WorksPhysics and Astronomy
High mobility transport in isotopically-enriched C and C exfoliated graphene
Abstract
Graphene quantum dots are promising candidates for qubits due to weak spin-orbit and hyperfine interactions. The hyperfine interaction, controllable via isotopic purification, could be the key to further improving the coherence. Here, we use isotopically enriched graphite crystals of both C and C grown by high-pressure-high-temperature method to exfoliate graphene layers. We fabricated Hall bar devices and performed quantum transport measurements, revealing mobilities exceeding and a long mean free path of microns, which are as high as natural graphene. Shubnikov-de Haas oscillations, quantum Hall effect up to the filling factor of one, and Brown-Zak oscillations due to the alignment of hBN and graphene are observed thanks to the high mobility. These results constitute a material platform for physics and engineering of isotopically-enriched graphene qubits.
Introduction
Graphene quantum dots are among the most promising candidates as platforms for spin qubits[1, 2, 3] thanks to the weak spin-orbit coupling and hyperfine interactions. Understanding the hyperfine interaction is a strategy to improve the qubit coherence in several systems such as GaAs[4, 5, 6, 7] and Si-based systems [8, 9, 10]. The hyperfine interaction has also been investigated in -enriched carbon nanotube quantum dots [11] and it was theoretically proposed that graphene quantum dots could benefit from isotope purification.[1, 12, 13, 14], modulating the ratio of (nuclear spin 0) and (nuclear spin ) (see Appendix § 1.1.1). Comparing the results of and -enrichment would enable the direct investigation of the effect of hyperfine interaction. While isotopically-enriched graphene has been realized, they have been made by the chemical vapor deposition (CVD) method [15, 16], whose electronic quality is usually not as high as for exfoliated samples and thus challenging for qubit fabrication.
In this work, we investigate high-quality exfoliated graphene devices out of -enriched (99.7%) and -enriched (91.4%) graphites. We synthesize enriched graphite by the high-pressure-high-temperature method [17, 18]. We then establish a recipe to exfoliate the layered crystals to obtain monolayer and bilayer graphene. The isotope effect is characterized by mass spectroscopy and Raman spectroscopy, showing a clear difference between and graphene. After confirming the enrichment, we fabricate a Hall bar device from each kind of graphite and perform quantum transport measurements. For both graphene samples, high mobility () and long mean free path () are demonstrated. These values demonstrate that the electronic quality of graphene remains as high as natural graphene after isotopic enrichment. We also observe the Shubnikov-de Haas oscillations, quantum Hall effect, and Brown-Zak oscillations, which confirm the quality of the sample. This result forms the basis for building isotopically-enriched graphene qubits and investigating the role of hyperfine interactions.
Characterization Results
Enriched graphite and exfoliation
Figure 1(a) shows the optical picture of the crystal of -enriched and -enriched graphite. Hereafter, we call them graphite/graphene and graphite/graphene for convenience. Isotopically enriched graphite crystals are obtained using Co-Ti solvents by a temperature difference method under high pressure. This method modifies the high-pressure synthesis conditions of diamond single crystals in the graphite stability region of 3 GPa and 1600 °C for 20 hrs [19]. The carbon source material is dissolved in the molten solvent under high pressure and high temperature and precipitated as a graphite crystal. The source materials are -enriched diamond crystals prepared by CVD using -enriched methane gas (Tomei-diamond Co Ltd) and commercially available -enriched graphite. After high-pressure synthesis, the metallic solvents are removed with hot aqua regia, and the graphite crystals are purified with pure water.
Note that the crystal size ( mm) is relatively small compared to the natural graphite crystals, which can be up to of the order of cm. The relative isotope ratio found in the crystals is determined using inductively coupled plasma time-of-flight mass spectrometry (ICP-TOFMS). The ICP-TOFMS (icp-TOF2R, TOFWERK AG, Thun, Switzerland) is operated in low-mass mode and was coupled to an ArF excimer laser (193 nm, GeoLas C, Lambda Physik, Göttingen), equipped with a low dispersion ablation cell for minimally invasive sampling of the small crystals. The ratios of isotopes are determined for natural graphite, graphite, and graphite. The results of the natural graphite are used to calibrate the ratio for the other samples, assuming the natural abundance of . The result of the mass spectroscopy yields for the sample and for the sample, confirming the effect of enrichment. The relative concentrations of the isotopes determined by mass spectroscopy have a relatively large error because of the small amount of the sample available.
In spite of the relatively small size of the graphite crystals, exfoliation is possible for both and . We perform exfoliation by using the standard scotch tape method, where we deposit graphite onto the scotch tape and fold and peel apart the tape a certain number of times before the flakes are transferred onto a Si/SiO substrate. We compare exfoliation for folding and peeling apart the tape 4-6 times with 10-15 times. We analyze the chips under a microscope and record the size of the flakes. The statistics of the flake size (mono-, bi-, and trilayer graphene) is shown in Figure 1(b), together with an image of an example of a large bilayer flake. It turns out that after 4-6 times of exfoliation, it is possible to obtain 50 m scale graphene flakes of mono, bi, and tri layers. The same result is obtained for the graphene. These results demonstrate that the enriched and exfoliation is possible and that the flakes are available for fabricating devices.
Figure 1. (a) Optical picture of and graphite crystals. The minimum grid size in the background is 1 mm. (b) Histogram of graphene flake size. Inset shows a picture of the example bilayer flake. The scale bar is 50 m. (c) Raman spectrum of and graphene. Top: Monolayer graphene. Bottom: Bilayer graphene. (d) Top panel: Optical picture of the fabricated Hall bar. The scale bar is 10 m. Bottom panel: Schematic of the fabricated Hall bar. Source, drain, and voltage terminals are shown together with the geometric measurements.
Raman spectroscopy
The exfoliated graphene is further characterized by Raman spectroscopy (Horiba LabRAM HR Evolution UV-VIS-NIR). The laser energy and wavelength are 1 mW and 532 nm, respectively. We choose a flake larger than 10 m and perform a Raman spectrum measurement by changing the laser position. The data shown in Figure 1(c) is from the part of the graphene that is a few m inside from the edge of the flake. The measurements are done on mono and bilayer flakes. As shown in Figure 1(c), both and graphene show prominent G (1520-1580 cm), D+D″ (2360-2490 cm), 2D (2540-2710 cm), and 2D′ (3120-3250 cm) peaks. The numbers in the parentheses are typical ranges of the observed peak wavenumbers. We see a clear peak wavenumber shift between and . These differences are one of the most prominent signatures of the isotope effect because the nuclear mass difference results in a phonon frequency and Raman shift difference. We do not observe a shift between and natural graphene within the experimental resolution. After subtracting a linear background from the data, we fit all the peaks with Lorentzian functions. The fit parameters are in the table in Appendix B.
The obtained parameters are consistent with the ones reported in exfoliated natural graphene and isotopically enriched CVD graphene [20, 21, 22, 23, 24]. The measured wavenumber of the G peak, , for or natural graphene reported in Refs. [20, 21, 22, 23, 24] are between and of our measured values for graphene (for mono- and bilayer). The for graphene reported in [22, 24] is in the range of to of the values we measure for mono- or bilayer. Comparing the wavenumber of the 2D peak, , to literature values, it turns out that the values reported are generally slightly higher (up to ) than the values we measure. For the monolayer graphene , we find that our measurement aligns very well (within ) with the natural graphene measurement in [20]. However, the measurements in Refs. [22, 23, 24] find values - higher than what we measure for monolayer graphene as well as for monolayer graphene. Looking at the bilayer measurements for peaks [20], we find two peaks that are and apart. For [25] reports for graphene and for graphene. These values are consistent with what we measure.
We also estimate the isotopic concentration of graphene from the Raman shift using the relation [26]. Here, is the Raman shift of pure graphene, is atomic mass of , is the concentration of , and the atomic mass difference of and . For graphene, we obtain a enrichment using the 2D and 2D’ peaks and using the G peak. Since the G peak is sensitive to the distortion and carrier density [27], it can be affected by unintentional doping due to the charged impurity in the silicon substrate, making the peak shift. The estimation from 2D and 2D’ peaks is closer to the value obtained by the mass spectroscopy with a slight overestimation (). At around of , the deviation of Raman shifts by one modulates the concentration estimation by . Therefore, considering the resolution of the measurement, the estimation from the 2D and 2D’ peaks is consistent with the one from the mass spectroscopy.
Device fabrication
To characterize the transport quality of the isotopically enriched graphene, we fabricate Hall bars of and bilayer graphene as shown in Figure 1(d). A stack of hexagonal boron-nitride (top hBN)/bilayer graphene/hBN (bottom hBN)/graphite (back gate) is made by the poly-dimethylsiloxane/poly-carbonates dry transfer method. Electric contacts to the edge of the bilayer graphene are fabricated by etching the top hBN and depositing Cr/Au. After etching, a Hall bar is shaped by reactive ion etching ( and ). We measure the Hall bars in a dilution refrigerator with a base temperature of 55 mK. The bottom panel of Figure 1(d) shows the schematic of the device. The two contacts at each sample end are used as source and drain electrodes, where we inject current from the source to the grounded drain. The longitudinal and transverse voltages ( and ) are measured between the two contacts along and across the sides. The spacing between source and drain, and between the voltage contacts is 4 m and 1 m, respectively. We use a lock-in amplifier (Stanford Research Systems SR830) connected to the source in series with a 100 M resistance and apply an AC voltage of 1 V, generating an AC current of 10 nA. We synchronize the lock-in amplifier driving the current with the other two lock-in amplifiers. These lock-in amplifiers are then used to measure the resistances ( and at zero bias current). We apply a DC voltage (Yokogawa 7651 Programmable DC Source) to the back gate (not shown in the schematic).
Transport measurement
Figure 2(a) and (d) show the magnetic field and the carrier density dependence of the longitudinal resistance of and devices. The carrier density on the horizontal axis is estimated by measuring the classical Hall effect up to 100 mT and using the relation . We also obtain consistent values from a parallel plate capacitor model (, where is the capacitance between the graphene and the back gate and is the back gate voltage) and Shubnikov-de Haas measurements ().

Figure 2. Quantum transport measurement of (a,b,c) and (d,e,f) bilayer graphene. (a,d) as a function of magnetic field and carrier density . White dotted tilted lines fit the Shubnikov-de Haas oscillations with filling factors shown in the Figure. White dotted horizontal lines show the position at which the Brown-Zak oscillations appear. (b,e) Example traces of the quantum Hall effect at () and (). (c,f) Carrier density dependence of the mobility and the mean free path estimated from the low magnetic field data.
For both samples, clear fan-like structures departing from the charge neutrality point and expanding with magnetic field are seen, which is attributed to the Shubnikov-de Haas (SdH) oscillations. The oscillations appear already at around 1 T, testifying to our samples’ high mobility. White dotted tilted lines show the fitting to the filling factor of 1, 2, and 3 at around (for and ) and filling factor for 2, 6, and 10 at around (for only).
Additionally, in the sample, we see multiple Landau fans appearing at densities of around 4.09, 3.29, 2.30, 1.78, -2.06, and -2.31 . This is attributed to the additional Dirac points due to the unintended alignment between the graphene and one of the hBNs, forming a moiré superlattice [28]. This results in an energy spectrum for the charge carriers known as the Hofstadter butterfly and causes satellite Dirac peaks. Furthermore, at the intersections of the Landau fans, it predicts horizontal lines of peaks in called Brown-Zak oscillations [29, 30]. The horizontal lines in Figure 2(a) indicate the position of with an integer and the flux quanta. We discuss in Appendix C, the moiré unit cell size estimated from the Brown-Zak oscillations agrees with the one formed by graphene/hBN alignment. This observation is another piece of evidence for having a high-quality sample.
At a high magnetic field, we observe the quantum Hall effect, as shown in Figs. 2(b) and (e). For both samples, the integer quantum Hall effect is observed up to filling factor with quantized plateaus of and dips of . The significant drop of in beyond filling factor 1 ( T) is due to the Brown-Zak oscillations. We observe a similar drop whenever crosses the horizontal lines indicated in Figure 2(a).
We also estimate the mobility and mean free path by applying the classical Drude model to ( and are the width and the length of the sample) and at a low magnetic field ( mT). From the slope of the linear fit of up to 100 mT together with at 0 T, we determine and using the equations and . As seen in Figure 2(c) and (f), the mobility mostly ranges from to . The mobility becomes zero around charge neutrality and forms a peak with increasing . This behavior can be attributed to the difference in dominant scattering mechanisms (long-range Coulomb scattering at low density and short-range impurity scattering at high density) [31].
The mean free path reaches up to 1–5 m for both and . This value is comparable to the one reported in natural graphene. Note that the spacing between the contacts is of the same order of magnitude as the estimated mean free path, meaning that the transport in the sample is in the ballistic regime. In this regime, the Drude model has limited validity, and the mobility and mean free path are lower bound estimates.
We further perform a quantum Hall effect breakdown measurement, applying a DC current up to 10 A so that the quantum Hall effect (plateau in and zero in ) is no longer observed. In GaAs 2DEG systems, a large hysteresis in the current sweep direction before and after the breakdown is observed typically for odd filling factors due to dynamic nuclear polarization (spin transfer from electrons to nuclei) [32, 33]. We do not observe any clear hysteresis within our measurement precision (data is not shown here). To observe the effect of hyperfine interaction, more sophisticated measurements such as resistivity-detected NMR [34, 35, 36] or actually building a quantum dot and performing a and coherence time measurement would be useful.
Conclusion
In conclusion, we have presented high-mobility transport of exfoliated and graphene synthesized by the high-pressure-high-temperature technique. We identified distinct differences between and graphene by the mass and Raman spectroscopy. We also fabricated Hall bar devices and performed quantum transport measurements, revealing high mobility and a long mean free path. Shubnikov-de Haas, quantum Hall, and Brown-Zak effects up to the filling factor of one were observed thanks to the high mobility. These results pave the way for developing isotopically-enriched graphene qubits and investigating the role of hyperfine interactions in graphene quantum dots.
Acknowledgments
We are grateful for fruitful discussions and technical support from Lev Ginzburg, Chuyao Tong, Markus Niese, Peter Maerki, Thomas Baehler, and the ETH FIRST cleanroom facility staff. We acknowledge financial support by the European Graphene Flagship Core3 Project, H2020 European Research Council (ERC) Synergy Grant under Grant Agreement 951541, the European Union’s Horizon 2020 research and innovation programme under grant agreement number 862660/QUANTUM E LEAPS, the European Innovation Council under grant agreement number 101046231/FantastiCOF, NCCR QSIT (Swiss National Science Foundation, grant number 51NF40-185902). K.W. and T.T. acknowledge support from the JSPS KAKENHI (Grant Numbers 21H05233 and 23H02052) and World Premier International Research Center Initiative (WPI), MEXT, Japan.
Coherence time estimation
Following the steps of [1], we studied the effect of isotopic composition on the lifetime of coherent spin states () in graphene quantum dot qubits. While the different atomic masses of and may affect the spin-orbit coupling, it is believed that the hyperfine interaction limits the coherence time in graphene [1]. The limit on the coherence time set by the hyperfine interaction (hyperfine coherence time) depends on the composition of the spinless and the spin-1/2 . It can be estimated from the hyperfine coupling strength , the concentration and the number of atom in a dot using .
Compared to natural graphene (; : ) the purification level of our sample () would already increase the hyperfine coherence time by a factor of two. Further decreasing the concentration (99.99% purified ), would increase the coherence time by another factor of five, to around . This shows the strong sensitivity of the hyperfine coherence time on isotopic composition at low concentrations. For a dot size of atoms, this purification level of 99.99% would already mean that on average just one atom would be present per dot. By selecting the dots without any and thus no nuclear spins, one can completely lift the limitation of the coherence time by the hyperfine interaction.
Raman peaks fitting parameters
We fitted the Raman spectrum with Lorentzian function where is the peak amplitude, is the wavenumber, is the peak wavenumber, and is the linewidth (half-width-at-half-maximum). The results are shown below. We used a single Lorentzian function for and peaks, sum of two Lorentzian functions for peak, and sum of three Lorentzian functions for peak.
| Layers | 1 | 1 | 2 | 2 |
| Material | ||||
| 1584 | 1530 | 1581 | 1522 | |
| 8.143 | 5.316 | 11.14 | 9.983 | |
| 2678 | 2580 | 2646, 2681, 2704 | 2546, 2580, 2602 | |
| 21.431 | 22.296 | 14.98, 21.76, 31.32 | 13.49, 21.47, 29.96 | |
| 3247 | 3128 | 3248 | 3125 | |
| 8.455 | 11.274 | 8.709 | 10.61 | |
| 2479, 2457 | 2366, 2388 | 2458, 2489 | 2365, 2394 | |
| 41.27, 15.29 | 14.41, 36.46 | 26.04, 48.69 | 21.82, 41.55 |
Table I. Table of fit parameters for the Raman peaks. We fit the data with the sum of one to three Lorentzian functions (in the case we use multiple Lorentzian to fit, all fit parameters are shown in order and separated by comma).
Estimation of moire unit cell size from the Brown-Zak oscillation
We have estimated the moire cell size with two approaches. First, since the satellite Dirac peaks appear once all the available states in the moiré cell are filled, we can determine the area of the moiré cell from the average of the excess carrier density of the electron- and hole-side peaks and . Considering the 4-fold degeneracy in graphene, this condition corresponds to . The second approach uses the periodicity of the Brown-Zak oscillations, which appear if a rational number of flux quanta ( is an integer) passes through one moiré cell. The moiré cell area can then be determined from the positions of two adjacent Brown-Zak peaks in magnetic field ( and ) using . The lattice constant can be obtained from the area by simple geometric considerations as . Both methods give a consistent estimate of the moire unit cell size of 10 nm, which is reasonable for the graphene/hBN-aligned system.
References
References
- [1]B. Trauzettel, D. V. Bulaev, D. Loss, and G. Burkard, Nature Phys 3, 192 (2007).
- [2]M. Eich, R. Pisoni, A. Pally, H. Overweg, A. Kurzmann, Y. Lee, P. Rickhaus, K. Watanabe, T. Taniguchi, K. Ensslin, and T. Ihn, Nano Letters 18, 5042 (2018).
- [3]L. Banserus, K. Hecker, S. Möller, E. Icking, K. Watanabe, T. Taniguchi, C. Volk, and C. Stampfer, Nature Communications 13, 3637 (2022).
- [4]J. R. Petta, A. C. Johnson, J. M. Taylor, E. A. Laird, A. Yacoby, M. D. Lukin, C. M. Marcus, M. P. Hanson, and A. C. Gossard, Science 309, 2180 (2005).
- [5]L. C. Camenzind, L. Yu, P. Stano, J. D. Zimmerman, A. C. Gossard, D. Loss, and D. M. Zumbühl, Nat Commun 9, 3454 (2018).
- [6]T. Fujita, P. Stano, G. Allison, K. Morimoto, Y. Sato, M. Larsson, J.-H. Park, A. Ludwig, A. Wieck, A. Oiwa, and S. Tarucha, Phys. Rev. Lett. 117, 206802 (2016).
- [7]S. I. Erling(s)son and Y. V. Nazarov, Phys. Rev. B 66, 155327 (2002).
- [8]K. Eng, T. D. Ladd, A. Smith, M. G. Borselli, A. A. Kiselev, B. H. Fong, K. S. Holabird, T. M. Hazard, B. Huang, P. W. Deelman, I. Milosavljevic, A. E. Schmitz, R. S. Ross, M. F. Gyure, and A. T. Hunter, Science Advances 1, e1500214 (2015).
- [9]A. M. Tyryshkin, S. Tojo, J. J. L. Morton, H. Riemann, N. V. Abrosimov, P. Becker, H.-J. Pohl, T. Schenkel, M. L. W. Thewalt, K. M. Itoh, and S. A. Lyon, Nature Mater 11, 143 (2012).
- [10]K. M. Itoh and H. Watanabe, MRS Communications 4, 143 (2014).
- [11]H. O. H. Churchill, A. J. Bestwick, J. W. Harlow, F. Kuemmeth, D. Marcos, C. H. Stertka, S. K. Watson, and C. M. Marcus, Nature Phys 5, 321 (2009).
- [12]J. Fischer, B. Trauzettel, and D. Loss, Phys. Rev. B 80, 155401 (2009).
- [13]S. Sengupta, T. Frederiksen, and G. Giedke, Phys. Rev. B 107, 224433 (2023).
- [14]O. V. Yazyev, Nano Lett. 8, 1011 (2008).
- [15]V. Strenzke, J. M. Meyer, I. Grandt-Lonita, M. Prada, H.-S. Kim, M. Heilmann, J. M. J. Lopes, L. Tiemann, and R. H. Blick, Phys. Rev. B 105, 144303 (2022).
- [16]M. Wojtaszek, I. J. Vera-Marun, E. Whiteway, M. Hike, and B. J. van Wees, Phys. Rev. B 89, 035417 (2014).
- [17]T. Taniguchi and S. Yamaoka, Journal of Crystal Growth 222, 549 (2001).
- [18]T. Taniguchi and K. Watanabe, Journal of Crystal Growth 303, 525 (2007).
- [19]M. Miyakawa, C. Shinei, and T. Taniguchi, Jpn. J. Appl. Phys. 61, 045507 (2022).
- [20]D. Graf, F. Molitor, K. Ensslin, C. Stampfer, A. Jungen, C. Hierold, and L. Wirtz, Nano Letters 7, 238 (2007).
- [21]C. Neumann, S. Reichardt, P. Venezuela, M. Drögeler, L. Banszerus, M. Schmitz, K. Watanabe, T. Taniguchi, F. Mauri, B. Beschoten, S. V. Rotkin, and C. Stampfer, Nature Communications 6, 8429 (2015).
- [22]J. Ek-Weis, S. Costa, O. Frank, and M. Kalbac, The Journal of Physical Chemistry Letters 5, 549 (2014).
- [23]J. Sonntag, K. Watanabe, T. Taniguchi, B. Beschoten, and C. Stampfer, Phys. Rev. B 107, 074520 (2023).
- [24]E. del Corro, M. Kalbac, C. Fantini, O. Frank, and M. A. Pimenta, Phys. Rev. B 88, 155436 (2013).
- [25]S. D. Costa, J. E. Weis, O. Frank, M. Fridrichová, and M. Kalbac, 2D Materials 3, 025022 (2016).
- [26]B. R. Carvalho, Y. Hao, A. Righi, J. F. Rodríguez-Nieva, L. Colombo, R. S. Ruoff, M. A. Pimenta, and C. Fantini, Phys. Rev. B 92, 125406 (2015).
- [27]A. Das, S. Pisana, B. Chakraborty, S. Piscanec, S. K. Saha, U. V. Waghmare, K. S. Novoselov, H. R. Krishnamurthy, A. K. Geim, A. C. Ferrari, and A. K. Sood, Nat. Nanotechnol. 3, 210 (2008).
- [28]M. Yankowitz, J. Xue, D. Cormode, J. D. Sanchez-Yamagishi, K. Watanabe, T. Taniguchi, P. Jarillo-Herrero, P. Jacquod, and B. J. LeRoy, Nature Physics 8, 382 (2012).
- [29]B. Hunt, J. D. Sanchez-Yamagishi, A. F. Young, M. Yankowitz, B. J. LeRoy, K. Watanabe, T. Taniguchi, P. Moon, M. Koshino, P. Jarillo-Herrero, and R. C. Ashoori, Science 340, 1427 (2013).
- [30]R. Huber, M.-N. Steffen, M. Drienskiy, A. Sandner, K. Watanabe, T. Taniguchi, D. Pfannkuche, D. Weiss, and J. Eroms, Nature Communications 13, 2856 (2022).
- [31]J. H. Gosling, O. Makarovsky, F. Wang, N. D. Cottam, M. T. Greenaway, A. Patanè, R. D. Wildman, C. J. Tuck, L. Turanska, and T. M. Fromhold, Communications Physics 4 (2021).
- [32]A. M. Song and P. Omlling, Phys. Rev. Lett. 84, 3145 (2000).
- [33]M. Kawamura, H. Takahashi, K. Sugihara, S. Masubuchi, K. Hamaya, and T. Machida, Appl. Phys. Lett. 90, 022102 (2007).
- [34]G. Yusa, K. Muraki, K. Takashina, K. Hashimoto, and Y. Hirayama, Nature 434, 1001 (2005).
- [35]O. Stern, N. Freytag, A. Fay, W. Dietsche, J. H. Smet, K. von Klitzing, D. Schuh, and W. Wegscheider, Phys. Rev. B 70, 075318 (2004).
- [36]W. Desrat, D. K. Maude, M. Potemski, J. C. Portal, Z. R. Wasilewski, and G. Hill, Phys. Rev. Lett. 88, 256807 (2002).