Abstract

In standard homodyne detection, an unknown optical signal state is combined with a local oscillator (LO) at a beam splitter (BS), and the appropriately integrated intensities at the two outputs of the BS are subtracted to obtain an approximate quadrature measurement. Accurate quadrature measurements require a high-amplitude LO and high-efficiency detectors. By varying the LO phase, the optical state in the mode matching the LO can be reconstructed. In many practical settings, a high-intensity LO is not desirable, which has led to the exploration of homodyne-like measurement schemes that replace photodiodes with photon-counting detectors and use an LO with a low average photon number. In this paper, we investigate what features of the unknown state can be determined by counting the total-photon number in one or both outgoing paths after the BS, keeping the mode of the LO fixed but adjusting its phase and magnitude. We find that it is possible to determine the unknown optical state in the mode matching the LO conditional on the number of photons in the orthogonal modes on the same path. If both the phase and the intensity of the LO can be varied, the statistics of just one of the detectors is sufficient to infer these parameters, but both detectors are required when the LO has a fixed intensity. Our analysis is carried out in the infinite-data limit, assuming access to the full photon-number distribution from one or both detectors.

introduction

Standard homodyne detection is a key technique for characterizing quantum states of light [1]. In this scheme, the unknown state is combined with a high-intensity coherent state, known as the local oscillator (LO) or phase reference, on a balanced beam splitter (BS) at various relative phase settings spanning the full angular range. The output beams are detected by photodiodes, producing electrical signals that are integrated over time and subtracted. In the limit of infinite LO intensity, the result corresponds to a quadrature measurement of the unknown state in the mode matching the LO at the given phase. Here, “mode” typically refers to a normalized spatially localized solution of Maxwell’s equations in free space or a dielectric medium such as an optical fiber. Measuring quadratures across all phases allows for reconstruction of the reduced density matrix of the state in the mode matching the LO [2, 3].

Standard homodyne detection has some limitations - the most obvious being the need for a high-intensity reference, which can potentially disturb sensitive quantum information in systems such as Rydberg clouds [4, 5, 6, 7], in quantum non-demolition experiments probing atomic ensembles [8, 9, 10], and in non-destructive cavity QED experiments [11, 12]. Another obvious limitation is the blindness of the scheme to the modes orthogonal to the LO. These two features of standard homodyne detection are closely related. Even if photodiodes were ideal intensity detectors, in the weak LO regime the final processed signal would no longer correspond to a quadrature measurement, but would contain information about the modes orthogonal to the LO.

Photon-number-resolving (PNR) detectors, also referred to as photon counters, serve a role similar to photodiodes but are designed for situations where, on average, only a few photons are present in the absorbed pulse. [13, 14] Current state-of-the-art PNR detectors, such as transition-edge-sensors (TESs), can distinguish up to sixteen photons in a single pulse [15]. Further, a combination of TESs in a multiplexed scheme, acting as an effective PNR detector, can resolve up to 100 photons [16]. These advances motivate the exploration of homodyne-like measurement schemes in which photodiodes are replaced by PNR detectors, and the LO is attenuated to contain only a few photons on average.

These schemes, often referred to as “hybrid” or “weak-field homodyne” detectors [13], have been studied both theoretically and experimentally. Early theoretical work showed that a single PNR detector and an unbalanced BS suffice to determine an unknown single-mode state [17]. Experimentally, such schemes have been used to measure two-photon phase coherence [18], test Bell inequalities [19], create superpositions of vacuum and single-photon states with well-defined phases [20], perform state discrimination [21, 22, 23], and estimate entanglement in bipartite systems [24]. Further demonstrations include state reconstruction for single-mode [25, 26, 27, 28, 29] and two-mode squeezed states [30]. Other studies have experimentally characterized weak-field homodyne detectors under the assumption that there are no photons in detectable modes other than the mode matching the LO [31, 32]. Interestingly, it was shown that, in principle, an arbitrary multimode state can be determined using one single-photon detector, provided the LO can be prepared in any desired mode [33]. Recently, there has also been interest in exploring detection schemes where the LO is not a coherent state, but rather a non-classical state such as a cat state [34].

A common assumption across these studies of weak-field homodyne is that either there is only one, known mode containing photons and this mode matches that of the LO, or the set of modes of interest is known and the LO can be matched to or scanned over them. The former does not account for photons in other modes, while the latter has substantial measurement overhead. For a fixed LO mode, a desirable goal of weak-field homodyne is to not only determine the marginal state of the mode, but also its correlation with photons in other modes, without the need to change or scan the LO mode. Correlations with photons in other modes can yield valuable insights, whereas neglecting them, especially when their content is non-negligible, can lead to significant errors in estimation. Strengthening the power of weak-field homodyne to achieve these goals is one of the key motivations for the present work.

We theoretically investigate what can be learned about an unknown state with an unspecified mode structure by combining it with a LO in a weak coherent state on a BS (not necessarily balanced) and performing photon counting on one or both output ports. We assume that the LO is pulsed, where the LO mode is defined by the pulse shape. The PNR detectors count photons during a time window containing the LO pulse, and they are equally sensitive to all modes that may have photons in this time window. For this work, we assume that the probabilities of all photon number outcomes are learned. This is the infinite data limit for ideal PNR detectors. Perfect PNR detectors are not required in the infinite data limit. For example, inefficiency or loss and added noise can be modeled as classical noise processes following perfect photon counting, and it is often possible to invert the classical noise process given the count probabilities [35].

Our analysis of the infinite data limit establishes what is fundamentally inferrable about the unknown state for the experimental configurations considered. We find that, for a fixed LO mode, the measurement statistics yield significantly more information about the unknown state than is possible with standard homodyne detection. In particular, it is possible to determine the unknown state in the mode matching the LO conditional on each number of photons present in the orthogonal modes, and one may also determine the photon number probabilities in those modes. We find that the measurement statistics from a single PNR detector, collected over a sufficient range of LO magnitudes and phases, are sufficient to extract this information. When two PNR detectors are used, a fixed-magnitude LO is sufficient to extract this information provided the measurement statistics are known for all phase values.

Overview

We begin by summarizing the main theoretical results established in this work. Our analysis considers an unknown multimode input state ρ\rho combined with a weak LO in a fixed mode on an arbitrary lossless BS, followed by detection with one or two noiseless and lossless PNR detectors that do not distinguish between the modes in their respective BS ports (Fig. 1) in the infinite data limit. Throughout the text, such idealized PNR detectors are referred to simply as counters. § 0.3 provides a detailed description of the measurement configuration, relevant physical quantities, and the main mathematical instruments used in deriving the results. Following this setup, we make a key observation in § 0.4 that the measurement statistics exhibit a nontrivial symmetry. Specifically, Prop. 4.1 and Prop. 4.2 together establish that the statistics are invariant under precisely those passive linear transformations (PLTs) on the input state that act trivially on the LO-matched mode (mode 1). Averaging over the symmetry group yields the so-called twirled-state, given in Thm. 4.3, with Cor. 4.4 showing that there exists a two-mode representative ρt\rho_t that is indistinguishable from ρ\rho. We refer to ρt\rho_t as the two-mode twirled state corresponding to ρ\rho.

§ 1 then addresses the central question of whether the measurement statistics determine ρt\rho_t. The analysis is based on representing the measurement statistics by the moments of the total photon-number operators (n^a′(\hat{n}'_a and n^b′)\hat{n}'_b) measured by the two counters. This in turn imposes a requirement on ρt\rho_t: its Husimi function must be determined by its moments. We next show with Prop. 5.2 that, in order to uniquely determine ρt\rho_t, the normally ordered moments ⟨(a^1†)ka^1ℓ(a^2†)na^2n⟩\langle(\hat{a}_1^\dagger)^k\hat{a}_1^\ell(\hat{a}_2^\dagger)^n\hat{a}_2^n\rangle for k≥ℓk \ge\ell and arbitrary nn are both sufficient and necessary. Here, a^1\hat{a}_1 and a^2\hat{a}_2 denote the annihilation operators for modes 1 and 2, respectively. For input states with bounded photon number, Cor. 5.3 establishes that only finitely many of these moments are required. These results rely on the operator-ordering relation of Lem. 5.1, which establishes a one-to-one correspondence between the Husimi moments of ρt\rho_t and the moments ⟨(a^1†)ka^1ℓ(a^2†)na^2n⟩\langle(\hat{a}_1^\dagger)^k\hat{a}_1^\ell(\hat{a}_2^\dagger)^n\hat{a}_2^n\rangle.

Within this framework, we obtain detailed results for both the single- and two-counter configurations by asking whether the measurement statistics, known for a given set of probe LO states, determine the moments ⟨(a^1†)ka^1ℓ(a^2†)na^2n⟩\langle(\hat{a}_1^\dagger)^k\hat{a}_1^\ell(\hat{a}_2^\dagger)^n\hat{a}_2^n\rangle. For a single counter, Thm. 5.9 shows that access to statistics across a neighborhood of probe amplitudes suffices to recover all required moments, thereby determining ρt\rho_t. When the maximum photon number of the input state is bounded by NN, Thm. 5.7 and Cor. 5.8 relaxes this requirement, showing that (N+1)2(N+1)^2 probe amplitudes are sufficient. If there is no bound on the maximum number of photons, Prop. 5.10 establishes that no finite set of probe amplitudes suffices. Moreover, for fixed-magnitude probes with variable phase, Prop. 5.11 shows that the single-counter scheme is limited to reconstructing states with at most one photon.

The two-counter configuration is strictly more efficient in terms of the number of measurement settings required to obtain the same information. While Prop. 5.13 shows that finitely many probes are still insufficient to determine ρt\rho_t without a photon-number bound, Thm. 5.14 demonstrates that collecting measurement statistics by scanning the probe phase at fixed magnitude recovers ρt\rho_t in full. The final result, Prop. 5.15, establishes a connection between the two-counter measurement scheme and standard homodyne detection. It shows that the reduced state of the system is fully characterized by the expectations of the normally ordered operators :(n^b′−ξn^a′)n::(\hat{n}'_b-\xi\hat{n}'_a)^n: for all nn. Here, ξ\xi is a parameter determined by the BS, taking the value ξ=1\xi=1 for a balanced BS. Homodyne detection is recovered in the limit of a strong LO, where ⟨:(n^b′−n^a′)n:⟩≈⟨(n^b′−n^a′)n⟩\langle:(\hat{n}'_b-\hat{n}'_a)^n:\rangle\approx\langle(\hat{n}'_b-\hat{n}'_a)^n\rangle. In the appendix we provide basic results involving normal and antinormal ordering and PLTs, and we show the Husimi functions of Gaussian states, Fock states and their superpositions and mixtures are determined by their moments.

Preliminaries

Description of the Measurement Configuration

The schematic of the measurement configuration is shown in Figure 1. The unknown input state ρ\rho and the LO probe state σ\sigma are directed toward the two input ports of the BS. The input ρ\rho lives in SS mutually orthogonal modes, characterized by SS annihilation operators a^1,…,a^S\hat{a}_1,\ldots,\hat{a}_S. We do not assume that SS is known, but require that it be finite for our analysis. The BS induces interference between modes in its two input ports that share identical spatio-temporal and polarization characteristics. Thus, there exist SS modes in the LO input port, characterized by annihilation operators b^1,…,b^S\hat{b}_1,\ldots,\hat{b}_S, where each b^i\hat{b}_i is matched with a^i\hat{a}_i.

Diagram of the measurement configuration with both PNR detectors present

Figure 1. Diagram of the measurement configuration with both PNR detectors present. The unknown input state ρ\rho and probe state σ\sigma are directed towards the inputs of the BS, and the outputs are measured by two PNR detectors, denoted by counter 1 and counter 2. The detectors measure the total-photon-number operators n^a′\hat{n}'_a and n^b′\hat{n}'_b in their respective output paths of the BS. If the measurement configuration uses only one detector, then only counter 1 is present.

We denote the physical Hilbert space of the input state by Ha\mathcal{H}_a, and of the probe state by Hb\mathcal{H}_b. We further denote the Hilbert spaces of the output modes of the BS associated with the operators a^i′\hat{a}'_i and b^i′\hat{b}'_i by Ha′\mathcal{H}_{a'} and Hb′\mathcal{H}_{b'}, respectively. We denote the vector of annihilation operators (a^1,…,a^S)(\hat{a}_1,\ldots,\hat{a}_S) by a^\hat{\mathbf{a}}, and the vector of creation operators (a^1†,…,a^S†)(\hat{a}_1^\dagger,\ldots,\hat{a}_S^\dagger) by a^†\hat{\mathbf{a}}^\dagger, and similarly for the operators in the other ports of the BS. We generally interpret vectors written inline as column vectors. We refer to creation and annihilation operators as mode operators. Given any two vectors of mode operators, say a^=(a^1,…,a^S)\hat{\mathbf{a}}=(\hat{a}_1,\ldots,\hat{a}_S) and b^=(b^1,…,b^S)\hat{\mathbf{b}}=(\hat{b}_1,\ldots,\hat{b}_S), the direct sum a^⊕b^\hat{\mathbf{a}}\oplus\hat{\mathbf{b}} is defined as the concatenated vector (a^1,…,a^S,b^1,…,b^S)(\hat{a}_1,\ldots,\hat{a}_S,\hat{b}_1,\ldots,\hat{b}_S).

For any vector of KK annihilation operators c^=(c^1,…,c^K)\hat{\mathbf{c}}=(\hat{c}_1,\ldots,\hat{c}_K) with associated Hilbert space Hc\mathcal{H}_c, we refer to the KK-dimensional vector space spanned by its components c^i\hat{c}_i as the mode space of Hc\mathcal{H}_c. We denote the Fock state with nin_i photons in mode c^i\hat{c}_i by ∣n1,…,nK⟩=⨂i=1K∣ni⟩|n_1,\ldots,n_K\rangle=\bigotimes_{i=1}^{K}|n_i\rangle. Similarly, a coherent state with complex amplitude αi\alpha_i in mode c^i\hat{c}_i is written as ∣α⟩=⨂i=1K∣αi⟩|\boldsymbol{\alpha}\rangle=\bigotimes_{i=1}^{K}|\alpha_i\rangle. We use Greek letters in bra-ket notation to indicate coherent states and Latin letters for Fock states. Throughout this work, the probe state is the coherent state σ=∣γ⟩⟨γ∣⊗∣0⃗⟩⟨0⃗∣\sigma=|\gamma\rangle\langle\gamma|\otimes|\vec{0}\rangle\langle\vec{0}|, where ∣0⃗⟩|\vec{0}\rangle denotes the vacuum state for modes b^2,…,b^S\hat{b}_2,\ldots,\hat{b}_S.

References

  1. [1]H. A. Bachor and T. C. Ralph, A Guide to Experiments in Quantum Optics, 3rd ed. (Wiley-VCH, 2019).
  2. [2]U. Leonhardt, M. Munroe, T. Kiss, T. Richter, and M. Raymer, Sampling of photon statistics and density matrix using homodyne detection, Optics Communications 127, 144 (1996).DOI
  3. [3]G. M. D’Ariano, M. G. A. Paris, and M. F. Sacchi, Quantum tomography (2003), arXiv:quant-ph/0302028 [quant-ph].
  4. [4]D. Maxwell, D. J. Szwer, D. Paredes-Barato, H. Busche, J. D. Pritchard, A. Gauguet, K. J. Weatherill, M. P. A. Jones, and C. S. Adams, Storage and control of optical photons using Rydberg polaritons, Phys. Rev. Lett. 110, 103001 (2013).
  5. [5]K. M. Beck, M. Hosseini, Y. Duan, and V. Vuletić, Large conditional single-photon cross-phase modulation, Proceedings of the National Academy of Sciences 113, 9740 (2016).
  6. [6]T. Peyronel, O. Firstenberg, Q.-Y. Liang, S. Hofferberth, A. Gorshkov, T. Pohl, M. Lukin, and V. Vuletic, Quantum nonlinear optics with single photons enabled by strongly interacting atoms, Nature 488, 57 (2012).
  7. [7]J. D. Thompson, T. L. Nicholson, Q.-Y. Liang, S. H. Cantu, A. V. Venkatramani, S. Choi, A. E. Fedorov, D. Viscor, T. Pohl, M. D. Lukin, and V. Vuletic, Symmetry-protected collisions between strongly interacting photons, Nature 542, 206 (2017).
  8. [8]A. Kuzmich, L. Mandel, and N. P. Bigelow, Atomic quantum non-demolition measurements and squeezing, Phys. Rev. Lett. 85, 1594 (2000).
  9. [9]T. Takano, M. Fuyama, R. Namiki, and Y. Takahashi, Spin squeezing of a cold atomic ensemble with the nuclear spin of one-half, Phys. Rev. Lett. 102, 033601 (2009), arXiv:0808.2353 [quant-ph].
  10. [10]M. Koschorreck, M. Napolitano, B. Dubost, and M. W. Mitchell, Quantum nondemolition measurement of large-spin ensembles by dynamical decoupling, Phys. Rev. Lett. 105, 093602 (2010), arXiv:1005.2807 [quant-ph].
  11. [11]B. M. Peden, D. Meiser, M. L. Chiofalo, and M. J. Holland, Nondestructive cavity QED probe of bloch oscillations in a gas of ultracold atoms, Physical Review A 80, 043803 (2009).
  12. [12]R. D. Niederriter, C. Schlupf, and P. Hamilton, Cavity probe for real-time detection of atom dynamics in an optical lattice, arXiv preprint (2020), arXiv:2006.04776 [quant-ph].
  13. [13]A. Migdall, S. V. Polyakov, J. Fan, and J. C. Bienfang, Single-Photon Generation and Detection, Experimental Methods in the Physical Sciences, Vol. 45 (Academic Press, 2013).
  14. [14]S. Slussarenko and G. J. Pryde, Photonic quantum information processing: A concise review, Applied Physics Reviews 6, 041303 (2019).
  15. [15]T. Gerrits, A. Lita, B. Calkins, and S. W. Nam, Superconducting transition edge sensors for quantum optics, in Superconducting Devices in Quantum Optics (Springer International Publishing, Cham, 2016) pp. 31–60.
  16. [16]M. Eaton, A. Hossameldin, R. J. Birrittella, P. M. Alsing, C. C. Gerry, H. Dong, C. Cuevas, and O. Pfister, Resolution of 100 photons and quantum generation of unbiased random numbers, Nature Photonics 17, 106 (2023).
  17. [17]S. Wallentowitz and W. Vogel, Unbalanced homodyning for quantum state measurements, Phys. Rev. A 53, 4528 (1996).
  18. [18]M. Koashi, K. Kono, M. Matsuoka, and T. Hirano, Probing the two-photon phase coherence of parametrically down-converted photons by a local oscillator, Phys. Rev. A 50, R3605 (1994).
  19. [19]A. Kuzmich, I. A. Walmsley, and L. Mandel, Violation of Bell’s inequality by a generalized Einstein-Podolsky-Rosen state using homodyne detection, Phys. Rev. Lett. 85, 1349 (2000).
  20. [20]K. J. Resch, J. S. Lundeen, and A. M. Steinberg, Quantum state preparation and conditional coherence, Phys. Rev. Lett. 88, 113601 (2002).
  21. [21]M. Bina, A. Allevi, M. Bondani, and S. Olivares, Homodyne-like detection for coherent state discrimination in the presence of phase noise, Opt. Express 25, 10685 (2017).
  22. [22]M. Bina, A. Allevi, M. Bondani, and S. Olivares, Phase-reference monitoring in coherent-state discrimination assisted by a photon-number resolving detector, Scientific Reports 6, 26025 (2016).
  23. [23]C. R. Müller, M. A. Usuga, C. Wittmann, M. Takeoka, C. Marquardt, U. L. Andersen, and G. Leuchs, Quadrature phase shift keying coherent state discrimination via a hybrid receiver, New Journal of Physics 14, 083009 (2012).
  24. [24]G. Puentes, A. Datta, A. Feito, J. Eisert, M. B. Plenio, and I. A. Walmsley, Entanglement quantification from incomplete measurements: applications using photon-number-resolving weak homodyne detectors, New Journal of Physics 12, 033042 (2010).
  25. [25]S. Olivares, A. Allevi, G. Caiazzo, M. G. A. Paris, and M. Bondani, Quantum tomography of light states by photon-number-resolving detectors, New Journal of Physics 21, 103045 (2019).
  26. [26]A. Allevi, M. Bina, S. Olivares, and M. Bondani, Homodyne-like detection scheme based on photon-number-resolving detectors, International Journal of Quantum Information 1740016 (2017).DOI
  27. [27]G. Puentes, J. S. Lundeen, M. P. A. Branderhorst, H. B. Coldenstrodt-Ronge, B. J. Smith, and I. A. Walmsley, Bridging particle and wave sensitivity in a configurable detector of positive operator-valued measures, Phys. Rev. Lett. 102, 080404 (2009).
  28. [28]L. Zhang, H. B. Coldenstrodt-Ronge, A. Datta, G. Puentes, J. Lundeen, X.-M. Jin, B. Smith, M. Plenio, and I. Walmsley, Mapping coherence in measurement via full quantum tomography of a hybrid optical detector, Nature Photonics 6, 364 (2012).
  29. [29]G. S. Thekkadath, D. S. Phillips, J. F. F. Bulmer, W. R. Clements, A. Eckstein, B. A. Bell, J. Lugani, T. A. W. Wolterink, A. Lita, S. W. Nam, T. Gerrits, C. G. Wade, and I. A. Walmsley, Tuning between photon-number and quadrature measurements with weak-field homodyne detection, Phys. Rev. A 101, 031801 (2020).DOI
  30. [30]G. Donati, T. J. Bartley, X. min Jin, M. D. Vidrighin, A. Datta, M. Barbieri, and I. A. Walmsley, Observing optical coherence across Fock layers with weak-field homodyne detectors, Nature communications 5, 5584 (2014).DOI
  31. [31]L. Zhang, A. Datta, H. B. Coldenstrodt-Ronge, X.-M. Jin, J. Eisert, M. B. Plenio, and I. A. Walmsley, Recursive quantum detector tomography, New Journal of Physics 14, 115005 (2012).
  32. [32]H. Xu, F. Xu, T. Theurer, D. Egloff, Z.-W. Liu, N. Yu, M. B. Plenio, and L. Zhang, Experimental quantification of coherence of a tunable quantum detector, Phys. Rev. Lett. 125, 060404 (2020).DOI
  33. [33]J. Tiedau, V. S. Shchesnovich, D. Mogilevtsev, V. Ansari, G. Harder, T. J. Bartley, N. Korolkova, and C. Silberhorn, Quantum state and mode profile tomography by the overlap, New Journal of Physics 20, 033003 (2018).DOI
  34. [34]J. Combes and A. P. Lund, Homodyne measurement with a schrödinger cat state as a local oscillator, Phys. Rev. A 106, 063706 (2022).DOI
  35. [35]J. S. Ivan, K. K. Sabapathy, and R. Simon, Operator-sum representation for bosonic gaussian channels, Physical Review A 84, 042311 (2011).DOI
  36. [36]H. S. Wilf, Generatingfunctionology, 3rd ed. (A K Peters/CRC Press, 2005).
  37. [37]U. Leonhardt, Measuring the Quantum State of Light (Cambridge University Press, Cambridge, UK, 1997).
  38. [38]K. Schmüdgen, The Moment Problem, Graduate Texts in Mathematics (Springer International Publishing, 2017).DOI
  39. [39]W. Fulton and J. Harris, Representation Theory: A First Course, Graduate Texts in Mathematics No. 129 (Springer, New York, 1991).DOI
  40. [40]R. A. Lorentz, Multivariate Birkhoff Interpolation, Lecture Notes in Mathematics (Springer Berlin, Heidelberg, 1992).DOI
  41. [41]A. E. Lita, D. V. Reddy, V. B. Verma, R. P. Mirin, and S. W. Nam, Development of superconducting single-photon and photon-number resolving detectors for quantum applications, Journal of Lightwave Technology 40, 7578 (2022).DOI
  42. [42]G. Sauer, M. Kolarczik, R. Gomez, J. Conrad, and F. Steinlechner, Resolving photon numbers using ultra-high-resolution timing of a single low-jitter superconducting nanowire detector (2023), arXiv:2310.12472 [quant-ph].arxiv.org/abs/2310.12472
  43. [43]R. Cheng, Y. Zhou, S. Wang, M. Shen, T. Taher, and H. X. Tang, A 100-pixel photon-number-resolving detector unveiling photon statistics, Nature Photonics 17, 112 (2023).DOI
  44. [44]J. S. Lundeen, A. Feito, H. Coldenstrodt-Ronge, K. L. Pregnell, C. Silberhorn, T. C. Ralph, J. Eisert, M. B. Plenio, and I. A. Walmsley, Tomography of quantum detectors, Nature Physics 5, 27 (2009).DOI
  45. [45]P. C. Humphreys, B. J. Metcalf, T. Gerrits, T. Hiemstra, A. E. Lita, J. Nunn, S. W. Nam, A. Datta, W. S. Kolthammer, and I. A. Walmsley, Tomography of photon-number resolving continuous-output detectors, New Journal of Physics 17, 103044 (2015).DOI
  46. [46]J. Fiurášek, Fundamental limits on determination of photon number statistics from measurements with multiplexed on/off detectors, Phys. Rev. Research 7, 033147 (2025), arXiv:2503.17480 [quant-ph].DOI
  47. [47]G. Brida, L. Ciavarella, I. P. Degiovanni, M. Genovese, L. Lolli, M. G. Mingolla, F. Piacentini, M. Rajteri, E. Taralli, and M. G. A. Paris, Quantum characterization of superconducting photon counters, New Journal of Physics 14, 085001 (2012).
  48. [48]L. A. Morais, T. Weinhold, M. P. de Almeida, J. Combes, M. Rambach, A. Lita, T. Gerrits, S. W. Nam, A. G. White, and G. Gillett, Precisely determining photon-number in real time, Quantum 8, 1355 (2024).DOI
  49. [49]A. Avagyan, Quantum state characterization using measurement configurations inspired by homodyne detection, arXiv:2305.19397 [quant-ph] (2023).
  50. [50]D. S. Phillips, Advanced measurements for quantum photonics and quantum technologies, Ph.D. thesis, University of Oxford (2020).DOI
  51. [51]W. Rudin, Real and Complex Analysis, Higher Mathematics Series (McGraw-Hill Education, 1987).

Paper details

vlnc:W_6qsv5d8z
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 3

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

AI

View statement
Looking for related papers…
Contents