WorksPhysics and Astronomy
Plasma transport by carrier electrons: delocalization length for heat-flux
Abstract
The delocalization length is an improved heat-flux non-locality metric accounting for the localizing effect of electron-electron collisions on the electron population carrying heat-flux. Magnetization also localizes the carrier electrons; the delocalization Hall parameter shows that this occurs at a faster rate than magnetization of thermal conductivity (). The traditional Knudsen number, which uses the electron-ion mean-free path, does not fairly represent non-locality across ionization and magnetization; should instead be used. The kinetic understanding of the three magnetized heat-flux components is unified in the linear regime with a full electron-electron collision operator and a converged harmonic expansion of the electron distribution (up to ). Righi-Leduc heat-flux is found to delocalize easier than its perpendicular counterpart, due to its carriers being higher energy electrons. This approach lays the groundwork for a consistent treatment of the kinetically-modified induction equation.
Classical theory describes fluxes of electron energy in a ’local’ plasma through the transport coefficients1–6. A temperature gradient is assumed to not affect the isotropic distribution of electrons, only driving an anisotropic component responsible for the heat-flux. As temperature gradients become steeper, is also perturbed. The metric typically used to assess this effect is the Knudsen number:
where is the temperature length-scale and is the mean free path between electron-ion (e-i) collisions.
If an electron travels further between collisions than the temperature length-scale (), it is ’non-local’. As the high energy electrons have longer mean free paths (scaling as the 4th power of the electron velocity ), they leave the region of interest. The high-energy tail of the electron distribution, which contributes most to heat-flux, is depleted. Therefore, the heat-flux is lower than classical predictions; a flux-limiter is used in hydrodynamics codes as an attempt to account for this reduction7.
This paper focuses on use of the e-i mean free path in equation 1; for low- plasmas this length should be lowered due to electron-electron (e-e) collisions8–13. Using as an input to flux-limiters will therefore not consistently suppress different plasma species. For this purpose, a delocalization length is measured from kinetic simulations, as well as the rate of suppression.
Then there is the question of magnetic fields. While some experiments purposefully apply these fields14,15, they are also spontaneously generated and are increasingly considered ubiquitous to plasma physics experiments16–19. Magnetization results in thermal conduction becoming anisotropic:
with unrestricted heat-flow along magnetic field lines () and restricted heat-flow perpendicular () as the Hall parameter (a measure of magnetization) increases2,3. The term is Righi-Leduc heat-flow, which can be conceptualized as thermal conduction being rotated by the magnetic field. Note that is the electron collision time defined by Braginskii2.
How is the delocalization length modified by magnetization? Are all components suppressed the same? And how does this affect how magnetohydrodynamic (MHD) codes should flux-limit the different components of magnetized heat-flow?
The answer to these questions is sought in the regime of marginal non-locality, where corrections to classical transport begin to emerge. This is the foundation for future work extending into deep non-locality.
The approach taken is through the lens of carrier electrons: studying the electron population responsible for carrying heat-flux. This concept was developed to explain the behavior of the classical transport coefficients6 (the previous paper in the series). A review of the important findings applicable to the transition into non-locality are included in section I.
Section II walks through transport theory by outlining a hierarchy of length-scales responsible for classical and kinetic plasmas. Section III presents the Vlasov Fokker-Planck (VFP) simulation methodology, including an introduction to VFP theory. The simulations are considered ’state of the art’ (harmonic expansion up to , full e-e collision operator20), and are applied to the most fundamental kinetic problem: 1D linear temperature perturbations.
Sections IV and V first demonstrate how e-e collisions and magnetization affect the susceptibility of a plasma to kinetic effects. They then fit the unmagnetized and magnetized delocalization lengths to a database of linear-mode calculations, which were validated against full VFP simulations; this database spans ionization, magnetization and degree of non-locality. The results are summarized in table I. The suppression factors for parallel, perpendicular and Righi-Leduc heat-flux are shown to compare favorably with the full VFP simulations. § 9 then applies these new lengths to a magnetized heat-flow flux limiter, for implementation into MHD codes.
Appendix A demonstrates the importance of a suitable collision operator for these calculations. Appendix B discusses the regime of applicability of these results. Convergence of the harmonic expansion up to is demonstrated in appendix B § 13.1. The superposition of multiple linear modes are shown to hold in appendix B § 13.2. Appendix C describes the linear mode solver. Appendix D extends the fit for the heat-flow classical carrier velocity6 into the kinetic regime.
Carrier electrons for classical transport
A ’typical’ electron in a classical plasma travels at the thermal velocity . However, these are not the electrons responsible for carrying the heat-flux. For an unmagnetized Lorentz plasma () the carrier-averaged velocity for heat-flux is . e-e collisions (at finite ) act to lower the thermal conductivity, as well as reduce the carrier velocity to for 6.
The carrier population also depends on magnetization. Magnetization can be quantified per electron velocity as:
where is the cyclotron frequency, is the e-i collision frequency and is the bulk Hall parameter typically used to quantify magnetization2,4,5.
corresponds to electrons at velocities of or greater being magnetized. However, as the heat-flux carrier electrons are at velocities much greater than this, does not fairly represent thermal conductivity magnetization. In fact, due to e-e collisions, low plasmas are harder to magnetize than high . For , ; this falls to 0.048 for .
To this end, a carrier Hall parameter for thermal conductivity was defined6:
where corresponds to 50% thermal conductivity suppression, independent of plasma ionization .
The preceding work took this approach for all the classical transport processes (e.g. thermal conduction, Nernst advection, or resistive diffusion of magnetic fields)6. Each process is carried by a different carrier population, and therefore requires a different carrier Hall parameter to fairly represent magnetization.
That work also calculated how the classical carrier velocities change with e-e collisions () and magnetization (). This dependence is plotted in Figure 1 for (a) and (b) . Magnetization lowers the carrier velocity to for and 2.17 for , independent of ionization.
Figure 1. Average electron velocity that carries perpendicular heat-flow (a) and Righi-Leduc (b) for a classical plasma. The y-axis is the carrier Hall parameter from equation (4). The x-axis is plasma ionization. Both magnetization and e-e collisions lower the energy of electrons responsible for heat-flux.
What can we learn about kinetic heat-flux from this classical carrier approach? The high velocity electrons responsible for kinetic effects are less collisional than the bulk. Any process that lowers the carrier velocity (e-e collisions and magnetization) will therefore make a plasma more localized. The carrier velocity for Righi-Leduc () was also found to be greater than perpendicular heat-flow (); it is therefore expected to be more susceptible to kinetic suppression.
| Unmagnetized -dependence | Carrier Hall parameter | Magnetized | |
| Classical heat-flow6 | |||
| — | peaks at | ||
| Delocalization length | |||
Table 1. Summary of parameters for classical (top) and kinetic (bottom) heat-flux. The first column is the ionization dependence of unmagnetized heat-flow and delocalization lengths. The second column is the magnetization metric for these processes, which applies for all . The final column is how the process is suppressed by magnetization.
Kinetic transport as a hierarchy of length scales
Unmagnetized length scales
When an electron collides with an ion, its energy remains unchanged due to the large mass ratio (). Instead, the electrons are elastically scattered such that they lose directionality. The electron-ion mean free path
can be conceptualized as the distance an electron travels before ion scattering makes it forget where it was originally going. After deflection it is still carrying its energy, only in a different direction. has been kept in this relation to emphasize how the faster electrons within the population have longer paths between scattering events than the slower electrons.
Thermal conductivity is governed by how far an electron travels before losing its directionality due to both electrons and ions, . A Lorentzian () plasma has an analytic classical thermal conductivity 1, which is then lowered by e-e collisions6. can be found by writing the unmagnetized heat-flow as 6.
i.e. in a Lorentzian plasma the heat carriers travel a distance between deflections, an order of magnitude further than a thermal electron due to the carrier population living at .
A plasma is classical if an electron loses its energy within a distance that is short compared with the temperature length-scale . Only e-e collisions result in electrons losing their energy. The resultant path length is:
Where the factor of comes from the relative collision frequency. This is the distance an electron moves, not accounting for the fact that it is redirected numerous times in the process. The net displacement before an electron loses its energy is a random walk of ,
Luciani et al.8,11 took the total directionality step as , which assumes that for the electrons halve the length8. This gives .
Epperlein & Short assumed (using their values for ). Walsh & Sherlock adopted the same form for kinetic suppression of heat-flux12.
This work measures the delocalization length relevant for heat-flow from the kinetic response computed with the full electron-electron collision operator:
Magnetization length-scale
An electron in a magnetic field no longer travels in straight lines across the field between collisions; it is confined to a Larmor radius , where the subscript denotes velocity perpendicular to the magnetic field. The magnetic field does no work on the electron, but it does confine the mean free path between collisions. Writing this per electron velocity21:
Figure 2. Classical (dotted) and kinetic (solid) heat-flux moment against electron velocity for (black) and (orange). For a non-locality level of does not affect the thermal conductivity. For , reduces the magnitude and shifts the carrier electrons to slower velocity, despite this seemingly being a lower level of non-locality. This motivates using a delocalization length rather than .
With Braginskii’s Hall parameter and , the Hall parameter is ; this is a comparison of unmagnetized e-i scattering length to the Larmor radius. However, it does not include the e-e collision contribution.
The preceding work defined the carrier Hall parameter for thermal conductivity (equation 4)6. Writing gives the classical scattering length of the heat-carrying electrons:
where .
This paper finds delocalization to be magnetized at a different rate to the classical conductivity. The magnetized delocalization length is measured in this paper:
Where is the delocalization Hall parameter:
is defined such that magnetization halves the delocalization length, which is the same convention as halving .
The delocalization scattering length is then:
Note the differences between the classical scattering length of equation 10 and the delocalization scattering length in equation 13. The non-locality of the electron population is magnetized at lower magnetic field strengths than the thermal conductivity.
has a magnetization dependence of , which is lower than the exponent 2 predicted by the per-velocity form in equation 9. This is due to the feedback of magnetization itself lowering the carrier velocity (as shown in Figure 1) thereby making the plasma harder to further magnetize. This is discussed in more detail in previous work looking to explain the dependence of 6.
Righi-Leduc was shown in Figure 1 to be carried by faster electrons than the perpendicular heat-flow. It therefore requires its own delocalization length:
However, it is found to have the same dependence on delocalization magnetization as the perpendicular thermal conductivity:
Righi-Leduc is therefore more susceptible to non-locality than perpendicular heat-flow, but is relocalized by magnetization at the same rate.
VFP SIMULATIONS
The Vlasov–Fokker–Planck code K2{sup}22–24` is used to generate data at varying levels of non-locality. The setup used here is one dimensional with frozen ions and a fixed uniform magnetic field strength.
The electron velocity distribution is expanded in spherical harmonics and truncated at , leaving the , , , , , and system of equations. This expansion separates the electron speeds from their direction. The most important harmonics for this work are and .
is the isotropic electron distribution: how many electrons have a speed regardless of their direction, with being centered at zero in rest frame. carries information about the electron density () and temperature/energy (). is the directional imbalance: if more electrons at a given are travelling in than then is positive. is a vector holding directional information such as current () and heat-flow ().
Neither nor higher harmonics contributes to the density, temperature, current or heat-flow; they enter only indirectly through their feedback on . Because is itself of order relative to , that feedback is second order, and the classical transport coefficients are recovered exactly at any truncation. The effect of truncation is therefore purely non-local, vanishing in the local limit and growing with non-locality. Appendix B1 demonstrates the convergence of expansion up to and the importance of and to the suppression factors calculated in this paper.
Figure 3. Unmagnetized heat-flow suppression () against non-locality metric () for each candidate non-locality length-scale . The black lines in panels (a)–(c) is fit to that panel’s VFP data, with the RMS error given at the top; in (d) it is (equation (16)). Cases: a) electron-ion mean free path. b) LMV 19838 . c) ES 19919 . d) this work .
Further discussion of the validated range of this paper can be found in appendix B. Linearity is shown to hold through demonstration of superposition in appendix B 2.
Collisions
The ions are assumed to be stationary and infinitely massive relative to the electrons, such that electron–ion collisions randomize the electron direction but leaves the speed unchanged. Therefore, e-i collisions do not affect . Instead e-i collisions act to damp , the directional preference of the electrons. This happens at a rate and is trivial to include in VFP simulations, since the ions affect each electron velocity independent of the other electron velocities. With no e-e collisions the mean free path then scales as .
The electron–electron collision operator is more complex, for two reasons. First, it acts on both and . Second, it results in electrons of one velocity depending on electrons at a different velocity (which shows up computationally as derivatives in velocity space). This complexity is often avoided in VFP codes by using a rescaled e-i collision frequency presented by Epperlein & Short 9,11,23,25,26.
While this rescaling can reproduce the classical thermal conductivity9 it does not reproduce the electron distribution of a more detailed collision operator. While the Epperlein & Short approximation at gives an effective collision frequency of across all electron velocities, the full collision operator in local conditions gives and , rising with electron velocity. Appendix A demonstrates in more detail how an effective collision frequency does not reproduce the change in electron carrier velocity required for evaluating non-locality.
This paper retains the full electron–electron collision operator20, which acts on all harmonics. is relaxed to Maxwellian through two e-e collision terms: velocity-space diffusion and drag from slower electrons. The e-e collisions on move the energy between the electron population.
e-e collisions acting on governs the exchange of momentum in the population. Two types of terms are present: the ’test particle’ terms reacting to the background ( acting on ), and the ’field particle’ terms ( acting on ). The test particle terms include pitch-angle scattering as well as drag and diffusion on the anisotropy; alone they do not conserve electron momentum. The field particle terms then restore this parity by including the reaction of the background to the test particle.
The complete operator used here conserves momentum to of the electron–ion drag and recovers to within 1.6% of Epperlein & Haines3 and 0.2% of Sadler-Walsh-Li4, with recovered to within 4% across –100, comparable to the quoted accuracy of the fits themselves.
VFP Database
Each run is initialized with a temperature perturbation of the form at uniform density. is the perturbation wavenumber, where is the distance between perturbation peaks. This follows the standard Epperlein & Short test problem9. The nominal temperature perturbation used was , although runs were done spanning (see figure 8). The perturbation amplitude is chosen small enough that the response is linear; this is verified in section B 2 as well as figure 8.
Transport coefficients are extracted instantaneously at the location of maximum . The kinetic suppression factors are then formed by dividing each measured coefficient by the local coefficient evaluated at the same and . The local coefficients are re-calculated here to avoid interpolation errors on the published fits3,4; they are found to agree within the stated 4% accuracy.
The distribution function is discretized on a uniform grid in and , with spatial cells and velocity cells spanning . Velocity-space resolution requirements are set by the carrier velocities: since transport is dominated by electrons at several times
Figure 4. Impact of e-e collisions on different length-scales from section II. is the thermal conductivity scattering length, which is least affected by ionization . The ratio of to the Larmor radius sets the carrier Hall parameter for thermal conductivity. The delocalization length is the net distance an electron travels before losing its energy, which can be compared with to assess non-locality. is then compared with the Larmor radius to assess how magnetization re-localizes the plasma.
, the grid must resolve the distribution well beyond the thermal peak, and must be chosen large enough
Figure 5. Classical (dotted) and kinetic (solid) heat-flux moment for against electron velocity for (dark purple) and (lime green). Both kinetic simulations used . The heat-carrying electrons at are heavily affected by kinetics, lowering the magnitude and lowering the carrier velocity. is much more robust to non-local effects. This motivates extending the delocalization length to the magnetized regime.
that the transport integrals are converged rather than truncated. Grid convergence was tested, with shifting the kinetic suppression of thermal conductivity by less than 2% and by under 0.6%, both below the 3% accuracy of the classical transport coefficients3.
While the 1D VFP simulations are taken as the ’absolute truth’ for the plasma transport response to non-locality, these are not the data points used to fit the constants in this paper. Instead, a linear mode solver was validated against the full VFP simulations, and then used to generate a dense database of heat-flux suppression across , and . This allowed for the 299 1D VFP datapoints to be extended to 118,041 datapoints at higher resolution (), which improves the accuracy of the fits provided. The fits are compared against the 1D VFP simulations in all the figures of this paper, still showing excellent agreement. More explanation of the linear mode solver can be found in appendix C.
Unmagnetized Kinetic Heat-Flow
Section I demonstrated that plasma ionization changes the susceptibility of heat-flow to non-locality through e-e collisions; the heat-carrying electrons are shifted to lower in low- plasmas. However, the simulations used in that demonstration were classical in nature.
Figure 2 shows the unmagnetized heat-flux moment normalized to the classical conductivity for 2 values of . The local equivalents are shown as dotted lines. The plasma uses , where is the temperature perturbation wavenumber (large means short perturbation wavelength). The high energy electrons carrying the flux are suppressed, which is often called tail depletion. The magnitude is lowered, such that . The carrier velocity is also lowered (seen by the shift to the left).
Figure 2 also plots for a seemingly larger level of non-locality . However, in this case the anisotropic electron distribution is hardly affected by the non-locality with . The discrepancy demonstrates why using is not sufficient for parameterizing non-locality. A delocalization length that represents all ionizations is sought.
Three length-scales from the literature are now tested against a suite of unmagnetized VFP data: 75 data points spanning 8 values of and a range of (through changing the temperature perturbation wavelength). Each point is paired against a classical reference point in order to calculate the heat-flow suppression , which spans 0.268–0.987. Note that the perturbation amplitude in this scan is kept constant at 1%; this does not affect the results while in the linear regime, as discussed in section VI.
The first candidate length-scale of interest is the electron–ion mean free path ; this is the typical length used to assess non-locality. Figure 3(a) plots the simulated thermal conductivity suppression against . The dependence on is substantial, with one case at being essentially unsuppressed, while the equivalent case at has . A Knudsen number constructed with just the e-i mean free path therefore over-predicts suppression for low- plasmas while under-predicting suppression for high- plasmas.
Figure 3(b) and (c) then use lengthscales from LMV 19838 and Epperlein & Short 19919 respectively. The latter case is utilized in the work of Walsh & Sherlock 202412. The length scales progressively improve from figure 3(a) to (b) to (c), but there remains a small systematic dependence on plasma ionization.
Fitting the linear-mode database gives . This is 12% shorter at than the length given by Epperlein & Short27, which is consistent with the 13% expectation from the lowering of the carrier velocity with a full e-e collision operator (see appendix A).
The kinetic heat-flow suppression is then:
The constants and are fitted to the same database. is the wavenumber of the temperature perturbation applied, with being the periodic box length.
The held-out VFP simulations are reproduced to an RMS of 0.0024 in (figure 3(d)).
Figure 4 plots the length-scales from section II against ionization. Of importance here are and . The former is the distance that a heat-carrying electron travels before losing its directionality; this sets the classical thermal conductivity. The delocalization length is the net distance an electron travels before losing its energy; this can be compared with the temperature length-scale to assess the impact of kinetics on transport. All of the length-scales deviate greatly from the e-i mean free path .
Magnetized Kinetic Heat-Flow
Here is extended into the magnetized regime for heat-flow perpendicular to a magnetic field. This is motivated by figure 5, which plots the perpendicular heat-flux moment normalized to its classical counterpart for . The solid lines use at (black) and (green), while the dotted lines are the classical equivalents. As both values of use , they have the same delocalization length (); the results in section IV suggest that they should be affected the same by non-locality. Figure 5 clearly shows the distribution being more robust to kinetics, with compared with 0.52 for . The delocalization length perpendicular to the magnetic field is not the same as that parallel to the field.
To find the magnetized delocalization length , the linear-mode database is extended to –. 224 VFP simulations across 4 values of (1, 4, 15, 50), 8 values of (0.01-1.0) and a range of are held out for validation. The fitted delocalization Hall parameter is:
where the prefactor 13.5 is chosen such that corresponds to the delocalization length being 50% of its unmagnetized value.
The magnetized delocalization length then becomes:
Figure 6 shows the observed suppression of for all 224 magnetized datapoints against . All and dependence has been removed by the rescaling. The same suppression scaling from equation 16 is applied, using rather than :
Despite using the same function as unmagnetized, the VFP simulations collapse to an RMS of 0.011 for (filled symbols) and 0.018 for and 1 (open symbols), although many of the latter are essentially unaffected by kinetic suppression.
It’s worth dwelling on the difference between the carrier Hall parameter for thermal conductivity and the delocalization Hall parameter . The former comes from asking: ’are the classical electrons carrying heat magnetized?’. The latter comes from posing the question: ’are the non-local electrons responsible for kinetic suppression magnetized?’ Since the ’kinetic electrons’ are all of the fastest heat carriers, it is no surprise that they magnetize more easily than the bulk of the heat carriers.
Kinetic Righi-Leduc
Figure 1 showed that Righi-Leduc is carried by higher velocity electrons than perpendicular heat-flow. It is therefore expected that Righi-Leduc requires its own delocalization length .
This is borne out, with the kinetic Righi-Leduc coefficient measured through the moment, i.e. the anisotropy of the electron distribution perpendicular to both the temperature gradient and the magnetic field. The length-scale in the unmagnetized limit becomes:
For ; for .
Unlike the classical coefficients, the delocalization Hall parameter is the same as for perpendicular heat-flow:
Figure 6. Kinetic suppression of perpendicular heat-flow across four ionizations and eight magnetizations (-1), plotted against . The solid line is from equation 16, with and from table I. Filled symbols are 168 simulations at ; open symbols are the 56 runs at and . All datapoints shown here were held out of the fits.
It was expected that the faster Righi-Leduc carriers were more easily relocalized by magnetization, but this is not borne out: the difference between the two components lies entirely in the unmagnetized length. Note that in a kinetic database generated with harmonic truncation at , the Righi-Leduc delocalization Hall parameter was that of the perpendicular heat-flux. A plausible explanation is that the higher harmonics act as an additional velocity-dependent damping of that grows with ; this most strongly reduces the effective Hall parameter of the fastest electrons, offsetting the greater magnetizability of the Righi-Leduc carriers that an truncation suggests.
While results in kinetic Righi-Leduc being independent of and magnetization, the suppression follows a different shape to (equation 16). Figure 7(a) plots the kinetic Righi-Leduc coefficient normalized to its classical counterpart () for the magnetized VFP database; these are the same simulations as figure 6 except analyzing the moment rather than . is shown to over-suppress at low non-locality and under-suppress at high non-locality. A separate suppression function is fitted against the data using the same form as equation 16:
with and and RMS error of 0.019. Figure 7(b) compares and across at for various magnetizations; Righi-Leduc is consistently more suppressed by kinetics than its perpendicular counterpart.
Figure 7. (a): Kinetic Righi-Leduc coefficient normalized to its classical value across the magnetized VFP. Using the curve fitted to the perpendicular suppression with the Righi-Leduc delocalization length () over-suppresses at low non-locality and undersuppresses at high non-locality. Therefore a separate suppression curve for Righi-Leduc is fitted (equation 22). (b): and against for and a range of magnetizations .
Figure 8. Unmagnetized heat-flow suppression across a range of temperature perturbation amplitudes ( to ) viewed in 2 ways. (a) Uses the global scale (), allowing collapse onto one form. However, this is not practical for implementation into a hydrodynamics code, where each cell only knows local conditions. (b) Uses the local scale (), which then requires a tuned flux limiter to fit the data points, with the flux limiter value scaling linearly with .
Flux limiters
Since 1975 ’flux limiters’ have been a staple of plasma physics modeling2, restricting the electron heat-flow3 to a fraction of its free-streaming value. This is equivalent to placing the following limit on the thermal conductivity4,
where is the ’min’ flux limiter with typical values spanning . It is widely agreed that the value of is not fixed and should be ’tuned’ in an attempt to make radiation-hydrodynamics simulations better match laser-driven experiments28–31.
While the entire field would like to move beyond this crude approximation, VFP simulations are too computationally prohibitive for large-scale plasma physics experiments. Thermal flux limiters remain the norm. This section uses the findings of this paper to improve their use.
Global scale versus local scale
With excellent agreement between the suppression functions (, , ) and the VFP data shown in figures 3(d), 6, 7(a) one might assume kinetic suppression of conductivity to be ’solved’. This is not the case.
The results in this paper reproduce the linear kinetic response of heat-flux. The metric for non-locality is , where is the wavenumber of the perturbation and is the distance between sinusoidal temperature perturbation peaks. The as-built model therefore knows the perturbation global scale. This is unknown in a typical hydrodynamics code.
Thermal conduction is (most simply) calculated in a simulation cell by using at the cell faces; cells only know the temperature of their neighboring cells. The means of approximating kinetic suppression of heat-flow uses the temperature length-scale , which neither distinguishes between modes nor represents the global scale of individual modes. For a single mode the smallest temperature length-scale (which is at the location of peak heat-flux) is , where is the relative temperature perturbation amplitude.
Heat-flux suppression is independent of in the linear response, as long as the global scale () is known. Figure 8(a) shows the unmagnetized heat-flow suppression against for simulations with spanning 0.25%-8%; the results lay on top of one another, which is consistent with linear response.
If instead the global scale is unknown, the temperature length-scale at a particular location must be used. Figure 8(b) shows the same data plotted against ; the estimated suppression is now dependent on the perturbation amplitude. Hydrodynamics codes use the tunable flux limiter value to move between these curves.
Flux limiter formulation
The first consideration is the length-scale to be used in the flux limiter. The results of this paper are unambiguous: the delocalization lengths from table I.
Note that (to the author’s knowledge) only the Gorgon extended-MHD code19,32,33 currently uses (rather than ) to suppress heat-flow, although even Gorgon uses the Epperlein & Short9 form for .
The second open question is the form of the limiter in equation (23); there it is written as a hard cap on the maximum thermal conductivity, as is the orthodoxy in hydrodynamics codes:
Others have suggested a harmonic mean as more representative of kinetic simulations7,10,12:
Figure 9 demonstrates the inadequacy of these forms by plotting them against the unmagnetized VFP database. The sharp features from the ’min’ function are clearly not representing the smooth onset of kinetic suppression, as has been noted elsewhere12. The harmonic mean is an improvement, but overpredicts suppression at low and underpredicts at high .
This work instead proposes the following form for unmagnetized heat-flux, using equation (16):
with and . The delocalization length can be found in table I.
For magnetized heat-flow the conductivities become:
where equations 28 and 29 use the same and constants from equation (27). Equation 30 uses and , consistent with .
Note that all components use the same flux limiter value , so there are no additional tuning parameters despite having 3 heat-flux components.
All three components use a single scalar length-scale, , built from the full temperature gradient at the cell face. This differs from the construction of Ref.12, which assigned each component its own length-scale from the corresponding gradient component (). That choice looks natural but fails a simple case: the unmagnetized result is not recovered as unless is exactly parallel or perpendicular to . With one the limit is exact at every angle: as , and , so equations 28–30 reduce to equation (26) identically. The VFP database validates this construction in the two limiting geometries it contains, and ; mixed geometries, where a gradient-weighted length-scale such as would differ, are not tested here.
The relation between the global-scale fit and its local-scale implementation is exact for a single mode: at the point of steepest gradient, so equation (26) with reproduces Figure 8(b) with no additional fitting, and the flux limiter value scales linearly with the perturbation amplitude. For temperature structures of order-unity amplitude, and the model has no free parameter. Two caveats keep as a tunable rather than a constant. The linear response measured here is a result, and its extrapolation to is untested; and a hydrodynamics code resolves a superposition of modes whose amplitudes it cannot separate. The value of therefore retains a physical meaning as the effective amplitude of the temperature structures being resolved; its tuned range in the literature, 0.05–0.2, is consistent with of order unity.
Conclusion
Electron-electron collisions reduce the impact of kinetics on plasma transport through lowering the average velocity of electrons carrying heat-flux. The delocalization length has therefore been formulated to remove the ionization dependence of kinetic suppression of heat-flow.
Figure 9. Comparison of different flux limiter forms against the unmagnetized VFP database. Dotted: minimum function flux limiter from equation (24). Dashed: harmonic flux limiter from equation (25). Solid: flux limiter form proposed here in equation (27), which is based off .
Magnetization also makes plasma transport across field lines more classical in nature; is found to represent this behavior faithfully, where is the delocalization Hall parameter. is found to be larger than the carrier Hall parameter , demonstrating that the electrons responsible for non-locality are more easily magnetized than the heat-flux carriers.
Non-locality can therefore be assessed for plasma transport through the improved Knudsen number:
where the prefactor is chosen such that the heat-flow is 50% suppressed at . is essentially unaffected by kinetics (3.1%) and is highly suppressed (92.7%).
Righi-Leduc heat-flux is affected by kinetics more easily than the other components due to its reliance on higher energy electrons. It is found to relocalize by magnetization at the same rate as perpendicular heat-flow.
These findings allow for an improved flux limiter to be implemented into radiation-hydrodynamics and magneto-hydrodynamics codes. It may also allow for an improved SNB model34, e.g. through removing the arbitrary length multiplier22,25 and allowing for magnetization through the delocalization Hall parameter .
The following paper in the series will apply this methodology to the kinetic suppression of Nernst10,12 and Biermann battery generation11,23; this work stays in the regime of marginal non-locality. Extending the database into ’deep non-locality’ will be the subject of future work.
Acknowledgments
The author would like to thank Mark Sherlock for encouraging use of the K2 code, and valuable discussions on kinetic theory. Deserved appreciation also goes to George Zimmerman for noticing numerical issues with the Walsh & Sherlock flux limiter implementation discussed at the end of section VI B.
This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.
This document was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor Lawrence Livermore National Security, LLC, nor any of their employees makes any warranty, expressed or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States government or Lawrence Livermore National Security, LLC. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States government or Lawrence Livermore National Security, LLC, and shall not be used for advertising or product endorsement purposes.
The data that support the findings of this study are available from the corresponding author upon reasonable request.
Importance of e-e collision operator
This section uses classical calculations to demonstrate why a full e-e operator is required when assessing non-locality.
Three treatments of the e-e collisions are considered in the classical limit, using (where e-e collisions are most important). First, completely neglecting e-e collisions (equivalent to the Lorentz limit). Second, using the Epperlein & Short approximation, which scales the collision frequency uniformly across the electron distribution by 9. Finally, using the full e-e collision operator20, which is velocity dependent.
Figure 10(a) shows the solved against for the 3 cases. Figure 10(b) then shows how that affects the heat-flow moment (). The main impact of e-e collisions is to reduce the magnitude of the moment, thereby reducing the thermal conductivity to . Figure 10(c) shows that the Epperlein & Short approximation reproduces the -dependence of the conductivity. Note that this is by design: . What the Epperlein & Short approximation does not account for is the shift in the peak of due to the velocity-dependent nature of e-e collisions. This is apparent in Figure 10(b), with the peak of remaining at when the Epperlein & Short approximation is utilized; the velocity of the heat-carrying electrons is unchanged.
Figure 10. (a) electron velocity distribution and (b) heat-flow velocity moment for a plasma in the classical limit. Shown are 3 cases: no e-e collisions; Epperlein & Short approximation for e-e collisions9; full e-e collision operator. The approximation reduces the magnitude of heat-flow velocity moment, which allows it to reproduce the classical thermal conductivity, which is shown in (c). However, the Epperlein & Short approximation does not reproduce the down-shift of the heat-flow velocity moment, which affects the plasma non-locality.
When the full isotropic e-e collision operator is used, this instead drops to . Considering that collisional non-locality scales with , this demonstrates how the Epperlein & Short approximation overpredicts the non-locality of a plasma. The power of 4 suggests that the length-scale should be 13% smaller at . However, the true picture is more complex, as it is not just the peak carrier velocity that is important, but the full carrier-averaged quantity.
Assumptions and validated range
The results in this paper are the linear response of a kinetic plasma to a single sinusoidal temperature perturbation. The results apply to marginally non-local plasmas, with future work studying further corrections in the deeply non-local regime (). This section starts by addressing the accuracy of the suppression factor (equation 16) and relevant length-scales (table I), quoting the absolute deviations for the former and relative deviations for the latter.
The parameter range simulated is to 100, magnetization to 1 ( to 8.9, to 12.4), non-locality to 0.29 and perturbation amplitude to 0.08. Within that range the suppression of heat-flow follows equation 16 to an RMS of 0.0024 in unmagnetized, 0.011 magnetized perpendicular (), and 0.019 for Righi-Leduc, against the held-out VFP simulations.
The worst deviation (VFP minus fit) for unmagnetized heat-flow is in at , . For magnetized perpendicular () that is at , , . For Righi-Leduc the worst deviation is at , , .
For there is evidence of more complicated behavior emerging, with magnetization becoming dependent on ; therefore the results here are intended as applying to marginally non-local transport.
Appendix B 1 quantifies the importance of including harmonics above in this work and demonstrates convergence at . Appendix B 2 shows that linear superposition applies to the results of this paper.
Truncation of the harmonic expansion
The simulations and linear mode solver in this paper truncate the spherical-harmonic expansion at . Table II shows the effect of the truncation, comparing the suppression factors at truncations – against across the linear mode database (–100, –3). Truncation error vanishes in the local limit and grows with non-locality; it is largest for Righi-Leduc, which is carried by the fastest electrons. truncation is not sufficient for these results, with errors in up to 0.06 and up to 0.24; at the truncation error is below throughout the fitted range.
| , | , | , | , | |
| 1 | 0.061 | 0.22 | 0.064 | 0.24 |
| 2 | 0.049 | 0.018 | 0.095 | |
| 3 | 0.032 | |||
| 4 | ||||
| 5 | ||||
| 6 |
Table II. Maximum absolute error in the suppression factors when truncating at , relative to , over and . includes the unmagnetized .
Superposition
Until this section all simulations used a single-mode temperature perturbation. Realistic plasmas naturally contain a superposition of modes.
The observed behavior of the single-mode simulations is asserted to be the ‘linear response’; if this is true, multiple modes are expected to react as a superposition of independent modes with no mode coupling.
Two-mode simulations were initialized using the following temperature profile:
These were run at and 50 using , 0.086 and 0.250 and a second mode at twice and three times that wavenumber. The mode amplitudes were kept the same for each run (), which is deemed the strictest test of linear response. was varied between simulations at and 0.020. These runs were unmagnetized.
Conceptually, superposition requires that mode (= 1, 2 for two-mode) has its own thermal conductivity () that acts exclusively on the temperature perturbation of that mode . Each mode’s conductivity is extracted from the Fourier components of the heat-flow and temperature, and compared with a single-mode run at identical conditions.
The conductivities agree to 2.0% (relative) on average at and 2.4% at $\delta = 0.020. The decomposed modes acted as if the other modes were not present. Linear superposition holds.
Linear mode solver
The full VFP simulations (section III) evolve a temperature perturbation in time until it settles into a steady decay; then the heat-flux is read out of the simulation and compared to the classical value. The linear mode solver instead finds the state directly, as the slowest-decaying temperature eigenmode of the linearized VFP equations at a given , and .
The linear mode solver is built from the same collision operators, velocity grid and harmonic truncation as the VFP code, with the harmonics – treated as quasi-static. As in the VFP database, each mode is normalized by a nearly local mode () at the same and .
Evaluated at the same conditions as each of the 299 VFP simulations, it reproduces the suppression factors to a median of for (maximum 0.002), and for both (maximum 0.003) and (maximum 0.004), an order of magnitude below the accuracy of the fits.
Each calculation takes seconds, which allows for the generation of datapoints rather than several hundred using the time-evolved VFP calculation. The database spans –, – and – (logarithmically spaced). Higher velocity resolution () is used for the fits, while a separate database at moderate resolution () is used for comparison with the full VFP data. The fits use , with the magnetized constants fitted on only. The author hopes these will serve as reference fits for the linear kinetic response of plasma transport.
Kinetic carrier velocities
Previous work6 fitted the classical electron carrier velocity for heat-flux as a function of and ; this was the function used to generate Figure 1.
The carrier velocity is now extended to the kinetic regime using the kinetic database in this paper:
Where is the mean speed of in units of and the subscript denotes the classical carrier velocity. The argument (from equation (11)) reduces to (from equation (8)) in the unmagnetized case. Non-locality reduces the carrier velocity alongside classical magnetization and e-e collisions.
The Righi-Leduc carriers, defined as the mean speed of , follow the same form. Classically they are faster than the perpendicular heat-flux carriers and are slowed less by magnetization6. Under non-locality, normalizing each run by its classical reference,
to an RMS of 0.005. The Righi-Leduc carriers lose more of their speed than the perpendicular carriers (0.718 against 0.775 in the non-local limit), consistent with Righi-Leduc being carried by faster electrons and so being more strongly suppressed (section V A).
References
- [1]¹L. Spitzer and R. Härm, Physical Review 89, 977 (1953).
- [2]²S. I. Braginskii, in Reviews of Plasma Physics, Vol. 1 (1965) pp. 205–205.
- [3]³E. M. Epperlein and M. G. Haines, Physics of Fluids 29 (1986), 10.1063/1.865901.DOI
- [4]⁴J. D. Sadler, C. A. Walsh, and H. Li, Physical Review Letters 126, 075001 (2021).
- [5]⁵J. R. Davies, H. Wen, J.-Y. Ji, and E. D. Held, Physics of Plasmas 28, 012305 (2021).
- [6]⁶C. A. Walsh, arXiv:2610.30303 (2026).arxiv.org/abs/2610.30303
- [7]⁷R. C. Malone, R. L. McCrory, and R. L. Morse, Physical Review Letters 34, 721 (1975).
- [8]⁸J. F. Luciani, P. Mora, and J. Virmont, Physical Review Letters 51, 1664 (1983).
- [9]⁹E. M. Epperlein and R. W. Short, Physics of Fluids B: Plasma Physics 3, 3092 (1991).
- [10]¹⁰J. P. Brodrick, M. Sherlock, W. A. Farmer, A. S. Joglekar, R. Barrois, J. Wengraf, J. J. Bissell, R. J. Kingham, D. D. Sorbo, M. P. Read, and C. P. Ridgers, Plasma Physics and Controlled Fusion 60, 084009 (2018).
- [11]¹¹J. R. Davies, Physics of Plasmas 30, 072701 (2023).
- [12]¹²C. Walsh and M. Sherlock, “Kinetic Corrections to Heat-flow and Nernst advection for Laser Heated Plasmas,” (2024).arxiv.org/abs/2406.17942
- [13]¹³Y. Y. Lau, D. J. Strozzi, M. Sherlock, M. Weis, A. S. Joglekar, W. A. Farmer, Y. Shi, and J. R. C. Ray, Physics of Plasmas 32, 082104 (2025).
- [14]¹⁴J. D. Moody, B. B. Pollock, H. Sio, D. J. Strozzi, D. D.-M. Ho, C. A. Walsh, G. E. Kemp, B. Lahmann, S. O. Kucheyev, B. Kozioziemski, E. G. Carroll, J. Kroll, D. K. Yanagisawa, J. Angus, B. Bachmann, S. D. Handrakan, J. D. Budde, L. Divol, B. Ferguson, J. Fry, L. Hagler, E. Hartouni, M. C. Herrmann, W. Hsing, D. M. Holunga, N. Izumi, J. Javedani, A. Johnson, S. Khan, D. Kalantar, T. Kohut, B. G. Logan, N. Masters, A. Nikroo, N. Orsi, K. Piston, C. Provencher, A. Rowe, J. Sater, K. Skulina, W. A. Stygar, V. Tang, S. E. Winters, G. Zimmerman, P. Adrian, J. P. Chittenden, B. Appelbe, A. Boxall, A. Crilly, S. O’Neill, J. Davies, J. Peebles, and S. Fujioka, Physical Review Letters 129, 195002 (2022).
- [15]¹⁵P. Y. Chang, G. Fiksel, M. Hohenberger, J. P. Knauer, R. Betti, F. J. Marshall, and D. D. Meyerhofer, Physical Review Letters 103, 035006, (2011).
- [16]¹⁶C. K. Li, F. H. Séguin, J. A. Frenje, J. R. Rygg, R. D. Petrasso, R. P. J. Town, P. A. Amendt, S. P. Hatchett, O. L. Landen, A. J. Mackinnon, P. K. Patel, V. A. Smalyuk, T. C. Sangster, and J. P. Knauer, Physical Review Letters 97 (2006), 10.1103/PhysRevLett.97.135003.DOI
- [17]¹⁷R. Willingale, A. G. R. Thomas, P. M. Nilson, M. C. Kaluza, S. Bandyopadhyay, A. E. Dangor, R. G. Evans, P. Fernandes, M. G. Haines, C. Kamperidis, F. J. R. Kingham, S. Minardi, M. Notley, C. P. Ridgers, W. Rozmus, M. Sherlock, M. S. Tatarakis, M. Z. Wei, Z. Najmudin, and K. R. Kushnellick, Physical Review Letters 105 (2010), 10.1103/PhysRevLett.105.095001.DOI
- [18]¹⁸W. A. Farmer, J. M. Koning, D. J. Strozzi, D. E. Hinkel, L. F. Berzak Hopkins, O. S. Jones, and M. D. Rosen, Physics of Plasmas 24, 052703 (2017).
- [19]¹⁹C. Walsh, J. C. Chittenden, K. McGlinchey, N. Niasse, and B. Appelbe, Physical Review Letters 118, 155001 (2017).
- [20]²⁰M. Tzoufras, A. Bell, P. Norreys, and F. Tsung, Journal of Computational Physics 230, 6475 (2011).
- [21]²¹A. V. Brantov, V. Yu. Bychenkov, W. Rozmus, C. E. Capjack, and R. Sydora, Physics of Plasmas 10, 4633 (2003).
- [22]²²M. Sherlock, J. P. Brodrick, and C. P. Ridgers, Physics of Plasmas 24, 082706 (2017).
- [23]²³M. Sherlock and J. J. Bissell, Physical Review Letters 124, 055001 (2020).
- [24]²⁴N. R. Shaffer, M. Sherlock, A. V. Maximov, and V. N. Goncharov, Physics of Plasmas 30, 043906 (2023).
- [25]²⁵J. P. Brodrick, R. J. Kingham, M. M. Marinak, M. V. Patel, A. V. Chankin, J. T. Omotani, M. V. Umansky, D. Del Sorbo, B. Dudson, J. T. Parker, G. D. Kerbel, M. Sherlock, and C. P. Ridgers, Physics of Plasmas 24, 092309 (2017).
- [26]²⁶R. Kingham and A. Bell, Journal of Computational Physics 194, 1 (2004).
- [27]²⁷E. M. Epperlein and R. W. Short, Physics of Fluids B: Plasma Physics 3, 3092 (1991).
- [28]²⁸O. S. Jones, L. J. Suter, H. A. Scott, M. A. Barrios, W. A. Farmer, S. B. Hansen, D. A. Liedahl, C. W. Mauche, A. S. Moore, M. D. Rosen, J. D. Salmonson, D. J. Strozzi, C. A. Thomas, and D. P. Turnbull, Physics of Plasmas 24, 056312 (2017).
- [29]²⁹W. A. Farmer, O. S. Jones, M. A. Barrios, D. J. Strozzi, J. M. Koning, G. D. Kerbel, D. E. Hinkel, J. D. Moody, L. J. Suter, D. A. Liedahl, N. Lemos, D. C. Eder, R. L. Kauffman, O. L. Landen, A. S. Moore, and M. B. Schneider, Plasma Physics and Controlled Fusion 60, 044009 (2018).
- [30]³⁰W. A. Farmer, C. Bruulsema, G. F. Swadling, M. W. Sherlock, M. D. Rosen, W. Rozmus, D. H. Edgell, J. Katz, B. B. Pollock, and J. S. Ross, Physics of Plasmas 27, 082701 (2020), https://doi.org/10.1063/5.0005776.
- [31]³¹W. A. Farmer, M. D. Rosen, G. F. Swadling, C. Bruulsema, C. D. Harris, W. Rozmus, M. B. Schneider, M. W. Sherlock, D. H. Edgell, J. Katz, and J. S. Ross, Physics of Plasmas 28, 032707 (2021).
- [32]³²A. Ciardi, S. V. Lebedev, A. Frank, E. G. Blackman, J. P. Chittenden, C. J. Jennings, D. J. Ampleford, S. N. Bland, S. C. Bott, J. Rapley, G. N. Hall, F. A. Suzuki-Vidal, A. Marocchino, T. Lery, and C. Stehle, in *Physics of Plasmas*, Vol. 14 (2007).
- [33]³³J. Chittenden, N. Niasse, S. Bland, G. Hall, S. Lebedev, and C. A. Jennings, in 2009 IEEE International Conference on Plasma Science - Abstracts (IEEE, 2009) pp. 1–1.
- [34]³⁴G. P. Schurtz, Ph. D. Nicolaï, and M. Busquet, Physics of Plasmas 7, 4238 (2000).