Unifying Heterogeneous Dissipativity for Distributed Power-System Stability Analysis
Abstract
Compositional dissipativity is attractive for large-scale interconnected systems, but its application to modern heterogeneous power systems is limited by conservative descriptions of nodal dissipativity and inefficient distributed implementation. This paper introduces a common first-order dynamic lifting of the physical voltage-current port, providing an enriched dissipativity representation that captures complementary frequency-dependent energy behavior while preserving network composability. The resulting representation accommodates heterogeneous power system buses within a unified dissipativity description and enables less conservative compositional stability analysis. A centralized stability-certification problem is then formulated and solved through a dual-guided column-generation scheme. Its matrix dual reveals the network-critical dissipation direction, which guides parallel local certificate generation toward the current system bottleneck. This leads to a distributed Network-Critical Margin Exchange (NCME) method with early stability certification. Case studies demonstrate substantially reduced conservatism of the dynamic-port formulation and improved computational and communication scalability of NCME for heterogeneous power systems.
Introduction
Power system stability analysis is fundamental to the secure operation of interconnected grids [1, 2]. With the increasing penetration of renewable generation and power-electronic interfaces, modern power systems are becoming larger, more heterogeneous, and dynamically more complex [2, 3]. Synchronous machines, grid-forming and grid-following converters, dynamic and static loads, and diverse control architectures exhibit substantially different dynamics, operating time scales, and terminal causalities. These developments call for stability-analysis methods that can accommodate heterogeneous nodal behavior while remaining scalable to large networks.
Dissipativity provides a natural framework for this purpose because subsystem properties can be characterized locally through storage functions and supply rates, while system-level stability follows from compatibility of the local dissipative properties under interconnection [4, 5, 6, 7]. Passivity is particularly attractive for distributed analysis and has been widely used in power systems [8, 9, 10, 11, 12]. However, a prescribed passivity relation can be restrictive because heterogeneous devices are difficult to be passive over all frequency ranges under the same input–output ports [13, 14]. Generalized formulations, including differential passivity [15, 16, 17], matrix-valued indices [18, 19], and equilibrium-free dissipativity [20, 21], extend the applicability, but these methods still rely on device-dependent supply structures. Consequently, a dissipativity description suitable for one device class may fail to fully exploit the dissipative properties of another.
A more flexible alternative is to enlarge the supply-rate description itself. Dynamic supply rates and related integral-quadratic-constraint formulations introduce stable dynamic operators into port variables, allowing frequency-dependent behavior to be represented within a common quadratic form [22, 23, 24, 25, 26]. This provides a promising route for retaining the native input–output variables while enriching the dissipativity description of heterogeneous buses. However, the additional freedom requires the local supply matrices to be coordinated through a network-level matrix inequality, leading to a coupled semidefinite program. Existing compositional-certification methods address this coupling through dual decomposition or distributed optimization, including ADMM-based approaches [21, 27, 28, 29]. While systematic, these generic methods do not explicitly exploit the physical structure of the network dissipation bottleneck, leading to the limited application in large-scale power systems.
To address these limitations, this paper enriches the dissipativity representation of heterogeneous power-system buses through a unified first-order dynamic lifting of the physical voltage–current port. The resulting dynamic supply rate captures complementary frequency-dependent terminal behavior while retaining a common network composition map. Building on this representation, the compositional stability-certification problem is further decomposed through dual-guided column generation, where the matrix dual reveals the network-critical dissipation direction and coordinates parallel local certificate searches. The main contributions are summarized as follows.
Enhanced dissipativity representation for heterogeneous power-system buses. A common first-order dynamic supply rate lifting is introduced at the physical voltage–current port to capture complementary frequency-dependent dissipative behavior within a composable supply representation. This enriched representation accommodates heterogeneous dynamic and algebraic buses under a unified dissipativity description, allowing their available dissipative properties to be exploited more fully and thereby reducing the conservatism and extending the applicability of compositional power-system stability analysis.
Network-critical-direction-guided distributed stability certification. The centralized compositional certification problem is decomposed through dual-guided column generation. The resulting matrix dual identifies the network-critical dissipation direction and translates the system-level bottleneck into informative local weightings for certificate generation. This physics-informed coordination enables dis-
tributed stability certification with certified bounds and early termination, improving the computational and communication scalability of stability analysis for large heterogeneous power systems.
The remainder of this paper is organized as follows. Section II introduces the preliminaries and power-system model. Section III develops the unified dynamic dissipativity port and the compositional stability criterion. Section IV formulates convex local dissipativity certificates and the centralized stability-verification problem. Section V presents the dual interpretation and the distributed NCME method. Section VI reports case studies, and Section VII concludes the paper.
Notation: and denote the -dimensional real vector space and the set of real symmetric matrices, respectively. For , () means that is positive semidefinite (positive definite). and denote the -dimension identity matrix and zero matrix, respectively, and is the th canonical basis vector. The operators , , and denote column stacking, block-diagonal concatenation, and the Kronecker product. For matrices and of compatible dimensions, denotes the Frobenius inner product, while and denote the nullspace and range of . For and ,
denotes the largest generalized eigenvalue of . For a set , denotes its convex hull.
Modeling and Preliminaries
Dissipativity and Passivity
Consider a dynamical system:
where state , input , and output . The map is locally Lipschitz, and is continuous. Without loss of generality, the origin is assumed to be an equilibrium of (1). That is, , . Denote the system supply-rate signal as . The definition of dissipativity is shown below.
Definition 1 (Dissipativity [30]). The system (1) is dissipative with respect to a supply rate if there exists a positive semidefinite (p.s.d.) function , referred to as the storage function, s.t. for all initial conditions , all admissible inputs and all , the following inequality holds
For a continuously differentiable storage function, Definition 1 shows that system (1) is dissipative with respect to a supply rate if every admissible trajectory satisfies . A widely used class of supply rates is the quadratic form , , also called QSR-dissipativity, where is called the supply matrix. Passivity and strict passivity [31] are particular choices of , that is
Differential-passivity [15, 17, 18] formulations enrich the same idea with derivative information. Representative output-differential passivity (ODP) and input-differential passivity (IDP) structures can be written schematically as , and , , respectively.
Structure-Preserving DAE modeling of power systems
Consider a structure-preserving power system composed of buses and transmission lines connecting them. It can be represented by an undirected graph , where and denote the sets of buses and transmission lines, respectively. At bus , define the terminal voltage and current as
where the subscript and denotes the -axis and -axis components of the port voltage or port current , respectively. is defined positive from the network into the local bus subsystem.
The bus set is partitioned as , , where contains buses with internal dynamic states and contains static or purely algebraic buses. For each , the local dynamics are described in the general nonlinear form
where is the internal state, is the dimension of the dynamic state of bus , and are terminal input and output variables. For each , the corresponding static relation is written as
Depending on the physical device and its control architecture, either terminal voltage or terminal current may serve as the natural input variable. Thus, dynamic and static buses may admit either of the causal assignments or . Let and . With the bus-admittance matrix and the power flow relationship , Kirchhoff’s current law then gives
where is the bus-wise real representation of . The network coupling can be represented abstractly as a static relation between the network interconnection variables, where and under the feedback interconnection. Combining the bus dynamics with this network relation yields the feedback-interconnected power-system model depicted in Figure 1.
Figure 1. Feedback interconnected power system model
Collecting all internal dynamic states of the buses into . Let , , and . The whole power system can be modeled as
Definition 2. is an operating equilibrium of (6) if , . The corresponding variable at the operating equilibrium is denoted by the superscript .
For the subsequent stability analysis, deviation coordinates are introduced for all state and terminal variables, that is , and . For notational simplicity, the prefix is omitted hereafter. Hence the prescribed equilibrium is represented by the origin in all subsequent analysis.
The alternative input–output orientations are useful for device-level modeling but will not be imposed on the compositional analysis developed in this paper. Instead, all buses are represented through the common physical port , irrespective of their internal causality. Let select the voltage coordinates associated with bus , that is . The physical port of each bus can consequently be expressed directly from the network voltage vector as and , or equivalently,
Using the common physical port , the explicit input–output orientation of each bus is no longer required in the subsequent compositional analysis. We denote the corresponding nonlinear local bus behavior compactly by
where is induced by the original bus model together with the appropriate voltage–current causality. The collection of (7) and (8) constitutes a structure-preserving nonlinear DAE description of the interconnected system in the common physical-port coordinates.
Heterogeneity of Power System Buses
Heterogeneous buses can differ substantially in dynamic behavior and causal orientations, leading to different descriptions of dissipativity in natural physical ports. Representative bus models include synchronous generators, grid-forming converters with virtual-synchronous-machine or droop-type controls, phase-locked loop (PLL)-synchronized grid-following converters, dynamic loads, static loads, and purely algebraic interconnection buses. Detailed nonlinear models and their transformations to common voltage–current variables have been established in existing studies. Here we follow these bus models and summarize the structural features relevant to the dissipativity analysis in Table 1.
| Device class | Temporal characteristics | Dissipativity description | Dissipativity coordinates | Physical-port causality |
| Synchronous generator (SG) [9], [13], [15] | Electromechanical dynamics | ODP/passivity-type | Power/voltage-angle variables | |
| Grid-forming converter with virtual synchronous generator (VSG) control [16], [21] | Outer-loop dynamics | ODP-type | Power/voltage-angle variables | |
| Grid-forming converter with conventional droop (CD) control [16], [21], [32] | Outer-loop dynamics | ODP-type | Power/voltage-angle variables | |
| Grid-forming converter with quadratic droop (QD) control [15], [18], [33] | Outer-loop dynamics | ODP-type | Power/voltage-angle variables | |
| PLL-synchronized grid-following converter (GFL) [17], [21] | Synchronization and power-control dynamics | IDP-type | Power/voltage-angle variables | |
| ZIP load [12], [21] | Static | Static QSR | Voltage–current variables | |
| Constant-impedance load [12], [21] | Static | Static QSR | Voltage–current variables | |
| Intermediate / junction bus [21] | Static | Static QSR | Voltage–current variables | |
| Constant-voltage source [21] | Static | Static QSR | Voltage–current variables |
Table 1. Representative heterogeneous power-system nodes and their conventional dissipativity descriptions.
In particular, the heterogeneity of power-system buses is reflected mainly in their frequency-dependent dissipative characteristics and port causality. Synchronous generators, for example, may exhibit low-frequency nonpassivity but become passive at higher frequencies at the physical voltage–current port [13], which motivates output-differential or negative-imaginary descriptions [9, 15]. By contrast, static network elements and loads have no internal dynamics and are naturally characterized by static quadratic voltage–current relations. Port causality also differs across dynamic devices: PLL-based grid-following converters typically admit a voltage-input/current-output description, whereas grid-forming converters are more naturally represented with the opposite orientation [17, 21]. These differences make a single conventional passivity structure difficult to apply uniformly without added conservatism or structural restrictions.
Power-System Stability Analysis via a Unified Dynamic Dissipativity Port
This section develops a unified dynamic dissipativity description for heterogeneous power-system buses and establishes a compositional stability criterion for the interconnected power system.
Unified Dynamic Dissipativity Port
To unify the dissipativity description of heterogeneous buses, we augment the native physical port with a fixed first-order dynamic lifting:
where is the local filtered port and is the prescribed cutoff frequency. Under zero initial conditions, the corresponding transfer representation is as follows.
The local dynamic supply rate is then defined as where is the local supply rate matrix. The scalar filters are common to all buses, ensuring compatibility with the static network interconnection. To establish the port relation in the time domain, a common filtered network voltage is introduced as , and the local filtered physical-port variable is . The local and network dynamical ports are initialized consistently, i.e., .
Taking as the common dynamic network coordinate and as the corresponding static port projection. According to the network relation (7), it follows that
Thus, the dynamic augmentation preserves a common network composition map, allowing heterogeneous nodal supply rates to be expressed on the same dynamic network coordinate.
The proposed dynamic port (9) admits an equivalent interpretation in terms of low- and high-frequency port:
Accordingly, the dynamic supply rate admits the equivalent quadratic representation , . Under zero initial conditions, the two components of satisfy
The corresponding transfer functions form a complementary pair of low-pass and high-pass filters, with and a common cutoff frequency . The full symmetric supply matrix can equivalently characterize the dissipative properties of both frequency components and their cross-frequency couplings. Furthermore, this dynamic lifting is capable of including static quadratic supplies and filtered versions of ODP and IDP supplies. The relation is described in Appendix A.
Compositional Stability with Unified Dynamic Dissipativity
Consider the interconnected power-system (6). Combining (6) with the proposed unified dynamic port (9), and defining ( for ), the augmented interconnected system satisfies
Under the augmented dynamic port , each bus is locally dissipative with respect to the quadratic supply matrix if there exists a continuously differentiable p.s.d. storage function , satisfying
along every admissible local trajectory of the augmented bus model. For any collection of local dissipativity descriptions , define the aggregate storage and the aggregate supply matrix . Since , summing the local dissipation inequalities gives
Definition 3 (q-detectability). The augmented interconnected system (13) is locally q-detectable at the equilibrium if there exists a neighborhood of the equilibrium on the consistent state manifold such that every admissible trajectory of (13) that remains in for all and satisfies converges to the equilibrium.
Theorem 1 (Compositional stability criterion). Consider the interconnected power-system (13) with an equilibrium at the origin. Suppose in a neighborhood of the equilibrium, the consistent states form a smooth invariant manifold on which the DAE induces a locally unique smooth vector field. Assume each bus admits a local dynamic dissipativity description (14) and is locally positive definite on . Then:
If , the equilibrium is locally Lyapunov stable.
If the interconnected system (13) is locally q-detectable and there exist a matrix and a scalar such that
then the equilibrium is locally asymptotically stable.
Proof. According to (15), under . Since is locally positive definite on the consistent state manifold, it constitutes a local Lyapunov function for the augmented interconnected system, which establishes local Lyapunov stability. Under (16), . Choose a sufficiently small compact sublevel set of on contained in the neighborhood where the above conditions hold. Since , this set is positively invariant. By the invariance principle, every trajectory in this set approaches the largest invariant subset of . Since and , implies . Local -detectability then implies that the only invariant limiting behavior compatible with is convergence to the equilibrium. Hence the equilibrium is locally asymptotically stable.
Since the dynamic filters are auxiliary and do not alter the physical dynamics, initializing them consistently transfers the stability conclusion to the original nonlinear system (6). Theorem 1 consequently reduces stability analysis to finding locally realizable matrices compatible through the network inequality. The next section formalizes this search.
Stability Verification via Convex Dissipativity Certificates
Local Dissipativity Certification
For each bus , fix a local domain containing the equilibrium and let be a convex cone of continuously differentiable, p.s.d. storage functions. Define the local dissipativity-certificate set
The dissipation inequality is required along all admissible local trajectories in the prescribed domain. Since both the storage-function class and the dissipation inequality are closed under nonnegative linear combinations, is a convex cone and is generally unbounded. For the optimization problems developed below, we restrict the scale of the certificates by a prescribed bounded convex normalization set containing the origin in its relative interior, and define
The normalization set is chosen such that is nonempty and compact. Since contains a neighborhood of the origin in the certificate space, every feasible ray of admits a scaled representative in . Thus, the normalization bounds only the certificate magnitude without altering the underlying local dissipativity condition. Its particular choice determines the numerical scale of the compatibility margin introduced below.
Centralized Compositional Stability Verification
Theorem 1 reduces system-wide stability verification to the search for locally admissible dissipativity certificates whose supply matrices are compatible through the network condition. Using the compact convex certificate sets defined in (18), this search can be formulated as follows.
Corollary 1 (Centralized compositional stability verification). Consider the interconnected power-system (13) and let be fixed. Define the centralized stability verification problem
If and the associated aggregate storage is locally positive definite, then the equilibrium is locally Lyapunov stable. In addition, if the system (13) is locally -detectable, then the equilibrium is locally asymptotically stable.
The value of depends on the normalization set used in defining and should therefore be interpreted as a certificate-compatibility margin rather than a physical stability margin.
For polynomial local dynamics, the functional certificate search in (19) can be realized using standard sum-of-squares (SOS) techniques [28, 34, 35]. With prescribed polynomial degrees for the storage functions and SOS multipliers, the resulting nonlinear centralized stability verification problem admits a finite-dimensional semidefinite programming (SDP) formulation.
Linear-System Specialization
For linear system analysis, the compositional stability certificate problem (19) admits an explicit finite-dimensional SDP realization. Linearizing the local bus model around the prescribed operating equilibrium yields
With the filter state included in , the augmented local model can be written as
where
Let . The descriptor dynamics impose the linear constraint , where . Let be any basis of . For the quadratic storage , , the local dissipation inequality (14) is ensured by the following LMI
Accordingly, the local dissipativity certificate set in (18) can be specialized as
with prescribed constants . Replacing the general certificate sets in Corollary 1 by yields a finite-dimensional SDP with the network compatibility variable .
Assume that the interconnected linearized DAE (21) is regular and impulse-free and admits the finite consistent realization
Then the aggregate quadratic storage is , where . Hence verifies positive definiteness of the aggregate quadratic storage required by Corollary 1.
Physics-Informed Distributed Stability Verification
Network-Critical Dissipation Direction
To enable a distributed implementation of the centralized stability verification problem (19), we first examine its dual structure. Introducing a dual matrix associated with the network compatibility constraint. The Lagrangian is
Maximization over the unrestricted requires . Define the compact dual set . For , the local minimum support value is
Since the local certificate sets are nonempty, compact, and convex, and the network constraint admits a strict feasible point for sufficiently negative , strong duality gives
The optimal dual matrix admits a direct network-level interpretation.
Proposition 1 (Network-Critical Dual Weighting). Let , , and be primal and dual optimal solutions of (19) and (25), respectively. Define and . Then
Thus, , and every nonzero vector in is a generalized eigenvector of associated with .
Proof. Complementary slackness gives . Since and , it follows that . For fixed , the largest feasible satisfying is , which yields (26).
If the active maximum eigenvalue is simple and spans , the normalization gives . For a multiple active eigenvalue, instead provides a positive-semidefinite weighting over the critical subspace and need not have full support on that subspace. For any nonzero network coordinate , the generalized Rayleigh quotient measures the normalized aggregate supply along the network direction . At bus , in the simple-eigenvalue case, the corresponding local weighting is
Thus, transfers the global network-critical dissipation information to the local augmented port and weights local certificate improvement according to its relevance to the current network bottleneck. This matrix-valued weighting provides the coordination signal used in the distributed certificate-exchange procedure developed next.
Distributed Network-Critical Margin Exchange (NCME)
We now exploit the dual characterization above to solve the centralized verification problem through iterative exchange between the network and individual buses. Algorithm 1 summarizes the procedure.
Initialization. Each bus initializes a finite feasible certificate library containing the zero certificate. Unless otherwise specified, . To obtain an informative initial atom, the network selects , and broadcasts .
Restricted master. At iteration , let where is the current size of the local certificate library. Define . The network solves the restricted master problem
Whenever the certificates satisfy the storage condition of Corollary 1 with , local Lyapunov stability is certified without requiring convergence of the optimization. Local -detectability may be checked separately when asymptotic stability is desired.
Network-critical pricing. Let be an optimal dual matrix of (28). The network broadcasts and each bus independently solves the local pricing problem (24) and obtains and . Exact pricing gives the current dual upper bound, and its best-so-far value is retained as
The newly priced certificate is added to the library as .
Termination. The procedure terminates when either a storage-qualified positive-margin certificate is obtained or . In the latter case, the centralized margin is resolved within tolerance, and the absence of a strict certificate is reported as not certified.
Algorithm 1 Network-Critical Margin Exchange (NCME)
Require: Local sets , maps , , tolerances .
Initialize , , , .
Set ; broadcast , and augment each by one parallel pricing solve.
for do
Solve (28) over , obtain , , and .
if the appropriate complete certification test of § 4 holds then
return certified stable.
end if
Broadcast ; each bus solve (24) in parallel and returns and the local pricing value.
Compute and through (29).
if then
return margin resolved; stability not certified
end if
Add to its certificate library.
end for
Proposition 2 (Certified bounds and convergence). Suppose that each is nonempty, compact, and convex, the restricted-master and local pricing problems are solved exactly. Then for all , with nondecreasing and nonincreasing. Moreover, for the iteration continued without early termination, , , and hence .*
Proof. See Appendix B.
Case Studies
Heterogeneous Four-Bus Benchmark
We first consider the heterogeneous four-bus benchmark shown in Figure 2, consisting of an SG, a QD-GFM converter, a PLL-GFL converter, and a static ZIP load. To assess the conservatism reduction in stability analysis enabled by the dynamic port, the normalized QD gain and PLL reactive-voltage coupling gain are varied over a two-dimensional parameter grid. Finite generalized eigenvalues of the complete structure-preserving DAE are used as the stability reference. Figure 3 compares centralized certificates obtained with the native static port and the filtered dynamic port . The static formulation certifies 63.9% of the eigenvalue-stable operating points, whereas the dynamic formulation certifies 99.8%, with no unstable point certified. The same dynamic certification rate is obtained for p.u., indicating low sensitivity to the cutoff-frequency selection. These results show that the dynamic port substantially reduces the conservatism of the corresponding compositional stability analysis.
Figure 2. Topology of the heterogeneous four-bus system.

Figure 3. Centralized stability certification of the four-bus benchmark using (a) the static port and (b) the dynamic port .
To further explain how the proposed dynamic port improves stability certification, two representative operating points, A and B, are selected from Figure 3. The static- and dynamic-port dissipativity certificate families, denoted by and , are projected onto a common two-dimensional plane, as shown in Figure 4. Using fixed common projection weights and , define as the aggregate dissipative support along the selected network-critical direction and , where measures the deviation of the dynamic supply matrix from the static-port structure and thus captures the additional low–high-frequency dissipativity freedom introduced by the dynamic lifting. For each point , membership in the projected dissipativity-feasible region is determined by whether there exists a certificate in the normalized set (for the dynamic port) or (for the static port) satisfying and . The network-certified subset is obtained analogously by additionally imposing the complete stability-certification conditions. For visualization, the coordinates are transformed as and with . The static family lies on , reflecting the absence of additional low–high-frequency dissipativity freedom in the static-port description, whereas the dynamic port expands the feasible dissipativity region away from this line. At point A, the static family already intersects the network-certified region. At point B, however, certification is achieved only through the additional dissipativity freedom provided by the dynamic port, illustrating how the enriched representation reduces the conservatism of static-port stability certification.
Figure 4. Projected dissipativity families and network certification at A and B. (a), (b) Global views; (c), (d) certification details.
We next examine the NCME procedure using one certifiable stable point and one eigenvalue-unstable point. As shown in Figure 5, the NCME lower and best-so-far upper bounds approach the centralized SDP result. For the stable point, the normalized certification test is first satisfied at , well before full bound convergence. For the unstable point, the centralized compatibility optimum is numerically zero, no valid certificate is obtained, and NCME terminates when the prescribed gap tolerance is reached at . This
Figure 5. NCME convergence at representative certifiable-stable (a) and eigenvalue-unstable (b) operating points of the four-bus benchmark confirms both convergence to the centralized result and early stability certification when a valid certificate exists.
To assess distributed certification efficiency, NCME is compared with a feasibility-based ADMM solver at three stable operating points representing deep-interior, intermediate-margin, and near-boundary conditions, respectively referred to as Deep, Middle, and Near. Both use identical local certificate sets and scaling bounds, a common target equal to 1% of the centralized dynamic-port optimal margin, and the same normalized certificate audit. Each method stops at the first passing certificate or the 500-round budget. Table II reports the corresponding timing and communication costs across ten runs per point. Overall, NCME achieves substantially lower coordination, computation, and communication costs than ADMM across the tested operating points.
| Point | Method | Succ. | Rounds | Wall-clock time (s) | Ideal-parallel time (s) | Comm. |
| Deep | NCME | 10/10 | 13 | 4.14 | 1.78 | 5840 |
| ADMM | 10/10 | 55 | 15.53 | 6.37 | 21065 | |
| Middle | NCME | 10/10 | 15 | 4.69 | 2.03 | 6606 |
| ADMM | 10/10 | 66 | 18.57 | 7.80 | 25278 | |
| Near | NCME | 10/10 | 28 | 9.07 | 4.19 | 11585 |
| ADMM | 0/10 | 500^a | 145.11^a | 61.22^a | 191,500^a |
Table II. NCME AND ADMM CERTIFICATION PERFORMANCE ON THE FOUR-BUS BENCHMARK. Budget exhausted without attaining the prescribed target.
Modified IEEE 118-Bus System
To evaluate the proposed framework on a large-scale heterogeneous system, a modified IEEE 118-Bus benchmark is constructed on the original topology [36]. As illustrated in Figure 6, the system contains 34 synchronous generators (SGs), 15 CD-GFM converters, 14 QD-GFM converters, and 14 PLL-GFL converters, together with static ZIP loads and algebraic junction buses. To span a broad operating range, the uniform load scale is varied from 0.5 to 1.9, while a common damping scale is applied to the nominal damping coefficients of all dynamic devices. For each , the critical is located by finite-eigenvalue analysis, the centralized
Figure 6. The structure of the modified IEEE 118-Bus benchmark.
static-port and dynamic-port certificates, respectively. Figure 7(a) shows the resulting boundaries. The static-port condition requires substantially larger damping throughout the loading range, whereas the dynamic-port boundary lies much closer to the finite-eigenvalue stability limit, demonstrating a marked reduction in conservatism at large scale. We further examine the large-scale behavior of NCME at the representative operating point and . Figure 7(b) shows that the restricted-master lower bound and the pricing upper bound converge toward the centralized optimum, while the normalized stability certificate is first obtained at stage , well before full margin convergence.
Figure 7. Compositional stability analysis of the modified IEEE 118-bus benchmark. (a) stability and certification boundaries; (b) NCME bounds and first certification at operating point N.
To expose the underlying exchange mechanism, define the restricted support , the pricing improvement , and the aggregate unresolved pricing improvement . measures the total improvement still available from the full local certificate sets relative to the current libraries under the critical weighting . As shown in Figure 8(a), decreases by more than three orders of magnitude before certification, confirming that successive NCME exchanges progressively exhaust the local certificate improvements not represented by the restricted libraries. Figure 8(b) further decomposes by device class. The unresolved pricing improvement is initially almost entirely associated with SG buses, but progressively redistributes toward GFM, PLL-GFL, and static/algebraic buses as the certificate libraries are enriched. Hence, NCME does not repeatedly target a predetermined subset of devices. Instead, the network-critical weighting adaptively steers certificate generation toward the local sets that offer the largest remaining pricing improvement.
Figure 8. NCME convergence and certificate-enrichment process in the modified IEEE 118-Bus system. (a) Aggregate unresolved pricing improvement. (b) Device-class composition of the pricing improvement.
Nonlinear Scalability and Computational Efficiency
To evaluate the scalability of NCME beyond the power-system specialization, we consider randomly generated networks of nonlinear polynomial subsystems for which the local dissipativity certificates admit SOS representations. For each network size , ten matched random systems are generated and solved by NCME and an ADMM-based compositional solver under the same local certificate model and numerical certification tolerance. A direct global SOS formulation is also evaluated for , beyond which its computational cost becomes prohibitive. For the distributed methods, the reported computation time is the ideal node-parallel execution time, whereas the communication metric counts the cumulative transmitted double-precision scalars. The results are shown in Figure 9, where the solid lines denote the mean and shaded regions indicate the min–max range of the random systems. The results show that the direct global SOS search increases rapidly with , while both distributed methods avoid the growth of the monolithic nonlinear certificate problem by retaining node-local certificate searches. NCME further requires consistently less ideal-parallel computation than ADMM and reduces the cumulative communication payload by more than one order of magnitude over most tested network sizes. The advantage becomes more pronounced in communication as increases, reflecting that NCME exchanges network-critical certificate information rather than repeatedly enforcing full consensus. These results demonstrate that the proposed exchange mechanism preserves the scalability of compositional nonlinear certification while substantially reducing the distributed coordination burden.
Figure 9. Scalability on randomized nonlinear systems. (a) Certification time. (b) Cumulative communication payload.
Conclusion
This paper develops a compositional stability-analysis framework for heterogeneous power systems that combines a unified dynamic dissipativity representation with scalable distributed stability certification. A common first-order dynamic lifting of the physical voltage–current port enriches the local supply-rate description with complementary frequency-dependent information, enabling heterogeneous buses to be represented within a common network-composable form and substantially reducing the conservatism of stability certificates. The resulting compositional certification problem was further solved through dual-guided column generation. Its matrix dual identifies the network-critical dissipation direction, which provides a physically meaningful coordination signal for parallel local certificate generation in the proposed NCME method. The resulting lower–upper bound mechanism enables distributed certification and stability verification before full optimization convergence. Case studies on heterogeneous power-system benchmarks and nonlinear networks demonstrate the improved certification capability of the dynamic representation and the computational and communication scalability of NCME. Future work will focus on identifying system-specific dynamic supply rates that best capture available dissipativity, together with data-driven extensions for online stability assessment.
Conventional Dissipativity in the Dynamic Port
Let where maps the physical port to the prescribed input–output ordering. Define and such that , . First, consider the conventional static quadratic supply rate . For the proposed dynamic port , this supply rate is represented exactly as
Next, we consider differential passivity. The conventional output-differential passivity (ODP) supply rate is , , whereas the input-differential passivity (IDP) supply rate is , . The finite-dimensional dynamic lifting provides filtered derivatives of the input and output as
Accordingly, define the filtered ODP and IDP supply rates as and , respectively. For the filtered ODP supply, define
Then
Similarly, for the filtered IDP supply, define
It follows that
Under zero filter initial conditions, we have and , where . For each fixed frequency, . Thus, the filtered derivatives approach the ideal derivatives for sufficiently regular signals as the cutoff frequency increases, and the filtered ODP and IDP supplies approach their conventional differential counterparts. This limiting relation does not, by itself, imply preservation of dissipativity for any finite cutoff frequency.
Overall, the proposed dynamic port contains static QSR descriptions exactly and admits filtered counterparts of the conventional ODP and IDP structures within the same quadratic supply-rate form .
Proof of Proposition 2
Proof. The bounds and monotonicity follow directly from restriction, weak duality, and nested certificate libraries. Since is nondecreasing and bounded above by , let . Define and . Let denote the restricted dual objective at iteration , so that . By compactness of , and all are uniformly Lipschitz continuous on .
Select a subsequence . Uniform Lipschitz continuity gives . Since and is nondecreasing, it follows that . Exact pricing at generates satisfying . By uniform continuity of on the compact feasible sets, . Since all pricing atoms are retained, . Passing to the limit yields . Together with , this proves .
Moreover, along the same subsequence, . Since is nonincreasing and satisfies , it follows that . Consequently, .
References
- [1]P. Kundur, Power System Stability and Control. New York, NY, USA: McGraw-Hill, 1994.
- [2]N. Hatziargyriou, J. Milanovic, C. Rahmann, V. Ajjarapu, C. Canizares, I. Erlich, D. Hill, I. Hiskens, I. Kamwa, B. Pal, P. Pourbeik, J. Sanchez-Gasca, A. Stankovic, T. V. Cutsem, V. Vittal, and C. Vournas, “Definition and classification of power system stability—revised & extended,” IEEE Transactions on Power Systems, vol. 36, no. 4, pp. 3271–3281, 2021.DOI
- [3]A. Tayebi, D. Grob, A. Anta, F. Kupzog, and F. Dörfler, “Frequency stability of synchronous machines and grid-forming power converters,” IEEE Journal of Emerging and Selected Topics in Power Electronics, vol. 8, no. 2, pp. 1004–1018, 2020.
- [4]J. C. Willems, “Dissipative dynamical systems—part 1: General theory,” Archive for Rational Mechanics and Analysis, vol. 45, pp. 321–351, 1972.
- [5]——, “Dissipative dynamical systems—part ii: Linear systems with quadratic supply rates,” Archive for Rational Mechanics and Analysis, vol. 45, pp. 352–393, 1972.
- [6]D. J. Hill and P. J. Moylan, “The stability of nonlinear dissipative systems,” IEEE Transactions on Automatic Control, vol. 21, no. 5, pp. 708–711, 1976.DOI
- [7]M. Arcak, C. Meissen, and A. Packard, Networks of Dissipative Systems: Compositional Certification of Stability, Performance, and Safety. Cham, Switzerland: Springer, 2016.
- [8]R. Ortega, A. Astolfi, and G. Espinosa-Perez, “A passivation approach to power systems stabilization,” in IFAC Proceedings Volumes, vol. 31, no. 17, 1998, pp. 309–313.DOI
- [9]M. Khodabakhshloo, E. L. Ratnam, and I. R. Petersen, “Negative imaginary and passivity properties of synchronous machine systems,” arXiv preprint arXiv:2605.04796, 2026.arxiv.org/abs/2605.04796
- [10]L. Harnefors, M. Bongiorno, and S. Lundberg, “Passivity-based stability assessment of grid-connected vscs—an overview,” IEEE Journal of Emerging and Selected Topics in Power Electronics, vol. 4, no. 1, pp. 116–125, 2016.DOI
- [11]J. P. Koeln and A. G. Alleyne, “Stability of decentralized model predictive control of graph-based power flow systems via passivity,” Automatica, vol. 82, pp. 29–34, 2017.DOI
- [12]P. Nahata, R. Soloperto, M. Tucci, A. Martinelli, and G. Ferrari-Trecate, “A passivity-based approach to voltage stabilization in dc microgrids with zip loads,” Automatica, vol. 113, p. 108770, 2020.DOI
- [13]K. Dey and A. M. Kulkarni, “Analysis of the passivity characteristics of synchronous generators and converter-interfaced systems for grid interaction studies,” International Journal of Electrical Power & Energy Systems, vol. 129, p. 106818, 2021.DOI
- [14]K. Laib, J. Watson, Y. Ojo, and I. Lestas, “Decentralized stability conditions for dc microgrids: Beyond passivity approaches,” Automatica, vol. 145, p. 110705, 2022.arxiv.org/abs/2109.02708
- [15]P. Yang, F. Liu, Z. Wang, and C. Shen, “Distributed stability conditions for power systems with heterogeneous nonlinear bus dynamics,” IEEE Transactions on Power Systems, vol. 35, no. 3, pp. 2313–2324, 2020.arxiv.org/abs/1908.01927
- [16]M. Li, E. Liu, H. Geng, Y. Mao, X. Wang, X. Zhang, and J. Xu, “Distributed stability analysis of power system with grid-forming inverter-based power stations using differential passivity theory,” Electric Power Systems Research, vol. 260, p. 113298, 2026.
- [17]Z. Li, X. Ru, X. Peng, B. Tan, P. Gao, and F. Liu, “How passivity of bus dynamics influences power system stability: A sensitivity analysis,” in 2025 IEEE 9th Conference on Energy Internet and Energy System Integration (EI2). IEEE, 2025, pp. 1424–1429.DOI
- [18]X. Ru, R. Cu, F. Zu, X. Peng, and F. Liu, “Toward less conservative distributed stability analysis of power systems via matrix-valued differential passivity indices,” 2026. [Online]. Available: https://arxiv.org/abs/2605.04821
- [19]X. Ru, X. Peng, X. Chen, Z. Wang, P. Yang, and F. Liu, “Matrix-valued passivity indices: Foundations, properties, and stability implications,” arXiv preprint arXiv:2601.04796, 2026.arxiv.org/abs/2601.04796
- [20]P. Yang, X. Peng, X. Ru, H. Geng, and F. Liu, “Compositional and equilibrium-free conditions for power system stability—part i: Theory,” arXiv preprint arXiv:2506.11406, 2025.arxiv.org/abs/2506.11406
- [21]P. Yang, Y. Su, X. Peng, H. Geng, and F. Liu, “Compositional and equilibrium-free conditions for power system stability—part ii: Method and application,” arXiv preprint arXiv:2506.11411, 2025.
- [22]J. C. Willems and H. L. Trentelman, “On quadratic differential forms,” SIAM Journal on Control and Optimization, vol. 36, no. 5, pp. 1703–1749, 1998.
- [23]M. J. Tippett and J. Bao, “Control of plant-wide systems using dynamic supply rates,” Automatica, vol. 50, no. 1, pp. 44–52, 2014.DOI
- [24]A. Megretski and A. Rantzer, “System analysis via integral quadratic constraints,” IEEE Transactions on Automatic Control, vol. 42, no. 6, pp. 819–830, 1997.
- [25]P. Seiler, “Stability analysis with dissipation inequalities and integral quadratic constraints,” IEEE Transactions on Automatic Control, vol. 60, no. 6, pp. 1704–1709, 2015.DOI
- [26]S. Z. Khong, C. Chen, and A. Lanzon, “Feedback stability analysis via dissipativity with dynamic supply rates,” Automatica, vol. 172, p. 112000, 2025.
- [27]U. Topcu, A. Packard, and R. M. Murray, “Compositional stability analysis based on dual decomposition,” in Proceedings of the 48th IEEE Conference on Decision and Control, 2009, pp. 1175–1180.DOI
- [28]C. Meissen, L. Lessard, M. Arcak, and A. K. Packard, “Compositional performance certification of interconnected systems using ADMM,” Automatica, vol. 61, pp. 55–63, 2015.arxiv.org/abs/1410.2006
- [29]S. Boyd, N. Parikh, E. Chu, B. Peleato, and J. Eckstein, “Distributed optimization and statistical learning via the alternating direction method of multipliers,” Foundations and Trends in Machine Learning, vol. 3, no. 1, pp. 1–122, 2011.
- [30]A. Van der Schaft, L2-gain and passivity techniques in nonlinear control. Springer, 2000.
- [31]H. K. Khalil, Nonlinear systems. Prentice Hall, 2002.
- [32]X. He and F. Dörfler, “Passivity and decentralized stability conditions for grid-forming converters,” IEEE Transactions on Power Systems, vol. 39, no. 3, pp. 5447–5450, 2024.DOI
- [33]J. W. Simpson-Porco, F. Dörfler, and F. Bullo, “Voltage stabilization in microgrids via quadratic droop control,” IEEE Transactions on Automatic Control, vol. 62, no. 3, pp. 1239–1253, 2017.
- [34]P. A. Parrilo, “Structured semidefinite programs and semialgebraic geometry methods in robustness and optimization,” Ph.D. dissertation, California Institute of Technology, Pasadena, CA, USA, 2000.DOI
- [35]A. Papachristodoulou and S. Prajna, “A tutorial on sum of squares techniques for systems analysis,” in Proceedings of the 2005 American Control Conference. Portland, OR, USA: IEEE, 2005, pp. 2686–2700.DOI
- [36]R. D. Zimmerman, C. E. Murillo-Sánchez, and R. J. Thomas, “Matpower: Steady-state operations, planning, and analysis tools for power systems research and education,” IEEE Transactions on Power Systems, vol. 26, no. 1, pp. 12–19, 2011.