WorksComputer Science
Time-JEPA: Grounding Video World Models with Physical Time Series
Abstract
Video world models learn how visual environments evolve by predicting missing or future content. However, physical-state information can provide useful context for predicting how environments evolve. Prior work incorporates this information through different mechanisms: domain-specific physical laws can complicate multi-domain training, while supervision on individual frames or frame pairs gives limited attention to how physical state evolves over time. We introduce Time-JEPA, which fine-tunes a video world model using low-dimensional, temporally aligned physical time series as auxiliary supervision. Physical time series connect video representations with physical state at corresponding temporal positions, encouraging the model to preserve how physical state evolves. In multiple domains including autonomous driving, robot manipulation, and human motion, Time-JEPA improves current-state decoding, multi-horizon future-state prediction, and kinematic reconstruction over matched video-fine-tuned controls across both condition and state-variable distribution shifts. Multi-domain training provides aggregate gains over matched single-domain training in all three tasks. External evaluations further suggest that time-series supervision improves sensitivity to physical anomalies and the representation of physical interactions, including in unseen scenarios. Aggregate gains on a second video backbone indicate that the method can be applied to more backbones. These results suggest that physical time series help video world models better understand the physical world.
Code: https://github.com/Lishenyi2004/Time-JEPA
Introduction
Video world models learn how visual environments evolve by predicting missing or future content. Common approaches include masked video autoencoders, which reconstruct hidden pixels ([24, 10]), and latent-prediction video models such as V-JEPA ([6, 4]). V-JEPA builds on the joint-embedding predictive architecture (JEPA) ([3]) to predict masked spatiotemporal target representations from visible video context. The resulting representations encode objects, motion, and events. However, predicting how an event unfolds also requires information about physical state. A car can follow the same turn at different speeds and produce different future motion, and visually similar grasps can involve different joint configurations or forces. The speeds, joint configurations, and forces in these examples form part of the physical state and help video world models understand how events unfold.
Prior work incorporates physical state into video world models in two main ways. Some methods use physical laws or system-specific dynamical priors to constrain how physical state evolves [13, 18]. Because these constraints rely on domain-specific formulations, equations, and knowledge, one training design cannot easily cover multiple domains. Moreover, certain physical constraints can make the model focus on the dynamics they describe and miss other changes in videos. Others use geometric structure, motion cues, or privileged state as prediction or alignment targets to capture different aspects of physical state [20, 22, 23, 31, 29, 27]. This way reduces reliance on explicit physical laws. However, this way often focuses supervision on individual frames or frame pairs, giving limited attention to how physical state evolves within a video’s full temporal context. Besides, such methods often require additional input signals, making the training setup more complex. Therefore, overcoming these limitations requires a common interface and readily available data that can serve as physical state.
We introduce Time-JEPA, a method that aligns physical-state with the temporal structure of video. We apply a shared interface for multiple domains and use physical time series that sensors often easily provide alongside video. It is noted that time series only serve as auxiliary supervision during training and video remains as the model’s only input during evaluation. We evaluate Time-JEPA in multiple domains including autonomous driving, robot manipulation, and human motion. Compared with matched video-fine-tuned controls, Time-JEPA improves current-state decoding, multi-horizon future-state prediction, and kinematic reconstruction. The gains hold under two levels of out-of-distribution evaluation: unseen test conditions, and state variables not used as auxiliary training targets. Multi-domain training provides aggregate gains over matched single-domain training in all three tasks. External evaluations further suggest that time-series supervision improves sensitivity to physical anomalies and the representation of physical interactions, including in unseen scenarios. Aggregate gains on a second video backbone indicate that the method can be applied to more backbones. These results indicate that physical time series help video world models better understand the physical world.
We make two contributions:
Physical time-series supervision for video world models. We introduce Time-JEPA, which combines latent prediction with temporally aligned physical time-series supervision through a shared interface. We set up in-distribution (ID) and out-of-distribution (OOD) settings at two levels, including conditions and variables.
Datasets and toolkit in multiple domains. We construct datasets for multiple domains including autonomous driving, robot manipulation, and human motion. We develop a toolkit for video world models that combines current-state decoding, multi-horizon future-state prediction, and kinematic reconstruction to more thoroughly assess their ability to represent physical states, including physical relations and state evolution.
Related Work
Predictive video representations and world models. Video world models learn representations of visual environments through pixel reconstruction or latent prediction. For pixel reconstruction, masked video autoencoders [24, 10] reconstruct hidden pixels, and VideoMAE V2 [26] scales this objective through dual masking. For latent prediction, V-JEPA [6] follows JEPA [3] and predicts target-encoder representations at masked spatiotemporal positions. V-JEPA 2 [4] and V-JEPA 2.1 [19] develop this family for motion understanding and dense feature extraction. InternVideo-Next [25] combines reconstruction and latent prediction. Dreamer [15] and iVideoGPT [28] learn action-conditioned dynamics for control and interactive video prediction. Time-JEPA builds on V-JEPA’s masked latent-prediction objective and adds time-series supervision during fine-tuning.
Signals for visual learning. Prior work uses auxiliary supervision from scene state, egomotion, and other modalities to shape visual representations [9, 1, 14]. One route incorporates physical equations or dynamical priors into latent prediction, as in PhyDNet [13] and PIWM [18]. A second route adds prediction or alignment targets, including physical state in Dynamics Mapping [20], depth and keypoint trajectories in RoboScape [22], and V-JEPA-derived latents in PHANTOM [23]. PhyLatent [31] and PSG-JEPA [29] add physical-state supervision to action-conditioned JEPA prediction, while JEPA-x [27] couples visual and physical trajectories through cross-modal future prediction. Time-JEPA uses low-dimensional, temporally aligned physical time series as auxiliary supervision through a shared interface across autonomous driving, robot manipulation, and human motion. Sensors or synchronized annotations supply these time series, and the encoder uses video as its only input during fine-tuning and evaluation.
Evaluating physical information in video representations. PHYRE [5] and CLEVRER [30] evaluate physical reasoning about interacting objects and collision events. Physion [7] tests future-contact prediction, and GRASP [16] evaluates intuitive-physics properties with matched possible and impossible videos. Studies of self-supervised video predictors examine intuitive physics and probe physical-state information in frozen video representations [11, 17, 21]. Our evaluation combines continuous current-state decoding, kinematic reconstruction, and multi-horizon future-state prediction with external tests on GRASP and Physion.
Method: Time-JEPA
Overview. We propose Time-JEPA, a fine-tuning approach that uses temporally aligned physical time-series supervision to encourage predictive video representations to preserve information about physical state as it evolves. As shown in Figure 1, Time-JEPA couples two learning paths through a shared online video encoder. The predictive video representation module builds on V-JEPA and predicts latent representations at masked positions. An exponential-moving-average (EMA) target encoder computes these representations from the full clip. The physical time-series preparation module maps synchronized measurements to video time, and the physical time-series supervision module regresses the aligned state from full-clip video features. Both objectives update the same online encoder, coupling masked latent prediction with tubelet-level physical-state supervision. The physical time series provide auxiliary supervision during fine-tuning, and video remains the encoder input throughout fine-tuning and evaluation.
Figure 1. Time-JEPA training and evaluation. Training combines masked latent prediction with regression of aligned, pooled, and normalized physical state values from full-clip video features. The EMA target encoder supplies latent supervision. Video-only evaluation covers current-state decoding, multi-horizon future-state prediction, kinematic reconstruction, and external physical evaluations.
Predictive Video Representation
The predictive video representation module builds on the masked latent-prediction objective of V-JEPA [6]. For each clip, the online encoder transforms a masked video view into latent patch tokens. Its final-layer representation indexes these tokens by temporal position and spatial patch location. The predictor estimates latent tokens at the masked positions. The EMA target encoder processes the full clip and provides the corresponding latent tokens. The JEPA loss measures prediction error at the masked positions and updates the online encoder and predictor. The exponential moving average updates the target encoder parameters from the online encoder.
Physical Time-Series Preparation
The physical time-series preparation module maps physical time series from sensors or synchronized annotations to the encoder’s temporal grid. These time series record measurements such as vehicle speed, robot joint configuration, and human joint angle over time. We associate each sampled video time with nearby physical measurements using timestamps or frame indices, then group the aligned measurements according to the encoder’s tubelet structure. Within each tubelet, we pool each type of physical measurement across its sampled times. We then normalize the pooled measurements to place different numerical scales in a common space, producing a sequence of tubelet-level state values. This preparation aligns each temporal video feature with the corresponding physical measurements even when their sampling rates differ. Appendix C gives the shared alignment, pooling, validity, and normalization details.
Physical Time-Series Supervision
In the physical time-series supervision module, we process the unmasked video clip with the shared online encoder. The online encoder’s final layer organizes patch tokens along temporal positions and spatial patch locations. At each temporal position, Time-JEPA then applies mean pooling across spatial patch locations to produce one pooled temporal feature. An auxiliary physical-state regression head applies a two-layer pointwise nonlinear projection independently to each pooled temporal feature and regresses normalized state values for the corresponding tubelet. This minimal pointwise design concentrates temporal representation learning in the online encoder. We compute the time-series regression loss as a validity-masked Smooth-L1 error between the auxiliary-head outputs and their aligned state values.
We combine the two learning paths through the joint objective , where controls the contribution of the time-series loss. Under this objective, the JEPA loss guides masked latent prediction, while the time-series loss encourages the online encoder to model how physical state evolves across the video clip.
Evaluation with Video-Only Input
After fine-tuning, we discard the auxiliary head and freeze the online encoder. We train state probes on its final-layer features from video-only input. For current-state decoding and future-state prediction, these probes apply spatial mean pooling followed by two pointwise convolutional layers. Current-state decoding measures how accurately the encoders recover physical states within the observed clip. Multi-horizon future-state prediction estimates physical states at multiple times beyond the observed clip. Kinematic reconstruction evaluates physical relations among the outputs of separate state probes. External physical evaluations assess transfer to physical tasks beyond the fine-tuning datasets. § 4–§ 7 detail the evaluation protocols.
Experimental Setup
Comparisons
To evaluate the effects of video fine-tuning and time-series supervision, we compare three configurations based on the released V-JEPA 2.1 ViT-g/16 model (Mur-Labadia et al. [19]): (i) The pretrained V-JEPA model (original V-JEPA); (ii) V-JEPA fine-tuned using video data and (video-fine-tuned control); (iii) Time-JEPA that uses the same video data and fine-tuning protocol, while adds supervision from temporally aligned physical time series and optimizes the time-series regression loss together with .
Domains, Variables, and Splits
We study autonomous driving, robot manipulation, and human motion using the CoVLA (Arai et al. [2]), AgiBot (Bu et al. [8]), and EgoExo4D (Grauman et al. [12]) datasets, respectively. Across the three domains, we pair video with physical time series and define two ID/OOD axes: conditions and state variables. Seen and held-out conditions or camera views define and , respectively. State variables used and not used in auxiliary time-series supervision define and , respectively.
Autonomous driving uses speed and acceleration for vehicle dynamics, caption-defined stable rain for , and steering and lateral motion for . Robot manipulation uses robot motion and gripper state for robot proprioception, held-out fisheye views for , and joint state, effort, and wrench for . Human motion uses body motion and joint angles for pose-derived human kinematics, the held-out exocentric view03 for , and pose-derived body geometry for . Figure 2 summarizes the video data and physical time series. Appendix D gives the state-variable definitions and split construction.

Figure 2. Video–state data composition. Each column summarizes one domain’s video data for fine-tuning, two-level ID/OOD settings for conditions and state variables, and representative physical time series.
Common Experimental Settings
We sample 64 frames at 5 FPS per clip for fine-tuning and evaluation in multiple domains. We use task-specific probes throughout our evaluations. We first train each probe on the probe-training split and then test it on the corresponding test split. We normalize state values in the probe-training, probe-validation, and test splits using statistics from the probe-training split to keep each variable on a consistent scale. Appendix A gives the full fine-tuning and probe protocols.
For multi-domain Time-JEPA, we share one encoder in multiple domains and assign an auxiliary head to each domain. Each domain follows the same per-domain training settings as its matched single-domain run, while the shared encoder processes the combined stream. Appendix F gives the multi-domain scheduling.
Physical-State Decoding and Prediction
Time-Series Supervision Across Variables and Conditions
This section investigates how accurately the encoders recover physical states within the observed clip. We compare the three configurations from § 4.1 across the state-variable and condition axes defined in § 4.2. Table 1 reports Pearson and in three domain column groups, with ID results in the upper block and OOD results in the lower block.
| Condition | Variables | Metric | autonomous driving Original | autonomous driving Video FT | autonomous driving Time-JEPA | robot manipulation Original | robot manipulation Video FT | robot manipulation Time-JEPA | human motion Original | human motion Video FT | human motion Time-JEPA |
| ID | ID | 0.804 | 0.817 | 0.916 | 0.609 | 0.639 | 0.845 | 0.500 | 0.503 | 0.589 | |
| 0.698 | 0.713 | 0.849 | 0.389 | 0.424 | 0.725 | 0.228 | 0.231 | 0.345 | |||
| OOD | 0.879 | 0.885 | 0.920 | 0.641 | 0.654 | 0.743 | 0.434 | 0.434 | 0.504 | ||
| 0.771 | 0.783 | 0.846 | 0.422 | 0.440 | 0.572 | 0.132 | 0.133 | 0.222 | |||
| OOD | ID | 0.800 | 0.812 | 0.902 | 0.236 | 0.243 | 0.492 | 0.480 | 0.486 | 0.581 | |
| 0.685 | 0.699 | 0.824 | 0.002 | −0.001 | 0.085 | 0.189 | 0.199 | 0.332 | |||
| OOD | 0.894 | 0.901 | 0.937 | 0.373 | 0.402 | 0.555 | 0.450 | 0.452 | 0.515 | ||
| 0.799 | 0.812 | 0.876 | 0.093 | 0.127 | 0.205 | 0.127 | 0.135 | 0.225 |
Table 1. Current-state decoding across variables and conditions. We compare the three V-JEPA configurations on ID and OOD state variables under ID and OOD conditions. We compute metrics for each variable and camera view, then average equally over views and over variables. Bold marks the highest score in each comparison. Appendix B gives variable-level and domain results.
Across all three domains, Time-JEPA improves both Pearson and over the video-fine-tuned control for ID under ID. These gains extend to OOD, OOD, and their combination. For OOD under OOD, rises from 0.812 to 0.876, 0.127 to 0.205, and 0.135 to 0.225 in the three domains. The joint-OOD gains extend the current-state decoding benefit to simultaneous variable- and condition-level distribution shifts.
Table 2 aggregates the matched iVideoGPT [28] comparison across domains using the same settings from Time-JEPA. We retain iVideoGPT’s video-prediction objective, add an auxiliary head to regress temporally aligned physical states during fine-tuning, and remove the head before
Table 2: iVideoGPT current-state decoding. Setting: variable*condition. We average views and variables, then weight domains by 30 or 16 dimensions.
| Setting | Metric | Original | Video FT | Time |
| 0.360 | 0.441 | 0.557 | ||
| 0.136 | 0.208 | 0.328 | ||
| 0.415 | 0.481 | 0.561 | ||
| 0.184 | 0.253 | 0.341 | ||
| 0.157 | 0.165 | 0.219 | ||
| 0.007 | 0.042 | |||
| 0.214 | 0.253 | 0.313 | ||
| 0.014 | 0.070 | 0.113 |
Table 2.
video-only probing. Relative to matched Video FT, our method improves both metrics in all four aggregate settings and 10 of 12 domain panels (Appendix § 13). These results suggest that the method has some transferability across video world models and can be applied to more backbones.
To gauge the difficulty of current-state decoding under held-out conditions, we also evaluate two original video backbones, InternVideo-Next-L ([25]) and VideoMAE V2-G ([26]). Appendix § 13 gives their results. In Appendix § 22, we compare Time-JEPA with methods supervised on individual frames or frame pairs, and separately evaluate the effect of adding explicit physical-law constraints to Time-JEPA. These comparisons are consistent with the concerns raised in the Introduction: frame- and frame-pair supervision may underuse full-video temporal context, while a specific physical-law constraint can improve its targeted relation without improving broader physical-state estimates. We also report component ablations and sensor sensitivity in Appendices § 20 and § 21.
Multi-Domain Training
To evaluate Time-JEPA’s shared target interface for multi-domain training, we jointly fine-tune one encoder with physical time-series supervision from all three domains. We compare multi-domain Time-JEPA with matched single-domain encoders under the same per-domain training schedules in Figure 3. Across all three domains, multi-domain Time-JEPA improves both metrics for under . The gains extend to , , and their combination. Specifically, for under , increases by 0.047, 0.063, and 0.231 in autonomous driving, robot manipulation, and human motion, respectively. These results show that Time-JEPA can use a shared interface to benefit from multi-domain physical time-series supervision and further improve physical-state decoding. Appendix § 17 provides detailed results and further analysis. The results show the same multi-domain advantage for future-state prediction and kinematic reconstruction, so we use the multi-domain setting for all subsequent tasks.

Figure 3. Current-state decoding gains from multi-domain training. (a) Pearson gains and (b) gains of multi-domain Time-JEPA over matched single-domain training. Colors identify the four variable/condition settings in the legend. Labels report absolute gains.
Future-State Prediction
Section 5.1 evaluates current-state decoding within the observed clip. Multi-horizon future-state prediction extends this evaluation beyond the clip and tests whether the representation captures how physical state evolves. Let denote the time of the final observed frame. A probe on features from each frozen online encoder predicts physical states at .
We use the three configurations from Section 4.1 and the multi-domain training setting from Section 4.3. We train probes with future labels for the state-variable groups defined in Section 4.2. Table 3 reports nRMSE and across both the state-variable and condition axes.
Table 3: Multi-domain V-JEPA future-state prediction. Setting: variable*condition. We average five horizons, then weight domains by 30 or 16 dimensions.
| Setting | Metric | Original | Video FT | Time-JEPA |
| nRMSE | 0.857 | 0.846 | 0.651 | |
| 0.280 | 0.296 | 0.550 | ||
| nRMSE | 0.873 | 0.861 | 0.732 | |
| 0.254 | 0.272 | 0.463 | ||
| nRMSE | 0.953 | 0.949 | 0.875 | |
| 0.100 | 0.104 | 0.202 | ||
| nRMSE | 0.930 | 0.911 | 0.844 | |
| 0.117 | 0.153 | 0.235 |
Table 3.
Relative to the video-fine-tuned control, Time-JEPA reduces aggregate nRMSE and increases aggregate for under . These improvements extend to , , and their combination. Under , nRMSE falls from 0.949 to 0.875 for and from 0.911 to 0.844 for . These results extend the current-state decoding gains to future-state prediction, includ-
ing the joint setting. These results definitely demonstrate a better understanding of state evolution. Appendix § 18 provides further details on these comparisons.
Kinematic Reconstruction
Beyond decoding individual physical states, we evaluate whether the video representation captures the physical relations that connect them. We use the three configurations from § 4.1 and the multi-domain training setting from § 4.3. Kinematic reconstruction applies fixed physical laws to predictions from separate probes and compares the reconstructed states with ground truth. Following § 3.4, we train these probes on features from the frozen online encoder. Each probe learns its own parameters to predict one physical state and we use the physical laws only at evaluation, after encoder fine-tuning and probe training. Table 4 reports the primary reconstruction error for the three configurations under and in all three domains. Each domain uses its own physical law and unit, so we compare the configurations within each row.
Table 4: Primary kinematic reconstruction errors. Mean sample standard deviation across five probe seeds. Within each seed, trajectory, reach-rate, and distance MAE average three horizons, two arms, and four limbs, respectively. Video FT and Time-JEPA use multi-domain training. Bold marks the lowest error per row.
| Condition | Domain | Metric | Original | Video FT | Time-JEPA |
| autonomous driving | Trajectory MAE (m) | ||||
| robot manipulation | Reach-rate MAE (cm/s) | ||||
| human motion | Distance MAE (cm) | ||||
| autonomous driving | Trajectory MAE (m) | ||||
| robot manipulation | Reach-rate MAE (cm/s) | ||||
| human motion | Distance MAE (cm) |
Table 4. Primary kinematic reconstruction errors. Mean sample standard deviation across five probe seeds. Within each seed, trajectory, reach-rate, and distance MAE average three horizons, two arms, and four limbs, respectively. Video FT and Time-JEPA use multi-domain training. Bold marks the lowest error per row.
For autonomous driving, integrated trajectory reconstruction follows the physical laws linking vehicle velocity and yaw rate to changes in position and heading. We integrate longitudinal and lateral velocity predictions with yaw-rate predictions from separate probes to recover trajectory endpoints. We average endpoint MAE across three horizons. Relative to the video-fine-tuned control, Time-JEPA lowers trajectory MAE in both condition settings, with MAE falling from 4.150 to 1.858 m.
For robot manipulation, reach-rate reconstruction estimates how quickly the distance between the shoulder and hand changes. We use joint-angle predictions and the robot’s fixed geometry to determine the shoulder-to-hand direction, then project hand-velocity predictions onto this direction. We average signed reach-rate MAE across both arms within each probe seed. Time-JEPA also lowers reach-rate MAE under both condition settings. Under , it reduces the error from 5.822 cm/s for the video-fine-tuned control to 4.171 cm/s.
For human motion, the cosine law connects joint angles and limb segment lengths to distances between limb endpoints. We therefore combine elbow and knee angle predictions with segment lengths to recover shoulder-to-wrist and hip-to-ankle distances through cosine-law distance reconstruction. We average distance MAE across both arms and both legs. Time-JEPA achieves lower distance MAE than the video-fine-tuned control in both condition settings, including a decrease from 7.120 to 4.557 cm under .
These smaller errors show that Time-JEPA’s encoder learns video representations that support more accurate kinematic reconstructions and capture physical relations more effectively. Appendix § 16 provides the equations, ground-truth validation, and detailed results.
External Physical Evaluations
To examine transfer to external physical tasks, we evaluate Time-JEPA on GRASP and Physion. GRASP tests sensitivity to physical anomalies, and Physion tests future-contact prediction (Figure 4). These two evaluations complement the decoding, prediction, and reconstruction tasks and broaden our assessment of Time-JEPA’s physical generalization.

Figure 4. External physical evaluations. (a) GRASP Level 2 eight-property macro pair accuracy over 2,048 matched possible–impossible pairs; bars show points above 50% chance and labels give absolute accuracy. (b,c) Physion v1.5 scenario-macro Accuracy and AUROC (%) with chronological input, averaged equally over seven scenarios.
GRASP: Violation-of-Expectation Prediction
GRASP Level 2 contains 2,048 matched possible–impossible video pairs from 16 test families spanning eight intuitive-physics properties (Jassim et al. [16]). We use the three configurations from § 4.1 and the multi-domain training setting from § 4.3. We freeze the online encoder, target encoder, and predictor for every configuration.
We compute latent prediction error between predicted and target latent features, then average the window errors to obtain AverageSurprise for each video. For each pair, we classify the video with higher AverageSurprise as impossible. Our primary metric averages pair accuracy equally across the eight properties. Figure 4 reports the three external-physical evaluation panels. Time-JEPA reaches 57.8%, exceeding the matched video-fine-tuned control by 2.2 percentage points. This gain suggests that time-series supervision improves sensitivity to physical anomalies. Appendix § 19 provides the full protocol and property-level results.
Physion: Future Contact
On Physion (Bear et al. [7]), we use the same configurations to predict whether two designated objects will make contact after four observed frames. We provide the frames in chronological order and train the probe on frozen target-encoder features. The all-scenario readout includes all seven scenario types in probe training, while leave-one-scenario-out transfer trains each probe on six types and tests it on the remaining type.
Figure 4 reports Accuracy and AUROC for both Physion readout protocols. AUROC (area under the receiver operating characteristic curve) measures how often the probe assigns a higher contact probability to a true contact case than to a true non-contact case. Although Time-JEPA achieves nearly identical Accuracy to the video-fine-tuned control in the all-scenario readout, it increases AUROC by 1.182 percentage points. The gains extend to both metrics in leave-one-scenario-out transfer, where Time-JEPA improves Accuracy and AUROC by 2.945 and 3.997 percentage points over the same control. These results suggest that time-series supervision supports a better understanding of physical interactions, including in unseen scenarios. Appendix § 19 provides further results and protocol details.
Conclusion
We introduced Time-JEPA, which shapes video representations using low-dimensional, temporally aligned physical time series as auxiliary supervision during fine-tuning. Its shared interface supports multi-domain training, and video remains the encoder’s only input. In multiple domains, Time-JEPA improves current-state decoding, multi-horizon future-state prediction, and kinematic reconstruction over matched video-fine-tuned controls across both condition and state-variable distribution shifts. Multi-domain training provides aggregate gains over matched single-domain training in all three tasks. External evaluations further suggest that time-series supervision improves sensitivity to physical anomalies and the representation of physical interactions, including in unseen scenarios. Aggregate gains on a second video backbone indicate that the method can be applied to more backbones. These findings suggest that time series help video world models better understand how events unfold. Future work can extend this interface to richer physical time series and action-conditioned settings.
AI USE STATEMENT
We used generative AI tools to assist with writing code and polishing the wording of this manuscript. The authors reviewed the AI-assisted code and text and take responsibility for the final content of this work.
ETHICS STATEMENT
We use previously released datasets, including human activity videos and associated pose annotations. Such recordings can contain identifiable people; reuse of the source data and any derived materials should respect the datasets’ access terms and participant privacy. Our study reports aggregate results from offline video evaluations and does not test real-world vehicle or robot control. The reported scores do not establish safety for deployment in those settings.
REPRODUCIBILITY STATEMENT
Appendix A documents the fine-tuning and probing setup and checkpoint selection. Appendices B–K provide the variable-level results, common time-series preprocessing, dataset definitions and splits, kinematic-reconstruction formulas, multi-domain training details, future and downstream protocols, additional-backbone comparisons, and ablations needed to reproduce the reported comparisons.
Implementation and Reproducibility
Fine-Tuning Protocol
All main V-JEPA comparisons start from the same pretrained model. The video-fine-tuned control and Time-JEPA share the configuration and sampling distributions, with independent draws of clips, crops, and JEPA masks. Time-JEPA adds the auxiliary head and time-series loss.
| Setting | Details |
| Video input | 64 frames at 5 FPS, crop, patch size 16, tubelet size 2, 32 temporal tokens, and strict temporal sampling. |
| Sampling | All domains use the same 64-frame, 5-FPS temporal context (12.6 s between the first and last sampled frames). Valid start times are constructed from each source timeline: a random offset within each selected autonomous-driving video, or a timestamp-aligned grid with 12.8 s spacing for robot manipulation and human motion. |
| Augmentation | Random resized crop with scale [0.3, 1.0] and aspect ratio [0.75, 1.35]. We retain the original horizontal orientation. |
| Optimization | 20 epochs, batch size 8 per GPU, AdamW, learning rate with one warmup epoch and cosine decay, weight decay 0.01, bfloat16, and EMA momentum . |
| JEPA masks | Eight block masks with spatial scale 0.15 and two with spatial scale 0.70. All use temporal scale 1.0. |
| Time-series supervision | A separate unmasked online-encoder pass supplies the final-layer patch grid. A two-layer pointwise nonlinear auxiliary head with GELU regresses aligned states under a masked Smooth-L1 loss (). The loss weight warms up linearly over the first 250 domain steps. |
| Time-series loss weight | for autonomous driving and for robot manipulation and human motion. Multi-domain training retains these domain-specific values. |
| Random seed | 239 for every main fine-tuning run. |
Table A1. Matched V-JEPA fine-tuning recipe. Time-JEPA adds the time-series supervision branch and its loss to the shared settings. Domain steps count batches from the corresponding domain.
Probe Training on Frozen Encoders and Aggregation
For each encoder and current-state task, we freeze the encoder and train a new pointwise nonlinear probe for 15 epochs. The probe uses AdamW with a learning rate of , cosine decay to , one warmup epoch, and weight decay 0.01. Batch size is 16 for autonomous driving and 8 for robot manipulation and human motion. We select each probe by validation loss, then evaluate it under and . Both tests reuse the probe-training normalization statistics and fitted probe parameters.
We compute each metric per state variable and view, average views equally, then average variables equally. We average these eight view–variable entries equally. Kinematic-reconstruction probes use the same optimizer schedule and domain-specific batch sizes.
Full Current-State Results
Table B1 gives the iVideoGPT (Wu et al., [28]) domain scores behind Table 2. Time-JEPA improves Pearson and over Video FT in 10 of 12 domain panels. The two exceptions occur under the held-out fisheye views in robot manipulation. Table B2 uses the original InternVideo-Next-L (Wang et al., [25]) and VideoMAE V2-G (Wang et al., [26]) encoders to gauge the difficulty of held-out current-state decoding, alongside the Time-JEPA encoder for comparison. Both original backbones score lower under the robot manipulation fisheye views than under the seen views across both variable groups and metrics. Their lower held-out-condition scores support the difficulty of our task setting.
Tables B3–B8 expand Table 1 to variable-level V-JEPA results and include nRMSE. ID denotes state variables included in auxiliary time-series supervision, and OOD denotes those excluded from it. Each result comes from one supervised probe on a frozen encoder. Bold marks the best unrounded value for each variable, condition, and metric. Time-JEPA improves all three variable-macro metrics in all 12 V-JEPA panels.
Table B1: Current-state decoding and transfer with iVideoGPT. The three configurations use one matched probe run at native resolution and Table 1’s view/variable aggregation. Bold marks the best unrounded value.
| Condition | Variables | Metric | autonomous driving Original | autonomous driving Video FT | autonomous driving Time | robot manipulation Original | robot manipulation Video FT | robot manipulation Time | human motion Original | human motion Video FT | human motion Time |
| ID | ID | 0.466 | 0.563 | 0.757 | 0.362 | 0.457 | 0.570 | 0.320 | 0.370 | 0.462 | |
| ID | ID | 0.260 | 0.403 | 0.654 | 0.145 | 0.223 | 0.342 | 0.076 | 0.115 | 0.193 | |
| ID | OOD | 0.576 | 0.730 | 0.857 | 0.425 | 0.495 | 0.564 | 0.303 | 0.311 | 0.379 | |
| ID | OOD | 0.322 | 0.526 | 0.736 | 0.199 | 0.265 | 0.339 | 0.078 | 0.068 | 0.108 | |
| OOD | ID | 0.441 | 0.552 | 0.727 | 0.077 | 0.040 | 0.034 | 0.223 | 0.286 | 0.419 | |
| OOD | ID | 0.225 | 0.380 | 0.608 | −0.065 | −0.068 | −0.103 | −0.031 | 0.032 | 0.144 | |
| OOD | OOD | 0.525 | 0.728 | 0.858 | 0.109 | 0.097 | 0.090 | 0.195 | 0.218 | 0.344 | |
| OOD | OOD | 0.269 | 0.522 | 0.735 | −0.060 | −0.057 | −0.096 | −0.019 | 0.002 | 0.075 |
Table B1.
Table B2: Current-state task difficulty and Time-JEPA comparison. We evaluate original pretrained InternVideo-Next-L and VideoMAE V2-G encoders alongside the Time-JEPA encoder at their native input resolutions, using Table 1’s splits, supervised-probe protocol, and aggregation. The column labels “I-Next-L,” “VMAE V2-G,” and “Time-JEPA” denote InternVideo-Next-L, VideoMAE V2-G, and Time-JEPA, respectively. Variable and condition notation follows § 4.2. Bold marks the best unrounded value among the listed encoders.
| Condition | Variables | Metric | autonomous driving I-Next-L | autonomous driving VMAE V2-G | autonomous driving Time-JEPA | robot manipulation I-Next-L | robot manipulation VMAE V2-G | robot manipulation Time-JEPA | human motion I-Next-L | human motion VMAE V2-G | human motion Time-JEPA |
| ID | ID | 0.662 | 0.613 | 0.916 | 0.557 | 0.324 | 0.845 | 0.536 | 0.354 | 0.589 | |
| ID | ID | 0.475 | 0.429 | 0.849 | 0.345 | 0.128 | 0.725 | 0.279 | 0.113 | 0.345 | |
| ID | OOD | 0.510 | 0.652 | 0.920 | 0.608 | 0.407 | 0.743 | 0.485 | 0.327 | 0.504 | |
| ID | OOD | 0.260 | 0.417 | 0.846 | 0.377 | 0.172 | 0.572 | 0.214 | 0.096 | 0.222 | |
| OOD | ID | 0.637 | 0.573 | 0.902 | 0.240 | 0.140 | 0.492 | 0.539 | 0.323 | 0.581 | |
| OOD | ID | 0.434 | 0.358 | 0.824 | −0.089 | −0.008 | 0.085 | 0.283 | 0.073 | 0.332 | |
| OOD | OOD | 0.432 | 0.602 | 0.937 | 0.369 | 0.251 | 0.555 | 0.495 | 0.277 | 0.515 | |
| OOD | OOD | 0.187 | 0.361 | 0.876 | 0.046 | 0.055 | 0.205 | 0.233 | 0.048 | 0.225 |
Table B2.
Time-Series Alignment and Preprocessing
This appendix defines the temporal construction shared across the three domains. Appendix D describes the data sources, state variables, and domain-specific splits.
| Condition | State variable | Original | Original | Original | Video FT | Video FT | Video FT | Time-JEPA | Time-JEPA | Time-JEPA |
| nRMSE | nRMSE | nRMSE | ||||||||
| Base translation speed | 0.459 | 0.210 | 0.907 | 0.461 | 0.212 | 0.906 | 0.529 | 0.279 | 0.867 | |
| Base angular speed | 0.465 | 0.216 | 0.793 | 0.474 | 0.224 | 0.789 | 0.596 | 0.352 | 0.721 | |
| Waist PC1 | 0.763 | 0.582 | 0.647 | 0.782 | 0.611 | 0.624 | 0.912 | 0.833 | 0.407 | |
| Waist PC2 | 0.803 | 0.644 | 0.608 | 0.813 | 0.661 | 0.593 | 0.899 | 0.807 | 0.449 | |
| Left arm position | 0.608 | 0.371 | 0.768 | 0.637 | 0.406 | 0.746 | 0.847 | 0.718 | 0.510 | |
| Left arm position | 0.800 | 0.640 | 0.567 | 0.814 | 0.663 | 0.548 | 0.929 | 0.863 | 0.349 | |
| Left arm position | 0.639 | 0.410 | 0.701 | 0.663 | 0.441 | 0.682 | 0.846 | 0.718 | 0.476 | |
| Right arm position | 0.709 | 0.502 | 0.710 | 0.735 | 0.539 | 0.684 | 0.889 | 0.791 | 0.456 | |
| Right arm position | 0.743 | 0.553 | 0.642 | 0.768 | 0.589 | 0.616 | 0.920 | 0.845 | 0.376 | |
| Right arm position | 0.665 | 0.445 | 0.714 | 0.688 | 0.476 | 0.693 | 0.860 | 0.742 | 0.475 | |
| Left end velocity | 0.426 | 0.186 | 0.913 | 0.486 | 0.241 | 0.882 | 0.854 | 0.728 | 0.528 | |
| Left end velocity | 0.455 | 0.207 | 0.873 | 0.527 | 0.277 | 0.834 | 0.880 | 0.772 | 0.468 | |
| Left end velocity | 0.370 | 0.133 | 0.925 | 0.419 | 0.171 | 0.904 | 0.826 | 0.680 | 0.557 | |
| Right end velocity | 0.596 | 0.360 | 0.781 | 0.647 | 0.420 | 0.744 | 0.910 | 0.828 | 0.405 | |
| Right end velocity | 0.563 | 0.324 | 0.809 | 0.624 | 0.392 | 0.769 | 0.906 | 0.821 | 0.417 | |
| Right end velocity | 0.530 | 0.275 | 0.836 | 0.567 | 0.318 | 0.811 | 0.868 | 0.754 | 0.483 | |
| Left gripper state | 0.718 | 0.519 | 0.693 | 0.731 | 0.537 | 0.679 | 0.878 | 0.771 | 0.480 | |
| Right gripper state | 0.651 | 0.432 | 0.732 | 0.670 | 0.458 | 0.714 | 0.869 | 0.754 | 0.485 | |
| Variable macro | 0.609 | 0.389 | 0.757 | 0.639 | 0.424 | 0.734 | 0.845 | 0.725 | 0.495 | |
| Base translation speed | 0.211 | 0.007 | 1.017 | 0.155 | −0.016 | 1.029 | 0.355 | 0.006 | 1.017 | |
| Base angular speed | 0.265 | −0.033 | 0.911 | 0.207 | −0.072 | 0.928 | 0.347 | −0.048 | 0.917 | |
| Waist PC1 | 0.511 | 0.145 | 0.927 | 0.506 | 0.081 | 0.960 | 0.540 | 0.073 | 0.968 | |
| Waist PC2 | 0.449 | 0.153 | 0.940 | 0.412 | 0.137 | 0.949 | 0.617 | −0.112 | 1.076 | |
| Left arm position | 0.319 | −0.084 | 1.009 | 0.324 | −0.109 | 1.021 | 0.420 | −0.292 | 1.087 | |
| Left arm position | 0.404 | 0.131 | 0.880 | 0.409 | 0.137 | 0.877 | 0.754 | 0.303 | 0.786 | |
| Left arm position | 0.163 | −0.004 | 0.916 | 0.144 | −0.047 | 0.935 | 0.244 | −0.063 | 0.943 | |
| Right arm position | 0.256 | −0.074 | 1.044 | 0.264 | 0.010 | 1.002 | 0.463 | −0.031 | 1.023 | |
| Right arm position | 0.259 | −0.012 | 0.969 | 0.274 | 0.029 | 0.949 | 0.638 | 0.321 | 0.791 | |
| Right arm position | 0.207 | 0.017 | 0.952 | 0.243 | 0.050 | 0.935 | 0.245 | −0.256 | 1.061 | |
| Left end velocity | 0.091 | −0.026 | 1.028 | 0.107 | −0.030 | 1.030 | 0.525 | 0.330 | 0.809 | |
| Left end velocity | 0.157 | 0.006 | 0.980 | 0.197 | −0.007 | 0.986 | 0.587 | 0.227 | 0.859 | |
| Left end velocity | 0.062 | −0.017 | 1.002 | 0.084 | −0.015 | 1.001 | 0.355 | 0.133 | 0.920 | |
| Right end velocity | 0.107 | −0.077 | 1.017 | 0.126 | −0.126 | 1.040 | 0.530 | 0.332 | 0.781 | |
| Right end velocity | 0.213 | 0.032 | 0.974 | 0.258 | 0.058 | 0.961 | 0.596 | 0.394 | 0.750 | |
| Right end velocity | 0.102 | −0.028 | 0.996 | 0.109 | −0.041 | 1.003 | 0.462 | 0.175 | 0.886 | |
| Left gripper state | 0.275 | 0.055 | 0.980 | 0.343 | 0.070 | 0.972 | 0.604 | 0.254 | 0.862 | |
| Right gripper state | 0.199 | −0.151 | 1.056 | 0.220 | −0.125 | 1.044 | 0.577 | −0.209 | 1.074 | |
| Variable macro | 0.236 | 0.002 | 0.978 | 0.243 | −0.001 | 0.979 | 0.492 | 0.085 | 0.923 |
Table B3. robot manipulation: variables.
| Condition | State variable | Original | Original | Original nRMSE | Video FT | Video FT | Video FT nRMSE | Time-JEPA | Time-JEPA | Time-JEPA nRMSE |
| Left joint-position norm | 0.764 | 0.583 | 0.616 | 0.775 | 0.600 | 0.603 | 0.856 | 0.732 | 0.494 | |
| Right joint-position norm | 0.715 | 0.511 | 0.685 | 0.736 | 0.541 | 0.664 | 0.850 | 0.722 | 0.517 | |
| Left joint-velocity norm | 0.723 | 0.521 | 0.705 | 0.756 | 0.569 | 0.669 | 0.907 | 0.821 | 0.432 | |
| Right joint-velocity norm | 0.783 | 0.613 | 0.610 | 0.806 | 0.649 | 0.581 | 0.920 | 0.845 | 0.386 | |
| Left joint-effort norm | 0.533 | 0.283 | 0.853 | 0.544 | 0.294 | 0.846 | 0.649 | 0.420 | 0.766 | |
| Right joint-effort norm | 0.518 | 0.268 | 0.923 | 0.534 | 0.284 | 0.913 | 0.650 | 0.422 | 0.820 | |
| Left wrench-force norm | 0.515 | 0.255 | 0.913 | 0.518 | 0.254 | 0.913 | 0.553 | 0.293 | 0.889 | |
| Right wrench-force norm | 0.505 | 0.252 | 1.043 | 0.509 | 0.256 | 1.040 | 0.545 | 0.291 | 1.015 | |
| Variable macro | 0.632 | 0.411 | 0.793 | 0.647 | 0.431 | 0.778 | 0.741 | 0.568 | 0.665 | |
| Left joint-position norm | 0.458 | 0.048 | 0.931 | 0.515 | 0.087 | 0.912 | 0.545 | −0.036 | 0.971 | |
| Right joint-position norm | 0.375 | −0.048 | 1.004 | 0.442 | 0.108 | 0.927 | 0.668 | 0.365 | 0.782 | |
| Left joint-velocity norm | 0.407 | 0.146 | 0.944 | 0.471 | 0.208 | 0.909 | 0.886 | 0.782 | 0.477 | |
| Right joint-velocity norm | 0.591 | 0.336 | 0.801 | 0.605 | 0.356 | 0.789 | 0.858 | 0.666 | 0.568 | |
| Left joint-effort norm | 0.284 | 0.031 | 0.991 | 0.321 | 0.052 | 0.980 | 0.392 | −0.151 | 1.080 | |
| Right joint-effort norm | 0.263 | 0.060 | 1.046 | 0.289 | 0.082 | 1.034 | 0.439 | 0.055 | 1.049 | |
| Left wrench-force norm | 0.327 | 0.103 | 1.002 | 0.307 | 0.078 | 1.015 | 0.396 | 0.064 | 1.023 | |
| Right wrench-force norm | 0.280 | 0.067 | 1.165 | 0.262 | 0.050 | 1.175 | 0.254 | −0.106 | 1.268 | |
| Variable macro | 0.373 | 0.093 | 0.985 | 0.402 | 0.127 | 0.968 | 0.555 | 0.205 | 0.902 |
Table B4. Table B4: robot manipulation: variables.
| Condition | State variable | Original | Original | Original nRMSE | Video FT | Video FT | Video FT nRMSE | Time-JEPA | Time-JEPA | Time-JEPA nRMSE |
| Longitudinal velocity | 0.972 | 0.942 | 0.213 | 0.975 | 0.949 | 0.200 | 0.990 | 0.979 | 0.127 | |
| Longitudinal acceleration | 0.477 | 0.225 | 0.886 | 0.510 | 0.256 | 0.868 | 0.771 | 0.594 | 0.642 | |
| Yaw rate | 0.963 | 0.926 | 0.280 | 0.967 | 0.934 | 0.266 | 0.986 | 0.973 | 0.170 | |
| Variable macro | 0.804 | 0.698 | 0.460 | 0.817 | 0.713 | 0.445 | 0.916 | 0.849 | 0.313 | |
| Longitudinal velocity | 0.961 | 0.919 | 0.261 | 0.966 | 0.926 | 0.249 | 0.986 | 0.972 | 0.152 | |
| Longitudinal acceleration | 0.488 | 0.236 | 0.848 | 0.515 | 0.262 | 0.833 | 0.740 | 0.542 | 0.656 | |
| Yaw rate | 0.950 | 0.900 | 0.351 | 0.954 | 0.908 | 0.337 | 0.980 | 0.958 | 0.228 | |
| Variable macro | 0.800 | 0.685 | 0.487 | 0.812 | 0.699 | 0.473 | 0.902 | 0.824 | 0.346 |
Table B5. Table B5: autonomous driving: variables.
| Condition | State variable | Original | Original | Original nRMSE | Video FT | Video FT | Video FT nRMSE | Time-JEPA | Time-JEPA | Time-JEPA nRMSE |
| Steering angle | 0.848 | 0.717 | 0.586 | 0.853 | 0.725 | 0.578 | 0.884 | 0.781 | 0.516 | |
| Lateral velocity | 0.927 | 0.859 | 0.390 | 0.932 | 0.867 | 0.378 | 0.951 | 0.904 | 0.320 | |
| Lateral acceleration | 0.861 | 0.736 | 0.479 | 0.872 | 0.756 | 0.460 | 0.925 | 0.853 | 0.357 | |
| Variable macro | 0.879 | 0.771 | 0.485 | 0.885 | 0.783 | 0.472 | 0.920 | 0.846 | 0.398 | |
| Steering angle | 0.887 | 0.786 | 0.423 | 0.892 | 0.795 | 0.414 | 0.924 | 0.854 | 0.350 | |
| Lateral velocity | 0.928 | 0.860 | 0.390 | 0.932 | 0.868 | 0.377 | 0.954 | 0.910 | 0.312 | |
| Lateral acceleration | 0.868 | 0.751 | 0.521 | 0.880 | 0.771 | 0.499 | 0.932 | 0.865 | 0.384 | |
| Variable macro | 0.894 | 0.799 | 0.445 | 0.901 | 0.812 | 0.430 | 0.937 | 0.876 | 0.349 |
Table B6. Table B6: autonomous driving: variables.
| Condition | State variable | Original | Original | Original nRMSE | Video FT | Video FT | Video FT nRMSE | Time-JEPA | Time-JEPA | Time-JEPA nRMSE |
| ID | Pelvis speed | 0.582 | 0.334 | 0.652 | 0.589 | 0.343 | 0.648 | 0.696 | 0.472 | 0.581 |
| ID | Left wrist relative speed | 0.518 | 0.259 | 0.682 | 0.519 | 0.260 | 0.682 | 0.559 | 0.306 | 0.660 |
| ID | Right wrist relative speed | 0.519 | 0.267 | 0.613 | 0.522 | 0.269 | 0.613 | 0.557 | 0.304 | 0.598 |
| ID | Left ankle relative speed | 0.256 | 0.058 | 0.736 | 0.257 | 0.058 | 0.736 | 0.323 | 0.095 | 0.721 |
| ID | Right ankle relative speed | 0.437 | 0.167 | 0.404 | 0.442 | 0.168 | 0.404 | 0.534 | 0.234 | 0.388 |
| ID | Left elbow flexion | 0.328 | 0.057 | 1.017 | 0.329 | 0.061 | 1.015 | 0.465 | 0.194 | 0.940 |
| ID | Right elbow flexion | 0.436 | 0.122 | 0.988 | 0.436 | 0.126 | 0.985 | 0.557 | 0.294 | 0.886 |
| ID | Left knee flexion | 0.743 | 0.493 | 0.744 | 0.747 | 0.501 | 0.738 | 0.829 | 0.666 | 0.604 |
| ID | Right knee flexion | 0.681 | 0.290 | 0.858 | 0.684 | 0.297 | 0.853 | 0.783 | 0.544 | 0.687 |
| Variable macro | 0.500 | 0.228 | 0.744 | 0.503 | 0.231 | 0.742 | 0.589 | 0.345 | 0.674 | |
| OOD | Pelvis speed | 0.558 | 0.303 | 0.667 | 0.564 | 0.309 | 0.665 | 0.689 | 0.461 | 0.587 |
| OOD | Left wrist relative speed | 0.483 | 0.229 | 0.696 | 0.486 | 0.232 | 0.694 | 0.539 | 0.287 | 0.669 |
| OOD | Right wrist relative speed | 0.487 | 0.232 | 0.628 | 0.490 | 0.236 | 0.627 | 0.548 | 0.296 | 0.601 |
| OOD | Left ankle relative speed | 0.258 | 0.054 | 0.737 | 0.262 | 0.056 | 0.737 | 0.320 | 0.085 | 0.725 |
| OOD | Right ankle relative speed | 0.436 | 0.162 | 0.406 | 0.442 | 0.167 | 0.405 | 0.549 | 0.254 | 0.383 |
| OOD | Left elbow flexion | 0.341 | 0.078 | 1.006 | 0.353 | 0.095 | 0.997 | 0.468 | 0.200 | 0.937 |
| OOD | Right elbow flexion | 0.424 | 0.127 | 0.985 | 0.432 | 0.140 | 0.978 | 0.562 | 0.307 | 0.878 |
| OOD | Left knee flexion | 0.695 | 0.378 | 0.825 | 0.702 | 0.400 | 0.810 | 0.799 | 0.606 | 0.657 |
| OOD | Right knee flexion | 0.638 | 0.140 | 0.944 | 0.639 | 0.158 | 0.934 | 0.757 | 0.489 | 0.728 |
| Variable macro | 0.480 | 0.189 | 0.766 | 0.486 | 0.199 | 0.761 | 0.581 | 0.332 | 0.685 |
Table B7. human motion: ID variables.
| Condition | State variable | Original | Original | Original nRMSE | Video FT | Video FT | Video FT nRMSE | Time-JEPA | Time-JEPA | Time-JEPA nRMSE |
| ID | Inter-wrist distance | 0.573 | 0.316 | 0.893 | 0.575 | 0.320 | 0.891 | 0.643 | 0.400 | 0.836 |
| ID | Left wrist–shoulder distance | 0.287 | 0.000 | 0.669 | 0.290 | 0.000 | 0.669 | 0.385 | 0.074 | 0.644 |
| ID | Right wrist–shoulder distance | 0.472 | 0.177 | 0.635 | 0.471 | 0.176 | 0.635 | 0.533 | 0.262 | 0.601 |
| ID | Inter-ankle distance | 0.223 | −0.109 | 0.370 | 0.215 | −0.121 | 0.372 | 0.247 | −0.089 | 0.367 |
| ID | Pelvis support height | 0.614 | 0.277 | 0.451 | 0.621 | 0.289 | 0.447 | 0.710 | 0.462 | 0.389 |
| Variable macro | 0.434 | 0.132 | 0.603 | 0.434 | 0.133 | 0.603 | 0.504 | 0.222 | 0.567 | |
| OOD | Inter-wrist distance | 0.571 | 0.318 | 0.891 | 0.573 | 0.320 | 0.890 | 0.640 | 0.396 | 0.839 |
| OOD | Left wrist–shoulder distance | 0.361 | 0.086 | 0.640 | 0.365 | 0.091 | 0.638 | 0.428 | 0.129 | 0.624 |
| OOD | Right wrist–shoulder distance | 0.492 | 0.219 | 0.618 | 0.494 | 0.220 | 0.618 | 0.548 | 0.277 | 0.595 |
| OOD | Inter-ankle distance | 0.232 | −0.162 | 0.379 | 0.228 | −0.150 | 0.377 | 0.258 | −0.103 | 0.369 |
| OOD | Pelvis support height | 0.593 | 0.173 | 0.483 | 0.601 | 0.194 | 0.477 | 0.704 | 0.426 | 0.402 |
| Variable macro | 0.450 | 0.127 | 0.602 | 0.452 | 0.135 | 0.600 | 0.515 | 0.225 | 0.566 |
Table B8. human motion: OOD variables.
Common Temporal Construction
The main V-JEPA experiments sample 64 RGB frames at 5 FPS. Each video tubelet contains two sampled frames, producing state values at 32 temporal positions. For scalar dimension , let denote the physical-state value at sampled frame and its validity indicator. For tubelet , the aligned state value is
We mask each tubelet–variable entry that lacks valid frames and compute training-set means and standard deviations from valid values. We standardize each available state value as and retain the validity mask through normalization and the Smooth-L1 objective. Current-state probes on frozen encoders predict the 32 aligned time steps. Appendix § 18 defines the future-state labels.
Data Sources, State Variables, and Splits
This appendix defines the data sources, physical state variables, and split construction for § 4. We assign disjoint split roles to encoder fine-tuning, probe training, probe validation, and testing. For robot manipulation and human motion, we test the same physical windows through ID and OOD cameras. We estimate normalization statistics from the relevant training split and track validity separately for each state variable.
| autonomous driving | Fine-tuning: 6,305 clips. Probe train: 1,349 clips. Probe validation: 449 clips. ID test: 900 clips. OOD test: 521 clips from date-disjoint caption-defined stable rain. |
| robot manipulation | Fine-tuning: 15,000 windows. Probe train: 1,5003. Probe validation: 5003. ID test: 1,0003. OOD test: 1,0002 from held-out left/right fisheye cameras. |
| human motion | Fine-tuning: 7,000 windows. Probe train: 1,500 windows. Probe validation: 500 windows. ID test: 1,0003. OOD test: the same 1,000 test windows from held-out exocentric view03. |
Table D1. Data roles and evaluated views. denotes physical windows with views each. For robot manipulation, we expand probe splits over views. For human motion, we sample one seen view per training access, fix one per validation window, and evaluate all three seen views for ID testing. Each autonomous driving clip provides one view.
CoVLA Data Source
Source data. CoVLA [2] contains 10,000 30-s forward-facing driving videos with temporally aligned CAN and inertial states, trajectories, and scene descriptions.
https://huggingface.co/datasets/turing-motors/CoVLA-Dataset
We use RGB video, vehicle states, and trajectories, and construct the weather split from captions.
State-variable selection. The three ID variables cover longitudinal speed, longitudinal acceleration, and turning motion. We use calibrated-frame angular velocity for yaw because it agrees with heading change. We reserve steering angle, lateral velocity, and lateral acceleration as OOD variables and use the future trajectory as an independent reference for reconstruction.
Split and weather criterion. We separate CoVLA split roles at both video and date levels. The OOD split uses caption-defined rain: at least eight of the ten caption frames 0, 60, , 540 must describe rainy weather. This criterion yields the 521-clip OOD test set.
Alignment. CoVLA records video at 20 FPS. Sampling every fourth frame gives 64 frames at 5 FPS, spanning 12.6 s. We map frame indices to timestamped vehicle-state records before tubelet averaging and use the sampled timestamps for trajectory integration.
| ID (3 variables) |
| Longitudinal ego velocity (m/s) |
| Longitudinal ego acceleration (m/s) |
| Calibrated-frame yaw angular velocity (rad/s) |
Table D2. autonomous driving state variables. Variable groups follow Section 4.2. Both groups use supervised probes on frozen encoders.
| OOD (3 variables) |
| Steering-wheel angle (control quantity, degree) |
| Calibrated-frame lateral velocity (m/s) |
| Calibrated-frame lateral acceleration (m/s) |
Table D2 (PDF p. 20). autonomous driving state variables. Variable groups follow Section 4.2. Both groups use supervised probes on frozen encoders.
AgiBot Data Source
Source data. AgiBot [8] provides synchronized multi-camera video and full-body robot state.
https://huggingface.co/datasets/agibot-world/AgiBotWorld2026
The G2 state stream includes base and waist pose, bilateral joint position, velocity and effort, end-effector pose and wrench, and gripper state. The encoder receives selected RGB views.
State-variable selection. The 18 ID variables cover base motion, torso configuration, bilateral end-effector position and signed velocity, and gripper state. Two principal components summarize the 5D waist state. Signed velocity preserves the direction needed for reach-rate reconstruction. The eight OOD variables summarize bilateral arm configuration, joint motion, effort, and contact force.
Views and leakage control. The seen views comprise one overhead and two hand-mounted cameras. OOD uses two held-out fisheye cameras. We assign split roles by a camera-agnostic episode/window key before expanding views, keeping every recording of a physical interval in one role. ID and OOD test the same 1,000 physical windows.
State alignment and derived quantities. We align video timestamps to the LeRobot state timeline within 0.05 s before tubelet averaging. We fit waist PCA on the fine-tuning split and retain its first two axes. End-effector velocities use finite differences of arm position on the native state timeline.
| ID (18 variables) |
| Planar base translation-speed magnitude (1D, m/s) |
| Base angular-speed magnitude (1D, rad/s) |
| First two frozen PCA scores of the 5D waist configuration (2D, PCA score) |
| Signed left/right end-effector position (6D, m) |
| Signed left/right end-effector velocity in the recorded frame (6D, m/s) |
| Bilateral gripper opening state (2D, native scalar) |
Table D3. robot manipulation state variables. Variable groups follow Section 4.2. Parentheses give the number of scalar dimensions in each bilateral or vector group.
| OOD (8 variables) |
| L2 norm of each arm’s 7D joint configuration (2D, rad) |
| L2 norm of each arm’s joint velocity (2D, rad/s) |
| L2 norm of bilateral joint effort (2D, native effort) |
| Bilateral end-effector force magnitude (2D, native force) |
Table D3 (PDF p. 20). robot manipulation state variables. Variable groups follow Section 4.2. Parentheses give the number of scalar dimensions in each bilateral or vector group.
EgoExo4D Data Source
Source data. EgoExo4D [12] provides synchronized egocentric and exocentric recordings of skilled activities.
https://docs.ego-exo4d-data.org/download/
We use exocentric RGB video and 3D body-pose annotations.
Variables and splits. The panel captures whole-body translation, local limb motion, and joint articulation. The panel covers bimanual coordination, arm extension, stance width, and support height. Fine-tuning and probing use exocentric view01, view02, and view04; uses held-out exocentric view03. Split roles are isolated at the take, participant, and capture levels, and both condition settings evaluate the same 1,000 physical test windows.
Temporal processing. We apply fixed smoothing and temporal alignment, retain valid measurements with at least two supporting views, and average them within each two-frame tubelet. Coordinates and distances use meters, speeds use m/s, and flexion angles use radians.
| (9 variables) |
| Pelvis speed: speed of the midpoint between the left and right hips (1D, m/s) |
| Left/right wrist relative speed: wrist speed after subtracting pelvis translation (2D, m/s) |
| Left/right ankle relative speed: ankle speed after subtracting pelvis translation (2D, m/s) |
| Left/right elbow flexion: interior shoulder–elbow–wrist angle (2D, rad) |
| Left/right knee flexion: interior hip–knee–ankle angle (2D, rad) |
| (5 variables) |
| Inter-wrist distance: Euclidean distance between the two wrists (1D, m) |
| Left/right wrist–shoulder distance: Euclidean shoulder-to-wrist endpoint distance (2D, m) |
| Inter-ankle distance: Euclidean distance between the two ankles (1D, m) |
| Pelvis support height: pelvis height relative to the two-foot support reference (1D, m) |
Table D4. human motion state variables. Variable groups follow § 4.2.
Kinematic Reconstruction
Section 6 reports one primary kinematic-reconstruction error for each domain. This appendix explains each domain-specific reconstruction and provides finer-grained results. For each encoder, we train separate probes on frozen video features to predict the physical quantities required by a fixed law. We use these predictions to reconstruct a trajectory endpoint, reach rate, or limb-endpoint distance, then compare the result with independently constructed ground truth. For autonomous driving and human motion, another probe predicts the same endpoint or distance directly. The tables label this error as Direct. As an additional diagnostic, we compare each reconstruction with fixed alternatives: incorrect physical relations for autonomous driving and human motion, and cross-arm joint-state–velocity pairings for robot manipulation. The score records how often the correct relation or same-arm pairing gives the lower error. Applying the same computation to ground-truth inputs reveals error introduced by integration, calibration, or pose annotations. Training and validation data determine the coordinate conventions, formulas, thresholds, and alternatives before test evaluation. The tables report results by trajectory horizon, camera, or limb. We select each probe by validation loss and report the mean and sample standard deviation across five probe seeds (0–4).
Tables E1–E3 give single-domain diagnostics. Table 4 reports the multi-domain comparison, and Table F4 compares single-domain and multi-domain Time-JEPA.
autonomous driving: Integrated Trajectory Reconstruction
Using probe-training ground truth, The resulting coordinate convention is
Starting from and , the measured interval gives
where is the planar rotation matrix. Recorded trajectory indices 20, 40, and 59 correspond to 1.00, 2.00, and 2.95 s. A separate 2D probe predicts each direct endpoint independently of the three state probes used for integration.
For law discrimination, the positive candidate uses the frozen convention. The negative pool contains: reversed yaw sign, reversed lateral-velocity sign, a one-token temporal offset, state sequences from another video, and an endpoint evaluated at the wrong horizon. If and are the positive and negative endpoint errors, respectively, the reported score is
Table E1: autonomous driving trajectory reconstruction by horizon. Direct and integrated errors use endpoint MAE in meters. AUROC compares the correct integration law with the fixed alternatives. Values give mean sample standard deviation across five probe seeds. Bold marks the best encoder mean.
| Split | Horizon | Encoder | Direct | Integrated | AUROC |
| ID | 1.00 s | Original | 2.226 0.092 | 2.199 0.057 | 0.642 0.002 |
| ID | 1.00 s | Video FT | 2.124 0.108 | 2.083 0.064 | 0.649 0.003 |
| ID | 1.00 s | Time-JEPA | 1.408 0.096 | 1.242 0.050 | 0.707 0.004 |
| ID | 2.00 s | Original | 4.728 0.097 | 4.436 0.116 | 0.636 0.004 |
| ID | 2.00 s | Video FT | 4.528 0.098 | 4.194 0.129 | 0.647 0.004 |
| ID | 2.00 s | Time-JEPA | 3.000 0.126 | 2.467 0.097 | 0.724 0.004 |
| ID | 2.95 s | Original | 6.994 0.128 | 6.634 0.172 | 0.632 0.006 |
| ID | 2.95 s | Video FT | 6.656 0.120 | 6.262 0.192 | 0.645 0.007 |
| ID | 2.95 s | Time-JEPA | 4.407 0.154 | 3.648 0.139 | 0.732 0.004 |
| OOD | 1.00 s | Original | 2.424 0.110 | 2.394 0.101 | 0.635 0.004 |
| OOD | 1.00 s | Video FT | 2.317 0.081 | 2.248 0.094 | 0.641 0.004 |
| OOD | 1.00 s | Time-JEPA | 1.645 0.206 | 1.428 0.156 | 0.687 0.009 |
| OOD | 2.00 s | Original | 4.983 0.398 | 4.836 0.199 | 0.628 0.004 |
| OOD | 2.00 s | Video FT | 4.787 0.377 | 4.532 0.184 | 0.637 0.004 |
| OOD | 2.00 s | Time-JEPA | 3.306 0.643 | 2.841 0.305 | 0.705 0.009 |
| OOD | 2.95 s | Original | 7.651 0.701 | 7.256 0.296 | 0.614 0.009 |
| OOD | 2.95 s | Video FT | 7.206 0.608 | 6.789 0.274 | 0.627 0.009 |
| OOD | 2.95 s | Time-JEPA | 5.152 1.047 | 4.211 0.442 | 0.707 0.010 |
Table E1.
Trapezoidal integration of ground-truth velocity and yaw-rate sequences gives deterministic endpoint MAEs of 0.321/0.639/0.953 m at 1.00/2.00/2.95 s under ID, and 0.273/0.526/0.757 m under rainy OOD.
Time-JEPA improves direct error, integrated-trajectory error, and law AUROC over the video-fine-tuned control at every horizon under ID and rainy OOD. Errors increase with horizon for every row.
robot manipulation: Reach-Rate Reconstruction
For arm , the official URDF maps the independently decoded 7D joint state to the hand position. We estimate rigid calibration and shoulder points from the fine-tuning split and fix them for evaluation:
| Split | Camera | Encoder | Left | Right | Pair rate |
| Top head | Original | 4.130 0.022 | 7.209 0.019 | 0.502 0.018 | |
| Top head | Video FT | 4.094 0.016 | 7.025 0.026 | 0.492 0.016 | |
| Top head | Time-JEPA | 3.137 0.045 | 3.745 0.043 | 0.553 0.007 | |
| Left hand | Original | 3.805 0.012 | 7.397 0.022 | 0.516 0.017 | |
| Left hand | Video FT | 3.751 0.018 | 7.252 0.017 | 0.541 0.030 | |
| Left hand | Time-JEPA | 3.010 0.027 | 3.863 0.032 | 0.616 0.019 | |
| Right hand | Original | 4.167 0.029 | 6.432 0.015 | 0.578 0.031 | |
| Right hand | Video FT | 4.131 0.029 | 6.312 0.016 | 0.584 0.017 | |
| Right hand | Time-JEPA | 2.925 0.032 | 4.047 0.023 | 0.591 0.026 | |
| Left fisheye | Original | 4.228 0.040 | 7.568 0.051 | 0.455 0.013 | |
| Left fisheye | Video FT | 4.217 0.043 | 7.532 0.051 | 0.491 0.023 | |
| Left fisheye | Time-JEPA | 3.254 0.095 | 7.000 0.032 | 0.550 0.015 | |
| Right fisheye | Original | 4.241 0.042 | 7.569 0.059 | 0.489 0.010 | |
| Right fisheye | Video FT | 4.259 0.037 | 7.415 0.057 | 0.532 0.014 | |
| Right fisheye | Time-JEPA | 4.183 0.027 | 4.402 0.074 | 0.588 0.024 |
Table E2. robot manipulation reach-rate reconstruction by camera. Left/right columns give MAE in cm/s. Pair rate averages the two arms per camera. Values give mean sample standard deviation across five probe seeds. Bold marks the best encoder mean per camera and metric.
We compute this direction only when the predicted shoulder-to-hand distance exceeds m. Before testing, we use the probe-training and validation splits to check the calibrated joint-to-hand mapping, the reach rate computed from ground-truth inputs, and the number of valid samples. These checks fix the validity threshold and the timestamp-based calculation of ground-truth reach rate. A separate probe predicts the hand velocity . Projecting this velocity onto the shoulder-to-hand direction gives the signed reach rate:
We compute the ground-truth signed reach rate from raw shoulder-to-hand distances and source timestamps. For interior samples, we use the distance change between the preceding and following samples; at each sequence boundary, we use the nearest two samples.
The pairing diagnostic holds velocity fixed, substitutes the opposite-arm joint state, and reports how often the correct pairing is closer to ground truth (half credit for ties).
The left-fisheye/right-arm error remains comparatively high, while Time-JEPA improves the macro errors and correct-pairing rate reported in § 6. Passing ground-truth joint angles and endpoint velocities through the same calibrated projection gives deterministic reference errors of 0.063 cm/s for the left arm and 0.084 cm/s for the right arm on both evaluated camera families.
human motion: Cosine-Law Distance Reconstruction
For elbows, denote upper-arm length, forearm length, and shoulder–wrist distance. For knees they denote thigh length, shin length, and hip–ankle distance. Ground-truth checks on the probe-training and validation splits fix the internal-angle convention, clipping, morphology rule, nonnegative square-root guard, and three alternatives after verifying coverage, ground-truth-input error, law AUROC, and the correct-law margin. The distance reconstruction is
The alternatives use , the opposite-side limb angle, or a one-token temporal shift. Table E3 reports AUROC averaged over all activities.
Table E3: human motion cosine-law distance reconstruction. Direct and cosine-law errors use MAE in cm. AUROC compares the correct relation with three fixed alternatives. Values give mean sample standard deviation across five probe seeds. Bold marks the best encoder mean for each limb, split, and metric.
| Limb | Encoder | Direct | Cosine | AUROC | Direct | Cosine | AUROC |
| Elbow L | Original | 7.017 0.089 | 6.657 0.103 | 0.561 0.004 | 7.111 0.110 | 6.868 0.178 | 0.554 0.006 |
| Elbow L | Video FT | 7.028 0.091 | 6.671 0.110 | 0.562 0.004 | 7.108 0.113 | 6.845 0.189 | 0.556 0.006 |
| Elbow L | Time-JEPA | 6.759 0.091 | 6.404 0.103 | 0.570 0.006 | 6.790 0.136 | 6.527 0.189 | 0.565 0.006 |
| Elbow R | Original | 6.786 0.025 | 6.597 0.020 | 0.568 0.002 | 6.880 0.117 | 6.749 0.066 | 0.564 0.004 |
| Elbow R | Video FT | 6.799 0.037 | 6.628 0.023 | 0.567 0.002 | 6.884 0.121 | 6.771 0.072 | 0.563 0.004 |
| Elbow R | Time-JEPA | 6.482 0.033 | 6.360 0.045 | 0.573 0.003 | 6.501 0.125 | 6.420 0.059 | 0.570 0.003 |
| Knee L | Original | 10.162 0.326 | 7.617 0.180 | 0.657 0.007 | 10.802 0.267 | 8.142 0.348 | 0.657 0.007 |
| Knee L | Video FT | 10.155 0.325 | 7.570 0.206 | 0.657 0.009 | 10.763 0.290 | 8.070 0.371 | 0.657 0.009 |
| Knee L | Time-JEPA | 9.034 0.291 | 6.590 0.170 | 0.655 0.007 | 9.515 0.318 | 6.865 0.275 | 0.659 0.008 |
| Knee R | Original | 9.369 0.499 | 6.636 0.280 | 0.641 0.008 | 10.047 0.538 | 7.156 0.528 | 0.637 0.008 |
| Knee R | Video FT | 9.350 0.508 | 6.582 0.321 | 0.642 0.010 | 10.010 0.554 | 7.102 0.531 | 0.638 0.009 |
| Knee R | Time-JEPA | 8.209 0.462 | 5.566 0.226 | 0.649 0.007 | 8.721 0.450 | 5.879 0.369 | 0.642 0.008 |
Table E3.
Ground-truth angles give deterministic ground-truth-input errors of 1.975/2.036 cm for left/right elbows and 3.221/2.153 cm for left/right knees. and share these references because they show the same windows from different cameras.
Multi-Domain Training
Multi-domain training shares one online encoder, EMA target encoder, and JEPA predictor across domains. Each domain retains its own variables, train-only normalization statistics, pointwise auxiliary head, loss weight, validity mask, and warmup counter. The video-fine-tuned control uses the same synchronized multi-domain schedule and optimizes .
Multi-Domain Training Schedule
After distributed sharding, each domain contributes the same number of complete batches as in its corresponding single-domain loader. All ranks select the same domain and its auxiliary head at each optimizer step. Table F1 gives the exact accounting for eight GPUs and batch size eight per GPU.
Table F1: Per-domain schedule quotas. Each entry reports synchronized optimizer steps per epoch for the corresponding domain loader.
| Domain | Reference loader | Shared schedule |
| autonomous driving | 98 steps / epoch | 98 steps / epoch |
| robot manipulation | 234 steps / epoch | 234 steps / epoch |
| human motion | 109 steps / epoch | 109 steps / epoch |
Table F1.
Matched Probes and Multi-Domain Results
Within each domain and panel, we hold the split, variable definitions, probe architecture, optimizer, seed, normalization, and aggregation fixed. We change only the frozen encoder.
Table F2 gives the exact values underlying the main-text comparison in Figure 3.
| Condition | Variables | Metric | autonomous driving Single | autonomous driving Multi | autonomous driving | robot manipulation Single | robot manipulation Multi | robot manipulation | human motion Single | human motion Multi | human motion |
| ID | ID | 0.916 | 0.988 | +0.072 | 0.845 | 0.912 | +0.066 | 0.589 | 0.698 | +0.109 | |
| ID | ID | 0.849 | 0.976 | +0.127 | 0.725 | 0.840 | +0.115 | 0.345 | 0.506 | +0.161 | |
| ID | OOD | 0.920 | 0.943 | +0.023 | 0.741 | 0.781 | +0.040 | 0.504 | 0.669 | +0.165 | |
| ID | OOD | 0.846 | 0.890 | +0.044 | 0.568 | 0.631 | +0.062 | 0.222 | 0.456 | +0.235 | |
| OOD | ID | 0.902 | 0.985 | +0.083 | 0.492 | 0.583 | +0.091 | 0.581 | 0.702 | +0.121 | |
| OOD | ID | 0.824 | 0.970 | +0.146 | 0.085 | 0.139 | +0.054 | 0.332 | 0.513 | +0.181 | |
| OOD | OOD | 0.937 | 0.961 | +0.025 | 0.555 | 0.609 | +0.054 | 0.515 | 0.672 | +0.156 | |
| OOD | OOD | 0.876 | 0.923 | +0.047 | 0.205 | 0.267 | +0.063 | 0.225 | 0.456 | +0.231 |
Table F2. Single-domain and multi-domain Time-JEPA. Single and Multi denote the corresponding Time-JEPA encoders. We compute changes before rounding and retain the matched supervised probes and variable/view aggregation from Table 1. Bold marks the higher score.
Across all four human motion panels, Pearson and increase from human motion only to autonomous driving + human motion and again to multi-domain Time-JEPA. For under , Pearson follows , and follows . The other three panels show the same monotonic direction in Figure F1.
Figure F1. Paired domain-addition trend in human motion. Connected three-point plots trace the paired sequence trained with human motion only, autonomous driving + human motion, and all three domains. Dark blue reports Pearson and orange reports . Point labels give the exact scores for all four variable–condition panels.
Single- vs. Multi-Domain Time-JEPA for Future-State Prediction
We compare single-domain and multi-domain Time-JEPA using the five-horizon probes from Appendix G. We keep the splits, variables, probe architecture, optimization, normalization, and probe seed fixed and change the frozen encoder. Table F3 reports all domain–variable–condition panels.
| Condition | Variables | Metric | autonomous driving Single | autonomous driving Multi | robot manipulation Single | robot manipulation Multi | human motion Single | human motion Multi |
| ID | ID | nRMSE | 0.485 | 0.349 | 0.647 | 0.570 | 0.999 | 0.913 |
| ID | ID | 0.719 | 0.851 | 0.506 | 0.587 | 0.244 | 0.375 | |
| ID | OOD | nRMSE | 0.560 | 0.488 | 0.771 | 0.722 | 0.978 | 0.894 |
| ID | OOD | 0.667 | 0.748 | 0.379 | 0.444 | 0.190 | 0.321 | |
| OOD | ID | nRMSE | 0.460 | 0.333 | 0.960 | 0.952 | 1.010 | 0.902 |
| OOD | ID | 0.680 | 0.812 | 0.008 | 0.006 | 0.226 | 0.391 | |
| OOD | OOD | nRMSE | 0.529 | 0.449 | 0.951 | 0.964 | 0.975 | 0.888 |
| OOD | OOD | 0.604 | 0.711 | 0.047 | -0.003 | 0.195 | 0.330 |
Table F3. Single-domain and multi-domain future-state prediction. Single and Multi denote Time-JEPA encoders. We average the five horizons from 0.2 to 1.0 s equally and use the variable/view aggregation from Appendix G. Each encoder uses one probe run per variable group. Bold marks the better unrounded score.
Multi-domain training improves both metrics in all six ID panels and in the autonomous driving and human motion OOD panels. For robot manipulation under OOD, it lowers ID nRMSE but also lowers , and the single-domain encoder performs better on both OOD metrics. The corresponding horizon-macro values are 0.960 → 0.952 and 0.008 → 0.006 for nRMSE and on ID, and 0.951 → 0.964 and 0.047 → −0.003 on OOD. Across the 24 displayed nRMSE and entries, multi-domain training is better in 21; the three reversals are these robot-manipulation OOD entries. Using the variable-count weights from Table 3, multi-domain training improves both aggregate metrics for both variable groups under both condition settings.
Single- vs. Multi-Domain Time-JEPA for Kinematic Reconstruction
We apply the reconstruction rules from Appendix E to matched probes on the single-domain and multi-domain Time-JEPA encoders. We keep the probe settings, evaluation windows, physical relations, and aggregation fixed across each pair. Multi-domain Time-JEPA lowers the primary error in all six panels (Table F4). These reconstruction gains and the aggregate prediction gains support our use of the multi-domain encoder for further physical evaluations.
| Condition | Domain | Metric ↓ | Single | Multi |
| ID | autonomous driving | Trajectory MAE (m) | 3.080 ± 0.114 | 1.795 ± 0.027 |
| robot manipulation | Reach-rate MAE (cm/s) | 3.454 ± 0.016 | 2.290 ± 0.006 | |
| human motion | Distance MAE (cm) | 6.230 ± 0.080 | 4.619 ± 0.065 | |
| OOD | autonomous driving | Trajectory MAE (m) | 3.572 ± 0.312 | 1.858 ± 0.144 |
| robot manipulation | Reach-rate MAE (cm/s) | 4.710 ± 0.025 | 4.171 ± 0.046 | |
| human motion | Distance MAE (cm) | 6.423 ± 0.129 | 4.557 ± 0.053 |
Table F4. Single-domain and multi-domain kinematic reconstruction. Single and Multi denote Time-JEPA encoders. Entries give mean ± sample standard deviation across five matched probe seeds. We average trajectory error over three horizons, reach-rate error over both arms, and distance error over four limbs within each seed. Bold marks the lower mean.
Future-State Prediction
Five-Horizon Protocol
Let be the final observed timestamp of the 64-frame, 5-FPS clip. The probe predicts one state at each for s. The frozen encoder processes the observed RGB frames. The probe spatially averages each temporal feature, selects the final temporal feature, and applies a two-layer pointwise nonlinear projection to predict all five future states jointly.
For each of the three encoder configurations, we train a separate five-horizon probe for 15 epochs using future-state labels from the probe-training split. We estimate normalization statistics separately for each variable and horizon on that split. The regression loss averages valid state values within each horizon, then weights the five horizons equally.
ID variables enter the encoder’s time-series supervision; OOD variables enter only supervised probe training. We compare original V-JEPA, the multi-domain video-fine-tuned control, and multi-domain Time-JEPA on the same future-label splits. Metrics are computed per variable and horizon on valid future labels, then averaged equally across variables and horizons.
In-Distribution Results
Table G1 breaks down the five-horizon ID results by domain and variable group. Table G2 resolves the horizon trend, and Table G3, Table G4, and Table G5 list the individual variables. Time-JEPA has the lowest nRMSE and the highest in all six domain–variable-group rows; its advantage over Video FT holds at every horizon in the three-domain aggregate.
Table G1: Five-horizon future-state prediction under . O/V/T denote original V-JEPA, the video-fine-tuned control, and Time-JEPA. Scores average variables and horizons equally within each domain and group. The final columns count horizon–variable cells with lower Time-JEPA RMSE than V/O (five per dimension). Each configuration and group uses one supervised joint state probe.
| Domain | Variables | Dims | nRMSE O | nRMSE V | nRMSE T | O | V | T | Time-JEPA RMSE wins vs. V | Time-JEPA RMSE wins vs. O |
| autonomous driving | 3 | 0.580 | 0.541 | 0.349 | 0.630 | 0.668 | 0.851 | 15/15 | 15/15 | |
| 3 | 0.640 | 0.598 | 0.488 | 0.575 | 0.625 | 0.748 | 15/15 | 15/15 | ||
| robot manipulation | 18 | 0.821 | 0.806 | 0.570 | 0.260 | 0.284 | 0.587 | 90/90 | 90/90 | |
| 8 | 0.876 | 0.865 | 0.722 | 0.209 | 0.228 | 0.444 | 40/40 | 40/40 | ||
| human motion | 9 | 1.022 | 1.027 | 0.913 | 0.204 | 0.198 | 0.375 | 44/45 | 43/45 | |
| 5 | 1.010 | 1.011 | 0.894 | 0.133 | 0.131 | 0.321 | 25/25 | 25/25 |
Table G1.
Table G2: Three-domain performance by future horizon. Domains are weighted by variable count. Final columns count variables with lower Time-JEPA RMSE than Video FT/Original; bold marks the best score.
| Horizon | nRMSE Original | nRMSE Video FT | nRMSE Time-JEPA | Original | Video FT | Time-JEPA | Time-JEPA RMSE wins vs. Video FT | Time-JEPA RMSE wins vs. Original |
| 0.2 s | 0.832 | 0.818 | 0.612 | 0.293 | 0.312 | 0.582 | 46/46 | 45/46 |
| 0.4 s | 0.876 | 0.861 | 0.679 | 0.282 | 0.304 | 0.544 | 46/46 | 46/46 |
| 0.6 s | 0.851 | 0.839 | 0.669 | 0.271 | 0.288 | 0.517 | 46/46 | 46/46 |
| 0.8 s | 0.850 | 0.840 | 0.682 | 0.262 | 0.278 | 0.495 | 46/46 | 46/46 |
| 1.0 s | 0.905 | 0.896 | 0.752 | 0.247 | 0.259 | 0.458 | 45/46 | 45/46 |
Table G2.
Table G3: autonomous driving: five-horizon future-state prediction by variable. O/V/T denote Original/Video FT/Time-JEPA; scores average five horizons under . Bold marks the best configuration.
| Group | Variable | nRMSE O | nRMSE V | nRMSE T | O | V | T |
| Longitudinal velocity | 0.280 | 0.245 | 0.110 | 0.899 | 0.923 | 0.984 | |
| Longitudinal acceleration | 0.917 | 0.894 | 0.601 | 0.278 | 0.313 | 0.685 | |
| Yaw rate | 0.541 | 0.483 | 0.335 | 0.714 | 0.769 | 0.882 | |
| Steering angle | 0.685 | 0.638 | 0.522 | 0.590 | 0.643 | 0.760 | |
| Lateral velocity | 0.604 | 0.550 | 0.435 | 0.656 | 0.713 | 0.818 | |
| Lateral acceleration | 0.632 | 0.607 | 0.506 | 0.479 | 0.518 | 0.664 |
Table G3.
Table G4: human motion: five-horizon future-state prediction by variable. O/V/T denote Original/Video FT/Time-JEPA. We average metrics equally over five horizons under . Bold marks the best configuration.
| Group | Variable | nRMSE O | V | T | O | V | T |
| Pelvis speed | 0.871 | 0.891 | 0.794 | 0.302 | 0.270 | 0.421 | |
| Left wrist relative speed | 1.008 | 1.012 | 1.003 | 0.214 | 0.207 | 0.223 | |
| Right wrist relative speed | 0.819 | 0.820 | 0.805 | 0.210 | 0.207 | 0.234 | |
| Left ankle relative speed | 1.844 | 1.853 | 1.821 | 0.092 | 0.082 | 0.121 | |
| Right ankle relative speed | 1.188 | 1.209 | 1.141 | 0.176 | 0.146 | 0.239 | |
| Left elbow flexion | 0.970 | 0.951 | 0.788 | 0.077 | 0.112 | 0.389 | |
| Right elbow flexion | 0.897 | 0.876 | 0.715 | 0.157 | 0.196 | 0.464 | |
| Left knee flexion | 0.792 | 0.817 | 0.587 | 0.394 | 0.355 | 0.667 | |
| Right knee flexion | 0.811 | 0.817 | 0.568 | 0.212 | 0.202 | 0.615 | |
| Inter-wrist distance | 0.909 | 0.894 | 0.853 | 0.283 | 0.305 | 0.367 | |
| Left wrist–shoulder distance | 1.018 | 1.033 | 0.894 | 0.066 | 0.038 | 0.282 | |
| Right wrist–shoulder distance | 0.910 | 0.910 | 0.776 | 0.152 | 0.152 | 0.383 | |
| Inter-ankle distance | 1.258 | 1.284 | 1.230 | 0.006 | −0.035 | 0.050 | |
| Pelvis support height | 0.956 | 0.936 | 0.718 | 0.160 | 0.194 | 0.525 |
Table G4.
Table G5: robot manipulation: five-horizon future-state prediction by variable. O/V/T denote Original/Video FT/Time-JEPA; scores average five horizons under . Bold marks the best configuration.
| Group | Variable | nRMSE O | V | T | O | V | T |
| Base translation speed | 0.886 | 0.881 | 0.849 | 0.108 | 0.117 | 0.181 | |
| Base angular speed | 0.754 | 0.757 | 0.722 | 0.104 | 0.096 | 0.177 | |
| Waist PC1 | 0.557 | 0.532 | 0.272 | 0.700 | 0.726 | 0.928 | |
| Waist PC2 | 0.574 | 0.569 | 0.402 | 0.697 | 0.703 | 0.851 | |
| Left arm position | 0.803 | 0.796 | 0.346 | 0.253 | 0.266 | 0.860 | |
| Left arm position | 0.630 | 0.616 | 0.263 | 0.553 | 0.572 | 0.921 | |
| Left arm position | 0.720 | 0.701 | 0.298 | 0.377 | 0.411 | 0.891 | |
| Right arm position | 0.801 | 0.761 | 0.362 | 0.384 | 0.444 | 0.872 | |
| Right arm position | 0.729 | 0.697 | 0.335 | 0.466 | 0.511 | 0.885 | |
| Right arm position | 0.740 | 0.703 | 0.300 | 0.390 | 0.449 | 0.896 | |
| Left end velocity | 0.994 | 0.982 | 0.820 | −0.014 | 0.011 | 0.294 | |
| Left end velocity | 0.926 | 0.924 | 0.796 | 0.010 | 0.016 | 0.266 | |
| Left end velocity | 1.032 | 1.025 | 0.925 | −0.027 | −0.012 | 0.178 | |
| Right end velocity | 0.939 | 0.927 | 0.748 | 0.000 | 0.023 | 0.355 | |
| Right end velocity | 1.027 | 1.014 | 0.827 | 0.020 | 0.045 | 0.364 | |
| Right end velocity | 1.055 | 1.046 | 0.936 | 0.002 | 0.019 | 0.221 | |
| Left gripper state | 0.778 | 0.761 | 0.523 | 0.394 | 0.421 | 0.726 | |
| Right gripper state | 0.830 | 0.812 | 0.529 | 0.258 | 0.291 | 0.698 | |
| Left joint-position norm | 0.660 | 0.663 | 0.435 | 0.471 | 0.466 | 0.770 | |
| Right joint-position norm | 0.832 | 0.805 | 0.505 | 0.317 | 0.361 | 0.748 | |
| Left joint-velocity norm | 0.911 | 0.890 | 0.744 | 0.149 | 0.188 | 0.427 | |
| Right joint-velocity norm | 0.906 | 0.893 | 0.750 | 0.171 | 0.196 | 0.429 | |
| Left joint-effort norm | 0.765 | 0.760 | 0.641 | 0.217 | 0.228 | 0.449 | |
| Right joint-effort norm | 1.017 | 1.005 | 0.861 | 0.177 | 0.196 | 0.411 | |
| Left wrench-force norm | 0.756 | 0.749 | 0.713 | 0.027 | 0.044 | 0.133 | |
| Right wrench-force norm | 1.157 | 1.154 | 1.127 | 0.143 | 0.147 | 0.187 |
Table G5.
Held-Out Conditions
Table G6 evaluates the same fitted probes under : stable rain for autonomous driving, both fisheye views for robot manipulation, and exocentric view03 for human motion.
| Domain | Variables | Original | Video FT | Time-JEPA | Original | Video FT | Time-JEPA |
| autonomous driving | 0.548 | 0.515 | 0.333 | 0.580 | 0.620 | 0.812 | |
| 0.590 | 0.570 | 0.449 | 0.512 | 0.543 | 0.711 | ||
| robot manipulation | 0.975 | 0.973 | 0.952 | −0.012 | −0.010 | 0.006 | |
| 1.007 | 0.980 | 0.964 | −0.042 | 0.013 | −0.003 | ||
| human motion | 1.045 | 1.047 | 0.902 | 0.165 | 0.162 | 0.391 | |
| 1.010 | 1.006 | 0.888 | 0.134 | 0.142 | 0.330 |
Table G6. Multi-horizon future-state prediction under by domain and variable group. We average metrics equally over the five horizons. Bold marks the best score for each domain, variable group, and metric.
Across the six domain–variable-group settings under , Time-JEPA improves 11 of 12 reported metric comparisons over Video FT: nRMSE decreases in all six settings, and increases in five.
Long-Horizon Persistence Extension
We separately train six eight-horizon probes on frozen multi-domain Time-JEPA features, one per domain and variable group, for s. Figure G1 compares them with persistence, which holds the ground-truth state at fixed, and estimated persistence, which holds a separate video-based current-state probe’s estimate fixed.
Figure G1. Long-horizon persistence extension under . Panels (a) and (b) compare the eight-horizon Time-JEPA probe with persistence and estimated persistence, respectively. Curves give variable-macro nRMSE over 30 and 16 variables. Panel (a) uses valid current and future labels; panel (b) uses valid future labels.
The ground-truth comparison requires valid current and future labels; we recompute the future-probe error on those same samples. The estimated comparison requires only valid future labels. Each horizon reports nRMSE averaged equally over 46 variables from test views.
Time-JEPA has lower variable-macro nRMSE than persistence at 0.6–1.6 s, while persistence has lower error at 0.2–0.4 s. Time-JEPA has lower error than estimated persistence at all eight horizons (Figure G1). Together, the two comparisons suggest that this advantage reflects prediction of future physical-state evolution rather than only current-state estimation: the ground-truth-current baseline supplies the exact state at , whereas estimated persistence holds a video-based current-state estimate fixed, and Time-JEPA outperforms them from 0.6–1.6 s and at all eight horizons, respectively.
External Physical Evaluations
We compare original V-JEPA, the multi-domain video-fine-tuned control, and multi-domain Time-JEPA. GRASP directly evaluates the frozen online encoder, target encoder, and predictor. Physion trains a supervised logistic probe on frozen target-encoder features.
GRASP Violation-of-Expectation Protocol
GRASP Level 2 contains 16 test families with 128 matched possible/impossible pairs per family, for 2,048 pairs in total [16]. We sample the 50-FPS videos every tenth frame, process 16-frame windows with stride 2, and apply the same , prediction mask to every configuration. For each window, we compute the latent prediction error between normalized predicted and target hierarchical features, then average the window scores over the video. The higher-surprise video receives the impossible label, and ties count as errors. The primary metric averages pair accuracy equally over the eight non-empty intuitive-physics properties. A multi-label family contributes to each property listed for that family.
| Configuration | Pair accuracy (%) | vs. Video FT (pp) |
| Original V-JEPA | 50.658 | |
| Video FT | 55.560 | |
| Time-JEPA | 57.751 | +2.191 |
Table H1. GRASP eight-property macro pair accuracy. We score all 2,048 Level 2 pairs with the fixed , protocol. The primary metric averages the eight property accuracies equally. Differences use percentage points relative to Video FT. Bold marks the highest accuracy.
| Property | Pairs | Original | Video FT | Time-JEPA | Time-JEPA Video FT |
| Object Permanence | 384 | 56.510 | 65.885 | 70.052 | +4.167 |
| Continuity | 512 | 55.078 | 55.469 | 56.250 | +0.781 |
| Color Constancy | 256 | 32.422 | 58.984 | 53.125 | |
| Support | 128 | 100.000 | 99.219 | 97.656 | |
| Inertia | 512 | 36.328 | 38.672 | 41.016 | +2.344 |
| Gravity | 640 | 42.500 | 44.219 | 46.250 | +2.031 |
| Solidity | 256 | 82.422 | 80.469 | 86.719 | +6.250 |
| Collision | 128 | 0.000 | 1.563 | 10.938 | +9.375 |
Table H2. GRASP pair accuracy by intuitive-physics property. Each row uses the matched pairs assigned to that property. Differences use percentage points relative to Video FT. Bold marks the highest encoder point estimate in each row.
Time-JEPA improves six of eight properties over the video-fine-tuned control.
Physion Object-Contact Prediction
Physion v1.5 Object Contact Prediction asks whether a designated agent and patient object will contact after an observed RGB prefix. The compact split contains 5,608 training and 1,035 test stimuli across collide, drop, support, link, roll, contain, and dominoes. The test positive rate is 50.531%. Ordinary stimuli use source frames [0, 15, 30, 45] at 150-ms spacing, while the fast-collision case uses [0, 0, 0, 15].
We spatially average the frozen target encoder’s final-layer tokens within each of two temporal tubelets and flatten the [2, 1408] array into a 2,816D feature. Model selection includes feature standardization. In each cross-validation fold, we compute every feature dimension’s mean and standard deviation from that fold’s training portion and apply them to its validation portion. Five-fold cross-validation preserves the label ratio in every fold and selects by mean validation Accuracy. is the inverse regularization strength, so larger values impose a weaker penalty. After selecting , we recompute the standardization statistics on all permitted training examples, refit the L2-regularized logistic classifier on those standardized features, and evaluate it once on the corresponding test set using the same final training statistics.
The all-scenario readout fits one classifier using all seven training scenarios and evaluates all test scenarios. The leave-one-scenario-out transfer protocol fits seven classifiers, each excluding one scenario from readout training and evaluating only that scenario. Supervised probe training excludes the scenario evaluated in each transfer task.
We fit all probes on chronological features. The temporally shuffled input condition reorders the same four test frames and retains the labels and fitted classifiers. This condition tests sensitivity to an OOD change in frame order.
Physion Macro and Overall Results
Table H3 weights scenarios equally, whereas Table H4 pools all stimuli. Under chronological all-scenario evaluation, Time-JEPA changes Accuracy by only macro and pooled points, while increasing AUROC by 1.182 and 1.465 points. Under leave-one-scenario-out transfer, Accuracy/AUROC improve by 2.945/3.997 macro points and 2.705/3.142 pooled points.
| Configuration | Readout setting | Chronological Acc. ↑ | Chronological AUROC ↑ | Temporally shuffled Acc. ↑ | Temporally shuffled AUROC ↑ |
| Original | All-scenario | 71.511 | 79.573 | 61.490 | 67.831 |
| Video FT | All-scenario | 75.063 | 81.361 | 64.578 | 72.270 |
| Time-JEPA | All-scenario | 75.062 | 82.543 | 63.470 | 72.523 |
| Original | Leave-one-scenario-out | 59.368 | 63.076 | 54.504 | 58.146 |
| Video FT | Leave-one-scenario-out | 57.952 | 62.028 | 54.415 | 58.647 |
| Time-JEPA | Leave-one-scenario-out | 60.897 | 66.024 | 54.010 | 60.066 |
Table H3. Physion scenario-macro Accuracy and AUROC. We average percentages equally over seven scenarios. Chronological and temporally shuffled inputs reuse the same fitted probes. Bold marks the highest value per protocol and metric.
| Configuration | All-scenario chronological Acc. ↑ | All-scenario chronological AUROC ↑ | All-scenario shuffled Acc. ↑ | All-scenario shuffled AUROC ↑ | Leave-one-scenario-out chronological Acc. ↑ | Leave-one-scenario-out chronological AUROC ↑ | Leave-one-scenario-out shuffled Acc. ↑ | Leave-one-scenario-out shuffled AUROC ↑ |
| Original | 71.401 | 80.100 | 61.739 | 67.737 | 59.034 | 61.430 | 54.106 | 55.592 |
| Video FT | 74.686 | 82.029 | 64.638 | 71.675 | 57.681 | 60.914 | 54.010 | 57.212 |
| Time-JEPA | 74.783 | 83.494 | 63.768 | 72.366 | 60.386 | 64.056 | 54.010 | 57.748 |
Table H4. Physion overall Accuracy and AUROC. Percentages pool all 1,035 test stimuli. Larger scenarios receive more weight than in Table H3. Chronological and temporally shuffled inputs use the same fitted probes. Bold marks the highest value per condition and metric.
For leave-one-scenario-out transfer, the matched Time-JEPA difference changes from / Accuracy/AUROC points on chronological inputs to / points after shuffling. This drop suggests that the held-out-scenario readout uses temporal information in addition to static appearance cues.
Under the all-scenario readout, Time-JEPA improves AUROC over the video-fine-tuned control in six of seven scenarios while Accuracy changes have mixed signs.
Under leave-one-scenario-out transfer, Time-JEPA improves both metrics on collide, contain, dominoes, and support. Both decrease on drop, while link and roll show mixed changes. The scenario-macro result weights all seven phenomena equally.
| Scenario () | All-scenario change Acc. | All-scenario change AUROC | Leave-one-scenario-out change Acc. | Leave-one-scenario-out change AUROC | Time-JEPA leave-one-scenario-out Acc. | Time-JEPA leave-one-scenario-out AUROC |
| Collide (105) | −1.905 | +0.472 | +6.667 | +10.704 | 66.667 | 71.662 |
| Contain (153) | +1.961 | +3.179 | +5.882 | +7.915 | 61.438 | 68.256 |
| Dominoes (159) | −1.887 | +0.712 | +4.403 | +9.525 | 51.572 | 58.244 |
| Drop (157) | −1.274 | +0.552 | −4.459 | −3.117 | 58.599 | 64.188 |
| Link (157) | +1.911 | −1.186 | −1.274 | +1.186 | 56.688 | 63.759 |
| Roll (157) | +2.548 | +3.805 | +1.911 | −1.366 | 49.682 | 47.154 |
| Support (147) | −1.361 | +0.741 | +7.483 | +3.130 | 81.633 | 88.907 |
Table H5. Physion results by scenario with chronological input. Changes give Time-JEPA minus Video FT in percentage points. The final two columns give Time-JEPA Accuracy and AUROC in percent. Bold marks the largest value in each column.
Design Ablations
The human motion ablations cover three design questions: temporal aggregation in the auxiliary head, downstream probe capacity, and supervision breadth. Unless stated otherwise, the evaluation uses the same nine current-state variables, five geometric variables, seen exocentric views, and held-out exocentric view03 view as the main protocol. We average metrics equally over views and variables. We remove each auxiliary head and train a new probe on the frozen encoder.
Temporal Aggregation in the Auxiliary Head
The main pointwise nonlinear auxiliary head applies the same nonlinear channel projection independently at each temporal position. We compare it with near-parameter-matched heads (approximately 2M trainable parameters). Local convolution mixes three neighboring positions, and dense multi-scale convolution uses temporal spans of 3, 5, and 9. Global attention mixes all 32 temporal positions, local attention uses a nine-position window, and the hybrid uses four local and four global attention heads. All variants retain the same final-feature interface, 9D tubelet-level state values, training protocol, and pointwise nonlinear evaluation probe.
Global attention gives the highest Pearson and on all four panels (Figure I1), exceeding the pointwise nonlinear head by 0.005–0.009 in each metric. Local and hybrid attention give similar small gains, while dense multi-scale convolution degrades most panels. The encoder’s spatiotemporal self-attention already mixes information across temporal positions, so further aggregation in the auxiliary head may be largely redundant in this setting. We therefore retain the pointwise nonlinear head.
Figure I1. human motion auxiliary-head temporal aggregation. Grouped bars show changes from the pointwise nonlinear auxiliary head on the four variable–condition panels. Labels give each three-decimal change. The four solid colors denote the four variable–condition combinations. The left and right panels report Pearson and , respectively, and the gray vertical reference marks zero change. All frozen encoders use the matched pointwise nonlinear probe.
Probe-Capacity Check
We compare the pointwise nonlinear probe with a linear probe that spatially pools each temporal feature and applies LayerNorm + Linear. The linear probe has 15,497 parameters for and 9,861 for . The pointwise nonlinear probe has 1,996,553 and 1,990,917 parameters, respectively. Both operate independently at each temporal position.
The linear probe preserves the Time-JEPA advantage on all four panels and all three metrics (Table II). Its matched gains span 0.045–0.074 in Pearson and 0.051–0.095 in , with RMSE reductions of 0.022–0.055. The pointwise probe yields larger effects but the same encoder ordering. The continued gains with a much smaller linear probe suggest that they reflect the frozen encoder representation rather than the pointwise probe architecture in this setting.
Supervision Breadth
We compare aligned supervision on pelvis speed alone (1D), five motion-speed quantities, and the full 9D set including four flexion angles.
| Panel | ↑ Linear | ↑ Pointwise nonlinear | ↑ Linear | ↑ Pointwise nonlinear | nRMSE reduction ↑ Linear | nRMSE reduction ↑ Pointwise nonlinear |
| ID, ID | 0.066 | 0.086 | 0.084 | 0.114 | 0.048 | 0.068 |
| ID, OOD | 0.074 | 0.096 | 0.095 | 0.133 | 0.055 | 0.076 |
| OOD, ID | 0.045 | 0.069 | 0.051 | 0.089 | 0.022 | 0.035 |
| OOD, OOD | 0.046 | 0.063 | 0.054 | 0.090 | 0.023 | 0.034 |
Table I1. human motion probe-capacity check. Changes compare Time-JEPA with Video FT within each probe family. We report nRMSE reduction as Video FT minus Time-JEPA. Variable and condition notation follows § 4.2. ID averages seen exocentric views, and OOD uses held-out exocentric view03. Bold marks the larger matched gain.
Both reduced aligned encoders improve both metrics over the video-fine-tuned control on all four standard panels, but remain below full aligned supervision (Table I2). The decomposition in Table I3 shows that focused supervision remains close to full supervision on included semantics. Motion-only supervision loses most on excluded flexion variables, and all five OOD geometric variables also decline. The 1D and 5D controls have similar scores. The larger gains from full supervision suggest that coverage of complementary physical quantities supports transfer.
| Encoder supervision | ID ID ↑ | ID ID ↑ | ID OOD ↑ | ID OOD ↑ | OOD ID ↑ | OOD ID ↑ | OOD OOD ↑ | OOD OOD ↑ |
| Video FT | 0.503 | 0.231 | 0.486 | 0.199 | 0.434 | 0.133 | 0.452 | 0.135 |
| Full 9D aligned | 0.589 | 0.345 | 0.581 | 0.332 | 0.504 | 0.222 | 0.515 | 0.225 |
| Pelvis-only 1D aligned | 0.546 | 0.279 | 0.534 | 0.256 | 0.453 | 0.156 | 0.469 | 0.157 |
| Motion-speed 5D aligned | 0.551 | 0.284 | 0.537 | 0.259 | 0.452 | 0.155 | 0.470 | 0.158 |
Table I2. human motion supervision breadth. We average Pearson and equally over views, then variables. Variable and condition notation follows § 4.2. Bold marks the best supervision condition per panel and metric.
| Reduced supervision | Variable subset | ↑ | ↑ | ↑ | ↑ |
| Pelvis-only 1D | Included | +0.013 | +0.017 | +0.004 | −0.001 |
| Excluded | −0.050 | −0.077 | −0.054 | −0.085 | |
| Motion-speed 5D | Included | +0.004 | +0.005 | −0.001 | −0.001 |
| Excluded | −0.091 | −0.144 | −0.098 | −0.164 |
Table I3. Semantic decomposition of reduced supervision. Changes give reduced minus full-aligned performance. Included/Excluded indicate whether a full-model variable enters the reduced objective.
Sensitivity Analysis
We test how temporal alignment and sensor noise affect the human motion representation. Each experiment perturbs only the physical time series used for encoder fine-tuning. Probe training and evaluation use clean state labels. All encoders use the same full 9D state-variable set, training protocol, and pointwise nonlinear auxiliary head. We remove that head and train a matched pointwise nonlinear Readout on each frozen encoder. The results average views equally before averaging the nine variables equally and report seen exocentric views as and held-out exocentric as .
Temporal Misalignment
The fixed-offset condition pairs each video time with the state sequence 0.8 s later. The cross-take condition pairs every video window with a 9D state sequence from a different take through a one-to-one permutation. The latter condition preserves the dataset-level state-value and validity-mask multisets but removes local video–state correspondence.
| Condition | Metric | Video FT | Clean alignment | 0.8 s offset | Cross-take |
| ↑ | 0.503 | 0.589 | 0.575 | 0.510 | |
| ↑ | 0.231 | 0.345 | 0.329 | 0.242 | |
| nRMSE ↓ | 0.742 | 0.674 | 0.683 | 0.735 | |
| ↑ | 0.486 | 0.581 | 0.570 | 0.498 | |
| ↑ | 0.199 | 0.332 | 0.320 | 0.219 | |
| nRMSE ↓ | 0.761 | 0.685 | 0.692 | 0.750 |
Table J1. human motion sensitivity to temporal misalignment. The pointwise nonlinear Readout uses clean labels for every frozen encoder. Metrics average views before the nine variables. Bold marks the best unrounded score in each row.
Cross-take misalignment causes a larger decline than the 0.8 s offset and approaches the video-fine-tuned control. Across Pearson and , it retains only about 5–15% of the clean-alignment gain over Video FT.
Sensor Noise
We add zero-mean Gaussian noise to each fine-tuning state variable with a standard deviation equal to that variable’s clean training-set standard deviation. This gives the noise a standard deviation of 1 after state-value normalization.
The evaluation covers temporal pairing errors and noisy state values under both seen and held-out views; each perturbation reduces performance.
| Condition | Metric | Clean | Gaussian noise |
| 0.589 | 0.580 | ||
| 0.345 | 0.332 | ||
| 0.674 | 0.682 | ||
| 0.581 | 0.570 | ||
| 0.332 | 0.315 | ||
| 0.685 | 0.695 |
Table J2. human motion sensitivity to Gaussian sensor noise. The pointwise nonlinear Readout uses clean labels. Metrics average views before the nine variables. Bold marks the better unrounded score in each row.
Alternative Forms of Physical Supervision
We compare supervision on individual frames or frame pairs with Time-JEPA in robot manipulation, then add an explicit physical-law constraint to Time-JEPA in autonomous driving. All evaluations fit supervised, video-only probes on frozen representations; variables still have probe labels (§ 4.2). Time-JEPA and Time-JEPA+Law use their exponential-moving-average encoders. Future-state and nRMSE average the five horizons s equally, where is the final observed frame; nRMSE uses each variable’s probe-training standard deviation. Current-and future-state tables use one probe run per fixed encoder; Table K5 uses five paired probe seeds.
| Metric | ID Time-JEPA | ID Time-JEPA+Law | OOD Time-JEPA | OOD Time-JEPA+Law |
| Integration-law AUROC | 0.694 ± 0.004 | 0.683 ± 0.005 | 0.672 ± 0.009 | 0.661 ± 0.010 |
| Integrated trajectory MAE (m) | 3.080 ± 0.114 | 3.252 ± 0.128 | 3.572 ± 0.312 | 3.875 ± 0.359 |
| Direct trajectory MAE (m) | 3.482 ± 0.068 | 3.534 ± 0.066 | 3.967 ± 0.565 | 4.072 ± 0.677 |
| – residual, 0.5 s (m/s) | 0.523 ± 0.020 | 0.374 ± 0.016 | 0.658 ± 0.038 | 0.464 ± 0.031 |
| – residual, 1.0 s (m/s) | 0.695 ± 0.027 | 0.531 ± 0.024 | 0.790 ± 0.042 | 0.594 ± 0.038 |
| – residual, 2.0 s (m/s) | 0.957 ± 0.039 | 0.774 ± 0.039 | 1.016 ± 0.045 | 0.814 ± 0.045 |
Table K5. Law satisfaction and trajectory reconstruction in autonomous driving. AUROC and trajectory MAE average 1.00, 2.00, and 2.95 s; AUROC also averages five alternatives. Residuals are mean absolute values. Entries are mean ± sample standard deviation over five paired probe seeds on one fixed encoder per method; bold marks the better mean.
Supervision on Individual Frames or Frame Pairs
Training objectives. We adapt PSG-JEPA ([29]) to the released V-JEPA 2.1 ViT-g/16 image branch. Both variants independently encode frames, pool spatial tokens, and project them; both retain the action-conditioned latent predictor and SIGReg regularizer. Each 64-frame window supplies 16 four-frame sequences.
Static regresses the aligned 18D state from each frame. Full adds two heads on paired frame latents: one predicts changes in ten configuration coordinates (two waist components, six end-effector positions, and two gripper positions) across all frame pairs in each four-frame sequence, averaging the three separations equally. The other predicts base translation and angular speed and six end-effector velocities from adjacent pairs at the earlier frame. All terms use mean squared error on valid, standardized values:
Here, is latent next-step prediction. Time-JEPA instead supervises temporally contextualized video features at each aligned tubelet, alongside masked spatiotemporal JEPA prediction.
Matched data and probes. All models start from the released checkpoint and use the same 5,000 physical windows rendered in three views (15,000 view-specific windows), 64 frames at 5 FPS, 384 × 384 resolution, 18D state panel and normalization, 20 epochs, global batch size 64, and encoder seed 239. Static and Full use their final checkpoints; the future-state Time-JEPA encoder is single-domain.
We remove training heads and freeze the representations. Static and Full keep their image encoder and projector, averaging adjacent frames into 32 temporal positions. Matched pointwise nonlinear probes predict all five future horizons jointly from the final feature. They use 15 epochs, learning rate , global batch size 16, seed 0, and validation-loss selection. Current-state train/validation/test counts are 4,500/1,500/1,000 windows per view; requiring future labels gives 4,440/1,176/989.
Variables and aggregation. We evaluate 18 and 8 variables (xref}Appendix D). Current-state averages three seen views; future-state uses the head camera. averages two held-out fisheye views. We average selected variables and views equally. Unlike Table 1.
Results. Time-JEPA leads on both metrics in all eight settings (Table K1–Table K2) and at each future horizon under both condition groups. Full improves on Static in all four ID settings but lowers in all four OOD settings; its current-state Pearson gains under held-out views coexist with poorer absolute fit. Time-JEPA’s OOD/OOD reaches −0.012 at 1.0 s despite its positive five-horizon average. This advantage is consistent with the value of supervising evolving physical state on features that incorporate the video’s full temporal context.
| Condition | Variables | Static ↑ | Static ↑ | Full ↑ | Full ↑ | Time-JEPA ↑ | Time-JEPA ↑ |
| ID | ID | 0.273 | 0.493 | 0.397 | 0.628 | 0.725 | 0.845 |
| OOD | 0.270 | 0.512 | 0.373 | 0.602 | 0.568 | 0.741 | |
| OOD | ID | −0.073 | 0.059 | −0.137 | 0.118 | 0.269 | 0.688 |
| OOD | −0.061 | 0.056 | −0.111 | 0.123 | 0.205 | 0.555 |
Table K1. Current-state decoding in robot manipulation. ID averages three seen views; OOD averages variables across two fisheye views. Higher and Pearson are better; bold marks the best score.
| Condition | Variables | Static ↑ | Static nRMSE ↓ | Full ↑ | Full nRMSE ↓ | Time-JEPA ↑ | Time-JEPA nRMSE ↓ |
| ID | ID | 0.217 | 0.853 | 0.302 | 0.804 | 0.506 | 0.647 |
| OOD | 0.167 | 0.900 | 0.243 | 0.857 | 0.379 | 0.771 | |
| OOD | ID | −0.081 | 1.014 | −0.116 | 1.029 | 0.100 | 0.919 |
| OOD | −0.053 | 1.012 | −0.077 | 1.023 | 0.047 | 0.951 |
Table K2. Future-state prediction in robot manipulation. ID uses the head camera; OOD averages variables across two fisheye views. Five horizons span 0.2–1.0 s. Higher and lower nRMSE are better; bold marks the best score.
Adding Explicit Physical-Law Constraints
Training objective. We augment the single-domain autonomous driving Time-JEPA with a longitudinal kinematic constraint, denoting the variant Time-JEPA+Law. It reuses the existing speed, acceleration, and yaw-rate auxiliary head and adds no trainable parameters. We convert its speed and acceleration back to physical units using the original training-set statistics, denoting them and at tubelet . For adjacent tubelets, we penalize the trapezoidal integration residual
We obtain from decoded video timestamps at tubelet centers. Valid pairs require speed and acceleration on all four frames, increasing frame times, and s. State-label alignment and validity masks remain unchanged.
For the set of valid pairs, the added term and total objective are
The fixed is the sample standard deviation of valid ground-truth speed differences from one clip per each of 6,305 training videos. The original and 250-step warmup apply to both auxiliary terms; the law term’s final effective weight is 0.1.
Evaluation protocol. The models share the training split, backbone, state variables, normalization, schedule, and final 20-epoch checkpoint. Matched probes use 15 epochs, global batch size 32, seed 239, and validation-loss selection on 1,349 train and 449 validation videos. Tests contain 900 ID and 521 rainy OOD videos. Both tasks evaluate the three ID and three OOD$_{\mathrm{var}} variables in Appendix D. The Time-JEPA current-state probes are reused; future-state probes use the same single-domain encoder.
Results. At and the fixed budget, the constraint lowers both current-state metrics and future-state , while raising future-state nRMSE, in all four settings (Table K3 and Table K4). Future nRMSE rises at every horizon for both variable and condition groups.
| Condition | Variables | Time-JEPA | Time-JEPA | Time-JEPA+Law | Time-JEPA+Law |
| ID | ID | 0.849 | 0.916 | 0.809 | 0.890 |
| OOD | 0.846 | 0.920 | 0.831 | 0.912 | |
| OOD | ID | 0.824 | 0.902 | 0.780 | 0.878 |
| OOD | 0.876 | 0.937 | 0.863 | 0.930 |
Table K3. Current-state decoding in autonomous driving. Each variable group averages three variables; OOD is rainy weather. Higher and Pearson are better; bold marks the better score.
| Condition | Variables | Time-JEPA | Time-JEPA nRMSE | Time-JEPA+Law | Time-JEPA+Law nRMSE |
| ID | ID | 0.719 | 0.485 | 0.699 | 0.503 |
| OOD | 0.667 | 0.560 | 0.648 | 0.576 | |
| OOD | ID | 0.680 | 0.460 | 0.667 | 0.469 |
| OOD | 0.604 | 0.529 | 0.594 | 0.536 |
Table K4. Future-state prediction in autonomous driving. Scores average three variables per group and five horizons equally; OOD is rainy weather. Higher and lower nRMSE are better; bold marks the better score.
Law satisfaction and trajectory reconstruction. Eleven independent scalar probes (seeds 0–4) on the fixed encoders decode longitudinal/lateral velocity, yaw rate, six trajectory coordinates, speed, and acceleration. We integrate motion states and compare endpoints with ground truth as in Appendix E; integration-law AUROC compares this reconstruction with five fixed alternatives. We also measure the mean absolute speed–acceleration residual at s, using trapezoidal integration and 0.5 s tubelet intervals:
The constraint lowers local residuals at all horizons, yet integration-law AUROC falls and trajectory MAE rises by 5.6%/8.5% under ID/OOD. This pattern is consistent with explicit constraints favoring specified dynamics over other video changes, as discussed in the Introduction.
References
- [1]Pulkit Agrawal, Joao Carreira, and Jitendra Malik. Learning to see by moving. In Proc. ICCV, Santiago, 2015.arxiv.org/abs/1505.01596
- [2]Hidehisa Arai, Keita Miwa, Kento Sasaki, Kohei Watanabe, Yu Yamaguchi, Shunsuke Aoki, and Issei Yamamoto. Covla: Comprehensive vision-language-action dataset for autonomous driving. In Proc. WACV, Tucson, 2025.arxiv.org/abs/2408.10845
- [3]Mahmoud Assran, Quentin Duval, Ishan Misra, Piotr Bojanowski, Pascal Vincent, Michael Rabbat, Yann LeCun, and Nicolas Ballas. Self-supervised learning from images with a joint-embedding predictive architecture. In Proc. CVPR, Vancouver, 2023.arxiv.org/abs/2301.08243
- [4]Mido Assran, Adrien Bardes, David Fan, Quentin Garrido, Russell Howes, Mojtaba Komeili, Matthew Muckley, Ammar Rizvi, Claire Roberts, Koustuv Sinha, et al. V-jepa 2: Self-supervised video models enable understanding, prediction and planning, 2025. URL https://arxiv.org/abs/2506.09985, 2025.
- [5]Anton Bakhtin, Laurens van der Maaten, Justin Johnson, Laura Gustafson, and Ross Girshick. Phyre: A new benchmark for physical reasoning. In Proc. NeurIPS, Vancouver, 2019.arxiv.org/abs/1908.05656
- [6]Adrien Bardes, Quentin Garrido, Jean Ponce, Xinlei Chen, Michael Rabbat, Yann LeCun, Mahmoud Assran, and Nicolas Ballas. Revisiting feature prediction for learning visual representations from video. arXiv preprint arXiv:2404.08471, 2024.arxiv.org/abs/2404.08471
- [7]Daniel M Bear, Elias Wang, Damian Mrowca, Felix J Binder, Hsiao-Yu Fish Tung, RT Pramod, Cameron Holdaway, Sirui Tao, Kevin Smith, Fan-Yun Sun, et al. Physion: Evaluating physical prediction from vision in humans and machines. 2021.arxiv.org/abs/2106.08261
- [8]Qingwen Bu, Jisong Cai, Li Chen, Xiuqi Cui, Yan Ding, Siyuan Feng, Shenyuan Gao, Xindong He, Xuan Hu, Xu Huang, et al. Agibot world colosseo: A large-scale manipulation platform for scalable and intelligent embodied systems. arXiv preprint arXiv:2503.06669, 2025.arxiv.org/abs/2503.06669
- [9]Dian Chen, Brady Zhou, Vladlen Koltun, and Philipp Krähenbühl. Learning by cheating. In Proc. CoRL, Conference held virtually, 2020.arxiv.org/abs/1912.12294
- [10]Christoph Feichtenhofer, Yanghao Li, Kaiming He, et al. Masked autoencoders as spatiotemporal learners. In Proc. NeurIPS, New Orleans, 2022.arxiv.org/abs/2205.09113
- [11]Quentin Garrido, Nicolas Ballas, Mahmoud Assran, Adrien Bardes, Laurent Najman, Michael Rabbat, Emmanuel Dupoux, and Yann LeCun. Intuitive physics understanding emerges from self-supervised pretraining on natural videos. arXiv preprint arXiv:2502.11831, 2025.arxiv.org/abs/2502.11831
- [12]Kristen Grauman, Andrew Westbury, Lorenzo Torresani, Kris Kitani, Jitendra Malik, Triantafyllos Afouras, Kumar Ashutosh, Vijay Baiyya, Siddhant Bansal, Bikram Boote, et al. Ego-exo4d: Understanding skilled human activity from first-and third-person perspectives. In Proc. CVPR, Seattle, 2024.
- [13]Vincent Le Guen and Nicolas Thome. Disentangling Physical Dynamics From Unknown Factors for Unsupervised Video Prediction. In Proc. CVPR, Conference held virtually, 2020.arxiv.org/abs/2003.01460
- [14]Saurabh Gupta, Judy Hoffman, and Jitendra Malik. Cross modal distillation for supervision transfer. In Proc. CVPR, Las Vegas, 2016.arxiv.org/abs/1507.00448
- [15]Danijar Hafner, Timothy Lillicrap, Jimmy Ba, and Mohammad Norouzi. Dream to Control: Learning Behaviors by Latent Imagination. In Proc. ICLR, Conference held virtually, 2020.arxiv.org/abs/1912.01603
- [16]Serwan Jassim, Mario Holubar, Annika Richter, Cornelius Wolff, Xenia Ohmer, and Elia Bruni. Grasp: A novel benchmark for evaluating language grounding and situated physics understanding in multimodal language models. arXiv preprint arXiv:2311.09048, 2023.arxiv.org/abs/2311.09048
- [17]Sonia Joseph, Quentin Garrido, Randall Balestriero, Matthew Kowal, Thomas Fel, Shahab Bakhtiari, Blake Richards, and Mike Rabbat. Interpreting physics in video world models. arXiv preprint arXiv:2602.07050, 2026.arxiv.org/abs/2602.07050
- [18]Zhenjiang Mao, Mrinall Eashaan Umasudhan, and Ivan Ruchkin. Physically Interpretable World Models via Weakly Supervised Representation Learning. In Proc. ICCPS, Saint Malo, 2026.arxiv.org/abs/2412.12870
- [19]Lorenzo Mur-Labadia, Matthew Muckley, Amir Bar, Mido Assran, Koustuv Sinha, Mike Rabbat, Yann LeCun, and Nicolas Ballas. V-jepa 2.1: Unlocking dense features in video self-supervised learning. In Proc. ECCV, Malmö, 2026.
- [20]Abdullah Mustafa, Ryo Hanai, Ixchel G. Ramirez-Alpizar, Floris Erich, Ryoichi Nakajo, Yukiyasu Domae, and Tetsuya Ogata. Visual Imitation Learning of Non-Prehensile Manipulation Tasks with Dynamics-Supervised Models. In Proc. CASE, Bari, 2024.arxiv.org/abs/2410.19379
- [21]Samuele Punzo, Niccolò Caselli, Ippokratis Pantelidis, Francesco Massafra, Salvatore Lo Sardo, and Mohammadreza Salehi. How Do Video Foundation Models Encode Intuitive Physics? Probing Across Pretraining Paradigms. arXiv preprint arXiv:2606.09646, 2026.arxiv.org/abs/2606.09646
- [22]Yu Shang, Xin Zhang, Yinzhou Tang, Lei Jin, Chen Gao, Wei Wu, and Yong Li. RoboScape: Physics-informed Embodied World Model. In Proc. NeurIPS, San Diego and Mexico City, 2025.arxiv.org/abs/2506.23135
- [23]Ying Shen, Jerry Xiong, Tianjiao Yu, and Ismini Lourentzou. PHANTOM: Physics-Infused Video Generation via Joint Modeling of Visual and Latent Physical Dynamics. In Proc. CVPR, Denver, 2026.arxiv.org/abs/2604.08503
- [24]Zhan Tong, Yibing Song, Jue Wang, and Limin Wang. Videomae: Masked autoencoders are data-efficient learners for self-supervised video pre-training. In Proc. NeurIPS, New Orleans, 2022.arxiv.org/abs/2203.12602
- [25]Chenting Wang, Yuhan Zhu, Yicheng Xu, Jiange Yang, Lang Lin, Xiang Yan, Yali Wang, Yi Wang, and Limin Wang. Intervideo-next: Towards general video foundation models without video-text supervision. arXiv preprint arXiv:2512.01342, 2025.arxiv.org/abs/2512.01342
- [26]Limin Wang, Bingkun Huang, Zhiyu Zhao, Zhan Tong, Yinan He, Yi Wang, Yali Wang, and Yu Qiao. Videomae v2: Scaling video masked autoencoders with dual masking. In Proc. CVPR, Vancouver, 2023.arxiv.org/abs/2303.16727
- [27]Kehan Wen, Ziming Li, Siyuan Luo, and Fan Shi. JEPA-x: Cross-Predictive Physics Grounding for Forecastable Latent Dynamics. arXiv preprint arXiv:2608.24044, 2026.arxiv.org/abs/2608.24044
- [28]Jialong Wu, Shaofeng Yin, Ningya Feng, Xu He, Dong Li, Jianye Hao, and Mingsheng Long. videogpt: Interactive videogpts are scalable world models. In Proc. NeurIPS, Vancouver, 2024.arxiv.org/abs/2405.15223
- [29]Haodong Yan, Jiaquan Zhu, Mingyuan Jia, Ruiqing Yin, Junjie He, Zhide Zhong, Junfeng Li, Jinxuan Lu, Hengt ao Li, Tianran Zhang, Jiayi Chen, Wenxuan Song, Wen Chen, Yuxiang Gao, and Haoang Li. Is Forward Prediction Enough? Physical State Grounding for JEPA World Models. arXiv preprint arXiv:2608.06799, 2026.arxiv.org/abs/2608.06799
- [30]Kexin Yi, Chuang Gan, Yunzhu Li, Pushmeet Kohli, Jiajun Wu, Antonio Torralba, and Joshua B Tenenbaum. Clever: Collision events for video representation and reasoning. 2019.arxiv.org/abs/1910.01442
- [31]Xi Zeng, Haojie Ren, and Ziying Song. PhyLatent: Learning Dynamics-Relevant Representations for JEPA World Models. arXiv preprint arXiv:2608.05720, 2026.arxiv.org/abs/2608.05720



