betaFeedback

WorksPhysics and Astronomy

Improved measurements of neutron lifetime with cold neutron beam at J-PARC

Abstract

The ``neutron lifetime puzzle'' arises from the discrepancy between neutron lifetime measurements obtained using the beam method, which measures decay products, and the bottle method, which measures the disappearance of neutrons. To resolve this puzzle, we conducted an experiment using a pulsed cold neutron beam at J-PARC. In this experiment, the neutron lifetime is determined from the ratio of neutron decay counts to 3^3He(n,p)3^3H reactions in a gas detector. This experiment belongs to the beam method but differs from previous experiments that measured protons, as it instead detects electrons, enabling measurements with distinct systematic uncertainties. By enlarging the beam transport system and reducing systematic uncertainties, we achieved a fivefold improvement in precision. Analysis of all acquired data yielded a neutron lifetime of τn=877.2 ± 1.7(stat.) −3.6+4.0(sys.)τ_{\rm n}=877.2~\pm~1.7_{\rm(stat.)}~^{+4.0}_{-3.6}{}_{\rm (sys.)} s. This result is consistent with bottle method measurements but exhibits a 2.3σσ tension with the average value obtained from the proton-detection-based beam method.

Introduction

A neutron decays into three particles, a proton, an electron, and an antineutrino via weak interactions. The neutron β\beta decay lifetime, τn\tau_{\mathrm{n}}, is a crucial parameter that determines the neutron-to-proton ratio at the onset of Big Bang nucleosynthesis (BBN) [1, 2]. The combination of the BBN model and the baryon-to-photon ratio derived from the cosmic microwave background observations [3, 4] provides an accurate prediction of the abundance of light elements, allowing tests of physical phenomena in the early universe. Additionally, the VudV_{\mathrm{ud}} term in the Cabibbo-Kobayashi-Maskawa (CKM) matrix can be determined using τn\tau_{\mathrm{n}} and λ\lambda, which is the ratio of axial-vector to vector coupling constants, gA/gVg_{\mathrm{A}}/g_{\mathrm{V}}, independently of nuclear models. Revised radiative corrections in 2018 [5] suggested the CKM unitarity violation exceeding 2σ2\sigma [6], emphasizing the importance of the measurement of the neutron lifetime. Precise data on τn\tau_{\mathrm{n}} is also valuable for testing lattice QCD calculations of gAg_{\mathrm{A}} [7].

Neutron lifetime has been measured using two primary methods. The first is the beam method [8, 9], where neutron β\beta decay products, specifically protons in these references, are counted relative to the number of incident neutrons, yielding an average lifetime of τnbeam=888.0±2.0 s\tau_{\mathrm{n}}^{\mathrm{beam}} = 888.0 \pm2.0\ \mathrm{s}. The second is the bottle method [10, 11, 12, 13, 14, 15, 16, 17], which measures the disappearance of ultra-cold neutrons (UCNs) confined in a container over time, producing an average value of τnbottle=878.4±0.5 s\tau_{\mathrm{n}}^{\mathrm{bottle}} = 878.4 \pm0.5\ \mathrm{s}. The 9.59.5-s (4.6σ4.6\sigma) discrepancy between the two methods is known as the “neutron lifetime puzzle” [18], raising concerns about the reliability of neutron lifetime measurements.

Possible causes for this discrepancy include unaccounted systematic uncertainties, such as protons from neutron decay undergoing charge exchange with residual gas [19], though this effect is considered negligible [20]. The 9.59.5-s, approximately 1%1\% discrepancy between beam and bottle methods has caused discussions of theories such as UCN inelastic scattering with dark matter [21], hydrogen atom formation [22], mirror neutron transitions [23], or neutron decay into dark matter [24]. Upcoming experiments [25, 26, 27, 28], including space neutron detections [29, 30], may help resolve this issue.

To address the neutron lifetime puzzle, we conducted neutron lifetime measurements using the high-intensity pulsed neutron beamline at Japan Proton Accelerator Research Complex (J-PARC), adopting the method of Kossakowski et al. [31]. This experiment detects electrons from neutron β\beta decay, offering a distinct observable compared to previous proton-counting beam methods [8, 9], and thus provides an alternative approach to verify the neutron lifetime puzzle. Our first result in 2020, τn=898−18+15\tau_n = 898^{+15}_{-18} (stat.) (sys.) s [32], was consistent with both beam and bottle methods. Through improved neutron intensity by a new neutron transport and reduced systematic uncertainties, we achieved a fivefold improvement in precision, as discussed in this paper.

Principle of the experiment– The experiment, conducted at the polarized neutron beam branch of BL05/NOP at J-PARC Materials and Life Science Experimental Facility [33, 34], is illustrated schematically in Figure 1. The pulsed neutron beam is shaped into 40-cm-long bunches using a spin flip chopper (SFC) [35, 36, 37] and introduced into a 1-m-long time projection chamber (TPC) [38]. Measuring β\beta decay events while the neutron bunch is fully within the TPC reduces uncertainties in detection efficiency and effects from the background.

Schematic of the BL05/NOP beamline and time projection chamber

Figure 1. The top view of BL05/NOP. Pulsed neutrons entering from the beam port on the left are shaped into bunches by the spin flip chopper and then directed into the time projection chamber.

The TPC is filled with an He+CO2_2 gas with a mixture of 85:15, optimized for low neutron scattering and efficient electron multiplication. This setup achieves a trigger efficiency of over 99.9% for neutron β\beta decay events. A precise amount of 3He{}^{3}\mathrm{He}, corresponds to the pressure of 50 mPa, is added using a volumetric expansion method, and 3He(n,p)3H{}^{3}\mathrm{He}(\mathrm{n},\mathrm{p}){}^{3}\mathrm{H} reactions are used to determine the number of incident neutrons. The inner walls of the beam duct and TPC are covered with a shielding material made of a mixture of 6Li{}^{6}\mathrm{Li}-enriched LiF and polytetrafluoroethylene (PTFE) in a 30:70 weight ratio [39]. This cover effectively reduces background γ\gamma radiation produced by neutron capture.

The neutron lifetime is derived using the detected β\beta decay count SβS_\beta, the 3He(n,p)3H{}^{3}\mathrm{He}(\mathrm{n},\mathrm{p}){}^{3}\mathrm{H} reaction count SHeS_{\mathrm{He}}, their respective detection efficiencies εβ\varepsilon_\beta and εHe\varepsilon_{\mathrm{He}}, the number density of 3He{}^{3}\mathrm{He} in the detector ρ\rho, and the 3He(n,p)3H{}^{3}\mathrm{He}(\mathrm{n},\mathrm{p}){}^{3}\mathrm{H} reaction cross-section σ0\sigma_0 at the neutron velocity v0=2200v_0 = 2200 m/s, according to the following equation [32]:

τn=1ρσ0v0(SHe/εHeSβ/εβ).(1)\tau_n = \frac{1}{\rho\sigma_0 v_0}\left(\frac{S_{\mathrm{He}}/\varepsilon_{\mathrm{He}}}{S_\beta/\varepsilon_\beta}\right). \tag*{(1)}

The β\beta decay events and 3He(n,p)3H{}^{3}\mathrm{He}(\mathrm{n},\mathrm{p}){}^{3}\mathrm{H} events are identified using waveform and track information from the TPC.

The neutron lifetime is calculated from their count ratio and detection efficiencies, determined by using Monte Carlo simulations (MCs) based on Geant4.9.6 [40].

Updates– We conducted experiments with improvements to the apparatus and analysis based on the 2020 results [32]. A major source of systematic uncertainties was background γ\gamma rays from the absorption reactions of neutrons scattered by the TPC working gas. To address this, we reduced the gas pressure to mitigate neutron scattering and its associated effects. Lower pressures made the TPC more prone to electrical discharge, necessitating reduced signal amplification. By minimizing electrical noise and optimizing the operating conditions, we successfully obtained stable measurements at 50 kPa, reduced from the original pressure of 100 kPa. In addition, simulations were developed to reproduce these low-pressure conditions, incorporating specific wire efficiency and space charge. These simulations thereby enable reliable measurements at 50 kPa. The low-pressure measurements further improved the accuracy of determining the 3He{}^{3}\mathrm{He} content in the working gas and also reduced background events caused by nuclear reactions with CO2_2, namely 12C(n,γ)13C{}^{12}\mathrm{C}(\mathrm{n},\gamma){}^{13}\mathrm{C} and 17O(n,α)14C{}^{17}\mathrm{O}(\mathrm{n},\alpha){}^{14}\mathrm{C}.

The TPC operating gas used is commercially available high-grade He gas (G1He) containing 0.1 ppm of 3He{}^{3}\mathrm{He} [32]. Previously, the amount of 3He{}^{3}\mathrm{He} was determined by analyzing G1He using a mass spectrometer [41, 42]. After measuring the 14N(n,p)14C{}^{14}\mathrm{N}(\mathrm{n},\mathrm{p}){}^{14}\mathrm{C} reaction cross section with a precision of 0.4% [43], we established a method to determine the 3He{}^{3}\mathrm{He}/4He{}^{4}\mathrm{He} ratio in G1He with an accuracy of better than 0.8% by performing measurements with He+CO2_2 gas mixed with N2_2 gas [44]. We also improved the method for determining the amount of 3He{}^{3}\mathrm{He} introduced into the TPC vacuum vessel. In this experiment, 50 mPa of 3He{}^{3}\mathrm{He} gas is precisely injected using a buffer vessel with a known volume ratio to the vacuum chamber. By employing two pressure gauges with different dynamic ranges and an optimized buffer volume, the measurement precision of the volume ratio improved from 0.34% to 0.12%. Consequently, the accuracy of ρ\rho determination at 50 kPa was enhanced to 0.13% [44].

These methods have been adopted since 2019. We use an SFC to bunch neutrons incident to the TPC. The neutron intensity was previously limited by the size of the neutron mirrors of the SFC [35]. The upgraded SFC, featuring larger magnetic supermirrors and spin flippers, increased the neutron intensity to the TPC by a factor of 2.8 while maintaining a signal-to-noise ratio of 250–400 [35, 36, 37]. Measurements were performed under four conditions: two gas pressures (100 kPa and 50 kPa) and two SFC configurations (old and new SFC). Table I summarizes the dataset, comprising 49 gas fills measured between 2014 and 2023. Each gas fill represents a measurement of approximately one week, including energy calibration with a 55Fe^{55}\mathrm{Fe} source, drift time calibration using cosmic rays, neutron lifetime measurements with beam passage, and background measurements with a beam shutter closed. During the measurement, the beam alternated periodically between a beam pass run (1000–1200 s) and a beam dump run (800–1000 s).

ConditionsYearGas fillBeam cycle
100 kPa/old SFC2014–2019294660
50 kPa/old SFC2017–201861044
100 kPa/new SFC2021–20235671
50 kPa/new SFC2021–202391729

Table I. Measurements for each condition, presented as the number of gas fills and beam cycles (defined as one beam pass run and one dump run).

Analysis– The analysis follows the method of previous measurements [32]. Two parameters, XEX_E and XCX_C are introduced to separate β\beta decay events from the background. Here, XEX_E is the distance between the near endpoint of a track and the central wire, while XCX_C indicates the distance from the closest hit to the center, expressed in wire spacing units (Figure 2). Since neutron β\beta decay events originate from the beam region (40 mm), the signal region was defined as XE<5X_E < 5 (< 60 mm). On the other hand, the region XC≥5X_C \ge5 contains almost no events originating from neutron β\beta decay and was therefore defined as the background region.

Figure 2. Conceptual downstream view of the TPC illustrating XEX_E (distance from the near endpoint of a track to central wire) and XCX_C (distance from closest hit to its center). Number of wires and beam size are not to scale.

The primary background in this experiment arises from (n,γ)(n,\gamma) events caused by neutrons scattered by the TPC working gas. The number of background events to be subtracted can be obtained by multiplying the number of events in the background region by the ratio of those entering the signal region to those in the background region. This ratio is determined using MCs. A larger background than predicted by MC simulations was observed, amounting to 4.9–5.4% of SβS_\beta at 100 kPa (vs. 1.2–1.3% predicted) and 3.1–3.3% at 50 kPa (vs. 0.65–0.67%). While the cause remains unclear, leakage of scattered neutrons through gaps in the 6^{6}LiF tile is suspected. To model this background, we selected MCs assuming discrete γ\gamma ray energies that best reproduced the experimental results. Since the single-energy distribution used in the previous method [32] could not reproduce the background shape or the energy loss per unit length (dE/dx\mathrm{d}E/\mathrm{d}x) distribution, we constructed MCs with γ\gamma rays with two energy components. The γ\gamma ray energies were determined to reproduce the two-dimensional distribution of XEX_E and XCX_C outside the signal region. The origins of the γ\gamma rays were considered: “Internal,” for neutron absorption within the 6^{6}LiF tile shielding, and “Internal-external,” for absorption within and outside the shielding. The “Internal-external” model, with 200 keV contributing 91.9(8)% and 5000 keV contributing 8.1(8)%, showed the best fit to the experimental data with the χ2\chi^2 per degrees of freedom (DOF) of 208.8/202.

Signal cut uncertainties were evaluated by varying the XEX_E cut from 4 to 11 ch (5 ch as baseline), with a maximum variation of 0.2% in the data-to-MC event ratio (Figure 3). Energy cut uncertainties, estimated from dE/dx\mathrm{d}E/\mathrm{d}x differences for cosmic rays, contributed less than 0.1%. These improvements ensured accurate background subtraction and enhanced the reliability of neutron β\beta-decay measurements.

Figure 3. XEX_E distribution for 50 kPa/new SFC. Black points represent measured data, and colored regions represent the stacked MC distributions. From top to bottom: red (β\beta), yellow (gas-scattered 5000 keV γ\gamma rays), green (gas-scattered 200 keV γ\gamma rays), magenta (γ\gamma rays scattered by the 6^{6}LiF tile shutter), and blue (β\beta events from gas-scattered neutrons).

The W-value, the average energy required for single-electron ionization, in the He+CO2_2 gas of a proton (WpW_{\mathrm{p}}) increases as proton energy decreases below 1 keV unlike electron ionization (WeW_{\mathrm{e}}) [45]. We previously addressed the effect by simplifying the quenching factor as q(E)=We(E)/Wp(E)=1q(E)=W_{\mathrm{e}}(E)/W_{\mathrm{p}}(E)=1 with kinetic energy EE, while accounting for the impact of q(E)=0q(E)=0 as a 0.6% systematic uncertainty. Improved statistics now make this effect significant, thus q(E)q(E) value from SRIM [46], ranging from 0.2 to 0.6 for 25–750 eV protons, were adopted. This adjustment reduced MC detection efficiency εβ\varepsilon_\beta by up to 0.3%, with a systematic uncertainty of 0.1% based on differences between W-values from SRIM and at which MCs give best fits.

Pileup events were estimated based on count rates. The full pileup rate corresponds to a lifetime change of 0.4%. We evaluated the classification of primary pileup events, triggered by a β\beta decay electron and a 3^{3}He event follows, by developing a dedicated MC simulation that generates events at different timings. This improved the classification accuracy, reducing the pileup uncertainty to +0.17/-0.07%.

Results– To mitigate human bias, a random variation of ±10%\pm10\% has been applied to ρ\rho during the updated analysis, which was removed only after the analysis method and parameters had been finalized. Data were grouped into four conditions based on gas pressure (100 kPa and 50 kPa) and SFC type (old and new), with average neutron lifetimes summarized in Table II. For each condition, uncertainties related to cut positions were evaluated independently, while globally correlated uncertainties were applied as common shifts. The overall neutron lifetime result from J-PARC, combining all conditions, is τn=877.2±1.7(stat.)−3.6(sys.)+4.0\tau_n = 877.2 \pm1.7_{\mathrm{(stat.)}}{}^{+4.0}_{-3.6_{\mathrm{(sys.)}}}. The combining average yielded χ2/DOF=15.8/3\chi^2/\mathrm{DOF} = 15.8/3, though the underlying cause of this deviation remains undetermined.

ConditionsValueStat.Cut positionOther sys.
100 kPa/old SFC870.93.5+1.8/-2.8+5.5/-4.9
100 kPa/new SFC868.34.0+1.5/-2.9+3.8/-3.2
50 kPa/old SFC868.27.7+2.7/-0.9+4.8/-3.9
50 kPa/new SFC884.82.4+0.8/-1.3+3.2/-3.0
Combined877.21.7+4.0/-3.6

Table 2. Neutron lifetime values for each gas pressure (100 kPa, 50 kPa) and SFC configuration (new, old), with averages. Units in seconds.

The main uncertainties in this measurement are summarized in Table III, with the largest contribution from the gas-scattering neutron background. The effect due to the cut position uncertainties are small (0.9 s) due to good agreement between MC simulations and exper-

EffectUncertainty
Statistic1.7
Cut position0.9
Gas-induced background+1.1/-2.0
Pile up+1.5/-0.6
Contamination from 12^{12}C(n,γ\gamma)13^{13}C+1.7/-0.0
γ\gamma-ray scattering at LiF shutter1.3
Unbunched neutron from SFC+1.1/-1.0
Inject 3^{3}He1.2
3^{3}He in G1He+1.5/-1.4
3^{3}He(n,p)3^{3}H cross section1.2
Total systematic+4.0/-3.6

Table 3. List of uncertainties with units in seconds.

imental results. The 12^{12}C(n,γ\gamma)13^{13}C reaction, where 12^{12}C in the CO2_2 gas absorbs neutrons, produces 13^{13}C with a 4946 keV γ\gamma ray and a 1.0 keV recoil. Misclassification of these events as β\beta decay was evaluated using MC simulations, with uncertainties near the energy threshold included in the systematic uncertainty. The effect due to scattering of γ\gamma rays at the 6^{6}LiF tile shutter was modeled using PHITS3.20 [47] and NaI detector measurements. This contributed to a 1.3 s systematic uncertainty. The effect of unbunched neutrons caused by SFC imperfections, leading to detection efficiency mismatches for β\beta and 3^{3}He(n,p)3^{3}H events at the TPC edges, was simulated to evaluate their impact and incorporated as systematic uncertainties. The uncertainties in introduced 3^{3}He and G1He-contained 3^{3}He were incorporated into ρ\rho. For 50 kPa operations, 14^{14}N-based measurements limited the uncertainty to 0.5 s, while mass spectrometer data increased it to 1.5 s. The 3^{3}He(n,p)3^{3}H cross section, 5333 ±\pm 7 barn [48] obtained by averaging two experiments [49, 50], contributed 1.2 s of uncertainty.

The neutron lifetime obtained in this study, with statistical and systematic uncertainties combined in quadrature is shown in Figure 4, along with results from previous experiments [6]. Our value is consistent with the bottle method but shows a 2.3σ\sigma tension with the average of the proton-counting beam method. Combining our results with other beam measurements gives τnbeam=886.0±1.8\tau_n^{\mathrm{beam}} = 886.0 \pm1.8, reducing the discrepancy with the bottle method to 4.0σ\sigma.

Figure 4. Measured neutron lifetimes in this work and previous experiments [6]. Red circles represent measurements using the proton-detection-based beam method, blue squares represent the bottle method, and the red and blue bands indicate the averages of these two methods. The open circle represents the measurement from this work at J-PARC.

Conclusion and outlook– To address the “neutron lifetime puzzle,” arising from discrepancies between neutron lifetimes measured by the beam method (via decay products) and the bottle method (via disappearance), we measured the neutron lifetime from the ratio of electrons from neutron decay to 3^{3}He(n,p)3^{3}H reactions. Unlike previous beam method experiments that detected protons, this experiment introduced distinct systematic uncertainties.

By enlarging the SFC aperture, the neutron intensity increased by a factor of 2.8, enabling high-statistics data acquisition and achieving a statistical precision of 1.7 s. Systematic uncertainties were reduced to 4 s by accurately modeling gas-scattered neutron backgrounds. Combining all data, the neutron lifetime was determined as τn=877.2±1.7(stat.)−3.6(sys.)+4.0\tau_n = 877.2 \pm1.7_{\mathrm{(stat.)}}{}^{+4.0}_{-3.6_{\mathrm{(sys.)}}} s. This result aligns with the bottle method and is 10.8 s shorter than the averaged value of proton-counting beam method, exhibiting 2.3σ2.3\sigma tension in the results of the beam method.

The primary limitation of this experiment is the γ\gamma ray background from gas-scattered neutrons in the TPC. To suppress this background, the upcoming LiNA experiment [51, 52] will apply a solenoidal magnetic field to the TPC. This setup is expected to reduce background events by a factor of 50. Furthermore, the reduction of background will decrease the required measurement time to one-third, while the uncertainty due to pileup is also anticipated to decrease to one-third as a result of its shorter drift length.

Acknowledgments

We sincerely thank Prof. Y. Namito and H. Hirayama for the discussions on Geant4 specifications, and Prof. M. Hino for fabricating the neutron supermirror for the SFC. This work was supported by JSPS KAKENHI Grant Numbers (JP19GS0210, 23244047, 24654058, 26247035, 16H02194, 18H01231, 19H00690, 21H04475, and 22H00140), and JST, the establishment of university fellowships towards the creation of science technology innovation, Grant Number JPMJFS2136. The neutron experiment at the Materials and Life Science Experimental Facility of J-PARC was performed under user programs (Proposal Nos. 2014B0271, 2015A0316, 2016A0168, 2016B0272, 2017A0230, 2017B0332, 2018A0297, 2018B0272, 2019A0223, 2019B0341, 2020A0223, 2021B0287, 2022A0117, 2022B0325, 2023A0184, 2023B0253, and 2024A0331) and an S-type projects of KEK IMSS (Proposal Nos. 2014S03 and 2019S03). This experiment is supported as stage-1 status (E100) of J-PARC-PAC KEK IPNS.

References

References

  1. [1]G. J. Mathews, T. Kajino, and T. Shima, Big bang nucleosynthesis with a new neutron lifetime, Phys. Rev. D 71, 021302 (2005).DOI
  2. [2]T. Chowdhury and S. Ipek, Neutron lifetime anomaly and Big Bang nucleosynthesis, Can. J. Phys. 102, 96 (2024).DOI
  3. [3]C. L. Bennett, D. Larson, J. L. Weiland, N. Jarosik, G. Hinshaw, N. Odegaard, K. Smith, R. Hill, B. Gold, M. Halpern, et al., Nine-year Wilkinson Microwave Anisotropy Probe (WMAP) observations: final maps and results, Astrophys. J., Suppl. Ser. 208, 20 (2013).
  4. [4]N. Aghanim, Y. Akrami, F. Arroja, M. Ashdown, J. Au-mont, C. Baccigalupi, M. Ballardini, A. J. Banday, R. Barreiro, N. Bartolo, et al., Planck 2018 results-I. Overview and the cosmological legacy of Planck, Astron. Astrophys. 641, A1 (2020).
  5. [5]C.-Y. Seng, M. Gorchtein, H. H. Patel, and M. J. Ramsey-Musolf, Reduced Hadronic Uncertainty in the Determination of $V_{ud}$, Phys. Rev. Lett. 121, 241804 (2018).DOI
  6. [6]S. Navas et al. (Particle Data Group Collaboration), Review of Particle Physics, Phys. Rev. D 110, 030001 (2024).
  7. [7]C.-C. Chang, A. N. Nicholson, E. Rinaldi, E. Berkowitz, N. Garron, D. A. Brantley, H. Monge-Camacho, C. J. Monahan, C. Bouchard, M. A. Clark, et al., A per-cent-level determination of the nucleon axial coupling from quantum chromodynamics, Nature 558, 91 (2018).DOI
  8. [8]J. Byrne, P. D. Berry, C. G. Habeck, S. J. Smidt, J. Spain, and A. P. Williams, A revised value for the neutron lifetime measured using a Penning trap, Europhys. Lett. 33, 187 (1996).
  9. [9]A. T. Yue, M. S. Dewey, D. M. Gilliam, G. L. Greene, A. B. Laptev, J. S. Nico, W. M. Snow, and F. E. Wietfeldt, Improved Determination of the Neutron Lifetime, Phys. Rev. Lett. 111, 222501 (2013).DOI
  10. [10]A. Serebrov, V. Varlamov, A. Kharitonov, A. Fomin, Y. Pokotilovski, P. Geltenbort, J. Butterworth, I. Krasnoshekova, M. Lasakov, R. Tal'Daev, A. Vassiljev, and O. Zherebtsov, Measurement of the neutron lifetime using a gravitational trap and a low-temperature Fomblin coating, Phys. Lett. B 605, 72 (2005).
  11. [11]A. Pichlmaier, V. Varlamov, K. Schreckenbach, and P. Geltenbort, Neutron lifetime measurement with the UCN trap-in-trap MAMBO II, Phys. Lett. B 693, 221 (2010).DOI
  12. [12]A. Steyerl, J. Pendlebury, C. Kaufman, S. S. Malik, and A. Desai, Quasielastic scattering in the interaction of ultracold neutrons with a liquid wall and application in a reanalysis of the Mambo I neutron-lifetime experiment, Phys. Rev. C: Nucl. Phys. 85, 065503 (2012).DOI
  13. [13]S. Arzumanov, L. Bonderenko, S. Chernyavsky, P. Geltenbort, V. Morozov, V. Nesvizhevsky, Y. Panin, and A. Strepetov, A measurement of the neutron lifetime using the method of storage of ultracold neutrons and detection of inelastically up-scattered neutrons, Phys. Lett. B 745, 79 (2015).
  14. [14]A. P. Serebrov, E. A. Kolomensky, A. K. Fomin, I. A. Krasnoshchekova, A. V. Vassiliev, D. M. Prudnikov, I. V. Shoka, A. V. Chechkin, M. E. Chaikovskiy, V. E. Varlamov, et al., Neutron lifetime measurements with a large gravitational trap for ultracold neutrons, Phys. Rev. C 97, 055503 (2018).DOI
  15. [15]R. W. Pattie, N. B. Callahan, C. Cude-Woods, E. R. Adamek, L. J. Broussard, S. M. Clayton, S. A. Currie, E. B. Dees, X. Ding, E. M. Engel, et al., Measurement of the neutron lifetime using a magneto-gravitational trap and in situ detection, Science 360, 627 (2018).DOI
  16. [16]V. F. Ezhov, A. Andreev, G. Ban, B. Bazarov, P. Geltенbort, A. Glushkov, V. Knyazkov, N. A. Kోవrizhnykh, G. Krygin, O. Naviliat-Cuncic, et al., Measurement of the neutron lifetime with ultracold neutrons stored in a magneto-gravitational trap, JETP Lett. 107, 671 (2018).arxiv.org/abs/1412.7434
  17. [17]F. M. Gonzalez, E. Fries, C. Cude-Woods, T. Bailey, M. Blatnik, L. Broussard, N. Callahan, J. Choi, S. Clayton, S. Currie, et al. (UCNτ Collaboration), Improved neutron lifetime measurement with UCNτ, Phys. Rev. Lett. 127, 162501 (2021).DOI
  18. [18]G. Greene and P. Geltenbort, A puzzle lies at the heart of the atom, Sci. Am. 314, 36 (2016).
  19. [19]A. Serebrov, M. Chaikovskii, G. Klyushnikov, O. Zherebtsov, and A. Chechkin, Search for explanation of the neutron lifetime anomaly, Phys. Rev. D 103, 074010 (2021).DOI
  20. [20]F. E. Wietfeldt, R. Biswas, J. Caylor, B. Crawford, M. S. Dewey, N. Fomin, G. L. Greene, C. O. Haddock, S. F. Hoogerheide, H. P. Mumm, et al., Comment on “Search for explanation of the neutron lifetime anomaly”, Phys. Rev. D 107, 118501 (2023).
  21. [21]S. Rajendran and H. Ramani, Composite solution to the neutron lifetime anomaly, Phys. Rev. D 103, 035014 (2021).DOI
  22. [22]E. Oks, New results on the two-body decay of neutrons shed new light on neutron stars, New Astron. 113, 102275 (2024).DOI
  23. [23]Z. Berezhiani, Neutron lifetime puzzle and neutron-mirror neutron oscillation, Eur. Phys. J. C 79, 1 (2019).DOI
  24. [24]B. Fornal and B. Grinstein, Dark matter interpretation of the neutron decay anomaly, Phys. Rev. Lett. 120, 191801 (2018).DOI
  25. [25]S. Materne, R. Picker, I. Altarev, H. Angerer, B. Franke, E. Gutsmiedl, F. Hartmann, A. Müller, S. Paul, and R. Stoepfler, PENeLOPE—on the way towards a new neutron lifetime experiment with magnetic storage of ultra-cold neutrons and proton extraction, Nucl. Instrum. Methods Phys. Res., Sect. A 611, 176 (2009).DOI
  26. [26]W. Wei, A new neutron lifetime experiment with cold neutron beam decay in superfluid helium-4, J. Phys. G:Nucl. Part. Phys. 47, 125101 (2020).DOI
  27. [27]J. Auler, M. Engler, K. Franz, J. Kahlenberg, J. Karch, N. Pfeifer, K. Roß, C. Strid, N. Yazdan doost, E. Adamek, et al., τSPECT: a spin-flip loaded magnetic ultracold neutron trap for a determination of the neutron lifetime, J. Phys. G:Nucl. Part. Phys. 51, 115103 (2024).DOI
  28. [28]M. Krivoš, N. Floyd, Z. Tang, C. Morris, M. Blatnik, S. Clayton, C. Cude-Woods, A. Holley, D. Hooks, T. Ito, et al., Cerium doped yttrium aluminum perovskite scintillator as an absolute ultracold neutron detector, Review of Scientific Instruments 95, 10.1063/5.0211059 (2024).DOI
  29. [29]J. T. Wilson, D. J. Lawrence, P. N. Peplowski, V. R. Eke, and J. A. Kegerreis, Measurement of the free neutron lifetime using the neutron spectrometer on NASA’s Lunar Prospector mission, Phys. Rev. C 104, 045501 (2021).DOI
  30. [30]N. Tsuji, T. Enoto, H. Nagaoka, Y. Kato, K. Taniguchi, M. Hareyama, Y. Otake, Y. Wakabayashi, T. Takanashi, C. Iwamoto, et al., Moon Moisture Targeting Observatory (MoMoTaRO) for basic science application to neutron lifetime measurement, in Proceedings of 38th International Cosmic Ray Conference (ICRC2023) - Cosmic-Ray Physics (Indirect, CRI), Vol. 444 (2023) p. 296.
  31. [31]R. Kossakowski, P. Grivot, P. Liaud, K. Schreckenbach, and G. Azuelos, Neutron lifetime measurement with a helium-filled time projection chamber, Nucl. Phys. A 503, 473 (1989).DOI
  32. [32]K. Hirota, G. Ichikawa, S. Iki, T. Ino, Y. Iwashita, M. Kitaguchi, R. Kitahara, J. Koga, K. Mishima, T. Mogi, K. Morikawa, A. Morishita, N. Nagakura, H. Oide, H. Okabe, H. Otono, Y. Seki, D. Sekiba, T. Shima, H. M. Shimizu, N. Sumi, H. Sumino, T. Tomita, H. Uehara, T. Yamada, S. Yamashita, K. Yano, M. Yokohashi, and T. Yoshioka, Neutron lifetime measurement with pulsed cold neutrons, Prog. Theor. Exp. Phys. 2020, 123C02 (2020).
  33. [33]K. Mishima, T. Ino, K. Sakai, T. Shinohara, K. Hirota, K. Ikeda, H. Sato, Y. Otake, H. Ohmori, S. Muto, et al., Design of neutron beamline for fundamental physics at J-PARC BL05, Nucl. Instrum. Methods Phys. Res., Sect. A 600, 342 (2009).DOI
  34. [34]K. Nakajima, Y. Kawakita, S. Itoh, J. Abe, K. Aizawa, H. Aoki, H. Endo, M. Fujita, K. Funakoshi, W. Gong, et al., Materials and Life Science Experimental Facility (MLF) at the Japan Proton Accelerator Research Complex II: Neutron Scattering Instruments, Quantum Beam Sci. 1, 9 (2017).
  35. [35]K. Taketani, T. Ebisawa, M. Hino, K. Hirota, T. Ino, M. Kitaguchi, K. Mishima, S. Muto, H. Oide, T. Oku, et al., A high S/N ratio spin flip chopper system for a pulsed neutron source, Nucl. Instrum. Methods Phys. Res., Sect. A 634, S134 (2011).DOI
  36. [36]G. Ichikawa, Y. Fuwa, T. Hasegawa, M. Hino, K. Hirota, T. Ino, Y. Iwashita, M. Kitaguchi, J. Koga, S. Matsuzaki, et al., Neutron lifetime experiment with pulsed cold neutrons at J-PARC, in Proceedings of Particles and Nuclei International Conference 2021 — PoS(PANIC2021), Vol. 380 (2022) p. 457.DOI
  37. [37]K. Mishima, G. Ichikawa, Y. Fuwa, T. Hasegawa, M. Hino, R. Hosokawa, T. Ino, Y. Iwashita, M. Kitaguchi, S. Matsuzaki, et al., Performance of the Fully Equipped Spin Flip Chopper for the Neutron Lifetime Experiment at J-PARC, Prog. Theor. Exp. Phys. 2024, 093G01 (2024).
  38. [38]Y. Arimoto, N. Higashi, Y. Igarashi, Y. Iwashita, T. Ino, R. Katayama, M. Kitaguchi, R. Kitahara, H. Matsumura, K. Mishima, et al., Development of time projection chamber for precise neutron lifetime measurement using pulsed cold neutron beams, Nucl. Instrum. Methods Phys. Res., Sect. A 799, 187 (2015).DOI
  39. [39]J. Koga, S. Iki, A. Kimura, M. Kitaguchi, R. Kitahara, K. Mishima, N. Nagakura, T. Okudaira, H. Otono, H. Shimizu, et al., Measurement of gamma rays from 6LiF tile as an inner wall of a neutron-decay detector, J. Instrum. 16, P02001 (2021).
  40. [40]J. Allison, K. Amako, J. Apostolakis, P. Arce, M. Asai, T. Aso, E. Bagli, A. Bagulya, S. Banerjee, G. Barrand, et al., Recent developments in Geant4, Nucl. Instrum. Methods Phys. Res., Sect. A 835, 186 (2016).
  41. [41]H. Sumino, K. Nagao, and K. Notsu, Highly sensitive and precise measurement of helium isotopes using a mass spectrometer with double collector system, J. Mass Spectrom. Soc. Jpn. 49, 61 (2001).DOI
  42. [42]K. Mishima, H. Sumino, T. Yamada, S. Ieki, N. Nagakura, H. Otono, and H. Oide, Accurate determination of the absolute 3He/4He ratio of a synthesized helium standard gas (helium standard of Japan, HESJ): toward revision of the atmospheric 3He/4He ratio, Geochem. Geophys. Geosyst. 19, 3995 (2018).DOI
  43. [43]R. Kitahara, K. Hirota, S. Ieki, T. Ino, Y. Iwashita, M. Kitaguchi, J. Koga, K. Mishima, A. Morishita, N. Nagakura, et al., Improved accuracy in the determination of the thermal cross section of 14N(n,p)14C for neutron lifetime measurement, Prog. Theor. Exp. Phys. 2019, 093C01 (2019).
  44. [44]T. Mogi, T. Hasegawa, K. Hirota, G. Ichikawa, S. Ieki, T. Ino, Y. Iwashita, S. Kajiwara, Y. Kato, M. Kitaguchi, et al., Improvement of systematic uncertainties for the neutron lifetime experiment at J-PARC, in Proceedings of Particles and Nuclei International Conference 2021 — PoS(PANIC2021), Vol. 380 (2022) p. 458.
  45. [45]I. Katsioulas, P. Knights, and K. Nikolopoulos, Ionisation quenching factors from w-values in pure gases for rare event searches, Astropart. Phys. 141, 102707 (2022).DOI
  46. [46]J. F. Ziegler, M. D. Ziegler, and J. P. Biersack, SRIM—The stopping and range of ions in matter (2010), Nucl. Instrum. Methods Phys. Res., Sect. B 268, 1818 (2010).
  47. [47]Tatsuhiko Sato and Yosuke Iwamoto and Shintaro Hashimoto and Tatsuhiko Ogawa and Takuya Furuta and Shin-ichiro Abe and Takeshi Kai and Pi-En Tsai and Norihiro Matsuda and Hiroshi Iwase and Nobuhiro Shigyo and Lembit Shiver and Koji Niita, Features of Particle and Heavy Ion Transport code System (PHITS) version 3.02, J. Nucl. Sci. Technol. 55, 684 (2018).DOI
  48. [48]S. F. Mughabghab, Atlas of Neutron Resonances: Resonance Parameters and Thermal Cross Sections. Z= 1-100 (Elsevier, Amsterdam, 2006).
  49. [49]J. Als-Nielsen and O. Dietrich, Slow Neutron Cross Sections for He3, B, and Au, Phys. Rev. 133, B925 (1964).
  50. [50]V. P. Alfimenkov, G. G. Akopyan, J. Wierzbicki, A. M. Govorov, L. B. Pikel’ner, and E. Sharapov, Neutron scattering lengths for 3He, Yad. Fiz. 25, 1145 (1977) [Sov. J. Nucl. Phys. 25, 1145 (1977) (English translation)].
  51. [51]H. Otono, LiNA–Lifetime of neutron apparatus with time projection chamber and solenoid coil, Nucl. Instrum. Methods Phys. Res., Sect. A 845, 278 (2017).DOI
  52. [52]N. Sumi, G. Ichikawa, K. Mishima, Y. Makida, M. Kitaguchi, S. Makise, S. Matsuzaki, T. Nagano, M. Tanida, H. Uehara, et al., The LiNA experiment: Development of multi-layered time projection chamber, Nucl. Instrum. Methods Phys. Res., Sect. A 1045, 167586 (2023).DOI

Paper details

vlnc:W_46v4n9wb
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 10

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents