WorksPhysics and Astronomy

Synthesized complex-frequency excitation for ultrasensitive molecular sensing

Abstract

Detecting trace molecules remains a significant challenge. Surface-enhanced infrared absorption (SEIRA) based on plasmonic nanostructures, particularly graphene, has emerged as a promising approach to enhance sensing sensitivity. While graphene-based SEIRA offers advantages such as ultrahigh sensitivity and active tunability, intrinsic molecular damping weakens the interaction between vibrational modes and plasmons. Here, we demonstrate ultrahigh-sensitive molecular sensing based on synthesized complex-frequency waves (CFW). Our experiment shows that CFW can amplify the molecular signals (~1.2-nm-thick silk protein layer) detected by graphene-based sensor by at least an order of magnitude and can be universally applied to molecular sensing in different phases. Our approach is highly scalable and can facilitate the investigation of light-matter interactions, enabling diverse potential applications in fields such as optical spectroscopy, metasurfaces, optoelectronics, biomedicine and pharmaceutics.

Introduction

Sensors have emerged as indispensable analytical tools across a wide range of important fields, encompassing environmental monitoring, food safety, and public health[1, 2, 3, 4, 5]. They facilitate early disease diagnosis, personalized medicine, and rapid detection of toxic agents[6, 7, 8, 9]. However, significant challenges still exist in the effective detection of trace molecules, hindering the further development of sensors in these applications[6, 10, 11]. Many efforts have been made to improve the sensor sensitivity. Among the various methods explored, optical biosensors based on surface-enhanced infrared absorption (SEIRA) have attracted much attention due to their label-free nature, molecular specificity, and noninvasive performance[9, 12, 13, 14]. Through strong light-matter interactions achieved by surface-plasmon polaritons (SPPs), SEIRA can enhance the detection sensitivity of the molecular vibrational fingerprints in the infrared (IR) region[15, 16, 17]. SEIRA was first demonstrated in 1980 using Ag and Au thin films[18]. However, it was not widely adopted due to the limitation of nanofabrication techniques at the time[19]. The advancement of nanofabrication and new plasmonic materials (e.g., graphene, Ge, Si, oxides, and carbon nanotubes (CNTs)) have led to the revitalization of the research in this area in recent years[13]. In particular, plasmonic nanostructures have been proved to possess much greater enhancement of biomolecule signals than metallic thin films[17].

Compared to metal-based SEIRA, strong field confinement supported by two-dimensional (2D) Dirac fermion electronic states enables graphene-based SEIRA with excellent performance in molecular characterization for gas[20] and solid phase sensing[1, 21, 22]. Graphene can also enhance molecular IR absorption in aqueous solution[23]. Most importantly, active tunability of graphene plasmons broadens their detection frequency range for different molecular vibrational modes by changing the doping level via gate voltage[16, 24, 25]. These advantages make graphene-based SEIRA a unique platform for single-molecule detection. However, the intrinsic molecular damping largely reduces the interaction between the vibrational modes and plasmons. As a result, at lower concentrations, the spectra of plasmon-enhanced molecular signals become weaker and broader, and ultimately are overshadowed by noise.

One way to compensate for molecular damping is to add optical gain materials[26, 27, 28]. However, this requires a complex setup which may not be compatible with the detection system. In addition, gain materials usually increase instability and noise[29, 30]. Another way is to use complex-frequency waves (CFW); theoretical studies have proved that CFW with temporal attenuation can restore information loss due to material losses[31, 32]. However, producing CFW in real optical systems remains a challenging task. A novel method for synthesizing CFW has recently been proposed[33]. This method involves treating CFW as a coherent combination of multiple real-frequency waves based on the concept of the Fourier transform. This multi-frequency approach has been recently applied to superimaging[33] and shown remarkable improvement in the imaging resolution, but its application to sensors has not yet been attempted.

Here, we demonstrate dramatic signal enhancements of the molecular vibrational fingerprints governed by synthesized CFW. We first theoretically confirm that the truncated CFW synthesized by discretized real frequency waves in a limited range can effectively compensate for molecular damping, significantly improving trace molecular signals (~1.2-nm-thick silk protein layer). Synthesized CFWs are successfully applied to enhancing the molecular signals in the mid-IR extinction spectrum for biomolecules under different conditions, including direct measurement of multiple vibrational modes of deoxynivalenol (DON) molecules and graphene-based SEIRA of proteins in the solid phase and aqueous solution. The results show that our method can improve the sensitivity of various sensors by almost an order of magnitude and advance the quantitative detection of molecules.

Theoretical mechanism

Without loss of generality, we model a molecular layer using the Drude-Lorentz dispersion,

ε(ω)=1+∑mωpm2ωm2−ω2−iγmω(1)\varepsilon(\omega) = 1 + \sum_m \frac{\omega_{\mathrm{pm}}^2}{\omega_m^2-\omega^2-\mathrm{i}\gamma_m\omega} \tag*{(1)}

For simplicity, we assume the molecular layer has two vibrational modes, where the plasma frequencies ωp1=ωp2=128 cm−1\omega_{\mathrm{p1}}=\omega_{\mathrm{p2}}=128\ \mathrm{cm}^{-1}, the damping rates γ1=γ2=γM=60 cm−1\gamma_1=\gamma_2=\gamma_{\mathrm{M}}=60\ \mathrm{cm}^{-1}, and the resonant frequencies ω1=1553 cm−1\omega_1=1553\ \mathrm{cm}^{-1}, ω2=1666 cm−1\omega_2=1666\ \mathrm{cm}^{-1}. Using finite-element method (FEM) simulation, we obtain the extinction spectra of the molecular layer (the light blue curve in Fig. 1a). Obviously, the key to making the resonant peaks more pronounced is to reduce the damping rate γM\gamma_{\mathrm{M}}. If ω\omega is replaced by a complex frequency ω~=ω−iγM/2\widetilde{\omega}=\omega-\mathrm{i}\gamma_{\mathrm{M}}/2, the permittivity of the molecular layer becomes a purely real value ε(ω~)=1+ωp12(ω12−ω2−γM2/4)+ωp12(ω22−ω2−γM2/4)\varepsilon(\widetilde{\omega})=1+\frac{\omega_{\mathrm{p1}}^2}{(\omega_1^2-\omega^2-\gamma_{\mathrm{M}}^2/4)}+\frac{\omega_{\mathrm{p1}}^2}{(\omega_2^2-\omega^2-\gamma_{\mathrm{M}}^2/4)}. This shows that CFW with suitable temporal attenuation can fully compensate for the damping of molecular vibrational modes. Due to the difficulty of generating CFW directly, we use a new method to synthesize the truncated CFW expressed as ET(t0)=E0e−iω~t0θ(t0)E_{\mathrm{T}}(t_0)=E_0e^{-\mathrm{i}\widetilde{\omega}t_0}\theta(t_0), where ω~=ω−iτ/2\widetilde{\omega}=\omega-\mathrm{i}\tau/2, and τ>0\tau>0 represents temporal attenuation. θ(t)\theta(t) is the time truncation function to avoid energy divergence, where θ(t0)=1\theta(t_0)=1 for t0≥0t_0\ge0, and θ(t0)=0\theta(t_0)=0 for t0<0t_0<0. Note that the time truncation will lead to appearance of sidebands around the resonances in the complex frequency spectra, which can be eliminated via appropriate average of the signal over time (Supplementary Information Note II). Based on the Fourier transform, ET(t0)E_{\mathrm{T}}(t_0) can be expanded into the integral of the real frequency components: ET(t0)=E02π∫−∞+∞1i(ω~−ω′)e−iω′t0dω′E_{\mathrm{T}}(t_0)=\frac{E_0}{2\pi}\int_{-\infty}^{+\infty}\frac{1}{\mathrm{i}(\widetilde{\omega}-\omega')}e^{-\mathrm{i}\omega't_0}\mathrm{d}\omega', where 1/i(ω~−ω′)1/\mathrm{i}(\widetilde{\omega}-\omega') is the Fourier coefficient. Naturally, any response in the system excited by the truncated CFW can be expressed as the integral of the real frequency response F(ω~)≈∫−∞+∞F(ω′)1i(ω~−ω′)ei(ω~−ω′)t0dω′/2πF(\widetilde{\omega})\approx\int_{-\infty}^{+\infty}F(\omega')\frac{1}{\mathrm{i}(\widetilde{\omega}-\omega')}e^{\mathrm{i}(\widetilde{\omega}-\omega')t_0}\mathrm{d}\omega'/2\pi in the quasi-steady state. In reality, for a sufficiently wide spectrum range, the integral can be discretized as,

F(ω~)≈∑nF(ωn)1i(ω~−ωn)ei(ω~−ωn)t0Δω/2π(2)F(\widetilde{\omega}) \approx\sum_n F(\omega_n)\frac{1}{\mathrm{i}(\widetilde{\omega}-\omega_n)}e^{\mathrm{i}(\widetilde{\omega}-\omega_n)t_0}\Delta\omega/2\pi \tag*{(2)}

Subsequently, we use equation (2) to calculate the extinction of the molecular layer at CFW. The extinction is represented as I(ω)=1−∣tM∣2I(\omega)=1-\lvert t_{\mathrm{M}}\rvert^2, where tM=t/tSt_{\mathrm{M}}=t/t_{\mathrm{S}}, and tt, tSt_{\mathrm{S}} are the transmission coefficients through the substrate with and without the molecular layer, respectively. For thin layer systems, tMt_{\mathrm{M}} can be approximated as[34],

tM(ω)≈11−iP(ω)(3)t_{\mathrm{M}}(\omega) \approx\frac{1}{1-\mathrm{i}P(\omega)} \tag*{(3)}

Where P(ω)=χe(ω)ωd(ns+1)cP(\omega)=\frac{\chi_{\mathrm{e}}(\omega)\omega d}{(n_{\mathrm{s}}+1)c}, nsn_{\mathrm{s}} is the refractive index of the substrate, dd is the molecular layer thickness and χe(ω)\chi_{\mathrm{e}}(\omega) is the effective susceptibility. Considering the difficulty of phase measurement in practice, we can extract the phase arg⁡(tM)\arg(t_{\mathrm{M}}) from the amplitude ∣tM∣\lvert t_{\mathrm{M}}\rvert through Kramers–Kronig relations[35] (see details in Figure S1),

arg⁡(tM(ω))=−1πP∫Rln⁡∣tM(ω′)∣ω−ω′ dω′(4)\arg(t_{\mathrm{M}}(\omega))=-\frac{1}{\pi}\mathcal{P}\int_{\mathbb{R}}\frac{\ln\lvert t_{\mathrm{M}}(\omega')\rvert}{\omega-\omega'}\,\mathrm{d}\omega' \tag*{(4)}

and then P(ω)P(\omega) can be deduced from tMt_{\mathrm{M}} using equation (3).

P(ω)=i(1tM(ω)−1)(5)P(\omega)=\mathrm{i}\left(\frac{1}{t_{\mathrm{M}}(\omega)}-1\right) \tag*{(5)}

Note that, similarly to equation (2), equation (4) can be discretized in actual calculation. Hence, the extinction I(ω~)I(\tilde{\omega}) for a CFW can be obtained by calculating the response P(ω~)P(\tilde{\omega}) from P(ω)P(\omega),

P(ω~)≈∑nP(ωn)1i(ω~−ωn)ei(ω~−ωn)t0Δω/2π(6)P(\tilde{\omega})\approx\sum_n P(\omega_n)\frac{1}{\mathrm{i}(\tilde{\omega}-\omega_n)}\mathrm{e}^{\mathrm{i}(\tilde{\omega}-\omega_n)t_0\Delta\omega/2\pi} \tag*{(6)}
I(ω~)=1−1∣1−iP(ω~)∣2(7)I(\tilde{\omega})=1-\frac{1}{\lvert1-\mathrm{i}P(\tilde{\omega})\rvert^2} \tag*{(7)}

Here we do not directly calculate tM(ω~)t_{\mathrm{M}}(\tilde{\omega}) to obtain I(ω~)I(\tilde{\omega}) because ∣tM(ω)∣→1\lvert t_{\mathrm{M}}(\omega)\rvert\to1 as ω→∞\omega\to\infty, which would cause relatively large errors in equation (2) from outside the finite frequency range. On the contrary, ∣P(ω)∣→0\lvert P(\omega)\rvert\to0 as ω→∞\omega\to\infty, making the numerical errors of P(ω~)P(\tilde{\omega}) smaller. Further, we time-average P(ω~)P(\tilde{\omega}) to reduce the error caused by the truncation of the CFW, the limited frequency range and discretization of frequencies (see details in Supplementary Material Note II). Accordingly, we set ω~=ω−iγM/2\tilde{\omega}=\omega-\mathrm{i}\gamma_{\mathrm{M}}/2 to demonstrate the enhancement effect of CFW. Compared to the original signal I(ω)I(\omega), the resonant peaks of I(ω~)I(\tilde{\omega}) (the dark blue curve in Figure 1a) are significantly narrowed, which means that synthesized CFW can directly enhance the molecular vibrational fingerprints without additional assistance.

Illustration of damping compensation for sensing enhancement through synthesized complex-frequency waves

Figure 1. Illustration of damping compensation for sensing enhancement through synthesized complex-frequency waves. (a) The extinction spectra of the molecular layer at real frequency (the light blue curve) and at CFW (the dark blue curve). The vibrational peaks are marked by the vertical lines. (b) The extinction spectra of the graphene nanoribbon at real frequency (the light green curve) and at CFW (the dark green curve). (c) The extinction spectrum of the molecular layer enhanced by GP at real frequency (the light red curve) and at CFW (the dark red curve). (d–f) The extinction maps under different EfE_f (d) with γM=60 cm−1\gamma_{\mathrm{M}} = 60\ \mathrm{cm}^{-1} at real frequency, (e) with γM=0\gamma_{\mathrm{M}} = 0 at real frequency and (f) with γM=60 cm−1\gamma_{\mathrm{M}} = 60\ \mathrm{cm}^{-1} at CFW. All CFW results are use equation (2) to calculate from the corresponding real frequency results.

At very low concentrations, the absolute response of the molecular layer would be too small to measure, so SEIRA is used to solve this issue. Here, we consider a graphene nanoribbon array with a period of Λ=200\Lambda= 200 nm, and ribbon width w=80w = 80 nm, where the surface conductivity of graphene σ\sigma can be calculated by the Kubo formula[35, 36, 37] (see Methods). The resonant frequency of graphene plasmon (GP) ωGP\omega_{\mathrm{GP}} is 1553 cm−1^{-1} for the doped graphene Fermi energy Ef=0.5E_{\mathrm{f}} = 0.5 eV (the light green curve in Figure 1b). We assume that the molecular layer covering the graphene nanoribbon and study the near-field coupling between GP and molecular vibrational modes. The light red curve in Figure 1c shows that the signals from such a thin molecular layer in the extinction spectra are very weak, even with the enhancement provided by GP. This phenomenon can be understood in terms of coupled harmonic oscillators[39]. Plasmon−phonon coupling generates two new hybrid modes, whose splitting distance and damping depend on their coupling strength and original damping rates γGP\gamma_{\mathrm{GP}} and γM\gamma_{\mathrm{M}}. Specially, the damping rates of the hybrid modes are equal to (γGP+γM)/2(\gamma_{\mathrm{GP}} + \gamma_{\mathrm{M}})/2 when the resonant frequencies of the plasmon and the molecular mode coincide (ωGP=ω1)(\omega_{\mathrm{GP}} = \omega_{1}). In the case of low concentrations, the hybrid-mode linewidth characterized by γGP\gamma_{\mathrm{GP}} and γM\gamma_{\mathrm{M}} is relatively larger than the splitting distance caused by the weak coupling strength, resulting in a large overlap between the two hybrid-mode broad peaks and a small dip that is difficult to detect in the extinction spectra. Similarly, we use synthesized CFW to recover the molecular signals. Note that even if the decay constant of graphene Γ\Gamma is generally much larger than γM/2\gamma_{\mathrm{M}}/2, CFW can still partially compensate for γGP\gamma_{\mathrm{GP}} (the dark green curve in Figure 1b), thereby narrowing the linewidths of hybrid modes. It is numerically confirmed that owing to the compensation by synthesized CFW, the originally weak signals are greatly enhanced, and phonon-induced transparency (PIT) structure[40] (ω1)(\omega_{1}) and Fano structure[41] (ω2)(\omega_{2}) are clearly visible in the spectra (The dark red curve in Figure 1c).

We also studied the effect of CFW under different Fermi energies. For the graphene nanoribbon, the resonance of GP gradually shifts to higher frequency with the increase of EfE_{\mathrm{f}}. Due to the relatively large damping, plasmon−phonon coupling has almost no effect on the linear dispersion of GP, such a weak perturbation produces almost no visible dip in the extinction spectrum (Figure 1d). If we set γM\gamma_{\mathrm{M}} close to 0, GP dispersion will be strongly affected near the resonance frequencies of the molecular vibrational modes and GP, as shown by the strong anti-crossing behavior (Figure 1e). We next obtain the spectrum at CFW (Figure 1f) by applying Eq. (2) to the spectrum at real frequencies (Figure 1d). The CFW spectrum exhibits strong anti-crossing behavior at the molecular vibrational resonance frequencies, similar to the case of negligible loss (Figure 1e). Thus, synthesized CFW can effectively enhances GP-based molecular signals through the damping compensation mechanism. In addition, obtaining the phase arg⁡(tM)\operatorname{arg}(t_{\mathrm{M}}) by Kramers–Kronig relations facilitate the applicability of the proposed synthesized CFW method.

Enhancement of molecular fingerprint signals

Based on the above theoretical analysis, we take measurements of molecular infrared spectra to showcase the effectiveness of the synthesized CFW method in enhancing sensitivity. In the experiment, Fourier transform infrared (FTIR) spectroscopy is used to measure the molecular infrared vibrational fingerprint spectrum (details in Methods), where the infrared beam excites the molecular vibrations and is absorbed at the specific resonance frequencies (Figure 2a). We start with deoxynivalenol (DON) molecules, a mycotoxin from Fusarium fungi found in cereals which poses health risks to humans and animals. The optical micrograph (Figure 2b) illustrates the preparation of DON samples on a Si substrate (details in Methods). It should be noted that the granular shape of DON molecules is mainly due to solvent evaporation and intermolecular interactions.

Direct observation of molecular vibration infrared signals and the enhancement effect of synthesized complex-frequency waves

Figure 2. Direct observation of molecular vibration infrared signals and the enhancement effect of synthesized complex-frequency waves. (a) Schematic illustration of molecular infrared spectroscopy measurements. The infrared beam is incident upon the molecular film, spin-coated on the Si substrate, to excite the infrared fingerprint vibrational signal. (b) Optical microscope image showing the deposition of deoxynivalenol (DON) molecules on Si substrate. After spin coating, the molecules recrystallize into raised particle shapes. Scale bar: 10 μm10\,\mu\mathrm{m}. (c) Vibrational extinction spectrum of DON molecules. The gray curve represents the experimentally measured extinction spectrum, while the black curve represents the extinction spectrum enhanced by the complex frequency technique. The vertical lines highlight the characteristic vibrational peaks of the molecules.

Due to the large number of molecules in DON particles, the signal intensity after infrared spectroscopy measurement is relatively strong, as shown in the grey curve in Figure 2c. However, the spin-coated molecules exhibit disorder and have a low-quality factor, resulting in a significant broadening of C-O-H bending modes (δ(C−O−H)\delta(\mathrm{C-O-H})) which have fingerprints between 1400-1455 cm−1\mathrm{cm}^{-1} (as indicated by the dashed lines), making them difficult to discern in the extinction spectra. We employed CFW in conjunction with the Kramers–Kronig relation to process the original extinction spectrum (grey curve), obtaining the new spectrum (black curve) in Figure 2c, clearly displaying the narrowing of the spectral linewidth and enhanced characteristic intensity. This enhancement has allowed us to identify molecular structures and properties more precisely and accurately, contributing significantly to our understanding of molecular spectroscopy.

Enhancing the sensitivity of graphene-based sensors

When the molecular layer is thin, or the number of molecules is very small, traditional infrared spectroscopy struggles to effectively probe molecular signals. Currently, graphene-based SEIRA is one of the most sensitive enhanced infrared spectroscopy methods. For implementation, we first soak a graphene-based infrared sensor in a silk protein solution at a concentration of 10 μg/mL10\,\mu\mathrm{g}/\mathrm{mL} to enable the protein molecules to adhere to the surface of graphene nanoribbons. The examination of how CFW techniques can enhance the sensors' detection sensitivity is then carried out. Figure 3a illustrates the schematic of the characterization of GP-enhanced molecular vibrational signal on the periodic graphene nanoribbons. The principle of graphene-based SEIRA is as follows: an infrared light beam irradiates the periodic graphene nanoribbons (Figure 3b) to excite GP to achieve electromagnetic field enhancement; then, through dynamic back-gate tuning, the resonant frequency of GP is adjusted to be close to the molecular characteristic fingerprint vibrational frequency, resulting in phonon-induced transparency (PIT) in the extinction spectra, as shown in Figure 3c. The dashed lines indicate the characteristic mode of the protein, representing the Amide I band (1626 cm−11626\,\mathrm{cm}^{-1}).

Enhancing the sensitivity of graphene-based sensors and monitoring different molecular layer thicknesses

Figure 3. Enhancing the sensitivity of graphene-based sensors and monitoring different molecular layer thicknesses. (a) Schematic of the graphene-based sensor. Gate voltage modulation enables GP-enhanced detection of molecular signals. (b) The scanning electron microscopy (SEM) image of the graphene-based sensor showcases its distinctive design, characterized by periodic nanoribbons that enhance its sensing capabilities. The width of the graphene nanoribbon is approximately 50 nm, and the period is approximately 100 nm. (c) Direct experimental response of the GP infrared sensor with different thicknesses of silk protein (see details in Figure S3) and (d) the response enhanced by synthesized CFW. The characteristic vibrational peak of the protein are marked by the vertical line. (e) A comparison of the GP-enhanced signals is shown. The sensitivity is scaled by the dip depths Δh\Delta h in (c-d).

We then investigate the extinction spectrum of GP with different thicknesses (∼1.2 nm\sim1.2\,\mathrm{nm}, ∼2.1 nm\sim2.1\,\mathrm{nm}, ∼3.0 nm\sim3.0\,\mathrm{nm}, and ∼5.8 nm\sim5.8\,\mathrm{nm}) of silk proteins on graphene nanoribbons (see details in Figure S3). As the thickness of silk protein increases, there is a corresponding increase in the intensity of the molecular characteristic vibration signal, and the dip of GP-enhanced molecular coupling gradually deepened, as shown in Figure 3c. However, for silk protein thicknesses of less than 2 nm, the ultra-low coupled signal between graphene and silk protein makes it difficult to identify the vibration signals of the silk protein, which has been a common challenge encountered in the detection of trace proteins. Here, synthesized CFW method is utilized to greatly enhance the signal in the molecular protein growth process, allowing for clear identification of the dips generated at different thicknesses of silk protein, as shown in Figure 3d. The dip depth Δh\Delta h is used as the figure of merit to quantitatively evaluate the sensitivity of the graphene-based sensor42,43. Δh\Delta h is extracted for both real frequency spectra (Figure 3c) and CFW spectra (Figure 3d) and plotted in Figure 3e, demonstrating that the sensitivity has increased by almost one order of magnitude using the CFW method. For the thinnest molecular layer (∼1.2\sim1.2 nm), the enhancement factor reaches 15. These results highlight the potential of graphene-based sensors for providing highly sensitive and accurate detection of molecular fingerprints.

Enhancing the sensitivity of tunable graphene-based liquid phase sensors

We further apply our method to sensing molecules in aqueous solution, employing a liquid-phase GP-enhanced FTIR experimental setup as depicted in Figure 4a, which can eliminate the water background outside the GP hotspot. This setup involves a GP-enhanced infrared sensor encapsulated in an infrared-transparent microfluidic system, allowing a transmittance measurement and a steady solution flowing path. In an aqueous environment, the abundant ions form an electric double layer (EDL) on charged surfaces-graphene. Thus, a liquid gate is applied, which enables a stable and tunable plasmon response of the graphene nanoribbons in an aqueous environment. Then, by injecting a bovine serum albumin (BSA) protein solution (1 mg/mL) into the microfluidic system for two hours, protein molecules become saturated and adsorbed onto the graphene nanoribbons. This leads to the appearance of two dips in the extinction spectrum corresponding to the amide I band (1655 cm−1^{-1}) and amide II band (1545 cm−1^{-1}) of the BSA protein, as shown in Figure 4b. The resonant frequency of GP ωGP\omega_{\mathrm{GP}} in the infrared fingerprint region can be dynamically adjusted by modulating the doped graphene Fermi energy EfE_{\mathrm{f}} using the liquid gate ΔVg\Delta V_{\mathrm{g}}. Increasing ΔVg\Delta V_{\mathrm{g}} from 1.1 V to 2.1 V leads to a blue shift in ωGP\omega_{\mathrm{GP}}.

Enhancing the sensitivity of liquid phase in situ infrared detection

Figure 4. Enhancing the sensitivity of liquid phase in situ infrared detection. (a) Schematic diagram of a liquid-phase GP infrared sensor. The black V is the voltage applied between the source and the drain electrodes, and the red V is the top-gate voltage. (b) The dashed curves represent experimental results (see details in Figure S4) of the extinction at different gate voltages ΔVg\Delta V_{\mathrm{g}}, while the solid curves show the signals enhanced by CFW method. The experimental data were collected after 1 mg/mL protein solution flowed for 2 hours, with the graphene nanoribbon width being approximately 50 nm and the period being approximately 120 nm. The characteristic vibrational peaks of the protein are marked by the vertical lines. (c) The simulation extinction map under different ΔVg\Delta V_{\mathrm{g}} by CFW method. The hollow points are the position of dips obtained from experimental results at different ΔVg\Delta V_{\mathrm{g}} (1.1 V, 1.3 V, 1.5 V, 1.7 V, 1.9 V, 2 V, 2.1 V) by the CFW method.

Due to significant damping and the presence of noise in an aqueous solution, the two characteristic resonances of the molecule (the dashed curves in Figure 4b) appear to be indistinct, particularly at larger detuning between GP and the molecular vibrational modes. Here, by applying the CFW method, we observe significantly enhanced signals in the spectrum (the solid curves in Figure 4b), clearly showing that with an increase of ΔVg\Delta V_{\mathrm{g}}, the detuning first decreases and then increases, causing the line-shapes of the two dips to gradually transform from Fano to PIT, and then back to Fano resonances. At Fano resonances, the dips slightly deviate from the molecular vibrational modes, which is consistent with the theory (Figure 1c). Moreover, we simulated the extinction in aqueous solution (the map in Figure 4c). We show that the position of dips in the experimental spectra at CFW (the hollow points in Figure 4c) conforms to the evolution trend of the simulation, further proving the rationality of CFW method. Therefore, synthesized CFW method is also suitable for enhancing the sensitivity of liquid-phase infrared sensors even under very challenging conditions.

Conclusions

In conclusion, we have applied a novel synthesized CFW method to compensate for the intrinsic damping of the detected molecules and sensors, resulting in a large enhancement in the signals of the molecular vibrational fingerprints. We demonstrate that for different experimental scenarios, including DON molecules without plasmonic enhancement and silk protein molecules and BSA protein solutions measured by graphene-based plasmonic sensors, synthesized CFW method can effectively enhance the characteristic signals, exhibiting its wide applications. Importantly, under the condition of low concentrations or thin thicknesses, the CFW method can dramatically improve the signals, which is beneficial to increase the upper limit of sensitivity for various sensors. The CFW technique presents a new platform for the sensing field, enabling the enhancement of sensing sensitivity in complex environments and laying the foundation for environmental monitoring, healthcare diagnosis, and new material development.

Methods

Simulation of transmission spectrum

The thin layer system consists of the molecular layer and graphene nanoribbon and is simulated by finite-element method (FEM) using COMSOL Multiphysics software. In the simulation, a transverse magnetic wave is normally incident onto the thin layer with periodic boundary conditions, and then the transmission coefficient is obtained. In addition, the surface conductivity of graphene σ\sigma used in the simulation is calculated by the Kubo formula,

σ=ie2Efπℏ2(ω+iΓ)+ie24πℏln⁡[2∣Ef∣−(ω+iΓ)2∣Ef∣+(ω+iΓ)]\sigma= \frac{ie^{2}E_{\mathrm{f}}}{\pi\hbar^{2}(\omega+i\Gamma)}+\frac{ie^{2}}{4\pi\hbar}\ln\left[\frac{2|E_{\mathrm{f}}|-(\omega+i\Gamma)}{2|E_{\mathrm{f}}|+(\omega+i\Gamma)}\right]

The temperature T=300T=300 K satisfies the approximate requirement of KBT≪EfK_{\mathrm{B}}T \ll E_{\mathrm{f}}, ee is the electron charge, ω\omega is the angular frequency, ℏ\hbar is the reduced Planck constant, and EfE_{\mathrm{f}} is the doped graphene Fermi energy. The relaxation time Γ=evf2/μEf\Gamma=ev_{\mathrm{f}}^{2}/\mu E_{\mathrm{f}}, where vf=c/300v_{\mathrm{f}}=c/300 is the Fermi velocity and μ=700\mu=700 cm2^{2}V−1^{-1}s−1^{-1} is the carrier mobility of graphene.

Graphene Plasmonic IR Biosensing

For silk protein detection, the proposed graphene plasmon infrared sensor was composed of connected graphene nanoribbon arrays patterned on a 285 nm SiO2_{2}/500 μ\mum substrate (from Silicon Valley Microelectronics, Inc.) using electron beam lithography (Vistec 5000+ES, Germany) and oxygen plasma etching (SENTECH, Germany). The monolayer graphene film was grown on copper foil by chemical vapor deposition and transferred to a SiO2_{2}/Si substrate using the wet transfer method. The graphene nanoribbon arrays were designed to have widths ranging from 50 nm to 100 nm, with a gap of 50 nm to 100 nm. A pair of electrodes (5 nm Ti and 50 nm Au) were patterned and evaporated onto the graphene using electron-beam lithography combined with electron beam evaporation (OHMIKER-50B, Taiwan). The back-gate was applied by connecting the electrode to the backside of the SiO2_{2}/Si substrate using an external circuit with the help of silver thread. The SourceMeter (Keithley 2636B) was utilized to supply varied gate voltages.

For BSA protein solution detection, based on the previous setup of the graphene plasmon infrared sensor, a top-gate electrode was evaporated onto the substrate, which was connected to the solution but not to the graphene nanoribbons. Additionally, the source and drain electrodes were further passivated with a 50 nm PMMA layer to prevent direct interaction between the electrodes and protein molecules, as well as to minimize electrolyte leakage between the source and gate. The graphene plasmon infrared sensor was then encapsulated with a microfluidic system. Finally, the electrodes were led outside the microfluidic system and connected to the external circuit using silver thread.

Characterization of the Graphene Plasmon Infrared Sensor

The morphologies and thicknesses of the fabricated graphene nanoribbons were characterized by employing scanning electron microscopy (NOVA Nano SEM 430) and AFM (Bruker Multimode8) measurements. The transfer characteristic curve was determined by using a source meter (Keithley 2636B). The FTIR transmission measurements were performed with Thermo Fisher Nicolet iN10 with an IR microscope (15× objective). The aperture was set as 100 μm×200 μm100\ \mu\mathrm{m} \times200\ \mu\mathrm{m} for each measurement, while the resolution was 4 cm−14\ \mathrm{cm}^{-1} and scans were 128.

The chemicals sampling

The DON solution was prepared by dissolving DON powder in alcohol at a concentration of 0.5 μg/mL0.5\ \mu\mathrm{g}/\mathrm{mL}. Subsequently, it was dropped onto a Si substrate. Once the alcohol evaporates, the DON molecules remain deposited on the substrate. The 10 μg/mL10\ \mu\mathrm{g}/\mathrm{mL} silk protein solution was prepared by diluting 50 mg/mL50\ \mathrm{mg}/\mathrm{mL} silk fibroin solution (from Sigma) 5000 times with deionized water. The BSA protein solution was prepared by dissolving Bovine albumin Fraction V (from Sigma) in deionized water. The different thicknesses of silk protein on graphene nanoribbons were prepared by soaking the graphene plasmon infrared sensor in silk protein solution for varying durations. (2014).

Data availability

The data that support the findings of this study are available from the corresponding author upon reasonable request.

Acknowledgments

This work was supported by the New Cornerstone Science Foundation, the Research Grants Council of Hong Kong AoE/P-502/20, 17309021 (to S.Z.); National Natural Science Foundation of China (51925203 to Q.D. and 52102160 to X.G.).

Author contributions

S. Z. and Q.D. conceived the project. K.Z. and X.G. performed numerical simulations. K.Z. and F.G. performed analytical calculations. C.W. conducted the experiments with the help of Y.D. under the supervision of X.Y. and Q.D.; K.Z., C.W., and X.G. processed the experimental data. K.Z., C.W., X.G., F.G., X.Y., N.L., Q.D. and S.Z. analyzed the experimental results. L.L.Z and K.Z. performed the analysis of the signal sidebands under the truncated CFW excitation. K.Z., X.G., C.W., L.L.Z., N.L., Q.D. and S.Z. wrote the manuscript with input from all authors. All authors contributed to the discussion.

Additional information

Supplementary information is available in the online version of the paper. Reprints and permissions information is available online at www.nature.com/reprints.

Correspondence and requests for materials should be addressed to X.Y., N.L., Q.D., S.Z.

Competing interests

The authors declare no competing financial interests.

References

  1. [1]Rodrigo, D. et al. Mid-infrared plasmonic biosensing with graphene. Science 349, 165-168, (2015).
  2. [2]Tittl, A. et al. Imaging-based molecular barcoding with pixelated dielectric metasurfaces. Science 360, 1105-1109, (2018).DOI
  3. [3]Liu, N. et al. Plasmonic analogue of electromagnetically induced transparency at the Drude damping limit. Nat Mater 8, 758-762, (2009).DOI
  4. [4]Basov, D. N., Fogler, M. M. & Garcia de Abajo, F. J. Polaritons in van der Waals materials. Science 354, (2016).pubmed.ncbi.nlm.nih.gov/27738142
  5. [5]Chikkaraddy, R. et al. Single-molecule strong coupling at room temperature in plasmonic nanocavities. Nature 535, 127-130, (2016).pubmed.ncbi.nlm.nih.gov/27296227
  6. [6]Sreekanth, K. V. et al. Extreme sensitivity biosensing platform based on hyperbolic metamaterials. Nat Mater 15, 621-627, (2016).DOI
  7. [7]Baumberg, J. J., Aizpurua, J., Mikkelsen, M. H. & Smith, D. R. Extreme nanophotonics from ultrathin metallic gaps. Nat Mater 18, 668-678, (2019).DOI
  8. [8]Oh, S. H. et al. Nanophotonic biosensors harnessing van der Waals materials. Nat Commun 12, 3824, (2021).DOI
  9. [9]Altug, H., Oh, S. H., Maier, S. A. & Homola, J. Advances and applications of nanophotonic biosensors. Nat Nanotechnol 17, 5-16, (2022).DOI
  10. [10]Li, Y. et al. Graphene plasmon enhanced vibrational sensing of surface-adsorbed layers. Nano Lett 14, 1573-1577, (2014).DOI
  11. [11]Lee, I. H., Yoo, D., Avouris, P., Low, T. & Oh, S. H. Graphene acoustic plasmon resonator for ultrasensitive infrared spectroscopy. Nat Nanotechnol 14, 313-319, (2019).DOI
  12. [12]Adato, R. & Altug, H. In-situ ultra-sensitive infrared absorption spectroscopy of biomolecule interactions in real time with plasmonic nanoantennas. Nat Commun 4, 2154, (2013).DOI
  13. [13]Yang, X. et al. Nanomaterial-Based Plasmon-Enhanced Infrared Spectroscopy. Adv Mater 30, e1704896, (2018).DOI
  14. [14]John-Herpin, A. et al. Metasurface-Enhanced Infrared Spectroscopy: An Abundance of Materials and Functionalities. Adv Mater, e2110163, (2022).
  15. [15]Koppens, F. H., Chang, D. E. & Garcia de Abajo, F. J. Graphene plasmonics: a platform for strong light-matter interactions. Nano Lett 11, 3370-3377, (2011).DOI
  16. [16]Low, T. et al. Polaritons in layered two-dimensional materials. Nat Mater 16, 182-194, (2017).DOI
  17. [17]Zeng, S., Baillargeat, D., Ho, H.-P. & Yong, K.-T. Nanomaterials enhanced surface plasmon resonance for biological and chemical sensing applications. Chemical Society Reviews 43, 3426-3452, (2014).DOI
  18. [18]Hartstein, A., Kirtley, J. & Tsang, J. Enhancement of the infrared absorption from molecular monolayers with thin metal overlayers. Physical Review Letters 45, 201, (1980).DOI
  19. [19]Tanaka, T., Yano, T.-a. & Kato, R. Nanostructure-enhanced infrared spectroscopy. Nanophotonics 11, 2541-2561, (2021).DOI
  20. [20]Hu, H. et al. Gas identification with graphene plasmons. Nat Commun 10, 1131, (2019).DOI
  21. [21]Bylinkin, A. et al. Real-space observation of vibrational strong coupling between propagating phonon polaritons and organic molecules. Nature Photonics 15, 197-202, (2020).
  22. [22]Autore, M. et al. Boron nitride nanoresonators for phonon-enhanced molecular vibrational spectroscopy at the strong coupling limit. Light Sci Appl 7, 17172, (2018).
  23. [23]Wu, C. et al. Ultrasensitive Mid-Infrared Biosensing in Aqueous Solutions with Graphene Plasmons. Adv Mater 34, e2110525, (2022).DOI
  24. [24]Fei, Z. et al. Gate-tuning of graphene plasmons revealed by infrared nano-imaging. Nature 487, 82-85, (2012).DOI
  25. [25]Chen, J. et al. Optical nano-imaging of gate-tunable graphene plasmons. Nature 487, 77-81, (2012).DOI
  26. [26]Ramakrishna, S. A. & Pendry, J. B. Removal of absorption and increase in resolution in a near-field lens via optical gain. Physical review B 67, 201101, (2003).
  27. [27]Fang, A., Koschny, T., Wegener, M. & Soukoulis, C. Self-consistent calculation of metamaterials with gain. Physical review B 79, 241104, (2009).DOI
  28. [28]Grgic, J. et al. Fundamental limitations to gain enhancement in periodic media and waveguides. Physical review letters 108, 183903, (2012).DOI
  29. [29]Stockman, M. I. Spaser action, loss compensation, and stability in plasmonic systems with gain. Physical review letters 106, 156802, (2011).pubmed.ncbi.nlm.nih.gov/21568593
  30. [30]Pendry, J. & Maier, S. Comment on “Spaser action, loss compensation, and stability in plasmonic systems with gain”. Physical review letters 107, 259703, (2011).pubmed.ncbi.nlm.nih.gov/22243122
  31. [31]Archambault, A., Besbes, M. & Greffet, J.-J. Superlens in the time domain. Physical review letters 109, 097405, (2012).
  32. [32]Tetikol, H. S. & Aksun, M. I. Enhancement of Resolution and Propagation Length by Sources with Temporal Decay in Plasmonic Devices. Plasmonics 15, 2137-2146, (2020).arxiv.org/abs/1907.04415
  33. [33]Guan, F. et al. Overcoming losses in superlenses with synthetic waves of complex frequency. arXiv preprint arXiv:2303.16081, (2023).arxiv.org/abs/2303.16081
  34. [34]Zheng, G. et al. Metasurface holograms reaching 80% efficiency. Nature nanotechnology 10, 308-312, (2015).DOI
  35. [35]Chen, P.-Y. & Alu, A. Atomically thin surface cloak using graphene monolayers. ACS nano 5, 5855-5863, (2011).DOI
  36. [36]Guo, X. et al. Efficient All-Optical Plasmonic Modulators with Atomically Thin Van Der Waals Heterostructures. Adv Mater 32, e1907105, (2020).DOI
  37. [37]Guo, X., Hu, H., Zhu, X., Yang, X. & Dai, Q. Higher order Fano graphene metamaterials for nanoscale optical sensing. Nanoscale 9, 14998-15004, (2017).DOI
  38. [39]Yan, H., Low, T., Guinea, F., Xia, F. & Avouris, P. Tunable phonon-induced transparency in bilayer graphene nanoribbons. Nano letters 14, 4581-4586, (2014).
  39. [40]Fano, U. Effects of configuration interaction on intensities and phase shifts. Physical review 124, 1866, (1961).DOI
  40. [41]Gralak, B., Lequime, M., Zerrad, M. & Amra, C. Phase retrieval of reflection and transmission coefficients from Kramers–Kronig relations. JOSA A 32, 456-462, (2015).DOI

Paper details

vlnc:W_576uq9kf
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents