WorksPhysics and Astronomy
Classical Simulation of Lossy Gaussian Boson Sampling beyond Square-Root Regime
Abstract
Photon loss makes Gaussian boson sampling easier to simulate classically. A standard approach replaces the lossy input by classical light, and it stays accurate while the mean number of surviving photons grows no faster than the square root of the number of squeezed inputs at fixed squeezing and accuracy. We prove that this scale is a limit of replacement by classical light. For explicit interferometers, no state with a nonnegative Glauber–Sudarshan representation, Gaussian or not and however correlated, keeps the error in the photon count distribution small beyond this scale. We then surpass this limit by approximating the detection instead of the input. The sampler evolves the state exactly between detections and, after each detection, replaces the conditional state by a Gaussian with the same covariance. For every interferometer its total variation error is at polynomial expected cost, where is the photon survival probability. The mean surviving photon number can therefore grow as at fixed accuracy. A separate pair construction reaches when every input mode is equally squeezed.
main.pdf
Classical Simulation of Lossy Gaussian Boson Sampling beyond Square-Root Regime
Abstract
Introduction
Gaussian boson sampling (GBS) probes interference among photons using squeezed light, passive optics, and photon-number-resolving (PNR) detection [1, 2, 3, 4], providing the basis for photonic quantum advantage experiments [5, 6, 7, 8, 9]. Photon loss is a dominant imperfection in experiments. It can also reduce the cost of classical simulation [10, 11, 12, 13, 14, 15, 16]. A claim of quantum advantage therefore has to check that the loss of the experiment lies outside the classically simulable regime. For Fock state inputs, efficient simulation is known when the surviving photon number grows more slowly than the square root of the input photon number [10, 11]. A square-root simulation regime is also known for lossy GBS at fixed squeezing and accuracy [13, 15, 16].
A nonnegative Glauber–Sudarshan representation gives an efficient PNR sampler whenever its distribution of coherent amplitudes can be sampled efficiently [17]. The classical Gaussian reference has a fidelity deficit per input relative to the GBS state. For inputs, this yields a total variation bound [13] [18]. At fixed squeezing and accuracy, this gives the sufficient regime , with a suitably small constant, and hence . However, Gaussian optimization alone does not establish whether non-Gaussian classical references can improve this exponent.
Tensor-network methods retain a nonclassical component. These methods decompose the lossy state exactly into a pure Gaussian state with reduced squeezing followed by correlated Gaussian displacement noise. The pure component is approximated by a matrix product state [16]. Under uniform loss its mean photon number is . The corresponding entanglement analysis retains the square-root leading power, with logarithmic refinements [16]. More recently, Liu et al. developed a conversion from Gaussian states to matrix product states that avoids hafnian calculations [19].
We first show that allowing non-Gaussian classical references does not remove the square-root limitation. For explicit interferometers, every state with a nonnegative Glauber–Sudarshan representation incurs a total variation error of at least in its PNR distribution, even with non-Gaussian references and arbitrary intermode correlations. Non-Gaussian classical references therefore cannot improve the square-root scaling in the worst case.
Our approach can surpass this bound by approximating the detection process rather than replacing the input by classical light (Figure 1). The initial state is unchanged, and evolution between detections is treated exactly. At low transmission, a typical detection changes the remaining light only slightly. Retaining the leading change leaves an error of order . This approximation is made only when a photon is detected, so loss supplies a second suppression. We prove a total variation error bound for the full PNR distribution, including rare records with large conditional fluctuations. The sampler has polynomial expected arithmetic cost. At fixed squeezing and accuracy, permits a mean surviving photon number of order . When every input mode is equally squeezed, a simpler construction based on pair generation and amplification reaches . The detection approximation also combines with the exact input decomposition of Ref. [16]. For the single-mode and few-mode examples studied, the combined sampler has lower empirical error than the classical Gaussian reference at parameter values motivated by experiments.
Figure 1. Classical-light replacement and detection approximation for lossy GBS. squeezed inputs and vacua pass through loss , an interferometer , and PNR detectors. (a) In classical-light replacement [13] each lossy input, squeezed below the vacuum circle (dashed), is replaced by the classical Gaussian state of maximal fidelity and the rest is exact. Theorem 1 bounds the error from below by on its interferometer family. (b) In the present method the input is exact and the detection record is processed one click at a time. After each click the non-Gaussian conditional state (red core) is replaced by the Gaussian with the same covariance at a cost of order for typical records, which gives Theorem 2.
Setup
The input consists of squeezed vacuum states with a common fixed magnitude and additional modes prepared in vacuum. The occupied columns of the passive interferometer form an isometry , . Squeezing phases are absorbed into its columns. Uniform pure loss of survival probability commutes with passive interference [20]. Write
The target is the full distribution on , and . The vacuum input modes are present before loss, and modes emptied by loss remain part of the squeezed inputs. Constants in the asymptotic bounds may depend on the fixed squeezing .
Square-root barrier for classical light.— Let
be the classical states of modes [21], the mixtures of products of coherent states . The measure may be singular, non-Gaussian, and correlated across all modes, and it may depend on the target. Write for the PNR distribution of , the mixture under of products of Poisson distributions with intensities .
Theorem 1 (Lower bound on classical replacement). For every fixed , even , and , there is a passive isometry such that
for . On this family the optimal error within is .
Proof sketch. sends inputs and , , through the beam splitter
which turns two equally squeezed vacua into a two-mode squeezed vacuum, and leaves the other outputs in vacuum. Let be the probability that the two outputs of one pair record and photons under , and the same probability for a product coherent state with intensities and . The counts of the coherent state are independent Poisson variables, so
a constraint on classical count probabilities [22, 23]. Every inherits it by mixing. The lossy pair violates it, as shown in the Supplemental Material (SM) [24],
at order and without any unbounded moment. To add up the pairs, let , , and otherwise, and let with . At a fixed coherent amplitude of all modes the pair counts are independent, so Eq. (4) gives for every , whatever its correlations across pairs. Under the pairs are independent, and minimizing over gives with . The Cauchy–Schwarz inequality
and then give
The product of thermal states with the marginals of is classical and gives the matching upper bound derived in the SM.
Theorem 1 is a statement about a method, not about the hardness of a distribution. Every algorithm that replaces the input by classical light and then detects produces some with . On this family, every has a photon count error of at least . For fixed error below one this forces , hence . The square-root regime is therefore the best that classical-light replacement can reach in the worst case, whether the reference is Gaussian as in Ref. [13] or non-Gaussian and correlated across modes. The theorem does not cover references that are Gaussian but nonclassical, or the nonclassical core retained in Ref. [16], and it is not a complexity lower bound.
Beyond the barrier by approximating the detection.—The pair family itself is easy to sample, as a product of two-mode distributions, and Theorem 2 below samples it as a special case. The limitation is a property of the approximation class and not a lower bound on classical computation, so a method that keeps the input and approximates the detection is not bound by it.
Theorem 2 (Classical sampling beyond the square-root barrier). For every fixed , , and passive isometry , there is a randomized classical algorithm with polynomial expected arithmetic cost whose output distribution satisfies
where is independent of . Thus , for a sufficiently small fixed , permits at fixed accuracy.
The theorem applies to the squeezed and vacuum inputs specified above, with no restriction on depth or connectivity, and output collisions are included.
Proof sketch. The construction rewrites PNR detection as a fictitious absorption process. Couple every output mode to a perfect absorber that removes photons one at a time and records the mode of each removal. Run the process until every photon is absorbed. The number of removals recorded in mode is then its photon number, so the record has exactly the PNR distribution of the state. The fictitious time only orders the clicks and is integrated out. Along the process the conditional state follows two rules. While no click occurs it is damped by , with the total photon number operator, which is the state conditioned on no photon having been removed yet. At a click in mode it becomes , a photon subtraction, with the rate of that mode. Neither rule is a unitary operation, and nothing is applied in the experiment.
For a Gaussian state, the evolution between detections and the covariance change caused by a click have closed expressions. Use vacuum covariance , write , and set , , and . If is the realification of , the state after loss and interference has
The no-click damping keeps a Gaussian state Gaussian, and a photon subtraction changes its covariance by a known amount. For the projector onto output ’s two quadratures,
The waiting time to the next click also has a closed form. The probability of no click during the next interval of duration is
and its limit , the vacuum probability of the current state, is the probability that no photon is left.
The sampler, whose output distribution we denote by , therefore stores only . Starting from , it draws from (10) whether the record has ended and otherwise the time of the next click. It chooses the clicked output in proportion to the rates and applies (9). The clicks per output form the sample. The no-click step is exact. The single approximation is that after a click the exact state, which is no longer Gaussian, is replaced by the centered Gaussian whose covariance is . Gaussian trajectories and photon subtraction formulas are established tools [?, ?]. We bound the accumulated error in the full PNR distribution for every interferometer, including rare detection records. No hafnian is needed, photon number and covariance are not capped, and the expected number of clicks is at most . With stored through a matrix , a direct implementation has expected cost and memory , with scalar inversion of counted as a primitive, as derived in the SM.
The click rate and the error of one reset suggest the cubic scale. At low transmission each output holds photons. A subtraction therefore changes the state by , and along typical records the replacement by a Gaussian costs per click. Clicks occur at a total rate of order , and the product is . The following bound also includes rare records with large covariance changes.
Let , with rank , and define a shift used only in the proof
No noise is added to the sampler, and an exact vacuum direction contributes zero to . An estimate of the relative jump size gives, along every candidate trajectory,
These inequalities use the paired quadrature structure of squeezed inputs, not a lower bound on any output’s occupation.
Let be the trace distance between the exact state after a click and its Gaussian replacement. The local estimate based on Gaussian displacements implies
.
Let be the generator of the process, so that is the expected rate of change of . It is the derivative along the no-click flow, including the time derivative of the shift, plus the jump terms . It obeys
The linear jump terms cancel the nonlinear drift between detections by Eq. (12), and noncommuting jumps are included.
Choose and let be the first time . Before that time the drift is negative, and at a crossing . Consequently,
Compare the target with a hybrid that uses the trajectory approximation up to and exact readout afterward. Its error before the crossing is bounded by Eq. (13), and its distance from the actual, unstopped sampler is at most the crossing probability. Thus
with the explicit initial budget
For , gives an explicit constant in the SM. Taking extends the bound to all , trivially when . The case is exact. The factor rather than comes from the occupied covariance subspace. Equation (15) controls large conditional fluctuations with the same budget as ordinary trajectories, so no assumption about typical records is needed.
Together, the two theorems give a direct separation on the same target family. Choose with . Then while , so every classical-light count distribution becomes asymptotically maximally distant from the target, whereas the classical sampling error vanishes. Photon counting statistics that cannot be approximated by classical light in this regime can nevertheless be approximated efficiently on a classical computer. The separation is proved on the pair family of Theorem 1. For other interferometers classical light
may remain accurate in this regime, and Theorem 1 only shows that no classical-light method is accurate on every interferometer, whereas Theorem 2 holds for all of them.
Accuracy at experimental squeezing.—For the numerical examples below, we combine the detection approximation with the exact input decomposition of Ref. [16]. Each lossy squeezed input is exactly a pure Gaussian core of reduced squeezing followed by classical Gaussian displacement noise. The combined sampler draws this noise and propagates it through as a displacement. It then uses the same detection construction on the displaced pure core, matching mean and covariance at each reset. The cost is unchanged, and the update with a mean is given in the SM. Figure 2 compares errors on one squeezed input, where the target probabilities can be computed directly. At the empirical error of the combined sampler is below that of the classical reference by a factor between five and twenty across the transmissions. At the factor is roughly three to five across the squeezing values. Its mean count agrees with the exact value within statistical uncertainty, and random three-mode interferometers give the same ordering. In the examples reported in the SM, is more accurate than the reference for and less accurate at larger squeezing. The improvement is observed numerically. No uniform analytic error bound is proved for . For the centered reset of Theorem 2 the cubic order is attained by an explicit family of inputs, as shown in the SM.
Figure 2. Error for one lossy squeezed input (). Total variation distance between the exact photon count distribution and the distributions of classical-light replacement by the classical Gaussian state of maximal fidelity [13] and of the combined sampler, (a) against the transmission at and (b) against the squeezing at , close to the reported overall efficiency of 0.51 [9]. The reference distance is computed without Monte Carlo sampling. The sampler values are empirical distances from to records. The SM gives pointwise 95% statistical upper bounds, including the tail correction.
All input modes squeezed.—When , we use an exact amplifier decomposition for the equally squeezed inputs. The isometry is now a unitary . Put
The target is a pure squeezed core of matrix followed by identical quantum-limited amplifiers of gain [27]. The amplifiers commute with , which makes their count kernels local at the output, and they represent the target rather than hardware added to it. The simplest sampler draws the exact number of core pairs from a negative binomial distribution, denoting the distribution with probabilities for and mean ,
assigns the pair endpoints independently, records their counts , adds independent , and returns . No hafnian, rejection score, or trajectory is needed, and the approximation is solely in the interference between distinct pairs, so the distribution of the total output photon number is exact. With ,
Amplifier smoothing bounds the omitted cycles, including their phase dependence, as shown in the SM. (20) gives the stronger exponent for the mean surviving photon number, but its error is , instead of . The condition is needed because the same amplifier would create photons in additional vacuum input modes.
Discussion.—Claims of quantum advantage in lossy GBS must rule out simulation within the known efficient regimes. Classical-light replacement [13] and the entanglement analysis of Ref. [16] give sufficient regimes with the same leading power. Theorem 1 establishes a limit for classical replacement, not for tensor-network methods or classical computation in general. Theorem 2 extends the efficient regime to surviving photons for every interferometer, and the pair construction extends it to when every input is equally squeezed.
Theorem 2 gives a nontrivial asymptotic bound when with bounded. It does not provide a nontrivial uniform bound at fixed nonzero transmission. This is consistent with the hardness arguments for ideal GBS [3] [28]. Hardness of evaluating noisy output probabilities [29] concerns a different task from sampling within a fixed total variation error. The latest experiment, with 1,024 squeezed inputs at an overall transmission near 0.5, has , where Theorem 2 gives only the trivial bound of one [9].
Several questions remain open. Whether typical interferometers also defeat classical light beyond the square-root scale would turn Theorem 1 into an average-case statement. Whether or is the true limit of polynomial simulation is tied to hardness assumptions, and whether a reset rule with polynomial cost can pass the cubic order of the centered rule is open. Existing approximation algorithms for lossy Fock inputs also give a square-root scaling regime [10, 11]. The trajectory used here relies on the Gaussian closure of the conditional state, so a detection approximation for lossy Fock states would need a different conditional description, and whether one exists with controlled error is open.
The main theoretical results were developed by the author. GPT-6 and Fable-5.1 were used under the author’s direction to assist with exploring and refining mathematical arguments, checking calculations, numerical simulations, and revising the manuscript. The author independently verified the final proofs and takes full responsibility for the results and conclusions. This work was supported by the Institute of Information & Communications Technology Planning & Evaluation (IITP) grant funded by the Korean government (Ministry of Science and ICT (MSIT)) (No. RS-2024-00437284, No. RS-2025-02283189), and National Research Foundation of Korea (NRF) grant funded by the Korean government (MSIT) (No. RS-2024-00431768).
References
Supplemental Material for “Classical Simulation of Lossy Gaussian Boson Sampling beyond Square-Root Regime”
Youngrong Lim
Sections SI and SII give the proofs of Theorems 1 and 2. Section SIII treats nonuniform inputs and the limits of the centered reset. Section SIV gives the pair construction for equally squeezed inputs. The separate variant with displacement noise and its numerical evaluation are described in Secs. SV and SVI.
We use vacuum covariance and write and . Quadratures are ordered as , with commutator matrix [1]. Except in Sec. SIII A, the squeezed inputs have common magnitude and survival probability . The other inputs are vacuum. Put
Then , , and . Constants in asymptotic bounds may depend on the fixed .
supplement.pdf
Supplemental Material for ``Classical Simulation of Lossy Gaussian Boson Sampling beyond Square-Root Regime''
Proof of Theorem 1
We use the notation , , and of the main text. The reference measure may be singular, non-Gaussian, and correlated across all modes, with no energy bound [2].
Two output modes
The construction uses independent pairs of squeezed inputs. For , apply to each input pair. Since , the target is a product of attenuated two-mode squeezed states. One pair has generating function
Write and . Then . For a coherent state with intensities , . Every positive mixture preserves this inequality between count probabilities [3, 4].
Combining the pairs
Set , , and otherwise. For , let and . At a fixed coherent amplitude of all modes, the counts are independent and on each pair. Averaging over the amplitude therefore gives for every classical reference, even when its pairs are correlated. Under the target distribution the pairs are independent. Choosing
gives . {#eq:S2}
For , weighted Cauchy–Schwarz now yields
The endpoint follows by continuity. With ,
The inequality uses and the decrease of the bracket on . Hence
Appended vacuum outputs can be marginalized; the remaining marginal of a classical state is still classical. For odd , ignoring one squeezed input gives the same statement with replaced by .
For the matching upper bound on this family, use the product of the two thermal marginals in each pair. Two bivariate distributions with identical marginals have TV at most twice the sum of their probabilities of both counts being nonzero. These probabilities are bounded by and . Summing over pairs gives and establishes the claimed quadratic scale.
Proof of Theorem 2
We first specify the centered sampler . We then bound the error of each Gaussian replacement and sum it over the complete detection record. The expected arithmetic cost is given at the end of the section.
Conditional evolution and sampling
Let be the realification of and the projector onto the occupied covariance subspace. Then
The projector has rank and commutes with . Let select the two quadratures of physical output , and . Thus . All covariances below are supported perturbations of vacuum, , with .
PNR readout can be represented by complete monitored absorption, with one jump for each photon detected in output . While no click occurs, a Gaussian state remains Gaussian and obeys
Here is the probability of no click during the next interval of length . At a click in ,
The covariance after photon subtraction is exact [5]. The Gaussian reset replaces only the higher cumulants by their Gaussian values, as in Gaussian trajectory approximations [6]. Since , the new covariance is physical. A detector with zero rate is never selected.
At each step the record ends with probability . Otherwise draw uniformly from and solve . Evolve with , select the detector in proportion to its rate at that time, and apply the reset. Repeating these steps gives the count in each output. No count or covariance cutoff is imposed.
For numerical implementation, put and . Then on the finite interval .
Covariance change after a detection
The covariance increment need not be small along every record. We control it relative to a positive shift of . For , put
The shift is used only in the proof and does not change the sampler. The flow is operator monotone on the physical domain, and every reset adds a positive matrix. Hence . Put , , and
The eigenvalues of are and on the two occupied real eigenspaces. The trace of on either eigenspace is . This follows from the realification of and is the point where the optical structure is used.
Writing and , direct substitution gives
Consequently , , and . The last relation is valid because and commute on the occupied subspace. Restricting inverses to that subspace,
The baseline resolvent bound implies
The function is increasing and , so . Dividing by the rate gives . Since , its norm is bounded by its trace, giving . Finally, summing over the detector label uses . We have therefore obtained
All inverses act on . No positive lower bound on an output occupation is needed, and the estimate does not depend on the number of vacuum inputs.
Error of one Gaussian replacement
For a centered Gaussian with covariance , define the displacement generator by . Photon subtraction and the Gaussian with the same covariance satisfy
Take a Gaussian purification with covariance , which satisfies . For a system displacement , choose the ancillary generator that minimizes the variance of the combined quadrature . The variance is and the system displacement is unchanged. Ancillary commutators vanish after the partial trace. Taylor’s integral remainder and contraction of the trace norm give
The second identity follows from Wick’s rule for commuting displacement commutators.
A Gaussian unitary takes a pure Gaussian state to vacuum. For a centered quadrature of variance , the fourth commutator divided by therefore reduces to the two blocks
If is the unique negative root of , their total trace norm is . Using in Eq. (34) gives
The intermediate derivatives can be defined with finite Fock projections. The displayed Gaussian moments allow these projections to be removed. The resulting constant is independent of the number of modes.
To sum the local costs, use the fact that , , commute on . Combining Eqs. (32) and (33) gives
To see this, apply with and . Then use and sum over the detector label.
Termination and total error
The energy satisfies . Localization shows that is a nonnegative local martingale and hence a supermartingale. Since , the total number of clicks obeys
Thus the process is nonexplosive and terminates almost surely. The supermartingale argument proves an upper bound on the mean, not equality.
To compare the output distributions, first fix a finite time and a finite click cap. Retain one outcome for an unfinished record. Consider hybrids that follow the candidate for the first clicks and use exact physical readout afterward. Two adjacent hybrids share the candidate prefix and the probabilities of the next click. They differ only at that click, where is replaced by .
Every event of the exact suffix is represented by an effect . Its probability changes by at most . Summing over adjacent hybrids weights this error by the candidate prefix probabilities. The compensator of the counting process turns the sum over clicks into a time integral. Equation (S19) and monotone convergence remove the two analytical caps. Thus
The same comparison holds when the switch to exact readout occurs at a stopping time of the candidate process. Forgetting the auxiliary click times cannot increase TV, so the bound applies to the PNR record. The algorithm imposes neither analytical cap.
Cubic error bound
The accumulated error is controlled by one positive covariance quantity. Set and
Positivity follows from and . A vacuum direction contributes zero. The exact generator, including , is
The deterministic contribution cancels the part of the jumps linear in by Eq. (S13). No commutation of and an individual jump is required.
For ,
To prove the first relation, write , , in a eigenbasis. Symmetrize the terms , use , and then . Trace against for the second relation. Thus
To include rare records with large covariance changes, choose , set , and let . This stopping time is used only in the proof. Dynkin’s formula for the stopped process and nonnegativity give
At a crossing, has an eigenvalue and , so . Between jumps decreases; at a crossing jump . This bounds overshoots and justifies stopped localization. If , the resulting bound is trivial.
The distance from the target to the stopped hybrid is at most . The hybrid and the original sampler agree until . Their distance is therefore bounded by the crossing probability. Equation (S25) bounds the sum of these contributions, giving
The sampler does not compute the exact suffix used in this comparison. The initial value is
Taking , , , and yields the explicit choice
for . Define . For , the right side of the theorem is one. At the sampler returns vacuum exactly.
The fixed threshold requires . An admissible exists whenever . The smaller interval above is used to obtain the explicit coefficient in Eq. (47).
Arithmetic cost
Store the realification and the supported covariance matrix , where . For detector , let contain rows and of and put . Each has rank at most two and . The exact reduced updates are
Sylvester’s determinant identity reduces the no-click determinant to dimensions. Hence added vacuum modes do not increase the size of the dynamical covariance matrix.
A conservative implementation diagonalizes before each waiting-time draw at cost and rotates the stored detector rows at cost . Each survival evaluation then costs , and rates at the chosen time cost . The rank-two reset costs . Including the terminal draw, there are steps, with . If bounds the number of scalar survival evaluations per inversion, the expected work is
Equation (S30) counts scalar inversion as an arithmetic primitive. It is an operation count, not a bit complexity bound or a runtime measurement. If a numerical implementation satisfies , its total error is at most the optical bound plus , including rounding errors.
Extensions and limits of the centered reset
Nonuniform squeezing and loss
The same scalar shift gives a conservative extension to source dependent parameters. Let source have squeezing and survival probability , and define
For , use . The baseline eigenvalues in Sec. SIIB become and . Each corresponding real eigendirection has detector weight . The resolvent estimate becomes
For each nonvacuum source, . In addition,
Since , . Zero sources follow by continuity. Thus Eq. (32) still holds. The initial budget is
For , the proof of Sec. SII E gives
The same trivial extension uses outside this interval. The scalar shift gives , rather than .
Additional output loss. Attenuation of output with transmission is implemented after sampling by . This is exactly loss followed by PNR readout, and the common thinning kernel contracts TV. The bound based on input loss is unchanged; this argument does not sharpen it using the additional output losses.
Cubic error of the centered reset
The cubic order in Theorem 2 is attained by its centered reset rule. For , the modes factorize. Write for the exact count law of one mode and for the centered sampler. Their probabilities of three counts obey
At leading order, one reset maps and . Hence
The factor comes from the three ordered detection times. Direct substitution yields
Coarse graining to the binary event of exactly three counts gives an affinity deficit . Products over the independent modes then imply
for sufficiently small and some $\widetilde c_r>0.
Local obstruction for centered Gaussian mixtures
Let be centered Gaussian with covariance , and let be the increment of Sec. SII C. The exact conditional characteristic function is
Consider a positive mixture of centered Gaussians with . Set and . Convexity gives . The Weyl operator is unitary, so
The lower bound is of second order in and concerns one conditional state. It does not cover mixtures with displacements or, by itself, imply a bound on the final PNR error of another adaptive algorithm.
Pair construction when all inputs are equally squeezed
Here and every input has the same squeezing and loss. The common amplifier representation gives a second sampling method, based on independently placed pairs rather than Gaussian resets.
Amplifier representation
Set , ,
The exact covariance identities
express the target as a pure Gaussian core of squeezing matrix followed by identical quantum-limited amplifiers. Equal gains commute with passive interference. The corresponding output count kernel follows from the amplifier Kraus operators [7]
For the output is vacuum. For , and the amplifier is the identity. Assigning a nontrivial amplifier to an additional vacuum input would change the target.
Sampling and total photon number
Draw with
Choose independent ordered pairs with probability . Accumulate their endpoints in and sample from Eq. (59). Denote the output law by . For real shape , the negative binomial convention is , with mean .
Computing and the row sampling tables costs arithmetic and storage. Each sample then costs , where .
The exact core pair number is Eq. (60), obtained by summing squeezed-vacuum pair counts of shape [8, 9]. Conditional on , total amplifier offspring is independent of the endpoint positions. Consequently target and candidate have the same generating function for the total count
The distribution of the total count is therefore exact, although the spatial distribution need not be. For , the spatial law is also exact. This gives the finite parameter bound
Amplifier smoothing
To bound the omitted interference, we compare with a Poisson distribution of independent pairs. For a diagonal formal variable , put . This is distinct from the shifted covariance . The exact core and an auxiliary Poisson pair proposal have generating functions
The cycles retain the complex phases of [10]. The Poisson proposal is used only for the error comparison. The sampler itself uses the exact pair number.
Write for Eq. (59), , and for the law of photons with their geometric offspring, so . Let denote the signed coefficient sequence of . The exact amplified law is , where . Convolution contracts the signed norm.
The amplifier kernel gives an estimate on the resulting count probabilities. For one mode with , define
Factorial moments of the negative-binomial offspring give
At this is the circle inner product of and . Tensorization and Parseval therefore yield, for a finite signed polynomial ,
where denotes the normalized torus norm.
To estimate the cycle terms, set
For an analytic on the closed unit polydisc, coefficient orthogonality gives
The right side weights each nonconstant coefficient by . Symmetry and unitarity of imply
The second relation uses diagonal-to-Frobenius and Schatten Hölder inequalities, and integrating the radial expansion gives
It remains to control products of the cycle terms. Use shifted variables , so , and define
Then , each is analytic in , and . Integrating along the radius gives . For a subharmonic test function, apply the harmonic majorant first in the last coordinate, then in the preceding coordinates. This compares with a sum of independent uniform circle increments of radius . Rotation symmetry and the multinomial expansion give . Applying the comparison to and gives
A slightly larger polydisc with provides absolute convergence, so the identities for finite polynomials pass to the infinite residual.
Error bound and surviving photon number
Isolate before applying Eq. (71). The amplified Poisson pair proposal then has error at most
The exact negative-binomial pair number is the compound Poisson variable , where independently. Coupling it to gives
The endpoint and amplifier kernels are the same in this comparison. The full TV distance for is therefore bounded by the minimum of one, the right side of Eq. (62), and .
Let and . Exact parameter identities imply
The rational estimates , , and give
Since and ,
For fixed and accuracy, take proportional to . The mean surviving count is then proportional to . At , both distributions are vacuum.
The error is , not . No rejection score is required by this construction.
Exact sampling of a few pair sectors
Fix a small . For , repeat row and column of exactly times to form , . Exact and independent-pair conditional laws are
The perfect matchings give by Cauchy–Schwarz. Accept a proposed endpoint vector with probability
A zero denominator has zero proposal probability. Keep fixed while retrying the endpoints. Other exact GBS methods can be used [11, 12], but the largest hafnian has size .
For return the independent-pair endpoint draw; do not discard the sample. Apply Eq. (59) in either case. Then
The entire amplifier tail and the exact total count distribution are retained. Fixed gives polynomial expected cost. For example, , , , and give a tail below with fewer than 41 expected endpoint proposals. This bound from finitely many exact sectors does not establish the exponent, because the core pair number grows with in that regime.
A variant with displacement noise
Combining the exact displacement decomposition of Ref. [13] with Gaussian resets gives the sampler . It retains the sampled displacement and matches both mean and covariance after each click. Theorem 2 applies to , not to this variant.
Input decomposition
A lossy squeezed input with quadrature variances is the mixture
where is the squeezed vacuum with squeezing and displaces the antisqueezed quadrature by . The noise variance is nonnegative because . The core carries the whole deficit of the squeezed variance, so is the quantity in the fidelity bound of Ref. [14] and the noise is one dimensional. For inputs the displacements are independent, and after the interferometer the state is the pure Gaussian core with covariance
displaced by . Since for small , the core occupation of an output is , while its displacement carries photons.
The refined sampler draws , forms , and runs the monitored absorption of Sec. SII on a Gaussian state that now carries a mean. Between clicks the state remains Gaussian. After a click on output the conditional state is replaced by the Gaussian with the same mean and the same covariance.
Conditional moments
Let be Gaussian with mean and covariance . Let annihilate output and let select its two quadratures. Applying Wick’s theorem to and gives
At this is the update rule of the main text, and a coherent state () is left unchanged. The no-click evolution of duration with is
Here decreases from one to the vacuum probability. The mean remains in , so store and . The expected arithmetic work has the same polynomial scaling as Eq. (49). The energy has generator , proving an upper bound on the expected count, not equality. The negative term in Eq. (83) prevents direct use of the relative jump bound and cubic budget of Sec. SII.
Small displacements
A small pure core does not make every reset small. If the displacement intensity is comparable to or smaller than the core occupation , the reset can have order one error. At zero displacement it replaces by a squeezed thermal state, at trace distance . For one mode, the case of Figure 2 of the main text, the noise of Eq. (81) is one dimensional. In the initial displacement ensemble this region has probability of order , and the detection rate there is of order . These initial rates suggest a contribution of order but do not bound the full trajectory error. The numerical improvement in Figure 2 does not sharpen the constant in Theorem 2. A core with squeezing and noise in both quadratures with variances and may remove this restriction to one noise quadrature, but no error analysis of that variant is given here.
SVI Numerical evaluation
A Probability evaluation
Figure 2 of the main text concerns . The numerical calculations use a Fock basis with cutoff 80 for the target and classical Gaussian reference. Both samplers use the covariance representation. Each point uses independent records, except at and at for .
Define the count bins as and a separate bin for . Let , be the exact target and candidate laws on these bins, and let be the empirical histogram. Write . Folding the tail is not the same as truncating and renormalizing a state. The statistical bounds below treat as exact; a numerical error in its evaluation must be added separately.
B Statistical uncertainty
For the binned laws, convexity gives . Replacing one independent record changes by at most . McDiarmid’s inequality [15] therefore yields the pointwise statement
Combining the tail into one bin gives
Thus the full count distributions satisfy, pointwise at confidence ,
The corrections are below 0.0025, 0.0032, and 0.0046 for the three sample sizes above. At and , the target tail is below , and it is below at the other points. The confidence bounds apply to each point separately. The improvement factors quoted in the main text use the empirical distances, not these confidence bounds.
If is evaluated approximately as , add to Eq. (87), together with any error in the target tail bound. A Fock cutoff alone does not bound this numerical error.
C One and three mode examples
At , becomes less accurate than the classical reference above in these tests. Over the squeezing values tested, the empirical error of is between about 0.003 and 0.013. Its sampled mean agrees with the exact mean within statistical uncertainty. This agreement does not establish exact mean preservation.
For random interferometers on three modes at , the empirical errors of the reference, , , and are (0.058, 0.058, 0.014, 0.015) at , and (0.062, 0.136, 0.04, 0.080) at $r=1.5. For , both empirical distances are comparable to sampling noise and do not resolve the true error. These tests on a few modes do not establish a uniform error bound or compare runtime with tensor network methods [13, 16].
D Checks of the formulas and implementation
The reduced covariance representation, summed jump identity, cubic generator, and local cost inequality were checked in exact rational arithmetic for 18 Gaussian prefixes and 54 detector jumps. The complex rational isometries have , and 42 jumps are noncommuting. In 18 single-mode Fock calculations, increasing the dimension from 40 to 56 changes the local trace distance by at most . The largest ratio to Eq. (33) is 0.867.
For the displaced variant, Eqs. (83) and (84) agree with the Fock calculations to in one mode and to approximately at cutoff 11 in two modes. A trajectory with nonuniform parameters and reaches without leaving .
Tests of the complete sampler use one or two squeezed inputs in up to three modes, , and . With records, the empirical distances range from the sampling resolution, about , to . Where the bound in Eq. (45) is below one, it exceeds the empirical distance by more than an order of magnitude.
For one mode at and , a run with records has mean , compared with the exact . It gives probability for more than 16 clicks, compared with for the target. The smaller sampled mean is consistent with Eq. (38), which gives only an upper bound. These numerical values do not establish failure of uniform integrability. At , numerical quadrature gives and as , consistent with the order proved for this reset in Sec. SIII B.
These calculations check the formulas at finite Fock dimension and numerical precision. They do not rigorously bound truncation or rounding errors. The analytical bounds are proved independently of the numerical tests.
References
References
- [1]C. Weedbrook, S. Pirandola, R. García-Patrón, N. J. Cerf, T. C. Ralph, J. H. Shapiro, and S. Lloyd, Gaussian quantum information, Rev. Mod. Phys. 84, 621 (2012).DOI
- [2]B. Yadin, F. C. Binder, J. Thompson, V. Narasimhachar, M. Gu, and M. S. Kim, Operational resource theory of continuous-variable nonclassicality, Phys. Rev. X 8, 041038 (2018).DOI
- [3]C. T. Lee, Nonclassical photon statistics of two-mode squeezed states, Phys. Rev. A 42, 1608 (1990).pubmed.ncbi.nlm.nih.gov/9904194
- [4]C. M. Caves, C. Zhu, G. J. Milburn, and W. Schleich, Photon statistics of two-mode squeezed states and interference in four-dimensional phase space, Phys. Rev. A 43, 3854 (1991).pubmed.ncbi.nlm.nih.gov/9905474
- [5]M. Walschaers, C. Fabre, V. Parigi, and N. Treps, Entanglement and Wigner function negativity of multimode Non-Gaussian states, Phys. Rev. Lett. 119, 183601 (2017).DOI
- [6]W. Verstraelen and M. Wouters, Gaussian Quantum trajectories for the variational simulation of open Quantum-optical systems, Appl. Sci. 8, 1427 (2018).DOI
- [7]J. S. Ivan, K. K. Sabapathy, and R. Simon, Operator-sum representation for bosonic Gaussian channels, Phys. Rev. A 84, 042311 (2011).DOI
- [8]C. S. Hamilton, R. Kruse, L. Sansoni, S. Barkhofen, C. Silberhorn, and I. Jex, Gaussian Boson sampling, Phys. Rev. Lett. 119, 170501 (2017).
- [9]R. Kruse, C. S. Hamilton, L. Sansoni, S. Barkhofen, C. Silberhorn, and I. Jex, Detailed study of Gaussian boson sampling, Phys. Rev. A 100, 032326 (2019).DOI
- [10]Y. Cardin and N. Quesada, Photon-number moments and cumulants of Gaussian states, Quantum 8, 1521 (2024).DOI
- [11]N. Quesada and J. M. Arrazola, Exact simulation of Gaussian boson sampling in polynomial space and exponential time, Phys. Rev. Research 2, 023005 (2020).DOI
- [12]N. Quesada, R. S. Chadwick, B. A. Bell, J. M. Arrazola, T. Vincent, H. Qi, and R. García-Patrón, Quadratic speed-up for simulating Gaussian boson sampling, PRX Quantum 3, 010306 (2022).DOI
- [13]C. Oh, M. Liu, Y. Alexeev, B. Fefferman, and L. Jiang, Classical algorithm for simulating experimental Gaussian boson sampling, Nat. Phys. 20, 1461 (2024).DOI
- [14]H. Qi, D. J. Brod, N. Quesada, and R. García-Patrón, Regimes of classical simulability for noisy Gaussian Boson sampling, Phys. Rev. Lett. 124, 100502 (2020).DOI
- [15]C. McDiarmid, On the method of bounded differences, in Surveys in Combinatorics, 1989, London Mathematical Society Lecture Note Series, Vol. 141 (Cambridge University Press, 1989) pp. 148–188.DOI
- [16]T. Liu, H.-K. Jin, T. Xiang, and H.-H. Tu, Efficient simulation of low-entanglement bosonic Gaussian states in polynomial time, npj Quantum Inf. 12, 110 (2026).DOI