betaFeedback

WorksComputer Science

PathStream: Towards Streaming Diagnostic Copilots for Whole-Slide Pathology

Abstract

Pathologists reach a diagnosis by integrating morphological evidence across regions and magnifications along viewing trajectories. Existing pathology AI rarely reflects this process: models predict from selected image regions, answer questions within fixed visual contexts, or navigate slides autonomously. We formalize pathologist-led streaming diagnosis, in which the pathologist controls navigation while a copilot selectively describes incoming views and synthesizes accumulated evidence into a final diagnosis. We record five pathologists' viewing trajectories on 1,791 TCGA whole-slide images (WSIs) spanning ten organs, with response labels, morphological descriptions, and session-level findings and diagnoses. We construct PathStreamBench to assess response timing, morphological description, and session-level diagnosis, alongside auxiliary video understanding. We introduce PathStream, which jointly learns streaming responses and diagnosis through two-stage training, with a diagnosis-attention loss guiding attention during diagnosis to relevant visual and textual evidence accumulated as the examination unfolds. PathStream outperforms 14 vision-language models and three domain-fine-tuned baselines on the core tasks, achieving a trajectory WSI Relevance score of 77.87, surpassing the strongest domain-fine-tuned baseline's 62.76. Without additional training, its diagnostic capabilities generalize to new educational pathology videos, three external centers, and an unseen organ.

Introduction

Histopathological diagnosis develops through a sequence of observations: pathologists examine different tissue regions of a whole-slide image (WSI) at multiple magnifications, interpret local morphology, and combine findings to reach a diagnostic conclusion. These viewing trajectories vary with individual experience and clinical practice.

However, existing pathology AI is generally not designed for this ongoing, pathologist-led examination: static approaches make slide-level predictions from a selection of image regions or answer questions based on fixed visual context [14, 16, 23, 24], while autonomous agents select their own trajectories [25, 30]. We therefore formalize pathologist-led streaming diagnosis (Figure 1), in which the pathologist directs slide navigation while a diagnostic copilot follows the evolving examination to interpret findings and support diagnosis. By preserving the pathologist’s control over navigation, this setting is designed to accommodate diverse examination practices and integrate AI assistance into existing diagnostic workflows.

Figure 1. Motivation of streaming diagnostic copilots. Static models such as multiple instance learning (MIL) and pathology vision-language models (VLMs) aggregate patches or answer questions about a given visual context, while pathology agents select their own viewing trajectories. The proposed PathStream follows the pathologist’s navigation, describes the evolving morphology, and integrates accumulated evidence into a final diagnosis.

An ideal streaming copilot in this setting should therefore adapt its responses as new views arrive, providing timely descriptions of newly observed morphology while remaining silent during continued inspection of similar views. Its descriptions should accurately capture the morphology observed in different tissue regions at multiple magnifications. Beyond interpreting individual views, the copilot should retain and integrate relevant findings from earlier observations to produce a final diagnosis at session end.

Training such a copilot requires annotated viewing trajectories that link response timing and morphological interpretation with diagnostic conclusions. We therefore record viewing trajectories as five pathologists examine 1,791 WSIs from 1,791 patients across ten organs in The Cancer Genome Atlas (TCGA) [27]. Each trajectory is paired with response labels, morphological descriptions for response frames, and session-level microscopic findings and diagnoses. From the held-out test video sessions, we construct PathStreamBench with four tasks: response timing, streaming morphological description, session-level diagnosis, and auxiliary video understanding covering visual content and temporal relations. External validation assesses diagnostic generalization beyond TCGA: a private three-center cohort tests transfer to new clinical centers, while the PEAN skin cohort [18] tests generalization to unseen organ.

We further introduce PathStream, a streaming copilot for pathologist-led diagnosis that follows the pathologist’s slide navigation, responds selectively as new views arrive, and integrates accumulated findings into a final diagnosis. We train PathStream in two stages: the first establishes basic streaming capabilities in response control, morphological description, and diagnosis; the second focuses on strengthening session-level diagnostic synthesis. Across both stages, a diagnosis-attention loss guides the model to integrate accumulated frames and descriptions during diagnosis generation. On PathStreamBench, we compare PathStream with 14 general-purpose, streaming, and pathology/medical vision-language models (VLMs) and fine-tuned baselines. PathStream outperforms all baselines in the response timing, morphological description, and diagnostic synthesis required for streaming diagnosis. Without additional training, its diagnostic capabilities also generalize to educational pathology videos, new clinical centers, and an unseen organ. In summary, the contributions of this work are:

  • We formalize pathologist-led streaming diagnosis: the pathologist controls slide navigation while a copilot selectively describes morphology as new views arrive and integrates accumulated evidence into a final diagnosis.

  • We curate viewing trajectories from 1,791 TCGA WSIs spanning ten organs, annotated for response timing, morphological description, and session-level diagnosis. We construct PathStreamBench to evaluate these capabilities, complemented by an auxiliary video understanding task.

  • We introduce PathStream, which jointly learns streaming responses and diagnostic synthesis and outperforms both original and domain-fine-tuned VLMs on the core streaming diagnostic tasks. It achieves a trajectory WSI Relevance score of 77.87, compared with 62.76 for the strongest domain-finetuned baseline, and generalizes without additional training to educational pathology videos, 3 new clinical centers, and an unseen organ.

Related Work

Whole-slide Modeling in Pathology. In whole-slide prediction, multiple-instance learning (MIL) aggregates patch features under slide-level supervision. Attention pooling and clustering-based objectives identify informative tissue regions [10, 14]. Transformers and hierarchical encoders model relationships between regions and across scales [5, 24], while large-scale pretraining produces transferable slide representations [34]. A complementary direction learns from how pathologists examine slides: eye-tracking records guide regional attention, and viewport trajectories support prediction of viewing paths [2, 18].

Pathology Vision-Language Models and Agents. Pathology VLMs align images with descriptions and reports to support recognition and retrieval [6, 15]. Instruction tuning extends these representations to morphological description and diagnostic question answering [16, 23], with models operating on whole slides [11] or pathology video clips [28]. Reasoning supervision and reinforcement learning further support diagnostic reasoning [38]. VLM-based agents select regions and change magnification to collect diagnostic evidence [25]. Recorded expert navigation, gaze, and narration can guide their visual grounding and examination procedures [30, 31]. These agents gather evidence through model-directed navigation. PathStream instead follows the pathologist’s examination, jointly learning response timing, morphological interpretation, and diagnostic synthesis.

Streaming Video Understanding. Streaming video understanding studies how models interpret and respond to visual inputs as they arrive. Temporally aligned training interleaves frames and language [3, 4]. Recent methods learn when to respond through explicit decision modules or reinforcement learning [21, 33], retain historical context through memory or cached states [35, 37], and reason while continuing to observe [7]. In parallel, benchmarks evaluate current-event understanding and contextual reasoning [13], recall of earlier events and responses triggered by new evidence [19], and sustained frame–text alignment over long streams [35]. PathStreamBench extends streaming evaluation to pathologist-led streaming diagnosis through four tasks: response timing, streaming morphological description, session-level diagnosis, and auxiliary pathology video understanding. These tasks assess timely interpretation of tissue observations and diagnostic synthesis from accumulated evidence.

Pathologist-Led Streaming Diagnosis

Problem Formulation

We define pathologist-led streaming diagnosis as sequential assistance during WSI review, with navigation controlled by the pathologist. Let X=(x1,…,xT)X = (x_1, \ldots, x_T) denote the orordered frames reconstructed from the pathologist’s viewing trajectory, each representing the field of view at that time.

At time tt, the model uses only the frames observed so far x1:tx_{1:t}, the initial assistance request uu, and its own preceding outputs o1:t−1o_{1:t-1} to remain silent or generate a textual response:

ot=fθ(x1:t,u,o1:t−1)∈{silence}∪Y,(1)o_t = f_\theta(x_{1:t}, u, o_{1:t-1}) \in\{\text{silence}\} \cup\mathcal{Y}, \tag*{(1)}

where fθf_\theta denotes the model and Y\mathcal{Y} the space of textual responses. At session end, the model produces a final diagnosis zz from the observed frames and its generated morphological descriptions.

This setting requires (1) response timing: responding to new morphological information while remaining silent during continued inspection of similar views; (2) morphological interpretation: accurately describing morphology across tissue regions and magnification levels; and (3) diagnostic synthesis: integrating relevant visual and textual evidence across the full session.

Trajectory Acquisition and Supervision

Pathologist-Guided Trajectory Acquisition

We record pathologists’ WSI examinations as viewing trajectories using a customized viewer. Pathologists navigate through panning, region selection and zooming, while the viewer records timestamped viewport samples at 10 Hz. At the end of each review, the pathologist provides microscopic findings and a diagnostic conclusion. All diagnoses are independently verified by a sixth, supervising pathologist.

Using this workflow, five pathologists review 1,791 WSIs spanning 10 organ categories from TCGA, and we collect trajectories from 83 additional WSIs in a private three-center cohort covering six of these organ categories. We complement these recordings with 90 WSIs of a new organ, skin, from the publicly released PEAN data [18], which provide viewing trajectories on a 50 Hz timebase and diagnostic conclusions. Each WSI contains one viewing trajectory. For TCGA, the private cohort, and PEAN, we uniformly sample each trajectory at 1 Hz and reconstruct a video using the recorded WSI coordinates and temporal information. Figure 2(a) shows the cohorts’ organ distribution.

Figure 2. Data curation and PathStreamBench construction. (a) Organ distribution across the TCGA, private, and PEAN cohorts, followed by pathologist-guided slide review, trajectory replay, and expert annotation of response points and morphology. (b) The benchmark evaluates response timing, streaming morphological description, session-level diagnosis, and auxiliary pathology video understanding along the viewing sequence. (c) Distribution of PathStreamBench samples across the four tasks and their categories.

Response Annotation and Frame Grouping

An ideal copilot should promptly summarize key morphological features as the pathologist shifts to a new view, guiding efficient inspection, and remain silent while similar morphology persists. Pathologists therefore review the reconstructed trajectory videos and individually confirm response frames that introduce new morphological information. They mark these frames as response points and annotate their morphology; all other frames are labeled as silence.

These response points partition each trajectory into contiguous frame groups conveying similar pathological visual information. Each group begins with a response frame and ends immediately before the next response frame, with the final group extending to the end of the sequence. We represent each trajectory as:

T=((G1,d1),…,(GK,dK)),(2)\mathcal{T} = ((G_1,d_1),\ldots,(G_K,d_K)), \tag*{(2)}

where Gk=(xbk,…,xek)G_k=(x_{b_k},\ldots,x_{e_k}) is the kk-th frame group with first and last frame indices bkb_k and eke_k, dkd_k is the morphological description of its response frame xbkx_{b_k}, and KK is the number of groups. Frame-group statistics are detailed in supplementary Sec. B.

PathStreamBench

We split the 1,791 TCGA trajectories into 988 for training, 400 for validation, and 403 for testing. We construct PathStreamBench from the test split to evaluate pathologist-led streaming diagnosis through three progressively demanding tasks: response timing, morphological interpretation, and diagnostic synthesis (Figure 2(b)).

Task 1: Response Timing. This task assesses response timing across different response–silence patterns (see supplementary Sec. D.4). Models receive frames sequentially and must respond to local visual changes while remaining silent during continued inspection of visually similar frames.

Task 2: Streaming Morphological Description. Building on Task 1, this task requires models to respond at appropriate moments and accurately describe morphology across magnification levels. Generated descriptions are compared with pathologist annotations.

Task 3: Session-Level Diagnosis. This task extends Task 2 to complete viewing sessions. Models must provide timely, accurate morphological descriptions without unnecessary repetition and integrate the accumulated findings into a final diagnosis at session end. We additionally include 500 public educational pathology videos from YouTube [28] to assess generalizations to educational slide reviews.

Task 4: Pathology Video Understanding. This auxiliary task complements streaming diagnosis by assessing recognition and temporal reasoning. Models answer multiple-choice questions about visual content, temporal change, and temporal order in trajectory clips.

Figure 2(c) summarizes the sample distribution: 500 cases each for Tasks 1 and 2, 403 WSI trajectories and 500 videos for Task 3, and 420 MCQs for Task 4.

PathStream

Model Overview

Figure 3 illustrates PathStream, a copilot for pathologist-led streaming diagnosis. During review, the model outputs description as the view changes and remains silent during continued inspection of similar frames. The observed frames and generated descriptions form the visual and textual history used for final diagnosis. We jointly supervise streaming responses and final diagnoses, with a diagnosis-attention loss guiding the use of historical evidence.

Figure 3. PathStream overview. PathStream jointly learns response timing, morphological description, and final diagnosis from a causal sequence of frames and responses, with diagnostic attention supervision guiding evidence integration.

Built on Qwen3-VL-4B-Instruct [1] and VideoLLM-online [3] PathStream is trained on complete chronological video sequences. Each sequence interleaves frames with annotated responses and ends with the pathologist-verified diagnosis. We apply LoRA [8] (r=128r = 128) to the model’s attention and feed-forward layers and train the adapters together with the vision–language merger MLPs while freezing all other parameters. Implementation details in Sec. C.

Streaming Generation with Response Control

PathStream learns to describe morphology as the view changes and remain silent during continued inspection of similar frames. Response labels encode pathologist-confirmed morphological changes: each frame group’s first frame is marked for response, while subsequent similar frames are marked for silence. After each frame, the gate loss LgL_g supervises end-of-sequence (EOS) token prediction [3]: EOS indicates silence, whereas a non-EOS token initiates a response. At annotated response points, the description loss LdL_d supervises description generation using the pathologist’s annotation of the current frame.

Diagnostic Evidence Alignment

Streaming responses describe frame-level morphology, whereas session-level diagnosis requires integrating relevant findings across the accumulated frames and descriptions. At session end, the model generates a diagnosis upon request. The diagnosis loss LzL_z supervises this output using the pathologist-verified diagnosis. To guide diagnosis generation, we construct smoothed attention targets [9] over supporting historical frames and descriptions.

As illustrated in Figure 4, a language model matches annotated frame descriptions to the pathologist-provided microscopic findings. Each matched frame group contributes its response frame and description as a supporting evidence pair, linking session-level findings to specific observations. These pairs define separate targets PzmP_z^m over historical visual (m=vm = v) and description (m=tm = t) tokens.

Figure 4. Diagnostic evidence attention alignment. Matching descriptions to microscopic findings guides attention to supporting evidence during diagnosis generation.

Let AumA_u^m denote the model’s attention distribution for diagnosis token uu. We align this distribution with the evidence target by minimizing

Lza=Em,u[DKL(Aum∥Pzm)].(3)\mathcal{L}_{za} = \mathbb{E}_{m,u}\left[D_{\mathrm{KL}}\left(A_u^m \parallel P_z^m\right)\right]. \tag*{(3)}

Evidence matching, target construction, and attention computation are detailed in supplementary Sec. C.2.

Training Objective and Optimization

We use token-level cross-entropy for LgL_g, LdL_d, and LzL_z:

Lr=−1∣Ir∣∑u∈Irlog⁡pθ(yu∣hu),(4)\mathcal{L}_r = -\frac{1}{\lvert I_r\rvert}\sum_{u\in I_r}\log p_\theta(y_u \mid h_u), \tag*{(4)}

where r∈{g,d,z}r \in\{g,d,z\}, IrI_r contains the supervised token positions, and yuy_u and huh_u denote the target token and its preceding visual and textual context. We combine these losses with diagnostic attention supervision to form the overall objective at training stage s∈{1,2}s \in\{1,2\}:

L(s)=wg(s)Lg+wd(s)Ld+wz(s)Lz+λLza.(5)\mathcal{L}^{(s)} = w_g^{(s)}\mathcal{L}_g + w_d^{(s)}\mathcal{L}_d + w_z^{(s)}\mathcal{L}_z + \lambda\mathcal{L}_{za}. \tag*{(5)}

We train on complete chronological sessions in two stages. Stage 1 jointly trains the model for response control, morphological description, and diagnostic synthesis. Stage 2 continues training with greater emphasis on diagnosis while retaining the response-control and description objectives. Token-level supervision, loss weights, and optimization settings are detailed in supplementary Secs. C.1 and C.3.

Experiments

Experimental Setup

Comparison models. We train both PathStream stages on 988 training trajectories and select loss weights and LoRA rank using 400 validation trajectories. We benchmark PathStream against 14 general, streaming, and pathology/medical VLMs on the 403 held-out test trajectories. The six general VLMs are InternVL3.5-8B [32], Qwen3-VL-4B-Instruct and Qwen3-VL-8B-Instruct [1], GPT-6-luna [20], Qwen3.6-35B-A3B [26], and Qwen3.8-Flash [22]. The six streaming VLMs are VideoLLM-online-8B-v1plus [3], Stream-ingVLM [35], LiveCC-7B-Instruct [4], AURA [17], MOSS-VL-Realtime [29], and MMDuet2 [33]. Pathology/medical VLMs include Patho-R1-7B [38] and Lingshu-32B [36]. We also fine-tune LiveCC-7B, MMDuet2, and Qwen3-VL-4B (whose SFT variant is also reported as “w/o diagnosis attention” in the Stage 1 ablation) on our training data as domain SFT baselines (supplementary Sec. E).

Evaluation protocol. General and pathology/medical VLMs receive each frame with earlier frames and their own generated descriptions, and output either silent or a morphological description. Streaming VLMs use their native response mechanisms and streaming state. Task 3 ends with a diagnosis request. For Task 4, models receive a video clip and answer a multiple-choice question. Details are provided in supplementary Secs. D.1 and D.2.

Evaluation metrics. For Task 1, gate Macro-F1 averages the F1 scores for response and silence. Task 2 uses ROUGE-L [12] and CONCH text similarity [15]. For Task 3, we use GPT-6-luna to evaluate WSI Precision and WSI Relevance [11]. WSI Precision measures how much of the reference diagnosis is correctly captured, while WSI Relevance measures how well the generated diagnosis agrees with the reference. Task 4 uses accuracy. Diagnosis scoring is detailed in supplementary Sec. D.3. Higher values indicate better performance for all metrics. Pathologists additionally reviewed a subset of generated descriptions and diagnoses, and their qualitative assessments were consistent with the CONCH, WSI Precision, and WSI Relevance scores.

Comparative Results

Table 1 shows that PathStream better supports pathologist-led streaming diagnosis than the 14 models evaluated with their original checkpoints. PathStream provides timely updates as the pathologist’s view changes, achieving 95.10 gate Macro-F1 in Task 1, 16.34 points above the strongest baseline. It also interprets morphology and integrates accumulated evidence into a diagnosis, reaching 51.55 CONCH in Task 2 and 77.87 trajectory WSI Relevance in Task 3, surpassing the strongest baselines by 15.39 and 46.89 points, respectively. Diagnostic synthesis further generalizes to educational videos, with 50.36 WSI Relevance, a 28.26-point improvement over the strongest baseline. For visual and temporal understanding, PathStream ties with Qwen3.8-Flash for the highest Task 4 accuracy at 52.14%. PathStream therefore provides more effective assistance during review.

ModelTask 1 Gate Macro-F1Task 2 Description ROUGE-LTask 2 Description CONCHTask 3 Diagnosis Video-PrecisionTask 3 Diagnosis Video-RelevanceTask 3 Diagnosis Trajectory-PrecisionTask 3 Diagnosis Trajectory-RelevanceTask 4 QA Accuracy
General VLMs
InternVL3.5-8B64.8613.7027.5010.7312.6716.6030.7448.33
Qwen3-VL-4B-Instruct64.7111.2222.738.265.2914.679.2949.29
Qwen3-VL-8B-Instruct57.140.450.699.038.0316.8418.7345.00
GPT-6-luna78.7618.3836.1615.2510.1417.7615.6550.71
Qwen3.6-35B-A3B43.756.6914.9217.4618.2220.8825.2851.43
Qwen3.8-Flash45.2115.6132.9718.8322.1019.5430.9852.14
Streaming VLMs
VideoLLM-online28.911.306.311.322.382.323.5811.19
StreamingVLM49.782.185.250.921.091.442.6335.48
LiveCC-7B-Instruct39.714.3012.055.238.148.4212.5842.62
AURA32.281.552.015.565.6220.7423.6237.62
MOSS-VL-Realtime48.965.319.896.224.459.808.9233.10
MMDuet251.234.858.640.570.803.132.8840.48
Pathology / Medical VLMs
Patho-R1-7B39.9011.1522.3416.3211.5820.1614.1742.14
Lingshu-32B51.495.0918.6410.3111.1715.2327.5250.48
Domain SFT baselines
LiveCC-7B + SFT88.6026.5147.3336.6237.7856.4560.3450.00
MMDuet2 + SFT89.7025.3245.5836.6836.9754.6658.9048.33
Qwen3-VL-4B + SFT93.9727.8248.3532.4633.5660.5062.7650.00
PathStream95.1031.2751.5548.5550.3675.2277.8752.14

Table 1. Trajectory and video benchmark results. Tasks 1, 2, and 4 use trajectory inputs. All scores are multiplied by 100; higher is better. Bold and underlined scores indicate the best and second-best reported results in each column.

These comparisons highlight distinct gaps in existing models: general VLMs struggle with diagnostic synthesis, streaming VLMs have limited morphological understanding, and pathology/medical VLMs lack reliable response timing during sequential review. Fine-tuning LiveCC-7B, MMDuet2, and Qwen3-VL-4B on our data substantially improves all three capabilities, narrowing the gaps in response timing and morphological description. PathStream nevertheless retains an advantage, particularly in diagnostic synthesis: it exceeds the strongest SFT baselines by 1.13 points in gate Macro-F1 and 3.20 points in description CONCH, with larger gains of 15.11 and 12.58 points in trajectory and video WSI Relevance, respectively.

Figure 5 shows that response timing and description quality remain stable throughout review, while PathStream maintains WSI Precision and WSI Relevance above 65 across the evaluated session lengths. Its advantage also holds across all ten TCGA organs (Figure 6). Domain SFT improves MMDuet2 across these organs, while PathStream achieves higher overall scores at Stage 1 and further improves at Stage 2. Details of organ-wise score aggregation and full results are provided in the supplementary material (Table S2 and Figure S2).

Figure 5. Streaming analysis. (a) Response timing and description quality during review. (b) Diagnosis quality by session length.

Figure 6. Organ-wise comparison. Four-task performance across ten TCGA organs.

Table S2. Full trajectory and video benchmark results. Tasks 1–2 appear above and Tasks 3–4 below. Gate, description, and QA use trajectory inputs. Video and trajectory diagnosis metrics are WSI Precision (WSI-P), WSI Relevance (WSI-R), and ROUGE-L F1. Scores are multiplied by 100. Bold and underlining mark the best and second-best scores per column.

ModelTask 1 GateTask 1 Macro-F1Task 2 GateTask 2 Macro-F1Task 2 Description ROUGE-LTask 2 Description CONCH
General VLMs
InternVL3.5-8B64.8642.5613.7027.50
Qwen3-VL-4B-Instruct64.7160.2411.2222.73
Qwen3-VL-8B-Instruct57.1435.880.450.69
GPT-6-luna78.7678.0318.3836.16
Qwen3.6-35B-A3B43.7552.016.6914.92
Qwen3.8-Flash45.2150.6115.6132.97
Streaming VLMs
VideoLLM-online28.9132.641.306.31
StreamingVLM49.7845.202.185.25
LiveCC-7B-Instruct39.7138.354.3012.05
AURA32.2834.841.552.01
MOSS-VL-Realtime48.9653.725.319.89
MMDuet251.2350.484.858.64
Pathology / Medical VLMs
Patho-R1-7B39.9036.4011.1522.34
Lingshu-32B51.4950.605.0918.64
Domain SFT baselines
LiveCC-7B + SFT88.6085.6626.5147.33
MMDuet2 + SFT89.7089.3425.3245.58
Qwen3-VL-4B + SFT93.9791.9527.8248.35
PathStream95.1092.3431.2751.55
ModelTask 3 Gate Macro-F1Task 3 Description ROUGE-LTask 3 Description CONCHTask 3 Video diagnosis WSI-PTask 3 Video diagnosis WSI-RTask 3 Video diagnosis ROUGE-LTask 3 Trajectory diagnosis WSI-PTask 3 Trajectory diagnosis WSI-RTask 3 Trajectory diagnosis ROUGE-LTask 4 QA Acc.
General VLMs
InternVL3.5-8B35.8714.6234.8010.7312.6710.4116.6030.7419.6148.33
Qwen3-VL-4B-Instruct47.6516.1629.158.265.296.6714.679.298.8549.29
Qwen3-VL-8B-Instruct49.8111.2615.709.038.039.4916.8418.7315.0445.00
GPT-6-luna60.7516.8732.4015.2510.1412.1717.7615.6514.5650.71
Qwen3.6-35B-A3B54.1615.5330.6717.4618.2221.7420.8825.2827.39<u>51.43</u>
Qwen3.8-Flash47.4415.3529.6318.8322.1017.6119.5430.9823.7552.14
Streaming VLMs
VideoLLM-online30.580.221.041.322.381.942.323.583.7311.19
StreamingVLM46.112.033.870.921.091.521.442.632.1335.48
LiveCC-7B-Instruct44.282.555.605.238.146.248.4212.588.1142.62
AURA31.680.390.565.565.626.6520.7423.6217.4637.62
MOSS-VL-Realtime54.298.0615.286.224.455.089.808.929.2333.10
MMDuet237.291.452.780.570.800.533.132.882.1540.48
Pathology / Medical VLMs
Patho-R1-7B39.5911.0721.3016.3211.588.3720.1614.1712.2742.14
Lingshu-32B41.3214.6834.5810.3111.179.8615.2327.5219.0450.48
Domain SFT baselines
LiveCC-7B + SFT85.3025.5346.7736.62<u>37.78</u>34.8056.4560.34<u>64.77</u>50.00
MMDuet2 + SFT87.3924.7644.34<u>36.68</u>36.9735.5054.6658.9064.3348.33
Qwen3-VL-4B + SFT<u>91.30</u><u>33.90</u><u>52.30</u>32.4633.56<u>35.79</u><u>60.50</u><u>62.76</u>62.4950.00
PathStream92.4434.9454.2248.5550.3646.4275.2277.8778.0652.14

Table S2.

Figure S2. Overall performance across ten TCGA organs. Each axis shows the weighted four-task score for one organ, with higher scores farther from the center. The curves compare both PathStream stages, 14 baselines, and three domain SFT variants.

Ablation Studies

We individually ablate the four losses in Eq. (5), using PathStream Stage 1 as the reference (Table 2). See Table S3 for full results and Sec. F for loss-weight and LoRA-rank ablations.

ModelTask 1 Gate Macro-F1Task 2 Description ROUGE-LTask 2 Description CONCHTask 3 Diagnosis Video-PrecisionTask 3 Diagnosis Video-RelevanceTask 3 Diagnosis Trajectory-PrecisionTask 3 Diagnosis Trajectory-RelevanceTask 4 QA Accuracy
PathStream (Stage 1)94.6128.2048.7538.0739.0866.0368.2254.05
PathStream (Stage 2)95.1031.2751.5548.5550.3675.2277.8752.14
w/o diagnosis attention93.9727.8248.3532.4633.5660.5062.7650.00
w/o gate CE37.2430.6451.2532.4133.7562.4163.1350.00
w/o description CE92.433.3425.9831.8032.1737.9034.4750.00
w/o diagnosis CE94.0527.3748.117.928.381.434.6452.14

Table 2. Ablation results and training-stage comparison. PathStream (Stage 1) is the reference for the four objective ablations. PathStream (Stage 2) reports the complete two-stage model. Tasks 1, 2, and 4 use trajectory inputs. All scores are multiplied by 100; higher is better. Bold and underlined scores indicate the best and second-best reported results in each column.

ModelTask 1 Gate Macro-F1Task 2 Gate Macro-F1Task 2 Description ROUGE-LTask 2 Description CONCH
PathStream (Stage 1)<u>94.61</u>92.6528.2048.75
PathStream (Stage 2)95.10<u>92.34</u>31.2751.55
w/o diagnosis attention93.9791.9527.8248.35
w/o gate CE37.2434.01<u>30.64</u><u>51.25</u>
w/o description CE92.4389.643.3425.98
w/o diagnosis CE94.0591.8627.3748.11
ModelTask 3 Gate Macro-F1Task 3 Description ROUGE-LTask 3 Description CONCHTask 3 Video diagnosis WSI-PTask 3 Video diagnosis WSI-RTask 3 Video diagnosis ROUGE-L F1Task 3 Trajectory diagnosis WSI-PTask 3 Trajectory diagnosis WSI-RTask 3 Trajectory diagnosis ROUGE-L F1Task 4 QA Acc.
PathStream (Stage 1)92.0534.4253.28<u>38.07</u><u>39.08</u><u>38.62</u><u>66.03</u><u>68.22</u><u>68.37</u>54.05
PathStream (Stage 2)92.4434.9454.2248.5550.3646.4275.2277.8778.06<u>52.14</u>
w/o diagnosis attention91.3033.9052.3032.4633.5635.7960.5062.7662.4950.00
w/o gate CE35.88<u>34.88</u><u>53.58</u>32.4133.7536.1462.4163.1363.6350.00
w/o description CE90.452.6226.5531.8032.1712.2737.9034.4737.1550.00
w/o diagnosis CE91.9534.0852.677.928.383.231.434.643.07<u>52.14</u>

Table S3. Full ablation results and training-stage comparison. PathStream (Stage 1) is the reference for the four objective ablations; PathStream (Stage 2) is the complete two-stage model. Tasks 1 and 2 are shown above; Tasks 3 and 4 are shown below. Tasks 1, 2, and 4, and the gate and description metrics of Task 3, use trajectory inputs. Diagnosis metrics are WSI Precision (WSI-P), WSI Relevance (WSI-R), and ROUGE-L F1. All scores are multiplied by 100. Bold and <u>underlined</u> scores indicate the best and second-best reported results in each column.

Diagnostic attention primarily benefits final diagnosis. Removing diagnosis-attention supervision lowers trajectory WSI Precision and Relevance by 5.53 and 5.46 points, while gate and description scores each change by less than one point. Diagnosis also declines on educational pathology videos. This selective effect supports its role in focusing diagnosis on relevant historical evidence.

Joint supervision supports pathologist-led streaming diagnosis. Removing gate supervision lowers gate Macro-F1 from 94.61 to 37.24, while description quality is preserved. Removing description supervision reduces Task 2 ROUGE-L from 28.20 to 3.34 and CONCH from 48.75 to 25.98. Trajectory WSI Relevance also falls from 68.22 to 34.47 even with diagnosis supervision retained. Removing diagnosis supervision lowers trajectory WSI Relevance to 4.64, while response timing and description scores remain nearly unchanged. These results reveal complementary roles for the three objectives. Accurate morphological descriptions alone ensure neither appropriate response timing nor effective session-level diagnosis. Gate supervision teaches the model when to contribute during review, while morphological supervision supports both local interpretation and the observations used for diagnostic synthesis. Diagnosis supervision further teaches the model to integrate these observations into a conclusion. Joint learning thus connects timely morphological assistance during the examination with diagnosis from accumulated evidence.

Stage 2 strengthens diagnosis while maintaining streaming performance. Stage 2 improves trajectory WSI Precision and Relevance by 9.19 and 9.65 points, respectively. These gains show that increasing the weight of sparse diagnosis supervision improves diagnostic synthesis while maintaining response timing and description quality.

External Validation and Generalization

We evaluate TCGA-trained PathStream on the private three-center and PEAN skin cohorts without further training. Figure 8 shows that PathStream outperforms domain-fine-tuned Qwen3-VL-4B across all three metrics. It achieves 72.87 WSI Relevance on the private cohort, 23.64 points above the baseline. On PEAN, it achieves 63.33 WSI Precision and 65.90 WSI Relevance, with gains of 16.69 and 19.90 points, respectively. Both models perform worse outside TCGA, but PathStream shows smaller declines in WSI Precision and Relevance on both cohorts. Its WSI Relevance advantage on both external cohorts also exceeds the 15.11-point gain observed on TCGA. It therefore better preserves diagnostic quality across clinical centers and extends diagnostic synthesis to an organ absent from our training data.

Figure 8. External diagnostic generalization. PathStream and domain-fine-tuned Qwen3-VL-4B on the TCGA test set, the private three-center cohort, and the PEAN skin cohort. Left to right: diagnosis ROUGE-L F1, WSI Precision, and WSI Relevance.

Qualitative Analysis

Figure 7 compares Qwen3.6-35B-A3B and PathStream against pathologist annotations from the same WSI viewing sequence. PathStream follows the annotated response–silence pattern, describes the changing morphology, and reaches the reference diagnosis of invasive ductal carcinoma. In contrast, Qwen3.6-35B-A3B misinterprets morphology, responds unnecessarily, misses relevant updates, and incorrectly diagnoses a well-differentiated neuroendocrine tumor. This example shows how PathStream supports morphological interpretation and diagnosis as visual evidence accumulates across successive views during pathologist-led review. Full responses appear in supplementary Figure S3.

Figure 7. Streaming responses and final diagnoses. Qwen3.6-35B-A3B and PathStream outputs alongside pathologist annotations for the same WSI. Red text marks errors in descriptions, response timing, or diagnosis. Ellipses mark omitted frames or text.

Figure S3. Complete streaming responses and final diagnoses. Pathologist annotations and complete outputs from Qwen3.6-35B-A3B and PathStream at five selected time points in the same WSI viewing sequence, followed by the final diagnosis at the end of review. Red text highlights errors in morphological descriptions, response timing, or final diagnosis. Ellipses indicate omitted frames.

Conclusion

Here, we formalize pathologist-led streaming diagnosis, in which a copilot follows the pathologist’s examination and integrates evidence as it accumulates. We collect annotated WSI viewing trajectories and establish PathStreamBench to evaluate response timing, morphological interpretation, and session-level diagnosis. We further design PathStream, which delivers timely morphological descriptions, avoids redundant responses, and integrates the evidence into a final diagnosis. Experiments show that PathStream achieves superior performance and generalizes to new clinical centers and an organ unseen during training. PathStreamBench and PathStream lay the foundation for pathology copilots that support diagnosis as evidence unfolds.

Cohort Composition

Table S1 provides the WSI counts underlying the organ distribution in Figure 2(a).

Trajectory Processing and Frame Grouping

Before constructing model inputs, we exclude unusually long sessions dominated by prolonged pauses at a fixed viewport, typically caused by interruptions in the pathologist’s examination.

Viewing sessions contain a median of 22 frame groups (interquartile range 12–37), as shown in the top panel of Figure S1. In the example trajectory below the box plot, frames tit_i through ti+2t_{i+2} show similar morphology and belong to group GjG_j. At ti+3t_{i+3}, new morphology appears, and the pathologist marks this frame as the response point that starts group Gj+1G_{j+1}. Frame ti+4t_{i+4} shows similar morphology and remains in the same group.

Figure S1. Frame-group counts across sessions and group boundaries in an example trajectory.

Implementation Details

Visual inputs and context. PathStream processes frames chronologically, adding one new frame at each streaming step. The number of input frames varies with the clip or session length. Images are resized with their aspect ratios preserved under a budget of 100,352 pixels per frame. With 16×1616 \times16 patches and 2×22 \times2 spatial merging, each frame contributes at most 98 visual tokens, giving at most 98T98T visual tokens for a sequence of TT frames. The context budget is 24,576 tokens, shared by visual inputs, instructions, and textual history. If this budget is exceeded, the oldest complete turns are removed while retaining the instructions and the newest observations.

Shared Prediction Head. A shared vocabulary head predicts response-control tokens and autoregressively generates descriptions and the final diagnosis. At each step, this head maps the decoder output to a probability distribution over the model’s vocabulary. At a streaming decision point, the native tokens <|im_start|> and <|im_end|> represent starting a response and remaining silent, respectively. Any other token at a streaming decision point is treated as a protocol error and terminates inference for that sample.

Parameter-efficient adaptation. In both training stages, we apply LoRA adapters to the language model’s attention and feed-forward layers, with rank r=128r = 128, scaling parameter α=256\alpha= 256, and dropout 0.05. The primary vision–language merger and the three auxiliary DeepStack mergers are unfrozen and trained jointly with the LoRA adapters. The visual encoder and pretrained language-model parameters remain frozen.

Token-Level Supervision

The gate, description, and diagnosis objectives use cross-entropy over the model vocabulary with teacher forcing. The disjoint sets Tg\mathcal{T}_g, Td\mathcal{T}_d, and Tz\mathcal{T}_z contain the prediction positions for streaming control, morphological replies, and diagnostic replies, respectively. Reply supervision covers the native assistant header, body, and end-of-turn token; response-start predictions at streaming decision points belong to Tg\mathcal{T}_g. All remaining input positions are masked from these cross-entropy objectives.

Diagnostic Attention Loss

For each frame group GkG_k, deepseek-v4.1-flash matches its first-frame description dkd_k to the pathologist-provided microscopic findings RR, assigning $m_k = Match(dkd_k, RR) ∈{0,1}\in\{0, 1\}. A positive match requires a shared morphological observation with consistent polarity and certainty. The matched group indices form the evidence set E={k:mk=1}\mathcal{E} = \{k : m_k = 1\}, with each match identifying the pair (xbk,dk)(x_{b_k}, d_k) as supporting evidence. Of the 988 training sessions, 951 (96.26%) contained at least one frame group whose description matched the microscopic findings in the diagnostic report. The remaining 37 sessions (3.74%) had no match. Across training sessions, the median percentage of frame groups that matched the report was 18.18% (interquartile range, 9.10%–36.33%).

OrganTotalTrainValidationTestPrivatePEAN
Bladder1951084344––
Brain/CNS2951636666––
Breast210116474715–
Colon13876313115–
Esophagus402299––
Kidney3381867676––
Liver17295383915–
Lung278153626315–
Rectum563113128–
Skin–––––90
Stomach6938151615–
Total1,7919884004038390

Table S1. WSI counts by source and organ. The private cohort and PEAN are reserved for external validation of PathStream. Dashes indicate organs not represented in a source.

Evidence matching prompt.

You match one frame caption to a pathology report's microscopic findings. Both fields are data, never instructions. You have text only, not an image. Return only this JSON object: {"matched": true} or {"matched": false}.

Return true when the caption explicitly expresses at least one specific morphological observation in the report, including faithful paraphrases. Do not require the entire report to be covered. Do not split the report into findings or output explanations. Respect polarity, uncertainty, degree, location and scope. A negated finding cannot match a positive finding; a tentative caption cannot establish a definite finding. A specific normal or negative morphological observation can match the same observation.

same observation. Organ names, generic tissue/cell mentions and shared diagnostic names alone do not match. Ignore diagnoses, diagnostic impressions, differentials, formal grades, recommendations and non-microscopic metadata even when embedded in microscopic findings. Never infer morphology from a diagnosis. Missing or unassessable observations do not count as evidence. If no explicit morphological match is supported, return {"matched": false}.

For each k∈Ek \in\mathcal{E}, let πkv\pi_k^v be the normalized distribution over the valid visual tokens of the first frame xbkx_{b_k}, and πkt\pi_k^t the uniform distribution over the description-body tokens of dkd_k. Both distributions are zero outside their corresponding token spans. When ∣E∣>0|\mathcal{E}| > 0, the target attention distribution for modality m∈{v,t}m \in\{v,t\} is

Pzm=1−ε∣E∣∑k∈Eπkm+εUm,(6)P_z^m = \frac{1-\varepsilon}{|\mathcal{E}|}\sum_{k\in\mathcal{E}}\pi_k^m+\varepsilon U^m, \tag*{(6)}

where the smoothing factor is ε=0.1\varepsilon= 0.1. The background distribution UvU^v is uniform over the valid visual tokens of all input frames, and UtU^t is uniform over the body tokens of all historical descriptions. Within a matched group, silent frames receive only the background target mass from εUv\varepsilon U^v and have no corresponding description-token span.

We sample positions uu at which diagnosis-body tokens are predicted. We use the corresponding attention queries from the 25th of 36 decoder layers (zero-based index 24). We obtain AumA_u^m by normalizing attention separately over the full visual and description domains and averaging over heads. The loss in Eq. (3) averages the model-to-target KL divergence over the sampled positions and the two modalities. Microscopic findings and matching labels supply training targets; inference uses the observed images and the model’s generated textual history.

Two-Stage Optimization

Stage 1 uses a peak learning rate of 10−410^{-4} and gives each supervised token equal weight through wr(1)=nr/(ng+nd+nz)w_r^{(1)} = n_r/(n_g+n_d+n_z), where nr=∣Ir∣n_r = |\mathcal{I}_r| for r∈{g,d,z}r \in\{g,d,z\}. Stage 2 continues from Stage 1 at 10−510^{-5} with fixed weights (wg(2),wd(2),wz(2))=(0.2,0.1,0.7)(w_g^{(2)},w_d^{(2)},w_z^{(2)})=(0.2,0.1,0.7). In both stages, we apply diagnostic attention supervision with λz=10−3\lambda_z=10^{-3} only when the training window contains at least one matched frame group.

In each stage, we train for up to two epochs with AdamW, a weight decay of 0.01, and an effective batch size of eight sessions. We clip the gradient norm to 1.0. The learning rate increases linearly over the first 5% of planned updates and then follows a cosine decay. We evaluate every 100 updates and at the end of each epoch. For each stage, we select the checkpoint with the lowest validation loss and stop early after three consecutive evaluations without a new minimum.

PathStreamBench Details

Evaluation Protocol

We evaluate released checkpoints or hosted API models with task-specific prompts and no additional training. For Tasks 1–3, models receive the same chronological frame sequence for each sample. General and pathology/medical VLMs retain the full observed history while it fits within the context window. Local implementations remove the oldest complete observation turns when necessary. Streaming baselines follow their native context-management policies. For Task 4, we first verified that each model produced complete answers, then defined a parsing rule for its output format to extract the selected option.

PathStream generates the first-frame description in response to an explicit request, so this frame receives description supervision only and bypasses the streaming gate at inference. For all models in Tasks 1–3, gate Macro-F1 is computed from the second frame onward.

Description scoring. For Task 2 and the description metrics of Task 3, ROUGE-L and CONCH are averaged over ground-truth response frames, including the first frame. Each generated description is compared only with the reference at the same frame; a missing response receives zero, and delayed responses are not matched to earlier references. Responses at ground-truth silent frames count as gate errors but do not enter the description-score average. Thus, the tendency to respond more frequently without gate supervision can slightly increase description scores while reducing gate Macro-F1.

Prompts and Conversation Format

We provide the PathStream prompts used for streaming supervision and Tasks 1–3, together with the output-format instructions for general and pathology/medical VLMs. In a complete PathStream session, the messages follow this order:

System prompt → first frame → description request → initial response → subsequent frames with response/silence decisions → final diagnostic request → diagnosis.

During training, annotated descriptions are supplied through teacher forcing; during inference, the model uses its own generated descriptions. The description request is sent once, immediately after the first frame. Frames at silent steps also contribute visual context. Tasks 1 and 2 end after the clip’s frame observations.

PathStream Prompts

System prompt. The following system prompt is used for streaming supervision and Tasks 1–3. The first line is included when organ/tissue metadata is available; {organ} is replaced by that metadata.

Organ/tissue: {organ}

You are a multimodal pathology assistant.

Description request for training and Task 3.

Observe the pathology views in their presented order. Briefly describe the morphology of each newly presented view in English. Remain silent while a similar view continues after your description. A finding may be described again in another view; do not restrict descriptions to facts absent from the entire history. Use the accumulated visual evidence to answer a diagnostic question when asked. Do not give a diagnosis during spontaneous morphological descriptions.

Description request for Task 1.

Observe the pathology views in their presented order. Briefly describe the morphology of each newly presented view in English. Describe the first frame. Remain silent while a similar view continues after your description. A finding may be described again in another view; do not restrict descriptions to facts absent from the entire history. Do not give a diagnosis.

Description request for Task 2.

Observe the pathology views in their presented order. Briefly describe the complete morphology of each newly presented view in English. Describe the first frame. Remain silent while a similar view continues after your description. A finding may be described again in another view; do not restrict descriptions to facts absent from the entire history. Do not give a diagnosis.

Final diagnostic request for training and Task 3.

The video stream has ended. Based on all the views observed so far, provide a concise English pathological diagnosis. Output only the diagnosis, without a heading, reasoning, or an evidence section. Preserve supported diagnostic uncertainty and subtype qualifiers; do not invent unsupported details.

Prompt Adaptation for General and Pathology/Medical VLMs

The general and pathology/medical VLMs use the sample’s system prompt and express frame decisions through generated text. A silent response is interpreted as silence; a morphological description is interpreted as an update and appended to the dialogue history. Silent responses add no assistant text to that history.

Task 1. The following instruction is appended to the PathStream Task 1 description request above:

If remaining silent, output exactly silent. Otherwise output the description directly, without an update label.

Task 2. The description request is:

Observe the pathology views in their presented order. For each frame, output either exactly the lowercase word silent, or directly a concise English description of the complete morphology of that view. Describe the first frame. Output silent only while a similar view continues after your description. A finding may be described again in another view; do not restrict descriptions to facts absent from the entire history. Do not add an update label, heading, reasoning, or a diagnosis. Do not give a final diagnosis.

Task 3. The description and diagnostic requests are the same as those shown for PathStream Task 3. The following output-format instruction is appended to the system prompt:

For each pathology frame, output either exactly the lowercase word silent, or directly a concise English morphological description of that frame. Describe the first frame. Output silent only while a similar view continues after your description. A finding may be described again in another view. Do not add an update label, heading, reasoning, or a diagnosis to a frame description. When the final diagnostic question arrives, answer it directly using all observed views; the silent option applies only to frame observations.

WSI Precision and WSI Relevance

Following WSI-LLaVA [11], we use WSI Precision and WSI Relevance to evaluate final diagnoses on WSI viewing trajectories and educational pathology videos. GPT-6-luna extracts and scores diagnostic claims from the diagnostic question, reference answer, and model prediction, all supplied as text. Claim extraction. Each diagnosis is split into distinct, non-overlapping claims about disease, subtype, differentiation, grade, invasion, negation, and certainty, using only explicitly stated information. Qualifiers stay with the disease they describe, preserving distinctions such as possible versus confirmed. Normal, benign, negative, and inconclusive diagnoses are retained when they are the diagnostic answer; repeated claims, management advice, and incidental background findings are excluded. Reference claims are extracted

once, independently of predictions, and reused across models. The same extraction rules apply to predicted claims.

Claim scoring. Each claim receives one of four scores: 1.0 for full support with clinically equivalent meaning; 0.7 for a minor difference that leaves the diagnostic meaning unchanged; 0.3 for partial agreement with an important diagnostic error or substantial vagueness; and 0.0 for an omitted, unsupported, unrelated, or fundamentally contradictory claim. Scores account for specificity, negation, and uncertainty, while equivalent terms and paraphrases receive full credit. The evaluator provides supporting or conflicting text and a brief reason for each score.

Metric calculation. WSI Precision measures reference coverage: each reference claim is scored against the complete generated diagnosis. WSI Relevance measures prediction support: each predicted claim is scored against the complete reference diagnosis. For a session with MM reference claims and KK predicted claims, let aja_j and bkb_k be their respective scores. We compute

WSI-P=1M∑j=1Maj,(7)\mathrm{WSI\text{-}P} = \frac{1}{M}\sum_{j=1}^{M} a_j, \tag*{(7)}
WSI-R=1K∑k=1Kbk.\mathrm{WSI\text{-}R} = \frac{1}{K}\sum_{k=1}^{K} b_k.

Omitted reference claims and unsupported predicted claims receive zero. Unsupported claims include more specific diagnoses or additional alternatives not established by the reference. WSI Relevance is zero when no diagnostic claims are generated. Missing, empty, or protocol-invalid model answers receive zero for both metrics.

We average the session scores with equal weight, regardless of the number of claims in each session. Both metrics range from 0 to 1; table values are the resulting averages multiplied by 100.

Task 1 Response–Silence Patterns

Task 1 includes five patterns. Below, U denotes a morphological response and S denotes silence, with one symbol per frame. Each example starts with a response to the first frame.

Continuous updates. UUUU: each successive frame presents a visually distinct view, so the model responds at every step. Sustained silence. USSS: the frames remain visually similar, so the model describes the first frame and stays silent for the next three. Stop after a burst. UUUSS: the first three frames present changing morphology, followed by two frames similar to the third. The model responds three times, then remains silent. Restart after silence. USSU: the model responds to the first frame, stays silent during two similar frames, and responds again when the fourth frame presents a visually distinct view. Repeated switching. USUSU: each new view is followed by a similar frame before another visual change, producing repeated switches between response and silence.

Full Benchmark Results

Domain SFT narrows the gaps in response timing and morphological description within complete diagnostic sessions,

while diagnostic synthesis remains a key advantage of PathStream (Table S2). In Task 3, Qwen3-VL-4B + SFT achieves 91.30 gate Macro-F1 and 52.30 description CONCH, approaching PathStream’s 92.44 and 54.22, respectively.

For domain SFT, we fine-tune LiveCC-7B-Instruct, MMDuet2, and Qwen3-VL-4B-Instruct on our training data. We freeze each model’s visual encoder and jointly train its vision–language connector and LLM LoRA adapters. Qwen3-VL-4B + SFT uses the same backbone as PathStream with standard token-level supervised fine-tuning.

Table S2 and Table S3 report full benchmark and ablation metrics. Gate Macro-F1 averages update and silent F1. Task 3 description ROUGE-L and CONCH measure the morphological descriptions generated during trajectory viewing. Diagnosis quality is reported using WSI Precision, WSI Relevance, and ROUGE-L F1 on trajectories and videos. All scores are multiplied by 100, with higher values indicating better performance.

Hyperparameter Ablations

We select the default loss weights and LoRA rank using the 400 trajectories in the validation split. We evaluate their effects on the test split using PathStream Stage 1 (r=128r = 128) as the reference. Loss-weight variants multiply the per-token cross-entropy weight of gate or diagnosis tokens by 5 or 10. LoRA-rank variants use r∈{64,32,16}r \in\{64, 32, 16\} with the scaling parameter fixed at α=256\alpha= 256. All variants follow the Stage 1 training procedure. Table S4 reports the full results across Tasks 1–4.

Table S4. Hyperparameter ablations of loss weights and LoRA rank. Loss-weight variants multiply the per-token cross-entropy weight of gate or diagnosis tokens relative to PathStream (Stage 1), which uses LoRA rank r=128r = 128. LoRA-rank variants use r∈{64,32,16}r \in\{64, 32, 16\}. Tasks 1 and 2 are shown above; Tasks 3 and 4 are shown below. Tasks 1, 2, and 4, and the gate and description metrics of Task 3, use trajectory inputs. Diagnosis metrics are WSI Precision (WSI-P), WSI Relevance (WSI-R), and ROUGE-L F1 for both video and trajectory inputs. All scores are multiplied by 100. Bold and underlined scores indicate the best and second-best reported results in each column.

ModelTask 1 Gate Macro-F1Task 2 Gate Macro-F1Task 2 Description ROUGE-LTask 2 Description CONCH
PathStream (Stage 1)94.6192.6528.2048.75
gate CE ×5\times5<u>94.88</u><u>92.69</u><u>25.91</u>46.26
gate CE ×10\times1095.1392.9025.3646.04
diagnosis CE ×5\times592.3691.7825.7146.27
diagnosis CE ×10\times1091.8792.1725.18<u>46.76</u>
LoRA rank r=64r = 6492.3590.2825.4745.86
LoRA rank r=32r = 3292.1389.9824.9845.21
LoRA rank r=16r = 1691.7489.5924.2444.39
ModelTask 3 Gate Macro-F1Task 3 Description ROUGE-LTask 3 Description CONCHTask 3 Video diagnosis WSI-PTask 3 Video diagnosis WSI-RTask 3 Video diagnosis ROUGE-L F1Task 3 Trajectory diagnosis WSI-PTask 3 Trajectory diagnosis WSI-RTask 3 Trajectory diagnosis ROUGE-L F1Task 4 QA Acc.
PathStream (Stage 1)<u>92.05</u>34.4253.28<u>38.07</u><u>39.08</u><u>38.62</u>66.0368.2268.3754.05
gate CE ×5\times591.9133.9652.1934.9836.0435.1860.5962.3663.5956.67
gate CE ×10\times1092.16<u>34.03</u>52.6534.7936.6135.5160.3561.0962.8456.19
diagnosis CE ×5\times591.6733.78<u>52.38</u>37.7938.3538.11<u>67.81</u><u>69.59</u><u>70.04</u>55.71
diagnosis CE ×10\times1091.9033.8552.4738.2040.1240.6569.0070.9272.5255.24
LoRA rank r=64r = 6489.7631.6150.3234.3735.1137.2361.8763.8966.4650.95
LoRA rank r=32r = 3289.4631.1149.6533.2233.8635.1660.2062.0563.9750.24
LoRA rank r=16r = 1689.0830.3548.7431.7232.2734.5958.1059.8561.7849.29

Table S4.

The default gate weight already supports strong response timing. Stage 1 achieves a Task 1 gate Macro-F1 of 94.61, and increasing the gate weight adds at most 0.52 points. This small gain suggests diminishing returns to stronger gate supervision once response timing is well learned. Higher gate weights also reduce Task 2 description quality and final diagnosis scores on both trajectories and videos. At ×10, trajectory WSI Precision and Relevance decrease by 5.68 and 7.13 points. The default gate weight thus supports learning response control while preserving description and diagnosis performance.

Higher diagnosis weights strengthen diagnostic learning. Increasing the diagnosis weight improves trajectory WSI Precision and Relevance by 1.78 and 1.37 points at ×5, and by 2.97 and 2.70 points at ×10, relative to Stage 1. This supports placing greater emphasis on diagnostic supervision. During Stage 1, however, the same setting lowers Task 1 gate Macro-F1 from 94.61 to 91.87 and reduces description scores.

Lower LoRA ranks reduce performance across tasks. Scores consistently decrease as the rank is reduced from 128 to 64, 32, and 16. At r=16r = 16, trajectory WSI Precision and Relevance fall by 7.93 and 8.37 points, respectively, whereas Task 1 gate Macro-F1 decreases by 2.87 points. These results support the default rank r=128r = 128 for streaming interaction and diagnostic synthesis.

Organ-Wise Benchmark Results

For each organ in Figure S2, we combine four task scores on a 0–100 scale. Task 1 uses gate Macro-F1. Task 2 averages ROUGE-L and CONCH for morphological descriptions, and Task 3 averages WSI Precision and WSI Relevance for trajectory diagnoses. Task 4 uses question-answering accuracy. Tasks 1–3 each contribute 30% of the overall score, and Task 4 contributes 10%.

Complete Qualitative Responses

Figure S3 presents the complete descriptions and final diagnoses corresponding to Figure 7, alongside the pathologist’s annotations.

Multi-Pathologist Case Study

We collected viewing trajectories from three pathologists examining the same colon WSI to study how PathStream supports different pathologist-led examinations. Each trajectory provides a distinct sequence of views for PathStream to describe and integrate into a final diagnosis. Figure S4 to Figure S6 show the three trajectories, selected intermediate responses, and the corresponding final diagnoses.

Clinical case study: pathologist 1

Figure S4. Clinical case study: pathologist 1. The viewing trajectory is overlaid on the colon WSI, with selected PathStream descriptions and its final diagnosis. Arrows indicate viewing direction; Start and End mark the session boundaries. Ellipses indicate excerpted responses.

Clinical case study: pathologist 3

Figure S6. Clinical case study: pathologist 3. A third trajectory on the same WSI yields another sequence of morphological descriptions while preserving agreement with the reference diagnosis on tumor type, differentiation, invasion extent, and vascular tumor thrombus.

Reference diagnosis. The pathologist-provided ground truth is: Adenocarcinoma, not otherwise specified, moderately differentiated, invasive through the full thickness of the intestinal wall into the pericolonic fibroadipose tissue, with vascular tumor thrombus.

Different trajectories elicit different descriptions. The pathologists visit different regions and revisit tissue in different orders. PathStream’s intermediate descriptions vary with the views encountered along each trajectory. For example, the first includes cribriform and papillary glands, luminal mucin, and glands extending through fibromuscular tissue. The second includes stromal hemorrhage, a broad smooth-muscle band, and luminal debris. The third includes dense fibrosis, lymphoplasmacytic inflammation, and small glandular nests in smooth muscle. These responses illustrate how PathStream follows the evidence encountered during each pathologist’s examination.

Different trajectories converge on the same diagnosis. Despite these differences in viewing order and intermediate descriptions, all three final outputs agree with the reference diagnosis on tumor type, differentiation, invasion through the bowel wall into pericolonic fibroadipose tissue, and vascular tumor thrombus. Their wording differs, but their diagnostic content is consistent. This case illustrates PathStream’s ability to adapt its ongoing assistance to different pathologist-led viewing trajectories while maintaining a consistent diagnostic conclusion, supporting its role as a streaming diagnostic copilot.

Clinical case study: pathologist 2

Figure S5. Clinical case study: pathologist 2. A second trajectory on the same WSI elicits different intermediate descriptions. PathStream reaches the same final diagnostic conclusion, consistent with the reference diagnosis.

References

  1. [1]Shuai Bai, Yuxuan Cai, Ruizhe Chen, Kevin Chen, Xionghui Chen, Zesen Cheng, Lianghao Deng, Wei Ding, Chang Gao, Chunjang Ge, Wenbin Ge, Zhifang Guo, Qidong Huang, Jie Huang, Fei Huang, Binyuan Hui, Shutong Jiang, Zhao-hai Li, Mingsheng Li, Mei Li, Kaixin Li, Zicheng Lin, Jun-yang Lin, Xuejing Liu, Jiawei Liu, Chenglong Liu, Yang Liu, Dayiheng Liu, Shixuan Liu, Dunjie Lu, Ruilin Luo, Chenxu Lv, Rui Men, Lingchen Meng, Xuancheng Ren, Xingzhang Ren, Sibo Song, Yuchong Sun, Jun Tang, Jianhong Tu, Jian-qiang Wan, Peng Wang, Pengfei Wang, Qiyuye Wang, Yuxuan Wang, Tianbao Xie, Yiheng Xu, Haiyang Xu, Jin Xu, Zhibo Yang, Mingkun Yang, Jianxin Yang, An Yang, Bowen Yu, Fei Zhang, Hang Zhang, Xi Zhang, Bo Zheng, Humen Zhong, Jingren Zhou, Fan Zhou, Jing Zhou, Yuanzhi Zhu, and Ke Zhu. Qwen3-VL Technical Report, 2025. 5arxiv.org/abs/2511.21631
  2. [2]Souradeep Chakraborty, Ruoyu Xue, Rajarsi Gupta, Oksana Yaskiv, Constantin Friedman, Natallia Sheuka, Dana Perez, Paul Friedman, Won-Tak Choi, Waqas Mahmud, Beatrice Knudsen, Gregory Zelinsky, Joel Saltz, and Dimitris Samaras. Measuring and predicting where and when pathologists focus their visual attention while grading whole slide images of cancer. Medical Image Analysis, 107:103752, 2026. 2arxiv.org/abs/2508.01668
  3. [3]Joya Chen, Zhaoyang Lv, Shiwei Wu, Kevin Qinghong Lin, Chenan Song, Difei Gao, Jia-Wei Liu, Ziteng Gao, Dong-xing Mao, and Mike Zheng Shou. VideoLLM-online: Online Video Large Language Model for Streaming Video. In Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, pages 18407–18418, 2024. 2, 5arxiv.org/abs/2406.11816
  4. [4]Joya Chen, Ziyun Zeng, Yiqi Lin, Wei Li, Ziru Ma, and Mike Zheng Shou. LiveCC: Learning Video LLM with Streaming Speech Transcription at Scale. In Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, pages 29083–29095, 2025. 2, 5arxiv.org/abs/2504.16030
  5. [5]Richard J. Chen, Chengkuan Chen, Yicong Li, Tiffany Y. Chen, Andrew D. Trister, Rahul G. Krishnan, and Faisal Mahmood. Scaling Vision Transformers to Gigapixel Images via Hierarchical Self-Supervised Learning. In 2022 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), pages 16123–16134, New Orleans, LA, USA, 2022. IEEE. 2arxiv.org/abs/2206.02647
  6. [6]Tong Ding, Sophia J. Wagner, Andrew H. Song, Richard J. Chen, Ming Y. Lu, Andrew Zhang, Anurag J. Vaidya, Guillaume Jaume, Muhammad Shaban, Ahrong Kim, Drew F. K. Williamson, Harry Robertson, Bowen Chen, Cristina Almagro-Pérez, Paul Doucet, Sharifa Sahai, Chengkuan Chen, Christina S. Chen, Daisuke Komura, Akihiro Kawabe, Mieko Ochi, Shinya Sato, Tomoyuki Yokose, Yohei Miyagi, Shumpei Ishikawa, Georg Gerber, Tingying Peng, Long Phi Le, and Faisal Mahmood. A multimodal whole-slide foundation model for pathology. Nature Medicine, 31(11):3749–3761, 2025. 2DOI
  7. [7]Yiran Guan, Liang Yin, Dingkang Liang, Jianzhong Ju, Zhenbo Luo, Jian Luan, Yuliang Liu, and Xiang Bai. Video Streaming Thinking: VideoLLMs Can Watch and Think Simultaneously. In Computer Vision – ECCV 2026, pages 80–99. Springer Nature Switzerland, Cham, 2026. 2
  8. [8]Edward J. Hu, Yelong Shen, Phillip Wallis, Zeyuan Allen-Zhu, Yuanzhi Li, Shean Wang, Lu Wang, and Weizhu Chen. LoRA: Low-Rank Adaptation of Large Language Models. In ICLR 2022, 2022. 5arxiv.org/abs/2106.09685
  9. [9]Ruina Hu, Chen Wang, Lai Wei, Jiongbao Bai, Bin Yu, Weiran Huang, Kai Wang, and Yue Wang. Attend to Evidence: Evidence-Anchored Spatial Attention Supervision for Multimodal RLVR, 2026. 5arxiv.org/abs/2605.30912
  10. [10]Maximilian Ilse, Jakub Tomczak, and Max Welling. Attention-based Deep Multiple Instance Learning. In Proceedings of the 35th International Conference on Machine Learning, pages 2127–2136. PMLR, 2018. 2
  11. [11]Yuci Liang, Xinsheng Lyu, Wenting Chen, Meidan Ding, Jipeng Zhang, Xiangjian He, Song Wu, Xiaohan Xing, Sen Yang, Xiyue Wang, and Linlin Shen. WSI-LLaVA: A Multimodal Large Language Model for Whole Slide Image. In Proceedings of the IEEE/CVF International Conference on Computer Vision, pages 22718–22727, 2025. 2, 6, 15arxiv.org/abs/2412.02141
  12. [12]Chin-Yew Lin. ROUGE: A Package for Automatic Evaluation of Summaries. In Text Summarization Branches Out, pages 74–81, Barcelona, Spain, 2004. Association for Computational Linguistics. 6
  13. [13]Junming Lin, Zheng Fang, Chi Chen, Haoxuan Cheng, Zihao Wan, Fuwen Luo, Ziyue Wang, Peng Li, Yang Liu, and Maosong Sun. Streamingbench: Assessing the Gap for MLLMs to Achieve Streaming Video Understanding. In ICASSP 2026 - 2026 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), pages 12147–12151, Barcelona, Spain, 2026. IEEE. 2arxiv.org/abs/2411.03628
  14. [14]Ming Y. Lu, Drew F. K. Williamson, Tiffany Y. Chen, Richard J. Chen, Matteo Barbieri, and Faisal Mahmood. Data-efficient and weakly supervised computational pathology on whole-slide images. Nature Biomedical Engineering, 5(6):555–570, 2021. 1, 2DOI
  15. [15]Ming Y. Lu, Bowen Chen, Drew F. K. Williamson, Richard J. Chen, Ivy Liang, Tong Ding, Guillaume Jaume, Igor Odintsov, Long Phi Le, Georg Gerber, Anil V. Parwani, Andrew Zhang, and Faisal Mahmood. A visual-language foundation model for computational pathology. Nature Medicine, 30(3):863–874, 2024. 2, 6DOI
  16. [16]Ming Y. Lu, Bowen Chen, Drew F. K. Williamson, Richard J. Chen, Melissa Zhao, Aaron K. Chow, Kenji Ikemura, Ahrong Kim, Dimitra Pouli, Ankur Patel, Amr Soliman, Chengkuan Chen, Tong Ding, Judy J. Wang, Georg Gerber, Ivy Liang, Long Phi Le, Anil V. Parwani, Luca E. Weishaupt, and Faisal Mahmood. A multimodal generative AI copilot for human pathology. Nature, 634(8033):466–473, 2024. 1, 2DOI
  17. [17]Xudong Lu, Yang Bo, Jinping Chen, Shuhan Li, Xintong Guo, Huankang Guan, Fang Liu, Dunyuan Xu, Peiwen Sun, Heyang Sun, Rui Liu, and Hongsheng Li. AURA: Always-On Understanding and Real-Time Assistance via Video Streams, 2026. 5arxiv.org/abs/2604.04184
  18. [18]Tianhang Nan, Song Zheng, Siyuan Qiao, Hao Quan, Xin Gao, Jun Niu, Bin Zheng, Chunfang Guo, Yue Zhang, Xiao-qin Wang, Liping Zhao, Ze Wu, Yaoxing Guo, Xingyu Li, Mingchen Zou, Shuangdi Ning, Yue Zhao, Wei Qian, Hong-duo Chen, Ruiqun Qi, Xinghua Gao, and Xiaoyu Cui. Deep learning quantifies pathologists’ visual patterns for whole slide image diagnosis. Nature Communications, 16(1):5493, 2025. 2, 3DOI
  19. [19]Junbo Niu, Yifei Li, Ziyang Miao, Chunjiang Ge, Yuanhang Zhou, Qihao He, Xiaoyi Dong, Haodong Duan, Shuangrui Ding, Rui Qian, Pan Zhang, Yuhang Zang, Yuhang Cao, Conghui He, and Jiaqi Wang. OYOV-Bench: How Far is Your Video-LLMs from Real-World Online Video Understanding? In Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, pages 18902–18913, 2025. 2arxiv.org/abs/2501.05510
  20. [20]OpenAI. Introducing GPT-6 and Luna. https://openai.com/index/introducing-gpt-6-sol-and-luna/, 2026. 5
  21. [21]Rui Qian, Shuangrui Ding, Xiaoyi Dong, Pan Zhang, Yuhang Zang, Yuhang Cao, Dahua Lin, and Jiaqi Wang. Dispider: Enabling Video LLMs with Active Real-Time Interaction via Disentangled Perception, Decision, and Reaction. In 2025 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), pages 24045–24055, 2025. 2arxiv.org/abs/2501.03218
  22. [22]Qwen Team. Qwen3.8-flash - Alibaba Cloud. https://www.alibabacloud.com/help/en/model-studio/qwen3-8-flash, 2026. 5
  23. [23]Mehmet Saygin Seyfioglu, Wisdom O. Ikezegwo, Fatemeh Ghezloo, Ranjay Krishna, and Linda Shapiro. Quilt-LLaVA: Visual Instruction Tuning by Extracting Localized Narratives from Open-Source Histopathology Videos. In Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, pages 13183–13192, 2024. 1, 2arxiv.org/abs/2312.04746
  24. [24]Zhuchen Shao, Hao Bian, Yang Chen, Yifeng Wang, Jian Zhang, Xiangyang Ji, and yongbing zhang. TransMIL: Transformer based Correlated Multiple Instance Learning for Whole Slide Image Classification. In Advances in Neural Information Processing Systems, pages 2136–2147. Curran Associates, Inc., 2021. 1, 2arxiv.org/abs/2106.00908
  25. [25]YUXUAN SUN, Yixuan Si, Chenglu Zhu, Kai Zhang, Zhongyi Shui, Bowen Ding, Tao Lin, and Lin Yang. CPathAgent: An Agent-based Foundation Model for Interpretable High-Resolution Pathology Image Analysis Mimicking Pathologists’ Diagnostic Logic. In Advances in Neural Information Processing Systems, pages 101673–101731. Curran Associates, Inc., 2025. 1, 2arxiv.org/abs/2505.20510
  26. [26]Qwen Team. Qwen3.6-35B-A3B: Agentic Coding Power, Now Open to All. https://qwenlm.github.io/blog/qwen3.6-35b-a3b/, 2026. 5
  27. [27]The Cancer Genome Atlas Research Network, John N Weinstein, Eric A Collisson, Gordon B Mills, Kenna R Mills Shaw, Brad A Ozenberger, Kyle Ellrott, Ilya Shmulevich, Chris Sander, and Joshua M Stuart. The Cancer Genome Atlas Pan-Cancer analysis project. Nature Genetics, 45(10):1113–1120, 2013. 2DOI
  28. [28]Trinh T. L. Vuong and Jin Tae Kwak. VideoPath-LLaVA: Pathology Diagnostic Reasoning Through Video Instruction Tuning, 2025. 2, 4
  29. [29]Pengyu Wang, Chenkun Tan, Shaojun Zhou, Qirui Zhou, Yanxin Chen, Xingyang He, Huazheng Zeng, Jijun Cheng, Chenghao Wang, Xiaomeng Qian, Pengfei Wang, Zhan Huang, Shanqing Gao, Wei Huang, Longjun Cao, Wu Ran, Jie Liu, Changtai Zhu, Hongkai Wang, Yifan Tian, Chenghao Liu, Zhen Ye, Xinhao Wang, Botian Jiang, Guoguo Feng, Zhaoye Fei, Ruixiao Li, Mingshu Chen, Yang Gao, Qinyuan Cheng, Shimin Li, and Xipeng Qiu. MOSS-VL Technical Report, 2026. 5arxiv.org/abs/2608.15045
  30. [30]Sheng Wang, Ruiming Wu, Charles Herndon, Songhao Li, Yihang Liu, Shunsuke Koga, Xiaowei Xu, David E. Elder, Jonathan Alex Miles, Annie Jin, Ikuko Hirai, Meaghan Dougher, Jeanne Shen, and Zhi Huang. Pathology-CoT: Learning visual chain-of-thought agents from expert whole-slide image diagnosis behaviour. Nature Biomedical Engineering, 2026. 1, 2DOI
  31. [31]Sheng Wang, Jialu Yao, Maria V. Rossi, Shunsuke Koga, Esther Baranov, MacLean P. Nasrallah, Songhao Li, Jonathan Xu, Wei Du, Cindy McGrath, Timothy Chao, Anne Wang, Zhaohai Yang, Daniel Akuma, Seletom M. Walle, Olga Pozdnyakova, Edward B. Lee, Zahra Alipour, Annapurna Saksena, Rashmi Tondon, Nikolina Dioufa, David E. Elder, George J. Netto, Xiaowei Xu, and Zhi Huang. PathWork: Learning from real-world pathology practice to build AI copilots, 2026. 2arxiv.org/abs/2610.39441
  32. [32]Weiyun Wang, Zhangwei Gao, Lixin Gu, Hengjun Pu, Long Cui, Xingguang Wei, Zhaoyang Liu, Lingling Jing, Shenglong Ye, Jie Shao, Zhaokai Wang, Zhe Chen, Hongjie Zhang, Ganlin Yang, Haomin Wang, Qi Wei, Jinhui Yin, Wenhao Li, Erfei Cui, Guanzhou Chen, Zichen Ding, Changyao Tian, Zhenyu Wu, Jingjing Xie, Zehao Li, Bowen Yang, Yuchen Duan, Xuehui Wang, Zhi Hou, Haoran Hao, Tianyi Zhang, Songze Li, Xiangyu Zhao, Haodong Duan, Nianchen Deng, Bin Fu, Yinan He, Yi Wang, Conghui He, Botian Shi, Junjun He, Yingtong Xiong, Han Lv, Lijun Wu, Wenqi Shao, Kaipeng Zhang, Huipeng Deng, Biqing Qi, Jiaye Ge, Qipeng Guo, Wenwei Zhang, Songyang Zhang, Maosong Cao, Junyao Lin, Kexian Tang, Jianfei Gao, Haian Huang, Yuzhe Gu, Chengqi Lyu, Huanze Tang, Rui Wang, Haijun Lv, Wanli Ouyang, Limin Wang, Min Dou, Xizhou Zhu, Tong Lu, Dahua Lin, Jifeng Dai, Weijie Su, Bowen Zhou, Kai Chen, Yu Qiao, Wenhai Wang, and Gen Luo. InternVL3.5: Advancing Open-Source Multimodal Models in Versatility, Reasoning, and Efficiency, 2025. 5arxiv.org/abs/2508.18265
  33. [33]Yueqian Wang, Songxiang Liu, Disong Wang, Nuo Xu, Guanglu Wan, Huishuai Zhang, and Dongyan Zhao. MMDuet2: Enhancing Proactive Interaction of Video MLLMs with Multi-Turn Reinforcement Learning. International Conference on Learning Representations, 2026:23257–23270, 2026. 2, 5arxiv.org/abs/2512.06810
  34. [34]Hanwen Xu, Naoto Usuyama, Jaspreet Bagga, Sheng Zhang, Rajesh Rao, Tristan Naumann, Cliff Wong, Zelalem Gero, Javier González, Yu Gu, Yanbo Xu, Mu Wei, Wenhui Wang, Shuming Ma, Furu Wei, Jianwei Yang, Chunyuon Li, Jianfeng Gao, Jaylen Rosemon, Tucker Bower, Soohee Lee, Roshanthi Weerasinghe, Bill J. Wright, Ari Robicsek, Brian Piening, Carlo Bufalo, Sheng Wang, and Houfeng Poon. A whole-slide foundation model for digital pathology from real-world data. Nature, 630(8015):181–188, 2024. 2DOI
  35. [35]Ruyi Xu, Guangxuan Xiao, Yukang Chen, Liuning He, Kelly Peng, Yao Lu, and Song Han. StreamingVLM: Real-Time Understanding for Infinite Video Streams. International Conference on Learning Representations, 2026:61463–61475, 2026. 2, 5arxiv.org/abs/2510.09608
  36. [36]Weiwen Xu, Hou Pong Chan, Long Li, Mahani Aljunied, Ruifeng Yuan, Jianyu Wang, Chenghao Xiao, Guizhen Chen, Chaoqun Liu, Zhaodonghui Li, Yu Sun, Junao Shen, Chaojun Wang, Can Hu, Siwei Pan, Jie Tan, Tingyang Xu, Deli Zhao, Hao Zhang, and Yu Rong. Lingshu: Generalist Foundation Model for Unified Multimodal Medical Understanding and Reasoning. IEEE Transactions on Pattern Analysis and Machine Intelligence, pages 1–18, 2026. 5
  37. [37]Haoji Zhang, Yiqin Wang, Yansong Tang, Yong Liu, Jiashi Feng, and Xiaojie Jin. Flash-Vstream: Efficient Real-Time Understanding for Long Video Streams. In 2025 IEEE/CVF International Conference on Computer Vision (ICCV), pages 21059–21069, 2025. 2arxiv.org/abs/2506.23825
  38. [38]Wenchuan Zhang, Penghao Zhang, Jingru Guo, Tao Cheng, Jie Chen, Shuwan Zhang, Zhang Zhang, Yuhao Yi, and Hong Bu. Patho-R1: A Multimodal Reinforcement Learning-Based Pathology Expert Reasoner. Proceedings of the AAAI Conference on Artificial Intelligence, 40(33):28418–28426, 2026. 2, 5

Paper details

vlnc:W_8zmnbmzw
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Computer Science

Not recorded for this paper

View statement
Looking for related papers…
Contents