WorksPhysics and Astronomy
Theory of magneto-electrokinetics in unidirectional electrolyte flow: Hydrodynamic potential and Hall effect
Abstract
We develop a theoretical framework for magneto-electrokinetic transport in dilute electrolytes under unidirectional flow and streaming current conditions. Unlike standard magnetohydrodynamics in liquid metals, where charge carriers are electrons and conductivity is typically uniform, electrolytes exhibit spatially varying ion densities and additional forces such as osmotic pressure. In steady state, the coupled Navier–Stokes, Nernst–Planck, and Poisson equations become analytically tractable. We derive a Boltzmann-like expression for ion distributions that incorporates both the electrostatic potential and a novel hydrodynamic potential arising from the magnetic field. This potential depends explicitly on the flow profile and is not screened close to the bounding walls. Applying the theory to Poiseuille flow, we derive expressions for the induced Hall potential and demonstrate its near-linear dependence on flow velocity and magnetic field strength, while remaining largely independent of salt concentration. To validate this one-dimensional framework, we analyze the two-dimensional spatial transients near the channel entrance. We demonstrate a separation of length scales: the Hall electric field and space charge adjust to the magnetic field almost instantaneously, whereas the macroscopic salt concentration wake develops over a much longer Graetz length dictated by the Péclet number. We also examine a similar flow with counterions only and no added salt, determining the resulting potential and ion distributions. This work offers new theoretical tools for understanding ion transport in microfluidic and electrochemical systems.
Introduction
Magnetic fields play a pivotal role in a wide range of scientific and engineering domains. From fusion reactors and metallurgical processes to microfluidic devices and electrochemical systems to plasma accelerators and astrophysics, the Lorentz force facilitates controlling fluid motion, enhancing mass and heat transfer, mixing and vortex manipulation, and mitigating instabilities [1, 2, 3]. The Lorentz force can induce complex flow patterns, modify boundary layer behavior, and influence electrochemical reaction kinetics [1, 4].
In electrochemical systems, magnetic fields have been harnessed to improve electrodeposition uniformity, suppress dendrite formation in batteries, and enhance mixing in microreactors. [4, 5] For instance, the application of a static magnetic field in zinc-air batteries has been shown to regulate ion transport and reduce surface roughness, thereby extending cycle life [5]. Similarly, magnetic-driven flows in microfluidic channels enable non-mechanical fluid control, which is critical for lab-on-a-chip technologies and biomedical diagnostics [1, 6, 7, 8].
Realistic flows are two- or three-dimensional and complex in nature and usually lack analytical solutions and even numerical ones are difficult to obtain. Here, we restrict ourselves to one-dimensional flows in magnetic fields, which offer better physical insight and are easier to analyze analytically. We consider steady unidirectional flow of dilute electrolytes in a perpendicular constant magnetic field. In standard magnetohydrodynamics for liquid metals, conductivity is typically uniform, and the highly mobile electrons lead to quasi-neutrality, effectively shrinking space-charge boundary layers to atomic scales [9, 10, 11, 12]. Here, dissolved ions drift with the embedding liquid and, in addition, experience a Lorentz force acting in the perpendicular direction. The ions’ density thus varies in space, leading to spatially non-uniform conductivity. In this system, the Lorentz and electric forces and the ions’ osmotic pressure affect the fluid flow, while the ionic density is dictated by their diffusion, drift with the flow, and the Lorentz force.
The assumption of unidirectional flow allows us to obtain analytical solutions to both the Navier-Stokes equation and the ionic density. Surprisingly, the Navier-Stokes equation sequentially decouples from the ions. The ionic density obeys a Boltzmann-like distribution depending on a hydrodynamic potential and the electrostatic potential. We apply this general result to a “Hall effect” in flowing electrolytes in channel flow to find the Hall potential and liquid velocity profile.
The remainder of the paper is organized as follows. In Section II, we formulate the general equations governing magneto-electrokinetic transport for a unidirectional flow. In Section III, we apply this framework to a salt-containing electrolyte in Hagen-Poiseuille flow, deriving the governing Poisson-Boltzmann equation and evaluating the induced transverse Hall potential. To rigorously justify the fully developed one-dimensional assumption, Section IV details the two-dimensional spatial transients near the channel entrance. § 1.4 extends the analysis to a counterion-only electrolyte between charged plates. Finally, concluding remarks are provided in § 1.5.
Magneto-electrokinetics of dilute electrolytes in unidirectional flow
We consider a dilute electrolyte flowing past one or more flat and smooth surfaces and subject to a perpendicular magnetic field. The coordinate system is such that is perpendicular to the surface, the flow is parallel to , and the magnetic field is (see Figure 1). The ions dissolved in the liquid are assumed to be point-like and symmetric; their charge and number densities are and for the cations and and for the anions. The incompressibility and Navier-Stokes equations for the pressure and flow velocity are
Figure 1. Illustration of electrolytes flowing in a slit under a perpendicular magnetic field. The electrolytes is confined by two flat solid surfaces at . Flow is unidirectional along , while the external magnetic field is . Cations and anions (colored spheres) are dissolved in the carrying liquid. Their number densities are and , respectively.
Here, is the liquid’s mass density, its viscosity, the charge density, the electric current density, the electric field, the Boltzmann constant and the absolute temperature. The sum on the right-hand side of Eq. (2) is due to the Lorentz force on moving charged ions,[13] while the last term is an osmotic pressure of dilute ideal gas of two ions with densities and . The electric field is not imposed by external potentials; rather, it arises self-consistently from nonuniform ion separation. We employ the so-called streaming current conditions, where the component of the field along the flow vanishes. Experimentally, this corresponds to a steady, continuous bulk fluid pumping by a pressure gradient through a channel with non-conducting (insulating) walls, which prevents external short-circuiting of the induced Hall current.
In the Nernst-Planck framework, the ionic densities obey the continuity equation
The ionic fluxes have three contributions:
The first one, , is due to the Lorentz force acting on the charges. The mobility , assumed equal for both ion types, obeys the Einstein relation , where is the diffusion constant [14, 15, 16, 17]. The second term, , is a diffusive flux of an ideal gas of ions. is a flux for advection with the flow.
For a system that is translationally invariant along (i.e., neglecting edge effects) and in unidirectional flow, the velocity and ion density depend on only: and . Ions are carried by the liquid in the direction and feel a perpendicular magnetic-origin force in the direction. Their number density is nonuniform in , leading to an electric field and osmotic pressure opposing the magnetic force. In steady state and in the absence of an electrochemical reaction at the bounding surfaces, these forces exactly cancel each other. Formally, the Nernst-Planck equation becomes . Since are independent of , we find
In the Navier-Stokes equation, the term vanishes identically as long as we are before turbulence, i.e., when the Reynolds number is sufficiently small. A tremendous simplification arises because the Lorentz and diffusive fluxes are oriented along – all body forces in the component vanish and Eq. (2) reduces to the Stokes equation:
as if there were no magnetic or electric forces. There is a unique flow profile depending on the pressure gradient and other boundary conditions of the problem. In Sec. III we employ the specific Hagen-Poiseuille flow but at this point we do not use it.
We have achieved sequential decoupling between the flow profile and the ionic densities – once is known from Eq. (6), it can be substituted in Eq. (5) to obtain:
where
is a magnetic-field-dependent “hydrodynamic potential” that ions feel and is a constant related to conservation of the total ion number.
The hydrodynamic potential introduced in Eq. (8) contains the cumulative effect of the Lorentz force acting on ions as they are advected by the flow. Physically, it represents the work done by the magnetic field on a charged particle moving along the flow direction. Conceptually analogous non-equilibrium effective drift potentials have also been derived for externally driven soft-matter systems [18]. The potential depends explicitly on the velocity profile and is nonzero only in the presence of both flow and magnetic field. It introduces a directional bias in ion distribution; in the bulk, the magnetic and electric components of the Lorentz force cancel, allowing the electrostatic field to persist far from the boundary walls. This mechanism is central to the emergence of the Hall potential in flowing electrolytes and marks a departure from classical equilibrium-based screening models.
The electrostatic potential satisfies the Poisson’s equation . Substitution of from Eq. (7) then yields the following Poisson-Boltzmann equation
Note that even though the ions are not in thermodynamic equilibrium, they obey a Boltzmann-like distribution with a non-electrostatic contribution, , depending on the flow profile. The term appears due to the presence of magnetic field and vanishes in its absence. A second important point is that ions are not classically screened. They feel a long-range force whose range is dictated by the flow profile and is usually algebraic in the distance from the wall. This means the “electric double layer” in this problem is different from the usual one; anions and cations can be separated over large distances. The magnetic field does not typically exert strong forces (see estimate below), so actual differences in anion and cation density may not be large. Nonetheless, the length-scale characterizing the variations in can be significantly larger than the Debye screening length.
The boundary conditions for depend on the physical realization. In this work, we assume no imposed external potential across the channel. The potential results from the influence of the magnetic field solely, or due to surface charges on channels’ walls. This means that on the walls is zero or constant, respectively. In Secs. III and V we employ specific boundary conditions appropriate to the physical realization.
Before we look in detail on a specific flow problem, let us verify the validity of the assumption that the total magnetic field equals the external imposed field .
The assumption should hold if the field produced by the moving ions is sufficiently small. We start with the Maxwell’s equations:
Here, is the vacuum permeability and is the permittivity of the liquid. In our problem, the electrical conductivity is not constant and the field-consistent expression for the electrical current density is .
From Ampère’s law with Maxwell’s correction,
The operator identity allows to write
Parameter depends on only and , and therefore Eq. (11) has only a component. We write the magnetic field as where is the correction to the external field due to the moving ions. Equation (11) can be written as .
One can estimate from . For a typical flow velocity m/s and average ion density of mM, with monovalent ions of ( is the elementary charge), we find
or smaller, because in most locations . For small enough systems and large external magnetic fields ( T), and we may thus assume that is constant in space. With increasing values of the external field , becomes even smaller in comparison with . In concentrated electrolytes or ionic liquids where M and channel width cm, becomes comparable to , and cannot be neglected. Higher flow rates, with velocities of the order of several meters per second would also increase , but then the assumption of laminar flow does not hold.
In the next section we apply the formalism expressed in Eqs. (6), (7), (8) and (9) to the “Hall effect” in flowing electrolytes.
Hall effect in flowing electrolytes in Poiseuille flow
The discussion and derivation above apply to general unidirectional flows. One such flow occurs in the Hall effect in flowing electrolytes. Soon after the discovery of the Hall effect in 1879, there were attempts to realize it in electrolytes. Most early experiments failed or were heavily criticized for flaws. [19, 20, 21, 22, 23] An early theory by Donnan assumed anions and cations are advected in opposite directions due to a parallel electric field, hence yielding a weak Hall effect [24]. Years later, theoretical works dealt primarily with the calculation of the ions’ mobility in given crossed electric and magnetic fields [14, 15, 16, 17]. It is important to distinguish fluid motion driven by a parallel electric field from our hydrodynamic scenario: when cations and anions migrate in opposite directions, the transverse Lorentz force pushes both ion types in the same direction, leading to local salt accumulation but no leading-order charge separation. In contrast, in the pressure-driven hydrodynamic flow studied here, all ions are advected in the same direction. The Lorentz force therefore pushes cations and anions in opposite transverse directions, actively inducing a charge separation and the resulting Hall potential.
Starting in 1975 and led by the Japanese school [25, 26], researchers investigated the Hall effect in the context of electrochemical processes. These works examine ionic currents flowing perpendicular to the confining surfaces. The Lorentz force is thus parallel to the flow. Most of these studies do not solve the Poisson’s equation. Besides electrochemistry, [27, 28] modern works focus on magnetohydrodynamic pumping, where the Lorentz force acts parallel to a channel’s walls,[29, 30, 31, 32] or on heat transfer [33, 34].
We now look in detail at Hagen-Poiseuille flow of an electrolyte in a slit between two surfaces and subject to a perpendicular magnetic field. Two parallel and smooth surfaces are at . Their length in the direction, , is assumed sufficiently long to neglect edge effects. A pressure difference is applied along the slit, and the solution to Eq. (6) for laminar flow is the familiar parabolic profile
The hydrodynamic potential integral in Eq. (8) for Hagen-Poiseuille flow is
The confining surfaces are assumed electrically neutral. Possible materials that remain neutral in water are Teflon, polypropylene, polystyrene, and polyethylene. The electrostatic potential depends on only. One needs to solve Eq. (9) subject to the condition , which follows the Gauss’ theorem for uncharged surfaces. Experimentally, it corresponds to a channel made of, for example, plastic material, or a metal coated with thin layer of inert material. Other experimental configurations could also be considered, such as imposing a constant potential: , where denotes the potential drop across the channel walls, thereby establishing an average external electric field. Under the no-charge conditions assumed here, the electric field arises solely from the magnetic field and the motion of charges.
The potential is an anti-symmetric function of . The constant appearing in Eq. (9) can now be interpreted as the yet-unknown midplane concentration, . It is related to the average ion density via the material conservation integral
We now define the dimensionless field , electrostatic potential , and Debye length by
Further, length is scaled by the Debye length:
This rescaling of length in the governing equations allows us to resolve the steep concentration gradients within the nanometer-scale space-charge region, explicitly isolating the boundary layer behavior from the macroscopic bulk flow. The definition of as
allows us to write the Poisson-Boltzmann equation and its boundary conditions as
where the prime denotes differentiation with respect to the dimensionless coordinate . Equation (19) is an inhomogeneous ordinary differential equation with a location-dependent “force” term proportional to the magnetic field via . The nonlinear eigenvalue has a unique value for which satisfies both boundary conditions and the conservation integral. The eigenvalue quantifies the deviation of the midplane ion concentration from the average bulk concentration . It is smaller than unity, indicating ion depletion in the midplane and accumulation near the walls. Since the local conductivity depends on the ionic concentration, also serves as a proxy for the spatial variation in conductivity across the slit. In this sense, encapsulates both electrostatic and hydrodynamic contributions to ion transport and can be linked to measurable quantities such as the transverse Hall potential and local current density.
Before we solve this equation, let us look at . This parameter is the ratio between the energy of the Lorentz force integrated over the slit’s width and the thermal energy . What is its magnitude? When cm/s, , T, m and at room temperature, . In microfluidic systems is smaller and is correspondingly smaller. One can express using the Reynolds number as , where the dimensionless magnetic number is . Thus, to increase while keeping fixed, one needs to increase , that is, increase charge, viscosity or field, or reduce mass density or temperature.
The term in Eq. (19) is absent from classical Poisson-Boltzmann formulations. Ions feel a long-range force whose range is dictated by the flow profile, usually algebraic in the distance from the wall. This means that ions are not exponentially screened and the “electric double layer” is very different from the usual one; anions and cations can be separated over large distance. We emphasize that the fundamental Debye screening length remains an unchanged thermodynamic property of the electrolyte. While the magnetic field induces a macroscopic algebraic dependence in the bulk of the channel, the boundary layers at the walls remain exponential and are governed by the standard . The external force is not strong so actual differences in anion/cation density would not be large. Still, the length-scale is of the order of the conduit’s size. One should be careful when looking at exceedingly small or large slit widths in Eq. (19), because , and in parabolic flow . Hence is independent of .
When , Eq. (19) can be linearized as yielding
What is the Hall potential across the two sides of the slit? We anticipate is slightly smaller than unity; when it follows that . Converted back to values, the electrostatic potential is
The dependence on salt content appears solely through the small second term, . When this term can be neglected compared with unity, is independent of salt content and one finds the potential drop to be
When cm/s, T, and m, one finds mV independent of the amount of salt.
While this induced potential is seemingly small, it generates macroscopic, measurable effects. In fact, commercial electromagnetic flowmeters routinely and accurately infer fluid flux by measuring these exact transverse Hall potentials in the 1–10 mV range in aqueous flows [35, 36, 37]. Our theory provides the foundational micro-physics for this well-established industrial phenomenon.
Figure 2 shows the profiles as obtained numerically from Eq. (19) with varying values of (see legend). The dimensionless length is in the range with ; curves are shown for only since is anti-symmetric in . All curves start with (the potential in the midplane is zero) and decrease with distance. The surface value is negative and decreases with .
Figure 2. Dimensionless potential profiles for salt-containing electrolytes flowing in a slit under perpendicular magnetic field. They are numerical solutions of Eq. (19) for . Each curve corresponds to a different value of the scaled magnetic field (see legend), with the downward arrow indicating the direction of increasing . The profiles are antisymmetric about the midplane , where the potential is zero. As increases, the potential becomes more negative, indicating stronger ion depletion in the midplane and accumulation near the boundaries. This behavior reflects long-range ion separation, in contrast to classical electric double layers with exponential decay.
The nonlinear boundary value problem was solved using a standard shooting method. We utilized a Runge-Kutta scheme to integrate the ordinary differential equation from one boundary, while an iterative root-finding algorithm adjusted the initial conditions to satisfy the boundary condition at the opposite wall. To evaluate the numerical error for a given profile , we wrote Eq. (19) in the form , where left- and right-hand side are the two sides of the equation. The relative error is defined as , where is the machine precision. This prevents division by zero in regions where the right-hand side vanishes. For each calculated curve, was smaller than the given threshold (typically ). The errors at the boundaries, and , were similarly small.
The dimensionless potential is related to via Eq. (18), and is shown in Figure 3 (a) for the same values of and . Potential increases with the distance from the midplane. We stress that the electrostatic potential is not screened at the walls. The magnetic field exists everywhere within the gap between the surfaces and hence there is an electric field everywhere, not just at the surface. This is clearly seen as an almost linear increase in near the midplane (), indicating a constant electric field .
Figure 3. (a) Dimensionless electrostatic potential for different values of the scaled magnetic field , derived from the potential in Figure 2 using Eq. (18). The curves show how the potential increases away from the midplane, indicating a persistent electric field throughout the slit. The scaled magnetic field value is given by the legend (vertical arrow denotes increasing ). (b) Dimensionless Hall potential as a function of . The solid line shows numerical results, while the dashed line is the analytical approximation , highlighting the near linear dependence of the Hall potential on magnetic field strength.
Figure 3 (b) shows the Hall potential as a function of magnetic field strength. The Hall potential increase monotonically with . The dashed line is the approximation [see Eq. (22)].
To find the dependence of on for small values, we use the conservation integral with for , and from Eq. (20).
To lowest order this yields
The larger of the two values is the correct one, tending to unity in the limit . The smaller tends to zero in the same limit and cannot satisfy the material conservation integral in Eq. (19).
Although the influence of magnetic fields is often weak, it is instructive to look at the limit of exceedingly large fields. is negative and decreases with . In the limit where , is linear in : , where and are positive constants. The ion conservation integral in Eq. (19) is then dominated by , leading to
where is a dimensionless constant. That is, is exponentially small in .
The eigenvalue is plotted in Figure 4 as a function of magnetic field strength. When , there are no forces on ions and they are evenly distributed in the electrolytes. Hence their midplane density is and . As is increased, ions are pushed toward the walls and depleted from the midplane; correspondingly decreases. For small enough values of , decreases as a parabola, and the approximation of Eq. (23) (dashed line) holds well. At large values of , levels off, as it cannot be negative. The large limit is shown as a semi-log plot in the inset. The straight line is a manifestation of the exponential dependence of on . The dashed line is the approximation in Eq. (24).
Figure 4. The nonlinear eigenvalue versus scaled magnetic field for the same curves shown in Figure 2 and Figure 3. The solid line shows numerical values obtained from the Poisson–Boltzmann equation, while the dashed line is the small- approximation from Eq. (23). The inset shows a semi-log plot of at very large , revealing an exponential decay. Physically, decreasing indicates ion depletion in the midplane and enhanced accumulation near the walls. Line with symbols is , dashed line is from Eq. (24).
The ionic densities are plotted in Figure 5 for the whole range . The vertical axis is for cations and for anions. The dashed lines are for weak magnetic field while the solid lines are for the large value (see legend). These curves do not show exponential screening close to the surface at . Rather, they vary over macroscopic distance, comparable to the slit’s width.
Figure 5. Cation and anion number densities for two values of . The curves show how magnetic field alters the ion distribution: at higher , ions are pushed toward the walls, leading to long-range separation and deviation from classical electric double layer behavior.
Two-dimensional entrance effect and spatial transients
To validate the fully developed unidirectional flow assumption utilized in Secs. II and III, and to analytically estimate the entrance length required for the flow to become fully developed, we analyze the spatial transients near the entrance of the magnetic field region. We assume a unidirectional flow entering from the region where into the region where the magnetic field is acting. While the flow at the immediate inlet may deviate significantly from the fully developed state, we can extract the dominant spatial decay lengths governing the relaxation by performing an asymptotic spatial stability analysis. To do this, we linearize the ion densities , the electric potential , and the velocity field around the downstream unidirectional analytical solutions of the infinite channel derived in the previous sections, denoted by the subscript “1”. The base states satisfy the one-dimensional equilibrium inside the channel (). Specifically, the base velocity is the Poiseuille profile . The base ion densities are , and the normalized base potential is . The small two-dimensional spatial perturbations are denoted by :
Substituting these decompositions into the Nernst–Planck expression Eq. (4), the first-order perturbation flux for the cations, , is given by:
We further simplify this expression by exploiting the separation of time scales between momentum and mass transport. In aqueous electrolytes, the Schmidt number, , is typically very large (). This implies that the hydrodynamic profile establishes itself orders of magnitude faster than the concentration profile. We therefore assume and focus purely on the mass transport relaxation governed by .
The transverse component of the perturbed cation flux can now be written as:
Recall that the analytical base state is in transverse equilibrium, meaning that . Substituting this equilibrium condition back into the perturbation flux simplifies to:
This confirms that the mass transport perturbation is driven by the mismatch between local gradients, rather than directly by the magnitude of the Lorentz force.
Reduction to the Hall-Graetz problem
We now define the salt concentration perturbation and the charge density perturbation . To justify the decoupling of the charge density , we take the divergence of the difference between the linearized cation and anion fluxes, . By evaluating the electromigration terms and using the Poisson’s equation , we obtain a screened transport equation for the charge perturbation:
The charge equation contains a large volumetric sink term representing dielectric screening. By balancing the convective left-hand side of Eq. (29) with this screening sink, we extract the characteristic streamwise relaxation length for the charge perturbation: . Because the Debye length is microscopic compared with the channel width, this electrostatic adjustment is virtually instantaneous. It is orders of magnitude shorter than both the standard hydrodynamic entrance length () and the salt concentration Graetz length [38]. In the macroscopic bulk, this sink overwhelmingly dominates the diffusion term , forcing the bulk charge density perturbation to vanish almost immediately. At the walls, however, the convective left-hand side vanishes (), allowing transverse diffusion to balance the screening sink and leading to the creation of an electric double layer. In sum, does not exhibit a long downstream wake, but is instead confined to these exponential boundary layers. In the macroscopic bulk flow, the charge density rapidly converges to its fully developed state, making the assumption valid almost immediately.
The sum of the linearized fluxes for cations and anions, , yields:
The third term on the right-hand side is vanishingly small in the bulk because the Hall electric field establishes itself to oppose the magnetic drift. The fourth term is exponentially small as the base ion densities obey , and the base potential . Thus, . The divergence of the salt flux, , thus simplifies to the standard convection-diffusion balance. Neglecting streamwise diffusion, , we obtain the governing equation for the salt perturbation in the entrance region:
This classical Graetz formulation demonstrates that the macroscopic entrance length is dictated purely by mass transport scaling, largely independent of the complex electrostatic coupling.
Estimation of the entrance length
Because the Hall separation is antisymmetric with respect to the midplane, the salt perturbation is an even function of , and its first moment vanishes. To estimate the development length, we evaluate the second moment , representing the transverse variance of the concentration.
Multiplying the Graetz equation by and integrating across the channel, we define a variance-weighted effective velocity, . By invoking a self-similar concentration profile, , the -dependent amplitude cancels out of the ratio, rendering a strict constant independent of downstream distance:
Integration of the right-hand side by parts twice yields boundary terms and a residual integral. The no-flux boundary condition, at , leads to vanishing of the first boundary term. Evaluation of the second boundary term yields . Crucially, because the Hall effect redistributes ions without creating or destroying mass, global salt conservation dictates that the cross-sectional integral of the perturbation must vanish. The equation thus reduces to
Assuming a self-similar profile where the moment scales with the wall amplitude, , where is a dimensionless number of order unity, we extract a characteristic decay constant. The development length scales as:
where is the Péclet number.
The above analysis reveals a separation of length scales, demonstrating that the entrance region operates in two distinct kinematic stages:
The incompressible stage (electrostatic adjustment, ): Immediately upstream and downstream of the point where the magnetic window starts acting (), the concentration gradients are negligible (). In this region, the ion cloud behaves as an incompressible fluid. Because the bulk charge density has already relaxed to its fully developed profile (), Poisson’s equation reduces to Laplace’s equation for the perturbation potential. Solutions to Laplace’s equation in a strip dictate that the Hall potential generates fringing electric fields that decay over the geometric scale of the channel width, . Thus, the fields adjust to satisfy current conservation almost instantaneously, on the scale of the channel width, pre-accelerating ions transversely before they fully enter the magnetic region.
The compressible stage (concentration development, ): Over a much longer length scale, the transverse drift creates accumulation at the walls. In this second stage, the ion cloud becomes “compressible,” and the flux balance shifts to include the opposing force of diffusion. This concentration wake extends downstream over a macroscopic scale dictated by the Péclet number.
Therefore, while the minor amplitude modulations of the salt concentration require a long Graetz length to fully develop, the electric field and charge density adjust to the magnetic field almost instantaneously.
“Hall effect” in Poiseuille flow with only counterions
It is interesting to look at the “Hall effect” when there is no salt in the liquid. Rather, the walls of the slit become charged and release the counterions into the liquid. Many solid surfaces become charged when immersed in a polar solvent (like water) due to surface ionization, ion adsorption, or dissociation of surface groups. For example, in Silica (), surface silanol groups (Si-OH) can deprotonate in water, releasing and leaving negatively charged Si-O- groups. Alumina () can both protonate or deprotonate depending on pH, releasing either or . In polystyrene sulfonate beads, sulfonic acid groups dissociate in water, releasing . In carboxylated surfaces, carboxylic acid groups (-COOH) deprotonate to -COO-, releasing H. Even clay and minerals, such as montmorillonite and kaolinite, have surface hydroxyls and exchangeable cations (, , ) that can be released into solution.
The walls of the slit are negatively charged with Coulomb per unit area. The geometry of the problem is unchanged, only the boundary conditions for the electrostatic potential now read
In systems where charge regulation applies, this boundary condition will differ; in particular, close to the entry to the channel, the boundary condition will depend on the coordinate along the stream.
We use the same formalism and definitions Eqs. (16) and (18) to arrive at
Equation (36) is nonlinear and inhomogeneous as Eq. (19), but here is the scaled surface density and lengths are scaled by the Bjerrum length, defined as
In water at room temperature, where is the vacuum permittivity, nm if . When the surfaces are charged with single charge in every 10 nm10 nm square, the parameter is approximately unity. The nonlinear eigenvalue is defined as , where is the counterion density at the “left” plane ().
The appearance of only one exponent in the Poisson-Boltzmann equation reflects the existence of only cations in the liquid. The absence of mobile anions means the potential does not have a defined symmetry with respect to . The boundary conditions for the Poisson-Boltzmann problem in Eq. (36) are of Neumann type and hence addition of a constant to would just renormalize . We may therefore fix the gauge by replacing the condition by , and look for a unique value of without changing the counterion distribution or the physics.
It is instructive to first look at the solution when . Eq. (36) can then be integrated to give with a constant . Potential is symmetric when , and using the boundary condition, we find
where is the midplane potential. Since is positive, it follows that
For large values of , is larger than unity, and then .
In the absence of field, we recall the analytical solution of Eq. (36) for the semi-infinite domain with . The solution is
Length is the dimensionless Gouy-Chapman length; in physical units , and is chosen such that . The ion density varies algebraically: .
A second analytical solution of Eq. (36) exists when and the surfaces are uncharged: and . The solution is
We now turn to the general case where both and are non-zero. Figure 6 (a) shows for varying values of and fixed . Open circles show from Eq. (40) (). The dashed line is from Eq. (39) with and the largest surface charge density, . This value corresponds to one charge on a square of sides 160 nm160 nm, which is a low charge density. At these values the effect of magnetic field is significant. As increases from zero, the curves deviate from the circles, indicating that increases.
Figure 6. (a) Potential for counterion-only electrolytes flowing in a slit with , for varying surface charge densities . Open circles are the analytical expression Eq. (40) when and the dashed line is the analytical Eq. (39) when . (b) Nonlinear eigenvalue versus . The dashed line shows the analytical approximation , which becomes accurate at high surface charge. Inset: ratio approaches unity, confirming the approximation.
Figure 6 (b) shows that indeed increases monotonically with . Solid line is obtained numerically from Eq. (36). The dashed line is from Eq. (39). This approximation becomes increasingly accurate for large values of – the inset shows that the ratio tends to unity as increases.
Figure 7. (a) Dimensionless electrostatic potential corresponding to the curves in Figure 6 (a). Dashed horizontal line is the constant for the no-charge case. As surface charge increases, the potential becomes more concave. (b) Potential difference across the slit, , increases monotonically with surface charge.
Figure 7 shows the electrostatic potential corresponding to the curves in Figure 6 (a). When , is a constant. With increasing surface charge, becomes more concave. Figure 6 (b) shows the potential difference across the slit: . This difference varies monotonically with . When , the potential difference in physical units is 25 mV.
Conclusions
We have formulated a theoretical framework for magneto-electrokinetics in dilute electrolytes under unidirectional flow, combining the Navier–Stokes, Nernst–Planck, and Poisson equations into an analytically tractable system. Unlike classical liquid metals, where charge carriers are electrons and conductivity is typically uniform, our model accounts for spatially varying ion densities and additional forces such as osmotic pressure.
A key novelty is the sequential decoupling of hydrodynamics and electrostatics: the flow profile is governed solely by the Stokes equation, while ion distributions follow a Boltzmann-like law incorporating both electrostatic and hydrodynamic potentials. The latter, introduced here, arises from the Lorentz force and depends explicitly on the flow profile. The dissolved ions experience an algebraically decaying force and the nonlinear Poisson–Boltzmann equation includes this location-dependent forcing. As a result, the electric fields are not exponentially screened and can be significant even at channel-scale distances from the walls. These insights provide a new perspective on electrokinetic phenomena in magnetic fields and establish a foundation for analyzing coupled transport processes in electrolytes.
Applying the theory to Poiseuille flow, we derived the Hall potential induced by a transverse magnetic field and showed that it scales nearly linearly with flow velocity and magnetic field strength, while remaining approximately independent of salt concentration. The analysis also extends to counterion-only systems, where surface charge and magnetic forcing jointly shape ion distributions. In both cases, the model predicts measurable deviations from classical electrostatic screening and identifies a nonlinear eigenvalue that quantifies midplane ion depletion.
To validate this one-dimensional framework, we analyzed the two-dimensional spatial transients near the channel entrance. This analysis revealed a hierarchy of length scales, . The space charge relaxes almost immediately upon entry, . Consequently, the Hall electric field and potential adjust over the geometric scale of the channel width, , governed by Laplace’s equation. Both of these lengths are much smaller than the standard hydrodynamic momentum development length, . In contrast, the macroscopic salt concentration wake develops over a much larger Graetz length, , dictated by the Péclet number. This confirms that our steady-state one-dimensional framework captures the primary electrokinetic phenomena for the vast majority of the channel.
Experimental validation of the theoretical predictions is possible. For example, the expression for the surface potential in Eq. (22) can be tested by measuring the potential across two sides of the channel with fixed cross-section, while keeping constant and varying the pressure drop along the channel, thereby varying the flow rate and . Alternatively, the flow rate is kept fixed while the magnitude of the magnetic field is varied.
The present analysis can be extended to surfaces with charge regulation. For ionization of a surface group or adsorption at a single site, Markovich et al. [39] and Izzo et al. [40] showed how the effective surface charge density depends on the reaction’s activity and potential. In the present framework, one needs to solve a Poisson-Boltzmann equation with boundary conditions that depend in an algebraic way on the potential itself. Often, charge-regulation effects are weak so quantities such as the disjoining pressure should be examined on distances comparable to the Debye length . In Sec. III we assumed pure salt and in § 1.4 only counterions; it would be interesting to study cases where there are both dissolved salt and counterions, as even pure water contains some residual mobile charges.
Beyond the Hall effect, the present approach can be generalized to other geometries and flow conditions, including Couette and Taylor–Couette systems, and adapted to study electrochemical energy devices, microfluidic control, and magnetically-assisted desalination [41, 42]. Future work should address nonlinear flow regimes, transient dynamics, and experimental validation, as well as explore the interplay between magnetic fields and chemical reactions in confined electrolytes.
Acknowledgments
This work was supported by the Israel Science Foundation (ISF) grant no. 332/24.
References
- [1]H. H. Bau, Magnetochemistry 8, 140 (2022).
- [2]Z. M. Kaneaesamkandi, M. M. Shariff, K. N. Alammar, and R. D. Vilagines, Res. J. Appl. Sci. Eng. Technol. 4, 2412 (2012).
- [3]S. Qian and H. H. Bau, Mech. Res. Comm. 36, 10 (2009).
- [4]G. Salinas, C. Lozon, and A. Kuhn, Curr. Opin. Electrochem. 38, 101220 (2023).
- [5]P. Liang, Q. Li, L. Chen, Z. Tang, Z. Li, Y. Wang, Y. Tang, C. Han, Z. Lan, C. Zhi, and H. Li, J. Mater. Chem. A 10, 11841 (2022).
- [6]H. Farrokhi, D. O. Outaya, A. Khimchenko, and J. Dong, Nanofluid flow in porous media 203, 203 (2019).
- [7]T. S. Gregory, R. Cheng, G. Tang, L. Mao, and Z. T. H. Tse, Adv. Funct. Mater. 26, 3942 (2016).
- [8]E. A. Gebreyesus, A. Park, R. E. Guldberg, and K. G. Ong, Biomed. Phys. Eng. Express 9, 025007 (2023).
- [9]U. Müller and L. Bühler, Magnetofluiddynamics in channels and containers (Springer Science & Business Media, 2001).
- [10]L. D. Landau and E. M. Lifshitz, Electrodynamics of Continuous Media, Vol. 8 (Pergamon Press, 1984).
- [11]J. R. Melcher, Continuum Electromechanics (MIT Press, 1981).
- [12]R. F. Probstein, Physicochemical Hydrodynamics: An Introduction (John Wiley & Sons, 2003).
- [13]N. Ben-Shachar, J. T. Johnson, M. Madadi, D. R. Brumley, J. Nassios, and J. E. Sader, Phys. Rev. B 111, L121107 (2025).
- [14]W. L. Friedman, J. Phys. Chem. 69, 2617 (1965).
- [15]W. Sung and H. L. Friedman, J. Chem. Phys. 87, 643 (1987).
- [16]H. Kroh and B. Felderhof, Physica A: Statistical Mechanics and its Applications 153, 73 (1988).
- [17]H. J. Kroh and B. U. Felderhof, Mol. Phys. 70, 119 (1990), https://doi.org/10.1080/00268979000100881.
- [18]B. O Conchuir and A. Zaccone, Phys. Rev. E 87, 032310 (2013).
- [19]H. Bagard, Compt. Rend. de l’Acad. des Sci. Paris 122, 77 (1898).
- [20]H. Bagard, Il Nuovo Cimento (1895-1900) 7, 187–195 (1898).
- [21]P. Moretto, Il Nuovo Cimento (1901-1910) 3, 80 (1902).
- [22]G. Delvalez, J. Phys. Theor. Appl. 8, 360 (1909).
- [23]A. Oxley, Proc. R. Soc. London A. 88, 588–604 (1913).
- [24]F. G. Donnan, Proc. Phys. Soc. London 16, 244 (1897).
- [25]R. Aogaki, K. Fueki, and T. Mukaibo, Denki Kagaku oyobi Kogyo Butsuri Kagaku 43, 504 (1975).
- [26]R. Aogaki, K. Fueki, and T. Mukaibo, Denki Kagaku oyobi Kogyo Butsuri Kagaku 43, 509–514 (1975).
- [27]T. Z. Fahidy, J. Appl. Electrochem. 13, 553 (1983).
- [28]S. Qian and H. H. Bau, Phys. Fluids 17 (2005).
- [29]A. Homsy, S. Koster, J. C. T. Eijkel, A. van den Berg, F. Lucklum, E. Verpoorte, and N. F. de Rooij, Lab Chip 5, 466–471 (2005).
- [30]S. Chakraborty and D. Paul, J. Phys. D: Appl. Phys. 39, 5364 (2006).
- [31]M. Qin and H. H. Bau, Microfluid. Nanofluid. 10, 287 (2011).
- [32]M. Qin and H. H. Bau, Phys. Fluids 24, 037101 (2012).
- [33]A. L. Aboul-Hassan and H. A. Attia, Can. J. Phys. 80, 579–589 (2002).
- [34]H. A. Attia and A. L. Aboul-Hassan, Appl. Math. Mod. 27, 551 (2003).
- [35]R. C. Baker, Flow Measurement Handbook: Industrial Designs, Operating Principles, Performance, and Applications, 2nd ed. (Cambridge University Press, 2016).
- [36]Emerson Electric Co., About magnetic flow meters, https://www.emerson.com/en-us/automation/measurement-instrumentation/flow-measurement/about-magnetic (2026), accessed: 2026-03-31.
- [37]Yokogawa Electric Corporation, Magnetic flowmeters, https://www.yokogawa.com/solutions/products-and-services/measurement/field-instruments-products/flow-meters/magnetic-flowmeters/ (2026), accessed: 2026-03-31.
- [38]R. B. Bird, W. E. Stewart, and E. N. Lightfoot, Transport Phenomena, 2nd ed. (John Wiley & Sons, 2002).
- [39]T. Markovich, D. Andelman, and R. Podgornik, Europhys. Lett. 113, 26004 (2016).
- [40]D. Izzo, A. Bakhshandeh, and Y. Levin, J. Chem. Phys. 163, 064703 (2025).
- [41]P. Reinke, M. Schmidt, and T. Beckmann, Phys. Fluids 30, 509–514 (2018).
- [42]P. Brockmann, C. Symanczyk, X. Dong, Y. Kagathara, L. Corluka, and J. Hussong, Phys. Fluids 36, 112019 (2024).