betaFeedback

WorksPhysics and Astronomy

A photonic-integrated optomechanical mid-infrared detector

Abstract

Tracking the resonance frequency of a mechanical oscillator is the basis of atomic force microscopy, mass sensing and thermometry. Nanomechanical thermal detectors exploit this principle to sense absorbed radiation, most effectively with tensile-stressed resonators, whose tension converts thermal expansion into a large frequency shift and dilutes dissipation. Approaching their fundamental sensitivity limit, however, has required free-space or fibre-coupled interferometers, hindering compact deployment and scaling to arrays. Here we remove this bottleneck by monolithically integrating a high-Q nanomechanical resonator with a silicon nitride photonic integrated circuit. A tensile-stressed silicon nitride trampoline with an impedance-matched platinum absorber is dispersively coupled to a photonic integrated microresonator beneath it. At room temperature and with microwatt-level optical power, the detector reaches a noise-equivalent power of 3.4 pW/Hz\sqrt{\rm Hz} for broadband thermal radiation (3-12 μμm), referred to incident power. Referred to absorbed power, this is within a factor of 1.5 of its fundamental thermal fluctuation limit. Using our detector in a state-of-the-art commercial Fourier-transform infrared spectrometer, we resolve the vibrational fingerprint of a polymer film across 2-20 μμm and reach the precision of the built-in pyroelectric detector with about an order of magnitude lower incident power. This architecture opens a route to multiplexed optomechanical focal-plane arrays.

Mid-infrared (mid-IR) detection is central to science and engineering, from environmental monitoring [1] to the study of planet formation [2]. While scientific applications push for ever higher sensitivity, emerging ones such as autonomous navigation [3] and smart cities [4] require detectors that combine high performance with low size, weight, power and cost. Narrow-bandgap photon detectors typically meet the performance requirement only with cryogenic cooling, as their dark current rises exponentially with temperature [5, 6]. Thermal detectors, which sense the heat generated by absorbed radiation through a temperature-dependent property, range from cryogenic bolometers, which revealed the near-perfect black-body spectrum of the cosmic microwave background [7], to uncooled microbolometer arrays. The latter operate at room temperature and are volume-manufactured on CMOS readout circuits [8], but they remain at least several times above the fundamental limit set by thermodynamic temperature fluctuations [6, 9, 10].

Since Langley’s bolometer of 1880 [11], most thermal detectors have relied on a suspended, low-heat-capacity absorber linked to its surroundings by thin supports of low thermal conductance [12], with its temperature read by an electrical thermometer. It is this thermometer that limits uncooled microbolometers, in two ways. First, the bias current needed to lift the signal above the Johnson noise of the readout, carried through supports that must double as electrical leads, also heats the element it measures. Second, the few, thermally activated carriers that give semiconducting films their high temperature sensitivity make their resistance flicker, with a 1/f1/f noise that no bias can remove [9, 13]. Alternative thermometers that avoid resistive readout have therefore been explored, including the dispersion of exciton polaritons [14], magnetization switching rates [15], and the resonance frequency of optical [16, 17] and mechanical resonators [18].

Among these, tensile-stressed nanomechanical resonators are particularly suited, as their low-frequency modes combine enhanced temperature sensitivity [19] with quality factors far exceeding material limits [20], which has led to mechanical thermal detectors (MTDs) based on silicon nitride [21, 22, 23] and graphene [24]. Because the signal is carried by a resonance frequency rather than by a resistance at DC, even electrically transduced MTDs reach noise-equivalent powers (NEPs) comparable to those of uncooled microbolometers [25]. Electrical transduction, however, still requires conductive layers or electrodes at the resonator, and its imprecision is set by the amplification chain [26, 27]. Optical readout removes both: it requires no contact with the resonator and can approach the quantum limits of displacement measurement [28]. Optically read MTDs have accordingly approached their fundamental limit [29], with frequency stability limited by thermodynamic temperature fluctuations [30, 31]. These devices, however, rely on laboratory-scale free-space or fibre-based interferometers [32], requiring per-device alignment that is at odds with compact and scalable sensing architectures.

Photonic integrated circuits (PICs) are a natural route to integrating such readout. They already serve as the optical interface to trapped ions for quantum computing [33, 34], atomic vapours for optical clocks [35] and suspended membranes for ultrasound detection [36]. With propagation losses now below 1 dB/m1\,\mathrm{dB}/\mathrm{m} [37], ultra-low-loss Si3N4\mathrm{Si}_3\mathrm{N}_4 PICs also host chip-scale frequency combs [38], erbium-doped amplifiers [39] and low-noise lasers [40, 41], the building blocks of a self-contained, multiplexed optical readout. For nanomechanical resonators, chip-scale near-field optical readout is well established, both with resonators positioned next to stand-alone microcavities [42] and with resonators co-fabricated with the optics on dedicated chips [28, 43, 44, 45]. In each case, however, the photonic and mechanical elements are designed and fabricated together for the purpose. A modular architecture, in which the mechanical layer is added to an existing PIC platform, inheriting its ecosystem while remaining free to be optimized on its own, has not yet been demonstrated for high-QQ, tensile-stressed nanomechanical resonators.

Here we demonstrate such an architecture for mid-IR detection. A high-QQ, tensile-stressed SixNy\mathrm{Si}_x\mathrm{N}_y trampoline resonator, functionalized with an impedance-matched platinum absorber, is surface-micromachined with standard MEMS processes above a foundry-compatible Si3N4\mathrm{Si}_3\mathrm{N}_4 PIC, and a microring resonator of the circuit, directly beneath the trampoline, reads out its motion through near-field coupling. At microwatt-level on-chip power, this cavity-enhanced readout leaves the detector limited, at the frequencies of best sensitivity, by intrinsic fluctuations of the resonance frequency, which also follow a 1/f1/f spectrum [46]. With a pixel-scale absorber and a millisecond response, the detector reaches a room-temperature minimum NEP of 3.4 pW/Hz3.4\,\mathrm{pW}/\sqrt{\mathrm{Hz}} referred to incident power and, referred to absorbed power, lies within a factor of 1.51.5 of its fundamental thermal-fluctuation limit. Deployed at an auxiliary port of a commercial Fourier-transform infrared (FTIR) spectrometer, alongside its built-in pyroelectric detector, it records broadband mid-IR transmission spectra in quantitative agreement with those of the reference instrument.

Figure 1. Monolithic integration of a mechanical thermal detector (MTD) with a photonic integrated circuit. a, Schematic of the cavity-optomechanical MTD (OMTD) concept, whereby cavity-enhanced optical detection of mechanical motion is used to determine mechanical frequency changes, ΔΩm\Delta\Omega_{\mathrm{m}}, proportional to the incident mid-infrared radiation, PMIRP_{\mathrm{MIR}}. b, Exploded view of the device, which consists of a platinum-coated trampoline nanomechanical resonator suspended hundreds of nanometres above a Si3_3N4_4 photonic ring microresonator coupled to a bus waveguide. Bottom: cross-section along the vertical plane shown. c, Optical microscope image of a few OMTDs suspended above respective ring resonators. The bus waveguides are visible through the air channels opened above them. d, False-coloured SEM micrograph of a single OMTD. Uncoloured: SiO2_2 cladding with Si3_3N4_4 filler pattern, navy blue: Si3_3N4_4 PICs, red: Six_xNy_y nanomechanical resonator layer, light blue: Pt disk absorber, e: Finite-element-method (FEM) simulation of the frequency-pull parameter GG of the ring resonance as a function of the gap dd. The inset shows the cross-section of the electric-field magnitude, ∣E∣\lvert E\rvert, of the mode and the electric field lines. f, Measured and fitted normalized transmission of the TM00_{00} resonance used in the experiments, with η=κe/κ\eta=\kappa_{\mathrm{e}}/\kappa. The dashed line marks the maximum-slope detuning used in g and h. g, Calibrated displacement noise power spectral density (PSD) for the fundamental mechanical mode of the trampoline as a function of the detection power PdetP_{\mathrm{det}} sent to the chip. The inset shows the mode profile. h, Same as g for two different incident mid-IR powers, PMIRP_{\mathrm{MIR}}. i, Measured dependence of the frequency shift on the incident mid-IR power and linear fit, whose slope gives the fractional responsivity to the total incident power, R0inc,tot=(ΔΩm/Ωm,0)/PMIR\mathcal{R}_{0}^{\mathrm{inc,tot}}=(\Delta\Omega_{\mathrm{m}}/\Omega_{\mathrm{m},0})/P_{\mathrm{MIR}}.

Si3_3N4_4 PIC-based optomechanical readout

Figure 1(a) illustrates our cavity-optomechanical approach to MTDs with the canonical representation of cavity optomechanics 1: a laser drives an optical cavity whose end mirror is suspended on a spring, and the dispersive coupling between the intracavity field and the mirror motion allows the displacement of the mirror to be read out. Upon absorption of incident radiation, the resonator heats up, altering its spring constant and thereby shifting its resonance frequency by ΔΩm\Delta\Omega_{\mathrm{m}} 2. Figure 1(b) shows our implementation in devices viewed in plan and a cross-section. The bottom layers form the SiO2_2-clad Si3_3N4_4 PIC used for readout, a ring microresonator side-coupled to a bus waveguide. Above them, a trampoline resonator made from silicon-rich Six_xNy_y with moderate tensile stress (about 170 MPa, versus about 1 GPa for stoichiometric Si3_3N4_4), which enhances the photothermal frequency shift arising from thermal expansion 3, is anchored through polysilicon (poly-Si) supports

and suspended hundreds of nanometres above the thin cladding covering the ring. A platinum (Pt) disk on its central pad serves as an impedance-matched mid-IR absorber 4 while adding little heat capacity and mechanical dissipation 5.

The Si3_3N4_4 PICs are defined by the photonic damascene process 6 and buried under a thin SiO2_2 cladding and a sacrificial poly-Si layer that nominally sets the gap dd between the trampoline and the cladding. The Pt-coated Six_xNy_y resonators are patterned above this stack and released by XeF2_2 etching of the poly-Si (Methods). Figures 1(c) and (d) show a microscope image of several optomechanical thermal detectors (OMTDs) on a chip and a false-colour scanning electron micrograph of one of them. Above the bus waveguide, the high-refractive-index poly-Si is removed along an air channel for efficient guiding. The chip is fibre-packaged and operated in vacuum, and, unless stated otherwise, all results reported here are for one of its OMTDs (Methods).

The evanescent field of the photonic microresonator modes, overlapping with the trampoline (inset of Fig. 1(e)), gives rise to near-field dispersive optomechanical coupling via the gradient optical force 7, with a frequency-pull parameter G=∣∂ω0/∂d∣G=|\partial\omega_0/\partial d| (with ω0\omega_0 the optical resonance frequency) that decays exponentially with dd (Fig. 1(e)). We use the fundamental transverse-magnetic (TM00\mathrm{TM}_{00}) mode family, which provides about 50% more coupling than the fundamental transverse-electric family (Supplementary § 4.1.3), and drive a single resonance at λ0=1555.24\lambda_0=1555.24 nm with a continuous-wave laser (κ/2π=1.16\kappa/2\pi=1.16 GHz, η=κe/κ=0.65\eta=\kappa_\mathrm{e}/\kappa=0.65, Fig. 1(f) and Supplementary Section 1.2). Direct detection of the transmitted intensity on the cavity slope (dashed line in Fig. 1(f)) resolves the thermomechanical motion of the fundamental out-of-plane flexural mode (inset of Fig. 1(g)) with microwatt-level on-chip power, as shown in Fig. 1(g) for varying optical power sent to the chip, PdetP_\mathrm{det}. The mode has an unperturbed frequency Ωm,0/2π=549.6\Omega_\mathrm{m,0}/2\pi=549.6 kHz and a linewidth Γm/2π=2.80±0.09\Gamma_\mathrm{m}/2\pi=2.80\pm0.09 Hz, corresponding to Q≈2×105Q\approx2\times10^5, and its calibrated vacuum optomechanical coupling rate, g0/2π=71±5g_0/2\pi=71\pm5 Hz, is within 20% of the value from finite-element-method (FEM) simulations (Methods and Supplementary § 4.1.3–§ 4.1.5).

Illuminating the QMTD with a focused mid-IR thermal source (Methods) shifts its thermomechanical spectrum (Fig. 1(h)) linearly with the incident power, by up to nearly a thousand mechanical linewidths (Fig. 1(i)).

Frequency tracking and noise budget

The shifts in Figs. 1(h,i) are inferred from thermomechanical spectra averaged over long times. Operating the detector instead requires tracking the resonance frequency continuously. The most established approach drives the resonator coherently and extracts its frequency from the phase of the demodulated displacement signal [52]. We implement it with the scheme of Figure 2(a), in which a phase-locked loop (PLL) keeps an off-chip piezoelectric drive (PZT) on resonance and the frequency estimate Ω~m\tilde{\Omega}_m is obtained from a separate, out-of-loop demodulator (Methods). In this scheme, fluctuations of Ω~m\tilde{\Omega}_m combine real fluctuations of Ωm\Omega_m, which can have several physical origins, with two measurement artefacts [27, 53, 54, 55]: the thermomechanical and detection noise imprinted on the measured oscillation phase by the Brownian motion of the resonator and by the finite displacement imprecision. Their double-sided power spectral density (PSD) reads (Supplementary § 4.2.1)

Figure 2. Intrinsic, detection and photothermal contributions to the frequency noise. a, Schematic of the setup used for measuring the frequency fmf_\mathrm{m} of the fundamental mode of the trampoline resonator over time. ECDL: external-cavity diode laser, PZT: piezoelectric transducer, PLL: phase-locked loop. Demod 2 is part of the PLL, while fm(t)f_\mathrm{m}(t) is extracted from the quadratures X(t)X(t), Y(t)Y(t) of the out-of-loop Demod 1. b, Representative time traces of fmf_\mathrm{m} for two driving voltages, VpztV_\mathrm{pzt}. c, Power spectral density (PSD) of the frequency fluctuations for varying VpztV_\mathrm{pzt} at a fixed laser cavity detuning, Δ\Delta, and off-chip optical power, PdetP_\mathrm{det}. The solid lines represent Eq. (1) and the dashed line is a 1/ω1/\omega guide to the eye. d, Detected oscillation amplitude, Xosc=X(t)2+Y(t)2X_\mathrm{osc}=\sqrt{X(t)^2+Y(t)^2}, calibrated assuming linear transduction, as a function of VpztV_\mathrm{pzt}. The dashed line represents a linear fit to the data at Vpzt≲5V_\mathrm{pzt}\lesssim5 mV. Schematics: motion-induced modulation of the cavity transmission in the linear (GXosc≪κ/2GX_\mathrm{osc}\ll\kappa/2) and nonlinear (GXosc≳κ/2GX_\mathrm{osc}\gtrsim\kappa/2) transduction regimes. e, Inverse of the detection noise coefficient (DD from a fit of the PSD at large sideband frequencies ω\omega with Dω2D\omega^2) as a function of Δ\Delta (grey dots, left axis) and theoretical maximum of the detected optical power in the first sideband, PN=1P_{\mathrm{N}=1}, assuming a perfect Lorentzian cavity response (blue solid line, right axis). The detuning Δ∗\Delta_* of subsequent measurements is highlighted with a dash-dotted line. f, PSD of the frequency fluctuations measured at varying PdetP_\mathrm{det}. The shaded area marks the range ∣ω∣/2π<30|\omega|/2\pi<30 Hz and the dash-dotted line is the thermal cutoff ωth/2π\omega_\mathrm{th}/2\pi. g, Band-limited (shaded area in f) variance of the measured frequency, ⟨δΩ~m2⟩∣ω∣/2π<30 Hz\langle\delta\widetilde{\Omega}_m^2\rangle_{|\omega|/2\pi<30\ \mathrm{Hz}} (grey, left axis), and detection noise coefficient DD (blue, right axis) as a function of PdetP_\mathrm{det}. Solid lines are fits to s0+s2Pdet2s_0+s_2P_\mathrm{det}^2 and d2/Pdet2+d1/Pdetd_2/P_\mathrm{det}^2+d_1/P_\mathrm{det}, respectively, and broken lines their individual contributions.

SΩ~mΩ~m(ω)=SΩmΩm(ω)+Xth2Xosc2Γm2+(ω2+Γm24)SxximpXosc2.(1)S_{\tilde{\Omega}_m\tilde{\Omega}_m}(\omega)=S_{\Omega_m\Omega_m}(\omega)+\frac{X_{\mathrm{th}}^2}{X_{\mathrm{osc}}^2}\frac{\Gamma_m}{2}+\left(\omega^2+\frac{\Gamma_m^2}{4}\right)\frac{S_{xx}^{\mathrm{imp}}}{X_{\mathrm{osc}}^2}. \tag*{(1)}

References

  1. [1]Bereyhi, M. J. et al. Perimeter Modes of Nanomechanical Resonators Exhibit Quality Factors Exceeding 10⁹ at Room Temperature. Physical Review X 12, 021036 (2022).
  2. [2]Johnson, S. G. et al. Perturbation theory for Maxwell’s equations with shifting material boundaries. Physical Review E 65, 066611 (2002).pubmed.ncbi.nlm.nih.gov/12188855
  3. [3]Javid, U. A., Rogers, S. D., Graf, A. & Lin, Q. Cavity Optomechanical Sensing in the Nonlinear Saturation Limit. Laser & Photonics Reviews 15, 2100166 (2021).arxiv.org/abs/2007.04279
  4. [4]Lifshitz, R. & Cross, M. C. Nonlinear Dynamics of Nanomechanical and Micromechanical Resonators. In Reviews of Nonlinear Dynamics and Complexity, 1–52 (John Wiley & Sons, Ltd, 2008).DOI
  5. [5]Schmid, S., Villanueva, L. G. & Roukes, M. L. Fundamentals of Nanomechanical Resonators (Springer International Publishing, Cham, 2023).
  6. [6]Bao, M., Yang, H., Yin, H. & Sun, Y. Energy transfer model for squeeze-film air damping in low vacuum. Journal of Micromechanics and Microengineering 12, 341 (2002).DOI
  7. [7]Bešić, H., Demir, A., Steurer, J., Luhmann, N. & Schmid, S. Schemes for Tracking Resonance Frequency for Micro- and Nanomechanical Resonators. Physical Review Applied 20, 024023 (2023).
  8. [8]Kanellopulos, K. et al. Comparative analysis of nanomechanical resonators: sensitivity, response time, and practical considerations in photothermal sensing. Microsystems & Nanoengineering 11, 28 (2025).DOI
  9. [9]Martini, P. et al. Uncooled thermal infrared detection near the fundamental limit using a silicon nitride nanomechanical resonator with a broadband absorber. Communications Physics 8, 166 (2025).DOI
  10. [10]Brown, S. C., Shaniv, R., Zhang, R., Reetz, C. & Regal, C. A. High-Stability Mechanical Frequency Sensing beyond the Linear Regime. Nano Letters 26, 2052–2058 (2026).DOI
  11. [11]Fedorov, S. A. et al. Thermal intermodulation noise in cavity-based measurements. Optica 7, 1609–1616 (2020).DOI
  12. [12]Leijssen, R., La Gala, G. R., Freisem, L., Muhonen, J. T. & Verhagen, E. Nonlinear cavity optomechanics with nanomechanical thermal fluctuations. Nature Communications 8, 16024 (2017).
  13. [13]F'touni, H. et al. Thermal conductivity of silicon nitride membranes is not sensitive to stress. Physical Review B 92, 125439 (2015).DOI
  14. [14]Snell, N., Zhang, C., Mu, G., Bouchard, A. & St-Gelais, R. Heat Transport in Silicon Nitride Drum Resonators and its Influence on Thermal Fluctuation-Induced Frequency Noise. Physical Review Applied 17, 044019 (2022).
  15. [15]Piller, M. et al. Thermal radiation dominated heat transfer in nanomechanical silicon nitride drum resonators. Applied Physics Letters 117, 034101 (2020).
  16. [16]Martini, P., Kanellopulos, K. & Schmid, S. Design optimization of silicon nitride nanomechanical resonators for thermal infrared detectors: A guide through key figures of merit. AIP Advances 16, 015020 (2026).
  17. [17]Kanellopulos, K. et al. Stress-Dependent Optical Extinction in Low-Pressure Chemical Vapor Deposition Silicon Nitride Measured by Nanomechanical Photothermal Sensing. Nano Letters 24, 11262–11268 (2024).DOI
  18. [18]Habermehl, S. Coefficient of thermal expansion and biaxial Young’s modulus in Si-rich silicon nitride thin films. Journal of Vacuum Science & Technology A 36, 021517 (2018).DOI
  19. [19]Sadeghi, P. et al. Thermal Transport and Frequency Response of Localized Modes on Low-Stress Nanomechanical Silicon Nitride Drums Featuring a Phononic-Band-Gap Structure. Physical Review Applied 14, 024068 (2020).DOI
  20. [20]Giesriegl, A. et al. HF Etching and Silanization: Evidence for the Role of Surface Hydroxyl Groups in Silicon Nitride Resonator Loss (2026). Preprint at arXiv:2606.26838.arxiv.org/abs/2606.26838
  21. [21]Khan, A., Philip, J. & Hess, P. Young’s modulus of silicon nitride used in scanning force microscope cantilevers. Journal of Applied Physics 95, 1667–1672 (2004).
  22. [22]Fedorov, S. A. et al. Generalized dissipation dilution in strained mechanical resonators. Physical Review B 99, 054107 (2019).DOI
  23. [23]Bereyhi, M. J. et al. Hierarchical tensile structures with ultralow mechanical dissipation. Nature Communications 13, 3097 (2022).DOI
  24. [24]Hadley, L. N. & Dennison, D. M. Reflection and Transmission Interference Filters Part I. Theory. JOSA 37, 451–465 (1947).DOI
  25. [25]Cheng, D. K. Field and Wave Electromagnetics (Pearson Education Limited, 2013).
  26. [26]Luhmann, N. et al. Ultrathin 2 nm gold as impedance-matched absorber for infrared light. Nature Communications 11, 2161 (2020).DOI
  27. [27]Kischkat, J. et al. Mid-infrared optical properties of thin films of aluminum oxide, titanium dioxide, silicon dioxide, aluminum nitride, and silicon nitride. Applied Optics 51, 6789–6798 (2012).DOI
  28. [28]Rakić, A. D., Djurišić, A. B., Elazar, J. M. & Majewski, M. L. Optical properties of metallic films for vertical-cavity optoelectronic devices. Applied Optics 37, 5271–5283 (1998).pubmed.ncbi.nlm.nih.gov/18286006
  29. [29]Franta, D., Nečas, D., Ohlídal, I. & Giglia, A. Optical characterization of SiO2 thin films using universal dispersion model over wide spectral range. In Optical Micro- and Nanometrology VI, vol. 9890, 989014 (SPIE, 2016).
  30. [30]Franta, D. et al. Temperature-dependent dispersion model of float zone crystalline silicon. Applied Surface Science 421, 405–419 (2017).DOI
  31. [31]Pfeiffer, M. H. P. et al. Photonic Damascene process for integrated high-Q microresonator based nonlinear photonics. Optica 3, 20–25 (2016).DOI
  32. [32]Kitamura, R., Pilon, L. & Jonasz, M. Optical constants of silica glass from extreme ultraviolet to far infrared at near room temperature. Applied Optics 46, 8118–8133 (2007).pubmed.ncbi.nlm.nih.gov/18026551
  33. [33]Bramson, M. A. Infrared Radiation: A Handbook for Applications, with a Collection of Reference Tables (Plenum Press, 1968).
  34. [34]Zhang, C. et al. Enhanced Bandwidth in Radiation Sensors Operating at the Fundamental Temperature Fluctuation Noise Limit. Nano Letters 25, 14660–14667 (2025).arxiv.org/abs/2505.21678
  35. [35]Richards, P. L. Bolometers for infrared and millimeter waves. Journal of Applied Physics 76, 1–24 (1994).DOI
  36. [36]Roukes, M. L. 1/f frequency noise in mechanical resonators scales inversely with volume, not with quality factor (2026). Preprint at arXiv:2609.16668.arxiv.org/abs/2609.16668
  37. [37]Kanellopulos, K. & Schmid, S. 1/f frequency-noise reduction in nanomechanical resonators by dissipation dilution (2026). Preprint at arXiv:2610.16711.arxiv.org/abs/2610.16711
  38. [38]Pisani, M. B., Ren, K. K., Kao, P. & Tadigadapa, S. Application of Micromachined Y-Cut-Quartz Bulk Acoustic Wave Resonator for Infrared Sensing. Journal of Microelectromechanical Systems 20, 288–296 (2011).DOI
  39. [39]Hui, Y. & Rinaldi, M. High performance NEMS resonant infrared detector based on an aluminum nitride nano-plate resonator. In 2013 Transducers & Eurosensors XXVII: The 17th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS & EUROSENSORS XXVII), 968–971 (2013).DOI
  40. [40]Hui, Y., Gomez-Diaz, J. S., Qian, Z., Alù, A. & Rinaldi, M. Plasmonic piezoelectric nanomechanical resonator for spectrally selective infrared sensing. Nature Communications 7, 11249 (2016).DOI
  41. [41]Qian, Z., Kang, S., Rajaram, V. & Rinaldi, M. Narrowband MEMS resonant infrared detectors based on ultrathin perfect plasmonic absorbers. In 2016 IEEE SENSORS, 1–3 (2016).DOI
  42. [42]Laurent, L., Yon, J.-J., Moulet, J.-S., Roukes, M. & Duraffourg, L. 12-μm-Pitch Electromechanical Resonator for Thermal Sensing. Physical Review Applied 9, 024016 (2018).DOI
  43. [43]Piller, M., Luhmann, N., Chien, M.-H. & Schmid, S. Nanoelectromechanical infrared detector. In Optical Sensing, Imaging, and Photon Counting: From X-Rays to THz 2019, vol. 11088, 9–15 (SPIE, 2019).
  44. [44]Qian, Z., Rajaram, V., Kang, S. & Rinaldi, M. High figure-of-merit NEMS thermal detectors based on 50-nm thick AlN nano-plate resonators. Applied Physics Letters 115, 261102 (2019).DOI
  45. [45]Zhang, Y., Hosono, S., Nagai, N., Song, S.-H. & Hirakawa, K. Fast and sensitive bolometric terahertz detection at room temperature through thermomechanical transduction. Journal of Applied Physics 125, 151602 (2019).
  46. [46]Hui, Y., Kang, S., Qian, Z. & Rinaldi, M. Uncooled Infrared Detector Based on an Aluminum Nitride Piezoelectric Fishnet Metasurface. Journal of Microelectromechanical Systems 30, 165–172 (2021).DOI
  47. [47]Piller, M. et al. Thermal IR Detection With Nanoelectromechanical Silicon Nitride Trampoline Resonators. IEEE Sensors Journal 23, 1066–1071 (2023).arxiv.org/abs/2105.03999
  48. [48]Xi, Z. et al. Room-Temperature Mid-Infrared Detection Using Metasurface-Absorber-Integrated Phononic Crystal Oscillator. Laser & Photonics Reviews 19, e00498 (2025).DOI
  49. [49]Gülseren, M. E. et al. High responsivity IR sensing based on reflectometric RF MEMS. Nature Communications 17, 7625 (2026).DOI
  50. [50]Blaikie, A., Miller, D. & Alemán, B. J. A fast and sensitive room-temperature graphene nanomechanical bolometer. Nature Communications 10, 4726 (2019).DOI
  51. [51]Papas, D., Ou, J.-Y., Plum, E. & Zheludev, N. I. Optomechanical metamaterial nanobolometer. APL Photonics 6, 126110 (2021).DOI
  52. [52]Vicarelli, L., Treducci, A. & Pitanti, A. Micromechanical Bolometers for Subterahertz Detection at Room Temperature. ACS Photonics 9, 360–367 (2022).DOI
  53. [53]Zhang, C. et al. High detectivity terahertz radiation sensing using frequency-noise-optimized nanomechanical resonators. APL Photonics 9, 126105 (2024).
  54. [54]Alborghetti, L. et al. Enhanced Sensitivity of Sub-THz Thermomechanical Bolometers Exploiting Vibrational Nonlinearity. ACS Photonics 13, 58–66 (2026).DOI
  55. [55]He, Z.-H. et al. Uncooled infrared imaging using a single trampoline-based optomechanical thermal detector. Photonics Research 14, 587–594 (2026).DOI
  56. [56]Das, A., Mah, M. L., Hunt, J. & Talghader, J. J. Thermodynamically limited uncooled infrared detector using an ultra-low mass perforated subwavelength absorber. Optica 10, 1018–1028 (2023).
  57. [57]Yu, Y. et al. Uncooled low-noise optomechanical sensors on thin-film lithium niobate. Light: Science & Applications 15, 389 (2026).DOI
  58. [58]Zhang, C. & St-Gelais, R. Demonstration of frequency stability limited by thermal fluctuation noise in silicon nitride nanomechanical resonators. Applied Physics Letters 122, 193501 (2023).DOI

Paper details

vlnc:W_8kq4zbbs
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 1

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents