WorksComputer Science
Directed brain-body graphs across timescales
Abstract
Simultaneous brain and body recordings combine signals sampled at very different rates with processes that act on timescales from milliseconds to minutes. Placing all signals on one time grid can distort the directed relationships estimated from them. Unmeasured common influences can also make one signal appear to drive another. We introduce rate-matched Granger causality (RMGC), which estimates directed predictive relationships without a common sampling grid. Each relationship receives a robustness value, the strength of the weakest common influence found within a specified class that can reproduce it. A neural extension tests for nonlinear relationships. In a controlled benchmark, RMGC recovered more true relationships than four established methods and an autoregressive model on a common grid (92% at a false-positive rate of 5%). Given the same signal features, the common-grid model matched this recovery but had more than twice the false-positive rate, and it reversed the relationship from respiration to heart rate. The robustness value never overstated the strength of the driver behind a spurious relationship, even for drivers outside the searched class. It separated true from spurious relationships better than predictive strength did. In overnight sleep recordings and two awake datasets, many brain–heart relationships could be reproduced by common drivers no stronger than measured respiration. Robustness values only partly identified those that appeared when respiration was omitted, particularly during wakefulness. Surrogate analyses showed elevated background rates in one awake dataset. The approach applies to other signals recorded at different rates or as events, provided that influences act with a delay.
Introduction
The brain continuously receives signals from the body while contributing to the regulation of cardiac, respiratory and autonomic activity. The relevance of these exchanges extends to perception and behaviour (reviewed in Azzalini et al., [4]). In humans, neural responses to heartbeats predict the detection of faint visual stimuli (Park et al., [49]), while nasal respiration is associated with the timing of limbic oscillations and performance in memory and emotion-related tasks (Zelano et al., [64]). Such findings motivate the study of brain activity within its physiological context. Understanding brain–body coordination requires examining how neural and peripheral processes vary together, how their relationships are organized in time, and how those relationships can be interpreted from simultaneous recordings.
Network physiology (Ivanov, [36]) provides a framework for investigating this coordination across interacting physiological systems. It asks how the organization of relationships among systems contributes to physiological function and changes with the state of the organism. Studies of sleep have identified distinct patterns of connectivity among brain activity, cardiac and respiratory signals, and other physiological processes, linking changes in network structure to transitions
Simulator, benchmark and implementation details
between sleep stages [11, 10]. These observations make the relationships between systems an object of investigation in their own right. For brain–body research, this perspective motivates joint analysis of multiple signals and careful consideration of what an inferred connection between them represents.
One useful description concerns the direction of predictive relationships: whether the past of one signal provides information about another beyond that already available from its own history and the other observed signals. Granger causality formalizes this question [33], and related analyses of predictive information have been used to characterize brain–heart networks during sleep [25]. A directed graph can therefore summarize how information in recorded signals contributes to predicting their subsequent activity. Its interpretation depends, however, on the temporal resolution of the observations and the variables included in the analysis. Predictive direction alone does not establish a direct physiological pathway [9, 56] or identify the effect of an intervention [24].
Physiological recordings pose particular challenges because differences in sampling rates coexist with differences in the timescales of the underlying processes. Signals recorded using electroencephalography (EEG) are commonly sampled hundreds of times per second, whereas other sensors provide much slower measurements, and heartbeats form a sequence of events. A rapidly sampled signal can also carry slowly varying information: relationships with peripheral or haemodynamic signals may involve changes in neural power rather than the instantaneous electrical waveform. Representing all measurements on a common grid can obscure these distinctions. Coarse aggregation may lose fast temporal relationships, while a fine grid requires many past samples to represent slower dependencies. When one step of an indirect path from A through B to C is shorter than a bin, A can appear to act on C directly. On a fine grid, a slow signal must be filled in between its samples, either by holding the last value or by interpolation. Interpolation uses the next sample, so the filled-in values carry information from the future. Measurement noise in such signals can create spurious directed relationships and suppress true ones (Nalatore et al., 2007). Filtering leaves Granger causality unchanged in theory, but in practice it often changes the inferred relationships, because filtered signals need many more past samples to be modelled [5]. More generally, the relation between sampling intervals and interaction delays can change which directed dependencies are detectable [8]. Joint analysis therefore requires both an appropriate temporal representation and signal features that preserve the information relevant to interactions across timescales.
A further difficulty arises because physiological signals can share influences that are absent from the model. Respiration illustrates why this matters: it is related to both cardiac variability and neural activity [64], and omitting it can change the inferred directionality of cardiovascular relationships [51]. A common influence reaching two signals at different delays can make one predict the other even without a direct interaction between them [33]. Volume conduction, the spread of electrical activity from one source through the head to many scalp electrodes, leads Granger-causal measures to report spurious connectivity between EEG channels [35]. The same study showed that time-reversed data, used as surrogates, suppresses this effect while preserving time-lagged interactions. Recording likely common influences helps, but any set of measurements provides an incomplete view of physiological regulation. An observed relationship consequently raises a second question alongside its predictive strength: how susceptible is it to an unmeasured common influence capable of producing similar evidence?
Existing methods provide complementary approaches to these problems. Mixed-frequency Granger tests use observations collected at different rates [30], and multiscale formulations quantify predictive interactions at different temporal resolutions [26]. Structural vector autoregressions have been identified from subsampled and mixed-frequency series [57], and causal graphs have been learned from time series sampled at different rates ([2, 65]). Continuous-time models accommodate measurements taken at irregular intervals ([21]). Neural approaches extend the range of nonlinear relationships that can be represented ([58]). Recent neural methods combine several ranges of lags or time windows ([27, 52]) or treat irregular sampling as missing entries on a regular grid ([16]). All of these neural methods model the signals on a single sampling grid.
Causal-discovery methods for time series address uncertainty arising from latent confounders ([28]). Sensitivity analysis offers a further perspective by quantifying the influence an omitted variable would need to have to alter a regression-based conclusion, with measured variables providing interpretable benchmarks ([18]). For physiological network analysis, an important practical challenge is to combine an appropriate temporal representation of each signal with an explicit assessment of how unobserved common drivers could account for individual directed relationships. The broadest robustness benchmark of time-series causal discovery tests 33 violations of model assumptions ([55]). It deliberately leaves out the case in which coarse measurement resolution makes a lagged effect appear as a bidirectional relationship. We know of no method that combines prediction at each signal’s own rate, relationships across timescales and a per-relationship measure of robustness to unmeasured common drivers, nor of a benchmark that tests these properties together.
Here we introduce rate-matched Granger causality (RMGC), which predicts signals at temporal resolutions matched to their sampling rates while representing other signals through windows of their own past observations. This avoids imposing a single common sampling grid. Fast signals contribute information about both their mean and their power when predicting slower targets. The neural-network extension of rate-matched Granger causality (RMGC-NN) provides an additional test for nonlinear predictive relationships. Each detected relationship is accompanied by a robustness value, obtained by searching for a simulated common driver that can reproduce its predictive strength after its fitted contribution has been removed. The value describes the weakest explanation found within the tested driver class and can be compared with a measured physiological variable such as respiration. It provides a measure of sensitivity whose interpretation remains conditional on the drivers considered.
We evaluate this framework in simulations and physiological recordings acquired during sleep and wakefulness. A controlled benchmark tests interactions across timescales, different sampling rates, heartbeat events, hidden common drivers, volume conduction and a nonlinear relationship. Comparisons with established methods, including analyses with comparable signal features, and component ablations examine the contributions of temporal representation and model design. In overnight sleep recordings and two awake datasets, we assess how inferred relationships change when respiration is omitted and use placebo and surrogate analyses to evaluate the specificity of these changes and background detection rates. Together, these evaluations examine when RMGC provides a useful description of directed brain–body relationships and how sensitivity to shared influences should inform the interpretation of physiological networks.
Methods
Signals, edges and tests
We observe signals. Signal arrives as samples at its own rate, or as event times. Physiological events are heartbeats (the R-peaks of the electrocardiogram). In experiments there is also a stimulus, for example the onset times of auditory beats: it is an input that can drive other signals but is never predicted itself.
Nodes. The nodes of the graph are the signals given to the method; the method does not discover them. Each node is one time series in one of three forms: a sampled signal (an EEG derivation or a regional average of electrodes, breathing, skin conductance), an event stream (heartbeats, entered as the rate of each completed beat, , at the time of the beat), or the stimulus (beat onsets), which can only be a source. A node may be a sensor channel as recorded, or a signal derived before the analysis from one or more channels: a regional average of EEG electrodes, the heart rate from the R-peaks of the electrocardiogram, the amplitude of a muscle signal. Three rules apply in every data set. Nodes are defined before the analysis and kept the same across conditions and recordings. No node may be a linear combination of others, which would make the tests ill-posed. And deriving a node must not shift its timing relative to the others: zero-phase filters whose effect is shorter than the time resolution at which the node is analysed are allowed (as for R-peak detection and muscle amplitude), whereas filters with delays, interpolation and resampling are not used. Unmeasured influences, such as the hidden drivers of the benchmark, are not nodes. Table 1 lists the nodes of each data set.
| Data set | Node | How it is obtained |
| Benchmark | STIM | stimulus beat onsets (2 Hz; 1.2 Hz in one scenario); source only |
| EEG1, EEG2 | simulated EEG-like sensors, 250 Hz | |
| RESP, fNIRS, SC | simulated breathing (25 Hz), fNIRS-like signal (8 Hz) and skin conductance (4 Hz) sensors | |
| HR | simulated heartbeats, as the rate of each completed beat | |
| Overnight sleep (CAP Sleep Database) | EEG1, EEG2 | two derivations as recorded, one central and one occipital or parietal where available; averaged to about 128 Hz |
| RESP | thoracic belt, or nasal airflow for n8; averaged to about 25 Hz | |
| HR | R-peaks of the electrocardiogram | |
| SpO₂ | oxygen saturation as recorded (n1 only) | |
| Awake video viewing (BBBD) | EEG LF, EEG RF, EEG LP, EEG RP | averages of F3, F5, F7, FC3 and FC5; F4, F6, F8, FC4 and FC6; P3, P5, P7, CP3 and CP5; P4, P6, P8, CP4 and CP6, after average reference; 128 Hz |
| RESP | chest belt; averaged to 25.6 Hz | |
| HR | hand-corrected R-peaks of the electrocardiogram | |
| PUPIL | pupil size from eye tracking; averaged to 25.6 Hz | |
| EOG | first principal component of the six EOG channels; 128 Hz | |
| Awake tasks (MultiPhysio-HRC) | EEG LF, EEG RF, EEG LP, EEG RP | averages of AF7 and F3; AF8 and F4; P3, PO7 and O1; P4, O2 and PO8, after average reference over the 12 dry electrodes (Fp1 and Fp2 left out: they carry eye movements, and with all 12 electrodes the four averages would sum to zero); about 128 Hz |
| RESP, EDA | chest band and skin conductance; averaged to about 25 Hz | |
| HR | R-peaks of the electrocardiogram | |
| EMG | trapezius electromyogram (EMG) amplitude: causal high-pass filter at 20 Hz, rectified, averaged to about 25 Hz |
Table 1. Nodes of each data set and how they are obtained.
A directed edge is declared when the past of improves the least-squares prediction of given the past of and of all other signals. Let be the target’s value at prediction instant , and the row of regressors built only from data before : an intercept, ’s own past and a block of regressors for every source (§ 1.1.2). Stacking the prediction instants gives the vector and the matrix . The coefficients are estimated by least squares,
the prediction of at instant is
and the residual sum of squares over the prediction instants is
is the residual sum of squares of the restricted model, computed in the same way without ’s block. Because adding regressors cannot increase the residual sum of squares of a least-squares fit, . The strength of the edge is its size, the partial : the share of the variance left unexplained by the restricted model that ’s block explains,
which lies between 0 and 1. Even when has no influence on , is not exactly 0: by chance ’s block explains a little, and more so the more columns it has and the fewer instants there are. An edge is therefore declared only when is larger than chance would give for the columns of ’s block and the prediction instants, judged by
which follows an distribution with and degrees of freedom when there is no edge, being the number of columns of . This is the conditional Granger test (Geweke [29]; Lütkepohl [42]); its -value enters the decision rule below. The resulting graph is a summary Granger causality graph in the sense of Eichler [23]: an edge states that depends on ’s past within the span of its windows (at most 16 s), given the past of all other signals, without resolving the lag at which the dependence acts. Dependence within the same bin is not represented, because every regressor is built from data before the prediction instant.
Decision rule. Every candidate edge is an ordered pair : and are separate pairs, and the stimulus is never a target; denotes the number of such pairs. Edges are decided from the pairs’ -values by the Benjamini–Hochberg procedure (Benjamini and Hochberg [12]): the -values are sorted, ; is the largest index with ; and the pairs with the smallest -values are declared edges (none if there is no such ). This keeps the expected share of false edges among the declared ones, the false discovery rate (FDR), at or below 5% when the tests are independent or positively dependent; tests computed on the same recording are dependent, so the 5% is approximate. The stricter Bonferroni rule () would bound the chance of any false edge but miss more true ones.
Rate-matched Granger causality
Levels, bins and home levels. A node’s sampling rate, the resolution at which its samples enter the analysis after any block averaging (Table 1), is distinct from its acquisition rate and from the timescale of the process it measures: a fast signal can carry slow information, such as the power of an EEG rhythm. Signals at different rates cannot be predicted at common instants without resampling. RMG C instead defines three regular time grids, or levels, with steps of 20 ms, 200 ms and 2 s (50, 5 and 0.5 Hz: fast, medium, slow). The interval between two consecutive grid points, , is a bin, and a signal’s value in a bin is the mean of its samples in it. Each signal has a home level: the fastest level not faster than its sensor, so that every bin contains at least one sample. The heartbeat is assigned to the medium level and the stimulus to the fast level. Each signal is predicted only at its home level, bin by bin, by its own least-squares model (§ 1.1.1); we call the signal being predicted the target.
Own past. The target’s own past enters its model as its values in the previous bins: 15, 20 and 8 bins at the three levels, that is 0.3 s, 4 s and 16 s. These spans are fixed a priori to cover each level’s own dynamics: EEG rhythms within 0.3 s, breathing cycles and heart-rate responses within 4 s, slow autonomic drifts within 16 s. They are not tuned; halving or doubling them, together with the window horizon, leaves the results essentially unchanged (§ 8.2).
Window pooling. Every other signal contributes to the target’s model a block of regressors computed from ’s samples as recorded, at ’s own rate, without interpolating them onto the target’s grid. The samples are grouped into time windows that end before the target bin starts, so that only the past is used (the windows are causal). For a target bin starting at , window is , where the window edges are multiples of the bin width of the target’s level:
The first 8 windows have the target’s bin width; after that the widths double, so the windows are fine near the present and coarse further back (Table S3). The furthest window ends 10.24 s, 12.8 s and 16 s before the target bin at the three levels. Windows narrower than a source’s sampling interval are merged with the next, so no window is empty and slow sensors contribute their freshest samples. Window contributes the mean of ’s samples in it, ; heartbeats contribute the rate of each completed beat and the stimulus the number of beats. A fast signal contributing to a slower target (sampled at least four times faster than the target’s level) gives a second value per window, the logarithm of the variance of its samples, , its power; this power channel is what lets an edge from fast power to a slow signal be found. Mean and power belong to the same node: whether the mean or the power of improves the prediction of , the edge is .
| Level | Bin width | Window edges (s) | Near | Middle | Far |
| fast (50 Hz) | 0.02 s | 0, 0.02, 0.04, 0.06, 0.08, 0.1, 0.12, 0.14, 0.16, 0.32, 0.64, 1.28, 2.56, 5.12, 10.24 | 0–0.08 s | 0.08–0.32 s | 0.32–10.24 s |
| medium (5 Hz) | 0.2 s | 0, 0.2, 0.4, 0.6, 0.8, 1, 1.2, 1.4, 1.6, 3.2, 6.4, 12.8 | 0–0.6 s | 0.6–1.4 s | 1.4–12.8 s |
| slow (0.5 Hz) | 2 s | 0, 2, 4, 6, 8, 10, 12, 14, 16 | 0–4 s | 4–10 s | 10–16 s |
Table S3. Window edges for a source sampled at least as fast as the target’s level, and the three summaries used by the quadratic and RMGC-NN variants (§ 9.1). Slower sources have narrow windows merged.
Aliasing. A window mean is an average followed by one value per window, so fast oscillations can alias into it; the box-car average attenuates frequencies above the inverse window width only moderately. This does not create false edges in the Granger sense: the window values are functions of ’s own past samples, so if they improve the prediction of , ’s past does. Aliasing changes which aspect of the test sees, not the validity of the test. The bins must, however, be short compared with the coupling delays of interest (§ 8.2). Figure 1 shows the design. With least-squares fits and the test of § 1.1.1, this is the core of the method, rate-matched Granger causality (RMGC).

Figure 1. RMGC. Inputs (left): the signals at their own rates, grouped by the level that matches their sampling rate. Models (middle): each signal is predicted at its level by its own least-squares model; every model uses causal windows of all signals’ own past samples, and the power of fast signals. Output (right): one directed graph, with an edge when ’s block of regressors is significant for ( test per source, Benjamini–Hochberg over the pairs), within or across timescales; the edges shown are an example. The hidden-driver attack (bottom) takes each declared edge and returns its robustness value.
Source blocks. The window values (and ) of one source form that source’s block. Each block is tested by the test of § 1.1.1, with all other blocks and the target’s own past kept; if ’s block is significant in ’s model, the edge is declared.
Bin pooling. Bin pooling, which we report as an ablation, represents every source at the target’s level instead: faster sources as their bin means and powers, slower sources as their last completed bins, each with the level’s number of lags. Window pooling is preferred for two reasons. It needs fewer regressors: in the benchmark, a medium-level target has 169 regressors with bin pooling and 98–105 with window pooling, and fewer regressors give the tests more power. And with bin pooling, slow sensors enter only through their completed 2-s bins, so a faster signal such as heart rate can carry fresher information about a hidden driver than the slow sensor itself.
Nonlinear extension
Two variants add nonlinear effects; § 9.1 of the supplement gives the details. The quadratic variant adds the squares of the standardized source summaries and tests them with the same
test. RMGC-NN keeps every linear test and adds an out-of-sample test of whether a small network on the source’s summaries improves the prediction of the target’s residuals; an edge is declared on linear or nonlinear evidence. We use RMGC as the default and report the nonlinear variants as extensions.
Robustness value by attack
For a declared edge of size , the attack asks how strong a hidden driver would have to be to produce an edge of that size if had no influence on . The strength of a driver added to a signal as is its variance share,
In each signal it is measured on the values through which that signal enters ’s model: in the target on its bins, which the model predicts, and in the source on its window values, which the model uses as regressors, taking the window where the driver is strongest, . A slow driver therefore counts at full strength in the slow windows, where it can dominate a fast signal such as EEG, even if it is small in the narrowest window. The attack has three steps.
Remove the edge. The fitted contribution of ’s block is subtracted from ’s current values, keeping ’s own past as observed, so that ’s block explains exactly nothing. (’s own past is kept as observed because rebuilding it from the edited series would carry ’s influence back into the model.)
Add a driver. A unit-variance driver is added to with delay s and to ’s bins and own past with delay (receiving the driver first is the only way it can make appear to drive ), with variance share in and in . In the driver is added to the window means, and for a source with a power channel the same series is added to its log-variance values.
Refit and search. ’s model is refitted and ’s block size measured. Along a ray of fixed share ratio , a coarse scan over the larger share (nine values from 0.01 to 0.95) finds the first interval in which the size reaches , and seven bisection steps refine it; the scan keeps the search valid even if the size does not grow steadily as the driver gets stronger.
The driver class has 20 members built from four base drivers: Ornstein–Uhlenbeck processes with persistence 2 or 10 s, and damped oscillators at 0.1 Hz (like Mayer waves; [38]) and 0.25 Hz (like breathing) with a 10-s damping time. Each acts on both signals linearly, with delay differences of 0.5, 1 and 2 s (12 members), or through its square, , or through saturation, , with a delay difference of 1 s (8 members). The robustness value (RV) of the edge is the smallest value of the larger share, , over the drivers of this class that produce the edge. All 20 drivers are searched with equal shares, and the three cheapest also with share ratios of 1/4, 1/2, 2 and 4. If no driver in the class produces the edge with a share of at most 0.95, the RV is set to 1; such an edge was not reproduced within the searched range, which is distinct from a driver reproducing it at a large share. A low RV means that a weak driver in the class sufficed to reproduce the edge; a high RV means that no weak driver was found in the class, not that none exists. Drivers outside the class (other persistences or delays, other nonlinear forms) might produce the edge with a smaller share, so the RV is an upper bound on the smallest share over all possible drivers. Sources the driver does not touch are partialled out once per edge ([41]), so each bisection step is a small regression; the results are identical to refitting the full model.
Benchmarking against a measured driver. Following Cinelli and Hazlett [18], the RV is compared with a driver that is measured, breathing, whose share is defined in the same way: in , the largest of ’s window values on breathing’s windows (); in , the of ’s bins on breathing’s windows (), both in ’s model with breathing. The breathing multiple is the strength a hidden driver needs, in units of breathing’s; means that a hidden driver as strong as breathing’s largest effect on the two signals could produce the edge. In short, measures how much ’s past improves the prediction of ; the RV, how strong a hidden driver would have to be to produce an edge of size if had no influence on ; and , that strength in units of breathing’s.
Evaluation design
Benchmark. A simulator with known ground truth (Section S1) generates seven observed signals at the rates of real sensors: a rhythmic stimulus, two EEG-like signals at 250 Hz, breathing at 25 Hz, heartbeats as events, an fNIRS-like signal at 8 Hz and skin conductance at 4 Hz, with six true edges within and across timescales, among them a fast-to-slow edge carried by EEG power. Eight scenarios (clean; hidden arousal and hidden breathing, each mild and strong; a stimulus tempo near heart rate; volume conduction between EEG sensors; a squared edge) have eight replicates of 10 min each, 64 in all, with fixed seeds. The scenarios contain traps: edges produced by hidden drivers, the reversed edge HR → RESP and the indirect edge SC → EEG2 that common grids create, and mixing between EEG sensors. We report recall, the false-positive rate over non-edges and the share of replicates declaring each trap edge; five success criteria were fixed in advance (Section S1).
Matched comparison. The central comparison gives the established methods the same information as RMGC: a vector autoregression on common grids at 50 and 2 Hz (grid VAR), multiscale Granger causality (Faes et al., [26]) and PCMCI (Runge et al., [53]), each with the EEG power columns that RMGC uses and with one test per ordered pair (Bonferroni over the pair’s grids and columns, then one Benjamini–Hochberg procedure over the pairs). The comparison with the methods as published, including neural Granger causality and LPCMCI, the fairness experiment and the sensitivity analyses are in the supplement (§ 7 and § 8). We did not compare with MIDAS regressions or mixed-frequency Granger tests ([30, 32]) directly: they require regular sampling in a fixed ratio of frequencies and test a few series at a time, whereas the benchmark includes event streams and non-integer rate ratios and calls for a graph over seven signals; their multivariate form, a VAR on stacked high-frequency samples, is close to the grid VAR on its finest grid. § 7 explains why VARX was not run separately either.
Ablations and calibration. Three ablations each remove one component of RMGC: the power channel; rate matching, with every signal interpolated to 50 Hz; and window pooling, with every source represented at the target’s bins (bin pooling). Calibration was checked on a null scenario, the clean scenario with every edge and the stimulus effect removed, in 64 replicates.
Uncertainty. Intervals are 95% percentile bootstrap intervals ([22]) (2000 resamples), resampling replicates within scenarios for the benchmark, and recordings or participants for the real data.
Overnight sleep recordings
We used the healthy-subject recordings of the CAP Sleep Database ([59, 31]); the six with a breathing channel (n1, n4, n6, n7, n8, n9) were analysed. The signals were two EEG derivations (one central, one occipital or parietal where available; about 128 Hz, with power values at slower levels), breathing (thoracic belt, or nasal airflow for n8, whose thoracic channel was dominated by drift; about 25 Hz), heart rate from the R-peaks of the electrocardiogram, and oxygen saturation when present (n1 only). Each night was cut into 10-min segments within one sleep-stage group (wake, light non-rapid-eye-movement (NREM) sleep, deep NREM sleep, rapid-eye-movement (REM) sleep; at most 6 per group; a final segment of at least 8 min was kept). Segments with more than 5% implausible heartbeat intervals, or more than 10% of 2-s EEG blocks with extreme amplitude, were skipped.
In every segment RMGC was run twice: with breathing, and with breathing hidden (removed from the model); we call this the hide-breathing test. Every edge of the hidden run received its RV, and breathing’s share in each signal was estimated from the breathing run. Edges present only in the hidden run we call breathing-sensitive: they appear when breathing is omitted, which suggests, but does not prove, that breathing contributes to them. An edge counts as breathing-sensitive only if its -value in the hidden run passes the Benjamini–Hochberg threshold of the run with breathing (, with the number of declared and the number of tested pairs), so that it cannot appear merely because the threshold moved with the number of pairs. As a control, a placebo, a copy of breathing shifted by half its stream’s span, was added to the model and hidden in the same way. Surrogates without coupling gave the base rate of brain–body edges: the EEG of one recording with the other signals of another, in segments of the same sleep stage. Edges present in both runs we call stable; stability says nothing about their physiological validity. The test is whether the breathing multiple is small for the breathing-sensitive edges and large for the stable ones.
Awake recordings: BBBD
The Brain, Body, and Behavior Dataset (BBBD; [43]) contains simultaneous EEG (64 channels), ECG, EOG, respiration and eye tracking from participants watching short educational videos; all signals are released at 128 Hz. Experiments 4 and 5 recorded respiration: 43 and 48 participants, each with six recordings of one video (2.4–6.5 min; in experiment 5 the same three videos twice, the second time with an incentive). Nodes: four regional EEG averages (left and right frontal: F3, F5, F7, FC3, FC5 and their right counterparts; left and right parietal: P3, P5, P7, CP3, CP5 and theirs; average reference), breathing (chest belt, averaged to 25.6 Hz), heart rate from the hand-corrected R-peaks, pupil size (averaged to 25.6 Hz), and the EOG, the first principal component of the six EOG channels, as a node for eye activity, which reaches both the EEG and the measured pupil. A recording was skipped if its heartbeats, EEG, breathing, pupil or EOG failed quality criteria of the same kind as for the other data sets. The hide-breathing test, with its fixed threshold and placebo, was as for the sleep recordings, and the surrogates as described below for both awake data sets; for the cross-participant surrogate, recordings of the same video line up exactly. The established methods were run on each participant’s first recording of session 1, a subset fixed in advance. Prevalence was computed per experiment.
Stress test: MultiPhysio-HRC
MultiPhysio-HRC serves as a stress test: its recordings, made with a dry-electrode headset during tasks that include movement, strain the method’s assumptions more than the other data sets. We used the raw physiological data of MultiPhysio-HRC ([14]): 52 participants in the released data (the article reports 55 on the first day) recorded at 256 Hz with a 12-electrode dry EEG headset and a sensor for the electrocardiogram, a chest respiration band, skin conductance and trapezius EMG, synchronized by the acquisition software. On a first day each participant performed rest, guided breathing, five cognitive tasks (Stroop easy and hard, N-back, mental arithmetic, Tower of Hanoi) and two virtual-reality tasks; on a second day (42 participants), rest and repeated manual and robot-assisted (cobot) disassembly tasks. Each task recording was split by repetition into segments, stretches analysed one at a time like the sleep segments, and segments of at least 2 min were analysed (median 4.1 min, up to 25 min). The nodes are listed in Table 1. Segments with more than 5% implausible heartbeat intervals, a flat signal, or more than 10% of 1-s EEG blocks with extreme amplitude were skipped. The hide-breathing test, with its fixed threshold and placebo, was the same as for the sleep recordings. In the guided-breathing task, breathing heart rate is a known edge and serves as a positive control. Results are reported by task group, rest (both days), guided breathing, cognitive (the five cognitive tasks), virtual reality (both tasks), manual and cobot (the repeated disassembly tasks), and by edge type: EEG–EEG, brain–heart, brain–other body signals and body–body.
The established methods were run with and without breathing on a subset fixed in advance, rest (rest_0) and guided breathing (meditation_0) of every participant, because running them on every segment would have taken weeks; LPCMCI had the same 30-s limit.
Surrogates and timing. Two surrogates without coupling gave base rates of brain–body edges in both awake data sets: the EEG of one participant with the other signals of another during the same task, and each participant’s own body signals shifted circularly by half the segment against their EEG, which keeps every signal and destroys only their alignment. The trapezius EMG was high-pass filtered causally. Block means are stamped at the end of their block, and stay stamped at their block’s end in the time-reversed recording.
Results
Detection on the benchmark
Given the same power features and one test per pair (Table 2, Figure 2), RMGC reached a recall of 0.92 at a false-positive rate of 0.05. The grid VAR matched its recall (0.92) at 2.4 times its false-positive rate (0.12), and declared the reversed edge HR RESP in every replicate and the indirect edge SC EEG2 in every replicate outside volume conduction. Multiscale Granger causality kept fewer false positives (0.04) but found far fewer true edges (0.68), and PCMCI fell between (0.78 and 0.10). RMGC declared the reversed edge in 4% and the indirect edge in 2% of the replicates. Without power features, as published, the established methods reached recalls of 0.43–0.77 and missed most of the fast-to-slow edge (Table S7). RMGC met success criteria 1–3; criterion 4, an AUC of the robustness value of at least 0.8, is narrowly missed by RMGC (0.7996) and met by RMGC-NN (0.805). The nonlinear variants matched RMGC’s recall and false-positive rate (0.93 and 0.05) and found the squared edge (§ 9.1). Figure 3 shows example graphs.
| Method | Recall | False-pos. rate | AUC | Cross-scale | Reversed HRRESP | Indirect SCEEG2* |
| Grid VAR + power | 0.92 | 0.12 | 0.96 | 0.97 | 1.00 | 1.00 |
| Multiscale GC + power | 0.68 | 0.04 | 0.92 | 0.57 | 0.00 | 1.00 |
| PCMCI + power | 0.78 | 0.10 | 0.93 | 0.76 | 0.10 | 0.77 |
| Grid VAR | 0.73 | 0.12 | 0.88 | 0.50 | 1.00 | 1.00 |
| Multiscale GC | 0.66 | 0.04 | 0.84 | 0.48 | 0.00 | 1.00 |
| PCMCI | 0.68 | 0.10 | 0.86 | 0.50 | 0.10 | 0.80 |
| RMGC | 0.92 | 0.05 | 0.98 | 0.93 | 0.04 | 0.02 |
| RMGC, quadratic | 0.93 | 0.05 | 0.98 | 0.97 | 0.04 | 0.00 |
| RMGC-NN | 0.93 | 0.05 | 0.98 | 0.97 | 0.04 | 0.02 |
Table 2. The matched comparison: the grid methods with EEG power columns and one test per pair (Bonferroni over each pair’s grids and columns, then one Benjamini–Hochberg procedure over the 36 pairs), without power, and the RMGC variants (64 replicates). *Outside the volume-conduction scenario.
Figure 2. Recall against false-positive rate in each of the 64 benchmark replicates, for RMGC and the established methods given the same EEG power features and one test per pair. Large markers: means. Dotted line: a false-positive rate of 0.05.
Figure 3. Example graphs. Colours: blue, true edges and red, false edges (b, c); green, stable edges and orange, breathing-sensitive edges (d); grey dotted, edges from breathing; grey dashed, the hidden arousal (a). (a) True graph of the nonlinear-edge scenario. (b) Edges declared by the union of common grids in one replicate, and (c) by RMGC-NN in the same replicate, with robustness values. (d) One deep-NREM segment of recording n1: edges from breathing in the run with breathing, and the edges of the hidden-breathing run with their breathing multiples .
| Scenario | Grids (union) | Multiscale GC | Neural GC | PCMCI | LPCMCI | RMGC | RMGC, quadratic | RMGC-NN |
| Clean | 0.73 / 0.09 | 0.62 / 0.04 | 0.79 / 0.06 | 0.60 / 0.10 | 0.50 / 0.02 | 0.90 / 0.02 | 0.92 / 0.01 | 0.90 / 0.02 |
| Hidden arousal | 0.71 / 0.11 | 0.56 / 0.04 | 0.75 / 0.12 | 0.65 / 0.05 | 0.44 / 0.03 | 0.92 / 0.02 | 0.88 / 0.01 | 0.88 / 0.03 |
| Hidden arousal, strong | 0.83 / 0.14 | 0.75 / 0.04 | 0.85 / 0.15 | 0.77 / 0.08 | 0.50 / 0.05 | 1.00 / 0.06 | 1.00 / 0.05 | 1.00 / 0.07 |
| Hidden breathing | 0.75 / 0.08 | 0.75 / 0.08 | 0.75 / 0.14 | 0.75 / 0.10 | 0.34 / 0.06 | 1.00 / 0.02 | 1.00 / 0.02 | 1.00 / 0.02 |
| Hidden breathing, strong | 0.75 / 0.21 | 0.75 / 0.09 | 0.75 / 0.20 | 0.78 / 0.18 | 0.25 / 0.10 | 0.97 / 0.12 | 0.97 / 0.10 | 0.97 / 0.12 |
| Tempo near heart rate | 0.75 / 0.09 | 0.67 / 0.03 | 0.79 / 0.12 | 0.71 / 0.08 | 0.54 / 0.08 | 0.98 / 0.03 | 0.94 / 0.03 | 0.94 / 0.03 |
| Volume conduction | 0.75 / 0.17 | 0.62 / 0.04 | 0.81 / 0.10 | 0.62 / 0.15 | 0.48 / 0.06 | 0.90 / 0.12 | 0.90 / 0.12 | 0.88 / 0.11 |
| Nonlinear edge | 0.62 / 0.09 | 0.50 / 0.03 | 0.66 / 0.13 | 0.62 / 0.06 | 0.41 / 0.04 | 0.73 / 0.02 | 0.88 / 0.03 | 0.88 / 0.02 |
| Mean recall | 0.74 | 0.65 | 0.77 | 0.69 | 0.43 | 0.92 | 0.93 | 0.93 |
| Mean false-positive rate | 0.12 | 0.05 | 0.13 | 0.10 | 0.05 | 0.05 | 0.05 | 0.05 |
| Mean AUC | 0.88 | 0.86 | 0.84 | 0.86 | 0.68 | 0.98 | 0.98 | 0.98 |
| Mean cross-scale recall | 0.50 | 0.48 | 0.51 | 0.51 | 0.51 | 0.93 | 0.97 | 0.97 |
Table S7. Established methods against the RMGC variants: recall / false-positive rate per scenario and means over the 64 replicates (eight per scenario); best values per row in bold.
Ablations and calibration
Each component of RMGC mattered (Table 3). Without the power channel, cross-scale recall fell from 0.93 to 0.49, and the fast-to-slow edge EEG2 fNIRS was found in 2% of the replicates instead of 94%. Interpolating every signal to 50 Hz brought the reversed edge HR RESP back in every replicate and raised the false-positive rate from 0.05 to 0.12. Bin pooling kept the overall recall (0.90) but lowered medium-scale recall from 0.80 to 0.68. In 64 null replicates (Table S14), RMGC declared a false edge in 1 (1.6%; 95% interval 0.3–8.3%), consistent with the 5% expected under the global null; the quadratic variant and RMGC-NN in 6 and 5, and multiscale Granger causality in 6, all consistent with 5%; the grid VAR in 8 (12.5%; 6.5–22.8%) and PCMCI in 23 (36%), both significantly above it. Sensor rates that do not match the levels and halved or doubled lag spans left RMGC’s recall at 0.91–0.93; coarser levels, with bins longer than the breathing-to-heart delay, brought the reversed edge back (§ 8).
| Variant | Recall | False-pos. rate | Medium recall | Cross-scale | EEG2→fNIRS found | Reversed HR→RESP | Indirect SC→EEG2 |
| Full RMGC | 0.92 | 0.05 | 0.80 | 0.93 | 0.94 | 0.04 | 0.14 |
| Without power | 0.75 | 0.05 | 0.77 | 0.49 | 0.02 | 0.02 | 0.14 |
| Interpolated to 50 Hz | 0.71 | 0.12 | 0.60 | 0.50 | 0.05 | 1.00 | 0.14 |
| Bin pooling (no windows)* | 0.90 | 0.05 | 0.68 | 0.94 | 0.88 | 0.00 | 0.16 |
Table 3. Ablations of RMGC (64 replicates). *Seven scenarios (the bin-pooling version was not run on the nonlinear scenario).
| Method | Replicates with a false edge | 95% interval | False edges per replicate | |
| RMGC | 1 of 64 (1.6%) | 0.3–8.3% | 0.96 | 0.016 |
| RMGC, quadratic | 6 of 64 (9.4%) | 4.4–19.0% | 0.10 | 0.094 |
| RMGC-NN | 5 of 64 (7.8%) | 3.4–17.0% | 0.22 | 0.078 |
| Grid VAR + power | 8 of 64 (12.5%) | 6.5–22.8% | 0.01 | 0.156 |
| Multiscale GC + power | 6 of 64 (9.4%) | 4.4–19.0% | 0.10 | 0.094 |
| PCMCI + power | 23 of 64 (35.9%) | 25.3–48.2% | 0.00 | 0.516 |
Table S14. Null scenario, extended to 64 replicates for the methods of the matched comparison (no edges; 36 candidate pairs each). : probability of at least as many replicates with a false edge if the rate were 5%.
Validity and discrimination of the robustness value
Benchmark. Across 64 replicates (eight of each scenario), RMGC declared 344 edges between nodes (265 true, 36 faked by a hidden driver, 43 other false). Every faked edge had an RV at most the actual share of the driver that produced it, measured by the same definition with the simulator rerun without the driver’s edges (36 of 36; 28 of 28 for RMGC-NN). The RV separated true from faked edges with AUC 0.80 [0.74, 0.85] (0.80 for RMGC-NN), against 0.40 (0.39) for edge size; criterion 4 (AUC of at least 0.8) is met by RMGC-NN (0.805) and narrowly missed by RMGC (0.7996). Edge size alone was misleading: under strong hidden arousal every faked edge was larger than every true one (AUC 0.00), where the RV gave 0.64. The median RV was 0.15 for true and 0.07 for faked edges. It was high for the fast edge EEG1 → EEG2 (0.70) and low for small true edges such as RESP → fNIRS (0.06) and the fast-to-slow power edge (0.08), which were as easy to fake as the faked edges themselves (medians 0.01–0.10). The drivers that set the RV, those reproducing the edge with the smallest share, were mostly oscillators, acting linearly, through their square or through saturation. Relative to breathing (Figure 4b), on the 141 true and 16 faked edges where breathing was observed, the breathing multiple separated them with AUC 0.94 [0.92, 0.96] (RV alone 0.73, size 0.17); for 56% of the faked edges and 4% of the true ones. With the nonlinear attack’s coarse scan, edges supported only by nonlinear evidence had RVs of 0.05–0.47 when true (the squared edge) and 0.01–0.46 when false (AUC 0.78).
Figure 4. (a) Robustness values of true and faked edges in the benchmark (RMGC). (b) Breathing multiples of the same edges where breathing was observed; dotted line: as strong as breathing. (c) Sleep, (d) BBBD and (e) MultiPhysio-HRC: breathing multiples of the brain–heart edges of the runs without breathing, stable and breathing-sensitive. Black bars: medians.
Drivers outside the class. The RV stayed valid for drivers the attack does not search. Under the 60-s drift, faked edges appeared in all 8 replicates with RVs of 0.03–0.07, below the actual larger shares of 0.77–0.93, and the RV separated them from true edges (AUC 0.90). Under the
######## Null scenario amplitude-modulating oscillation, the faked edge EEG2 HR appeared in all 8 replicates with RVs of 0.17–0.27, below the actual larger shares of 0.51–0.63, but the RV did not separate it from true edges (AUC 0.36): a driver that acts in a way the class cannot mimic makes a faked edge look as robust as a true one.
Empirical controls in real data
Table 4 summarizes the controls for the three data sets. The positive control, breathing heart rate, was declared in 93% of the sleep segments, 99% of the BBBD recordings and 59% of the MultiPhysio-HRC segments (82% during guided breathing). Omitting breathing made new edges appear at the fixed threshold: 38 in sleep against 5 for the placebo, 369 against 148 in BBBD, and 670 against 424 in MultiPhysio-HRC. Surrogates without coupling gave background rates of brain–heart edges of 4% in sleep and 2% in BBBD, against 34% and 7% in the real recordings; in MultiPhysio-HRC the background was 12%, against 28%. The controls in sleep and BBBD therefore support reading their edges against a low background; in MultiPhysio-HRC, recorded with dry electrodes during tasks that include movement, they do not, and its edges are read against its background rates (Section S5). Time reversal kept the anterior-to-posterior direction between the two EEG derivations increasingly with sleep depth, from 11% of the wake segments to 71% of the deep NREM ones, as expected from slow oscillations (§ 9).
| Data set | Segments | Breathing heart rate | Edges after omitting breathing | Placebo | Brain–heart, background | Brain–heart, real |
| Sleep (CAP) | 115 | 93% | 38 | 5 | 4% | 34% |
| BBBD | 518 | 99% | 369 | 148 | 2% | 7% |
| MultiPhysio-HRC | 557 | 59% | 670 | 424 | 12% | 28% |
Table 4. Empirical controls in the three data sets: analysed segments, the positive control (breathing heart rate declared), edges that appear when breathing is omitted and when the placebo is omitted (at the fixed threshold of the full run), and brain–heart edges declared in surrogates without coupling (background; for sleep, the EEG of another recording; for the awake data, body signals shifted circularly) and in the real recordings, as shares of the possible ones.
Brain–heart robustness across data sets
Table 5 compares brain–heart edges (EEG heart rate) across the three data sets with one definition. In sleep, breathing-sensitive brain–heart edges needed a median of 0.42 times breathing’s share and stable ones 1.01; about half of the stable ones (49%) could be produced by a hidden driver as strong as breathing, and the breathing multiple separated the two groups with AUC 0.75, about as well as edge size (0.70). In both awake data sets brain–heart edges were more fragile: stable ones needed a median of 0.37 (BBBD) and 0.38 (MultiPhysio-HRC) times breathing’s share, and 94% and 79% of them had ; the breathing multiple separated breathing-sensitive from stable brain–heart edges only weakly (AUC 0.63 and 0.65, against 0.68 and 0.54 for edge size). BBBD passes the surrogate check and MultiPhysio-HRC does not, so this fragility does not come from the recording conditions: in both awake data sets, a hidden driver weaker than breathing could produce most brain–heart edges. On all three data sets, the edges RMGC-NN added were mostly breathing-sensitive and fragile (§ 9).
| Data set | Stable / sensitive | (stable / sensitive) | AUC: / size | Median (stable / sensitive) |
| Sleep (CAP) | 152 / 37 | 49% / 84% | 0.75 / 0.70 | 1.01 / 0.42 |
| BBBD | 179 / 123 | 94% / 98% | 0.63 / 0.68 | 0.37 / 0.30 |
| MultiPhysio-HRC | 1038 / 171 | 79% / 92% | 0.65 / 0.54 | 0.38 / 0.17 |
Table 5. Brain–heart edges (EEG heart rate) of the runs without breathing, with one definition for the three data sets: stable and breathing-sensitive edges, the shares with breathing multiple , AUC separating the two groups (breathing multiple, edge size) and median breathing multiples.
Discussion
Rate matching and physiological timescales
Rate matching avoids the errors that resampling creates. The common-grid failures in the benchmark are all consequences of putting signals with different rates and timescales on one grid: a coarse grid turns a fast relation into an instantaneous one and an indirect path into a direct edge, a fine grid needs too many lags for slow relations, and held or interpolated samples reverse edges. Predicting each signal at its own rate and letting every source enter through windows of its own samples removes these errors without new statistical machinery: RMGC uses ordinary least squares and tests. The fairness experiment and the ablations confirm the diagnosis and separate the contributions: given the same power features, a VAR on common grids matches RMGC’s recall but not its false-positive rate, and it keeps the reversed and indirect edges; interpolating the inputs onto one grid brings the reversed edge back into RMGC itself, while the indirect edge is avoided by the long causal history of the windows, with or without rate matching. The fast-to-slow edge, by contrast, needs power information, which any method can be given. Passing fast signals to slower levels as power is what makes fast-to-slow coupling visible, a mechanism that matters for neurovascular and brain–body questions where slow signals follow neural power, not raw voltage.
Beyond physiology. Nothing in RMGC or in the attack is specific to physiological signals. The approach applies whenever five conditions hold.
Several signals cover the same period, each recorded at its own rate, irregularly, or as event times.
Influences act with a delay, so that a source’s past can be told apart from the target’s present, and the question is which signals help predict which (Granger-type edges), not what an intervention would do.
Within each analysed segment the relations are stable enough, and the segment long enough, to span many times the longest window used (16 s here; months, years or decades elsewhere).
The influences are linear, or nonlinear in ways that power, squared or small-network terms can represent.
For robustness values to be interpretable, plausible hidden drivers can be described by their persistence or rhythm, and at least one candidate driver is measured, to serve as a benchmark.
Econometrics is the most direct case. Macroeconomic and financial series arrive daily, monthly and quarterly; aggregating them to the lowest common frequency is known to distort Granger causality, and mixed-frequency tests were developed for exactly this reason [30, 32]. Averaging high-frequency data over windows of increasing length is also an established device there, in models of realized volatility [19], and sensitivity analysis benchmarked against an observed variable comes from the same tradition [18]. What RMGC adds to these tools is a graph over many signals with multiple-testing control, signals sampled at any rate or recorded as events rather than at regular intervals in a fixed ratio of frequencies, separate levels for each timescale, explicit cross-scale edges and per-edge robustness to hidden drivers. Other fields meet the same conditions. Climate and environmental monitoring combines instruments sampled every second with daily measurements and slow proxies. Industrial monitoring combines fast vibration or current sensors with slow process variables and alarm events. Historical analysis works with annual prices or harvests, censuses every ten years, and dated events such as wars, epidemics or reforms, records in which hidden common drivers such as climate or institutions are the rule rather than the exception. The conditions also mark the limits, which our real data illustrate: short or strongly changing series, influences that are mostly instantaneous at the available resolution, and aggregate measures that mix several underlying sources (the analogue of volume conduction) all weaken the method.
Interpreting robustness values
The robustness value is valid in simulation; it discriminates only with a benchmark and enough data. No method avoided strong hidden drivers, and edge size was misleading: slow, persistent drivers fake large edges cheaply. The robustness value was valid in the benchmark, also for drivers outside the searched class, and consistent with most breathing-sensitive edges in all three data sets ( for 84% in sleep, 59–100% in BBBD and 83–92% in MultiPhysio-HRC). It discriminated well in the benchmark (AUC 0.80, and 0.94 relative to breathing), moderately in sleep (0.88 overall, 0.75 within brain–heart edges) and weakly in the awake recordings (0.48–0.63 in BBBD, 0.58–0.66 in MultiPhysio-HRC). Comparing with a measured driver mirrors sensitivity analysis in regression [18]: the useful question is not whether an edge could be confounded but whether a confounder as strong as a known one could explain it. Drivers that act in ways the class cannot mimic are the limit: an oscillation that modulates amplitude faked an edge that looked as robust as true ones, although its RV stayed below the driver’s actual share. Like the smallest perturbation that an attack finds against a classifier, which bounds the true minimum from above [15], the RV is an upper bound: drivers outside the searched class might produce an edge with a smaller share.
Breathing as a common pathway in brain–heart networks
In sleep, about half of the brain–heart edges are fragile. Most breathing-sensitive edges (84%) were within reach of a driver weaker than breathing, as they should be, but so was about half of the stable brain–heart edges, and 23% needed more than twice breathing’s strength. Within brain–heart edges the breathing multiple did not beat edge size. We read this as a substantive result: during sleep, many directed brain–heart edges between these signals could be produced by a hidden driver of breathing’s strength, so they should not be interpreted as direct neural control of the heart without further evidence. The bidirectional EEG edges in every segment are most likely shared activity or mixing between scalp signals [35]; robustness to hidden drivers cannot address them. Time reversal can: in half of the segments neither direction survived it, and where one did it was almost always anterior to posterior, increasingly so with sleep depth. On the same segments the established methods performed like RMGC; RMGC’s advantage on real data appeared in MultiPhysio-HRC, where the coupling was weaker and the segments shorter; in BBBD, every method except LPCMCI found breathing heart rate in 93–99% of recordings.
In awake tasks, brain–body edges are very fragile. A typical brain–heart edge needed a hidden driver only about 0.4 times as strong as breathing, against about 1.0 in sleep, and the breathing multiple separated breathing-sensitive from stable edges hardly better than edge size. The MultiPhysio-HRC recordings differ from sleep in ways that all point to fragility: segments of a few minutes with changing tasks, movement, dry electrodes, and more candidate hidden drivers (arousal, posture, muscle activity). The last point also weakens the test itself, because stable edges are probably confounded by drivers other than breathing and are a poorer reference than in sleep. Yet BBBD, with none of these conditions and an error rate that passed the surrogate check, gave the same picture: its stable brain–heart edges needed a median of 0.37 times breathing’s share, against 0.38 in MultiPhysio-HRC. In both awake data sets, whatever the recording conditions, a hidden driver weaker than breathing could produce most brain–heart edges. The positive control and the breathing shares, which do not depend on the attack, behaved as physiology predicts.
In BBBD the background rate in surrogates was low (2–3% of the possible brain–body edges), although its recordings are as short as MultiPhysio-HRC’s; there, recorded with dry electrodes during tasks with movement, 12% were still declared with the body signals shifted circularly against the EEG, against 2–4% in sleep. Background detection therefore depends on recording conditions rather than segment length, and circular-shift surrogates are a cheap check for any new data set. In MultiPhysio-HRC, short awake segments with drifts and task changes violate the stationarity the tests assume, and hiding a placebo gave almost two thirds as many new edges as hiding breathing. Awake edges must be read against these base rates. On the same awake segments, RMGC found the known breathing heart rate edge more often than the established methods, especially during guided breathing (82% against 32–68%; at rest 70% against 30–62%), but it also produced more breathing-sensitive edges: the sensitivity that finds real slow couplings also picks up slow common drivers, which is why per-edge robustness values are needed.
Limitations and future work
Limitations. In 64 null replicates RMGC’s false edges were consistent with a 5% false-discovery rate (1 replicate with a false edge), while the matched grid VAR and PCMCI exceeded it. On real data, surrogates gave low background rates in sleep and BBBD and about 12% of the possible brain–body edges in MultiPhysio-HRC; these rates are an empirical diagnostic of background detection, not the false-discovery rate of the real graphs. The robustness values are point estimates, without uncertainty. Drivers that act in ways the searched class cannot mimic, such as amplitude modulation, make faked edges look robust. The established methods ran on real data only on subsets fixed in advance (one segment per sleep stage and recording, each participant’s first BBBD recording, and rest and guided breathing in MultiPhysio-HRC), and LPCMCI was not feasible there within its time limit. Time reversal is proven valid only for unidirectional coupling between two variables ([63]); for pairs coupled in both directions, such as breathing and heart rate, its verdicts are unreliable. The benchmark is linear apart from the power and squared edges, has two hidden drivers and was calibrated by hand: its parameters were chosen, not fitted to data, and the strong variants were set to trap the baselines. Real physiology has artefacts and nonstationarity it does not contain. The attack’s class has four kinds of driver acting in three ways; the RV is an upper bound over it. LPCMCI ran on the coarse grid only, and the penalty of neural Granger causality was at the edge of the range tried. RMGC treats each recording separately; group conclusions rest on prevalence across participants. In the sleep data only two EEG derivations per recording were used because the montages differ; in all real data sets, stable edges are not ground truth. Edges are predictive, not interventional; only a stimulus provides true interventions.
Future work. Data sets with controlled stimuli ([61]), to test directions against interventions. Thresholds calibrated on surrogates, or detrending, for short nonstationary segments;
The neural extension on the real recordings
bootstrap intervals for the robustness values. A combination of the linear and nonlinear tests that gives most of the threshold to the linear one (a weighted Bonferroni correction), so that RMGC-NN loses fewer linear edges, and amplitude-modulating drivers in the attack’s nonlinear class, so that robustness values can flag breathing-mediated nonlinear edges. Learned spatial filters as EEG nodes: instead of fixed derivations or regional averages, each EEG node would be a weighted sum of all electrodes, with the weights learned together with the graph as a first layer of RMGC (constrained, for example, to be orthogonal, and shared across subjects), so that nodes approximate underlying sources rather than mixtures and volume conduction is reduced. Also: hierarchical models that pool edge sizes across subjects, and band-limited power channels.
Conclusions
Rate-matched Granger causality estimates directed graphs from signals recorded at different rates and acting on different timescales, without a common sampling grid. On a benchmark it found more true edges than vector autoregressions on common grids and four established methods, at an equally low false-positive rate; given the same power features, a grid model and neural Granger causality matched its recall but kept 2.4 to 3.5 times its false positives and the reversed and indirect edges that resampling creates. In the MultiPhysio-HRC recordings, where the coupling is weaker and the segments short, it found a known breathing-to-heart edge more often than the established methods; in sleep and in BBBD, the established methods except LPCMCI found it about as often. Its neural extension, RMGC-NN, finds nonlinear edges in simulation; on real recordings about half of the edges it adds come from breathing, and their robustness values flag them as fragile but cannot tell which, so we recommend RMGC as the default. The benchmark had several sources of false edges: coarse or resampled grids (indirect paths declared as direct, reversed edges), measurement noise, mixing between scalp signals, and hidden drivers. In the tested scenarios RMGC avoided the errors of coarse or resampled grids; time reversal removed much of the mixing, which ultimately needs better node definitions. Hidden drivers remain, and the robustness value assesses how sensitive each edge is to them, within the searched class. The robustness value was valid in simulation, also for drivers outside the searched class. Expressed relative to a measured driver such as breathing, it identified the false edges caused by hidden drivers reliably in simulation and moderately in sleep. In overnight recordings about half of the brain–heart edges could be produced by a hidden driver as strong as breathing; in the MultiPhysio-HRC tasks 70–79% of the stable brain–body edges could, as could 94% of the stable brain–heart edges in BBBD. The method’s false-positive rate held in BBBD but exceeded the nominal level in the MultiPhysio-HRC stress test. The approach is general: it applies whenever signals recorded at different rates or as events influence each other with delays, over segments long and stable enough for the slowest timescale, through effects its linear or nonlinear terms can represent, and, for robustness values, with a measured candidate driver to serve as a benchmark. Mixed-frequency economic data, climate and industrial monitoring, and historical records are examples.
Acknowledgements
LA was supported by UID/04516/NOVA Laboratory for Computer Science and Informatics (NOVA LINCS) with the financial support of FCT.IP. KF was supported by the Excellence Initiative – Research University programme awarded to the Nicolaus Copernicus University in Toruń.
Code and data availability
The code that produced all results (RMGC, the attack, the benchmark simulator, the comparators, the real-data pipelines, and the stored results from which every table and figure is generated) uses Python with NumPy, SciPy [62], statsmodels [54] and Matplotlib. It will be made publicly available upon acceptance of this paper and is available to reviewers on request. The CAP Sleep Database is available on PhysioNet [31], BBBD on Zenodo [43], and MultiPhysio-HRC as described by Bussolan et al. [14].
Simulator, benchmark and implementation details
####### Benchmark
Simulator. Latent nodes follow a continuous-time stochastic model integrated by the Euler–Maruyama method [40] with a 4-ms step, the sampling interval of the fastest sensors (250 Hz) and well below the shortest time constant (30 ms). A first-order node with time constant obeys
where the sum runs over the node’s incoming edges, from parent with strength and delay ; is the identity, the parent’s power envelope (for the power edge) or its square (for the squared edge); stimulus pulses enter in the same way; and is a standard Wiener process. The strength is thus the edge’s steady-state gain. A node without incoming edges is an Ornstein–Uhlenbeck process [60] with unit variance; incoming edges add variance. Breathing is a damped oscillator at 0.25 Hz. There are two fast EEG-like nodes (EEG1, EEG2; ms; EEG2’s noise amplitude varies slowly, so its power fluctuates), breathing (RESP), heart rate (HR, s), a node like a functional near-infrared spectroscopy signal (fNIRS, s), skin conductance (SC, s) and a hidden arousal node ( s). The heartbeat is generated by integrate-and-fire (integral pulse frequency modulation; Mateo and Laguna [45]) from the heart-rate node (about 70 beats per minute, 2-ms jitter), and a stimulus (STIM) delivers 20-ms pulses at 2 Hz. Sensors sample EEG1 and EEG2 at 250 Hz, breathing at 25 Hz, fNIRS at 8 Hz and skin conductance at 4 Hz, each with independent noise. Figure S1 shows 20 s of one recording.
Figure S1. Twenty seconds of one simulated recording, every stream at its own rate: stimulus beats, the two fast EEG-like signals (250 Hz), breathing (25 Hz), heartbeats with the instantaneous heart rate, the fNIRS-like signal (8 Hz) and skin conductance (4 Hz).
Edges and edge classes. The base system has six edges: STIM → EEG1 (50 ms); EEG1 → EEG2 (20 ms); SC → EEG1 (0.5 s); EEG2 → fNIRS through EEG2’s power (2 s, as in neurovascular coupling; Attwell et al. [3]); RESP → HR (0.5 s, respiratory sinus arrhythmia, 25% of heart-rate power; Berntson et al. [13]); RESP → fNIRS (1 s). An edge’s class is stimulus if its source is the stimulus, within fast or within medium if both signals belong to that timescale, and cross-scale if they belong to different timescales (SC → EEG1 and EEG2 → fNIRS). There is no within-slow class: skin conductance is the only observed slow signal, because arousal is hidden.
Scenarios. Table S1 lists the eight scenarios. Each has 8 replicates of 10 min. The scenarios with a hidden driver, arousal or breathing, come in a mild and a strong variant, which differ only in the driver’s strength.
| Scenario | Change from the base system | What it tests |
| Clean | none | sampling and measurement problems only |
| Hidden arousal | hidden arousal drives HR (1 s) and SC (3 s) | a hidden driver faking HR SC |
| Hidden arousal, strong | as above, loadings doubled | a hidden driver strong enough to trap the grids |
| Hidden breathing | hidden arousal; breathing measured but withheld from the methods | an oscillating hidden driver (HR fNIRS) |
| Hidden breathing, strong | as above; breathing’s effect on fNIRS 3.75 times larger, arousal loadings doubled | the same, strong enough to trap the grids |
| Tempo near heart rate | hidden arousal; stimulus at 1.2 Hz, the mean heart rate | a stimulus rhythm that matches the heart without driving it |
| Volume conduction | hidden arousal; the EEG1 and EEG2 sensors each record 0.4 of the other | mixing between scalp signals |
| Nonlinear edge | hidden arousal; SC acts on fNIRS through its square (1 s) | an edge invisible to linear tests in principle |
Table S1. Benchmark scenarios. All share the base system’s six edges.
Generator checks. Seven checks confirm that the generator does what the ground truth says, one for each mechanism: reproducibility, the two fast delays, the power coupling, respiratory sinus arrhythmia, the heart-rate level, and the hidden-driver coupling. Each is run with a fixed criterion on a separate 15-min simulation of the hidden-arousal scenario, longer than the benchmark recordings for more precise estimates (the hidden-driver check also on the clean scenario; Table S2); all pass.
| Check | Criterion | Result | Passed |
| Same random seed gives identical data | exact equality | identical | yes |
| Stimulus EEG1: lag of the strongest correlation | 50–120 ms (delay 50 ms + response) | 56 ms | yes |
| EEG1 EEG2: lag of the strongest correlation | 20–80 ms (delay 20 ms + response) | 32 ms | yes |
| EEG2 power fNIRS: lag and correlation | 2–4 s, | 3.1 s, | yes |
| Breathing heart rate: RR intervals shorten with breathing; share of heart-rate power at 0.2–0.3 Hz | at 0.5–2.5 s | at 1.5 s; 25% | yes |
| Mean heart rate of the heartbeat generator | within 8 beats/min of 72 | 71.6 beats/min | yes |
| Hidden arousal couples heart rate and skin conductance (without arousal: no coupling) | ; without: | ; without: | yes |
Table S2. Generator checks.
Calibration. The simulator’s parameters were set by hand, not fitted to data: time constants and strengths were chosen to give physiologically plausible signals (a heart rate near 70 beats per minute, respiratory sinus arrhythmia carrying a quarter of heart-rate power), and the strong variants were set so that the common-grid baselines fall into their traps in most replicates, while the mild ones keep the traps weak.
Metrics and success criteria. Recall per edge class, the false-positive rate over non-edges, the share of replicates declaring each trap edge (an edge a method may wrongly declare in a scenario, Table S6), the area under the receiver operating characteristic curve (AUC; [34]) of the edge scores (each method’s evidence for an edge; for the RMGC variants, of its -value), and split-half reproducibility (the Jaccard index ([37]) between the edges declared on each half of the recording). To judge whether the method works on the benchmark, five success criteria were fixed in advance; the method succeeds only if it meets all five. They concern its performance over all scenarios, not the decision about individual edges: (1) stimulus, fast and medium recall at least as high as that of the usual approach, vector autoregressions on signals binned onto common time grids (§ 7.1); (2) cross-scale recall above 0.5; (3) a false-positive rate of at most 0.05 in the clean scenario; (4) robustness values that rank faked edges below true ones (AUC at least 0.8; the criterion fixed in advance also included an analytic comparison, which will be reported together with the theory it relies on); (5) split-half Jaccard of at least 0.75.
| Share of replicates declaring | Grids (union) | Linear | Quadratic | Neural |
| Breathing heart rate reversed (HRRESP) | 1.00 | 0.04 | 0.04 | 0.04 |
| Indirect path as direct (SCEEG2) | 1.00 | 0.14 | 0.12 | 0.14 |
| Fast-to-slow edge through power (EEG2fNIRS, found) | 0.02 | 0.94 | 0.97 | 0.94 |
| Squared edge (SCfNIRS, nonlinear scenario, found) | 0.25 | 0.00 | 0.75 | 1.00 |
| Hidden arousal, strong (HRSC) | 0.88 | 1.00 | 0.88 | 1.00 |
| Hidden breathing, strong (HRfNIRS) | 1.00 | 1.00 | 1.00 | 1.00 |
| Volume conduction (EEG2EEG1) | 0.88 | 1.00 | 1.00 | 1.00 |
| Tempo trap (STIMHR) | 0.12 | 0.00 | 0.00 | 0.00 |
Table S6. Table S6: Share of replicates in which each method declares a trap edge (lower is better), or finds a hard true edge (rows marked “found”, higher is better); best values per row in bold.
Extended comparisons with established methods
Comparators
Common grids. Every signal is put on one grid by causal binning (bin means, the last sample when a bin is empty, the rate of the last completed heartbeat, beat counts), a vector autoregression (VAR) is fitted with a fixed order (15 lags on the 50-Hz grid, 8 on the 2-Hz grid), and each ordered pair is tested by the conditional Granger test ([42, 6]). We used a 50-Hz grid with lags up to 0.3 s, a 2-Hz grid with lags up to 4 s, and the union of their edges.
Established methods. We compared four established methods, each run on the same two common grids with the union of their edges, so that the comparison isolates the method from the gridding, on all eight replicates of each scenario. On the real recordings, the grid VAR, multiscale Granger causality and PCMCI tested each ordered pair once, as in the second version of the fairness experiment (Bonferroni over the pair’s grids and columns, one Benjamini–Hochberg procedure, power columns for the EEG nodes only); LPCMCI kept its own rule. We did not run VARX (Parra et al., [50]) as a separate method: without exogenous inputs it is a vector autoregression on a common grid, which the grid VAR covers. Its distinguishing feature, exogenous inputs such as stimulus features, is already how every method treats the benchmark’s stimulus, a source that is never a target, and has no counterpart in the real recordings, where no stimulus is modelled. Multiscale Granger causality (Faes et al., [26]), implemented from the paper: a VAR on the grid (order by BIC); for each scale , a causal finite-impulse-response (FIR) low-pass filter (order 6, Hamming window; Oppenheim and Schafer, [48]; cutoff cycles per sample) and downsampling by , written in state-space form; Granger causality at each scale from Riccati equations (Barnett and Seth, [7]). We used scales 1, 5 and 25 on the 50-Hz grid and 1, 2 and 4 on the 2-Hz grid. Our implementation reproduces the paper’s first example (Granger causality peaking at at 0.404, the reverse direction near zero). Significance follows the paper’s application, by surrogates: 10 surrogate data sets in which every series is circularly shifted by an independent random offset; the null values are pooled over pairs at each scale and fitted by a gamma distribution, whose tail gives the -values; a pair’s -value is the smallest over scales times the number of scales, and the Benjamini–Hochberg rule decides. When the Riccati solver failed (eigenvalues on the unit circle, with a strictly periodic stimulus), it was retried with a tiny regularization, and the scale was left out if it still failed; this happened only in a few scale computations of the tempo scenario. Neural Granger causality (Tank et al., [58]), run with the authors’ own code in its component-wise multilayer-perceptron form and with the settings of their demonstration: one network per target node with a hidden layer of 100 units, a hierarchical group penalty on the first-layer weights of each source node, and their proximal gradient training with early stopping (at most 50 000 iterations). If, in the network of , the first-layer weights of are not all zero after training, the edge is declared. The penalty was chosen once, among eight values from 0.0005 to 0.1, by the best F1 score (the harmonic mean of precision and recall) against the ground truth of one clean replicate, and then fixed, which favours the method; the chosen value, , was the largest tried, so a larger one might have done better. PCMCI (Runge et al., [53]) with partial-correlation tests (tigramite library; ): a pair’s -value is the smallest over lags times the number of lags, and the Benjamini–Hochberg rule decides. LPCMCI (Gerhardus and Runge, [28]), which allows hidden confounders, on the 2-Hz grid only because of its cost: LPCMCI marks each lagged link from to as ( drives ), (both are driven by a hidden confounder) or (one of the two, which LPCMCI cannot tell apart); a link marked or declares the edge , and a link marked is reported as hidden confounding, not as an edge. Its run time varied strongly with the data, so it ran with a 30-s limit and then with half the lags; it finished in 62 of 64 replicates, 18 of them with half the lags. To check that the limit did not distort its results, it was also run without a time limit on replicates 0–3, with a memory limit of 4 GB per data set, raised to 16 GB for those that exceeded it.
Fairness experiment and ablations
The established methods receive the signals’ bin means, whereas RMGG also passes fast signals to slower levels as their power. To separate the two, every method was also run with the same information: on the 2-Hz grid, each signal sampled at least ten times faster than the grid got a second column, the log variance of its native samples in each bin, and an edge from or to either column was counted as an edge of that node. RMGG’s rule (the 50-Hz grid was unchanged, since a 20-ms bin holds too few samples for power). This was done on all eight replicates per scenario; in this version breathing, sampled ten times faster than the 2-Hz grid, also received a power column. Because the edges of the two grids are joined, a pair has more than one chance to be declared. In a second version every method tested each ordered pair once: the pair’s -values over both grids and all its columns were combined by a Bonferroni correction, and one Benjamini–Hochberg procedure ran over the 36 pairs, with power columns for the EEG nodes only, as in RMGC. Neural Granger causality and LPCMCI give no -value per pair and kept their own rules. For neural Granger causality with power columns, the penalty followed a rule fixed in advance: starting at 0.1 and doubling, the smallest penalty giving an empty graph on the calibration replicate () was halved eight times and the value with the best F1 kept (). Three ablations of RMGC, on all eight replicates, removed one component each: the power channel; the rate matching, by linearly interpolating every slow sensor and the heart rate onto a 50-Hz grid before the analysis, as for a common grid (every signal is then predicted at the fast level, where power is not used); and the log-time windows, replaced by bin pooling (§ 1.1.2).
Benchmark
Table S4 and Figure S2 give recall and false-positive rates in each scenario, Table S5 averages them by edge class, and Table S6 shows how often each method fell into each trap. Figure 3 shows example graphs.
| Scenario | Grids (union) | Linear | Quadratic | Neural |
| Clean | 0.73 / 0.09 | 0.90 / 0.02 | 0.92 / 0.01 | 0.90 / 0.02 |
| Hidden arousal | 0.71 / 0.11 | 0.92 / 0.02 | 0.88 / 0.01 | 0.88 / 0.03 |
| Hidden arousal, strong | 0.83 / 0.14 | 1.00 / 0.06 | 1.00 / 0.05 | 1.00 / 0.07 |
| Hidden breathing | 0.75 / 0.08 | 1.00 / 0.02 | 1.00 / 0.02 | 1.00 / 0.02 |
| Hidden breathing, strong | 0.75 / 0.21 | 0.97 / 0.12 | 0.97 / 0.10 | 0.97 / 0.12 |
| Tempo near heart rate | 0.75 / 0.09 | 0.98 / 0.03 | 0.94 / 0.03 | 0.94 / 0.03 |
| Volume conduction | 0.75 / 0.17 | 0.90 / 0.12 | 0.90 / 0.12 | 0.88 / 0.11 |
| Nonlinear edge | 0.62 / 0.09 | 0.73 / 0.02 | 0.88 / 0.03 | 0.88 / 0.02 |
Table S4. Recall / false-positive rate per scenario (8 replicates of 10 min each); best values per row in bold.
| Method | Stimulus | Fast | Medium | Cross-scale | False-pos. rate | Split-half | Split-half ≥ 0.75 |
| Grids (union) | 1.00 | 1.00 | 0.72 | 0.50 | 0.12 | 0.74 | 1 of 8 |
| Linear | 1.00 | 1.00 | 0.80 | 0.93 | 0.05 | 0.80 | 6 of 8 |
| Quadratic | 1.00 | 1.00 | 0.77 | 0.97 | 0.05 | 0.73 | 2 of 8 |
| Neural | 1.00 | 1.00 | 0.75 | 0.97 | 0.05 | 0.76 | 4 of 8 |
Table S5. Recall by edge class (Section S1.1), false-positive rate and split-half reproducibility, averaged over the eight scenarios; best values per column in bold.
Figure S2. Figure S2: Recall (a) and false-positive rate (b) per scenario for the union of common grids and three RMGC variants.
Common grids. Neither grid alone found both the fast and the medium edges, and their union almost never found the edge from fast power to fNIRS (2% of replicates). The 2-Hz grid declared the indirect path SC EEG1 EEG2 as a direct edge SC EEG2 in every replicate, because the 20-ms relation between EEG1 and EEG2 falls inside one 0.5-s bin. The 50-Hz grid reversed RESP HR in every replicate in which breathing was observed: heart rate, a smoothed copy of past breathing, predicts the noisy and held breathing samples, the measurement-noise effect described by Nalatore et al. (2007).
RMGC. With window pooling, RMGC met criteria 1–3: stimulus and fast recall 1.00, medium recall 0.80 on average against 0.72 for the grids, cross-scale recall 0.93 against 0.50, and a false-positive rate of 0.02 in the clean scenario against 0.09. It avoided both sampling traps (the reversal in 4% and the indirect path in 14% of replicates). Its split-half reproducibility was 0.80 on average, at least 0.75 in 6 of 8 scenarios. With bin pooling it also found the cross-scale edges but had lower medium recall (0.68; Table 3).
Nonlinear variants. In the nonlinear-edge scenario the squared edge was found by RMGC-NN in every replicate and by the quadratic variant in 75%, never by RMGC, and in 25% by the union of grids (slow drift gives the square a partly linear component over 10 min). In the other scenarios RMGC-NN had about the linear one’s false-positive rate, with lower recall in 3 of 7 scenarios (0.88 against 0.92, 0.94 against 0.98, 0.88 against 0.90) and lower medium recall (0.75 against 0.80), the cost of the Bonferroni factor in its combined test. The quadratic variant was the least reproducible (split-half 0.73, at least 0.75 in 2 of 8 scenarios), the neural one in between (0.76, 4 of 8).
What no method solved. Strong hidden drivers were declared by the grids and all RMGC variants (HR SC in 88–100% of replicates; HR fNIRS under strong hidden breathing in all), and volume conduction made them declare EEG2 EEG1 (in 88–100% of replicates; time reversal removes it, § 9.3). The established methods declared these edges less often (HR SC under strong arousal in 12.5% of replicates for multiscale Granger causality, 25% for PCMCI, 62.5% for LPCMCI and 75% for neural Granger causality; EEG2 EEG1 never for multiscale Granger causality, neural Granger causality and LPCMCI), partly because they declare fewer edges, so Table S6 reads best next to recall. The tempo trap rarely caught any method (at most 12%): Granger tests condition on the heart’s own rhythm.
Established methods
On the benchmark, Table S7 gives the established methods next to the three RMGC variants, on the same replicates. The RMGC variants had the highest recall in every scenario (0.92–0.93 on average, against 0.43–0.77) and the highest AUC (0.98, against 0.68–0.88), with false-positive rates as low as the most cautious established methods (0.05; Table S8 gives the intervals). Multiscale Granger causality had the lowest false-positive rate among the established methods (0.05), equal to the RMGC variants, but found far fewer true edges (recall 0.65 against 0.92). Neural Granger causality had the highest recall among the established methods (0.77) but more than twice the RMGC variants’ false-positive rate (0.13), although its penalty was chosen with the ground truth. No established method found the fast-to-slow edge carried by EEG power, because they receive each signal’s bin means but not its power: their cross-scale recall stayed at 0.48–0.51, about one of the two cross-scale edges. Given the same power features, they find it (§ 7.5). LPCMCI’s marks of hidden confounding fell mostly on the fast EEG pair and the power edge: EEG1 EEG2 (12 of 64 replicates, a true edge), EEG2 fNIRS (10, true) and EEG2 EEG1 (10), relations that a linear test on a common grid cannot represent.
| Method | Recall | False-positive rate | AUC |
| Grids (union) | 0.74 [0.72, 0.75] | 0.12 [0.12, 0.14] | 0.88 [0.87, 0.89] |
| Multiscale GC | 0.65 [0.64, 0.67] | 0.05 [0.04, 0.05] | 0.86 [0.85, 0.87] |
| Neural GC | 0.77 [0.76, 0.78] | 0.13 [0.12, 0.14] | 0.84 [0.84, 0.85] |
| PCMCI | 0.69 [0.67, 0.71] | 0.10 [0.09, 0.11] | 0.86 [0.85, 0.88] |
| LPCMCI | 0.43 [0.40, 0.46] | 0.05 [0.04, 0.06] | 0.68 [0.66, 0.70] |
| RMGC | 0.92 [0.90, 0.94] | 0.05 [0.04, 0.06] | 0.98 [0.97, 0.98] |
| RMGC, quadratic | 0.93 [0.92, 0.95] | 0.05 [0.04, 0.05] | 0.98 [0.98, 0.99] |
| RMGC-NN | 0.93 [0.91, 0.95] | 0.05 [0.04, 0.06] | 0.98 [0.97, 0.99] |
Table S8. Means over all scenarios with 95% bootstrap intervals (replicates resampled within scenarios).
Fairness and ablations
On the benchmark, given the same power information (Table S9; 64 replicates, eight per scenario), a VAR on the common grids found the fast-to-slow edge in almost every replicate and matched the RMGC variants’ recall (0.91 against 0.92): the RMGC variants’ cross-scale advantage came from the power features, not from the levels. What remained was the advantage of not resampling. At the same recall the grid VAR kept about 2.5 times the RMGC variants’ false-positive rate (0.13 against 0.05) and declared the reversed breathing edge and the indirect edge SC EEG2 in every replicate, where RMGC declared them in 4% and 14% (2% outside the volume-conduction scenario, where mixing of EEG1 and EEG2 makes SC EEG2 partly real). Power also helped multiscale Granger causality and PCMCI (AUC 0.94 and 0.92), but neither avoided both traps.
| Method | Recall | False-pos. rate | AUC | Cross-scale | EEG2fNIRS found | Reversed HRRESP | Indirect SCEEG2 |
| Grids (union) | 0.74 | 0.12 | 0.88 | 0.50 | 0.02 | 1.00 | 1.00 |
| Grids (union) + power | 0.91 | 0.13 | 0.96 | 0.97 | 1.00 | 1.00 | 1.00 |
| Multiscale GC | 0.65 | 0.05 | 0.86 | 0.48 | 0.00 | 0.00 | 1.00 |
| Multiscale GC + power | 0.70 | 0.05 | 0.94 | 0.61 | 0.27 | 0.00 | 0.98 |
| PCMCI | 0.69 | 0.10 | 0.86 | 0.51 | 0.03 | 0.10 | 0.84 |
| PCMCI + power | 0.76 | 0.10 | 0.92 | 0.75 | 0.53 | 0.10 | 0.80 |
| LPCMCI | 0.43 | 0.05 | 0.68 | 0.51 | 0.06 | 0.02 | 0.30 |
| LPCMCI + power | 0.33 | 0.05 | 0.61 | 0.41 | 0.31 | 0.00 | 0.16 |
| Neural GC | 0.77 | 0.13 | 0.84 | 0.51 | 0.02 | 0.12 | 1.00 |
| Neural GC + power | 0.92 | 0.18 | 0.90 | 0.92 | 0.84 | 0.27 | 1.00 |
| RMGC | 0.92 | 0.05 | 0.98 | 0.93 | 0.94 | 0.04 | 0.14 |
| RMGC, quadratic | 0.93 | 0.05 | 0.98 | 0.97 | 0.97 | 0.04 | 0.12 |
| RMGC-NN | 0.93 | 0.05 | 0.98 | 0.97 | 0.94 | 0.04 | 0.14 |
Table S9. Fairness experiment: each established method with and without the power columns, against the RMGC variants (64 replicates, eight per scenario). The last three columns give the share of replicates declaring the edge.
Neural Granger causality with power matched the RMGC variants’ recall exactly (0.92) but had 3.5 times their false-positive rate (0.18), and declared the indirect edge in every replicate and the reversed one in 27%. LPCMCI with power columns did not finish within its time limit in 31 of 64 replicates and needed half its lags in 25 more, so its row is not a fair test of the method itself. Run without a time limit on the same data (replicates 0–3), LPCMCI with power columns finished only 9 of 32 data sets: 22 exceeded 4 GB of memory and 1 crashed. Without power columns it finished 29 of 32 (the other three exceeded 16 GB after about 3.5 hours each) with the same results as under the time limit (recall 0.44 against 0.45, false-positive rate 0.07 against 0.06), so the limit did not distort its results, and with power columns it is not computationally feasible.
With one test per pair for every grid method (Table 2), the grid VAR with EEG power kept the RMGC variants’ recall (0.92) at a false-positive rate of 0.12, 2.4 times RMGC’s 0.05, and still declared the reversed and the indirect edge in every replicate. Multiscale Granger causality with power had a slightly lower false-positive rate than the RMGC variants (0.045 against 0.051) but found far fewer true edges (recall 0.68) and also declared the indirect edge in every replicate; PCMCI with power reached recall 0.78 at 0.10. The RMGC variants’ advantage therefore does not come from the union of the grids.
The ablations (Table 3, 64 replicates) remove one component at a time from RMGC, instead of adding power to the established methods, and confirm this attribution. Without its power channel RMGC found the fast-to-slow edge in 2% of replicates instead of 94% (cross-scale recall 0.49 against 0.93). With every slow sensor and the heart rate interpolated onto a 50-Hz grid, the reversed breathing edge appeared in every replicate, the false-positive rate rose from 0.05 to 0.12 and medium recall fell from 0.80 to 0.60; this variant also loses the power channel. Replacing the log-time windows by bins lowered medium recall from 0.80 to 0.68. Every RMGC variant avoided the indirect edge (14–16%), the interpolated one included, so its avoidance comes from the long causal history of the windows rather than from rate matching.
Sensitivity and calibration
Null scenario and sensitivity: methods
Null scenario. To check calibration, the clean scenario was simulated with every edge and the stimulus effect removed, so that every signal keeps its own dynamics and sensors and any declared edge is false (8 replicates).
Sensitivity. The lag spans of all levels and the window horizon were halved and doubled, and RMGC-NN was also run with fixed network sizes of 4, 8, 16 and 32 units, with values set in advance.
Sensor rates that do not match the levels (EEG at 100 Hz, fNIRS at 10 Hz, skin conductance at 1 Hz) and two other level spacings (100/10/1 Hz and 25/2.5/0.25 Hz, with the same time spans of the own past) were also run. Two further scenarios, outside the eight, put a hidden driver outside the attack’s class: an Ornstein–Uhlenbeck drift with a 60-s time constant driving heart rate and skin conductance, and a 0.25-Hz oscillation that modulates EEG2’s amplitude and drives heart rate, faking EEG2 HR through EEG2’s power (8 replicates each).
Sensitivity
On the benchmark, halving or doubling the lags of every level together with the window horizon (8/10/4 bins and 8 s, or 30/40/16 bins and 32 s, instead of 15/20/8 bins and 16 s) left RMGC essentially unchanged over the 64 replicates: recall 0.93 and 0.91 (0.92 with the chosen spans), false-positive rate 0.05 in all three cases, AUC 0.98 and 0.97 (0.98), medium-scale recall 0.79 and 0.76 (0.80). (Table S11). With a fixed network size, the power to detect the squared edge depended strongly on it: 50%, 88%, 38% and 25% of replicates for 4, 8, 16 and 32 units, while the linear edges were unaffected (Table S12). Chosen by inner validation, the size was 4 units in 68% of the fits, 8 in 7%, 16 in 8% and 32 in 18%, and the squared edge was found in every replicate. With sensor rates that do not match the levels, the RMGC variants performed as before (recall 0.92–0.93, false-positive rate 0.04; Table S10), and the grid VAR kept the reversed edge in every replicate. Finer levels (100/10/1 Hz) kept recall (0.89) and the false-positive rate (0.05) but lowered medium recall (0.64); coarser levels (25/2.5/0.25 Hz) nearly doubled the false-positive rate (0.09) and brought the reversed breathing edge back in every replicate: with 0.4-s bins the heart-rate target is averaged over about the 0.5-s breathing delay, which recreates the common grid’s error. The bins must be short compared with the coupling delays.
| Variant | Recall | False-pos. rate | Medium recall | Reversed HRRESP |
| Mismatched rates: RMGC | 0.92 | 0.04 | 0.78 | 4% |
| Mismatched rates: RMGC, quadratic | 0.93 | 0.04 | 0.77 | 2% |
| Mismatched rates: RMGC-NN | 0.92 | 0.04 | 0.75 | 2% |
| Mismatched rates: Grid VAR, one test per pair | 0.73 | 0.12 | 0.70 | 100% |
| Mismatched rates: Grid VAR + power, one test per pair | 0.91 | 0.12 | 0.71 | 100% |
| RMGC, levels 100/10/1 Hz | 0.89 | 0.05 | 0.64 | 2% |
| RMGC, levels 25/2.5/0.25 Hz | 0.91 | 0.09 | 0.73 | 100% |
| RMGC, levels 50/5/0.5 Hz (chosen) | 0.92 | 0.05 | 0.80 | 4% |
Table S10. Sensor rates that do not match the levels (EEG 100 Hz, fNIRS 10 Hz, skin conductance 1 Hz), and other level spacings of RMGC (64 replicates).
| Lag spans | Recall | False-positive rate | AUC | Medium recall | Cross-scale recall |
| 1/2 (8/10/4 bins, 8 s) | 0.93 | 0.05 | 0.98 | 0.79 | 0.94 |
| Chosen (15/20/8 bins, 16 s) | 0.92 | 0.05 | 0.98 | 0.80 | 0.93 |
| 2 (30/40/16 bins, 32 s) | 0.91 | 0.05 | 0.97 | 0.76 | 0.93 |
Table S11. Sensitivity to the lag spans (RMGC, 64 replicates).
| Hidden units | Squared edge found | Nonlinear: recall / FPR | Clean: recall / FPR | Strong arousal: recall / FPR |
| 4 | 50% | 0.79 / 0.03 | 0.88 / 0.02 | 1.00 / 0.07 |
| 8 | 88% | 0.86 / 0.01 | 0.90 / 0.02 | 1.00 / 0.05 |
| 16 | 38% | 0.77 / 0.03 | 0.88 / 0.02 | 1.00 / 0.07 |
| 32 | 25% | 0.75 / 0.03 | 0.88 / 0.02 | 1.00 / 0.07 |
| chosen by inner validation | 100% | 0.88 / 0.02 | 0.90 / 0.02 | 1.00 / 0.07 |
Table S12. RMGC-NN with fixed network sizes and with the size chosen by inner validation (8 replicates per scenario).
Null scenario
In the benchmark’s null scenario, with no edges at all (Table S13), all three RMGC variants declared a single false edge in 1 of 8 replicates (false-positive rate 0.003), in line with a 5% false-discovery rate under the global null; the grid VAR, multiscale Granger causality and PCMCI behaved similarly. LPPCMCI declared false edges in 7 of 8 replicates (false-positive rate 0.08), because its decision applies each test at 5% without a correction for multiplicity. Neural Granger causality declared false edges in 4 of 8 replicates (false-positive rate 0.017): it declares an edge wherever a group of weights is not zero, a rule that, unlike the Benjamini–Hochberg procedure, sets no limit on the expected share of false edges.
| Method | False edges per replicate | False-positive rate | Replicates with a false edge |
| RMGC | 0.12 | 0.003 | 1 of 8 |
| RMGC, quadratic | 0.12 | 0.003 | 1 of 8 |
| RMGC-NN | 0.12 | 0.003 | 1 of 8 |
| Grids (union) | 0.00 | 0.000 | 0 of 8 |
| Grids (union) + power | 0.12 | 0.003 | 1 of 8 |
| Multiscale GC | 0.12 | 0.003 | 1 of 8 |
| Multiscale GC + power | 0.12 | 0.003 | 1 of 8 |
| PCMCI | 0.12 | 0.003 | 1 of 8 |
| PCMCI + power | 0.25 | 0.007 | 1 of 8 |
| LPCMCI | 2.75 | 0.076 | 7 of 8 |
| LPCMCI + power | 2.50 | 0.069 | 7 of 8 |
| Neural GC | 0.62 | 0.017 | 4 of 8 |
Table S13. Null scenario (no edges; 8 replicates, 36 candidate pairs each).
Nonlinear extension and time reversal
Nonlinear variants
RMGC finds an edge only if part of the source’s influence is linear in its window values. Physiological couplings can also be nonlinear: an effect may grow with the square of a signal, saturate, or depend on its amplitude in ways the power channel does not capture. We therefore propose two extensions that keep RMGC’s levels, windows and decision rule. The quadratic variant adds squared terms to each source’s block and keeps the test. RMGC-NN keeps every test of RMGC and adds, for each source, a separate test of whether a small network on the source’s past improves the prediction.
Both reduce each source’s windows to three summaries per value type (mean or power): the averages over the near, middle and far thirds of its windows. With windows and values ,
which for a medium-level target covers 0–0.6 s, 0.6–1.4 s and 1.4–12.8 s before the target bin (Table S3). Nonlinear terms on all windows would fit noise on many nearly collinear inputs; summaries avoid this.
Quadratic variant. Each summary is standardized (, zero mean and unit variance over the recording) and is added to the source’s block, three columns per value type. The block stays linear in its parameters and is tested by the same test.
RMGC-NN. Its network test works in two stages (Figure S3). In a first stage RMGC’s least-squares model predicts the target, leaving residuals . In a second stage a network with one hidden layer of units predicts these residuals from the source’s standardized summaries (three or six inputs):

Figure S3. RMGC-NN for one target and one source : should the edge be declared? RMGC’s model of is fitted first; a small network on ’s summaries then predicts its residuals, and the network’s out-of-sample gain is tested. The edge is declared on linear or nonlinear evidence.
It is trained on the mean squared error plus times the squared weights, with full-batch Adam (Kingma and Ba, [39]) (learning rate 0.01, at most 800 steps, , , at the start) and early stopping on the last 20% of the training data (checked every 10 steps, stopping after 100 steps without improvement). The number of hidden units is chosen within each training half by inner validation: networks with 4, 8, 16 and 32 units are trained on the same 80% and the one with the lowest error on the remaining 20% is kept, so the held-out half never influences the choice. Its gain is measured out of sample by two-fold cross-fitting (Chernozhukov et al., [17]): fit on the first half of the recording and predict the second, then swap. With the difference between the squared out-of-sample errors without and with the network, a one-sided Diebold–Mariano test (Diebold and Mariano, [20]) uses
where is the mean of and the hats mark estimates: is the sample autocovariance of at lag , and the resulting Newey–West estimate of its variance, which accounts for autocorrelation (Newey and West, [47]). DM can take any real value: it is positive when the network lowers the out-of-sample error and approximately standard normal when the network does not help, so the one-sided -value is . An edge is supported by linear evidence (the test) or by nonlinear evidence (the DM test); the two -values are combined as before the false-discovery-rate rule. Fast-level targets use every fourth bin to keep training cheap. The two-stage design keeps the network small and its inputs few, so that it extends the linear model without overfitting it.
Nonlinear edges. For an edge supported only by RMGC-NN’s nonlinear evidence, the attack removes ’s linear and network contributions, adds drivers from a class of six (an Ornstein–Uhlenbeck driver and the two oscillators acting linearly; two drivers linear in and squared in , which can fake a nonlinear edge; one squared in both; delay difference 1 s), refits the networks and bisects on the cross-fitted gain.
Time reversal: methods
Time reversal. A directed influence reverses when the data are reversed in time, whereas dependence produced by mixing or other time-symmetric effects does not [35, 63]. For a pair declared in both directions, the statistic is the net flow on the original data minus the net flow on the time-reversed data, , with the edge size and the same on the recording mirrored in time (every stream at its own rate). is computed in five equal blocks, and a direction is kept if its mean is significantly positive (one-sided test, 5%). This is the difference-based variant of time-reversed Granger causality [63], whose validity is proven for unidirectional coupling between two linear autoregressive variables; with several signals and possibly bidirectional coupling it is a heuristic check. Edges declared in one direction only are not tested, and stimulus edges are exempt.
Neural extension on the real data. On the same segments of all three data sets, RMGC-NN was also run with and without breathing. Edges it declared that RMGC did not (added edges) received a robustness value from the nonlinear attack and their breathing multiple.
Time reversal
On the benchmark, applied to the pairs that RMGC declared in both directions (Table S15), time reversal removed the volume-conduction edge EEG2 EEG1 in every replicate (100% to 0%), lowered the share of replicates with the edge faked by strong hidden breathing from 100% to 75% and the false-positive rate from 0.05 to 0.04, at essentially no cost in recall (0.92 to 0.92). Applied to every edge, it removed nearly all false edges, including those faked by arousal, but lost 29% of the true ones (recall from 0.92 to 0.66): five blocks give too little power for slow edges.
| Variant | Recall | False-positive rate | Medium recall | Cross-scale recall | Volume EEG2→EEG1 | Hidden breathing | HR↔fNIRS | Arousal HR→SC |
| RMGC | 0.92 | 0.05 | 0.80 | 0.93 | 100% | 100% | 35% | |
| + time reversal, pairs declared both ways | 0.92 | 0.04 | 0.79 | 0.92 | 0% | 75% | 35% | |
| + time reversal, all edges | 0.66 | 0.01 | 0.31 | 0.54 | 0% | 12% | 0% |
Table S15. Time reversal on RMGC’s edges (64 replicates).
The neural extension on the real recordings
In sleep, RMGC-NN added edges to RMGC’s in 9% of the 115 segments; with breathing hidden it added 6 edges, 3 of them breathing-sensitive. In BBBD it added edges in 70% of the 518 recordings (1.4 per recording), mostly from the EOG to heart rate and breathing and between pupil and breathing; 64% of those it added with breathing hidden were breathing-sensitive, against 4% of RMGC’s edges, and they were fragile (median RV 0.03, for 73%); it missed linear edges in 75% of the recordings. In MultiPhysio-HRC it added edges in 94% of the 557 segments, 4.1 per segment, and 55% of those it added with breathing hidden were breathing-sensitive, against 6% of RMGC’s edges (both with the threshold recomputed). The added edges were fragile: their median RV was 0.03 and their median breathing multiple 0.19, with for 77% of them (in sleep, for 5 of the 6). The robustness values did not, however, separate the breathing-sensitive added edges from the stable ones (AUC 0.50). The positive control was unchanged (breathing heart rate in 82% of the guided-breathing segments for both variants; in sleep 91% against 93%). Because its combined test gives each of its two tests half the threshold, RMGC-NN also missed some of RMGC’s edges, in 33% of the sleep and 79% of the awake segments.
Discussion of the nonlinear extension
The neural extension finds nonlinear edges, at a cost. RMGC-NN keeps every linear test, but its combined test gives each of its two tests half the threshold, so it finds slightly fewer linear edges (medium recall 0.75 against 0.80); in exchange it alone among the RMGC variants found the squared edge in every replicate, with the network size chosen by inner validation. Two design choices made this possible: a small network on a few summaries per source, fitted to the residuals of the linear model, and tests that use all data through cross-fitting. Networks fitted to every window of every source would multiply the parameters; with the small datasets of physiological studies, a neural model works best as an extension of a well-specified linear model rather than a replacement.
On real data, what the network adds is largely breathing. Breathing affects heart rate, EEG amplitude and skin conductance, not always linearly. With breathing hidden, signals that depend on it share residual dependence that is partly nonlinear: RMGC cannot see it, the network can. In the awake recordings about half of the edges the network added were of this kind. Their robustness values were low (median 0.03): the corrected search flags the added edges as fragile, whether they come from breathing or not, but cannot tell which do. The power channel already brings the most important nonlinearity, the dependence on a fast signal’s power, into RMGC. We therefore recommend RMGC as the default and RMGC-NN when nonlinear effects are expected, with the edges it adds checked against measured candidate drivers.
Detailed real-data analyses
Prevalence across participants. An edge counts as present in a participant if it is declared in more than half of that participant’s segments in a task group. Following the logic of prevalence inference ([1]), we ask whether an edge is present in most people, rather than whether it is present on average. Each participant contributes a yes or a no. If at most half of the population has the edge, a participant shows it with probability at most : the half who have it, plus false positives, at a rate of at most , among the others. A one-sided binomial test against this bound, with the Benjamini–Hochberg rule across edges, asks whether the edge is present in most participants.
Overnight sleep recordings
The six recordings gave 115 analysed segments (10 skipped, 9 of them in wake, mostly for implausible heartbeat intervals) and 438 edges in the hidden-breathing runs (Table S19). Of the 44 edges that appeared only with breathing hidden, 6 did so only because the threshold moved (their -values would not pass the threshold of the run with breathing); the other 38 are the breathing-sensitive edges. Hiding the placebo made 42 edges appear, but only 5 at a fixed threshold (Table S16), so at a fixed threshold the breathing-sensitive edges were about eight times the placebo’s base rate. The breathing multiple was at most 1 for 84% of the breathing-sensitive edges and 23% of the stable ones; ranked by the breathing multiple, the two groups separated with AUC 0.88 [0.84, 0.92] (recordings resampled; RV alone 0.83, size 0.69). Per recording, 33–100% of the breathing-sensitive edges had and the AUC was 0.81–0.95. By sleep stage, for 88%, 80% and 80% of the breathing-sensitive edges in light NREM (17 edges), deep NREM (15) and REM (5), and for the single one in wake, against 17–41% of the stable edges. Of the 38 breathing-sensitive edges, 37 were brain–heart edges (EEG heart rate) and one linked heart rate and SpO₂. Breathing explained a median of 9.8% of heart rate but only 0.4% of the EEG bins, so small multiples came from heart rate: for 7% of the 242 stable edges other than brain–heart ones and 49% of the 152 stable brain–heart edges. Within brain–heart edges, the breathing multiple separated breathing-sensitive from stable edges with AUC 0.75 [0.69, 0.82], about as well as edge size (0.70). Breathing-sensitive brain–heart edges needed a median of 0.42 times breathing’s share (interquartile range 0.23–0.73), none more than twice it; stable brain–heart edges needed 1.01 (0.58–1.87): about half could be produced by a hidden driver as strong as breathing, and 23% needed more than twice its strength (Figure 4c).
| Data | Segments | Breathing hidden | Breathing hidden | Placebo hidden | Placebo hidden |
| Recomputed | Fixed threshold | Recomputed | Fixed threshold | ||
| Sleep (CAP) | 115 | 44 | 38 | 42 | 5 |
| Awake (BBBD) | 518 | 481 | 369 | 373 | 148 |
| Stress test (MultiPhysio-HRC) | 557 | 736 | 670 | 675 | 424 |
Table S16. Hide-breathing test and its placebo control: edges that appear when breathing, or a placebo (a copy of breathing shifted by half its stream’s span), is hidden; with the Benjamini–Hochberg threshold recomputed, and at the fixed threshold of the run with the hidden node.
| Rec. | Hours | EEG | Breathing | Segments | Skipped | Edges | Sensitive | (sens./stable) | AUC |
| n1 | 9.6 | F4-C4 / C4-P4 | TORACE | 18 | 0 | 77 | 11 | 82% / 29% | 0.81 |
| n4 | 9.9 | F4-C4 / C4-P4 | toracico | 19 | 4 | 62 | 7 | 100% / 33% | 0.89 |
| n6 | 8.8 | C3-A2 / O2-A1 | THE | 18 | 2 | 68 | 3 | 33% / 11% | 0.84 |
| n7 | 8.2 | C3-A2 / O2-A1 | THE | 19 | 1 | 64 | 3 | 100% / 18% | 0.95 |
| n8 | 8.3 | C3-A2 / C4-P4 | flow | 20 | 1 | 76 | 9 | 78% / 22% | 0.86 |
| n9 | 8.9 | C3-A2 / O2-A1 | THE | 21 | 2 | 85 | 5 | 100% / 26% | 0.95 |
Table S19. Hide-breathing test on the CAP recordings: segments, edges of the hidden-breathing run, breathing-sensitive edges, share with and AUC of the breathing multiple.
The brain–heart edges did not come from the method itself. Pairing the EEG of one recording with the breathing, heart rate and oxygen saturation of another, in segments of the same sleep stage, gave 0.14 brain–heart edges per segment (4% of the possible ones), against 1.37 (34%) in the real recordings (Table S17).
| Data | Brain–heart per segment | Brain–other body per segment |
| Sleep (CAP), real | 1.37 (34%) | 1.68 (21%) |
| Sleep, EEG of another recording | 0.14 (4%) | 0.14 (2%) |
| Awake (BBBD), real | 0.53 (7%) | 4.80 (30%) |
| BBBD, EEG of another participant | 0.17 (2%) | 0.47 (3%) |
| BBBD, body signals shifted circularly | 0.19 (2%) | 0.35 (2%) |
| Stress test (MultiPhysio-HRC), real | 2.26 (28%) | 10.13 (42%) |
| MultiPhysio-HRC, EEG of another participant | 1.36 (17%) | 3.96 (16%) |
| MultiPhysio-HRC, body signals shifted circularly | 0.99 (12%) | 2.94 (12%) |
Table S17. Brain–body edges per segment (in brackets, the share of the possible edges) in the real recordings and in surrogates without coupling: the EEG of another recording or participant, or the participant’s own body signals shifted circularly by half the segment.
The two EEG derivations were declared to drive each other in every segment of every recording, including those whose derivations share no electrode. Time reversal resolved them: in 59 of the 115 segments neither direction was kept, consistent with mixing; where one was kept it was almost always the anterior to posterior one (EEG1 EEG2 in 49 segments, the reverse in 7), and this direction rose with sleep depth (kept in 11% of wake, 19% of REM, 46% of light NREM and 71% of deep NREM segments), following the prevalence of sleep slow oscillations, which travel mostly from front to back ([44]). Of the 64 brain–heart directions declared in both directions, 1 survived. For breathing and heart rate, time reversal kept HR RESP more often (8) than the physiologically expected RESP HR (1); breathing and heart rate are plausibly coupled in both directions (breathing modulates heart rate, and heartbeats influence the timing of breaths), a case for which the validity of time reversal is not established ([63]), so its directional verdicts for this pair should not be trusted.
On a subset fixed in advance, one segment per sleep stage of each recording (22 segments; Table S18), the established methods found breathing heart rate about as often as RMG C (82–95% against 91%), produced comparable numbers of edges that appeared with breathing hidden (all brain–heart), and all declared the EEG derivations driving each other in every segment. LPCMCI did not finish in most runs. In light NREM, deep NREM and REM, breathing heart rate and both EEG directions were present in all six recordings, and no brain–heart edge was; wake, with four recordings, was the exception (breathing heart rate in three of them, EEG1 HR in all four).
| Method | Breathing → heart rate | Breathing-sensitive edges per segment | EEG1 ↔ EEG2 | Edges per segment |
| Grid VAR | 95% | 0.50 | 100% | 7.4 |
| Multiscale GC | 82% | 0.45 | 100% | 6.5 |
| PCMCI | 86% | 0.45 | 100% | 6.2 |
| LPCMCI1 | 27% | 0.73 | 18% | 1.9 |
| RMGC | 91% | 0.59 | 100% | 6.7 |
Table S18. Established methods and RMGC on the same 22 sleep segments (one per stage and recording).
########## Awake recordings: BBBD
Of 535 recordings from 91 participants, 518 were analysed (89 participants; 244 in experiment 4, 274 in experiment 5); 14 were skipped for missing or flat pupil data and 3 for EEG artefacts. The surrogates showed a low background rate: with the body signals shifted circularly against EEG and EOG, 2% of the possible brain–heart and brain–other body edges were declared, and 2–3% with another participant’s body signals for the same video (Table S17). These recordings are as short as MultiPhysio-HRC’s, so short segments alone do not raise the background rate. The positive control held in 99% of recordings. Hiding breathing made 481 edges appear, 369 at a fixed threshold, against 148 for the placebo (Table S16).
Brain–heart edges were rare and fragile: 7% of the possible ones were declared, about three times the surrogate rate, and the breathing multiple was at most 1 for 94% of the stable and 98% of the breathing-sensitive ones; it separated the two groups with AUC 0.63, about as well as edge size (0.68; Table S20). Edges between the EEG and the pupil were frequent (30% of the possible brain–other body edges, almost all pupil ↔ EEG in both directions) and less fragile (median breathing multiple 1.15 when stable), and for them the breathing multiple separated breathing-sensitive from stable edges better than edge size (0.62 against 0.43). They persisted with the EOG in the model and were rare in both surrogates (3.11 pupil–EEG edges per recording, against 0.17 with the body signals shifted circularly and 0.26 with another participant’s), so they were not produced by the shared video or by eye movements that the EOG captures; but time reversal kept a direction for only 51 of 804 pupil–EEG directions declared both ways, so this dependence is mostly undirected. The EOG drove the EEG regions in nearly every recording (9.6 EOG edges per recording). Time reversal kept breathing → heart rate in 15 recordings and the reverse in 3. At group level, the edges present in most participants were, in both experiments, those among the EEG regions and the EOG, and breathing → heart rate; no brain–heart and no pupil–EEG edge was present in most participants.
| Edge type | Stable / sensitive | (stable / sensitive) | AUC: / size | Breathing multiple (stable / sensitive) |
| Brain–heart | 179 / 123 | 94% / 98% | 0.63 / 0.68 | 0.37 / 0.30 |
| Brain–other body | 1563 / 74 | 43% / 59% | 0.62 / 0.43 | 1.15 / 0.79 |
| Body–body | 128 / 95 | 99% / 100% | 0.48 / 0.61 | 0.17 / 0.18 |
Table S20. BBBD: stable and breathing-sensitive edges of the hidden-breathing runs by edge type, the share with , AUC separating them (breathing multiple, edge size) and median breathing multiples.
On the 88 recordings of the subset (Table S21), every method except LPCMCI found breathing → heart rate (93–98%, RMGC 99%); RMGC declared about as many brain–heart edges as the grid VAR and PCMCI (0.49 against 0.51 and 0.40 per recording), about half of the grid VAR’s pupil ↔ EEG edges and less than half of PCMCI’s (1.57 against 2.86 and 3.23). LPCMCI declared almost no edges within its time limit.
| Method | Segments | Breathing heart rate | Edges per segment | Brain–heart | Pupil EEG |
| Grid VAR | 88 | 98% | 27.8 | 0.51 | 2.86 |
| Multiscale GC | 88 | 98% | 23.1 | 0.10 | 1.78 |
| PCMCI | 88 | 93% | 26.9 | 0.40 | 3.23 |
| LPCMCI | 88 | 5% | 0.4 | 0.01 | 0.05 |
| RMGC | 88 | 99% | 26.2 | 0.49 | 1.57 |
Table S21. BBBD: the established methods and RMGC on each participant’s first recording of session 1 (a subset fixed in advance). The grid VAR, multiscale GC and PCMCI test each pair once.
########## Stress test: MultiPhysio-HRC
Of 779 segments from 52 participants, 557 were analysed (51 participants); the others were skipped for heartbeat problems (93 segments), EEG artefacts (87 in the frontal regions alone) and flat skin-conductance or breathing signals (28), among others (Table S23). The positive control held: breathing heart rate was declared in 82% of guided-breathing segments and 64–70% of rest and cognitive segments, less often during movement (virtual reality 37%, manual tasks 47%, cobot tasks 57%). Breathing’s share in heart rate followed the tasks: a median of 0.42 during guided breathing, 0.09–0.11 at rest and in the cognitive and virtual-reality tasks, and 0.04 in the manual and cobot tasks. Breathing also reached the EEG regions (medians 3–4% of their bins), skin conductance and the trapezius (4% each).
| Task group | Segments | Breathing heart rate | Breathing share in heart rate | Brain–body edges (stable / sensitive) | (stable / sensitive) |
| Rest | 96 of 130 | 64% | 0.10 | 851 / 138 | 84% / 94% |
| Guided breathing | 28 of 47 | 82% | 0.42 | 319 / 58 | 87% / 97% |
| Cognitive | 118 of 174 | 70% | 0.11 | 1491 / 192 | 86% / 97% |
| Virtual reality | 19 of 50 | 37% | 0.09 | 182 / 20 | 68% / 70% |
| Manual task | 158 of 196 | 47% | 0.04 | 1105 / 142 | 64% / 80% |
| Cobot task | 138 of 182 | 57% | 0.04 | 923 / 115 | 63% / 71% |
Table S23. Awake recordings by task group: analysed segments, the positive control (breathing heart rate declared with breathing), breathing’s share in heart rate (median), brain–body edges of the hidden-breathing runs and the share with .
The hidden-breathing runs had 12 250 edges; 736 appeared only with breathing hidden, 670 of them at a fixed threshold. Hiding the placebo made 675 edges appear, 424 at a fixed threshold (Table S16): in these recordings the base rate is almost two thirds of the breathing-sensitive count, so most of their breathing-sensitive edges cannot be attributed to breathing. The four EEG regions drove each other in 97% of the segments (6643 stable EEG–EEG edges). Among brain–body and body–body edges (Table S24), for 83–92% of the breathing-sensitive edges but also for 70–79% of the stable ones; the breathing multiple separated the two groups with AUC 0.58–0.66, about the same as edge size (0.54–0.61). Within brain–heart edges the AUC was 0.65 [0.59, 0.70] (participants resampled). Brain–heart edges needed a median of 0.38 times breathing’s share when stable and 0.17 when breathing-sensitive, against 1.01 and 0.42 in sleep. Robustness values rose with edge size (rank correlation 0.30) and were similar across segment lengths (medians 0.04–0.06). The drivers that set the RV were mostly oscillators, acting linearly or through their square.
| Edge type | Stable / sensitive | (stable / sensitive) | AUC: / RV / size | Breathing multiple (stable / sensitive) |
| EEG–EEG | 6643 / 5 | 56% / 100% | 0.95 / 0.89 / 0.95 | 0.66 / 0.00 |
| Brain–heart | 1038 / 171 | 79% / 92% | 0.65 / 0.60 / 0.54 | 0.38 / 0.17 |
| Brain–other body | 2956 / 340 | 76% / 83% | 0.58 / 0.59 / 0.57 | 0.36 / 0.23 |
| Body–body | 877 / 154 | 70% / 91% | 0.66 / 0.62 / 0.61 | 0.54 / 0.29 |
Table S24. Awake recordings by edge type: stable and breathing-sensitive edges of the hidden-breathing runs, the share with , AUC separating them (breathing multiple, robustness value, size) and median breathing multiples.
The method’s error control did not hold on these short awake segments. With each participant’s body signals shifted circularly against their own EEG, which keeps every signal and destroys only their alignment, 12% of the possible brain–heart and brain–other body edges were still declared, against 2–4% in sleep (Table S17); pairing one participant’s EEG with another’s body signals during the same task gave 16–17%, the task acting as a shared driver. The real recordings had 28% and 42%. Awake brain–body edges must therefore be read against these base rates, not against the nominal 5%.
On the same 65 rest and guided-breathing segments (Table S22), RMGC declared breathing heart rate in 82% of the guided-breathing segments, against 68% for the grid VAR, 32% for multiscale Granger causality and 54% for PCMCI (70% against 30–62% at rest). It declared about as many edges as the grid VAR (32 and 31 per segment) but more that appeared with breathing hidden (2.21 per guided-breathing segment, against 0.64–1.43), and most of the brain–heart ones (0.79, against at most 0.46): its sensitivity to slow, breathing-mediated dependence cuts both ways. LPCMCI did not finish in 118 of its 130 runs, even with half its lags; we did not run it without a limit, so on these recordings it was not computationally feasible.
| Method | Guided breathing | Guided breathing | Guided breathing | Rest | Rest | Rest |
| Breathing HR | Sensitive | Brain–heart sensitive | Breathing HR | Sensitive | Brain–heart sensitive | |
| Grid VAR | 68% | 1.43 | 0.46 | 62% | 1.08 | 0.19 |
| Multiscale GC | 32% | 0.82 | 0.00 | 30% | 1.35 | 0.05 |
| PCMCI | 54% | 0.64 | 0.14 | 62% | 0.49 | 0.08 |
| LPCMCI† | 0% | 1.11 | 0.00 | 0% | 0.78 | 0.03 |
| RMGC | 82% | 2.21 | 0.79 | 70% | 2.30 | 0.76 |
Table S22. Established methods and RMGC on the same awake segments: share of segments declaring breathing heart rate (with breathing), and breathing-sensitive edges per segment (all, and brain–heart). †Did not finish in 118 of 130 runs; its values are not interpretable. The grid VAR, multiscale GC and PCMCI test each pair once.
At group level (prevalence across participants), the edges present in most participants were, in every task group, the twelve directed pairs between the four EEG regions; breathing heart rate joined them only during guided breathing. No brain–heart edge was present in most participants in any task.
References
- [1]Carsten Allefeld, Kai Görgen, and John-Dylan Haynes. Valid population inference for information-based imaging: From the second-level t-test to prevalence inference. NeuroImage, 141:378–392, 2016. doi: 10.1016/j.neuroimage.2016.07.040.DOI
- [2]Charles K. Assaad, Emilie Devijver, and Eric Gaussier. Entropy-based discovery of summary causal graphs in time series. Entropy, 24(8):1156, 2022. doi: 10.3390/e24081156.DOI
- [3]David Attwell, Alastair M. Buchan, Serge Charpak, Martin Lauritzen, Brian A. MacVicar, and Eric A. Newman. Glial and neuronal control of brain blood flow. Nature, 468:232–243, 2010.DOI
- [4]Damiano Azzalini, Ignacio Rebollo, and Catherine Tallon-Baudry. Visceral signals shape brain dynamics and cognition. Trends in Cognitive Sciences, 23(6):488–509, 2019.DOI
- [5]Lionel Barnett and Anil K. Seth. Behaviour of Granger causality under filtering: Theoretical invariance and practical application. Journal of Neuroscience Methods, 201(2):404–419, 2011.DOI
- [6]Lionel Barnett and Anil K. Seth. The MVGC multivariate Granger causality toolbox: A new approach to Granger-causal inference. Journal of Neuroscience Methods, 223:50–68, 2014.DOI
- [7]Lionel Barnett and Anil K. Seth. Granger causality for state-space models. Physical Review E, 91:040101, 2015.DOI
- [8]Lionel Barnett and Anil K. Seth. Detectability of Granger causality for subsampled continuous-time neurophysiological processes. Journal of Neuroscience Methods, 275:93–121, 2017. doi: 10.1016/j.jneumeth.2016.10.016.DOI
- [9]Adam B. Barrett and Lionel Barnett. Granger causality is designed to measure effect, not mechanism. Frontiers in Neuroinformatics, 7:6, 2013.DOI
- [10]Ronny P. Bartsch, Kang K. L. Liu, Amir Bashan, and Plamen Ch. Ivanov. Network physiology: How organ systems dynamically interact. PLOS ONE, 10(11):e0142143, 2015.DOI
- [11]Amir Bashan, Ronny P. Bartsch, Jan W. Kantelhardt, Shlomo Havlin, and Plamen Ch. Ivanov. Network physiology reveals relations between network topology and physiological function. Nature Communications, 3:702, 2012.DOI
- [12]Yoav Benjamini and Yosef Hochberg. Controlling the false discovery rate: A practical and powerful approach to multiple testing. Journal of the Royal Statistical Society: Series B, 57(1):289–300, 1995.DOI
- [13]Gary G. Berntson, John T. Cacioppo, and Karen S. Quigley. Respiratory sinus arrhythmia: Autonomic, physiological mechanisms, and psychophysiological implications. Psychophysiology, 30(2):183–196, 1993.pubmed.ncbi.nlm.nih.gov/8434081
- [14]Andrea Bussolan et al. MultiPhysio-HRC: Multimodal physiological signals dataset for industrial human–robot collaboration. Robotics, 14(12):184, 2025.
- [15]Nicholas Carlini and David Wagner. Towards evaluating the robustness of neural networks. In IEEE Symposium on Security and Privacy, pages 39–57, 2017. doi: 10.1109/SP.2017.49.DOI
- [16]Yuxiao Cheng, Lianglong Li, Tingxiong Xiao, Zongren Li, Qin Zhong, Jinli Suo, and Kunlun He. CUTS+: High-dimensional causal discovery from irregular time-series. arXiv:2305.05890, 2023.arxiv.org/abs/2305.05890
- [17]Victor Chernozhukov, Denis Chetverikov, Mert Demirer, Esther Duflo, Christian Hansen, Whitney Newey, and James Robins. Double/debiased machine learning for treatment and structural parameters. The Econometrics Journal, 21(1):C1–C68, 2018.
- [18]Carlos Cinelli and Chad Hazlett. Making sense of sensitivity: Extending omitted variable bias. Journal of the Royal Statistical Society: Series B, 82(1):39–67, 2020.
- [19]Fulvio Corsi. A simple approximate long-memory model of realized volatility. Journal of Financial Econometrics, 7(2):174–196, 2009.
- [20]Francis X. Diebold and Roberto S. Mariano. Comparing predictive accuracy. Journal of Business & Economic Statistics, 13(3):253–263, 1995.
- [21]Charles C. Driver and Manuel C. Voelkle. Hierarchical Bayesian continuous time dynamic modeling. Psychological Methods, 23(4):774–799, 2018.DOI
- [22]Bradley Efron and Robert J. Tibshirani. An Introduction to the Bootstrap. Chapman & Hall, New York, 1993.
- [23]Michael Eichler. Granger causality and path diagrams for multivariate time series. Journal of Econometrics, 137(2):334–353, 2007. doi: 10.1016/j.jeconom.2005.06.032.DOI
- [24]Michael Eichler and Vanessa Didelez. On Granger causality and the effect of interventions in time series. Lifetime Data Analysis, 16(1):3–32, 2010.DOI
- [25]Luca Faes, Giandomenico Nollo, Fabrice Jurysta, and Daniele Marinazzo. Information dynamics of brain–heart physiological networks during sleep. New Journal of Physics, 16(10):105005, 2014.DOI
- [26]Luca Faes, Giandomenico Nollo, Sebastiano Stramaglia, and Daniele Marinazzo. Multiscale Granger causality. Physical Review E, 96:042150, 2017. doi: 10.1103/PhysRevE.96.042150.DOI
- [27]Chenchen Fan, Yixin Wang, Yahong Zhang, and Wenli Ouyang. Interpretable multi-scale neural network for Granger causality discovery. In IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), 2023. doi: 10.1109/ICASSP49357.2023.10096964.DOI
- [28]Andreas Gerhardus and Jakob Runge. High-recall causal discovery for autocorrelated time series with latent confounders. In Advances in Neural Information Processing Systems, volume 33, 2020.arxiv.org/abs/2007.01884
- [29]John Geweke. Measurement of linear dependence and feedback between multiple time series. Journal of the American Statistical Association, 77(378):304–313, 1982.
- [30]Eric Ghysels, Jonathan B. Hill, and Kaiji Motegi. Testing for Granger causality with mixed frequency data. Journal of Econometrics, 192(1):207–230, 2016. doi: 10.1016/j.jeconom.2015.07.007.DOI
- [31]Ary L. Goldberger et al. PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals. Circulation, 101(23):e215–e220, 2000.
- [32]Thomas B. Götz, Alain Hecq, and Stephan Smeekes. Testing for Granger causality in large mixed-frequency VARs. Journal of Econometrics, 193(2):418–432, 2016. doi: 10.1016/j.jeconom.2016.04.015.
- [33]C. W. J. Granger. Investigating causal relations by econometric models and cross-spectral methods. Econometrica, 37(3):424–438, 1969.
- [34]James A. Hanley and Barbara J. McNeil. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology, 143(1):29–36, 1982.pubmed.ncbi.nlm.nih.gov/7063747
- [35]Stefan Haufe, Vadim V. Nikulin, Klaus-Robert Müller, and Guido Nolte. A critical assessment of connectivity measures for EEG data: A simulation study. NeuroImage, 64:120–133, 2013. doi: 10.1016/j.neuroimage.2012.09.036.DOI
- [36]Plamen Ch. Ivanov. The new field of network physiology: Building the human physiome. Frontiers in Network Physiology, 1:711778, 2021.DOI
- [37]Paul Jaccard. The distribution of the flora in the alpine zone. New Phytologist, 11(2):37–50, 1912.
- [38]Claude Julien. The enigma of Mayer waves: Facts and models. Cardiovascular Research, 70(1):12–21, 2006.pubmed.ncbi.nlm.nih.gov/16360130
- [39]Diederik P. Kingma and Jimmy Ba. Adam: A method for stochastic optimization. In International Conference on Learning Representations (ICLR), 2015.arxiv.org/abs/1412.6980
- [40]Peter E. Kloeden and Eckhard Platen. Numerical Solution of Stochastic Differential Equations. Springer, Berlin, 1992.
- [41]Michael C. Lovell. Seasonal adjustment of economic time series and multiple regression analysis. Journal of the American Statistical Association, 58(304):993–1010, 1963.DOI
- [42]Helmut Lütkepohl. New Introduction to Multiple Time Series Analysis. Springer, 2005.
- [43]Jens Madsen, Nikhil Kuppa, and Lucas C. Parra. The brain, body, and behavior dataset (BBBD): Multimodal recordings during educational videos. Zenodo, 2025.DOI
- [44]Marcello Massimini, Reto Huber, Fabio Ferrarelli, Sean Hill, and Giulio Tononi. The sleep slow oscillation as a traveling wave. Journal of Neuroscience, 24(31):6862–6870, 2004. doi: 10.1523/JNEUROSCI.1318-04.2004.DOI
- [45]J. Mateo and P. Laguna. Improved heart rate variability signal analysis from the beat occurrence times according to the IPFM model. IEEE Transactions on Biomedical Engineering, 47(8):985–996, 2000.pubmed.ncbi.nlm.nih.gov/10943046
- [47]Whitney K. Newey and Kenneth D. West. A simple, positive semi-definite, heteroskedasticity and autocorrelation consistent covariance matrix. Econometrica, 55(3):703–708, 1987.DOI
- [48]Alan V. Oppenheim and Ronald W. Schafer. Discrete-Time Signal Processing. Pearson, Upper Saddle River, NJ, 3rd edition, 2010.
- [49]Hyeong-Dong Park, Stéphanie Correia, Antoine Ducorps, and Catherine Tallon-Baudry. Spontaneous fluctuations in neural responses to heartbeats predict visual detection. Nature Neuroscience, 17(4):612–618, 2014.DOI
- [50]Lucas C. Parra, Aimar Silvan, Maximilian Nentwich, Jens Madsen, Vera E. Parra, and Bethash Babadi. VARX Granger analysis: Models for neuroscience, physiology, sociology and econometrics. PLoS ONE, 20(1):e0313875, 2025. doi: 10.1371/journal.pone.0313875.DOI
- [51]Alberto Porta, Tito Bassani, Vlasta Bari, Gian D. Pinna, Roberto Maestri, and Stefano Guzzetti. Accounting for respiration is necessary to reliably infer Granger causality from cardiovascular variability series. IEEE Transactions on Biomedical Engineering, 59(3):832–841, 2012. doi: 10.1109/TBME.2011.2180379.DOI
- [52]Lipeng Qian, Qiong Zuo, Wei Liu, and Hong Zhu. MSDG: A multiscale dynamic graph neural network for inferring dynamic Granger causality in multivariate time series. Information Sciences, 741:123287, 2026. doi: 10.1016/j.ins.2026.123287.DOI
- [53]Jakob Runge, Peer Nowack, Marlene Kretschmer, Seth Flaxman, and Dino Sejdinovic. Detecting and quantifying causal associations in large nonlinear time series datasets. Science Advances, 5 (11):eau4996, 2019.DOI
- [54]Skipper Seabold and Josef Perktold. statsmodels: Econometric and statistical modeling with Python. In Proceedings of the 9th Python in Science Conference, 2010.DOI
- [55]Gideon Stein, Niklas Penzel, Tristan Piater, and Joachim Denzler. TCD-Arena: Assessing robustness of time series causal discovery methods against assumption violations. In International Conference on Learning Representations (ICLR), 2026. arXiv:2605.03045.arxiv.org/abs/2605.03045
- [56]Patrick A. Stokes and Patrick L. Purdon. A study of problems encountered in Granger causality analysis from a neuroscience perspective. Proceedings of the National Academy of Sciences, 114 (34):E7063–E7072, 2017.DOI
- [57]Alex Tank, Emily B. Fox, and Ali Shojaie. Identifiability and estimation of structural vector autoregressive models for subsampled and mixed-frequency time series. Biometrika, 106(2):433–452, 2019. doi: 10.1093/biomet/asz007.DOI
- [58]Alex Tank, Ian Covert, Nicholas Foti, Ali Shojaie, and Emily B. Fox. Neural Granger causality. IEEE Transactions on Pattern Analysis and Machine Intelligence, 44(8):4267–4279, 2022. doi: 10.1109/TPAMI.2021.3065601.DOI
- [59]Mario Giovanni Terzano et al. Atlas, rules, and recording techniques for the scoring of cyclic alternating pattern (CAP) in human sleep. Sleep Medicine, 2(6):537–553, 2001.
- [60]George E. Uhlenbeck and Leonard S. Ornstein. On the theory of the Brownian motion. Physical Review, 36(5):823–841, 1930.DOI
- [61]Abhinav Uppal et al. Brain-body coupling in listening to metronomic sounds and music. In 47th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2025. doi: 10.1109/EMBC58623.2025.11251651.DOI
- [62]Pauli Virtanen et al. SciPy 1.0: Fundamental algorithms for scientific computing in Python. Nature Methods, 17:261–272, 2020.
- [63]Irene Winkler, Danny Panknin, Daniel Bartz, Klaus-Robert Müller, and Stefan Haufe. Validity of time reversal for testing Granger causality. IEEE Transactions on Signal Processing, 64(11):2746–2760, 2016. doi: 10.1109/TSP.2016.2531628.DOI
- [64]Christina Zelano, Heidi Jiang, Guangyu Zhou, Nikita Arora, Stephan Schuele, Joshua Rosenow, and Jay A. Gottfried. Nasal respiration entrains human limbic oscillations and modulates cognitive function. Journal of Neuroscience, 36(49):12448–12467, 2016.pubmed.ncbi.nlm.nih.gov/27927961
- [65]Kun Zhu, Chunhui Zhao, and Biao Huang. Breaking information granularity heterogeneity: A mutual information-inspired causal discovery framework for multi-rate time series. IEEE Transactions on Knowledge and Data Engineering, 37(12):7001–7015, 2025. doi: 10.1109/TKDE.2025.3618763.DOI