betaFeedback

WorksPhysics and Astronomy

Theory of magneto-electrokinetics in unidirectional electrolyte flow: Hydrodynamic potential and Hall effect

Abstract

We develop a theoretical framework for magneto-electrokinetic transport in dilute electrolytes under unidirectional flow and streaming current conditions. Unlike standard magnetohydrodynamics in liquid metals, where charge carriers are electrons and conductivity is typically uniform, electrolytes exhibit spatially varying ion densities and additional forces such as osmotic pressure. In steady state, the coupled Navier–Stokes, Nernst–Planck, and Poisson equations become analytically tractable. We derive a Boltzmann-like expression for ion distributions that incorporates both the electrostatic potential and a novel hydrodynamic potential arising from the magnetic field. This potential depends explicitly on the flow profile and is not screened close to the bounding walls. Applying the theory to Poiseuille flow, we derive expressions for the induced Hall potential and demonstrate its near-linear dependence on flow velocity and magnetic field strength, while remaining largely independent of salt concentration. To validate this one-dimensional framework, we analyze the two-dimensional spatial transients near the channel entrance. We demonstrate a separation of length scales: the Hall electric field and space charge adjust to the magnetic field almost instantaneously, whereas the macroscopic salt concentration wake develops over a much longer Graetz length dictated by the Péclet number. We also examine a similar flow with counterions only and no added salt, determining the resulting potential and ion distributions. This work offers new theoretical tools for understanding ion transport in microfluidic and electrochemical systems.

Introduction

Magnetic fields play a pivotal role in a wide range of scientific and engineering domains. From fusion reactors and metallurgical processes to microfluidic devices and electrochemical systems to plasma accelerators and astrophysics, the Lorentz force facilitates controlling fluid motion, enhancing mass and heat transfer, mixing and vortex manipulation, and mitigating instabilities [1, 2, 3]. The Lorentz force can induce complex flow patterns, modify boundary layer behavior, and influence electrochemical reaction kinetics [1, 4].

In electrochemical systems, magnetic fields have been harnessed to improve electrodeposition uniformity, suppress dendrite formation in batteries, and enhance mixing in microreactors. [4, 5] For instance, the application of a static magnetic field in zinc-air batteries has been shown to regulate ion transport and reduce surface roughness, thereby extending cycle life [5]. Similarly, magnetic-driven flows in microfluidic channels enable non-mechanical fluid control, which is critical for lab-on-a-chip technologies and biomedical diagnostics [1, 6, 7, 8].

Realistic flows are two- or three-dimensional and complex in nature and usually lack analytical solutions and even numerical ones are difficult to obtain. Here, we restrict ourselves to one-dimensional flows in magnetic fields, which offer better physical insight and are easier to analyze analytically. We consider steady unidirectional flow of dilute electrolytes in a perpendicular constant magnetic field. In standard magnetohydrodynamics for liquid metals, conductivity is typically uniform, and the highly mobile electrons lead to quasi-neutrality, effectively shrinking space-charge boundary layers to atomic scales [9, 10, 11, 12]. Here, dissolved ions drift with the embedding liquid and, in addition, experience a Lorentz force acting in the perpendicular direction. The ions’ density thus varies in space, leading to spatially non-uniform conductivity. In this system, the Lorentz and electric forces and the ions’ osmotic pressure affect the fluid flow, while the ionic density is dictated by their diffusion, drift with the flow, and the Lorentz force.

The assumption of unidirectional flow allows us to obtain analytical solutions to both the Navier-Stokes equation and the ionic density. Surprisingly, the Navier-Stokes equation sequentially decouples from the ions. The ionic density obeys a Boltzmann-like distribution depending on a hydrodynamic potential UhydU_{\mathrm{hyd}} and the electrostatic potential. We apply this general result to a “Hall effect” in flowing electrolytes in channel flow to find the Hall potential and liquid velocity profile.

The remainder of the paper is organized as follows. In Section II, we formulate the general equations governing magneto-electrokinetic transport for a unidirectional flow. In Section III, we apply this framework to a salt-containing electrolyte in Hagen-Poiseuille flow, deriving the governing Poisson-Boltzmann equation and evaluating the induced transverse Hall potential. To rigorously justify the fully developed one-dimensional assumption, Section IV details the two-dimensional spatial transients near the channel entrance. § 1.4 extends the analysis to a counterion-only electrolyte between charged plates. Finally, concluding remarks are provided in § 1.5.

Magneto-electrokinetics of dilute electrolytes in unidirectional flow

We consider a dilute electrolyte flowing past one or more flat and smooth surfaces and subject to a perpendicular magnetic field. The coordinate system is such that x^\hat{x} is perpendicular to the surface, the flow is parallel to y^\hat{y}, and the magnetic field is B=B0z^\mathbf{B} = B_0\hat{\mathbf{z}} (see Figure 1). The ions dissolved in the liquid are assumed to be point-like and symmetric; their charge and number densities are qq and n+n^+ for the cations and −q-q and n−n^- for the anions. The incompressibility and Navier-Stokes equations for the pressure pp and flow velocity v\mathbf{v} are

Figure 1. Illustration of electrolytes flowing in a slit under a perpendicular magnetic field. The electrolytes is confined by two flat solid surfaces at x=±dx = \pm d. Flow is unidirectional along yy, while the external magnetic field is B=B0z^\mathbf{B} = B_0\hat{\mathbf{z}}. Cations and anions (colored spheres) are dissolved in the carrying liquid. Their number densities are n+n^+ and n−n^-, respectively.

∇⋅v=0,(1)\nabla\cdot\mathbf{v} = 0, \tag*{(1)}
ρ[∂v∂t+(v⋅∇)v]=−∇p+η∇2v+ρeE+j×B−kBT∇(n++n−).(2)\rho\left[\frac{\partial\mathbf{v}}{\partial t} + (\mathbf{v} \cdot\nabla)\mathbf{v}\right] = -\nabla p + \eta\nabla^2 \mathbf{v} + \rho_e \mathbf{E} + \mathbf{j} \times\mathbf{B} - k_B T \nabla(n^+ + n^-). \tag*{(2)}

Here, ρ\rho is the liquid’s mass density, η\eta its viscosity, ρe=q(n+−n−)\rho_e = q(n^+ - n^-) the charge density, j\mathbf{j} the electric current density, E\mathbf{E} the electric field, kBk_B the Boltzmann constant and TT the absolute temperature. The sum ρeE+j×B\rho_e\mathbf{E} + \mathbf{j} \times\mathbf{B} on the right-hand side of Eq. (2) is due to the Lorentz force on moving charged ions,[13] while the last term is an osmotic pressure of dilute ideal gas of two ions with densities n+n^+ and n−n^-. The electric field is not imposed by external potentials; rather, it arises self-consistently from nonuniform ion separation. We employ the so-called streaming current conditions, where the component of the field along the flow vanishes. Experimentally, this corresponds to a steady, continuous bulk fluid pumping by a pressure gradient through a channel with non-conducting (insulating) walls, which prevents external short-circuiting of the induced Hall current.

In the Nernst-Planck framework, the ionic densities obey the continuity equation

∂n±∂t+∇⋅h±=0.(3)\frac{\partial n^\pm}{\partial t} + \nabla\cdot\mathbf{h}^\pm= 0. \tag*{(3)}

The ionic fluxes h±=hL±+hd±+hadv±\mathbf{h}^\pm= \mathbf{h}_{\mathrm{L}}^\pm+ \mathbf{h}_{\mathrm{d}}^\pm+ \mathbf{h}_{\mathrm{adv}}^\pm have three contributions:

hL±=±n±μq(E+v×B),\mathbf{h}_{\mathrm{L}}^\pm= \pm n^\pm\mu q(\mathbf{E} + \mathbf{v} \times\mathbf{B}),
hd±=−D∇n±,\mathbf{h}_{\mathrm{d}}^\pm= -D\nabla n^\pm,
hadv±=n±v.(4)\mathbf{h}_{\mathrm{adv}}^\pm= n^\pm\mathbf{v}. \tag*{(4)}

The first one, hL\mathbf{h}_{\mathrm{L}}, is due to the Lorentz force fL=±q(E+v×B)\mathbf{f}_{\mathrm{L}} = \pm q(\mathbf{E} + \mathbf{v} \times\mathbf{B}) acting on the charges. The mobility μ\mu, assumed equal for both ion types, obeys the Einstein relation μ=D/kBT\mu= D/k_B T, where DD is the diffusion constant [14, 15, 16, 17]. The second term, hd\mathbf{h}_{\mathrm{d}}, is a diffusive flux of an ideal gas of ions. hadv\mathbf{h}_{\mathrm{adv}} is a flux for advection with the flow.

For a system that is translationally invariant along yy (i.e., neglecting edge effects) and in unidirectional flow, the velocity and ion density depend on xx only: v=v(x)y^\mathbf{v} = v(x)\hat{\mathbf{y}} and n±=n±(x)n^\pm= n^\pm(x). Ions are carried by the liquid in the yy direction and feel a perpendicular magnetic-origin force qv×Bq\mathbf{v}\times\mathbf{B} in the xx direction. Their number density is nonuniform in xx, leading to an electric field E=E(x)x^\mathbf{E} = E(x)\hat{\mathbf{x}} and osmotic pressure opposing the magnetic force. In steady state and in the absence of an electrochemical reaction at the bounding surfaces, these forces exactly cancel each other. Formally, the Nernst-Planck equation becomes ∇⋅h±=0\nabla\cdot\mathbf{h}^\pm= 0. Since h±\mathbf{h}^\pm are independent of yy, we find

±n±μq(E+v×B)−D∇n±=0.(5)\pm n^\pm\mu q(\mathbf{E} + \mathbf{v} \times\mathbf{B}) - D\nabla n^\pm= 0. \tag*{(5)}

In the Navier-Stokes equation, the term (v⋅∇)v=0(\mathbf{v} \cdot\nabla)\mathbf{v} = 0 vanishes identically as long as we are before turbulence, i.e., when the Reynolds number ReRe is sufficiently small. A tremendous simplification arises because the Lorentz and diffusive fluxes are oriented along xx – all body forces in the yy component vanish and Eq. (2) reduces to the Stokes equation:

−∂p∂y+η∂2v(x)∂x2=0(6)-\frac{\partial p}{\partial y} + \eta\frac{\partial^2 v(x)}{\partial x^2} = 0 \tag*{(6)}

as if there were no magnetic or electric forces. There is a unique flow profile v(x)v(x) depending on the pressure gradient and other boundary conditions of the problem. In Sec. III we employ the specific Hagen-Poiseuille flow but at this point we do not use it.

We have achieved sequential decoupling between the flow profile and the ionic densities – once v(x)v(x) is known from Eq. (6), it can be substituted in Eq. (5) to obtain:

n±(x)=nmexp⁡(∓qψ±Uhyd(x)kBT),(7)n^\pm(x) = n_m \exp\left(\frac{\mp q\psi\pm U_{\mathrm{hyd}}(x)}{k_B T}\right), \tag*{(7)}

where

Uhyd(x)≡q∫0xv(x′)B0 dx′(8)U_{\mathrm{hyd}}(x) \equiv q\int_{0}^{x} v(x')B_0\,dx' \tag*{(8)}

is a magnetic-field-dependent “hydrodynamic potential” that ions feel and nmn_m is a constant related to conservation of the total ion number.

The hydrodynamic potential Uhyd(x)U_{\mathrm{hyd}}(x) introduced in Eq. (8) contains the cumulative effect of the Lorentz force acting on ions as they are advected by the flow. Physically, it represents the work done by the magnetic field on a charged particle moving along the flow direction. Conceptually analogous non-equilibrium effective drift potentials have also been derived for externally driven soft-matter systems [18]. The potential UhydU_{\mathrm{hyd}} depends explicitly on the velocity profile and is nonzero only in the presence of both flow and magnetic field. It introduces a directional bias in ion distribution; in the bulk, the magnetic and electric components of the Lorentz force cancel, allowing the electrostatic field to persist far from the boundary walls. This mechanism is central to the emergence of the Hall potential in flowing electrolytes and marks a departure from classical equilibrium-based screening models.

The electrostatic potential ψ\psi satisfies the Poisson’s equation ∇2ψ=−(q/ε)(n+−n−)\nabla^2\psi= -(q/\varepsilon)(n^+ - n^-). Substitution of n±n^\pm from Eq. (7) then yields the following Poisson-Boltzmann equation

ψ′′=2qnmεsinh⁡(qψ−Uhyd(x)kT).(9)\psi'' = \frac{2qn_m}{\varepsilon}\sinh\left(\frac{q\psi-U_{\mathrm{hyd}}(x)}{kT}\right). \tag*{(9)}

Note that even though the ions are not in thermodynamic equilibrium, they obey a Boltzmann-like distribution with a non-electrostatic contribution, UhydU_{\mathrm{hyd}}, depending on the flow profile. The term UhydU_{\mathrm{hyd}} appears due to the presence of magnetic field and vanishes in its absence. A second important point is that ions are not classically screened. They feel a long-range force whose range is dictated by the flow profile and is usually algebraic in the distance from the wall. This means the “electric double layer” in this problem is different from the usual one; anions and cations can be separated over large distances. The magnetic field does not typically exert strong forces (see estimate below), so actual differences in anion and cation density may not be large. Nonetheless, the length-scale characterizing the variations in n±(x)n^\pm(x) can be significantly larger than the Debye screening length.

The boundary conditions for ψ\psi depend on the physical realization. In this work, we assume no imposed external potential across the channel. The potential results from the influence of the magnetic field solely, or due to surface charges on channels’ walls. This means that ψ′\psi' on the walls is zero or constant, respectively. In Secs. III and V we employ specific boundary conditions appropriate to the physical realization.

Before we look in detail on a specific flow problem, let us verify the validity of the assumption that the total magnetic field B\mathbf{B} equals the external imposed field B0z^\mathbf{B}_0\hat{\mathbf{z}}.

The assumption should hold if the field produced by the moving ions is sufficiently small. We start with the Maxwell’s equations:

∇×E=−∂B∂t,B=μ0H,\nabla\times\mathbf{E}=-\frac{\partial\mathbf{B}}{\partial t},\qquad\mathbf{B}=\mu_0\mathbf{H},
∇×H=j+ε∂E∂t,∇⋅B=0.(10)\nabla\times\mathbf{H}=\mathbf{j}+\varepsilon\frac{\partial\mathbf{E}}{\partial t},\qquad\nabla\cdot\mathbf{B}=0. \tag*{(10)}

Here, μ0\mu_0 is the vacuum permeability and ε\varepsilon is the permittivity of the liquid. In our problem, the electrical conductivity is not constant and the field-consistent expression for the electrical current density is j=q(n+−n−)v(x)y^\mathbf{j}=q(n^+-n^- )v(x)\hat{\mathbf{y}}.

From Ampère’s law with Maxwell’s correction,

1μ0∇×(∇×B)=∇×(q(n+−n−)v).\frac{1}{\mu_0}\nabla\times(\nabla\times\mathbf{B})=\nabla\times\left(q(n^+-n^-)\mathbf{v}\right).

The operator identity ∇×(∇×B)=∇(∇⋅B)−∇2B\nabla\times(\nabla\times\mathbf{B})=\nabla(\nabla\cdot\mathbf{B})-\nabla^2\mathbf{B} allows to write

−1μ0∇2B=∇×(q(n+−n−)v).(11)-\frac{1}{\mu_0}\nabla^2\mathbf{B}=\nabla\times\left(q(n^+-n^-)\mathbf{v}\right). \tag*{(11)}

Parameter nn depends on xx only and ∇×v=v′(x)z^\nabla\times\mathbf{v}=v'(x)\hat{\mathbf{z}}, and therefore Eq. (11) has only a zz component. We write the magnetic field as B=B0z^+b\mathbf{B}=B_0\hat{\mathbf{z}}+\mathbf{b} where b=bz^\mathbf{b}=b\hat{\mathbf{z}} is the correction to the external field due to the moving ions. Equation (11) can be written as ∇2b=−μ0Q∂x((n+−n−)v)\nabla^2 b=-\mu_0Q\partial_x((n^+-n^- )v).

One can estimate bb from ∂b/∂x∼μ0qnv(x)\partial b/\partial x\sim\mu_0qnv(x). For a typical flow velocity v=0.1v=0.1 m/s and average ion density of n0=1n_0=1 mM, with monovalent ions of q=eq=e (ee is the elementary charge), we find

∂b∂x∼10−2 T/m(12)\frac{\partial b}{\partial x}\sim10^{-2}\ {\rm T/m} \tag*{(12)}

or smaller, because in most locations ∣n+−n−∣≪n0|n^+-n^-|\ll n_0. For small enough systems and large external magnetic fields (B0∼1B_0\sim1 T), b≪B0b\ll B_0 and we may thus assume that B=B0z^\mathbf{B}=B_0\hat{\mathbf{z}} is constant in space. With increasing values of the external field B0B_0, bb becomes even smaller in comparison with B0B_0. In concentrated electrolytes or ionic liquids where n0∼1n_0\sim1 M and channel width ∼10\sim10 cm, bb becomes comparable to B0B_0, and cannot be neglected. Higher flow rates, with velocities v0v_0 of the order of several meters per second would also increase bb, but then the assumption of laminar flow does not hold.

In the next section we apply the formalism expressed in Eqs. (6), (7), (8) and (9) to the “Hall effect” in flowing electrolytes.

Hall effect in flowing electrolytes in Poiseuille flow

The discussion and derivation above apply to general unidirectional flows. One such flow occurs in the Hall effect in flowing electrolytes. Soon after the discovery of the Hall effect in 1879, there were attempts to realize it in electrolytes. Most early experiments failed or were heavily criticized for flaws. [19, 20, 21, 22, 23] An early theory by Donnan assumed anions and cations are advected in opposite directions due to a parallel electric field, hence yielding a weak Hall effect [24]. Years later, theoretical works dealt primarily with the calculation of the ions’ mobility in given crossed electric and magnetic fields [14, 15, 16, 17]. It is important to distinguish fluid motion driven by a parallel electric field from our hydrodynamic scenario: when cations and anions migrate in opposite directions, the transverse Lorentz force pushes both ion types in the same direction, leading to local salt accumulation but no leading-order charge separation. In contrast, in the pressure-driven hydrodynamic flow studied here, all ions are advected in the same direction. The Lorentz force therefore pushes cations and anions in opposite transverse directions, actively inducing a charge separation and the resulting Hall potential.

Starting in 1975 and led by the Japanese school [25, 26], researchers investigated the Hall effect in the context of electrochemical processes. These works examine ionic currents flowing perpendicular to the confining surfaces. The Lorentz force is thus parallel to the flow. Most of these studies do not solve the Poisson’s equation. Besides electrochemistry, [27, 28] modern works focus on magnetohydrodynamic pumping, where the Lorentz force acts parallel to a channel’s walls,[29, 30, 31, 32] or on heat transfer [33, 34].

We now look in detail at Hagen-Poiseuille flow of an electrolyte in a slit between two surfaces and subject to a perpendicular magnetic field. Two parallel and smooth surfaces are at x=±dx = \pm d. Their length in the yy direction, LL, is assumed sufficiently long to neglect edge effects. A pressure difference Δp\Delta p is applied along the slit, and the solution to Eq. (6) for laminar flow is the familiar parabolic profile

v(x)=v0(1−(xd)2)y^,(13)\mathbf{v}(x) = v_0 \left(1 - \left(\frac{x}{d}\right)^2\right) \hat{\mathbf{y}}, \tag*{(13)}
v0=Δpd22ηL.v_0 = \frac{\Delta p d^2}{2\eta L}.

The hydrodynamic potential integral in Eq. (8) for Hagen-Poiseuille flow is

Uhyd(x)=qv0B0(x−13x3d2).(14)U_{\mathrm{hyd}}(x) = qv_0B_0 \left(x - \frac{1}{3}\frac{x^3}{d^2}\right). \tag*{(14)}

The confining surfaces are assumed electrically neutral. Possible materials that remain neutral in water are Teflon, polypropylene, polystyrene, and polyethylene. The electrostatic potential depends on xx only. One needs to solve Eq. (9) subject to the condition ψ′(x=±d)=0\psi'(x = \pm d) = 0, which follows the Gauss’ theorem for uncharged surfaces. Experimentally, it corresponds to a channel made of, for example, plastic material, or a metal coated with thin layer of inert material. Other experimental configurations could also be considered, such as imposing a constant potential: ψ(x=±d)=+V/2\psi(x = \pm d) = +V/2, where VV denotes the potential drop across the channel walls, thereby establishing an average external electric field. Under the no-charge conditions assumed here, the electric field arises solely from the magnetic field and the motion of charges.

The potential ψ\psi is an anti-symmetric function of xx. The constant nmn_m appearing in Eq. (9) can now be interpreted as the yet-unknown midplane concentration, nm=n(x=0)n_m = n(x = 0). It is related to the average ion density n0n_0 via the material conservation integral

∫−ddn±(x) dx=2n0d.(15)\int_{-d}^{d} n^{\pm}(x)\,dx = 2n_0d. \tag*{(15)}

We now define the dimensionless field B~\widetilde{B}, electrostatic potential ψ~\widetilde{\psi}, and Debye length λD\lambda_D by

B~=qv0B0dkBT,ψ~=qψkBT,λD2=εkBT2n0q2(16)\widetilde{B} = \frac{qv_0B_0d}{k_BT}, \qquad\widetilde{\psi} = \frac{q\psi}{k_BT}, \qquad\lambda_D^2 = \frac{\varepsilon k_BT}{2n_0q^2} \tag*{(16)}

Further, length is scaled by the Debye length:

x~=xλD,d~=dλD.(17)\widetilde{x} = \frac{x}{\lambda_D}, \qquad\widetilde{d} = \frac{d}{\lambda_D}. \tag*{(17)}

This rescaling of length in the governing equations allows us to resolve the steep concentration gradients within the nanometer-scale space-charge region, explicitly isolating the boundary layer behavior from the macroscopic bulk flow. The definition of ϕ\phi as

ϕ=ψ~−B~(x~d~−13(x~d~)3).(18)\phi= \widetilde{\psi} - \widetilde{B}\left(\frac{\widetilde{x}}{\widetilde{d}} - \frac{1}{3}\left(\frac{\widetilde{x}}{\widetilde{d}}\right)^3\right). \tag*{(18)}

allows us to write the Poisson-Boltzmann equation and its boundary conditions as

ϕ′′=λsinh⁡(ϕ)+2B~x~d~3,(19)\phi'' = \lambda\sinh(\phi) + \frac{2\widetilde{B}\widetilde{x}}{\widetilde{d}^3}, \tag*{(19)}
λ∫0d~cosh⁡(ϕ)dx~=d~,ϕ(x~=0)=0,ϕ′(x~=d~)=0,\lambda\int_{0}^{\widetilde{d}} \cosh(\phi)d\widetilde{x} = \widetilde{d}, \qquad\phi(\widetilde{x}=0)=0, \qquad\phi'(\widetilde{x}=\widetilde{d})=0,

where the prime denotes differentiation with respect to the dimensionless coordinate x~\widetilde{x}. Equation (19) is an inhomogeneous ordinary differential equation with a location-dependent “force” term proportional to the magnetic field via B~\widetilde{B}. The nonlinear eigenvalue λ=nm/n0\lambda= n_m/n_0 has a unique value for which ϕ\phi satisfies both boundary conditions and the conservation integral. The eigenvalue λ\lambda quantifies the deviation of the midplane ion concentration nmn_m from the average bulk concentration n0n_0. It is smaller than unity, indicating ion depletion in the midplane and accumulation near the walls. Since the local conductivity depends on the ionic concentration, λ\lambda also serves as a proxy for the spatial variation in conductivity across the slit. In this sense, λ\lambda encapsulates both electrostatic and hydrodynamic contributions to ion transport and can be linked to measurable quantities such as the transverse Hall potential and local current density.

Before we solve this equation, let us look at B~\widetilde{B}. This parameter is the ratio between the energy of the Lorentz force ∼qvB\sim qvB integrated over the slit’s width dd and the thermal energy kBTk_{B}T. What is its magnitude? When v0=1v_{0}=1 cm/s, q=2eq=2e, B0=0.1B_{0}=0.1 T, d=0.1d=0.1 m and at room temperature, B~≃0.008\widetilde{B}\simeq0.008. In microfluidic systems dd is smaller and B~\widetilde{B} is correspondingly smaller. One can express B~\widetilde{B} using the Reynolds number Re≡ρv0d/ηRe\equiv\rho v_{0}d/\eta as B~=MRe\widetilde{B}=MRe, where the dimensionless magnetic number is M≡qηB/ρkBTM\equiv q\eta B/\rho k_{B}T. Thus, to increase B~\widetilde{B} while keeping ReRe fixed, one needs to increase MM, that is, increase charge, viscosity or field, or reduce mass density or temperature.

The term 2B~x~/d~32\widetilde{B}\widetilde{x}/\widetilde{d}^{3} in Eq. (19) is absent from classical Poisson-Boltzmann formulations. Ions feel a long-range force whose range is dictated by the flow profile, usually algebraic in the distance from the wall. This means that ions are not exponentially screened and the “electric double layer” is very different from the usual one; anions and cations can be separated over large distance. We emphasize that the fundamental Debye screening length λD\lambda_{D} remains an unchanged thermodynamic property of the electrolyte. While the magnetic field induces a macroscopic algebraic dependence in the bulk of the channel, the boundary layers at the walls remain exponential and are governed by the standard λD\lambda_{D}. The external force is not strong so actual differences in anion/cation density would not be large. Still, the length-scale is of the order of the conduit’s size. One should be careful when looking at exceedingly small or large slit widths in Eq. (19), because B~=qv0B0d/kT\widetilde{B}=qv_{0}B_{0}d/kT, and in parabolic flow v0∼d2v_{0}\sim d^{2}. Hence B~/d~3\widetilde{B}/\widetilde{d}^{3} is independent of dd.

When B~/d~2≪1\widetilde{B}/\widetilde{d}^{2}\ll1, Eq. (19) can be linearized as ϕ′′≈λϕ+2B~x~/d~3\phi^{\prime\prime}\approx\lambda\phi+2\widetilde{B}\widetilde{x}/\widetilde{d}^{3} yielding

ϕ=2B~d~3λsinh⁡(λx~)λcosh⁡(λd~)−2B~d~3x~.(20)\phi=\frac{2\widetilde{B}}{\widetilde{d}^{3}\lambda}\frac{\sinh\left(\sqrt{\lambda}\widetilde{x}\right)}{\sqrt{\lambda}\cosh\left(\sqrt{\lambda}\widetilde{d}\right)}-\frac{2\widetilde{B}}{\widetilde{d}^{3}}\widetilde{x}. \tag*{(20)}

What is the Hall potential across the two sides of the slit? We anticipate λ\lambda is slightly smaller than unity; when d~≫1\widetilde{d}\gg1 it follows that ϕ(d~)≈−2B~/d~2\phi(\widetilde{d})\approx-2\widetilde{B}/\widetilde{d}^{2}. Converted back to ψ~\widetilde{\psi} values, the electrostatic potential is

ψ~(d~)≈23B~−2B~d~2λ.(21)\widetilde{\psi}(\widetilde{d})\approx\frac{2}{3}\widetilde{B}-\frac{2\widetilde{B}}{\widetilde{d}^{2}\lambda}. \tag*{(21)}

The dependence on salt content n0n_{0} appears solely through the small second term, B~/d~2\widetilde{B}/\widetilde{d}^{2}. When this term can be neglected compared with unity, ψ~(d~)≈2B~/3\widetilde{\psi}(\widetilde{d})\approx2\widetilde{B}/3 is independent of salt content and one finds the potential drop ψHall≡ψ(d)−ψ(−d)\psi_{\mathrm{Hall}}\equiv\psi(d)-\psi(-d) to be

ψHall≈43v0B0d.(22)\psi_{\mathrm{Hall}}\approx\frac{4}{3}v_{0}B_{0}d. \tag*{(22)}

When v0=1v_{0}=1 cm/s, B=1B=1 T, and d=0.1d=0.1 m, one finds ψHall≈1.3\psi_{\mathrm{Hall}}\approx1.3 mV independent of the amount of salt.

While this induced potential is seemingly small, it generates macroscopic, measurable effects. In fact, commercial electromagnetic flowmeters routinely and accurately infer fluid flux by measuring these exact transverse Hall potentials in the 1–10 mV range in aqueous flows [35, 36, 37]. Our theory provides the foundational micro-physics for this well-established industrial phenomenon.

Figure 2 shows the profiles ϕ(x~)\phi(\widetilde{x}) as obtained numerically from Eq. (19) with varying values of B~\widetilde{B} (see legend). The dimensionless length x~\widetilde{x} is in the range −d~≲x~≲d~-\widetilde{d}\lesssim\widetilde{x}\lesssim\widetilde{d} with d~=10\widetilde{d}=10; curves are shown for x~>0\widetilde{x}>0 only since ϕ(x~)\phi(\widetilde{x}) is anti-symmetric in x~\widetilde{x}. All curves start with ϕ(x~=0)=0\phi(\widetilde{x}=0)=0 (the potential in the midplane is zero) and decrease with distance. The surface value ϕ(d~)\phi(\widetilde{d}) is negative and decreases with B~\widetilde{B}.

Figure 2. Dimensionless potential profiles ϕ(x~)\phi(\widetilde{x}) for salt-containing electrolytes flowing in a slit under perpendicular magnetic field. They are numerical solutions of Eq. (19) for d~=10\widetilde{d}=10. Each curve corresponds to a different value of the scaled magnetic field B~\widetilde{B} (see legend), with the downward arrow indicating the direction of increasing B~\widetilde{B}. The profiles are antisymmetric about the midplane x~=0\widetilde{x}=0, where the potential is zero. As B~\widetilde{B} increases, the potential ϕ(d~)\phi(\widetilde{d}) becomes more negative, indicating stronger ion depletion in the midplane and accumulation near the boundaries. This behavior reflects long-range ion separation, in contrast to classical electric double layers with exponential decay.

The nonlinear boundary value problem was solved using a standard shooting method. We utilized a Runge-Kutta scheme to integrate the ordinary differential equation from one boundary, while an iterative root-finding algorithm adjusted the initial conditions to satisfy the boundary condition at the opposite wall. To evaluate the numerical error for a given profile ϕ(x~)\phi(\widetilde{x}), we wrote Eq. (19) in the form LHS=RHSLHS=RHS, where left- and right-hand side are the two sides of the equation. The relative error is defined as err=∣RHS−LHS∣/(∣RHS∣+ϵmach)err=|RHS-LHS|/(|RHS|+\epsilon_{\mathrm{mach}}), where ϵmach\epsilon_{\mathrm{mach}} is the machine precision. This prevents division by zero in regions where the right-hand side vanishes. For each calculated curve, ∣err∣|err| was smaller than the given threshold (typically 10−610^{-6}). The errors at the boundaries, ∣ϕ(x~=0)∣|\phi(\widetilde{x}=0)| and ∣ϕ′(x~=d~)∣|\phi^{\prime}(\widetilde{x}=\widetilde{d})|, were similarly small.

The dimensionless potential ψ~\tilde{\psi} is related to ϕ\phi via Eq. (18), and is shown in Figure 3 (a) for the same values of B~\tilde{B} and d~\tilde{d}. Potential ψ~\tilde{\psi} increases with the distance from the midplane. We stress that the electrostatic potential ψ~\tilde{\psi} is not screened at the walls. The magnetic field exists everywhere within the gap between the surfaces and hence there is an electric field everywhere, not just at the surface. This is clearly seen as an almost linear increase in ψ~\tilde{\psi} near the midplane (x~=0\tilde{x}=0), indicating a constant electric field E=−ψ′E=-\psi'.

Figure 3. (a) Dimensionless electrostatic potential ψ~(x~)\tilde{\psi}(\tilde{x}) for different values of the scaled magnetic field B~\tilde{B}, derived from the potential ϕ(x~)\phi(\tilde{x}) in Figure 2 using Eq. (18). The curves show how the potential increases away from the midplane, indicating a persistent electric field throughout the slit. The scaled magnetic field value is given by the legend (vertical arrow denotes increasing B~\tilde{B}). (b) Dimensionless Hall potential ψ~Hall=ψ~(d~)−ψ~(−d~)\tilde{\psi}_{\mathrm{Hall}}=\tilde{\psi}(\tilde{d})-\tilde{\psi}(-\tilde{d}) as a function of B~\tilde{B}. The solid line shows numerical results, while the dashed line is the analytical approximation ψ~Hall=4B~/3\tilde{\psi}_{\mathrm{Hall}}=4\tilde{B}/3, highlighting the near linear dependence of the Hall potential on magnetic field strength.

Figure 3 (b) shows the Hall potential ψ~Hall\tilde{\psi}_{\mathrm{Hall}} as a function of magnetic field strength. The Hall potential increase monotonically with B~\tilde{B}. The dashed line is the approximation ψ~Hall=4B~/3\tilde{\psi}_{\mathrm{Hall}}=4\tilde{B}/3 [see Eq. (22)].

To find the dependence of λ\lambda on B~\tilde{B} for small B~\tilde{B} values, we use the conservation integral λ∫0d~cosh⁡(ϕ)dx~=d~\lambda\int_{0}^{\tilde{d}}\cosh(\phi)d\tilde{x}=\tilde{d} with cosh⁡(ϕ)≈1+(1/2)ϕ2\cosh(\phi)\approx1+(1/2)\phi^2 for ∣ϕ∣≪1|\phi|\ll1, and ϕ\phi from Eq. (20).

To lowest order this yields

λ≈23(B~d~2)2,λ≈1−23(B~d~2)2.(23)\lambda\approx\frac{2}{3}\left(\frac{\tilde{B}}{\tilde{d}^{2}}\right)^{2}, \qquad\lambda\approx1-\frac{2}{3}\left(\frac{\tilde{B}}{\tilde{d}^{2}}\right)^{2}. \tag*{(23)}

The larger of the two values is the correct one, tending to unity in the limit B~→0\tilde{B}\to0. The smaller λ\lambda tends to zero in the same limit and cannot satisfy the material conservation integral in Eq. (19).

Although the influence of magnetic fields is often weak, it is instructive to look at the limit of exceedingly large fields. ϕ(d~)\phi(\tilde{d}) is negative and decreases with B~\tilde{B}. In the limit where B~≫d~2\tilde{B}\gg\tilde{d}^{2}, ϕ(d~)\phi(\tilde{d}) is linear in B~\tilde{B}: ϕ(d~)≈c1−c2B~\phi(\tilde{d})\approx c_{1}-c_{2}\tilde{B}, where c1c_{1} and c2c_{2} are positive constants. The ion conservation integral λ∫0d~cosh⁡(ϕ)dx~=d~\lambda\int_{0}^{\tilde{d}}\cosh(\phi)d\tilde{x}=\tilde{d} in Eq. (19) is then dominated by cosh⁡(ϕ(d~))\cosh(\phi(\tilde{d})), leading to

λ≈1αcosh⁡(ϕ(d~)),(24)\lambda\approx\frac{1}{\alpha\cosh(\phi(\tilde{d}))}, \tag*{(24)}

where 0≤α≤10\leq\alpha\leq1 is a dimensionless constant. That is, λ\lambda is exponentially small in B~\tilde{B}.

The eigenvalue λ\lambda is plotted in Figure 4 as a function of magnetic field strength. When B~=0\tilde{B}=0, there are no forces on ions and they are evenly distributed in the electrolytes. Hence their midplane density is nm=n0n_m=n_0 and λ=1\lambda=1. As B~\tilde{B} is increased, ions are pushed toward the walls and depleted from the midplane; λ\lambda correspondingly decreases. For small enough values of B~\tilde{B}, λ\lambda decreases as a parabola, and the approximation of Eq. (23) (dashed line) holds well. At large values of B~\tilde{B}, λ\lambda levels off, as it cannot be negative. The large B~\tilde{B} limit is shown as a semi-log plot in the inset. The straight line is a manifestation of the exponential dependence of λ\lambda on B~\tilde{B}. The dashed line is the approximation in Eq. (24).

Figure 4. The nonlinear eigenvalue λ\lambda versus scaled magnetic field B~\tilde{B} for the same curves shown in Figure 2 and Figure 3. The solid line shows numerical values obtained from the Poisson–Boltzmann equation, while the dashed line is the small-B~\tilde{B} approximation from Eq. (23). The inset shows a semi-log plot of λ\lambda at very large B~\tilde{B}, revealing an exponential decay. Physically, decreasing λ\lambda indicates ion depletion in the midplane and enhanced accumulation near the walls. Line with symbols is λ\lambda, dashed line is from Eq. (24).

The ionic densities are plotted in Figure 5 for the whole range −d~≤x~≤d~-\tilde{d} \le\tilde{x} \le\tilde{d}. The vertical axis is n+=λexp⁡(−ϕ)n^+ = \lambda\exp(-\phi) for cations and n−=λexp⁡(ϕ)n^- = \lambda\exp(\phi) for anions. The dashed lines are for weak magnetic field while the solid lines are for the large B~\tilde{B} value (see legend). These curves do not show exponential screening close to the surface at x~=±d~\tilde{x} = \pm\tilde{d}. Rather, they vary over macroscopic distance, comparable to the slit’s width.

Figure 5. Cation and anion number densities n±(x~)=λexp⁡(∓ϕ)n^\pm(\tilde{x}) = \lambda\exp(\mp\phi) for two values of B~\tilde{B}. The curves show how magnetic field alters the ion distribution: at higher B~\tilde{B}, ions are pushed toward the walls, leading to long-range separation and deviation from classical electric double layer behavior.

Two-dimensional entrance effect and spatial transients

To validate the fully developed unidirectional flow assumption utilized in Secs. II and III, and to analytically estimate the entrance length required for the flow to become fully developed, we analyze the spatial transients near the entrance of the magnetic field region. We assume a unidirectional flow entering from the y<0y < 0 region where B=0\mathbf{B} = 0 into the y>0y > 0 region where the magnetic field is acting. While the flow at the immediate inlet may deviate significantly from the fully developed state, we can extract the dominant spatial decay lengths governing the relaxation by performing an asymptotic spatial stability analysis. To do this, we linearize the ion densities n±n^\pm, the electric potential ψ\psi, and the velocity field u\mathbf{u} around the downstream unidirectional analytical solutions of the infinite channel derived in the previous sections, denoted by the subscript “1”. The base states satisfy the one-dimensional equilibrium inside the channel (y>0y > 0). Specifically, the base velocity is the Poiseuille profile u1(x)=v0[1−(x/d)2]y^\mathbf{u}_1(x) = v_0[1-(x/d)^2]\hat{\mathbf{y}}. The base ion densities are n1±(x)=λn0e∓ϕ1(x)n_1^\pm(x) = \lambda n_0 e^{\mp\phi_1(x)}, and the normalized base potential is qψ1/kBT≈B~[x/d−(x/d)3/3]q\psi_1/k_BT \approx\tilde{B}[x/d-(x/d)^3/3]. The small two-dimensional spatial perturbations are denoted by δ\delta:

n±(x,y)=n1±(x)+δn±(x,y),n^\pm(x,y)=n_1^\pm(x)+\delta n^\pm(x,y),
ψ(x,y)=ψ1(x)+δψ(x,y),\psi(x,y)=\psi_1(x)+\delta\psi(x,y),
u(x,y)=u1(x)+δu(x,y).(25)\mathbf{u}(x,y)=\mathbf{u}_1(x)+\delta\mathbf{u}(x,y). \tag*{(25)}

Substituting these decompositions into the Nernst–Planck expression Eq. (4), the first-order perturbation flux for the cations, δh+\delta\mathbf{h}^+, is given by:

δh+=−D∇δn+−qμδn+∇ψ1−qμn1+∇δψ+δn+u1+n1+δu+μq[δn+(u1×B0z^)+n1+(δu×B0z^)].(26)\delta\mathbf{h}^+=-D\nabla\delta n^+-q\mu\delta n^+\nabla\psi_1-q\mu n_1^+\nabla\delta\psi+\delta n^+\mathbf{u}_1+n_1^+\delta\mathbf{u} +\mu q\left[\delta n^+(\mathbf{u}_1\times\mathbf{B}_0\hat{\mathbf{z}})+n_1^+(\delta\mathbf{u}\times\mathbf{B}_0\hat{\mathbf{z}})\right]. \tag*{(26)}

We further simplify this expression by exploiting the separation of time scales between momentum and mass transport. In aqueous electrolytes, the Schmidt number, Sc=η/(ρD)Sc=\eta/(\rho D), is typically very large (Sc∼103Sc\sim10^3). This implies that the hydrodynamic profile establishes itself orders of magnitude faster than the concentration profile. We therefore assume δu≈0\delta\mathbf{u}\approx0 and focus purely on the mass transport relaxation governed by ∇⋅δh±=0\nabla\cdot\delta\mathbf{h}^\pm=0.

The transverse component of the perturbed cation flux can now be written as:

δhx+=−D∂δn+∂x+μqδn+(v1(x)B0−∂ψ1∂x)−qμn1+∂δψ∂x.(27)\delta h_x^+=-D\frac{\partial\delta n^+}{\partial x}+\mu q\delta n^+\left(v_1(x)B_0-\frac{\partial\psi_1}{\partial x}\right)-q\mu n_1^+\frac{\partial\delta\psi}{\partial x}. \tag*{(27)}

Recall that the analytical base state n1+(x)n_1^+(x) is in transverse equilibrium, meaning that −D∂n1+/∂x−qμn1+∂ψ1/∂x+μqn1+v1(x)B0=0-D\partial n_1^+/\partial x-q\mu n_1^+\partial\psi_1/\partial x+\mu qn_1^+v_1(x)B_0=0. Substituting this equilibrium condition back into the perturbation flux simplifies δhx+\delta h_x^+ to:

δhx+=−D∂δn+∂x+Dδn+∂(ln⁡n1+)∂x−qμn1+∂δψ∂x.(28)\delta h_x^+=-D\frac{\partial\delta n^+}{\partial x}+D\delta n^+\frac{\partial(\ln n_1^+)}{\partial x}-q\mu n_1^+\frac{\partial\delta\psi}{\partial x}. \tag*{(28)}

This confirms that the mass transport perturbation is driven by the mismatch between local gradients, rather than directly by the magnitude of the Lorentz force.

Reduction to the Hall-Graetz problem

We now define the salt concentration perturbation δC=δn++δn−\delta C=\delta n^++\delta n^- and the charge density perturbation δρ=δn+−δn−\delta\rho=\delta n^+-\delta n^-. To justify the decoupling of the charge density δρ\delta\rho, we take the divergence of the difference between the linearized cation and anion fluxes, ∇⋅(δh+−δh−)=0\nabla\cdot(\delta\mathbf{h}^+-\delta\mathbf{h}^-)=0. By evaluating the electromigration terms and using the Poisson’s equation ∇2δψ=−(q/ϵ)δρ\nabla^2\delta\psi=-(q/\epsilon)\delta\rho, we obtain a screened transport equation for the charge perturbation:

v1(x)∂δρ∂y=D∇2δρ−DλD2δρ.(29)v_1(x)\frac{\partial\delta\rho}{\partial y}=D\nabla^2\delta\rho-\frac{D}{\lambda_D^2}\delta\rho. \tag*{(29)}

The charge equation contains a large volumetric sink term −Dδρ/λD2-D\delta\rho/\lambda_D^2 representing dielectric screening. By balancing the convective left-hand side of Eq. (29) with this screening sink, we extract the characteristic streamwise relaxation length for the charge perturbation: Lρ∼v1λD2/D=dPeˊ(λD/d)2L_{\rho} \sim v_1\lambda_D^2/D=d\mathrm{P\acute{e}}(\lambda_D/d)^2. Because the Debye length is microscopic compared with the channel width, this electrostatic adjustment is virtually instantaneous. It is orders of magnitude shorter than both the standard hydrodynamic entrance length (Lhydro∼d ReL_{\mathrm{hydro}}\sim d\,Re) and the salt concentration Graetz length [38]. In the macroscopic bulk, this sink overwhelmingly dominates the diffusion term D∇2δρD\nabla^2\delta\rho, forcing the bulk charge density perturbation to vanish almost immediately. At the walls, however, the convective left-hand side vanishes (v1→0v_1\to0), allowing transverse diffusion to balance the screening sink and leading to the creation of an electric double layer. In sum, δρ\delta\rho does not exhibit a long downstream wake, but is instead confined to these exponential boundary layers. In the macroscopic bulk flow, the charge density rapidly converges to its fully developed state, making the assumption δρ≈0\delta\rho\approx0 valid almost immediately.

The sum of the linearized fluxes for cations and anions, δhsalt=δh++δh−\delta\mathbf{h}_{\mathrm{salt}}=\delta\mathbf{h}^{+}+\delta\mathbf{h}^{-}, yields:

δhsalt=−D∇δC+δCu1+μqδρ(u1×B0z^−∇ψ1)−μq(n1+−n1−)∇δψ.(30)\delta\mathbf{h}_{\mathrm{salt}}=-D\nabla\delta C+\delta C\mathbf{u}_1+\mu q\delta\rho(\mathbf{u}_1\times B_0\hat{\mathbf{z}}-\nabla\psi_1)-\mu q(n_1^{+}-n_1^{-})\nabla\delta\psi. \tag*{(30)}

The third term on the right-hand side is vanishingly small in the bulk because the Hall electric field establishes itself to oppose the magnetic drift. The fourth term is exponentially small as the base ion densities obey n1+−n1−=−2nmsinh⁡(ϕ1)n_1^{+}-n_1^{-}=-2n_m\sinh(\phi_1), and the base potential ϕ1∼(λD/d)2≪1\phi_1\sim(\lambda_D/d)^2\ll1. Thus, n1+≈n1−n_1^{+}\approx n_1^{-}. The divergence of the salt flux, ∇⋅δhsalt=0\nabla\cdot\delta\mathbf{h}_{\mathrm{salt}}=0, thus simplifies to the standard convection-diffusion balance. Neglecting streamwise diffusion, ∂y2≪∂x2\partial_y^2\ll\partial_x^2, we obtain the governing equation for the salt perturbation in the entrance region:

v1(x)∂δC∂y=D∂2δC∂x2.(31)v_1(x)\frac{\partial\delta C}{\partial y}=D\frac{\partial^2\delta C}{\partial x^2}. \tag*{(31)}

This classical Graetz formulation demonstrates that the macroscopic entrance length is dictated purely by mass transport scaling, largely independent of the complex electrostatic coupling.

Estimation of the entrance length

Because the Hall separation is antisymmetric with respect to the midplane, the salt perturbation δC\delta C is an even function of xx, and its first moment vanishes. To estimate the development length, we evaluate the second moment M2(y)=∫−ddx2δC(x,y) dxM_2(y)=\int_{-d}^{d}x^2\delta C(x,y)\,dx, representing the transverse variance of the concentration.

Multiplying the Graetz equation by x2x^2 and integrating across the channel, we define a variance-weighted effective velocity, veff≡∫−ddx2v1δC dx/∫−ddx2δC dxv_{\mathrm{eff}}\equiv\int_{-d}^{d}x^2v_1\delta C\,dx/\int_{-d}^{d}x^2\delta C\,dx. By invoking a self-similar concentration profile, δC(x,y)≈δCwall(y)f(x/d)\delta C(x,y)\approx\delta C_{\mathrm{wall}}(y)f(x/d), the yy-dependent amplitude cancels out of the ratio, rendering veffv_{\mathrm{eff}} a strict constant independent of downstream distance:

veffdM2(y)dy≈D∫−ddx2∂2δC∂x2 dx.(32)v_{\mathrm{eff}}\frac{dM_2(y)}{dy}\approx D\int_{-d}^{d}x^2\frac{\partial^2\delta C}{\partial x^2}\,dx. \tag*{(32)}

Integration of the right-hand side by parts twice yields boundary terms and a residual integral. The no-flux boundary condition, ∂δC/∂x=0\partial\delta C/\partial x=0 at x=±dx=\pm d, leads to vanishing of the first boundary term. Evaluation of the second boundary term yields −2dδCwall(y)-2d\delta C_{\mathrm{wall}}(y). Crucially, because the Hall effect redistributes ions without creating or destroying mass, global salt conservation dictates that the cross-sectional integral of the perturbation must vanish. The equation thus reduces to

veffdM2(y)dy≈−4Dd⋅δCwall(y).(33)v_{\mathrm{eff}}\frac{dM_2(y)}{dy}\approx-4Dd\cdot\delta C_{\mathrm{wall}}(y). \tag*{(33)}

Assuming a self-similar profile where the moment scales with the wall amplitude, M2≈γd3δCwallM_2\approx\gamma d^3\delta C_{\mathrm{wall}}, where γ\gamma is a dimensionless number of order unity, we extract a characteristic decay constant. The development length scales as:

Ldev∼veffd2D=dPeˊ(34)L_{\mathrm{dev}}\sim\frac{v_{\mathrm{eff}}d^2}{D}=d\mathrm{P\acute{e}} \tag*{(34)}

where Peˊ=veffd/D\mathrm{P\acute{e}}=v_{\mathrm{eff}}d/D is the Péclet number.

The above analysis reveals a separation of length scales, demonstrating that the entrance region operates in two distinct kinematic stages:

  1. The incompressible stage (electrostatic adjustment, L∼dL\sim d): Immediately upstream and downstream of the point where the magnetic window starts acting (∣y∣≲2d|y|\lesssim2d), the concentration gradients are negligible (δn≈0\delta n\approx0). In this region, the ion cloud behaves as an incompressible fluid. Because the bulk charge density has already relaxed to its fully developed profile (δρ≈0\delta\rho\approx0), Poisson’s equation reduces to Laplace’s equation ∇2δψ≈0\nabla^2\delta\psi\approx0 for the perturbation potential. Solutions to Laplace’s equation in a strip dictate that the Hall potential ψ\psi generates fringing electric fields that decay over the geometric scale of the channel width, y∼dy\sim d. Thus, the fields adjust to satisfy current conservation almost instantaneously, on the scale of the channel width, pre-accelerating ions transversely before they fully enter the magnetic region.

  1. The compressible stage (concentration development, Ldev∼PeˊdL_{\mathrm{dev}}\sim\mathrm{P\acute{e}}d): Over a much longer length scale, the transverse drift creates accumulation at the walls. In this second stage, the ion cloud becomes “compressible,” and the flux balance shifts to include the opposing force of diffusion. This concentration wake extends downstream over a macroscopic scale dictated by the Péclet number.

Therefore, while the minor amplitude modulations of the salt concentration require a long Graetz length to fully develop, the electric field and charge density adjust to the magnetic field almost instantaneously.

“Hall effect” in Poiseuille flow with only counterions

It is interesting to look at the “Hall effect” when there is no salt in the liquid. Rather, the walls of the slit become charged and release the counterions into the liquid. Many solid surfaces become charged when immersed in a polar solvent (like water) due to surface ionization, ion adsorption, or dissociation of surface groups. For example, in Silica (SiO2\mathrm{SiO}_2), surface silanol groups (Si-OH) can deprotonate in water, releasing H+\mathrm{H}^{+} and leaving negatively charged Si-O- groups. Alumina (Al2O3\mathrm{Al}_2\mathrm{O}_3) can both protonate or deprotonate depending on pH, releasing either OH−\mathrm{OH}^{-} or H+\mathrm{H}^{+}. In polystyrene sulfonate beads, sulfonic acid groups dissociate in water, releasing H+\mathrm{H}^{+}. In carboxylated surfaces, carboxylic acid groups (-COOH) deprotonate to -COO-, releasing H. Even clay and minerals, such as montmorillonite and kaolinite, have surface hydroxyls and exchangeable cations (Na+\mathrm{Na}^{+}, K+\mathrm{K}^{+}, Ca2+\mathrm{Ca}^{2+}) that can be released into solution.

The walls of the slit are negatively charged with −qσ-q\sigma Coulomb per unit area. The geometry of the problem is unchanged, only the boundary conditions for the electrostatic potential now read

ψ′(x=±d)=∓qσϵ.(35)\psi'(x=\pm d)=\mp\frac{q\sigma}{\epsilon}. \tag*{(35)}

In systems where charge regulation applies, this boundary condition will differ; in particular, close to the entry to the channel, the boundary condition will depend on the coordinate yy along the stream.

We use the same formalism and definitions Eqs. (16) and (18) to arrive at

ϕ′′=−λe−ϕ+2B~x~d~3,(36)\phi''=-\lambda e^{-\phi}+\frac{2\tilde{B}\tilde{x}}{\tilde{d}^{3}}, \tag*{(36)}
λ∫−d~d~e−ϕdx~=2σ~,ϕ′(x~=±d~)=∓σ~.\lambda\int_{-\tilde{d}}^{\tilde{d}}e^{-\phi}d\tilde{x}=2\tilde{\sigma},\qquad\phi'(\tilde{x}=\pm\tilde{d})=\mp\tilde{\sigma}.

Equation (36) is nonlinear and inhomogeneous as Eq. (19), but here σ~=lB2σ\tilde{\sigma}=l_{B}^{2}\sigma is the scaled surface density and lengths are scaled by the Bjerrum length, defined as

lB=q2ϵkBT.l_{B}=\frac{q^{2}}{\epsilon k_{B}T}.

In water at room temperature, ϵ≈80ϵ0\epsilon\approx80\epsilon_{0} where ϵ0\epsilon_{0} is the vacuum permittivity, lB≈9l_{B}\approx9 nm if q=eq=e. When the surfaces are charged with single charge in every 10 nm×\times10 nm square, the parameter σ~\tilde{\sigma} is approximately unity. The nonlinear eigenvalue is defined as λ≡lB3nL\lambda\equiv l_{B}^{3}n_{L}, where nLn_{L} is the counterion density at the “left” plane (x~=−d~\tilde{x}=-\tilde{d}).

The appearance of only one exponent in the Poisson-Boltzmann equation reflects the existence of only cations in the liquid. The absence of mobile anions means the potential does not have a defined symmetry with respect to x~\tilde{x}. The boundary conditions for the Poisson-Boltzmann problem in Eq. (36) are of Neumann type and hence addition of a constant to ϕ\phi would just renormalize λ\lambda. We may therefore fix the gauge by replacing the condition ϕ′(x~=−d~)=σ~\phi'(\tilde{x}=-\tilde{d})=\tilde{\sigma} by ϕ(x~=−d~)≡0\phi(\tilde{x}=-\tilde{d})\equiv0, and look for a unique value of λ\lambda without changing the counterion distribution or the physics.

It is instructive to first look at the solution when B~=0\tilde{B}=0. Eq. (36) can then be integrated to give (1/2)ϕ′2=λe−ϕ+c1(1/2)\phi'^2=\lambda e^{-\phi}+c_1 with a constant c1c_1. Potential ϕ(x~)\phi(\tilde{x}) is symmetric when B~=0\tilde{B}=0, and using the boundary condition, we find

e−ϕm=1−12σ~2λ,(37)e^{-\phi_m}=1-\frac{1}{2}\frac{\tilde{\sigma}^{2}}{\lambda}, \tag*{(37)}

where ϕm≡ϕ(x~=0)\phi_m\equiv\phi(\tilde{x}=0) is the midplane potential. Since e−ϕme^{-\phi_m} is positive, it follows that

λ>12σ~2.(38)\lambda>\frac{1}{2}\tilde{\sigma}^{2}. \tag*{(38)}

For large values of σ~\tilde{\sigma}, ϕm\phi_m is larger than unity, and then λ≳(1/2)σ~2\lambda\gtrsim(1/2)\tilde{\sigma}^{2}.

In the absence of field, we recall the analytical solution of Eq. (36) for the semi-infinite domain −d~≤x~≤0-\tilde{d}\leq\tilde{x}\leq0 with d~→∞\tilde{d}\to\infty. The solution is

ϕ=2ln⁡(x~+d~+b~)+ϕ0,(39)\phi=2\ln(\tilde{x}+\tilde{d}+\tilde{b})+\phi_{0}, \tag*{(39)}
b~=2σ~,λ=12σ~2,ϕ0=ln⁡(12λ).\tilde{b}=\frac{2}{\tilde{\sigma}},\qquad\lambda=\frac{1}{2}\tilde{\sigma}^{2},\qquad\phi_{0}=\ln\left(\frac{1}{2}\lambda\right).

Length b~\tilde{b} is the dimensionless Gouy-Chapman length; in physical units b=lBb~=2ϵkBT/σe2b=l_{B}\tilde{b}=2\epsilon k_{B}T/\sigma e^{2}, and ϕ0\phi_{0} is chosen such that ϕ(x~=−d~)=0\phi(\tilde{x}=-\tilde{d})=0. The ion density n+n^{+} varies algebraically: n+∼2(x~+d~+b~)−2n^{+}\sim2(\tilde{x}+\tilde{d}+\tilde{b})^{-2}.

A second analytical solution of Eq. (36) exists when B~>0\tilde{B}>0 and the surfaces are uncharged: σ~=0\tilde{\sigma}=0 and λ=0\lambda=0. The solution is

ϕ=B~(13(x~d~)3−x~d~)−23B~.(40)\phi=\tilde{B}\left(\frac{1}{3}\left(\frac{\tilde{x}}{\tilde{d}}\right)^{3}-\frac{\tilde{x}}{\tilde{d}}\right)-\frac{2}{3}\tilde{B}. \tag*{(40)}

We now turn to the general case where both B~\tilde{B} and σ~\tilde{\sigma} are non-zero. Figure 6 (a) shows ϕ(x~)\phi(\tilde{x}) for varying values of σ~\tilde{\sigma} and fixed B~=1\tilde{B}=1. Open circles show ϕ(x~)\phi(\tilde{x}) from Eq. (40) (σ~=0\tilde{\sigma}=0). The dashed line is ϕ(x~)\phi(\tilde{x}) from Eq. (39) with B~=0\tilde{B}=0 and the largest surface charge density, σ~=0.03\tilde{\sigma}=0.03. This value corresponds to one charge on a square of sides 160 nm×\times160 nm, which is a low charge density. At these values the effect of magnetic field is significant. As σ~\tilde{\sigma} increases from zero, the curves deviate from the circles, indicating that λ\lambda increases.

Figure 6. (a) Potential ϕ(x~)\phi(\tilde{x}) for counterion-only electrolytes flowing in a slit with d~=100\tilde{d}=100, for varying surface charge densities σ~\tilde{\sigma}. Open circles are the analytical expression Eq. (40) when σ~=0\tilde{\sigma}=0 and the dashed line is the analytical Eq. (39) when B~=0\tilde{B}=0. (b) Nonlinear eigenvalue λ\lambda versus σ~\tilde{\sigma}. The dashed line shows the analytical approximation (1/2)σ~2(1/2)\tilde{\sigma}^{2}, which becomes accurate at high surface charge. Inset: ratio λ/(1/2σ~2)\lambda/(1/2\tilde{\sigma}^{2}) approaches unity, confirming the approximation.

Figure 6 (b) shows that indeed λ\lambda increases monotonically with σ~\tilde{\sigma}. Solid line is λ\lambda obtained numerically from Eq. (36). The dashed line is (1/2)σ~2(1/2)\tilde{\sigma}^{2} from Eq. (39). This approximation becomes increasingly accurate for large values of σ~\tilde{\sigma} – the inset shows that the ratio λ/[(1/2)σ~2]\lambda/[(1/2)\tilde{\sigma}^{2}] tends to unity as σ~\tilde{\sigma} increases.

Figure 7. (a) Dimensionless electrostatic potential ψ~(x~)\tilde{\psi}(\tilde{x}) corresponding to the ϕ(x~)\phi(\tilde{x}) curves in Figure 6 (a). Dashed horizontal line is the constant ψ~=−2B~/3\tilde{\psi}=-2\tilde{B}/3 for the no-charge case. As surface charge increases, the potential becomes more concave. (b) Potential difference across the slit, Δψ~≡ψ~(d~)−ψ~(−d~)\Delta\tilde{\psi}\equiv\tilde{\psi}(\tilde{d})-\tilde{\psi}(-\tilde{d}), increases monotonically with surface charge.

Figure 7 shows the electrostatic potential ψ~(x~)\tilde{\psi}(\tilde{x}) corresponding to the curves in Figure 6 (a). When σ~=0\tilde{\sigma}=0, ψ~=−2B~/3\tilde{\psi}=-2\tilde{B}/3 is a constant. With increasing surface charge, ψ~\tilde{\psi} becomes more concave. Figure 6 (b) shows the potential difference across the slit: Δψ~≡ψ~(d~)−ψ~(−d~)\Delta\tilde{\psi}\equiv\tilde{\psi}(\tilde{d})-\tilde{\psi}(-\tilde{d}). This difference varies monotonically with σ~\tilde{\sigma}. When Δψ~=1\Delta\tilde{\psi}=1, the potential difference in physical units is 25 mV.

Conclusions

We have formulated a theoretical framework for magneto-electrokinetics in dilute electrolytes under unidirectional flow, combining the Navier–Stokes, Nernst–Planck, and Poisson equations into an analytically tractable system. Unlike classical liquid metals, where charge carriers are electrons and conductivity is typically uniform, our model accounts for spatially varying ion densities and additional forces such as osmotic pressure.

A key novelty is the sequential decoupling of hydrodynamics and electrostatics: the flow profile is governed solely by the Stokes equation, while ion distributions follow a Boltzmann-like law incorporating both electrostatic and hydrodynamic potentials. The latter, introduced here, arises from the Lorentz force and depends explicitly on the flow profile. The dissolved ions experience an algebraically decaying force and the nonlinear Poisson–Boltzmann equation includes this location-dependent forcing. As a result, the electric fields are not exponentially screened and can be significant even at channel-scale distances from the walls. These insights provide a new perspective on electrokinetic phenomena in magnetic fields and establish a foundation for analyzing coupled transport processes in electrolytes.

Applying the theory to Poiseuille flow, we derived the Hall potential induced by a transverse magnetic field and showed that it scales nearly linearly with flow velocity and magnetic field strength, while remaining approximately independent of salt concentration. The analysis also extends to counterion-only systems, where surface charge and magnetic forcing jointly shape ion distributions. In both cases, the model predicts measurable deviations from classical electrostatic screening and identifies a nonlinear eigenvalue λ\lambda that quantifies midplane ion depletion.

To validate this one-dimensional framework, we analyzed the two-dimensional spatial transients near the channel entrance. This analysis revealed a hierarchy of length scales, Lρ≪d≪Lhydro≪LdevL_{\rho} \ll d \ll L_{\mathrm{hydro}} \ll L_{\mathrm{dev}}. The space charge relaxes almost immediately upon entry, Lρ∼dPe(λD/d)2L_{\rho} \sim d\mathrm{Pe}(\lambda_D/d)^2. Consequently, the Hall electric field and potential adjust over the geometric scale of the channel width, L∼dL \sim d, governed by Laplace’s equation. Both of these lengths are much smaller than the standard hydrodynamic momentum development length, Lhydro∼dReL_{\mathrm{hydro}} \sim d\mathrm{Re}. In contrast, the macroscopic salt concentration wake develops over a much larger Graetz length, Ldev∼dPeL_{\mathrm{dev}} \sim d\mathrm{Pe}, dictated by the Péclet number. This confirms that our steady-state one-dimensional framework captures the primary electrokinetic phenomena for the vast majority of the channel.

Experimental validation of the theoretical predictions is possible. For example, the expression for the surface potential Δψ\Delta\psi in Eq. (22) can be tested by measuring the potential across two sides of the channel with fixed cross-section, while keeping B0B_0 constant and varying the pressure drop along the channel, thereby varying the flow rate and v0v_0. Alternatively, the flow rate is kept fixed while the magnitude of the magnetic field B0B_0 is varied.

The present analysis can be extended to surfaces with charge regulation. For ionization of a surface group or adsorption at a single site, Markovich et al. [39] and Izzo et al. [40] showed how the effective surface charge density depends on the reaction’s activity and potential. In the present framework, one needs to solve a Poisson-Boltzmann equation with boundary conditions that depend in an algebraic way on the potential itself. Often, charge-regulation effects are weak so quantities such as the disjoining pressure should be examined on distances comparable to the Debye length λD\lambda_D. In Sec. III we assumed pure salt and in § 1.4 only counterions; it would be interesting to study cases where there are both dissolved salt and counterions, as even pure water contains some residual mobile charges.

Beyond the Hall effect, the present approach can be generalized to other geometries and flow conditions, including Couette and Taylor–Couette systems, and adapted to study electrochemical energy devices, microfluidic control, and magnetically-assisted desalination [41, 42]. Future work should address nonlinear flow regimes, transient dynamics, and experimental validation, as well as explore the interplay between magnetic fields and chemical reactions in confined electrolytes.

Acknowledgments

This work was supported by the Israel Science Foundation (ISF) grant no. 332/24.

References

  1. [1]H. H. Bau, Magnetochemistry 8, 140 (2022).
  2. [2]Z. M. Kaneaesamkandi, M. M. Shariff, K. N. Alammar, and R. D. Vilagines, Res. J. Appl. Sci. Eng. Technol. 4, 2412 (2012).
  3. [3]S. Qian and H. H. Bau, Mech. Res. Comm. 36, 10 (2009).
  4. [4]G. Salinas, C. Lozon, and A. Kuhn, Curr. Opin. Electrochem. 38, 101220 (2023).
  5. [5]P. Liang, Q. Li, L. Chen, Z. Tang, Z. Li, Y. Wang, Y. Tang, C. Han, Z. Lan, C. Zhi, and H. Li, J. Mater. Chem. A 10, 11841 (2022).
  6. [6]H. Farrokhi, D. O. Outaya, A. Khimchenko, and J. Dong, Nanofluid flow in porous media 203, 203 (2019).
  7. [7]T. S. Gregory, R. Cheng, G. Tang, L. Mao, and Z. T. H. Tse, Adv. Funct. Mater. 26, 3942 (2016).
  8. [8]E. A. Gebreyesus, A. Park, R. E. Guldberg, and K. G. Ong, Biomed. Phys. Eng. Express 9, 025007 (2023).
  9. [9]U. Müller and L. Bühler, Magnetofluiddynamics in channels and containers (Springer Science & Business Media, 2001).
  10. [10]L. D. Landau and E. M. Lifshitz, Electrodynamics of Continuous Media, Vol. 8 (Pergamon Press, 1984).
  11. [11]J. R. Melcher, Continuum Electromechanics (MIT Press, 1981).
  12. [12]R. F. Probstein, Physicochemical Hydrodynamics: An Introduction (John Wiley & Sons, 2003).
  13. [13]N. Ben-Shachar, J. T. Johnson, M. Madadi, D. R. Brumley, J. Nassios, and J. E. Sader, Phys. Rev. B 111, L121107 (2025).
  14. [14]W. L. Friedman, J. Phys. Chem. 69, 2617 (1965).
  15. [15]W. Sung and H. L. Friedman, J. Chem. Phys. 87, 643 (1987).
  16. [16]H. Kroh and B. Felderhof, Physica A: Statistical Mechanics and its Applications 153, 73 (1988).
  17. [17]H. J. Kroh and B. U. Felderhof, Mol. Phys. 70, 119 (1990), https://doi.org/10.1080/00268979000100881.
  18. [18]B. O Conchuir and A. Zaccone, Phys. Rev. E 87, 032310 (2013).
  19. [19]H. Bagard, Compt. Rend. de l’Acad. des Sci. Paris 122, 77 (1898).
  20. [20]H. Bagard, Il Nuovo Cimento (1895-1900) 7, 187–195 (1898).
  21. [21]P. Moretto, Il Nuovo Cimento (1901-1910) 3, 80 (1902).
  22. [22]G. Delvalez, J. Phys. Theor. Appl. 8, 360 (1909).
  23. [23]A. Oxley, Proc. R. Soc. London A. 88, 588–604 (1913).
  24. [24]F. G. Donnan, Proc. Phys. Soc. London 16, 244 (1897).
  25. [25]R. Aogaki, K. Fueki, and T. Mukaibo, Denki Kagaku oyobi Kogyo Butsuri Kagaku 43, 504 (1975).
  26. [26]R. Aogaki, K. Fueki, and T. Mukaibo, Denki Kagaku oyobi Kogyo Butsuri Kagaku 43, 509–514 (1975).
  27. [27]T. Z. Fahidy, J. Appl. Electrochem. 13, 553 (1983).
  28. [28]S. Qian and H. H. Bau, Phys. Fluids 17 (2005).
  29. [29]A. Homsy, S. Koster, J. C. T. Eijkel, A. van den Berg, F. Lucklum, E. Verpoorte, and N. F. de Rooij, Lab Chip 5, 466–471 (2005).
  30. [30]S. Chakraborty and D. Paul, J. Phys. D: Appl. Phys. 39, 5364 (2006).
  31. [31]M. Qin and H. H. Bau, Microfluid. Nanofluid. 10, 287 (2011).
  32. [32]M. Qin and H. H. Bau, Phys. Fluids 24, 037101 (2012).
  33. [33]A. L. Aboul-Hassan and H. A. Attia, Can. J. Phys. 80, 579–589 (2002).
  34. [34]H. A. Attia and A. L. Aboul-Hassan, Appl. Math. Mod. 27, 551 (2003).
  35. [35]R. C. Baker, Flow Measurement Handbook: Industrial Designs, Operating Principles, Performance, and Applications, 2nd ed. (Cambridge University Press, 2016).
  36. [36]Emerson Electric Co., About magnetic flow meters, https://www.emerson.com/en-us/automation/measurement-instrumentation/flow-measurement/about-magnetic (2026), accessed: 2026-03-31.
  37. [37]Yokogawa Electric Corporation, Magnetic flowmeters, https://www.yokogawa.com/solutions/products-and-services/measurement/field-instruments-products/flow-meters/magnetic-flowmeters/ (2026), accessed: 2026-03-31.
  38. [38]R. B. Bird, W. E. Stewart, and E. N. Lightfoot, Transport Phenomena, 2nd ed. (John Wiley & Sons, 2002).
  39. [39]T. Markovich, D. Andelman, and R. Podgornik, Europhys. Lett. 113, 26004 (2016).
  40. [40]D. Izzo, A. Bakhshandeh, and Y. Levin, J. Chem. Phys. 163, 064703 (2025).
  41. [41]P. Reinke, M. Schmidt, and T. Beckmann, Phys. Fluids 30, 509–514 (2018).
  42. [42]P. Brockmann, C. Symanczyk, X. Dong, Y. Kagathara, L. Corluka, and J. Hussong, Phys. Fluids 36, 112019 (2024).

Paper details

vlnc:W_6z9k9gqy
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…