betaFeedback

WorksPhysics and Astronomy

Numerical Study of Flow and Cavitation in Single-Liquid Injectors with Sharp-Edged and Chamfered Orifice Inlets

Abstract

In the current work, the investigators used Computational Fluid Dynamics (CFD) to investigate water flow and cavitation in single-liquid injectors with sharp-edged and chamfered orifice inlets. The k-ω Shear Stress Transport (SST) turbulence model was used along with the Zwart-Gerber-Belamri (ZGB) cavitation model and the Volume of Fluid (VOF) method. The CFD predictions for the volumetric flow rate were validated against existing experimental data for the sharp-edged and chamfered orifice inlets. Pressure drops ranging between 0.07 MPa and 0.59 MPa were considered along with orifice length-to-diameter ratios of 2, 5, and 10. Strong cavitation was observed for the sharp-edged orifice inlet cases with a length-to-diameter ratio of 5 and a pressure drop larger than 0.2 MPa. A hydraulic flip was observed for the sharp-edged orifice inlet with a length-to-diameter ratio of 5 and a pressure drop of 0.59 MPa, which was consistent with the findings from the previous experimental study. Cavitation inception was observed for the chamfered orifice inlet cases with a length-to-diameter ratio of 5 and pressure drops larger than 0.2 MPa. For the sharp-edged orifice inlet with orifice length-to-diameter ratios of 2 and 10, a strong cavitation was observed inside the orifice.

Introduction

The orifice inlet geometry plays an important role in determining the pressure drop through a single-liquid rocket injector (Kiaoulias et al 2019). For repeatability in manufacturing and pressure drop values, sharp-edge and chamfered orifice inlets are used. Typical sharp-edge and chamfered geometries are shown in Figure 1. Pressure drop through the injector depends strongly on the diameter ratio, which is the ratio of the orifice diameter to the diameter at the inlet of the injector.

Schematic of sharp-edge orifice inlet and chamfered orifice inlet for a liquid injector

Figure 1. Schematic of (a) sharp-edge orifice inlet and (b) chamfered orifice inlet for a liquid injector.

Cold-flow experiments are generally utilized to test and design liquid rocket injectors. Typically, deionized or distilled water is used in the cold-flow (no combustion) experiments to simulate liquid fuel such as Hydrazine. Reitz and Bracco (1982) utilized cold-flow experiments to study the mechanism of atomization caused by liquid injectors with various sharp-edge and rounded inlet geometries. McHale and Nurick (1974) performed cold-flow experiments to investigate the flow through liquid injectors with non-circular orifices. Kiaoulias et al (2019) carried out cold-flow experiments (1,000 ≤Re≤\le Re \le 10,000) of single liquid injectors with sharp-edge and chamfered inlets. Here ReRe is the Reynolds number defined as

Re=ρVDμ(1)Re = \frac{\rho V D}{\mu} \tag*{(1)}

where ρ\rho is the density of water, VV is the mean velocity of water, DD is the diameter of the orifice, and μ\mu is the dynamic viscosity of water. Kiaoulias et al (2019) studied injectors with diameter ratios of 0.16, 0.4, and 0.52, and found large pressure drops across the injector for a sharp-edge inlet specifically for a small orifice with a diameter ratio of 0.16 and small L/DL/D of 2 and 5, where LL is the length of the orifice.

Flow through the injector with a sharp-edged orifice inlet, shown in Figure 1a, can simply be interpreted as flow through a sudden contraction. Several theoretical, empirical, and CFD studies of sudden contraction in pipes have been conducted in the past. Benedict et al (1966) developed compressible-flow solutions to predict the loss coefficient for a sudden contraction in a pipe for turbulent flow and validated the same against experiments for diameter ratios ranging from 0 to 1. Durst and Loy (1985) performed CFD studies to investigate laminar flow through a sudden contraction in a pipe (23 ≤Re≤\le Re \le 1213) with a diameter ratio of 0.53 and validated the CFD results against experiments. Bullen et al (1987) developed improved theoretical predictions of the loss coefficients for turbulent flow through sudden contractions (40,000 ≤Re≤\le Re \le 200,000) for diameter ratios ranging from 0 to 1. Their predictions compared closely with experimental data. Some of the researchers ([23] (Roul and Dash 2011)) utilized Reynolds Averaged Navier-Stokes (RANS) based models to predict turbulent flow in sudden contractions. Roul and Dash (2011) utilized CFD to study single and multi-phase flow through a sudden contraction (diameter ratio of 0.53) in a pipe for laminar and turbulent flow (1,000 ≤Re≤\leq Re \leq 12,000). They modeled turbulent flow by utilizing the realizable kk-ε\varepsilon model. Kaushik et al [23] studied turbulent, multiphase flow through a sudden contraction in a pipe numerically by utilizing the standard kk-ε\varepsilon turbulence model. The diameter ratio in their study was 0.5.

Injectors with sharp-edge orifice inlets operating at higher pressures are susceptible to cavitation and hydraulic flip [10, 34, 43] (Lin and Katz 1987; Bunnell et al 1999; Tafreshi and Pourdeyhimi 2004; Jung et al 2006; Sou et al 2007; Dabiri et al 2007; Park et al 2008). At higher operating pressures, the liquid turns around the sharp edge at a high velocity, leading to a sudden drop in pressure. When the pressure drops below the saturation pressure, the liquid changes into vapor, and vapor bubbles are formed. These vapor bubbles are pushed out of the injector and depending upon the L/DL/D ratio and the operating pressure of the injector, some of the bubbles may transform back into liquid before they leave the injector. However, for small L/DL/D ratios and higher operating pressures, researchers (Jung et al 2006, Dabiri et al 2007, and Park et al 2008) have observed that the bubbles remain in the vapor state throughout the entire length of the orifice (supercavitation). Hydraulic flip occurs when the liquid inside the orifice separates from the wall leading to a reduction in the effective flow area. The ambient fluid can enter the separation zone, which generally extends throughout the length of the orifice (Dabiri et al 2007).

Researchers have investigated turbulent flow and cavitation in liquid injectors numerically by utilizing a variety of CFD techniques. Large Eddy Simulation (LES) has been considered as the most accurate method for predicting turbulent flow in injectors. However, due to the high computational cost associated with LES, a majority of the researchers resorted to RANS-based models, such as the standard kk-ε\varepsilon, RNG (Re-Normalization Group) kk-ε\varepsilon, standard kk-ω\omega, and kk-ω\omega SST (Shear Stress Transport) models. The commonly used cavitation models are the Schnerr-Sauer model and the Zwart–Gerber–Belamri (ZGB) model. Table 1 shows a comprehensive list of turbulence and cavitation models used by several researchers. Since the flow is expected to separate around the sharp-edge orifice inlet, the kk-ω\omega SST model was chosen to model the turbulent flow in the current study because it has been reported to predict separation flows with high accuracy. The ZGB model was utilized to predict cavitation in the injector. The work by Perkovic et al (2008), Sadeegharani et al (2013), Qiu et al (2016), Mithun et al (2018), Bambhania and Patel (2023), Zainab and Syed (2023), Chen et al (2024), and Keller [24] are relevant to the current work due to a similarity in the injector geometry as compared to the injector geometry considered in this work. However, none of the above-mentioned studies included the exact geometry and pressure drops as those considered in the current work.

AuthorTurbulent Model(s)Cavitation Model(s)
Muss et al (2003)Standard kk-ε\varepsilonN/A
Waidmann et al (2006)Standard kk-ε\varepsilonN/A
Aleiferis et al (2007)Standard kk-ε\varepsilon and RNG kk-ε\varepsilonN/A
Tucker et al (2008)LES, Spalart-Allmaras, and kk-ω\omega SSTN/A
Perkovic et al (2008)Standard kk-ε\varepsilonLinear cavitation model
Giannadakis et al (2008)Standard kk-ε\varepsilonDiscrete Bubble Model
Jayashankara and Ganesan (2010)Standard kk-ε\varepsilon and RNG kk-ε\varepsilonN/A
Matsumoto et al (2010)RNG kk-ε\varepsilonN/A
Tsohas and Heister (2011)kk-ω\omega SSTN/A
Guezennec et al (2012)LESN/A
Battistoni and Grimaldi (2012)kk-ζ\zeta-ffTwo-fluid approach
Sadegharani et al (2013)Realizable kk-ε\varepsilonSchnerr-Sauer
Chintala and Subramanian (2013)Standard kk-ε\varepsilonN/A
Benzon et al (2015)RNG kk-ε\varepsilon, standard kk-ω\omega, kk-ω\omega SST, and transition SSTN/A
Tahmasebi et al (2015)kk-ω\omega SSTBarotropic equation of state
Drozda et al (2016)Blended kk-ε\varepsilon and kk-ω\omegaN/A
Qiu et al (2016)Transition SSTZwart–Gerber–Belamri
Bicer and Sou (2016)RNG kk-ε\varepsilonModified Rayleigh
Ghorbani et al (2017)Standard kk-ε\varepsilonSchnerr-Sauer
Hellman (2018)kk-ω\omega SSTN/A
Mithun et al (2018)LESThree-phase model
Shahangian (2020)kk-ω\omega SSTHomogeneous relaxation model
Kim et al (2021)RNG kk-ε\varepsilonN/A
Payri et al (2022)LESN/A
Zainab and Syed (2023)kk-ω\omega SST and LESN/A
Dai et al (2023)Realizable kk-ε\varepsilonZwart–Gerber–Belamri
Bambhania and Patel (2023)RNG kk-ε\varepsilon, Realizable kk-ε\varepsilon, and kk-ω\omega SSTSchnerr-Sauer and Zwart–Gerber–Belamri
Uppu et al (2024)Standard kk-ω\omegaN/A
Keller [24]kk-ω\omega SSTN/A
Chen et al (2024)Transition SSTZwart–Gerber–Belamri
Johnson et al (2025)LESN/A
Gioud et al (2025)LESN/A

Table 1. Literature review of CFD-based turbulent flow and cavitation studies of injectors.

Yuan et al (2025)Standard k−εk-\varepsilonSchnerr-Sauer
Villagomez-Moreno et al (2025)RNG k−εk-\varepsilonZwart–Gerber–Belamri
Li et al (2025)LES, Lattice Boltzmann methodDiscrete Bubble Model
Xi et al (2025)LESModified Schnerr-Sauer

Table 5.

The objective of the current work was to utilize CFD studies to investigate cavitation and turbulent flow for water flowing through the injector with sharp-edged and chamfered orifice inlets for L/D=2L/D = 2, 5, and 10. This work also evaluates the validity of the hypothesis made by Kiaoulias et al (2019) that for a sharp-edged orifice inlet, larger pressure drops (Δp>0.2\Delta p > 0.2 MPa) lead to a hydraulic flip, especially for L/DL/D ratios of 2 and 5.

In the following sections, we describe CFD studies that were performed to predict the flow rate of water and cavitation in a single-liquid injector with sharp-edged and chamfered orifice inlets for various length-to-diameter ratios and pressure drops. A comparison was made between the flow rates observed in experiments by Kiaoulias et al (2019) and the flow rates predicted by the current CFD simulations. Further, plots of volume fraction of liquid water are presented for all the cases, and they were examined to evaluate the cavitation regimes.

Methods

Injector Geometry

The geometry of an injector with a sharp-edge orifice inlet studied in the current work is shown in Figure 2. The overall length of the injector element is 63.5 mm. The injector is made up of two passages. The liquid first passes through a broader down comer with an internal diameter of DDC=3.18D_{DC} = 3.18 mm. Subsequently, the liquid passes through a narrower orifice with an internal diameter of D=0.51D = 0.51 mm (diameter ratio of 0.16). The length of the orifice, LL was varied to numerically simulate L/DL/D ratios of 2, 5, and 10. Those L/DL/D ratios were the same as some of of the L/DL/D ratios considered in previous cold-flow experiments (Kiaoulias et al, 2019).

Geometry of a liquid injector with a sharp-edged orifice inlet

Figure 2. Geometry of a liquid injector with a sharp-edged orifice inlet.

Injectors with a chamfered orifice inlet were also considered. The full cone angle for the chamfered inlet was 120∘120^\circ. An L/DL/D ratio of 5 was considered for the chamfered orifice inlet cases.

Governing Equations

A two-dimensional axisymmetric fluid domain was considered. Cylindrical coordinates (rr, θ\theta, zz) were utilized. Then the velocity vector can be written as V⃗=ue^r+we^z\vec{V}=u\hat{e}_r+w\hat{e}_z, where uu is the radial component and ww is the axial component of velocity.

There are three phases in the current problem of flow and cavitation in injectors. These are air, liquid water, and water vapor. The Volume of Fluid (VOF) method was used to model the three-phase flow. The volume fraction of the ithi^{th} phase, αi\alpha_i was calculated by solving the equation

1ρi[∂∂t(αiρi)+∇⋅(αiρiV⃗i)]=Sαi+∑j=1n(m˙ji−m˙ij),(2)\frac{1}{\rho_i}\left[\frac{\partial}{\partial t}(\alpha_i\rho_i)+\nabla\cdot(\alpha_i\rho_i\vec{V}_i)\right]=S_{\alpha_i}+\sum_{j=1}^{n}(\dot{m}_{ji}-\dot{m}_{ij}), \tag*{(2)}

where ρi\rho_i is the density of the ithi^{th} phase, V⃗i\vec{V}_i is the velocity vector for the ithi^{th} phase phase, SαiS_{\alpha_i} is the source term for the ithi^{th} phase, nn is the total number of phases, m˙ji\dot{m}_{ji} is the mass transfer from the jthj^{th} phase to the ithi^{th} phase, and m˙ij\dot{m}_{ij} is the mass transfer from the ithi^{th} phase to the jthj^{th} phase. The volume fractions for all the phases must sum up to 1, i.e.

∑i=1nαi=1.(3)\sum_{i=1}^{n}\alpha_i=1. \tag*{(3)}

Table 2 gives the density and dynamic viscosity of air, liquid water, and water vapor as used in the current study.

FluidDensity (kg/m3^3)Dynamic viscosity (kg/m-s)
Air1.191.81×10−51.81 \times10^{-5}
Liquid water9989.74×10−49.74 \times10^{-4}
Water vapor0.0180.976×10−50.976 \times10^{-5}

Table 2. Physical properties of fluids at 21°C.

Cavitation was simulated by utilizing the Zwart–Gerber–Belamri model (Zwart et al 2004). The mass transfer from liquid water to water vapor through evaporation is

m˙lw−wv=Fvap3αnuc(1−αwv)ρwvRB23(pv−p)ρlw(4)\dot{m}_{lw-wv}=F_{\mathrm{vap}}\frac{3\alpha_{\mathrm{nuc}}(1-\alpha_{wv})\rho_{wv}}{R_B}\sqrt{\frac{2}{3}\frac{(p_v-p)}{\rho_{lw}}} \tag*{(4)}

where FvapF_{\mathrm{vap}} is the evaporation coefficient, αnuc\alpha_{\mathrm{nuc}} is the nucleation site volume fraction, αwv\alpha_{wv} is the volume fraction of the water vapor, ρwv\rho_{wv} is the density of the water vapor, RBR_B is the vapor bubble radius, pvp_v is the vapor pressure of water, and ρlw\rho_{lw} is the density of liquid water. The mass transfer from water vapor to liquid water through condensation is

m˙wv−lw=Fcond3αwvρwvRB23(p−pv)ρlw(5)\dot{m}_{wv-lw}=F_{\mathrm{cond}}\frac{3\alpha_{wv}\rho_{wv}}{R_B}\sqrt{\frac{2}{3}\frac{(p-p_v)}{\rho_{lw}}} \tag*{(5)}

where FcondF_{\mathrm{cond}} is the condensation coefficient. The vapor bubble radius, RBR_B was assumed to be equal to 10−610^{-6} m and the nucleation site volume fraction, αnuc=5×10−4\alpha_{\mathrm{nuc}}=5\times10^{-4}. The evaporation coefficient was set to 50 and the condensation coefficient was set to 0.01.

The RANS approach was utilized to predict the turbulent flow in the injector. The velocity vector can be written as

V⃗=V⃗avg+v⃗′,(6)\vec{V}=\vec{V}_{avg}+\vec{v}^{\prime}, \tag*{(6)}

where V⃗avg\vec{V}_{avg} is the time-averaged part of the velocity vector and v⃗′\vec{v}^{\prime} is the fluctuating part of the velocity vector. RANS equations treating the three phases as a single liquid in the vector form are

ρ∇⋅V⃗avg=0,(7)\rho\nabla\cdot\vec{V}_{avg}=0, \tag*{(7)}
ρ∂V⃗avg∂t+ρV⃗avg⋅∇V⃗avg+∇⋅(ρv⃗′⊗v⃗′)=−∇p+∇⋅μ(∇V⃗avg+(∇V⃗avg)T)+ρg⃗,(8)\rho\frac{\partial\vec{V}_{avg}}{\partial t}+\rho\vec{V}_{avg}\cdot\nabla\vec{V}_{avg}+\nabla\cdot\left(\rho\vec{v}^{\prime}\otimes\vec{v}^{\prime}\right)=-\nabla p+\nabla\cdot\mu\left(\nabla\vec{V}_{avg}+\left(\nabla\vec{V}_{avg}\right)^{\mathrm{T}}\right)+\rho\vec{g}, \tag*{(8)}

where ρ=∑αiρi\rho=\sum\alpha_i\rho_i is the density of the single fluid, ⊗\otimes represents the outer vector product, pp is the static pressure, μ=∑αiμi\mu=\sum\alpha_i\mu_i is the dynamic viscosity of the single liquid, and g⃗\vec{g} is the acceleration due to gravity assumed as g⃗=9.81e^z\vec{g}=9.81\hat{e}_z m/s2^2.

An Eddy Viscosity Model (EVM) [38] is utilized to account for the Reynolds stress R⃗‾=v⃗′⊗v⃗′\overline{\vec{R}} = \vec{v}' \otimes\vec{v}'. EVM leads to two additional unknowns- the turbulence kinetic energy kk and its specific dissipation rate ω\omega. The kk-ω\omega SST model [31] is used to close the RANS-EVM setup.

Numerical Modeling

CFD-based models were created by using a commercial software package (ANSYS Fluent). The two-dimensional axisymmetric fluid domain and boundary conditions for the sharp-edge orifice inlet cases are shown in Figure 3. Similar fluid domain and boundary conditions were used for the chamfered orifice inlet cases. A pressure inlet was specified at the inlet of the downcomer. The outlet of the fluid domain was modeled as a pressure outlet with p=patm=101.325p = p_{atm} = 101.325 kPa. The remaining boundaries were treated as walls with a no-slip boundary condition. The 5 mm length of the domain from the orifice exit to the outlet was chosen to ensure a sufficiently large downstream zone (∼10D\sim10D) to minimize the impact of any backflow at the outlet on the numerical prediction of the overall flow.

Fluid domain and boundary conditions

Figure 3. Fluid domain and boundary conditions.

Figs. 4 and 5 show the meshes, which consisted of structured quadrilateral elements in the boundary layer region and unstructured triangular elements elsewhere.

Mesh for the sharp-edge orifice inlet with $L/D = 5$

Figure 4. Mesh for the sharp-edge orifice inlet with L/D=5L/D = 5.

Mesh for the chamfered orifice inlet with $L/D = 5$

Figure 5. Mesh for the chamfered orifice inlet with L/D=5L/D = 5.

The y+y^{+} values were kept below 1. The total number of mesh elements for a sharp-edged orifice inlet with L/D=5L/D = 5 was 81,776. The total number of mesh elements for a chamfered orifice inlet with L/D=5L/D = 5 was 86,334. A second-order upwind scheme was used for momentum, volume fraction, vaporization mass, turbulent kinetic energy, and specific rate of dissipation. The Semi-Implicit Method for Pressure Linked Equations-Consistent (SIMPLEC) algorithm was used for the pressure-velocity coupling. The PREssure STaggering Option (PRESTO) scheme was used for the interpolation of pressure. Time integration was performed by utilizing a second-order implicit scheme. A time step of 3×10−83 \times10^{-8} s was used. This resulted in a Courant-Friedrichs-Lewy (CFL) number of 0.14 for the sharp-edged orifice inlet with the largest pressure drop of 0.59 MPa as considered in the current study. A mesh refinement study was carried out for the sharp-edge orifice inlet with L/D=5L/D = 5 for Δp=0.59\Delta p = 0.59 MPa. Table 3 shows the number of mesh elements, volumetric flow rate, and % difference for the mesh refinement study. The % difference shown in Table 3 was calculated by considering the base mesh (81,776 elements) as the reference. The % difference in the flow rate was less than 2% when the mesh was refined from 81,776 elements to 125,109 elements. Therefore, the mesh with 81,776 elements was selected for the current CFD study.

Number of Mesh ElementsQCFDQ_{CFD} (cc/min)% Difference
50,618289.75.9%
81,776273.5
125,109276.51.1%

Table 3. Mesh refinement study for the sharp-edge orifice inlet with L/D=5L/D = 5 for Δp=0.59\Delta p = 0.59 MPa.

Results and Discussion

Volumetric flow rates for the sharp-edged and chamfered orifice inlets

Figure 6 shows plots that compare the CFD predicted volumetric flow rate with the experimentally measured volumetric flow rate (Kiaoulias et al 2019) for different pressure drops across the injector for sharp-edged and chamfered orifice inlets with L/D=5L/D = 5. Based upon Figure 6, the CFD predictions match well with the experimental results for different pressure drops below 0.2 MPa. The CFD model slightly overestimates the volumetric flow rate above 0.2 MPa, with a peak error of 15% for sharp-edged and 9% for chamfered orifice inlets. This may be attributed to the cavitation model for higher flows. It can be concluded that the current CFD models have been validated against experimental measurements by Kiaoulias et al (2019).

Comparison of CFD-predicted and experimentally measured volumetric flow rates for sharp-edge and chamfered orifice inlets

Figure 6. Comparison of CFD-predicted and experimentally measured (Kiaoulias et al 2019) volumetric flow rates for different pressure drops for (a) sharp-edge orifice inlet and (b) chamfered orifice inlet with L/D=5L/D = 5.

Cavitation results for the sharp-edged and chamfered orifice inlets

The plots of volume fraction of the liquid water phase for the sharp-edged orifice inlet cases are presented in Figure 7. No cavitation was observed from the CFD simulations for Δp=0.09\Delta p = 0.09 MPa. For Δp=0.2\Delta p = 0.2 MPa, a cavitation inception was seen close to the sharp edge. As Δp\Delta p was increased to 0.36 MPa, cavitation became stronger, and the cavitation zone extended to around 80% of the orifice length. For Δp=0.48\Delta p = 0.48 MPa and Δp=0.59\Delta p = 0.59 MPa, the cavitation zone extends further downstream inside the orifice, demonstrating very strong cavitation. A hydraulic flip was observed for Δp=0.59\Delta p = 0.59 MPa. Air can be seen to enter upstream at the orifice exit for that case. Kiaoulias et al (2019) stipulated the presence of a hydraulic flip for all pressure drops larger than 0.2 MPa. Although the current CFD study did not reveal a hydraulic flip for Δp=0.36\Delta p = 0.36 MPa and Δp=0.48\Delta p = 0.48 MPa, the current trend of cavitation becoming stronger with an increase in pressure drop and the presence of a hydraulic flip for Δp=0.59\Delta p = 0.59 MPa are consistent with the findings from the experimental study by Kiaoulias et al (2019).

Contours of water liquid volume fraction for the sharp-edged orifice inlet, with panels (a)–(e), cavitation inception and hydraulic flip annotations, and a liquid-water volume-fraction color scale

Figure 7. Contours of water (liquid) volume fraction for the sharp-edged orifice inlet and L/D=5L/D = 5 and with (a) Δp=0.09\Delta p = 0.09 MPa (b) Δp=0.2\Delta p = 0.2 MPa (c) Δp=0.36\Delta p = 0.36 MPa (d) Δp=0.48\Delta p = 0.48 MPa, and (e) Δp=0.59\Delta p = 0.59 MPa.

Figure 8 shows the plots of liquid water volume fraction for the chamfered orifice inlet cases.

Contours of water (liquid) volume fraction for the chamfered orifice inlet, showing cavitation inception and volume fraction for liquid water

Figure 8. Contours of water (liquid) volume fraction for the chamfered orifice inlet and L/D=5L/D = 5 and with (a) Δp=0.07\Delta p = 0.07 MPa (b) Δp=0.14\Delta p = 0.14 MPa (c) Δp=0.21\Delta p = 0.21 MPa (d) Δp=0.27\Delta p = 0.27 MPa, and (e) Δp=0.34\Delta p = 0.34 MPa.

No cavitation was observed for the pressure drops Δp=0.07\Delta p = 0.07 MPa and 0.140.14 MPa. However,

cavitation inception was seen for the pressure drops Δp=0.21\Delta p = 0.21 MPa, 0.270.27 MPa, and 0.340.34 MPa. Overall, no hydraulic flip was observed for the chamfered orifice inlet cases. This is consistent with the findings from the experimental study by Kiaoulias et al (2019).

Flow and cavitation results for the sharp-edge orifice inlet with L/D=2L/D = 2, 5, and 10 for Δp=0.59\Delta p = 0.59 MPa.

Table 4 compares the flow rates predicted by the current CFD study with the experimentally measured values by Kiaoulias et al (2019) for the sharp-edged orifice inlet at Δp=0.59\Delta p = 0.59 MPa and L/D=2L/D = 2, 5, and 10. The CFD-predicted flow rate matched closely with the experimental value for L/D=2L/D = 2 (% difference of −1.3%-1.3\%). The % difference between CFD-predicted and experimental flow rates was 15.2%15.2\% and 11.3%11.3\% for L/D=5L/D = 5 and 10, respectively.

L/DL/DQCFDQ_{\mathrm{CFD}} (cc/min)QExptQ_{\mathrm{Expt}} (cc/min)% Difference
2234.5237.5−1.3%-1.3\%
5273.5237.515.2
10264.5237.511.3%11.3\%

Table 4. CFD-predicted and experimental (Kiaoulias et al (2019)) flow rates for the sharp-edge orifice inlet with L/D=2L/D = 2, 5, and 10 for Δp=0.59\Delta p = 0.59 MPa.

Figure 9 shows the plots of liquid water volume fraction for the L/D=2L/D = 2, 5, and 10 cases. A significant cavitation was observed for L/D=2L/D = 2. However, a hydraulic flip, as postulated by Kiaoulias et al (2019) for the sharp-edged orifice inlet for L/D=2L/D = 2, was not observed from the

Contours of water liquid volume fraction for the sharp-edge orifice inlet with L/D = 2, 5, and 10

Figure 9. Contours of water (liquid) volume fraction for the sharp-edge orifice inlet with L/D=2L/D = 2, 5, and 10 for Δp=0.59\Delta p = 0.59 MPa.

current CFD study. As mentioned in the section 3.2, a hydraulic flip was seen for L/D=5L/D = 5 and that was consistent with the findings by Kiaoulias et al (2019). For L/D=10L/D = 10, the cavitation zone extended to almost the entire orifice length, and a hydraulic flip was not observed. This is consistent with the hypothesis made by Kiaoulias et al (2019).

Conclusion

CFD simulations were carried out to predict the flow and cavitation in single-liquid injectors with sharp-edged and chamfered orifice inlets. The CFD-predicted volumetric flow rate was compared with the experimental values from previous work by Kiaoulias et al (2019). The CFD-predicted flow rate matched well with the experimental values for pressure drops lower than 0.2 MPa. For pressure drops larger than 0.2 MPa, the current CFD models overpredicted the flow rate with a peak % difference of 15% for the sharp-edged cases and a peak % difference of 9% for the chamfered cases. In summary, the flow prediction from the CFD model was validated against the previously published experimental values. Strong cavitation was observed for the sharp-edge orifice inlet with L/D=5L/D = 5 at pressure drops larger than 0.2 MPa. Moreover, a hydraulic flip was observed for a pressure drop of 0.59 MPa. Cavitation inception was observed for the chamfered orifice inlet with L/D=5L/D = 5 at pressure drops larger than 0.2 MPa. The cavitation results for the sharp-edged and chamfered orifice inlets for L/D=5L/D = 5 were found to be consistent with the findings from the experimental study by Kiaoulias et al (2019). The L/DL/D of 2 and 10 were also simulated using the current CFD model. Although a significant cavitation was observed for these L/DL/D, no hydraulic flip was observed. This observation for L/D=2L/D = 2 was not consistent with the findings by Kiaoulias et al (2019). However, the CFD-based prediction of no hydraulic flip for L/D=10L/D = 10 agreed with the findings by Kiaoulias et al (2019).

Acknowledgement

This research was partially supported by Tier 1 Research Awards (ICDS_READ26_l1skg5951 and ICDS_READ26_l2skg5951) from the Institute for Computational and Data Sciences (ICDS) at The Pennsylvania State University. The authors are grateful to the ICDS for providing access to the Roar Collab Cluster. The authors acknowledge Dr. Grant Risha at Penn State Altoona for his consultation.

Conflict of Interest

Authors have no conflicts to report.

ORCID iD

Shreyash Gulati 0000-0001-6089-1421

References

  1. [10]Chew T J C 1973 Hydraulic flip behavior in typical liquid rocket operating regimes AFRPL Rept. AFRPL-TR-72-127 1973.DOI
  2. [23]Kaushik V V R, Ghosh S, Das G and Das P K 2012 CFD simulation of core annular flow through sudden contraction and expansion J. Pet. Sci. Eng. 86-87 153–164. https://doi.org/10.1016/j.petrol.2012.03.003
  3. [24]Keller A 2024 Enhanced liquid rocket injection enabled by additive manufacturing Ph.D. Thesis University of California Los Angeles.
  4. [31]Menter F R 1994 Two-equation eddy-viscosity turbulence models for engineering applications AIAA J. 32(8) 1598-1605. https://doi.org/10.2514/3.12149
  5. [34]Nurick W H 1976 Orifice Cavitation and Its Effect on Spray Mixing J. Fluids Eng. 98(4) 681-687. https://doi.org/10.1115/1.3448452
  6. [38]Pope S 2000 Turbulent Flows Cambridge University Press.DOI
  7. [43]Schmidt D P 1997 Cavitation in diesel fuel injector nozzles Ph.D. Thesis. https://www.proquest.com/docview/304379033?fromopenview=true&pq-origsite=gscholar&sourcetype=Dissertations%20&%20Theses

Paper details

vlnc:W_5ayvfbty
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 4

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents