WorksComputer Science
BEACON: Learning Observation-Conditioned Starting Points for Guided Conditional Flow Matching in Microscopy
Abstract
Fluorescence microscopy drives much of modern life science, but accessible imaging setups often yield images degraded by out-of-focus light, limited resolution, and strong signal-dependent noise. Computational restoration can recover high-quality images from such data, enabling cheaper and faster imaging at lower light dose, provided biologically meaningful structures are preserved. Guided conditional flow matching has recently shown strong results for microscopy dehazing and computational super-resolution by learning distributions of plausible restorations. However, it pairs each clean target with an independent standard Gaussian sample, so the starting point of every training path does not leverage the degraded observation. This arbitrary noise–target coupling can produce conflicting velocity targets and makes the conditional velocity field harder to learn. We present BEACON, a st-of- daptive learned coupling for guided ditional flow matching, which learns an observation-conditioned base distribution. During training, a lightweight conditional noise model proposes starting points for each degraded input, and the candidate with the lowest flow-matching loss supervises both networks, while a KL term keeps the proposal close to the Gaussian prior. At inference, a single draw from the learned proposal is transported along the velocity field, requiring neither candidate selection nor the target. We evaluate BEACON on ten datasets spanning microscopy dehazing and computational super-resolution against 13 baseline families. BEACON achieves the best median perception–distortion rank for every pairing of a fidelity metric (PSNR, MicroMS-SSIM) with a perceptual metric (LPIPS, FID). Code and pretrained models will be released under a permissive license.
Introduction
Fluorescence microscopy restoration is an ill-posed inverse problem, where a single degraded observation may cor-

Figure 1. BEACON balances reconstruction fidelity and perceptual realism. (a,b) Degraded input and corresponding ground truth. (c) BEACON () reconstruction showing the MMSE estimate (upper-left) and a posterior sample (lower-right).
respond to multiple plausible high-quality reconstructions. This ambiguity arises from uncertainty in the acquired measurements, which can be constrained, but not necessarily eliminated, by structural priors learned from training data. Deterministic restoration methods, typically optimized using mean squared error (MSE), produce a single prediction that averages over plausible solutions, often resulting in overly smooth reconstructions. As established by the perception–distortion trade-off [3], optimizing for data fidelity (e.g., high PSNR) can come at the expense of perceptual realism (e.g., low LPIPS or FID), and vice versa. Generative Image Restoration (GIR) methods, such as diffusion models and conditional flow matching, address this ambiguity by learning a conditional distribution over plausible reconstructions, enabling posterior sampling and offering a means to balance data fidelity and perceptual realism [19].
Recently, Guided Conditional Flow Matching (GCFM), an iterative GIR method, has demonstrated strong performance in microscopy dehazing and computational super-resolution under severe noise conditions [18, 19], with a favorable position on the perception–distortion frontier. However, GCFM pairs each target with an independent Gaussian sample: the observation guides the velocity field but not the base–target assignment, which can produce conflicting velocity targets at similar intermediate states [9].
In this work, we introduce BEACON, which adds a lightweight Conditional Noise Model (CNM) that learns an observation-conditioned noise distribution to construct adaptive base–target couplings (Figure 2). During training, the CNM proposes candidate starting points for each degraded input–target pair, and the candidate with the lowest flow-matching loss supervises the velocity model, while KL regularization keeps the learned distribution close to a standard Gaussian prior. At inference, a single sample from the learned conditional distribution is transported through the velocity field, without best-of- selection or access to the target image. We evaluate BEACON on ten datasets for microscopy dehazing and computational super-resolution, jointly assessing reconstruction fidelity and perceptual realism.

Figure 2. Overview of the BEACON training framework. Given a degraded microscopy observation , the conditional noise model predicts spatially varying Gaussian parameters , from which candidate latents are sampled. Each candidate is linearly interpolated with the corresponding clean target to construct , where . The conditional flow model learns the associated velocity field by minimizing the flow-matching loss . A best-of- selection identifies the candidate with the minimum flow-matching loss, which is used to update the flow model through Optimizer 1. The conditional noise model is updated separately through Optimizer 2, using the selected flow-matching loss with gradients stopped through , together with a KL regularization term that constrains the learned conditional noise distribution toward the standard Gaussian prior. This alternating optimization encourages adaptive noise–target couplings while preserving the stochasticity of the latent distribution.
Related Work
Light microscopy image restoration. Deep Learning-based microscopy restoration uses image data to estimate structures obscured by noise, haze, or limited resolution. Deterministic models [5, 8, 20, 24, 25, 26] produce a single estimate, leaving ambiguity in the restoration unresolved [21]. Probabilistic approaches model alternative reconstructions, but operate in a single-step prediction mode [17, 22]. Recent generative iterative approaches like HAZEMATCHING and RESMATCHING apply guided conditional flow matching to dehazing and computational super-resolution, respectively [18, 19].
Data-dependent and learned couplings. In microscopy image restoration, conditioning on the degraded observation is essential to preserve fidelity to the underlying biological structures while generating perceptually realistic predictions [18, 19]. Beyond conditioning the velocity field, the choice of base–target coupling determines the probability paths used to supervise flow matching and influences the learned transport geometry. Prior work has explored optimal-transport-based couplings [16] and learned forward processes to reduce trajectory intersections and curvature [9, 10]. In particular, Lee et al. [10] learn a Gaussian base distribution conditioned on the target image, but without incorporating the degraded observation. SIFM [1] constructs data-dependent couplings using an explicit degradation operator and a prescribed noise level, which may be unknown or difficult to estimate in microscopy due to signal-dependent noise. Similarly, PMRF [13] relies on an additional MMSE estimator and a carefully tuned noise parameter.
Best-of- and explorative training. Our best-of- selection draws inspiration from Implicit Maximum Likelihood Estimation (IMLE) [11], which matches training examples to their nearest generated samples to encourage mode coverage, and Explorative Modeling [7], which optimizes the best among multiple candidates to mitigate mode averaging. Concurrent work on Competitive Flow Matching (CFM) [15] similarly employs winner-take-all training, but introduces auxiliary latent codes to produce multiple competing velocity predictions at a shared intermediate state, improving the quality–coverage trade-off in image generation. Unlike these approaches, BEACON performs the competition over source–target couplings rather than over velocity predictions, sampling candidate starting points from a source distribution conditioned on the degraded observation.
Methods
Problem definition. Following [18, 19], we consider paired microscopy observations of the same underlying biological sample , acquired under two imaging conditions and . The degraded input and high-quality target are drawn from the corresponding conditional image distributions. Depending on the task, represents a hazy or low-resolution microscopy measurement, while represents its non-hazy or high-resolution counterpart. Given paired training data , we seek a conditional generative model of . As in [18, 19], no explicit knowledge of the image degradation operator is required.
Guided Conditional Flow Matching
Guided conditional flow matching (GCFM) learns a continuous transport from a standard Gaussian base distribution to the target image distribution while conditioning the velocity field on the degraded measurement [1, 12]. Let denote a base sample and a time. A network estimates the measurement-guided marginal velocity along the linear interpolant by minimizing
where the expectation is over paired training images, independent , and sampled . In this standard construction, the base sample is independent of the observed pair, i.e. . Thus, the observation guides the velocity regression but does not influence which noise realization is paired with its target.
Why the noise–target coupling matters. Even though each path in Eq. (1) is straight, independently sampled base–target pairs can pass through similar intermediate states while prescribing different velocity targets [9]. Under squared-error regression, the population-optimal guided velocity is
Consequently, nearby or overlapping conditional trajectories with conflicting velocities contribute to an averaged marginal direction. Such intersections have been associated with increased curvature of learned generative trajectories [9, 16]. Lee et al. [9] further motivate learning the forward process by relating generative trajectory curvature to numerical integration error. This perspective inspires our adaptation of the base–target coupling; our selection criterion is the guided flow-matching loss rather than an explicit curvature penalty.
In microscopy restoration, the observed pair is physically meaningful because both images describe the same specimen. In contrast, assigning an independently drawn Gaussian realization to that pair is arbitrary. We therefore retain the experimental observation–target correspondence and adapt only the base–target assignment. Rather than a purely independent coupling, we investigate a measurement-aware coupling.
Beacon: Best-of- Adaptive Learned Coupling
Figure 2 illustrates the BEACON training framework, including the conditional noise model, best-of- candidate selection, and alternating updates of the flow and noise models.
BEACON learns a measurement-conditioned proposal over base samples and explores candidate couplings per paired training example. Each sampled base induces a candidate interpolation and velocity target; the candidate with the lowest current guided flow-matching error is used for the parameter update. The measured pair is never reassigned.
Conditional noise model. A conditional noise model predicts pixel-wise maps of the mean and the log-variance that define a diagonal Gaussian proposal, from which candidates are drawn by reparameterization with independent :
where denotes element-wise multiplication. The noise model shares the architecture of the velocity network, with its time input fixed to . Conditioning on thus influences both the proposal from which training paths are initiated and the predicted velocity field.
Candidate transport and best-of- selection. Inspired by nearest-sample matching in IMLE [11] and best-match training in Explorative Modeling [7], we explore multiple candidate base samples for each fixed observation–target pair and rank their induced paths by guided velocity-regression error. For each training pair and sampled time , the th candidate defines the interpolant , its guided flow-matching loss , and the best-of- (BoK) training objective
where the minimizing index is selected separately for each observation–target pair and the expectation also includes the random candidate perturbations. For , this objective uses a single sample from the learned proposal; fixing that proposal to recovers standard GCFM. The is treated as a discrete selection: the gradient flows through the selected candidate and its reparameterized path, not through the selection index itself.
Prior regularization. To regularize the conditional proposal toward a standard Gaussian prior, the proposal is updated with
where controls the balance between candidate-path compatibility and prior regularity. Conditional KL regularization does not guarantee that the aggregate proposal exactly equals . This is intended: the proposal may deviate from the prior where this lowers the selected flow-matching loss, while the KL term penalizes such deviations, including a collapse of towards zero.
Training and alternating optimization. Because an untrained velocity model provides unreliable candidate rankings, we first warm up using independent Gaussian base samples and the standard GCFM objective in Eq. (1). We then alternate optimization of the velocity and conditional noise networks. For each minibatch of size , the noise network predicts and once per degraded observation. The candidate noises, interpolants, and velocity targets are constructed in parallel. We fold the candidate dimension into the batch dimension so that all candidate paths can be evaluated by a batched velocity-model pass rather than a serial loop over .
The best candidate is selected per original minibatch item. With the proposal frozen, the velocity update minimizes with respect to ; with the velocity network frozen, the proposal update minimizes in Eq. (5) with respect to . The selected candidate is re-evaluated with the counterpart network fixed as needed for each update. Gradient flow through the reparameterization in Eq. (3) enables the proposal to adapt its mean and standard deviation. Nonselected candidates contribute no direct Best-of- gradient for that selection. Supp. Algorithm 1 summarizes the full training procedure.
Inference and posterior sampling. At test time, only is available. The conditional noise network is evaluated once per input, and a single is drawn from the learned proposal as in Eq. (3). We then integrate the guided ODE from to with uniform Euler steps, yielding the restored image .
Multiple plausible restorations are obtained by independently sampling the initial state and repeating the ODE integration. The mean of such predictions approximates the conditional mean of the model’s generated distribution, and their pixel-wise variation characterizes predictive variability.
Computational complexity. The additional cost of BEACON is incurred during training, where the velocity model scores candidate paths per example, so that training-time memory and velocity-model computation grow approximately linearly with . At inference, no selection is performed, and BEACON uses the same ODE steps as [18, 19] plus one proposal-network evaluation per input (Supp. Section S2).
Experiments
Datasets. We evaluate BEACON on microscopy dehazing (widefield-to-confocal-like predictions) from [18] and computational super-resolution under heavy noise from [19] to examine its use across two major restoration tasks in light microscopy. The datasets span biological structures and degradation regimes. We keep the same dataset splits and pre-processing (normalization regime) as mentioned in [18] and [19], respectively. For dehazing, we use the five datasets of [18]: Zebrafish, Organoids1, Organoids2, Microtubule, and Neuron. For super-resolution, we use the five datasets of [19]: CCP, ER, F-actin, MT, and MT-Noisy. MT-Noisy is derived from MT by applying the additional noise scheme introduced in [19]. Note that Microtubule (dehazing) and MT (super-resolution) are distinct datasets.
Baselines. We compare BEACON with deterministic restoration networks and variational, diffusion-based, and flow-based generative methods. HazeMatching and ResMatching [18, 19] provide the direct guided flow-matching comparisons for assessing the effect of adapting the base–target assignment. For all other baselines, we follow the implementation details mentioned in [18] and [19], respectively. Additional details related to baselines are given in Supp. Section S4.
Evaluation metrics. Restoration quality requires both fidelity and perceptual evaluation. We measure distortion using PSNR and MicroMS-SSIM, and perceptual quality using LPIPS and FID. To examine their trade-offs, we report PSNR–LPIPS, PSNR–FID, MicroMS-SSIM–LPIPS, and MicroMS-SSIM–FID pairs.
For a relative summary, we independently normalize distortion and perceptual scores to [0, 1], with lower values indicating better performance. The empirical ideal point (0, 0) combines the best observed score on each axis; it need not correspond to an attainable reconstruction. For method with normalized scores and , the combined summary score adds the distance to this point and the distance to the diagonal,
This score combines proximity to the empirical ideal with a penalty for imbalance between normalized errors (Figure 3). Because the penalty can increase when one metric improves, the score does not preserve all Pareto improvements and must be interpreted alongside the original metric pairs.

Figure 3. Illustration of the Normalized Ideal-Point Distance (NIPD) ranking metric. For each perception–distortion plot, the ideal point is defined by the best distortion and perceptual scores achieved independently among all compared methods. Both metrics are normalized to [0, 1], placing the ideal point at (0, 0). For each method, NIPD is computed as , where is the Euclidean distance to the ideal point and is the perpendicular distance to the diagonal representing equal normalized distortion and perceptual error. Lower NIPD scores indicate a more favorable perception–distortion trade-off.
We rank methods by ascending for each dataset and metric pair, then summarize ranks across the available test datasets separately for each metric pair. Missing dataset results are not imputed. These rankings depend on the compared methods and normalization; they summarize relative balance rather than absolute restoration quality.
Uncertainty calibration. BEACON enables stochastic posterior sampling by drawing different initial noise realizations from its learned observation-conditioned base distribution. To assess whether the resulting predictive uncertainty reflects the true reconstruction error, we evaluate the calibration of its posterior samples against high-quality ground-truth images. Following [2, 18], we estimate pixel-wise uncertainty from the variability across multiple predictions and group pixels into bins according to their predicted uncertainty. For each bin, we compute the root mean variance (RMV) and root mean squared error (RMSE), representing predicted uncertainty and observed reconstruction error, respectively. We then linearly calibrate RMV against RMSE and assess their agreement using reliability diagrams.
A well-calibrated model yields values close to the identity line (), indicating that higher predictive uncertainty corresponds to larger reconstruction errors. Further details related to calibration are provided in Supp. Section S3.
Implementation details. BEACON uses a U-Net [6] velocity network with 3.70M parameters and a smaller variant of the same architecture as the conditional noise network, with 234K parameters. Both networks are implemented in PyTorch [14] and trained for 200 epochs on NVIDIA V100 GPUs using the Adam optimizer with alternating updates. Before alternating training, we warm up the velocity network for one epoch using independently sampled samples from the standard Gaussian base distribution . We use training patches of size or and set the KL regularization weight to . The candidates are folded into the batch dimension for velocity evaluation. Inference samples one starting point from the proposal and integrates the guided ODE with steps. We use the torchCFM [23] library for interpolant computation and ODE integration. We use the same training, validation, and test sample counts as HAZEMATCHING [18] for dehazing and RESMATCHING [19] for super-resolution. Full training details are provided in Supp. Section S1.
Evaluation. Predictions on full-sized images use inner tiling [2], with the tile size matching the training patch size and a 50% overlap.
Results
Quantitative Results
We compare BEACON with the baselines across datasets and metric pairs to assess the effect of adaptive base–target assignment. Figure 4 summarizes the main quantitative comparison for , using dataset-wise perception–distortion ranks for all four metric pairs introduced in Section 4. Both BEACON and the task-specific RESMATCHING/HAZEMATCHING baselines are evaluated on ten datasets, where distortion metrics are computed on the MMSE () and perceptual metrics are computed for each individual prediction and then averaged over the number of samples as described in [18, 19]. Their comparison assesses the combined effect of the learned conditional proposal and best-of- selection relative to independent Gaussian initialization. Per-dataset scores for all methods are reported in Supp. Section S7. Compared with its direct guided flow-matching counterpart, BEACON improves PSNR on six of the ten datasets, is within 0.02 dB on three, and is lower on CCP ( dB). FID improves on seven datasets, most strongly on Zebrafish (2.17 0.62) and Organoids1 (0.91 0.24), and is worse on Neuron, ER, and F-actin. LPIPS is lower on four datasets and higher on six, with the largest increase on ER (0.222 0.273). The gains are most consistent for dehazing, where PSNR and FID improve on four of the five datasets, whereas results for super-resolution are mixed.
Figure 4. Aggregate perception–distortion rankings across microscopy restoration datasets. Distributions of Normalized Ideal-Point Distance (NIPD; Eq. (6)) ranks across datasets for four metric pairs: PSNR–FID (top-left), PSNR–LPIPS (top-right), MicroMS-SSIM–LPIPS (bottom-left), and MicroMS-SSIM–FID (bottom-right). Methods are ordered by median rank (lower is better), with distributions capturing dataset-wise variability. Annotations () indicate the number of datasets evaluated per method; BEACON and the task-specific HAZEMATCHING/RESMATCHING baselines cover all 10 datasets. BEACON (, bold black) achieves the lowest median rank across all four metric pairs and a lower mean rank than the guided flow-matching baselines in three of the four, with a marginally higher mean rank on MicroMS-SSIM–FID. Complete dataset-wise results are provided in Supp. Section S7.
In the aggregate ranking (Figure 4), BEACON attains the lowest median rank for all four metric pairs, while its mean rank is slightly worse than that of the guided flow-matching baseline for MicroMS-SSIM–FID.
The ranking therefore supports improved relative perception–distortion balance under the chosen score, rather than superiority on every individual metric. Rank distributions must also be interpreted in light of dataset coverage: some competing methods have results on only one or five datasets, whereas BEACON and the direct guided baseline each have ten. As discussed in § 4, the ranking depends on normalization and the compared methods and does not establish improvement on both original metric axes.
Qualitative Results
Figure 5 shows representative crops for two dehazing datasets (Organoids1, Zebrafish) and two super-resolution datasets (MT, ER), comparing BEACON with the four best-ranked competing methods on each dataset. On these crops, the MMSE estimate of BEACON reaches the highest PSNR among the shown methods on Organoids1, Zebrafish, MT, and ER, and its posterior sample the lowest LPIPS on MT and ER and the tied-lowest on Zebrafish. Visually, BEACON recovers distinct punctate signals and thin filamentous extensions in Organoids1 while suppressing diffuse background fluorescence, resolves individual microtubule filaments and their crossings in MT, and reconstructs the interconnected tubular ER network including narrow branches and junctions.

Figure 5. Qualitative results. We show representative restoration results for four datasets: (A) Organoids1, (B) Zebrafish, (C) Microtubules (MT, super-resolution), and (D) Endoplasmic Reticulum (ER). For each dataset, we show (a) the full degraded input (1024 × 1024 or 1004 × 1004) with a selected crop (128 × 128, yellow box), (b) the degraded crop, (c) the corresponding ground truth, (d–g) predictions from the four best competing methods by median perception–distortion rank (see § 4), and (h) BEACON. For generative posterior models, diagonally split images show a representative posterior sample and the corresponding MMSE estimate, with sample LPIPS and MMSE PSNR reported, respectively. For point-predicting methods, PSNR and LPIPS are reported directly. Additional results are provided in Supp. § 15.
Although we employ inner tiling [2] to mitigate boundary artifacts, some tiling artifacts remain visible in the reconstructed images. Future work could explore adapting approaches such as SWT i [4] to further reduce these artifacts and improve spatial consistency across tile boundaries. FID, whereas and reach lower medians for MicroMS-SSIM–LPIPS. has the highest median rank in all four pairs, and the ordering of intermediate values is not monotonic in . With a single training run per setting, differences between neighboring values of should not be over-interpreted; notably, , which uses the learned proposal without candidate selection, remains competitive throughout.
Ablations and Analysis
We analyze the effect of the number of candidates and whether best-of- selection alone explains the gains of BEACON.
Choice of . We evaluate different values across all 10 validation datasets (Supp. Figure S5.4). achieves both the highest average PSNR (30.84 dB) and lowest average FID (0.4373). We therefore use BEACON with for all main results, although differences between values of are small.
Figure S5.4. Effect of the number of candidates (). Average validation PSNR (higher is better) and FID (lower is better) across all 10 datasets for different values of . Both metrics achieve their best average values at , with a PSNR of 30.84 dB and an FID of 0.4373. Differences between values of are small, and neither metric varies monotonically with . We therefore select for all experiments reported in the main paper.
Number of candidates on test data. Increasing expands candidate exploration but also increases training cost. We compare with under the learned proposal on the test data to assess the contribution of best-of- selection, using (Supp. Figure S5.1), with ranks computed against the full set of compared methods. attains the lowest or tied-lowest median rank for PSNR–FID, PSNR–LPIPS, and MicroMS-SSIM–LPIPS. and reach lower medians for MicroMS-SSIM–LPIPS. has the highest median rank in all four pairs, and the ordering of intermediate values is not monotonic in . With a single training run per setting, differences between neighboring values of should not be over-interpreted; notably, , which uses the learned proposal without candidate selection, remains competitive throughout.
Figure S5.1. Rank distributions of BEACON variants across the ten test datasets. We evaluate the effect of varying the number of noise candidates () on BEACON’s perception–distortion performance across four metric pairs: PSNR–LPIPS (top-left), PSNR–FID (top-right), MicroMS-SSIM–LPIPS (bottom-left), and MicroMS-SSIM–FID (bottom-right), using LPIPS (Ind) and FID (Ind). For each dataset, the empirical ideal point used to compute the NIPD score is determined from all available methods, including competing baselines and all BEACON variants evaluated here. Consequently, the displayed BEACON variants retain their ranks relative to the full set of competing methods, rather than being ranked exclusively against one another (see § 4). Each box summarizes the ranks across the ten test datasets. The annotation indicates the number of contributing datasets. Variants are ordered by median rank, with mean rank used to break ties. Lower ranks indicate a more favorable perception–distortion trade-off, while narrower boxes reflect greater consistency across datasets. For reference, we have shown how HAZEMATCHING/RESMATCHING compares with different variants of BEACON.
Learned base distribution. Supp. Figure S5.3 visualizes the learned proposal () on three representative Zebrafish patches. The predicted variance maps exhibit spatial structure correlated with the underlying morphology, with lower variance at prominent cellular structures, while the predicted mean remains close to zero.
Figure S5.3. Spatially adaptive noise distributions learned by BEACON. Visualization of the learned conditional noise model on three representative patches from the Zebrafish dataset with . Each row shows the degraded observation , the corresponding ground truth , the predicted mean , the predicted variance , and one sampled noise realization. Although individual noise samples appear visually similar to random Gaussian noise, the predicted variance maps exhibit spatial structure correlated with the underlying morphology, assigning lower variance to prominent cellular structures, while the predicted mean stays close to zero (note its scale). The learned proposal thus spatially modulates the noise scale. The bottom panel compares the empirical distributions of sampled noise (averaged over five draws, with standard deviation) against the standard Gaussian . The learned noise distributions are more concentrated around zero, illustrating how BEACON departs from an isotropic Gaussian prior to construct observation-dependent initializations for conditional flow matching.
Effect of best-of- on baseline methods. To assess whether Best-of- training alone explains the improvements of BEACON, we incorporate the same candidate selection strategy () into HAZEMATCHING and RESMATCHING while retaining their standard Gaussian initialization. Although this improves the baselines in some metric pairs, BEACON achieves lower median ranks than the Best-of- baselines in two comparisons (PSNR–LPIPS and PSNR–FID) and ties their median ranks in the other two (MicroMS-SSIM–LPIPS and MicroMS-SSIM–FID), although its mean ranks are slightly higher on the latter. This suggests that learning an observation-conditioned base distribution provides additional benefits beyond Best-of- selection for PSNR-based perception–distortion trade-offs, while improvements are not uniform across metrics. A detailed comparison is provided in Supp. Fig. S5.2.
Inference-step ablation. Similar to HAZEMATCHING and RESMATCHING [18, 19], BEACON allows users to adjust the number of inference steps without retraining, thereby varying the Euler step size and the resulting perception–distortion trade-off. Users can choose fewer or more steps according to their preference for perceptual quality or reconstruction fidelity, with the corresponding operating points assessed using LPIPS and PSNR, respectively. Supp. § 12.3 considers this trade-off on two datasets, comparing BEACON () with the corresponding HAZEMATCHING and RESMATCHING baselines.
Calibration Analysis
Predictive variation does not by itself establish calibrated uncertainty. Figure 6 evaluates BEACON with on two dehazing datasets (Organoids1 and Organoids2) and two super-resolution datasets (MT and ER), using the binned RMV–RMSE protocol in § 4. We compare the native uncertainty estimates with those obtained after linear calibration, with the identity line indicating agreement between predicted variability and observed reconstruction error.
Figure 6. Uncertainty calibration of BEACON () across two restoration tasks. The top row shows microscopy dehazing on Organoids1 (left) and Organoids2 (right); the bottom row shows super-resolution on MT (left) and ER (right). Following § 4, pixels are grouped by predicted uncertainty, and each point compares the root mean variance (RMV, horizontal axis) of posterior predictions with the observed root mean squared error (RMSE, vertical axis) in a bin. Blue curves show unscaled uncertainty estimates, and orange curves show estimates after linear calibration (“Scaled”); the fitted scale and offset are printed below each panel. The black dashed identity line () indicates agreement between predicted uncertainty and reconstruction error: points above it indicate underestimated uncertainty, while points below it indicate overestimated uncertainty. Calibration brings the organoid curves closer to the identity line over much of the displayed range, while residual deviations remain for ER and MT, showing that a global linear correction does not ensure agreement in every uncertainty bin.
For both organoid datasets, the unscaled curves increasingly lie above the identity line as uncertainty grows, indicating that native predictive variability underestimates reconstruction error. Linear calibration brings these curves closer to the identity over much of the range, although deviations remain in the highest-uncertainty bins. The super-resolution datasets exhibit a different pattern. On ER, the unscaled curve lies above the identity at intermediate RMV and below it at high RMV; the scaled curve retains substantial deviations, so a global linear correction does not fully capture this relationship. On MT, the unscaled curve follows the identity relatively closely at low and intermediate RMV but falls below it at higher RMV. Scaling shifts the high-uncertainty bins toward and then above the identity, while introducing overestimated uncertainty in lower bins. The relation between predictive variability and reconstruction error is thus dataset dependent.
Discussion and Limitations
BEACON replaces the observation-independent base–target assignment of GCFM with observation-conditioned starting points that are selected by their current flow-matching loss. This may ease velocity regression, but a lower selected loss alone does not establish reduced trajectory curvature or improved restoration. We therefore evaluate fidelity and perceptual quality jointly, since perceptual realism is insufficient for microscopy when reconstructed details disagree with the measured structure. Likewise, predictive variability describes variation in the learned model and requires separate validation, such as the calibration analysis above, before it can be interpreted as calibrated uncertainty.
Best-of- selection increases training computation and introduces the hyperparameters and . It also uses the target during training, whereas inference draws directly from the conditional proposal, so the selected training samples can differ in distribution from inference samples. All reported results are therefore obtained with the target-free inference procedure.
Conclusion
We introduced BEACON, which combines an observation-conditioned Gaussian proposal with best-of- training-path selection for guided flow matching, adapting the base–target assignment while preserving measured microscopy input–target pairs. On microscopy dehazing and computational super-resolution, BEACON achieves the best median perception–distortion rank across ten datasets, with the most consistent gains on dehazing.
LLM Usage Statement
We used LLM-based assistants (Claude, Anthropic; GPT models, OpenAI) for coding, writing, and typesetting. Code and experiments: writing and debugging evaluation and plotting scripts, and cross-checking reported numbers against experiment outputs. Figures: LaTeX layout of figures and floats; the microscopy images and predictions shown are unedited data and outputs of the evaluated models, and no figure content is AI-generated. Main text and supplement: drafting and editing of text, including language, structure, and LaTeX formatting, condensing the text to the page limit, consistency of notation and references, and literature search. Ideation: no research ideas; only suggestions for control experiments and for presenting results clearly within limited space. All methods, experiments, and results were designed, carried out, and verified by the authors, who take full responsibility for the content.
Training Details
Training Algorithm
Algorithm 1 BEACON Training
Require: , , candidate count , KL weight
Warm up using Eq. (1)
repeat
Draw minibatch
Draw per pair
Draw independent per pair
Construct all with Eq. (3)
Construct all interpolants
Fold candidate axis into batch axis
Evaluate in parallel
Select per pair
Freeze ; update using selected loss
Freeze ; update using selected loss
until convergence
return
Training settings
We trained BEACON separately on each dataset subset for 200 epochs with a batch size of 16, using separate Adam optimizers for the velocity and conditional noise networks with a fixed learning rate of . Training used images ( for the neuron subset). After one warm-up epoch using standard Gaussian noise, we enabled conditional noise learning with a fixed candidates per sample and minimum-loss candidate selection. The KL regularization weight was set to 0.4. Training times were sampled uniformly from 20 equally spaced points in , and the checkpoint with the lowest validation loss after warm-up was selected for evaluation. The inference setting is same as in [18, 19], where the first draw is drawn from the conditional noise model.
Compute Details
The conditional proposal network is evaluated once per degraded image, whereas the velocity model scores candidate paths per training example. Folding the candidate dimension into the batch axis lets these evaluations run in parallel, but increases training-time memory consumption and total velocity-model computation approximately linearly with . Best-of- selection is not performed at inference, which uses the same number of ODE steps and velocity-network evaluations as [18, 19] (), plus one proposal-network evaluation per input.
Training time per
Figure S2.1. Training-time overhead as a function of candidate count , on the Organoids1 Dataset Wall-clock training time (hours) for BEACON with varying numbers of candidates in the best-of- selection procedure. Training time increases gradually with , from approximately 2 hours at to 4 hours at , illustrating the computational overhead associated with exploring additional candidate couplings during training.
Inference runtime comparison of BEACON with baselines
We compare the inference efficiency of BEACON against HAZEMATCHING and other restoration baselines in Table S1. Despite introducing an additional conditional noise model, BEACON incurs negligible computational overhead during inference. The noise model contains only approximately 234K parameters and is evaluated once per image patch to generate the initial noise sample. The subsequent restoration is performed by the velocity model using the same number of integration steps as HAZEMATCHING. Consequently, BEACON achieves a comparable inference runtime (4.23 s versus 4.75 s for HAZEMATCHING), demonstrating that the benefits of learned noise initialization come at virtually no additional inference cost. The reported numbers for all the baselines are from [18].
| Model | Mean (5) [sec.] | Per Forward Pass [sec.] | Params (M) |
| RL | 13.6 | N/A | N/A |
| Elements | 3.233 | N/A | N/A |
| Lightning | 1.0 (est.) | N/A | N/A |
| UNet | 0.2944 | N/A | 13.39 |
| MIMO-UNet | 0.6358 | N/A | 6.80 |
| MPRNet | 5.4713 | N/A | 20.12 |
| RCAN | 8.6271 | N/A | 15.29 |
| ESRGAN | 1.1839 | N/A | 16.70 |
| Restormer | 4.5067 | N/A | 26.12 |
| InDI | 7.1888 | N/A | 2.44 |
| InDI | 143.3886 | 7.16943 | 2.44 |
| LVAE | 1.0118 | N/A | 5.67 |
| SIFM | 4.3120 | 0.2156 | 3.70 |
| HAZEMATCHING | 4.7498 | 0.23749 | 3.70 |
| BEACON | 4.23371 | 0.21168 | 3.942 |
Table S1. Inference runtime comparison on Organoids1 Dataset. Mean inference time over five runs, per-forward-pass runtime, and number of model parameters.
Calibration
Calibration Method
We evaluate uncertainty calibration following the procedure described in [18, 19]. For each test image, we generate posterior samples and compute the pixel-wise standard deviation and the mean prediction . Pixels are sorted by their predicted uncertainty and partitioned into equally populated bins. For each bin , we compute the root mean variance (RMV) and root mean squared error (RMSE) as
where denotes the ground truth. Using the validation set, we fit a linear calibration mapping by minimizing
The learned mapping is applied to test-set uncertainties without modifying the predictions. All calibration experiments are performed on normalized data.
Sample efficiency for calibration
Figure S3.1. Effect of posterior sample count on reconstruction fidelity and uncertainty calibration. We evaluate the influence of the number of posterior samples () across all ten microscopy datasets. Each panel reports the peak signal-to-noise ratio (PSNR, blue solid line) and the uncertainty calibration slope (, orange dashed line) as functions of . PSNR is computed from the mean of the posterior samples, while is obtained from the linear relationship between predicted uncertainty and reconstruction error. Increasing the number of samples consistently improves PSNR, with diminishing returns beyond approximately 20–30 samples. The calibration slope exhibits greater dataset-dependent variability, generally becoming more stable at larger sample counts. These results illustrate the trade-off between posterior sampling cost, reconstruction fidelity, and uncertainty estimation.
Calibration Results
Figure S3.2. Uncertainty calibration across six microscopy datasets. Comparison of the root mean variance (RMV), estimated from the pixel-wise variability of posterior samples, against the root mean squared error (RMSE) with respect to ground-truth images. Results are shown for Zebrafish, Microtubule, Neuron, CCP, F-actin, and MT-Noisy datasets. Blue curves show uncalibrated uncertainty estimates, while orange curves show estimates after applying a dataset-specific linear calibration, . The fitted scaling factor and offset are reported below each panel. The dashed black line () indicates perfect calibration, where estimated uncertainty agrees with the observed reconstruction error. Shaded regions indicate variability around the corresponding curves. Closer agreement with the diagonal indicates better uncertainty calibration.
Baselines
We follow the baseline configurations of HAZEMATCHING [18] for dehazing and RESMATCHING [19] for computational super-resolution. Both comparisons include single-output predictors and generative models that can sample multiple restorations per input. The dehazing comparison also includes classical and commercial deconvolution methods reported in [18].
Ablations
Effect of
Effect of Best-of- on Baseline Methods
Figure S5.2. Figure S5.2. Effect of Best-of- training on HAZEMATCHING/RESMATCHING baselines. We investigate whether the improvements achieved by BEACON can be attributed solely to Best-of- candidate selection by incorporating the same training strategy () into the original HazeMatching and ResMatching baselines, while retaining their standard Gaussian noise initialization. We compare the original HAZEMATCHING/RESMATCHING with Best-of- (), and BEACON () across four perception–distortion metric pairs: PSNR–LPIPS (top-left), PSNR–FID (top-right), MicroMS-SSIM–LPIPS (bottom-left), and MicroMS-SSIM–FID (bottom-right), using LPIPS (Ind) and FID (Ind). For each dataset, the empirical ideal point used to compute the NIPD score is determined from all available methods, including competing baselines and BEACON () variant. Consequently, the displayed methods retain their ranks relative to the full set of competing methods, rather than being ranked exclusively against one another (see § 4). Each box summarizes the ranks across the ten test datasets. The annotation indicates the number of contributing datasets. Methods are ordered by median rank, with mean rank used to break ties. Lower ranks indicate a more favorable perception–distortion trade-off, while narrower boxes reflect greater consistency across datasets. BEACON achieves lower median ranks than the Best-of- baselines on both PSNR-based metric pairs and matches their median ranks on both MicroMS-SSIM-based pairs, although its mean ranks are slightly higher on the latter. These results suggest that learning an observation-conditioned noise distribution provides additional benefits beyond Best-of- selection for PSNR-based perception–distortion trade-offs, while improvements are not uniform across metrics.
Effect of the Number of Inference Steps
| Steps | BEACON PSNR ↑ | BEACON LPIPS ↓ | HazeMatching PSNR ↑ | HazeMatching LPIPS ↓ |
| 2 | 37.176 | 0.1517 | 36.730 | 0.1419 |
| 3 | 37.227 | 0.1991 | 36.600 | 0.1843 |
| 4 | 37.239 | 0.2045 | 36.390 | 0.1938 |
| 5 | 37.239 | 0.2032 | 36.240 | 0.1939 |
| 10 | 37.232 | 0.1796 | 35.920 | 0.1753 |
| 15 | 37.220 | 0.1592 | 35.800 | 0.1570 |
| 30 | 37.205 | 0.1338 | 35.630 | 0.1158 |
| 50 | 37.196 | 0.1235 | 35.570 | 0.1124 |
| 80 | 37.192 | 0.1218 | 35.550 | 0.1117 |
| 100 | 37.190 | 0.1212 | 35.550 | 0.1114 |
| 150 | 37.188 | 0.1205 | 35.530 | 0.1116 |
| 200 | 37.186 | 0.1202 | 35.520 | 0.1115 |
| 250 | 37.186 | 0.1200 | 35.520 | 0.1115 |
Table S5.5. Numerical results for Organoids1. Bold: best method per step and metric. —: not available. LPIPS: individual predictions; BEACON: .
| Steps | BEACON PSNR ↑ | BEACON LPIPS ↓ | ResMatching PSNR ↑ | ResMatching LPIPS ↓ |
| 2 | 26.174 | 0.4185 | 25.771 | 0.3642 |
| 3 | 26.187 | 0.4693 | 25.767 | 0.3758 |
| 4 | 26.201 | 0.4497 | 25.747 | 0.3365 |
| 5 | 26.212 | 0.4280 | 25.729 | 0.3083 |
| 10 | 26.232 | 0.3607 | 25.684 | 0.2497 |
| 15 | 26.227 | 0.3118 | 25.664 | 0.2290 |
| 20 | 26.217 | 0.2735 | 25.647 | 0.2182 |
| 30 | 26.201 | 0.2274 | 25.624 | 0.2093 |
| 50 | 26.184 | 0.2285 | 25.603 | 0.2425 |
| 80 | 26.173 | 0.2402 | 25.589 | 0.2564 |
| 100 | 26.169 | 0.2430 | 25.584 | 0.2597 |
| 150 | 26.163 | 0.2463 | 25.576 | 0.2635 |
| 200 | 26.160 | 0.2478 | 25.573 | 0.2653 |
| 250 | 26.159 | 0.2486 | 25.570 | 0.2663 |
Table S5.6. Numerical results for ER. Bold: best method per step and metric. —: not available. LPIPS: individual predictions; BEACON: .
The number of inference steps provides a user-adjustable control over the perception–distortion operating point without changing the trained model. With uniform Euler integration over , reducing increases the step size and reduces inference cost, whereas increasing yields finer integration at greater computational cost. As in HAZEMATCHING and RESMATCHING [18, 19], this allows users to explore settings that favor perceptual quality or reconstruction fidelity rather than relying solely on the default .
The comparison, shown in Figure S5.5, considers two datasets, one for dehazing (Organoids1) and one for super-resolution (ER), pairing BEACON () with HAZEMATCHING and RESMATCHING, respectively. PSNR and LPIPS characterize the distortion and perceptual quality at each value of . The preferred setting depends on the dataset and the desired balance between these criteria; increasing need not improve both metrics simultaneously.
Figure S5.5. Effect of inference timesteps on reconstruction fidelity and perceptual quality. We evaluate the influence of the number of inference timesteps on BEACON () and the corresponding HAZEMATCHING [18] and RESMATCHING [19] baselines using Organoids1 (dehazing) and ER (computational super-resolution). Each panel reports PSNR (solid lines) and LPIPS (dashed lines) as functions of the number of inference timesteps. BEACON consistently maintains higher PSNR across both datasets, exhibiting substantially less degradation as the number of timesteps increases. While LPIPS varies with the integration step count, BEACON achieves competitive perceptual quality, particularly at larger numbers of timesteps. These results demonstrate that BEACON is less sensitive to the choice of inference timesteps, maintaining a favorable perception–distortion trade-off over a wide range of integration steps.
Effect of Posterior Sample Averaging
We investigate how the number of posterior samples affects reconstruction fidelity by computing the PSNR of their pixel-wise mean. As shown in Figure S5.6, increasing the number of averaged samples improves PSNR for both BEACON and the corresponding HAZEMATCHING and RESMATCHING baselines, with diminishing returns beyond approximately 20–30 samples. Interestingly, although BEACON exhibits lower single-sample PSNR, it surpasses both baselines when averaging as few as five predictions and consistently maintains higher fidelity thereafter. This suggests that BEACON’s individual sample predictions exhibit errors that are more effectively reduced through averaging, resulting in a more accurate posterior-mean estimate.
Figure S5.6. Effect of posterior sample averaging on reconstruction fidelity. We evaluate the influence of the number of posterior predictions averaged () on BEACON () and the corresponding HAZEMATCHING [18] and RESMATCHING [19] baselines using Organoids1 (dehazing) and ER (computational super-resolution). Each panel reports the PSNR computed from the pixel-wise mean of posterior predictions. Increasing the number of averaged predictions improves PSNR for all methods, with diminishing returns beyond approximately 20–30 samples. Although BEACON surpasses the corresponding baselines with as few as five averaged predictions and maintains a consistent advantage as increases. These results demonstrate that BEACON benefits more strongly from posterior averaging, achieving higher reconstruction fidelity with relatively few posterior samples.
Dataset
We evaluate on five dehazing datasets from HAZEMATCHING and five RESMATCHING subsets for computational super-resolution. The latter comprise the four subsets evaluated in RESMATCHING and the microtubule subset without added noise (MT), available through the official RESMATCHING repository. Table S2 summarizes the image splits and training patches.
| Dataset | Train | Val. | Test | Train size | Count | Size |
| Dehazing | ||||||
| Zebrafish | 15 | 3 | 3 | 3,000 | ||
| Organoids1 | 15 | 2 | 3 | 3,000 | ||
| Organoids2 | 15 | 2 | 3 | 3,000 | ||
| Microtubule3 | 52 | 5 | 5 | 3,016 | ||
| Neuron | 5,800 | 100 | 100 | 5,800 | ||
| Computational super-resolution (BioSR) | ||||||
| CCP | 39 | 5 | 10 | 3,120 | ||
| ER | 53 | 5 | 10 | 4,240 | ||
| F-actin | 35 | 5 | 10 | 2,800 | ||
| MT-Noisy | 40 | 5 | 10 | 3,200 | ||
| MT | 40 | 5 | 10 | 3,200 |
Table S2. Dataset splits and training patch counts for dehazing and computational super-resolution. Train, Val., and Test count paired images before patch extraction. Sizes are in pixels.
The Microtubule dehazing validation and test images are pixels. For Neuron, each training image is used directly as a patch.
Results
Perception–Distortion Plots
Figure S7.1. Perception–distortion trade-off on Zebrafish and Organoids1. We compare BEACON () against competing restoration methods on (A) Zebrafish and (B) Organoids1. For each dataset, we show PSNR vs. LPIPS (top-left), PSNR vs. FID (top-right), MicroMS-SSIM vs. LPIPS (bottom-left), and MicroMS-SSIM vs. FID (bottom-right). Higher PSNR and MicroMS-SSIM indicate better fidelity, while lower LPIPS and FID indicate better perceptual quality. The empirical ideal point, combining the best observed distortion and perceptual scores, is indicated by , while colored markers denote individual methods. Axes are oriented such that the bottom-left corner represents the most favorable trade-off. Corresponding numerical results along with NIPD scores (best one in bold) are provided on the right.
Figure S7.2. Perception–distortion trade-off on Organoids2 and Microtubule. We compare BEACON () against competing restoration methods on (A) Organoids2 and (B) Microtubule (dehazing; distinct from the super-resolution MT dataset). For each dataset, four metric combinations are shown: PSNR vs. LPIPS, PSNR vs. FID, MicroMS-SSIM vs. LPIPS, and MicroMS-SSIM vs. FID. Higher PSNR and MicroMS-SSIM indicate better fidelity, while lower LPIPS and FID indicate better perceptual quality. The empirical ideal point, combining the best observed distortion and perceptual scores, is indicated by ◉, while colored markers denote individual methods. Axes are oriented such that the bottom-left corner represents the most favorable trade-off. Corresponding numerical results along with NIPD scores (best one in bold) are provided on the right..
Figure S7.3. Perception–distortion trade-off on Neurons and CCP. We compare BEACON () against competing restoration methods on (A) Neurons and (B) Clathrin-Coated Pits (CCP). For each dataset, we show PSNR vs. LPIPS (top-left), PSNR vs. FID (top-right), MicroMS-SSIM vs. LPIPS (bottom-left), and MicroMS-SSIM vs. FID (bottom-right). Higher PSNR and MicroMS-SSIM indicate better fidelity, while lower LPIPS and FID indicate better perceptual quality. The empirical ideal point, combining the best observed distortion and perceptual scores, is indicated by ⊙, while colored markers denote individual methods. Axes are oriented such that the bottom-left corner represents the most favorable trade-off. Corresponding numerical results along with NIPD scores (best one in bold) are provided on the right.
Figure S7.4. Perception–distortion trade-off on ER and F-actin. We compare BEACON () against competing restoration methods on (A) Endoplasmic Reticulum (ER) and (B) F-actin. For each dataset, we show PSNR vs. LPIPS (top-left), PSNR vs. FID (top-right), MicroMS-SSIM vs. LPIPS (bottom-left), and MicroMS-SSIM vs. FID (bottom-right). Higher PSNR and MicroMS-SSIM indicate better fidelity, while lower LPIPS and FID indicate better perceptual quality. The empirical ideal point, combining the best observed distortion and perceptual scores, is indicated by ◉, while colored markers denote individual methods. Axes are oriented such that the bottom-left corner represents the most favorable trade-off. Corresponding numerical results along with NIPD scores (best one in bold) are provided on the right.
Figure S7. Perception–distortion trade-off on MT and MT-Noisy. We compare BEACON () against competing restoration methods on (A) Microtubules (MT) and (B) Noisy Microtubules (MT-Noisy). For each dataset, we show PSNR vs. LPIPS (top-left), PSNR vs. FID (top-right), MicroMS-SSIM vs. LPIPS (bottom-left), and MicroMS-SSIM vs. FID (bottom-right). Higher PSNR and MicroMS-SSIM indicate better fidelity, while lower LPIPS and FID indicate better perceptual quality. The empirical ideal point, combining the best observed distortion and perceptual scores, is indicated by , while colored markers denote individual methods. Axes are oriented such that the bottom-left corner represents the most favorable trade-off. Corresponding numerical results along with NIPD scores (best one in bold) are provided on the right.
Qualitative Results

Figure S8.1. Additional qualitative results. We show representative restoration results for two datasets: Zebrafish (upper panels) and Organoids[1] (lower panels). For each dataset, we show (a) the full degraded input with a selected crop (yellow box), (b) the degraded crop, (c) the corresponding ground truth, (d–g) predictions from four competing methods, and (h) BEACON (). For generative posterior models, diagonally split images show the MMSE estimate (upper-left) and a representative posterior sample (lower-right), with MMSE PSNR and sample LPIPS reported, respectively. For point-predicting methods, PSNR and LPIPS are reported directly.

Figure S8.2. Additional qualitative results. We show representative restoration results for two datasets: Organoids2 (upper panels) and Microtubule (lower panels). For each dataset, we show (a) the full degraded input with a selected crop (yellow box), (b) the degraded crop, (c) the corresponding ground truth, (d–g) predictions from four competing methods, and (h) BEACON (). For generative posterior models, diagonally split images show the MMSE estimate (upper-left) and a representative posterior sample (lower-right), with MMSE PSNR and sample LPIPS reported, respectively. For point-predicting methods, PSNR and LPIPS are reported directly.

Figure S8.3. Additional qualitative results. We show representative restoration results for two datasets: Neuron (upper panels) and CCP (lower panels). For each dataset, we show (a) the full degraded input with a selected crop (yellow box), (b) the degraded crop, (c) the corresponding ground truth, (d–g) predictions from four competing methods, and (h) BEACON (). For generative posterior models, diagonally split images show the MMSE estimate (upper-left) and a representative posterior sample (lower-right), with MMSE PSNR and sample LPIPS reported, respectively. For point-predicting methods, PSNR and LPIPS are reported directly.

Figure S8.4. Additional qualitative results. We show representative restoration results for two datasets: ER (upper panels) and F-actin (lower panels). For each dataset, we show (a) the full degraded input with a selected crop (yellow box), (b) the degraded crop, (c) the corresponding ground truth, (d–g) predictions from four competing methods, and (h) BEACON (). For generative posterior models, diagonally split images show the MMSE estimate (upper-left) and a representative posterior sample (lower-right), with MMSE PSNR and sample LPIPS reported, respectively. For point-predicting methods, PSNR and LPIPS are reported directly.

Figure S8.5. Additional qualitative results. We show representative restoration results for two datasets: MT (super-resolution) (upper panels) and MT Noisy (lower panels). For each dataset, we show (a) the full degraded input with a selected crop (yellow box), (b) the degraded crop, (c) the corresponding ground truth, (d–g) predictions from four competing methods, and (h) BEACON (). For generative posterior models, diagonally split images show the MMSE estimate (upper-left) and a representative posterior sample (lower-right), with MMSE PSNR and sample LPIPS reported, respectively. For point-predicting methods, PSNR and LPIPS are reported directly.
References
- [1]Michael Samuel Albergo, Mark Goldstein, Nicholas Matthew Boffi, Rajesh Ranganath, and Eric Vanden-Eijnden. Stochastic interpolants with data-dependent couplings. In Proceedings of the 41st International Conference on Machine Learning, pages 921–937. PMLR, 2024. 2, 3arxiv.org/abs/2310.03725
- [2]Ashesh Ashesh, Federico Carrara, Igor Zubarev, Vera Galinova, Melisande Croft, Melissa Pezzotti, Daozheng Gong, Francesca Casagrande, Elisa Colombo, Stefania Giussani, Elena Restelli, Eugenia Cammarota, Juan Manuel Battagliotti, Nikolai Klena, Moises Di Sante, Gaia Pigino, Elena Taverna, Oliver Harschnitz, Nicola Maghelli, Norbert Scherer, Damian Edward Dalle Nogare, Joran Deschamps, Francesco Pasqualini, and Florian Jug. Microsplit: Semantic unmixing of fluorescent microscopy data. bioRxiv, 2025. 5, 6DOI
- [3]Yochai Blau and Tomer Michaeli. The perception-distortion tradeoff. In 2018 IEEE Conference on Computer Vision and Pattern Recognition, CVPR 2018, Salt Lake City, UT, USA, June 18-22, 2018, pages 6228–6237. Computer Vision Foundation / IEEE Computer Society, 2018. 1DOI
- [4]Federico Carrara, Aman Kukde, Melisande Croft, Joran Deschamps, and Florian Jug. SWITi: Quantifying and reducing tiling artifacts with sliding window inner tiling. In European Conference on Computer Vision (ECCV), 2026. 6arxiv.org/abs/2607.18990
- [5]Sung-Jin Cho, Seo-Won Ji, Jun-Pyo Hong, Seung-Won Jung, and Sung-Jae Ko. Rethinking coarse-to-fine approach in single image deblurring. In 2021 IEEE/CVF International Conference on Computer Vision (ICCV), pages 4621–4630, 2021. 2arxiv.org/abs/2108.05054
- [6]Prafulla Dhariwal and Alex Nichol. Diffusion models beat gans on image synthesis, 2021. 5
- [7]Alexi Gladstone, Heng Ji, and Yilun Du. Explorative modeling: Unlocking a third pretraining axis and end-to-end generation, 2026. 2, 3arxiv.org/abs/2607.27372
- [8]Alexander Krull, Tomas Vicar, and Florian Jug. Probabilistic noise2void: Unsupervised content-aware denoising, 2019. 2DOI
- [9]Sangyun Lee, Beomsu Kim, and Jong Chul Ye. Minimizing trajectory curvature of ODE-based generative models. In Proceedings of the 40th International Conference on Machine Learning, pages 18957–18973. PMLR, 2023. 1, 2, 3arxiv.org/abs/2301.12003
- [10]Sangyun Lee, Beomsu Kim, and Jong Chul Ye. Minimizing trajectory curvature of ode-based generative models. arXiv preprint arXiv:2301.12003, 2023. 2arxiv.org/abs/2301.12003
- [11]Ke Li and Jitendra Malik. Implicit maximum likelihood estimation, 2018. 2, 3arxiv.org/abs/1809.09087
- [12]Yaron Lipman, Ricky T. Q. Chen, Heli Ben-Hamu, Maximilian Nickel, and Matthew Le. Flow matching for generative modeling. In The Eleventh International Conference on Learning Representations, 2023. 3arxiv.org/abs/2210.02747
- [13]Guy Ohayon, Tomer Michaeli, and Michael Elad. Posterior-mean rectified flow: Towards minimum MSE photo-realistic image restoration. In The Thirteenth International Conference on Learning Representations, 2025. 2arxiv.org/abs/2410.00418
- [14]Adam Paszke, Sam Gross, Soumith Chintala, Gregory Chanan, Edward Yang, Zachary DeVito, Zeming Lin, Alban Desmaison, Luca Antiga, and Adam Lerer. Automatic differentiation in pytorch. In NIPS-W, 2017. 5
- [15]Wenxuan Peng, Richard Zhang, Haitian Zheng, Jaskirat Singh, Tsai-Shien Chen, Eli Shechtman, Bharath Hariharan, Hadar Avraham-Elor, and Zongze Wu. Expanding the quality–coverage frontier with competitive flow matching, 2026. 2arxiv.org/abs/2611.07055
- [16]Aram-Alexandre Pooladian, Heli Ben-Hamu, Carles Domingo-Enrich, Brandon Amos, Yaron Lipman, and Ricky T. Q. Chen. Multisample flow matching: Straightening flows with minibatch couplings. In International Conference on Machine Learning, ICML 2023, 23-29 July 2023, Honolulu, Hawaii, USA, pages 28100–28127. PMLR, 2023. 2, 3arxiv.org/abs/2304.14772
- [17]Mangal Prakash, Mauricio Delbracio, Peyman Milanfar, and Florian Jug. Interpretable unsupervised diversity denoising and artefact removal. In International Conference on Learning Representations, 2022. 2arxiv.org/abs/2104.01374
- [18]Anirban Ray, Ashesh Ashesh, and Florian Jug. Hazematching: Dehazing light microscopy images with guided conditional flow matching. In Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (Findings), 2026. 1, 2, 3, 4, 5, 8, 11, 12, 13, 14, 18, 19arxiv.org/abs/2506.22397
- [19]Anirban Ray, Vera Grascoso, and Florian Jug. Resmatching: Noise-resilient computational super-resolution via guided conditional flow matching. 2026 IEEE 23rd International Symposium on Biomedical Imaging (ISBI), 2026. 1, 2, 3, 4, 5, 8, 11, 13, 14, 18, 19
- [20]Olaf Ronneberger, Philipp Fischer, and Thomas Brox. U-net: Convolutional networks for biomedical image segmentation. In Medical Image Computing and Computer-Assisted Intervention - MICCAI 2015 - 18th International Conference Munich, Germany, October 5 - 9, 2015, Proceedings, Part III, pages 234–241. Springer, 2015.arxiv.org/abs/1505.04597
- [21]Hari Shroff, Ilaria Testa, Florian Jug, and Suliana Manley. Live-cell imaging powered by computation. Nature Reviews Molecular Cell Biology, 25, 2024.arxiv.org/abs/2401.01438
- [22]Casper Kaae Sønderby, Tapani Raiko, Lars Maaløe, Søren Kaae Sønderby, and Ole Winther. Ladder variational autoencoders. In Advances in Neural Information Processing Systems 29: Annual Conference on Neural Information Processing Systems 2016, December 5-10, 2016, Barcelona, Spain, pages 3738–3746, 2016.arxiv.org/abs/1602.02282
- [23]Alexander Y. Tong. Torchcfm: A conditional flow matching library, 2024. Accessed: 2025-05-04.
- [24]Martin Weigert, Uwe Schmidt, Tobias Boothe, Andreas Müller, Alexandr Dibrov, Akanksha Jain, Benjamin Wilhelm, Deborah Schmidt, Coleman Broaddus, Siân Culley, Mauricio Rocha-Martins, Fabián Segovia-Miranda, Caren Norden, Ricardo Henriques, Marino Zerial, Michele Solimena, Jochen Rink, Pavel Tomancak, Loic Royer, Florian Jug, and Eugene W. Myers. Content-aware image restoration: Pushing the limits of fluorescence microscopy. bioRxiv, 2018.DOI
- [25]Syed Waqas Zamir, Aditya Arora, Salman Khan, Munawar Hayat, Fahad Shahbaz Khan, Ming-Hsuan Yang, and Ling Shao. Multi-stage progressive image restoration. In 2021 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), pages 14816–14826, 2021.arxiv.org/abs/2102.02808
- [26]Yulun Zhang, Kunpeng Li, Kai Li, Lichen Wang, Bineng Zhong, and Yun Fu. Image super-resolution using very deep residual channel attention networks. In Proceedings of the European Conference on Computer Vision (ECCV), pages 286–301, 2018.arxiv.org/abs/1807.02758