betaFeedback

WorksPhysics and Astronomy

Optimal Estimation in Weak Value Amplification with a Position Pointer

Abstract

We experimentally evaluate five estimators for weak-value amplification (WVA) using a position pointer to measure birefringence time delays. Two general approaches are considered: measuring the position shift ΔxΔx and measuring the probability change ΔPwΔP_w of successful postselection. Specifically, five estimators are investigated: CCD-detected fringe shift ΔxΔx, quadrant photodiode (PDQ) transversal voltage difference (XDIFF), and lock-in amplifier output phase ηη (for ΔxΔx measurement), as well as PDQ total output voltage (SUM) and CCD-detected average photon number NrN_r (for ΔPwΔP_w measurement). The measurement precision is characterized by the Allan deviation over a range of input laser powers P0P_0. Generally, measuring the position shift ΔxΔx yields higher precision than measuring the probability change ΔPwΔP_w. At P0=0.5P_0=0.5~mW, corresponding to a laser-power-limited regime, direct measurement of the fringe displacement with the CCD achieves a minimum Allan deviation of (5.30±0.10)×10−3(5.30\pm0.10)\times10^{-3}~as, approaching the corresponding photon-statistical Cramér–Rao bound (CRB). At P0=50P_0=50~mW, corresponding to a detector-limited regime, PDQ detection combined with lock-in demodulation provides the best precision, reaching (1.80±0.06)×10−3(1.80\pm0.06)\times10^{-3}~as and remaining close to the corresponding CRB. These results demonstrate that the optimal readout depends on the available optical power, detector dynamic range, and technical noise, providing practical guidance for selecting readout strategies in high-precision WVA-based metrology.

Weak value amplification (WVA) [1, 2, 3, 4, 5] has enabled ultra-sensitive measurement of minute physical quantities, including the photonic spin Hall effect [6, 7, 8], transverse optical displacements [9, 10], ultra-weak magnetic fields [11], single-photon nonlinearity [12, 13], angular rotations [14], and longitudinal phase shifts [15, 16, 17, 18, 19]. It is now widely accepted that WVA outperforms conventional measurement in the presence of various noise sources and detector saturation effects [12, 20, 21, 22, 23, 24].

In WVA, an interaction described by the unitary evolution U^=exp⁡(−igA^⊗p^)\hat{U} = \exp\left(-ig\hat{A}\otimes\hat{p}\right) couples a two-level system ∣Ψ⟩\lvert\Psi\rangle to a pointer ∣Φ⟩\lvert\Phi\rangle, where A^\hat{A} is the observable quantity and gg, the coupling strength, is the parameter we wish to estimate. In principle, the near-orthogonality of pre- and postselected states ∣Ψi⟩\lvert\Psi_i\rangle and ∣Ψf⟩\lvert\Psi_f\rangle will simultaneously yield a large weak value and a low probability of successful postselection: Aw=⟨Ψf∣A^∣Ψi⟩/⟨Ψf∣Ψi⟩A_w = \langle\Psi_f\lvert\hat{A}\lvert\Psi_i\rangle/\langle\Psi_f\lvert\Psi_i\rangle, Pw=∣⟨Ψf∣Ψi⟩∣2P_w = \lvert\langle\Psi_f\lvert\Psi_i\rangle\rvert^2. When using position pointers, regardless of whether one measures a transverse or longitudinal phase shift, the signal of interest is amplified by the factor AwA_w, at the cost of a reduced probability PwP_w.

In principle, directly measuring the amplified position shift gAwgA_w can estimate the coupling strength gg. Meanwhile, the weak interaction inevitably changes the pointer state and slightly alters the postselected state, thereby leading to a probability change ΔPw\Delta P_w of successful postselection. Therefore, two approaches for estimating gg can be used see Fig. 1(c): measuring the position shift and measuring the probability change ΔPw\Delta P_w of successful postselection. Previous experiments show that direct measurement of the pointer shift in free space using a CCD can approach the shot-noise limit [18, 23, 25]. Measuring the optical output power, i.e., the probability change ΔPw\Delta P_w, offers distinct advantages when the WVA protocol is employed in a difference/balanced detection scheme [26, 27, 28, 29] and in fiber-based systems [28, 30, 31]. Additionally, the lock-in amplifier, which can encode the shift into its output phase, suppresses low-frequency noise caused by environmental disturbances, enabling nearly-static signal measurements that vary slowly [11, 32]. Therefore, one should carefully choose the estimator for WVA in the presence of real environmental noise.

Here, we systematically evaluate five estimators for WVA using a position pointer to a few-attosecond time delay: CCD-detected fringe shift Δx\Delta x, quadrant photodiode (PDQ) transversal voltage difference (XDIFF), and lock-in amplifier output phase η\eta (for Δx\Delta x measurement), as well as PDQ total output voltage (SUM) and CCD-detected average photon number NrN_r (for ΔPw\Delta P_w measurement). Our results suggest that the direct CCD-detected fringe shift Δx\Delta x and the lock-in output serve as the optimal estimators for low-power (0.5 mW) and high-power (50 mW) laser inputs, respectively.

As shown in Figure 1, we display the experimental setup for weak value amplification measuring the birefringent time delay τ\tau with various estimators. The basic experiment follows previous work [18] measuring τ\tau with real weak values using two different postselections inside a double-slit interferometer, which converts the longitudinal time delay τ\tau along the zz-axis into a transverse position shift along the xx-axis. A TEM00 mode beam passes through a polarizing beam splitter (PBS) and a half-wave plate (HWP) for preselection, preparing the photon in the state ∣Ψi⟩=sin⁡(45∘)∣H⟩+cos⁡(45∘)∣V⟩|\Psi_i\rangle=\sin(45^\circ)|H\rangle+\cos(45^\circ)|V\rangle. The light then passes through two HWPs, which serve as the weak interaction process and introduce the birefringent time delay τ\tau. By tilting the second HWP by an angle θ\theta around the xx-axis, the optical path length through it increases. This introduces a delay between the xx and yy polarizations given by [17, 18]: τ≈πθ22n02ω\tau\approx\frac{\pi\theta^2}{2n_0^2\omega}, where n0=1.54n_0=1.54 is the refractive index of the HWPs. The two postselections are implemented by a double-slit interferometer consisting of two HWPs at different postselection angles βl\beta^l and βr\beta^r followed by a PBS. They project onto the states:

Figure 1. Study of measuring the time delay using WVA with various estimators. (a) Experimental setup. The WVA protocol consists of preselection, weak interaction, postselection, and readout. The setup consists of a narrow-linewidth Coherent OBIS 633 nm laser with a beam diameter of 0.5 mm; two polarizing beam splitters (PBS1 and PBS2); four mirrors (M1–M4); five true zero-order half-wave plates (HWP1–HWP5); an electro-optic modulator (EOM); four lenses (L1–L4) with focal lengths of 25.5, 300, 300, and 25.5 mm, respectively; a double-slit assembly with a slit width of 50 μm\mu\mathrm{m} and a slit separation of 5 mm; a quadrant photodiode (PDQ); and a data acquisition system (DAQ). (b) Fast-axis orientations of the HWPs with respect to the laboratory yy-axis. The time delay τ\tau is introduced by rotating HWP3 around the xx-axis by an angle θ\theta. Because the slits are oriented along the xx-axis, the time-delay-dependent fringe shift is measured along xx, whereas the refraction-induced beam displacement occurs primarily along yy and is therefore separated from the measured signal. (c) The time delay τ\tau can be estimated from either the pointer shift Δx\Delta x or the probability change ΔPw\Delta P_w. Here, the two-slit diffraction interference converts the longitudinal temporal shift δtl,r=Re⁡[Awl,r]τ\delta t^{l,r}=\operatorname{Re}[A_w^{l,r}]\tau induced by single WVA into a transverse fringe displacement, enabling the time delay to be measured through the spatial interference pattern. Five estimators are considered: the PDQ output voltage (SUM), the transverse voltage difference from the PDQ (XDIFF), the fringe shift measured by the CCD (Δx\Delta x), the photon number measured by the CCD (NrN_r), and the output phase of the lock-in amplifier (η\eta). (d) Top view of the experiment.

∣Ψfl,r⟩=e−iωτ/2sin⁡(3π/4+βl,r)∣H⟩+e+iωτ/2cos⁡(3π/4+βl,r)∣V⟩,(1)|\Psi_f^{l,r}\rangle=e^{-i\omega\tau/2}\sin(3\pi/4+\beta^{l,r})|H\rangle+e^{+i\omega\tau/2}\cos(3\pi/4+\beta^{l,r})|V\rangle, \tag*{(1)}

The two postselections produce amplified temporal shifts δtl,r=Re⁡[Awl,r]τ\delta t^{l,r}=\operatorname{Re}[A_w^{l,r}]\tau. In this work, βl\beta^l and βr\beta^r are set to βl=1∘\beta^l=1^\circ and βr=−1∘\beta^r=-1^\circ, respectively, with opposite signs, enabling the maximum relative temporal shift ∣δtl−δtr∣|\delta t^l-\delta t^r| for a given magnitude of β\beta. As shown in Figure 1(c), diffraction interference converts the amplified time delay along the zz-axis into a transverse position shift along the xx-axis [18]. The resulting interference field is

⟨x,y∣Φf⟩=Eu∣Awr∣UueiωRe⁡[Awr]τ+El∣Awl∣UleiωRe⁡[Awl]τ,(2)\langle x,y|\Phi_f\rangle=\frac{E^u}{|A_w^r|}U^u e^{i\omega\operatorname{Re}[A_w^r]\tau}+\frac{E^l}{|A_w^l|}U^l e^{i\omega\operatorname{Re}[A_w^l]\tau}, \tag*{(2)}

where Ul,r(x,y)U^{l,r}(x,y) are complex diffraction amplitudes and El,rE_{l,r} remain constant using continuous-wave (CW) laser. A scientific CCD or quadrant position detector (PDQ) measures the position shift Δx\Delta x and the total probability change ΔPw=∣⟨Ψl∣Ψi⟩∣2+∣⟨Ψr∣Ψi⟩∣2\Delta P_w = |\langle\Psi_l|\Psi_i\rangle|^2 + |\langle\Psi_r|\Psi_i\rangle|^2. A scientific CCD or quadrant position detector (PDQ) measures the position shift Δx\Delta x and the total probability change ΔPw=∣⟨Ψl∣Ψi⟩∣2+∣⟨Ψr∣Ψi⟩∣2\Delta P_w = |\langle\Psi_l|\Psi_i\rangle|^2 + |\langle\Psi_r|\Psi_i\rangle|^2.

For readout, five estimators are investigated as follows (see Sec. I in SM for details): (i) Δx\Delta x: the interference fringes are detected by a CCD with an effective pixel size of 456 × 98, and the fringe shift Δx\Delta x is obtained using an image registration algorithm [33]. (ii) XDIFF: a PDQ with a K-Cube position sensing detector (PSD) auto aligner (Thorlabs, KPA101) measures the position shift by indirectly measuring a left-minus-right difference (XDIFF) signal. Here, the XDIFF signal is comparable to a difference/balanced detection scheme [26, 27, 28, 29]. (iii) Lock-in output η\eta: an electro-optic phase modulator (EOM) is used to modulate the preselection state with an additional sinusoidal phase 0.23×sin⁡(2π×50 kHz×t)0.23 \times\sin(2\pi\times50\ \mathrm{kHz} \times t) rad, inducing a fringe shift oscillating at 50 kHz. (iv) SUM: the PDQ with a PSD auto aligner also outputs the total received photon power, which monitors the probability change ΔPw\Delta P_w of successful postselection. (v) NrN_r: the average photon number detected by the CCD is calculated and used to measure the probability change ΔPw\Delta P_w.

For all estimators, the time delay τ\tau is controlled by periodically rotating the angle θ\theta, which is varied slowly at a frequency of 0.5 Hz according to θ=0∘,2∘,4∘,6∘,8∘,10∘,12∘,14∘,12∘,10∘,8∘,6∘,4∘,2∘\theta= 0^\circ, 2^\circ, 4^\circ, 6^\circ, 8^\circ, 10^\circ, 12^\circ, 14^\circ, 12^\circ, 10^\circ, 8^\circ, 6^\circ, 4^\circ, 2^\circ. As shown in Figure 1(c), this modulation produces a slowly varying fringe shift, from which τ\tau is estimated using the responses of the different estimators. Figure 2 shows the responses of the five estimators to the time-varying delay τ\tau at different input powers. For each estimator, ten independent calibration measurements were performed, and the resulting response was linearly fitted to determine the sensitivity k=∂O/∂τk = \partial O/\partial\tau, where O=ΔxO = \Delta x, XDIFF, η\eta, SUM, or NrN_r. The mean and standard deviation of the ten fitted values of kk were used to quantify the estimator uncertainty at τ=0\tau= 0 according to

Figure 2. Responses of the five estimators. (a)–(c) Lock-in amplifier output phase η\eta at input powers P0=0.5P_0 = 0.5 mW, 5 mW, and 50 mW, respectively; (d)–(f) PDQ transverse voltage difference XDIFF at P0=0.5P_0 = 0.5 mW, 5 mW, and 50 mW, respectively; (g)–(i) PDQ total output voltage SUM at P0=0.5P_0 = 0.5 mW, 5 mW, and 50 mW, respectively; (j) and (k) CCD-detected average photon number and fringe shift Δx\Delta x, respectively, at P0=0.5P_0 = 0.5 mW; (l) Normalized PDQ transverse voltage difference XDIFF/SUM. See the linear fit between the estimator and the set time delay in the Supplemental Material.

στ(T)=σO(T)k.(3)\sigma_{\tau}(T) = \frac{\sigma_{O}(T)}{k}. \tag*{(3)}
DetectorEstimatorP0=0.5 mWP_0=0.5\ \mathrm{mW}P0=5 mWP_0=5\ \mathrm{mW}P0=50 mWP_0=50\ \mathrm{mW}Constraints
P0∗=0.066 mWP_0^*=0.066\ \mathrm{mW}P0∗=0.71 mWP_0^*=0.71\ \mathrm{mW}P0∗=7.1 mWP_0^*=7.1\ \mathrm{mW}
CCDΔx\Delta x(5.30±0.10)×10−3(5.30 \pm0.10) \times10^{-3} ✓––Detector saturation
CCDNrN_r(1.46±0.07)×10−1(1.46 \pm0.07) \times10^{-1}––Power fluctuations
CCDCRB3.48×10−33.48 \times10^{-3}–––
PDQη\eta(4.39±0.81)×10−1(4.39 \pm0.81) \times10^{-1}(9.90±0.11)×10−2(9.90 \pm0.11) \times10^{-2}(1.80±0.06)×10−3(1.80 \pm0.06) \times10^{-3} ✓Bandwidth limited
PDQSUM(5.67±38.63)×100(5.67 \pm38.63) \times10^{0}(8.61±1.45)×10−2(8.61 \pm1.45) \times10^{-2}(1.96±0.18)×10−1(1.96 \pm0.18) \times10^{-1}Power fluctuations
PDQXDIFF(4.81±14.19)×10−1(4.81 \pm14.19) \times10^{-1}(1.42±0.23)×10−1(1.42 \pm0.23) \times10^{-1}(3.24±0.10)×10−2(3.24 \pm0.10) \times10^{-2}Power fluctuations
PDQCRB1.44×10−21.44 \times10^{-2}4.37×10−34.37 \times10^{-3}1.38×10−31.38 \times10^{-3}–

Table 1. Minimum Allan deviations (in as) of the measured time-delay estimators, including the uncertainty contribution from the calibration coefficients. The precision of each estimator is compared with the corresponding CRB and the relevant experimental constraints. The check marks (✓) indicate the experimentally optimal estimator in each operating regime: CCD Δx\Delta x at P0=0.5 mWP_0=0.5\ \mathrm{mW} (laser-power-limited regime) and PDQ lock-in phase η\eta at P0=50 mWP_0=50\ \mathrm{mW} (detector-limited regime).

Detailed calibration procedures and uncertainty analyses are provided in the SM.

It can be seen from Figure 2(d) and (Figure 2g) that, at low laser power, the XDIFF and SUM estimators exhibit little to no measurable response to the time delay τ\tau, with their fitted sensitivities kk approaching zero (see SM). This result highlights the advantage of the CCD-based estimators under low-power conditions. As the optical power increases, all estimators exhibit progressively stronger responses to τ\tau, with increasingly clear periodic variations.

Figure 3 displays the measured Allan deviation στ(T)\sigma_\tau(T) of the five estimators. At P0=0.5 mWP_0=0.5\ \mathrm{mW}, directly measuring the fringe shift with a CCD yields the highest precision, consistent with other shot-noise-limited experiments using CCD detectors [18, 23, 25]. This advantage arises because the Δx\Delta x estimator is not disturbed by laser fluctuations. However, this estimator is limited by detector saturation. At P0=50 mWP_0=50\ \mathrm{mW}, measuring the pointer shift with the lock-in amplifier achieves a lower Allan deviation at longer averaging times. In the lock-in amplifier setup, the time constant is set to 1 s (time delays varying faster than 1 Hz will be measured with reduced sensitivity), so the Allan curve is plotted only for averaging times longer than 1 s. Thus, the lock-in output η\eta is ultimately limited by the finite detection bandwidth.

Allan deviation curves for measuring the birefringence time delay

Figure 3. The Allan deviation στ(T)\sigma_\tau(T) for measuring the birefringence time delay at τ=0\tau=0. The CCD results are obtained when the CCD pixels are saturated at a laser power of 0.5 mW and an exposure time of 100 μ\mus.

Although normalization of XDIFF by SUM (XDIFF/SUM) is theoretically expected to improve precision, Figure 2(l) shows that it performs worse than both XDIFF and SUM, mainly due to the reduced photon power after WVA postselection. Nevertheless, at 50 mW with lock-in detection, the η\eta estimator achieves superior long-term stability, making it attractive for practical applications with high-power optical sources.

To establish the photon-statistical sensitivity limit, we calculate the Cramér–Rao bound (CRB) for ideal coherent state under shot-noise-limited detection [34]. At λ=633 nm\lambda=633\ \mathrm{nm}, the detected photon rate is R=ηP0∗/hc/λR=\eta P_0^*/hc/\lambda, where P0∗P_0^* denotes the optical power measured between L4 and PBS2 [see Figure 1(a)], prior to WVA postselection and therefore independent of the postselection setting. We use ηPDQ=0.784\eta_{\mathrm{PDQ}}=0.784 at 633 nm for the Thorlabs PDQ80A and ηCCD≈0.45\eta_{\mathrm{CCD}}\approx0.45 for the Sony IMX264 sensor [35]. The delay-estimation CRB is

δτCRB=1ω0N=λ2πc2BhcηP0∗λ(4)\delta\tau_{\mathrm{CRB}}=\frac{1}{\omega_0\sqrt{N}}=\frac{\lambda}{2\pi c}\sqrt{\frac{2Bh c}{\eta P_0^*\lambda}} \tag*{(4)}

with N=RTN=RT, T=1/2BT=1/2B, where ω0=2πc/λ\omega_0=2\pi c/\lambda. For the PDQ measurements with B=150 kHzB=150\ \mathrm{kHz} and the CCD measurements, using T=100 μsT=100\ \mu\mathrm{s} and P0∗=0.065 mWP_0^*=0.065\ \mathrm{mW}, respectively, the corresponding shot-noise-limited delay uncertainties are calculated and presented in Table I. These values define the ideal photon-statistical limits for comparison with the measured delay precision.

In Table I, we compare the precision of the five estimators and highlight two experimentally relevant operating regimes. At P0=0.5P_0 = 0.5 mW, corresponding to a laser-power-limited regime, the estimator Δx\Delta x achieves the smallest measured Allan deviation and approaches the CRB. In contrast, at P0=50P_0 = 50 mW, corresponding to a detector-limited regime, the PDQ combined with lock-in detection provides superior time delay precision. It also yields a lower minimum detectable delay than the estimator Δx\Delta x while remaining close to the CRB. These results show that the optimal readout depends on the available optical power and detector dynamic range: direct spatial readout is effective in the low-power regime, whereas photodiode detection with lock-in demodulation becomes advantageous when higher optical power is available.

Finally, our results suggest the possibility of an optimal estimator in the proposed WVA protocol. Such a protocol could be implemented by measuring the position shift using a high-well-depth, high-speed CCD detector in combination with a lock-in amplifier. The large full-well capacity enables the collection of more photons per frame, thereby reducing shot-noise variance through improved photon statistics. Meanwhile, the high frame rate provides sufficiently fast acquisition to fit lock-in detection, allowing measurements to be shifted away from the low-frequency regime where 1/f1/f noise dominates.

In summary, we systematically evaluate five estimators for WVA-based measurements of attosecond-scale time delays. Our results provide practical guidance for selecting the readout method according to the available optical power, detector limitations, and noise conditions.

**Acknowledgments—**This study was supported by the NSFC (Grants No. U25D8008, No. 42504048 and No. 42327803), Hubei Provincial NSFC (Grant No. 20250650025), the Fellowship Program of China National Postdoctoral Program for Innovative Talents under Grant Number BX20250161. The data supporting this work are publicly available online [36].

Mathematical extraction of the pointer observables

The pointer response to the time delay τ\tau is quantified using five experimentally accessible estimators: the CCD fringe displacement Δx\Delta x, the PDQ differential signal XDIFF, the lock-in output phase η\eta, the PDQ total signal SUM, and the CCD-derived average photon number NrN_r. Although these estimators probe different aspects of the postselected optical field, each provides an observable whose response to τ\tau can be calibrated experimentally. The five readout methods differ in how the observable/signal is extracted from the experimental data, as described below.

CCD fringe displacement Δx\Delta x

The interference pattern is recorded using a CCD camera, and the effective image region used for analysis contains 456×98456 \times98 pixels. Let Iτ(x,y)I_{\tau}(x,y) denote the recorded fringe image at time delay τ\tau, and let Iref(x,y)I_{\mathrm{ref}}(x,y) denote the reference image. The relative fringe displacement is extracted using an image-registration algorithm [33]. The horizontal displacement is determined by identifying the translation that best aligns the measured fringe image with the reference image:

Δx=arg min⁡δx C(δx),(5)\Delta x = \underset{\delta x}{\operatorname{arg\,min}}\ C(\delta x), \tag*{(5)}

where C(δx)C(\delta x) is the image-registration cost function evaluated for a horizontal translation δx\delta x. The extracted displacement Δx\Delta x is then used as the pointer observable. This method directly measures the spatial displacement of the interference fringes rather than inferring it from the total detected optical power.

PDQ differential signal XDIFF

The quadrant photodiode (PDQ), equipped with a K-Cube position-sensing detector (PSD) auto-aligner (Thorlabs, KPA101), generates electrical signals corresponding to the optical power incident on its detector segments. The XDIFF observable is obtained from the left-minus-right differential signal,

XDIFF=VL−VR,(6)\mathrm{XDIFF} = V_{\mathrm{L}} - V_{\mathrm{R}}, \tag*{(6)}

where VLV_{\mathrm{L}} and VRV_{\mathrm{R}} denote the corresponding left- and right-side detector outputs. A displacement of the interference pattern redistributes the detected optical power between the two sides, thereby changing XDIFF. The time delay is inferred from the calibrated response of this differential signal to τ\tau. This readout is analogous to differential or balanced detection schemes used in optical measurements [26, 27, 28, 29].

Lock-in output phase η\eta

For phase-sensitive readout, an electro-optic modulator (EOM) applies a sinusoidal phase modulation to the preselection state,

ϕmod(t)=0.23sin⁡(2πfmt) rad,fm=50 kHz.(7)\phi_{\mathrm{mod}}(t) = 0.23 \sin(2\pi f_{\mathrm{m}}t)\ \mathrm{rad}, \qquad f_{\mathrm{m}} = 50\ \mathrm{kHz}. \tag*{(7)}

Rotating HWP3 introduces a controllable time delay τ\tau, which modifies the phase of the detected signal at the modulation frequency. The lock-in amplifier demodulates this signal using a reference synchronized with the EOM modulation. For a detected signal of the form

Vs(t)=V0+Acos⁡(2πfmt+ητ),(8)V_{\mathrm{s}}(t) = V_0 + A\cos(2\pi f_{\mathrm{m}}t+\eta_{\tau}), \tag*{(8)}

the in-phase and quadrature components are obtained by multiplying the detected signal Vs(t)V_{\mathrm{s}}(t) by the corresponding reference signal Vr(t)=V0+Acos⁡(2πfmt)V_{\mathrm{r}}(t)=V_0+A\cos(2\pi f_{\mathrm{m}}t) and then applying low-pass filtering:

X=LPF⁡[2V(t)cos⁡(2πfmt)]=Acos⁡η,Y=LPF⁡[−2V(t)sin⁡(2πfmt)]=Asin⁡η,(9)X = \operatorname{LPF}[2V(t)\cos(2\pi f_{\mathrm{m}}t)] = A\cos\eta,\qquad Y = \operatorname{LPF}[-2V(t)\sin(2\pi f_{\mathrm{m}}t)] = A\sin\eta, \tag*{(9)}

where LPF⁡[⋅]\operatorname{LPF}[\cdot] denotes low-pass filtering. The lock-in output phase is then calculated as

η=arctan⁡(Y,X).(10)\eta= \arctan(Y,X). \tag*{(10)}

Within the calibrated operating range, the output phase varies approximately linearly with the applied time delay,

η(τ)≃η0+kητ,τ^=η−η0kη,(11)\eta(\tau) \simeq\eta_0 + k_\eta\tau,\qquad\hat{\tau} = \frac{\eta-\eta_0}{k_\eta}, \tag*{(11)}

where η0\eta_0 is the reference phase at zero time delay and kη=∂η/∂τk_\eta= \partial\eta/\partial\tau is the calibrated sensitivity.

PDQ total signal SUM

In addition to the differential output, the PDQ provides a total-power signal, denoted by SUM. It is obtained from the sum of the detector outputs,

SUM=∑jVj,(12)\mathrm{SUM} = \sum_j V_j, \tag*{(12)}

where VjV_j denotes the output associated with detector segment jj. The SUM signal tracks changes in the total detected optical power and therefore provides an indirect measure of changes in the postselection probability. The response of SUM to the controlled time delay is calibrated experimentally, and the time delay is estimated using the corresponding sensitivity kSUMk_{\mathrm{SUM}}.

CCD-derived average photon number NrN_r

The CCD images also provide a measure of the total detected signal within the selected region of interest. Let CpC_p denote the recorded signal associated with pixel pp, after the prescribed background and offset corrections. The integrated CCD signal for a given frame is

SCCD=∑p∈ROICp.(13)S_{\mathrm{CCD}} = \sum_{p\in\mathrm{ROI}} C_p. \tag*{(13)}

Here, the region of interest (ROI) is the selected portion of the CCD image used for image registration and signal extraction. The average detected signal over MM frames is then

S‾CCD=1M∑m=1MSCCD(m).(14)\overline{S}_{\mathrm{CCD}} = \frac{1}{M}\sum_{m=1}^{M} S_{\mathrm{CCD}}^{(m)}. \tag*{(14)}

When converted using the applicable camera calibration, this integrated signal provides an estimate of the average detected photon number NrN_r. Because the total detected signal depends on the postselection probability, changes in NrN_r provide an indirect measure of the time-delay-dependent probability variation. The time delay is estimated from the calibrated response of NrN_r to τ\tau.

Detailed calibration and uncertainty analysis of the time-delay estimators

This section describes the calibration procedures and uncertainty analysis for all five time-delay estimators. Each experimentally measured observable, O\mathcal{O}, is calibrated against the controlled time delay τ\tau using a linear model:

O(τ)=O0+kτ,(15)\mathcal{O}(\tau) = \mathcal{O}_0 + k\tau, \tag*{(15)}

where O=Δx\mathcal{O} = \Delta x, XDIFF, η\eta, SUM, or NrN_r. Here, O0\mathcal{O}_0 is the fitted intercept and

k=∂O∂τ(16)k = \frac{\partial\mathcal{O}}{\partial\tau} \tag*{(16)}

is the calibration coefficient.

For each estimator, ten independent data sets were acquired, and an individual linear fit was performed for each data set. The mean calibration coefficient was calculated as

kˉ=1M∑i=1Mki,(17)\bar{k} = \frac{1}{M}\sum_{i=1}^{M} k_i, \tag*{(17)}

where MM denotes the number of independent measurements, with M=10M = 10.

The sample standard deviation of the fitted calibration coefficients was calculated as

σk=1M−1∑i=1M(ki−kˉ)2.(18)\sigma_k = \sqrt{\frac{1}{M-1}\sum_{i=1}^{M}(k_i-\bar{k})^2}. \tag*{(18)}

Here, σk\sigma_k characterizes the reproducibility of the calibration coefficient among the ten independent measurements. The time delay was controlled by changing the tilting angle θ\theta of HWP3. For λ=633\lambda= 633 nm, refractive index n0=1.545n_0 = 1.545, and c=3×108c = 3 \times10^8 m/s, the corresponding time delay was calculated from

τ=πω[11−sin⁡2θ/n02−1].(19)\tau= \frac{\pi}{\omega}\left[\frac{1}{\sqrt{1-\sin^2\theta/n_0^2}}-1\right]. \tag*{(19)}

For small θ\theta, this expression can be approximated by

τ≈πθ22n02ω.(20)\tau\approx\frac{\pi\theta^2}{2n_0^2\omega}. \tag*{(20)}

The resulting delay was expressed in attoseconds (as). Six delay values were used for each calibration data set, corresponding to

θ=2∘,4∘,6∘,8∘,10∘,12∘.(21)\theta= 2^\circ, 4^\circ, 6^\circ, 8^\circ, 10^\circ, 12^\circ. \tag*{(21)}

Once the calibration coefficient has been determined, the estimated time delay is given by

τ^=O−O0k.(22)\hat{\tau} = \frac{\mathcal{O}-\mathcal{O}_0}{k}. \tag*{(22)}

The Allan deviation of the corresponding time-delay sequence is therefore

στ(T)=σO(T)∣k∣,(23)\sigma_\tau(T) = \frac{\sigma_{\mathcal{O}}(T)}{\lvert k\rvert}, \tag*{(23)}

where σO(T)\sigma_O(T) is the Allan deviation of the measured observable at averaging time TT. The uncertainty associated with the calibration coefficient is propagated according to

uτ,k=∣∂στ∂k∣uk.(24)u_{\tau,k} = \left|\frac{\partial\sigma_\tau}{\partial k}\right|u_k. \tag*{(24)}

Using στ=σO/∣k∣\sigma_\tau= \sigma_O/|k|, this contribution can also be written as

uτ,k=σOk2uk.(25)u_{\tau,k} = \frac{\sigma_O}{k^2}u_k. \tag*{(25)}

The corresponding relative uncertainty is

uτ,kστ=uk∣k∣.(26)\frac{u_{\tau,k}}{\sigma_\tau} = \frac{u_k}{|k|}. \tag*{(26)}

In the following sections, uku_k is taken as the sample standard deviation of the ten independently fitted calibration coefficients.

CCD calibration with Δx\Delta x and CCD-detected photon number NrN_r at 0.5 mW

When the HWP angle θ\theta is periodically varied, the interference fringe shifts accordingly, providing a direct response to the controlled time delay. Figure 4 shows a representative time window of the raw interference fringes recorded by the CCD during the periodic variation of θ=0∘,2∘,4∘,6∘,8∘,10∘,12∘,14∘,12∘,10∘,8∘,6∘,4∘,2∘\theta= 0^\circ, 2^\circ, 4^\circ, 6^\circ, 8^\circ, 10^\circ, 12^\circ, 14^\circ, 12^\circ, 10^\circ, 8^\circ, 6^\circ, 4^\circ, 2^\circ. The fringe position exhibits a clear temporal response to the applied time delay.

Figure 4. Representative raw interference fringes recorded by the CCD as the HWP angle θ\theta was varied periodically. The fringe position shifts along the xx axis in response to the controlled time delay τ\tau. The image is stretched along the xx direction to make the fringe displacement easier to observe.

At an input laser power of P0=0.5P_0 = 0.5 mW, two CCD-based estimators were investigated. The first is the fringe displacement Δx\Delta x, obtained using an image-registration algorithm based on upsampled cross-correlation [33]. The effective CCD area used in the analysis contains 456×98456 \times98 pixels. The second estimator is the average CCD-detected photon number NrN_r, which characterizes the probability change associated with successful postselection.

As shown in Figure 5, ten independent linear fits were performed for each estimator using data from the linear region within each half-period. The individual fitting coefficients and their statistical parameters are summarized in Table II.

Figure 5. Estimation of the time delay using the CCD detector at an input optical power of P0=0.5P_0 = 0.5 mW. (a) Linear fits between the CCD-detected average photon number NrN_r and the calibrated time delay τ\tau for ten independent measurements. (b) Linear fits between the CCD-detected fringe displacement Δx\Delta x and the calibrated time delay τ\tau for the same ten measurements. (c) Time-delay fluctuations reconstructed from the corresponding CCD observables during the noise measurements.

FitkNrk_{N_r} (as−1^{-1})kΔxk_{\Delta x} (pixel/as)
16.7814×1036.7814 \times10^{3}1.434
26.3144×1036.3144 \times10^{3}1.416
36.3815×1036.3815 \times10^{3}1.441
46.2344×1036.2344 \times10^{3}1.418
56.1276×1036.1276 \times10^{3}1.409
66.2588×1036.2588 \times10^{3}1.429
76.4996×1036.4996 \times10^{3}1.409
86.3638×1036.3638 \times10^{3}1.361
95.9237×1035.9237 \times10^{3}1.411
105.5626×1035.5626 \times10^{3}1.369
Mean6.245×1036.245 \times10^{3}1.4097
SD3.288×1023.288 \times10^{2}2.60×10−22.60 \times10^{-2}

Table II. Individual linear-fitting slopes for the CCD-detected photon number NrN_r and fringe displacement Δx\Delta x at an input laser power of P0=0.5P_0 = 0.5 mW. Ten independent data sets were analyzed. The last two rows give the mean and sample standard deviation (SD) of the fitted slopes.

The resulting calibration coefficient and the corresponding relative calibration uncertainty for the fringe-displacement estimator are

kΔx=1.4097±0.0260 pixel/as,uk,ΔxkΔx=0.02601.4097=1.84%.(27)k_{\Delta x} = 1.4097 \pm0.0260\ \mathrm{pixel/as},\qquad\frac{u_{k,\Delta x}}{k_{\Delta x}} = \frac{0.0260}{1.4097} = 1.84\%. \tag*{(27)}

For the photon-number estimator, the corresponding calibration coefficient and relative calibration uncertainty are

kNr=(6.245±0.329)×103 as−1,uk,NrkNr=0.3296.245=5.27%.(28)k_{N_r} = (6.245 \pm0.329) \times10^{3}\ \mathrm{as}^{-1}, \qquad\frac{u_{k,N_r}}{k_{N_r}} = \frac{0.329}{6.245} = 5.27\%. \tag*{(28)}

To obtain the Allan deviation στ(T)\sigma_{\tau}(T) of the measured time delay, the rotation angle is set to θ=0∘\theta= 0^\circ, corresponding to zero time delay. The fluctuations of the CCD-detected fringe shift Δx\Delta x and the average photon number NrN_r are then recorded. Using the corresponding calibration sensitivities kk, the time-delay fluctuations are estimated as Δx/k\Delta x/k and Nr/kN_r/k, respectively, as shown in Figure 5(c). The Allan deviations of the two estimators are then calculated from these time-delay data, yielding the curves presented in the main text.

For the estimator Δx\Delta x, the minimum Allan deviation of the measured time-delay sequence was

στ,Δxmin⁡=5.3×10−3 as.(29)\sigma_{\tau,\Delta x}^{\min} = 5.3 \times10^{-3}\ \mathrm{as}. \tag*{(29)}

The corresponding contribution from the calibration uncertainty is

uτ,kΔx=στ,Δxmin⁡uk,ΔxkΔx=9.78×10−5 as.(30)u_{\tau,k}^{\Delta x} = \sigma_{\tau,\Delta x}^{\min}\frac{u_{k,\Delta x}}{k_{\Delta x}} = 9.78 \times10^{-5}\ \mathrm{as}. \tag*{(30)}

The resulting minimum time-delay resolution, including the calibration contribution, is therefore

στ,Δxmin⁡=(5.30±0.10)×10−3 as.(31)\sigma_{\tau,\Delta x}^{\min} = (5.30 \pm0.10) \times10^{-3}\ \mathrm{as}. \tag*{(31)}

For the photon-number estimator, the minimum Allan deviation was

στ,Nrmin⁡=1.46×10−1 as.(32)\sigma_{\tau,N_r}^{\min} = 1.46 \times10^{-1}\ \mathrm{as}. \tag*{(32)}

The corresponding calibration contribution is

uτ,kNr=στ,Nrmin⁡uk,NrkNr=7.69×10−3 as.(33)u_{\tau,k}^{N_r} = \sigma_{\tau,N_r}^{\min}\frac{u_{k,N_r}}{k_{N_r}} = 7.69 \times10^{-3}\ \mathrm{as}. \tag*{(33)}

The resulting minimum time-delay resolution, including the calibration contribution, is

στ,Nrmin⁡=(1.46±0.08)×10−1 as.(34)\sigma_{\tau,N_r}^{\min} = (1.46 \pm0.08) \times10^{-1}\ \mathrm{as}. \tag*{(34)}

The calibration uncertainties are obtained from the sample standard deviations of the ten independent calibration measurements. The minimum Allan deviations are determined from the Allan cure in Figure 3 of the main text and calibration-uncertainty contributions are summarized in Table III.

Estimatorkkστmin⁡\sigma_{\tau}^{\min}uτ,ku_{\tau,k}
Δx\Delta x(1.410±0.026)(1.410 \pm0.026) pixel/as5.30×10−35.30 \times10^{-3} as9.78×10−59.78 \times10^{-5} as
NrN_r(6.245±0.329)×103(6.245 \pm0.329) \times10^{3} as−1^{-1}1.46×10−11.46 \times10^{-1} as7.69×10−37.69 \times10^{-3} as

Table III. Minimum Allan deviation of the CCD-based time-delay estimators and the corresponding uncertainty contribution from the calibration coefficient at P0=0.5P_0 = 0.5 mW.

PDQ calibration with lock-in amplifier phase η\eta, SUM, and XDIFF at 0.5 mW

Unlike the CCD-based measurement, the estimators based on the lock-in amplifier output phase (η\eta), the PDQ transverse voltage difference (XDIFF), and the PDQ total output voltage (SUM) directly provide the response signal without further data processing. Therefore, the results obtained with the PDQ shown in Figure 2 of the main text represent the original measured data.

At an input laser power of 0.5 mW, three estimators were obtained from the PDQ detector: the lock-in amplifier output phase η\eta, the total received signal SUM, and the transversal position signal XDIFF.

Ten independent linear fits were performed for each estimator and were displayed in Figure 6. The individual slopes and their statistical parameters are summarized in Table IV.

Figure 6. Detailed calibration and time-delay estimation using the PDQ detector at an input laser power of 0.5 mW. (a) Linear fits between the lock-in amplifier output phase η\eta and the set time delay τ\tau; (b) linear fits between the PDQ total output voltage SUM and τ\tau; (c) linear fits between the PDQ transversal voltage difference XDIFF and τ\tau; (d) recorded laser input power; and (e) estimated time delay as a function of measurement time.

Fitkηk_{\eta} (deg/as)kSUMk_{\mathrm{SUM}} (mV/as)kXDIFFk_{\mathrm{XDIFF}} (mV/as)
10.4520.01000.0000
20.3240.01000.0000
30.3800.0010-0.0019
40.466-0.00400.0066
50.324-0.00400.0000
60.3170.0000-0.0014
70.2950.00300.0068
80.3610.00000.0000
90.433-0.00400.0000
100.281-0.00400.0003
Mean0.363300.000800.00104
SD0.066860.005450.00307

Table IV. Ten independent fitting slopes for the three PDQ estimators at P0=0.5P_0 = 0.5 mW. The last two rows give the mean and sample standard deviation (SD) of the fitted slopes.

The corresponding calibration coefficient for the lock-in phase is

kη0.5=0.36330±0.06686.(35)k_{\eta}^{0.5} = 0.36330 \pm0.06686. \tag*{(35)}

For the SUM estimator,

kSUM0.5=0.00080±0.00545.(36)k_{\mathrm{SUM}}^{0.5} = 0.00080 \pm0.00545. \tag*{(36)}

For the XDIFF estimator,

kXDIFF0.5=0.00104±0.00307.(37)k_{\mathrm{XDIFF}}^{0.5} = 0.00104 \pm0.00307. \tag*{(37)}

At an input optical power of 0.5 mW, the SUM and XDIFF estimators exhibit relatively weak calibration responses, with mean fitted slopes comparable to or smaller than their standard deviations across the ten independent measurements. We attribute this limited calibration performance primarily to the finite signal resolution of the photodiode quadrant detector (PDQ) and the analog-to-digital conversion resolution of the data acquisition (DAQ) system at low signal levels. Under these conditions, the SUM and XDIFF voltage variations are too small to be reliably resolved by the DAQ alone. In contrast, the lock-in amplifier, which incorporates a more advanced signal-processing system and noise-rejection techniques, can extract weak signals through phase-sensitive detection, enabling more reliable estimation of the output phase (η\eta) under the same low-power conditions.

Although these weak calibration responses lead to larger uncertainties in the corresponding time-delay estimates, all estimators are evaluated using the same calibration and uncertainty-analysis procedures, ensuring a consistent comparison of their practical performance. The results indicate that, at this low optical power, the phase-based estimator and the CCD-based estimators provide more reliable time-delay estimates than SUM and XDIFF. This comparison highlights the impact of detector and acquisition-system limitations and demonstrates the importance of selecting an appropriate readout observable for low-power measurements.

PDQ calibration with lock-in amplifier phase η\eta, SUM, and XDIFF at 5 mW

At an input laser power of 5 mW, the PDQ detector again provided three independent observables: the lock-in amplifier output phase η\eta, SUM, and XDIFF. The ten independent fitting coefficients are summarized in Table V. The resulting calibration coefficient for the lock-in phase is

Fitkηk_{\eta} (deg/as)kSUMk_{\mathrm{SUM}} (mV/as)kXDIFFk_{\mathrm{XDIFF}} (mV/as)
13.2210.0210.0163
23.3120.0260.0163
33.2770.0230.0208
43.2150.0310.0199
53.2550.0260.0243
63.2540.0210.0243
73.2230.0260.0208
83.3000.0280.0263
93.3050.0280.0243
103.2770.0170.0199
Mean3.263900.024700.02132
SD0.036100.004160.00344

Table V. Ten independent fitting slopes for the three PDQ estimators at P0=5P_0 = 5 mW. The last two rows give the mean and sample standard deviation (SD) of the fitted slopes.

Figure 7. Detailed calibration and time-delay estimation using the PDQ detector at an input laser power of 5 mW. (a) Linear fits between the lock-in amplifier output phase η\eta and the set time delay τ\tau; (b) linear fits between the PDQ total output voltage SUM and τ\tau; (c) linear fits between the PDQ transversal voltage difference XDIFF and τ\tau; (d) recorded laser input power; and (e) estimated time delay as a function of measurement time.

kη5=3.26390±0.03610.(38)k_{\eta}^{5} = 3.26390 \pm0.03610. \tag*{(38)}

For the SUM estimator,

kSUM5=0.02470±0.00416.(39)k_{\mathrm{SUM}}^{5} = 0.02470 \pm0.00416. \tag*{(39)}

For the XDIFF estimator,

kXDIFF5=0.02132±0.00344.(40)k_{\mathrm{XDIFF}}^{5} = 0.02132 \pm0.00344. \tag*{(40)}

Unlike the 0.5 mW case, both the SUM and XDIFF estimators exhibit measurable responses at 5 mW. The calibration coefficients therefore provide direct conversion factors for the corresponding detector fluctuations into equivalent time-delay fluctuations.

PDQ calibration with lock-in amplifier phase η\eta, SUM, and XDIFF at 50 mW

At an input laser power of 50 mW, the three PDQ estimators show clear and reproducible responses to the controlled time delay. The ten individual fitting coefficients are summarized in Table VI. The corresponding calibration coefficient for the lock-in phase is

Fitkηk_{\eta} (deg/as)kSUMk_{\mathrm{SUM}} (mV/as)kXDIFFk_{\mathrm{XDIFF}} (mV/as)
117.1380.1030.2331
217.1140.0860.2287
316.9960.0940.2252
418.0890.0830.2387
517.4320.0810.2268
618.0380.0920.2331
718.0960.0830.2398
818.4690.1010.2235
917.3560.0920.2333
1018.5500.1030.2453
Mean17.72780.091800.23275
SD0.58440.008470.00697

Table VI. Ten independent fitting slopes for the three PDQ estimators at P0=50P_0 = 50 mW. The last two rows give the mean and sample standard deviation (SD) of the fitted slopes.

Figure 8. Detailed calibration and time-delay estimation using the PDQ detector at an input laser power of 50 mW. (a) Linear fits between the lock-in amplifier output phase η\eta and the set time delay τ\tau; (b) linear fits between the PDQ total output voltage SUM and τ\tau; (c) linear fits between the PDQ transversal voltage difference XDIFF and τ\tau; (d) recorded laser input power; and (e) estimated time delay as a function of measurement time.

kη50=17.7278±0.5844.(41)k_{\eta}^{50} = 17.7278 \pm0.5844. \tag*{(41)}

For the SUM estimator,

kSUM50=0.09180±0.00847.(42)k_{\mathrm{SUM}}^{50} = 0.09180 \pm0.00847. \tag*{(42)}

For the XDIFF estimator,

kXDIFF50=0.23275±0.00697.(43)k_{\mathrm{XDIFF}}^{50} = 0.23275 \pm0.00697. \tag*{(43)}

All three estimators exhibit a clear response at 50 mW. In particular, the XDIFF calibration coefficient increases substantially compared with its value at 5 mW, while the lock-in phase remains a strongly responsive phase-based estimator. These calibration coefficients are used to convert the corresponding detector fluctuations into equivalent time-delay fluctuations in the following analysis.

Minimum time-delay estimation and uncertainty of the PDQ estimators

The calibrated coefficients obtained above were used to convert the measured fluctuations of the three PDQ observables into equivalent time-delay fluctuations. For each estimator, the minimum Allan deviation of the reconstructed time-delay sequence was taken as the minimum time-delay estimation uncertainty from the Allan curve in Figure 3 of the main text, στmin⁡\sigma_{\tau}^{\min}. Following the procedure used for the CCD estimators, the contribution from the calibration-coefficient reproducibility was evaluated according to

uτ,k=στmin⁡σk∣k∣.(44)u_{\tau,k}=\sigma_{\tau}^{\min}\frac{\sigma_k}{\lvert k\rvert}. \tag*{(44)}

Here, kk and σk\sigma_k are the mean calibration coefficient and its sample standard deviation obtained from ten independent linear fits.

At P0=0.5P_0 = 0.5 mW, the minimum time-delay uncertainties obtained from the lock-in phase η\eta, SUM, and XDIFF estimators are

στ,ηmin⁡=(0.4391±0.0808) as,(45)\sigma_{\tau,\eta}^{\min}=(0.4391\pm0.0808)\ \mathrm{as}, \tag*{(45)}
στ,SUMmin⁡=(5.67±38.63) as,(46)\sigma_{\tau,\mathrm{SUM}}^{\min}=(5.67\pm38.63)\ \mathrm{as}, \tag*{(46)}
στ,XDIFFmin⁡=(0.481±1.419) as.(47)\sigma_{\tau,\mathrm{XDIFF}}^{\min}=(0.481\pm1.419)\ \mathrm{as}. \tag*{(47)}

At P0=5P_0 = 5 mW, all three estimators exhibit measurable calibration responses. The corresponding minimum time-delay uncertainties are

στ,ηmin⁡=(0.0099±1.095×10−4) as,(48)\sigma_{\tau,\eta}^{\min}=(0.0099\pm1.095\times10^{-4})\ \mathrm{as}, \tag*{(48)}
στ,SUMmin⁡=(0.0861±0.0145) as,(49)\sigma_{\tau,\mathrm{SUM}}^{\min}=(0.0861\pm0.0145)\ \mathrm{as}, \tag*{(49)}
στ,XDIFFmin⁡=(0.1419±0.0229) as.(50)\sigma_{\tau,\mathrm{XDIFF}}^{\min}=(0.1419\pm0.0229)\ \mathrm{as}. \tag*{(50)}

At P0=50P_0 = 50 mW, the corresponding results are

στ,ηmin⁡=(0.0018±5.934×10−5) as,(51)\sigma_{\tau,\eta}^{\min}=(0.0018\pm5.934\times10^{-5})\ \mathrm{as}, \tag*{(51)}
στ,SUMmin⁡=(0.1964±0.0181) as,(52)\sigma_{\tau,\mathrm{SUM}}^{\min}=(0.1964\pm0.0181)\ \mathrm{as}, \tag*{(52)}
στ,XDIFFmin⁡=(0.0324±9.703×10−4) as.(53)\sigma_{\tau,\mathrm{XDIFF}}^{\min}=(0.0324\pm9.703\times10^{-4})\ \mathrm{as}. \tag*{(53)}

The complete results are summarized in Table VII. The minimum Allan deviation represents the experimentally achieved time-delay resolution, whereas uτ,ku_{\tau,k} quantifies the additional uncertainty arising from the reproducibility of the calibration coefficient.

P0P_{0}Estimatorστmin⁡\sigma_{\tau}^{\min} (as)uτ,ku_{\tau,k} (as)
0.5 mWη\eta0.43910.0808
0.5 mWSUM5.669038.63
0.5 mWXDIFF0.48091.419
5 mWη\eta0.00991.095×10−41.095 \times10^{-4}
5 mWSUM0.08610.0145
5 mWXDIFF0.14190.0229
50 mWη\eta0.00185.934×10−55.934 \times10^{-5}
50 mWSUM0.19640.0181
50 mWXDIFF0.03249.703×10−49.703 \times10^{-4}

Table VII. Minimum Allan deviation of the PDQ-based time-delay estimators and the corresponding uncertainty contribution from the calibration coefficient.

Derivation and validity of the quadratic approximation for the time delay

The optical path difference (OPD)/time dealy between the two orthogonal polarization components is introduced using two true zero-order half-wave plates (HWPs) whose optical axes are oriented perpendicular to each other. Tilting the second HWP by an angle θ\theta about the xx-axis generates a polarization-dependent OPD δl\delta l. The geometrical effect of refraction at the air–HWP interface is accounted for through Snell’s law,

sin⁡r=sin⁡θn0,(54)\sin r = \frac{\sin\theta}{n_0}, \tag*{(54)}

where rr is the propagation angle inside the HWP and n0=1.54n_0 = 1.54 is the refractive index of the plate. Within the geometrical model used here, the resulting OPD is

δl=λ2(11−sin⁡2θ/n02−1),(55)\delta l = \frac{\lambda}{2}\left(\frac{1}{\sqrt{1-\sin^2\theta/n_0^2}}-1\right), \tag*{(55)}

where λ=632.992\lambda= 632.992 nm is the vacuum wavelength of the incident light.

For small tilting angles, using sin⁡θ≈θ\sin\theta\approx\theta and (1−x)−1/2≈1+x/2(1-x)^{-1/2} \approx1+x/2, with θ\theta expressed in radians, Eq. (55) reduces to

δl≈λθ24n02.(56)\delta l \approx\frac{\lambda\theta^2}{4n_0^2}. \tag*{(56)}

The corresponding time delay is obtained from τ=δl/c\tau= \delta l/c, where cc is the speed of light in vacuum. Using the angular frequency ω=2πc/λ\omega= 2\pi c/\lambda, we obtain

τ=δlc≈λθ24n02c=πθ22n02ω.(57)\tau= \frac{\delta l}{c} \approx\frac{\lambda\theta^2}{4n_0^2c} = \frac{\pi\theta^2}{2n_0^2\omega}. \tag*{(57)}

Thus, the time delay is given by

τ≈πθ22n02ω,(58)\tau\approx\frac{\pi\theta^2}{2n_0^2\omega}, \tag*{(58)}

where θ\theta must be expressed in radians.

To verify the validity of the quadratic approximation, we compare the exact OPD in Eq. (55) with the approximate expression in Eq. (56) over the experimental tilting-angle range of 0∘0^\circ–14∘14^\circ. At the maximum angle θ=14∘\theta= 14^\circ, the exact expression gives

δlexact=3.97903 nm,(59)\delta l_{\mathrm{exact}} = 3.97903\ \mathrm{nm}, \tag*{(59)}

whereas the quadratic approximation yields

δlapprox=3.98389 nm.(60)\delta l_{\mathrm{approx}} = 3.98389\ \mathrm{nm}. \tag*{(60)}

The absolute difference is

∣δlapprox−δlexact∣=4.86×10−3 nm,(61)\left|\delta l_{\mathrm{approx}}-\delta l_{\mathrm{exact}}\right| = 4.86 \times10^{-3}\ \mathrm{nm}, \tag*{(61)}

corresponding to a relative error of approximately 0.122%. The relative error is smaller at lower tilting angles and vanishes as θ→0\theta\to0. Thus, over the experimental range, the quadratic approximation provides an accurate description of the tilt-induced delay, with a maximum relative error of approximately 0.13%.

In our experiment, tilting the HWP about the xx-axis can induce a transverse beam displacement due to Snell’s law, which manifests as a fringe shift along the yy-axis. However, our optical geometry allows us to distinguish this geometrical effect from the time-delay-induced signal. Specifically, the slits are oriented along the xx-axis, and the time delay is encoded in the interference-fringe displacement along the xx-axis. Thus, the geometrical displacement associated with refraction, which occurs primarily along the yy-axis, does not contribute directly to the measured xx-direction signal.

A slight fringe displacement along the yy-axis can indeed be observed in the revised Figure 1, consistent with the geometrical effect described above. The same effect is also visible in our previous publication [Phys. Rev. Lett. 134, 080802 (2025)]. We have clarified the relevant geometry in the revised manuscript to distinguish the refraction-induced displacement from the time-delay-dependent fringe shift.

Experimental Dataset and Code Availability

The experimental data and MATLAB processing scripts supporting this work are publicly available in the dataset repository [36]. The repository includes data and code for five estimators: CCD fringe displacement (Δx\Delta x), PDQ differential voltage (XDIFF), lock-in output phase (η\eta), PDQ total voltage (SUM), and CCD-detected average photon number (NrN_r). Data are provided for input laser powers of 0.5, 5, and 50 mW, together with GNUPLOT scripts for reproducing the figures.

The repository structure is as follows:

2026–LockIn+RWVA_dataset/
├── CCD/                                      # Data and code for CCD Estimation
│   └── Input0.5mW/                           # Corresponding to 0.5 mW input laser power
│       ├── *.m                               # MATLAB data-processing code
│       ├── *.mat, *.txt                      # Processed data and results
│       └── *.pdf                             # Documentation of data processing results
├── Gnuplot_main_Letter/                      # Used for figures in the main Letter
│   ├── *.plt                                # GNUPLOT plotting scripts
│   ├── *.txt                                # Data required for plotting
│   ├── *.pdf                                # Generated PDF figures
│   └── *.bmp                                # Measured bitmap images
└── PDQ/                                      # PDQ experimental data and processing code
    ├── 0.5mW/                               # Corresponding to 0.5 mW input laser power
    ├── 5mW/                                 # Corresponding to 5 mW input laser power
    ├── 50mW/                                # Corresponding to 50 mW input laser power
    │   ├── *.m                             # MATLAB data-processing code
    │   ├── *.csv, *.txt                    # Raw records and processed results
    │   └── *.pdf                            # Documentation of data processing results
Repository structure of the dataset repository

Figure 9. Repository structure of the dataset repository.

The CCD/ and PDQ/ directories contain experimental data and MATLAB processing scripts, while Gnuplot main Letter/ contains plotting scripts and associated data files. Due to their large size, the original CCD images used for the complete Allan-deviation analysis are not included; the corresponding one-dimensional time-series data are provided.

References

  1. [1]Y. Aharonov, D. Z. Albert, and L. Vaidman, Phys. Rev. Lett. 60, 1351 (1988).
  2. [2]N. W. M. Ritchie, J. G. Story, and R. G. Hulet, Phys. Rev. Lett. 66, 1107 (1991).
  3. [3]J. Dressel, M. Malik, F. M. Miatto, A. N. Jordan, and R. W. Boyd, Rev. Mod. Phys. 86, 307 (2014).
  4. [4]L. Xu and L. Zhang, Progress in Quantum Electronics 96, 100518 (2024).
  5. [5]J. Zhu, L. Ye, Y. Wang, Y. Liu, Y. Jiang, A. Wang, J. Wu, and Z. Zhang, Applied Physics Reviews 12, 021315 (2025).
  6. [6]O. Hosten and P. Kwiat, Science 319, 787 (2008).
  7. [7]H. Luo, X. Zhou, W. Shu, S. Wen, and D. Fan, Phys. Rev. A 84, 043806 (2011).
  8. [8]S. Chen, X. Ling, W. Shu, H. Luo, and S. Wen, Phys. Rev. Appl. 13, 014057 (2020).
  9. [9]P. B. Dixon, D. J. Starling, A. N. Jordan, and J. C. Howell, Phys. Rev. Lett. 102, 173601 (2009).
  10. [10]C. Versmold, J. Dziewior, F. Huber, E. Köster, G. Reznik, L. Vaidman, and H. Weinfurter, Phys. Rev. Lett. 135, 253802 (2025).
  11. [11]Q. Cao, L. Xu, Z. Yue, J. Yang, and Y. Zhai, Photon. Res. 14, 544 (2026).
  12. [12]A. Feizpour, X. Xing, and A. M. Steinberg, Phys. Rev. Lett. 107, 133603 (2011).
  13. [13]M. Hallaji, A. Feizpour, G. Dmochowski, J. Sinclair, and A. M. Steinberg, Nature Physics 13, 540 (2017).
  14. [14]O. S. Magaña Loaiza, M. Mirhosseini, B. Rodenburg, and R. W. Boyd, Phys. Rev. Lett. 112, 200401 (2014).
  15. [15]N. Brunner and C. Simon, Phys. Rev. Lett. 105, 010405 (2010).
  16. [16]G. Strübi and C. Bruder, Phys. Rev. Lett. 110, 083605 (2013).
  17. [17]X.-Y. Xu, Y. Kedem, K. Sun, L. Vaidman, C.-F. Li, and G.-C. Guo, Phys. Rev. Lett. 111, 033604 (2013).
  18. [18]J.-H. Huang, K. M. Jordan, A. C. Dada, X.-Y. Hu, and J. S. Lundeen, Phys. Rev. Lett. 134, 080802 (2025).
  19. [19]J.-H. Huang, J. Huang, H.-L. Cui, T. Chang, H. Chen, Q. Du, H. Zhou, and X.-Y. Hu, Opt. Express 34, 33967 (2026).
  20. [20]J. Sinclair, M. Hallaji, A. M. Steinberg, J. Tollaksen, and A. N. Jordan, Phys. Rev. A 96, 052128 (2017).
  21. [21]A. N. Jordan, J. Martínez-Rincón, and J. C. Howell, Phys. Rev. X 4, 011031 (2014).
  22. [22]J. Harris, R. W. Boyd, and J. S. Lundeen, Phys. Rev. Lett. 118, 078082 (2017).
  23. [23]L. Xu, Z. Liu, A. Datta, G. C. Knee, J. S. Lundeen, Y. Q. Lu, and L. Zhang, Phys. Rev. Lett. 125, 080501 (2020).
  24. [24]J.-H. Huang, X.-Y. Hu, A. C. Dada, J. S. Lundeen, K. M. Jordan, H. Chen, and J. An, Phys. Rev. A 106, 053704 (2022).
  25. [25]J.-H. Huang and X.-Y. Hu, Phys. Rev. A 113, 033711 (2026).
  26. [26]C. Zhang, Y. Lai, R. Yang, K. Liu, J. Zhang, H. Sun, and J. Gao, Applied Physics Letters 122, 031107 (2023).
  27. [27]X. Qiu, L. Xie, X. Liu, L. Luo, Z. Li, Z. Zhang, and J. Du, Applied Physics Letters 110, 071105 (2017).
  28. [28]Z. Luo, Y. Yang, Z. Wang, M. Yu, C. Wu, T. Chang, P. Wu, and H.-L. Cui, Opt. Express 28, 25935 (2020).
  29. [29]Y. Jiang, J. Wu, R. Ge, and Z. Zhang, Opt. Lett. 50, 2938 (2025).
  30. [30]Y. Liu, Y. Zhang, Z. Xu, L. Zhou, Y. Zou, B. Zhang, and Z. Hu, Opt. Express 30, 18966 (2022).
  31. [31]Q. Song, H. Li, D. Wang, C. Yu, X. Wu, J. Huang, C. Wang, and G. Zeng, Laser & Photonics Reviews n/a, e02072.
  32. [32]I. K. Kominis, T. W. Kornack, J. C. Allred, and M. V. Romalis, Nature 422, 596 (2003).
  33. [33]M. Guizar-Sicairos, S. T. Thurman, and J. R. Fienup, Opt. Lett. 33, 156 (2008).
  34. [34]C. M. Caves, Phys. Rev. D 23, 1693 (1981).
  35. [35]Teledyne FLIR, “Emva 1288 imaging performance: Sony imx264,” softwareservices.flir.com, quantum efficiency of 46.11% at 630 nm for the red channel.
  36. [36]J.-H. Huang, “Data for: Optimal Estimation in Weak Value Amplification with a Position Pointer,” (2026), https://doi.org/10.7910/DVN/HQN10M.

Paper details

vlnc:W_48p5999h
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 11

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents