WorksPhysics and Astronomy
Thermal-energy relaxation in chiral quantum Hall edge mode
Abstract
We study the nonequilibrium state generated by a real Ohmic contact (ROC) in the charge-fractionalization regime. We then investigate its thermal-energy relaxation along a quantum Hall edge mediated by a fictitious Ohmic contact (FOC) with large capacitance and perfect coupling to the edge. For cold Ohmic contacts, the electron distribution function and current noise are fully described by their equilibrium forms and the corresponding Fermi-Dirac distribution. In contrast, in the case of hot Ohmic contacts, strong thermalization effects do not drive the outgoing state into complete equilibrium. Both the distribution function and the noise retain signatures of the initial nonequilibrium state and therefore cannot be characterized solely by the effective contact temperature, contrary to common assumptions.
Relaxation.pdf
The experimental progress in hybrid mesoscale systems based on chiral QH edge states has triggered more accurate theoretical studies of phase coherence [1, 2, 3, 4, 5], charge and heat quantization [6, 7, 8, 9, 10, 11], relaxation and equilibration [12, 13, 14, 15, 16, 17, 18], and entanglement [19, 20, 21, 22], which are fundamental questions of mesoscopic physics. Among them, the investigation of the electron distribution function and equilibration along the QH edge states, for example, the unresolved issue of heat leakage [23, 24], remains an open question. In these experiments a quantum point contact (QPC) serves as an essential element. Namely, one prepares a non-equilibrium double-step distribution function with the help of biased partition QPC. Later, the evolution of distribution function along edge states is studied by measuring the conductance of tunneling current between two edges using the quantum dot or the second QPC as a detector [25].
Further progress in experimental techniques allowed experimentalists to realize systems, where the QH edge states are perfectly coupled to Ohmic contact, a mesoscale piece of metal with zero level spacing and finite charging energy, , where is the capacitance [26]. It is worth mentioning that the Ohmic contact has become a key element of new experimental and theoretical research [27]. The remarkable examples are the suppression of charge quantization caused by quantum fluctuations both in quantum and thermal regime [6, 7], heat Coulomb blockade effect [8, 9, 11], interaction induced recovery of the phase coherence [28, 29, 30], charge Kondo effect [31, 32], quantization of the anyonic heat flow [33], observation of the half-integer thermal Hall conductance [34, 35], the measurement of full counting statistics of electron currents with the help of quantum ammeter [36], and tunneling effects in multisite quantum Hall circuits [37, 38, 39]. Recently, an implementation of Ohmic contact with chiral edge channels allowed experimentalists to investigate relaxation and equilibration, measuring zero frequency noise for both integer and fractional filling factors [40]. This is the alternative method compared to conventional conductance measurements with respect to applied bias [25]. Subsequently, it has been used to
study quantized heat flow in the Hofstadter butterfly [41], the ballistic-to-diffusive transition in quantum Hall channels [42], dynamical Coulomb blockade under a temperature bias [43], and topological effects in thermal Hall conductance [44]. In addition to quantum Hall systems based on two-dimensional electron gas, this experimental technique has been used for other two-dimensional materials, including graphene, to investigate heat equilibration between integer and fractional quantum Hall edge modes [45] and heat transport in Moiré Chern bands of bilayer graphene [46, 47].
In this Letter, we study the energy relaxation by Ohmic contact strongly coupled to the QH edge state at filling factor (see Figure 1). The setup consists of a real Ohmic contact (ROC), which at zero capacitance () serves as an ideal electron fractionalizer. Two independently biased current sources, and with base temperature inject current return to the ROC. The sources biases, , are chosen such that the total accumulated charge in the ROC vanishes, namely , while the charge fluctuations remain nonzero, where is the quantum resistance. The equilibration in the ROC increases it’s temperature with non-zero dissipated power. Further, the measured distribution function and noise allow the study of the relaxation that occurs after the ROC. Relaxation is modeled by a fictitious Ohmic contact (FOC) with capacitance and negligible level spacing. The main interest is the study of relaxation modeled by the FOC with a large capacitance. Throughout the paper, we set .

Figure 1. Schematic of setup. It consists of the real Ohmic contact (left), a micrometer size piece of metal with negligible level spacing and capacitance . The real Ohmic contact is used to prepare the initial non-equilibrium distribution function with the help of two biased sources and . Relaxation of initially prepared state is modeled by a fictitious Ohmic contact with large capacitance , located after real Ohmic contact. The setup can be used to measure the distribution function, , and noise, , right before and after passing the region modeled by fictitious Ohmic contact.
Model and formulation of the problem. We use effective field theory [48] and the bosonization technique [49] to describe the QH edge states perfectly coupled to the Ohmic contact. According to effective theory, the collective fluctuations of the charge densities and currents in the QH edge channels are expressed in terms of the bosonic fields ,
where the index denotes the incoming and outgoing channels (see Figure 1). As stated in the bosonization technique, the electrons in these channels are represented by the vertex operators , so that the electron distribution function in the outgoing channel right after real or fictitious Ohmic contact reads
The prefactor in the expression for can be fixed in the end of the calculations by comparing with the equilibrium correlation function for free electrons. In particular, the equilibrium two-point correlation function of the incoming states results in a Fermi-Dirac distribution function . Apart from defining the electron distribution function, one can study the non-symmetrized noise of outgoing current after ROC and FOC,
where and the average is taken with respect to the incoming states. The symmetrized noise is defined as the sum of the positive and negative frequency components of the non-symmetrized noise, , which accounts for fluctuations associated with both emission and absorption processes and is an even function of frequency. At zero frequency, the non-symmetrized and symmetrized noises coincide. It is important to note that, in general, one cannot apply the relation
for zero frequency noise of current right after the ROC and FOC, since Wick’s theorem is invalid for the fermions outgoing from both Ohmic contacts. It will be shown later that this behavior is related to the nonequilibrium character of the outgoing state prepared by the ROC; due to the presence of electron-electron interactions between two incoming states and strong thermalization effects inside the ROC. In Eq. (4), is the quantum conductance, and is the temperature of the ROC and is the temperature of the FOC, which are obtained in Eqs. (8) and (9) below. These temperatures are different from due to thermalization effects.
Langevin equations and noise in the outgoing channel. We apply the Langevin equation method to evaluate the electron correlation function in Eq. (2). According to this method, the Ohmic contact serves as a reservoir of neutral excitations, which are accounted for by introducing Langevin currents into the equation of motion for the accumulated charge at the contact. The Langevin equations can be obtained rigorously using the bosonization technique for dynamics of bosonic fields [7, 8, 29, 36, 50, 51]. In the frequency domain, the outgoing currents immediately after the ROC are expressed in terms of the incoming currents and Langevin sources
where the subscript labels the channel and is the scattering coefficient. The superscript on the left hand side denotes that the outgoing state is non-equilibrium due to thermalization effects and charging energy. The first term in the denominator of the scattering coefficient, , counts the number of incoming and outgoing channels with respect to ROC. Similar equations can be written in the presence of additional FOC. The outgoing current after FOC has the form
where the scattering coefficients are given by and and is the capacitance of FOC. For the case of no FOC, , and one has . The two-point correlation functions of the incoming currents and Langevin sources according to the fluctuation-dissipation theorem are given by the equilibrium spectral function [52]
where and and . These correlation functions are used to determine the temperatures of the ROC and FOC, as well as to calculate the distribution function and noise.
Heating effects in Ohmic contacts. Before calculating the distribution function and noise, one needs to take into account the thermalization effects inside the Ohmic contacts, i.e., one needs to find the temperatures and in Eq. (7). To do this, we solve self-consistently the energy balance equations, i.e. conservation of incoming and outgoing heat currents, where the heat current is defined by Joule’s law, .
Further, using Joule’s law, we obtain the equation determining the ROC temperature,
where is a dimensionless function, and denotes the digamma function and is the gamma function. In the absence of FOC and in the small-capacitance regime, , the dimensionless function approaches . Therefore, the ROC temperature is given by [53]
This equation expresses the heating of the ROC as a result of thermalization. Incoming channels initially have the base temperature , while the symmetric voltage bias, , introduces an additional nonequilibrium energy proportional to . Furthermore, electron–electron interactions within the ROC redistribute this excess energy among the neutral modes , converting it into thermal energy and producing the temperature , which is indeed higher than the base temperature.
For the FOC, a similar analysis in the large-capacitance regime, , yields the following expression for the fictitious contact temperature [53]
Compared with the ROC, the FOC reaches a lower temperature because it receives only part of the excess energy generated by the two biased incoming channels; because it is coupled to one edge channel. The heating effects discussed here are used below for the calculation of the distribution function and noise. At the system is in equilibrium and at .
Noise in the outgoing channel. To find the outgoing noise after the FOC, we use Eq. (6) and arrive at the following equation
where is an equilibrium spectral function at temperature from Eq. (7). The non-equilibrium incoming noise, , in the case of fractionalizer (after ROC), when is given by [53]
Furthermore, at zero frequency and and we have ; thus, the outgoing noise is given by the incoming non-equilibrium noise [53], namely,
From the above equation, one can see that in the case of cold ROC, i.e. , the noise is given by the equilibrium result . However, in the hot ROC limit, , the result deviates from the equilibrium expectation at temperature . Instead, the zero-frequency outgoing noise is given by . Thus, Eq. (4) does not provide the correct result in this regime, since it assumes an equilibrium Fermi-Dirac distribution with temperature , yielding . It means that the relation for noise obtained using Wick’s theorem is not applicable, since the outgoing state is highly non-equilibrium and keeps the information about ROC, where the strong electron-electron interaction between two incoming states is present. However, in the limits followed by , one obtains . Nevertheless, the zero-frequency noise of the nonequilibrium ”in,1” outgoing ballistic channel downstream of the ROC remains described by Eq. (12).
Non-equilibrium distribution function. As a first step, we consider the prepared non-equilibrium state after the injection source, i.e. ROC. Our interest is the regime of small capacitance . In this case, the correlation function in Eq. (2) for the distribution function splits into two factors
where , with . The square roots in Eq. (13) arise from the fact that at , the ROC acts as the current fractionalizer and in Eq. (5). In case of cold ROC, , expanding the integrand with respect to in Eq. (2), the result for the distribution function to leading order is given by the equilibrium FD function at base temperature
The sub-leading contribution is equal to at . Qualitatively, the result of Eq. (14) is clear; the whole system is almost in equilibrium at and the result in leading order is given by the equilibrium distribution function of FD.
In case of hot ROC, , one gets the following results in low and high energy regimes [53]
where and at . From Eq. (15), one can see that the tail of the distribution function differs sufficiently from the equilibrium one at temperature , which has a pure exponential tail . Moreover, the sub-leading term in the low energy regime is different by factor compared to the equilibrium result . It is worth mentioning that in case of cold ROC the leading order contribution is given by the FD factor for both low- and high energy regimes. In contrast, the hot ROC’s case indicates the non-equilibrium nature of the prepared state more precisely in both low- and high energy regimes, since the temperature difference between incoming and outgoing states is huge, . Despite the conventional assumption that the ROC completely equilibrates the incoming states, our results, Eqs. (12) and (15), show that this picture is not accurate. These findings emphasize the limitations of assuming complete equilibration at the ROC.
In order to model the relaxation at the QH edge, we consider the case of one large FOC () and . In this case according to the scattering problem in Eq. (6), the correlation function in Eq. (2) is given by the product of the equilibrium two-point correlation function and the non-equilibrium part [53]
where is the equilibrium two-point correlation function at temperature as in Eq. (13) and the dimensionless function is responsible for non-equilibrium effects in exponent given by the integral over frequency [53]
and, to recall, is given in Eq. (10). In equilibrium and . Further, we substitute Eq. (16) in Eq. (2) and take into account that the main contribution to the integral comes from times , where one can replace the function in the integrand of in Eq. (17) by the delta function, . After some algebra, one arrives at the following result [53]
The pre-factor in the sub-leading term is given by zero frequency, i.e. . From the above equation, one can see that at the system is in equilibrium and the distribution function is given only by the leading order term, which indeed has the FD form at base temperature. Noise generated by QPC. The non-symmetrized zero-frequency noise can be calculated using the Landauer-Buttiker scattering approach locally at QPC [52]. The noise of the outgoing current in channel ”out, 1” after QPC is found to be given by the sum of two terms
The first term corresponds to the transmitted noise and has the form
where is the transparency of the QPC and . The first term is the contribution of incoming channel 3 and the second term is responsible for the noise coming after the ROC in the regime of charge fractionalizer (see Figure 1). One can see that in an almost equilibrium condition, , the transmitted noise is given by the equilibrium base temperature, . The second term in Eq. (19) describes the noise generated by QPC due to mixing of the incoming states from ROC and channel 3. It is given by the following time integral [53]
where the first factor is given in Eq. (13) in the fractionalizer regime and the second multiplier corresponds to free fermions at temperature originating from the channel in ”3”, thus .
For cold ROC, in the leading order of , one can replace the contact’s temperature with and obtain the cross-term [53]
The sub-leading correction to Eq. (22) is proportional to . In case of a hot ROC at , one can replace the finite-temperature correlation functions in the integrand of Eq. (21) with the zero temperature case and obtain the leading order behavior as follows [53]
The sub-leading correction to Eq. (23) is proportional to . In the case of FOC, the transmitted noise in Eq. (19) is given by Eq. (20). The noise generated by QPC has the following integral form [53]
where is given in Eq. (17). The effect of is perturbative and the main contribution to the integral, as in the case of the distribution function above, comes from times . First, we consider the case of cold Ohmic contacts, namely . In this case, one can replace all temperatures in leading order with and get [53]
In this case of hot Ohmic contacts one can replace the correlation function at temperature in the leading order with zero temperature case and get [53]
In summary, we have investigated thermal relaxation at a quantum Hall edge, modeled by the FOC with a large capacitance. The initial nonequilibrium state is generated by the ROC in the charge-fractionalization regime, providing an alternative mechanism to QPC partitioning. Both, electron distribution function and the electric current noise are calculated. For a cold ROC, when the system is close to equilibrium and thermalization effects are negligible, the electron distribution function and the noise at the quantum Hall edge are described by the corresponding equilibrium expressions determined by the FD distribution. However, when thermalization effects become significant, the outgoing state immediately downstream of the ROC cannot be described by an equilibrium FD distribution and by Johnson–Nyquist noise at the ROC temperature, despite the conventional assumption of complete equilibration by the ROC. Furthermore, we calculated the electron distribution function and the current noise generated by a QPC placed downstream of the ROC and FOC. We found that the subleading corrections to both the electron distribution function and the QPC-generated noise contain a universal prefactor determined by the difference between the nonequilibrium noise generated by the ROC and the noise of a free chiral channel.
The author thanks Patrick R. Behr for careful reading of the manuscript and fruitful discussions. The author acknowledges financial support from the United Arab Emirates University under the Startup Grant No. G00004974, UPAR Grant G00005479, and UAEU-AUA Grant G00005522.
AppendixRelaxation.pdf
HEAT CURRENT IN CHIRAL EDGE MODE
Using the definition of heat flux in the main text, and subtracting the contribution of the ground state, we get the following expression for the thermal current
This is the quantum heat flux and can be as well derived using FDT in equilibrium. If the channel is additionally biased, then according to Joules law, one needs to add the term proportional to square of electric current, namely . The Eq. (S-1) will be used below to calculate the thermalization effects in real and fictitious Ohmic contacts.
NON-EQUILIBRIUM FINITE FREQUENCY NOISE FOR REAL OHMIC CONTACT
We consider the real Ohmic contact (ROC) with capacitance as a source of heat current here. The solution to the outgoing current in channel ”1” in the frequency representation for the case of ROC is expressed in terms of the incoming currents and the Langevin sources
The first term of the scattering coefficient in the denominator counts the number of incoming and outgoing channels with respect to the ROC. Next, using Eq. (S-2), one can calculate the finite frequency noise of the outgoing current right after the ROC, namely and . After some algebra, the result is given by the following expression
where the ROC temperature, is unknown and can be calculated using self-consistent energy balance equations, i.e., the conservation of the incoming and outgoing heat currents. When real Ohmic contact functions as fractionalizer, the scattering coefficient is at . Then the finite frequency noise is equal to
Thus, two incoming equilibrium noises are split into two parts due to two outgoing chiral channels from ROC. This result is given in Eq. (11) of the main text. We are not interested in the noise after the fictitious Ohmic contact (FOC), but similarly one can show that after the FOC, i.e. , where and is an equilibrium spectral function at FOC’s temperature .
DETERMINATION OF TEMPERATURE OF REAL OHMIC CONTACT
To find the temperature , we solve the equations of the energy balance self-consistently, i.e., conservation of the incoming and outgoing heat currents, where the heat current is defined by Joule’s law,
where outgoing non-equilibrium current emitted from ROC. Using the above equation and the scattering matrix of currents for ROC, Eq. (S-2), we arrive at the following expression for determining contact’s temperature.
The first integrals on the left hand and right hand sides are given by Eq. (S-1). The second integral with capacitance can be rewritten using special functions as follows ()
where the dimensionless function equals the following expression
and is a digamma function, and is a gamma function. Further, choosing the symmetric bias and thus setting , we obtain the equation to determine the temperature of ROC
We are interested when ROC functions as a fractionalizer, i.e., . In this case at and we get the final result from Eq. (S-9), which is presented in Eq. (8) of the main text. At the system is in equilibrium and at .
Determination of temperature of fictitious Ohmic contact
In order to calculate the distribution function and noise further, one needs to take into account the thermalization effects inside the fictitious Ohmic contact (FOC). For the FOC it is given by conservation law, namely the incoming heat flux is equal to the outgoing heat flux. Using the definition of heat flux and the same steps as in the previous section, we arrive at the following equation
where are given by Eq. (S-3) for ROC. Next, we find the temperature in the case of small and large capacitance . To find it, we can use the above equation Eq. (S-10)
Using Eq. (S-1), the right hand side can be rewritten as follows
After introducing the dimensionless variable , the second term of the above equation takes the form
where is given in Eq. (S-8). Thus, we obtain the following equation to determine the temperature of FOC
For the case of ROC as a non-equilibrium source using in the fractionalizer regime, Eq. (S-4) we get the following expression for the left hand side of Eq. (S-11)
Therefore, the final equation for the determination of the temperature of FOC takes the following form
At large capacitance , one can use for , thus the temperature of the FOC is given by . At small capacitance , one can use for and the temperature of the FOC is given by . Our interest is the large capacitance case, which is discussed in the main text, Eq. (9).
CALCULATION OF INITIAL DISTRIBUTION FUNCTION FOR HOT ROC
According to Eqs. (2) and (9) of the main text, the initial non-equilibrium distribution function after ROC has the following form
where is given in Eq. (S-9). Calculations for the case of ”cold” ROC, , are straightforward, and since the system is almost in equilibrium, the main contribution is given by equilibrium FD distribution function (See Eq. (14) in the main text). In the regime of hot ROC, and low energies (for definiteness, positive values of are considered), we introduce the dimensionless variable , expand the oscillatory exponent and replace the correlation function with by the zero temperature case, namely
Next, keeping the leading order terms, we get the result for initial non-equilibrium distribution function at low energies
This result is given in Eq. (15) of the main text. Now, for the case of high energies, the oscillatory term is essential and cannot be expanded in Eq. (S-18). Therefore, in the leading order of the form of the integral is
To estimate this integral, we first shift the integration variable and get
In the above equation, the inner integration with respect to the variable is given by a gamma function and has the form
Using further at we arrive at the following result
where is the modified Bessel function of the second kind. Taking into account that for we arrive at Eq. (15) from the main text.
Calculation of distribution function after FOC
The distribution function after the FOC can be written as follows
where is an incoming non-equilibrium current after ROC and is equal to zero since the real Ohmic contact is not biased , and is a two-point free-fermion correlation function. The second factor is given by
One can see that and note that at , , and we recover the equilibrium Fermi-Dirac distribution. We are interested in large capacitance FOC at , thus the effect of is perturbative and expanding the exponent in Eq. (S-24) we have
The first term in Eq. (S-26) is given by the equilibrium FD distribution function at temperature
The second term is given by
At large capacitance , the main contribution to the integral comes from finite times and small frequencies , where the fraction can be replaced by the delta function . Therefore, we get
This result is given in Eq. (18) of the main text. The prefactor can be estimated using Eq. (S-3) for ROC. That is,
The above two results are presented in Eq. (18) of the main text.
QPC-generated noise right after the ROC
Using Landauer-Buttiker scattering approach, the non-symmetrized zero frequency noise (at zero frequency the non-symmetrized and symmetrized noises coincide) in the channel 1 right after the QPC is given by
In the above Eq. (S-31) the first and second terms are given by the FDT theorem; therefore,
The last term of Eq. (S-31) is given by the following time integral
Here, the second multiplier corresponds to free fermions at temperature originating from the channel ”in, 3”, thus . The first multiplier can be presented as follows
After some algebra, one can rewrite it as follows
Here, the first term is zero because the outgoing state of the ROC is not biased; therefore, we have
where is given in Eq. (S-4). We are interested in the limit of (fractionalizer); thus, using Eq. (S-4) one gets
After substitution into Eq. (S-33), we finally get the following integral
For cold ROC in the leading order of , one can replace the contact’s temperature with , and introducing the dimensionless variable we obtain the following.
The sub-leading correction is proportional to . In case of hot ROC at , one can replace the finite-temperature correlation functions in the integrand of Eq. (S-38) with zero temperature case and introducing the dimensionless variable we obtain the leading order behavior
The sub-leading correction is proportional to .
QPC-GENERATED NOISE RIGHT AFTER THE FOC
In case of FOC, the first two terms and are given by Eq. (S-32). The last term of noise has the following integral form
where is given in Eq. (S-25). At large frequencies of FOC the effect of is perturbative; therefore, the leading two terms are given by and
First, we consider the case of cold Ohmic contacts, namely . In this case, we can replace in the first term with and introducing the dimensionless variable of integration we obtain the following.
The sub-leading correction is proportional to . The second integral can be estimated as in Sec. F and after some algebra we obtain the following result,
In this case of hot Ohmic contacts one can replace the correlation function at temperature in the leading order with zero temperature case and introducing the dimensionless variable of integration, , we get
and the sub-leading correction is proportional to . The second integral is given by
References
- [1]S. Tewari, P. Rouleau, C. Grenier, F. Portier, A. Cavanna, U. Gennser, D. Mailly, and P. Roche, Phys. Rev. B 93, 035420 (2016).
- [2]R. Bisognin, A. Marguerite, B. Roussel, M. Kumar, C. Cabart, C. Chapdelaine, A. Mohammad-Djafari, J.-M. Berroir, E. Bocquillon, B. Plaçais, A. Cavanna, U. Gennser, Y. Jin, P. Degiovanni, and G. Fève, Nature Communications 10, 3379 (2019).
- [3]H. Duprez, E. Sivre, A. Anthore, A. Aassime, A. Cavanna, A. Ouerghi, U. Gennser, and F. Pierre, Phys. Rev. X 9, 021030 (2019).
- [4]R. Bhattacharyya, M. Banerjee, M. Heiblum, D. Mahalu, and V. Umansky, Phys. Rev. Lett. 122, 246801 (2019).
- [5]J. Nakamura, S. Liang, G. C. Gardner, and M. J. Manfra, Nature Physics 16, 931 (2020).
- [6]S. Jezouin, Z. Iftikhar, A. Anthore, F. D. Parmentier, U. Gennser, A. Cavanna, A. Ouerghi, I. P. Levkivskyi, E. Idrisov, E. V. Sukhorukov, L. I. Glazman, and F. Pierre, Nature 536, 58 (2016).
- [7]E. G. Idrisov, I. P. Levkivskyi, and E. V. Sukhorukov, Phys. Rev. B 96, 155408 (2017).
- [8]A. O. Slobodeniuk, I. P. Levkivskyi, and E. V. Sukhorukov, Phys. Rev. B 88, 165307 (2013).
- [9]E. Sivre, A. Anthore, F. D. Parmentier, A. Cavanna, U. Gennser, A. Ouerghi, Y. Jin, and F. Pierre, Nature Physics 14, 145 (2018).
- [10]C. Lin, M. Hashisaka, T. Akiho, K. Muraki, and T. Fujisawa, Nature Communications 12, 131 (2021).
- [11]E. Sivre, H. Duprez, A. Anthore, A. Aassime, F. D. Parmentier, A. Cavanna, A. Ouerghi, U. Gennser, and F. Pierre, Nature Communications 10, 5638 (2019).
- [12]C. Altimiras, H. le Sueur, U. Gennser, A. Cavanna, D. Mailly, and F. Pierre, Nature Physics 6, 34 (2010).
- [13]D. L. Kovrizhin and J. T. Chalker, Phys. Rev. Lett. 109, 106403 (2012).
- [14]I. P. Levkivskyi and E. V. Sukhorukov, Phys. Rev. B 85, 075309 (2012).
- [15]A. O. Slobodeniuk, E. G. Idrisov, and E. V. Sukhorukov, Phys. Rev. B 93, 035421 (2016).
- [16]K. Itoh, R. Nakazawa, T. Ota, M. Hashisaka, K. Muraki, and T. Fujisawa, Phys. Rev. Lett. 120, 197701 (2018).
- [17]C. Lin, R. Eguchi, M. Hashisaka, T. Akiho, K. Muraki, and T. Fujisawa, Phys. Rev. B 99, 195304 (2019).
- [18]R. H. Rodriguez, F. D. Parmentier, D. Ferraro, P. Roulleau, U. Gennser, A. Cavanna, M. Sassetti, F. Portier, D. Mailly, and P. Roche, Nature Communications 11, 2426 (2020).
- [19]C. Grenier, R. Hervé, G. Fève, and P. Degiovanni, Modern Physics Letters B 25, 1053 (2011).
- [20]T. Jullien, P. Roulleau, B. Roche, A. Cavanna, Y. Jin, and D. C. Glattli, Nature 514, 603 (2014).
- [21]C. Bäuerle, D. C. Glattli, T. Meunier, F. Portier, P. Roche, P. Roulleau, S. Takada, and X. Waintal, Reports on Progress in Physics 81, 056503 (2018).
- [22]J. D. Fletcher, N. Johnson, E. Locane, P. See, J. P. Griffiths, I. Farrer, D. A. Ritchie, P. W. Brouwer, V. Kashcheyevs, and M. Kataoka, Nature Communications 10, 5298 (2019).
- [23]C. Altimiras, H. le Sueur, U. Gennser, A. Cavanna, D. Mailly, and F. Pierre, Phys. Rev. Lett. 105, 226804 (2010).
- [24]H. le Sueur, C. Altimiras, U. Gennser, A. Cavanna, D. Mailly, and F. Pierre, Phys. Rev. Lett. 105, 056803 (2010).
- [25]I. P. Levkivskyi, Mesoscopic Quantum Hall Effect, 1st ed. (Springer-Verlag Berlin Heidelberg, 2012).DOI
- [26]S. Jezouin, F. D. Parmentier, A. Anthore, U. Gennser, A. Cavanna, Y. Jin, and F. Pierre, Science 342, 601 (2013).
- [27]Z. Iftikhar, Charge Quantization and Kondo Quantum Criticality in Few-Channel Mesoscopic Circuits, 1st ed. (Springer International Publishing, 2018).
- [28]A. A. Clerk, P. W. Brouwer, and V. Ambegaokar, Phys. Rev. Lett. 87, 186801 (2001).
- [29]E. G. Idrisov, I. P. Levkivskyi, and E. V. Sukhorukov, Phys. Rev. Lett. 121, 026802 (2018).
- [30]H. Duprez, E. Sivre, A. Anthore, A. Aassime, A. Cavanna, U. Gennser, and F. Pierre, Science 366, 1243 (2019).
- [31]Z. Iftikhar, S. Jezouin, A. Anthore, U. Gennser, F. D. Parmentier, A. Cavanna, and F. Pierre, Nature 526, 233 (2015).
- [32]Z. Iftikhar, A. Anthore, A. K. Mitchell, F. D. Parmentier, U. Gennser, A. Ouerghi, A. Cavanna, C. Mora, P. Simon, and F. Pierre, Science 360, 1315 (2018).
- [33]M. Banerjee, M. Heiblum, A. Rosenblatt, Y. Oreg, D. E. Feldman, A. Stern, and V. Umansky, Nature 545, 75 (2017).
- [34]M. Banerjee, M. Heiblum, V. Umansky, D. E. Feldman, Y. Oreg, and A. Stern, Nature 559, 205 (2018).
- [35]D. F. Mross, Y. Oreg, A. Stern, G. Margalit, and M. Heiblum, Phys. Rev. Lett. 121, 026801 (2018).
- [36]E. G. Idrisov, I. P. Levkivskyi, and E. V. Sukhorukov, Phys. Rev. B 101, 254526 (2020).
- [37]W. Pouse, L. Peeters, C. L. Hsueh, U. Gennser, A. Cavanna, M. A. Kastner, A. K. Mitchell, and D. Goldhaber-Gordon, Nature Physics 19, 492 (2023).
- [38]D. B. Karki, Phys. Rev. B 113, 155411 (2026).
- [39]D. B. Karki, Phys. Rev. B 111, 035426 (2025).
- [40]A. Rosenblatt, S. Konyzheva, F. Lafont, N. Schiller, J. Park, K. Snizhko, M. Heiblum, Y. Oreg, and V. Umansky, Phys. Rev. Lett. 125, 256803 (2020).
- [41]A. Zhang, G. Aissani, Q. Dong, Y. Jin, K. Watanabe, T. Taniguchi, C. Altimiras, P. Roche, J.-M. Berroir, F. Baudin, G. Fève, C. Ménard, O. Maillet, and F. D. Parmentier, Phys. Rev. Lett. 137, 146603 (2026).
- [42]A. Zhang, K. Watanabe, T. Taniguchi, P. Roche, C. Altimiras, F. D. Parmentier, and O. Maillet, Phys. Rev. Res. 7, L042037 (2025).
- [43]H. Duprez, F. Pierre, E. Sivre, A. Aassime, F. D. Parmentier, A. Cavanna, A. Ouerghi, U. Gennser, I. Safi, C. Mora, and A. Anthore, Phys. Rev. Res. 3, 023122 (2021).
- [44]A. K. Paul, P. Tiwari, R. Melcer, V. Umansky, and M. Heiblum, Phys. Rev. Lett. 133, 076601 (2024).
- [45]G. Le Breton, R. Delagrange, Y. Hong, M. Garg, K. Watanabe, T. Taniguchi, R. Ribeiro-Palau, P. Roulleau, P. Roche, and F. D. Parmentier, Phys. Rev. Lett. 129, 116803 (2022).
- [46]R. Kumar, S. K. Srivastav, U. Roy, U. Singhal, K. Watanabe, T. Taniguchi, V. Singh, P. Roulleau, and A. Das, Nature Physics 20, 1941 (2024).
- [47]S. Samai, D. Sarkar, A. Halder, T. Taniguchi, K. Watanabe, S. Mukerjee, S. K. Srivastav, and A. Das, (2026), arXiv:2607.19205 [cond-mat.mes-hall].arxiv.org/abs/2607.19205
- [48]X. G. Wen, Phys. Rev. B 41, 12838 (1990).
- [49]T. Giamarchi, Quantum Physics in One Dimension (Claverdon Press Oxford, 2004).
- [50]E. G. Idrisov, I. P. Levkivskyi, and E. V. Sukhorukov, Phys. Rev. B 106, L121405 (2022).
- [51]E. G. Idrisov, I. P. Levkivskyi, and E. V. Sukhorukov, Phys. Rev. Res. 7, 013042 (2025).
- [52]E. M. Lifshitz and L. P. Pitaevskii, Statistical Physics, Part 2: (Landau and Lifshitz Course of Theoretical Physics, Vol.9) (Butterworth-Heinemann Oxford, 1980).
- [53]See Supplemental Material at ... for calculation of contacts temperature, electron distribution function and noise of electric current.