Measurement of directional muon beams generated at the Berkeley Lab Laser Accelerator

Abstract

We present the detection of directional muon beams produced using a PW laser at the Lawrence Berkeley National Laboratory. The muon source is a multi-GeV electron beam generated in a 30 cm laser plasma accelerator interacting with a high-Z converter target. The GeV photons resulting from the interaction are converted into a high-flux, directional muon beam via pair production. By employing scintillators to capture delayed events, we were able to identify the produced muons and characterize the source. Using theoretical knowledge of the muon production process combined with simulations that are in excellent agreement with the experiments, we demonstrate that the multi-GeV electron beams produce GeV-scale muons in numbers far exceeding those from cosmic background. Laser-plasma-accelerator-based muon sources can therefore enhance muon imaging applications thanks to their compactness, directionality, and high yields, which reduce the exposure time by orders of magnitude compared to cosmic ray muons. Using the Geant4-based simulation code we developed to gain insight into the experimental results, we can design future experiments and applications based on LPA-generated muons.

Introduction

Muons beams have attracted considerable attention in recent years because of their unique properties and potential applications across various fields of physics. However, production of muon beams for fundamental physics research, for instance a future TeV-class muon-muon collider 1 or the Muon g−2g-2 experiment at Fermilab 2, is challenging and it is currently done by accelerating high-energy proton beams in large-scale facilities, colliding them with fixed targets and collecting the created mesons that will eventually decay into muons 3.

Given the large size of the accelerators, proton-based muon production is not suitable for imaging applications because neither the source nor the typical imaging samples can be transported. In fact, thanks to their considerable penetration power, muons are used for non-destructive imaging of large or concealed objects 4, which must be performed on-site. For such reason, currently the only available source of muons for imaging applications are the cosmic rays, which, when interacting with the Earth’s atmosphere, generate showers of particles, including muons, that are accessible in any unshielded place on the planet. The incoming muon flux on the Earth’s surface can be approximated as dN/dΩdSdt≈70cos⁡2(θ) m−2s−1sr−1dN/d\Omega dSdt \approx70\cos^2(\theta)\ \mathrm{m}^{-2}\mathrm{s}^{-1}\mathrm{sr}^{-1} 5, where θ\theta is the angle from the zenith, along which the flux is maximum. For most of the imaging applications, such a muon flux requires months of exposure before a statistically significant signal is accumulated. For instance, when imaging objects along the plane of earth’s surface, the muon flux is reduced to dN/dSdtdt≪0.1−1 m−2s−1dN/dSdtdt \ll0.1 - 1\ \mathrm{m}^{-2}\mathrm{s}^{-1}, due to the limited angular aperture of the detectors. Therefore, muography via cosmic ray muons can generally be applied only to objects that are immobile over long periods of time. A notable and fascinating example of their use was the discovery of a hidden chamber in Khufu’s Pyramid (Great Pyramid of Giza) [6, 7]. They also enable investigating the magmatic chambers of active volcanoes [8], blast furnaces [9], and nuclear waste [10, 11, 12]. These are only a few examples of the available applications and implementations of the muography technique. For a more general review see Refs. [13, 14] and references therein.

Laser plasma accelerators (LPAs) provide an alternative source of muon beams as a byproduct of the collision of an LPA-generated electron beam with a high-Z target [15], a possibility supported by some numerical studies [16, 17]. Several laboratories have demonstrated generation of 100s MeV to multi-GeV-class electron beams in targets up to tens of centimeters using different techniques, with representative examples in Refs. [18, 19, 20, 21, 22, 23, 24, 25, 26], providing enough energy for muon generation via pair-production. Pair-produced muons are very suitable for muography as they are characterized by high-energy, of the order of the initial electron energy, and low divergence and they are generated directly into the solid target6 where the interaction is taking place. Currently available high-power laser systems, operating at repetition rates between 1 and 10 Hz, enable producing LPA-based directional muon beams with yields orders of magnitude higher than cosmic rays, thus providing substantial speedups to applications that typically require months of exposure times. A next generation kHz LPA [27] could further improve this factor by three orders of magnitude, opening new avenues to the use of muons in imaging large objects in only a few minutes. A LPA-based muon source provides the essential characteristics that are needed for imaging applications together with the advantages of a compact source that can be deployed on the imaging site. Laser technologies currently in development, such as fiber lasers or high-efficiency solid state lasers, show the potential of realizing such a compact and deployable laser system in the future [27].

In this paper we present the generation and measurement of GeV muons using the BErkeley Laboratory Laser Accelerator (BELLA) Facility at the Lawrence Berkeley National Laboratory. In Sec. II we give an overview of the relevant muon production mechanisms, highlighting the characteristics of the generated muons. In Sec. III we present the setup for the electron beam generation and the production and measurements of muons. In Sec. IV we analyze the results of the experiments and show how muons are identified. We demonstrate that the electron beams interacting with the shielding configuration of our laboratory generate muons via different mechanism and that we can spatially separate them into a directional and a quasi-isotropic source. Simulations that reproduce the experimental measurements are presented in Sec. V, where we investigate in detail the muon production process in the experimental cave. Sec. VI presents the conclusions of our work and the next steps.

Mechanisms of Muon Production in High-Z Materials

When a high-energy electron traveling in a solid converter target is deviated by an atomic nucleus, it emits high energy photons, or Bremsstrahlung radiation [28]. The energy distribution of the Bremsstrahlung photons is characterized by an exponential-like decay, extending to the same maximum energy as the initial electron [28, 29, 30]. The angle of emission is confined within a cone of angular aperture ΔθB≃1/γe\Delta\theta_B \simeq1/\gamma_e, where γe\gamma_e is the Lorentz factor of the radiating electron. Bremsstrahlung photons that interact with the background atomic nuclei can be converted into pairs of charged leptons (a particle and an antiparticle) via the Bethe-Heitler process if their energy is Eγ≥2mpc2E_\gamma\geq2m_pc^2, where mpm_p is the particle (lepton) mass, and cc the speed of light in vacuum. The cross-section for the Bethe-Heitler production is proportional to the inverse of the particle mass squared [31], i.e., σBH∝1/mp2\sigma_{BH} \propto1/m_p^2, and the generated particles are emitted along the photon propagation direction, thus resulting in a particle shower

confined within an angle ≲ΔθB\lesssim\Delta\theta_B. The energy spectrum of the products follows from the Bremsstrahlung distribution, with a maximum energy Emax⁡=Eγ−2mpc2E_{\max} = E_\gamma- 2m_pc^2, due to energy-momentum conservation.

Given that e+e−e^+e^- pairs, i.e., positron-electron, are the most probable products of the Bethe-Heitler process, Bremsstrahlung radiation induced by the propagation of an electron beam into high-Z targets (e.g., tungsten or lead) has been used as a source of positron beams for conventional acceleration for several decades [29] and it has been extensively investigated in experiments.

Both the Bremsstrahlung and the Bethe-Heitler emissions develop over a characteristic radiation length X0X_0. The radiation length is defined as the length over which an electron propagating in the material loses all but 1/e1/e of its initial energy, which corresponds to 7/97/9 of the mean free path for Bethe-Heitler emission. The value of X0X_0 depends on the atomic composition of the material and on its density. For high-Z materials, its value ranges from millimeters to centimeters [29].

Simulated energy spectra of muons generated via pair production and decay from a 10 GeV electron beam

Figure 1. Simulated energy spectra of muons generated via pair production and decay from a 10 GeV electron beam propagating in a 2.1 cm-thick tungsten target. The distributions are normalized per initial primary electron. The solid black and red lines correspond to the total yield of pair produced and decay muons, respectively. The dashed black and red lines present the spectrum of respectively pair and decay produced muons within 100 mrad. Simulation results show that effectively all pair produced muons with E=4E = 4 GeV are confined within 100 mrad.

The properties of photon decay into μ+μ−\mu^+\mu^- pairs are analogous to the e+e−e^+e^- pair creation, but the cross section is reduced by a factor R=me2/mμ2=2.34×10−5R = m_e^2/m_\mu^2 = 2.34 \times10^{-5}. For this reason, it has not been subject to the same detailed experimental investigations and applications.

In addition to the Bethe-Heitler mechanism, the interactions of electrons with targets also lead to the production of pions (π±\pi^\pm) which subsequently decay into muons (the average pion lifetime is τπ±=2.6×10−8\tau_{\pi^\pm} = 2.6 \times10^{-8} s). In particular, main sources of pions in the material are the processes γ+p→π++n\gamma+ p \to\pi^+ + n, γ+n→π−+p\gamma+ n \to\pi^- + p, and γ+N→π++π−+N\gamma+ N \to\pi^+ + \pi^- + N, where the γ\gamma rays interacting with the background protons (pp), neutrons (nn), and nucleons (N=p,N = p, n)n) are the ones produced via Bremsstrahlung [15]. Analogous processes apply to kaon creation, although with a lower probability due to the higher kaon mass. Both pions and kaons decay into muons, therefore we will refer to the muon flux resulting from this mechanism as coming from a more general meson decay. The total cross section for muon production through meson decay in a high-ZZ target is higher than the one for the Bethe-Heitler μ+μ−\mu^{+}\mu^{-} process. However, given the large meson rescattering and absorption cross sections, the resulting meson flux is weaker and not well collimated in a thick target [15]. Therefore, we expect some contributions to the number of muons from meson decay at large angles. Moreover, due to the relativistic dilation of the proper time, only low energy mesons decay in the vicinity of the converter, resulting in a sharp cut-off of the spectrum at high energies. It is possible to produce high energy muons via meson decay, but it requires ∼km\sim\mathrm{km}-scale separations from the converter.

Fig. 1 shows simulated energy spectra, normalized per initial primary electron, of muons generated respectively via pair production and meson decay from a monochromatic 10 GeV electron beam propagating in a 2.1 cm-thick tungsten target. The simulations were performed using the Geant4 toolkit for simulation of the propagation of particles through matter [32, 33, 34], including solely the monoenergetic electron beam and tungsten target in the setup geometry. The solid black line is the spectrum of muons generated via Bethe-Heitler integrated over 4π4\pi, while the dashed black line is the spectrum of muons selected within a 100 mrad cone, which effectively contains all the muons produced with energies E≳4E \gtrsim4 GeV. The red line is the energy spectrum of muons generated via meson decay over the 4π4\pi angle. Muons from meson decay with energies ≥1\ge1 GeV are statistically negligible within 100 mrad, as shown by the dashed red line.

We show the effect of target thickness on the number of muons produced per initial electron in Figure 2, with results from Geant4 simulations. The pair production only depends on the normalized thickness, i.e., the number of radiation lengths traversed, and does not show significant differences between different materials. The number of pair-produced muons is maximum between (6−10) X0(6 - 10)\,X_0 for an initial 10 GeV electron beam, similarly to what is expected for positrons [29], and slowly decreases for larger thicknesses due to the high penetration power of muons. We point out that the processes discussed here are single-particle interactions and, therefore, the number of muons produced is linearly proportional to the incoming electron beam charge.

Simulated yields of pair produced muons as a function of target thickness for different materials

Figure 2. Simulated yields of pair produced muons within 100 mrad along the primary 10 GeV electron beam axis for different materials and their thicknesses expressed in radiation lengths X0X_0. Normalization to a single primary electron is applied. The plot shows a saturation of the yield at ∼6X0\sim6X_0 and independence of the target material. Beyond 10X010X_0, muon production is substantially suppressed, and ionization energy losses prevent low-energy muons from escaping the target. This leads to a reduction in the observed yield, reflecting the decreasing contribution of low-energy muons to the total yield.

In this section we reviewed different mechanisms for muon production, highlighting their characteristics. Pair production yields a directional and collimated muon beam, while meson decay generates a quasi-isotropic muon flux. In the next sections we will show how the interaction of an electron beam with the shielding configuration of our laboratory combines these processes. The electron beam dump suppresses the meson propagation, absorbing all but muon produced via pair production, while mesons are generated in other high-ZZ elements along the beam path, which do not possess the same filtering power, and eventually decay into a quasi-isotropic background of low-energy muons.

Experimental Setup

The experiments described here were carried out in an experimental campaign to generate and measure muons at the BELLA center between December 2023 and January 2024. The laser-plasma accelerator was driven using the BELLA PW laser [35]. A detailed description of the accelerator can be found in [25] and a schematic of the experiment can be found in Figure 3. The drive laser duration was ∼40\sim40 fs and was focused to a spot-size of w0=(53±1) μmw_0=(53\pm1)\,\mu\mathrm{m}, at the entrance of a 30-cm-long hydrogen gas jet [25, 36]. The measured laser energy was E≃21E \simeq21 J. Before the arrival of the LPA drive laser, an auxiliary pulse focused by an axicon lens was used to ionize and form a plasma channel by hydrodynamic expansion [37] of an optical field-ionized plasma [38, 39, 40]. The measured axial density was n0≈1×1017 cm−3n_0 \approx1\times10^{17}\,\mathrm{cm}^{-3}. Ionization injection was triggered by a 1% nitrogen dopant extending over a region of the channel of length LdopL_{\mathrm{dop}}. For Ldop≈12L_{\mathrm{dop}}\approx12 cm, it was possible to achieve single, quasi-monoenergetic electron bunches with peak energy up to 9.2 GeV and charge extending beyond 10 GeV [25].

Schematic top-view of the experimental setup

Figure 3. Schematic top-view of the experimental setup (not to scale). The laser drive and channel-forming beams, on the left, are coupled into a 30 cm gas-jet, generating the electron beam. After a ∼10\sim10 m drift, the electron beam reaches the magnetic spectrometer and is then unloaded on the electron beam dump, where it produces the muons. The scintillators are placed in the measurement room, behind the concrete wall, in two possible configurations. Each configuration includes a pair of scintillators close to each other (spaced a few cm), which were placed either along the beam axis, i.e., “on-axis” configuration, or ≃1\simeq1 m to the side of the beam axis, “off-axis” configuration. The scintillators are ≃10\simeq10 cm away behind the concrete wall.

For this experiment, Ldop≈30L_{\mathrm{dop}} \approx30 cm, and the accelerator was run in a stable condition with electron beam spectra show in Figure 4. The measured charge was in the range Q≃45−250Q \simeq45 - 250 pC, with an average Q≃80Q \simeq80 pC, integrated over energies above 2 GeV, and exponential-like energy spectra with tails extending to ∼8\sim8 GeV were observed.

Electron energy spectra

Figure 4. The solid black line is the electron energy spectrum (averaged over 42 shots) used for muon generation experiments in December 2023. The beam is characterized by continuous, exponential-like spectrum with a tail extending to ∼8\sim8 GeV. Its integrated charge for energies E≥2E \geq2 GeV is Q≃80Q \simeq80 pC. The blue and red dotted lines are two samples of single-shot electron spectra of the generated beams. The dip around 1.9 GeV is due to a physical gap in the magnetic spectrometer screens.

These high-energy electrons are passed through a 1.08 T momentum analyzing dipole magnet (which deflects the electron beam downward towards the floor). We specifically refer to the 4 GeV electron trajectory axis through and past the magnet as the “deflected reference axis”.

The deflected electrons are then stopped in a dedicated electron beam dump composed of 40.5 cm of lead, 1 m of steel, and a final 1.80 m block of concrete. After the electron beam dump, a 90 cm concrete wall separates the experimental cave from the measurement room. The measurement room, located directly behind the wall in the beam direction propagation, is where the detectors were placed. The length LL of the electron beam dump, expressed in units of radiation lengths, is L≃142L \simeq142, calculated using X0,Pb=0.56X_{0,\mathrm{Pb}} = 0.56 cm, X0,Steel=1.76X_{0,\mathrm{Steel}} = 1.76 cm, and X0,Concrete=11.6X_{0,\mathrm{Concrete}} = 11.6 cm. The large thickness suppresses the propagation of secondary particles, such as photons, pions, kaons, electrons, and positrons. Muons only lose energy via ionization with a rate per unit density of about 2 MeV cm2^{2}/g [41]. Energy losses via Bremsstrahlung are negligible and are only relevant for muons with energies E≳1E \gtrsim1 TeV. This allows high energy muons to propagate through the beam dump and escape from its rear, pass through the wall, and finally reach the measurement room, where they can be detected. From our simulations and from analytical estimates using the stopping power provided in Ref. [41], and considering the full beam dump and the wall, we obtain that a muon loses about EL≲4E_L \lesssim4 GeV via ionization when reaching the measurement room. Ionization losses act as a filter for the low energy muons, as muons generated with energies E<ELE < E_L are absorbed during their propagation. Energy losses via ionization are energy-independent in the energy range of interest for our experiment, so the estimate holds for all the muons produced in the interaction. These losses must be taken into account when designing a muon source as they typically define the muon penetration range into the imaged sample. Muons propagating in the material are subject to scattering, which increases the final muon beam divergence. An estimate of the final angle accumulated by a muon of momentum pp, that is with normalized velocity β=v/c=p/(mμcγ)\beta= v/c = p/(m_\mu c\gamma), via multiple scattering after propagating a distance dd in a material with radiation length X0X_0 can be obtained using the approximate formula [42]

σθ2=(13.6 MeVpβ)2dX0[1+0.038log⁡(dβ2X0)]2(1)\sigma_\theta^2 = \left(\frac{13.6\,\mathrm{MeV}}{p\beta}\right)^2 \frac{d}{X_0} \left[1 + 0.038 \log\left(\frac{d}{\beta^2 X_0}\right)\right]^2 \tag*{(1)}

derived from Moliere’s scattering theory [43]. Eq. (1) neglects energy losses during the propagation, but we can apply it using the average energy of a muon to roughly estimate the final angular aperture of the beam. For instance, for muons with an initial energy E0=4E_0 = 4 GeV the final rmsrms divergence is on the order of σθ≃100\sigma_\theta\simeq100 mrad. Given a total propagation length from the creation point to the measurement room, i.e., the beam dump and the wall, of about L≃4L \simeq4 m, the expected beam rmsrms size behind the wall is σr≃50\sigma_r \simeq50 cm.

Detectors

A scintillator-based radiation detector is employed for beam pulse monitoring and muon identification behind the beam dump along the aforementioned deflected reference axis. The setup consists of two panels of scintillating plastic (1 cm thick Polystyrene, total area of 500 cm2^2/panel) each optically coupled to a photomultiplier tube (PMT). Each PMT signal is fed into a shaping amplifier and, along with a logic trigger indicating the laser pulse timing, read out by a 50 MHz Analog-to-Digital Converter (ADC). A Nuclear Instrumentation Module logic unit giving the ‘AND’ of both channel discriminators initiates a 50 μ\mus readout window of the ADC, which is saved for offline analysis. The readout is activated when both scintillators detect a signal at approximately the same time, for instance when they are crossed by the initial burst of particles generated in the electron beam interaction with the shielding, which defines the t=0t = 0 time. The trigger timestamp was subsequently verified during the post-processing analysis, matching it with the recorded timestamp of each LPA shot. The time resolution of particle interaction in the scintillator is limited by the period between samples of the ADC, which is 20 ns.

Figure 3 shows the experimental apparatus behind the beam dump. The scintillator pair is arranged in two different orientations used to monitor the muon production at different angles from the beam direction. In particular, we identify an “on-axis” configuration, in which the pair is along the deflected reference axis with the two scintillators separated along this axis” for the particles (in absence of a downward deflecting magnetic field) would be approximately 1 m higher, but this scenario was not experimentally studied in this campaign.

Muons in the 1–10 GeV energy range are minimum ionizing particles, however, below this range, their energy loss per unit distance rises sharply [41]. Muons (antimuons) of sufficiently low energy, on the order of 20 MeV, can be stopped by the layers of plastic scintillator, and their decay to an electron (positron) and two neutrinos within the plastic can subsequently be observed with an average lifetime τμ=2.2 μs\tau_\mu= 2.2\,\mu\mathrm{s}. Stopped muon decays are identified in the experimental apparatus via the ionization from the daughter electron, which manifests as a second light pulse following the initial trigger. By studying the decay time distribution, a positive muon identification can be made by checking consistency with the muon lifetime.

Experimental Results

During the experiment, we operated the laser at a frequency of 0.1 Hz. The radiation generated by the accelerated electron beam unloaded on the electron beam dump served as a trigger to activate the scintillators. Of the muons produced in the interaction, some reach the detectors with an energy range 0≤E≲200 \le E \lesssim20 MeV. These muons stop in the Polystyrene until they decay, generating a delayed signal. We assigned the time t=0t = 0 to each trigger

and collected the subsequent signals into the histogram shown in Figure 5. The dataset refers to a roughly two hour period, i.e., 760 shots, in which we measured electron beams with the average spectrum shown in Figure 4, i.e., with Q=80Q = 80 pC for E>2E > 2 GeV. By fitting the histogram with the exponential function f(t)=Aexp⁡(−t/τ)+Cf(t) = A\exp(-t/\tau) + C, we obtain the lifetime τ=2.24±0.50 μs\tau= 2.24 \pm0.50\ \mu\mathrm{s} and a constant background C=3.21±0.97C = 3.21 \pm0.97. The measurement of the decay time is compatible with the decay of stopped muons, i.e., τμ=2.2 μs\tau_\mu= 2.2\ \mu\mathrm{s}. Given that the total number of muon candidates recorded is Ntot=165N_{\mathrm{tot}} = 165, and that we used 12 bins for the histogram, the number of detected muons is Nμ=126±12N_\mu= 126 \pm12, while the number of background events is Nb=39±12N_b = 39 \pm12. Recorded muon candidates have been verified by matching the incoming electron beam timestamp with the detection timestamp, previously synchronized. We deem the contribution of cosmic muons negligible because the average flux of muons from cosmic rays from all angles at sea level is about F≃147 m−2s−1F \simeq147\ \mathrm{m}^{-2}\mathrm{s}^{-1} [5], uniform in time, i.e., the expected number of muons hitting the scintillator surface Σ≃0.05 m2\Sigma\simeq0.05\ \mathrm{m}^2 within a Δt=35 μs\Delta t = 35\ \mu\mathrm{s} interval after a laser shot is ≃3×10−4\simeq3 \times10^{-4}. Measurements performed without operating the LPA, i.e., triggered by cosmic ray arrival, confirmed the expected value of flux of cosmic muons reported in [5]. Using simulations, we

Count of time delay from the initial trigger

Figure 5. Count of time delay from the initial trigger, t=0t = 0. Error bars are obtained under a Poisson distribution. By fitting with the exponential function f(t)=Aexp⁡(−t/τ)+Cf(t) = A\exp(-t/\tau) + C, that is assuming signal from muon decay (black solid line) and a constant background (blue dashed line), we obtain τ=2.24±0.50 μs\tau= 2.24 \pm0.50\,\mu\mathrm{s} and C=3.21±0.97C = 3.21 \pm0.97.

τ\tau [μs\mu\mathrm{s}]CC
Total2.24±0.502.24 \pm0.503.21±0.973.21 \pm0.97
Off-axis2.39±0.542.39 \pm0.542.70±0.892.70 \pm0.89
On-axis1.74±0.661.74 \pm0.660.58±0.320.58 \pm0.32

caption: Lifetime τ\tau and background CC resulting from fitting the histogram of the total, off-axis, and on-axis event, respectively.

:::

identified the cause of the background as being generated by the photons emitted in the neutron capturing in the shielding. After the initial burst of radiation generated by the incoming electron beam, characterized by a Bremsstrahlung spectrum very localized in time, i.e., Δt≲1 ns\Delta t \lesssim1\ \mathrm{ns}, slower particles, such as neutrons, travel through the experimental cave and reach the concrete wall, behind the beam dump, on the μs\mu\mathrm{s} to ms\mathrm{ms} time scales. When neutrons are stopped in the concrete wall, they generate photons with energies related to characteristic levels of atomic excitation [44] of, for instance, Silicon and Oxygen, the elements that account for the highest fraction of the concrete mass. The produced MeV photons hit the scintillators, scattering on its electrons and generating a signal in the PMTs. The presence of such neutrons is confirmed by the neutron monitors inside and outside the experimental cave.

In Figure 6 we separate the same muon counting dataset already presented in Figure 5 in on-axis and off-axis measurements. These correspond to muon decay times measured with the scintillators placed on the beam axis (“on-axis” configuration) and ≃1 m\simeq1\ \mathrm{m} to its side (“off-axis” configuration), respectively, both

Count of time delay histograms for off-axis and on-axis scintillators

Figure 6. Count of time delay from the initial trigger, t=0t = 0, separated for scintillators on the beam propagation axis (bottom panel) and off-axis (top panel). The data included in this figure is the same as the one shown in Figure 5, but we are presenting the muon count on and off-axis in two separate plots to highlight their difference. Error bars are obtained under a Poisson distribution. The exponential fits result in τ=2.39±0.54 μs\tau= 2.39 \pm0.54\ \mu\mathrm{s} and C=2.70±0.89C = 2.70 \pm0.89, and τ=1.74±0.66 μs\tau= 1.74 \pm0.66\ \mu\mathrm{s} and C=0.58±0.32C = 0.58 \pm0.32 for the off-axis and on-axis case respectively.

axis counting histograms, we obtain τ=2.39±0.54 μs\tau= 2.39 \pm0.54\ \mu\mathrm{s} and C=2.70±0.89C = 2.70 \pm0.89 and τ=1.74±0.66 μs\tau= 1.74 \pm0.66\ \mu\mathrm{s} and C=0.58±0.32C = 0.58 \pm0.32, respectively, from which we estimate the number of stopped muons as Nμoff=114±11N_\mu^{\mathrm{off}} = 114 \pm11 and Nμon=14±3N_\mu^{\mathrm{on}} = 14 \pm3. We obtain the off-axis and on-axis probabilities of a muon detection per shot per scintillator as Poff=(14.4±1.4)%P^{\mathrm{off}} = (14.4 \pm1.4)\% and Pon=(1.9±0.5)%P^{\mathrm{on}} = (1.9 \pm0.5)\% respectively, where we used the number of shots Nshotsoff=386N_{\mathrm{shots}}^{\mathrm{off}} = 386 and Nshotson=374N_{\mathrm{shots}}^{\mathrm{on}} = 374. As we will see in the next section, such a large muon count away from the beam reference axis can be explained by taking into account the contribution of muons generated in the decay of mesons.

We have shown in this section that the analysis of the scintillator signals revealed unambiguous detection of muons generated by the electron beams. In the next section, we will show that computational modeling of the experiment reproduces the measurements and identifies the source the muon count far from the beam’s reference axis.

Simulation Results

We performed numerical simulations of the muon production using a custom code based on the Geant4 toolkit. Our code implements an accurate model of the beam dump and of the wall between the beam dump and the measurement room. In addition, we included two of the high-ZZ laser diagnostics, a wedge and power meter, as well as the magnetic spectrometer since they are placed along the beam path, even though they do not interact with well-aligned electron beams. The magnetic spectrometer is turned on with a field 1.08 T1.08\,\mathrm{T} and we verified the correct implementation by checking the bending of some reference trajectories. We implemented a sensitive detector, a detector in Geant4 that is a virtual screen behind the wall to record the passage of every particle. For each particle hitting the detector, its information, e.g., phase space, detection time, and generating process, are saved. Moreover, we implemented copies of the scintillators in order to model their response within the same simulation framework, that is therefore fully self-consistent. More details on the code can be found in the appendix. We initialized the electron beam according to its average spectral profile, shown in Figure 4, limited to energies E>2 GeVE > 2\,\mathrm{GeV}, i.e., with a total charge Q=80 pCQ = 80\,\mathrm{pC}, and with a rms divergence 0.1 mrad0.1\,\mathrm{mrad}. The rms divergence was obtained by Particle-in-Cell (PIC) simulations and further confirmed in the measurements, which showed a divergence in the range 0.1−0.5 mrad0.1 - 0.5\,\mathrm{mrad}. We point out that the exact value does not affect the overall description of the process, as long as it remains small, i.e., <1 mrad< 1\,\mathrm{mrad}, since emission angle of secondary particles is dominated by the electron scattering, with a typical angle ≥100 mrad\ge100\,\mathrm{mrad}. Figure 7 shows the simulation setup, including, from right to left, following the beam path, the two laser diagnostics, the magnetic spectrometer, the electron beam dump, and the large concrete wall behind the electron beam dump. The width and height of the wall coincide with the spatial extent of the Geant4 geometry, therefore it is not possible for a particle to travel around the wall and reach the detectors, not shown in the figure, behind the wall itself.

Scheme of the simulation setup implemented in Geant4

Figure 7. Scheme of the simulation setup implemented in Geant4 to model the experiment. From right to left, the arrow shows the beam direction. The two disks are laser diagnostics with some high-ZZ layers. The black box is the magnetic spectrometer and, following, there is the beam dump. On the left, the concrete wall that separates the experimental cave from the measurement room, where the scintillators are placed. The red lines are electron trajectories, the blue ones positrons. Positive and negative muons are respectively cyan and yellow. We filtered neutrons and photons for the sake of visualization.

In Figure 7, red trajectories are the electrons, including the primary ones coming from the direction of the arrow, while blue trajectories represent the positrons. The cyan and yellow trajectories are, respectively, μ+\mu^{+} and μ−\mu^{-}, which are created in the early lead region of the dump and propagate through it, reaching the measurement room. For the sake of visualization, we removed photon and neutron trajectories from the picture. As explained in Sec. II, we expect the majority of high energy photons to be produced in the beam direction via Bremsstrahlung. Neutrons are produced in the high-ZZ layers of the beam dump and emitted isotropically in space. Electrons with energies ranging from keV to MeV are extracted via ionization by the muon passage and, in the majority of cases, quickly reabsorbed. Electrons extracted close to the back of the wall can have enough energy to escape and propagate into the measurement room. Such electrons are represented in Figure 7 by the red trajectories that generate from the muons ones.

We show in Figure 8 energy spectra of muons, resulting from Geant4 simulations, sampled at 6X06X_{0} inside the electron beam dump, i.e., ≃5 cm\simeq5\,\mathrm{cm} inside the lead block (black line) and on the detector in the measurement room (red line). Muons predominantly lose energy via ionization when propagating through dense materials. Traversing the electron beam dump and the wall results in EL≲4 GeVE_{L} \lesssim4\,\mathrm{GeV} muon energy loss before the detection point. This can be verified by integrating the equation of motion of a muon moving in a straight trajectory through the shielding configuration, using the stopping power tabulated in Ref. [41]. In a broad energy range 1 GeV≤E≤10 GeV1\,\mathrm{GeV} \leq E \leq10\,\mathrm{GeV} the stopping power is substantially energy-independent, thus the calculation applies to all the generated muons.

Muon energy spectra obtained via Geant4 simulations

Figure 8. Muon energy spectra obtained via Geant4 simulations of a perfectly aligned electron beam with energy shown in Figure 4 and 80 pC80\,\mathrm{pC} charge. The black line is the energy spectrum sampled 6 radiation lengths into the dump. The red line is the spectrum on the virtual screen behind the external wall. The difference between the spectra is due to the ionization losses, which roughly account for EL≲4 GeVE_{L} \lesssim4\,\mathrm{GeV}.

Figure 9 shows the expected flux of muons obtained from an 80 pC80\,\mathrm{pC} electron beam with the initial energy spectrum shown in Figure 4. The beam center before the spectrometer is in x=0x = 0, y=0y = 0, and the axis y=−1.4 my = -1.4\,\mathrm{m} corresponds to the floor. Due to the bending of the incoming electron beam in the magnetic field of the spectrometer, the average vertical position of the muons on the detector is y=−0.45 my = -0.45\,\mathrm{m}. The muon flux at x=0x = 0, y=−0.45 my = -0.45\,\mathrm{m} is F=73.5±9.1 m−2shot−1F = 73.5 \pm9.1\,\mathrm{m}^{-2}\mathrm{shot}^{-1}. Simulations show that the number of muons with an angle from the beam axis θ≤θ0=100 mrad\theta\leq\theta_0 = 100\,\mathrm{mrad} impinging on a surface Σ=2×2 m2\Sigma= 2 \times2\,\mathrm{m}^{2} placed in front of the source is NμLPA≳20 shot−1N_{\mu}^{\mathrm{LPA}} \gtrsim20\,\mathrm{shot}^{-1}. These muons are, for instance, the ones of interest for muography applications along the earth’s surface plane. In comparison, based on the approximated description of the muon flux from cosmic rays, we can estimate the arrival rate of such muons on the same surface and within the same acceptance as NμCR≃147sin⁡3(θ0)Σ≃0.5 s−1N_{\mu}^{\mathrm{CR}} \simeq147\sin^{3}(\theta_0)\Sigma\simeq0.5\,\mathrm{s}^{-1}. Assuming LPAs generating ≳100 pC\gtrsim100\,\mathrm{pC} beams and operating at 1 Hz1\,\mathrm{Hz}, accessible to most currently-available high-power laser systems, laser-plasma generated electron beams provide more than 40 times the muons than cosmic rays along the plane of the earth’s surface. Development of high-repetition-rate laser drivers can boost this factor by orders of magnitude. The plot shows a negligible flux of muons outside a cone of narrow aperture σθ≃100 mrad\sigma_\theta\simeq100\,\mathrm{mrad}, which agrees with the expectation of muons generated via Bethe-Heitler. In order to explain the detection of muons away from the beam’s reference axis, we need to take into account the pointing fluctuations of the electron beam, characterized during the experiment with an rms value σθ≃3 mrad\sigma_\theta\simeq3\,\mathrm{mrad}. Despite this value is negligible compared to the aperture of the photon and muon emission cone, it is enough for the electron beam to interact with the laser diagnostics placed before the magnetic spectrometer, which have an angular acceptance of 1.2 mrad1.2\,\mathrm{mrad}, and with the magnetic spectrometer itself. Since all these elements are made of high-ZZ materials, i.e., aluminum, fused silica, and steel, a beam passing through them produces muons via Bethe-Heitler process and mesons from photoproduction, as illustrated in Sec. II. Mesons do not encounter the same amount of material as when they are produced deep inside the electron beam dump and therefore they are not reabsorbed, propagating quasi-isotropically in the experimental cave. Once these mesons decay, the low energy muons that are produced do not need to traverse the electron beam dump and have enough energy to propagate through the concrete wall and be detected by the scintillators. This is demonstrated in Figure 10, where we show the simulated flux of muons per beam, assuming an initial beam deviation of 1.5 mrad1.5\,\mathrm{mrad} from the reference axis. The central shade in the picture resembles the shape of the magnetic spectrometer and the beam dump, which demonstrates that some mesons are produced and decay into muons before the spectrometer, resulting in a radiography of the two elements onto the virtual detector. Inside the shaded area, around the point x=0x = 0, y=−0.45 my = -0.45\,\mathrm{m}, we can see the collimated contribution to the flux of the muons generated via Bethe-Heitler, similar to the well-aligned case shown in Figure 9. The flux at x=0x = 0, y=−0.45 my = -0.45\,\mathrm{m} is

Muon flux behind the concrete wall for a perfectly aligned electron beam

Figure 9. Muon flux behind the concrete wall computed using Geant4 for a perfectly aligned beam. The calculation assumes an initial Q=80 pCQ = 80\,\mathrm{pC} electron beam perfectly aligned with the ideal beam’s reference axis, i.e., it does not interact with metal parts in the laser diagnostics and the magnetic spectrometer chassis. The muon flux at x=0x = 0, y=−0.45 my = -0.45\,\mathrm{m} is F=73.5±9.1 m−2shot−1F = 73.5 \pm9.1\,\mathrm{m}^{-2}\mathrm{shot}^{-1}. An inspection of the muons shows that all of them are generated via Bethe-Heitler. The detection plane is ≃4 m\simeq4\,\mathrm{m} downstream from the muon source.

Muon flux behind the concrete wall for a misaligned electron beam

Figure 10. Muon flux behind the concrete wall computed using Geant4 for a misaligned electron beam. The calculation assumes an initial Q=80 pCQ = 80\,\mathrm{pC} electron beam, with an initial misalignment 1.5 mrad1.5\,\mathrm{mrad} from the beam’s reference propagation axis. The shift is sufficient for the electron beam to interact with the metal in laser diagnostics and the magnetic spectrometer chassis. The central region, close to the beam’s reference axis, is mainly composed of muons generated via Bethe-Heitler. The flux at x=0x = 0, y=−0.45 my = -0.45\,\mathrm{m} is F=24.9±9.1 m−2shot−1F = 24.9 \pm9.1\,\mathrm{m}^{-2}\mathrm{shot}^{-1} and its characteristic vertically oblong shape around this point resembles the well-aligned beam case in Figure 9. Muons generated in meson decay contribute to a quasi-isotropic flux, visible on the detector far from the beam’s reference axis. The detection plane is ≃4 m\simeq4\,\mathrm{m} downstream from the muon source.

F=24.9±9.1 m−2shot−1F = 24.9 \pm9.1\ \mathrm{m}^{-2}\mathrm{shot}^{-1}. We notice an elongated region of high muon flux on the x=0x = 0 axis, for y≳1 my \gtrsim1\ \mathrm{m}. Simulations identify these muons as being generated via Bethe-Heitler. The interaction of the electron beam with the high-ZZ elements before the magnetic spectrometer produces positive particles, such as positrons and antimuons, which are bent upward by the magnetic field. Due to the geometry of our shielding, as shown in Figure 7, these positive particles only traverse a small fraction of the beam dump, which results in a higher muon flux. Outside of the shaded area, muons from meson decay contribute to a uniform, quasi-isotropic flux. The lack of filtering power provided by the electron beam dump explains the higher background noise recorded in off-axis measurements. Photons generated in the interaction and in the neutron capturing inside the shielding, can traverse the wall away from the beam dump, scattering on the electrons of the scintillators and triggering signal.

The scintillator models implemented in the code allow us to directly count the muons that stop and decay into them, reproducing the signal we obtained in the experiment. In order to approximate the effect of the pointing fluctuations of the electron beams, we consider the results obtained by simulating a linear combination of well-aligned and misaligned beams. Given that the angular fluctuations were characterized during the experiment as being gaussian with σθ≃3 mrad\sigma_\theta\simeq3\ \mathrm{mrad}, the number of beams contained within −1.2 mrad≤θ≤1.2 mrad-1.2\ \mathrm{mrad} \leq\theta\leq1.2\ \mathrm{mrad}, that is the acceptance of the optical elements before the dump, determining a well-aligned beam, is ∼30%\sim30\%. We can see in Figure 11 the simulated probability of counting a muon per LPA beam in detectors placed on the y=−1 my = -1\ \mathrm{m} axis, matching their placement in the experiment, as a function of the detector horizontal position, for a combination of 30% aligned beams and 70% misaligned beams.

Simulated percentage of LPA shots with a positive muon count in a scintillator as a function of detector horizontal position

Figure 11. Simulated percentage of LPA shots with a positive muon count in a scintillator in function of the horizontal position of the scintillator. Results are obtained using a model of the scintillator implemented in Geant4. The probabilities at x=0x = 0 and x=1 mx = 1\ \mathrm{m} agree well with the values measured in the experiment. Scintillators are placed 1 m1\ \mathrm{m} below the beam height. Simulation results are obtained by (weighted) averaging of two simulation scenarios: the case of well-aligned electron beams (with <1.2 mrad<1.2\ \mathrm{mrad} pointing deviation from ideal reference axis, observed during 30% of the LPA shots) and misaligned electron beams at >1.2 mrad>1.2\ \mathrm{mrad} pointing (70% of the LPA shots).

In Figure 11 the simulated probability of counting a muon per LPA beam in detectors placed on the y=−1 my = -1\ \mathrm{m} axis, matching their placement in the experiment, as a function of the detector horizontal position, for a combination of 30% aligned beams and 70% misaligned beams. The results from the simulations agree quite well with the experiment. We computed a probability of a muon stopping in a scintillator Poff=(13.6±2.7)%P^{\mathrm{off}} = (13.6 \pm2.7)\% for a scintillator placed 1 m1\ \mathrm{m} to the side of the deflected reference axis, and Pon=(4.0±2.4)%P^{\mathrm{on}} = (4.0 \pm2.4)\% for a scintillator placed in the beam’s reference axis. Recalling the results shown in Sec. IV, the measured values for those probabilities are Poff=(14.4±1.4)%P^{\mathrm{off}} = (14.4 \pm1.4)\% and Pon=(1.9±0.5)%P^{\mathrm{on}} = (1.9 \pm0.5)\% respectively.

Scintillator-based detectors cannot measure the muon flux directly. The majority of muons crosses them within a short temporal window Δt≲1 ns\Delta t \lesssim1\ \mathrm{ns} following the LPA beams, together with secondary particles. This prevents a direct muon counting because the PMT is saturated and it is not possible to distinguish between each different charged particles triggering a signal. However, the agreement between simulations and measurements on the number of stopped muons both on- and off-axis, i.e., the low energy fraction of the incoming ones, provides insight into the produced flux, which simulations predict being on the order of F≳10 m−2shot−1F \gtrsim10\ \mathrm{m}^{-2}\mathrm{shot}^{-1} for the electron beams produced in our experimental run. We have shown that the flux is the result of two spatially separated contributions: a central region, around the beam axis, of directional, high-energy muons generated via pair production and an off-axis region mainly composed by lower energy non-directional muons generated via meson decay.

The present work shows that LPAs provide unique advantages as a source of directional muon beams. Their ultra-high accelerating gradients produce electron beams within very compact, i.e., 10s of cm scales, acceleration lengths. These are orders of magnitude smaller compared to the storage rings used to accelerate protons that produce muons via the pion decay channels. Such electron beams possess an outstanding capability of producing directional muon beams. The performance of the LPA source can be substantially improved by increasing the initial electron energy due to a conjunction of multiple effects. The properties of the Bremsstrahlung cascade are such that the yield of particles from pair production for an optimized target scales roughly linearly with the initial beam energy [29], although the scaling could be either sub- or super-linear depending on the target geometry and the exact energy range [17]. Moreover, higher initial energies result in a more collimated muon beam, i.e., higher flux, and a higher maximum muon energy. We compared simulations of the muons produced by the electron beam obtained in our experiment to the ones produced by a higher energy beam achievable, for instance, by staging two LPA sections. We used the PIC code INF&RNO [45, 46] to obtain the final electron beam distribution. As an example, we considered a realistic setup based on the current 40 J BELLA facility where each stage is powered by a 19 J laser beam. PIC simulations produced a 18.2 GeV beam with 26 pC of charge and small energy spread, which we used as input in our Geant4 code to understand how the muon production scales at higher energy. Figure 12 shows a comparison between the simulated muon spectra, integrated over the entire wall surface, resulting from the interaction with the shielding configuration of the average 80 pC beam obtained in our experiment, labeled “experiment”, and of the 26 pC monochromatic beam with E=18.2E = 18.2 GeV produced in simulations of staging acceleration, respectively. The plot demonstrates that by increasing the source energy, the overall quality of the muon source improves. Muons produced via pair production extend to higher energies and, even accounting for the energy losses induced by the shielding, they possess the strong penetrating power required for imaging applications.

Spectra of muons behind the wall

Figure 12. Spectra of muons behind the wall, obtained using Geant4, integrated over the whole surface and differentiated by the muon generating process. The black lines show the spectrum of pair-produced muons, the red lines show muons generated via meson decay. The solid lines refer to a monochromatic, 18.2 GeV, 26 pC electron beam obtained in simulations of staging LPAs using two 19 J laser pulses, with BELLA laser parameters. The dotted lines refer to the spectra obtained using the experimental electron beam with spectrum as in Figure 4. Increasing the electron beam energy improves the source quality by producing a higher yield of directional and high energy muons.

These results motivate us to design future experiments and applications based on E>10E > 10 GeV electron beams. While for the present work we relied on the electron-to-muon conversion offered by the shielding, it is possible to design optimized converter targets, as shown in Figure 2, where the muon flux can be maximized and the energy losses minimized. The optimal energy of the electron beam is determined by the imaging sample considered, due to the aforementioned effect of ionization losses. We note that, in the configuration used here, scintillators are not suitable for imaging applications. Such applications rely on tracking individual muon trajectories before and after the sample and typically demand muons with energies anywhere from ∼100\sim100 MeV to beyond 1 TeV, the exact requirement being set by the desired penetration depth. Detectors used for tracking should therefore be capable of registering every muon that arrives, irrespective of its energy. In our experiment, however, we characterized the muon source by counting delayed signals in the scintillator panels, a method that selects only a small fraction of low-energy muons. Nonetheless, the results suggest that LPAs could provide a practical muon source for imaging applications requiring penetration depths achievable with muons below a few tens of GeV.

With the Geant4-based simulation tool that we developed, we can investigate the properties of the resulting beam and design an appropriate detection scheme to pick up signals from the high-energy muons before and after the imaging sample. It is also possible to equip our code with imaging reconstruction algorithms that enable start-to-end simulations, i.e., from the electron beam to the final imaging result, which would let us tailor the design of a converter target and the required shielding.

Conclusions

In this paper, we presented the implementation of a high-energy and directional muon source based on laser-plasma accelerated electron beams obtained using the BELLA PW laser. The electron beams were generated via ionization injection of an unlocalized dopant and accelerated using a 21 J laser pulse, which yielded beams with broad energy spectra reaching up to 8 GeV, low divergence, and pointing fluctuations of 3 mrad [25]. When such beams impinged on the electron beam dump or grazed other high-Z elements along their path, muons were generated via pair production and meson decay. We identified N=126±12N = 126 \pm12 muon detections during two hours operation, sampled from the low energy part of the generated beam that stopped into the scintillators, and we characterized the resulting muon flux via simulations and experiments, noting that the two production mechanisms could be spatially distinguished. Muons from pair production are characterized by a high-energy, up to the energy of the initial electrons, a low-divergence, and a strong directionality along the incoming beam path. These characteristics make them very suitable for imaging applications as the illumination of a target can be optimized to maximize their flux and their tracking in and out from the target itself. The energy and number of pair produced muons scales with the initial electron beam energy and charge and can be tuned to fit the application requirements.

Muons from decay of mesons make up the majority of muons near the converter. They are characterized by a quasi-isotropic angular distribution and by a sharp cutoff at high energies, therefore their contribution to the muon flux in the forward direction is very weak. It is not desirable to rely on them in applications that require high fluxes at a distance and strong penetrating power. In our experiment and simulations we showed that muons generated via meson decay can be detected away from the beam path, where they are not filtered by the electron beam dump.

LPA-accelerated electron beams are generated over compact acceleration lengths and possess outstanding properties to generate muon yields orders of magnitude higher than what is naturally available with cosmic rays. In particular, while the average number of cosmic muons through a meter-scale imaging setup parallel to the earth’s surface plane with an aperture θ=100\theta= 100 mrad is NμCR≤1 s−1N_{\mu}^{CR} \leq1\ \mathrm{s}^{-1}, LPA beams with energies and charges in the range, respectively, E∼(1−10)E \sim(1 - 10) GeV and Q∼(10−500)Q \sim(10 - 500) pC produce NμLPA≳102 shot−1N_{\mu}^{LPA} \gtrsim10^{2}\ \mathrm{shot}^{-1} through the same imaging setup. Near future LPA and laser technology developments, e.g., staged acceleration and pulse delivery at the kHz repetition rate, can boost this property by orders of magnitude. Using the same simulation tools we used to understand the experimental results, we can design future muography application based on high-energy electron beams and detectors suitable for muon scattering image reconstruction.

This experiment proves the feasibility of a muon source based on LPA-generated electron beams. It is an important result to establish the readiness of the LPA technology for applications and to motivate the development of high-repetition-rate and transportable laser systems, which could push applications like muography to unprecedented capabilities, offering muon yields orders of magnitude higher than cosmic rays.

Acknowledgments

The authors would like to thank Adam Davis, Brian Dorney, Francesca Kukral, Hans Malik, and Scott Wolin of Northrop Grumman Corporation, Ryan Heller of the Lawrence Berkeley National Laboratory for the insightful discussions, and Zachary Eisentraut, Mark Kirkpatrick, Federico Mazzini, Nathan Ybarrolaza, Derrick McGrew, Paul Centeno, Teo Maldonado Mancuso, Art Magana, Joe Riley, Mackinley Kath, and Chetanya Jain of the Lawrence Berkeley National Laboratory for technical support on experiments. D.T. is grateful to Sarah Schröder and Stepan Bulanov for the enlightening conversations. This work was supported by the Defense Advanced Research Projects Agency (DARPA), the Director, Office of Science, Office of High Energy Physics, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231, and used the computational facilities at the National Energy Research Scientific Computing Center (NERSC).

Modeling the experiments with a Geant4-based code

We performed simulations of the experimental campaign with a custom application developed using Geant4. The code defines the geometry of the experimental chamber retaining shapes and materials of the included elements. The implementation includes two laser diagnostics, a wedge and a power meter, the magnetic spectrometer, the beam dump with all its internal layers and the wall. The electron beam can be initialized freely using macros, and its energy spectrum, initial position and direction and its divergence can be chosen arbitrarily. The code uses the predefined QGSP_BERT_EMZQGSP\_BERT\_EMZ physics package. It includes a high precision model for neutron propagation, that we used to understand background noise, and for the electromagnetic interaction. In order for the code to account for the muon pair production, the process has to be manually activated via a macro command, because it is not included in the predefined physics list by default. The code uses biasing to improve the statistical significance of the simulations. In particular, we rely on the splitting of muon pairs and pion decays to increase the number of produced muons. During our time using and benchmarking the code we updated several Geant4 versions, but the results presented in this paper are obtained with Geant4 v11.2. While the version v11.0 returns consistent values, we noticed during our investigation that version v11.1 does not yield the same results for muon production. The issue was addressed in subsequent releases (see Geant4 v11.2 Release Notes).

The code is equipped with several diagnostics, including sensitive detectors in the dump that track the development of the Bremsstrahlung cascade, a sensitive detector behind the wall that captures all the particles leaving the chamber and a model of the scintillators. We save the phase space and some relevant information about particles that cross them that generate most of the plots shown in the paper. The scintillators are constructed using the same material and size as the real detectors and they are programmed to return particles that stop within their boundaries, from which we can extract the number of muons detected.

References

  1. [5]Particle Data Group, R. L. Workman, V. D. Burkert, V. Crede, E. Klempt, U. Thoma, L. Tiator, K. Agashe, G. Aielli, B. C. Allanach, C. Amsler, M. Antonelli, E. C. Aschenauer, D. M. Asner, H. Baer, S. Banerjee, R. M. Barnett, L. Baudis, C. W. Bauer, J. J. Beatty, V. I. Belousov, J. Beringer, A. Bettini, O. Biebel, K. M. Black, E. Blucher, R. Bonventre, V. V. Bryzgalov, O. Buchmuller, M. A. Bychkov, R. N. Cahn, M. Carena, A. Ceccucci, A. Cerri, R. S. Chivukula, G. Cowan, K. Cranmer, O. Cremonesi, G. D’Ambrosio, T. Damour, D. de Florian, A. de Gouvêa, T. DeGrand, P. de Jong, S. Demers, B. A. Dobrescu, M. D’Onofrio, M. Doser, H. K. Dreiner, P. Eerola, U. Egede, S. Eidelman, A. X. El-Khadra, J. Ellis, S. C. Eno, J. Erler, V. V. Ezhela, W. Fetscher, B. D. Fields, A. Freitas, H. Gallagher, Y. Gershtein, T. Gherghetta, M. C. Gonzalez-Garcia, M. Goodman, C. Grab, A. V. Gritsan, C. Grojean, D. E. Groom, M. Gruenewald, A. Gurtu, T. Gutsche, H. E. Haber, M. Hamel, C. Hanhart, S. Hashimoto, Y. Hayato, A. Hebecker, S. Heinemeyer, J. J. Hernández-Rey, K. Hikasa, J. Hisano, A. Höcker, J. Holder, L. Hsu, J. Huston, T. Hyodo, A. Ianni, M. Kado, M. Karliner, U. F. Katz, M. Kenzie, V. A. Khoze, S. R. Klein, F. Krauss, M. Kreps, B. Kriz̆an, B. Krusche, Y. Kwon, O. Lahav, J. Laiho, L. P. Lellouch, J. Lesgourgues, A. R. Liddle, Z. Ligeti, C.-J. Lin, C. Lippmann, T. M. Liss, L. Littenberg, C. Lourenço, K. S. Lugovsky, S. B. Lugovskу, A. Lusiani, Y. Makida, F. Maltoni, T. Mannel, A. V. Manohar, W. J. Marciano, A. Masoni, J. Matthews, U.-G. Meiβner, I.-A. Melzer-Pellmann, M. Mikhasenko, D. J. Miller, D. Milstead, R. E. Mitchell, K. Mönig, P. Molaro, F. Moortgat, M. Moscovik, K. Nakamura, M. Narain, P. Nason, S. Navas, A. Nelles, M. Neubert, P. Nevksi, Y. Nir, K. A. Olive, C. Patrignani, J. A. Peacock, V. A. Petrov, E. Pianori, A. Pich, A. Piepke, F. Pietropaolo, A. Pomarol, S. Pordes, S. Profumo, A. Quadt, K. Rabbertz, J. Rademacker, G. Raffelt, M. Ramsey-Musolf, B. N. Ratcliff, P. Richardson, A. Ringwald, D. J. Robinson, S. Roesler, S. Rolli, A. Romaniouk, L. J. Rosenberg, J. L. Rosner, G. Rybka, M. G. Ryskin, R. A. Ryutin, Y. Sakai, S. Sarkar, F. Sauli, O. Schneider, S. Schönen, K. Scholberg, A. J. Schwartz, J. Schwiening, D. Scott, F. Seckow, U. Seljak, V. Sharma, S. R. Sharpe, V. Shiltsev, G. Signorelli, M. Silari, F. Simon, T. Sjöstrand, P. Skands, T. Skwarnicki, G. F. Smoot, A. Soffer, M. S. Sozzi, S. Spanier, C. Spiering, A. Stahl, S. L. Stone, Y. Sumino, M. J. Syphers, F. Takahashi, M. Tanabashi, J. Tanaka, M. Taševský, K. Terao, K. Terashi, J. Terning, R. S. Thorne, M. Titov, N. P. Tkachenko, D. R. Tovey, K. Trabelsi, P. Urquijo, G. Valencia, R. Van de Water, N. Varelas, G. Venanzoni, L. Verde, I. Vivarelli, P. Vogel, W. Vogelsang, V. Vorobyev, S. P. Wakely, W. Walkowiak, C. W. Walter, D. Wands, D. H. Weinberg, E. J. Weinberg, N. Wermes, M. White, L. R. Wiencke, S. Willocq, C. G. Wohl, C. L. Woody, W.-M. Yao, M. Yokoyama, R. Yoshida, G. Zanderighi, G. P. Zeller, O. V. Zenin, R.-Y. Zhu, S.-L. Zhu, F. Zimmermann, and P. A. Zyla, Review of Particle Physics, Progress of Theoretical and Experimental Physics 2022, 083C01 (2022).
  2. [6]K. Morishima, M. Kuno, A. Nishio, N. Kitagawa, Y. Manabe, M. Moto, F. Takasaki, H. Fujii, K. Satoh, H. Kodama, K. Hayashi, S. Odaka, S. Procureur, D. Attié, S. Bouteille, D. Calvet, C. Filosa, P. Magnier, I. Mandjavidze, M. Riallott, B. Marini, P. Gable, Y. Date, M. Sugiura, Y. Elshayeb, T. Elnady, M. Ezzy, E. Guerriero, V. Steiger, N. Serikoff, J.-B. Mouret, B. Charlès, H. Helal, and M. Tayoubi, Discovery of a big void in Khufu’s Pyramid by observation of cosmic-ray muons, Nature 552, 386 (2017), publisher: Nature Publishing Group.DOI
  3. [7]A. Nishio, K. Morishima, K. Kuwabara, and M. Nakamura, Development of Nuclear Emulsion Detector for Muon Radiography, Physics Procedia 26th International Conference on Nuclear Tracks in Solids (ICNTS26) Kobe, Japan 15th – 19th September 2014, 80, 74 (2015).DOI
  4. [8]H. Tanaka, K. Nagamine, N. Kawamura, S. N. Nakamura, K. Ishida, and K. Shimomura, Development of a two-fold segmented detection system for near horizontally cosmic-ray muons to probe the internal structure of a volcano, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 507, 657 (2003).DOI
  5. [9]X. Hu, L. S. Ökvist, E. Åström, F. Forsberg, C. Checchia, G. Bonomi, I. Calliari, P. Calvini, A. Donzella, E. Faraci, F. Gonella, J. Klinger, D. Pagano, A. Rigoni, P. Zanut-tigh, P. Ronchese, M. Urbani, S. Vanini, A. Zenoni, and G. Zumerle, Exploring the Capability of Muon Scattering Tomography for Imaging the Components in the Blast Furnace, ISIJ International 58, 35 (2018).DOI
  6. [10]H. Fujii, K. Hara, S. Hashimoto, F. Ito, H. Kakuno, S. Kim, M. Kochiyama, K. Nagamine, A. Suzuki, Y. Takada, Y. Takahashi, F. Takasaki, and S. Yamashita, Performance of a remotely located muon radiography system to identify the inner structure of a nuclear plant, Progress of Theoretical and Experimental Physics 2013, 073C01 (2013).
  7. [11]H. Fujii, K. Hara, K. Hayashi, H. Kakuno, H. Kodama, K. Nagamine, K. Sato, K. Sato, S.-H. Kim, A. Suzuki, K. Takahashi, and F. Takasaki, Detection of on-surface objects with an underground radiography detector system using cosmic-ray muons, Progress of Theoretical and Experimental Physics 2017, 053C01 (2017).DOI
  8. [12]G. Jonkmans, V. N. P. Anghel, C. Jewett, and M. Thompson, Nuclear waste imaging and spent fuel verification by muon tomography, Annals of Nuclear Energy 53, 267 (2013).DOI
  9. [13]S. Vanini, P. Calvini, P. Checchia, A. Rigoni Garola, J. Klinger, G. Zumerle, G. Bonomi, A. Donzella, and A. Zenoni, Muography of different structures using muon scattering and absorption algorithms, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences 377, 20180051 (2018), publisher: Royal Society.DOI
  10. [14]S. Procureur, Muon imaging: Principles, technologies and applications, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment Radiation Imaging Techniques and Applications, 878, 169 (2018).DOI
  11. [15]A. I. Titov, B. Kämpfer, and H. Takabe, Dimuon production by laser wakefield accelerated electrons, Physical Review Special Topics - Accelerators and Beams 12, 111301 (2009), publisher: American Physical Society.DOI
  12. [16]B. S. Rao, J. H. Jeon, H. T. Kim, and C. H. Nam, Bright muon source driven by GeV electron beams from a compact laser wakefield accelerator, Plasma Physics and Con- trolled Fusion 60, 095002 (2018), publisher: IOP Publishing.
  13. [17]L. Calvin, P. Tomassini, D. Doria, D. Martello, R. M. Deas, and G. Sarri, Laser-driven muon production for material inspection and imaging, Frontiers in Physics 11, 10.3389/fphy.2023.1177486 (2023), publisher: Frontiers.DOI
  14. [18]C. Amiculasei, T. Ha, S. Yoffe, L. Labun, S. Milton, E. McCary, M. M. Spinks, H. J. Quevedo, O. Z. Labun, R. Sain, A. Hannasch, R. Zgadzaj, I. Pagano, J. A. Franco-Altamirano, M. L. Ringuette, E. Gaul, S. V. Luedtke, G. Tiwari, B. Ersfeld, E. Brunetti, H. Ruhl, T. Ditmire, S. Bruce, M. E. Donovan, M. C. Downer, D. A. Jaroszynski, and B. M. Hegelich, The acceleration of a high-charge electron bunch to 10 GeV in a 10-cm nanoparticle-assisted wakefield accelerator, Matter and Radiation at Extremes 9, 014001 (2023).
  15. [19]J. Faure, Y. Glinec, A. Pukhov, K. S. Kiselev, S. Gordienko, E. Lefebvre, J.-P. Rousseau, F. Burgy, and V. Malka, A laser–plasma accelerator producing monoenergetic electron beams, Nature 431, 541 (2004), number: 7008 Publisher: Nature Publishing Group.pubmed.ncbi.nlm.nih.gov/15457253
  16. [20]C. G. R. Geddes, C. Toth, J. van Tilborg, E. Esarey, C. B. Schroeder, D. Bruhwiler, C. Niet er, J. Cary, and W. P. Leemans, High-quality electron beams from a laser wakefield accelerator using plasma-channel guiding, Nature 431, 538 (2004), number: 7008 Publisher: Nature Publishing Group.pubmed.ncbi.nlm.nih.gov/15457252
  17. [21]W. Leemans, A. Gonsalves, H.-S. Mao, K. Nakamura, C. Benedetti, C. Schroeder, C. Tóth, J. Daniels, D. Mittelberger, S. Bulanov, J.-L. Vay, C. Geddes, and E. Esarey, Multi-GeV Electron Beams from Capillary-Discharge-Guided Subpetawatt Laser Pulses in the Self-Trapping Regime, Physical Review Letters 113, 245002 (2014), publisher: American Physical Society.pubmed.ncbi.nlm.nih.gov/25541775
  18. [22]S. P. D. Mangles, C. D. Murphy, Z. Najmudin, A. G. R. Thomas, J. L. Collier, A. E. Dangor, E. J. Divall, P. S. Foster, J. G. Gallagher, C. J. Hooker, D. A. Jaroszynski, A. J. Langley, W. B. Mori, P. A. Norreys, F. S. Tsung, R. Viskup, B. R. Walton, and K. Krushelnick, Monoenergetic beams of relativistic electrons from intense laser–plasma interactions, Nature 431, 535 (2004), number: 7008 Publisher: Nature Publishing Group.pubmed.ncbi.nlm.nih.gov/15457251
  19. [23]X. Wang, R. Zgadzaj, N. Fazel, Z. Li, S. A. Yi, X. Zhang, W. Henderson, Y.-Y. Chang, R. Korzekwa, H.-E. Tsai, C.-H. Pai, H. Quevedo, G. Dyer, E. Gaul, M. Martinez, A. C. Bernstein, T. Borger, M. Spinks, M. Donovan, V. Khudik, G. Shvets, T. Ditmire, and M. C. Downer, Quasi-monoenergetic laser-plasma acceleration of electrons to 2 GeV, Nature Communications 4, 1988 (2013), number: 1 Publisher: Nature Publishing Group.DOI
  20. [24]A. Gonsalves, K. Nakamura, J. Daniels, C. Benedetti, C. Pieronek, T. de Raadt, S. Steinke, J. Bin, S. Bulanov, J. van Tilborg, C. Geddes, C. Schroeder, C. Tóth, E. Esarey, K. Swanson, L. Fan-Chiang, G. Bagdasarov, N. Bobrova, V. Gasilo v, G. Korn, P. Sasorov, and W. Leemans, Pettawatt Laser Guiding and Electron Beam Acceleration to 8 GeV in a Laser-Heated Capillary Discharge Waveguide, Physical Review Letters 122, 084801 (2019), publisher: American Physical Society.
  21. [25]A. Picksley, J. Stackhouse, C. Benedetti, K. Nakamura, H. Tsai, R. Li, B. Miao, J. Shrock, E. Rockafellow, H. Milchberg, C. Schroeder, J. van Tilborg, E. Esarey, C. Geddes, and A. Gonsalves, Matched Guiding and Controlled Injection in Dark-Current-Free, 10-GeV-Class, Channel-Guided Laser-Plasma Accelerators, Physical Review Letters 133, 255001 (2024), publisher: American Physical Society.DOI
  22. [26]J. Shrock, E. Rockafellow, B. Miao, M. Le, R. Hollinger, S. Wang, A. Gonsalves, A. Picksley, J. Rocca, and H. Milchberg, Guided Mode Evolution and Ionization Injection in Meter-Scale Multi-GeV Laser Wakefield Accelerators, Physical Review Letters 133, 045002 (2024), publisher: American Physical Society; E. Rockafellow, B. Miao, J. E. Shrock, A. Sloss, M. S. Le, S. W. Hancock, S. Zaphedpour, R. C. Hollinger, S. Wang, J. King, P. Zhang, J. Šišma, G. M. Grittani, R. Versaci, D. F. Gordon, G. J. Williams, B. A. Reagan, J. J. Rocca, and H. Milchberg, Development of a high charge 10 GeV laser electron accelerator, Physics of Plasmas 32, 053102 (2025); B. Miao, J. Shrock, L. Feder, R. Hollinger, J. Morrison, R. Nedbailo, A. Picksley, H. Song, S. Wang, J. Rocca, and H. Milchberg, Multi-GeV Electron Bunches from an All-Optical Laser Wakefield Accelerator, Physical Review X 12, 031038 (2022), publisher: American Physical Society.DOI
  23. [27]L. Kiani, T. Zhou, S.-W. Bahk, J. Bromage, D. Bruhwiler, E. M. Campbell, Z. Chang, E. Chowdhury, M. Downer, Q. Du, E. Esarey, A. Galvanauskas, T. Galvin, C. Häfner, D. Hoffmann, C. Joshi, M. Kanskar, W. Lu, C. Menoni, M. Messerly, S. B. Mirov, M. Palmer, I. Pogorelsky, M. Polyansky, E. Power, B. Reagan, J. Rocca, J. Rothenberg, B. E. Schmidt, E. Sistrunk, T. Spinka, S. Tochitsky, N. Vafaei-Najafabadi, J. v. Tilborg, R. Wilcox, J. Zuegel, and C. Geddes, High average power ultrafast laser technologies for driving future advanced accelerators, Journal of Instrumentation 18 (08), T08006, publisher: IOP Publishing.
  24. [28]J. Jackson, Classical electrodynamics, Vol. 3 (Wiley New York etc., 1962).
  25. [29]A. W. Chao, K. H. Mess, and others, Handbook of accelerator physics and engineering (World scientific, 2013).
  26. [30]Y.-S. Tsai, Pair production and bremsstrahlung of charged leptons, Reviews of Modern Physics 46, 815 (1974).DOI
  27. [31]H. Bethe, W. Heitler, and P. A. M. Dirac, On the stopping of fast particles and on the creation of positive electrons, Proceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character 146, 83 (1997), publisher: Royal Society.
  28. [32]S. Agostinelli, J. Allison, K. Amako, J. Apostolakis, H. Araujo, P. Arce, M. Asai, D. Axen, S. Banerjee, H. Barrand, F. Behner, L. Bellagamba, J. Boudreau, L. Broglia, A. Brunengo, H. Burkhardt, S. Chauvie, J. Chuma, R. Chytracek, G. Cooperman, G. Cosmo, P. Degtyarenko, A. Dell’Acqua, G. Depaola, D. Dietrich, R. Enami, A. Feliciello, C. Ferguson, H. Fesefeldt, G. Folger, F. Foppiano, A. Forti, S. Garelli, S. Giani, R. Giannitrapani, D. Gibin, J. J. Gómez Cadenas, I. González, G. Gracia Abril, G. Greeniaus, W. Greiner, V. Grichine, A. Grossheim, S. Guatelli, P. Gumplinger, R. Hamatsu, K. Hashimoto, H. Hasui, A. Heikkinen, A. Howard, V. Ivanchenko, A. Johnson, F. W. Jones, J. Kallenbach, N. Kanaya, M. Kawabata, Y. Kawaguti, S. Kelner, P. Kent, A. Kimura, T. Kodama, R. Kokoulin, M. Kossov, H. Kurashige, E. Lamanna, T. Lampén, V. Lara, V. Lefebure, F. Lei, M. Liendl, W. Lockman, F. Longo, S. Magni, M. Maire, E. Medernach, K. Minamimoto, P. Mora de Freitas, Y. Morita, K. Murakami, M. Nagamatu, R. Nartallo, P. Nieminen, T. Nishimura, K. Ohtsubo, M. Okamura, S. O’Neale, Y. Oohata, K. Paech, J. Perl, A. Pfeiffer, M. G. Pia, F. Ranjard, A. Rybin, S. Sadilov, E. Di Salvo, G. Santin, T. Sasaki, N. Savvas, Y. Sawada, S. Scherer, S. Sei, V. Sirotenko, D. Smith, N. Starkov, H. Stoecker, J. Sulkimo, M. Takahata, S. Tanaka, E. Tcherniaev, E. Safai Tehrani, M. Tropeano, P. Truscott, H. Uno, L. Urban, P. Urban, M. Verderi, A. Walkden, W. Wander, H. Weber, J. P. Wellisch, T. Wenaus, D. C. Williams, D. Wright, T. Yamada, H. Yoshida, and D. Zschiesche, Geant4—a simulation toolkit, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 506, 250 (2003).
  29. [33]J. Allison, K. Amako, J. Apostolakis, H. Araújo, P. Arce Dubois, M. Asai, G. Barrand, R. Capra, S. Chauvie, R. Chytracek, G. Cirrone, G. Cooperman, G. Cosmo, G. Cuttone, G. Daquino, M. Donszelmann, M. Dressel, G. Folger, F. Foppiano, J. Generowicz, V. Grichine, S. Guatelli, P. Gumplinger, A. Heikkinen, I. Hrivnacova, A. Howard, S. Incerti, V. Ivanchenko, T. Johnson, F. Jones, T. Koi, R. Kokoulin, M. Kossov, H. Kurashige, V. Lara, S. Larsson, F. Lei, O. Link, F. Longo, M. Maire, A. Mantero, B. Mascialino, I. McLaren, P. Mendez Lorenzo, K. Minamimoto, K. Murakami, P. Nieminen, L. Pandola, S. Parlati, L. Peralta, J. Perl, A. Pfeiffer, M. Pia, A. Ribon, P. Rodrigues, G. Russo, S. Sadilov, G. Santin, T. Sasaki, D. Smith, N. Starkov, S. Tanaka, E. Tcherniaev, B. Tome, A. Trindade, P. Truscott, L. Urban, M. Verderi, A. Walkden, J. Wellisch, D. Williams, D. Wright, and H. Yoshida, Geant4 developments and applications, IEEE Transactions on Nuclear Science 53, 270 (2006).
  30. [34]J. Allison, K. Amako, J. Apostolakis, P. Arce, M. Asai, T. Aso, E. Bagli, A. Bagulya, S. Banerjee, G. Barrand, B. R. Beck, A. G. Bogdanov, D. Brandt, J. M. C. Brown, H. Burkhardt, P. Canal, D. Cano-Ott, S. Chauvie, K. Cho, G. A. P. Cirrone, G. Cooperman, M. A. Cortés-Giraldo, G. Cosmo, G. Cuttone, G. Depaola, L. Desorgher, X. Dong, A. Dotti, V. D. Elvira, G. Folger, Z. Francis, A. Galoyan, L. Garnier, M. Gayer, K. L. Genser, V. M. Grichine, S. Guatelli, P. Guèye, P. Gumplinger, A. S. Howard, I. Hrivnàčová, S. Hwang, S. Incerti, A. Ivanchenko, V. N. Ivanchenko, F. W. Jones, S. Y. Jun, P. Kaitaniemi, N. Karakatsanis, M. Karamitros, M. Kelsey, A. Kimura, T. Koi, H. Kurashige, A. Lechner, S. B. Lee, F. Longo, M. Maire, D. Mancusi, A. Mantero, E. Mendoza, B. Morgan, K. Murakami, T. Nikitina, L. Pandola, P. Paprocki, J. Perl, I. Petrovic, M. G. Pia, W. Pokorski, J. M. Quesada, M. R aine, M. A. Reis, A. Ribon, A. Ristić Fira, F. Romano, G. Russo, G. Santin, T. Sasaki, D. Sawkey, J. I. Shin, I. I. Strakovsky, A. Taborda, S. Tanaka, B. Tomé, T. Toshito, H. N. Tran, P. R. Truscott, L. Urban, V. Uzhinsky, J. M. Verbeke, M. Verderi, B. L. Wendt, H. Wenzel, D. H. Wright, D. M. Wright, T. Yamashita, J. Yarba, and H. Yoshida, Recent developments in Geant4, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 835, 186 (2016).
  31. [35]K. Nakamura, H.-S. Mao, A. J. Gonsalves, H. Vincenti, D. E. Mittelberger, J. Daniels, A. Magana, C. Toth, and W. P. Leemans, Diagnostics, Control, and Performance Parameters for the BELLA High Repetition Rate Petawatt Class Laser, IEEE Journal of Quantum Electronics 53, 1 (2017), conference Name: IEEE Journal of Quantum Electronics.DOI
  32. [36]B. Miao, J. E. Shrock, E. Rockafellow, A. J. Sloss, and H. M. Milchberg, Meter-scale supersonic gas jets for multi-GeV laser-plasma accelerators, Review of Scientific Instruments 96, 043003 (2025).
  33. [37]C. G. Durfee and H. M. Milchberg, Light pipe for high intensity laser pulses, Physical Review Letters 71, 2409 (1993), publisher: American Physical Society.
  34. [38]R. J. Shalloo, C. Arran, L. Corner, J. Holloway, J. Jonnerby, R. Walczak, H. M. Milchberg, and S. M. Hooker, Hydrodynamic optical-field-ionized plasma channels, Physical Review E 97, 053203 (2018), publisher: American Physical Society; R. Shalloo, C. Arran, A. Picksley, A. von Boetticher, L. Corner, J. Holloway, G. Hine, J. Jonnerby, H. Milchberg, C. Thornton, R. Walczak, and S. Hooker, Low-density hydrodynamic optical-field-ionized plasma channels generated with an axicon lens, Physical Review Accelerators and Beams 22, 041302 (2019), publisher: American Physical Society; A. Picksley, A. Alejo, R. J. Shalloo, C. Arran, A. von Boetticher, L. Corner, J. A. Holloway, J. Jonnerby, O. Jakobsson, C. Thornton, R. Walczak, and S. M. Hooker, Meter-scale conditioned hydrodynamic optical-field-ionized plasma channels, Physical Review E 102, 053201 (2020), publisher: American Physical Society; A. Picksley, A. Alejo, J. Cowley, N. Bourgeois, L. Corner, L. Feder, J. Holloway, H. Jones, J. Jonnerby, H. Milchberg, L. Reid, A. Ross, R. Walczak, and S. Hooker, Guiding of high-intensity laser pulses in 100-mm-long hydrodynamic optical-field-ionized plasma channels, Physical Review Accelerators and Beams 23, 081303 (2020), publisher: American Physical Society; A. Picksley, A. Alejo, J. Cowley, N. Bourgeois, L. Corner, L. Feder, J. Holloway, H. Jones, J. Jonnerby, H. Milchberg, L. Reid, A. Ross, R. Walczak, and S. Hooker, All-Optical GeV Electron Bunch Generation in a Laser-Plasma Accelerator via Truncated-Channel Injection, Physical Review Letters 131, 245001 (2023), publisher: American Physical Society.DOI
  35. [39]N. Lemos, L. Cardoso, J. Geada, G. Figueira, F. Albert, and J. M. Dias, Guiding of laser pulses in plasma waveguides created by linearly-polarized femtosecond laser pulses, Scientific Reports 8, 3165 (2018), publisher: Nature Publishing Group.DOI
  36. [40]L. Feder, B. Miao, J. E. Shrock, A. Goffin, and H. M. Milchberg, Self-waveguiding of relativistic laser pulses in neutral gas channels, Physical Review Research 2, 043173 (2020), publisher: American Physical Society; B. Miao, L. Feder, J. Shrock, A. Goffin, and H. Milchberg, Optical Guiding in Meter-Scale Plasma Waveguides, Physical Review Letters 125, 074801 (2020), publisher: American Physical Society.DOI
  37. [41]D. E. Groom, N. V. Mokhov, and S. I. Striganov, Muon stopping power and range tables 10 MeV–100 TeV, Atomic Data and Nuclear Data Tables 78, 183 (2001).
  38. [42]R. Frühwirth and M. Regler, On the quantitative modelling of core and tails of multiple scattering by Gaussian mixtures, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 456, 369 (2001).DOI
  39. [43]H. A. Bethe, Moliere’s Theory of Multiple Scattering, Physical Review 89, 1256 (1953), publisher: American Physical Society.DOI
  40. [44]L. Dahing, R. Yahya, R. Yahya, and H. Hassan, Non destructive multi elemental analysis using prompt gamma neutron activation analysis techniques: Preliminary results for concrete sample, AIP Conference Proceedings 1614, 20 (2014).DOI
  41. [45]C. Benedetti, C. B. Schroeder, E. Esarey, C. G. R. Geddes, and W. P. Leemans, Efficient Modeling of Laser-Plasma Accelerators with INF&RNO, AIP Conference Proceedings 1299, 250 (2010).
  42. [46]C. Benedetti, C. B. Schroeder, C. G. R. Geddes, E. Esarey, and W. P. Leemans, An accurate and efficient laser-envelope solver for the modeling of laser-plasma accelerators, Plasma Physics and Controlled Fusion 60, 014002 (2017), publisher: IOP Publishing.DOI

Paper details

vlnc:W_axtqmdqa
Version
v1 · latest