WorksPhysics and Astronomy
Spectrum averaged cross section measurements of lutetium using standard 252Cf neutron source
Abstract
The spectrum averaged cross section (SACS) in standard neutron field is a preferable tool for cross section validation. There are very few measurements involving lutetium neutron cross sections. The presented work uses only neutron standard, i.e., 252Cf(sf) neutron field, for validation of lutetium threshold cross sections. SACS were inferred from gamma spectrometry derived reaction rates. The SACS which were derived include 175Lu(n,2n)174Lu, 175Lu(n,3n)173Lu, 175Lu(n,p)175Yb, and 176Lu(n,n)176m1Lu reactions. All these reactions SACS were measured for the first time. MCNP6 calculations using JEFF-3.3 or ENDF/B-VIII.0 libraries for lutetium cross sections were compared with experimental data. The agreement was found very poor for all reactions under study. Thus there is a need for their improvement. The presented data can be also used for validation of the various theoretical models.
Introduction
Lutetium is a rare last element in the lanthanide series. Natural lutetium consists of two isotopes, (97.401%) and (2.599%). Isotope is radioactive, having a half-life of 3.78E10 years. This isotope and its ratio to its decay product is used to geochronical dating of minerals and rocks. , having a relatively high cross-section for (n,xn) reactions, is present in the NEA Nuclear Data High Priority Request List [7] with a possibility to be used for dosimetry purposes. Despite this fact, the differential experimental data on lutetium are scarce; furthermore, the integral data are entirely missing. This work deals with the measurement of lutetium spectrum averaged cross sections (SACS), which is an integral quantity useful for validation. The presented experimental data for lutetium will help to complement incomplete nuclear data. Due to the well known neutron spectrum, being primary neutron standard, these data also can help to understand the nuclear reaction mechanisms and, in general, neutron-nuclear interactions. Also, it can be helpful for testing different theoretical models; for example statistical model (Dzyusiuk et al., 2010). The neutron standard was used for validation of lutetium threshold cross sections. The investigated SACS include , , , and reactions. The methodology of SACS evaluation and source handling was successfully validated in previously published papers such as (Schulc et al. 2018a, Schulc et al. 2019a, Schulc et al. 2019b, and Schulc et al. 2020).
Description of the experimental setup and evaluations
The used neutron source, , had an average total emission of 1.93E8 n/s during lutetium irradiation. The source emission was derived from the data in the Certificate of Calibration received from the National Physical Laboratory, United Kingdom. The thin nickel foils were attached in front of and behind the lutetium foil as a neutron flux monitor due to the complicated geometry. The agreement between nickel inferred emission and calculated emission was found. The lutetium activation foil (2.5 cm × 2.5 cm, 0.1 cm thick) was attached to the surface of the irradiation tube to achieve maximal neutron flux, see Figure 1 for the experimental setup. The centre of the source in the tube was leveled with a centre of the foil. Irradiation of the lutetium took almost 99 days continuously. After the irradiation, the foil was subsequently measured on the upper cap of the high-purity germanium detector. The efficiency curve of the detector was determined calculationally using validated MCNP6.2 (Goorley et al., 2012) model, see (Kostal et al. 2017). The gamma spectrum acquisition took almost 4 days. Table 1 summarizes the parameters of the irradiation and gamma spectrometry. Table 2 displays measured and evaluated gamma lines of the activation products, their emission probabilities, and their half-lives.

Figure 1. Lutetium foil irradiation setup.
| Reaction | Irradiation time | Cooling time | Measurement time |
| All reactions | 98.91 days | 10 minutes | 3.84 days |
Table 1. Parameters of irradiation and following HPGe measurement.
| Reaction | Half-life | Gamma Energy [MeV] | Gamma emission probability |
| 3.31 years | 1.241847 | 5.14% | |
| 142 days | 0.067058 | 7.25% | |
| 1.37 years | 0.272105 | 21.2% | |
| 4.185 days | 0.396329 | 13.2% | |
| 3.664 hours | 0.088361 | 8.9% |
Table 2. Parameters of the investigated neutron-induced threshold reactions.
The experimental reaction rate was calculated from the measured gamma line net peak area using formula
where: is the experimental reaction rate per atom per second, is the number of target isotope nuclei, is the detector efficiency, is gamma branching ratio, is the decay constant, characterizes the abundance of isotope of interest in the target and its purity, is the time between the end of irradiation and start of HPGe measurement, is the measured number of counts, is the real time of measurement by HPGe, is the live time of measurement by HPGe (it is time of measurement corrected to the dead time of the detector), and is the time of irradiation. The coincidence summing was estimated to be sufficiently low and, therefore, it was neglected.
The SACS is derived from reaction rate by correction factor which considers the spectral shift effect, flux loss and self-shielding together. The correction is computed by means of MCNP6 as a ratio between the SACS in the real set-up and the SACS in the same set-up consisting of void cells. The SACS is derived via Equation (2):
where denotes the correction factor, is the calculated neutron spectrum, is the cross section and is the spectral averaged cross section. The numerator corresponds to the measured reaction rate according to the Equation (1).
The uncertainty analysis includes non-negligible uncertainties: uncertainty in the position of the sample, emission and the position of the source, statistical uncertainty of the net peak area, and the calculated germanium detector efficiency uncertainty, details can be found in (Schulc et al. 2019b).
MCNP6.2 software was used for all calculations. The base transport libraries were taken from ENDF/B-VII.1 (Chadwick et al. 2011). Lutetium cross-section was taken either ENDF/B-VIII.0 (Brown et al. 2018) or JEFF-3.3 (Plompen et al., 2020). The input neutron spectrum was taken from [6]. The calculations were performed using all dimensions, densities, and materials.
Results
Figure 2 shows the comparison of reaction cross-section with the experimental data available in the EXFOR database. Figure 3 displays the energy distribution of the reaction rate for in JEFF-3.3 and ENDF/B-VIII.0 libraries. The distribution in both libraries is similar. The cross-section in both libraries is also similar in the region under 14 MeV, i.e. the most sensible energy region. The calculation in both libraries gives a similar result and overestimates the experiment around 20 %. The reaction SACS in was derived as 7.02 0.26 mb. This result was obtained as the sum of SACS of and because both channels were measured (see Table 2).
Figure 2. Comparison of reaction cross-section with the EXFOR data, JEFF-3.3 and ENDF/B-VIII.0 libraries.
Figure 3. Energy distribution of the reaction rate for in JEFF-3.3 and ENDF/B-VIII.0 libraries.
In the case of the reaction, Figure 4 shows the reaction cross-section. JEFF-3.3 library differs significantly from the ENDF/B-VIII.0 library. JEFF-3.3 library follows EXFOR data, unlike ENDF/B-VIII.0. Figure 5 shows the reaction rate contribution of reaction.
Figure 4. Comparison of reaction cross-section with the EXFOR data, JEFF-3.3 and ENDF/B-VIII.0 libraries.
Figure 5. Energy distribution of the reaction rate for in JEFF-3.3 and ENDF/B-VIII.0 libraries.
The distributions differ; however, a maximal response is in the same energy bin for both libraries (17-18 MeV). The agreement with the experiment is not satisfactory, the JEFF-3.3 library underestimates the experiment around 75 % and the ENDF/B-VIII.0 library around 45 %. The SACS for the reaction in the spectrum was derived as 0.131 0.008 mb.
Concerning reaction, Figure 6 shows its cross-section. Evaluations in JEFF-3.3 and ENDF/B-VIII.0 are significantly different. The same situation is also for the reaction rate distribution depicted in Figure 7. Note that data in the EXFOR database are contradictory. It is apparent that the JEFF-3.3 and ENDF/B-VIII.0 are based on different EXFOR experimental data. The agreement of the present experiment with calculation is very bad, -83 % in the case of JEFF-3.3 library and approximately 725 % for ENDF/B-VIII.0 library. reaction SACS value is the lowest from all studied reactions, i.e. 6.81E-02 ± 0.23E-02 mb.
Figure 6. Comparison of reaction cross-section with the EXFOR data, JEFF-3.3 and ENDF/B-VIII.0 libraries.

Figure 7. Energy distribution of the reaction rate for in JEFF-3.3 and ENDF/B-VIII.0 libraries.
The last explored reaction was reaction. In this case, the unexcited isotope has gamma line of very similar energy as its first excited state (unexcited 0.08834 MeV and excited 0.088361 MeV). The natural activity was subtracted from measured activity in the SACS evaluation. The cross-section leading to first excited state was not found in any library, neither any data in EXFOR. Nevertheless, still some results can be inferred from inelastic cross section (leading to all excited states). Comparison of measured with calculated gives C/E-1 ratio around -70 %. This fact means that inelastic cross-section is necessarily inconsistent with the experiment. Figure 8 compares reaction in available libraries. reaction SACS value was estimated as 7.10E03 ± 0.22E3 mb.

Figure 8. Comparison of reaction cross-section in JEFF-3.3 and ENDF/B-VIII.0 libraries.
Conclusions
Table 3 summarizes experimental and calculated reaction rates for all reactions. The performed experiment reveals unsatisfactory agreement with any libraries cross-section for lutetium neutron induced threshold reactions. These cross-sections need further improvement and more experiments dealing with lutetium to be performed. All SACS were measured for the first time.
| Q [s atom neutron] | C/E-1 | Uncertainty | |
| EXPERIMENT | 2.00E-28 | 3.7% | |
| JEFF-3.3 | 2.45E-28 | 22.26% | |
| ENDF/B-VIII.0 | 2.39E-28 | 19.10% | |
| EXPERIMENT | 3.74E-30 | 5.8% | |
| JEFF-3.3 | 9.31E-31 | -75.14% | |
| ENDF/B-VIII.0 | 2.05E-30 | -45.35% | |
| EXPERIMENT | 1.94E-30 | 3.4% | |
| JEFF-3.3 | 3.30E-31 | -83.04% | |
| ENDF/B-VIII.0 | 1.60E-29 | 725.01% | |
| EXPERIMENT | 2.27E-25 | 3.1% |
Table 3. Calculation and C/E-1 comparison for neutron induced threshold reactions in lutetium.
Acknowledgement
Presented results were obtained with the use of infrastructure Reactors LVR-15 and LR-0, which is financially supported by the Ministry of Education, Youth and Sports – project LM2018120 and the SANDA project funded under H2020-EURATOM-1.1 contract 847552.
References
- [6]Mannhart 2008, W. Mannhart, “Status of the Evaluation of the Neutron Spectrum of ²⁵²Cf(sf)”, IAEA Technical Report INDC(NDS)-0540, IAEA, Vienna (2008). Presentation available at www-nds.iaea.org/standards-cm-oct-2008/6.PDF
- [7]Plompen, A. et al. (2007), J. M. Plompen et al., "The NEA High Priority Nuclear Data Request List for future needs", International Conference on Nuclear Data for Science and Technology, Nice, France, 22-27 April 2007, June 2008, EDP Sciences, pp. 765-768, doi: doi.org/10.1051/ndata:07419.DOI