Abstract

Quantum telescopy, proposed by Grottesman et al., uses spatially entangled single-photon states to modify HBT stellar interferometry, potentially surpassing Michelson interferometry in resolution without baseline limits. However, finite source bandwidth, non-unit efficiency, detector response times, and celestial light bandwidth all affect its effectiveness. In this work, we consider a spatially entangled singe-photon state generated by beam-splitting a practical anti-bunched photon source from resonance fluorescence, which is a common method of generating single-photon states, and evaluate the signal level in quantum telescopy with inclusion of imperfection of detection system and finite bandwidth of celestial light. Here, given the incoming light, we optimize the parameters of the anti-bunched photon source and the detector system for the best signal-to-noise ratio (SNR), which can match that of the Michelson method in the ideal case but is always smaller in the realistic case. Alternatively, weak coherent states from heavily attenuated lasers can replace the entangled single-photon state but suffer low signal level, similar to HBT method. We find that the SNR with a realistic anti-bunched source for producing the reference fields can still beat the SNR of the coherent state scheme in the weak incoming field limit. The optimized parameters for the anti-bunched source and detection system will be a guide for future experimental endeavor.

Introduction

Due to diffraction of waves, the angular resolution of any imaging system is limited to λ/b\lambda/b for a radiation field at a wavelength of λ\lambda and an aperture size of bb. That is why all telescopes have large size, not only for collecting more light but also for higher resolution. The practical limitation of the size of the telescopes leads to the synthetic aperture technique which combines images from multiple telescopes separated by large distances through the interference technique, as first achieved in Michelson’s stellar interferometry [1, 2] and currently in operation as the Very Large Telescope Interferometer (VLTI) [3]. The radio frequency version (RF) is the very long baseline interferometry technique (VLBI) that combines electronic signals from radio telescopes at locations separated by a large distance [4]. For optical waves, however, since the most common method of detection is intensity measurement, which loses phase information after detection, observation of optical interference requires light to merge within the coherence length [1], so interference occurs before intensity detection. Because of the difficulty in balancing large optical paths within the coherence length, the baseline size in the optical regime is currently limited to a few hundred meters.

To circumvent this problem, Hanbury-Brown and Twiss (HBT) invented the stellar intensity interferometer [5] by measuring the intensity correlation between two spatially separated telescopes (Figure 1(a)) without the need to bring light together, similar to VLBI. However, due to the lack of phase information, the method is only applicable to symmetric objects such as stars to obtain their diameters. Moreover, the intensity correlation method relies on the coincidence of photons between telescopes, but celestial photons are uncorrelated so that the coincidence signal is orders of magnitude smaller than the direct intensity signal of Michelson’s stellar interferometric method.

Figure 1. (a) Traditional HBT intensity interferometer; (b) Phase sensitive HBT scheme with coherent reference fields. Red inset: Creation of coherence between reference fields by beam splitter and use of a spatially entangled single-photon state as the reference fields as proposed by Grottesman et al [6].

In 2012, Grottesman et al. (GJC) [6] proposed that spatially entangled nonlocal single-photon states in the form of (∣11,02⟩+eiΔϕ∣01,12⟩)/2(|1_1,0_2\rangle+ e^{i\Delta\phi}|0_1,1_2\rangle)/\sqrt{2} (Figure 1(b)) can be used as reference fields in a modified HBT interferometer for long-baseline astronomy applications of high-resolution optical imaging, with potential resolution far better than current state-of-the-art radio telescope arrays. The scheme was theoretically proven to have a signal level that matches that of the Michelson method in the weak input field limit [7]. The idea, known as quantum telescopy, was tested in a tabletop setting with heralded pulsed single photons [8, 9], and more recently with nonlocal entangled photon sources supported by quantum repeaters [10, 11], which predominantly emphasize entanglement distribution in quantum networks. However, these sources are not the ideal single-photon sources required for the quantum telescopy application because they have a finite bandwidth and usually operate in pulsed mode, which cannot temporally match celestial light in CW mode. Passive modification of celestial light or post-selection of photon events can match the temporal modes but at the expense of losses of celestial light. This approach was used by Deng et al. [12] to demonstrate for the first time the interference between celestial light (Sunlight) and single-photon sources on earth, which is the basis for quantum telescopy.

It is known that under heavy losses, a single-photon state is mixed with vacuum state and can be approximated by a weak coherent state, which then can be a temporary substitute before the technology of high fidelity transmission of entangled single-photon states is mature, as suggested by Grottesman et al. [6], and the feasibility has recently been demonstrated [13, 14, 15] as the phase dependent HBT effect. In addition to being readily available with high rate, another advantage of using coherent sources to replace entangled single-photon sources is that their phases can be easily stabilized to local optical clocks without the need for transmission. However, their use as references in quantum telescopy suffers from a low signal level issue, as proven in Ref. 7. This is similar to the original HBT intensity interferometer.

The spatially entangled single-photon state in the GJC scheme can be produced by beam splitting a single-photon state. Current state-of-the-art single-photon sources, with innovative techniques such as microcavity-enhanced Purcell effects, can achieve high emission rates at the GHz-level with an exceptional quality of g2∼0.02≠0g_2 \sim0.02 \ne0 [16, 17]. These single-photon sources operating in the CW mode, although non-ideal (g2≠0g_2 \ne0) and difficult to produce and transmit with high fidelity, can offer an enhancement in signal level, making them a better choice and worthy of further investigation.

From a practical experimental point of view, in addition to the non-zero g2g_2-value, the current state-of-the-art CW single-photon sources have a finite correlation time due to finite bandwidth. This means that even g2g_2 has a zero value, it is so only within a finite time period of its correlation time. The photon rate is also limited by the correlation time because the separation between photons cannot be smaller than the correlation time. Moreover, optical detectors have a finite response/resolving time that may limit the observable bandwidth of celestial light as well as the use of the single-photon state with finite bandwidth.

The aim of this work is to consider all these practical constraints in the application of single-photon states as reference fields to quantum telescopy. We will find the scope of the experimental parameters that can optimize the signal-to-noise ratio (SNR). We compare it with the Michelson direct intensity measurement scheme as well as the scheme of using coherent states as reference fields. We find that for weak incoming fields, the SNR of the scheme with single-photon states can match that of the Michelson scheme only under nearly ideal conditions but is always better than that of the scheme with coherent states. We investigate how to approach the ideal case through quantum state engineering.

The outline of the paper is as follows: we start in Sect. II by first describing the phase sensitive HBT effect with arbitrary sources as the references. Next in Sect. III, we consider practical constraints of anti-bunched light fields and the finite response time of the detection systems. In Sect. IV, we look into a practical anti-bunched photon source of resonance fluorescence. In Sect. V, we give a formula of the observed signal-to-noise ratio (SNR) as the criterion for comparison. We optimize the SNR in Sect. VI with various source and experimental parameters. In Sect. VII, we consider the effect of losses on SNR. In all of the discussion, we will use the scheme of Michelson stellar interferometry as a reference for comparison. For the HBT scheme, we will compare the results for using either coherent states or anti-bunched photon sources as the references and obtain an enhancement factor for the quantum sources.

Phase dependent HBT effect with anti-bunching light

The phase-dependent Hanbury Brown–Twiss (HBT) effect represents an extension of the traditional phase-insensitive HBT intensity interferometry (Figure 1(a)), achieved through the introduction of reference light fields that are mixed with input fields before detection (Figure 1(b)). To measure the phase coherence between the input fields, the reference fields must also be coherent, which can be done by splitting a common field with a beam splitter or using the spatially entangled single-photon state proposed by GJC, as shown in the red dashed box of Figure 1(b). In our previous work [15], an attenuated laser is split to serve as reference sources, enabling reconstruction of the full complex degree of coherence between two optical fields at separated locations. Similarly to the HBT scheme, coincidence measurements between the two detectors are performed to show an interference pattern from which the phase information is extracted. For arbitrary sources as references, it can be shown that the intensity correlation between detector D1 and D2 in Figure 1(b) is given by [15]

Γ2,2(τ)=I1I2g2(τ)+∣α1α2∣2g2ref(τ)+(I1∣α2∣2+I2∣α1∣2)[1+ξ∣γ(τ)∣cos⁡(φγ+Δφα)](1)\begin{aligned} \Gamma_{2,2}(\tau) ={}& I_1 I_2 g_2(\tau) + \lvert\alpha_1 \alpha_2 \rvert^2 g_2^{\mathrm{ref}}(\tau) \\ &+ (I_1\lvert\alpha_2 \rvert^2 + I_2\lvert\alpha_1 \rvert^2)[1+\xi\lvert\gamma(\tau)\rvert\cos(\varphi_\gamma+\Delta\varphi_\alpha)] \tag*{(1)} \end{aligned}

where ξ≡2∣α1α2∣I1I2/(I1∣α2∣2+I2∣α1∣2)\xi\equiv2\lvert\alpha_1\alpha_2\rvert\sqrt{I_1I_2}/(I_1\lvert\alpha_2\rvert^2+I_2\lvert\alpha_1\rvert^2) with I1,2I_{1,2}, ∣α1,2∣2\lvert\alpha_{1,2}\rvert^2 being the photon rates of the incoming fields E1,E2E_1,E_2 and the reference fields, respectively, γ(τ)=∣γ∣eiφγ\gamma(\tau)=\lvert\gamma\rvert e^{i\varphi_\gamma} is the second-order coherence function between E1,E2E_1,E_2 that will be measured, and g2(τ),g2ref(τ)g_2(\tau),g_2^{\mathrm{ref}}(\tau) are the normalized intensity cross-correlation functions between E1,E2E_1,E_2 and between two reference fields, respectively. In deriving Eq. (1), we assumed that the incoming fields E1,E2E_1,E_2 and the reference fields are totally uncorrelated and that the reference fields are path-balanced, so that they are completely coherent with ∣γ12ref∣=1\lvert\gamma_{12}^{\mathrm{ref}}\rvert=1 and a definite phase difference Δφα\Delta\varphi_\alpha. The last term is the interference term, corresponding to the signal, and can be made large by increasing the reference fields ∣α1,2∣2\lvert\alpha_{1,2}\rvert^2, while the first two terms are the background noise, which is mostly dominated by the second term, since the incoming celestial light is usually very weak. So, the background also increases with reference fields. The overall consequence can be seen through the visibility of the interference, which is a measure of the signal size and has the following form when we set I1=I2≡II_1=I_2\equiv I, ∣α1∣=∣α2∣≡∣α∣\lvert\alpha_1\rvert=\lvert\alpha_2\rvert\equiv\lvert\alpha\rvert:

V=2I∣α∣2∣γ12∣∣α∣4g2ref+2I(∣α∣2+I)(2)V=\frac{2I\lvert\alpha\rvert^2\lvert\gamma_{12}\rvert}{\lvert\alpha\rvert^4g_2^{\mathrm{ref}}+2I(\lvert\alpha\rvert^2+I)} \tag*{(2)}

where we set g2=2g_2=2 for the thermal fields that are usually from celestial light. For coherent states as reference fields [15], we have g2ref=1g_2^{\mathrm{ref}}=1, and VV is significant only when ∣α∣2∼I\lvert\alpha\rvert^2\sim I, as shown in the black curve in Figure 2 where we plot visibility VV as a function of ∣α∣2/I\lvert\alpha\rvert^2/I for various values of g2refg_2^{\mathrm{ref}}. But this leads to a coincidence measurement signal of Rc∝Γ2,2∼I2R_c\propto\Gamma_{2,2}\sim I^2, which gives the same signal level as the HBT method, and is, for weak celestial light, much smaller than the traditional Michelson stellar interferometry, which is proportional to II. On the other hand, if g2ref=0g_2^{\mathrm{ref}}=0, or the reference fields are ideally anti-correlated such as the ones split from a field in a single-photon state or anti-bunched source, we have V→1V\to1 for ∣α∣2/I≫1\lvert\alpha\rvert^2/I\gg1 from Eq. (2) and Figure 2 (red trace), so we can increase the signal rate without the reduction of visibility. This is the idea of Grottessman et al [6] of using a path-entangled single-photon state as the reference fields since such a single-photon state ideally has g2ref=0g_2^{\mathrm{ref}}=0.

Figure 2. Visibility of phase-dependent HBT effect as a function of ∣α∣2/I\lvert\alpha\rvert^2/I for reference sources with g2ref=0g_2^{\mathrm{ref}}=0 (red), 0.1 (blue), 0.5 (sky blue), 1.0 (black).

Furthermore, as shown in Figure 2, even for non-ideally anti-correlated reference fields with g2ref≠0g_2^{\mathrm{ref}}\ne0 (blue curves), VV drops slower than coherent state references (black curve, g2ref=1g_2^{\mathrm{ref}}=1). This means that we can increase ∣α∣2\lvert\alpha\rvert^2 to enhance signal level without compromising visibility.

Practical considerations

In practice, the anti-correlated reference fields can be produced by beam splitting a single-photon state or an anti-bunched optical field. However, we only have anti-bunched fields with g2ref(τ)=0g_2^{\mathrm{ref}}(\tau)=0 for τ≲Tcref\tau\lesssim T_c^{\mathrm{ref}}, the correlation time of the reference fields, and g2ref(τ)→1g_2^{\mathrm{ref}}(\tau)\to1 for τ≳Tcref\tau\gtrsim T_c^{\mathrm{ref}}. So, there would be a high probability of finding two photons beyond TcrefT_c^{\mathrm{ref}} and the separation between two photons is TcrefT_c^{\mathrm{ref}} on average, or the photon rate ∣α∣2\lvert\alpha\rvert^2 of the reference fields is limited by 1/Tcref1/T_c^{\mathrm{ref}}.

Furthermore, we experimentally measure the coincidence count within a certain coincidence window of TRT_R, which is related to the intensity correlation function in Eq. (1) through the coincidence rate as [18]

Rc=∫TRdτ  Γ2,2(τ).(3)R_c=\int_{T_R}d\tau\;\Gamma_{2,2}(\tau). \tag*{(3)}

So, the signal rate is proportional to TRT_R, which must be smaller than TcT_c, the coherence time of the incoming field in order to resolve γ(τ)\gamma(\tau) in time because an integration on γ(τ)\gamma(\tau) is performed in Eq. (3). TRT_R is further limited by TcrefT_c^{\mathrm{ref}}, the range in which g2ref(τ)∼0g_2^{\mathrm{ref}}(\tau)\sim0. All this thus sets a limit on how large we can have the reference field strength α\alpha to enhance the signal level of coincidence measurement. Ideally, if we could have a source that emits a photon deterministically in a fixed interval of TcrefT_c^{\mathrm{ref}}, then the antibunched photon source has a step function shape with g2ref(τ)=0g_{2}^{ref}(\tau)=0 for τ≤Tcref\tau\leq T_{c}^{ref} and ∣α∣2|\alpha|^{2} as large as 1/Tcref1/T_{c}^{ref}. We can then set TR=TcrefT_{R}=T_{c}^{ref} so that we have from Eqs. (1) and (3)

Rc≈2TRI∣α∣2[1+∣γ∣cos⁡(φγ+Δϕα)]=2I[1+∣γ∣cos⁡(φγ+Δϕα)],(4)\begin{aligned} R_{c} &\approx2T_{R}I|\alpha|^{2}[1+|\gamma|\cos(\varphi_{\gamma}+\Delta\phi_{\alpha})] \\ &=2I[1+|\gamma|\cos(\varphi_{\gamma}+\Delta\phi_{\alpha})], \tag*{(4)} \end{aligned}

where we dropped the I2I^{2} term assuming weak incoming fields. This is exactly the same signal rate as the traditional Michelson stellar interferometric method where two fields, each having a photon rate of II, interfere to measure the γ\gamma-function.

However, such an ideal source does not exist in the lab. Most of the common sources of anti-bunched photons [16, 17] are based on the resonance fluorescence process [19], where a coherent field on resonance with a single two-level emitter is incoherently scattered. They usually have g2ref(τ)≠0g_{2}^{ref}(\tau)\ne0 for τ≠0\tau\ne0. Let us examine what this type of photon source can offer us, and we will use the parameters of this photon source for optimization of the signal-to-noise ratio (SNR).

Realistic single-photon state from anti-bunched photon sources of resonance fluorescence

A common method to produce the spatially entangled single-photon state for the GJC quantum telecopic scheme is to split a single-photon state or an anti-bunched photon source by a 50:50 beam splitter, as shown in the red dashed box in Figure 1(b). In this section, we consider a realistic anti-bunched photon source from the atomic resonance fluorescence process where a single two-level atom is continuously driven by a coherent excitation source such as a cw laser and undergoes cyclic excitation and emission processes. At the moment right after the emission of one photon, the single atom falls back to the ground state and the probability of emitting a subsequent photon is non-zero only at some delayed time after the prior emission event when the atom is repumped to the excited state.

The theory of resonance fluorescence (RFl) was worked out by Kimble and Mandel in 1976 [20], where the normalized intensity correlation function g2RFl(τ)g_{2}^{RFl}(\tau) of the scattered fluorescence was calculated, showing the signature anti-bunching effect [19, 21]. In general, the g2g_{2}-function depends on the Rabi frequency Ω≡E0d/ℏ\Omega\equiv E_{0}d/\hbar (dd is the atomic transition dipole moment and E0E_{0} is the peak amplitude of the electric field of the coherent driving field), the decay constant β\beta of the upper atomic energy level or half the Einstein A-coefficient, and the detuning Δ≡ωL−ωa\Delta\equiv\omega_{L}-\omega_{a} of the driving frequency ω0\omega_{0} from the atomic transition frequency ωa\omega_{a}. The exact form is quite complicated and is presented in Eq. (18) in Appendix A for zero detuning. To see the behavior of g2RFl(τ)g_{2}^{RFl}(\tau) in Eq. (18), we

plot it in Figure 3 for four values of Ω/β(0.5,1,2,10)\Omega/\beta(0.5,1,2,10) as a function of the dimensionless delay time τˉ≡βτ\bar{\tau}\equiv\beta\tau. The time correlation function g2RFl(τˉ)g_{2}^{RFl}(\bar{\tau}) begins with a value of zero at τˉ=0\bar{\tau}=0 immediately after a photon is emitted, but rises for non-zero τˉ\bar{\tau} and asymptotically approaches unity for large τˉ\bar{\tau} through a series of damped oscillations. The number of these oscillations depends primarily on the pump strength Ω/β\Omega/\beta. A higher Ω/β\Omega/\beta results in a steeper rising slope, which shortens the interval between successive photon emissions. As can be seen, g2RFl(τ)g_{2}^{RFl}(\tau) does not have the ideal step function shape required to obtain Eq. (4) in the last section.

Figure 3. Normalized intensity correlation function g2RFlg_{2}^{RFl} of resonance fluorescence verses τˉ≡βτ\bar{\tau}\equiv\beta\tau for Ω/β=10,2,1,0.5\Omega/\beta=10,2,1,0.5.

The photon rate of the scattered light is quite simple and is given by

∣α∣2=β12Ω2/β212Ω2/β2+1⟶βfor Ω≫β.(5)|\alpha|^{2}=\beta\frac{\frac{1}{2}\Omega^{2}/\beta^{2}}{\frac{1}{2}\Omega^{2}/\beta^{2}+1}\longrightarrow\beta\qquad\text{for }\Omega\gg\beta. \tag*{(5)}

Therefore, when pumped hard (Ω≫β\Omega\gg\beta), the photon rate and the correlation time TcRFlT_{c}^{RFl} are determined by β\beta and the Rabi frequency Ω\Omega, respectively.

So, given the level II of the incoming light and its bandwidth Δω=1/Tc\Delta\omega=1/T_{c}, we need to optimize the detector parameter of TRT_{R} and the source parameters of β,Ω\beta,\Omega of the anti-bunched reference fields to maximize the measurement output.

Signal-to-Noise Ratio (SNR)

Although the visibility of interference provides a sense of the signal size against the background, the metric that truly matters in a measurement is the signal-to-noise ratio. We can derive it from the coincidence count rate RcR_{c} through Eqs. (1), (3). In the experiment, we measure the total coincidence count Nc=RcTN_{c}=R_{c}T for a data accumulation period TT. The “Signal” part is the size of the interference fringe, and from Eq. (1) with I1=I2=II_{1}=I_{2}=I, α1=α2=α\alpha_{1}=\alpha_{2}=\alpha for maximum visibility, we find it as the coefficient in front of the cosine function:

Signal=RcsignalT=2TI∣α∣2∫TRdτ∣γ(τ)∣.(6)\mathrm{Signal}=R_c^{\mathrm{signal}}T=2TI|\alpha|^2\int_{T_R}d\tau|\gamma(\tau)|. \tag*{(6)}

The “Noise” part is the fluctuation of the total coincidence count NcN_c. Since the data accumulation time TT is quite long for weak incoming light, it is usually much longer than the correlation time of all fields. So, the coincidence events are all uncorrelated and can be treated as a Poissonian process for which the fluctuation is ΔNc=Nc\Delta N_c=\sqrt{N_c}. But NcN_c changes in the data set due to interference (the cosine term). Since we usually take the data of a full fringe to measure the “Signal” part, we use an average over one full fringe for evaluating “Noise”, which just removes the cosine term and keeps the baseline terms:

Noise=Ncave=T∫TRdτ{I2g2(τ)+∣α∣4g2ref(τ)+2I∣α∣2}.(7)\begin{aligned} \mathrm{Noise}&=\sqrt{N_c^{\mathrm{ave}}}\\ &=\sqrt{T\int_{T_R}d\tau\left\{I^2g_2(\tau)+|\alpha|^4g_2^{\mathrm{ref}}(\tau)+2I|\alpha|^2\right\}}. \tag*{(7)} \end{aligned}

Notice that we do not include dark counts in our analysis. They will contribute as accidental coincidences and raise the baseline to add extra noise.

Combining Eq. (6),(7), we find the SNR as follows:

SNR=2IT∫TRdτ∣γ(τ)∣∫TRdτ{I2∣α∣4g2(τ)+g2ref(τ)+2I∣α∣2}=SNRMI2NR γˉ(TR)I2∣α∣4gˉ2(TR)+gˉ2Rref+2I∣α∣2.(8)\begin{aligned} SNR&=\frac{2I\sqrt{T}\int_{T_R}d\tau|\gamma(\tau)|}{\sqrt{\int_{T_R}d\tau\left\{\frac{I^2}{|\alpha|^4}g_2(\tau)+g_2^{\mathrm{ref}}(\tau)+\frac{2I}{|\alpha|^2}\right\}}}\\ &=SNR_{MI}\frac{\sqrt{2N_R}\,\bar{\gamma}(T_R)}{\sqrt{\frac{I^2}{|\alpha|^4}\bar{g}_2(T_R)+\bar{g}_{2R}^{\mathrm{ref}}+\frac{2I}{|\alpha|^2}}}. \tag*{(8)} \end{aligned}

where SNRMI≡2ITSNR_{MI}\equiv\sqrt{2IT} is the SNR for Michelson stellar interferometry, NR≡ITRN_R\equiv IT_R is the photon number of the incoming field within the coincidence window TRT_R. γˉ(TR)≡1TR∫TRdτ∣γ(τ)∣\bar{\gamma}(T_R)\equiv\frac{1}{T_R}\int_{T_R}d\tau|\gamma(\tau)|, gˉ2(TR)≡1TR∫TRdτg2(τ)\bar{g}_2(T_R)\equiv\frac{1}{T_R}\int_{T_R}d\tau g_2(\tau), and gˉ2Rref≡1TR∫TRdτg2ref(τ)\bar{g}_{2R}^{\mathrm{ref}}\equiv\frac{1}{T_R}\int_{T_R}d\tau g_2^{\mathrm{ref}}(\tau) are the averages of the corresponding quantities within the coincidence window TRT_R and are close to 11, g2(0)g_2(0), and g2ref(0)g_2^{\mathrm{ref}}(0), respectively, for TR≪TcT_R\ll T_c, the coherence time of the incoming field (This condition is for time-resolved coincidence measurement of the complex function γ(τ)\gamma(\tau)).

For coherent states as reference fields with g2ref=1g_2^{\mathrm{ref}}=1, we find that the SNR is maximum when the coherent reference fields are much stronger than the incoming fields: ∣α∣2≫I|\alpha|^2\gg I with

SNRcoh=SNRMI2NR.(9)SNR_{\mathrm{coh}}=SNR_{MI}\sqrt{2N_R}. \tag*{(9)}

So, for weak celestial light with NR≪1N_R\ll1, the phase-sensitive HBT intensity stellar interferometry has a much smaller SNR than the Michelson stellar interferometry.

Notice that from Eq. (8), we find that by using anti-bunched photon sources even with 0≠g2ref<10\ne g_2^{\mathrm{ref}}<1, we can still enhance the SNR by a factor of 1/g2ref1/\sqrt{g_2^{\mathrm{ref}}} when I/∣α∣2≪g2ref<1I/|\alpha|^2\ll g_2^{\mathrm{ref}}<1:

SNRanti=SNRcoh/g2ref.(10)SNR_{\mathrm{anti}}=SNR_{\mathrm{coh}}/\sqrt{g_2^{\mathrm{ref}}}. \tag*{(10)}

Next, we will consider anti-bunched photon sources from resonance fluorescence (with g2(0)=0g_2(0)=0) as the reference fields and find how it compares with both the coherent state scheme and the Michelson scheme.

Optimization of SNR for resonance fluorescence as reference sources

Now let us examine the anti-bunched photon source of resonance fluorescence as the reference field, which has the adjustable parameters of β,Ω/β\beta,\Omega/\beta. For perfect alignment in the resonance fluorescence collection system, we have the mean photon rate of the source given in Eq. (5). Substituting it into Eq. (8), we have the SNR for resonance fluorescence (RFl):

SNRRFlSNRMI=NRNR2βR2(Ω2+2β2Ω2)2+12g2RRFl(βR,Ωβ)+NRβRΩ2+2β2Ω2.(11)\begin{aligned} \frac{SNR_{RFl}}{SNR_{MI}} &=\frac{\sqrt{N_R}}{\sqrt{\frac{N_R^2}{\beta_R^2}\left(\frac{\Omega^2+2\beta^2}{\Omega^2}\right)^2+\frac{1}{2}g_{2R}^{RFl}(\beta_R,\frac{\Omega}{\beta})+\frac{N_R}{\beta_R}\frac{\Omega^2+2\beta^2}{\Omega^2}}}. \tag*{(11)} \end{aligned}

where we set gˉ2(TR)≈2\bar{g}_2(T_R)\approx2, γˉ(TR)≈1\bar{\gamma}(T_R)\approx1 by assuming that the incoming field is thermal light and TR≪TcT_R\ll T_c. βR≡βTR\beta_R\equiv\beta T_R and gˉ2RRFl(βR,Ω/β)≡1βR∫βTRdτg2RFl(τ,Ω/β)\bar{g}_{2R}^{RFl}(\beta_R,\Omega/\beta)\equiv\frac{1}{\beta_R}\int_{\beta T_R}d\tau g_2^{RFl}(\tau,\Omega/\beta) with τ≡βt\tau\equiv\beta t, and g2RFl(τ,Ω/β)g_2^{RFl}(\tau,\Omega/\beta) given in Eq. (18) for resonance fluorescence.

With fixed incoming light level II and bandwidth Δω=1/Tc\Delta\omega=1/T_c, we choose the detector response with fixed TR=(0.02∼0.2)TcT_R=(0.02\sim0.2)T_c for time-resolved coincidence measurement. So, NR=ITRN_R=IT_R is fixed. We need to optimize βR,Ω/β\beta_R,\Omega/\beta for the best SNRRFlSNR_{RFl}.

Due to the complicated form of g2RFlg_2^{RFl}, the optimization process has to be performed numerically and is quite tedious. We present it in Appendix B. However, for NR≪1N_R\ll1, we can obtain a simple analytical result summarized as

(Ωβ)(op)=2independent of NR,\left(\frac{\Omega}{\beta}\right)^{(\mathrm{op})}=2\quad\text{independent of }N_R,
βR(op)=(3NR/2)13,\beta_R^{(\mathrm{op})}=(3N_R/2)^{\frac{1}{3}},
SNRRFl(op)SNRMI=(2/3)56NR16.(12)\frac{SNR_{RFl}^{(\mathrm{op})}}{SNR_{MI}}=(2/3)^{\frac{5}{6}}N_R^{\frac{1}{6}}. \tag*{(12)}

For NR∼1N_R\sim1, we resort to numerical evaluation and optimization. The process is quite complicated and is presented in the Supplementary Materials [22]. We only display the results here. The numerically optimized SNR ratio SNRRFl(op)/SNRMISNR_{RFl}^{(\mathrm{op})}/SNR_{MI} and βR(op)\beta_R^{(\mathrm{op})} (circles) are plotted versus the photon number NRN_R of the incoming field in

Figure 4(a,Figure 4b) on a log-log scale. As can be seen, the dependence expressed in Eq. (12) is followed quite well for small NRN_R (the red solid line in (a) and the red dashed line in (b) are from Eq. (12)). However, after NRN_R reaches 0.16, βR(op)\beta_R^{(\mathrm{op})} begins to increase drastically and SNRRFl(op)→SNRcoh(op)\mathrm{SNR}_{RFl}^{(\mathrm{op})} \to\mathrm{SNR}_{coh}^{(\mathrm{op})} (The blue line in (a) is from Eq. (9)).

Figure 4. (a) The optimized SNR ratio and (b) βR(op)\beta_R^{(\mathrm{op})} versus the photon number NRN_R of the incoming field. Circles are from numerical simulation. The red line in (a) is from Eq. (12) for the scheme with resonance fluorescence and the blue line in (a) is from Eq. (9) for the coherent state scheme. The dashed red line in (b) is from Eq. (12) for βR(op)\beta_R^{(\mathrm{op})}.

For small NRN_R, using an anti-bunched photon source as reference fields can indeed improve SNR as compared to the scheme with the coherent state as reference. This can be seen by comparing the result in Eq. (12) with the result in Eq. (9) for the scheme of coherent state as reference fields and obtain an enhancement ratio as

SNRRFl(op)/SNRcoh≈0.5NR−1/3.(13)\mathrm{SNR}_{RFl}^{(\mathrm{op})}/\mathrm{SNR}_{coh} \approx0.5N_R^{-1/3}. \tag*{(13)}

The numerically calculated enhancement ratio (circles) is plotted against NRN_R in Figure 5, which shows a higher enhancement for weaker input (NR≪1N_R \ll1) but no enhancement when NR→1N_R \to1. The solid line is from Eq. (13), which fits well with the circles for small NR≪1N_R \ll1.

Figure 5. Enhancement ratio as a function of input photon number NRN_R in log scale. The solid line is from Eq. (13).

From Figure 4(a), we find that for a weak incoming field (NR≪1N_R \ll1), the SNR with resonance fluorescence as reference fields is smaller than that of the Michelson scheme, and the SNR ratio decreases with the drop of NRN_R. This

is due to the non-ideal shape of g2RFlg_2^{RFl} as shown in Figure 3, where g2RFlg_2^{RFl} arises from zero rather quickly.

In deriving Eq. (4), we used an unrealistic step function shaped g2ref(τ)g_2^{ref}(\tau) function with a completely flat bottom at zero. A realistic source of resonance fluorescence gives a g2RFlg_2^{RFl} arising from zero in the τ2\tau^2-dependence (see Appendix B). Let us now consider a flatter bottom of g2refg_2^{ref} than g2RFlg_2^{RFl} with a slowly increasing value to approximate the completely flat bottom. A high power dependence of g2ref∝τMg_2^{ref} \propto\tau^M (M>2M > 2) for τ\tau near zero has a slower increasing rate than the τ2\tau^2-dependence of g2RFlg_2^{RFl} near τ=0\tau= 0. We work out this in Appendix B for the general case in Eq. (8) with NR≪1N_R \ll1 and obtain the following results:

SNRM(op)=SNRMI(MM+1)M2(M+1)(CNR2)12(M+1)\mathrm{SNR}_{M}^{(\mathrm{op})}=\mathrm{SNR}_{MI}\left(\frac{M}{M+1}\right)^{\frac{M}{2(M+1)}}\left(\frac{CN_R}{2}\right)^{\frac{1}{2(M+1)}}
∝SNRMI×NR12(M+1).(14)\propto\mathrm{SNR}_{MI}\times N_R^{\frac{1}{2(M+1)}}. \tag*{(14)}

with the optimized value achieved when the photon number of the reference field NRref≡∣α∣2TR=[2NR(M+1)/CM]1M+1N_R^{ref}\equiv|\alpha|^2T_R=[2N_R(M+1)/CM]^{\frac{1}{M+1}}, where we assume g2ref(τ)≈C(∣α∣2τ)Mg_2^{ref}(\tau)\approx C(|\alpha|^2\tau)^M (M>2M>2) for ∣α∣2τ≪1|\alpha|^2\tau\ll1 with CC as some dimensionless quantity of size around 1. Figure 6 plots the optimized SNR ratio SNRM(op)/SNRMI\mathrm{SNR}_{M}^{(\mathrm{op})}/\mathrm{SNR}_{MI} as a function of NRN_R for various values of MM (CC is set as 27/4, the value for resonance fluorescence). So, as the bottom of g2refg_2^{ref} becomes flatter (M→M\to large), the SNR approaches SNRMI\mathrm{SNR}_{MI}.

Figure 6. Optimized SNR ratio SNRM(op)/SNRMISNR_{M}^{(op)}/SNR_{MI} given in Eq. (16) as a function of NRN_R for various values of MM

The bottom-flattened g2refg_2^{ref} can be engineered by the spectral structure of the anti-bunched photon source.

EFFECT OF LOSS IN REFERENCE

Until now, our analysis has focused on the ideal scenario with no loss in reference fields. However, in any realistic implementation of a single-photon state, loss is inevitable due to such effects as inefficient single-photon collection, absorption and scattering in propagation, and mode mismatch in interference.

The effect of loss LL on the reference field from resonance fluorescence is simply to add a factor of 1−L1-L in front of Eq. (5):

∣αL∣2=(1−L)β212Ω2/β212Ω2/β2+1.(15)|\alpha_L|^2=(1-L)\beta^2\frac{\frac{1}{2}\Omega^2/\beta^2}{\frac{1}{2}\Omega^2/\beta^2+1}. \tag*{(15)}

The optimization process is still the same, but the results for NR≪1N_R \ll1 become

(Ω/β)(op−L)=2 independent of NR,(\Omega/\beta)^{(op-L)}=2\ \text{independent of }N_R,
βR(op−L)=(3NR/21−L)1/3,\beta_R^{(op-L)}=\left(\frac{3N_R/2}{1-L}\right)^{1/3},
SNRRFl(op−L)SNRMI=(1−L)1/3(23)5/6NR1/6.(16)\frac{SNR_{RFl}^{(op-L)}}{SNR_{MI}}=(1-L)^{1/3}\left(\frac{2}{3}\right)^{5/6}N_R^{1/6}. \tag*{(16)}

So, the SNR drops by a factor of (1−L)1/3(1-L)^{1/3}.

For the case of a flatter bottom of g2refg_2^{ref} with g2ref∝τMg_2^{ref}\propto\tau^M for τ→0\tau\to0, we need to replace ∣α∣2|\alpha|^2 in Eq. (8) with (1−L)∣α∣2(1-L)|\alpha|^2. For NR≪1N_R\ll1, it is straightforward to find (through Eq. (31) in Appendix B)

SNRM(op−L)SNRMI=(1−L)M2(M+1)SNRM(op)SNRMI.(17)\frac{SNR_M^{(op-L)}}{SNR_{MI}}=(1-L)^{\frac{M}{2(M+1)}}\frac{SNR_M^{(op)}}{SNR_{MI}}. \tag*{(17)}

So, the drop factor =(1−L)M/2(M+1)→(1−L)1/2=(1-L)^{M/2(M+1)}\to(1-L)^{1/2} (M→∞M\to\infty) is slightly more for larger MM (flatter bottom).

However, for NR∼1N_R\sim1, we find from Eq. (8) after the replacement of ∣α∣2|\alpha|^2 by (1−L)∣α∣2(1-L)|\alpha|^2, it is equivalent to the change of NRN_R to NR/(1−L)N_R/(1-L) with a significant increase for the large loss of 1−L≪11-L\ll1. According to Figure 5, this may lead to the drop in the enhancement effect over the coherent state scheme and eventually to no enhancement. So, a large loss of single-photon states makes it equivalent to a weak coherent state.

It should be mentioned that the spatially entangled single-photon state used here is usually produced by beam splitting a single-photon state and its photon rate is therefore reduced by half or L=0.5L=0.5 [7, 23]. So, SNRRFlSNR_{RFl} is reduced by (1−L)1/3=1/23(1-L)^{1/3}=1/\sqrt[3]{2} according to Eq. (16).

Conclusion and discussion

Although numerous challenges remain in implementing very-long-baseline telescopes with single-photon states as references, we identify in this work another issue related to the temporal correlation of the single-photon state. Through theoretical and numerical analysis, we demonstrate that an ideal single-photon reference exhibiting a step-like correlation function is preferred. This will minimize the background coincidence counts from the reference while maintaining a high intensity for the reference fields in order to increase the signal level. Under ideal conditions, the signal level achievable with a perfect single-photon state becomes comparable to that of the direct interference method of Michelson stellar interferometry.

However, practical single-photon sources, such as those from resonance fluorescence, have a shape of temporal correlation far from ideal, leading to a signal-to-noise ratio (SNR) lower than that of the Michelson method, especially at low incoming photon number. From our analysis, we find that spectral engineering to change the shape of the temporal correlation can improve the SNR, eventually matching that of the Michelson method. On the other hand, using anti-bunched photon sources is still better than using coherent states as the reference field, providing quantum enhancement to SNR, with the enhancement factor increasing for a lower input photon number.

In our investigation, the quantity NR≡ITRN_R\equiv I T_R appears constantly. This is the photon number of the incoming field within the detector’s resolution time TRT_R. To see its meaning, we can compare it to a quantity commonly known as the occupation number δ\delta per mode. For CW fields, the coherence time TcT_c of the fields is known to define a single temporal mode. So, δ=ITc\delta=I T_c is the average photon number per mode, or the so-called occupation number per mode. Since we require TR<TcT_R<T_c for time-resolved coincidence measurement, NR<δN_R<\delta is then the average photon number per mode measured by the detector. δ=1/(ehν/kT−1)\delta=1/(\mathrm{e}^{h\nu/kT}-1) for a blackbody of temperature TT. The Sun has δ≈0.01\delta\approx0.01 at 555 nm but in the microwave background radiation such as the cosmic microwave background, δ≈108\delta\approx10^8. We can estimate NRN_R for some celestial sources. For example, for the brightest star Sirius, from the spectral data Fλ=1.35×10−8 erg cm−2 s−1 A˚−1F_\lambda=1.35\times10^{-8}\,\mathrm{erg\,cm^{-2}\,s^{-1}\,\mathring{A}^{-1}} at 555 nm [24], we obtain a photon flux of I=9.5×107I=9.5\times10^7/s per polarization mode for an area of 1 m21\,\mathrm{m}^2 area and a spectral width of 0.5 nm (coherence time Tc=20T_c=20 ps). Taking TR=Tc/5=4T_R=T_c/5=4 ps for the time resolved measurement, we arrive at NR=ITR∼4×10−4≪1N_R=I T_R\sim4\times10^{-4}\ll1. This photon level justifies the use of the single-photon state as reference fields for the enhancement of the signal level.

The condition NR≪1N_R\ll1 in our analysis means that the average photon number per detected mode is much smaller than 1, corresponding to weak incoming fields. Our analysis shows that when NR∼1N_R \sim1, there is no advantage in using an entangled single-photon state as the reference fields compared to the coherent state. This is consistent with the single-mode analysis performed by Tsang [7] and is also in line with the SNR analysis of the homodyne/heterodyne detection technique [25, 26], where the shot noise is the limiting factor for weak incoming fields [27]. The large occupation number in the microwave explains well why coherent states are good enough as LO for radio telescope arrays.

Since phase-dependent Hanbury Brown–Twiss (HBT) interferometry is based on interference between all fields, spatial mode matching is essential for achieving high visibility. Our current analysis focuses primarily on temporal mode match through time resolved coincidence measurement (single-mode). The spatial mode mismatch will reduce the visibility of interference, and thus the signal size. It is equivalent to the loss effect in detection. We did not consider inefficient detectors in our analysis. Since coincidence between two detectors is measured, the signal size will drop by a factor of η2\eta^2 with η\eta as the quantum efficiency of the detectors. This is a disadvantage compared to the drop factor of η\eta for the direct intensity measurement by one detector in the Michelson method.

Acknowledgments

The authors thank Professor M. Raymer for challenging them to consider the issue of signal-to-noise ratio in various schemes in this paper. The work was supported by Joint NSFC/RGC Collaborative Research Scheme (CRS-CityU103/24), the General Research Fund from Hong Kong Research Grants Council (Grant No. 11301624).

g2-function from resonance fluorescence

The theory of resonance fluorescence was worked out by Kimble and Mandel in 1976 [20]. The results can be written as follows. For simplicity, we set the detuning to zero, then the normalized intensity correlation function g2RFl(τ)g_{2}^{\mathrm{RFl}}(\tau) is given by

g2RFl(τ)=1−(A+13B2+9A2)(19−43A+4A2)(12Ω2/β2+1)(Ω2/β2)(12A−13)e(−4/3+2A)βτ−4(12Ω2/β2+1)Ω2/β2e−(4/3+A)βτ(FH+GJH2+J2cos⁡Bβτ−GH−FJH2+J2sin⁡Bβτ)(18)g_{2}^{\mathrm{RFl}}(\tau)=1-\left(\frac{A+\frac{1}{3}}{B^{2}+9A^{2}}\right)\frac{\left(\frac{1}{9}-\frac{4}{3}A+4A^{2}\right)\left(\frac{1}{2}\Omega^{2}/\beta^{2}+1\right)}{\left(\Omega^{2}/\beta^{2}\right)\left(\frac{1}{2}A-\frac{1}{3}\right)}e^{(-4/3+2A)\beta\tau} -\frac{4\left(\frac{1}{2}\Omega^{2}/\beta^{2}+1\right)}{\Omega^{2}/\beta^{2}}e^{-(4/3+A)\beta\tau}\left(\frac{FH+GJ}{H^{2}+J^{2}}\cos B\beta\tau-\frac{GH-FJ}{H^{2}+J^{2}}\sin B\beta\tau\right) \tag*{(18)}

where A=12(η++η−)A=\frac{1}{2}(\eta_{+}+\eta_{-}), B=123(η+−η−)B=\frac{1}{2}\sqrt{3}(\eta_{+}-\eta_{-}) with

η±=13{9Ω2/β2−1±[(9Ω2/β2−1)2+(3Ω2/β2−1)3]1/2}1/3,(19)\eta_{\pm}=\frac{1}{3}\left\{9\Omega^{2}/\beta^{2}-1\pm\left[\left(9\Omega^{2}/\beta^{2}-1\right)^{2}+\left(3\Omega^{2}/\beta^{2}-1\right)^{3}\right]^{1/2}\right\}^{1/3}, \tag*{(19)}

and

F=227+13A−A3+3AB2,(20)F=\frac{2}{27}+\frac{1}{3}A-A^{3}+3AB^{2}, \tag*{(20)}
G=−13B−B3+3A2B,(21)G=-\frac{1}{3}B-B^{3}+3A^{2}B, \tag*{(21)}
H=8AB2+83B2,(22)H=8AB^{2}+\frac{8}{3}B^{2}, \tag*{(22)}
J=8AB+6A2B−2B3,(23)J=8AB+6A^{2}B-2B^{3}, \tag*{(23)}

which is a function of Ω/β\Omega/\beta and βτ\beta\tau with Ω\Omega as the Rabi frequency and β\beta as the half Einstein A-coefficient. Figure 3 shows g2RFlg_{2}^{\mathrm{RFl}} as a function τˉ≡βτ\bar{\tau}\equiv\beta\tau for various values of Ω/β\Omega/\beta.

Optimization of the SNR

For fixed NRN_{R}, we just need to minimize the expression inside the square root in the denominator of Eq. (11):

D≡(NRβR12Ω2/β2+112Ω2/β2)2+12g2RRFl(βR,Ω/β)+NRβR12Ω2/β2+112Ω2/β2.(24)D\equiv\left(\frac{N_{R}}{\beta_{R}}\frac{\frac{1}{2}\Omega^{2}/\beta^{2}+1}{\frac{1}{2}\Omega^{2}/\beta^{2}}\right)^{2}+\frac{1}{2}g_{2R}^{\mathrm{RFl}}(\beta_{R},\Omega/\beta)+\frac{N_{R}}{\beta_{R}}\frac{\frac{1}{2}\Omega^{2}/\beta^{2}+1}{\frac{1}{2}\Omega^{2}/\beta^{2}}. \tag*{(24)}

Notice that for celestial light, NRN_{R} is usually quite small. For example, the brightest star of Sirius has a spectral flux density of 1.35×10−11 W/cm2/μm1.35\times10^{-11}\,\mathrm{W/cm^{2}/\mu m} [24]. For a 1 meter size telescope of 1 GHz bandwidth (Tc=1nsT_{c}=1\mathrm{ns}), this translates to I=3×105I=3\times10^{5} photon/s or NR=3×10−5≪1N_{R}=3\times10^{-5}\ll1 for TR∼0.1nsT_{R}\sim0.1\mathrm{ns} of a typical SNSPD in current photon detector technology. Therefore, we can neglect the first term in Eq. (24). Furthermore, we need the second term of g2RFlg_{2}^{\mathrm{RFl}} to be as small as possible, which means that the integral range of g2RFlg_{2}^{\mathrm{RFl}} should be small so that g2RFlg_{2}^{\mathrm{RFl}} is close to zero. In other words, τˉ=βτ\bar{\tau}=\beta\tau should be much smaller than 1.

For τˉ=βτ≪1\bar{\tau}=\beta\tau\ll1, we can find the asymptotic expansion for g2RFl(τˉ)g_{2}^{\mathrm{RFl}}(\bar{\tau}) in Eq. (18). With the coefficients of the two exponential functions and the cosine and sine functions denoted as T1T_{1}, T2T_{2}, CC, SS, respectively, the asymptotic expansion has the following form

g2RFl(τ)=1−T1e(−4/3+2A)βτ−T2e−(4/3+A)βτ[Ccos⁡(Bβτ)−Ssin⁡(Bβτ)]=a0+a1βτ+a2β2τ2+O((βτ)3),(25)g_{2}^{\mathrm{RFl}}(\tau)=1-T_{1}e^{(-4/3+2A)\beta\tau}-T_{2}e^{-(4/3+A)\beta\tau}\left[C\cos(B\beta\tau)-S\sin(B\beta\tau)\right] =a_{0}+a_{1}\beta\tau+a_{2}\beta^{2}\tau^{2}+O((\beta\tau)^{3}), \tag*{(25)}

where

a0=1−T1−T2C,(26)a_{0}=1-T_{1}-T_{2}C, \tag*{(26)}
a1=−T1(−43+2A)+T2C(43+A)+T2SB,(27)a_{1}=-T_{1}\left(-\frac{4}{3}+2A\right)+T_{2}C\left(\frac{4}{3}+A\right)+T_{2}SB, \tag*{(27)}
a2=−T12(−43+2A)2−T2C2(43+A)2−T2SB(43+A)+T2C2B2.(28)a_{2}=-\frac{T_{1}}{2}\left(-\frac{4}{3}+2A\right)^{2}-\frac{T_{2}C}{2}\left(\frac{4}{3}+A\right)^{2}-T_{2}SB\left(\frac{4}{3}+A\right)+\frac{T_{2}C}{2}B^{2}. \tag*{(28)}

After some lengthy derivation, it is straightforward to show: a0=0=a1a_{0}=0=a_{1}, a2=1+Ω22β2a_{2}=1+\frac{\Omega^{2}}{2\beta^{2}}. With these, the expression in Eq. (24) becomes

D=βR26(1+Ω22β2)+NRβR(1+2β2Ω2),(29)D=\frac{\beta_R^2}{6}\left(1+\frac{\Omega^2}{2\beta^2}\right)+\frac{N_R}{\beta_R}\left(1+\frac{2\beta^2}{\Omega^2}\right), \tag*{(29)}

which has a minimum value of

Dmin⁡=(32)5/3NR2/3(30)D_{\min}=\left(\frac{3}{2}\right)^{5/3}N_R^{2/3} \tag*{(30)}

when Ωβ=2\frac{\Omega}{\beta}=2 and βR=3NR3/2\beta_R=\sqrt[3]{3N_R}/2. This leads to a simple analytical optimization result in Eq. (12) after substituting the expression inside the square root in Eq. (11) with the minimum value above.

As discussed in deriving Eq. (4), a flat bottom of g2RFlg_{2}^{RFl} with a slowly increasing value is preferred. To see this quantitatively, we rewrite Eq. (8) as

SNR=SNRMI2NRg2Rref+2NRNRref,(31)SNR=SNR_{MI}\frac{\sqrt{2N_R}}{\sqrt{g_{2R}^{ref}+\frac{2N_R}{N_R^{ref}}}}, \tag*{(31)}

where we dropped the first term in the denominator and set ∣γ∣≈1|\gamma|\approx1 due to I/∣α∣2≪1I/|\alpha|^2\ll1 and TR≪TCT_R\ll T_C, and NR≡∣α∣2TRN_R\equiv|\alpha|^2T_R is the average photon number in TRT_R for the reference fields (Ideally, NRref=1N_R^{ref}=1 but usually NRref≲1N_R^{ref}\lesssim1). To have an estimate of gˉ2Rref\bar{g}_{2R}^{ref}, we rewrite it as

gˉ2Rref=1TR∫TRdτg2ref(τ)=1NRref∫NRrefdτˉg2ref(τˉ)(32)\begin{aligned} \bar{g}_{2R}^{ref}=\frac{1}{T_R}\int_{T_R}d\tau g_{2}^{ref}(\tau) \\ &=\frac{1}{N_R^{ref}}\int_{N_R^{ref}}d\bar{\tau}g_{2}^{ref}(\bar{\tau}) \tag*{(32)} \end{aligned}

by changing the integral variable to dimensionless τˉ≡∣α∣2τ\bar{\tau}\equiv|\alpha|^2\tau. For an anti-bunched photon field with g2ref(0)=0g_{2}^{ref}(0)=0 and a flat bottom of g2ref(τˉ)g_{2}^{ref}(\bar{\tau}) with a slowly rising value, we assume that g2ref(τˉ)g_{2}^{ref}(\bar{\tau}) has an asymptotic form of g2ref(τˉ)∼CτˉMg_{2}^{ref}(\bar{\tau})\sim C\bar{\tau}^{M} for τˉ≪1\bar{\tau}\ll1 (C∼1C\sim1 and MM are constant. M=2M=2 for resonance fluorescence, see Appendix B). Then, Eq. (31) becomes

SNRSNRMI=NRC/2M+1(NRref)M+NRNRref≤(MM+1)M2(M+1)(CNR/2)12(M+1),(33)\frac{SNR}{SNR_{MI}}=\frac{\sqrt{N_R}}{\sqrt{\frac{C/2}{M+1}(N_R^{ref})^M+\frac{N_R}{N_R^{ref}}}} \leq\left(\frac{M}{M+1}\right)^{\frac{M}{2(M+1)}}(CN_R/2)^{\frac{1}{2(M+1)}}, \tag*{(33)}

with the maximum achieved when NRref=[2NR(M+1)/CM]1M+1N_R^{ref}=[2N_R(M+1)/CM]^{\frac{1}{M+1}}. So, as the bottom of g2refg_{2}^{ref} becomes flatter (M→M\to large), the SNR approaches SNRMISNR_{MI}.

When NR∼1N_R\sim1, we cannot use the asymptotic form for g2RFlg_{2}^{RFl}. The numerical evaluation is performed, but the procedure is rather complicated, so we place it in the Supplementary Materials [22] and only present the results in the main text as Figure 4, Figure 5.

References

  1. [1]A. A. Michelson, On the application of interference methods to astronomical measurements, Astrophys. J. 51, 257 (1920).
  2. [2]A. A. Michelson and F. G. Pease, Measurement of the diameter of alpha-orionis by the interferometer, Astrophys. J. 53, 249 (1921).
  3. [3]H. A. McAlister, T. A. ten Brummelaar, D. R. Gies, W. Huang, W. G. Bagnuolo, Jr., M. A. Shure, J. Sturmann, L. Sturmann, N. H. Turner, S. F. Taylor, D. H. Berger, E. K. Baines, E. Grundstrom, C. Ogden, S. T. Ridgway, and G. van Belle, First results from the CHARA array. I. an interferometric and spectroscopic study of the fast rotator α Leonis (Regulus), Astrophys. J. 628, 439 (2005).
  4. [4]M. Ryle and A. Hewish, The synthesis of large radio telescopes, Monthly Notices of the Royal Astronomical Society 120, 220 (1960).
  5. [5]R. Hanbury Brown and R. Q. Twiss, A test of a new type of stellar interferometer on Sirius, Nature 178, 1046 (1956).DOI
  6. [6]D. Gottesman, T. Jennewein, and S. Croke, Longer-Baseline telescopes using quantum repeaters, Phys. Rev. Lett. 109, 070503 (2012).pubmed.ncbi.nlm.nih.gov/23006349
  7. [7]M. Tsang, Quantum nonlocality in weak-thermal-light interferometry, Phys. Rev. Lett. 107, 270402 (2011).DOI
  8. [8]M. R. Brown, M. Allgaier, V. Thiel, J. D. Monnier, M. G. Raymer, and B. J. Smith, Interferometric imaging using shared quantum entanglement, Phys. Rev. Lett. 131, 210801 (2023).DOI
  9. [9]G. Thekkadath, D. England, F. Bouchard, Y. Zhang, M. Kim, and B. Sussman, Intensity interferometry for holography with quantum and classical light, Sci. Adv. 9, eadh1439 (2023).DOI
  10. [10]P.-J. Stas, Y.-C. Wei, M. Sirotin, Y. Q. Huan, U. Yazlar, F. A. Arias, E. Knyazev, G. Baranes, B. Machielse, S. Grandi, D. Riedel, J. Borregaard, H. Park, M. Lončar, A. Suleymanzade, and M. D. Lukin, Entanglement-assisted non-local optical interferometry in a quantum network, Nature 651, 326 (2026).DOI
  11. [11]B. Wang, X.-Y. Luo, B.-F. Gao, J.-L. Liu, C.-Y. Wang, Z. Yan, Q.-M. Ke, D. Teng, M.-Y. Zheng, Y. Cao, J. Li, C.-Z. Peng, Q. Zhang, X.-H. Bao, and J.-W. Pan, Memory-Assisted nonlocal interferometer towards long-Baseline telescopes, arXiv:2511.10988 (2025).arxiv.org/abs/2511.10988
  12. [12]Y.-H. Deng, H. Wang, X. Ding, Z.-C. Duan, J. Qin, M.-C. Chen, Y. He, Y.-M. He, J.-P. Li, Y.-H. Li, L.-C. Peng, E. S. Matekole, T. Byrnes, C. Schneider, M. Kamp, D.-W. Wang, J. P. Dowling, S. Höfling, C.-Y. Lu, M. O. Scully, and J.-W. Pan, Quantum interference between light sources separated by 150 million kilometers, Phys. Rev. Lett. 123, 080401 (2019).DOI
  13. [13]Z. Y. Ou and X. Li, Unbalanced fourth-order interference beyond coherence time, Phys. Rev. Research 4, 023125 (2022).DOI
  14. [14]J. Crawford, D. Dolzhenko, M. Keach, A. Muen-inghoff, R. A. Abrahao, J. Martinez-Rincon, P. Stankus, S. Vinstekich, and A. Nomerotski, Towards quantum telescopes: demonstration of a two-photon interferometer for precision astrometry, Opt. Express 31, 44246 (2023).DOI
  15. [15]X. Tang, Y. Zhang, X. Guo, L. Cui, X. Li, and Z. Y. Ou, Phase-dependent Hanbury-Brown and Twiss effect for the complete measurement of the complex coherence function, Light: Sci. and Appl. 14, 46 (2025).
  16. [16]N. Tomm, A. Javadi, N. O. Antoniadis, D. Najer, M. C. Löbl, A. R. Korsch, R. Schott, S. R. Valentin, A. D. Wieck, A. Ludwig, et al., A bright and fast source of coherent single photons, Nat. Nanotechnol. 16, 399 (2021).
  17. [17]X. Ding, Y.-P. Guo, M.-C. Xu, R.-Z. Liu, G.-Y. Zou, J.-Y. Zhao, Z.-X. Ge, Q.-H. Zhang, H.-L. Liu, L.-J. Wang, et al., High-efficiency single-photon source above the loss tolerant threshold for efficient linear optical quantum computing, Nat. Photonics 19, 387 (2025).arxiv.org/abs/2311.08347
  18. [18]L. Mandel and E. Wolf, Optical Coherence and Quantum Optics (Cambridge University Press, 1995).
  19. [19]H. J. Kimble, M. Dagenais, and L. Mandel, Photon anti-bunching in resonance fluorescence, Phys. Rev. Lett. 39, 691 (1977).
  20. [20]H. J. Kimble and L. Mandel, Theory of Resonance fluorescence, Phys. Rev. A 13, 2123 (1976).DOI
  21. [21]M. Dagenais and L. Mandel, Investigation of two-time correlations in photon emissions from a single atom, Phys. Rev. A 18, 2217 (1978).DOI
  22. [22]See supplemental material [url] for detailed procedure of numerical evaluation and optimization.
  23. [23]Y. Zhang and T. Jennewein, Criteria for optimal entanglement-assisted long baseline telescopy, Phys. Rev. Research 7, 043278 (2025).
  24. [24]R. C. Bohlin, HUBBLE SPACE TELESCOPE CALSPEC FLUX STANDARDS: SIRIUS (AND VEGA), Astronomical Journal 147, 127 (2014).DOI
  25. [25]M. A. Johnson, A. L. Betz, and C. H. Townes, 10-μm heterodyne stellar interferometer, Phys. Rev. Lett. 33, 1617 (1974).DOI
  26. [26]D. D. S. Hale, M. Bester, W. C. Danchi, W. Fitelson, S. Hoss, E. A. Lipman, J. D. Monnier, P. G. Tuthill, and C. H. Townes, The Berkeley infrared spatial interferometer: a heterodyne stellar interferometer for the mid-infrared, Astrophys. J. 537, 998 (2000).DOI
  27. [27]X. Tang and Z. Y. Ou, Optical interference by amplitude measurement: Spectral analysis, Phys. Rev. Res. 8, 013122 (2026).DOI

Paper details

vlnc:W_6pmayvea
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents