betaFeedback

WorksPhysics and Astronomy

CHRONOS: Cryogenic sub-Hz cROss torsion bar detector with quantum NOn-demolition Speed meter

Abstract

We propose a next-generation ground-based gravitational-wave detector, Cryogenic sub-Hz cROss torsion-bar detector with quantum NOn-demolition Speed meter (CHRONOS), optimized for the unexplored 0.10.1-10 Hz10\,\mathrm{Hz} band between the space-based LISA and future ground-based detectors such as Cosmic Explorer and the Einstein Telescope. CHRONOS combines a ring-cavity Sagnac interferometer with torsion-bar test masses to realize the first quantum nondemolition (QND) measurement of angular momentum in a macroscopic system. By implementing a speed-meter readout in the rotational degree of freedom, CHRONOS coherently cancels quantum radiation-pressure noise and enables sub-Hz observations. We calculate, for the first time, that detuned power-recycling and cavity-length optimization can simultaneously relax technical requirements on both torsion bars and speed meters. Assuming a realistic optical design with 1m torsion bar, we estimate strain sensitivities of h≃5×10−19 Hz−1/2h \simeq 5\times10^{-19}\,\mathrm{Hz^{-1/2}} at 2 Hz2\,\mathrm{Hz} for detectors with arm lengths of 2.52.5 m, 4040 m, and 300300 m. These sensitivities enable (i) direct detection of intermediate-mass black hole binaries up to 340,Mpc with SNR=3, (ii) probing SGWB down to ΩGW∼ 3×10−4Ω_{\mathrm{GW}}\sim\ 3\times10^{-4} at 0.2 Hz with 5 year accumulation. Furthermore, CHRONOS enable to prompt detection of gravity-gradient signals from M 5.5 earthquakes even with a 2.52.5 m prototype. CHRONOS thus opens new opportunities for quantum-limited geophysical observation and multi-band, multi-messenger gravitational-wave astronomy.

Introduction

The first direct detection of gravitational waves (GWs) by LIGO [1] opened the era of GW astronomy, followed by Virgo [2] and KAGRA [3], which operate above 10 Hz and have provided key insights into compact binaries and fundamental physics. At much lower frequencies, space-based missions such as LISA [4] will explore the millihertz band (10−410^{-4}–10−110^{-1} Hz), targeting supermassive black hole mergers and cosmological signals.

However, the intermediate range of ∼0.1\sim0.1–10 Hz remains largely unexplored despite its rich science potential, including intermediate-mass black hole (IMBH) binaries, stochastic gravitational-wave backgrounds (SGWBs), and prompt gravity-gradient signals from seismic events. Bridging this sensitivity gap requires fundamentally new detection principles.

Torsion-bar-based detectors such as TOBA [5] and TorPeDO [6] demonstrated sub-Hz feasibility but the fundamental quantum back-action limits in displacement readout, requiring massive test masses for ensuring sensitivity below 1 Hz [5].

We propose Cryogenic sub-Hz cROss torsion-bar detector with quantum NOn-demolition Speed meter (CHRONOS), a next-generation detector combining a triangular Sagnac interferometer with torsion-bar test masses to realize the first quantum nondemolition (QND) measurement of angular momentum in a macroscopic system [7, 8]. QND is a system that can break the trade-off between shot noise and back-action noise arising from quantum commutation relations, and it has been reported that this can be realized through squeezing techniques [9, 10] and speed meters [11, 12, 13].

A novel speed-meter readout cancels radiation-pressure noise, and power-recycling mirror detuning further suppresses the low-frequency noise with coating losses. These issues represent technical challenges for enhancing the sensitivity of torsion bars and for the first demonstration of a speed meter, and addressing them with a speed meter and a dual-recycled torsion-bar system is a unique approach.

In this paper, we explicitly evaluate the sensitivity for different test facility scales: a 2.5 m arm length, corresponding to a Glasgow-type 10 m interferometer [14]; a 40 m arm length [15], corresponding to the Caltech 40 m interferometer; and a 300 m arm length, corresponding to the TAMA300 [16, 17, 18].

Detector Concept

The CHRONOS detector introduces a new paradigm for low-frequency GW detection by combining torsion-bar test masses, triangular ring cavities, and a dual-recycled Sagnac interferometer. Torsion-based detectors such as TOBA [5] and TorPeDO [6] have demonstrated sub-Hz angular displacement measurements θ\theta by exploiting correlated torsion-bar motion. In these systems, the response of a torsion bar in the xx–yy plane with moment of inertia I=∫ρ(x2+y2)dVI = \int\rho(x^2+y^2)dV is obtained as θ(Ω)=η(h+F++h×F×)\theta(\Omega) = \eta(h_+F_+ + h_\times F_\times), where GW polarizations h+,×h_{+,\times}, antenna patterns F+,×F_{+,\times}, and geometrical factor η=I/∫ρ(x2−y2)dV\eta= I/\int\rho(x^2-y^2)dV are assumed. The test-mass density ρ\rho and volume VV are assumed. The signal sideband frequency is obtained with Ω\Omega. For all cases, we assume identical torsion-bar geometries with length of torsion bar Lbar=1 mL_{\mathrm{bar}} = 1\ \mathrm{m}, moment of inertia I=19.9 kg m2I = 19.9\ \mathrm{kg\ m^2}, test-mass mass M=171 kgM = 171\ \mathrm{kg}, test-mass temperature T=10 KT = 10\ \mathrm{K}, and a geometrical factor η=0.936\eta= 0.936. Assuming the torsional resonance lies well below the observation band, these schemes are fundamentally limited by quantum radiation-pressure back-action noise below 1 Hz.

Figure 1 shows the CHRONOS optical configuration. Two orthogonal torsion bars are suspended in a cross geometry, each hosting a triangular ring-cavity. After pre-isolation, the input beam passes through an input mode cleaner and is split at the input beam splitter (IBS). The beams enter the XX and YY arms, each forming a dual-recycled speed-meter cavity with a power-recycling mirror (PRM) as PRMY1and PRMX1, and signal-recycling mirror (SRM) as SRMY1and SRMX1. Outputs are recombined at the output beam splitter (OBS), filtered by an output mode cleaner, and read out via balanced homodyne detection. The detailed optical design of CHRONOS is described in Inoue et al. [19]. As the XX and YY arms are identical, we focus on the YY arm below.

Optical configuration of CHRONOS

Figure 1. Optical configuration of CHRONOS. The Sagnac interferometer integrates: (i) torsion-bar test masses at the center, (ii) Ring cavity with Sagnac interferometer at both arm, (iii) dual-recycled cavities with SRM and PRM.

CHRONOS overcomes the limitations of conventional differential angle readout by directly measuring the conjugate angular momentum LL. This enables, for the first time, a QND measurement of LL in a macroscopic system with O(100 kg)O(100\ \mathrm{kg}) test masses.

As shown in Figure 1, counter-propagating beams circulate in a triangular cavity formed by ETMLY–MTMLY–ITMLY and ETMRY–MTMRY–ITMRY, and are separated at BSY. The optical path delay between the two beams provides direct access to the angular momentum through L(t)∝θ(t+τ)−θ(t)τL(t) \propto\frac{\theta(t+\tau)-\theta(t)}{\tau}, where τ\tau denotes the optical delay time.

In a conventional differential angle readout, the time derivative of the angle satisfies θ˙∝[θ˙,H^]≠0\dot{\theta} \propto[\dot{\theta},\hat{H}] \ne0, implying that the future evolution of θ\theta is disturbed by measurement back-action. In contrast, the angular momentum satisfies L˙∝[L^,H^]=0\dot{L} \propto[\hat{L},\hat{H}] = 0, ensuring that LL is unaffected by the measurement. Consequently, [L^(t),L^(t′)]=0[\hat{L}(t),\hat{L}(t')] = 0, demonstrating that LL is a QND observable.

QND is a system that can break the trade-off between shot noise and back-action noise arising from quantum commutation relations, and it has been reported that this can be realized through squeezing techniques [7, 9, 10] and speed meters [8, 12, 13]. By circumventing the quantum trade-off between shot noise and radiation-pressure noise [20, 21], these approaches provide a unique pathway toward surpassing the conventional quantum limits in GW detectors.

Noise Budget and Sensitivity

We evaluate the sensitivity of CHRONOS using both an analytical quantum-operator approach and full simulations performed with FINESSE3 [22]. The unique aspects of this study are the implementation of power recycling cavity (PRC) detuning and the integration of a speed-meter topology with torsion-bar test masses. Balanced homodyne detection is assumed throughout this study. [23]. Following the Buonanno-Chen formalism [24, 25, 26, 27, 28], we use the two-photon representation [7]. In this method, we define the input and output quadrature vectors as a=(a1 a2)t\boldsymbol{a} = (a_1\ a_2)^{\mathsf{t}} and b=(b1 b2)t\boldsymbol{b} = (b_1\ b_2)^{\mathsf{t}}, where the input quadrature vector of the interferometer a\boldsymbol{a} is denoted. Following the generalized framework of Buonanno and Chen incorporating detuning terms for both the power-recycling cavity (PRC) and the signal-recycling cavity (SRC),

\boldsymbol{b} = \frac{1}{M}\left[e^{2i(\beta_{\mathrm{sag}+\Phi_{\mathrm{s}})}C\boldsymbol{a}+\sqrt{2\mathcal{K}_{\mathrm{sag}}}\,t_{\mathrm{s}}e^{i(\beta_{\mathrm{sag}+\Phi_{\mathrm{s}})}}D\frac{\theta}{\theta_{\mathrm{SQL}}}\right]} \tag*{(1)}

where time delay of SR cavity is defined as Φs\Phi_{\mathrm{s}}, and the effective Sagnac phase shift is βsag=2β+π/2\beta_{\mathrm{sag}} = 2\beta+\pi/2 [29] the angular displacement noise can be expressed as

θ=θSQL2(1−rs2)KsagνTGννTQν(2)\theta= \frac{\theta_{\mathrm{SQL}}}{\sqrt{2(1-r_{\mathrm{s}}^2)\mathcal{K}_{\mathrm{sag}}}}\sqrt{\frac{\boldsymbol{\nu}^{\mathsf{T}}G\boldsymbol{\nu}}{\boldsymbol{\nu}^{\mathsf{T}}Q\boldsymbol{\nu}}} \tag*{(2)}

where the standard quantum limit (SQL) of angular displacement noise [5] is calculated as θSQL=2ℏ/(IΩ2)\theta_{\mathrm{SQL}} = \sqrt{2\hbar/(I\Omega^2)}. The homodyne detection vector νT=(cos⁡ζ,sin⁡ζ)\boldsymbol{\nu}^{\mathsf{T}} = (\cos\zeta,\sin\zeta) is defined by the homodyne angle ζ\zeta. The amplitude reflectivity of the

SRM is defined as rsr_s. We define G=CCTG = CC^{\mathrm{T}}, and Q=ℜ(D)ℜ(D)T+ℑ(D)ℑ(D)TQ = \Re(D)\Re(D)^{\mathrm{T}} + \Im(D)\Im(D)^{\mathrm{T}}, where the matrix C=[cij]C = [c_{ij}] and the column vector DT=(D1,D2)D^{\mathrm{T}} = (D_1, D_2) are defined following Eqs. (2.22)–(2.24) of Ref. [24].

The optomechanical coupling factor κ\kappa defined in [24, 26, 30, 31] is modified as κsag=4κ∣HPRC∣2sin⁡2βsag\kappa_{\mathrm{sag}} = 4\kappa\lvert H_{\mathrm{PRC}}\rvert^2 \sin^2 \beta_{\mathrm{sag}}, where transfer function of PRC is

HPRC=tp1−irp∣rifo∣sin⁡βsage2i(ϕp+τpΩ)(3)H_{\mathrm{PRC}} = \frac{t_p}{1 - i r_p \lvert r_{\mathrm{ifo}}\rvert\sin\beta_{\mathrm{sag}} e^{2i(\phi_p+\tau_p\Omega)}} \tag*{(3)}

The amplitude transmission tpt_p and reflection coefficients rpr_p of the PRC mirror are assumed. rifor_{\mathrm{ifo}} is the effective complex reflectivity of the interferometer, including SRC detuning and internal losses. PRC detuning phase and one-way propagation time are obtained with ϕp\phi_p and τp\tau_p. The above expression can be diagonalized along the principal axes:

2.5 m40 m300 m
RsR_s, RpR_p, RiR_i0.5, 0.9, 0.99990.5, 0.95, 0.9990.5, 0.99, 0.995
PinP_{\rm in}, ParmP_{\rm arm}1 W, 444 W20 W, 2391 W100 W, 18.3 kW
ϕp\phi_p, ϕs\phi_s, ζ\zeta−85∘-85^\circ, 0∘0^\circ, 46∘46^\circ26∘26^\circ, 0∘0^\circ, −50∘-50^\circ41∘41^\circ, 2∘2^\circ, −66∘-66^\circ
FringF_{\rm ring}3.14×1043.14 \times10^43.14×1033.14 \times10^36.27×1026.27 \times10^2
ww at ETM2 mm20 mm35 mm

Table 1. Parameters for sensitivity estimates. Definitions: Ri=ri2R_i = r_i^2, Rp=rp2R_p = r_p^2, Rs=rs2R_s = r_s^2; PinP_{\rm in} input power, ParmP_{\rm arm} arm power; ϕp\phi_p PRC detuning, ϕs\phi_s SRC detuning, ζ\zeta homodyne angle; FringF_{\rm ring} finesse, ww beam radius at ETM.

θ=θSQL2Γ(ϕs,ζ)κsag=1+(cot⁡ζeff−κeff)2,(4)\theta= \frac{\theta_{\rm SQL}}{\sqrt{2\Gamma(\phi_s,\zeta)\kappa_{\rm sag}}} = \sqrt{1+\left(\cot\zeta_{\rm eff}-\kappa_{\rm eff}\right)^2}, \tag*{(4)}

where Γ(ϕs,ζ)=(1−rs2)∣D1∣2∣D2∣2−ℜ(D1D2∗)2\Gamma(\phi_s,\zeta) = (1-r_s^2)\sqrt{|D_1|^2|D_2|^2-\mathop{\Re}(D_1D_2^*)^2}, and the effective optomechanical coupling derived from GG and QQ is

κeff=Q22G11+Q11G22−2Q12G12det⁡Qdet⁡G−2.(5)\kappa_{\rm eff} = \sqrt{\frac{Q_{22}G_{11}+Q_{11}G_{22}-2Q_{12}G_{12}}{\sqrt{\det Q}\sqrt{\det G}}}-2. \tag*{(5)}

The effective homodyne angle is given by ζeff=ζ−ψ(f)+θ(f)\zeta_{\rm eff}=\zeta-\psi(f)+\theta(f), where ψ(f)\psi(f) and θ(f)\theta(f) denote the principal-axis rotations of GG and QQ, respectively. We evaluate the strain sensitivity for three detector scales optimized for the sub-Hz regime, with the design parameters chosen such that the sensitivity peaks around 1 Hz. A systematic optimization study of the interferometer parameters—specifically the detuning angle, homodyne angle, and optical coating properties, optimization study for each parameter, and definition of each noise—has been carried out in Inoue et al. and Tanabe et al. [19, 32]. Seismic noise and Newtonian noise are estimated assuming an underground environment, based on measured ground motion data at the Kamioka site [33]. For the Newtonian noise, we assume that the dominant contribution arises from Rayleigh waves propagating along the ground surface. Figure 2 shows the resulting sensitivity curves for the three detector scales considered in this study, corresponding to arm lengths of 2.5 m, 40 m, and 300 m. In all cases, the interferometer parameters are optimized to target sub-Hz observations, with the peak sensitivity tuned to approximately 1 Hz. Each panel displays the individual noise contributions—quantum noise, coating thermal noise, bar thermal noise, seismic noise, and Newtonian noise—together with the total noise obtained by summing these components.

Predicted CHRONOS strain sensitivity and noise contributions

Figure 2. Predicted CHRONOS strain sensitivity (black) and noise contributions for 2.5m, 40m and 300m cases.

For the 2.5 m arm-length configuration, the sensitivity at low frequencies is dominated by seismic noise, while quantum noise limits the performance in the frequency range of approximately 0.1–1 Hz. At frequencies above 1 Hz, coating thermal noise become the primary limiting factors. Extending the arm length to 40 m significantly reduces both quantum noise and bar thermal noise, leading to a substantial improvement in sensitivity over a range from 0.3 to 10 Hz. Although Newtonian noise remains an important limitation at the lowest frequencies, noise contributions originating from the detector itself are considerably suppressed at this scale.

For the 300 m arm-length configuration, quantum noise and bar thermal noise are further suppressed across the sub-Hz to few-Hz band. This result highlights that, while scaling up the detector size is highly effective in reducing internal noise sources in torsion-bar GW detectors, environmental gravity noise ultimately emerges as the dominant sensitivity limitation. Overall, these results demonstrate that the combination of QND techniques and a speed-meter configuration in CHRONOS, together with detector scaling, enables effective suppression of quantum noise and internal thermal noise in the sub-Hz band. Achieving further sensitivity improvements will require advances in Newtonian noise mitigation strategies as well as the development of lower-loss optical coating technologies. Extending the arm length shifts the radiation-pressure noise crossover frequency toward lower frequencies, enhancing low-frequency performance. Assuming a coating loss of 0.1 ppm quantum noise is strongly suppressed compared to conventional designs; in an ideal lossless system, the suppression is even more significant. Increasing the arm length also improves the effective optical delay while reducing the required finesse, thereby relaxing coating-loss requirements.

A key feature of CHRONOS is its use of PRC detuning in Eq. (3), which differs from the conventional approach of detuning the SRM. Focusing on the PRC transfer function, the detuning angle of the PRC acts simultaneously on both the clockwise (CW) and counter-clockwise (CCW) components of the Sagnac speed meter [29]. This phase shift propagates into the effective homodyne angle, ζeff\zeta_{\rm eff} as a term arg⁡(Hprc)\arg(H_{\rm prc}), so by controlling the frequency-dependent phase balance of the CW and CCW beams through the PRC, one can effectively impart a frequency-dependent homodyne angle. In addition to enhancing the carrier field and increasing circulating power, PRC detuning enables sensitivity shaping with engineered frequency dependence, thereby suppressing radiation-pressure noise and reducing shot noise.

Scientific Reach

Three science packages are discussed for the scientific outcomes assuming each sensitivity as follows. First, CHRONOS targets IMBH binaries with component masses of 1×1021 \times10^{2}–5×105 M⊙5 \times10^{5}\ M_{\odot} [4, 34, 35, 36]. These signals enter the CHRONOS band weeks to days before coalescence, enabling multi-band observations in synergy with LISA and LIGO [1, 4]. For M∼4×104 M⊙M \sim4 \times10^{4}\ M_{\odot}, CHRONOS can detect mergers up to 340 Mpc340\ \mathrm{Mpc} at SNR=3\mathrm{SNR}=3, allowing the first statistical studies of IMBH populations and insights into supermassive black hole formation as shown in Figure 3. Moreover, at low frequencies, the use of high-finesse cavities causes coating losses that can destroy the QND system. This effect corresponds to the achievable finesse and the time delay τ\tau, but by increasing the arm length, an equivalent time delay can be realized with fewer reflections. As a result, low-frequency QND measurements can be maintained, leading to an increased signal to noise ratio (SNR) for high-mass IMBH binaries.

Estimated SNR for IMBH binary mergers with CHRONOS

Figure 3. Estimated SNR for IMBH binary mergers with CHRONOS.

Second, CHRONOS bridges the sensitivity gap between LISA [4] and ground-based detectors [1], enabling constraints on the SGWB in the 0.10.1–10 Hz10\ \mathrm{Hz} band. Astrophysical foregrounds include unresolved black hole and neutron star binaries, while cosmological sources may arise from first-order phase transitions, cosmic strings, primordial black holes, and inflationary relics [37]. Figure 4 shows the predicted sensitivities by assuming five year of integration. CHRONOS achieves an energy-density sensitivity of ΩGW∼3×10−4\Omega_{\mathrm{GW}} \sim3 \times10^{-4} at 0.2 Hz0.2\ \mathrm{Hz}, enabling new constraints on the search of new SGWB, such as primordial black holes.

Expected sensitivity of CHRONOS to the SGWB

Figure 4. Expected sensitivity of CHRONOS to the SGWB. LIGO O3 [38], LISA pathfinder [39],Sachs Wolfe effect [40],CMB B-mode(r<0.06r < 0.06), CMB Lensing, CMB Temperature [41], show the current observational limit. Binary blackhole and Binary Neutron star (BBH+BNS) [42], Super massive blackhole (SMBH) [43], Primordial Blackhole (PBH) [44, 45], Nambu-Goto type cosmic string (Gμ∼10−8G\mu\sim10^{-8}, σ=0.1\sigma= 0.1) [46, 47, 48], with Primordial Gravitational Wave (PGW) [43] are theoretical predictions.

Finally, CHRONOS enables detection of prompt gravity-gradient signals from large earthquakes as shown in Figure 5. These signals arise from rapid mass redistribution and propagate at the speed of light, potentially allowing detection seconds before destructive surface waves [49, 50, 51]. Simulations for the ASGRAF [52] site near Taipei show high detection efficiency within a 100 km100\ \mathrm{km} radius. Taking into account the density of the ground, the minimum duration time of the arrived surface wave is estimated to be 8.3 sec8.3\ \mathrm{sec}.

Predicted sensitivity to prompt gravity signals from large earthquakes

Figure 5. Predicted sensitivity to prompt gravity signals from large earthquakes. By detecting gravitational perturbations at the speed of light, CHRONOS enables warnings before surface-wave arrival.

Discussion

We investigated how QND techniques can enhance torsion-bar GW detectors. As shown in Figure 6, we performed a direct sensitivity comparison assuming the same moment of inertia, mass, bar length, and bar resonance frequency as those of TOBA. All non-quantum noise contributions were taken to be identical to the model used in Ando et al. [5], ensuring that the difference in sensitivity arises solely from the treatment of quantum noise.

Comparison of the strain sensitivity between TOBA and CHRONOS

Figure 6. Comparison of the strain sensitivity between TOBA and CHRONOS. All non-quantum noise contributions are assumed to be identical to those in Ando et al. [5]. The TOBA quantum noise is limited by the standard quantum limit, whereas CHRONOS employs a speed-meter configuration with a 10 m bar length, enabling broadband sensitivity improvement.

The quantum noise of TOBA is constrained by the SQL, leading to a characteristic knee frequency determined by the trade-off between shot noise and radiation-pressure back-action noise. Improving the high-frequency sensitivity of TOBA requires increasing the laser power to suppress shot noise; however, this unavoidably enhances radiation-pressure noise, thereby degrading the low-frequency sensitivity. In contrast, CHRONOS adopts a speed-meter configuration, which enables the suppression of shot noise and bar thermal noise while maintaining radiation-pressure noise at a comparable level in the low-frequency band. In this analysis, the phase parameters are set to ϕp=40∘\phi_p = 40^\circ, ϕs=0∘\phi_s = 0^\circ, and ζ=−70∘\zeta= -70^\circ. By measuring the velocity (or momentum) of the torsion bars rather than their position, the speed-meter configuration effectively circumvents the SQL-imposed trade-off, resulting in broadband sensitivity improvement, particularly toward lower frequencies. While realizing 10 m-scale sapphire or silicon torsion bars presents significant technical challenges in fabrication, suspension, and cryogenic operation, the combination of torsion-bar detectors with QND speed-meter techniques offers a promising pathway to unlock performance beyond that of conventional TOBA designs. However, even if there is 1m torsion bar design, CHRONOS have enough science reaches.

The test masses are assumed to be sapphire mirrors with a diameter of 22 cm, identical to those used in KAGRA [53], and connected by hydro-catalysis bonding [54]. Cryogenic operation plays a crucial role in this design: it relaxes the mechanical QQ requirements of the bonding interface and suppresses thermal lensing without relying on extreme laser power or high finesse. These features make the implementation of QND techniques in torsion-bar detectors more feasible than in room-temperature, high-power interferometric configurations.

In the future, increasingly precise measurements from cosmic microwave background (CMB) experiments [55, 56], pulsar timing arrays [57], and next-generation interferometers [58, 59, 60] will provide probes of GW sources across a wide frequency range. In this multi-messenger landscape, CHRONOS measurements will play an important role by directly accessing the sub-Hz regime that remains challenging for other approaches.

Conclusion

We have presented the design concept of CHRONOS, a next-generation ground-based GW detector optimized for the unexplored 0.1–10 Hz band. By combining a triangular Sagnac interferometer with torsion-bar test masses, CHRONOS expects to achieves the first QND measurement of angular momentum in a macroscopic system [10, 29]. This speed-meter readout suppresses quantum radiation-pressure noise, enabling sub-Hz sensitivity. With a target sensitivity of h≃5×10−19 Hz−1/2h \simeq5 \times10^{-19}\ \mathrm{Hz}^{-1/2} at f∼2 Hzf \sim2\ \mathrm{Hz}, CHRONOS will open a new window for GW astronomy. It enables detection of intermediate-mass black hole binaries [34], probing SGWB from the early universe [43, 56], and detecting prompt gravity signals from large earthquakes [49, 50, 51]. By bridging the gap between LISA [4] and future detectors such as Voyager and the Einstein Telescope [61, 62], CHRONOS will establish a crucial platform for multi-band GW and multi-messenger astronomy.

Acknowledgments

We thank S.Takano, M.Ando and T.Namikawa for providing the TOBA data and CMB data. We also thank K.W.Ng and M.Hazumi for their academic advice during the preparation of this manuscript. We thank M.Hasegawa, T.Kanayama, S.Matsushita, H.Murakami, M.Inoue, and R.Shibuya for support to establish CHRONOS team. Y.I. and

H.W. acknowledges support from NSTC, CHiP and Academia Sinica in Taiwan under Grant No.114-2112-M-008-006-, and No.AS-TP-112-M01.

References

References

  1. [1]B. P. Abbott et al., Phys. Rev. Lett. 116, 061102 (2016).
  2. [2]F. Acernese et al. (Virgo Collaboration), Class. Quantum Grav. 32, 024001 (2015).
  3. [3]T. Akutsu et al. (KAGRA Collaboration), Prog. Theor. Exp. Phys. 2021, 05A101 (2021).
  4. [4]P. Amaro-Seoane et al., arXiv:1702.00786 (2017).
  5. [5]M. Ando et al., Physical Review Letters 105, 161101 (2010).
  6. [6]L. Ju, C. Zhao, and D. Blair, in Proceedings of the 13th Marcel Grossmann Meeting (2019) pp. 2487–2492.
  7. [7]C. M. Caves, K. S. Thorne, R. W. P. Drever, V. D. Sandberg, and M. Zimmermann, Reviews of Modern Physics 52, 341 (1980).
  8. [8]V. B. Braginsky, Y. I. Vorontsov, and K. S. Thorne, Science 209, 547 (1980).
  9. [9]V. B. Braginsky and F. Y. Khalili, Quantum Measurement (Cambridge University Press, 1996).
  10. [10]S. L. Danilishin and F. Y. Khalili, Living Rev. Relativ. 15, 5 (2012).
  11. [11]V. B. Braginsky and F. Y. Khalili, Phys. Lett. A 147, 251 (1990).
  12. [12]P. Purdue and Y. Chen, Physical Review D 66, 122004 (2002).
  13. [13]F. Y. Khalili, Physics Letters A 298, 308 (2002).
  14. [14]D. I. Robertson et al., Review of Scientific Instruments 66, 4447 (1995).
  15. [15]E. Chase, Detector Characterization of the LIGO 40 m Prototype Interferometer, Tech. Rep. LIGO-T1500123 (LIGO / Caltech / MIT, 2015).
  16. [16]M. Ando and the TAMA Collaboration, arXiv preprint arXiv:astro-ph/0105473 (2001), astro-ph/0105473.DOI
  17. [17]D. Tatsumi and the TAMA Collaboration (2008).
  18. [18]L. S. Collaboration and T. Collaboration, arXiv preprint arXiv:gr-qc/0507081 (2005), gr-qc/0507081.DOI
  19. [19]Y. Inoue et al., In preparation (2025), arXiv:2510.24780 [physics.ins-det].
  20. [20]M. Ozawa, Physical Review A 67, 042105 (2003).
  21. [21]M. Ozawa, Annals of Physics 311, 350 (2004).
  22. [22]D. D. Brown, A. Freise, et al., SoftwareX 14, 100678 (2021).
  23. [23]R. X. Adhikari, Rev. Mod. Phys. 86, 121 (2014).
  24. [24]A. Buonanno and Y. Chen, Physical Review D 64, 042006 (2001), arXiv:gr-qc/0102012.DOI
  25. [25]A. Buonanno and Y. Chen, Physical Review D 65, 042001 (2002), arXiv:gr-qc/0107021.DOI
  26. [26]Y. Chen, Physical Review D 67, 122004 (2003), arXiv:gr-qc/0208051.DOI
  27. [27]K. Yamamoto, M. Ando, K. Kawabe, et al., Physical Review A 81, 038849 (2010), arXiv:0912.2603 [quant-ph].DOI
  28. [28]P. Purdue, Phys. Rev. D 66, 10.1103/PhysRevD.66.022001 (2001), arXiv:gr-qc/0111042 [gr-qc].
  29. [29]Y. Chen, Phys. Rev. D 67, 122004 (2003).
  30. [30]S. L. Danilishin and F. Y. Khalili, Living Reviews in Relativity 15, 5 (2012).
  31. [31]C. Gräf, B. Barr, A. S. Bell, S. L. Danilishin, et al., Classical and Quantum Gravity 31, 215009 (2014), arXiv:1405.2783 [gr-qc].
  32. [32]D. Tanabe et al., In preparation (2025), arXiv:2510.24780 [physics.ins-det].
  33. [33]Y. Michimura et al., Classical and Quantum Gravity 34, 225001 (2017).
  34. [34]A. Sesana, Phys. Rev. Lett. 116, 231102 (2016).
  35. [35]M. C. Miller, Astrophys. J. 618, 426 (2004).
  36. [36]P. Amaro-Seoane, in J. Phys. Conf. Ser., Vol. 840 (2017) p. 012002.
  37. [37]N. Christensen, Rep. Prog. Phys. 82, 016903 (2019).
  38. [38]R. Abbott et al., Phys. Rev. D 104, 022004 (2021), arXiv:2101.12130 [gr-qc].DOI
  39. [39]G. Boileau, N. Christensen, and R. Meyer, Phys. Rev. D 106, 063025 (2022), arXiv:2204.03867 [gr-qc].DOI
  40. [40]G. W. Ng, Phys. Rev. D 106, 043505 (2022), arXiv:2106.12843 [astro-ph.CO].DOI
  41. [41]T. Namikawa, S. Saga, D. Yamauchi, and A. Taruya, Phys. Rev. D 100, 021303 (2019).
  42. [42]The-LIGO-Scientific-Collaboration, Physical Review D 100, 061101 (2019), arXiv:arXiv:1903.02886 [gr-qc].
  43. [43]P. Campeti, E. Komatsu, D. Poletti, and C. Baccigalupi, Journal of Cosmology and Astroparticle Physics (01), 012, arXiv:arXiv:2007.
  44. [44]K. Kohri and T. Terada, Phys. Rev. D 97, 123532 (2018), arXiv:1804.08577 [astro-ph.CO].DOI
  45. [45]G. Domènech, Universe 7, 398 (2021), arXiv:2109.01398 [gr-qc].DOI
  46. [46]X. Siemens, V. Mandic, and J. Creighton, Phys. Rev. D 73, 105001 (2006), astro-ph/0610920.
  47. [47]J. J. Blanco-Pillado and K. D. Olum, Phys. Rev. D 96, 104046 (2017).
  48. [48]P. Auclair et al., JCAP (04), 034, 1909.00819.
  49. [49]J. Harms, S. Dorsher, H. J. Paik, and M. Venkateswara, Living Reviews in Relativity 18, 10.1007/lrr-2015-3 (2015).
  50. [50]J.-P. Montagner, K. Juhel, M. Barsuglia, et al., Nat. Commun. 7, 13349 (2016).
  51. [51]M. Vallée, J.-P. Ampuero, K. Juhel, et al., Science 358, 1164 (2017).
  52. [52]Academia sinica gravitational research facility (asgraf) (2021), available at https://www.phys.sinica.edu.tw/ gravitation-physics/research.html.
  53. [53]T. Ushiba et al., Classical and Quantum Gravity 36, 105011 (2019), arXiv:1902.06645 [physics.ins-det].
  54. [54]E. J. Elliffe et al., Classical and Quantum Gravity 22, 257 (2005).
  55. [55]M. Abitbol et al. (Simons Observatory), JCAP 2025 (08), 034, arXiv:2503.00636 [astro-ph.IM].arxiv.org/abs/2503.00636
  56. [56]E. Allys et al. (LiteBIRD), PTEP 2023, 042F01 (2023), arXiv:2202.02773 [astro-ph.IM].DOI
  57. [57]P. E. Dewdney et al., Proceedings of the IEEE 97, 1482 (2009).
  58. [58]R. X. Adhikari et al., Classical and Quantum Gravity 37, 165003 (2020).
  59. [59]M. Punturo et al., Classical and Quantum Gravity 27, 194002 (2010), arXiv:1002.0461 [gr-qc].
  60. [60]M. Evans et al., arXiv e-prints (2021), arXiv:2109.09882 [gr-qc].arxiv.org/abs/2109.09882
  61. [61]LIGO-Scientific-Collaboration, LIGO Voyager Concept Study, Tech. Rep. (LIGO Laboratory, 2020).
  62. [62]M. Punturo et al., The Einstein Telescope: a third-generation gravitational wave observatory, Tech. Rep. 19 (ET Science Team, 2010).

Paper details

vlnc:W_bghn66nf
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 3

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents