WorksPhysics and Astronomy
Single-run determination of the saturation vapor pressure and enthalpy of vaporization/sublimation of a substance undergoing successive solid-solid and solid-liquid phase transitions: the case of -methyl acetamide
Abstract
We report on the dynamical measurement of the saturation vapor pressure of -methyl acetamide in the temperature range C to C. This is achieved by monitoring the pressure inside a vacuum chamber in which a precooled sample of the substance slowly thermalizes to the chamber temperature, undergoing first a phase transition between two crystalline structures around C and then a solid-liquid phase transition around C. Such a measurement provides in a single run accurate data for the saturation vapor pressure and the enthalpies of sublimation and vaporization of the different phases of the investigated substance.
Highlights
Single run-measurement of the saturation vapor pressure of a polymorphic substance undergoing solid-solid and solid-liquid phase transitions over an extended temperature range around room temperature
Accurate thermodynamics data for -methyl acetamide in its crI, crII and liquid phases in the range −30°C to 34°C
First determination of the saturation vapor pressure and enthalpy of sublimation for crII -methyl acetamide
Introduction
-methyl acetamide ()—the -methyl derivative of acetamide—benefits from a high dipole moment, low mass and low volatility and being amphiphilic. As such, it is widely used as a solvent Ash (1995), in the manufacturing of pharmaceuticals, pesticides, polymers and batteries Bernauer and Dohnal [3] and in electrochemistry applications Kirk, Othmer, Kroschwitz and Howe-Grant [8]. Due to the peptide bond, acetamides are also relevant possible interstellar indicators of the existence of life Halfen, Ilyushin and Ziurys [6].
-methyl acetamide (NMA) is solid at room temperature and has a melting phase transition temperature of °C. Interestingly, it is a polymorphic substance with two enantiotropic structures Katz and Post [7] and a phase transition (when heated) from crII to crI at °C.
The thermodynamics properties of -methyl acetamide around room temperature have been the focus of recent studies Zaitseva, Varfolomeev and Verevkin (2019a); Štejfa, Chun, Pokorný, Fulem and Růžička (2020), in which accurate data for the saturation vapor pressure (SVP) and the enthalpy of vaporization for liquid NMA and the enthalpy of sublimation for crI NMA have been reported.
In this work we make use of a newly established dynamical method Nielsen, Salimi, Andersen, Elm, Dantan and Pedersen (2024); Salimi, Pedersen, Andersen, Pedersen and Dantan (2025b) to accurately determine the SVP of a low-volatile substance by isolating it in a static vacuum chamber and monitoring the chamber pressure as the precooled substance slowly thermalizes to the higher chamber temperature. We apply this method to -methyl acetamide and show that it allows—in a single run—to accurately determine its SVP, and subsequently the enthalpies of sublimation/vaporization of the different phases, as it successively undergoes a solid-solid and a solid-liquid phase transition. This allows in particular to provide for the first time SVP and enthalpy of sublimation data for crII NMA in the range to °C.
Methods
Measurement procedure
The ASVAP experimental apparatus has been described in detail in Refs. Nielsen et al. (2024); Salimi et al. (2025b). It consists in three interconnected vacuum chambers: (i) a load chamber, in which the sample is inserted at room temperature and purified under low- and high-vacuum conditions, as will be detailed in the next section, (ii) a transfer chamber, in which the sample is precooled to a temperature well below room temperature (°C in the experiments reported here) under high vacuum conditions ( Pa), and (iii) an experimental chamber with a temperature stabilized at or above room temperature and in which a high vacuum ( Pa) has been realized prior to the insertion of the sample. The pressure in the experimental chamber is then monitored by means of an absolute pressure sensor (capacitive diaphragm BCEL7045 0.1 mbar, Edwards) under static vacuum conditions (outgassing rate of the chamber Pa/h at °C) as the sample slowly thermalizes to the chamber temperature (thermalization time h).
Two examples of the measured sample temperature and chamber pressure are shown in Figure 1: measurement 1 for an initial sample temperature of °C and a chamber temperature of °C and measurement 2 for an initial sample temperature of °C and a chamber temperature of °C. Exponential fits of the temperature variations in time yield time constants of s.
Figure 1. and as a function of time for measurement 1 (red, initial sample temperature of and chamber temperature of ) and measurement 2 (orange, initial sample temperature of and chamber temperature of ).
Purification
The -methyl acetamide sample was provided by Sigma-Aldrich/Merck with a certified purity of XXX%. Prior to
First Author et al.: Preprint submitted to Elsevier insertion in the load chamber the sample is heated slightly above the melting temperature and 2–3 mL are deposited in the sample holder in the load chamber slightly overpressurized with nitrogen. However, due to the relatively high hydrophilic nature of -methyl acetamide, the sample needs to be further purified after insertion. This is realized by performing repeated cycles of evacuation (active pumping with a scroll turbo pump and evaporative cooling) and reheating under static vacuum conditions (although in presence of an active vacuum gauge), whereby substances with a higher saturation vapor pressure (e.g. water) are gradually removed from the sample. A typical variation of pressure in the load chamber during purification is shown in Figure 2(a), where the peak pressure in the reheating phase is observed to decrease with the number of cycles and converges towards a constant value. Subsequent measurements of the experimental chamber pressure versus the sample temperature during thermalization with the experimental chamber temperature show that insufficient purification leads to an overestimation of the saturation vapor pressure, as is illustrated in Figure 2(b). The crII-crI phase transition around 1°C is in particular clearly visible for the vs curve corresponding to a short purification sequence (blue), which we surmize is due to the sudden release of water from the sample as the phase transition occurs. For a sufficiently long purification, though, and as long as the amount of sample remaining prior to the measurement in the experimental chamber is not vanishingly small, the experimentally measured vs curves reproducibly converge to the one represented by the red curve.
Figure 2. (a) Example of variation of the pressure in the load chamber under successive cycles of evacuation and static vacuum. (b) Examples of vs measurements after short (5 cycles, magenta) and long (22 cycles, red) purification sequences in the conditions corresponding to those of measurement 1.
Determination of the saturation vapor pressure
To determine the SVPs and enthalpies of -methyl acetamide in its different phases as a function of temperature, we follow the method described in Ref. Salimi et al. (2025b).
For an ideal gas, the temperature dependence of the SVP is given by the Clausius-Clapeyron equation Wark (1988)
where and are, respectively, the SVP and the enthalpy of vaporization/sublimation for the phase considered (), is Boltzmann’s constant and is Avogadro’s number. Since we are interested in taking into account the variation of the enthalpy of sublimation/vaporization with temperature in a limited temperature range around a given temperature . These variations are related to the difference in the heat capacities at constant pressure of the gas and solid/liquid phases, and , by
which can be well-approximated in the ranges considered by linear variations around Clarke and Glew [4]
where and are constants. Integrating this equation yields
where is the enthalpy of vaporization/sublimation at . Integrating Eq. (1) with the expression for given by Eq. (4) yields an expected variation of the saturation vapor pressure with temperature given by
where is the SVP at .
The values of and for the gaseous, liquid and crI phases can be obtained from linear interpolations of the values reported in the literature for the heat capacities at constant pressure Štefja et al. (2020), as shown in Figure 3. In absence of reported values for the crII heat capacity we use values extrapolated from the crI phase data.
Figure 3. Variation of the heat capacities versus temperature. The pink, magenta and grey thick lines show the values of the liquid, solid (crI) and gaseous heat capacities at constant pressure reported in the literature. The black dashed lines show the results of the linear interpolations used to determine and in the different temperature regions corresponding to the different phases. The vertical dashed lines show the positions of the phase transitions when increasing the temperature. The bottom horizontal black lines indicate the temperature ranges used in the experimental measurements 1 and 2.
The determination of the SVP and enthalpies of the different phases from the measured chamber pressure as a function of sample temperature is performed on the basis of a statistical rate theory (SRT) model for the evaporation and condensation flux from the sample, as performed in Nielsen et al. (2024); Salimi, Nielsen, Elm, Dantan and Pedersen (2025a); Salimi et al. (2025b) for liquids. As long as the sample thermalization time is much slower than the evaporation and condensation rates, the net particle flux can be assumed to be zero (steady state condition) at any time/temperature, from which the chamber pressure can be related to the SVP via the relation
where the characteristic function depends on the vibrational frequencies (), where DOF=30 is the number of vibrational degrees of freedom of the molecule.
This characteristic function can be determined numerically using the steady state flux condition and approximating the vibrational degrees of freedom as harmonic in the SRT model Nielsen et al. (2024). However, as shown in Salimi et al. (2025b), it can be advantageous to introduce an effective number of vibrational degrees of freedom, (), which can be determined from the knowledge of the gaseous heat capacity via
and which hence takes into account anharmonicities and conformal effects. The pressure in the chamber can then be phenomenologically modelled by an analytical expression corresponding to the steady state result of the SRT model with an effective DOF
The vs data can then be conveniently fitted in each temperature region with Eq. (8) using the previously determined values of , and and with and as free fitting parameters.
The uncertainties of the derived quantities are dominated by the uncertainties of the temperature and pressure readouts. The sample temperature is determined by a self-assembled sensor (type K, chromel-alumel), calibrated against a commercially available and accurate PT100 sensor (SE02, Pico Technology) with a final estimated accuracy . The specified pressure uncertainty for the pressure sensors is . The final uncertainties are reported with a deviation.
Results
Figure 4 shows the variation of the chamber pressure with the sample temperature during measurement 1, the vertical dashed lines indicating the crI–crII and crII–liquid phase transitions for an increasing temperature. The thin black lines show the results of fits with the analytical model (Eq. (8)) for each phase. As seen from the residuals, the model is observed to represent the data very well in each region.
Figure 4. (a) vs for measurement 1 (red), together with the results of fits with Eq. (8) for each phase (thin black lines). (b) Fit residuals.
The values for the SVP and enthalpies in each temperature range are shown as the dashed red and orange lines in Figure 5(a) and Figure 6. These values (and their uncertainties) can be readily computed via Eq. (5) from the values of and at , which are reported in Table 1 together with the values of and . The good consistency between the SVP and enthalpy values for the solid phases obtained in the two measurements with different chamber temperatures also indicates that only one phase is present at any time during the measurement, which would not be the case if, for instance, inhomogeneous melting or multi-crystalline structures occured progressively rather than abruptly at the phase transitions.
| Phase | Range | (K) | (kJ/mol) | (kJ/mol/K) | (Pa) | (kJ/mol) | ||
| Measurement 1<br> | crI | – | 264 | 6.4 | ||||
| crII | – | 294 | 7.0 | |||||
| Liquid | – | 307 | 7.5 | |||||
| Measurement 2<br> | crI | – | 264 | 6.2 | ||||
| crII | – | 294 | 6.9 |
Table 1. Summary of experimental conditions, estimated temperature variations for the enthalpies of sublimation/evaporization (, , , see Eq. (4)), effective number degrees of freedom (, see Eq. (7)), as well as the results of model fits (Eq. (8)) giving SVP () and enthalpies () for -methyl-acetamide. The fit results are given with a 1 (63%) confidence interval.

Figure 5. (a) vs for measurements 1 (red line) and 2 (orange line), together with previously reported results Gopal and Rizvi [5]; Kortüm and Biedersee [9]; Aucejo et al. [2]; Zaitseva et al. (2019a,b); Štejfa et al. (2020). (b) Relative deviation of the measured SVPs with respect to the Cox parametrization performed in Ref. Štejfa et al. (2020). The thin red lines show the confidence interval for measurement 1. The symbols show the results of Refs. Gopal and Rizvi [5]; Kortüm and Biedersee [9]; Aucejo et al. [2]; Zaitseva et al. (2019a,b); Štejfa et al. (2020).
Figure 6. Enthalpies of sublimation and vaporization for -methyl acetamide determined in this work for the three phases as a function of temperature. The single points with error bar indicate the used reference temperature () and show the confidence interval. The black dashed line shows the Cox parametrization of Ref. Štejfa et al. (2020). The symbols show the results of Refs. [9]; [11]; Starzewski et al. (1984); [2]; Roux et al. (1996); Štejfa et al. (2020), while the dashed lines indicate the results of Refs. [9]; [11]; [2], which are given as the Antoine parameterizations performed in Ref. MacKerell et al. [10].
We also observe good agreement between the SVPs and enthalpies for both crI and liquid phase determined in this work and those reported previously Gopal and Rizvi [5]; Kortüm and Biedersee [9]; Aucejo, Monton, Munoz and Sanchotello [2]; Zaitseva et al. (2019a); Zaitseva, Varfolomeev and Verevkin (2019b); Štejfa et al. (2020). The relative deviation with the Cox parametrization for the SVP reported in Štejfa et al. (2020) are shown in Figure 5(b). We also report for the first time values for the saturation vapor pressure and enthalpy of sublimation of -methyl acetamide crII in the range –. We observe a significantly lower value for the enthalpy of sublimation for the crII phase than for the more disordered crI phase.
Conclusion
We reported on the determination of the SVP of -methyl acetamide in the temperature range to and determined, in particular, for the first time the SVP and enthalpy of sublimation of crII NMA in the range –. In addition to providing new thermodynamical data for NMA this work demonstrates that it is possible to determine—in a single run—the SVP of a low-volatile substance over a broad temperature range, as it successively undergoes solid-solid and solid-liquid phase transitions. When combined with low pressure measurement capabilities as demonstrated in, e.g., Salimi et al. (2025b); Salimi, Nielsen, Pedersen and Dantan (2024), we expect the method to be applicable to a wide range of other polymorphic low-volatile substances, which will be the subject of future investigations.
CRediT authorship contribution statement
Mohsen Salimi: . Aurélien Dantan: . Henrik B. Pedersen: .
References
References
- [2]Aucejo, A., Monton, J.B., Munoz, R., Sanchetello, M., 1993. Isobaric vapor-liquid equilibrium data for the cyclohexanone + n-methylacetamide system. Journal of Chemical & Engineering Data 38, 160–162. URL: https://doi.org/10.1021/je00009a039, doi:10.1021/je00009a039, arXiv:https://doi.org/10.1021/je00009a039.
- [3]Bernauer, M., Dohnal, V., 2008. Temperature dependence of air-water partitioning of n-methylated (c1 and c2) fatty acid amides. Journal of Chemical and Engineering Data 53, 2622–2631. URL: https://doi.org/10.1021/je800517r, doi:10.1021/je800517r, arXiv:https://doi.org/10.1021/je800517r.
- [4]Clarke, E.C.W., Glew, D.N., 1966. Evaluation of thermodynamic functions from equilibrium constants. Trans. Faraday Soc. 62, 539–547. URL: http://dx.doi.org/10.1039/TF9666200539, doi:10.1039/TF9666200539.
- [5]Gopal, R., Rizvi, S.A., 1968. Vapour pressures of some mon- and di-alkyl substituted aliphatic amides at different temperatures. Journal of Indian Chemical Society 45, 13–16.DOI
- [6]Halfen, D.T., Ilyushin, V., Ziurys, L.M., 2011. Formation of peptide bonds in space: A comprehensive study of formamide and acetamide in sgr b2(n). The Astrophysical Journal 743, 60. URL: https://doi.org/10.1088/0004-637X/743/1/60, doi:10.1088/0004-637X/743/1/60.
- [7]Katz, J.L., Post, B., 1960. The crystal structure and polymorphism of N-methylacetamide. Acta Crystallographica 13, 624–628. URL: https://doi.org/10.1107/S0365110X60001485, doi:10.1107/S0365110X60001485.
- [8]Kirk, R.E., Othmer, D.F., Kroschwitz, J.I., Howe-Grant, M., 1991. Kirk-Othmer encyclopedia of chemical technology, vol. 1. Wiley, New York, NY.
- [9]Kortüm, G., Biedersee, H.v., 1970. Dampf/flüssigkeit-gleichgewichte (siedediagramme) binärer systeme hoher relativer flüchtigkeit. Chemie-Ing.-Tech. 42, 552–560.DOI
- [10]MacKerell, A.D.J., Shim, J.H., Anisimov, V.M., 2008. Re-evaluation of the reported experimental values of the heat of vaporization of n-methylacetamide. Journal of Chemical Theory and Computation 4, 1307–1312. URL: https://doi.org/10.1021/ct8000969, doi:10.1021/ct8000969, arXiv:https://doi.org/10.1021/ct8000969.
- [11]Manczinger, J., Kortüm, G., 1975. Thermodynamische mischungseffekte im system wasser(1)/n-methylacetamid(2). Zeitschrift für Physikalische Chemie Neue Folge 95, 177–186.DOI