Modelling the photocatalytic oxidation of methane and other air pollutants for applications in ventilation systems

Abstract

Photocatalytic oxidation (PCO) is a promising strategy for indoor air purification and outdoor pollutant abatement, potentially offering treatment for climate- and health-relevant pollutants such as methane (CH4_4), nitrogen oxides (NOx_\text{x}) and volatile organic compounds (VOCs). In this work, we present experiments evaluating the PCO of CH4_4 (2 to 10 ppm) under varying UV-C light intensities (4 to 59 W/m2^2), using titanium dioxide (TiO2_2) as the photocatalyst. At 2 ppm CH4_4, TiO2_2 achieves a maximum conversion efficiency of 24.4% and a maximum apparent quantum yield of 0.0130.013% over the tested UV-C light intensities, demonstrating activity at environmentally relevant concentrations. We develop a model to interpret the experimental results and assess the potential of PCO for ventilation applications. The model is validated against our CH4_4 data and literature results for formaldehyde (HCHO) and NOx_\text{x}. While laboratory-scale configurations achieve high conversions (e.g., 24.4% for CH4_4), ventilation-scale performance is predicted to be limited by thin concentration boundary layers and short residence times, with conversion efficiencies dropping to around 0.0170.017%. Finally, we estimate the climate impact of CH4_4 removal in terms of CO2_2e emission rates, demonstrating that TiO2_2-based PCO in ventilation applications can yield a net climate benefit (i.e., a net-negative CO2_2e emissions rate) when the modelled CO2_2e removal rate exceeds the emissions from catalyst material production and UV operation, particularly when pre-existing UV-C irradiation is leveraged.

Introduction

Air pollution is among the leading environmental and health risks worldwide, contributing significantly to respiratory disease, cardiovascular morbidity and premature mortality [1, 2, 3]. While outdoor air pollution has historically drawn more attention, due in part to its connection with climate change [4, 5], recent studies highlight that indoor air quality can be equally hazardous, especially as people now spend over 90% of their time indoors, in homes, workplaces, schools and transport systems [6]. This shift places indoor air quality at the forefront of public health and building design. Indoor environments can be polluted with volatile organic compounds (VOCs), nitrogen oxides (NOx_x), ozone (O3_3), methane (CH4_4) and nitrous oxide (N2_2O), originating from building materials, cleaning products, combustion sources and infiltration from outdoor air [1, 2]. Some of these pollutants are harmful at parts-per-billion levels and have been linked to long-term health effects, including asthma, neurotoxicity and cancer. Outdoor air, meanwhile, contains mixtures of anthropogenic and biogenic species. CH4_4 and N2_2O are potent greenhouse gases (GHGs) with global warming potentials (GWPs) many times greater than carbon dioxide (CO2_2) [4, 7]. NOx_x and VOCs serve as precursors to secondary pollutants, including tropospheric O3_3 and fine particulate matter (PM) [8, 9]. Despite regulatory efforts, progress in reducing emissions of these pollutants from sources (e.g., vehicles, industry, agriculture) has been slow. To address these diffuse emissions, there is interest in integrating removal technologies (e.g., catalysts) into built environments that experience substantial airflow (e.g., building exteriors, ventilation systems), as part of a distributed approach to air-quality management [10, 11, 12].

Photocatalytic oxidation (PCO) has emerged as a potentially low-energy and scalable strategy to degrade air pollutants [13, 14]. In these systems, a photocatalyst, typically titanium dioxide (TiO2_2), is irradiated with UV or visible light, generating reactive oxygen species such as hydroxyl radicals (OH·) and superoxide anions (O2−_2^-) [6]. These reactive oxygen species can oxidise adsorbed pollutants into less harmful or less radiatively active products, without requiring chemical reagents or frequent replacement. PCO technologies have been explored in diverse applications, including building exteriors and indoor air purifiers [12, 15, 16, 17]. Their promise lies in continuous pollutant degradation under natural or artificial illumination. However, widespread adoption remains limited by uncertainties in performance under realistic conditions, where pollutant levels are low, airflows are complex and operational constraints such as humidity and light intensity vary [14, 15]. Beyond catalyst material selection and operating conditions, the overall feasibility of pollutant-removal technologies also depends on fabrication, installation and energy inputs, all of which influence the net climate impact of deployed systems.

The performance of PCO has been shown to be sensitive to operating conditions [6, 13, 14, 15, 17], including air pollutant concentration, light intensity, humidity, catalyst properties and flow rate. Bridging the gap between laboratory-scale performance and effectiveness in application will require models that incorporate both reaction kinetics and mass transport and are validated against multiple experimental measurements for different air pollutants. It is critical to distinguish between reaction-limited and mass-transfer-limited regimes [13, 14], which can exhibit similar behaviour but require different design strategies (e.g., improving catalyst activity in the former, or enhancing flow conditions in the latter). Overly simplified models may obscure these distinctions, whereas over-parameterised models or complicated numerical simulations can lack physical interpretability and may not readily support optimisation.

Recent theoretical and experimental studies have begun to address some of these issues [6, 13, 14, 15, 17]. Zhang et al. [13] developed a model coupling the Navier–Stokes equations, advection–diffusion transport and a Langmuir–Hinshelwood kinetic model, to predict NOx_x removal using UiO-66-NH2_2 across varying light intensities, pollutant concentrations and humidity levels. Timmerhuis et al. [14] investigated the role of the Péclet and Damköhler numbers in characterising Bisphenol A removal via TiO2_2, demonstrating that neglecting mass transport can lead to errors in rate constant predictions. Malay eri et al. [6] reviewed reactor configurations and photocatalysts for VOC removal, highlighting the role of catalyst exposure, photon-flux distribution and boundary-layer effects in system performance. Yu et al. [15] investigated a Trombe-wall PCO system for formaldehyde (HCHO) removal using a TiO2_2-coated ceramic and developed a kinetic model accounting for UV intensity, temperature, humidity and concentration. Ballari et al. [17] combined experimental and theoretical studies of NOx_x removal using TiO2_2-coated concrete pavers and used a Langmuir–Hinshelwood kinetic model to capture the effects of irradiance, humidity and flow conditions. Collectively, these studies highlight the variety of operational conditions and the effectiveness of PCO systems at laboratory scale.

Russell et al. [16] conclude that deployments of TiO2_2 coatings in outdoor applications typically yield ambient pollutant concentration reductions of around 2% in the immediate vicinity of treated surfaces. In addition, formation of secondary species has been observed in some studies, such that air-quality impacts depend on surface reactivity and atmospheric chemistry. Cost analyses suggest that using photocatalytic oxidation for atmospheric CH4_4 removal is prohibitively expensive due to the high flow rates required for effective removal [10, 18, ?]. Further analysis shows that targeting higher-concentration CH4_4 sources can yield meaningful climate benefits at source concentrations above 10 ppm, with cost-effective operation using current technologies requiring concentrations above 10310^3 ppm [20]. Chlorine and OH⋅\cdot radicals can oxidise CH4_4 in the gas phase, and laboratory photochemical systems have reported relatively low energy inputs for low-concentration pollutant removal [10, 21]. Photochemical destruction approaches have also been investigated for N2_2O and fluorinated anaesthetic gases in exhaust streams [22].

Building on these foundations, the present study combines modelling and experiments to assess the performance of PCO systems for ventilation applications. We conduct CH4_4-oxidation experiments under varying UV-C light intensities at environmentally relevant CH4_4 concentrations for indoor and outdoor air. These measurements inform the development of a model, solved using asymptotic and numerical methods, that couples non-linear Langmuir–Hinshelwood kinetics with advection–diffusion transport under UV-C illumination. We validate the model using our CH4_4 experimental data, as well as literature data for NOx_x and HCHO oxidation using TiO2_2, over a range of flow rates, concentrations and light intensities. The model allows us to quantify the extent to which laboratory- and application-scale PCO systems are constrained by concentrations, boundary-layer thickness, residence time and geometry. We estimate the potential removal rates and the associated CO2_2e emissions rates for the PCO of CH4_4, enabling assessment of PCO performance under realistic operating conditions and providing a framework for the design and optimisation of potential air-purification technologies.

The rest of the paper is organised as follows. In Section 2, we describe the experimental setup and measurements for CH4_4. Section 3 presents the model, discusses the numerical methods and parameter fitting. In Section 4, we present model and experimental results, investigating performance at lab and application scales, and estimating the potential climate benefits of PCO technologies for CH4_4 removal. Section 5 summarises the results and applications of this modelling and measurement framework, and discusses potential future extensions.

Experiments

To evaluate the PCO of CH4_4 at environmentally relevant concentrations (typical of indoor and outdoor air), we designed a set of experiments informed by previous studies on catalyst performance [23, 24]. Comparative data for NOx_x and HCHO are taken from Ballari et al. [17] and Yu et al. [15], respectively, and are discussed further in Section 4.1. Experimental conditions, PCO measurements and the flow–reactor system are described in Section 2.1. Figure 1 shows the experimental setup used to measure CH4_4 conversion efficiency.

Schematic of the laboratory setup, two-dimensional reactor model, and potential ventilation application

Figure 1. (a) Schematic of the laboratory setup used for the PCO experiments, showing the gas delivery system, UV-C illumination, reactor, GC, FID and TCD for CH4\mathrm{CH}_{4} removal over TiO2\mathrm{TiO}_{2}. (b) Two-dimensional reactor model, representing laminar flow with advection, diffusion and reaction at the UV-C illuminated photocatalyst wall. (c) A potential ventilation application of this UV-C pollutant-removal technology and its connection to our laboratory setup.

Experimental setup and conditions

To evaluate the PCO of CH4\mathrm{CH}_{4} at low concentrations relevant to air-purification applications, titanium dioxide (TiO2\mathrm{TiO}_{2}, Titanium (IV) oxide, anatase, nanopowder, <25 nm, 99.7%, trace metals basis, Sigma-Aldrich) was selected as a representative photocatalyst. TiO2\mathrm{TiO}_{2} is widely studied for its strong photocatalytic activity under UV-C illumination [6, 23], making it a suitable benchmark for evaluating CH4\mathrm{CH}_{4} oxidation rates. In addition to PCO performance, the broader climate benefit of PCO systems in potential ventilation applications is quantified by considering the energy consumption of the UV-C illumination and the catalyst’s embodied carbon, as discussed in Section 4.5 and detailed in Appendix B. Practical deployment of PCO systems would be most effective when high photocatalytic activity is combined with low overall carbon intensity.

The PCO experiments were performed using a reactor system designed to evaluate CH4\mathrm{CH}_{4} removal at environmentally relevant concentrations under UV-C irradiation (see Figure 1). For each experiment, 2 g of TiO2\mathrm{TiO}_{2} was deposited as a thin layer covering the bottom surface of the cylindrical reactor (38 cm total height, 6 cm diameter) and irradiated by a UV-C lamp delivering light intensities between 4 and 59 W/m2\mathrm{W}/\mathrm{m}^{2} on the catalyst surface. The 2D geometry adopted in the model (Section 3) is an idealisation of this configuration, with the centreline height (1 cm) chosen to preserve the residence time of the experimental setup. CH4\mathrm{CH}_{4} and O2\mathrm{O}_{2} served as the active reactants, with N2\mathrm{N}_2 the carrier gas. Gas flows were regulated using mass flow controllers (MFCs), with the total volumetric flow rate maintained at 100 mL/min for all experiments. This value falls within the range of flow rates reported for dilute methane abatement systems in recent literature [25]. Input CH4\mathrm{CH}_4 concentrations ranged from 2 to 10 ppm, reflecting environmentally relevant levels for indoor and outdoor air. Experiments were conducted at ambient temperature (20 °C) under dry conditions (no added humidity).

Measurement and performance metrics

Gas-phase products were quantified using an Agilent 8890 gas chromatograph (GC) equipped with a flame ionisation detector (FID) and a thermal conductivity detector (TCD). Peak areas for CH4\mathrm{CH}_4 and CO2\mathrm{CO}_2 were extracted from the chromatograms and converted to concentrations in parts per million (ppm). The CH4\mathrm{CH}_4 conversion efficiency was calculated assuming complete oxidation to CO2\mathrm{CO}_2. This assumption is supported by the absence of additional FID peaks in our chromatograms. The conversion efficiency is given by

η=CCO2CCO2+CCH4,(1)\eta= \frac{C_{\mathrm{CO}_2}}{C_{\mathrm{CO}_2} + C_{\mathrm{CH}_4}}, \tag*{(1)}

where CCH4C_{\mathrm{CH}_4} (CCO2C_{\mathrm{CO}_2}) is the concentration of CH4\mathrm{CH}_4 (CO2\mathrm{CO}_2). This stoichiometric approach provides a measure of CH4\mathrm{CH}_4-degradation efficiency under the tested CH4\mathrm{CH}_4 concentrations and light intensities. The apparent quantum yield (AQY) is defined as the ratio of the CH4\mathrm{CH}_4 reaction rate to the incident UV-C photon flux (both in moles/(m2\mathrm{m}^2s)) and is computed for each combination of CH4\mathrm{CH}_4 concentration and light intensity as

AQY=rCH4rPhoton.(2)\mathrm{AQY} = \frac{r_{\mathrm{CH}_4}}{r_{\mathrm{Photon}}}. \tag*{(2)}

In the above, rCH4r_{\mathrm{CH}_4} is determined from the measured CH4\mathrm{CH}_4 conversion efficiency at each CH4\mathrm{CH}_4 concentration and rPhoton=I/(EPhotonNA)r_{\mathrm{Photon}} = I/(E_{\mathrm{Photon}}N_{\mathrm{A}}) is the incident UV-C photon flux (moles/(m2\mathrm{m}^2s)), where II is the incident light intensity (W/m2\mathrm{m}^2), EPhotonE_{\mathrm{Photon}} is the energy of photons (J) and NAN_{\mathrm{A}} is Avogadro’s constant (mol−1^{-1}).

In addition to the surface reaction at the TiO2\mathrm{TiO}_2 catalyst, UV-C irradiation at the wavelengths emitted by our UV-C lamp can photolyse O2\mathrm{O}_2 to generate reactive oxygen species, including OH⋅\mathrm{OH}\cdot, which are capable of oxidising CH4\mathrm{CH}_4 in the bulk [21, 25, 26]. To isolate the catalytic contribution from the bulk reaction and enable comparison with the reactor PCO model (Section 3), a control experiment was performed for each combination of CH4\mathrm{CH}_4 concentration and UV-C light intensity, repeating the measurement with no catalyst present. The conversion efficiency is then defined as

ηexp=ηcat−ηno−cat,(3)\eta^{\mathrm{exp}} = \eta^{\mathrm{cat}} - \eta^{\mathrm{no-cat}}, \tag*{(3)}

where ηcat\eta^{\mathrm{cat}} is the total conversion efficiency measured with catalyst present and ηno−cat\eta^{\mathrm{no-cat}} is the conversion efficiency measured without catalyst present, both evaluated using (1). We use ηexp\eta^{\mathrm{exp}} to characterise catalyst performance and to compute the AQY via (2); these quantities are compared with reactor-model predictions in Section 4.1. A detailed quantification of the total conversion efficiency, including the bulk and surface reactions, as well as a description of the bulk-phase reaction mechanism, is left for future work.

Experimental scope and limitations

A schematic of the PCO setup, including the gas delivery system, UV-C lamp alignment, reactor chamber, GC, FID and TCD analysis configuration, is shown in fig:1a. Table 1 summarises All CH4\mathrm{CH}_{4} experiments were conducted under controlled laboratory conditions using dry gas feeds, clean reactant streams and an idealised reactor geometry. While these conditions allow for reproducible catalyst performance, they do not fully replicate real-world environments, where humidity, contaminants, fluctuating flow and light-intensity profiles may affect the catalyst oxidation state and long-term stability [27, 28]. Accordingly, the reported performance metrics reflect catalytic behaviour under laboratory conditions rather than application environments.

Ballari et al. [17]Yu et al. [15]Present work
Flow and geometric quantities
PollutantNOx\mathrm{NO}_{x}HCHOCH4\mathrm{CH}_{4}
Concentration (ppm)0.11 to 1.090.17 to 0.92 to 10
Centreline height (mm)1.5510
Length (mm)20024060
Flow rate (L/min)3 to 51 to 50.1
Temperature (°C)2015 to 4520
Humidity (%)10 to 8020 to 900
UV-C (W/m2^{2})0.3 to 132.1 to 94 to 59
Fitted constants
Light∗^{*}0.230.380.21
Adsorption∗^{*} (m3^{3}/mol)3.9×10−53.9 \times10^{-5}1.1×10−51.1 \times10^{-5}4.6×10−54.6 \times10^{-5}
Rate∗^{*} (mol·m2(a−1)^{2(a-1)}/(s·Wa^{a}))5.221.480.084
Non-dimensional numbers
Péclet2.50 to 4.172.500.085
Damköhler3.450.26 to 0.460.016 to 0.027
Langmuir0.54 to 5.710.26 to 1.360.17 to 0.84

Table 1. Summary of parameters for each of the PCO studies on CH4\mathrm{CH}_{4}, HCHO and NOx\mathrm{NO}_{x} removal using TiO2_{2}. Quantities marked with an asterisk are fitted to the experimental data. Parameters held fixed across all studies are: catalyst (TiO2_{2}), molecular diffusivity (1.8×10−51.8 \times10^{-5} m2^{2}/s), dynamic viscosity (1.85×10−51.85 \times10^{-5} Pa·s) and pressure (1 atm). the parameters for the CH4\mathrm{CH}_{4} experiments, as well as for HCHO [15] and NOx\mathrm{NO}_{x} [17] PCO systems.

Model

With the PCO experiments for CH4\mathrm{CH}_{4} established in Section 2, we develop a modelling framework to interpret these results and selected literature data for HCHO and NOx\mathrm{NO}_{x} [15, 17]. The modelled domain is outlined in Figure 1. In Section 4.4, we scale these results up to ventilation applications to assess potential climate benefits, as illustrated in Figure 1. We begin by presenting the governing equations and outlining the model assumptions (Section 3.1–3.2). Then, we describe the solution approach, which combines asymptotic methods (Appendix A) and numerical methods (Section 3.3). Finally, we describe the fitting of model parameters to experimental data (Section 3.4).

Governing equations

We model the transport and removal of a gaseous pollutant in a 2D, steady-state, laminar-flow reactor (Figure 1b). The channel has centreline height HH and length LL, with the bottom wall (y=0y = 0) coated with a photocatalyst and uniformly illuminated by UV-C light. We assume that the flow is fully developed in the streamwise direction and incompressible, with a parabolic streamwise velocity profile and negligible wall-normal velocity.

Under these assumptions, the pollutant concentration field, c=c(x,y)c = c(x, y), satisfies the steady advection–diffusion equation:

u∂c∂x=D∂2c∂y2,(4)u \frac{\partial c}{\partial x} = D \frac{\partial^2 c}{\partial y^2}, \tag*{(4)}

where u=u(y)u = u(y) is the velocity profile and DD is the molecular diffusivity. The velocity profile for fully-developed laminar flow between parallel plates is

u=3⟨u⟩2(1−(y−HH)2),(5)u = \frac{3\langle u\rangle}{2}\left(1 - \left(\frac{y-H}{H}\right)^2\right), \tag*{(5)}

where ⟨u⟩\langle u\rangle is the mean streamwise velocity. The pollutant enters the reactor at a uniform concentration cinc_{\mathrm{in}}. The top wall (y=2Hy = 2H) is impermeable, while the bottom wall (y=0y = 0) undergoes photocatalytic reaction. The corresponding boundary conditions are

c(x=0,y)=cin,D∂c∂y(x,0)=r(x),∂c∂y(x,2H)=0,(6)c(x = 0, y) = c_{\mathrm{in}}, \qquad D\frac{\partial c}{\partial y}(x, 0) = r(x), \qquad\frac{\partial c}{\partial y}(x, 2H) = 0, \tag*{(6)}

where we assume, following Zhang et al. [13], that the surface reaction rate r=r(x)r = r(x) follows a light-modulated Langmuir–Hinshelwood expression:

r(x)=k′IaKc(x,0)1+Kc(x,0),(7)r(x) = \frac{k'I^a Kc(x, 0)}{1 + Kc(x, 0)}, \tag*{(7)}

where k′k' is the rate constant (mol·m2(a−1)^{2(a-1)}/(s·Wa^a)), KK is the adsorption equilibrium constant (m3^3/mol), II is the UV irradiance (W/m2^2) and aa is the light-intensity exponent. The conversion efficiency is defined as the reduction in the average pollutant concentration across the channel at the outlet:

ηmodel=1−1cin∫y=02Hc(x=L,y) dy.(8)\eta^{\mathrm{model}} = 1 - \frac{1}{c_{\mathrm{in}}}\int_{y=0}^{2H} c(x = L, y)\,\mathrm{d}y. \tag*{(8)}

The unknown parameters in (7), k′k', KK and aa, are fitted to three experimental datasets, as described in Section 3.4. The model captures both reaction saturation at high pollutant concentrations and a sub-linear dependence on light intensity, as will be observed in the CH4_4 experiments (Section 2).

Non-dimensionalisation

To compare PCO performance across reactors and against results from prior experiments (Section 2; Ballari et al. [17]; Yu et al. {cite:p}`ref-15}), we introduce the non-dimensional variables

x=Hx^,y=Hy^,c=cinc^,u=⟨u⟩u^.(9)x = H\hat{x}, \qquad y = H\hat{y}, \qquad c = c_{\mathrm{in}}\hat{c}, \qquad u = \langle u\rangle\hat{u}. \tag*{(9)}

Substituting (9) into the advection–diffusion equation (4) yields the transport equation

u^∂c^∂x^=1Pe∂2c^∂y^2,(10)\hat{u}\frac{\partial\hat{c}}{\partial\hat{x}} = \frac{1}{\mathrm{Pe}}\frac{\partial^2\hat{c}}{\partial\hat{y}^2}, \tag*{(10)}

where the Péclet number, Pe=⟨u⟩H/D\mathrm{Pe} = \langle u\rangle H/D, quantifies the ratio of advective to diffusive transport. The velocity field (5) becomes

u^=32(1−(y^−1)2).(11)\hat{u} = \frac{3}{2}\left(1-(\hat{y}-1)^2\right). \tag*{(11)}

The boundary conditions (6) become

c^(0,y^)=1,∂c^∂y^(x^,2)=0,∂c^∂y^(x^,0)=Dac^(x^,0)1+βc^(x^,0).(12)\hat{c}(0,\hat{y})=1,\qquad\frac{\partial\hat{c}}{\partial\hat{y}}(\hat{x},2)=0,\qquad\frac{\partial\hat{c}}{\partial\hat{y}}(\hat{x},0)=\frac{\mathrm{Da}\hat{c}(\hat{x},0)}{1+\beta\hat{c}(\hat{x},0)}. \tag*{(12)}

where the Damköhler number, Da=Hk′IaK/D\mathrm{Da}=Hk'I^aK/D, measures the ratio of surface reaction rate to mass transport, and the Langmuir parameter, β=Kcin\beta=Kc_{\mathrm{in}}, quantifies surface saturation at the inlet concentration. The conversion efficiency (8) is given by

ηmodel=1−∫y^=02c^(x^=1,y^) dy^.(13)\eta^{\mathrm{model}}=1-\int_{\hat{y}=0}^{2}\hat{c}(\hat{x}=1,\hat{y})\,\mathrm{d}\hat{y}. \tag*{(13)}

Asymptotic solutions to the governing equations and conversion efficiency (10)–(13) are derived in the limits of strong and weak diffusion (Pe≪1\mathrm{Pe}\ll1, Pe≫1\mathrm{Pe}\gg1), reaction (Da≪1\mathrm{Da}\ll1, Da≫1\mathrm{Da}\gg1) and adsorption (β≪1\beta\ll1, β≫1\beta\gg1) in Appendix A.

Numerical methods

The non-dimensional system of equations, (10)–(12), is solved numerically using MATLAB’s pdepe [29]. The y^\hat{y} domain is discretised using finite differences, and the resulting system is integrated in x^\hat{x} to obtain the concentration field c^\hat{c}. Mesh independence is verified by grid refinement, and standard grid sizes of Nx^=Ny^=100N_{\hat{x}}=N_{\hat{y}}=100 are used for all results in Section 4. The numerical solution is benchmarked against the asymptotic results derived in Appendix A and against literature data from Ballari et al. [17] and Yu et al. [15].

Model fitting to experiments

We compare the PCO of three representative indoor and outdoor pollutants: CH4\mathrm{CH}_4, HCHO and NOx\mathrm{NO}_x, across three experimental datasets, each employing TiO2\mathrm{TiO}_2 as the photocatalyst. These systems differ in geometry, flow rate, pollutant concentration, operating temperature and UV intensity, as summarised in Table 1. Each PCO system is modelled using the 2D advection–diffusion equation for pollutant concentration (4), coupled to a surface reaction following light-modulated Langmuir–Hinshelwood kinetics (6). Kinetic parameters (k′k', KK, aa) are estimated by minimizing the sum of squared errors (SSE) between experimental and modelled removal efficiencies across NN experimental realisations:

SSE⁡(k′,K,a)=∑i=1N(ηiexp−ηimodel(k′,K,a))2.(14)\operatorname{SSE}(k',K,a)=\sum_{i=1}^{N}\left(\eta_i^{\mathrm{exp}}-\eta_i^{\mathrm{model}}(k',K,a)\right)^2. \tag*{(14)}

The PDE system (4)–(6) is solved numerically using MATLAB’s pdepe, and the kinetic parameters are obtained by minimising the SSE using MATLAB’s fmincon [29].

Results

With the CH4\mathrm{CH}_{4} PCO experiments described in Section 2 and the model outlined in Section 3, we compare model and experimental trends across CH4\mathrm{CH}_{4}, NOx\mathrm{NO}_{x} and HCHO (Section 4.1), we compare experimental trends for CH4\mathrm{CH}_{4} with others found in the literature (Section 4.2), we scale trends from laboratory reactors to ventilation systems (Section 4.3–4.4, fig:1b–fig:1c), and we estimate the potential climate benefits of PCO technologies in ventilation systems (Section 4.5). All conversion efficiencies, AQYs, and climate-benefit estimates for CH4\mathrm{CH}_{4} reported in this section characterise only the catalytic contribution, isolated from the bulk reaction through the control experiments described in Section 2; total values, including the bulk reaction, will be characterised in future work.

Pollutant removal under variable conditions

Using the PCO model in Section 3, we simulate the conversion efficiency of CH4\mathrm{CH}_{4}, NOx\mathrm{NO}_{x} and HCHO across a range of inlet concentrations (0.11 to 10 ppm) and UV-C light intensities (0.1 to 59 W/m2\mathrm{W}/\mathrm{m}^{2}), consistent with the experimental conditions (Section 2, [17], [15]). All experiments employ TiO2\mathrm{TiO}_{2} as the photocatalyst, at standard atmospheric pressure, with fixed physical constants (diffusivity, viscosity). The systems differ in chemical properties, reactor design and fitted kinetic parameters (Table 1). CH4\mathrm{CH}_{4} exhibits the highest adsorption constant (K=4.6×10−5 m3/molK = 4.6 \times10^{-5}\ \mathrm{m}^{3}/\mathrm{mol}), while NOx\mathrm{NO}_{x} (3.9×10−5 m3/mol3.9 \times10^{-5}\ \mathrm{m}^{3}/\mathrm{mol}) and HCHO (1.1×10−5 m3/mol1.1 \times10^{-5}\ \mathrm{m}^{3}/\mathrm{mol}) have lower values, reflecting weaker adsorption onto the catalyst surface. NOx\mathrm{NO}_{x} has the highest rate constant (k′=5.22 mol⋅m2(a−1)/(s⋅Wa)k' = 5.22\ \mathrm{mol}\cdot\mathrm{m}^{2(a-1)}/(\mathrm{s}\cdot\mathrm{W}^{a})), followed by HCHO (1.48 mol⋅m2(a−1)/(s⋅Wa)1.48\ \mathrm{mol}\cdot\mathrm{m}^{2(a-1)}/(\mathrm{s}\cdot\mathrm{W}^{a})) and CH4\mathrm{CH}_{4} (0.084 mol⋅m2(a−1)/(s⋅Wa)0.084\ \mathrm{mol}\cdot\mathrm{m}^{2(a-1)}/(\mathrm{s}\cdot\mathrm{W}^{a})), indicating that NOx\mathrm{NO}_{x} reacts most rapidly once adsorbed on the catalyst surface, although a direct comparison is complicated by the units of k′k' depending on aa, which differs across pollutants. Light-intensity exponents vary across experiments (0.23 for NOx\mathrm{NO}_{x}, 0.38 for HCHO, 0.21 for CH4\mathrm{CH}_{4}). Values of a<0.5a < 0.5 indicate that the systems operate in a regime where mass-transport limitation contributes to the photon-utilisation efficiency, in addition to electron–hole recombination losses that are typically associated with a≈0.5a \approx0.5 at moderate-to-high irradiance [6].

For all PCO systems, conversion efficiency decreases non-linearly with concentration due to Langmuir–Hinshelwood kinetics ((7)), with the steepest decline observed for NOx\mathrm{NO}_{x} (fig:2d). CH4\mathrm{CH}_{4} and HCHO show more gradual declines in conversion efficiency due to the combined effects of adsorption and reaction at the catalyst surface (fig:2a, fig:2g). The conversion efficiency increases with light intensity and begins to saturate at high irradiance for CH4\mathrm{CH}_{4} and NOx\mathrm{NO}_{x} (fig:2b, fig:2e). In contrast, HCHO operates at lower light intensities and exhibits less saturation within the investigated range (fig:2h). Agreement between model predictions and experimental data is good across all cases. The asymptotic solutions accurately reproduce the numerical results in their respective regions of validity, providing a closed-form alternative to numerical simulation. Deviations from model predictions may be attributable to low-concentration measurement errors, humidity or flow effects, depending on the specific experimental setup. All experimental realisations are illustrated in non-dimensional Da–Pe space (white symbols in fig:2c, fig:2f, fig:2i), where the magnitudes of Da and Pe place the CH4\mathrm{CH}_{4}, NOx\mathrm{NO}_{x} and HCHO experiments on the boundary between low and high removal. Asymptotic solutions in this region (Appendix A.1) predict where η=10%\eta= 10\% accurately (dashed lines in fig:2c, fig:2f, fig:2i), providing guidance for reactor design to achieve high conversion, i.e., Da≫Pe\mathrm{Da} \gg\mathrm{Pe}.

Apparent quantum yield

To assess PCO performance compared to the literature, we compute the AQY (%) of CH4_4 oxidation across the range of concentrations (2 to 10 ppm) and UV-C light intensities (4 to 59 W/m2^2) considered in Section 4.1. The AQY represents the ratio of reacted CH4_4 molecules to incident photons and quantifies photon utilisation efficiency independently of the experimental setup, whereas η\eta reflects performance for a given experimental setup. For each experiment, AQY was calculated from the measured reaction rate and incident photon flux as described in Section 2.1. We evaluate the AQY for (i) the present experiments, (ii) other recent low-concentration photocatalyst experiments [30] and (iii) the higher-concentration dataset compiled in Tsopelakou et al. [23]. The results are shown in Figure 3.

Apparent quantum yield for CH4 oxidation at varying inlet concentrations and light intensities

Figure 3. Apparent quantum yield (%) for CH4\mathrm{CH_4} oxidation for varying inlet concentrations (ppm) and light intensities (W/m2^2). Symbols denote experimental measurements and solid lines show model predictions using the quantities in Table 1. In the left panel we show low-concentration systems (cin∈[100 ppm,102 ppm]c_{\mathrm{in}} \in[10^{0}\ \mathrm{ppm}, 10^{2}\ \mathrm{ppm}]) and in the right panel we show high-concentration data (cin∈[105 ppm,106 ppm]c_{\mathrm{in}} \in[10^{5}\ \mathrm{ppm}, 10^{6}\ \mathrm{ppm}]) [30, 31, 32, 33, 34, 35, 36, 37, ?, 39, 40, 41, 42, 43].

In the left panel of Figure 3, the AQY increases with increasing CH4\mathrm{CH_4} concentration (4.8×10−34.8 \times10^{-3} to 0.013%0.013\% for 2 to 10 ppm and 4 W/m24\ \mathrm{W/m^2}) and decreases with increasing light intensity (4.8×10−34.8 \times10^{-3} to 4.7×10−4%4.7 \times10^{-4}\% for 2 ppm and 4 to 59 W/m259\ \mathrm{W/m^2}). For the present experiments, the increase with concentration is most pronounced at lower concentrations (<10< 10 ppm), with the AQY approaching a plateau at higher concentrations (>10> 10 ppm). Increasing the light intensity enhances the conversion efficiency (Figure 2) but reduces the AQY, reflecting a sub-linear dependence on light intensity (a=0.21a = 0.21, Table 1). Although higher photon flux accelerates the reaction rate, the reaction rate grows more slowly than the photon supply, resulting in a reduced AQY. At low CH4\mathrm{CH_4} concentrations, the surface coverage is small, so adding more CH4\mathrm{CH_4} molecules substantially increases reaction rates, leading to a steep rise in AQY. As the CH4\mathrm{CH_4} concentration increases further, surface sites approach saturation, and the incremental gain in rate per additional CH4\mathrm{CH_4} molecule diminishes, causing AQY to level off. The model reproduces the trends of the present CH4\mathrm{CH_4}-experimental data in the left panel of Figure 3.

Conversion efficiency plots for CH4, NOx, and HCHO

Figure 2. Conversion efficiency η\eta (%) as a function of (a, d, g) inlet concentration (ppm) and (b, e, h) UV light intensity (W/m2^2), with the corresponding experimental locations in (Da, Pe) space and contours of η\eta from 0% (blue) to 100% (red) shown in (c, f, i). Data correspond to (a–c) CH4_4 (Section 2), (d–f) NOx_x [17], and (g–i) HCHO [15]. Solid lines denote numerical solutions of the advection–diffusion equation with Langmuir–Hinshelwood kinetics (4)–(6), while dashed lines indicate asymptotic solutions in the small-Pe (18) and large-Pe limits (43).

Concentration field in the reactor

To examine pollutant transport in the different PCO reactors, we compute steady-state 2D concentration fields for CH4\mathrm{CH_4}, NOx\mathrm{NO_x} and HCHO. Pollutant transport occurs predominantly via advection in the streamwise direction and diffusion in the wall-normal direction, with photocatalytic reaction at the bottom surface (y=0y = 0) and a no-flux condition at the top surface (y=2Hy = 2H). Figure 4 shows the concentration field for CH4\mathrm{CH_4} (panel a), NOx\mathrm{NO_x} (b) and HCHO (c) under maximum removal conditions, as identified in Figure 2. The streamwise concentration gradients result from the combined effects of surface kinetics, flow rate, light intensity and pollutant adsorption.

Contours of the concentration field for maximum removal in the laboratory-scale system

Figure 4. Contours of the concentration field c(x,y)c(x, y) for maximum removal in the laboratory-scale system. (a) CH₄ (Da = 0.027, Pe = 0.085 and β\beta = 0.17; Section 2), (b) NOₓ (Da = 3.45, Pe = 2.50 and β\beta = 0.54; Ballari et al. [17]) and (c) HCHO (Da = 0.46, Pe = 2.50 and β\beta = 0.26; Yu et al. [15]). The inset shows the location in (Da, Pe)-space and contours of η\eta from 0% (blue) to 100% (red). Solid lines represent the numerical solution of the model (4)–(6), while dashed lines indicate the asymptotic solution in the small-Pe limit (18).

The CH4\mathrm{CH_4} and HCHO systems exhibit approximately linear concentration profiles along xx (fig:4a,c) with weak axial gradients. This is consistent with Da/Pe≪1\mathrm{Da/Pe} \ll1, for which the concentration varies slowly along the reactor and the influence of Langmuir–Hinshelwood nonlinearity (through β\beta) is negligible. In contrast, the NOₓ system shows a sharper inlet decrease followed by slight downstream flattening (Figure 4b), consistent with Da/Pe = O(1)O(1). In this regime, adsorption effects (through β\beta) begin to influence the kinetics, leading to the observed curvature. In all cases, Pe ≪1\ll1, and cross-channel concentration gradients remain weak, indicating that transverse diffusion is sufficiently rapid to maintain near-uniformity in yy and strong coupling between reaction and cross-channel mass transport.

Concentration field in ventilation applications

To evaluate the scalability of PCO for indoor air treatment, we extend the laboratory-scale model from Section 3 to a duct geometry representative of ventilation systems. The duct is assumed to have a rectangular cross-section with a height of 0.2 m, a width of 0.2 m and a 1 m long test section, uniformly illuminated with UV-C light. Air flows at a rate of 0.08 m³/s, corresponding to an average velocity of approximately 2 m/s. These operating conditions enhance advective transport and reduce residence time relative to the laboratory-scale setup, resulting in elevated Reynolds numbers and the formation of a concentration boundary layer near the catalyst surface. We assume that the bottom wall of the duct is coated with TiO₂, while other walls are treated as no-flux boundaries.

Figure 5 presents the simulated concentration fields in the duct under the high-removal conditions identified in Figure 2. In contrast to the laboratory reactor (Figure 4), the duct-scale concentration field exhibits steep wall-normal gradients near the catalyst, while concentrations remain nearly uniform outside the boundary layer, indicating that the system is mass-transfer-limited. Under these conditions, removal efficiencies are low: 0.010% to 0.017% for CH4\mathrm{CH}_4, 0.56% for NOx\mathrm{NO}_x and 0.039% to 0.070% for HCHO. Table 2 summarises these results, showing the estimated mass removed for CH4\mathrm{CH}_4, NOx\mathrm{NO}_x and HCHO, together with the associated experimental parameters from Section 2, Ballari et al. [17] and Yu et al. [15]. The annual removal for the assumed test section is modest, ranging from 2.1×10−72.1 \times10^{-7} to 2.9×10−52.9 \times10^{-5} tonnes per pollutant per year across CH4\mathrm{CH}_4, NOx\mathrm{NO}_x and HCHO, illustrating the large surface area required to achieve large removal rates in ventilation systems [11].

Contours of the concentration field for maximum removal in the duct-scale system

Figure 5. Contours of the concentration field c(x,y)c(x,y) for maximum removal in the duct-scale system. (a) CH4\mathrm{CH}_4 (Da = 0.090, Pe = 1×1041 \times10^{4} and β\beta = 0.17; Section 2), (b) NOx\mathrm{NO}_x (Da = 3.46, Pe = 2×1042 \times10^{4} and β\beta = 0.57; Ballari et al. [17]) and (c) HCHO (Da = 0.39, Pe = 2×1042 \times10^{4} and β\beta = 0.26; Yu et al. [15]). The inset shows the location in (Da, Pe)-space and contours of η\eta from 0% (blue) to 100% (red). Solid lines represent the numerical solution of the model (4)–(6), while dashed lines indicate the asymptotic solution in the large-Pe limit (43).

ParameterBallari et al. (2010)Yu et al. (2017)Present
Removal quantities
Concentration (ppm)0.11 to 1.090.17 to 0.92 to 10
Removal efficiency (%)0.55650.0389 to 0.07020.0095 to 0.0165
Max. removal rate (×10−3\times10^{-3} ppm/s)0.612 to 6.070.066 to 0.6320.190 to 8.25
Max. mass removed (×10−5\times10^{-5} t/y)0.290 to 2.880.021 to 0.1960.031 to 1.36
Climate benefit for UV light
CO2_2e removal rate (×10−3\times10^{-3} tCO2_2e/y)––0.026 to 1.14
Net CO2_2e w/ UV (×10−2\times10^{-2} tCO2_2e/y)––4.27 to 4.38
Net CO2_2e w/o UV (×10−3\times10^{-3} tCO2_2e/y)––−1.13 to −0.014

Table 2. Summary of the predicted removal rates and climate benefit metrics for scaling up photocatalytic studies on CH4_4, HCHO and NOx_x removal using TiO2_2 to a ventilation system of height 0.2 m, width 0.2 m and 1 m length. The flow rate is 0.08 m3^3/s and the UV-C lamp is 25 W, which provides the range of light intensities in the laboratory experiments.

Climate benefit for UV light in ventilation applications

The PCO system described in Section 4.4 relies on UV-C irradiation to activate TiO2_2 surfaces and oxidise CH4\mathrm{CH}_4. This approach achieves high CH4\mathrm{CH}_4 conversion (Section 4.1); however, it requires electrical energy for UV illumination, resulting in associated CO2_2e emissions. In addition, the embodied carbon of the TiO2_2 catalyst contributes to the climate impact and must be included in the assessment [44]. The use of metal-free TiO2_2 results in lower embodied carbon compared to metal-loaded catalysts [24]. The net climate impact of CH4\mathrm{CH}_4 PCO is assessed for a duct-scale system using the methodology detailed in Appendix B. Note that the catalytic performance reported here represents short-term activity under controlled laboratory conditions. The net CO2_2e emissions analysis assumes stable catalyst performance and does not account for potential deactivation or replacement requirements. Evaluation of catalyst durability, structural evolution and lifetime performance in realistic environments is therefore an important direction for future work.

Each system is assumed to operate with a 25 W UV lamp, which we assume provides the maximum irradiance over the catalyst surface, running continuously 24 h/day throughout the year (see Table 3). Under these operating conditions, the system consumes around 219 kWh/y of electrical energy, corresponding to 0.044 tCO2_2/y of emissions for a grid electricity intensity of 200 gCO2_2/kWh. The embodied carbon of the catalyst is based on a TiO2_2 mass of 3.2 g and an emission factor of 4 gCO2_2e/gTiO2_2 [44]. Assuming an annual replacement cycle for the catalyst (an upper-bound assumption pending lifetime studies), this yields an annual contribution of 1.3 ×10−5\times10^{-5} tCO2_2e/y. The pollutant removal efficiency from Section 4.4 was applied to the inlet concentration to calculate the pollutant removal per unit volume, which was then converted to a removal rate using the ventilation flow rate, as summarised in Table 2. Under the specified operating conditions, the system is predicted to remove approximately 3.1 ×10−7\times10^{-7} to 1.4 ×10−5\times10^{-5} tCH4_4/y. Considering the 20-year global warming potential of CH4_4 (GWP20_{20} = 84 [4]), the annual CH4_4 removal corresponds to a climate benefit of approximately 2.6 ×10−5\times10^{-5} to 1.1 ×10−3\times10^{-3} tCO2_2e/y. When the CO2_2e emissions from UV electricity consumption and catalyst embodied carbon are included, the net climate effect is predicted to be a net positive emission of approximately 4.3 ×10−2\times10^{-2} to 4.4 ×10−2\times10^{-2} tCO2_2e/y, indicating that the energy cost of UV operation outweighs the climate benefit of CH4_4 removal in this configuration. However, if the UV energy is assumed to be already available (e.g., in a pre-existing disinfection systems), the net climate effect is predicted to be approximately −1.1 ×10−3\times10^{-3} to −1.4 ×10−5\times10^{-5} tCO2_2e/y, indicating that the system would be effectively removing CO2_2e. Overall, this calculation demonstrates that duct-scale TiO2_2-based PCO may provide a measurable net climate benefit when leveraging pre-existing UV irradiation, even when accounting for catalyst embodied carbon.

ParameterValue
Catalyst materialTiO2_2
Catalyst area (ventilation panel)0.04 m20.04\ \mathrm{m}^2
UV lamp power25 W25\ \mathrm{W}
Operation time24 h/day, 365 days/y24\ \mathrm{h/day},\ 365\ \mathrm{days/y}
Electricity CO2_2 intensity200 gCO2/kWh200\ \mathrm{gCO}_2/\mathrm{kWh}
Catalyst lifetime1 year1\ \mathrm{year}
TiO2_2 emission factor4 gCO2e/gTiO24\ \mathrm{gCO}_2\mathrm{e}/\mathrm{gTiO}_2
Catalyst mass3.2 g3.2\ \mathrm{g}

Table 3. Parameters used in the life-cycle assessment of TiO2_2-based PCO of CH4_4, including catalyst properties, UV energy demand and emissions factors [4, 44, 48, 49, 50, 51].

Discussion

The modelling framework developed here provides a description of PCO for CH4_4, NOx_x and HCHO. Comparison of the model with our CH4_4 experiments and literature data for NOx_x and HCHO (Figure 2) shows that the fitted kinetic parameters, the rate coefficient k′k', adsorption constant KK and light exponent aa, reproduce measured removal efficiencies and differentiate pollutants with fast surface kinetics from those limited by weak adsorption. For CH4\mathrm{CH}_4, strong adsorption increases surface coverage and yields high conversion despite slower surface kinetics. In contrast, NOx\mathrm{NO}_x oxidation is governed by faster surface kinetics even though adsorption is weaker. HCHO exhibits the lowest activity because its adsorption constant and rate coefficient are small, resulting in limited surface coverage and slow reaction. These differences explain the pollutant-specific removal trends predicted by the model and show how surface coverage and saturation constrain PCO performance at environmentally relevant concentrations. Extending the lab-scale results [15, 17] to duct geometries quantifies how reaction and transport mechanisms are affected under ventilation flow conditions. Thin diffusive boundary layers near the walls confine reactions to this region, limiting catalyst utilisation and resulting in removal efficiencies <0.1%< 0.1\% for all pollutants, even under high irradiance (Figure 5). For CH4\mathrm{CH}_4, our analysis predicts that duct-scale operation can achieve a net climate benefit (net-negative CO2e\mathrm{CO}_2\mathrm{e} emissions) when UV energy is already available (e.g., in pre-existing disinfection systems), even after accounting for the embodied carbon of the catalyst. This benefit is primarily enabled by the use of metal-free TiO2\mathrm{TiO}_2 coatings, which minimise material-related emissions compared to more complex catalyst formulations [24].

Several limitations require further investigation. The reported metrics isolate the catalytic contribution and do not include the bulk oxidation of CH4\mathrm{CH}_4 by reactive oxygen species and OH⋅\mathrm{OH}\cdot generated by the UV-C lamp [21, 25, 26]; total conversion efficiencies and the bulk reaction mechanism will be quantified in future work. The analysis assumes uniform irradiance, neglecting photon scattering and catalyst shadowing, which can create spatial variations in surface reactivity [6]. Catalyst ageing, deactivation and fouling are not included in the model and may reduce long-term performance [45]. Thus, the reported metrics reflect intrinsic catalytic behaviour under idealised conditions rather than long-term field performance. Avenues for future work include catalyst durability under humid and contaminant-containing feeds that are more representative of environmental methane sources. The potential formation of secondary species and partially oxidised by-products [46], has not been quantified and requires targeted experimental investigation. Addressing these factors is essential for assessing real-world PCO performance. Despite these limitations, the framework provides a foundation for the optimisation of PCO ventilation technologies. Integrating experimentally validated kinetics with detailed transport modelling allows quantitative evaluation of design modifications, including increased catalyst area, enhanced UV irradiance, or integration with complementary air-cleaning methods. Alternative ventilation system designs could also be explored [47]. For example, coating ventilation filters may enhance mass transfer and pollutant removal efficiency, as pollutants would be transported through the catalytic medium rather than merely over a coated surface. Future work could integrate sensor-driven control strategies to adjust UV irradiation or airflow dynamically based on real-time pollutant concentrations. A comprehensive life-cycle assessment will also be necessary to quantify the long-term environmental and operational sustainability of PCO systems.

In summary, our experimental and modelling results investigate TiO2\mathrm{TiO}_2-based PCO as a potential strategy for improving indoor air quality and, in the case of CH4\mathrm{CH}_4, predict that it could potentially achieve a net climate benefit if integrated into existing UV-illuminated infrastructure. The model provides a link between laboratory-scale experiments and duct-scale applications, offering a potential tool to guide the design of future low-carbon ventilation systems for mitigating indoor pollutants.

Acknowledgments: We acknowledge Grantham Foundation for supporting this research. SDT acknowledges funding from Research England’s E3 fund via the M³4Impact program.

Asymptotic analysis

In Section 4, experimental results are compared with numerical and asymptotic solutions to assess model performance. Asymptotic solutions provide physical insight into pollutant removal and enable simple predictions in parameter regimes where thin boundary layers make full numerical solutions computationally expensive. In this appendix, we derive asymptotic approximations for the pollutant concentration c^\hat{c} and conversion efficiency η\eta in three regimes. These regimes are defined by the relative strength of reaction (Da), diffusion (Pe) and adsorption (β\beta) compared to advection.

Region I and II: small Pe

We begin by integrating the advection–diffusion equation (10) across the channel and applying the wall flux conditions (12), which gives

32∫y^=01(1−(2y^−1)2)∂c^∂x^ dy^=∫y^=011Pe∂2c^∂y^2 dy^=−DaPec^(x^,0).(15)\frac{3}{2}\int_{\hat{y}=0}^{1}\left(1-(2\hat{y}-1)^2\right)\frac{\partial\hat{c}}{\partial\hat{x}}\,\mathrm{d}\hat{y}=\int_{\hat{y}=0}^{1}\frac{1}{\mathrm{Pe}}\frac{\partial^2\hat{c}}{\partial\hat{y}^2}\,\mathrm{d}\hat{y}=-\frac{\mathrm{Da}}{\mathrm{Pe}}\hat{c}(\hat{x},0). \tag*{(15)}

In the strong-diffusion limit, Pe≪1\mathrm{Pe}\ll1, cross-channel concentration gradients are expected to be small, so the leading-order concentration is nearly uniform in y^\hat{y} and depends only on x^\hat{x}, i.e., c^≈c^(x^)\hat{c}\approx\hat{c}(\hat{x}). Substituting this approximation into the cross-channel integrated equation (15) yields the leading-order ordinary differential equation (ODE)

∂c^∂x^=−DaPec^1+βc^,c^(0)=1.(16)\frac{\partial\hat{c}}{\partial\hat{x}}=-\frac{\mathrm{Da}}{\mathrm{Pe}}\frac{\hat{c}}{1+\beta\hat{c}},\qquad\hat{c}(0)=1. \tag*{(16)}

For β≪1\beta\ll1, (16) reduces to a linear ODE, whose solution is

c^≈exp⁡(−Dax^Pe).(17)\hat{c}\approx\exp\left(-\frac{\mathrm{Da}\hat{x}}{\mathrm{Pe}}\right). \tag*{(17)}

Substituting (17) into (13) gives the leading-order conversion efficiency

η≈1−exp⁡(−DaPe).(18)\eta\approx1-\exp\left(-\frac{\mathrm{Da}}{\mathrm{Pe}}\right). \tag*{(18)}

For β≫1\beta\gg1, integrating the ODE (16) with respect to x^\hat{x} gives the implicit relation

ln⁡(c^)+βc^=β−Dax^Pe.(19)\ln(\hat{c})+\beta\hat{c}=\beta-\frac{\mathrm{Da}\hat{x}}{\mathrm{Pe}}. \tag*{(19)}

Expanding c^=1+c^1/β+…\hat{c}=1+\hat{c}_1/\beta+\ldots in (19) and matching terms at O(1)O(1) yields the first-order correction

c^1=−Dax^Pe.(20)\hat{c}_1=-\frac{\mathrm{Da}\hat{x}}{\mathrm{Pe}}. \tag*{(20)}

Therefore, the concentration field can be approximated as

c^=1−Dax^βPe+….(21)\hat{c}=1-\frac{\mathrm{Da}\hat{x}}{\beta\mathrm{Pe}}+\ldots. \tag*{(21)}

Substituting the concentration field (21) into (13) yields the leading-order conversion efficiency

η=DaβPe+….(22)\eta=\frac{\mathrm{Da}}{\beta\mathrm{Pe}}+\ldots. \tag*{(22)}

Region III: small Da, large Pe

When Pe≫1\mathrm{Pe} \gg1, advection dominates cross-channel diffusion and a thin concentration boundary layer develops adjacent to the reactive wall at y^=0\hat{y} = 0. Retaining the leading-order terms in the advection–diffusion equation (10) in the near-wall region y^≪1\hat{y} \ll1 yields

6y^∂c^∂x^=1Pe∂2c^∂y^2.(23)6\hat{y}\frac{\partial\hat{c}}{\partial\hat{x}} = \frac{1}{\mathrm{Pe}}\frac{\partial^2 \hat{c}}{\partial\hat{y}^2}. \tag*{(23)}

with boundary conditions given by (12). For Da≪1\mathrm{Da} \ll1, the concentration field is expanded as

c^=1+Da c^1(x^,y^)+…,(24)\hat{c} = 1 + \mathrm{Da}\,\hat{c}_1(\hat{x},\hat{y}) + \ldots, \tag*{(24)}

where c^1\hat{c}_1 satisfies the linear boundary-layer equation (23). For β≪1\beta\ll1, the wall-flux condition reduces to c^1y^(x^,0)=1\hat{c}_{1\hat{y}}(\hat{x},0) = 1, and we seek a similarity solution of the form

c^1=x^1/3Pe1/3f(ξ),ξ=y^ Pe1/3x^1/3.(25)\hat{c}_1 = \frac{\hat{x}^{1/3}}{\mathrm{Pe}^{1/3}}f(\xi), \qquad\xi= \frac{\hat{y}\,\mathrm{Pe}^{1/3}}{\hat{x}^{1/3}}. \tag*{(25)}

Substituting the asymptotic expansion (24) and similarity form (25) into the advection–diffusion equation (23), together with the boundary conditions (10)–(12), yields the following boundary-value problem

f′′−2ξf+2ξ2f′=0,f′(0)=1,f(ξ→∞)→0.(26)f^{\prime\prime} - 2\xi f + 2\xi^2 f^\prime= 0, \qquad f^\prime(0) = 1, \qquad f(\xi\to\infty) \to0. \tag*{(26)}

The solution to the boundary-value problem (26) is

f=ξΓ(−1/3,2ξ3/3)Γ(−1/3).(27)f = \frac{\xi\Gamma(-1/3, 2\xi^3/3)}{\Gamma(-1/3)}. \tag*{(27)}

Substituting the solution (27) into the similarity solution (25) gives the first-order concentration field

c^1=x^1/3ξΓ(−1/3,2ξ3/3)Pe1/3Γ(−1/3).(28)\hat{c}_1 = \frac{\hat{x}^{1/3}\xi\Gamma(-1/3, 2\xi^3/3)}{\mathrm{Pe}^{1/3}\Gamma(-1/3)}. \tag*{(28)}

Using the definition of conversion efficiency (13), the leading-order contribution is

η=−Da∫01c^1(1,y^) dy^+….(29)\eta= -\mathrm{Da}\int_0^1 \hat{c}_1(1,\hat{y})\,\mathrm{d}\hat{y} + \ldots. \tag*{(29)}

Substituting the similarity solution (28) into (29) and changing variables to the similarity coordinate ξ=y^ Pe1/3\xi= \hat{y}\,\mathrm{Pe}^{1/3} (with x^=1\hat{x} = 1) gives

η=−Da∫01ξΓ(−1/3,2ξ3/3)Pe1/3Γ(−1/3) dy^+…=−DaPe1/3∫0∞ξΓ(−1/3,2ξ3/3)Pe1/3Γ(−1/3) dξ+….(30)\eta= -\mathrm{Da}\int_0^1 \frac{\xi\Gamma(-1/3, 2\xi^3/3)}{\mathrm{Pe}^{1/3}\Gamma(-1/3)}\,\mathrm{d}\hat{y} + \ldots= -\frac{\mathrm{Da}}{\mathrm{Pe}^{1/3}}\int_0^\infty\frac{\xi\Gamma(-1/3, 2\xi^3/3)}{\mathrm{Pe}^{1/3}\Gamma(-1/3)}\,\mathrm{d}\xi+ \ldots. \tag*{(30)}

Evaluating the integral in (30) gives the leading-order conversion efficiency

η=−Da(3/2)2/3Γ(1/3)2Γ(−1/3)Pe2/3+…≈0.43DaPe2/3.(31)\eta= -\frac{\mathrm{Da}(3/2)^{2/3}\Gamma(1/3)}{2\Gamma(-1/3)\mathrm{Pe}^{2/3}} + \ldots\approx\frac{0.43\mathrm{Da}}{\mathrm{Pe}^{2/3}}. \tag*{(31)}

Note that Γ(−1/3)<0\Gamma(-1/3) < 0, so the leading-order expression is positive, as required for a physical conversion efficiency. For β≫1\beta\gg1, the expansion (24) remains valid, but the wall-flux condition (12) reduces to

∂c^1∂y^∣y^=0=Daβ.(32)\left.\frac{\partial\hat{c}_1}{\partial\hat{y}}\right|_{\hat{y}=0} = \frac{\mathrm{Da}}{\beta}. \tag*{(32)}

The corresponding similarity solution, satisfying the wall-flux condition (32), is

c^1=Dax^1/3βPe1/3f(ξ),ξ=y^Pe1/3x^1/3.(33)\hat{c}_1 = \frac{\mathrm{Da}\hat{x}^{1/3}}{\beta\mathrm{Pe}^{1/3}} f(\xi), \qquad\xi= \frac{\hat{y}\mathrm{Pe}^{1/3}}{\hat{x}^{1/3}}. \tag*{(33)}

Substituting the asymptotic expansion (24) and similarity solution (33) into the advection–diffusion equation (23), along with the boundary conditions (12), yields the same ODE and boundary conditions as in (26). The solution of the boundary-value problem is therefore identical to (27), yielding the first-order concentration field

c^1=Dax^1/3ξΓ(−1/3,2ξ3/3)βPe1/3Γ(−1/3).(34)\hat{c}_1 = \frac{\mathrm{Da}\hat{x}^{1/3}\xi\Gamma\left(-1/3,2\xi^3/3\right)}{\beta\mathrm{Pe}^{1/3}\Gamma(-1/3)}. \tag*{(34)}

and the leading-order conversion efficiency

η=−Da2(3/2)2/3Γ(1/3)2βΓ(−1/3)Pe2/3+⋯≈0.43DaβPe2/3.(35)\eta= -\frac{\mathrm{Da}^2(3/2)^{2/3}\Gamma(1/3)}{2\beta\Gamma(-1/3)\mathrm{Pe}^{2/3}}+\cdots\approx\frac{0.43\mathrm{Da}}{\beta\mathrm{Pe}^{2/3}}. \tag*{(35)}

Region IV: large Da, large Pe

When Da≫1\mathrm{Da} \gg1, the concentration at the reactive surface y^=0\hat{y}=0 is nearly zero, consistent with the wall-flux condition (12). We therefore consider the boundary layer near y^=0\hat{y}=0 once more. The concentration field is expanded in inverse powers of Da\mathrm{Da} as

c^=c^0(x^,y^)+1Dac^1(x^,y^)+⋯ ,(36)\hat{c} = \hat{c}_0(\hat{x},\hat{y}) + \frac{1}{\mathrm{Da}}\hat{c}_1(\hat{x},\hat{y})+\cdots, \tag*{(36)}

where the leading-order concentration field satisfies the boundary-layer equation (23) with boundary conditions

c^0(0,y^)=1,c^0(x^,0)=0,∂c^0∂y^∣y^=1=0.(37)\hat{c}_0(0,\hat{y}) = 1,\qquad\hat{c}_0(\hat{x},0) = 0,\qquad\left.\frac{\partial\hat{c}_0}{\partial\hat{y}}\right|_{\hat{y}=1}=0. \tag*{(37)}

To reduce the boundary-layer problem to an ODE, we introduce the similarity variable

c^0=f(ξ),ξ=y^Pe1/3x^1/3.(38)\hat{c}_0 = f(\xi),\qquad\xi= \frac{\hat{y}\mathrm{Pe}^{1/3}}{\hat{x}^{1/3}}. \tag*{(38)}

Substituting the similarity solution (38) into the boundary-layer equation and the boundary conditions (23)–(37) reduces the problem to the ODE

f′′+2ξ2f′=0,f(0)=0,f(ξ→∞)→1.(39)f'' + 2\xi^2 f' = 0,\qquad f(0) = 0,\qquad f(\xi\to\infty) \to1. \tag*{(39)}

The solution to the boundary value problem (39) is

f=1−Γ(1/3,2ξ3/3)Γ(1/3).(40)f = 1 - \frac{\Gamma\left(1/3,2\xi^3/3\right)}{\Gamma(1/3)}. \tag*{(40)}

Using the asymptotic expansion (36) and the leading-order similarity solution (38), the conversion efficiency (8) at leading order is

η=1−∫01c^0(x^=1,y^) dy^+⋯=∫0∞Γ(1/3,2ξ3/3)Pe1/3Γ(1/3) dξ+⋯(41)\eta= 1 - \int_{0}^{1} \hat{c}_0(\hat{x}=1,\hat{y})\,\mathrm{d}\hat{y}+\cdots= \int_{0}^{\infty}\frac{\Gamma(1/3,2\xi^3/3)}{\mathrm{Pe}^{1/3}\Gamma(1/3)}\,\mathrm{d}\xi+\cdots \tag*{(41)}

Evaluating the integral

∫0∞Γ(1/3,2ξ3/3)Pe1/3Γ(1/3) dξ=(3/2)1/3Γ(2/3)Pe1/3Γ(1/3),(42)\int_{0}^{\infty}\frac{\Gamma(1/3,2\xi^3/3)}{\mathrm{Pe}^{1/3}\Gamma(1/3)}\,\mathrm{d}\xi= \frac{(3/2)^{1/3}\Gamma(2/3)}{\mathrm{Pe}^{1/3}\Gamma(1/3)}, \tag*{(42)}

where the change of variables ξ=y^Pe1/3\xi=\hat{y}\mathrm{Pe}^{1/3} has been used to transform the integral to the similarity variable. Substituting the integral result (42) into the conversion efficiency expression (41) yields the leading-order conversion efficiency

η=(3/2)1/3Γ(2/3)Pe1/3Γ(1/3)+⋯≈0.58Pe1/3.(43)\eta= \frac{(3/2)^{1/3}\Gamma(2/3)}{\mathrm{Pe}^{1/3}\Gamma(1/3)}+\cdots\approx\frac{0.58}{\mathrm{Pe}^{1/3}}. \tag*{(43)}

Methodology for calculating net carbon dioxide equivalent emissions rates from photocatalytic oxidation

This appendix describes the methodology used to quantify the net climate impact of CH4_4 PCO on UV-illuminated TiO2_2. The net CO2_2e emission rate (g/s) associated with PCO is defined as the sum of four terms: (i) direct CO2_2 produced by the stoichiometric conversion of CH4_4, (ii) the avoided climate forcing associated with CH4_4 removal, (iii) indirect CO2_2 emissions from UV energy use, and (iv) the embodied carbon of the photocatalyst material. The parameter values used in these calculations are listed in Table 3. The total net CO2_2e balance is given by:

net CO2e emission rate=CO2 production rate−CO2e removal rate+CO2 UV emission rate+CO2e material emission rate,(44)\text{net CO}_2\text{e emission rate} = \text{CO}_2\text{ production rate} - \text{CO}_2\text{e removal rate} + \text{CO}_2\text{ UV emission rate} + \text{CO}_2\text{e material emission rate}, \tag*{(44)}

with each term defined in Sections B.1–B.4.

Carbon dioxide production rate

The PCO of CH4\mathrm{CH_4} follows the reaction CH4+2O2→CO2+2H2O\mathrm{CH_4 + 2O_2 \to CO_2 + 2H_2O}, which produces one mole of CO2\mathrm{CO_2} per mole of CH4\mathrm{CH_4} converted. The experimentally measured CH4\mathrm{CH_4} conversion rate (Section 2), reported in molecules per second, is converted to moles per second using Avogadro’s number and multiplied by the molar mass of CO2\mathrm{CO_2} (44 g/mol) to obtain the CO2\mathrm{CO_2} production rate in g/s.

Carbon dioxide equivalent removal rate

Because CH4\mathrm{CH_4} has a high GWP, its conversion results in a net reduction in CO2e\mathrm{CO_2e}. Using the 20-year GWP value (GWP = 84 [4]), the avoided emissions per mole of CH4\mathrm{CH_4} converted are (GWP−1)×MCO2(\mathrm{GWP} - 1) \times M_{\mathrm{CO_2}}, where the subtraction of 1 accounts for the single mole of CO2\mathrm{CO_2} produced during oxidation. Multiplying this factor by the CH4\mathrm{CH_4} conversion rate yields the CO2e\mathrm{CO_2e} removal rate in g/s.

Carbon dioxide UV emission rate

Continuous UV illumination of the photocatalyst requires electrical power. The electrical energy consumption is calculated as E=PUV×topE = P_{\mathrm{UV}} \times t_{\mathrm{op}}, where PUV=25P_{\mathrm{UV}} = 25 W represents the typical power of UV lamps used in ventilation-integrated PCO systems [48], excluding high-power lamps (≥500\ge500 W) not applicable in this context, and top=24×3600=86400t_{\mathrm{op}} = 24 \times3600 = 86400 s/day. The annual electrical demand is converted to CO2\mathrm{CO_2} emissions using an electricity emissions factor of 200 gCO2\mathrm{gCO_2}/kWh [49]. Dividing the annual CO2\mathrm{CO_2} emissions by the total number of seconds in a year yields the CO2\mathrm{CO_2} emission rate from UV operation in g/s.

Embodied carbon in photocatalyst materials

The embodied CO2e\mathrm{CO_2e} associated with TiO2\mathrm{TiO_2} production is accounted for using a material emissions factor of 4 gCO2e/gTiO2\mathrm{gCO_2e/gTiO_2} [44]. The total TiO2\mathrm{TiO_2} mass is w=3.2w = 3.2 g, corresponding to a coating density of 80 g/m2\mathrm{g/m^2} [50] applied over a 0.04 m20.04\ \mathrm{m^2} ventilation panel. The total embodied emissions, wew_e, are considered as an annual material burden for the system, yielding a CO2e\mathrm{CO_2e} material emission rate in g/s.

Calculation of total net carbon dioxide equivalent emissions

The net climate impact of the photocatalytic system is calculated by summing all contributions in (44). This expression accounts for the climate benefit of CH4\mathrm{CH_4} removal as well as the CO2e\mathrm{CO_2e} contributions from UV operation and catalyst material production. Results for the UV intensities, inlet CH4\mathrm{CH_4} concentrations, and flow rates investigated experimentally (Section 2) are presented in Table 2. A negative net CO2e\mathrm{CO_2e} emission rate indicates that the photocatalytic system provides a net climate benefit.

References

  1. [1]I. Manisalidis et al. “Environmental and health impacts of air pollution: A review”. In: Front. Public Health 8 (2020), p. 14.
  2. [2]World Health Organization et al. WHO global air quality guidelines: particulate matter (PM2.5 and PM10), ozone, nitrogen dioxide, sulfur dioxide and carbon monoxide. World Health Organization, 2021.
  3. [3]B. S. Sosa et al. “Human health risk due to variations in PM10–PM2.5 and associated PAHs levels”. In: Atmos. Environ. 160 (2017), pp. 27–35.
  4. [4]P. Kumar. “Climate change and cities: Challenges ahead”. In: Front. Sustain. Cities 3 (2021), p. 645613.
  5. [5]M. W. Jones et al. “National contributions to climate change due to historical emissions of carbon dioxide, methane, and nitrous oxide since 1850”. In: Sci. Data 10.1 (2023), p. 155.DOI
  6. [6]M. Malayeri, F. Haghighat, and C.-S. Lee. “Modeling of volatile organic compounds degradation by photocatalytic oxidation reactor in indoor air: A review”. In: Build. Environ. 154 (2019), pp. 309–323.DOI
  7. [7]I. C. Prentice et al. “The carbon cycle and atmospheric carbon dioxide”. In: Climate Change 2001: The Scientific Basis, Intergovernmental Panel on Climate Change (2001).
  8. [8]T. Boningari and P. G. Smirniotis. “Impact of nitrogen oxides on the environment and human health: Mn-based materials for the NOx abatement”. In: Curr. Opin. Chem. Eng. 13 (2016), pp. 133–141.
  9. [9]J. Zhang, Y. Wei, and Z. Fang. “Ozone pollution: A major health hazard worldwide”. In: Front. Immunol. 10 (2019), p. 2518.DOI
  10. [10]R. Randall, R. B. Jackson, and A. Majumdar. “Cost modeling of photocatalytic decomposition of atmospheric methane and nitrous oxide”. In: Environ. Res. Lett. 19.6 (2024), p. 064015.DOI
  11. [11]S. D. Tomlinson et al. “Harnessing natural and mechanical airflows for surface-based atmospheric pollutant removal”. In: arXiv (2025), arXiv:2503.11803.arxiv.org/abs/2503.11803
  12. [12]J. Ma et al. “Environmental catalytic city: New engine for air pollution control”. In: J. Environ. Sci. 156 (2025), pp. 576–583.
  13. [13]G. Zhang et al. “Multivariate modeling of intrinsic kinetics for gas-solid heterogeneous photocatalytic reaction: A general method for different pollutant-photocatalyst systems”. In: Chem. Eng. J. 479 (2024), p. 147651.DOI
  14. [14]N. A. B. Timmerhuis, J. A. Wood, and R. G. H. Lammertink. “Connecting experimental degradation kinetics to theoretical models for photocatalytic reactors: The influence of mass transport limitations”. In: Chem. Eng. Sci. 245 (2021), p. 116835.
  15. [15]B. Yu et al. “Experiments and kinetics of solar PCO for indoor air purification in PCO/TW system”. In: Build. Environ. 115 (2017), pp. 130–146.DOI
  16. [16]H. S. Russell et al. “A review of photocatalytic materials for urban NOx remediation”. In: Catalysts 11.6 (2021), p. 675.DOI
  17. [17]M. M. Ballari et al. “Modelling and experimental study of the NOx photocatalytic degradation employing concrete pavement with titanium dioxide”. In: Catal. Today 151.1–2 (2010), pp. 71–76.
  18. [18]L. Pennacchio et al. “Physical and practical constraints on atmospheric methane removal technologies”. In: Environmental Research Letters 19.10 (2024), p. 104058. DOI: 10.1088/1748–9326/ad7 C. Hickey and M. Allen. “Economics of Enhanced Methane Oxidation Relative to Carbon Dioxide Removal”. In: Environ. Res. Lett. 19.6 (2024), p. 064043.
  19. [20]S. Abernethy, M. I. Kessler, and R. B. Jackson. “Assessing the potential benefits of methane oxidation technologies using a concentration-based framework”. In: Environ. Res. Lett. 18.9 (2023), p. 094064.
  20. [21]M. Krogsbøll et al. “Efficient mitigation of dilute methane, ammonia, and odor in ventilation air from cow and pig barns and a biogas plant: photoreactor field demonstration”. In: ACS ES&T Air 2.8 (2025), pp. 1648–1655.
  21. [22]V. Rauchenwald et al. “New method of destroying waste anesthetic gases using gas-phase photochemistry”. In: Anesthesia & Analgesia 131.1 (2020), pp. 288–297.
  22. [23]A. M. Tsopelakou et al. “Exploring the bounds of methane catalysis in the context of atmospheric methane removal”. In: Environ. Res. Lett. 19.5 (2024), p. 054020.
  23. [24]A. M. Tsopelakou et al. “Evaluating the potential of thermal catalysis for environmental methane mitigation”. In: Sustain. Sci. Technol. 3.2 (2026), p. 024002.
  24. [25]L. Pennacchio et al. “Physical and practical constraints on atmospheric methane removal technologies”. In: Environ. Res. Lett. 19.10 (2024), p. 104058.
  25. [26]N. Iversen and P. Roslev. “Mitigation of atmospheric and elevated methane by photochemical oxidation at ambient conditions”. In: Sci. Total Environ. 976 (2025), p. 179338.
  26. [27]I. M. S. Anekwe and Y. M. Isa. “Unlocking catalytic longevity: a critical review of catalyst deactivation pathways and regeneration technologies”. In: Energy Adv. 4.9 (2025), pp. 1075–1113.
  27. [28]D. Dissanayake et al. “Partial oxidation of methane to carbon monoxide and hydrogen over a Ni/Al2O3 catalyst”. In: J. Catal. 132.1 (1991), pp. 117–127.
  28. [29]MATLAB. The MathWorks, Inc. Natick, Massachusetts, 2025.
  29. [30]M. I. Kessler et al. “A Humidity-Tolerant Photocatalyst for Methane Removal”. In: Environ. Sci. Technol. 60.7 (2026), pp. 5442–5452.
  30. [31]B. Han et al. “A thermo-photo hybrid process for steam reforming of methane: highly efficient visible light photocatalysis”. In: Chem. Commun. 55.54 (2019), pp. 7816–7819.
  31. [32]L. Luo et al. “Binary Au–Cu reaction sites decorated ZnO for selective methane oxidation to C1 oxygenates with nearly 100% selectivity at room temperature”. In: J. Am. Chem. Soc. 144.2 (2021), pp. 740–750.
  32. [33]Y. Fan et al. “Selective photocatalytic oxidation of methane by quantum-sized bismuth vanadate”. In: Nat. Sustain. 4.6 (2021), pp. 509–515.
  33. [34]H. Yoshida et al. “Hydrogen production from methane and water on platinum loaded titanium oxide photocatalysts”. In: J. Phys. Chem. C 112.14 (2008), pp. 5542–5551.
  34. [35]Y. Jiang et al. “Enabling specific photocatalytic methane oxidation by controlling free radical type”. In: J. Am. Chem. Soc. 145.4 (2023), pp. 2698–2707.
  35. [36]H. Song et al. “Selective photo-oxidation of methane to methanol with oxygen over dual-cocatalyst-modified titanium dioxide”. In: ACS Catal. 10.23 (2020), pp. 14318–14326.
  36. [37]D. Hu et al. “Thermocatalysis enables photocatalytic oxidation of methane to formic acid at room temperature beyond the selectivity limits”. In: Cell Rep. Phys. Sci. 4.2 (2023). H. Li et al. “Photocatalytic degradation of lignin on synthesized Ag–AgCl/ZnO nanorods under solar light and preliminary trials for methane fermentation”. In: Bioresour. Technol. 175 (2015), pp. 494–501.
  37. [39]H. Song et al. “Visible-light-mediated methane activation for steam methane reforming under mild conditions: a case study of Rh/TiO₂ catalysts”. In: ACS Catal. 8.8 (2018), pp. 7556–7565.
  38. [40]X. Chen et al. “Photocatalytic oxidation of methane over silver decorated zinc oxide nanocatalysts”. In: Nat. Commun. 7.1 (2016), p. 12273.
  39. [41]J. Wei and E. Iglesia. “Reaction pathways and site requirements for the activation and chemical conversion of methane on Ru-based catalysts”. In: J. Phys. Chem. B 108.22 (2004), pp. 7253–7262.
  40. [42]J. Wei and E. Iglesia. “Mechanism and site requirements for activation and chemical conversion of methane on supported Pt clusters and turnover rate comparisons among noble metals”. In: J. Phys. Chem. B 108.13 (2004), pp. 4094–4103.
  41. [43]L. Li et al. “Efficient Sunlight-Driven Dehydrogenative Coupling of Methane to Ethane over a Zn+-Modified Zeolite”. In: Angew. Chem. 123.36 (2011).
  42. [44]Rio Tinto. Our approach to climate change: 2020 Climate Change Report. Accessed: 2025-08-07. 2020. URL: https://www.riotinto.com/-/media/Content/Documents/Invest/Reports/Climate-
  43. [45]Z. Zhou et al. “Effect of sulfur poisoning during worldwide harmonized light vehicles test cycle on NOₓ reduction performance and active sites of selective catalytic reduction filter”. In: Catalysts 15.7 (2025), p. 682.
  44. [46]R. Pitchai and K. Klier. “Partial oxidation of methane”. In: Catal. Rev. Sci. Eng. 28.1 (1986), pp. 13–88.
  45. [47]S. D. Tomlinson et al. “Modelling laminar flow in V-shaped filters integrated with catalyst technologies for atmospheric pollutant removal”. In: Int. J. Heat Mass Transfer 257 (2026), p. 128206.
  46. [48]S. Escobedo and H. de Lasa. “Photocatalysis for air treatment processes: Current technologies and future applications for the removal of organic pollutants and viruses”. In: Catalysts 10.9 (2020), p. 966.
  47. [49]European Environment Agency. Greenhouse Gas Emission Intensity of Electricity Generation (g CO₂e/kWh). European Environment Agency, European Topic Centre on Climate Change Mitigation and Energy. Chart and country-level data, EU average emission intensity. June 2024. URL: https://www.eea.europa.eu/en/analysis/maps-and-charts/co2-emission-inter
  48. [50]Johnson Matthey Catalysts Ltd. SCR Catalyst. U.S. Patent Application No. US2020/0108376. 2020. URL: https://www.freepatentsonline.com/20200108376.pdf.
  49. [51]P. S. Hammershøi, A. D. Jensen, and T. V. W. Janssens. “Impact of SO₂-poisoning over the lifetime of a Cu-CHA catalyst for NH₃-SCR”. In: Appl. Catal. B 238 (2018), pp. 104–110.

Paper details

vlnc:W_5fbqk4bu
Published
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents