Abstract

This paper introduces a perspective approach for simulating a memristive sensor tailored for low power biological analyte detection. The necessity for such innovation stems from the increasing demand for efficient biosensing technologies that can operate with minimal poxer consumption. Within this study, a numerical dynamic memristive model serves as a basis platform for implementing enhanced nanosensing method characterized by low cost and high sensitivity. Numerous simulations were conducted to validate the suitability of the dynamic memristive model's behaviour for emulating a chemical sensing approach. The simulated data is collected for deploying an AI application to ensure an advanced predictable biosensing intake function. All in all, this work paves the way for developing compact numerical models of memristive biosensors, addressing the pressing need for portable lox poxer consumption biosensing solutions.

Introduction

Memristors as fourth passive circuit components, often show long state lifetime and ultra-fast switching by utilizing relatively small biases, increasing switching speed by up to six orders of magnitude due to their highly non-linear switching rate [1]. The rapid switching capability is among the reasons that the ongoing attempts are determined to integrate memristors in different fields specifically the biosensing domain [2]. Despite the advancements in the biosensing field, traditional technologies continue to encounter energy and time consumption challenges that restrict their effective operation and utility in various applications [3].

In our previous work, we studied the dynamics of a simulated memristive biosensing model [4]. However, in this study, we focus on simulating memristive bio-adsorption, emulating a chemical sensor for highly sensitive, fast-responding, and cost-effective nano-detection. The simulation data is extracted for implementing an AI-based predictable adsorption model ensuring the creation of an innovative direction in the memristive biosensing field.

The body of the paper is organized as follows. Section II reviews the state of the art of memristive technologies and the important milestones. Section III reports the state of the art of the memristive biosensing concept. Section IV emphasizes the simulation prospect of chemical fluidic sensor. The results of the approach investigation are shown and discussed in Section V. Finally, section VI concludes the study and outlines our future perspectives.

State of the Art

Memristor

Since their fabrication within HP labs in 2008 [5], memristors have gained the interest of researchers as they overtake classical von Newman architectures in terms of rapidity [6], power [7], and density [8]. Indeed, while conventional biosensors typically exhibit significantly higher power consumption [9, 10], memristive devices operate with substantially reduced power requirements. [11] As such, various applications have been developed, citing memristive artificial neural networking (ANN) [12], memristive biosensing [13] and analogue computing, particularly in the context of neuromorphic computing aimed at hardware security [14]. Figure 1 presents the progression of memristive applications within the context of the annual number of publications.

Number of publications of memristive applications per year

Figure 1. Memristive applications: number of publications per year (dataset is extracted From Scopus), (a) Number of publications of memristive biosensing.

Memristive Bio-sensing

The memristive biosensor is a nonvolatile memory nano-scaled module capable of sensing bio-molecules once functionalized [15]. One of the most common structures is made of memristive bio-functionalized Schottky barrier silicon nanowires where the resistance change involves the modulation of Schottky barriers and surface charge difference due to bio-receptor interactions [16]. In this case, the sensing mechanism detects changes in surface potential or charge distribution on silicon nanowires. Generally, the sensing process shows a voltage gap varying relatively to both functionalization and detection processes [17]. This kind is often characterized by a bipolar memristive behaviour corresponding to a couple of back-to-back Schottky diodes in contrarily functioning [18]. Figure 2 describes the architecture of a conventional Schottky barrier silicon nanowires-based memristive biosensor [15].

Schottky barrier memristive silicon nano-wire

Figure 2. Schottky barrier memristive silicon nano-wire [15].

Another prevalent memristive biosensing systems based on metal oxide memristors exist. They operate with the variation in resistive states during both bio-receptor fixation and bio-analyte intake [19]. Indeed, the variation of the metal oxide’s resistance provokes a change in the memristor’s resistive state. Furthermore, the interactions of the memristor with the fixed bio-receptors and bio-analytes, result in the modification of the resistive states of the memristor, hence, the memristive bio-sensor [20]. Typically, this memristive biosensor features a vertical structure comprising a metal oxide layer positioned between two metal electrodes, with the possible inclusion of a conductive filament [19]. Figure 3 describes the architecture of a metal oxide-based memristive biosensor and the effect of the increase of the antigen intake [PSA] [19].

Metal oxide memristive biosensor

Figure 3. Metal oxide memristive biosensor [19]. (a-b): model structure.(c-d):: resistive state variation VS input bias.

Digging deeper into the history, in 2011 David sacchetto et al. introduced memristive properties for biosensing through functionalized Schottky-barrier Silicon nanowires [13]. The

study proved that the voltage-current hysteresis characterization appears after the functionalization and shrinks with the bio-molecule intake. Moreover, in 2012, Sandro Carrara and his team emphasized a new detection for dried samples using memristive silicon contacts that were fabricated with a lithography process [15]. Further theoretical analysis showed detection sensitivity is equal to 37±137 \pm1 mV/fM and the limit of detection is around 3,4±1,83,4 \pm1,8 fM. In 2014, the team focused on observing the humidity effect on the hysteretic voltage gap of bio-modified silicon wires [16]. In 2016, Alessandro Vallero et al. proposed the first memristive biosensing platform integrated with a microfluidic structure [21]. This study reports a fast label-free data collection with high-reliability features. In the same year, a study conducted by Ioulia Tzouvadaki claimed the elaboration of an ultra-sensitive apta-sensor for Prostate-Specific antigen (PSA) monitoring with the best limit of detection (2323 aM) within apta-sensing field [22]. In 2017, a memristive crossbar-based gas sensor was introduced by Adedotun Adeyemo et al [20]. In 2018, Ioulia Tzouvadaki et al. proposed a single-chip structure for multiple bio-sensing frameworks with fast, simultaneous, and automatic output data [23]. Furthermore, in 2019, Ioulia Tzouvadaki presented a multi-panel for single or multiple markers’ sensing from one sample in-closing one or numerous molecules with a remarkable limit of detection that is around 1.61.6 fM [24]. Equally important, in 2020, Ioulia Tzouvadaki worked on a metal oxide memristive device for PSA concentration’s bio-detection with 0.60.6 ng/ml as a limit of detection [19]. Last but not least, in 2023, Zrinski et al. conducted a study about a memristive crossbar array for liquid D-glucose hydroxide sensing with a detection range that varies between 1010 mM and 8080 mM [25]. The table ”I” below represents a critical summary of the limit of detection of some memristive sensing technologies.

StudyLimit of DetectionYearRef.
Memristive Biosensors: A New Detection Method By Using Nanofabricated Memristors3.4 ± 1.8 fM2012[15]
Memristive Biosensors Under Varying Humidity Conditions0.6 to 1.2 fM2014[16]
Label-Free Ultrasensitive Memristive Aptasensor23 aM2016[22]
Fabrication And Characterization Of Simple Structure Fluidic-Based Memristor For Immunosensing Of NS1 Protein Applications52nM2020[26]
Anodic HfO2 Crossbar Arrays For Hydroxide-Based Memristive Sensing In Liquids: Original Scientific Paper10mM to 80mM2023[25]

Table I. SAMPLES OF MEMRISTIVE BIO-SENSING’S LIMIT OF DETECTION

Simulation of AI-based Memristive Biosensor

Modelling of Memristor Device

Fig. 4 illustrates a 2D and 3D dynamic metal oxide memristive models that refer to the study of Kim Sungho et al. [27]. This structure is employed for the investigation of our study goal.

Structure of the simulated metal oxide memristive device

Figure 4. Structure of the simulated metal oxide memristive device.

The model includes the integration of highly resistive Ta2O5Ta_2O_5 and less resistive TaOxTaO_x layers positioned between two palladium electrodes, namely the word line (WL) responsible for memory signal transmission and the bit line (BL) serving as the ground reference [28], [29], [30]. This device adopts a unipolar RRAM switching behaviour of the Pd/Ta2O5/TaOx/PdPd/Ta_2O_5/TaO_x/Pd device which is widely acknowledged to involve the formation and rupture of the metal CF where it forms between the upper and lower Pd electrodes. In the absence of the CF, the RRAM remains in a high-resistive state (HRS), transitioning to a low-resistive state (LRS) upon CF formation. The memristor model is characterized by numerous variables and physical fundamentals which are summed in (1), (2) and (3) respectively presenting, the oxygen vacancy transport, the current continuity and the joule heating equations. For the oxygen vacancy transport, the following mass balance equation (1) is introduced and it implicates transport mechanisms such as diffusion and convection.

∂ci∂t+∇⋅j+u⋅∇ci=Ri(1)\frac{\partial c_i}{\partial t}+\nabla\cdot\mathbf{j}+u\cdot\nabla c_i=R_i \tag*{(1)}

In this equation, cic_i presents the species concentration (mol/m3mol/m^3), RiR_i is the reaction rate (mol/(m3⋅s)mol/(m^3\cdot s)), while uu is the mass averaged velocity vector (m/sm/s), and jj is the mass diffusive flux vector (mol/(m2⋅s)mol/(m^2\cdot s)). Moreover, the electric continuity is described with the equation (2).

∇σ∇ψ=0(2)\nabla\sigma\nabla\psi=0 \tag*{(2)}

With σ\sigma is the electric conductivity (S/m), jj is the current density (A/m2^2), and ψ\psi is the electric potential (V). For the resistive heating, an elliptic partial differential equation for the temperature is defined below:

ρCp∂T∂t+∇q=Q(3)\rho C_p\frac{\partial T}{\partial t}+\nabla q=Q \tag*{(3)}

qq refers to the conductive heat flux (W/m2^2), q=−kth∇Tq=-k_{th}\nabla T, kthk_{th} is the thermal conductivity (W/(m.k)), ρ\rho is the density (kg/m3kg/m^3) while CpC_p is the specific heat capacity at constant pressure (J/(kg·K)) and Q is the heat source (W/m3^3). These equations exhibit time dependency, with an initial temperature set at 300K. Furthermore, both of electrical conductivity and thermal conductivity are defined respectively with equations (4) and (5) as it is indicated below. Certainly, the parameters of those equations are inferred and subjected to certain assumptions based on Youto Nakamura’s research [31].

σ=σ0exp⁡(−EacKT)(4)\sigma=\sigma_0\exp\left(-\frac{E_{ac}}{KT}\right) \tag*{(4)}

With σ0\sigma_0 is the pre-exponential factor of the electrical conductivity (S/m), EacE_{ac} is the activation energy for conduction (eV), K is Boltzmann constant (j/K), and T refers to the temperature (K).

Kth=Kth0(1+λ(T−T0))(5)K_{th}=K_{th0}(1+\lambda(T-T_0)) \tag*{(5)}

Kth0K_{th0} is the initial thermal conductivity coefficient (W/m k). In our case, The initial temperature value, T0=300T_0=300K and λ=0.1\lambda=0.1.

Modelling of Memristive Biosensor Technology

Lately, numerous experimental and theoretical investigations have emerged, aimed at elaborating an enhanced biosensor response [32]. Typically, the theoretical biosensing mechanisms are based on mathematical isotherms and kinetics. The most common adsorption isotherms are Langmuir and Freundlich kinetics [33]. Langmuir’s model serves as a simplified representation, offering a basic approximation of monolayer adsorption with no interaction between the adsorbed species. Besides, it describes a reversible mechanism onto a homogeneous surface with a finite number of identical sites [34]. Contrarily, the Freundlich approximation allows the adsorption of multi-layers and the interaction between the adsorbed species [35]. It describes heterogeneous surfaces and non-ideal adsorption behaviour [36]. Also, it implies that adsorption increases proportionally with the concentration, suggesting a non-uniform distribution of active sites [37]. In this work, a simple Langmuir approximation is employed to describe the bulk species fixation on the memristive device’s top palladium electrode according to equation (6).

ϑ=(KadsCi)(1+(KadsCi))(6)\vartheta= \frac{(K_{\mathrm{ads}} C_i)}{(1 + (K_{\mathrm{ads}} C_i))} \tag*{(6)}

In this case, ϑ\vartheta describes the surface coverage conductivity (dimensionless), CiC_i is the concentration of the analyte in the solution (mol/m3\mathrm{mol}/\mathrm{m}^{3}), and KadsK_{\mathrm{ads}} is the Langmuir constant (1/(M.s)). The following equation expresses the chemical reaction representing the adsorption of the analyte onto a surface ”(7)”:

Ab⇌Kads′As(7)\mathrm{Ab} \xrightleftharpoons[K'_{\mathrm{ads}}]{} \mathrm{As} \tag*{(7)}

In this study, Ab presents the concentration Ci (mol/m3\mathrm{mol}/\mathrm{m}^{3}), As is the concentration of adsorbed species (mol/m2\mathrm{mol}/\mathrm{m}^{2}), and KadsK_{\mathrm{ads}} is the Langmuir constant (1/(M.s)). Figure 5 reports further details of the fixation reaction. The memristive device and the adsorption kinetics simulation are elaborated within COMSOL Multiphysics and the preliminary results are shown and discussed in the coming section.

Langmuir adsorption assumption for analyte fixation on the top electrode of the memristive device

Figure 5. Langmuir adsorption assumption for analyte fixation on the top electrode of the memristive device.

Results and Discussion

Simulation of Dynamic Memristive Device

The inputs and outputs of the memristor

Figure 6. The inputs and outputs of the memristor. (a): The applied voltage bias. (b): The output current variation.

The stimulation of the dynamic memristor with a sinusoidal pulse bias (figure 6 (a) ) results in distinguished preliminary outcomes. Indeed, applying a pulse train with 1.2 V as amplitude and 1000 ns as period we obtained the following figure 6 (b) that illustrates the variation of the current during

The memristor’s output current variation as function of different input voltage values

Figure 7. The memristor’s output current variation as function of different input voltage values.

a simulation time equal to 2000 ns. The observed I-V curves figure 7 display the reset and set mechanisms for bias ranging between 1V and 1.8V. While the reset transition starts at the negative side of the curve, The set begins around 1V after simulating the electro-formation of the CF as a set. The pinched hysteresis pattern intersects the origin refers to the presence of memory effect. The two hysteresis lobes are attributed to the migration of oxygen vacancies serving as charge carriers rather than phase transitions. The concentration of oxygen vacancies is modelled by solving equation (1) close to the memristor’s top palladium electrode and it is crucial for the resistive switching. Specifically, the increase of the V0 concentration launches the low resistance state (LRS) imitating the formation of the CF, however, diminishing the V0 concentration leads to the decrease of the conductivity, thus, the high resistance state (HRS).

Simulation of Memristive Biosensor Device

The results depicted in figure 8 (blue line) illustrates the variation of the adsorbed species (CadsC_{\mathrm{ads}}) within the memristive top electrode. The increase of the (CadsC_{\mathrm{ads}}) during the simulation means the increase of the analyte intake by the sensor. The curve exhibits two distinct phases. The initial transition phase is characterised by (CadsC_{\mathrm{ads}}) ranging from 0 mol/m3^{3} to 3.10−7^{-7}mol/m3^{3}. The saturation phase, which initiates before 500 ns and reaches a maximum (CadsC_{\mathrm{ads}}) of approximately 3.10−7^{-7}mol/m3^{3} indicates that the sensing platform is performing at a fast pace. This rapid response time observed is attributed to the swift resistive switching characteristic of the memristive technology. Furthermore, The limit of detection of this sensor is around 0.308 Umol/m3^{3}.

Artificial Intelligence Application for Adsorption Model Prediction

To facilitate the AI-based cleaning process, the simulated data is directly extracted from COMSOL Multiphysics utilizing the plot exporting function. A further step is deploying a machine learning (ML) model for a smart adsorption model that predicts the concentration of adsorbed species from a given time slot or array. A correlation between the raw dataset and the ML Langmuir isotherm led to a fitting fundamental parameters of the smart adsorption model according to equation (6) and Nonlinear Least Squares (NLLS) optimization. In fact, this method concludes the following values of fitting parameters where the maximum Langmuir adsorption model’s capacity qmax⁡q_{\max} is around 3.043⋅10−7 mol/m33.043 \cdot10^{-7}\ \mathrm{mol/m^3}. Furthermore, the Langmuir and time constants are respectively circling 0.0153 m3/mol0.0153\ \mathrm{m^3/mol} and 0.657 ns0.657\ \mathrm{ns}. Figure 8 (red stars) illustrates the extracted dataset from the simulation and the AI-predicted data array. The two curves clearly show a low root mean squared error about 6.148⋅10−9 mol36.148 \cdot10^{-9}\ \mathrm{mol^3}, a coefficient of determination (R squared) framing 0.9615 and a high correlation between the two methods. This ML model is a perspective paradigm of a smart prototype of Langmuir-based memristive biosensing intake modelling and data fitting.

Data correlation of the concentration of adsorbed species

Figure 8. Data correlation of the concentration of adsorbed species.

Conclusion and Perspectives

In summary, This paper presents an innovative approach to simulating memristive sensors designed for low-power detection of biological analytes. Through the utilization of simulated memristive structures as foundational platforms, this study demonstrates the potential for implementing advanced sensing paradigms. Memristive devices emerge as promising solutions, offering a highly sensitive and cost-effective nano-sensing method. Extensive simulations validated the effectiveness of dynamic memristive models in replicating the behaviour of memristive chemical sensors. The incorporation of the sensing memristive pattern ensures the reliability of data collection and processing to facilitate AI applications.

Acknowledgment

This work is achieved thanks to the scholar funds of the University of Monastir, the faculty of Sciences of Monastir and the Laboratory of Micro-electronics of Monastir (LR99ES30).

References

  1. [1]T. Prodromakis and C. Toumazou. A review on memristive devices and applications. In 2010 17th IEEE International Conference on Electronics, Circuits and Systems, pages 934–937, 2010.DOI
  2. [2]Alexander Vahl, Ju¨rgen Carstensen, Søren Kaps, Lupan Oleg, Thomas Strunskus, Rainer Adelung, and Franz Faupel. Concept and modelling of memsensors as two terminal devices with enhanced capabilities in neuromorphic engineering. Scientific Reports, 9:4361, 03 2019.DOI
  3. [3]Madhukar Varshney and Kumar Mallikarjunan. Challenges in biosensor development: Detection limit, detection time, and specificity. Resource: Engineering and Technology for Sustainable World, 16(7):18–21, 10 2009.DOI
  4. [4]Manel Bouzouita, Fakhreddine Zayer, Ioulia Tzouvadaki, Sandro Carrara, and Hamdi Belgacem. Exploring memristive biosensing dynamics: A comsol multiphysics approach, 2024.arxiv.org/abs/2406.01854
  5. [5]Dmitri B Strukov, Gregory S Snider, Duncan R Stewart, and R Stanley Williams. The missing memristor. nature, 453(7191):80–83, 2008.DOI
  6. [6]Fakhreddine Zayer, Wael Dghais, and Hamdi Belgacem. Improved tio2 team model using a new window function. In 2018 30th International Conference on Microelectronics (ICM), pages 236–239, 2018.DOI
  7. [7]Khitem Lahbacha, Fakhreddine Zayer, Hamdi Belgacem, Wael Dghais, and Antonio Maffucci. Thermal and signal integrity improvement in a 3d rram crossbar with carbon nanotube interconnects. In 2023 IEEE Nanotechnology Materials and Devices Conference (NMDC), pages 648–653. IEEE, 2023.DOI
  8. [8]F Zayer, W Dghais, M Benabdeladhim, and B Hamdi. Low power, ultrafast synaptic plasticity in 1r-ferroelectric tunnel memristive structure for spiking neural networks. AEU-International Journal of Electronics and Communications, 100:56–65, 2019.DOI
  9. [9]Kiichi Niitsu, Atsuki Kobayashi, Yuya Nishio, Kenya Hayashi, Kei Ikeda, Takashi Ando, Yudai Ogawa, Hiroyuki Kai, Matsuhiko Nishizawa, and Kazuo Nakazato. A self-powered supply-sensing biosensor platform using bio fuel cell and low-voltage, low-cost supply-controlled ring oscillator with inductive-coupling transmitter for healthcare iot. IEEE Transactions on Circuits and Systems I: Regular Papers, 65(9):2784–2796, 2018.DOI
  10. [10]Mo Zhang, Mohammad R Haider, Mohammad A Huque, Mohammad A Adeeb, Shaela Rahman, and Syed K Islam. A low power sensor signal processing circuit for implantable biosensor applications. Smart Materials and Structures, 16(2):525, 2007.
  11. [11]Fakhreddine Zayer, Wael Dghais, and Hamdi Belgacem. Modeling framework and comparison of memristive devices and associated stdp learning windows for neuromorphic applications. Journal of Physics D: Applied Physics, 52(39):393002, 2019.DOI
  12. [12]Alexandre Touré, Andrea Corna, Richard George, Ali Khiat, Federico Rocchi, Marco Reato, Marta Maschietto, Christian Mayr, Giacomo Indiveri, Stefano Vassanelli, et al. Memristive synapses connect brain and silicon spiking neurons. Scientific reports, 10(1):2590, 2020.
  13. [13]Davide Sacchetto, Marie-Agnè`s Doucey, Giovanni De Micheli, Yusuf Leblebici, and Sandro Carrara. New insight on bio-sensing by nano-fabricated memristors. BioNanoScience, 1:1–3, 2011.DOI
  14. [14]Hala Ajmi, Fakhreddine Zayer, Amira Hadj Fredj, Hamdi Belgacem, Baker Mohammad, Naoufel Werghi, and Jorge Dias. Efficient and lightweight in-memory computing architecture for hardware security. Journal of Parallel and Distributed Computing, 190:104898, 2024.
  15. [15]Sandro Carrara, Davide Sacchetto, Marie-Agne`s Doucey, Camilla Baj-Rossi, Giovanni De Micheli, and Yusuf Leblebici. Memristive-biosensors: A new detection method by using nanofabricated memristors. Sensors and Actuators B: Chemical, 171:449–457, 2012.DOI
  16. [16]Francesca Puppo, Akshat Dave, Marie-Agne`s Doucey, Davide Sacchetto, Camilla Baj-Rossi, Yusuf Leblebici, Giovanni De Micheli, and Sandro Carrara. Memristive biosensors under varying humidity conditions. IEEE Transactions on NanoBioscience, 13(1):19–30, 2014.DOI
  17. [17]Hirendra Das and Pranayee Datta. A brief review on memristive biosensors.
  18. [18]Davide Sacchetto, M Haykel Ben-Jamaa, Sandro Carrara, Giovanni De Micheli, and Yusuf Leblebici. Memristive devices fabricated with silicon nanowire schottky barrier transistors. In Proceedings of 2010 IEEE International Symposium on Circuits and Systems, pages 9–12. IEEE, 2010.DOI
  19. [19]Ioulia Tzouvadaki, Spyros Stathopoulos, Tom Abbey, Loukas Michalas, and Themis Prodromakis. Monitoring psa levels as chemical state- variables in metal-oxide memristors. Scientific Reports, 10(1):15281, 2020.
  20. [20]Adedotun Adeyemo, Abusaleh Jabir, Jimson Mathew, Eugenio Martinelli, Corrado Di Natale, and Marco Ottavi. Reliable gas sensing with memristive array. In 2017 IEEE 23rd International Symposium on On-Line Testing and Robust System Design (IOLTS), pages 244–246. IEEE, 2017.DOI
  21. [21]Alessandro Vallero, Ioulia Tzouvadaki, Francesca Puppo, Marie-Agnè`s Doucey, Jean-Franç̧ois Delaloye, Giovanni De Micheli, and Sandro Carrara. Memristive biosensors integration with microfluidic platform. IEEE Transactions on Circuits and Systems I: Regular Papers, 63(12):2120–2127, 2016.DOI
  22. [22]Ioulia Tzouvadaki, Pawan Jolly, Xiaoling Lu, Sven Ingebrandt, Giovanni De Micheli, Pedro Estrela, and Sandro Carrara. Label-free ultrasensitive memristive aptasensor. Nano letters, 16(7):4472–4476, 2016.DOI
  23. [23]Ioulia Tzouvadaki, Abuduwaili Tuoheti, Giovanni De Micheli, Danilo Demarchi, and Sandro Carrara. Portable memristive biosensing system as effective point-of-care device for cancer diagnostics. In 2018 IEEE International Symposium on Circuits and Systems (ISCAS), pages 1–5. IEEE, 2018.
  24. [24]Ioulia Tzouvadaki, Abuduwaili Tuoheti, Se’verine Lorrain, Manfredo Quadroni, Marie-Agnè`s Doucey, Giovanni De Micheli, Danilo Demarchi, and Sandro Carrara. Multi-panel, on-single-chip memristive biosensing. IEEE Sensors Journal, 19(14):5769–5774, 2019.DOI
  25. [25]Ivana Zrinski, Dominik Knapic, Achim Walter Hassel, and Andrei Ionut Mardare. Anodic hfo2 crossbar arrays for hydroxide-based memristive sensing in liquids. Journal of Electrochemical Science and Engineering, 13(5):805–815, 2023.
  26. [26]Nor Shahanim Mohamad Hadis, Asrulnizam Abd Manaf, Mohamad Faizal Abd Rahman, Siti Hawa Ngalim, Thean Hock Tang, Marimuthu Citartan, Aziah Ismail, and Sukreen Hana Herman. Fabrication and characterization of simple structure fluidic-based memristor for immunosensing of ns1 protein application. Biosensors, 10(10):143, 2020.
  27. [27]Sungho Kim, ShinH̀yun Choi, and Wei Lu. Comprehensive physical model of dynamic resistive switching in an oxide memristor. ACS nano, 8(3):2369–2376, 2014.
  28. [28]FakhrEddine Zayer, Wael Dghais, and Hamdi Belgacem. Tio2 memristor model-based chaotic oscillator. In 2017 24th IEEE International Conference on Electronics, Circuits and Systems (ICECS), pages 54–57, 2017.DOI
  29. [29]Zayer Fakhreddine, Khitem Lahbacha, Alexander Melnikov, Hamdi Belgacem, Massimiliano de Magistris, Wael Dghais, and Antonio Maffucci. Signal and thermal integrity analysis of 3-d stacked resistive random access memories. IEEE Transactions on Electron Devices, 68(1):88–94, 2020.
  30. [30]F Zayer, K Lahbacha, W Dghais, H Belgacem, Massimiliano de Magistris, Alexander V Melnikov, and Antonio Maffucci. Electrothermal analysis of 3d memristive 1d-Irram crossbar with carbon nanotube electrodes. In 2019 IEEE International Conference on Design & Test of Integrated Micro & Nano-Systems (DTS), pages 1–6. IEEE, 2019.
  31. [31]Yuto Nakamura and Yusuke Nishi. Simulation of analog resistance change characteristics in pt/tao2/pt cells. Japanese Journal of Applied Physics, 61(SM):SM1012, 2022.
  32. [32]Hasnia Hajji, Lioua Kolsi, Walid Hassen, Abdullah AAA Al-Rashed, Mohamed Naceur Borjini, and Mohamed Ahmed Aichouni. Finite element simulation of antigen-antibody transport and adsorption in a microfluidic chip. Physica E: Low-dimensional Systems and Nanostructures, 104:177–186, 2018.
  33. [33]Linné`a Petersson. Modeling transport phenomena with comsol multi-physics. 2020.
  34. [34]D Brynn Hibbert, J Justin Gooding, and Paul Erokhin. Kinetics of irreversible adsorption with diffusion: Application to biomolecule immobilization. Langmuir, 18(5):1770–1776, 2002.
  35. [35]AUOA Proctor and JF Toro-Vazquez. The freundlich isotherm in studying adsorption in oil processing. Journal of the American Oil Chemists’ Society, 73:1627–1633, 1996.
  36. [36]J Appel. Freundlich’s adsorption isotherm. Surface Science, 39(1):237–244, 1973.DOI
  37. [37]Michael Vigdorowitsch, Alexander Pchelintsev, Liudmila Tsygankova, and Elena Tanygina. Freundlich isotherm: An adsorption model complete framework. Applied Sciences, 11(17):8078, 2021.

Paper details

vlnc:W_9tt2a54c
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents