betaFeedback

WorksPhysics and Astronomy

Axion polarimetry with parametric readout: photon-number conversion and sensitivity limits

Abstract

We propose a bias-assisted active photon-number conversion scheme for axion-induced polarization rotation in a four-port optical ring cavity with parametric readout. A calibrated real polarization rotation applied before the final optical parametric oscillator (OPO) converts the otherwise quadratic response of the summed output photon number into a linear signal. We derive the resulting photon moments and the extracted-field covariance, retaining the four-port optical transfer, finite axion coherence and linewidth. Our principal phenomenological result is a prospective low-mass sensitivity window at ma=10−18m_a=10^{-18}–10−16 eV10^{-16}\,\mathrm{eV}, extending below the published exclusion bounds included in our comparison, notably the NuSTAR M82 limits. This is a conditional noise-equivalent projection, using the adopted A/σA=1A/σ_A=1 stochastic-power criterion and a parameterized technical-noise budget, not a confidence-level exclusion forecast. As a separate readout result, OPO-based total counting reduces the noise-equivalent coupling by approximately 5%5\% relative to matched selective attenuation in a favorable higher-frequency band; 5%5\% internal loss together with a 0.100.10-rad pump-phase offset leaves a 3.5%3.5\% advantage in the stated example. A coherent input with only the final OPO retains this high-frequency benefit, whereas optimized coherent polarimetry remains more sensitive in the baseline. Our results identify both the operating principle of active number conversion and the stability requirements for a future implementation.

Introduction

Cosmological and astrophysical observations provide evidence for a substantial nonbaryonic dark-matter component, ranging from galactic rotation curves and galaxy clusters to the cosmic microwave background [1, 2, 3, 4, 5, 6, 7]. Additional information comes from galactic substructure and local dynamical measurements [8, 9]. A broad range of particle candidates and detection strategies has been explored [10, 11, 12, 13, 14, 15, 16, 17], alongside alternative approaches based on modified gravity [18].

Among the proposed candidates, axions and axion-like particles are particularly well motivated as light bosonic dark matter [19]. The QCD axion also provides a dynamical solution to the strong-CP problem [20, 21, 22, 23]. More generally, light scalar fields can affect neutrino oscillations [24], while axion-like cosmological fields have been investigated through pulsar timing and galactic dynamics [25, 26]. Other theoretical approaches involve neutrino flavor condensates and wave-dark-matter halos [27, 28, 29]. Further dark-sector scenarios include mirror matter, which motivates neutron–hidden-neutron interferometric searches [30, 31, 32, 33, 34, 35, 36, 37], and light-boson interpretations of anomalous nuclear transitions and related observables [38, 39, 40, 41, 42].

In the present work, we focus on the electromagnetic coupling of an ultralight axion field. When sufficiently light and highly occupied, such a field can be treated as a classical background on laboratory scales. Its interaction with photons is described by Laγ=−gaγaFμνF~μν/4=gaγaE⋅B\mathcal{L}_{a\gamma} = -g_{a\gamma}aF_{\mu\nu}\widetilde{F}^{\mu\nu}/4 = g_{a\gamma}a\mathbf{E}\cdot\mathbf{B}, where aa denotes the axion field and gaγg_{a\gamma} the electromagnetic coupling. A time-dependent background modifies the propagation phases of opposite photon helicities, producing a small oscillatory rotation in a linear polarization basis. This provides the basis for an optical search without an externally applied magnetic field.

Cavity experiments such as DANCE, LIDA and the Axion Dark-Matter Birefringent Cavity (ADBC) exploit this polarization conversion [43, 44, 45, 46, 47]. Their response depends on segment lengths, mirror polarization maps, mode splitting and extraction ports [49, 50, 51] [48]. A fixed circulation direction alone does not determine whether the conversion accumulates. We therefore specify a planar four-mirror geometry and transport both carrier and signal to the detection ports, retaining the two optical sidebands that determine the measured quadrature.

The optical sequence considered here uses a coherent xx-polarized seed and vacuum in yy. A first degenerate optical parametric oscillator (OPO) amplifies the carrier quadrature before the cavity; a phase-matched inverse OPO subsequently acts on the extracted xx polarization [52]. Two spatially separated squeezing operations were previously proposed to detect a scalar dark-matter field [53]. The present pseudoscalar interaction instead encodes the signal as conversion between orthogonal polarizations. The different interaction generator leads to distinct signal and noise properties. Magnetic-field-assisted axion–photon mixing and geometric-phase probes use a different experimental setting [54, 55]. Axion-mediated fermion interactions and neutron interferometry offer other complementary probes [56, 57]. It also distinguishes our probe from signal-polarization squeezed-vacuum injection, used by Martynov and Miao to reduce the detected quadrature noise [58]: the yy input to the interaction remains vacuum in the configuration studied here.

We investigate two physically distinct readout observables. In the first, corresponding to the conventional polarimetric configuration, a downstream electro-optic modulator (EOM) produces a reference field in the selected orthogonal polarization, and the resulting interference term is linear in the axion-induced rotation. This term cancels, however, if the photon numbers of both polarizations are simply added. In the second, which forms our central new construction, we instead place a real, calibrated polarization bias before the inverse OPO and detect both outgoing polarizations. The active transformation then operates away from its number-conversion null, producing a first-order change in their summed photon number. The bias can be implemented as opposite phases of the circular polarizations; a phase delay on one linear polarization alone is not equivalent. The resulting signal is an example of pump-assisted photon-number transduction, not photon creation by the off-resonant axion interaction. This placement and observable distinguish the proposal from an ordinary downstream-EOM interference measurement.

We derive the number response and noise covariance for the complete squeeze–rotate–unsqueeze sequence and evaluate the extracted optical fields using an explicitly specified four-port cavity. For the first observable, our principal phenomenological result is that the polarimetric projection, under the chosen optical resources, local dark-matter density and noise assumptions, potentially probes the mass interval 10−1810^{-18}–10−16 eV10^{-16}\,\mathrm{eV} at couplings below the bounds included in our comparison, notably the NuSTAR M82 limits [59]. The result is a noise-equivalent sensitivity projection under the A/σA=1A/\sigma_A = 1 convention, where A=gaγ2A = g_{a\gamma}^2, rather than a 95% confidence-level exclusion. An experimental realization would have to establish the required noise spectra in the approximately 0.24–24 mHz band.

Turning to the second observable, a separate result concerns total-count readout in a favorable higher-frequency optical band: at matched optical resources, the final OPO can reduce the noise-equivalent coupling by approximately 5% relative to a specified passive selective-attenuation comparator. We test its robustness against internal loss and pump-phase error and show that the final OPO, rather than the first squeezing stage, is responsible for this benefit. These findings do not imply a corresponding advantage for the low-mass polarimetric projection; in fact, the modeled polarimetric OPO configuration is slightly less sensitive than the matched passive comparator. The information bound, exact photon accounting and output-covariance analysis allow both statements to be compared without conflating their observables.

We introduce a downstream-EOM polarimetric arrangement as part of our proposed experimental scheme. The biased total-count variant and the changes required at detection are specified in § 1.6. Section II derives the polarization interaction, and Secs. III–§ 1 develop the optical transformations, polarimetric readout and cavity response. Sections VI–VIII give the resource comparison, sensitivity and noise requirements; Sec. IX compares optical searches. § 1.6 then derives and assesses the linear total-count readout. Canonical and input–output details are collected in the appendices. We use ℏ=c=1\hbar= c = 1 unless SI units are explicitly restored.

Axion–photon Hamiltonian in the off-resonant regime

We first derive the interaction used in the polarimetric analysis. The starting point is the axion–photon Lagrangian density

L=−14FμνFμν−gaγ4aFμνF~μν(1)\mathcal{L}=-\frac{1}{4}F_{\mu\nu}F^{\mu\nu}-\frac{g_{a\gamma}}{4}aF_{\mu\nu}\widetilde{F}^{\mu\nu} \tag*{(1)}

where the axion field is treated semiclassically: the occupation number of the ultralight dark-matter mode is assumed large enough that the laboratory background can be represented by a classical field. Over a time shorter than its coherence time we use the monochromatic form a(t)=a0cos⁡(mat+θa)a(t)=a_0\cos(m_at+\theta_a), with a0=2ρlocal/maa_0=\sqrt{2\rho_{\mathrm{local}}}/m_a, where mam_a is the axion mass, θa\theta_a is the local phase, and ρlocal\rho_{\mathrm{local}} is the local dark-matter energy density. In natural units mam_a is also the angular frequency; in SI units ωa=mac2/ℏ\omega_a=m_ac^2/\hbar. We neglect spatial gradients across the apparatus, ∣∇a∣≪∣a˙∣\lvert\nabla a\rvert\ll\lvert\dot{a}\rvert, so the optical system samples a common axion phase at a given laboratory time. In Coulomb gauge, with A0=0A^0=0 and ∇⋅A=0\nabla\cdot\mathbf{A}=0, one has E=−A˙\mathbf{E}=-\dot{\mathbf{A}} and B=∇×A\mathbf{B}=\nabla\times\mathbf{A}. Up to a total time derivative, and under boundary conditions for which the associated surface term vanishes, the photon Lagrangian is canonically equivalent to Lγ′=12∫d3x(A˙2−B2)+gaγ2a˙(t)∫d3x A⋅BL'_\gamma=\frac{1}{2}\int d^3x\left(\dot{\mathbf{A}}^2-\mathbf{B}^2\right)+\frac{g_{a\gamma}}{2}\dot{a}(t)\int d^3x\,\mathbf{A}\cdot\mathbf{B}. The corresponding Hamiltonian is

H^γ′(t)=H^γ,0−gaγ2a˙(t)∫d3x A^⋅B^.(2)\hat{H}'_\gamma(t)=\hat{H}_{\gamma,0}-\frac{g_{a\gamma}}{2}\dot{a}(t)\int d^3x\,\hat{\mathbf{A}}\cdot\hat{\mathbf{B}}. \tag*{(2)}

Equation (2) is not an additional interaction to be added to the canonical Hamiltonian obtained directly from Eq. (1); the two forms are related by a time-dependent canonical transformation. The explicit derivation is given in Appendix A.

To identify which part of Eq. (2) controls optical polarization, we expand the transverse field in helicity eigenmodes h=±1h=\pm1. Their polarization vectors satisfy ik×ϵh(k)=hkϵh(k)i\mathbf{k}\times\boldsymbol{\epsilon}_h(\mathbf{k})=h k\boldsymbol{\epsilon}_h(\mathbf{k}), with k≡∣k∣k\equiv\lvert\mathbf{k}\rvert. The operator c^kh\hat{c}_{\mathbf{k}h} annihilates a photon of momentum k\mathbf{k} and helicity hh, and N^kh≡c^kh†c^kh\hat{N}_{\mathbf{k}h}\equiv\hat{c}^{\dagger}_{\mathbf{k}h}\hat{c}_{\mathbf{k}h} is the corresponding number operator. After normal ordering,

∫d3x:A^⋅B^:=∑h=±1∫d3k(2π)3[N^kh+12c^khc^−kh+12c^kh†c^−kh†].(3)\int d^{3}x:\hat{\mathbf A}\cdot\hat{\mathbf B}:=\sum_{h=\pm1}\int\frac{d^{3}k}{(2\pi)^{3}}\left[\hat N_{\mathbf k h}+\frac{1}{2}\hat c_{\mathbf k h}\hat c_{-\mathbf k h}+\frac{1}{2}\hat c_{\mathbf k h}^{\dagger}\hat c_{-\mathbf k h}^{\dagger}\right]. \tag*{(3)}

The first term in Eq. (3) shifts the two helicities without changing photon number. The remaining terms annihilate or create photon pairs with opposite momenta and therefore represent a physically different, non-number-conserving channel. In the interaction picture these pair operators carry phases e∓2ikte^{\mp2ikt}; multiplication by the harmonic axion background can make them slowly varying only near the parametric condition ma≃2km_a\simeq2k. The optical regime investigated here is instead far off that resonance and satisfies ma≪k≃ωoptm_a\ll k\simeq\omega_{\mathrm{opt}} and gaγ∣a˙∣≪kg_{a\gamma}|\dot a|\ll k, so that the pair terms are rapidly oscillating and can be removed by a rotating-wave approximation (RWA). The resulting Hamiltonian is

H^γRWA(t)=∑h=±1∫d3k(2π)3[k−hgaγ2a˙(t)]N^kh.(4)\hat H_{\gamma}^{\mathrm{RWA}}(t)=\sum_{h=\pm1}\int\frac{d^{3}k}{(2\pi)^{3}}\left[k-h\frac{g_{a\gamma}}{2}\dot a(t)\right]\hat N_{\mathbf k h}. \tag*{(4)}

For a single optical mode, the axion-dependent part reduces to

H^aRWA(t)=−gaγ2a˙(t)(N^+−N^−).(5)\hat H_{a}^{\mathrm{RWA}}(t)=-\frac{g_{a\gamma}}{2}\dot a(t)\left(\hat N_{+}-\hat N_{-}\right). \tag*{(5)}

This Hamiltonian is diagonal in the circular-polarization basis and generates opposite phases for the two helicities,

c^h(tf)=e−ik(tf−ti)eihΘa(tf,ti)c^h(ti).(6)\hat c_{h}(t_f)=e^{-ik(t_f-t_i)}e^{ih\Theta_a(t_f,t_i)}\hat c_{h}(t_i). \tag*{(6)}

References

  1. [1]V. Trimble, Annu. Rev. Astron. Astrophys. 25, 425–472 (1987).
  2. [2]E. Corbelli and P. Salucci, Mon. Not. R. Astron. Soc. 311, 441–447 (2000).
  3. [3]V. C. Rubin and W. K. Ford, Jr., Astrophys. J. 159, 379 (1970).
  4. [4]V. C. Rubin, W. K. Ford, Jr., and N. Thonnard, Astrophys. J. 238, 471–487 (1980).
  5. [5]D. Clowe et al., Astrophys. J. Lett. 648, L109–L113 (2006).
  6. [6]N. Aghanim et al. (Planck Collaboration), Planck 2018 results. VI. Cosmological parameters, Astron. Astrophys. 641, A6 (2020).
  7. [7]G. Bertone and D. Hooper, History of dark matter, Rev. Mod. Phys. 90, 045002 (2018).DOI
  8. [8]L. Necib, M. Lisanti, and V. Belokurov, Astrophys. J. 874, 3 (2019).
  9. [9]P. F. de Salas and A. Widmark, Dark matter local density determination: Recent observations and future prospects, Rep. Prog. Phys. 84, 104901 (2021).DOI
  10. [10]G. Bertone, D. Hooper, and J. Silk, Particle dark matter: Evidence, candidates and constraints, Phys. Rep. 405, 279–390 (2005).DOI
  11. [11]L. Bergström, Rep. Prog. Phys. 63, 793 (2000).
  12. [12]G. Jungman, M. Kamionkowski, and K. Griest, Phys. Rep. 267, 195–373 (1996).
  13. [13]L. Roszkowski, E. M. Sessolo, and S. Trojanowski, Rep. Prog. Phys. 81, 066201 (2018).
  14. [14]M. Klasen, M. Pohl, and G. Sigl, Prog. Part. Nucl. Phys. 85, 1–32 (2015).
  15. [15]J. Conrad and O. Reimer, Nat. Phys. 13, 224–231 (2017).
  16. [16]M. Schumann, J. Phys. G 46, 103003 (2019).
  17. [17]F. Mayet et al., Phys. Rep. 627, 1–49 (2016).
  18. [18]A. Joyce et al., Phys. Rep. 568, 1–98 (2015).
  19. [19]A. Arvanitaki, S. Dimopoulos, S. Dubovsky, N. Kaloper, and J. March-Russell, String axiverse, Phys. Rev. D 81, 123530 (2010).DOI
  20. [20]R. D. Peccei and H. R. Quinn, CP conservation in the presence of pseudoparticles, Phys. Rev. Lett. 38, 1440 (1977).
  21. [21]R. D. Peccei and H. R. Quinn, Constraints imposed by CP conservation in the presence of pseudoparticles, Phys. Rev. D 16, 1791–1797 (1977).
  22. [22]S. Weinberg, A new light boson?, Phys. Rev. Lett. 40, 223 (1978).DOI
  23. [23]F. Wilczek, Problem of strong P and T invariance in the presence of instantons, Phys. Rev. Lett. 40, 279 (1978).DOI
  24. [24]A. Berlin, Phys. Rev. Lett. 117, 231801 (2016).
  25. [25]I. De Martino, T. Broadhurst, S. H. H. Tye, T. Chiueh, H. Y. Schive, and R. Lazkoz, Phys. Rev. Lett. 119, 221103 (2017).
  26. [26]I. De Martino, T. Broadhurst, S. H. H. Tye, T. Chiueh, H. Y. Schive, and R. Lazkoz, Galaxies 6, 10 (2018).
  27. [27]A. Capolupo, S. Capozziello, G. Pisacane, and A. Quaranta, Phys. Dark Universe 48, 101894 (2025).
  28. [28]A. Capolupo, O. Luongo, and A. Quaranta, Eur. Phys. J. C 86, 154 (2026).
  29. [29]A. Capolupo, I. De Martino, S. Monda, R. Della Monica, and A. Quaranta, Phys. Rev. D 113, 083040 (2026).
  30. [30]T. D. Lee and C. N. Yang, Phys. Rev. 104, 254 (1956).
  31. [31]I. Y. Kobzarev, L. B. Okun, and I. Y. Pomeranchuk, Sov. J. Nucl. Phys. 3, 837–841 (1966).
  32. [32]S. I. Blinnikov and M. Y. Khlopov, Sov. J. Nucl. Phys. 36, 472 (1982).
  33. [33]Z. Berezhiani, Int. J. Mod. Phys. A 19, 3775–3806 (2004).
  34. [34]H. M. Hodges, Phys. Rev. D 47, 456–459 (1993).
  35. [35]R. Foot, Int. J. Mod. Phys. A 29, 1430013 (2014).
  36. [36]A. Capolupo, G. Pisacane, A. Quaranta, and F. Romeo, Phys. Dark Universe 46, 101688 (2024).
  37. [37]A. Capolupo, G. Pisacane, A. Quaranta, and P. Böni, Quantum interferometric probe of neutron–antineutron oscillations, accepted in Phys. Rev. D (19 October 2026), doi:10.1103/fbh9-chx7; arXiv:2602.17218.DOI
  38. [38]A. J. Krasznahorkay et al., Phys. Rev. Lett. 116, 042501 (2016).
  39. [39]A. J. Krasznahorkay et al., J. Phys. Conf. Ser. 1056, 012028 (2018).
  40. [40]J. L. Feng et al., Phys. Rev. Lett. 117, 071803 (2016).
  41. [41]J. L. Feng et al., Phys. Rev. D 95, 035017 (2017).
  42. [42]A. Capolupo, A. Quaranta, and R. Serao, Phys. Dark Universe 47, 101748 (2025).
  43. [43]I. Obata, T. Fujita, and Y. Michimura, Optical ring cavity search for axion dark matter, Phys. Rev. Lett. 121, 161301 (2018).DOI
  44. [44]Y. Oshima et al., First results of axion dark matter search with DANCE, Phys. Rev. D 108, 072005 (2023).DOI
  45. [45]J. Heinze et al., First results of the Laser-Interferometric Detector for Axions (LIDA), Phys. Rev. Lett. 132, 191002 (2024).
  46. [46]H. Liu, B. D. Elwood, M. Evans, and J. Thaler, Searching for Axion Dark Matter with Birefringent Cavities, Phys. Rev. D 100, 023548 (2019).
  47. [47]S. Pandey, E. D. Hall, and M. Evans, First Results from the Axion Dark-Matter Birefringent Cavity (ADBC) Ex- periment. Phys. Rev. Lett. 133, 111003 (2024) [48] C. García-Cely, L. Marisili, A. Ringwald, and A. D. Spector, Polarimetric searches for axion dark matter and high-frequency gravitational waves using optical cavities, Phys. Rev. D 112, 023031 (2025).
  48. [49]H. Takidera et al., Adjusting optical cavity birefringence with wavelength-tunable laser for axion searches, Phys. Rev. D 112, 063048 (2025), doi:10.1103/5pw8-zxmc.DOI
  49. [50]T. Kuramoto, Y. Imai, T. Masuda, Y. Shikano, S. Takatori, and S. Uetake, Analytical study of birefringent cavities for axionlike dark matter search, Phys. Rev. D 113, 055009 (2026).DOI
  50. [51]Q. Rokn, R. Netrval, A. Ejlli, and G. Mueller, Axion Polarimetric Experiment (APE), arXiv:2607.00822 (2026).arxiv.org/abs/2607.00822
  51. [52]C. M. Caves, Quantum-mechanical noise in an interferometer, Phys. Rev. D 23, 1693 (1981).DOI
  52. [53]A. Capolupo, G. Pisacanec, A. Quaranta, and R. Serao, Single arm interferometry to probe the scalar field dark matter, Phys. Rev. D 113, 055027 (2026).arxiv.org/abs/2505.13574
  53. [54]A. Capolupo, I. De Martino, G. Lambiase, and An. Stabile, Axion–photon mixing in quantum field theory and vacuum energy, Phys. Lett. B 790, 427–435 (2019).DOI
  54. [55]A. Capolupo, G. Lambiase, and G. Vitiello, Probing mixing of photons and axion-like particles by geometric phase, Adv. High Energy Phys. 2015, 826051 (2015).DOI
  55. [56]A. Capolupo, G. Lambiase, A. Quaranta, and S. M. Giampaolo, Phys. Lett. B 804, 135407 (2020).
  56. [57]A. Capolupo, S. M. Giampaolo, and A. Quaranta, Eur. Phys. J. C 81, 1116 (2021).
  57. [58]D. Martynov and H. Miao, Quantum-enhanced interferometry for axion searches, Phys. Rev. D 101, 095034 (2020).DOI
  58. [59]O. Ning and B. R. Safdi, Leading Axion-Photon Sensitivity with NuSTAR Observations of M82 and M87, Phys. Rev. Lett. 134, 171003 (2025).DOI
  59. [60]S. L. Braunstein and C. M. Caves, Statistical distance and the geometry of quantum states, Phys. Rev. Lett. 72, 3439 (1994), doi:10.1103/PhysRevLett.72.3439.DOI
  60. [61]M. Takeoka, K. P. Seshadreesan, C. You, S. Izumi, and J. P. Dowling, Fundamental precision limit of a Mach–Zehnder interferometric sensor when one of the inputs is the vacuum, Phys. Rev. A 96, 052118 (2017), arXiv:1705.09506, doi:10.1103/PhysRevA.96.052118.DOI
  61. [62]M. Arik et al. (CAST Collaboration), Phys. Rev. Lett. 107, 261302 (2011).
  62. [63]G. G. Raffelt, Stars as Laboratories for Fundamental Physics (University of Chicago Press, Chicago, 1996).
  63. [64]G. G. Raffelt, Astrophysical axion bounds, in Axions, Lecture Notes in Physics Vol. 741, pp. 51–71 (Springer, Berlin, 2008).
  64. [65]K. Altenmüller et al. (CAST Collaboration), New Upper Limit on the Axion–Photon Coupling with an Extended CAST Run with a Xe-Based Micromegas Detector, Phys. Rev. Lett. 133, 221005 (2024).DOI
  65. [66]C. P. Salemi et al., Search for Low-Mass Axion Dark Matter with ABRACADABRA-10 cm, Phys. Rev. Lett. 127, 081801 (2021), doi:10.1103/PhysRevLett.127.081801.DOI
  66. [67]C. S. Reynolds et al., Astrophysical limits on very light axion-like particles from Chandra grating spectroscopy of NGC 1275, Astrophys. J. 890, 59 (2020), doi:10.3847/1538-4357/ab6a0c.DOI
  67. [68]A. Abramowski et al. (H.E.S.S. Collaboration), Constraints on axionlike particles with H.E.S.S. from the irregularity of the PKS 2155-304 energy spectrum, Phys. Rev. D 88, 102003 (2013), doi:10.1103/PhysRevD.88.102003.DOI
  68. [69]A. Payez et al., Revisiting the SN1987A gamma-ray limit on ultralight axion-like particles, JCAP 02, 006 (2015), doi:10.1088/1475-7516/2015/02/006.DOI
  69. [70]H. Fujimoto, Y. Oshima, M. Ando, T. Fujita, Y. Michimura, K. Nagano, and I. Obata, Dark Matter Axion Search with riNg Cavity Experiment (DANCE): Design and Development of Auxiliary Cavity for Simultaneous Resonance of Linear Polarizations, J. Phys.: Conf. Ser. 2156, 012172 (2021).DOI
  70. [71]Q.-J. Huang, B. Wang, J.-J. Wei, and X.-F. Wu, Probing extragalactic ultralight axion dark matter with decade-long blazar optical polarimetry of 1ES 1959+650, Phys. Rev. Lett. 137, 181001 (2026).DOI
  71. [72]H. Yu et al., Photon counting for axion interferometry, Phys. Rev. D 109, 095042 (2024).DOI
  72. [73]E. Armengaud et al., Physics potential of the International Axion Observatory (IAXO), JCAP 06, 047 (2019).

Paper details

vlnc:W_axgfxsh7
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 11

downloads · 1

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents