Time-delay interferometry (TDI) cancels the laser frequency noise that dominates the measurements of the Laser Interferometer Space Antenna (LISA), and relies on interpolating the laser noise to fractional delays. In TDI-∞\infty, which finds the laser noise free combinations from a linear model of the measurements, the interpolation sets the design matrix, and any interpolation error leaves uncanceled laser noise which is not accounted for. We introduce Gaussian process (GP) interpolation into TDI-∞\infty, which models the laser noise from its spectrum and propagates its interpolation error into the likelihood as a covariance. We test it on a realistic data model in which the measurements pass through the on-board anti-alias filter and are downsampled to the 4 Hz telemetry rate, either applying the filter after the delays, as on the spacecraft, or building the filter into the GP kernel. We compare it with Lagrange and cosine-sum interpolation, and also keep the column space of the design matrix, which the standard null space likelihood discards. In lisainstrument simulations all three interpolators cancel the laser noise for a 1 Hz filter band edge, but only the GP does so up to the 2 Hz Nyquist frequency, a range the Lagrange and cosine-sum interpolators were not designed for. In parameter estimation on 200 simulated galactic binaries, the GP with the filter in its kernel gives the smallest calibrated posteriors. The differences are small for a single long data segment and grow when the data are split into short chunks or contain gaps, where the column space also recovers some information, by an amount that depends on the threshold that defines the null space.

Introduction

The Laser Interferometer Space Antenna (LISA) (Amaro-Seoane et al. 2017) is a future space-based gravitational wave detector that will observe gravitational waves in the millihertz band (Colpi et al. 2024). It consists of three spacecraft forming a triangle of side ∼2.5\sim2.5 million kilometres, connected by laser links. Unlike ground-based detectors, the arm lengths are unequal and vary with time, so the frequency noise of the lasers does not cancel naturally and is orders of magnitude larger than any other noise source. This laser noise must be removed before gravitational waves can be detected.

The noise from each laser is recorded in more than one measurement, since the beam from a given laser is beaten against a local laser both at its own spacecraft and, after propagating along an arm, at the distant spacecraft. The same noise therefore appears in several measurements at different delays, and can be cancelled in post-processing by combining those measurements with the appropriate delays in a process called time-delay interferometry (TDI) (Tinto & Dhurandhar 2021). Traditional TDI consists of fixed analytic combinations of the delayed measurements that cancel the laser noise (Armstrong et al. 1999), and second-generation combinations extend this to the slowly time-varying LISA arms (Tinto et al. 2023).

Another approach, TDI-∞\infty (Vallisneri et al. 2021), builds on the principal-component view of laser-noise cancellation (Romano & Woan 2006). It writes the likelihood directly in terms of the raw measurements and marginalises over the laser noise in a linear model of the measurements, rather than using a fixed set of analytically constructed combinations. This handles time-varying delays, data gaps, and additional primary noises such as optical-bench and clock noise within a single framework, where traditional TDI treats each with a separate processing step.

TDI-∞\infty has so far been demonstrated on simplified datasets, for example for tilt-to-length noise estimation (Houba et al. 2023) and for parameter inference in the presence of data gaps (Houba et al. 2024). In both of these, the on-board filtering and downsampling of the real instrument was not included, and the design matrix was built and applied at the same sample rate as the simulated data. In a realistic LISA setting the frequency or phase measurements are first made on board at a rate of 80 MHz, then filtered by an anti-aliasing filter and downsampled to the telemetry rate of 4 Hz before being sent to the ground (Bayle & Hartwig 2023). On board this decimation is done as a cascade of stages (Staab et al. 2023). We model it as a single anti-alias filter, which gives the same effective band limit. In this work we reproduce this structure at a reduced physics rate, which is computationally tractable while retaining the same filtering and downsampling. The design matrix therefore cannot be built at the rate at which the laser noise actually occurs, which raises the question of how the filtering, downsampling and interpolation should be represented in the design matrix.

Two further factors arise with a realistic data model: First, at the telemetry rate the fractional delays must be interpolated close to the Nyquist frequency, where Lagrange (Shaddock et al. 2004) and cosine-sum (Staab et al. 2025) interpolators lose accuracy, and their finite kernels mean data is discarded data at the edges of every chunk. Second, the standard TDI-∞\infty likelihood keeps only the null space of the design matrix, which is exact only in the limit of infinite laser noise.

In this work we extend TDI-∞\infty to this more realistic case of filtered and downsampled data. We first review the construction of the design matrix and its null space (§ 2), and introduce Gaussian process (GP) interpolation as an alternative to Lagrange and cosine-sum interpolation, which includes the interpolation error in the likelihood (§ 3). We then set up the filtered and downsampled data model, including the on-board anti-alias filter, with two models (§ 4), and define a likelihood that keeps both the null space and the column space of the design matrix, to test how much signal information is lost when the column space is discarded (§ 5). After describing the simulated data (§ 6), we compare the interpolators on how accurately they reproduce fractional delays and how much residual laser noise they leave (§ 7) and measure the cost of splitting the design matrix into chunks (§ 8). Finally we run parameter estimation on a galactic binary injected into lisainstrument (Bayle & Hartwig 2023) simulations with all primary and secondary noises, over 200 injections, testing the interpolators and likelihoods with a wider filter band, short chunks and data gaps (§ 9).

TDI-∞\infty background

This section is a summary of the setup used in Houba et al. (2024) which we follow in later sections. LISA is made of three spacecraft each containing two moving optical sub assemblies (MOSAs), each facing one of the other two spacecraft. Each MOSA contains a telescope, an optical bench, a test mass and is associated with its own laser. Each optical bench contains three interferometers, where each records the beatnote frequency between two lasers (Bayle & Hartwig 2023). The science interferometer scisci (labelled isiisi in Houba et al. (2024)) beats the local laser with the remote laser from the distant MOSA and contains the gravitational wave signal (Baghi et al. 2026). The test mass interferometer tmitmi beats the local laser reflected off the test mass with the laser of the adjacent MOSA. This measures the motion of the optical bench relative to the free-falling test mass, allowing the jitter of the optical bench to be removed. The reference interferometer refref beats the same two lasers as the tmitmi but without reflecting off the test mass. This measures the difference between the two lasers on a spacecraft, which is needed to combine the MOSA measurements. Each laser is phase modulated with the spacecraft clock signal, this creates laser sidebands and the beatnotes of these sidebands for the refref and scisci are also recorded to cancel clock noise later. As in Houba et al. (2024) we use 24 of these measurements: 6 scisci, 6 tmitmi, 3 refref with 6 scisci sidebands and 3 refref sidebands. Only three refref measurements are kept as the two on a single spacecraft compare the same two lasers and so carry the same primary noise (Bayle & Hartwig 2023).

There are two main groups for the noises in these measurements, primary and secondary. There are 18 primary noises, which appear in more than one measurement. This contains the laser frequency noise of the 6 lasers, the jitter of the 6 optical benches and the noise of the 3 clocks and the 3 dominant sideband modulation noises (Bayle & Hartwig 2023; Hartwig & Bayle 2021). The secondary noises are different for each measurement so appear once, this includes the readout noise of each interferometer. The primary goal of TDI-∞\infty is to cancel the primary noises p\boldsymbol{p} from the data, as the laser noise in particular is orders of magnitude larger than the secondary noises and the signal (Colpi et al. 2024).

Data model

In the idealised setup used by existing implementations (Vallisneri et al. 2021; Houba et al. 2024) the data can be written as

y=Mp+n+h(θ),(1)\boldsymbol{y} = M\boldsymbol{p} + \boldsymbol{n} + \boldsymbol{h}(\theta), \tag*{(1)}

where for NtN_t time samples assuming everything is at the 4 Hz telemetry rate, y\boldsymbol{y} are the Ny=24N_y = 24 telemetry-rate measurements, p\boldsymbol{p} are the Np=18N_p = 18 primary noises, MM is the design matrix that encodes the delays and maps the primary noises onto the measurements, n\boldsymbol{n} are the secondary noises and h(θ)\boldsymbol{h}(\theta) is the response of a measurement to some astrophysical signal with parameters θ\theta. Therefore y,n,h∈RNyNt\boldsymbol{y},\boldsymbol{n},\boldsymbol{h} \in\mathbb{R}^{N_y N_t}, p∈RNpNt\boldsymbol{p} \in\mathbb{R}^{N_p N_t} and M∈RNyNt×NpNtM \in\mathbb{R}^{N_y N_t \times N_p N_t}, where MM is not a square matrix.

In equation (1) the MpM\boldsymbol{p} terms are orders of magnitude larger than n\boldsymbol{n} or h(θ)\boldsymbol{h}(\theta) and need to be removed (Colpi et al. 2024; Tinto & Dhurandhar 2021). The values of p\boldsymbol{p} are unknown, however as they appear in more than one measurement via the delays (Tinto & Dhurandhar 2021), this can be modelled with MM. TDI-∞\infty uses the delays and model MM to cancel the primary noise, this needs an accurate MM.

Design matrix

MM has 24 rows and 18 columns per time sample, relating the 18 primary noises to the 24 measurements. The rows of MM are built using the all-in-one measurement equations of Houba et al. (2024), however we label the inter-spacecraft interferometer measurements scisci rather than isiisi in accordance with the LISA science conventions document (Baghi et al. 2026). The test mass and reference measurements compare lasers from the same spacecraft, therefore every noise enters at the same time and their rows have essentially no delays. The science and science sideband measurements on MOSA ijij compare the local laser with the laser from MOSA jiji. The noise then enters through the Doppler delay operator (Bayle & Hartwig 2023), which acts on a time series x(t)x(t)

D˙ijx(t)=(1−d˙ij(t))x(t−dij(t)),(2)\dot{\mathcal{D}}_{ij}x(t) = \left(1-\dot{d}_{ij}(t)\right)x\left(t-d_{ij}(t)\right), \tag*{(2)}

where dijd_{ij} is the light travel time along link ijij. A row of MM for a science measurement then has two sets of entries: those at the time of the measurement, for the noises local to the MOSA, and those at the delayed time, for the noises of the distant MOSA. The delayed time does not in general fall on a sample pp, so the delayed entries are spread over neighbouring samples with an interpolator. The standard choice, introduced for TDI in Shaddock et al. (2004) and used in Houba et al. (2024), is Lagrange interpolation. The interpolators we use are described in § 3. Figure 1 shows this structure for a single science measurement and two of the laser noises. The entries of −1-1 in the p12p_{12} section are the local measurements, and the spread entries in p21p_{21} are the delayed and interpolated measurements. The lower panel shows a single row of the MM matrix.

Figure 1. Structure of the design matrix MM, showing the mapping from the laser noises p12,p21p_{12}, p_{21} (columns) to the science measurements sci12,sci21sci_{12}, sci_{21} (rows). Local measurements of the laser are −1-1 (blue) and delayed measurements are positive and interpolated. The solid horizontal line shows which two noises contribute to a measurement, a local measurement and an interpolated delayed measurement. The vertical dashed line highlights a column where there are two measurements of a particular primary noise at the same time, which is what allows cancellation.

Null space

The goal in TDI-∞\infty is to cancel the primary noise p\mathbf{p} from only indirect measurements in y\mathbf{y}. Therefore if we can find a matrix U0U_0 such that

U0TM=0,(3)U_0^{T} M = 0, \tag*{(3)}

then pre-multiplying the data y\mathbf{y} by U0TU_0^{T} would remove the primary noise (Vallisneri et al. 2021; Houba et al. 2024). In Vallisneri et al. (2021); Houba et al. (2024) the variable TT is used for the null space such that TM=0TM = 0, our equivalent matrix is U0TU_0^{T}. Each of the primary noises enters more than one measurement, i.e. the local and delayed measurement. Therefore there are more measurements than primary noises and the rows of MM cannot all be independent, so some combinations will sum to zero. These combinations make the left null space of the matrix MM and they are the columns of U0U_0.

In Houba et al. (2024) U0U_0 is found using a turnback algorithm which they compare against Scipy’s singular value decomposition (SVD) based null space Virtanen et al. (2020). Here we use the SVD of the design matrix as in Vallisneri et al. (2021),

M=UΣVT,(4)M = U\Sigma V^{T}, \tag*{(4)}

where the columns of UU with zero singular value form U0U_0 and the remaining form the column space UrU_r. Numerically we set a threshold below which the singular values are considered zero, this is discussed in § 7.

Projecting the data with U0U_0 gives the TDI-∞\infty variables

o0=U0Ty=U0Tn+U0Th(θ),(5)o_0 = U_0^{T}\mathbf{y} = U_0^{T}\mathbf{n} + U_0^{T}h(\theta), \tag*{(5)}

which removes the primary noise and leaves the secondary noises and the signal (Vallisneri et al. 2021; Houba et al. 2024). In Houba et al. (2024) the likelihood is built from o0o_0, we give this and its extension to the column space in § 5.

When the delays are not on integer samples in the laser noise axis of the design matrix, we need to interpolate between the times. The standard approach, introduced for TDI in Shaddock et al. (2004), uses Lagrange interpolation described in § 3.1.

Interpolation

To compute the non integer delays, one needs to interpolate over previous times. Here we compare three different interpolation methods, Lagrange (Shaddock et al. 2004; Bayle & Hartwig 2023), cosine-sum (Staab et al. 2025) and Gaussian processes (Rasmussen & Williams 2005; Moore et al. 2016).

Lagrange

For some delay time τ=n+μ\tau= n + \mu, where nn is an integer number of samples and 0≤μ<10 \le\mu< 1 is the fractional part, the time series ss is interpolated with

s^(τ)=∑k=−KKwk(μ) s(n+k),(6)\hat{s}(\tau) = \sum_{k=-K}^{K} w_k(\mu)\,s(n+k), \tag*{(6)}

where KK is the half width of the interpolation kernel. The Lagrange weights are

wk(μ)=∏j=−Kj≠kKμ−jk−j,(7)w_k(\mu) = \prod_{\substack{j=-K \\ j \ne k}}^{K} \frac{\mu-j}{k-j}, \tag*{(7)}

each of which is the polynomial that is one at sample kk and zero at the other samples, evaluated at μ\mu (Shaddock et al. 2004). Whilst the accuracy of this method can be tuned by selecting an appropriate order for the interpolation, any errors from the Lagrange interpolator are not accounted for in the output. If a large number of taps are needed then there is also data loss where data is trimmed at the edges to remove the edge effects of the interpolation kernel. These are the edges of each chunk rather than any gaps, the gaps we consider are in the telemetry samples, not in the noise itself, so the noise samples the kernel reads are complete across the gap and not affected by it.

Cosine sum

The cosine-sum interpolation was introduced in Staab et al. (2025). It has the same form as the Lagrange interpolator, with weights

wk(μ)=∑n=0N−1ancos⁡(2πn(k−μ)N),(8)w_k(\mu) = \sum_{n=0}^{N-1} a_n \cos\left(\frac{2\pi n(k-\mu)}{N}\right), \tag*{(8)}

where NN is the number of taps and kk covers the surrounding NN samples of the interpolated point. The coefficients ana_n are chosen in Staab et al. (2025) so that the interpolation residual stays within a stated requirement below 1 Hz and keeps continuous first derivatives. We use their 22 coefficients without refitting.

Gaussian process

An alternative to Lagrange interpolation is a GP, which propagates the interpolation error and uses the full data segment without truncation at the edges. A GP is defined by a kernel function k(τ)k(\tau), which we choose using a model of the noise being interpolated. Since we are interpolating stationary laser noise, we define the kernel as its auto-covariance. For a two-sided power spectral density S(f)S(f), the kernel is

k(τ)=∫−∞∞S(f)e2πifτ df,(9)k(\tau) = \int_{-\infty}^{\infty} S(f)e^{2\pi if\tau}\,\mathrm{d}f, \tag*{(9)}

which is the inverse Fourier transform of the noise spectrum (Rasmussen & Williams 2005). The laser noise itself is white, however we interpolate that noise after the on-board anti-alias filter, so for a noise variance σ2\sigma^2 and filter FF, S(f)=σ2∣F(f)∣2S(f)=\sigma^2\lvert F(f)\rvert^2 and the kernel is the autocorrelation of the filter impulse response, using the parameters described in § 6.1.

We interpolate a time series s(ti)s(t_i) described by a noise process S(f)S(f) to a target time series z(tα)z(t_\alpha). Note that the number of samples in both the time series ss and zz need not be equal. Latin time-indices correspond to the original time-series, Greek time-indices the new interpolated process. The GP uses three covariances between the samples and targets

kss(ti,tj)=k(ti−tj),ksz(tα,tj)=k(tα−tj),kzz(tα,tβ)=k(tα−tβ).(10)\begin{aligned} k_{ss}(t_i,t_j) &= k(t_i-t_j),\\ k_{sz}(t_\alpha,t_j) &= k(t_\alpha-t_j),\\ k_{zz}(t_\alpha,t_\beta) &= k(t_\alpha-t_\beta). \tag*{(10)} \end{aligned}

In the following all vectors are over the sampled times so (K)ij=Kij=kss(ti,tj)(K)_{ij}=K_{ij}=k_{ss}(t_i,t_j) and (k(tα))j=kj(tα)=ksz(tα,tj)(k(t_\alpha))_j=k_j(t_\alpha)=k_{sz}(t_\alpha,t_j). This then gives us the posterior mean of a GP (Rasmussen & Williams 2005)

z^(tα)=k(tα)TK−1s,(11)\hat{z}(t_\alpha)=k(t_\alpha)^{T}K^{-1}s, \tag*{(11)}

so we can write the weights w(tα)=kT(tα)K−1w(t_\alpha)=k^{T}(t_\alpha)K^{-1} as the interpolation coefficients that populate the corresponding row of the telemetry-rate design matrix MM, in place of the Lagrange weights.

Unlike the Lagrange interpolator, the GP posterior also provides the covariance of the interpolation error (Moore et al. 2016). This GP posterior covariance is defined by

Cϵ(tα,tβ)=kzz(tα,tβ)−kT(tα)K−1k(tβ).(12)C_{\epsilon}(t_\alpha,t_\beta)=k_{zz}(t_\alpha,t_\beta)-k^{T}(t_\alpha)K^{-1}k(t_\beta). \tag*{(12)}

CϵC_{\epsilon} is a full covariance over target times and between measurements that share the delayed laser, while the errors of the lasers are independent in this setup.

Realistic filtered data model

The idealised model in equation (1) leaves out the on-board data processing. On the spacecraft, each measurement is made with the 80 MHz on-board rate (Bayle & Hartwig 2023) as a sum of the local and delayed primary noise terms, the secondary noises and the signal. It is then filtered with the anti-alias filter and downsampled to the 4 Hz telemetry rate (Bayle & Hartwig 2023; Staab et al. 2023). This model is built into the data description in Houba et al. (2024) but not used in the building of the MM matrix. In the form of equation (1) the model for a chunk of data can be written

y=SF(Mϕφϕ+nϕ+hϕ(θ))=P+SFnϕ+SFhϕ(θ),(13)\begin{aligned} \boldsymbol{y} &= SF(M_\phi\boldsymbol{\varphi}_\phi+\boldsymbol{n}_\phi+\boldsymbol{h}_\phi(\theta))\\ &= \boldsymbol{P}+SF\boldsymbol{n}_\phi+SF\boldsymbol{h}_\phi(\theta), \tag*{(13)} \end{aligned}

where MϕM_\phi is the design matrix and subscript ϕ\phi refers to its sample rate at 80 MHz, FF applies the anti-alias filter to each measurement across time, with the filter taps clc_l which have LL taps at the on-board sample interval. SS downsamples by keeping samples at the telemetry times and P=SFMϕφϕ\boldsymbol{P}=SFM_\phi\boldsymbol{\varphi}_\phi. The filter also introduces a group delay to the measurements, however, this is corrected on the ground and is assumed to be a fixed offset here so does not change the combinations that cancel laser noise, so we omit it and account for it later by shifting the signal template in § 6.3.

We can then write out the log likelihood in terms of the time series measurements y\boldsymbol{y}. We assume here a Gaussian likelihood and that the primary φϕ\boldsymbol{\varphi}_\phi and secondary nϕ\boldsymbol{n}_\phi are zero mean and independent and with a known covariance. The time series likelihood is then

log⁡p(y∣θ)=−12(y−SFhϕ(θ))TCy−1(y−SFhϕ(θ))+const.,(14)\log p(\boldsymbol{y}\mid\theta)=-\frac{1}{2}\left(\boldsymbol{y}-SF\boldsymbol{h}_\phi(\theta)\right)^{T}C_y^{-1}\left(\boldsymbol{y}-SF\boldsymbol{h}_\phi(\theta)\right) +\mathrm{const.,} \tag*{(14)}

where the measurement covariance CyC_y is defined by

Cy=(SF)(MϕCφϕMϕT+Cnϕ)(SF)T.(15)C_y=(SF)\left(M_\phi C_{\varphi_\phi}M_\phi^{T}+C_{n_\phi}\right)(SF)^{T}. \tag*{(15)}

Here Cφϕ=E[φϕφϕT]C_{\varphi_\phi}=\mathbb{E}[\boldsymbol{\varphi}_\phi\boldsymbol{\varphi}_\phi^{T}] is the primary noise covariance and Cnϕ=E[nϕnϕT]C_{n_\phi}=\mathbb{E}[\boldsymbol{n}_\phi\boldsymbol{n}_\phi^{T}] is the secondary noise covariance.

Telemetry rate model

In practice MϕM_\phi is too large to build at the 80 MHz rate, therefore we write the model at the telemetry rate. This means that we must move SFSF through the delays in MϕM_\phi, however these do not commute. For the Doppler delay operator D^\hat{D}, Staab et al. (2023), eq. (17) split the error of swapping the delay with the filtering and downsampling into two parts

[SF,D^]=[S,D˙]F⏟aliasing+S[F,D˙]⏟flexing-filtering.(16)\left[SF,\hat{D}\right]=\underbrace{\left[S,\dot{D}\right]F}_{\text{aliasing}}+\underbrace{S\left[F,\dot{D}\right]}_{\text{flexing-filtering}}. \tag*{(16)}

The first term is aliasing, where the power the filter leaves above the 2 Hz telemetry Nyquist frequency is folded back into the band by SS. The second term is the ‘flexing filtering’, where the delay changes over the length of the filter, so the filter and delay do not commute (Bayle et al. 2019). In Harer et al. (2025), the filter is corrected for by applying a modified delay operator to the filtered and downsampled noise SFpSF\boldsymbol{p} (their Eq. 22)

D^=FD˙F−1.(17)\hat{D}=F\dot{D}F^{-1}. \tag*{(17)}

We take this and apply it to TDI-∞\infty, where as the design matrix is built from delayed and local terms, this same correction would apply to MM. At the telemetry rate the primary noise term becomes

P≈M^4SFϕ,M^4=F4M4F4−1,(18)P \approx\hat{M}_4SF_{\phi}, \qquad\hat{M}_4=F_4M_4F_4^{-1}, \tag*{(18)}

where M4M_4 is the design matrix of § 2.2 at the telemetry rate, F4F_4 is the filter resampled to 4 Hz. Both FF and F4F_4 apply the same filter to each time series separately, so their size is set by what they act on. We cannot form F4−1F_4^{-1} directly, however, we will never need to. The two models below are two ways of applying M^4\hat{M}_4. Model 1 in § 4.2 splits M^4\hat{M}_4 into an interpolation followed by the filter and handles flexing filtering but not aliasing and works with all interpolators from § 3. Model 2 in § 4.3 builds all of M^4\hat{M}_4 into the GP weights and can include both error terms, however is only applied to the GP interpolation. In both models each row of the design matrix combines local terms, which are the samples ss at the telemetry times, and delayed terms zz, which are interpolated from ss. The two models differ only in how they define ss and zz.

Model 1: delays before filter

In Model 1 we group the operators in equation (18) as

P≈(F4M4)(F4−1SFϕ)=F4M4s1(19)P \approx(F_4M_4)\left(F_4^{-1}SF_{\phi}\right)=F_4M_4s_1 \tag*{(19)}

where s1=F4−1SFϕs_1=F_4^{-1}SF_{\phi} is the noise at the telemetry rate with the filter undone. This effectively assumes that s1s_1 is band limited to 2 Hz, and there is no aliasing back into the band, so this model does not account for any aliasing. The unknowns in this case are s1s_1 so F4−1F_4^{-1} is never formed and the delayed terms are z1=D˙s1z_1=\dot{D}s_1. The interpolation weights in M4M_4 form the noise at the delayed times as combinations of s1s_1, F4F_4 is then applied to the result. As the delays are applied before the filter, this handles the flexing filtering of equation (16). The Lagrange and cosine-sum models fill M4M_4 with their interpolation weights from § 3.1 and § 3.2. The GP can be used here also as s1s_1 is white and band limited to 2 Hz, therefore the kernel of equation (9) is a sinc,

k(t)=σϕ2sinc⁡(t/Δt),(20)k(t)=\sigma_{\phi}^{2}\operatorname{sinc}(t/\Delta t), \tag*{(20)}

where Δt\Delta t is the telemetry sample spacing and σϕ2\sigma_{\phi}^{2} is the variance of a sample. The samples are then uncorrelated and K=σϕ2IK=\sigma_{\phi}^{2}I so the weights are just a sinc function. As s1s_1 and z1z_1 are the same unfiltered noise, all three covariances from § 3.3 are the same kernel read at different lags.

Model 2: filter in GP kernel

In Model 2 we model the whole M^4\hat{M}_4 and apply it directly to the filtered and downsampled noise,

P≈M^4(SFϕ)=M^4s2.(21)P \approx\hat{M}_4(SF_{\phi})=\hat{M}_4s_2. \tag*{(21)}

In this case the unknowns are the samples s2=SFϕs_2=SF_{\phi} and the GP weights in M^4\hat{M}_4 write the filtered delayed noise, z2≈D^˙4s2z_2\approx\dot{\hat{D}}_4s_2, with D^4=F4D˙F4−1\hat{D}_4=F_4\dot{D}F_4^{-1} as combinations of them. Reading the kernel of § 3.3 at the delayed time, kϕ(t,tj)=k(t−d−tj)k_{\phi}(t,t_j)=k(t-d-t_j), handles neither term of equation (16). Here we include the effects of aliasing through the kernel integrals and the flexing filtering through the filtered delayed terms, then build the GP from the resulting kernels.

Aliasing

To account for aliasing, the kernel in equation (9) is built over the full on-board band. Reading this kernel at samples separated by Δt\Delta t then includes the power above 2 Hz that SS folds in. The part that the GP cannot predict from the aliased samples is included in CϵC_{\epsilon}. We build the kernels from the on-board 16 Hz simulation rate, in practice one would have to select a rate for this lower than the 80 MHz such as this, however, we do not investigate that here.

Flexing filtering

Reading the kernel at a delayed time treats D^\hat{D} as D˙\dot{D}, which only holds for constant delay. For changing delays, we expand in the rate of change of the delay as Staab et al. (2023); Harer et al. (2025). To do this we write the samples s2=SFϕs_2=SF_{\phi} and a delayed term as sums over the filter taps. The samples are filtered noise at the telemetry times,

s2(tj)=∑l=0L−1clp(tj−tl),(22)s_2(t_j)=\sum_{l=0}^{L-1}c_l p(t_j-t_l), \tag*{(22)}

where tlt_l are the filter lags at the on-board sample interval, LL is the number of filter taps. A delayed term is an element of z2=SFD˙ϕ≈D˙s2z_2=SF\dot{D}\phi\approx\dot{D}s_2, which is the filtered delayed noise that M^4\hat{M}_4 predicts. On the spacecraft each delayed term is

z2(t)=∑l=0L−1cl(1−d˙(t−tl))p(t−tl−d(t−tl))(23)z_2(t)=\sum_{l=0}^{L-1}c_l\left(1-\dot{d}(t-t_l)\right)p\left(t-t_l-d(t-t_l)\right) \tag*{(23)}

If the delays were constant z2(t)=s2(t−d)z_2(t)=s_2(t-d) and the delay could be moved outside the filter. We assume however that the delay changes linearly over the filter length, and expand it to first order about the centre of the filter, which is a group delay tgt_g before tt

d(t−tl)≈dc+d˙c(tg−tl),(24)d(t-t_l)\approx d_c+\dot{d}_c(t_g-t_l), \tag*{(24)}

where dcd_c are the delay and its time derivative at the filters center t−tgt-t_g. We assume the d˙\dot{d} term becomes (1−d˙c)(1-\dot{d}_c), giving

z2(t)≈(1−d˙c)∑l=0L−1clp(t−dc−tl′),tl′=tl+d˙c(tg−tl).(25)z_2(t)\approx(1-\dot{d}_c)\sum_{l=0}^{L-1}c_l p(t-d_c-t'_l),\qquad t'_l=t_l+\dot{d}_c(t_g-t_l). \tag*{(25)}

This means that the delay dcd_c does not depend on the filter taps and acts after the filter. The change of the delay across the filter has moved into the lags. Therefore z2z_2 is the noise passed through a second filter with the same taps but lags tl′t'_l instead of tlt_l and read at tα=t−dct_{\alpha}=t-d_c. The two filters are then defined by

F(f)=∑lcle−2πiftl,F(f)=\sum_l c_l e^{-2\pi i f t_l},
Fz(f)=(1−d˙c)∑lcle−2πiftl′,(26)F_z(f)=(1-\dot{d}_c)\sum_l c_l e^{-2\pi i f t'_l}, \tag*{(26)}

where the term 1−d˙c1-\dot{d}_c is in FzF_z so that z2z_2 is the noise passed through FzF_z and read at tt. To first order in d˙cFz\dot{d}_cF_z reproduces the flexing filtering term of Staab et al. (2023), eq. 18, which Harer et al. (2025), eq. 24 use to correct for the delay. Where Harer et al. (2025) design an interpolation kernel for this correction, here it is contained in the GP through FzF_z.

GP kernels

The samples pass through the filter FF and are read at times tjt_j and a delayed term passes through FzF_z and is read at tαt_\alpha. The covariance between ss and zz then contains the power spectrum SpS_p and filters with the two different filters. The three kernels for the GP are therefore defined by

kss(ti,tj)=∫Sp∣F∣2e2πif(ti−tj) df,ksz(tα,tj)=∫SpFzF∗e2πif(tα−tj) df,kzz(tα,tβ)=∫SpFz,αFz,β∗e2πif(tα−tβ) df,(27)\begin{aligned} k_{ss}(t_i,t_j) &= \int S_p|F|^2 e^{2\pi i f(t_i-t_j)}\,\mathrm{d}f,\\ k_{sz}(t_\alpha,t_j) &= \int S_pF_zF^*e^{2\pi i f(t_\alpha-t_j)}\,\mathrm{d}f,\\ k_{zz}(t_\alpha,t_\beta) &= \int S_pF_{z,\alpha}F^*_{z,\beta}e^{2\pi i f(t_\alpha-t_\beta)}\,\mathrm{d}f, \tag*{(27)} \end{aligned}

where the integrals are over the full frequency band, and Fz,αF_{z,\alpha} is taken at time tαt_\alpha. When d˙c=0\dot{d}_c=0, Fz=FF_z=F and this reduces to equation (9). The weights and covariance then follow that from Section 3.3. The filter suppresses the stopband power by a factor of about 101810^{18}, which is below double precision. This makes the condition number of K∼1018K\sim10^{18} and when inverting it amplifies the float64 errors. We therefore form the kernel and CϵC_\epsilon and solve for the GP weights in 128-bit precision with python-flint (Johansson 2026).

Likelihood at telemetry rate

The likelihood from equation (14) can then be rewritten at the telemetry rate

log⁡p(y∣θ)∝−12(y−F4h4(θ))TCy−1(y−F4h4(θ)).(28)\log p(y\mid\theta)\propto-\frac{1}{2}(y-F_4h_4(\theta))^{T}C_y^{-1}(y-F_4h_4(\theta)). \tag*{(28)}

The measurement covariance CyC_y is defined by

Cy=MCsMT+C~n,(29)C_y=MC_sM^{T}+\widetilde{C}_n, \tag*{(29)}

where we combine the secondary noise covariance with the GP error covariance

C~n=F4Cn4F4T+C‾ϵ,(30)\widetilde{C}_n=F_4C_{n_4}F_4^{T}+\overline{C}_\epsilon, \tag*{(30)}

where C‾ϵ\overline{C}_\epsilon is the covariance from the GP and is only included for the matrices that use GP interpolation. In both models we can write the primary noise as MsMs, where ss are the unknown samples with covariance CsC_s. In Model 1, M=F4M4M=F_4M_4 and s=s1s=s_1 with each primary noise given its spectrum from Table 1, which is white for laser noise. In Model 2, M=M^4M=\widehat{M}_4 and s=s2s=s_2 with the same spectra multiplied by the filter ∣F∣2|F|^2. In Model 1, C‾ϵ=0\overline{C}_\epsilon=0 for the Lagrange and cosine-sum and C‾ϵ=F4CϵF4T\overline{C}_\epsilon=F_4C_\epsilon F_4^T for the GP. In Model 2, C‾ϵ=Cϵ\overline{C}_\epsilon=C_\epsilon is the GP covariance itself.

Table 1. Simulation and injection settings. The top section shows the noise levels used in the simulations, which are lisainstrument defaults (Bayle & Hartwig 2023). Test mass acceleration noise has the default spectrum with 0.4 mHz knee and 8 mHz break. Bottom shows the galactic binary injection priors, where AA, ff, ϕ\phi are drawn from uniform priors over the shown ranges and the remaining parameters are fixed to the stated values.

NoiseNo.ASD
Primary, marginalised
Laser frequency630 Hz/Hz30\ \mathrm{Hz}/\sqrt{\mathrm{Hz}}
Optical bench jitter62×10−9 m/Hz2 \times10^{-9}\ \mathrm{m}/\sqrt{\mathrm{Hz}}
Clock36.32×10−14/Hz6.32 \times10^{-14}/\sqrt{\mathrm{Hz}} at 1 Hz
Modulation35.2×10−13/Hz5.2 \times10^{-13}/\sqrt{\mathrm{Hz}} at 1 Hz
Secondary, not cancelled
OMS science carrier66.35×10−12 m/Hz6.35 \times10^{-12}\ \mathrm{m}/\sqrt{\mathrm{Hz}}
OMS science sideband61.25×10−11 m/Hz1.25 \times10^{-11}\ \mathrm{m}/\sqrt{\mathrm{Hz}}
OMS test-mass carrier61.42×10−12 m/Hz1.42 \times10^{-12}\ \mathrm{m}/\sqrt{\mathrm{Hz}}
OMS reference carrier63.32×10−12 m/Hz3.32 \times10^{-12}\ \mathrm{m}/\sqrt{\mathrm{Hz}}
OMS reference sideband67.90×10−12 m/Hz7.90 \times10^{-12}\ \mathrm{m}/\sqrt{\mathrm{Hz}}
Test-mass acceleration62.4×10−15 m s−2/Hz2.4 \times10^{-15}\ \mathrm{m}\,\mathrm{s}^{-2}/\sqrt{\mathrm{Hz}}
ParameterValue
Galactic binary, sampled, uniform prior range
AA(2×10−20,7×10−20)(2 \times10^{-20}, 7 \times10^{-20})
ff(0.02,0.05) Hz(0.02, 0.05)\ \mathrm{Hz}
ϕ0\phi_{0}(−π,π)(-\pi, \pi)
Galactic binary, fixed
α\alpha (RA)4.6511 rad4.6511\ \mathrm{rad}
δ\delta (Dec)−0.5060 rad-0.5060\ \mathrm{rad}
ι\iotaπ/3 rad\pi/3\ \mathrm{rad}
ψ\psi0.5 rad0.5\ \mathrm{rad}
f˙\dot{f}0

Table 1.

Likelihood definition

The TDI-∞\infty likelihood is usually written in terms of the null space of the design matrix. The laser noise is marginalised with an infinite variance prior, the remaining column space directions are dropped entirely (Vallisneri et al. 2021). This is a good approximation when the laser noise is large, however, the discarded directions can still carry information about the signal. In later sections we show how this matters for data split into short chunks or with gaps, and in Appendix B how it depends on the threshold that separates the two spaces. In this section we keep both spaces and write out the likelihood for each. The singular values of the design matrix set how much weight the column space is given.

We start with the likelihood definition in equation (28), whiten it with respect to the secondary noises and split the likelihood into null and column space components.

Whitening

To simplify the likelihood computation, we whiten the components of the likelihood by the secondary noise plus any interpolation error C~n\widetilde{C}_n, so that after laser noise cancellation the remaining noise is white. The data, signal template and design matrix are whitened by

yˉ=C~n−1/2y,\bar{y}=\widetilde{C}_n^{-1/2}y,
hˉ=C~n−1/2F4h4,\bar{h}=\widetilde{C}_n^{-1/2}F_4h_4,
Mˉ=C~n−1/2M.(31)\bar{M}=\widetilde{C}_n^{-1/2}M. \tag*{(31)}

We compute C~n−1/2\widetilde{C}_n^{-1/2} from the eigen decomposition of a known C~n\widetilde{C}_n, keeping only the NwN_w eigenvectors whose eigenvalues are above a fraction of the largest. This is then not a true inverse square root, but an Nw×NyN_w\times N_y projection onto the retained eigenvectors, so yˉ\bar{y}, hˉ\bar{h} and Mˉ\bar{M} each have NwN_w rows. The anti-alias filter suppresses the secondary noise in its stop band by more than double precision, so the smallest eigenvalues are round off and whitening to them would amplify numerical noise. In Appendix A we show that we can cut to a threshold of 10−1010^{-10} of the largest eigenvalue.

Singular value covariance

We take the singular value decomposition of the whitened design matrix, Mˉ=UΣVT\bar{M}=U\Sigma V^T, where Mˉ\bar{M} has NwN_w rows, from the whitening, and rank rr. We split the left singular vectors into the column space UrU_r and null space U0U_0, U=[Ur,U0]U=[U_r,U_0]. Projecting the whitened data onto these subspaces gives

o0=U0Tyˉ,o_0=U_0^T\bar{y},
or=UrTyˉ,(32)o_r=U_r^T\bar{y}, \tag*{(32)}

the null and column space projections. Together these are the full projection of the whitened data,

o=UTyˉ=[oro0],(33)o=U^T\bar{y}= \begin{bmatrix} o_r\\ o_0 \end{bmatrix}, \tag*{(33)}

which are the TDI-∞\infty observables, with the standard laser-free variables in Vallisneri et al. (2021); Houba et al. (2024) being the o0o_0 part alone. Whitening the covariance of equation (29) gives

Cˉy=MˉCsMˉT+I,(34)\bar{C}_y=\bar{M}C_s\bar{M}^T+I, \tag*{(34)}

so the covariance of the projected data oo, which we write CoC_o, is

Co=UTCˉyU=UT(MˉCsMˉT+I)U=UTMˉCsMˉTU+UTIU=primary noise+=secondary noise.(35)\begin{aligned} C_o &= U^T\bar{C}_yU\\ &=U^T\left(\bar{M}C_s\bar{M}^T+I\right)U\\ &=U^T\bar{M}C_s\bar{M}^TU+U^TIU\\ &\underset{\text{primary noise}}{\phantom{=}}+\underset{\text{secondary noise}}{\phantom{=}}. \tag*{(35)} \end{aligned}

Using Mˉ=UΣVT\bar{M}=U\Sigma V^T we can write UTMˉ=ΣVTU^T\bar{M}=\Sigma V^T and since UU is unitary UTIU=IU^TIU=I, giving

Co=(ΣVT)Cs(VΣT)+I.(36)C_o=(\Sigma V^T)C_s(V\Sigma^T)+I. \tag*{(36)}

Σ\boldsymbol{\Sigma} has non-zero entries only on the leading rr diagonal elements. Writing Σr\boldsymbol{\Sigma}_r for the r×rr \times r block that acts on the column space, the remaining Nw−rN_w-r rows of Σ\boldsymbol{\Sigma} are zero, and CoC_o is block diagonal,

Co=[Σr(VrTCsVr)ΣrT+Ir00INw−r].(37)C_o = \begin{bmatrix} \boldsymbol{\Sigma}_r(V_r^{T} C_s V_r)\boldsymbol{\Sigma}_r^{T} + I_r & 0 \\ 0 & I_{N_w-r} \end{bmatrix}. \tag*{(37)}

The null space block is the identity matrix as no laser noise should reach o0\mathbf{o}_0 and only the whitened secondary noise is left. The column space has the primary noise, including laser noise, weighted by the singular values.

Split likelihood

In equation (37) the covariance of the projected data is block diagonal, the likelihood of equation (28) then separates into null space and column space parts,

log⁡p(yˉ∣θ)=log⁡p(o0∣θ)+log⁡p(or∣θ).(38)\log p(\bar{\mathbf{y}} \mid\theta) = \log p(\mathbf{o}_0 \mid\theta) + \log p(\mathbf{o}_r \mid\theta). \tag*{(38)}

The null space part has covariance II of size Nw−rN_w-r,

log⁡p(o0∣θ)=−12∥o0−U0Thˉ∥2,(39)\log p(\mathbf{o}_0 \mid\theta) = -\frac{1}{2}\left\lVert\mathbf{o}_0-U_0^T\bar{\mathbf{h}}\right\rVert^2, \tag*{(39)}

and the column space part has covariance Cr=Σr(VrTCsVr)ΣrT+IrC_r=\boldsymbol{\Sigma}_r(V_r^T C_s V_r)\boldsymbol{\Sigma}_r^T+I_r,

log⁡p(or∣θ)=−12(or−UrThˉ)TCr−1(or−UrThˉ)\log p(\mathbf{o}_r \mid\theta) = -\frac{1}{2}\left(\mathbf{o}_r-U_r^T\bar{\mathbf{h}}\right)^T C_r^{-1}\left(\mathbf{o}_r-U_r^T\bar{\mathbf{h}}\right)
−12log⁡det⁡Cr.(40)-\frac{1}{2}\log\det C_r. \tag*{(40)}

Standard TDI-∞\infty ((Vallisneri et al. 2021)) uses only the null space part log⁡p(o0∣θ)\log p(\mathbf{o}_0 \mid\theta). In the limit of infinite primary noise, Cs→∞C_s \to\infty, the column space covariance Cr→∞C_r \to\infty and log⁡p(or∣θ)\log p(\mathbf{o}_r \mid\theta) no longer depends on θ\theta, recovering the null-space likelihood. When the laser noise is finite the column space part contributes, with the singular values Σr\boldsymbol{\Sigma}_r setting the scale of its covariance.

The null space likelihood of equation (39) does not depend on the assumed primary noise level for the Lagrange and cosine-sum, because U0U_0 is set by Mˉ\bar{M} alone. The GP scales CϵC_{\epsilon} by the primary noise variance. The column space term CrC_r depends directly on CsC_s, so the wrong primary noise level gives the column space directions the wrong weight.

Simulated data

In the tests in the following sections we use two main data setups. The first is a simple single channel setup for testing the interpolators’ accuracy. The second is a simulation of the full constellation used for the full design matrix tests (§ 7), chunk size tests (§ 8) and parameter estimation tests (§ 9). The configuration files and code used to run all the tests can be found in the project repository ((Bayley et al. 2026)).

Anti-aliasing filter

All setups use the same anti-alias filter design from Staab et al. (2023), which is a Kaiser FIR filter with a passband edge at 0.1 Hz, stopband edge at 1 Hz or 2 Hz and 181 dB attenuation. This is made with lisainstrument’s make_fir_causal_kaiser ((Bayle & Hartwig 2023)) using scipy’s kaiserord ((Virtanen et al. 2020)). We use two different stopband edges, one at the Nyquist of 2 Hz and one at 1 Hz. The filter is applied to the data at the 16 Hz simulation rate and the models use the same filter resampled to the 4 Hz telemetry rate as F4F_4. We simulate the data at 16 Hz rather than the full 80 MHz on-board rate, 16 Hz is the lisainstrument default ((Staab et al. 2023)).

Single channel test

To test the three interpolators of § 3, we simulate one channel of white noise with unit variance for 4000 s with sample rate of 16 Hz. It is then filtered with the filter from § 6.1 with the stopband at 2 Hz and downsampled to 4 Hz. The interpolators then resample the noise back to 16 Hz to compare with the filtered 16 Hz data in § 7.

Full constellation

The full constellation is simulated with lisainstrument v2.1.0 ((Bayle & Hartwig 2023)) at a 16 Hz sample rate, with the noise levels defined in Table 1. All four primary noises are on, giving the full 18 columns per telemetry sample. The secondary noises are the optical metrology system (OMS) noise and the test-mass noise, all other secondary noises (ranging, angular jitter, tilt-to-length) are off. The spacecraft follow the ESA science orbits ((Martens & Joffre 2021; Bayle et al. 2025a)), so arm lengths vary with time. The lasers are locked in the “six” configuration, so the lasers are independent. The lasers have a central frequency of ν0=2.816×1014\nu_0=2.816 \times10^{14} Hz, and its noise is white. The data is filtered with the same filters described in § 6.1 and downsampled to 4 Hz. The group delay of the filter is not removed from the data as in § 4, instead the signal template is shifted by tgt_g to align with the data. The whole data segment is 500 samples or 125 s long (1000 samples for the chunk size test of § 8), and is then further split into various chunking sizes.

For parameter estimation a galactic binary signal is added before the filter stage so it passes the same filtering and down-sampling as the noise, signals are defined in § 6.4.

Signal injections

The injected signals are monochromatic galactic binaries and are injected using lisagwresponse ((Bayle et al. 2025b)). The amplitude AA, the frequency ff and the initial phase ϕ0\phi_0 are sampled uniformly from the ranges in Table 1, which are unrealistically loud, but chosen to make signals detectable with an signal-to-noise ratio (SNR) over 100 for the short segments. The remaining galactic binary parameters remain fixed for these tests. We do not perform a search, all the chains start close to the injection parameters as we are interested in the width and calibration of the posterior rather than the sampler.

Configurations

We compare five configurations in the following section, each using the 1 Hz and 2 Hz stopband edges of § 6.1, these are shown in Table 2. The full model builds MϕM_{\phi} of equation (13) at the simulation rate of 16 Hz.

Table 2. These are the TDI-∞\infty configurations we compare, and which of the two filter errors of equation (16) each handles.

ConfigurationModelFlexing filteringAliasing
Lagrange1 (Section 4.2)yesno
Cosine-sum1yesno
GP, Model 11yesno
GP, Model 22 (Section 4.3)yesyes
Full 16 Hz model–exactexact

Table 2.

Interpolation and laser noise cancellation

In TDI-∞\infty the interpolator sets the fractional delays in the design matrix MM, and as the laser noise is orders of magnitude larger than the secondary noise, small interpolation errors could have a large impact on the residual laser noise in the null space. Here we test how well the three interpolators of § 3 reproduce fractional delays, and what residual laser noise they leave.

Interpolation accuracy

In the first test we use the simplified single channel data from § 6.2, so that we can compare each interpolator’s reconstruction of the filtered data.

Figure 2 shows the spectrum of the residuals between the interpolator reconstructions and the original filtered 16 Hz data. The Lagrange and cosine-sum reconstructions show large peaks below and above the 2 Hz Nyquist frequency. These lie outside the 1 Hz LISA requirements band, but they are not by default filtered out before cancellation and so still contaminate the TDI-∞\infty null space. The GP is the most accurate interpolator between 1 and 2 Hz because its kernel carries information about the anti-alias filter that produced the data. The cosine-sum error is the largest of the three. Its coefficients are fit over the interpolator’s passband reaching only half the Nyquist, as required for LISA (Staab et al. 2025), which on the 4 Hz grid places the passband edge at 1 Hz, marked on the figure. All interpolators have a similar error between 10−410^{-4} and 10−110^{-1} Hz.

Figure 2. Frequency spectra of the difference between the 16 Hz filtered data and the same data downsampled to the 4 Hz telemetry rate and interpolated back to 16 Hz for the three interpolation methods. The dotted line at 1 Hz marks the passband edge over which the cosine-sum coefficients were fit. The grey curve is the anti-alias filter response ∣F(f)∣2|F(f)|^{2}.

Full design matrix

We test the laser noise cancellation using a noise only segment of full constellation data described in § 6.3. However in this test the secondary noises are switched off so that the projected data contains only the uncancelled primary noise. We still whiten by C~n\tilde{C}_{n} to match that used in the later tests. We build the MM matrix using the five configurations of Table 2 at the two filter stopband edges at 1 Hz and 2 Hz. Then we compute the SVD of the design matrix and find the root mean square (RMS) of the null space projection ∥U0Ty⃗∥\lVert U_{0}^{T}\vec{y}\rVert. We define the singular value threshold at 10−1410^{-14} of the largest singular value, which is the round off floor of the SVD. Appendix B shows how the null space results depend on this choice The circles in both panels of Figure 3 also show where this threshold sits. In the top panel we can see the singular values from the SVD of the ten runs. The 1 Hz runs have a smaller null space than the 2 Hz because the filter suppresses more of the 1–2 Hz band, so the whitening cut of § 5 removes these components. The full model has a smaller null space due to the 16 Hz columns giving more primary noise unknowns per measurement (§ 2). We can see that in the second panel all residuals fall below the whitened secondary noise of 1.0, except for the Lagrange and cosine-sum with a 2 Hz cutoff. This is due to the large interpolation errors seen in § 7.1. The GP however performs similarly for both cutoffs cancelling laser noise at higher frequencies near Nyquist well.

Figure 3. The singular values of the Mˉ\bar{M} matrix for the five configurations of Table 2 and two filter stop bands of 1 Hz and 2 Hz. The top panel shows the singular values plotted in reverse order. The lower panel shows the laser noise cancellation for each of these runs where the horizontal line at 1.0 refers to the secondary noise variance after whitening. The circles in both panels are the threshold used to define the null space, σcut/σmax⁡=10−14\sigma_{\rm cut}/\sigma_{\max}=10^{-14}.

Chunk sizes

The null space of Mˉ\bar{M} is found with a singular value decomposition, whose cost grows as the cube of the number of measurements, so for a realistic observation MM cannot be factorised in one piece. Following Houba et al. (2024) we split MM into chunks of ℓ\ell samples along the time axis and take the null space of each. Houba et al. (2024) use ℓ=500\ell=500 at 4 Hz with a 10 per cent overlap to keep some of the noise cross correlation lost when the covariance is split, whereas we use overlap only to recover the rows removed after the filter trim in Figure 4. In practice any chunk that trims rows would be overlapped, so in this section we compare Model 1 configurations with overlaps, and include non overlapped chunks only to show what overlapping recovers. A chunk of NyℓN_y\ell rows and NpℓN_p\ell columns gives at least (Ny−Np)ℓ=6ℓ(N_y-N_p)\ell=6\ell laser free channels, and is equal when MM has full column rank (Vallisneri et al. 2021; Houba et al. 2024).

Figure 4. Two chunks of 125 samples of the design matrix showing only sci12(t),sci21(t)\mathrm{sci}_{12}(t), \mathrm{sci}_{21}(t) against p12(t),p21(t)p_{12}(t), p_{21}(t) where each has its samples interleaved in time. The top panel shows Model 1 (§ 4.2) using Lagrange interpolation and an overlap of NtrimN_{\mathrm{trim}} and the second panel shows the same for Model 2 (§ 4.3) using the GP. The hatched regions of the boxes show both the padding of the noise columns by dd in both models and also the row trims in Model 1. The insets show a full resolution section of the matrix, where the interleaved structure is visible.

This count does not include two costs at each chunk boundary, both of which depend on the interpolator. A measurement reads laser noise at earlier times, so the columns of each chunk must extend back by a pad of dd samples, which is the largest one-way travel time between spacecraft ∼8.3\sim8.3 s ∼34\sim34 samples at 4 Hz plus the number of samples the interpolation kernel reaches before the delayed time. This gives d=57d=57 for the Lagrange with order 45 (46 taps), d=44d=44 for the cosine-sum with 22 taps, and d=34d=34 for the GP whose weights cover the whole chunk and error is absorbed by the covariance rather than padding. As chunks are factorised independently the NpdN_pd columns are new unknowns even though the previous chunk contains the same noise, and as their local measurements are in the previous chunk they cannot be cancelled in this one. Before the first chunk there is no data, so we extend the columns back by dd as well, this costs NpdN_pd unknowns rather than dropping NydN_yd rows. As well as the column padding, Model 1 (§ 4.2) applies the anti-alias filter F4F_4 with LL taps to MM, so the first Ntrim=L−1=53N_{\rm trim}=L-1=53 rows of each chunk contain its edge transient and are removed. Each filtered measurement is the sum over the previous LL measurements, the first NtrimN_{\rm trim} rows rely on measurements that are before the chunk start. The GP kernel of Model 2 (§ 4.3) contains the filter and carries the edge error in its covariance instead so Ntrim=0N_{\rm trim}=0. Neither Vallisneri et al. (2021) nor Houba et al. (2024) filter MM, so there is no row loss there.

Each boundary then costs NyNtrimN_yN_{\rm trim} rows and NpdN_pd columns and the number of laser free channels falls with every trim. Overlapping the chunks by NtrimN_{\rm trim} recovers the rows, but the overlapped rows mean that there are also extra columns, so each boundary adds Np(Ntrim+d)N_p(N_{\rm trim}+d) columns. Figure 4 shows two chunks of 125 samples of the design matrix for the two models of § 4. In Model 1 the filter is incomplete at the edge, therefore each chunk after the first is extended back by NtrimN_{\rm trim} rows so that when trimmed the filter is complete at each sample. In Model 2 there is no overlap as the GP includes edge effects in its covariance, so it only pads the columns.

Figure 5 splits a fixed 1000 sample segment into 1, 2, 4 and 8 chunks, with the same data and noise realisation for each. The counts are below 6ℓ6\ell as the null space is taken after whitening, which keeps only NwN_w of the NyℓN_y\ell rows as in § 5. The lower panel shows the optimal SNR of a galactic binary drawn from Table 1, split using equations (39) and (40) into ρ2=\rho^2=

Figure 5. A fixed 1000 sample segment split into 1, 2, 4 and 8 equal chunks, with all 18 primary noises modelled and the data and noise realisation held fixed. The top panel shows the null space size, out of a total of 24×100024 \times1000 measurements. Bottom, the optimal SNR of the injected galactic binary, where the markers are the null space only ρ0\rho_0 and the lines the reweighted ρ=(ρ02+ρr2)1/2\rho= (\rho_0^2 + \rho_r^2)^{1/2}. The shading between them is what the column space recovers. The Model 1 configurations are overlapped by NtrimN_{\mathrm{trim}}, the grey dashed line is a Lagrange interpolated run without the overlap. SNR values are for the injection of Table 1.

ρ02+ρr2with\rho_0^2 + \rho_r^2 \quad\text{with}
ρ02=∥U0Thˉ∥2,\rho_0^2 = \left\lVert U_0^{\mathsf{T}}\bar{h}\right\rVert^2,
ρr2=(UrThˉ)TCr−1(UrThˉ),(41)\rho_r^2 = \left(U_r^{\mathsf{T}}\bar{h}\right)^{\mathsf{T}} C_r^{-1}\left(U_r^{\mathsf{T}}\bar{h}\right), \tag*{(41)}

which are the null and column space contributions. Both ρ\rho and ρ0\rho_0 fall with chunk number. The gap between them is the SNR recovered by including the column space, which matters most for short chunks and its size depends on the null space threshold of Appendix B. At 125 samples Model 2 keeps around 2/3 of its single chunk SNR, where the majority comes from column space contributions, whereas the overlapped Model 1 configurations keep significantly less. The overlap recovers the trimmed rows, but the extra NpNtrimN_pN_{\mathrm{trim}} columns

it adds at each boundary mean signal information gets absorbed into the column space laser prior. Running Model 2 with the same overlap and trim recovers the same SNR as Model 1.

Each chunk is whitened and factorised independently, so the likelihood is a product over chunks and the noise covariance is block diagonal. Noise correlated on timescales longer than a chunk, i.e. at frequencies below ∼1/(ℓ Δt)\sim1/(\ell\,\Delta t), is modelled within each chunk but its correlation between chunks is lost. A complete analysis would also need to account for these correlations, which we leave to future work.

Parameter estimation tests

Sections 7 and 8 measured the residual laser noise that each interpolator leaves and the number of laser free channels that it keeps. Here we measure how they affect the posteriors of the galactic binaries of § 6.4, injected into the full constellation data of § 6.3.

Each configuration in Table 3 changes one setting from the reference, and each uses the same seed for the 200 injections and noise realisations. Each is analysed with the configurations of § 4 from § 3, using the null space likelihood equation (39) and the full likelihood of equation (40). The posteriors are sampled using emcee (Foreman-Mackey et al. 2013) using 32 walkers for 4000 steps, with 1000 burn-in steps. The configuration files and results are available on Zenodo (Bayley et al. 2026).

NameChunksf2f_2 [Hz]Change from reference
Reference1 × 5001—
Stopband 2 Hz1 × 5002stopband at Nyquist
Short chunks2 × 2501chunking
Gaps 3 × 321 × 50013 gaps of 32 samples
Gaps 32 × 31 × 500132 gaps of 3 samples

Table 3. Parameter estimation configurations. f2f_2 is the stopband edge of the anti-alias filter of § 6.1, and all runs use the noises of Table 1 unless stated.

The reference analyses a whole 500 sample segment as a single chunk with no gaps and the stopband at 1 Hz which is the best case for each interpolator. As in § 7.2 all configurations cancel below the secondary noise at 1 Hz. We include the test with the stopband edge at 2 Hz to test primarily the GP in that case, we expect the Lagrange and cosine-sum to fail due to interpolation error in § 7.1. We also repeat the chunked tests from § 8, looking at data split into two chunks of 250.

Real data will contain gaps, under the assumption that the gaps are in the telemetry samples only and not in the underlying noise, TDI-∞\infty handles these by removing rows, while standard TDI combinations lose further samples around each gap as each combination spans several delays (Burke et al. 2026). The gaps runs remove rows at the gap samples from yy, MM and the rows and columns of C~n\widetilde{C}_n in every channel, while the columns are kept. There are two cases to test: a few large gaps and many small gaps.

We check the calibration of the posteriors with p-p plots and Kolmogorov–Smirnov (KS) tests as in Romero-Shaw et al. (2020), where for calibrated posteriors the fraction of posterior samples below the injected value is uniform over the injections. For each analysis we show the smallest KS p-value of AA, ff, ϕ0\phi_0 and count it as failing when p<0.001p < 0.001. We also measure the size of the posteriors with the posterior volume defined by

V=det⁡Σ,(42)V = \sqrt{\det\Sigma}, \tag*{(42)}

where Σ\Sigma is the 3×33 \times3 sample covariance of the posterior over (A,f,ϕ0)(A, f, \phi_0).

Each of the five data setups of Table 3 is analysed with the four models, each with the null space likelihood and full likelihood with the column space, and each analysis is run on all 200 injections.

In Figure 6 summarises all the runs, with one cell per analysis, the data setups in the rows and the interpolator and likelihood in the columns. The top half of each cell is the smallest of the three KS p-values from the p-p tests of AA, ff and ϕ0\phi_0, so a cell passes only when all three parameters are calibrated. It is shaded red when p<0.001p < 0.001, which signifies a failed test. The bottom half is the median of VV over the 200 posteriors, as a ratio to the smallest median of the cells that pass.

Figure 6. Calibration and posterior size for every parameter estimation run. Rows are the configurations of Table 3 and columns the four models, each with the null-space likelihood and with the column-space term added (‘+col’). The upper half of each cell is the p-p test over the 200 injections, where we show the smallest of the KS p-values for AA, ff and ϕ0\phi_0. Cells with (p<0.001p < 0.001) fail and are red. The lower half is the median over injections of the posterior volume V=det⁡ΣV = \sqrt{\det\Sigma}, divided by the smallest median among the passing cells, so a value of 1 marks the smallest calibrated posteriors.

In the reference run all eight runs pass the p-p plot KS test, i.e. p>0.001p > 0.001. The column space term reduced VV by a factor of 1.3 for Lagrange, cosine-sum and the GP with Model 1, and about 2.5 for the GP in Model 2. This gain comes from directions just above the null space threshold, and with a larger threshold the null space posteriors reach the same size (Appendix B). The GP with Model 2 and the column space term gives the smallest posteriors, although its null space posterior is the largest of the models.

In the higher stopband test at 2 Hz, the Lagrange and cosine-sum tests fail the p-p plots, which is expected due to the interpolation error described in § 7.1. Their posterior volumes are also many orders of magnitude smaller than the reference, so the residual laser noise causes strongly overconfident posteriors. Both GP methods remain calibrated and return results consistent with the full chunk. The extra bandwidth does not make the GP posteriors worse, although the likelihood build does take longer (Figure 7), and it also adds little in this case as the signal injections are all between 0.02 and 0.05 Hz.

Figure 7. Timings of three of the runs split into the likelihood build and the sampling time for each of the interpolators.

In the test with two chunks of 250 samples, the posteriors of the Model 1 interpolators are a few times larger than the reference, and the column space recovers part of that. The GP in Model 2 has a larger null space posterior, but with the column space it is within a factor of two of the reference. We do expect some loss in information as each chunk boundary adds new unknowns, and with Model 1, rows are also trimmed.

In the two gap cases we expect loss of information due to loss of data. There are two cases: 32 short gaps of size 3 samples and 3 gaps of size 32 samples. In both cases the null space posteriors of the Model 1 interpolators increase by about 3 orders of magnitude compared to the reference, the column space brings that down to around 2 orders. Most of this difference also depends on the threshold, however in the case of gapped data, the full posteriors become overconfident before the null space reaches the same volume, so we retain some gain from using the column space (Appendix B). The GP with Model 2 and the column space term gives the smallest posteriors, which are around an order of magnitude smaller than the Lagrange equivalent in Model 1. However, its null space posterior alone is significantly larger.

In Figure 7 we show the time it took to build each of the likelihoods, including the design matrix, and the sampling time. In all cases the likelihood build dominates over the sampling time for these injections. The GP with Model 1 takes slightly longer than Lagrange or cosine-sum to build, with the GP in Model 2 taking about 2.5 times as long in the reference run.

With the column space term the GP with Model 2 gives the smallest posteriors in every run and the GP, with either model, is the only interpolator that stays valid when including information up to the Nyquist of 2 Hz. The gain of the GP and the column space is small in the runs of a single large chunk when the laser noise is much larger than the secondary noise, as is expected for LISA. However when the data is gapped, the GP can achieve an order of magnitude smaller posteriors when including the column space. How much the column space adds depends on the choice of null space threshold, for a single chunk a larger threshold recovers the same posteriors with the null space alone, whereas with gaps part of the gain remains (Appendix B).

Conclusion

In this work we extend TDI-∞\infty from Houba et al. (2024) to data that has passed through the on-board anti-alias filter and has been downsampled to the telemetry rate. The design matrix for this cannot be built at the very high rate the laser noise is sampled, so we compare two effective models at the telemetry rate (§ 4). In Model 1, used with all three interpolators, the filter is applied after the delays, following the order on the spacecraft but we remove the first L−1L - 1 rows from every chunk. In Model 2, with just the GP, the unknowns are the filtered noise samples, and the GP interpolates this filtered noise directly to the delays times. The filter is built into the kernel and the interpolation error is added to the secondary noise covariance through CϵC_\epsilon. Alongside this we also compare (i) using just the null space likelihood as in previous implementations, with (ii)keeping the column space components in § 5.

Of the three interpolators, the GP reproduces the filtered noise most accurately between 1 and 2 Hz, as its kernel is built from the filter that produced the data (§ 7). The Lagrange and cosine-sum errors are largest between 1 and 2 Hz, and when the stopband edge of the filter is moved above 1 Hz the residual laser noise rises by several orders of magnitude. On the full data simulation, all three interpolators cancel the laser noise below the secondary noise when the stopband is set to 1 Hz, but only the GP, in either model, does so when the stop band is at 2 Hz.

Splitting the design matrix into chunks costs a column pad at every boundary for all interpolators and in Model 1 the first NtrimN_{\rm trim} rows of the filter transient are dropped (§ 8). At 125 samples per chunk Model 1 has almost no null space left, and overlapping chunks recovers the samples but not the laser free channels. In contrast, the GP in Model 2 maintains much of its null space, and the column space increases the SNR by a factor of 10 at our null space threshold.

In the parameter estimation tests in § 9, we analysed 200 ‘galactic binary’-like injections in five data setups. In the reference setup we use a single 500 sample chunk with a 1 Hz stop band edge, all models give calibrated posteriors for this setup. The column space reduces the posterior volume by a factor of around 1.3 in Model 1 and 2.5 in Model 2, and the GP in Model 2 with the column space gives the smallest posteriors, although a larger null space threshold would recover most of this gain with the null space alone. With two chunks of 250 samples, the Model 1 posteriors are a few times larger than the reference, while the GP in Model 2 with the column space stays within a factor of two. All models stay calibrated with gaps, which TDI-∞\infty handles by removing rows. The Model 1 null space posteriors grew by three orders of magnitude, and including the column space reduces this to grow by two orders, some of which remains for any null space threshold. When using the GP in Model 2 with the column space, the posteriors are an order of magnitude smaller than the Lagrange and cosine-sum posteriors, and several times smaller than the GP in Model 1. This loss is far larger than one might expect from the proportion of samples removed, because each gap also prevents cancellation in the measurements within roughly a light travel time of its edges. For short segments with closely spaced gaps that affects most of the data and the impact should be much smaller for well-separated gaps and longer segments. The size of the null space loss also depends on the threshold (App. B), whereas the full posteriors only change when the threshold is raised enough to cause the posteriors to collapse. The GP takes ∼1.3\sim1.3 times longer than the Lagrange in Model 1 to build the likelihood, and the Model 2 GP takes about ∼2.5\sim2.5 times longer.

These tests were run on a simple astrophysical model with unrealistically high amplitudes and short data segments. In the future a test with more realistic astrophysical signals could be instructive. Also further testing on computing the GP design matrix using double precision would be needed as using the emulated float128 of § 4.3 is not practical for full LISA data. Further to this, for a full analysis one would have to consider the non-zero correlations between chunks. The null space threshold could also be set from the primary noise prior rather than as a fraction of the largest singular value.

In summary, we have shown that current implementations of TDI-∞\infty can be extended to filtered and downsampled telemetry data provided the on-board filter is built into the design matrix. We recommend that a LISA analysis based on TDI-∞\infty use an interpolator that remains accurate up to the Nyquist frequency and accounts for its own error, as the GP does, and keep the column space of the design matrix whenever the data are split into chunks or contain gaps.

Acknowledgements

We would like to thank Jean-Baptiste Bayle and Niklas Houba for discussions on the realistic data model and TDI-∞\infty, as well as help supplying initial code on a simplified model. We would also like to thank Christopher Messenger, Christopher Berry and John Veitch for various discussions throughout this work. Thanks to Daniel Williams for a recommendation on the title. This work was supported by grant UKRI972 awarded via the UK Space Agency.

Data Availability

Code and configuration file are available on Zenodo ((Bayley et al. 2026)).

References

Choice of the secondary noise cut

The whitening to the secondary noises as in § 5 keeps only the eigenvectors of C~n\widetilde{C}_n whose eigenvalues are above a fraction of the largest eigenvalue. We show in Figure A1 how changing this fraction affects the residual laser noise and the SNR of a signal. We set the cut to 10−1010^{-10}, the lowest value where the largest residual laser noise is a order of magnitude lower than the secondary noise for every model. the largest residual is just below the secondary noise. Higher cuts would also be acceptable, i.e. at 10−810^{-8} the largers residual is an order of magnitude lower than at 10−1010^{-10} with only a small loss in SNR.

Figure A1. Choice of the relative cut on the eigenvalues of C~n\widetilde{C}_n, for one 500 sample chunk with a 1 Hz stopband edge. Top, residual laser noise per laser-free channel in units of the secondary noise, median (solid) and maximum (dashed) over channels. Bottom, the SNR of a galactic binary for the full likelihood ρ\rho (solid) and the null space alone ρ0\rho_0 (dashed), relative to their values at the 10−1010^{-10} cut (dotted line).

Choice of singular value threshold cut

In the above sections we define the null space with a threshold of 10−1410^{-14} of the largest singular value of Mˉ\bar{M}, which is the round off floor of the SVD. Above this floor there are directions where the laser noise is cancelled well below the secondary noises but not exactly, which can be seen in the lower panel of Figure 3. The null space likelihood discards those directions, whereas the column space keeps them weighted by the primary noise prior. The null space posteriors and the gain from the column space depend on the choice of threshold.

In Figure B1 we show how the posterior volume of equation (42) changes with the threshold for a single chunk and for 32 gaps of size 3. For a single chunk, raising the threshold moves these directions into the null space and the null space posterior shrinks to the size of the full posterior. Only at thresholds above 10−710^{-7} does the GP model begin to give smaller over constrained posteriors due to un-cancelled laser noise leaking into the null space. With gaps the full posterior begins to collapse before the null space posterior reaches it, so part of the column space information cannot be recovered at any threshold. Where this happens depends on which model we are using, so the threshold would have to be chosen depending on which pipeline was used.

Figure B1. Posterior volume against the relative null space threshold, for one 500 sample chunk (top) and 32 gaps of size 3 samples (bottom). Both the Lagrange (Model 1) and GP (Model 2) use the 1 Hz stopband edge. Each injection’s volume is divided by its full likelihood volume at the 10−1410^{-14} threshold (vertical dotted line), for the null space likelihood (dashed) and the null+column (solid). Lines are the medians over the injections and bands are the 1σ1\sigma spread.

This paper has been typeset from a TeX/LaTeX file prepared by the author.

References

  1. [1]Amaro-Seoane P., et al., 2017, Laser Interferometer Space Antenna (arXiv:1702.00786 [astro-ph.IM]), doi:10.48550/arXiv.1702.00786, http://arxiv.org/abs/1702.00786
  2. [2]Armstrong J. W., Estabrook F. B., Tinto M., 1999, The Astrophysical Journal, 527, 814
  3. [3]Baghi Q., et al., 2026, LISA science ground segment conventions (arXiv:2603.22377 [astro-ph.IM]), doi:10.48550/arXiv.2603.22377, http://arxiv.org/abs/2603.22377
  4. [4]Bayle J.-B., Hartwig O., 2023, Physical Review D, 107, 083019
  5. [5]Bayle J.-B., Lilley M., Petiteau A., Halloin H., 2019, Physical Review D, 99, 084023
  6. [6]Bayle J.-B., Baghi Q., Renzini A., Le Jeune M., 2025b, LISA GW Response, doi:10.5281/zenodo.17238548, https://doi.org/10.5281/zenodo.17238548
  7. [7]Bayle J.-B., Hees A., Lilley M., Le Poncin-Lafitte C., Martens W., Joffre E., 2025a, LISA Orbits, doi:10.5281/zenodo.17296456, https://doi.org/10.5281/zenodo.17296456
  8. [8]Bayley J., Woan G., Burke O., 2026, Configuration files, code and results for “TDI-∞ and beyond”, doi:10.5281/zenodo.23801536, https://doi.org/10.5281/zenodo.23801536
  9. [9]Burke O., Muratore M., Woan G., 2026, Phys. Rev. Applied, 25, 034041
  10. [10]Colpi M., et al., 2024, LISA Definition Study Report (arXiv:2402.07571 [astro-ph.CO]), doi:10.48550/arXiv.2402.07571, http://arxiv.org/abs/2402.07571
  11. [11]Foreman-Mackey D., Hogg D. W., Lang D., Goodman J., 2013, PASP, 125, 306
  12. [12]Harer S., Staab M., Halloin H., 2025, Mitigation of the Flexing-Filtering Effect in Time-Delay Interferometry (arXiv:2506.04316 [astro-ph.IM]), doi:10.48550/arXiv.2506.04316, http://arxiv.org/abs/2506.04316
  13. [13]Hartwig O., Bayle J.-B., 2021, Physical Review D, 103, 123027
  14. [14]Houba N., Delchambre S., Hechenblaikner G., Ziegler T., Fichter W., 2023, Classical and Quantum Gravity, 40, 107001
  15. [15]Houba N., Bayle J.-B., Vallisneri M., 2024, Robust Bayesian inference with gapped LISA data using all-in-one TDI-$\infty$ (arXiv:2412.20793 [astro-ph.IM]), doi:10.48550/arXiv.2412.20793, http://arxiv.org/abs/2412.20793
  16. [16]Johansson F., 2026, flintlib/python-flint: Python bindings for Flint and Arb, https://github.com/flintlib/python-flint/
  17. [17]Martens W., Joffre E., 2021, The Journal of the Astronautical Sciences, 68, 402
  18. [18]Moore C. J., Berry C. P. L., Chua A. J. K., Gair J. R., 2016, Physical Review D, 93, 064001
  19. [19]Rasmussen C. E., Williams C. K. I., 2005, Gaussian Processes for Machine Learning. Adaptive Computation and Machine Learning series, MIT Press, https://mitpress.mit.edu/9780262182539/gaussian-processes-for-machine-learning/
  20. [20]Romano J. D., Woan G., 2006, Physical Review D, 73, 102001
  21. [21]Romero-Shaw I. M., et al., 2020, Monthly Notices of the Royal Astronomical Society, 499, 3295
  22. [22]Shaddock D. A., Ware B., Spero R. E., Vallisneri M., 2004, Physical Review D, 70, 081101

Paper details

vlnc:W_95kr6rxm
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents