Compact beam position monitor using a segmented toroidal coil
Abstract
A new, compact beam position monitor based on segmented a toroidal coil surrounding the charged particle beam has been investigated. It makes use of the induced voltages in the windings instead of the induced charge imbalance on capacitor plates in the conventional beam position monitors. We theoretically investigate the response of the coils to the bunched particle beam based on a lumped element model and compare it with measurements in the laboratory and in the storage ring COSY, in terms of beam displacement. As to the frequency response of the coils, we find a resonant behavior, which may be exploited to increase the sensitivity of the device further. The resolution presently achieved is about 5 micrometer in a one second time interval for a beam current of 0.5 mA.
Introduction
Experiments searching for Electric Dipole Moments (EDMs) of charged particles using storage rings are at the forefront of the incessant quest to find new physics beyond the Standard Model (SM). These investigations bear the potential to shed light on the origin of the hitherto unexplained large matter-antimatter asymmetry in the Universe [1, 2]. The combined predictions of the SM of particle physics and of cosmology fall short of the experimentally observed asymmetry by about seven to eight orders of magnitude [3].
The JEDI collaboration (Jülich Electric Dipole moment Investigations, see http://collaborations.fz-juelich.de/ikp/jedi) is currently leading the effort to scrutinize the technical feasibility of the storage ring approach to the determination of the EDMs of protons [4]. In the framework of systematic beam and spin dynamics studies, a dedicated experiment to determine the deuteron EDM [5, 6, 7] is presently being carried out at the storage ring COSY in Jülich (Cooler Synchrotron COSY at Forschungszentrum Jülich, Germany [8, 9]).
Given the extremely small anticipated values of the EDMs of the charged particles, down to e cm, the control of systematic effects in the ring is of paramount importance, and high-precision monitoring of the positions of the beams in the ring constitutes one of the great challenges in these experiments. This entails precise control of the beam positions along the orbit in the machine. In order to improve the knowledge about the absolute beam orbit in COSY, various alignment campaigns were conducted, during which all magnetic elements in the machine were positioned to about 0.2 mm, or 0.2 mrad, respectively. In addition, absolute beam-offset parameters for each of the installed BPMs were obtained from a dedicated beam-based alignment effort, as described in[10].
The beam position monitors (BPMs) used at COSY are capacitive measuring devices[8, 11]. The position of the beam is determined based on the induced charge imbalance on opposing capacitor plates. The typical insertion length of such a pair of BPMs along the beam direction, providing horizontal and vertical positions, amounts to about 500 mm. For beams comprising approximately particles, capacitive BPMs provide a resolution of a few µm for a measurement time of 1 s and an accuracy of about 100 µm.
These capacitive BPMs, however, appear unattractive because their length limits the number of devices that can actually be installed in a machine. It is therefore imperative to develop alternative BPMs that require significantly less installation space. In our case, it was not possible to install conventional BPMs in front of and behind a one-meter-long radio frequency Wien filter[12], essential for the EDM experiments. Therefore, a newly developed device was used to determine the beam position during the EDM measurements.
In this publication, we describe an approach based on the induction of voltages in opposing segments of a compact toroidal coil through which the beam passes, providing a position value based on the measured voltage imbalance. Previous studies of our group are discussed in proceedings[13] and in a PhD thesis[14]. Prior to our work, these so-called Rogowski coils for determining the beam current and the beam position were discussed in reference[15]. In this document, we will discuss the theoretical description and the resonant behavior in detail.
One advantage of induction coils for this particular application, apart from their mechanical simplicity, is that they offer a large sensor surface in small volume due to the large number of windings. In addition they can be operated in resonance to increase the induced voltage and that – due to the induction principle – they benefit from the high revolution frequency of the beam. Furthermore it should be noted that BPMs based on induction coils are sensitive to the time derivative of the beam current , while capacitive BPMs are sensitive to . Unlike BPM systems based on SQUIDs[16], they do not necessarily require low temperatures or vacuum conditions during testing and beam operation, which facilitates their development in the laboratory. Because of their short insertion length of about 5 cm, Rogowski-type BPMs appear ideally suited for a future dedicated EDM storage ring, see Chaps. 7 and 8 of Ref.[4].
This paper is organized as follows. In Sec. II, the basic principles of BPMs based on toroidal coils are discussed. In § 2, the technical realization of the BPM, the experimental test stand, as well as the calibration procedure are described. Sec. IV summarizes the results of the investigations carried out at the test stand. The results of the measurements obtained after installation in the COSY storage ring are described in § 2.4, followed by the conclusions and outlook in Sec. VI. Detailed derivations of the signal induced in a quarter coil are discussed in Appendix A, the resonance frequency of a quarter coil in Appendix B and the effect of mirror currents in Appendix C.
Toroidal coils as beam position monitors
General considerations
Coils wound on a toroidal coil body are called Rogowski coils, named after Walter Rogowski[17]. Such devices are used as AC current transformers and as beam current monitors, taking advantage of the fact that due to Ampere’s law, the induced voltage in the coil is independent of the position of the current-carrying wire passing through it[18, 19, 20, 21]. Rogowski coils are ideally suited for the application as BPMs because the magnetic flux lines of a current-carrying straight wire form concentric circles around the wire and penetrate the cross-sectional area of the windings of the Rogowski coil at right angles, resulting in an optimal induced potential difference between the ends of the coil.
Position response of differential coil setup
The magnetic difference signal of two identical induction coil sensors is a measure of the position of the beam between them, as derived in this section. The magnetic flux density generated by the beam current can be written as
where is a unit vector along the circumference, is the vacuum magnetic permeability and is the radial distance from the beam center. As shown in Figure 1, the beam is perpendicular to the plane defined by the two coils.
Figure 1. Beam position response of two identical induction coils (1 and 2). The axis points along the direction of the beam current . The change of the induced magnetic flux and , probed by the two coils, is sensitive to the displacement of the beam from the center .
The time derivative of the induced flux in two identical short induction coils, 1 and 2, located on a circle of diameter is given by
where denotes the cross-sectional area of the coils. The ratio of induced voltage difference to voltage sum in the two coils is therefore given by
The above considerations also apply to rotationally symmetric charge distributions of the beam, as discussed in more detail in Sec. II C.
The above derivation illustrates that a suitably segmented toroidal coil may serve as a BPM. Due to symmetry considerations, the induced voltage difference is an odd function of the beam displacement, thus yielding a linear relationship for small displacements, as illustrated in Eq. (3). A toroidal coil segmented into four elements, as indicated in Figure 2, allows one to simultaneously determine the beam position along two orthogonal coordinate axes. This specific segmentation will be discussed further in this publication.
Figure 2. Toroidal coil of radius , segmented into four quadrants (). The (beam) current passes through the coil along the axis. The induced voltage in one quarter is measured by a device with an input impedance of (see also equivalent circuit diagram in Figure 3).
Evaluation of the flux in a quarter coil
For the calculation of the flux encircled by the windings on the torus, we start from the vector potential , which is linked to the beam current density via Poisson’s equation. Using cylindrical coordinates, , and , one finds
when displacement currents are neglected. If the beam current has only a component in -direction, as shown in Figure 1, the same holds for the vector potential , and
we can regard the problem as two-dimensional. Furthermore, we consider here beams with rotationally symmetric current distributions that are much smaller than the coil diameter , so that no beam particles intercept the Rogowski coil. Such a current distribution generates a field in its outside region that bears no information about the radial current distribution, and is therefore equivalent to a pencil beam. In this case, the remaining component of the vector potential is a harmonic function outside the beam, i.e., , which is given by the logarithm of the distance to the beam. Thus, in cylindrical coordinates we arrive at the ansatz
In order to find the induced flux, an integration of along the wire path has to be performed.
The calculation of the induced magnetic fluxes in the four quadrants , discussed in Appendix A, yields a power expansion in terms of the beam displacements and . The corresponding induced voltages for any Fourier component of the periodic beam current in the storage ring are given by differentiation, which is conveniently carried out in the frequency domain by using .
Making use of Eq. (43) considering the amplitudes
where the frequency response is included because the quarter coil is operated in a resonance regime. Using Eq. (A18) one obtains for the induced voltage in a quadrant
where ,
is the number of windings and denotes the ratio of small radius to large radius of the toroid (see Table I and Figure 17). The geometric functions are defined in Eq. (A17), listed in Table III, and analytical expressions for the are given in Table IV in Appendix A. For vanishing beam displacements , the remaining describes the common voltage induced in each of the quadrants. The frequency response is discussed in § 2 D and App. B.
Figure 17. Representation of the beam coordinates and , as given in cylindrical coordinates in Eq. (24), and the location of one specific coil winding. The axis points along the beam direction. The coil center coincides with the center of the coordinate system in the plane, the toroid is described by the two radii and . The two variables used for the integration are and . The functional dependence of is given in Eq. (23).
| 0 | 1 | 2 | 3 | 0 | 1 | 2 | 3 | ||
| 1 | |||||||||
| 2 | 0 | 0 | 0 | 0 | |||||
| 3 | |||||||||
| 4 | 0 | 0 | 0 | 0 | |||||
| 5 | |||||||||
| 6 | 0 | 0 | 0 | 0 |
Table III. Analytical expressions for the terms (Eq. (A17)) and the coefficients and , defined in Eq. (27), for the four quadrants up to order for a coil covering an angle starting at , i.e. . For small values of , .
| 0 | 1 | 2 | 3 | |
| 1 | ||||
| 2 | ||||
| 3 | ||||
| 4 | ||||
| 5 | ||||
| 6 |
Table IV. Analytical expressions for the terms from Eq. (A19) for the four quadrants up to order for partial coverage of the quadrants.
The symmetries that apply to the induced flux in the different quadrants are passed on to the induced voltages of the quadrants [see Eq. (37)]. Given the induced voltage from Eq. (7), one can write for the induced voltages in the other quadrants,
Therefore, assuming identical segments, the sum over the voltages of all quadrants is independent of the beam displacements,
This property makes it possible to monitor the current of a bunched beam with an unsegmented Rogowski coil.
Small beam displacements can adequately be described by the linear term in Eq. (7), corresponding to in the sum. Thus, to lowest order
The linear term in the displacements , is the basis for the operation of opposed quadrants or halves as BPMs, if the corresponding signals are subtracted.
Frequency response
Before we discuss in § 2 the specifics of the design of a BPM based on a segmented toroidal Rogowski coil, the frequency response of such a system shall briefly be addressed. The basic setup of a toroidal coil that is split into four individual quadrants is shown in Figure 2. The equivalent circuit diagram for a single quadrant coil coupled to the beam circuit is depicted in Figure 3.
Figure 3. Equivalent circuit diagram for one toroidal coil quadrant with inductance , as shown in Figure 2. A voltage is induced due to the inductive coupling of the beam inside the coil. The resistance of the quadrant coil is , and its capacitance is mostly due to the connecting wires. represents the input impedance of the preamplifier.
The voltage due to the induction by the orbiting bunched beam is modified by the resistance of the coil wire, by the inductance of the coil, and by the capacitance . The latter is mostly due to the connecting wires. The revolution frequency of the beam is low enough to treat these components as lumped elements, as shown in the equivalent circuit diagram in Figure 3. The resistor describes the input impedance of the measuring device.
The lumped elements, , , , and constitute a resonant circuit. Its frequency response with the values given in Table I is calculated in Appendix B. This yields for a quarter coil an estimated resonant frequency of .
One would ideally operate the coil quarters at resonance to take advantage of the amplified voltage in order to improve the signal-to-noise ratio. The disadvantage is that small shifts in the resonance frequency due to external conditions (e.g. temperature drifts) would lead to large changes in the amplifying factors of the four coils. Due to manufacturing tolerances the four resonance curves are not absolutely identical, which would therefore lead to changes in the position measurement. For this reason the decision was made to operate them off-resonance.
The Rogowski coils were designed for operation at a frequency of , i.e. with four bunches orbiting in the storage ring at a revolution frequency of . The final experiment was carried out in a single-bunch mode, thus calibrations and measurements were performed at , i.e. far away from the resonance frequency. The resonant frequency of each coil was adjusted to match the revolution frequency of the beam by placing an appropriate capacitor in parallel to the coil.
| Parameter | Value |
| Number of quadrants | 4 |
| Toroid large radius | |
| Toroid small radius | |
| Ratio parameter | |
| Wire diameter | |
| Windings per quadrant | |
| Angular coverage | |
| Capacitance per quadrant (wiring) | |
| Inductance per quadrant | |
| Resistance of quarter coil | |
| Input impedance | |
| Resonance frequency (estimated) | |
| Beam momentum | |
| Revolution frequency | |
| Lorentz factor | |
| Number of stored particles | |
| Corresponding beam current |
Table 1. Parameters of the Rogowski coil design. The electrical parameters , , and are calculated in Appendix B. Typical beam parameters for a momentum are listed. denotes the elementary charge.
Experimental realization
Physical parameters of the Rogowski BPM
The Rogowski BPM described here consists of four equal coil segments, as illustrated in Figure 4, ⓐ. The four corresponding voltage signals of the preamplifiers[22] ⓕ can be combined electronically to yield the differential signals of two sets of opposing half coils, which serve to simultaneously determine the beam displacement in and in direction.
Figure 4. Internal structure of the setup of the toroidal coil support in the test stand, depicted in Figure 6: ⓐ Toroidal quarter coils on torus, ⓑ coil supporting torus (PEEK), ⓒ coil support rings (PEEK), ⓓ DN 100/150 CF coil support flange ⓔ fiducial mark, ⓕ coaxial feedthrough with preamplifier, ⓖ DN 150 CF beam line vacuum tubes, ⓗ rotary flange, and ⓘ current carrying wire.
PEEK plastic (Polyether ether ketone, material properties are given in https://pubchem.ncbi.nlm.nih.gov/compound/19864017) was chosen as the material for the coil body, because of its low cost, good machineability and low outgassing rates in vacuum. The earlier used Vespel® material (For material properties, see https://www.dupont.com/products/vespel.html) proved worse in terms of price, and showed higher outgassing rates, mostly due to absorbed water. The coil body features both a groove along its outer circumference and small radial bore holes for the returning quarter coil wires and their fixation, respectively.
The inner and outer diameter of the toroid onto which the Rogowski coils are wound amount to 105 mm and 129 mm, respectively, sufficiently large to avoid any obstruction of the beam inside the circular beam tube diameter of 150 mm in the COSY straight sections. The Kapton-insulated copper wire for the sensor coils has a diameter of 450 . The number of windings () determines the inductance of the quarter sensor coil and thus its resonant frequency, as discussed in Sec. II D. The calculated ohmic resistance of the coil is . The inductance can be estimated from the textbook formula
of a straight coil with the same length, which yields a value of .
To install the coil in the CF 160 flange, it is clamped between two PEEK rings held together by screws of the same material. Each coil features a twisted wire pair of 10 cm length followed by a 16 cm long SMA cable leading to an SMA feedthrough on a CF 16 flange. Figure 5 shows a photograph of the fully assembled BPM as it was used both on the test bench and in the storage ring.

Figure 5. Photograph of the Rogowski-BPM installed in the rotary flange as shown in Figure 4. The coil covers an angle . Note that
Test stand for the Rogowski BPM
The laboratory test stand, shown in Figure 6, has been developed for the purpose of conditioning and calibrating Rogowski BPMs prior to the installation at COSY. The BPM is fixed on top of a stepper motor-driven -table ⓚ ⓛ in order to displace it laterally with respect to a current carrying tin-coated (corrosion-free) copper wire ⓘ, which mimics the particle beam in COSY. A sinusoidal current from a signal generator (Keysight 33522B Waveform Generator, Keysight Technologies, www.keysight.com) of about 100 in amplitude represents the dominant Fourier component of the COSY beam current at the revolution frequency of 750 kHz. The wire of about 1 m length is fixed on one side in a -table ⓜ for angular adjustment and on the other side it is guided by a roll and pulled by a weight in a water bath to assure a constant tension on the wire without creating vibrations. It is terminated by a resistor.
Figure 6. Experimental setup to test and commission the Rogowski-type BPMs. The internal structure of the BPM is shown in Figure 4. ⓓ DN 100/150 CF coil support flange, ⓔ fiducial mark, ⓕ coaxial feedthrough with preamplifier, ⓖ DN 150 CF beam line vacuum tubes, ⓗ rotary flange of the rf Wien filter, ⓘ current carrying wire, ⓙ tool with knife edges and fiducial marks (see Figure 8), ⓚ vertical () stepper-motor drive, ⓛ horizontal () stepper-motor drive, ⓜ manual -table for angular adjustment of the current-carrying wire, and ⓝ weight in water bath to stretch the wire and to damp its oscillations.
Tubes on both sides of the flange are added to mimic the electrical surroundings of the BPM in COSY. The stepper motors (LIMES 150-100-MiSM-IMS produced by OWIS GmbH, www.owis.eu) move the coil in the -plane during a calibration measurement. They have a maximum travel range of 100 mm, a load capacity of 60 kg and a positioning error of . The repeatability of a specific position is better than 500 nm, the resolution of 50 nm is limited by an encoder for each axis.
The analog signals from the coils are fed into custom-made preamplifiers[23] with gain factors of about 18, measured at 750 kHz. The amplified signals are analyzed by lock-in amplifiers (Zurich Instruments HF2LI Lock-in Amplifier 50 MHz, 210 MSa/s www.zhinst.com) using the TTL signals from a second signal generator of the same type as reference (Figure 7). This was necessary to avoid cross talk between the original signal and the reference signal when using two channels of the same device. Both generators were coupled to each other to assure that the generated frequencies were identical.
Figure 7. Electric circuit diagram for the measurements with the experimental test setup as shown in Figure 6.
The analog-to-digital converters feature a resolution of 14 bit. A measurement bandwidth of 6.81 Hz with a fourth-order low-pass filter is typically used for signal processing. This entails a time constant of about 10 ms. The demodulator needs a 10 times larger time to reach 99% of the output level, which means that we are dealing with a minimum integration time of about 100 ms.
Calibration of the Rogowski BPM
For the relative calibration the device is moved relative to the current carrying wire using the stepper motors while the response of the quarter coils is processed by the readout electronics. A map is recorded covering the central part of the space inside the device (see Sec. IV C).
The absolute calibration is done using the insertion shown in Figure 8. This insertion was manufactured to determine the exact position of the wire during the calibration measurements. It consists of a structure which positions a knife edge in the plane of the Rogowski torus and fiducial marks to be used for a laser tracking system. The exact geometry was surveyed by a measuring machine (ZEISS UPMC850, Carl Zeiss QEC GmbH www.zeiss.de) to an accuracy of . This insertion can be installed at any time making use of the slits in the discs without changing the position of the current wire. The wire is put at a voltage potential and a programmed routine moves the Rogowski BPM with the insertion until the wire touches the knife edge. Using the known geometry of the insert, the readings of the -tables and a laser tracker (OMNITRAC 2, Automated Precision Inc. www.apimetrology.com), the absolute position of the measured calibration maps can be connected to the fiducial marker located on top of the Rogowski BPM (see Figure 6) with an accuracy of . After installation of the BPM in COSY the position of the fiducial mark is determined within the COSY lattice using a laser tracker. Thus the absolute position of the particle beam within the COSY lattice can be determined with an accuracy defined by the accuracy of the measurement of the laser tracker, which is about 50 to 100 .
Figure 8. Knife edge tool with knife edges j1 and fiducial marks j2, quarter coils a wound on the torus b. The current carrying wire is denoted by i.
Vacuum compatibility
Besides the accuracy of the position measurement, the compatibility with the vacuum standards of the accelerator is crucial. All components of the Rogowski coil were cleaned and baked before assembly. In order to test the vacuum compatibility before installation in the accelerator, a vacuum test stand was set up, which consists of a bakeable chamber that is pumped by a 250 l/s turbomolecular pump (comparable to the pumping speed at the installation point in the accelerator). A quadrupole mass analyzer was used to determine the composition of the rest gas in the chamber.
The use of PEEK as material for the coil body and the Kapton coated wire for the coils yielded small outgassing rates. The pressures reached after baking at 120 °C for a week are mbar. The mass spectrum before baking showed a dominant water peak. After baking the water is removed from the structure and the wire. To minimize water accumulation on the BPM during installation in the ring, the time it was exposed to air was minimized.
Attention was paid to the temperature during the baking process, as this takes place after the calibration of the coil (which was carried out in air, see § 2 C and Figure 6). The reason for this is that both the Kapton-coated wire and the PEEK plastic adsorb water in air. To ensure that baking did not alter the calibration values, several test calibrations were carried out before and after baking, which showed that there was no difference in the calibration values within previously mentioned accuracy.
Investigations using the test stand
Impedance measurement of a quarter coil
In order to characterize one quarter coil according to the circuit diagram of Figure 3 an impedance measurement was performed using a network analyzer (Siglent SVA 1032X, SIGLENT Technologies www.siglenteu.com).
The influence of the connection cable outside the vacuum vessel was taken into account in the calibration, so that the results, shown in Figure 9 represent the coil with the connection wires up to the vacuum flange (see Figure 4). The preamplifier was not used for this measurement. The impedance of the coil can be expressed by
Figure 9. Combined fit to the amplitude and phase data from the network analyzer according to Eq. (11).
where , and are the respective properties of the circuit, shown in Figure 3. The amplitude and phase of Eq. (11) were used in a combined fit to determine these properties (Figure 9). To improve the fit an additional offset of the phase, was introduced as a parameter. The value amounts to degrees. For the amplitude relative error of 5% was assumed, for the phase the assumed error is 1 degree. These errors were estimated from the RMS of several measurements at the same frequency. The overall is 540. The amplitude contributes with 85 and the phase plot with 455 to the value. The number of degrees of freedom is 160 (data points) - 4 (parameters) = 156. A possible correlation between amplitude and phase data is not taken into account. The resulting properties are the ohmic resistance , the inductance and the capacitance . The DC resistance of the coil was measured to be about 1 . For a copper wire used in the experiment due to the skin effect one expects an ohmic resistance increase by a factor of 4, roughly in agreement with the fit parameters.
Measurement of resonant behavior of a quarter coil
The resonant behaviour of a quarter coil was measured on the test setup, shown in Figure 6 using a wire to mimic the beam current. The induced current in the four coils were amplified and analyzed in lock-in amplifiers (see § 2 B). The result for one quarter coil is shown in Figure 10. The amplitude and phase are given by Eqs. (43) and (B3).
Figure 10. Combined fit to the amplitude and phase data of one Rogowski coil excited by the current-carrying wire on the test stand.
To better fit the data, the heuristic parameters , and were introduced, yielding
where
These additional parameters account for other resonances present in the system and for the skin/proximity effect[24]. Due to the strong correlation between and , the value of was fixed to the value from the impedance fit. An
TABLE II. Parameters of the fit to the resonance data in Figure 10.
input impedance of the preamplifiers of was assumed. The results are summarized in Table II.
| Fit Parameter | Value |
| fixed | |
| fixed | |
Table II.
For the a relative error of 1% was assumed, for the phase the assumed error is 1 degree. The is 52.4 and has a contribution of 16.3 from the amplitude and 36.1 from the phase. The number of degrees of freedom is .
The equivalent circuit of Figure 3, together with the additional parameters discussed above, describes the data very well. The increased resistance and capacitance compared to the impedance measurement are due to the preamplifier.
It was noticed that due to manufacturing tolerances the resonance curves slightly differed for the four coils. This resulted in a strong frequency dependence of the calibration. To reduce this effect variable capacitors were installed, which shifted the resonance frequencies of all coils to a common value.
Calibration measurement of the BPM
The calibration measurement was carried out as described in § 2 C. A map of points is measured in the -plane in the range . The four voltages of Eqs. (7), (8) were recorded and processed as follows. We define:
Using from Eq. (9), the ratios and are shown as a function of and , respectively, in Figure 11. For better visibility of the data the graphs are shifted proportionally by the respective and values. The first order linear behavior clearly dominates. To get a good description of the data by the theory additional parameters were introduced: The fit includes terms up to 4th order in (see Appendix A). Despite of the clamping mechanism of the torus a perfect alignment angle could not be guaranteed, therefore an angle was added by which the -coordinate system of the coils was rotated around the -axis. The coils themselves are not exactly equal, therefore small relative scaling coefficients for the voltages for three of the coils with respect to the fourth were introduced. From the RMS of repeated measurements the error on was estimated to be . With this error assumption a -minimization resulted in values of 19.5 and 7.5 for the ratios and , respectively, for 441 (measurement points) 20 (parameters) 421 degrees of freedom (ndf). The low /ndf indicates that the errors on were probably overestimated.
Figure 11. Calibration map with the measured and values depending on the respective and positions set with the stepping drives of the -table. For better visibility the graphs are shifted by the respective and values.
From the fitted parameters to model , one can now reconstruct and and compare it with selected and values. This is shown in Figure 12. The residuals (reconstructed - selected) are of the order of few m.
Figure 12. Residuals: reconstructed − selected vs. (top) and reconstructed − selected vs. (bottom).
The linear coefficient of Figure 11 can be derived from Eqs. (8) - (10) to:
but the fitted values , which could also be estimated directly from Figure 11, are substantially higher. This originates in the surrounding of the coil.
was calculated for an air coil in an environment free of conducting material. Since the Rogowski coils are installed inside the beam tube (Figure 4) secondary induction due to mirror currents on the inner surface of the beam tube needs to be considered. This effect is included in the coefficient (see Appendix C, eq. (C8))
with the inner radius of the beam pipe mm. This estimate is based on the simple geometry of a straight beam tube and explains qualitatively the difference between the fitted value and the calculated value of an air coil in Eq. 16.
Figure 14. before (a) and after (b) offset correction. Without the correction a drift depending on the beam current was observed in contrast to the measurements in the laboratory. The offset correction eliminates this dependence.
Installation at COSY
After the calibration (Sec. IV C) and baking procedure (§ 2 D) the coil was installed at the storage ring COSY. It was noticed that an additional offset voltage present at zero beam current appeared. This offset disturbed the position measurements, so that the position readings depended on the beam current, as shown in Figure 13a and 14a. The offset is due to stray fields of the COSY cavity which is located at a distance of 9 m from the Rogowski coils. The cavity is defining the COSY revolution frequency which is also used as a reference frequency of the lock-in amplifier.
Figure 13. before (a) and after (b) offset correction. Without the correction a drift depending on the beam current was observed in contrast to the measurements in the laboratory. The offset correction eliminates this dependence.
The offset was determined by extrapolating the measured voltages to zero beam current as can be seen for in Figure 15. The interception of the straight line fit with the vertical axis yields the respective voltage offset corrections , , , . The subtraction of these offset values from the measured voltages resulted in beam current independent position values as expected from the calibration measurements in the laboratory (Figure 13b and 14b). Note that a change of in the voltage ratio as shown in these figures corresponds to a change in position of . It can be seen that the error on a single measurement of a 1 s time interval is also of a similar amount, corresponding to a resolution of 5 .
Figure 15. Example of the induced voltage as a function of the COSY beam current . The additional offset, due to stray fields, was determined by extrapolation to zero beam current.
The Rogowski BPM was used during several experimental beam times by the JEDI collaboration in order to determine the position of the COSY deuteron beam. Figures 16 show the measured beam position in horizontal and vertical direction for five consecutive cycles for the Rogowski coil (52x, 52y) and a conventional COSY BPM (6x, 6y).
Conclusion and outlook
We described the development of a new type of beam position monitor based on a Rogowski coil. It reaches a resolution of 5 in 1 s time interval. The absolute accuracy is determined by the alignment accuracy of about 50 . One advantage over classical capacitive BPMs is the short insertion length of these devices. In an energy-variable machine, the frequency-dependent amplification of the Rogowski BPMs limits its sensitivity, because away from the resonance the amplitude decreases. In the specific case of a fixed-energy EDM machine, however, this presents an advantage because, with optimized design, the resonance amplifies the signals.
While our development uses four toroidal coils, in principle, the device could be divided into more segments in order to study higher-order components of the transverse particle beam distribution. Note that with the four-fold segmentation presented here a quadrupole component could already be studied. A pair of higher segmented Rogowski coils at a distance in the storage ring may offer the possibility to measure the phase space distribution of the particle beam. The individual quarter coils have been measured separately in our investigations to yield the required differential voltage electronically after subtraction. A better read out scheme may be established by a direct galvanic connection between opposing quarters in order to inherently be sensitive to the differential signal without having to deal with the dominant contribution of the beam current represented by the term in Eq. (10). This may also entail the development of a dedicated pre-amplifier for this purpose. Also, the cross talk between neighboring coils due to the induced currents can be reduced.
Acknowledgments
This work has been performed in the framework of the JEDI collaboration, and is financially supported by an ERC Advanced-Grant (srEDM # 694390) of the European Union.
We are very grateful to Jürgen Böker, Hans-Joachim Krause, Stefan Hintzen, Andrea Pesce, Thomas Sefzick and Jamal Slim for their support.
Figure 16. Measured horizontal (52x) and vertical beam positions (52y) during five consecutive cycles in COSY. For comparison the horizontal (vertical) position measurement of the next conventional COSY BPM (6x,6y) 4 m downstream in beam direction is shown. The lower plots show the beam current. Note that the drifts are in opposite directions which is caused by quadrupole magnets in between the two devices.
Detailed derivations
Involving Stokes’ theorem, the calculation of the magnetic flux due to the beam current enclosed by the winding surfaces of a quarter coil with index can be expressed by the line integral of the vector potential over the boundary of the surface ,
The approach using the vector potential seems to be advantageous compared to the use of the -field, because in this case, we only have to deal with the single component in order to obtain the enclosed magnetic flux. Furthermore, via Stokes’ theorem, one integration less is required.
Derivation of magnetic flux induced in a quadrant coil
The surface of the torus with given values for and , as shown in Figure 17, is parameterized in terms of the two angles and according to
The wire does not cover the surface of the torus entirely but follows a path given by a linear relation between the two angles and
Due to the fact that the vector potential has only a component along the -direction, we only need the -component of the differential line element along the coil winding, which is obtained by differentiation
Furthermore one has to consider that the coils do not cover the full torus. The angles involved are indicated in Figure 5.
The integral in Eq. (18) can be further simplified, yielding for the flux induced in a quadrant ,
where
as shown in Figure 17. In the last line of Eq. (22), the sum over the discrete angle values of is represented by an integral, which is an adequate description for a densely wound coil. In cylindrical coordinates, the vector potential has already been introduced in Eq. (5), in which the beam displacement from the center is parameterised in cylindrical coordinates
Eq. (5) can be written as
where the latter part describes the decomposition into a Fourier series[25] (Eq. 3.152), for . For a beam current monitor without segmentation of the toroidal coil, the integration over must be performed from to .
Eq. (25) shows that all the cosine terms yield vanishing contributions in this case. Therefore, the information about the beam displacement encoded in (see Eq. (24)) vanishes as well. A full Rogowski coil without segmentation therefore constitutes a beam current monitor, its sensitivity being entirely described by the last logarithmic term in Eq. (25), which depends only on the coil geometry. For a toroidal coil segmented into four quadrants , each covering , however, the first integration over required in Eq. (22) yields
where the coefficients
are functions of the angle (see Table III). The dependence on of the arguments of the trigonometric functions can be eliminated using a sum over the sine and cosine functions, related to the beam displacements and , via Eq. (24). It follows with these trigonometric relations from [26] (1.331-1 and 1.331-3) that
where, e.g., . In terms of the displacements, parameterized using Eq. (24), one can then write
The missing integration over according to Eq. (22), taking into account Eq. (23), yields the magnetic flux
The position-dependent functions are defined below in Eq. (A19). The integral in Eq. (A13) can be solved by partial integration and the use of reference[26] (3.644-4).
with .
The induced flux in segment can be written as
The remaining integral in Eq. (A15),
is required for and can be evaluated by recursion, as explained in Sec. A 2.
With the substitutions
the induced flux in quadrant can be written as
The position-dependent terms are given by
Analytic expressions for the functions and the coefficients and are listed in Table III, and for the functions in Table IV, up to order .
The symmetry relations for the in the different quadrants , given in Table IV, apply to all orders in and are passed on to the induced magnetic flux in a quadrant. Thus, given a magnetic flux in quadrant of , one can write for the induced fluxes in the other quadrants,
Please note the equivalence to Eq. (8).
Recursion formula for
The difference of two consecutive functions is found to be proportional to the derivative of the first one.
Thus, the -th function can be obtained from the -th function by recursion via
where, following Eq. (A16), for the function starting the recursion is found to be
Magnetic flux in one quadrant without displacement
Without displacements of the beam with respect to the center of the toroidal coil, i.e., for , the magnetic flux in Eq. (A18) is entirely given by the first term, yielding the well-known result
that the magnetic flux is equal to the product of the number of coil windings , magnetic flux density at a distance of and the enclosed winding area . (In the second line, we have made use of the fact that , see Table I.)
Resonance frequency of quarter toroid
The numerical calculation of the resonance frequency is carried out using the equivalent circuit diagram shown in Figure 3. The relation of the measured output voltage to the beam induced voltage can be described in the frequency domain using the picture of a voltage divider, which leads to
The amplitude can be written as
and the phase is given by:
To estimate and in this circuit we consider the inner and outer radii of the toroidal coil
using and , as listed in Table I.
The nominal outer wire diameter is given by
its insulation is thick, i.e., the diameter of the current-carrying wire is . The angle between two wire centers seen from the center of the toroid amounts to
The maximum number of windings of a fully wound quadrant coil is therefore given by
In order to estimate the inductance of a quarter coil, we quote the textbook formula for a long, straight and densely wound coil
where is the number of windings of the quarter toroid, and is the length of the coil along its inner radius. denotes the cross section of the coil. Here the permeability of vacuum is
and the relative permeability of the material of the coil body is close to unity.
As shown in Figure 5, the coils do not cover the quadrants completely, and instead of , given in Eq. (48), the real
number of windings used in a quarter coil amounted to
The corresponding real inductance of a partially wound coil with the above given number of windings corresponds to
The capacitances of the twisted connecting wires are estimated like in a parallel plate capacitor using a length and a plate separation of
yielding
where the vacuum permittivity is
These twisted wires are soldered to a 17 cm long coaxial cable with an specific capacity of 96 pF/m, resulting in a capacity of . This ammounts to a total capcity
An estimate of the resonance frequency of a quarter of a Rogowski coil using the specified geometrical and physical parameters given above, yields
The resistance of a coil quarter amounts to
where for the conductivity of copper after winding, a value of
was used.
The function from Eq. (43) is plotted in Figure 18 using the values for , , , and listed in Table I. For an input impedance of , a quality factor for the operation of a quarter coil near the resonance of
Figure 18. Plot of the frequency response function from Eq. (43) using , , , and given in Table I. The resonance frequency is given in Eq. (57), and the estimated quality factor .
can be estimated.
Effect of mirror currents
The distribution of the image current density for a pencil beam depends on its position 1.
with ,
where the delta-function has been introduced to state that the current density is confined to the inner tube surface because of the skin effect. The inner radius of the beam tube is denoted by , and the beam coordinates and are defined in Eq. (24). On integrating one finds that the total current on the wall matches exactly the beam current .
A pick-up coil like a segmented Rogowski coil does not only capture the magnetic field of the beam, but also that of the wall currents, which constructively adds to the primary contribution by the beam, because they flow on the other side of the coils in reverse direction. The total flux through a coil due to the wall currents can be found similar to the discussion of Eq. (18). Equation (5) is a special case of the more general expression of the vector potential for a two-dimensional current distribution
which for the wall currents takes the form
with .
In order to find the lowest order term () in the displacement we can expand both the fraction and the logarithm (see Eq. (25))
and see that only the product of the two cos-terms yields the desired contribution.
Analogous to Eq. (22) the flux induced in the quadrant coil is obtained by the integration over its surface
with the coefficients and defined in Eq. (27). In particular
This flux adds to the primary one from the beam current, see Eq. A18. There the term in brackets has its beam current counterpart in
which is about half the value in brackets for a Rogowski quarter coil close to the beam tube . This explains in part the about 50% higher value of the linear term of the induced voltage with respect to the displacement found experimentally, see the discussion following Eq.17.
References
- [1]M. Pospelov and A. Ritz, Annals of Physics 318, 119 (2005), special issue.
- [2]B. Robson, Journal of High Energy Physics, Gravitation and Cosmology 04, 166 (2018).
- [3]W. Bernreuther, “CP violation and baryogenesis,” in CP Violation in Particle, Nuclear and Astrophysics, edited by M. Beyer (Springer Berlin Heidelberg, Berlin, Heidelberg, 2002) pp. 237–293.
- [4]F. Abusaif, I. Keshelashvili, K. Grigoryev, D. Mchedlishvili, L. Jorot, J. Pretz, U.-G. Meißner, A. Kulikov, A. Stahl, O. Felden, S. Martin, R. Stassen, P. Wüstner, A. Aksen- tev, O. Javakhishvili, E. Valetov, H. Soltner, B. Alberdi- Esuain, R. Talman, V. Shmakova, A. Kacharava, D. Hölscher, G. Ciullo, F. Müller, A. Silenko, R. Gebel, B. Lorentz, G. Na- tour, D. Grzonka, M. Zurek, J. Hetzel, P. Zupranski, S. Sid- dique, A. Magiera, I. Ciepal, C. Böhme, N. Nikolaev, S. Dymov, A. Lehrach, M. Gaisser, A. Wrońska, D. Heberling, M. Con- talbrigo, V. Kamerdzhiev, E. Stephenson, N. Nass, C. Weide- mann, Y. Senichev, M. Schott, J. Ritman, A. Wirzba, M. Beyß, M. Haj Tahar, M. Ströher, I. Koop, C. Carli, A. Lamont, M. Berz, J. Böker, A. Pesce, G. Tagliente, C. Käseberg, A. Saleev, T. Wag- ner, K. Makino, A. Aggarwal, J. Slim, D. Prashun, G. Macha- rashvili, J. Borburgh, N. Lomdize, V. Ponсza, D. Shergelashvili, M. Gagoshidze, M. Tabidze, S. Karanth, K. Laihem, T. Hah- nraths, P. Lenisa, V. Hejny, N. Giese, T. Sefzik, L. Barion, J. Michaud, A. Nogga, H. Straatmann, Y. Uzikov, S. Basile, F. Rathmann, A. Atanasov, Z. Metreveli, M. Rosenthal, Y. Val- dau, M. Simon, and J.-M. De Conto, CERN Yellow Report , 257 (2021).
- [5]F. Rathmann, A. Saleev, and N. Nikolaev (JEDI, srEDM), J. Phys. Conf. Ser. 447, 012011 (2013).
- [6]W. M. Morse, Y. F. Orlov, and Y. K. Semertzidis, Phys. Rev. ST Accel. Beams 16, 114001 (2013).
- [7]F. Rathmann, N. N. Nikolaev, and J. Slim, Phys. Rev. Accel. Beams 23, 024601 (2020).
- [8]R. Maier, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 390, 1 (1997).
- [9]C. Weidemann et al., Phys. Rev. ST Accel. Beams 18, 020101 (2015).
- [10]T. Wagner, A. Nass, J. Pretz, F. Abusaif, A. Aggarwal, A. Andres, I. Bekman, N. Canale, I. Ciepal, G. Ciullo, F. Dahmen, S. Dymov, C. Ehrlich, R. Gebel, K. Grigoryev, D. Grzonka, V. Hejny, J. Hetzel, A. Kacharava, V. Kamerdzhiev, S. Karanth, I. Keshelashvili, A. Kononov, A. Kulikov, K. Laihem, A. Lehrach, P. Lenisa, N. Lomidze, A. Magiera, D. Mchedlishvili, F. Müller, N. Nikolaev, A. Pesce, V. Ponсza, F. Rathmann, M. Retzlaff, A. Saleev, M. Schmühl, D. Shergelashvili, V. Shmakova, J. Slim, A. Stahl, E. Stephenson, H. Ströher, M. Tabidze, G. Tagliente, R. Talman, Y. Uzikov, Y. Valdau, and A. Wrońska, Journal of Instrumentation 16, T02001 (2021).
- [11]M. Wendt, IEEE Instrumentation & Measurement Magazine 24, 21 (2021).
- [12]J. Slim, R. Gebel, D. Heberling, F. Hinder, D. Hölscher, A. Lehrach, B. Lorentz, S. Mey, A. Nass, F. Rathmann, L. Reif- ferscheidt, H. Soltner, H. Straatmann, F. Trinkel, and J. Wolters, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 828, 116 (2016).
- [13]F. Hinder, H.-J. Krause, H. Soltner, and F. Trinkel, in 4th International Beam Instrumentation Conference (2016).
- [14]F. Abusaif, Development of compact, highly sensitive beam po- sition monitors for storage rings, Ph.D. thesis, RWTH Aachen University (2021).
- [15]D. Berners, L. Reginato, AIP Conf. Proc. 281, 168 (1992).
- [16]S. Hacıömeroğlu, D. Kawall, Y.-H. Lee, A. Matlashov, Z. Omarov, and Y. K. Semertzidis, PoS ICHEP2018, 279 (2019).
- [17]W. Rogowski and W. Steinhaus, Archiv für Elektrotechnik 1, 141 (1912).
- [18]W. Nassisi and A. Luches, Review of Scientific Instruments 50, 900 (1979).
- [19]D. G. Pellinien, M. S. Di Capua, S. E. Sampayan, H. Gerbracht, and M. Wang, Review of Scientific Instruments 51, 1535 (1980), https://doi.org/10.1063/1.1136119.
- [20]R.-Y. Han, W.-D. Ding, J.-W. Wu, H.-B. Zhou, Y. Jing, Q.-J. Liu, Y.-C. Chao, and A.-C. Qiu, Review of Scientific Instruments 86, 035114 (2015), https://doi.org/10.1063/1.4916094.
- [21]H. Samimi, A. Mahari, M. A. Farahnakian, and H. Mohseni, IEEE Sensors Journal 15, 651 (2015).
- [22]S. Merzliakov, C. Böhme, and V. Kamerdzhiev, IKP Annual Report, Forschungszentrum Jülich (2016).
- [23]C. Böhme, I. Bekman, V. Kamerdzhiev, B. Lorentz, M. Simon, and C. Weidemann, in 6th International Beam Instrumentation Conference (2018).
- [24]F. Terman, Radio Engineer’s Handbook, McGraw-Hill handbooks (McGraw-Hill Book Company, Incorporated, 1943).
- [25]J. D. Jackson, Classical Electrodynamics (Wiley, 1975).
- [26]I. S. Gradshteyn, I. M. Ryzhik, D. Zwillinger, and V. Moll, Table of integrals, series, and products; 8th ed. (Academic Press, Amsterdam, 2014).