mathrm{eff}}/\sqrt{\mu_{\min}^2}, about three times the face-on scale. We take the range of the least favorable orientation,

hmax⁡gen=10σΓρμmin⁡2,(52)h_{\max}^{\mathrm{gen}} = \frac{10\sqrt{\sigma_\Gamma\rho}}{\sqrt{\mu_{\min}^2}}, \tag*{(52)}

with μmin⁡2\mu_{\min}^2 of Eq. (34).

Marginalized versus circular upper limits

The ratio h0UL,gen/h0UL,circh_0^{\mathrm{UL,gen}}/h_0^{\mathrm{UL,circ}} measures the cost of dropping the face-on assumption. With μ2\mu^2 fixed at its mean of 2/52/5, it would be 5/2≈1.58\sqrt{5/2} \approx1.58. The actual ratio is larger, because the 95% limit is set by the upper tail of the posterior. In Eq. (51), near-edge-on orientations stretch the circular posterior the most, by 1/μk21/\sqrt{\mu_k^2}, and with a uniform prior on h0h_0 they also carry the largest weight, wk/μk2w_k/\sqrt{\mu_k^2}.

The ratio is smallest for a pair consistent with noise, whose circular posterior is already broad. It grows with ρ^\hat{\rho} and with ϵ\epsilon, toward 1/μ521/\sqrt{\mu_5^2}, where μ52\mu_5^2 is the fifth percentile of μ2\mu^2 weighted by wk/μk2w_k/\sqrt{\mu_k^2}. The calibration uncertainty keeps it slightly below this value. The targeted narrowband radiometer of Ref. [54] reports a ratio of about 2.5, close to ours (§ 2 D and VI B). The closed form of Eq. (33) explains this ratio and extends the marginalization to every frequency-pixel pair of the ASAF search.

Application to O2 hardware injections

We now apply the formalism to four PHWIs injected during O2, with known source parameters [71, 96]. They lie at four sky positions, and their polarization ranges from nearly circular (face-on) to nearly linear (edge-on). We order them by decreasing ∣cos⁡ι∣\lvert\cos\iota\rvert.

Injection properties and measured quantities

All results use Nside=16N_{\mathrm{side}} = 16, ρthr=6.19\rho_{\mathrm{thr}} = 6.19, and σλ=0.0465\sigma_\lambda= 0.0465, the combined O2 amplitude calibration uncertainty of Sec. IV A. The injected orientations are known exactly from the hardware-injection parameter files [71]. The only systematic in μ2\mu^2 is therefore the use of the pixel center instead of the true source position. Its effect on μ2\mu^2 is negligible compared with the noise.

Table II collects the results. The four injections span the full range of polarization. Injection 1 is nearly face-on (∣cos⁡ι∣=0.988\lvert\cos\iota\rvert= 0.988) and circularly polarized. Injection 4 is nearly edge-on (∣cos⁡ι∣=0.081\lvert\cos\iota\rvert= 0.081) and linearly polarized. Injections 2 and 3 lie in between. The measured SNR follows the same order. It falls from ρ^=26.63\hat{\rho} = 26.63 for Injection 1 to ρ^=5.20\hat{\rho} = 5.20 for Injection 4, which is below threshold. The projection factor explains this difference: μ2=0.976\mu^2 = 0.976 for Injection 1, but only 0.167 for Injection 4. Dividing ρ^\hat{\rho} by μ2\mu^2 gives the face-on-equivalent SNRs ρref=27.3±1.0\rho_{\mathrm{ref}} = 27.3 \pm1.0, 45.2 ±\pm 2.3, 56.8 ±\pm 3.4, and 31.1 ±\pm 6.0 for Injections 1 to 4. Since ρ^\hat{\rho} has unit variance, σ(ρref)=1/μ2\sigma(\rho_{\mathrm{ref}}) = 1/\mu^2 (Sec. III D).

The injected amplitudes are also known, so μ2\mu^2 can be tested directly. Dividing heffh_{\mathrm{eff}} by μ2\sqrt{\mu^2} gives the recovered h0h_0 of Table II, with uncertainty from σ(heff)=heff/(2ρ^)\sigma(h_{\mathrm{eff}}) = h_{\mathrm{eff}}/(2\hat{\rho}). For Injections 1 and 3, the recovered h0h_0 agrees with the injected value. For Injections 2 and 4, it is lower by factors of 2.2 and 1.3. This deficit is not caused by the orientation. It comes from two known losses of cross-power in the analyzed bin:

  • Doppler loss. The orbital motion of the Earth spreads the line over neighboring bins. The line of Injection 4, at 108.857 Hz, lies only 2 mHz below the upper edge of its 1/32 Hz bin, so about 40% of its power moves into the next bin. Injection 2, at 763.85 Hz, loses about half of its power in the same way.

  • Pixel-phase loss. The radiometer phase is evaluated at the pixel center, 2.1° from Injection 2. This costs it about half of its remaining power.

Correcting for these losses gives h0≈2.9×10−24h_0 \approx2.9 \times10^{-24} for Injection 2 and 8.2×10−258.2 \times10^{-25} for Injection 4, close to the injected values. The losses lower ρ^\hat{\rho}, heffh_{\mathrm{eff}}, and the quantities derived from them. They do not change μ2\mu^2, or the ratios between the UL prescriptions of § 2 D.

Projection-factor maps

Figure 1 shows μ2(l,ψ)\mu^2(l,\psi) across the full orientation plane for Injections 3 and 4. The two panels differ in one aspect, the presence or absence of structure along the ψ\psi axis. Equation (33) explains this difference. Its first term depends only on ι\iota. The ψ\psi structure comes from the second term, whose depth ϵ\epsilon depends on the sky position, and with uniform weights only on the declination (Appendix B). A map shows ψ\psi structure only where the coefficients Ct(1)C_t^{(1)} and Ct(2)C_t^{(2)} do not cancel in the daily sums of Eq. (31), so that ϵ\epsilon is not small.

Figure 1. Projection factor μ2(ι,ψ)\mu^2(\iota,\psi) for Injection 3 (top, Dec =−83.84∘=-83.84^\circ, near the south celestial pole) and Injection 4 (bottom, Dec =−33.44∘=-33.44^\circ), on a common color scale. Markers show the face-on (circle), target (cross), and edge-on (square) orientations, and the minimum μmin⁡2=(1−ε)/8\mu_{\min}^2=(1-\varepsilon)/8 at ψ∗\psi^\ast (triangle). Injection 3 has ε≈10−3\varepsilon\approx10^{-3}, and its contours barely depend on ψ\psi. Injection 4 has ε=0.302\varepsilon=0.302, and its contours vary with ψ\psi. Both average to ⟨μ2⟩=2/5\langle\mu^2\rangle=2/5.

Injection 3 (top panel, RA = 20.2h^{\mathrm{h}}, Dec = −83.84∘-83.84^\circ) lies 6° from the south celestial pole. For a source at the pole, the rotation of the Earth turns both detectors about the line of sight. Over a sidereal day this sweeps the polarization angle seen by the detectors uniformly, and the modulation coefficients cancel in the sum. Here ϵ≈10−3\epsilon\approx10^{-3}. The modulation term of Eq. (33) then averages out, the contours become nearly horizontal bands that depend only on ι\iota, and the minimum μmin⁡2=0.125=1/8\mu_{\min}^2 = 0.125 = 1/8 is the analytic edge-on limit of Eq. (27).

Injection 4 (bottom panel, RA = 11.9h^{\mathrm{h}}, Dec = −33.44∘-33.44^\circ) lies at mid-declination. There the rotation of the Earth changes the projected detector geometry as well as the angle, and the coefficients cancel only in part. The modulation depth is ϵ=0.302\epsilon= 0.302, and the contours vary with ψ\psi with period π/2\pi/2. The minimum is μmin⁡2=(1−ϵ)/8=0.087\mu^2_{\min} = (1-\epsilon)/8 = 0.087, from Eq. (34). It lies below the ψ\psi-averaged edge-on value 1/81/8. The coefficients ϵ\epsilon and ψ∗\psi^* of all four injections are listed in Table III.

Inj. 1Inj. 2Inj. 3Inj. 4
ρref\rho_{\mathrm{ref}}27.3±1.027.3 \pm1.045.2±2.345.2 \pm2.356.8±3.456.8 \pm3.431.1±6.031.1 \pm6.0
ϵ\epsilon0.2020.0040.0010.302
ψ∗\psi^* [deg]−18.0-18.0−18.4-18.4−11.2-11.2+17.9+17.9
μmin⁡2\mu^2_{\min}0.1000.1250.1250.087
ρref,crit\rho_{\mathrm{ref,crit}}62.049.749.570.9
Edge-on ρrec\rho_{\mathrm{rec}}3.205.647.103.52
PdetP_{\mathrm{det}} at target1.0001.0001.0000.161
Edge-on PdetP_{\mathrm{det}}0.0010.2920.8200.004
C=Ndet/N\mathcal{C} = N_{\mathrm{det}}/N64/10090/100100/10070/100
ιmax⁡∃ψ\iota_{\max}^{\exists\psi}70.9∘70.9^\circ82.9∘82.9^\circ90.0∘90.0^\circ76.7∘76.7^\circ
R\mathcal{R} at target4.303.142.680.84

Table III. Detection statistics for the four O2 injections at ρthr=6.19\rho_{\mathrm{thr}} = 6.19. The coefficients ϵ\epsilon and ψ∗\psi^* are those of Eq. (33) at each sky position, μmin⁡2=(1−ϵ)/8\mu^2_{\min} = (1-\epsilon)/8 is the pointwise minimum of Eq. (34), and ρref,crit=ρthr/μmin⁡2\rho_{\mathrm{ref,crit}} = \rho_{\mathrm{thr}}/\mu^2_{\min}. Edge-on rows refer to (ι,ψ)=(90∘,0∘)(\iota,\psi) = (90^\circ,0^\circ). The completeness C=Ndet/N\mathcal{C} = N_{\mathrm{det}}/N counts the cells of the 10×1010 \times10 grid in (cos⁡ι,ψ)(\cos\iota,\psi) with R≥1\mathcal{R} \ge1, and ιmax⁡∃ψ\iota_{\max}^{\exists\psi} solves Eq. (35).

Inj. 1Inj. 2Inj. 3Inj. 4
How is the source oriented?
Frequency bin ff [Hz]26.34763.8452.81108.84
Sky position (RA, Dec)(14.8h,+42.9∘)(14.8^{\mathrm{h}}, +42.9^\circ)(13.3h,+75.7∘)(13.3^{\mathrm{h}}, +75.7^\circ)(20.2h,−83.8∘)(20.2^{\mathrm{h}}, -83.8^\circ)(11.9h,−33.4∘)(11.9^{\mathrm{h}}, -33.4^\circ)
Inclination ιinj\iota_{\mathrm{inj}} [deg]171.0128.362.494.6
Polarization angle ψinj\psi_{\mathrm{inj}} [deg]−35.2-35.2+0.5+0.5+20.9+20.9−25.5-25.5
cos⁡ιinj\cos\iota_{\mathrm{inj}}−0.988-0.988−0.619-0.619+0.463+0.463−0.081-0.081
Polarization statecircularellipticalellipticallinear
∣A×/A+∣\lvert A_\times/A_+\rvert1.000.900.760.16
Injected strain h0injh_0^{\mathrm{inj}}4.00×10−244.00 \times10^{-24}3.01×10−243.01 \times10^{-24}1.46×10−241.46 \times10^{-24}8.23×10−258.23 \times10^{-25}
What does the ASAF measure without correction?
heffh_{\mathrm{eff}}(3.91±0.07)×10−24(3.91 \pm0.07) \times10^{-24}(8.83±0.23)×10−25(8.83 \pm0.23) \times10^{-25}(7.99±0.24)×10−25(7.99 \pm0.24) \times10^{-25}(2.57±0.25)×10−25(2.57 \pm0.25) \times10^{-25}
Measured SNR ρ^\hat{\rho}26.6319.4616.575.20
Exceeds ρthr=6.19\rho_{\mathrm{thr}} = 6.19?yesyesyesno
What does the corrected analysis reveal?
μ2(ιinj,ψinj)\mu^2(\iota_{\mathrm{inj}},\psi_{\mathrm{inj}})0.9760.4310.2920.167
Correction factor 1/μ21/\sqrt{\mu^2}1.011.521.852.45
Face-on SNR ρref=ρ^/μ2\rho_{\mathrm{ref}} = \hat{\rho}/\sqrt{\mu^2}27.3±1.027.3 \pm1.045.2±2.345.2 \pm2.356.8±3.456.8 \pm3.431.1±6.031.1 \pm6.0
Recovered h0=heff/μ2h_0 = h_{\mathrm{eff}}/\sqrt{\mu^2}(3.96±0.07)×10−24(3.96 \pm0.07) \times10^{-24}(1.34±0.03)×10−24(1.34 \pm0.03) \times10^{-24}(1.48±0.04)×10−24(1.48 \pm0.04) \times10^{-24}(6.28±0.60)×10−25(6.28 \pm0.60) \times10^{-25}

Table II. How source orientation affects what the ASAF formalism measures. The top block gives the known source parameters, with ψ\psi in the convention of Eqs. (14) and (15). The middle block shows the uncorrected ASAF output, with σ(heff)=heff/(2ρ^)\sigma(h_{\mathrm{eff}}) = h_{\mathrm{eff}}/(2\hat{\rho}). The bottom block applies the orientation correction, with μ2=heff2/h02\mu^2 = h_{\mathrm{eff}}^2/h_0^2. Injection 4 falls below threshold. The recovered h0h_0 of Injections 2 and 4 is low because of the Doppler and pixel-phase losses of § 2 A.

Detection probability and orientation completeness

For each injection we evaluate ρrec\rho_{\mathrm{rec}} and PdetP_{\mathrm{det}} of Eqs. (37) and (39) at four reference orientations: face-on (μ2=1\mu^2 = 1), the true injection orientation (target), edge-on (ι=π/2\iota= \pi/2, ψ=0\psi= 0), and the isotropic average (μ2=2/5\mu^2 = 2/5). Face-on and at the isotropic average, all four injections have Pdet=1.000P_{\mathrm{det}} = 1.000. Even with 40% of the face-on power, every source stays well above threshold. Table III lists the target and edge-on values. Edge-on, only Injection 3 stays above threshold, with ρrec=7.10\rho_{\mathrm{rec}} = 7.10 and Pdet=0.820P_{\mathrm{det}} = 0.820. Even Injection 1 (ρref=27.3\rho_{\mathrm{ref}} = 27.3) drops to Pdet=0.001P_{\mathrm{det}} = 0.001. At its true orientation, Injection 4 has Pdet=0.161P_{\mathrm{det}} = 0.161.

We evaluate R\mathcal{R} on the 10×1010 \times10 grid in (cos⁡ι,ψ)(\cos\iota,\psi) of Eq. (41). Figure 2 shows the grid for all four injections and Table III summarizes it. Only Injection 3 is detected at every orientation, since its ρref=56.8\rho_{\mathrm{ref}} = 56.8 exceeds ρref,crit=49.5\rho_{\mathrm{ref,crit}} = 49.5. The other three are missed at the least

Figure 2. Detectability grid on the (ψ,cos⁡ι)(\psi,\cos\iota) plane for the four injections, evaluated at ρthr=6.19\rho_{\mathrm{thr}}=6.19. Filled circles mark orientations where R≥1\mathcal{R}\geq1 (detected). Open crosses mark R<1\mathcal{R}<1 (missed). The black cross marks the true injection orientation. Panel titles quote Ndet/NN_{\mathrm{det}}/N and ρref±σ(ρref)\rho_{\mathrm{ref}}\pm\sigma(\rho_{\mathrm{ref}}).

favorable orientations. Injection 4 is missed even at its true orientation (R=0.84\mathcal{R}=0.84), partly because of the bin-edge loss of § 2 A. Without that loss, its measured SNR would be about 9, above threshold.

Injection 4 also shows how much the interpretation depends on the orientation. Read at face value, ρ^=5.20\hat{\rho}=5.20 describes a source that is almost never detected (⟨Pdet⟩=0.01\langle P_{\mathrm{det}}\rangle=0.01). Divided by μ2\mu^2, it describes a source six times stronger, with ρref=31.1\rho_{\mathrm{ref}}=31.1, detected at 70% of orientations (⟨Pdet⟩=0.71\langle P_{\mathrm{det}}\rangle=0.71). This correction needs the orientation, which is known here only because the signals are injections. For a search candidate the orientation is unknown, so μ2\mu^2 cannot be divided out. Its intrinsic strength can then only be bounded, by an UL on h0h_0 marginalized over orientation (§ 2 D).

Upper limits

Table Table IV gives the 95% credible ULs on h0h_0 under the three prescriptions of Sec. IV B, with σλ=0.0465\sigma_\lambda=0.0465. The marginalized ULs are 2.69 to 2.85 times the circular ones, well above 5/2≈1.58\sqrt{5/2}\approx1.58 (Sec. IV C).

Inj. 1Inj. 2Inj. 3Inj. 4
[10−24^{-24}][10−25^{-25}][10−25^{-25}][10−25^{-25}]
h0ULh_0^{\mathrm{UL}} at 95% credible level
Circular (μ2=1\mu^2=1)4.119.348.492.94
At target4.1614.215.77.20
Marginalized11.725.222.88.16
Grid minimum4.339.838.933.10
Grid maximum12.826.323.89.76
Ratio to the circular upper limit
Marginalized / Circular2.852.702.692.77
Target / Circular1.011.521.852.45

Table 4. 95% credible ULs on h0h_0 for the four O2 hardware injections in units of 10−2410^{-24} (Injection 1) and 10−2510^{-25} (Injections 2 to 4), under the three prescriptions of Sec. IV B.

Figure Figure 3 shows the two posteriors for Injection 1, which has the highest SNR. The marginalized posterior extends to heff/μmin⁡2≃3heffh_{\mathrm{eff}}/\sqrt{\mu_{\min}^2}\simeq3h_{\mathrm{eff}}, and its ratio of 2.85. As a clear detection, Injection 1 is better described by an interval. At the injected orientation, the 90% credible interval [3.77, 4.16] ×10−24\times10^{-24} contains the injected 4.00 ×10−24\times10^{-24}. We quote 95% quantiles because the search reports them at every frequency-pixel pair. The marginalized posterior agrees in shape with Ref. [78].

Figure 3. Posterior on h0h_0 for Injection 1, circular (solid) and marginalized over orientation (dashed), each normalized to unit maximum. Vertical lines mark the 95% quantiles, which differ by a factor of 2.85.

The target-to-circular ratio is 1/μtarget21/\sqrt{\mu_{\mathrm{target}}^2}, from 1.01 for the nearly face-on Injection 1 to 2.45 for the nearly edge-on Injection 4. The at-target limit of Injection 4 lies below the injected h0h_0 because it covers only the power in the analyzed bin, about 60% of the signal (§ 2 A). Injection 2 lies above 160 Hz, where ASAF quotes no ULs [54]. We keep it because its losses cancel in the ratios. Matched-filter CW searches reach deeper ULs by tracking the Doppler modulation, at much higher computational cost [18, 60].

Application to O4a follow-up candidates

We now apply the formalism to the sub-threshold candidates of the O4a ASAF search [54], whose orientation is unknown. We ask two questions: what range of h0h_0 is compatible with the measured cross-power (Sec. VI B), and, if a candidate is a real source, how inclined it could be and still be detected (Sec. VI C). Section VI D tests both on a PHWI recovered in O4a, whose orientation is known. Neither question affects the significance of the candidates, whose threshold and pp-values remain as published.

O4a data set

The O4a ASAF analysis [54] used H1-L1 data, whose quality and sensitivity in O4a are described in Refs. [6, 89]. It selected 505 sub-threshold candidates for follow-up, between 23.8 and 1724.5 Hz, with 3.59≤ρ^≤5.473.59\leq\hat{\rho}\leq5.47. For each candidate, the released catalog gives the sky position, heffh_{\mathrm{eff}} with its uncertainty, and the published circular 95% UL. The PHWI at 52.8125 Hz is not in this list, and we treat it separately in Sec. VI D.

UL ranges for the candidates

For each candidate we first reproduce the published circular UL, with the prescription of Sec. IV A and σλ=0.0806\sigma_\lambda= 0.0806. We then compute two more limits. The first is the marginalized UL of Eq. (51), which assumes an unknown, isotropically distributed orientation. The second is the worst-orientation UL, which assumes the least favorable orientation. This is the edge-on case at ψ∗\psi^*, and by Eq. (49) it equals the circular UL times 8/(1−ϵ)\sqrt{8/(1-\epsilon)}.

Table V lists five representative candidates. Over all 505 candidates, the marginalized UL is 2.54 to 2.87 times the circular one, with a median of 2.68. This is the range expected from Sec. IV C. The worst-orientation UL is 2.83 times the circular one near the celestial poles. It rises to 3.63 times where ϵ=0.39\epsilon= 0.39. The published circular UL is therefore the lowest value of a range. The highest value is about three times larger. We propose that ASAF analyses in future observing runs report this range and the marginalized UL for each candidate, instead of the circular UL alone.

TABLE V: 95% credible ULs on h0h_0 for five O4a candidates. The columns give the circular UL, the UL marginalized over an isotropic orientation, and the UL at the least favorable orientation. Ratios to the circular UL are in parentheses.

ff [Hz]ρ^\hat{\rho}ϵ\epsilonCircular [10−2510^{-25}]Marginalized [10−2510^{-25}]Worst [10−2510^{-25}]
23.781253.590.18110.426.8 (2.58)32.4 (3.13)
38.687503.800.0013.548.99 (2.54)10.0 (2.83)
92.812505.220.1221.684.39 (2.61)5.08 (3.02)
228.968754.430.3941.323.76 (2.84)4.81 (3.63)
615.718755.470.0051.574.06 (2.58)4.46 (2.84)

Table V.

Maximum detectable inclination

If a candidate is a real source, a source of the same strength but more inclined produces less power. Beyond some inclination ιmax⁡\iota_{\max}, its SNR falls below ρthr\rho_{\rm thr}. Computing ιmax⁡\iota_{\max} requires ρref\rho_{\rm ref}, but only ρ^=μ2ρref\hat{\rho} = \mu^2\rho_{\rm ref} is measured, and μ2\mu^2 is unknown. We therefore assume that the candidate is a source at a typical orientation, μ2=⟨μ2⟩\mu^2 = \langle\mu^2\rangle, so that

ρref=ρ^⟨μ2⟩=2.5 ρ^.(53)\rho_{\rm ref} = \frac{\hat{\rho}}{\langle\mu^2\rangle} = 2.5\,\hat{\rho}. \tag*{(53)}

This value describes a hypothetical source. It is not a detection claim, and it is not compared with ρthr\rho_{\rm thr}, which applies to the measured ρ^\hat{\rho}. We now tilt this source away from face-on. By Eq. (37), its recovered SNR is μ2ρref\mu^2\rho_{\rm ref}. With the ψ\psi-averaged μ2\mu^2 of Eq. (27), the SNR falls to the threshold at the inclination ιmax⁡\iota_{\max} given by

1+6cos⁡2ιmax⁡+cos⁡4ιmax⁡8=ρthrρref,(54)\frac{1 + 6\cos^2\iota_{\max} + \cos^4\iota_{\max}}{8} = \frac{\rho_{\rm thr}}{\rho_{\rm ref}}, \tag*{(54)}

which gives

cos⁡2ιmax⁡=−3+8+8ρthr/ρref.(55)\cos^2\iota_{\max} = -3 + \sqrt{8 + 8\rho_{\rm thr}/\rho_{\rm ref}}. \tag*{(55)}

The exact ιmax⁡\iota_{\max} also depends on ψ\psi. Two limiting cases bound it. Setting ϵ=1\epsilon= 1 in Eq. (33) gives μ2=A+2\mu^2 = \mathcal{A}_+^2 at the best ψ\psi and μ2=A×2\mu^2 = \mathcal{A}_\times^2 at the worst. Real sky positions have ϵ≤0.395\epsilon\le0.395, so the true ιmax⁡\iota_{\max} lies between these two envelopes.

Table VI and Figure 4 show the results. The ψ\psi-averaged ιmax⁡\iota_{\max} ranges from 34.7∘34.7^\circ to 50.3∘50.3^\circ, with a median of 43.9∘43.9^\circ. No candidate reaches 60∘60^\circ, even at the best ψ\psi. For isotropic orientations cos⁡ι\cos\iota is uniform, so the fraction of sources with ι<ιmax⁡\iota< \iota_{\max} is the orientation coverage Corient=1−cos⁡ιmax⁡\mathcal{C}_{\rm orient} = 1 - \cos\iota_{\max}. It is only 18% to 36%. A source as strong as these candidates is therefore detected only if it lies within about 35∘35^\circ to 50∘50^\circ of face-on.

TABLE VI: Maximum detectable inclination ιmax⁡\iota_{\max} for the 504 O4a follow-up candidates, for a source with ρref=2.5 ρ^\rho_{\rm ref} = 2.5\,\hat{\rho}. Best ψ\psi and worst ψ\psi are the two envelopes. The last row counts the candidates with ιmax⁡≥45∘\iota_{\max} \ge45^\circ.

Statisticιmax⁡\iota_{\max} (ψ\psi-avg)ιmax⁡\iota_{\max} (best ψ\psi)ιmax⁡\iota_{\max} (worst ψ\psi)
Minimum34.7∘34.7^\circ35.6∘35.6^\circ33.9∘33.9^\circ
Median43.9∘43.9^\circ46.1∘46.1^\circ42.2∘42.2^\circ
Mean44.0∘44.0^\circ46.3∘46.3^\circ42.3∘42.3^\circ
Maximum50.3∘50.3^\circ54.0∘54.0^\circ47.7∘47.7^\circ
N(ιmax⁡≥45∘)N(\iota_{\max} \ge45^\circ)128/504397/50430/504

Table VI.

Figure 4. Maximum detectable inclination ιmax⁡\iota_{\max} (upper panel) and orientation coverage Corient=1−cos⁡ιmax⁡C_{\mathrm{orient}} = 1 - \cos\iota_{\max} (lower panel) as a function of ρ^\hat{\rho} over the range of the O4a candidates. The shaded band lies between the best-ψ\psi and worst-ψ\psi envelopes (dashed curves). Dotted curves show the effect of ±1σ\pm1\sigma noise on ρ^\hat{\rho}.

The PHWI at 52.8125 Hz

Of the O4a PHWIs [97], only the one at 52.8125 Hz was recovered as a follow-up candidate. Its parameters are Dec =−83.8∘= -83.8^\circ, ι=62.4∘\iota= 62.4^\circ, ψ=+20.9∘\psi= +20.9^\circ, and h0=3.99×10−25h_0 = 3.99 \times10^{-25}. The O4a ASAF analysis recovered it at ρ^=4.25\hat{\rho} = 4.25, below the detection threshold [54]. Since the injection lies close to the celestial pole, ϵ≈10−3\epsilon\approx10^{-3} and μ2\mu^2 depends on the orientation alone, giving μ2=0.292\mu^2 = 0.292.

Viewed face-on, the same source would have ρref=14.6±3.4\rho_{\rm ref} = 14.6 \pm3.4, well above threshold. For this strength ιmax⁡=52.2∘\iota_{\max} = 52.2^\circ, and the injected inclination of 62.4∘62.4^\circ lies beyond it. This is why the injection was missed. The recovered amplitude agrees with this formalism. A face-on reading would give heff=h0h_{\rm eff} = h_0, whereas Eq. (36) predicts μ2 h0=2.15×10−25\sqrt{\mu^2}\,h_0 = 2.15 \times10^{-25}. At the known orientation, the UL is 1.85 times the circular one. The marginalized and worst-orientation limits are 2.56 and 2.83 times the circular one.

Conclusions

The ASAF radiometer gives equal weight to the ++ and ×\times polarization states. This is optimal for an unpolarized SGWB, but it underestimates the strength of CW sources. The projection factor μ2(ι,ψ)=heff2/h02\mu^2(\iota,\psi) = h_{\mathrm{eff}}^2/h_0^2 [77, 78] measures this effect. It is the ratio of the cross-power the radiometer measures to that of a face-on source with the same h0h_0. We showed that its isotropic average is exactly 2/52/5, independent of sky position, detector geometry, noise weighting, and frequency, and that its dependence on ψ\psi has the closed form of Eq. (33).

The four O2 hardware injections confirm the formalism. The measured SNR is only a fraction μ2\mu^2 of the face-on value. For Injection 4, ρ^=5.20\hat{\rho}=5.20 falls below threshold, although ρref=31.1±6.0\rho_{\mathrm{ref}}=31.1\pm6.0. Dividing heffh_{\mathrm{eff}} by μ2\sqrt{\mu^2} recovers the injected h0h_0, once the known Doppler and pixel-phase losses are included. ULs marginalized over orientation, as in Refs. [76, 78], are 2.7 to 2.9 times the circular ones for the injections. They follow from the published ASAF prescription with the single substitution heff2→μ2h02h_{\mathrm{eff}}^2 \rightarrow\mu^2 h_0^2.

For the 505 O4a follow-up candidates, the correction leaves every pp-value unchanged but changes their interpretation. Each published circular UL is the lowest value of a range over orientation whose highest value is about three times larger, and the marginalized UL is 2.5 to 2.9 times the circular one. A source as strong as these candidates is detected only within 35∘35^\circ to 50∘50^\circ of face-on, which covers only 18% to 36% of isotropic orientations. The PHWI at 52.8125 Hz illustrates this. It was recovered at ρ^=4.25\hat{\rho}=4.25, although viewed face-on it would have had ρref=14.6±3.4\rho_{\mathrm{ref}}=14.6\pm3.4, a confident detection. Its inclination of 62.4∘62.4^\circ lies beyond the detectable 52.2∘52.2^\circ, and its recovered amplitude follows the orientation prediction, not the face-on one.

These results have three practical implications. First, face-on ULs are 2 to 3 times lower than those for a randomly oriented source. We recommend quoting them as a range over orientation. Second, ιmax⁡\iota_{\max} and CorientC_{\mathrm{orient}} should be reported alongside ρ^\hat{\rho} and heffh_{\mathrm{eff}}. Third, a low ρ^\hat{\rho} does not imply a weak source. The significance of a candidate is unchanged, but the intrinsic strength behind a given ρ^\hat{\rho} can be up to 1/μmin⁡2≈81/\mu_{\min}^2 \approx8 to 13 times larger. Selecting candidates by ρ^\hat{\rho} alone therefore favors face-on sources, and follow-up searches should take this into account.

Acknowledgments

This research has made use of data or software obtained from the Gravitational Wave Open Science Center (gwosc.org) [98, 99], a service of the LIGO Scientific Collaboration, the Virgo Collaboration, and KAGRA. This material is based upon work supported by NSF’s LIGO Laboratory which is a major facility fully funded by the National Science Foundation. The LIGO document number of this article is LIGO-P2600518. The authors are grateful to Deepali Agarwal for valuable discussions on this topic and for sharing her expertise on the ASAF search, and to Federico De Lillo for his careful reading of the manuscript and constructive feedback. Stavros Venikoudis is supported by a grant from the Fonds pour la formation à la Recherche dans l’Industrie et dans l’Agriculture (FRIA), awarded by the Fonds de la Recherche Scientifique (F.R.S.-FNRS), Belgium. The data analysis in this work was performed using NumPy [100], SciPy [101], and HEALPy [102]. All figures were produced with Matplotlib [103]. The sky pixelization uses the HEALPix framework [79].

Derivation of the CW cross-correlated power

The phase of a signal with frequency drift f˙\dot{f} is Φ(t)=2π(f0t+f˙t2/2)\Phi(t)=2\pi(f_0t+\dot{f}t^2/2). Over an SFT of duration TT, the drift adds a phase πf˙T2\pi\dot{f}T^2 to that of a monochromatic signal. The largest drift comes from the rotation of the Earth. Its centripetal acceleration, a≃0.03 m s−2a \simeq0.03\ \mathrm{m\,s^{-2}}, gives

񎟙 f˙/f0≤a/c≃10−10 s−1\dot{f}/f_0 \le a/c \simeq10^{-10}\ \mathrm{s}^{-1}. Keeping the added phase below π/2\pi/2 requires T≲3×103500 Hz/f0T \lesssim3 \times10^3\sqrt{500\ \mathrm{Hz}/f_0}. Spin-down gives a weaker bound. The SFTs of T=192 sT = 192\ \mathrm{s} used here (Sec. II B) satisfy both.

Within an SFT, the signal is therefore monochromatic at the instantaneous frequency f0(t)f_0(t). The SFT of Eq. (18) then consists of two lines at ±f0(t)\pm f_0(t),

h~Ii(t;f)=A+FIi+−iA×FIi×2ei[ΦIi(t)−2πft]δT(f−f0(t))+A+FIi++iA×FIi×2e−i[ΦIi(t)+2πft]δT(f+f0(t)),(56)\widetilde{h}_{I_i}(t;f) = \frac{A_+F^+_{I_i}-iA_\times F^\times_{I_i}}{2}e^{i[\Phi_{I_i}(t)-2\pi f t]}\delta_T(f-f_0(t))+\frac{A_+F^+_{I_i}+iA_\times F^\times_{I_i}}{2}e^{-i[\Phi_{I_i}(t)+2\pi f t]}\delta_T(f+f_0(t)), \tag*{(56)}

where

δT(f)=∫−T/2T/2e−2πift′ dt′=sin⁡(πfT)πf(57)\delta_T(f)=\int_{-T/2}^{T/2}e^{-2\pi i f t'}\,\mathrm{d}t'=\frac{\sin(\pi fT)}{\pi f} \tag*{(57)}

is the finite-time Dirac delta function [21] with width ∼1/T\sim1/T and height δT(0)=T\delta_T(0)=T. Multiplying the positive-frequency lines of the two detectors gives Eq. (19). The negative-frequency lines give its complex conjugate at −f0(t)-f_0(t). The initial phase, the intrinsic phase evolution, and the reference phase e−2πifte^{-2\pi i f t} are common to both detectors and cancel. Only the differential phase remains,

ΔΦI(t)=ΦI2(t)−ΦI1(t)=2πfn^⋅Δx⃗ I(t)c.(58)\Delta\Phi_I(t)=\Phi_{I_2}(t)-\Phi_{I_1}(t)=2\pi f\frac{\hat{\boldsymbol{n}}\cdot\Delta\vec{x}^{\,I}(t)}{c}. \tag*{(58)}

Spin-down enters Eq. (58) only through the drift of f0(t)f_0(t) times the light travel time across the baseline. Over an O2-length run, this is below 2×10−3 rad2\times10^{-3}\ \mathrm{rad} even at the spin-down limit of Sec. II E, and we neglect it.

Closed form and modulation depth

Equations (14) and (15) combine into Fi++iFi×=zie2iψF_i^+ + iF_i^\times=z_i e^{2i\psi}, with zi=ai+ibiz_i=a_i+ib_i, so the polarization angle enters only as a phase. The two polarization products are then

F1+F2++F1×F2×=Re⁡(z1z‾2)=At,(59)F_1^+F_2^+ + F_1^\times F_2^\times=\operatorname{Re}(z_1\overline{z}_2)=A_t, \tag*{(59)}
F1+F2+−F1×F2×=Re⁡(z1z2e4iψ),(60)F_1^+F_2^+ - F_1^\times F_2^\times=\operatorname{Re}(z_1z_2e^{4i\psi}), \tag*{(60)}

which are Eqs. (29) and (30), with Ct(1)+iCt(2)=z1z2C_t^{(1)}+iC_t^{(2)}=z_1z_2. We write Re⁡Gt=A+2F1+F2++A×2F1×F2×\operatorname{Re}G_t=A_+^2F_1^+F_2^+ + A_\times^2F_1^\times F_2^\times as (A+2+A×2)/2(A_+^2+A_\times^2)/2 times the sum of the two products plus (A+2−A×2)/2(A_+^2-A_\times^2)/2 times their difference. Inserting this in Eq. (25) with γt=At\gamma_t=A_t gives

μ2=A+2+A×22+A+2−A×22Re⁡(e4iψC(1)+iC(2)D),(61)\mu^2=\frac{A_+^2+A_\times^2}{2}+\frac{A_+^2-A_\times^2}{2}\operatorname{Re}\left(e^{4i\psi}\frac{C^{(1)}+iC^{(2)}}{D}\right), \tag*{(61)}

which is Eq. (33), since C(1)+iC(2)=εDeiδC^{(1)}+iC^{(2)}=\varepsilon D e^{i\delta} by Eq. (32). With uniform weights the time sums involve only aia_i and bib_i, so ε\varepsilon and δ\delta do not depend on frequency. The bound ε≤1\varepsilon\le1 ensures μ2≥A×2≥0\mu^2\ge A_\times^2\ge0, which keeps μ2\sqrt{\mu^2} in Eq. (36) real.

With uniform weights, ε\varepsilon depends on declination alone. Each term of the time sums depends on sidereal time and right ascension only through their difference. A change of right ascension therefore shifts the sum over a full day and leaves it unchanged. At the celestial poles the rotation of the Earth turns both detectors about the line of sight. The phase of z1z2z_1z_2 then advances uniformly over the day, and ε=0\varepsilon=0. The modulation is largest on the two rings at Dec≃±19.5∘\mathrm{Dec}\simeq\pm19.5^\circ.

References

References

  1. [1]B. P. Abbott et al. (KAGRA, LIGO Scientific, Virgo), Living Rev. Rel. 21, 3 (2018), arXiv:1304.0670 [gr-qc].
  2. [2]A. Buikema et al. (aLIGO), Phys. Rev. D 102, 062003 (2020), arXiv:2008.01301 [astro-ph.IM].DOI
  3. [3]J. Aasi et al. (LIGO Scientific), Class. Quant. Grav. 32, 074001 (2015), arXiv:1411.4547 [gr-qc].
  4. [4]F. Acernese et al. (Virgo), Phys. Rev. Lett. 123, 231108 (2019).
  5. [5]T. Akutsu et al. (KAGRA), PTEP 2021, 05A101 (2021), arXiv:2005.05574 [physics.ins-det].arxiv.org/abs/2005.05574
  6. [6]E. Capote et al., Phys. Rev. D 111, 062002 (2025), arXiv:2411.14607 [gr-qc].DOI
  7. [7]F. Acernese et al. (Virgo), (2026), arXiv:2607.26872 [gr-qc].arxiv.org/abs/2607.26872
  8. [8]B. P. Abbott et al. (LIGO Scientific, Virgo), Phys. Rev. Lett. 116, 061102 (2016), arXiv:1602.03837 [gr-qc].
  9. [9]B. P. Abbott et al. (LIGO Scientific, Virgo), Phys. Rev. Lett. 119, 161101 (2017), arXiv:1710.05832 [gr-qc].
  10. [10]R. Abbott et al. (LIGO Scientific, KAGRA, Virgo),
  11. [11]B. P. Abbott et al. (LIGO Scientific, Virgo), Phys. Rev. X 9, 031040 (2019), arXiv:1811.12907 [astro-ph.HE].DOI
  12. [12]R. Abbott et al. (LIGO Scientific, Virgo), Phys. Rev. X 11, 021053 (2021), arXiv:2010.14527 [gr-qc].DOI
  13. [13]R. Abbott et al. (KAGRA, Virgo, LIGO Scientific), Phys. Rev. X 13, 041039 (2023), arXiv:2111.03606 [gr-qc].DOI
  14. [14]A. G. Abac et al. (LIGO Scientific, Virgo, KAGRA), (2025), arXiv:2508.18082 [gr-qc].DOI
  15. [15]A. G. Abac et al. (LIGO Scientific, Virgo, KAGRA), (2025), arXiv:2508.18083 [astro-ph.HE].DOI
  16. [16]K. Riles, Mod. Phys. Lett. A 32, 1730035 (2017), arXiv:1712.05897 [gr-qc].DOI
  17. [17]M. Sieniawska and M. Bejger, Universe 5, 217 (2019), arXiv:1909.12600 [astro-ph.HE].DOI
  18. [18]K. Wette, Astropart. Phys. 153, 102880 (2023), arXiv:2305.07106 [astro-ph.HE]. [19] P. D. Lasky, Publ. Astron. Soc. Austral. 32, e034 (2015), arXiv:1508.06643 [astro-ph.HE].DOI
  19. [20]R. Abbott et al. (LIGO Scientific, KAGRA, Virgo), Phys. Rev. D 104, 122004 (2021), arXiv:2107.03701 [gr-qc].DOI
  20. [21]B. Allen and J. D. Romano, Phys. Rev. D 59, 102001 (1999), arXiv:gr-qc/9710117.DOI
  21. [22]J. D. Romano and N. J. Cornish, Living Rev. Rel. 20, 2 (2017), arXiv:1608.06889 [gr-qc].DOI
  22. [23]N. Christensen, Rept. Prog. Phys. 82, 016903 (2019), arXiv:1811.08797 [gr-qc].DOI
  23. [24]A. I. Renzini, B. Goncharov, A. C. Jenkins, and P. M. Meyers, Galaxies 10, 34 (2022), arXiv:2202.00178 [gr-qc].arxiv.org/abs/2202.00178
  24. [25]N. van Remortel, K. Janssens, and K. Turbang, Prog. Part. Nucl. Phys. 128, 104003 (2023), arXiv:2210.00761 [gr-qc].DOI
  25. [26]A. G. Abac et al. (Virgo, KAGRA, LIGO Scientific), Phys. Rev. D 114, 042001 (2026), arXiv:2508.20721 [gr-qc].arxiv.org/abs/2508.20721
  26. [27]A. G. Abac et al. (LIGO Scientific, Virgo, KAGRA), (2025), arXiv:2510.26848 [gr-qc].arxiv.org/abs/2510.26848
  27. [28]A. G. Abac et al. (LIGO Scientific, Virgo, KAGRA), (2026), arXiv:2608.23477 [gr-qc].arxiv.org/abs/2608.23477
  28. [29]L. P. Grishchuk, Sov. Phys. JETP 40, 409 (1975).
  29. [30]A. A. Starobinsky, JETP Lett. 30, 682 (1979).
  30. [31]C. Caprini et al., JCAP 2020 (03), 024, arXiv:1910.13125 [astro-ph.CO].DOI
  31. [32]M. Hindmarsh, S. J. Huber, K. Rummukainen, and D. J. Weir, Phys. Rev. D 96, 103520 (2017), arXiv:1704.05871 [astro-ph.CO].arxiv.org/abs/1704.05871
  32. [33]T. W. B. Kibble, J. Phys. A 9, 1387 (1976).
  33. [34]S. Sarangi and S. H. H. Tye, Phys. Lett. B 536, 185 (2002), arXiv:hep-th/0204074.DOI
  34. [35]P. Auclair et al., JCAP 2020 (04), 034, arXiv:1909.00819 [astro-ph.CO].DOI
  35. [36]X. Martin and A. Vilenkin, Phys. Rev. Lett. 77, 2879 (1996), arXiv:astro-ph/9606022.DOI
  36. [37]A. C. Jenkins, M. Sakellariadou, T. Regimbau, and E. Slezak, Phys. Rev. D 98, 063501 (2018), arXiv:1806.01718 [astro-ph.CO].DOI
  37. [38]G. Cusin, I. Dvorkin, C. Pitrou, and J.-P. Uzan, Phys. Rev. Lett. 120, 231101 (2018), arXiv:1803.03236 [astro-ph.CO].
  38. [39]G. Mentasti, M. Peloso, and L. Valbusa Dall’Armi, Phys. Rev. D 108, 023523 (2023), arXiv:2301.08074 [astro-ph.CO].arxiv.org/abs/2301.08074
  39. [40]P. A. Rosado, Phys. Rev. D 86, 104007 (2012), arXiv:1206.1330 [gr-qc].DOI
  40. [41]X.-J. Zhu, E. Howell, T. Regimbau, D. Blair, and Z.-H. Zhu, Astrophys. J. 739, 86 (2011), arXiv:1104.3565 [gr-qc].DOI
  41. [42]D. Talukder, E. Thrane, S. Bose, and T. Regimbau, Phys. Rev. D 89, 123008 (2014), arXiv:1404.4025 [gr-qc].DOI
  42. [43]A. Buonanno, G. Sigl, G. G. Raffelt, H.-T. Janka, and E. Muller, Phys. Rev. D 72, 084001 (2005), arXiv:astro-ph/0412277.DOI
  43. [44]K. Crocker, V. Mandic, T. Regimbau, K. Belczynski, W. Gladysz, K. Olive, T. Prestegard, and E. Vangioni, Phys. Rev. D 92, 063005 (2015), arXiv:1506.02631 [gr-qc].DOI
  44. [45]N. Christensen, Phys. Rev. D 46, 5250 (1992).
  45. [46]E. E. Flanagan, Phys. Rev. D 48, 2389 (1993), arXiv:astro-ph/9305029.DOI
  46. [47]S. W. Ballmer, Class. Quant. Grav. 23, S179 (2006), arXiv:gr-qc/0510096.DOI
  47. [48]S. Mitra, S. Dhurandhar, T. Souradeep, A. Lazzarini, V. Mandic, S. Bose, and S. Ballmer, Phys. Rev. D 77, 042002 (2008), arXiv:0708.2728 [gr-qc].DOI
  48. [49]E. Thrane, S. Ballmer, J. D. Romano, S. Mitra, D. Talukder, S. Bose, and V. Mandic, Phys. Rev. D 80, 122002 (2009), arXiv:0910.0858 [astro-ph.IM].DOI
  49. [50]P. B. Abbott et al. (LIGO Scientific, Virgo), Phys. Rev. Lett. 118, 121102 (2017), arXiv:1612.02030 [gr-qc].DOI
  50. [51]B. P. Abbott et al. (LIGO Scientific, Virgo), Phys. Rev. D 100, 062001 (2019), arXiv:1903.08844 [gr-qc].DOI
  51. [52]R. Abbott et al. (KAGRA, Virgo, LIGO Scientific), Phys. Rev. D 104, 022005 (2021), arXiv:2103.08520 [gr-qc].DOI
  52. [53]R. Abbott et al. (KAGRA, Virgo, LIGO Scientific), Phys. Rev. D 105, 122001 (2022), arXiv:2110.09834 [gr-qc].DOI
  53. [54]A. G. Abac et al. (LIGO Scientific, Virgo, KAGRA), (2025), arXiv:2510.17487 [gr-qc].DOI
  54. [55]A. Ain, J. Suresh, and S. Mitra, Phys. Rev. D 98, 024001 (2018), arXiv:1803.08285 [gr-qc].DOI
  55. [56]A. I. Renzini and C. R. Contaldi, Mon. Not. Roy. Astron. Soc. 486, 5564 (2019), arXiv:1811.12922 [gr-qc].DOI
  56. [57]J. Suresh, A. Ain, and S. Mitra, Phys. Rev. D 103, 083024 (2021), arXiv:2011.05969 [gr-qc].DOI
  57. [58]D. Agarwal, J. Suresh, S. Mitra, and A. Ain, Phys. Rev. D 104, 123018 (2021), arXiv:2106.09540.
  58. [59]R. Tenorio, D. Keitel, and A. M. Sintes, Universe 7, 474 (2021), arXiv:2105.13270 [gr-qc].
  59. [60]K. Riles, Living Rev. Rel. 26, 3 (2023), arXiv:2206.06447 [astro-ph.HE].DOI
  60. [61]A. M. Knee, H. Du, E. Goetz, J. McIver, J. B. Carlin, L. Sun, L. Dunn, L. Strang, H. Middleton, and A. Melatos, Phys. Rev. D 109, 062008 (2024), arXiv:2311.12138 [gr-qc].DOI
  61. [62]C. Salvadore, I. La Rosa, P. Leaci, F. Amicucci, P. Astone, S. D’Antonio, L. D’Onofrio, C. Palomba, L. Pierini, and F. Safa Tehrani, Phys. Rev. D 112, 083051 (2025), arXiv:2507.15027 [astro-ph.HE].DOI
  62. [63]A. Arvanitaki, S. Dimopoulos, S. Dubovsky, N. Kaloper, and J. March-Russell, Phys. Rev. D 81, 125330 (2010), arXiv:0905.4720 [hep-th].DOI
  63. [64]A. Arvanitaki, M. Baryakhtar, and X. Huang, Phys. Rev. D 91, 084011 (2015), arXiv:1411.2263 [hep-ph].DOI
  64. [65]S. Venikoudis, F. De Lillo, K. Janssens, J. Suresh, and G. Bruno, Phys. Rev. D 111, 082005 (2025), arXiv:2411.11746 [gr-qc].arxiv.org/abs/2411.11746
  65. [66]A. Sharma, D. Agarwal, and S. Mitra, Phys. Rev. D 113, 063057 (2026), arXiv:2511.17758 [gr-qc].DOI
  66. [67]A. M. Knee, K. Riles, and L. Sun, (2026), arXiv:2608.07312 [gr-qc].arxiv.org/abs/2608.07312
  67. [68]A. Nishizawa, A. Taruya, K. Hayama, S. Kawamura, and M.-a. Sakagami, Phys. Rev. D 79, 082002 (2009), arXiv:0903.0528 [astro-ph.CO].DOI
  68. [69]P. Jaranowski, A. Krolak, and B. F. Schutz, Phys. Rev. D 58, 063001 (1998), arXiv:gr-qc/9804014.DOI
  69. [70]R. J. Dupuis and G. Woan, Phys. Rev. D 72, 102002 (2005), arXiv:gr-qc/0508096.DOI
  70. [71]C. Biver et al., Phys. Rev. D 95, 062002 (2017), arXiv:1612.07864 [astro-ph.IM].
  71. [72]C. Dreissigacker, R. Prix, and K. Wette, Phys. Rev. D 98, 084058 (2018), arXiv:1808.02459 [gr-qc].DOI
  72. [73]S. Dhurandhar, B. Krishnan, H. Mukhopadhyay, and J. T. Whelan, Phys. Rev. D 77, 082001 (2008), arXiv:0712.1578 [gr-qc].
  73. [74]J. T. Whelan, S. Sundaresan, Y. Zhang, and P. Peiris, Phys. Rev. D 91, 102005 (2015), arXiv:1504.05890 [gr-qc].
  74. [75]T. Boybeyi and V. Mandic, (2026), arXiv:2605.25772 [gr-qc].
  75. [76]C. Messenger, Understanding the sensitivity of the stochastic radiometer analysis in terms of the strain tensor amplitude, Tech. Rep. LIGO-T1000195 (LIGO Scientific Collaboration, 2010).
  76. [77]C. Messenger et al., Phys. Rev. D 92, 023006 (2015), arXiv:1504.05889 [gr-qc].
  77. [78]P. M. Meyers, Cross-correlation Searches for Persistent Gravitational Waves with Advanced LIGO and Noise Studies for Current and Future Ground-based Gravitational-wave Detectors, Ph.D. thesis, University of Minnesota (2018).
  78. [79]K. M. Górski, E. Hivon, A. J. Banday, B. D. Wandelt, F. K. Hansen, M. Reinecke, and M. Bartelmann, Astrophys. J. 622, 759 (2005), arXiv:astro-ph/0409513.
  79. [80]E. Thrane, S. Mitra, N. Christensen, V. Mandic, and A. Ain, Phys. Rev. D 91, 124012 (2015), arXiv:1504.02158 [astro-ph.IM].
  80. [81]A. Ain, P. Dalvi, and S. Mitra, Phys. Rev. D 92, 022003 (2015), arXiv:1504.01714 [gr-qc].
  81. [82]L. S. Finn, S. L. Larson, and J. D. Romano, Phys. Rev. D 79, 062003 (2009), arXiv:0811.3582 [gr-qc].
  82. [83]S. Panda, S. Bhagwat, J. Suresh, and S. Mitra, Phys. Rev. D 100, 043541 (2019).
  83. [84]A. I. Renzini and C. R. Contaldi, Phys. Rev. Lett. 122, 081102 (2019), arXiv:1806.11360 [astro-ph.IM].
  84. [85]A. I. Renzini and C. R. Contaldi, Phys. Rev. D 100, 063527 (2019), arXiv:1907.10329 [gr-qc].
  85. [86]L. Xiao, A. I. Renzini, and A. J. Weinstein, Phys. Rev. D 107, 122002 (2023).
  86. [87]P. B. Covas et al. (LIGO Scientific), Phys. Rev. D 97, 082002 (2018), arXiv:1801.07204 [astro-ph.IM].
  87. [88]D. Davis et al. (LIGO), Class. Quant. Grav. 38, 135014 (2021), arXiv:2101.11673 [astro-ph.IM].
  88. [89]S. Soni et al. (LIGO), Class. Quant. Grav. 42, 085016 (2025), arXiv:2409.02831 [astro-ph.IM].
  89. [90]E. Goetz et al. (O4 LIGO Detector), (2026), arXiv:2606.05959 [astro-ph.IM].
  90. [91]Z. Šidák, J. Amer. Statist. Assoc. 62, 626 (1967).
  91. [92]W. G. Anderson, P. R. Brady, J. D. E. Creighton, and E. E. Flanagan, Phys. Rev. D 63, 042003 (2001), arXiv:gr-qc/0008066.
  92. [93]A. Matas and J. D. Romano, Phys. Rev. D 103, 062003 (2021), arXiv:2012.00907 [gr-qc].
  93. [94]J. T. Whelan, E. L. Robinson, J. D. Romano, and E. H. Thrane, J. Phys. Conf. Ser. 484, 012027 (2014), arXiv:1205.3112 [gr-qc].
  94. [95]C. Cahillane et al., Phys. Rev. D 96, 102001 (2017), arXiv:1708.03023 [astro-ph.IM].
  95. [96]B. P. Abbott et al. (LIGO Scientific, Virgo), Astrophys. J. 713, 671 (2010), arXiv:0909.3583 [astro-ph.HE].
  96. [97]P. Baxi, J. Leviton, E. Morag, M. Pitkin, and K. Ribelin, Class. Quant. Grav. 43, 135019 (2026), arXiv:2601.09918 [astro-ph.IM].
  97. [98]R. Abbott et al. (LIGO Scientific, Virgo), SoftwareX 13, 100658 (2021), arXiv:1912.11716 [gr-qc].
  98. [99]A. G. Abac et al. (LIGO Scientific, Virgo, KAGRA), Astrophys. J. 1004, 232 (2026), arXiv:2508.18079 [gr-qc].
  99. [100]S. van der Walt, S. C. Colbert, and G. Varoquaux, Comput. Sci. Eng. 13, 22 (2011).
  100. [101]P. Virtanen, R. Gommers, T. E. Oliphant, M. Haberland, T. Reddy, D. Cournapeau, E. Burovski, P. Peterson, W. Weckesser, J. Bright, S. J. van der Walt, M. Brett, J. Wilson, K. J. Millman, N. Mayorov, A. R. J. Nelson, E. Jones, R. Kern, E. Larson, C. J. Carey, I. Polat, Y. Feng, E. W. Moore, J. VanderPlas, D. Laxalde, J. Perktold, R. Cimrman, I. Henriksen, E. A. Quintero, C. R. Harris, A. M. Archibald, A. H. Ribeiro, F. Pedregosa, P. van Mulbregt, and SciPy 1.0 Contributors, Nature Methods 17, 261 (2020).
  101. [102]A. Zonca, L. Singer, D. Lenz, M. Reinecke, C. Rosber, E. Hivon, and K. Gorski, J. Open Source Softw. 4, 1298 (2019).
  102. [103]J. D. Hunter, Comput. Sci. Eng. 9, 90 (2007).

Paper details

vlnc:W_3esn327u
Version
v1 · latest
Published
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents