betaFeedback

WorksPhysics and Astronomy

Asynchronous Terahertz-field sampling with soliton microcombs

Abstract

Terahertz time-domain spectroscopy records the electric field of terahertz transients and underpins applications from materials science to non-destructive testing. Asynchronous optical sampling enables systems without moving parts, but its acquisition rate remains fundamentally limited by the repetition-rate of the driving femtosecond lasers. Here, we demonstrate asynchronous terahertz-field sampling with two chip-based soliton microcombs. Their ultrahigh 25 GHz pulse repetition-rate drastically reduces dead-time during acquisition, and stabilization via sideband injection-locking enables coherent averaging without active feedback loops. At 10 kHz acquisition rate, we achieve a dynamic range of 74 dB in a single 100 μμs scan, and 100 dB after 50 ms of coherent averaging with a 1.6 THz bandwidth. Acquisition rates of up to 100 kHz are demonstrated, limited only by detection electronics. Together with a proof-of-concept silicon wafer thickness measurement, these results establish soliton microcombs as compact sources for rapid terahertz-field sampling.

Introduction

Terahertz time-domain spectroscopy (THz-TDS)[1] is a key spectroscopic technique in the 0.1–10 THz band. It underpins fundamental research in physics and materials as well as applications[2, 3, 4, 5], ranging from non-destructive inspection of coatings[6, 7, 8] and security screening[9, 10, 11] to pharmaceuticals[12, 13, 14] and biomedical sensing[15, 16, 17, 18]. In THz-TDS, a first femtosecond pulse generates a THz transient usually in a photoconductive antenna (PCA) or by optical rectification. A second femtosecond pulse with a variable delay samples the THz field after interaction with the sample, by gating a second PCA or via electro-optic detection.

To accurately sample the THz field, the delay between generating and sampling pulse must be scanned with precisely known timing and low jitter. A single pulse source may be utilized, combined with pulse splitting and a mechanical delay stage. However, mechanical delay stages limit scan rates to the Hz range and introduce vibration and scan nonlinearity. In contrast, asynchronous optical sampling (ASOPS)[19] uses two femtosecond sources with repetition-rates frepf_{\mathrm{rep}} and frep+Δfrepf_{\mathrm{rep}}+\Delta f_{\mathrm{rep}} (Δfrep≪frep\Delta f_{\mathrm{rep}} \ll f_{\mathrm{rep}}), sweeping the full delay window 1/frep1/f_{\mathrm{rep}} at the rate Δfrep\Delta f_{\mathrm{rep}} without moving parts (Figure 1a). Effectively, ASOPS stretches the THz waveform in time by frep/Δfrepf_{\mathrm{rep}}/\Delta f_{\mathrm{rep}}, so that it can be electronically recorded. However, the THz response of condensed-matter systems typically lasts only tens of picoseconds. For well-established sources with frep∼100f_{\mathrm{rep}} \sim100 MHz, the resulting 10 ns scan window far exceeds this response duration, so most of each scan consists of dead-time carrying no useful signal. Repetition-rate modulation schemes such as OSCAT[20] and ECOPS[21] confine the sweep to the window of interest and have reached 8 kHz scan rates over 180 ps at the cost of experimental complexity[22].

Figure 1. Concept of THz-TDS with soliton microcombs. a, Asynchronous optical sampling technique using two optical pulse trains for THz generation (emitter) and THz sampling (receiver) with scan range of 1/Δfrep1/\Delta f_{\mathrm{rep}}. The sampled THz signal is stretched in time by a factor frep/Δfrepf_{\mathrm{rep}}/\Delta f_{\mathrm{rep}}. Inset: Spectrum of the THz waveform obtained via Fast Fourier transform (FFT) of the time domain signal. FFT of a train of sampled THz signals results in a comb-like spectrum. b, Conceptual setup for asynchronous THz field sampling with microcombs. Two chip-integrated Si3_3N4_4 photonic crystal microresonators (PhCR) serve as ultra-short pulse sources with repetition rate difference Δfrep\Delta f_{\mathrm{rep}}. Pulses from a first microcomb are sent to an emitter, generating a THz transient which, after collimation, travels through a sample. Pulses from a second microcomb are sent to a photoconductive receiver where they gate the THz transient to generate a momentary field-dependent nA-level current. A transimpedance amplifier (TIA) converts the current to a voltage signal, which is sampled by an oscilloscope. (See a). c, Illustration of the microcomb spectra, with a shared continuous-wave pump line at the central mode with relative mode number μ=0\mu= 0. Sideband-injection with two continuous-wave lasers at relative mode μ′\mu' enables all-optical control over their repetition rates frepf_{\mathrm{rep}} and frep+Δfrepf_{\mathrm{rep}} + \Delta f_{\mathrm{rep}}.

An elegant way to reduce dead-time is by using higher repetition-rate pulse sources. For condensed-matter samples with a short THz response, frepf_{\mathrm{rep}} of tens of GHz is possible without temporal overlap of consecutive responses. Moreover, a higher repetition-rate also permits a faster scan rate (Δfrep\Delta f_{\mathrm{rep}}), while maintaining the temporal stretching of the THz signal needed for a given electronics bandwidth. Following this route, 1 GHz single-cavity dual-comb lasers have enabled 22 kHz scan rates[23], and two 10 GHz Ti:sapphire oscillators reached 100 kHz[24]. Mode-locked lasers at such repetition-rates are, however, demanding to build, operate and stabilize.

Complementing mode-locked lasers, soliton microcombs[25, 26, 27] readily provide access to femtosecond pulses at high-repetition-rates, spanning from 10 GHz to 1 THz. They are usually generated via the formation of dissipative soliton pulses in continuous-wave driven Kerr-nonlinear microresonators[28, 29]. Recent advances have led to electrically-driven chip-scale microcombs with drastically reduced operational complexity[30, 31, 32, 33, 34]. Microcombs have enabled new applications, including wavelength-multiplexed optical communication[35], astronomy[36, 37], and rapid dual comb spectroscopy[38]. Microresonator based systems have also been utilized to generate THz signals[39, 40, 41, 42], including for THz-TDS with a mechanically scanned delay[43].

Here, we demonstrate asynchronous THz-field sampling with two amplified femtosecond soliton microcombs with 25 GHz repetition-rate (Figure 1b), reaching a THz bandwidth of up to 1.6 THz. The 40 ps pulse period exceeds the duration of condensed-matter THz transients and largely eliminates the dead-time of lower-repetition-rate systems. The high pulse repetition-rate also enables a high acquisition rate Δfrep\Delta f_{\mathrm{rep}}, which we set at 10, 25 and 100 kHz; while the microcombs would support MHz scan rates, the rate here is limited by the sampling electronics. Repetition-rates are stabilized by Kerr-sideband injection locking (Kerr nonlinear synchronization)[44, 45, 46, 47, 48], which provides the ultra-low relative timing jitter required for coherent averaging (Figure 1c). At a 10 kHz scan rate we obtain a dynamic range of 74 dB in a single scan and 100 dB after coherent averaging over 50 ms. As an example, we demonstrate phase-resolved transmission spectroscopy of a silicon wafer. These results position soliton microcombs as compact, high-repetition-rate sources for rapid THz-field sampling and spectroscopy.

Results

The setup (Figure 2a) consists of two blocks: a dual-microcomb source providing two amplified 25 GHz femtosecond pulse trains with slightly detuned repetition-rates, and the THz-TDS part comprising the THz-generating and sampling PCAs. The microcombs are based on two Si3_3N4_4 racetrack photonic crystal microresonators (PhCR) with free spectral ranges close to 25 GHz, both pumped by a common CW laser of frequency fpf_{\mathrm{p}} (1560 nm wavelength) delivering an on-chip power of 60 mW in each resonator. A corrugation along part of the resonator waveguide shapes the dispersion such that single dissipative Kerr soliton (DKS) states form deterministically. In this configuration, the DKS pulses form in the blue-detuned regime and counter-propagate with respect to the pump (see Methods)[49]; they are out-coupled via circulators. Free-running, the repetition-rates of the two microcombs differ by approximately 300 kHz.

Experimental setup and optical pulses characterization

Figure 2. Experimental setup and optical pulses characterization. a, Experimental setup in two parts: microcomb generation and repetition rate control, as well as, THz generation and sampling. CW, continuous wave lasers for pump and injection; AOM, acousto-optic modulator; EDFA, erbium-doped fibre amplifier; CIRC, circulator; FBG, fibre Bragg grating; TIA, transimpedance amplifier; OSC, oscilloscope. EDFAs and waveshaper are used for pulse amplification and compensation of dispersion. Arrows indicate the direction of light propagation. b, Optical spectra of free-running combs before (dark blue and dark lilac) and after the amplification and dispersion compensation (light blue and light lilac), where we also filter out the pump and injection modes (dips at 1561 nm and 1582 nm respectively). c, Second-harmonic intensity autocorrelation measurements after amplification and dispersion compensation yield pulse durations of ∼300\sim300 fs, assuming sech2^{2}-pulses.

To enable longer acquisition and signal averaging, we stabilize the microcombs’ repetition rate via sideband injection locking[46, 47, 48]: a second CW laser of frequency finjf_{\mathrm{inj}} (1582 nm wavelength, on-chip power ∼5\sim5 mW) is injected into each resonator (co-propagating with the solitons), at comb mode μ=100\mu= 100 relative to the pump. Via the Kerr nonlinearity, the comb line at mode μ\mu locks to the injected frequency, which fixes the repetition-rate to frep=∣finj−fp∣/μf_{\mathrm{rep}} = \lvert f_{\mathrm{inj}} - f_{\mathrm{p}}\rvert/\mu. Prior to injection, the laser is split into two paths where it is differentially frequency-shifted by acousto-optic modulators (AOMs) driven at fm,i≈80f_{\mathrm{m},i} \approx80 MHz (microcomb index i=1,2i = 1, 2), so that the two microcombs lock to frep,i=∣finj+fm,i−fp∣/μf_{\mathrm{rep},i} = \lvert f_{\mathrm{inj}} + f_{\mathrm{m},i} - f_{\mathrm{p}}\rvert/\mu. Their difference, Δfrep=∣fm,2−fm,1∣/μ\Delta f_{\mathrm{rep}} = \lvert f_{\mathrm{m},2} - f_{\mathrm{m},1}\rvert/\mu, is therefore set purely electronically via the AOM modulation frequencies. The values of Δfrep\Delta f_{\mathrm{rep}} of 10 to 100 kHz used here correspond to AOM frequency difference of 1 to 10 MHz. Both AOM drivers share a common clock.

At each microcomb output, a fibre Bragg grating removes the residual pump light, an erbium-doped fibre amplifier (EDFA) amplifies the pulses to up to 200 mW of average power (8 pJ pulse energy). A programmable spectral filter (waveshaper) compensates the dispersion accumulated in the fibre path and removes the injection laser line. The optical spectra of the two free-running microcombs and the amplified spectra are shown in Figure 2b. Second-harmonic intensity autocorrelation measurements of the amplified pulses indicate near transform limited pulse durations of approximately 300 fs (FWHM, assuming a sech2^{2} pulse shape), corresponding to a peak power of approximately 24 W (Figure 2c).

The THz-TDS part of the setup consists of two fibre-coupled, photoconductive modules (see Methods) with hyperhemispherical silicon lenses. One of the two 25 GHz pulse trains (average power 20 mW) is sent to the emitter PIN photodiode, which is biased at −1.2-1.2 V. At the PIN photodiode each optical pulse generates a THz transient, resulting in a train of THz pulses with 25 GHz repetition-rate. The THz beam is collimated by a parabolic mirror, propagates in air, and is focused by a second parabolic mirror onto the unbiased receiver PCA. There, the second pulse train (average power 200 mW) gates the receiver, such that a photocurrent proportional to the momentary THz field is generated. The current is converted into a voltage by a transimpedance amplifier (TIA) and recorded by an oscilloscope. As the two microcomb repetition-rates differ by Δfrep\Delta f_{\mathrm{rep}}, the sampling gate slides temporally through the THz transient, sweeping across the full delay window of 1/frep=401/f_{\mathrm{rep}} = 40 ps once every 1/Δfrep1/\Delta f_{\mathrm{rep}} (100 μ\mus at Δfrep=10\Delta f_{\mathrm{rep}} = 10 kHz). The recorded signal corresponds to the THz waveform stretched in time by frep/Δfrepf_{\mathrm{rep}}/\Delta f_{\mathrm{rep}} (2.5×1062.5 \times10^{6} at 10 kHz), and is recorded by an oscilloscope (as shown in Figure 1a). A trigger signal at Δfrep\Delta f_{\mathrm{rep}}, derived from the same clock as the AOM drivers, provides the timing reference for the recorded traces and allows consecutive scans to be aligned and averaged.

An example of the recorded THz signal is shown in Figure 3a for Δfrep=10\Delta f_{\mathrm{rep}} = 10 kHz; the TIA bandwidth and gain are set to 1.8 MHz and 10610^{6} V/A. The sampled THz transient repeats at 1/Δfrep=1001/\Delta f_{\mathrm{rep}} = 100 μ\mus. Owing to the 25 GHz repetition-rate, the dead-time between consecutive transients is short, in contrast to a typical sub-percent duty cycle of conventional ASOPS systems with ∼100\sim100 MHz repetition-rate. Figure 3b shows individual delay scans, each of duration 1/Δfrep1/\Delta f_{\mathrm{rep}}, for Δfrep=10\Delta f_{\mathrm{rep}} = 10, 25 and 100 kHz; the transient is clearly resolved in all cases. Owing to the stabilized repetition rate, consecutive scans can directly be coherently averaged over NN scans to improve the signal-to-noise ratio.

Figure 3. a, Recorded THz sampling signal with Δfrep=10\Delta f_{\mathrm{rep}} = 10 kHz. b, THz transients sampled over the duration of a single delay scan 1/Δfrep1/\Delta f_{\mathrm{rep}} for different values of frep=10f_{\mathrm{rep}} = 10, 25, 100 kHz. c, Power spectra (normalized to the peak) obtained from a single delay scan and with averaging NN delay scans with an effective acquisition time of N/ΔfrepN/\Delta f_{\mathrm{rep}} for frep=10f_{\mathrm{rep}} = 10, 25, 100 kHz. d, Power spectrum of the full acquired trace for Δfrep=10\Delta f_{\mathrm{rep}} = 10 kHz for 50 ms averaging. The frequency components’ spacing of the THz comb correspond to the microcomb repetition-rate frep=25.13f_{\mathrm{rep}} = 25.13 GHz.

To assess the THz bandwidth, we Fast-Fourier transform (FFT) the recorded delay scans, considering both single scan (N=1N = 1) and coherent averages over NN scans, corresponding to scan times of N/ΔfrepN/\Delta f_{\mathrm{rep}} (Figure 3c). The spectra are sampled at the 25 GHz line spacing of the microcombs’ repetition-rate, which sets the spectral resolution. It is visible in Figure 3d, where the FFT is performed over the full scan of 50 ms. For Δfrep=10\Delta f_{\mathrm{rep}} = 10 kHz, the spectrum extends to ∼1.6\sim1.6 THz before reaching the noise floor approximately 80 dB below the maximum. At higher scan rates, the bandwidth is reduced: since the THz waveform is stretched in time by frep/Δfrepf_{\mathrm{rep}}/\Delta f_{\mathrm{rep}}, the TIA bandwidth BTIA=1.8B_{\mathrm{TIA}} = 1.8 MHz limits the detectable THz frequencies to BTIA×frep/ΔfrepB_{\mathrm{TIA}} \times f_{\mathrm{rep}}/\Delta f_{\mathrm{rep}}, i.e., 4.5, 1.8 and 0.45 THz for Δfrep=10\Delta f_{\mathrm{rep}} = 10, 25 and 100 kHz, respectively. The bandwidth observed at 10 kHz is thus not limited by the TIA but by the antennas and the optical pulse duration. Higher scan rates, up to the MHz range supported by the microcombs, would require a TIA of correspondingly higher bandwidth at the expense of transimpedance gain. Signal averaging over multiple scans lowers the noise floor, but the improvement saturates for large NN, as contributions to the background that are synchronous with the THz waveform, such as electronic pickup at harmonics of Δfrep\Delta f_{\mathrm{rep}}, average coherently and, therefore, are not reduced. Unlike incoherent noise, however, this coherent background can be measured with the THz beam blocked and subtracted, as shown below.

Next, we perform a transmission measurement on a 600 μ\mum thick high-resistivity float-zone silicon (HRFZ-Si) wafer, whose refractive index n=3.4175n = 3.4175 is essentially constant and whose absorption and group velocity dispersion are negligible within the obtained THz signal[52]. The wafer is placed in the collimated THz beam, slightly tilted at an angle of approximately 20∘20^\circ to avoid back-reflections (for simplicity we ignore this tilt in the considerations presented below). The TIA is set to 10510^5 V/A gain and 3.5 MHz bandwidth. At Δfrep=10\Delta f_{\mathrm{rep}} = 10 kHz, we record the signal with the wafer in the beam path (sample), without it (reference), and with the beam blocked (background). Single scan signals are shown in Figure 4a; the dominant effect of the wafer is a delay of the transient by approximately 5 ps, corresponding to the additional propagation delay (n−1)d/c(n - 1)d/c, together with a reduced amplitude due to Fresnel reflection losses. In addition, a weaker replica of the transient, delayed by the wafer-internal round-trip time 2nd/c≈142nd/c \approx14 ps, results from the Fabry–Pérot reflections within the wafer.

Figure 4. THz spectroscopy of a silicon wafer. a, Single delay scan time-domain traces with Δfrep=10\Delta f_{\mathrm{rep}} = 10 kHz for a Si wafer sample (orange), reference (blue, no wafer), and background (lilac, THz beam blocked) signal. b, Power spectra of the time domain signals without the wafer (top panel) and with wafer sample (bottom panel) measurement (normalized to the noise level, extracted as the root-mean-square of the background measurement, lilac). Power spectra are shown for a single delay scans (light blue and yellow) as well for N=500N = 500 averages over 50 ms of acquisition time (blue and orange). c, Dynamic range for 0.1, 0.25, 0.5 and 1 THz frequencies as a function of the averaging time, showing a linear scaling[50]. d, Unwrapped phase information obtained from a single delay scan for reference (without wafer) and sample (with wafer) signal after background subtraction; we also indicate their linear phase difference encoding the group delay of THz signal by the wafer[51]. e, Same as panel d, but for the averaged data (N=500N = 500). f, Additional group delay, imposed by the sample as derived from the differential phase slope between reference and sample measurements (see main text).

We process sample, reference, and background traces as described above, for single delay scans and for coherently averaged scans, and subtract the background signal in the time domain prior to the FFT operation to remove the coherent background. The resulting reference and sample spectra, normalized to the noise-level extracted as the root-mean-square of the background measurement, are shown in Figure 4b, along with the background spectrum in the top and bottom panels, respectively. The maximal dynamic range (peak-to-noise-floor ratio) for reference (sample) reaches 74 dB (72 dB) in a single scan of 100 μ\mus in duration, and 100 dB (98 dB) after ∼50\sim50 ms of coherent averaging of N=500N = 500 scans. To characterize how the dynamic range scales with measurement time, we evaluate it at several THz frequencies (0.1, 0.25, 0.5 and 1 THz) as a function of the averaging time N/ΔfrepN/\Delta f_{\mathrm{rep}} (Figure 4c). At all frequencies the dynamic range increases by 10 dB per decade of averaging time, i.e., from 60 dB in a single 100 μ\mus scan to 87 dB after 50 ms at 0.25 THz, as expected for coherent averaging[50], where the signal power grows as N2N^2 while the noise power grows only as NN. Apart from the Fresnel reflection losses and the etalon fringes, the sample and reference spectra show no significant difference in spectral amplitude, consistent with the negligible absorption of HRFZ-Si. However, the spectral phase is modified by the wafer: the difference Δφ(ω)\Delta\varphi(\omega) between the unwrapped sample and reference phases (Figure 4d, Figure 4e) is linear in (angular) frequency ω\omega, corresponding to an additional spectrally flat group delay τ=Δφ(ω)/ω=const\tau= \Delta\varphi(\omega)/\omega= \mathrm{const} imposed by the wafer on the THz wave. From the single scan and coherently averaged measurements we derive for each frequency the group delay as shown in Figure 4f, obtaining mean (additional) group delays of 5.15 ps and 5.16 ps for the two measurements over the bandwidth from 0.2 to 1 THz and 1.6 THz, respectively. Assuming n=3.4175n = 3.4175, we estimate the thickness of the sample from the measured additional group delay as d≈τc/(n−1)=639.3d \approx\tau c/(n - 1) = 639.3 μ\mum and 639.5 μ\mum, respectively. The good agreement between both values demonstrates that a single delay scan suffices for rapid and precise thickness measurements.

Discussion

In conclusion, we have demonstrated asynchronous THz-field sampling with two chip-integrated 25 GHz soliton microcombs. The setup does neither require mechanically moving parts, nor active feedback loops. In contrast to conventional ASOPS, the high repetition rate reduces the dead time when measuring fast condensed-matter THz transients, and enables rapid acquisition of THz waveforms and spectra. The acquisition rates of up to 100 kHz demonstrated here are limited by the transimpedance amplifier and not by the microcomb source, which would support MHz rates. Kerr-nonlinear synchronization of the two microcombs via sideband injection locking provides the timing stability required for coherent averaging. The trade-off of THz-TDS with high 25 GHz repetition-rate is the reduced spectral resolution given by the repetition-rate, which suits solids, thin films, and liquids with broad spectral features but not gas-phase spectroscopy of narrow rotational lines.

While pulse amplification and dispersion compensation remain off-chip in the present demonstration, recent progress in integrated pulse amplifiers[53, 54], on-chip dispersion compensation[55, 56], waveguide integrated photoconductive elements[57], and electro-optic generation and detection in thin-film lithium niobate[58] point towards fully integrated systems for rapid THz-field sampling[59].

Methods

Microresonators characterization. Two photonic crystal microresonators (PhCR) are commercially manufactured on a Si3_3N4_4 photonic chip platform by ultraviolet stepper optical lithography by LIGENTEC SA. The microresonators share an identical racetrack geometry, yielding a free spectral range (FSR) of 25.132 GHz. Their waveguide cross-section of 2×0.82 \times0.8 μ\mum on an 800-nm-thick platform provides anomalous group-velocity dispersion (D2/2π=59D_2/2\pi= 59 kHz) with a local region of D2′/2π=20D_2'/2\pi= 20 MHz near the pump due to engineered mode hybridization[49]. Each microresonator is critically coupled with loaded quality factor of Q≈5×106Q \approx5 \times10^6 corresponding to a total resonance linewidth of κ/2π≈40\kappa/2\pi\approx40 MHz.

THz antennas. Two fiber-coupled optoelectronic THz antennas are used, one as an emitter and one as a receiver. The emitter is a waveguide-integrated PIN photodiode with an attached planar antenna based on an indium phosphide platform[60]. It is reversibly biased with −1.2-1.2 V. The receiver is a rhodium-doped GaAs photoconductive antenna (PCA)[61]. Both emitter and receiver are mounted on hyper-hemispherical silicon lenses and integrated into fiber-pigtailed modules.

Funding. This project has received funding from the European Research Council (ERC grant agreement No 853564), the European Innovation Council (EIC grant agreement No 101137000), and the Helmholtz Young Investigators Group VH-NG-1404; the work was supported through the Maxwell computational resources operated at DESY.

References

  1. [1]Koch, M., Mittleman, D. M., Ornik, J. & Castro-Camus, E. Terahertz time-domain spectroscopy. Nature Reviews Methods Primers 3, 48 (2023).
  2. [2]Tonouchi, M. Cutting-Edge Terahertz Technology. Nature Photonics 1, 97–105 (2007).DOI
  3. [3]Jepsen, P., Cooke, D. & Koch, M. Terahertz Spectroscopy and Imaging – Modern Techniques and Applications. Laser & Photonics Reviews 5, 124–166 (2011).DOI
  4. [4]Naftaly, M., Vieweg, N. & Deninger, A. Industrial Applications of Terahertz Sensing: State of Play. Sensors (Basel, Switzerland) 19 (2019).DOI
  5. [5]Leitenstorfer, A., Moskalenko, A. S., Kampfrath, T., Kono, J., Castro-Camus, E., Peng, K., Qureshi, N., Turchinovich, D., Tanaka, K., Markelz, A. G., Havenith, M., Hough, C., Joyce, H. J., Padilla, W. J., Zhou, B., Kim, K.-Y., Zhang, X.-C., Jepsen, P. U., Dhillon, S., Vitiello, M., Linfield, E., Davies, A. G., Hoffmann, M. C., Lewis, R., Tonouchi, M., Klarskov, P., Seifert, T. S., Gerasimenko, Y. A., Mihailovic, D., Huber, R., Boland, J. L., Mitrofanov, O., Dean, P., Ellison, B. N., Huggard, P. G., Rea, S. P., Walker, C., Leisawitz, D. T., Gao, J. R., Li, C., Chen, Q., Valušis, G., Wallace, V. P., Pickwell-MacPherson, E., Shang, X., Hesler, J., Ridler, N., Renaud, C. C., Kallfass, I., Nagatsuma, T., Zeitler, J. A., Arnone, D., Johnston, M. B. & Cunningham, J. The 2023 Terahertz Science and Technology Roadmap. Journal of Physics D: Applied Physics 56, 223001 (2023).
  6. [6]Fitzgerald, A. J., Cole, B. E. & Taday, P. F. Nondestructive analysis of tablet coating thicknesses using terahertz pulsed imaging. Journal of pharmaceutical sciences 94, 177–183 (2005).pubmed.ncbi.nlm.nih.gov/15761941
  7. [7]Zeitler, J. A., Shen, Y., Baker, C., Taday, P. F., Pepper, M. & Rades, T. Analysis of coating structures and interfaces in solid oral dosage forms by three dimensional terahertz pulsed imaging. Journal of pharmaceutical sciences 96, 330–340 (2007).pubmed.ncbi.nlm.nih.gov/17075850
  8. [8]Tao, Y. H., Fitzgerald, A. J. & Wallace, V. P. Non-contact, non-destructive testing in various industrial sectors with terahertz technology. Sensors 20, 712 (2020).DOI
  9. [9]Federici, J. F., Schulkin, B., Huang, F., Gary, D., Barat, R., Oliviera, F. & Zimdars, D. THz imaging and sensing for security applications – explosives, weapons and drugs. Semiconductor Science and Technology 20, S266–S280 (2005).DOI
  10. [10]Tzydynzhapov, G., Gusikhin, P., Muravev, V., Dremin, A., Nefyodov, Y. & Kukushkin, I. New real-time sub-terahertz security body scanner. Journal of Infrared, Millimeter, and Terahertz Waves 41, 632–641 (2020).DOI
  11. [11]Jiang, X., Li, Y., Li, Y., Shen, C.-Y., Ozcan, A. & Jarahi, M. Detection and imaging of chemicals and hidden explosives using terahertz time-domain spectroscopy and deep learning. Light: Science & Applications 15, 80 (2026).DOI
  12. [12]Zeitler, J. A., Taday, P. F., Newnham, D. A., Pepper, M., Gordon, K. C. & Rades, T. Terahertz pulsed spectroscopy and imaging in the pharmaceutical setting – a review. Journal of Pharmacy and Pharmacology 59, 209–223 (2007).pubmed.ncbi.nlm.nih.gov/17270075
  13. [13]Bawuah, P. & Zeitler, J. A. Advances in terahertz time-domain spectroscopy of pharmaceutical solids: A review. TrAC Trends in Analytical Chemistry 139, 116272 (2021).DOI
  14. [14]Moradikouchi, A., Sparén, A., Svensson, O., Folestad, S., Stake, J. & Rodilla, H. Terahertz frequency-domain sensing combined with quantitative multivariate analysis for pharmaceutical tablet inspection. International Journal of Pharmaceutics 632, 122545 (2023).DOI
  15. [15]Knobloch, P., Schildknecht, C., Kleine-Ostmann, T., Koch, M., Hoffmann, S., Hoffmann, M., Rehberg, E., Sperling, M., Donhuijsen, K., Hein, G., et al. Medical THz imaging: an investigation of histo-pathological samples. Physics in Medicine & Biology 47, 3875–3884 (2002).pubmed.ncbi.nlm.nih.gov/12452579
  16. [16]Yu, C., Fan, S., Sun, Y. & Pickwell-MacPherson, E. The potential of terahertz imaging for cancer diagnosis: A review of investigations to date. Quantitative Imaging in Medicine and Surgery 2, 33–45 (2012).DOI
  17. [17]Cong, M., Li, W., Liu, Y., Bi, J., Wang, X., Yang, X., Zhang, Z., Zhang, X., Zhao, Y.-N., Zhao, R., et al. Biomedical application of terahertz imaging technology: a narrative review. Quantitative imaging in medicine and surgery 13, 8768 (2023).DOI
  18. [18]Yang, X., Zhao, X., Yang, K., Liu, Y., Liu, Y., Fu, W. & Luo, Y. Biomedical applications of terahertz spectroscopy and imaging. Trends in biotechnology 34, 810–824 (2016).DOI
  19. [19]Janke, C., Först, M., Nagel, M., Kurz, H. & Bartels, A. Asynchronous optical sampling for high-speed characterization of integrated resonant terahertz sensors. Optics letters 30, 1405–1407 (2005).pubmed.ncbi.nlm.nih.gov/15981548
  20. [20]Hochrein, T., Wilk, R., Mei, M., Holzwarth, R., Krumbholz, N. & Koch, M. Optical sampling by laser cavity tuning. Optics Express 18, 1613–1617 (2010).DOI
  21. [21]Kim, Y. & Yee, D.-S. High-speed terahertz time-domain spectroscopy based on electronically controlled optical sampling. Optics letters 35, 3715–3717 (2010).DOI
  22. [22]Dietz, R. J., Vieweg, N., Puppe, T., Zach, A., Globisch, B., Göbel, T., Leisching, P. & Schell, M. All fiber-coupled THz-TDS system with kHz measurement rate based on electronically controlled optical sampling. Optics letters 39, 6482–6485 (2014).DOI
  23. [23]Willenberg, B., Phillips, C. R., Pupeikis, J., Camenzind, S. L., Liebermeister, L., Kohlhass, R. B., Globisch, B. & Keller, U. THz-TDS with gigahertz Yb-based dual-comb lasers: noise analysis and mitigation strategies. Applied optics 63, 4144–4156 (2024).DOI
  24. [24]Kliebisch, O., Heinecke, D. C. & Dekorsy, T. Ultrafast time-domain spectroscopy system using 10 GHz asynchronous optical sampling with 100 kHz scan rate. Optics Express 24, 29930–29940 (2016).DOI
  25. [25]Kippenberg, T. J., Gaeta, A. L., Lipson, M. & Gorodetsky, M. L. Dissipative Kerr Solitons in Optical Microresonators. Science 361 (2018).
  26. [26]Pasquazi, A., Peccianti, M., Razzari, L., Moss, D. J., Coen, S., Erkintalo, M., Chembo, Y. K., Hansson, T., Wabnitz, S., Del’Haye, P., Xue, X., Weiner, A. M. & Morandotti, R. Micro-Combs: A Novel Generation of Optical Sources. Physics Reports 729, 1–81 (2018).DOI
  27. [27]Herr, T., Tikan, A. & Kippenberg, T. J. Frequency Combs and Coherent Dissipative Structures in Nonlinear Optical Microresonators. arXiv:2604.05897 (2026).arxiv.org/abs/2604.05897
  28. [28]Leo, F., Coen, S., Kockaert, P., Gorza, S.-P., Emplit, P. & Haelterman, M. Temporal Cavity Solitons in One-Dimensional Kerr Media as Bits in an All-Optical Buffer. Nature Photonics 4, 471–476 (2010).DOI
  29. [29]Herr, T., Brasch, V., Jost, J. D., Wang, C. Y., Kondratiev, N. M., Gorodetsky, M. L. & Kippenberg, T. J. Temporal Solitons in Optical Microresonators. Nature Photonics 8, 145–152 (2014).DOI
  30. [30]Stern, B., Ji, X., Okawachi, Y., Gaeta, A. L. & Lipson, M. Battery-Operated Integrated Frequency Comb Generator. Nature 562, 401–405 (2018).DOI
  31. [31]Shen, B., Chang, L., Liu, J., Wang, H., Yang, Q.-F., Xiang, C., Wang, R. N., He, J., Liu, T., Xie, W., Guo, J., Kinghorn, D., Wu, L., Ji, Q.-X., Kippenberg, T. J., Vahala, K. & Bowers, J. E. Integrated Turnkey Soliton Microcombs. Nature 582, 365–369 (2020).DOI
  32. [32]Xiang, C., Liu, J., Guo, J., Chang, L., Wang, R. N., Weng, W., Peters, J., Xie, W., Zhang, Z., Riemensberger, J., Selvidge, J., Kippenberg, T. J. & Bowers, J. E. Laser Soliton Microcombs Heterogeneously Integrated on Silicon. Science 373, 99–103 (2021).DOI
  33. [33]Ulanov, A. E., Wildi, T., Pavlov, N. G., Jost, J. D., Karpov, M. & Herr, T. Synthetic Reflection Self-Injection-Locked Microcombs. Nature Photonics 18, 294–299 (2024).
  34. [34]Wildi, T., Ulanov, A. E., Voumard, T., Ruhnke, B. & Herr, T. Phase-Stabilised Self-Injection-Locked Microcomb. Nature Communications 15, 7030 (2024).
  35. [35]Marin-Palomo, P., Kemal, J. N., Karpov, M., Kordts, A., Pfeile, J., Pfeiffer, M. H. P., Trocha, P., Wolf, S., Brasch, V., Anderson, M. H., Rosenberger, R., Vijayan, K., Freude, W., Kippenberg, T. J. & Koos, C. Microresonator-Based Solitons for Massively Parallel Coherent Optical Communications. Nature 546, 274–279 (2017).
  36. [36]Suh, M.-G., Yi, X., Lai, Y.-H., Leifer, S., Grudinin, I. S., Vasisht, G., Martin, E. C., Fitzgerald, M. P., Doppmann, G., Wang, J., Mawet, D., Papp, S. B., Diddams, S. A., Beichman, C. & Vahala, K. Teaching for Exoplanets Using a Microresonator Astrocomb. Nature Photonics 13, 25–30 (2019).
  37. [37]Obrzud, E., Rainer, M., Harutyunyan, A., Anderson, M. H., Liu, J., Geiselmann, M., Chazelas, B., Kundermann, S., Lecomte, S., Cecconi, M., Ghedina, A., Molinari, E., Pepe, F., Wildi, F., Bouchy, F., Kippenberg, T. J. & Herr, T. A Microphotonic Astrocomb. Nature Photonics 13, 31–35 (2019).arxiv.org/abs/1712.09526
  38. [38]Suh, M.-G., Yang, Q.-F., Yang, K. Y., Yi, X. & Vahala, K. J. Microresonator Soliton Dual-Comb Spectroscopy. Science 354, 600–603 (2016).
  39. [39]Tetsumoto, T., Nagatsuma, T., Fermann, M. E., Navickaite, G., Geiselmann, M. & Rolland, A. Optically Referenced 300 GHz Millimetre-Wave Oscillator. Nature Photonics 15, 516–522 (2021).DOI
  40. [40]Zhang, S., Silver, J. M., Shang, X., Del Bino, L., Ridler, N. M. & Del’Haye, P. Terahertz wave generation using a soliton microcomb. Optics express 27, 35257–35266 (2019).DOI
  41. [41]Wang, B., Morgan, J. S., Sun, K., Jahanbozorgi, M., Yang, Z., Woodson, M., Estrella, S., Beling, A. & Yi, X. Towards High-Power, High-Coherence, Integrated Photonic mmWave Platform with Microcavity Solitons. Light: Science & Applications 10, 4 (2021).DOI
  42. [42]Kuse, N., Nishimoto, K., Tokizane, Y., Okada, S., Navickaite, G., Geiselmann, M., Minoshima, K. & Yasui, T. Low Phase Noise THz Generation from a Fiber-Referenced Kerr Microresonator Soliton Comb. Communications Physics 5, 312 (2022).DOI
  43. [43]Peters, L., Cutrona, A., Cooper, A. R., Olivieri, L., Getman, F., Cecconi, V., Paul, N., Das, D., Rowley, M., Chu, S. T., Little, B. E., Morandotti, R., Moss, D. J., Totero Gongora, J. S., Pasquazi, A. & Peccianti, M. Millimetre-Wave Comb Generated by an Optical Microcomb. Nature Communications 17, 9833 (2026).DOI
  44. [44]Jang, J. K., Klenn er, A., Ji, X., Okawachi, Y., Lipson, M. & Gaeta, A. L. Synchronization of Coupled Optical Microresonators. Nature Photonics 12, 688–693 (2018).DOI
  45. [45]Yang, Q.-F., Shen, B., Wang, H., Tran, M., Zhang, Z., Yang, K. Y., Wu, L., Bao, C., Bowers, J., Yariv, A. & Vahala, K. Vernier Spectrometer Using Counterpropagating Soliton Microcombs. Science 363, 965–968 (2019).DOI
  46. [46]Moille, G., Stone, J., Chojnacky, M., Shrestha, R., Javid, U. A., Menyuk, C. & Srinivasan, K. Kerr-induced synchronization of a cavity soliton to an optical reference. Nature 624, 267–274 (2023).DOI
  47. [47]Wildi, T., Ulanov, A., Englebert, N., Voumard, T. & Herr, T. Sideband Injection Locking in Microresonator Frequency Combs. APL Photonics 8, 120801 (2023).DOI
  48. [48]Ulanov, A. E., Ruhnke, B., Wildi, T. & Herr, T. Attosecond-Level Synchronisation of Chip-Integrated Oscillators 2025. arXiv: 2510.11630 [physics].arxiv.org/abs/2510.11630
  49. [49]Ulanov, A. E., Bengel, L., Ruhnke, B., Sakharova, A. & Herr, T. Bright solitons in hybrid-dispersion photonic crystal microresonators 2026. arXiv: 2607 . 06406 [physics.optics].arxiv.org/abs/2607.06406
  50. [50]Liebermeister, L., Nellen, S., Kohlhaas, R. B., Lauck, S., Deumer, M., Breuer, S., Schell, M. & Globisch, B. Optoelectronic frequency-modulated continuous-wave terahertz spectroscopy with 4 THz bandwidth. Nature Communications 12, 1071 (2021).DOI
  51. [51]Jepsen, P. U. Phase Retrieval in Terahertz Time-Domain Measurements: a "how to" Tutorial. Journal of Infrared, Millimeter, and Terahertz Waves 40, 395–411 (2019).DOI
  52. [52]Dai, J., Zhang, J., Zhang, W. & Grischkowsky, D. Terahertz time-domain spectroscopy characterization of the far-infrared absorption and index of refraction of high-resistivity, float-zone silicon. Journal of the Optical Society of America B 21, 1379–1386 (2004).DOI
  53. [53]Gaafar, M. A., Ludwig, M., Wang, K., Wildi, T., Voumard, T., Sinobad, M., Lorenzen, J., Francis, H., Carreira, J., Zhang, S., Bi, T., Del’Haye, P., Geiselmann, M., Singh, N., Kärntner, F. X., Garcia-Blanco, S. M. & Herr, T. Femtosecond Pulse Amplification on a Chip. Nature Communications 15, 8109 (2024).
  54. [54]Zeng, T., Masselink, E. W., Wu, T.-H., Brooks, N., Chang, P., Spektor, G., Newman, Z. L., Liu, D., Papp, S. B., Carlson, D. R., Diddams, S. A. & Yang, K. Integrated Ytterbium Gain for Visible-near-Infrared Photonics 2026. arXiv: 2605 . 13828 [physics.optics].arxiv.org/abs/2605.13828
  55. [55]Tan, D. T. H., Sun, P. C. & Fainman, Y. Monolithic Nonlinear Pulse Compressor on a Silicon Chip. Nature Communications 1, 116 (2010).pubmed.ncbi.nlm.nih.gov/21081914
  56. [56]Sinobad, M., Molteni, F., Gehrmann, P., Lorenzen, J., Hammer, D. N., Gaafar, M. A., Herr, T., Singh, N. & Kärntner, F. X. Dispersion Compensating Silicon Nitride Waveguide Bragg Gratings for Ultrashort Pulse Compression in CLEO 2025 (Optica Publishing Group, 2025), A1424_3.DOI
  57. [57]Nellen, S., Lauck, S., Schwanke, G., Deumer, M., Kohlhaas, R. B., Liebermeister, L., Schell, M. & Globisch, B. Radiation pattern of planar optoelectronic antennas for broadband continuous-wave terahertz emission. Optics Express 29, 8244–8257 (2021).DOI
  58. [58]Gaier, A., Mamian, K., Rajabali, S., Lampert, Y., Liu, J., Magalhaes, L., Shams-Ansari, A., Loncar, M. & Benea-Chelmus, I. -.- Wireless millimeter-wave electro-optics on thin film lithium niobate 2025. arXiv: 2505.04585 [physics.optics].arxiv.org/abs/2505.04585
  59. [59]Rajabali, S. & Benea-Chelmus, I.-C. Present and future of terahertz integrated photonic devices. en. APL Photonics 8 (2023).DOI
  60. [60]Deumer, M., Nellen, S., Lauck, S., Keyvaninia, S., Berrios, S., Kieper, M., Schell, M. & Kohlhaas, R. B. Ultra-wide-band PIN-PD THz emitter with > 5.5 THz bandwidth. Journal of Infrared, Millimeter, and Terahertz Waves 45, 831–840 (2024).DOI
  61. [61]Kohlhaas, R., Breuer, S., Nellen, S., Liebermeister, L., Schell, M., Semtsiv, M., Masselink, W. & Globisch, B. Photoconductive terahertz detectors with 105 dB peak dynamic range made of rhodium doped InGaAs. Applied Physics Letters 114 (2019).DOI

Paper details

vlnc:W_aysnvjaj
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents