betaFeedback

WorksPhysics and Astronomy

Atomic interferometry based on a phase-jump error signal with suppression of the lineshape-asymmetry-caused shift

Abstract

We develop a method for forming Ramsey fringes in atomic interferometers as a difference error signal using the phase-jump technique for Ramsey pulses (phase-jump error signal). In this case, the measurement procedure can be implemented as stabilization (locking) of the frequency chirp rate at the central zero of the error signal. We show analytically that this approach allows suppressing the lineshape-asymmetry-caused shift (LACS). This shift was recently theoretically predicted and experimentally identified in the papers [V. I. Yudin et al., JETP Lett. 122, 737 (2025); D. N. Kapusta et al., JETP Lett. 123, 388 (2026)]. A characteristic feature of the LACS is an inverse cubic dependence ∝1/T3\propto 1/T^3 (where TT is the time between adjacent Ramsey pulses), and it can become dominant for interferometers with a short baseline. Therefore, the developed measurement algorithm with a phase-jump error signal will enable significant improvement in the metrological performance of compact quantum sensors for various purposes (atomic gravimeters, accelerometers, gyroscopes).

Modern atom interferometry is a fundamental platform for developing a new generation of high-precision quantum sensors. After the first demonstration of a quantum gravimeter based on cold atom interference [1], this field has experienced rapid development, leading to the creation of devices with unprecedented sensitivity and long-term stability [2, 3, 4, 5]. A distinctive feature of such devices is the absence of the need for regular calibration, which makes them in highly demand both for fundamental research (testing the equivalence principle, measuring the gravitational constant) [6, 7, 8, 9, 10] and applied tasks, including geodesy, navigation, and monitoring of natural resources, etc. [11, 12, 13, 14, 15].

One of the key trends in the development of atom interferometers is their miniaturization and mobility. In this context, short-baseline (short-time-of-flight) interferometers offer a promising alternative. They are less susceptible to external perturbations, enable high sampling rates (up to tens of hertz), and open up broad possibilities for the creation of compact devices. As demonstrated in [16, 17, 18], even with a sequence duration on the order of a few milliseconds, it is possible to achieve metrological characteristics sufficient for most practical applications. This is facilitated by new methods for enhancing phase stability and interference signal contrast [19, 20, 21], as well as by efficient data processing algorithms [22, 23].

However, reducing the atomic transit time also gives rise to new systematic effects that previously had no significant impact. In our recent paper [24], we theoretically predicted a previously unknown lineshape-asymmetry-caused shift (LACS). A characteristic feature of this shift is its dependence ∝1/T3\propto1/T^3 on the time interval between pulses TT, making it dominant specifically in short-baseline interferometers and significantly limiting the accuracy of compact quantum sensors. This effect was experimentally identified in [25].

The present work is devoted to further theoretical analysis of the LACS shift in Mach-Zehnder atomic interferometers, as well as to the development of an effective method for its suppression. For this purpose, we compare two techniques for forming the difference error signal. In addition to the standard approach based on forming the error signal using the chirp-jump technique [26], we consider an alternative scheme using control of the phases of individual Ramsey pulses (phase-jump technique). It is shown analytically that the standard chirp-jump error signal method does not eliminate the LACS shift, whereas the use of a phase-jump error signal allows completely suppressing this shift, including when averaging over an arbitrary velocity distribution of atoms.

Below we will follow the mathematical formalism presented in [24]. As a specific scheme of an atomic interferometer, we consider a quantum gravimeter implemented on an atomic transition with unperturbed frequency ω0\omega_0, where ∣g⟩\lvert g\rangle and ∣e⟩\lvert e\rangle are the ground and excited states, respectively, to which the following column vectors correspond:

∣g⟩=(01),∣e⟩=(10).(1)|g\rangle= \begin{pmatrix} 0 \\ 1 \end{pmatrix}, \qquad|e\rangle= \begin{pmatrix} 1 \\ 0 \end{pmatrix}. \tag*{(1)}

In this two-level atom, the transition ∣g⟩↔∣e⟩|g\rangle\leftrightarrow|e\rangle is induced under the action of a resonant interaction operator of the type of a plane traveling wave with wave vector keff\mathbf{k}_{\mathrm{eff}}

V^(t,r)=−ℏΩ02e−i[ωt+αt2/2−(r⋅keff)+ϕ]∣e⟩⟨g∣+h.c.,(2)\hat{V}(t,\mathbf{r})=-\frac{\hbar\Omega_0}{2}e^{-i[\omega t+\alpha t^2/2-(\mathbf{r}\cdot\mathbf{k}_{\mathrm{eff}})+\phi]}|e\rangle\langle g|+h.c., \tag*{(2)}

where ω\omega is the carrier frequency, which can be varied near the transition frequency ω0\omega_0; α\alpha is the rate of a frequency chirp; ϕ\phi is the additional phase, which we can control; and Ω0>0\Omega_0>0 is the real Rabi frequency of the induced transitions. As is known, in such an interferometric scheme, the quantity (g⋅keff)(\mathbf{g}\cdot\mathbf{k}_{\mathrm{eff}}) is measured, where g\mathbf{g} is the gravitational acceleration.

Note that the type of interaction (2) takes place both for one-photon transitions under the action of a resonant traveling light wave in the case of an optical transition ∣g⟩↔∣e⟩|g\rangle\leftrightarrow|e\rangle, and for two-photon transitions in a bichromatic field of two counter-propagating traveling light waves, when the difference of the optical frequencies of these waves (ω1−ω2)(\omega_1-\omega_2) varies near the microwave frequency ω0\omega_0 in the case of a transition between hyperfine levels in the ground state (for example, in alkali metal atoms). However, this does not matter for our consideration.

Let us consider a Mach-Zehnder atomic interferometer-gravimeter based on a sequence of three Ramsey pulses, shown in Figure 1. In the reference frame of an atom moving along a classical trajectory, operator (2) can be formally represented as

Figure 1. Standard scheme of a Mach-Zehnder type atomic interferometer-gravimeter.

V^(atom)=−ℏΩ02e−iφ(t)∣e⟩⟨g∣+h.c.,(3)\hat{V}^{(\mathrm{atom})}=-\frac{\hbar\Omega_0}{2}e^{-i\varphi(t)}|e\rangle\langle g|+h.c., \tag*{(3)}

with a time-dependent phase, φ(t)\varphi(t). Then, for sufficiently short durations of the Ramsey pulses, the evolution operator of the atom in the basis (1) under the action of the jj-th Ramsey pulse can be written as

R^(j)=(AjiBje−iφ(tj)iBjeiφ(tj)Aj∗),(4)\hat{R}^{(j)}=\begin{pmatrix} A_j & iB_je^{-i\varphi(t_j)} \\ iB_je^{i\varphi(t_j)} & A_j^* \end{pmatrix}, \tag*{(4)}

where tjt_j is the time of action of the jj-th Ramsey pulse (see Figure 1). The matrix elements in (4) are determined as follows

Aj=cos⁡(Ω(j)τj2)+iδjΩ(j)sin⁡(Ω(j)τj2),A_j=\cos\left(\frac{\Omega^{(j)}\tau_j}{2}\right)+i\frac{\delta_j}{\Omega^{(j)}}\sin\left(\frac{\Omega^{(j)}\tau_j}{2}\right),
Bj=Ω0Ω(j)sin⁡(Ω(j)τj2),B_j=\frac{\Omega_0}{\Omega^{(j)}}\sin\left(\frac{\Omega^{(j)}\tau_j}{2}\right),
Ω(j)=Ω02+δj2,(5)\Omega^{(j)}=\sqrt{\Omega_0^2+\delta_j^2}, \tag*{(5)}

where τj\tau_j is the duration of the jj-th pulse, δj\delta_j is the effective detuning of perturbation (3) from resonance during the action of the jj-th pulse from the point of view of the moving atom, Ω(j)\Omega^{(j)} is the generalized Rabi frequency during the action of the jj-th pulse. Note that BjB_j is a real number.

Let us consider the usual scheme of atom interrogation in the case of a spatially homogeneous gravitational acceleration g\mathbf{g}, when at time t=0t=0 (i.e., at the beginning of the action of the 1st Ramsey pulse, see Figure 1) the atom are in the lower state ∣g⟩|g\rangle and have an initial velocity v\mathbf{v}. Then, as the spectroscopic signal after the action of the Ramsey sequence in Figure 1, we will consider the total population NeN_e of atoms in the upper level ∣e⟩|e\rangle on three different trajectories: 1e1e, 2e2e and 3e3e (see red solid lines in Figure 1). Assuming that after the action of three Ramsey pulses all three trajectories have diverged to distances noticeably larger than the de Broglie wavelength, we have the following expression

Ne=n1e+n2e+n3e=∣K1e∣2+∣K2e∣2+∣K3e∣2.(6)N_e=n_{1e}+n_{2e}+n_{3e}=|K_{1e}|^2+|K_{2e}|^2+|K_{3e}|^2. \tag*{(6)}

Using the notation from (4), we can write

K1e=B1A2A3,K2e=B1B2B3−A1∗B2A3eiα~T2eiϕ,K3e=A1∗A2∗B3,(7)\begin{aligned} K_{1e}&=B_1A_2A_3,\\ K_{2e}&=B_1B_2B_3-A_1^*B_2A_3e^{i\widetilde{\alpha}T^2}e^{i\phi},\\ K_{3e}&=A_1^*A_2^*B_3, \tag*{(7)} \end{aligned}

where TT is the free evolution time between pulses, and α~\widetilde{\alpha} is the frequency chirp rate centered on the measured quantity (g⋅keff)(\mathbf{g}\cdot\mathbf{k}_{\mathrm{eff}})

α~=α−(g⋅keff).(8)\widetilde{\alpha}=\alpha-(\mathbf{g}\cdot\mathbf{k}_{\mathrm{eff}}). \tag*{(8)}

In the standard interrogation scheme, we have the following expressions for the duration and one-photon detuning of each pulse

τ1=τ3=τ,τ2=2τ,\tau_1=\tau_3=\tau,\qquad\tau_2=2\tau,
δ1=ΔD,δ2=α~T+ΔD,δ3=2α~T+ΔD,(9)\delta_1=\Delta_D,\qquad\delta_2=\widetilde{\alpha}T+\Delta_D,\qquad\delta_3=2\widetilde{\alpha}T+\Delta_D, \tag*{(9)}

where ΔD\Delta_D is the residual Doppler detuning from resonance during the action of each pulse, which, taking into account the recoil effect for atoms with mass MM, has the following standard form

ΔD=ω−ω0−ℏ∣keff∣22M−(v⋅keff)−δˉac,(10)\Delta_{\mathrm{D}} = \omega- \omega_0 - \frac{\hbar\lvert\mathbf{k}_{\mathrm{eff}} \rvert^2}{2M} - \left(\mathbf{v} \cdot\mathbf{k}_{\mathrm{eff}}\right) - \bar{\delta}_{\mathrm{ac}}, \tag*{(10)}

where (v⋅keff)\left(\mathbf{v} \cdot\mathbf{k}_{\mathrm{eff}}\right) is the Doppler frequency shift during the action of the 1st Ramsey pulse at t=0t=0 (see Figure 1). In (10), we also took into account the Stark shift δˉac\bar{\delta}_{\mathrm{ac}} of the atomic transition frequency caused by the probe light field, and which we assume to be the same for all three pulses.

In addition, in contrast to [24], for our further purposes we introduced additional (artificial) phases of the pulses ϕ1\phi_1, ϕ2\phi_2 and ϕ3\phi_3 (see Figure 1), which we can control individually for each Ramsey pulse. These phases determine the parameter Φ\Phi:

Φ=ϕ1+ϕ3−2ϕ2,(11)\Phi= \phi_1 + \phi_3 - 2\phi_2, \tag*{(11)}

which is contained in the additional phase factor eiΦe^{i\Phi} in the expression for K2eK_{2e} in (7).

The functional dependence of the spectroscopic signal Ne(α~,Φ)N_e(\tilde{\alpha}, \Phi) on the varied parameter α~\tilde{\alpha} at the fixed Φ\Phi can be represented as

Ne(α~,Φ)=∣K1e(α~)∣2+∣K2e(α~,Φ)∣2+∣K3e(α~)∣2,(12)N_e(\tilde{\alpha}, \Phi) = \lvert K_{1e}(\tilde{\alpha}) \rvert^2 + \lvert K_{2e}(\tilde{\alpha}, \Phi) \rvert^2 + \lvert K_{3e}(\tilde{\alpha}) \rvert^2, \tag*{(12)}

where we took into account the phase insensitivity (with respect to phase Φ\Phi) of the two contributions ∣K1e(α~)∣2\lvert K_{1e}(\tilde{\alpha}) \rvert^2 and ∣K3e(α~)∣2\lvert K_{3e}(\tilde{\alpha}) \rvert^2. In the general case, the spectral dependence Ne(α~,Φ)N_e(\tilde{\alpha}, \Phi) on the variable α~\tilde{\alpha} represents a sequence of narrow Ramsey resonances with FWHM about π/T2\pi/T^2 with a flat envelope (width of the order of ∼2Ω0/T\sim2\Omega_0/T), which is described by the interference contribution ∣K2e(α~,Φ)∣2\lvert K_{2e}(\tilde{\alpha}, \Phi) \rvert^2 in (12). In addition, there is also a broad substrate with a flat dependence (width of the order of ∼2Ω0/T\sim2\Omega_0/T), to which the other two terms ∣K1e(α~)∣2\lvert K_{1e}(\tilde{\alpha}) \rvert^2 and ∣K3e(α~)∣2\lvert K_{3e}(\tilde{\alpha}) \rvert^2 contribute.

In [24], we considered the usual case of equal phases of all three pulses ϕ1=ϕ2=ϕ3\phi_1=\phi_2=\phi_3 (i.e., Φ=0\Phi=0), when the gravimetric measurement of the quantity (g⋅keff)(\mathbf{g} \cdot\mathbf{k}_{\mathrm{eff}}) corresponds to the position of the top of the central Ramsey resonance in the dependence Ne(α~,0)N_e(\tilde{\alpha},0). As a result, in [24], the lineshape-asymmetry-caused shift (LACS) was found in the case of ΔD≠0\Delta_{\mathrm{D}} \ne0. It was shown that this shift is proportional to 1/T31/T^3 and it can become dominant for short-baseline interferometers.

However, in addition to gravimetric measurements based on the position of the top of the central Ramsey resonance, another algorithm proposed in [26] is also used. As applied to our formulation of the problem, the essence of the approach [26] can be expressed as the formation of an error signal Serrchirp−jmp(α~)S_{\mathrm{err}}^{\mathrm{chirp-jmp}}(\tilde{\alpha}) by subtracting measurements at two points α~±Δα\tilde{\alpha}\pm\Delta\alpha (i.e., using the chirp-jump technique):

Serrchirp−jmp(α~)=Ne(α~+Δα,0)−Ne(α~−Δα,0),(13)S_{\mathrm{err}}^{\mathrm{chirp-jmp}}(\tilde{\alpha}) = N_e(\tilde{\alpha}+\Delta\alpha,0) - N_e(\tilde{\alpha}-\Delta\alpha,0), \tag*{(13)}

where Δα\Delta\alpha is some fixed value of the chirp-rate jump. We will call such a difference signal as a chirp-jump error signal. The dispersive lineshape of the error signal

Serrchirp−jmp(α~)S_{\mathrm{err}}^{\mathrm{chirp-jmp}}(\tilde{\alpha}) is presented in Figure 2. In this case, the gravimetric measurement is determined by the position of the central zero, which is found from the equation Serrchirp−jmp(α~)=0S_{\mathrm{err}}^{\mathrm{chirp-jmp}}(\tilde{\alpha})=0. To maximize the slope at the center of the dispersion curve, one should use the value Δα=0.5π/T2\Delta\alpha=0.5\pi/T^2 for the chirp-rate jump.

Figure 2. Demonstration of the shift in the position of the central zero for the chirp-jump error signal (for ΔD≠0\Delta_{\mathrm{D}} \ne0).

Using the symmetry analysis developed in [24], it is not difficult to show that a shift also appears in the gravimetric measurement using Serrchirp−jmp(α~)S_{\mathrm{err}}^{\mathrm{chirp-jmp}}(\tilde{\alpha}) in the presence of the residual Doppler shift ΔD≠0\Delta_{\mathrm{D}}\ne0. Indeed, let us consider the error signal (13) at the point α~=0\tilde{\alpha}=0:

Serrchirp−jmp(0)=Ne(Δα,0)−Ne(−Δα,0).(14)S_{\mathrm{err}}^{\mathrm{chirp-jmp}}(0) = N_e(\Delta\alpha,0) - N_e(-\Delta\alpha,0). \tag*{(14)}

Then, as follows from [24], where the asymmetry of the resonance Ne(α~,0)≠Ne(−α~,0)N_e(\tilde{\alpha},0)\ne N_e(-\tilde{\alpha},0) was shown for ΔD≠0\Delta_{\mathrm{D}}\ne0, we obtain Serrchirp−jmp(0)≠0S_{\mathrm{err}}^{\mathrm{chirp-jmp}}(0)\ne0 for ΔD≠0\Delta_{\mathrm{D}}\ne0. Consequently, the zero of the error signal is located at the point α~=ΔLACSchirp−jmp≠0\tilde{\alpha}=\Delta_{\mathrm{LACS}}^{\mathrm{chirp-jmp}}\ne0 (see Figure 2). In this case, the shift ΔLACSchirp−jmp\Delta_{\mathrm{LACS}}^{\mathrm{chirp-jmp}} also depends on the value of Δα\Delta\alpha and may differ noticeably from the shift in [24]. Numerical calculations show that for Ω0τ=π/2\Omega_0\tau=\pi/2 the LACS shift is described rather well by the expression

ΔLACSchirp−jmp≈η1(T/τ,T2Δα)TT3ΔDΩ0,(15)\Delta_{\mathrm{LACS}}^{\mathrm{chirp-jmp}} \approx\eta_1(T/\tau,T^2\Delta\alpha)\frac{T}{T^3}\frac{\Delta_{\mathrm{D}}}{\Omega_0}, \tag*{(15)}

where the dimensionless function η1(T/τ,T2Δα)\eta_1(T/\tau,T^2\Delta\alpha) depends on two dimensionless parameters: T/τT/\tau and T2ΔαT^2\Delta\alpha. The forms of this function for several values of T2ΔαT^2\Delta\alpha are presented in Figure 3(a) in the region T≫τT\gg\tau. It is interesting to note that for a mono-velocity atomic ensemble, the magnitude and sign of the shift substantially depend on the magnitude of Δα\Delta\alpha. At the same time, for the optimal value Δα=0.5π/T2\Delta\alpha=0.5\pi/T^2, the LACS shift becomes relatively small [see the red line in Figure 3(a)].

Figure 3. (a) Dependence η1(T/τ,T2Δα)\eta_1(T/\tau,T^2\Delta\alpha) on the dimensionless parameter T/τT/\tau in the expression (15) for several fixed values of the chirp jump T2Δα=0,π/4,π/2,2π/3T^2\Delta\alpha=0,\pi/4,\pi/2,2\pi/3 (from bottom to top) in the case of Ω0τ=π/2\Omega_0\tau=\pi/2. (b) Dependence of the dimensionless function η2(T/τ,∣keff∣vˉ/Ω0)\eta_2(T/\tau,|\mathbf{k}_{\rm eff}|\bar{v}/\Omega_0) on T/τT/\tau in the expression (19) for several fixed values ∣keff∣vˉ/Ω0=5,10,40,100|\mathbf{k}_{\rm eff}|\bar{v}/\Omega_0=5,10,40,100 (from bottom to top) for Ω0τ=π/2\Omega_0\tau=\pi/2 and Δα=0.5π/T2\Delta\alpha=0.5\pi/T^2.

In the case of a non-mono-velocity atomic ensemble, instead of (13), one should use the expression for the error signal averaged over the velocity distribution f(v)f(\mathbf{v})

Serrchirp−jump(α~)=⟨Ne(α~+Δα,0)⟩v−⟨Ne(α~−Δα,0)⟩v,(16)S_{\rm err}^{\rm chirp-jump}(\tilde{\alpha})=\left\langle N_e(\tilde{\alpha}+\Delta\alpha,0)\right\rangle_{\mathbf{v}}-\left\langle N_e(\tilde{\alpha}-\Delta\alpha,0)\right\rangle_{\mathbf{v}}, \tag*{(16)}

where the symbol ⟨W⟩v\langle W\rangle_{\mathbf{v}} means:

⟨W⟩v=∫Wf(v) dv.(17)\langle W\rangle_{\mathbf{v}}=\int W f(\mathbf{v})\,d\mathbf{v}. \tag*{(17)}

Below in the calculations we will consider a Maxwellian velocity distribution

fM(v)=1π3/2vˉ3e−(v−v0)2vˉ2,(18)f_M(\mathbf{v})=\frac{1}{\pi^{3/2}\bar{v}^{3}}e^{-\frac{(\mathbf{v}-\mathbf{v}_0)^2}{\bar{v}^{2}}}, \tag*{(18)}

where vˉ\bar{v} is the characteristic width of the velocity distribution relative to the mean velocity of atoms v0\mathbf{v}_0.

In this case, the magnitude of the LACS undergoes substantial changes. For example, as numerical calculations show, for Ω0τ=π/2\Omega_0\tau=\pi/2 and a phase jump Δα=0.5π/T2\Delta\alpha=0.5\pi/T^2 in the case when the Doppler width ∣keff∣vˉ|\mathbf{k}_{\rm eff}|\bar{v} substantially exceeds the Rabi frequency (∣keff∣vˉ>5Ω0|\mathbf{k}_{\rm eff}|\bar{v}>5\Omega_0), the following expression works well

ΔLACSchirp−jump≈η2(T/τ,∣keff∣vˉ/Ω0)τT3Ω0∣keff∣vˉ⟨ΔD⟩v∣keff∣vˉ,(19)\Delta_{\rm LACS}^{\rm chirp-jump} \approx\eta_2(T/\tau,|\mathbf{k}_{\rm eff}|\bar{v}/\Omega_0)\frac{\tau}{T^3}\frac{\Omega_0}{|\mathbf{k}_{\rm eff}|\bar{v}}\frac{\langle\Delta_D\rangle_{\mathbf{v}}}{|\mathbf{k}_{\rm eff}|\bar{v}}, \tag*{(19)}

where

⟨ΔD⟩v=ω−ω0−ℏ∣keff∣22M−(v0⋅keff)−δˉac,(20)\langle\Delta_D\rangle_{\mathbf{v}}=\omega-\omega_0-\frac{\hbar|\mathbf{k}_{\rm eff}|^2}{2M}-(\mathbf{v}_0\cdot\mathbf{k}_{\rm eff})-\bar{\delta}_{\rm ac}, \tag*{(20)}

is the Doppler detuning for atoms with the mean velocity v0\mathbf{v}_0 in the ensemble. The dimensionless function η2(T/τ,∣keff∣vˉ/Ω0)\eta_2(T/\tau,|\mathbf{k}_{\rm eff}|\bar{v}/\Omega_0) in (19) depends rather slowly on the two dimensionless parameters T/τT/\tau and ∣keff∣vˉ/Ω0|\mathbf{k}_{\rm eff}|\bar{v}/\Omega_0 [see Figure 3(b)].

Thus, for the chirp-jump error signal, the LACS shift is also existing, which is proportional to 1/T31/T^3 (as well as in [24]). Its metrological significance on the example of atomic interferometer-gravimeters was estimated in [24, 25].

In the present paper, to suppress the LACS shift, we propose an alternative method of forming the error signal. For this, we will artificially change the phase of one of the pulses (for example, the third) relative to the other two so that a phase parameter Φ≠0\Phi\ne0 appears for K2e(α~,Φ)K_{2e}(\tilde{\alpha},\Phi) in the expression (7). Then we can form the following error signal based on the difference of two signals with opposite phases ±Φ\pm\Phi:

Serrphase−jump(α~)=Ne(α~,Φ)−Ne(α~,−Φ)=∣K2e(α~,Φ)∣2−∣K2e(α~,−Φ)∣2,(21)S_{\rm err}^{\rm phase-jump}(\tilde{\alpha})=N_e(\tilde{\alpha},\Phi)-N_e(\tilde{\alpha},-\Phi)=|K_{2e}(\tilde{\alpha},\Phi)|^2-|K_{2e}(\tilde{\alpha},-\Phi)|^2, \tag*{(21)}

where, in accordance with expression (12), we took into account that the terms ∣K1e(α~)∣2|K_{1e}(\tilde{\alpha})|^2 and ∣K3e(α~)∣2|K_{3e}(\tilde{\alpha})|^2 do not depend on the phase Φ\Phi. The differential signal (21) we will call as the phase-jump error signal. In this case, the gravimetric measurement is also determined by the position of the central zero, which is determined from the equation Serrphase−jump(α~)=0S_{\rm err}^{\rm phase-jump}(\tilde{\alpha})=0.

Let us show that, in contrast to the chirp-jump error signal Serrchirp−jump(α~)S_{\rm err}^{\rm chirp-jump}(\tilde{\alpha}), the phase-jump error signal Serrphase−jump(α~)S_{\rm err}^{\rm phase-jump}(\tilde{\alpha}) does not experience a shift even in the case of ΔD≠0\Delta_D\ne0, i.e., ΔLACSphase−jump=0\Delta_{\rm LACS}^{\rm phase-jump}=0. Indeed, let us consider the error signal at the point α~=0\tilde{\alpha}=0:

Serrphase−jump(0)=∣K2e(0,Φ)∣2−∣K2e(0,−Φ)∣2.(22)S_{\rm err}^{\rm phase-jump}(0)=|K_{2e}(0,\Phi)|^2-|K_{2e}(0,-\Phi)|^2. \tag*{(22)}

Since, as follows from (9), at α~=0\tilde{\alpha}=0 the first and third detunings are equal, δ1=δ3\delta_1=\delta_3, then, in accordance with definition (5), the equality for the matrix elements A1=A3A_1=A_3 holds for an arbitrary value of Ω0τ\Omega_0\tau. As a result, based on (7), we can write the following expressions

K2e(0,Φ)=B1B2B3−B2∣A3∣2eiΦ,K2e(0,−Φ)=B1B2B3−B2∣A3∣2e−iΦ,(23)\begin{aligned} K_{2e}(0,\Phi)&=B_1B_2B_3-B_2|A_3|^2e^{i\Phi},\\ K_{2e}(0,-\Phi)&=B_1B_2B_3-B_2|A_3|^2e^{-i\Phi}, \tag*{(23)} \end{aligned}

in which all coefficients are real, except for the phase factors e±iΦe^{\pm i\Phi}. Thus, the equality K2e(0,−Φ)=K2e∗(0,Φ)K_{2e}(0,-\Phi)=K_{2e}^{*}(0,\Phi) holds, which in expression (22) automatically leads to the result

Serrphase−jump(0)=0,(24)S_{\rm err}^{\rm phase-jump}(0)=0, \tag*{(24)}

for any ΔD≠0\Delta_D\ne0, Ω0τ\Omega_0\tau and Φ\Phi, i.e., the LACS is completely absent. For example, Figure 4(a) shows the calculation of Serrphase−jump(α~)S_{\rm err}^{\rm phase-jump}(\tilde{\alpha}) for various values of the residual Doppler detuning ΔD\Delta_D. For comparison, Figure 4(b) shows the calculation of the chirp-jump error signal Serrchirp−jump(α~)S_{\rm err}^{\rm chirp-jump}(\tilde{\alpha}) for the same values of ΔD\Delta_D. As can be seen, the shapes of the signals Serrphase−jump(α~)S_{\rm err}^{\rm phase-jump}(\tilde{\alpha}) and Serrchirp−jump(α~)S_{\rm err}^{\rm chirp-jump}(\tilde{\alpha}) are almost identical, except for the presence of the LACS shift in the center for the chirp-jump error signal in Figure 4(b).

Figure 4. Error signals: (a) Serrphase−jmp(α~)S_{\mathrm{err}}^{\mathrm{phase-jmp}}(\widetilde{\alpha}) for Φ=π/2\Phi= \pi/2; (b) Serrchirp−jmp(α~)S_{\mathrm{err}}^{\mathrm{chirp-jmp}}(\widetilde{\alpha}) for Δα=0.5π/T2\Delta\alpha= 0.5\pi/T^{2}. Calculations were performed for various values of ΔD\Delta_D: ΔD=0\Delta_D = 0 (blue line), ΔD/Ω0=0.5\Delta_D/\Omega_0 = 0.5 (green line), ΔD/Ω0=1\Delta_D/\Omega_0 = 1 (red line). Calculation parameters: Ω0τ=π/2\Omega_0\tau= \pi/2, T=10τT = 10\tau.

It should be noted that the phase-jump error signal (21) contains a contribution only from atoms on trajectory 2e2e (see Figure 1), on which the interference pattern is formed. While the chirp-jump error signal (13) contains also a contribution from the broad substrate (which is, in the general case, asymmetric in α~\widetilde{\alpha}, see [24]), formed by atoms on trajectories 1e1e and 3e3e (see Figure 1).

The independence of equality (24) from the values of ΔD\Delta_D means the independence from the magnitude of the Doppler shift (v⋅keff\mathbf{v}\cdot\mathbf{k}_{\mathrm{eff}}), which, in turn, means that the equality

⟨Serrphase−jmp(0)⟩v=0,(25)\left\langle S_{\mathrm{err}}^{\mathrm{phase-jmp}}(0)\right\rangle_{\mathbf{v}} = 0, \tag*{(25)}

also holds for the velocity-averaged error signal with any velocity distribution f(v)f(\mathbf{v}) (i.e., not only for (18)). Thus ⟨ΔLACSphase−jmp⟩v=0\left\langle\Delta_{\mathrm{LACS}}^{\mathrm{phase-jmp}}\right\rangle_{\mathbf{v}} = 0 for arbitrary ⟨ΔD⟩v≠0\left\langle\Delta_D\right\rangle_{\mathbf{v}} \ne0, Ω0τ\Omega_0\tau, and Φ\Phi.

Note that the maximal slope of the error signal at the center of the line is achieved at Φ=π/2\Phi= \pi/2. At the same time, from a theoretical point of view, it is completely unimportant how the formation of phase jumps ±Φ\pm\Phi is carried out. However, from a practical viewpoint, it seems most convenient to apply phase jumps ϕ3=±π/2\phi_3 = \pm\pi/2 for the third pulse at ϕ1=ϕ2=0\phi_1 = \phi_2 = 0 (see Figure 1).

Thus, the use of a phase-jump error signal allows suppressing the LACS regardless of the velocity distribution of atoms. This can significantly improve the metrological characteristics of small-sized atomic interferometers with a short baseline, without reducing the sensitivity of measurements.

As for other systematic shifts that appear in real experiments due to various deviations from the considered ideal interferometer scheme (spatial inhomogeneity of light and magnetic fields, imperfection of pulse shapes, etc.), the phase-jump and chirp-jump techniques are approximately identical with respect to them.

In conclusion, we have continued the theoretical study of the systematic lineshape-asymmetry-caused shift (LACS), predicted in [24] for Mach-Zehnder atomic interferometers. Two approaches to the measurement procedure based on the formation of an error signal were analyzed. In the case of the standard chirp-jump technique, it is shown that the LACS is preserved and has the same dependence ∝1/T3\propto1/T^3.

The key result of the work is the proposal and justification of an alternative method for forming the error signal based on controlled phase jumps (phase-jump error signal). In contrast to the standard chirp-jump approach [26], the proposed error signal is formed by subtracting signals obtained at two opposite values of the artificial phase (±Φ\pm\Phi). It is analytically proven that for such an error signal, the position of the central zero does not depend on the Doppler detuning and, consequently, on the lineshape asymmetry. This also holds when averaging over an arbitrary velocity distribution of atoms. Thus, the use of a phase-jump error signal allows suppressing the LACS shift, that cannot be achieved using the standard chirp-jump error signal.

It is important to note that the proposed method does not require modification of the hardware part of the interferometer and can be implemented only at the level of the algorithm for controlling the phases of the Ramsey pulses. In this case, the maximum slope of the dispersion curve of the error signal is achieved at Φ=π/2\Phi= \pi/2, which ensures optimal measurement sensitivity.

The obtained results are of immediate significance for the development of small-sized atomic interferometers for various purposes (gravimeters, accelerometers, and gyroscopes). Suppression of the LACS shift can significantly improve their metrological characteristics, especially in conditions where the atomic transit time is limited by requirements of compactness and speed. The developed approach can also be extended to other configurations of atomic interferometers and coherent systems where the asymmetry of spectral lines plays a noticeable role.

Further research should focus on the experimental implementation of the proposed method, as well as on evaluating its robustness to other types of systematic errors and to the limiting parameters of the equipment used.

References

  1. [1]M. Kasevich and S. Chu, “Atomic interferometry using stimulated Raman transitions”, Phys. Rev. Lett. 67, 181 (1991).
  2. [2]A. Peters, K. Y. Chung, S. Chu, “High-precision gravity measurements using atom interferometry”, Metrologia 38, 25 (2001).
  3. [3]C. Freier, M. Hauth, V. Schkolnik, B. Leykauf, M. Schilling, H. Wziontek, H.-G. Scherneck, J. Müller, and A. Peters, “Mobile quantum gravity sensor with unprecedented stability”, J. Phys.: Conf. Ser. 723, 012050 (2016).
  4. [4]V. Ménoret, P. Vermeulen, N. Le Moigne, S. Bonvalot, P. Bouyer, A. Landragin, and B. Desruelle, “Gravity measurements below 10−9 g with a transportable absolute quantum gravimeter”, Sci. Rep. 8, 12300 (2018).
  5. [5]N. Heine, J. Matthias, M. Sahelgozin, W. Herr, S. Abend, L. Timmen, J. Müller, and E. M. Rasel, “A transportable quantum gravimeter employing delta-kick collimated Bose-Einstein condensates”, Eur. Phys. J. D 74, 174 (2020).DOI
  6. [6]A. Wicht, J. M. Hensley, E. Sarajlic, and S. Chu, “A Preliminary Measurement of the Fine Structure Constant Based on Atom Interferometry”, Phys. Scr. 102, 82 (2002).
  7. [7]G. Rosi, F. Sorrentino, L. Cacciapuoti, F. Sorrentino, M. Prevedelli, M. Zych, C. Brukner, and G. M. Tino, “Quantum test of the equivalence principle for atoms in coherent superposition of internal energy states”, Nature 510, 518 (2014).
  8. [8]X.-C. Duan, X.-B. Deng, M.-K. Zhou, K. Zhang, W.-J. Xu, F. Xiong, Y.-Y. Xu, C.-G. Shao, J. Luo, and Z.-K. Hu, “Test of the Universality of Free Fall with Atoms in Different Spin Orientations”, Phys. Rev. Lett. 117, 023001 (2016).DOI
  9. [9]P. Asenbaum, C. Overstreet, M. Kim, J. Curti, and M. A. Kasevich, “Atom-Interferometric Test of the Equivalence Principle at the 10−12 Level”, Phys. Rev. Lett. 125, 191101 (2020).DOI
  10. [10]L. Zhou, S. T. Yan, Y. H. Ji, C. He, J. J. Jiang, Z. Hou, R. D. Xu, Q. Wang, Z. X. Li, D. F. Gao, M. Liu, W. T. Ni, J. Wang, and M. S. Zhan, “Toward a high-precision mass-energy test of the equivalence principle with atom interferometers”, Front. Phys. 10, 1039119 (2022).DOI
  11. [11]J. Kennedy, T. P. A. Ferré, B. Creutzfeldt, “Time-lapse gravity data for monitoring and modeling artificial recharge through a thick unsaturated zone”, Water Resour. Res. 52, 7244-7261 (2016).DOI
  12. [12]Y. Bidel, N. Zahzam, C. Blanchard, A. Bonnin, M. Cadoret, A. Bresson, D. Rouxel, and M. F. Lequentrec-Lalancette, “Absolute marine gravimetry with matter-wave interferometry”, Nat. Commun. 9, 627 (2018).DOI
  13. [13]Y. Bidel, N. Zahzam, A. Bresson, C. Blanchard, M. Cadoret, A. V. Olesen, and R. Forsberg, “Absolute airborne gravimetry with a cold atom sensor”, J. Geod. 94, 20 (2020).
  14. [14]J. Vovrosh, A. Dragomir, B. Stray, and D. Boddice, “Advances in Portable Atom Interferometry-Based Gravity Sensing”, Sensors 23, 7651 (2023).DOI
  15. [15]M. Diament, G. Lion, G. P. Jomet-Métivier, S. Merlet, and S. Deroussi, “The AQG-B Absolute Quantum Gravimeter: A Promising Sensor for Volcano Monitoring”, IEEE Instrum. Meas. Mag. 27, 17 (2024).DOI
  16. [16]H. J. McGuinness, A. V. Rakholia, G. W. Biedermann, “High data-rate atom interferometer for measuring acceleration”, Appl. Phys. Lett. 100, 011106 (2012).
  17. [17]J. Lee, R. Ding, J. Christensen et al. (Collaboration), “A compact cold-atom interferometer with a high data-rate grating magneto-optical trap and a photonic-integrated-circuit-compatible laser system”, Nat. Commun. 13, 5131 (2022).
  18. [18]F. A. Narducci, A. T. Black, J. H. Burke, “Advances toward fieldable atom interferometers”, Adv. Phys.: X 7, 1946426 (2022).DOI
  19. [19]G. A. Olivares-Rentería, D. A. Lancheros-Naranjo, E. Gomez, J. A. Franco-Villafañe, “Quantum gravimetry in the same internal state using composite light Raman pulses”, Phys. Rev. A 101, 043613 (2020).
  20. [20]Q.-Q. Hu, H. Zhou, Y.-K. Luo, Q. Luo, W.-J. Kuang, F.-B. Wan, Y.-Y. Zhong, F.-F. Xu, “Improving the fringe contrast in an atomic gravimeter by optimizing the Raman laser intensity”, Optik 276, 170637 (2023).DOI
  21. [21]Y. Wang, J. Glick, T. Deshpande, K. DeRose, S. Saraf, N. Sachdeva, K. Jiang, Z. Chen, and T. Kovachy, “Robust Quantum Control via Multipath Interference for Thousandfold Phase Amplification in a Resonant Atom Interferometer”, Phys. Rev. Lett. 133, 243403 (2024).DOI
  22. [22]P. Cheiney, L. Fouché, S. Templier, F. Napoletano, B. Battelier, P. Bouyer, and B. Barrett, “Navigation-Compatible Hybrid Quantum Accelerometer Using a Kalman Filter”, Phys. Rev. Applied 10, 034030 (2018).
  23. [23]J. Wei, J. Huang, and C. Lee, “Adaptive robust high-precision atomic gravimetry”, Phys. Rev. Research 7, L012064 (2025).arxiv.org/abs/2409.08550
  24. [24]V. I. Yudin, O. N. Prudnikov, A. V. Taichenachev, M. Yu. Basalaeva, D. N. Kapusta, A. N. Goncharov, M. D. Radchenko, V. G. Pal’chikov, L. Zhou, and M. S. Zhan, “Lineshape-Asymmetry-Caused Shift in Atomic Interferometers”, JETP Lett. 122, 737 (2025).arxiv.org/abs/2512.18476
  25. [25]D. N. Kapusta, A. E. Bonert, A. N. Goncharov, V. I. Yudin, K. N. Adamov, A. V. Taichenachev, M. Yu. Basalaev, M. D. Radchenko, and O. N. Prudnikov, “T−3-Shift in a Short-Baseline Atomic Interferometer-Gravimeter”, JETP Lett. 123, 388 (2026).DOI
  26. [26]A. Louchet-Chauvet, T. Farah, Q. Bodart, A. Clairon, A. Landragin, S. Merlet, and F. P. Dos Santos, “The influence of transverse motion within an atomic gravimeter”, New J. Phys. 13, 065025 (2011).

Paper details

vlnc:W_6ke9arx8
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 8

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents