betaFeedback

WorksComputer Science

TriSegAgent: Context-Efficient 3D Annotation with MLLMs via Tri-Planes

Abstract

Interactive segmentation models turn a few clicks into a segmentation prediction across domains, so annotators only decide where the prediction still needs correction. Annotation thus becomes a loop of inspecting the prediction and clicking again. Each step of this loop is a visual judgment, which suits general-purpose multimodal large language model (MLLM) agents. In this work, we focus on letting these agents run this loop on 3D volumes. However, the MLLM in such an agent takes only 2D images as input, so the agent must observe the 3D volume in 2D. Since the loop calls the MLLM many times, this observation must be token-compact enough to keep every call cheap, yet informative enough to show error regions in the 3D prediction. We meet both needs with tri-planes, the three orthogonal planes that cross at one point in the volume. We show, both theoretically and empirically, that tri-planes are context-efficient yet keep sufficient detail to show error regions in the 3D prediction. Building on tri-planes, we introduce TriSegAgent, an MLLM agent that refines the 3D prediction iteratively. Within the agent, the MLLM only judges the prediction on tri-planes, while a visual harness turns each judgment into a 3D action in code. To make the loop reliable, the harness places each click at an exact voxel in the volume and checks whether to accept the 3D prediction. To evaluate the agent, we build a diverse benchmark of 690 regions of interest (ROIs) from 35 public medical datasets across three imaging modalities. With frontier MLLMs, TriSegAgent reaches an overall Dice about 10 points above the strongest baseline, and its lead is even larger on targets below 3 cm. With flash-level MLLMs, it outperforms a recent 3D segmentation agent built on a frontier MLLM.

Introduction

Interactive segmentation tools, which turn a few clicks or boxes into a segmentation prediction, have been widely used for annotation across domains, from natural images [54, 99] and microscopy [9] to 3D medical volumes [24, 47, 75]. Since these tools draw most of the prediction, annotators only decide where it still needs correction [77]. Annotation thus becomes a loop of inspecting the prediction and clicking again [82]. On a 3D volume (Figure 1, middle-top), guided by prior knowledge of where the target lies, an expert browses orthogonal planes of the volume, places clicks on one plane, lets the model segment, and inspects the result in different planes until the prediction is satisfactory [47, 75]. Each decision in this loop needs only a local judgment with a clear criterion: whether the prediction covers the target in the current view. This perception–decision loop maps naturally to a multimodal large language model (MLLM) agent that looks at an image, acts through tools, and judges the outcome [43, 118]. The planes displayed are the agent’s observations; the clicks are its tool calls; and the prediction overlaid on the image is the feedback for its next decision. This work therefore focuses on enabling general-purpose MLLM agents to annotate 3D volumes through such an interactive loop. Given a volume and a text goal, the agent works with an interactive segmentation model over many steps and then returns a 3D prediction (Figure 1).

Figure 1. An MLLM agent annotates a 3D volume in an interactive loop. Middle-Top: an expert annotates the target with an interactive segmentation model in a loop of browsing views, placing clicks, segmenting, and inspecting, from the input (left) to a satisfactory prediction (right). Middle-Bottom: in TriSegAgent, an MLLM agent runs a similar loop with the same model: it looks at tri-planes, chooses clicks, and verifies the 3D prediction in several views before accepting it.

Running this loop on 3D volumes, however, exposes a gap between the data and the agent: the data are 3D voxel grids, whereas general-purpose MLLM agents take only 2D images as input. In 2D, one image with the prediction overlaid makes each decision fully observable at little token cost [68, 127]. Existing methods bridge this gap in three ways, none of which suits a long agent loop. The first trains a native 3D model [11, 111] at a high cost. Since 3D training data are limited, such a model transfers poorly to unseen settings. The second feeds a general-purpose MLLM the whole volume as a sequence of slices, like the frames of a video [13, 23, 37]. Each call then carries hundreds of images, although the current decision needs only a few of them. Such long inputs make the token cost explode over the many calls of the loop and lower the accuracy of each call [42, 57, 104]. The third shows only a few slices or projections at a time [19, 106], which keeps each call affordable but leaves the agent blind to error regions elsewhere. The latter two ways expose a fundamental dilemma between a limited context budget and spatial observability, and the key challenge is to design an observation that is token-compact yet informative enough to show error regions in the 3D prediction.

We address this challenge with synchronized tri-planes, three orthogonal planes that cross at one point (Figure 2c). Inspired by how engineering drawings [46], medical image viewers [31, 120], and connectomics tools [18] display or show 3D data, we make tri-planes the observation of the agent, since they are extremely context efficient yet keep sufficient detail. To show the 3D context around the crossing point in the same detail, a slice stack needs every slice, whereas tri-planes need only three images: for a 5133513^{3} volume, Qwen2.5-VL [13] uses about 1k tokens for one set of tri-planes, two orders of magnitude fewer than the 166k of the full slice stack. Every MLLM call is therefore cheap, and the whole annotation loop remains affordable. Tri-planes also keep sufficient detail: with the pixels of only three images, they cut the volume along all three axes, so an error region that slips between sparse parallel slices is still likely to cross one of the planes. We prove that this advantage holds in the worst case, so a few sets of tri-planes are likely to show the error regions in a 3D prediction.

Figure 2. Visualization of different 3D inputs. At the same detail, a dense slice stack costs one image per slice (DD slices in the volume), whereas tri-planes need only three images; at the same pixel budget, a sparse stack leaves gaps between its slices.

Building on such context-efficient layout, we introduce TriSegAgent (Figure 3), an MLLM agent that pairs a general-purpose MLLM with a visual harness to refine a 3D prediction through a long interactive loop. The harness does most of the volumetric computation, such as rendering the tri-planes, or moving the view, the cubic sub-region that tri-planes cut through, so that the MLLM can focus on visual judgments. Before the loop starts, the agent needs to know roughly where the target lies. Since MLLMs cannot localize the target reliably [60, 91, 116], a localization model provides a localization prior, which helps to set the first tri-planes and the initial prediction. At each step within the loop, the MLLM judges whether the prediction overlay on the tri-planes shows an error, and the harness turns this judgment into a 3D action, such as placing a click in the volume.

Figure 3. Overview of TriSegAgent. Given a volume VV and a text goal qq, the agent refines a 3D prediction until it passes multi-view verification. (a) The localization model flocf_{\mathrm{loc}} locates the target, and preprocessing turns its prior into the initial prediction M0M_0 in view v0v_0. (b) The MLLM judges the tri-planes oto_t of view vtv_t with MtM_t as an error, the interactive segmentation model fsegf_{\mathrm{seg}} turns a click ata_t into Mt+1M_{t+1}; otherwise, verification starts. (c) The MLLM judges up to KK verification views in turn; the first view with an error becomes vt+1v_{t+1}, and the agent outputs MTM_T once all views pass. (d) Click selection from candidates: ① the MLLM marks the error with a box; ② the harness places candidates in it on the correct side of the prediction boundary; ③ the MLLM picks one, which the harness maps to a 3D click ata_t; ④ fsegf_{\mathrm{seg}} proposes a prediction, which becomes Mt+1M_{t+1} only if the MLLM confirms it; otherwise, the MLLM picks another point.

To make the loop reliable, we design mechanisms around two key aspects: where to click and whether to accept the prediction. First, MLLMs judge images well but are less reliable at giving exact pixel positions [60, 91, 116], so a click that the MLLM places itself can land a few pixels off, on the wrong side of the prediction boundary. We therefore let the MLLM only mark the error and pick one of a few candidate points that the harness computes in code, so every click lands on an exact voxel on the correct side of the boundary.

Second, the tri-planes show only the area around their center, so a 3D prediction can look correct in the current view but still miss a distant part of the target. The agent therefore accepts a prediction only after it also passes in several other views spread across the target, and otherwise corrects the errors that these views show. We call this check multi-view verification: each correction needs only a local view, while the decision to accept considers the whole prediction. Under idealized assumptions, we prove that the chance of accepting a wrong prediction stays below a limit that falls geometrically with the number of views per check.

Since many annotated 3D volumes are publicly available in medical imaging, we build a diverse benchmark of 690 regions of interest (ROIs) from 35 public datasets, covering three imaging modalities. The ROIs include many small targets below 3 cm and lesion types that the interactive segmentation model was never trained on, such as gallstones and pituitary tumors. With frontier MLLMs [6, 86], TriSegAgent outperforms every baseline in overall Dice, by about 10 points over the strongest one and by more on small targets. Even with flash-level MLLMs [25, 38, 89], it outperforms nnInteractive Agent [48] running a frontier model [85]. With Gemini-3.8-Flash, tri-planes need 9.8× fewer input tokens per MLLM call than a stack of 16 parallel slices. Multi-view verification makes the agent accept fewer wrong predictions. On the localization model’s unseen datasets, TriSegAgent outperforms this model with every MLLM that we test.

Our contributions are as follows:

  • We make tri-planes the observation of the agent and show that they are context efficient, with sufficient detail to show an error region.

  • Building on tri-planes, we propose TriSegAgent, an MLLM agent for 3D volume annotation whose visual harness handles most geometric computation and the multi-view verification, so that the MLLM makes only visual judgments.

  • On 690 ROIs from 35 datasets, TriSegAgent outperforms every baseline with frontier MLLMs, and with flash-level MLLMs it still outperforms nnInteractive Agent running a frontier model.

Related Work

Context management for MLLMs on 3D volumes. A video, like a 3D volume, is a long sequence of 2D images. General-purpose MLLMs read it as frames sampled across the whole video [36, 59, 64, 105] or within the time windows that a query needs [119]. Since visual tokens grow with the number of frames, many methods compress frame tokens inside the model [62, 96, 97, 100], and accuracy still drops on longer videos [33, 126]. MLLMs read 3D volumes in the same ways: as a sequence of slices [13, 23, 37, 117], with tokens pruned inside the model [30, 69], or as a few slices, projections, or orthogonal planes through a fixed point [19, 101, 106]. In an annotation loop, the former makes every call costly, whereas the latter misses error regions elsewhere. TriSegAgent instead moves tri-planes across the volume as the observation of each step, which are context efficient yet keep sufficient detail.

Agents for interactive segmentation. Interactive segmentation models predict a target mask from clicks or boxes [47, 54, 73, 75, 103]. Like humans, MLLMs are able to interact with these models. In 2D, SegAgent [127], MedSAM-Agent [68], and IBISAgent [51] train MLLMs to output click or box coordinates, and SAM 3 agents refine text prompts [20, 66]. Medical agents also call segmentation and analysis tools [29, 41, 58, 81, 93, 95, 107], but they analyze images rather than refine a 3D prediction. In 3D, nnInteractive Agent [48] lets coding agents operate nnInteractive by reading voxel coordinates off rendered views. In TriSegAgent, the MLLM only judges tri-planes, while the harness computes every click position in code, and the agent accepts a 3D prediction only after checking it in several views. More is discussed in Sec. B.

End-to-end 3D models. Text-prompted segmentation models directly map a 3D volume and a text prompt to a segmentation mask [28, 50, 67, 92, 114, 125], while 3D MLLMs similarly rely on specialized volumetric encoders [11, 39, 111]. Although effective on in-domain targets, these approaches require additional fine-tuning to adapt to unseen domains, and lack the ability to iteratively refine their outputs. Instead, TriSegAgent iteratively verifies and corrects its predictions in a loop using a general-purpose MLLM and an open-set interactive segmentation model [47, 54], leveraging the superior transferability of frontier MLLMs to unseen settings over task-specific models [19].

Methodology

Preliminary

Viewing properties of 3D volumes. A 3D volume VV is defined on a regular voxel grid with spacing hh. To observe such a volume, image viewers [31, 110, 120] often display 2D planes through a chosen point. They render these planes from a view v=(c,F)v=(c,F), a cubic sub-region of VV with center cc and side length FF. Each plane is resampled onto an n×nn \times n pixel grid with pixel spacing F/nF/n, so at a fixed grid size, FF sets both the visible region and the finest visible detail (see Sec. C.4 for anisotropic spacing). Because a single view cannot provide both wide context and fine detail, where and at what scale to look must be balanced.

Problem formulation. Given a 3D volume VV and a text goal qq, the task is to predict the binary 3D mask of the target structure, whose ground truth M∗M^* is unknown to the agent. We formulate this task as a loop in which an agent refines a 3D prediction MtM_t at each step tt with an interactive segmentation model fsegf_{\mathrm{seg}} (Figure 1, middle-bottom). To keep each MLLM call affordable, the agent observes VV and MtM_t only through a few 2D planes rendered from its current view vt=(ct,Ft)v_t=(c_t,F_t). The agent sees only these planes, so we model this loop as a partially observable Markov decision process (POMDP) whose state includes the hidden M∗M^*:

(M∗,Mt,vt⏟state, st),R(V,Mt;vt)⏟observation, ot,at∼π(⋅∣ot,q)⏟policy(1)(1)\left(\underbrace{M^*, M_t, v_t}_{\text{state, }s_t}\right),\quad \underbrace{R(V,M_t;v_t)}_{\text{observation, }o_t},\quad \underbrace{a_t \sim\pi(\cdot\mid o_t,q)}_{\text{policy}} \qquad(1) \tag*{(1)}

where RR only renders: it draws planes of VV from vtv_t with MtM_t on them in red as an overlay (in TriSegAgent, these planes are the tri-planes; § 3.2). An action ata_t is a positive or negative click at a voxel, a move to a new view vt+1v_{t+1}, or an action that ends the loop at step TT and outputs the final prediction M=MTM=M_T. Only a click changes the prediction, through fsegf_{\mathrm{seg}}: Mt+1=fseg(V,Mt,at)M_{t+1}=f_{\mathrm{seg}}(V,M_t,a_t). The policy thus takes 2D images as input but must output actions in 3D.

Overview. TriSegAgent instantiates this POMDP as shown in Figure 3. Its observation oto_t consists of the tri-planes of vtv_t: the axial, coronal, and sagittal planes through ctc_t, each rendered as one image, with MtM_t as an overlay (§ 3.2). For brevity, we say that the MLLM judges a view when it judges the tri-planes of that view. The agent that carries out the policy π\pi consists of an MLLM and a harness, the program around the MLLM (§ 3.3). In each step, the MLLM only makes visual judgments on the tri-planes, and the harness does the rest in code.

Tri-planes as a context-efficient observation

Once the target is located, each judgment in the loop is local, since an error region of the prediction can be recognized from its surroundings. An MLLM call therefore needs only one or a few views, and showing the whole volume would spend tokens on regions that the call does not judge. Its input should instead be compact yet likely to show the error regions in its view. Tri-planes meet both needs with only three images (we drop the index tt in this section).

Context efficiency. We compare tri-planes with stacks of parallel slices, the standard way to show a volume as 2D images, for the same view. Since an MLLM turns each image into visual tokens in proportion to its pixels [13] or into a roughly fixed number of tokens [36, 59], we examine how many pixels and images a stack needs to show what tri-planes show around cc in the same detail. We measure this detail by the sampling rate rr, the number of samples per view width on each of the three planes, so that neighboring samples lie at most F/rF/r apart. Tri-planes render each plane as one n×nn \times n image, so they reach r=nr=n with 3n23n^2 pixels. A stack of NsN_s slices of n×nn \times n pixels samples the two planes that cross its slices only at its slice positions, so its sampling rate is at most min⁡(n,Ns)\min(n,N_s). Reaching sampling rate rr thus takes at least rr slices of r×rr \times r pixels, i.e., rr images and r3r^3 pixels, r/3r/3 times as many as tri-planes in either count (Figure 2a; Remark S1).

Sufficient detail. Conversely, at the same pixel budget, tri-planes show more detail than any stack. Let rtri(B)r_{\mathrm{tri}}(B) and rstack(B)r_{\mathrm{stack}}(B) denote the largest sampling rates at which tri-planes and a slice stack, respectively, show the three planes with at most B≥3B \ge3 pixels. By Corollary S1, these sampling rates satisfy:

rtri(B)=⌊B/3⌋⏟tri-planarversusrstack(B)≤B3⏟any slice stack.(2)r_{\mathrm{tri}}(B) = \underbrace{\left\lfloor\sqrt{B/3} \right\rfloor}_{\text{tri-planar}} \quad\text{versus}\quad r_{\mathrm{stack}}(B) \le\underbrace{\sqrt[3]{B}}_{\text{any slice stack}}. \tag*{(2)}

For example, with the pixels of tri-planes at n=512n=512, a stack reaches a sampling rate of at most 92. A stack that instead keeps 512×512512 \times512 slices within this budget becomes sparse: it has only three slices and leaves gaps between them (Figure 2b). These gaps can hide an error region that is thin along the stacking axis, whereas among the tri-planes, only the plane parallel to the slices can miss the region due to such thinness. For randomly placed views and slices, we prove that tri-planes are far more likely than the same number of parallel slices to show an error region in the worst case (Sec. C.1).

A harness for acting on tri-planes

To separate visual judgments from exact geometry, the harness keeps the volume VV, the 3D prediction MtM_t, and all clicks in code and shows the MLLM only rendered images. It renders the tri-planes with the overlay and maps each box or point that the MLLM selects on a plane back to voxels. This mapping needs no depth estimate: each plane is axis-aligned and passes through the known center ctc_t, so every pixel corresponds to exactly one voxel. The harness has three parts: (i) initialization starts the loop, (ii) click selection from candidates refines the prediction, and (iii) multi-view verification decides whether to accept the prediction.

Initialization. The agent starts the loop from prior knowledge of where the target lies. This prior matters because a small target appears on only a few of the hundreds of slices, so an MLLM that searches the whole scan from the text alone often misses it (§ 15.§ 1). The agent therefore takes the localization prior, a coarse mask of the target, from a localization model flocf_{\mathrm{loc}}. A preprocessing step then turns this prior into the initial state (M0,v0)(M_0,v_0) (Figure 3a; details in Sec. D.1). If the localization fails, the MLLM searches the whole scan on axial slices as a fallback, which recovers some of the targets that the localization misses.

Click selection from candidates. The agent refines the prediction with clicks: a positive click adds a missing part of the target, and a negative click removes an extra part. Each click must be exact, since a click only a few pixels off can land on the wrong side of the prediction boundary. MLLMs, however, are less reliable at giving exact pixel positions [91, 116]. The harness therefore splits each click into four sub-steps (Figure 3d): the MLLM only locates the error roughly and picks among candidate points, and the harness computes every exact position in code. ① The MLLM draws a rough box around a missing or an extra part on one plane. Because a click on a false alarm would damage a correct part of the prediction, the harness checks each box before clicking. It first drops any box that contradicts the overlay, e.g., a box that the MLLM marks as a missing part although the overlay already covers most of it. For each remaining box, the harness renders a new view centered on the box, so that the MLLM can examine the error in all three planes before confirming or withdrawing it. ② Let btb_t denote the set of voxels that the box covers on its plane. Inside btb_t, the harness samples N≤5N \le5 candidate points x1,…,xNx_1,\ldots,x_N on the correct side of the prediction boundary:

xj∈{bt∖Mtmissing part (positive click),bt∩Mtextra part (negative click),(3)x_j \in \begin{cases} b_t \setminus M_t & \text{missing part (positive click)},\\ b_t \cap M_t & \text{extra part (negative click),} \end{cases} \tag*{(3)}

and draws them as rings with numbers on the plane of the box. ③ The MLLM picks one number j∗j^*, and the harness maps it to the exact voxel xj∗x_{j^*}. The click label ℓt\ell_t is +1+1 for a missing part and −1-1 for an extra part, so the action is at=(xj∗,ℓt)a_t=(x_{j^*},\ell_t). ④ fsegf_{\mathrm{seg}} turns this click into a proposed prediction, which becomes Mt+1M_{t+1} only if it passes basic checks and the MLLM confirms its overlay; otherwise, the harness undoes the click (Sec. D.2). The MLLM thus never outputs a click position, yet every click lands at an exact voxel on the correct side of the prediction boundary.

Multi-view verification. Tri-planes show the 3D prediction only as three cross-sections within one view, so the MLLM may accept the overlay in one view even when the prediction misses a distant part of the target or spills into a nearby organ. The prediction must therefore also pass in other views, and the following property of a click shows where new error regions can appear:

Remark 1 (Where new error regions can appear). An error region is a connected component of voxels where the prediction and M∗M^* disagree, away from the boundary of M∗M^*, as long as the component covers at least a fixed fraction of the target volume (Sec. E.1). Let Δt\Delta_t denote the region where Mt+1M_{t+1} and MtM_t differ. Since a click changes the prediction only inside Δt\Delta_t, every error region of Mt+1M_{t+1} that does not intersect Δt\Delta_t was already part of an error region of MtM_t. For the same reason, if a view’s planes do not intersect

Δt\Delta t, its tri-planes remain unchanged, so the MLLM does not need to judge this view again.

Since the harness knows Δt\Delta t from the two predictions, it places one view on this region to check for new error regions. Error regions that existed before the click can lie anywhere, so the other views cover the places where a prediction often goes wrong: its center, its surface, and its separate pieces. Together, these views, at most KK of them, form the verification views V(Mt)\mathcal{V}(M_t) (Figure 3c), and the supplement describes how the harness places them, including the extra views after a large correction (Sec. D.3). After each correction, the agent verifies the updated prediction again, and it accepts the prediction once all views of a verification pass. Under the idealized assumptions below, the chance that the agent accepts a wrong prediction during the whole run stays below a limit that falls geometrically as each verification uses more views (proof in Sec. E.4):

Corollary 1 (Reaching a prediction without error regions). Assume that M0M_0 has NerrN_{\mathrm{err}} error regions and that three conditions hold: (i) correct judgments, i.e., the MLLM judges every view correctly; (ii) coverage, i.e., in every verification, at least kk views each show a remaining error region with probability at least pcovp_{\mathrm{cov}}, even after earlier views have missed it; and (iii) clean corrections, i.e., each error that the MLLM confirms leads to a correction that clears at least one error region of M0M_0 without expanding an existing error region or introducing a new one. Without budget limits, the agent then accepts a prediction without error regions within NerrN_{\mathrm{err}} corrections with probability at least 1−E[Nerr](1−pcov)k1-\mathbb{E}[N_{\mathrm{err}}](1-p_{\mathrm{cov}})^k, where probabilities are taken over the unknown M∗M^* given what the agent has observed.

Keeping the failure bound E[Nerr](1−pcov)k\mathbb{E}[N_{\mathrm{err}}](1-p_{\mathrm{cov}})^k below a target level α\alpha thus requires only k≥log⁡(E[Nerr]/α)/log⁡11−pcovk \ge\log(\mathbb{E}[N_{\mathrm{err}}]/\alpha)/\log\frac{1}{1-p_{\mathrm{cov}}} views, a number that grows logarithmically with E[Nerr]/α\mathbb{E}[N_{\mathrm{err}}]/\alpha. The agent knows neither NerrN_{\mathrm{err}} nor pcovp_{\mathrm{cov}}, so the harness instead uses a fixed rule with at most KK views (Sec. D.3). The coverage pcovp_{\mathrm{cov}} depends on the target and on the size and shape of each error region. For error regions that cover at least 10% of the target, the first view of a verification already shows one in more than 90% of the verifications whose prediction has one (§ 15.§ 3). However, the real loop departs from assumptions (i) and (iii): the MLLM does not always judge correctly, and a correction can create new error regions (Remark 1). When the MLLM misses an error region that a view shows, the agent may accept a clearly wrong prediction, which happens in a small fraction of cases (§ 4.3); when it stays unsure about a view after two retries, the agent stops without accepting the prediction (Sec. D.3). Sec. E.4 gives a bound on the outcome when (i) or (iii) fails.

Experiments

We evaluate TriSegAgent with three research questions: RQ1 (Table 1 and Figure 6): Can it annotate ROIs of different types and sizes automatically and reliably? RQ2 (Figure 5): Do tri-plane prompts provide a more context-efficient observation? RQ3 (§ 4.3): How does each design of the harness, namely the initial prediction, click selection from candidates, and multi-view verification, contribute to the annotation?

Table 1. Performance on the benchmark. The Lesion group covers lymph nodes and lesions (tumors, stones, cysts, and stroke lesions). Oracle: fsegf_{\mathrm{seg}} with five iterative clicks from the ground truth, shown as a reference. SegVol scores zero on 365 of the 690 ROIs, so its median is zero. The number in parentheses after each mean is the half-width of its 95% confidence interval, from resampling the ROIs (Sec. J).

CategoryMethodMLLMOverall MeanOverall MedianOrganMuscleVesselBoneLesionLymph nodeSmallLarge
ReferenceOracle (5 clicks)78.984.581.282.680.135.776.773.971.783.2
End-to-endSegVol [28]26.3 (2.8)0.037.01.553.20.07.00.08.037.3
M3D-LaMed [11]Phi-3-4B [1]26.8 (2.5)4.238.916.250.60.05.02.98.438.0
Text3DSAM [114]44.8 (2.3)47.952.355.952.333.731.032.927.455.3
SAT-Pro [125]50.1 (2.8)65.266.110.672.40.225.60.031.061.7
VoxTell [92]58.4 (2.5)71.269.360.871.230.841.212.341.568.7
2D agentMedSAM-Agent [68]Qwen3-VL-8B [12]30.1 (2.5)14.241.40.033.90.913.81.27.443.8
3D agentnnInteractive Agent [48]GPT-5.6-Sol [84]36.7 (2.9)21.034.646.125.828.543.517.820.246.8
Claude-Sonnet-5.5 [7]44.3 (2.9)49.045.865.133.933.744.024.023.756.7
GPT-6.1-Sol [85]59.7 (2.5)72.464.542.362.637.054.136.342.370.3
OursTriSegAgentGPT-5.6-Sol [84]64.2 (2.3)74.970.868.469.620.754.447.951.372.0
Claude-Sonnet-5.5 [7]63.2 (2.5)75.772.375.371.529.247.548.447.472.8
GPT-6.1-Sol [85]68.8 (2.1)80.074.178.074.623.961.251.654.377.6
DeepSeek-V4.1-Flash [25]64.7 (2.5)77.974.075.374.122.449.347.546.575.7
Gemini-3.8-Flash [38]66.3 (2.3)78.775.177.870.924.552.448.151.575.3
Claude-Opus-5.5 [6]69.2 (2.2)80.576.078.875.028.958.849.052.879.0
GPT-6-Astra [86]70.0 (2.1)80.175.278.075.429.062.750.955.678.7

Table 1.

Context efficiency plots for slice stack, 3 slices in one image, and tri-planes

Figure 5. Context efficiency of the input layout. Only the input layout differs between the lines. Slice stack: parallel axial slices around the view center, one image per slice; tri-planes always show three planes, so they appear as a dashed line.

Dice on seen and unseen datasets

Figure 6. Generalization to unseen datasets. Dice of flocf_{\mathrm{loc}}, of floc→fsegf_{\mathrm{loc}}\to f_{\mathrm{seg}} (no MLLM), and of TriSegAgent with Gemini-3.8-Flash and GPT-6-Astra on the seen (480 ROIs) and unseen (210 ROIs) datasets of flocf_{\mathrm{loc}}.

Experiment Setup

Benchmark. We prioritize diversity of ROI types over the number of cases per type (Sec. F). The benchmark comprises 690 ROIs in 262 volumes from 35 public CT, MR, and PET datasets, covering organs, vessels, bones, muscles, tumors, and lymph nodes. We call an ROI small when the equivalent spherical diameter of its ground-truth mask is below 3 cm (260 ROIs) and large otherwise (Sec. F). It also includes lesion types from datasets that neither flocf_{\mathrm{loc}} nor fsegf_{\mathrm{seg}} saw in training [44, 63, 87, 113]. For in-distribution datasets, we take only validation or test cases (Sec. F). To limit API costs, we use a 190-ROI subset for all experiments except Table 1 and Figure 6 (Sec. F). This subset still covers every target of the benchmark, since it keeps at least one ROI for each target of each dataset. Outside Table 1, TriSegAgent runs with Gemini-3.8-Flash unless noted otherwise, and § 15.§ 2 and § 15.§ 3 repeat the input-layout comparison and the ablation with DeepSeek-V4.1-Flash.

Baselines and metrics. We compare TriSegAgent with five end-to-end 3D segmentation models, VoxTell [92], SAT-Pro [125], Text3DSAM [114], SegVol [28], and M3D-LaMed [11], and the 2D agent MedSAM-Agent [68], using weights from their official repositories. The five end-to-end segmentation models receive only the target name, whereas MedSAM-Agent segments slice by slice within the slice range of the flocf_{\mathrm{loc}} box. As a 3D agent baseline, we run nnInteractive Agent [48] in its default configuration, using Codex [83] with GPT-6.1-Sol or GPT-5.6-Sol, and Claude Code [5] with Claude-Sonnet-5.5. Sec. G gives more detailed settings of all systems. To test whether our designs can be helpful for general coding agents, we evaluate Codex [83] with GPT-6.1-Sol [85], which drives the same fsegf_{\mathrm{seg}} (Sec. H). We evaluate every system with 3D Dice (%). For the agents, we also report MLLM calls per ROI and the number of false accepts (FA). In all tables, the best and second-best results are bolded and underlined.

Implementation details. We implement TriSegAgent as a finite-state machine in LangGraph [56], with BioMed-Parse v2 [123, 124] as flocf_{\mathrm{loc}} and nnInteractive [47] as fsegf_{\mathrm{seg}}. In practice, the harness places the three planes of each view side by side in one image. All MLLMs in Table 1 use identical prompts and their default reasoning effort. We tuned the prompts and parameters of the agent, such as the number of verification views KK, on a separate 74-ROI development set that shares no cases with the benchmark (Sec. F). The agent makes at most 26 MLLM calls for each ROI (§ 15 varies this budget). All experiments run on a single NVIDIA RTX 4090 GPU.

Results

Performance on our benchmark. With each MLLM, TriSegAgent achieves a higher overall Dice than every baseline, and frontier MLLMs give it the highest Dice (Table 1). With the same MLLM, it outperforms nnInteractive Agent for each of the three MLLMs that both agents run, and even with a flash-level MLLM, it outperforms nnInteractive Agent running a frontier model. The other baselines learn their targets from training data and generalize poorly: on rare lesion types such as gallstones and pituitary tumors, they score far lower than both agents. With frontier MLLMs, the lead of TriSegAgent over the strongest baseline is even larger on small targets (Figure 4). Unlike nnInteractive Agent, TriSegAgent’s harness computes click position through code to avoid missing small targets. With frontier MLLMs, TriSegAgent also leads on every ROI type except bones. All ten bone ROIs come from MR scans, and even fsegf_{\mathrm{seg}} with clicks from the ground truth separates them poorly from nearby tissue. For TriSegAgent, a box around a thin or curved part of a bone also covers mostly other tissue, so its candidate points may not land on the bone.

Comparison of small-target segmentation

Figure 4. Comparison of small-target segmentation. The three targets measure 13, 21, and 22 mm from top to bottom; gray is the ground truth and orange the 3D prediction, and a panel without orange has no prediction in view. nnI-Agent: nnInteractive Agent [48] with GPT-6.1-Sol [85]. Sec. K shows more cases.

Context efficiency of tri-planes. Tri-planes are the most context-efficient input layout while preserving performance (Figure 5; § 15.§ 2). For a slice stack, the input tokens per call increase with the number of slices, whereas its Dice does not improve and stays below that of tri-planes. Tri-planes use the fewest input tokens per MLLM call (up to 9.8×9.8\times fewer than a 16-slice stack), yet their detail is sufficient for the annotation. They also need the fewest reasoning tokens and calls, which gives them the lowest API cost per ROI.

Generalization to unseen datasets. On the unseen datasets of flocf_{\mathrm{loc}}, TriSegAgent outperforms both flocf_{\mathrm{loc}} and floc→fsegf_{\mathrm{loc}\to f_{\mathrm{seg}}}, in which fsegf_{\mathrm{seg}} segments the target from the mask of flocf_{\mathrm{loc}}

without an MLLM (Figure 6; § 15.§ 1). The Dice of both drops sharply from the seen to the unseen datasets, whereas that of TriSegAgent with Gemini-3.8-Flash or GPT-6-Astra remains stable across the two. Since fsegf_{\mathrm{seg}} raises the Dice of flocf_{\mathrm{loc}} only slightly on the unseen datasets, the stable Dice of TriSegAgent comes from the agent rather than from fsegf_{\mathrm{seg}}. TriSegAgent does not simply accept the prior: it checks the initial prediction from the prior in tri-planes and corrects it through clicks, and when flocf_{\mathrm{loc}} finds nothing, it searches the whole scan for the target on its own. With frontier MLLMs, TriSegAgent also outperforms flocf_{\mathrm{loc}} over all ROIs (§ 15.§ 1). Generalizability to other agents. Tri-planes and the localization prior help other agents (Table 2). Compared with

MethodObservation InputPriorDice MeanDice MedianDice SmallDice LargeBehavior FA↓Behavior Calls↓
Codex [83]volume×62.374.643.673.02827.8
axial×55.268.340.763.44229.9
tri-planes×53.866.437.763.04624.2
tri-planes✓63.074.746.972.31925.1
nnInteractive Agent [48]default×34.214.313.645.9––
default✓58.975.444.567.1––
TriSegAgenttri-planes✓65.879.349.375.31211.7

Table 2. Generalization of the harness design to other agents. Prior: the first view comes from flocf_{\mathrm{loc}}. Codex accepts every prediction that it submits, and its calls are the turns that ran a command; –: not recorded. Codex runs GPT-6.1-Sol and nnInteractive Agent runs GPT-5.6-Sol.

axial slices, tri-planes let Codex reach a similar Dice with fewer calls, due to their sufficient detail. The prior brings the largest gain to both Codex and nnInteractive Agent, because it starts both agents at the target. Even with both designs, Codex with a frontier MLLM scores below TriSegAgent with a flash-level MLLM and needs 2.1× as many calls, because without our harness, its MLLM must give every click position itself.

Ablation Study

Prior mask for initialization. Initializing fsegf_{\mathrm{seg}} with the prior mask instead of a single click raises the mean Dice by 12.8 points and halves the false accepts (Table 3). Since an interactive model such as fsegf_{\mathrm{seg}} is sensitive to its first prompt, and later clicks only refine the prediction that this prompt produces [47, 65], outlining the whole target gives a much better start than marking one point.

Prior maskClick selectionMulti-view verificationDice MeanDice MedianDice SmallDice LargeFA↓
×✓✓53.063.837.162.125
✓×✓61.477.944.671.015
✓✓×65.179.148.574.616
✓✓✓65.879.349.375.312

Table 3. Ablation of the harness. × marks a removed design, and the shaded row is the full TriSegAgent. Without the prior mask, fsegf_{\mathrm{seg}} starts from one click that the harness places on the same view; without click selection, the MLLM outputs the coordinates of every click itself.

Click selection from candidates. Selecting among candidate points, rather than letting the MLLM output raw coordinates, raises the mean Dice on both small and large targets (Table 3). The gain comes from exact clicks: the harness places every candidate on an exact voxel on the correct side of the prediction boundary (§ 3.3). For example, Figure 8 shows how the MLLM picks candidates on the liver.

Figure 8. One click of TriSegAgent on the liver (CT, AbdomenAtlas). The red overlay is the 3D prediction before (left) and after (right) the click; the middle panel enlarges the blue box with the candidate points.

Multi-view verification. Multi-view verification reduces the accepted ROIs with Dice below 50% for both MLLMs (Figure 7); with Gemini-3.8-Flash, it also lowers the false accepts and raises the mean Dice (Table 3). Without it, the agent accepts a prediction as soon as a single view passes, so it accepts more wrong predictions (Table 3). It helps both compact ROIs and ROIs with complex shapes such as the tubular aorta (§ 15).

Accepted ROIs with and without multi-view verification for DeepSeek-V4.1-Flash and Gemini-3.8-Flash

Figure 7. Accepted ROIs with Dice below 50%, with and without multi-view verification.

Conclusion

We presented TriSegAgent, an MLLM agent that annotates 3D volumes through an interactive loop with a segmentation model. The agent observes the volume through tri-planes, which keep each MLLM call compact yet likely to show error regions in the 3D prediction. Within the agent, the MLLM only judges the prediction on tri-planes, while the harness turns each judgment into a 3D action in code and checks each 3D prediction from several views before the agent accepts it. With frontier MLLMs, TriSegAgent achieves a higher overall Dice than every baseline, and with flash-level MLLMs, it still outperforms nnInteractive Agent running a frontier model. Tri-planes use up to 9.8× fewer input tokens per MLLM call than a 16-slice stack, without loss in performance.

LLM Usage Statement

The MLLMs and coding agents in Table 1 and Table 2 are the subject of our experiments and run as part of the evaluated systems. Separately, we used generative AI tools (Claude Code and Codex) to draft and edit this paper, including the LaTeX of its tables and the source code of its figures. We also used them when debugging the research code and managing the experiments. For the related work, these tools helped us find references, and we manually checked that every citation is correct.

Notation and Terminology

Table S1 lists the terms that the paper uses with a fixed meaning (left) and the symbols of the main paper and of Sec. D (right). The agent consists of an MLLM for visual judgments and a harness for rendering, tool calls, and the geometry of views and candidate points. Symbols that appear only inside a proof in Sec. C or Sec. E are defined in that proof.

(a) Terms(b) Symbols
TermMeaningSymbolMeaning
MLLMA general-purpose multimodal large language model; it sees only rendered images and returns visual judgments, e.g.e.g., a box, a candidate number, or a decision to accept.V,hV, hVolume; its voxel spacing
HarnessThe program around the MLLM; it keeps VV and MtM_t, renders views, calls flocf_{\mathrm{loc}} and fsegf_{\mathrm{seg}}, and computes the geometry of views and candidates in code.v=(c,F)v=(c,F)View with center cc and side length FF
AgentThe MLLM and the harness together; it clicks, moves to the next view, and either accepts the prediction or stops without accepting it.nnImage side length in pixels
MLLM agentAny agent whose decisions come from an MLLM, e.g.e.g., TriSegAgent, a 2D segmentation agent, or a coding agent.rrSampling rate: samples per view width on each plane
TriSegAgentOur agent, with tri-planes as observations, click selection from candidates, and multi-view verification.BBPixel budget of an observation
ViewA cubic region v=(c,F)v=(c,F) of VV with center cc and side length FF.DDTotal number of slices in the volume
Tri-planesThe axial, coronal, and sagittal planes through the center cc of a view, each rendered as one image, with MtM_t drawn as an overlay.rtri,rstackr_{\mathrm{tri}},r_{\mathrm{stack}}Largest integer sampling rate with at most BB pixels: tri-planes; stack
OverlayThe 3D prediction MtM_t drawn in red on the tri-planes.qqText goal
Verification viewA view centered on another part of MtM_t, which the MLLM judges before the agent accepts MtM_t.M∗,MM^*,MGround-truth 3D mask; final prediction
Localization priorThe coarse 3D prediction PP that flocf_{\mathrm{loc}} outputs for qq; it centers v0v_0 and seeds M0M_0.Mt,M0M_t,M_03D prediction at step tt; initial prediction
Initial predictionM0M_0, which the MLLM chooses from two proposals that fsegf_{\mathrm{seg}} grows from the main component of PP and from a point.st,ot,ats_t,o_t,a_tState, observation, and action at step tt
ProposalA new prediction, for M0M_0 or from a click, which the harness commits only if it passes the basic checks and the MLLM confirms it.π,R\pi,RPolicy; renderer of planes with the overlay
ClickA positive or negative point prompt to fsegf_{\mathrm{seg}} at one voxel.T,TaccT,T_{\mathrm{acc}}Actual stopping time; acceptance time
CandidateA point inside the box of an error that the MLLM confirms; the harness samples it and draws it as a numbered ring.floc,Pf_{\mathrm{loc}},PLocalization model; localization prior
Error regionA connected component of voxels where a prediction and M∗M^* disagree, away from the boundary of M∗M^* and covering at least a fixed fraction of the target volume (Sec. E.1).fsegf_{\mathrm{seg}}Interactive segmentation model
Confirm an errorThe MLLM marks an error with a box and keeps the box through the box check and the confirmation view.btb_tVoxel set of the MLLM’s box on its plane
AcceptThe agent returns MTM_T after every verification view passes.x1,…,xNx_1,\ldots,x_NCandidate points in btb_t, with N≤5N\leq5
Stop without acceptanceThe agent stops without accepting the prediction and records the reason and the views that it could not confirm.j∗,ℓtj^*,\ell_tSelected candidate number; click label (±1)(\pm1)
V(Mt),K\mathcal{V}(M_t),KVerification views of MtM_t; their largest number
χt\chi_tWhether every view in V(Mt)\mathcal{V}(M_t) passes (1) or not (0)
Kt+,Kt−\mathcal{K}_t^+,\mathcal{K}_t^-Voxel positions of positive and negative clicks up to step tt
Δt\Delta_tVoxels that step tt changes, Mt+1△MtM_{t+1}\triangle M_t
NerrN_{\mathrm{err}}Number of error regions of M0M_0
P0P_0Main component of PP
c0,F0c_0,F_0Center and side length of the initial view v0v_0
d(x,∂P0)d(x,\partial P_0)Distance from voxel xx to the boundary of P0P_0
M~\widetilde{M}Proposed prediction, including each proposal for M0M_0

Table S1. Notation and terminology. (a) Terms that the paper uses with a fixed meaning. (b) Symbols of the main paper and of Sec. D.

Extended Related Work

Interactive segmentation tools. Interactive segmentation tools turn a few clicks into a prediction, but they leave the annotator to decide where this prediction is still wrong [77, 82]. RITM [99] and SAM [54] feed the previous prediction back into the model, so that each later click corrects this prediction instead of segmenting the target again. Medical tools bring this loop to 3D volumes: MedSAM2 [75] propagates a 2D prediction from a prompted slice through the volume, whereas SAM-Med3D [103], SegVol [28], and nnInteractive [47] predict a 3D mask directly from each prompt. In nnInteractive, a prompt on any axial, sagittal, or coronal slice updates the whole 3D mask [47], so one correction can change the prediction beyond the part that was wrong [82]. Annotators therefore evaluate the updated 3D mask on screen before the next correction [75, 82]. Throughout this loop, the tool draws the prediction, and the annotator supplies only the decision of where to place a positive or a negative click. TriSegAgent keeps the interactive segmentation model fsegf_{\mathrm{seg}} unchanged and lets an MLLM make this decision, so it runs with either nnInteractive or MedSAM2 as fsegf_{\mathrm{seg}} (Tab. S17).

Simulated annotators. Interactive segmentation tools are trained with simulated annotators that make this click decision from the ground truth [47, 54, 99], and benchmarks evaluate them with the same simulators [78]. The common rule places the next click inside an error region between the prediction and the ground truth: a positive click where the target is missing, and a negative click where the prediction is extra [54, 78, 99]. MLLM agents for interactive segmentation are trained on the same simulators: SegAgent [127], MedSAM-Agent [68], and IBISAgent [51] fine-tune MLLMs on click trajectories that a rule-based simulator derives from ground-truth masks. MedSAM-Agent and IBISAgent then apply reinforcement learning with rewards computed against the ground truth. TriSegAgent keeps the click rule of these simulators but replaces the ground truth with the judgment of a general-purpose MLLM on tri-planes. Once the MLLM confirms a missing or an extra part, the harness samples candidate points on the matching side of the prediction boundary (Eq. (3)), and the MLLM picks one of them. TriSegAgent thus places every click without ground truth, unlike a simulated annotator, and needs no training of the MLLM, unlike these agents. Because TriSegAgent needs no ground truth, it can also record click trajectories on unannotated volumes, where a simulated annotator cannot run. Each MLLM call in such a trajectory is a self-contained pair of images and one decision, since no history passes between calls. Such trajectories could thus serve as training data for a smaller MLLM that runs locally, enabling privacy-preserving deployment of such agents.

Theory of Tri-Planes

This section supports the choice of tri-planes in § 3.2. Once the target is located, each judgment of the agent is local, since an error region can be recognized from its surroundings and a click creates new error regions only where it changes the prediction (Sec. E.1). A call therefore needs one or a few views rather than the whole volume. These few views must thus rarely miss an error. For randomly placed views and slices, tri-planes are far more likely to show a set of errors in the worst case than the same number of parallel slices (Sec. C.1). Parallel slices can catch up only with more images, so we then count the pixels that tri-planes and slice stacks need to show the three planes through the view center in the same detail (Secs. C.2 to C.4).

Error Detection by Tri-Planes

A view shows an error when one of its three images contains this voxel at the image resolution, and it misses a set of errors when it shows none of them. We establish a bound on the probability that randomly placed tri-planes miss a set of errors, and compare this probability with that of parallel slices using the same number of images.

Proposition S1 (Error detection by tri-planes). Let UU be a box of voxels, and let E⊆UE \subseteq U be a nonempty set of errors, connected or not, with volume fraction ϵ=∣E∣/∣U∣\epsilon= |E|/|U|. Suppose that the centers of kk views are drawn independently and uniformly from the voxels of UU, that each of 3k3k parallel slices lies in a layer drawn independently and uniformly along its axis, and that every plane shows its whole cross-section of UU at voxel resolution. Then: (a) all kk views miss EE with probability at most (1−ϵ1/3)3k(1-\epsilon^{1/3})^{3k}; (b) the probability that all kk views miss EE is at most the probability that 3k3k parallel slices along an axis drawn uniformly at random all miss EE, with equality only when EE occupies the same fraction of layers along each axis; and (c) if EE consists of two layers along one axis, 3k3k parallel slices along this axis all miss EE with probability (1−ϵ)3k(1-\epsilon)^{3k}, whereas every view shows EE.

Proof. Let axa_x, aya_y, and aza_z be the fractions of layers along the three axes that contain a voxel of EE. A view misses EE only when all three of its layers miss EE, and the three coordinates of a uniform center are independent, so:

Pr⁡(one view misses E)=(1−ax)(1−ay)(1−az).\Pr(\text{one view misses }E)=(1-a_x)(1-a_y)(1-a_z).

(a) Since EE lies inside the product of its occupied layers, ϵ≤axayaz\epsilon\le a_xa_ya_z, and the inequality of arithmetic and geometric means gives (axayaz)1/3+[(1−ax)(1−ay)(1−az)]1/3≤1(a_xa_ya_z)^{1/3}+[(1-a_x)(1-a_y)(1-a_z)]^{1/3}\le1. One view therefore misses EE with probability at most (1−ϵ1/3)3(1-\epsilon^{1/3})^3, and the independence of the centers gives:

Pr⁡(all k views miss E)≤(1−ϵ1/3)3k.(4)\Pr(\text{all }k\text{ views miss }E)\le(1-\epsilon^{1/3})^{3k}. \tag*{(4)}

(b) A slice along axis ℓ∈{x,y,z}\ell\in\{x,y,z\} misses EE with probability 1−aℓ1-a_\ell, so 3k3k slices along a uniformly drawn axis all miss EE with probability 13∑ℓ(1−aℓ)3k\frac{1}{3}\sum_\ell(1-a_\ell)^{3k}. By the inequality of arithmetic and geometric means, this average is at least [∏ℓ(1−aℓ)3k]1/3=\left[\prod_\ell(1-a_\ell)^{3k}\right]^{1/3}= ∏ℓ=13(1−aℓ)k\prod_{\ell=1}^{3}(1-a_{\ell})^{k}, the probability that all kk views miss EE, with equality only when ax=ay=aza_x=a_y=a_z. (c) Let the axis be zz. Then az=εa_z=\varepsilon, so each axial slice misses EE with probability 1−ε1-\varepsilon, whereas ax=1a_x=1 means that every sagittal plane contains a voxel of EE, so every view shows EE.

Parts (a) and (c) compare the worst cases: the kk views show every EE with probability at least 1−(1−ε1/3)3k1-(1-\varepsilon^{1/3})^{3k}, whereas 3k3k parallel slices along a fixed axis show an EE that fills whole layers along this axis only with probability 1−(1−ε)3k1-(1-\varepsilon)^{3k}. For small ε\varepsilon, the first probability is far larger, since ε1/3≫ε\varepsilon^{1/3}\gg\varepsilon. In the worst case, tri-planes are thus far more likely than the same number of parallel slices to show a set of errors. Part (b) holds for every EE: when the orientation of the errors is unknown, tri-planes miss them no more often than parallel slices along an axis chosen at random. The proposition draws views at random to compare the two layouts alone, whereas the harness centers each view on a chosen point. For a view centered at the centroid of a component, Lemma S2 shows that all three of its planes cut that component.

Pixel Budget of Tri-Planes and Slice Stacks

Part (c) of Proposition S1 shows that parallel slices can miss errors that lie in the gaps between them, and a stack can close these gaps only by adding slices. Accordingly, we count the pixels needed for an observation to sample the three orthogonal planes through the view center.

Sampling positions and coverage. Let F>0F>0 denote the side length of the cubic view Q=[0,F]3Q=[0,F]^3 in local coordinates, centered at c=(cx,cy,cz)=(F/2,F/2,F/2)c=(c_x,c_y,c_z)=(F/2,F/2,F/2). The axial, coronal, and sagittal planes within QQ are given by:

A={(x,y,cz):x,y∈[0,F]},C={(x,cy,z):x,z∈[0,F]},S={(cx,y,z):y,z∈[0,F]}.\begin{aligned} \mathcal{A}&=\{(x,y,c_z):x,y\in[0,F]\},\\ \mathcal{C}&=\{(x,c_y,z):x,z\in[0,F]\},\\ \mathcal{S}&=\{(c_x,y,z):y,z\in[0,F]\}. \end{aligned}

Let Π=A∪C∪S\Pi=\mathcal{A}\cup\mathcal{C}\cup\mathcal{S} denote the target region that the observation must sample.

A rendered pixel samples the intensity V(p)V(p) at a position p∈Qp\in Q; resampling allows this position to lie between voxel centers. Let Ω⊂Q\Omega\subset Q denote the nonempty finite set of distinct sampling positions. The pixel budget BB counts every rendered pixel, including pixels that repeat a position, so an observation within budget BB has ∣Ω∣≤B|\Omega|\le B.

We measure how well Ω\Omega covers Π\Pi by the distance between a target point u∈Πu\in\Pi and a sample p∈Ωp\in\Omega in the ℓ∞\ell_\infty norm:

∥u−p∥∞=max⁡{∣ux−px∣,∣uy−py∣,∣uz−pz∣}.\lVert u-p\rVert_\infty=\max\{|u_x-p_x|,|u_y-p_y|,|u_z-p_z|\}.

The coverage radius is the largest distance from a target point to its nearest sample:

δ(Ω)=max⁡u∈Πmin⁡p∈Ω∥u−p∥∞.(5)\delta(\Omega)=\max_{u\in\Pi}\min_{p\in\Omega}\lVert u-p\rVert_\infty. \tag*{(5)}

A small δ(Ω)\delta(\Omega) thus means that every point on the three planes lies close to a sample. We say that an observation achieves sampling rate rr if every target point lies within F/(2r)F/(2r) of a sample along each coordinate:

δ(Ω)≤F2r.\delta(\Omega)\le\frac{F}{2r}.

For example, a uniform r×rr\times r grid on one plane places its samples F/rF/r apart along both in-plane axes, with the outermost samples F/(2r)F/(2r) from the boundary. Every point on this plane is then within F/(2r)F/(2r) of a sample along both in-plane axes and at distance zero along the normal axis.

Within radius ρ\rho, each sample covers a cube of side length 2ρ2\rho, and this cube meets a plane through the sample in a square of the same side length. The coverage radius δ(Ω)\delta(\Omega) is thus the smallest ρ\rho at which these cubes cover Π\Pi. A cube marks only the positions near a sample; it does not assume that the intensity inside the cube is constant or known. Below, all sampling rates and image side lengths are positive integers.

Input layouts: tri-planes and slice stack. Tri-planes sample each target plane on a uniform n×nn\times n grid. Let GnG_n denote the centers of the nn equal intervals of [0,F][0,F]:

Gn={(i−12)Fn:i=1,…,n}.G_n=\left\{\left(i-\frac{1}{2}\right)\frac{F}{n}:i=1,\ldots,n\right\}.

Placing the grid Gn×GnG_n \times G_n on the two in-plane coordinates of each plane gives three images with 3n23n^2 pixels in total. Let Ωtri\Omega_{\mathrm{tri}} denote the resulting set of sampling positions. Every point on Π\Pi lies within F/(2n)F/(2n) of a sample in its plane, and a boundary point (e.g., (0,0,cz)(0,0,c_z)) reaches this distance, giving:

δ(Ωtri)=F2n.\delta(\Omega_{\mathrm{tri})} = \frac{F}{2n}.

A slice stack along the zz-axis instead renders NsN_s parallel slices at depths ζ1,…,ζNs∈[0,F]\zeta_1,\ldots,\zeta_{N_s} \in[0,F]. All slices sample the same grid X×YX \times Y, where X,Y⊂[0,F]X,Y \subset[0,F] with ∣X∣=∣Y∣=m|X|=|Y|=m. The stack thus samples the positions:

Ωstack={(ξ,η,ζk):ξ∈X, η∈Y, k=1,…,Ns},\Omega_{\mathrm{stack}} = \{(\xi,\eta,\zeta_k): \xi\in X,\ \eta\in Y,\ k=1,\ldots,N_s\},

which requires Nsm2N_s m^2 rendered pixels. The slice depths {ζk}\{\zeta_k\} and the grid coordinates X,YX,Y may be spaced unevenly. Stacks along the xx- and yy-axes follow by permuting the coordinates.

One-dimensional covering. The lower bound on the pixels of a slice stack rests on covering an interval.

Lemma S1 (Covering). Let H⊂[0,F]H \subset[0,F] be a finite set that covers [0,F][0,F] within radius ρ>0\rho> 0. Then ∣H∣≥F/(2ρ)|H| \ge F/(2\rho).

Proof. Each point in HH covers an interval of length at most 2ρ2\rho, so the ∣H∣|H| intervals have a total length of at most 2ρ∣H∣2\rho|H|. Since they must cover [0,F][0,F], we have:

2ρ∣H∣≥F,and thus∣H∣≥F2ρ.2\rho|H| \ge F,\qquad\text{and thus}\qquad|H| \ge\frac{F}{2\rho}.

Remark S1 (Pixel budget). Tri-planes achieve sampling rate rr using 3r23r^2 rendered pixels, whereas any slice stack achieving sampling rate rr requires at least r3r^3 rendered pixels.

Proof. Set ρ=F/(2r)\rho= F/(2r). Since δ(Ωtri)=F/(2n)\delta(\Omega_{\mathrm{tri}})=F/(2n), the sampling rate of tri-planes equals the number of pixels nn along each side of their images. Tri-planes with three r×rr \times r images thus reach δ(Ωtri)=ρ\delta(\Omega_{\mathrm{tri}})=\rho using 3r23r^2 pixels.

For a slice stack along zz, consider the coronal plane CC, which spans [0,F][0,F] along both xx and zz. To achieve sampling rate rr, every point (x,cy,z)∈C(x,c_y,z) \in C must lie within ρ\rho of some sample (ξi,ηj,ζk)∈Ωstack(\xi_i,\eta_j,\zeta_k) \in\Omega_{\mathrm{stack}}, which implies:

∣x−ξi∣≤ρand∣z−ζk∣≤ρ.|x-\xi_i| \le\rho\qquad\text{and} \qquad|z-\zeta_k| \le\rho.

Because xx and zz vary independently over [0,F][0,F], both XX and {ζ1,…,ζNs}\{\zeta_1,\ldots,\zeta_{N_s}\} must cover [0,F][0,F] within radius ρ\rho. Applying Lemma S1 to each axis gives:

m=∣X∣≥F2ρ=r,Ns≥F2ρ=r.m=|X| \ge\frac{F}{2\rho}=r,\qquad N_s \ge\frac{F}{2\rho}=r.

The stack therefore needs at least Nsm2≥r3N_s m^2 \ge r^3 rendered pixels. The same argument holds for stacks along xx or yy, with a target plane that contains the stacking axis.

Corollary S1 (Fixed budget). Given a budget of B≥3B \ge3 pixels, the maximum integer sampling rates achievable by tri-planes and a slice stack satisfy:

rtri(B)=⌊B/3⌋,rstack(B)≤B1/3.r_{\mathrm{tri}}(B)=\left\lfloor\sqrt{B/3}\right\rfloor,\qquad r_{\mathrm{stack}}(B)\le B^{1/3}.

Proof. For tri-planes, the largest integer nn with 3n2≤B3n^2 \le B gives the sampling rate n=⌊B/3⌋n=\lfloor\sqrt{B/3}\rfloor. For a slice stack, Remark S1 requires r3≤Br^3 \le B, so r≤B1/3r \le B^{1/3}.

Sufficient detail. Under the same pixel budget, tri-planes show the three planes through the view center in finer detail than a slice stack, because their samples lie on these planes rather than on a 3D grid. Since every pixel lies on those planes, the pixel count of tri-planes scales quadratically with the sampling rate rr. By contrast, each zz-slice of a stack intersects the coronal and sagittal planes along a single line, so achieving rate rr on those planes requires at least rr slices of r×rr \times r pixels—most falling off the three planes. Thus, given BB pixels, the sampling rate scales as B\sqrt{B} for tri-planes versus at most B3\sqrt[3]{B} for a stack; for instance, 3⋅51223 \cdot512^2 pixels yield a rate of 512 for tri-planes but at most 92 for a stack. Alternatively, retaining 512×512512 \times512 slices under this budget permits only three slices, which can miss errors in the inter-slice gaps (Proposition S1, part (c)).

Near-Minimality of Tri-Planes

Among all layouts that sample the three planes through the view center, and not only slice stacks, tri-planes use nearly the fewest pixels. A sample near the line where two planes meet can cover points on both planes, whereas points far from these lines need different samples on each plane. Counting the samples that these separated regions need gives a lower bound for any layout.

Proposition S2 (Near-minimality). Any observation achieving sampling rate rr requires at least 3r2−12r3r^2 - 12r distinct sampling positions, and hence at least 3r2−12r3r^2 - 12r rendered pixels.

Proof. Set ρ=F/(2r)\rho= F/(2r). The coronal and sagittal planes intersect the axial plane A\mathcal{A} along the lines y=cyy = c_y and x=cxx = c_x, respectively. Removing a strip of half-width 2ρ2\rho around each of these lines leaves the region:

Afar={(x,y,cz)∈A:∣x−cx∣>2ρ, ∣y−cy∣>2ρ}.\mathcal{A}_{\mathrm{far}} = \{(x,y,c_z) \in\mathcal{A} : |x-c_x| > 2\rho,\ |y-c_y| > 2\rho\}.

Each excluded strip has width at most 4ρ4\rho and length FF. Subtracting the areas of both strips removes their overlap at the center twice, so it gives a lower bound on the remaining area:

area⁡(Afar)≥F2−8ρF.\operatorname{area}(\mathcal{A}_{\mathrm{far}}) \ge F^2 - 8\rho F.

We define the separated regions Cfar⊂C\mathcal{C}_{\mathrm{far}} \subset\mathcal{C} and Sfar⊂S\mathcal{S}_{\mathrm{far}} \subset\mathcal{S} of the other two planes in the same way.

No sample p∈Qp \in Q lies within ρ\rho of points in two different separated regions. For example, every point in Afar\mathcal{A}_{\mathrm{far}} has ∣y−cy∣>2ρ|y-c_y| > 2\rho and every point on C\mathcal{C} has y=cyy = c_y, so by the triangle inequality no sample lies within ρ\rho of both along the yy-axis. The same argument holds for every pair among Afar\mathcal{A}_{\mathrm{far}}, Cfar\mathcal{C}_{\mathrm{far}}, and Sfar\mathcal{S}_{\mathrm{far}}.

A sample covers an area of at most (2ρ)2=4ρ2(2\rho)^2 = 4\rho^2 on a target plane, so covering Afar\mathcal{A}_{\mathrm{far}} alone takes at least

area⁡(Afar)4ρ2≥F2−8ρF4ρ2=r2−4r\frac{\operatorname{area}(\mathcal{A}_{\mathrm{far}})}{4\rho^2} \ge\frac{F^2-8\rho F}{4\rho^2} = r^2 - 4r

distinct samples. Since no sample serves two of the three regions, summing over them gives:

∣Ω∣≥3(r2−4r)=3r2−12r.|\Omega| \ge3(r^2-4r) = 3r^2 - 12r.

Since tri-planes use 3r23r^2 pixels, no layout can save more than 12r12r pixels, i.e., a fraction of at most 4/r4/r, which goes to zero as rr grows. Equivalently, at a fixed pixel budget BB, no layout reaches a sampling rate above:

r≤2+B/3+4.r \le2 + \sqrt{B/3 + 4}.

At the budget of tri-planes with 512×512512 \times512 images (B=3×5122B = 3 \times512^2), the best possible layout reaches a sampling rate of at most 514.004, against 512 for tri-planes and at most 92.304 for a slice stack.

Anisotropic Voxel Spacing

The covering argument also applies to anisotropic sampling rates (rx,ry,rz)∈Z+3(r_x,r_y,r_z) \in\mathbb{Z}_+^3, which a scan needs when its voxel spacing differs between axes. An observation achieves sampling rates (rx,ry,rz)(r_x,r_y,r_z) if every target point u∈Πu \in\Pi has a sample p∈Ωp \in\Omega satisfying:

∣ux−px∣≤F2rx,∣uy−py∣≤F2ry,∣uz−pz∣≤F2rz.|u_x-p_x| \le\frac{F}{2r_x}, \qquad|u_y-p_y| \le\frac{F}{2r_y}, \qquad|u_z-p_z| \le\frac{F}{2r_z}.

Each sample then covers a box rather than a cube, and each plane is rendered on a rectangular grid.

Proposition S3 (Anisotropic sampling). Tri-planes achieve sampling rates (rx,ry,rz)(r_x,r_y,r_z) with rxry+rxrz+ryrzr_xr_y + r_xr_z + r_yr_z rendered pixels, whereas any parallel slice stack on a shared Cartesian grid requires at least rxryrzr_xr_yr_z pixels.

Proof. Uniform grids of rx×ryr_x \times r_y, rx×rzr_x \times r_z, and ry×rzr_y \times r_z samples on the axial, coronal, and sagittal planes meet the bound along each coordinate with rxry+rxrz+ryrzr_xr_y + r_xr_z + r_yr_z pixels. For a slice stack along zz, applying Lemma S1 along each axis shows that covering the coronal plane requires ∣X∣≥rx|X| \ge r_x and Ns≥rzN_s \ge r_z, and covering the sagittal plane requires ∣Y∣≥ry|Y| \ge r_y. The stack thus needs:

Ns∣X∣∣Y∣≥rzrxry.N_s|X||Y| \ge r_zr_xr_y.

Stacks along xx or yy follow by symmetry.

The lower bound of a slice stack exceeds the pixels of tri-planes by the factor:

rxryrzrxry+rxrz+ryrz=(1rx+1ry+1rz)−1≥min⁡(rx,ry,rz)3,\frac{r_xr_yr_z}{r_xr_y+r_xr_z+r_yr_z} = \left(\frac{1}{r_x}+\frac{1}{r_y}+\frac{1}{r_z}\right)^{-1} \ge\frac{\min(r_x,r_y,r_z)}{3},

which equals the isotropic factor r/3r/3 when rx=ry=rz=rr_x=r_y=r_z=r and exceeds 1, so that tri-planes save pixels, whenever 1/rx+1/ry+1/rz<11/r_x+1/r_y+1/r_z<1.

Agent Details

This section details the harness that § 3.3 summarizes, and § 18 gives the prompts of all MLLM calls (P1 to P10). Table S2 follows the steps of Figure 3 and lists what the agent does after each result. The three subsections follow the three parts of § 3.3: initialization (Sec. D.1), click selection from candidates (Sec. D.2), and multi-view verification with the acceptance rule and the call budget (Sec. D.3). Sec. E then gives the theory behind multi-view verification.

StepByResultNext
(b) Judge the viewMLLMAccept; Error with a box; Unsure; Wrong structure on the working, initial, or centroid view; Wrong structure on any other viewView passes; Step ①; Judge again; Stop; Judge again, as if unsure
① Check the boxHarnessOverlay covers less than 5% of an extra-part box or more than 50% of a missing-part box; OtherwiseView passes; Confirm the error
① Confirm the errorMLLMWithdrawn; Extra part covers at least 80% of a large cross-section of the prediction; Extra part covers less than 10% of the prediction’s cross-section on that plane; Three corrections already committed; OtherwiseView passes; Stop; View passes; Stop; Step ②
② Place candidatesHarnessNo valid candidate; Up to five points on the required side of the prediction boundary (Eq. (3))Judge again; Step ③
③ Pick a pointMLLMToo little budget left to pick a point and verify the corrected prediction; Declines to pick, or returns an invalid number; One pointStop; Judge again; Step ④
④ Check the proposalBothValid large correction that the remaining budget cannot verify; Rejected by the basic checks, the target check, or the before-and-after comparison; Passes all checksStop; Undo the click and return to ③ without this point; judge again once no point is left; Commit it and rebuild the views
(c) After the last viewHarnessEvery earlier click still holds; An earlier click no longer holdsAccept the prediction; Stop

Table S2. Outcomes of each step in Figure 3. Green marks a pass, and red (Stop) means that the agent stops without accepting the prediction. Each “Judge again” uses one of the two retries of the view, and the agent stops when no retry is left.

Initialization

Initial view. The harness centers the initial view on one component P0P_0 of the localization prior PP. Among the components that hold at least 10% of the voxels of the largest component, it takes the one with the highest average probability, so that a small but confident fragment cannot decide where the view goes. The view center c0c_0 is the deepest point of P0P_0, i.e., the voxel of P0P_0 with the largest distance dd to its boundary:

c0=arg⁡max⁡x∈P0d(x,∂P0).(6)c_0 = \arg\max_{x \in P_0} d(x, \partial P_0). \tag*{(6)}

Unlike the center of a bounding box, c0c_0 always lies inside P0P_0, even for a curved structure. The side length F0F_0 is the smallest of the presets 64, 128, and 256 mm at which P0P_0 fills at most 65% of the view along each axis. This fill is measured by the smallest box that is centered at c0c_0 and encloses P0P_0 (Figure S2 tests other fill values). When no preset is large enough, F0F_0 is 256 mm.

Ablation on the call budget and the initial view size

Figure S2. Ablation on the call budget and the initial view size. (a) Dice when the agent stops at each call budget, on the 598 ROIs where neither MLLM runs the ROI search; an ROI scores 0 when the budget runs out before the agent commits a prediction. Bands show 95% confidence intervals. (b) Initial view size with DeepSeek-V4.1-Flash. Prior fill: the largest share of the initial view that the localization prior may fill along each axis. A higher fill therefore allows a smaller view (Sec. D.1). Reruns: ROIs whose initial view changes at that fill; only these ROIs are run again. Mean Dice vs. default: the change in mean Dice from the default fill, with its 95% confidence interval. Other columns as in Table 3.

Initial prediction. On this view, fsegf_{\mathrm{seg}} produces two proposals: one grown from P0P_0, which fsegf_{\mathrm{seg}} receives as an initial segmentation, and one grown from a single point. For the point proposal, the harness tries up to five points, the first at c0c_0 and the other four inside the bounding box of P0P_0. It keeps the proposal with the highest Dice against P0P_0, without calling the MLLM. The MLLM then compares the two proposals on the same view in three sampled votes, each of which chooses one proposal or rejects both. It sees only the two proposals and not PP, so that a wrong prior cannot bias its choice. For organs, muscles, and vessels whose P0P_0 has at least 100 voxels, the selected proposal M~\widetilde{M} must also pass an overlap check with P0P_0:

∣M~∩P0∣min⁡(∣M~∣,∣P0∣)≥0.05.(7)\frac{\lvert\widetilde{M} \cap P_0\rvert}{\min(\lvert\widetilde{M}\rvert,\lvert P_0\rvert)} \ge0.05. \tag*{(7)}

Dividing by the smaller size lets a proposal larger than P0P_0 pass as long as it covers P0P_0. This check and the uncovered-prior view (Table S3) apply only to these three ROI types, because for the others a difference from P0P_0 does not mean that a proposal is wrong. For bones, flocf_{\mathrm{loc}} often localizes a neighboring vertebra, and tumors and lymph nodes are often thin or split into several pieces.

ViewLocationWhen used
WorkingLocation of the most recent positive click, or c0c_0Until a large correction has been committed
Negative clickLocation of the negative clickAfter a negative correction made during verification, until a large correction has been committed
InitialInitial view v0v_0Always
CentroidCentroid of the component of the prediction that contains the first clickUnless it lies within two voxels of the initial view
Last change / surfaceCentroid of the largest added or removed component, or the last click; before the first correction, the centroid of the largest cross-section of the prediction through a surface point, moved to the nearest voxel of the predictionUnless it lies within two voxels of an earlier verification view
Added and removed regionsSeparate views centered on the largest added and largest removed componentsWith five coverage views, after a change of that type
Separate pieceCentroid of an extra componentWith five coverage views, when such a component exists
Uncovered priorCentroid of the largest component of P0∖MtP_0 \setminus M_t, with the uncovered prior outlined in blueOrgans, muscles, and vessels, when at least 30% of P0P_0 is uncovered and this component contains at least 100 voxels
OverviewCentroid of the whole prediction, using the next larger preset side lengthWhen a larger preset is available

Table S3. Views that the agent judges. The first two come before verification, and the others are verification views.

The selected proposal becomes M0M_0 once it passes the checks in Sec. D.2. When the MLLM selects the proposal from P0P_0 but this proposal fails the checks, three sampled votes choose among the sampled points themselves, drawn as numbered rings on the tri-planes of v0v_0. The MLLM sees only the points, not their proposals, and the proposal from the chosen point then goes through the same checks. When the votes reject both proposals, the harness moves to a view with another preset side length. Initialization tries at most six proposals, and if none of them is committed, the agent continues with the ROI search below.

ROI search without a localization prior. The ROI search runs when flocf_{\mathrm{loc}} finds nothing or when initialization ends without a committed prediction, so that a failed localization does not end the annotation. It restarts the loop with an empty prediction and a new call budget and does not use PP. The MLLM first places a rough point on the target in 16 axial slices that span the whole scan, and then refines this point in 16 axial slices within a 96 mm window around it. On a 128 mm view centered at the refined point, the MLLM places the first positive click directly, without candidates. The proposal from this click must pass the checks in Sec. D.2; when it fails, the MLLM places another click on the same view, within the limit of six trials. The loop then continues from the committed prediction. If the MLLM finds no target in the whole-scan slices, or no proposal is committed within the six trials, the agent stops without accepting a prediction.

Click Selection from Candidates

Confirming an error (step ❶). For a box that the overlay does not contradict (the box check in Table S2), the harness renders a view centered on the box, with a crosshair and the measured size of the boxed region (P4). The MLLM must name the tissue at the crosshair before it confirms or withdraws the error, and the prompt tells it to withdraw when in doubt. The agent therefore edits only errors that the MLLM can confirm.

Checking a proposal (step ❹). The harness commits a proposal only after it passes the basic checks and the MLLM confirms it. The basic checks reject bad proposals, e.g., a proposal that is empty, leaves the prediction unchanged, breaks a current or past click, or covers more than 20% of the volume. The MLLM then confirms, with at least medium confidence, that the proposal lies on the correct target. We call a correction large when it changes more than 20% of the union of the two predictions. A correction is also large when it adds or removes a piece that holds at least 5% of the changed voxels and has its centroid at least F0/2F_0/2 from c0c_0 along an axis. For a large correction, the MLLM also compares the predictions before and after the click and checks that the click fixes the marked error without spreading into wrong regions.

Multi-View Verification

Verification views. Table S3 lists the views that the agent checks, which depend on the current prediction, the initialization, and the interaction history. Verification normally uses three coverage views (initial, centroid, and last change or surface), and five coverage views after a large correction or when the prediction has an extra component that is far away, small, or large. An extra component is a 6-connected component that does not contain the first click. It is far away when its centroid lies at least F0/2F_0/2 from c0c_0 along an axis, small when it has fewer than 10% of the voxels of the largest component, and large when it holds at least 5% of the voxels of the prediction. In both this rule and the rule for a large correction, F0F_0 and c0c_0 belong to the first initial view and stay fixed even when initialization moves to another preset; after the ROI search, c0c_0 is the searched location and F0=128F_0 = 128 mm.

The uncovered-prior and overview views are added to the coverage views, and a view that lands within two voxels of an earlier verification view is dropped, since it would repeat that check. When a correction is committed, the agent rebuilds the views and keeps only the verdicts of initial and centroid views whose images did not change, so that every decision concerns the latest prediction. A “wrong-structure” verdict stops the agent only on the working, initial, and centroid views, since these views show the target structure best. The uncovered-prior view checks only whether the outlined tissue belongs to the target, and it rejects nothing by itself.

Acceptance rule. The MLLM judges the views of V(Mt)\mathcal{V}(M_t) one at a time in a fixed order. The first view in which the MLLM confirms an error starts a correction at once, and the later views are not judged on MtM_t. The MLLM confirms an error when it marks the error with a box and keeps the box through the box check and the confirmation view (Table S2). After a small correction, the MLLM first judges the working view once more, or the negative-click view if the correction was negative and made during verification; the harness then rebuilds the views. After a large correction, the harness rebuilds the views at once. Let χt=1\chi_t = 1 if every view in V(Mt)\mathcal{V}(M_t) has passed on MtM_t, counting the verdicts kept for the initial and centroid views, and χt=0\chi_t = 0 otherwise. Let Kt+\mathcal{K}_t^+ and Kt−\mathcal{K}_t^- denote the voxel positions of the positive and negative clicks up to step tt. The agent accepts the prediction at the first step TaccT_{\mathrm{acc}} at which every verification view passes and no later click has undone an earlier one:

Tacc=min⁡{t:χt=1, Kt+⊆Mt, Kt−∩Mt=∅}.(8)T_{\mathrm{acc}} = \min\left\{t : \chi_t = 1,\ \mathcal{K}_t^+ \subseteq M_t,\ \mathcal{K}_t^- \cap M_t = \varnothing\right\}. \tag*{(8)}

The two click conditions require every positive click to stay inside the prediction and every negative click to stay outside it. If Tacc<∞T_{\mathrm{acc}} < \infty, the agent stops at T=TaccT = T_{\mathrm{acc}} and outputs M=MTM = M_T; otherwise, it stops without accepting the prediction in one of the cases of Table S2.

Views after a correction. By Remark 1, a new error region after a correction must intersect the region Δt\Delta_t that the correction changes, which can be large, split into several pieces, or far from the click. The harness centers the last-change view on the largest added or removed piece of Δt\Delta_t. After a large correction, it adds separate views on the largest added and the largest removed pieces, and the MLLM compares the predictions before and after the click (Sec. D.2). The smaller pieces of Δt\Delta_t are checked wherever the planes of other views pass through them. Likewise, an error region created by an earlier click intersects the change made by that click, and the next round centers views on this change. If that round stops earlier at an error in another view, later rounds check this change wherever their views pass through it. A view whose planes miss Δt\Delta_t has the same tri-planes after the correction, so its earlier verdict still applies. The harness keeps such verdicts only for the initial and centroid views whose images did not change. The MLLM judges the other rebuilt views again, since their centers depend on the updated prediction.

Call budget and stopping. Each run of the loop (including the rerun for the ROI search) allows up to 26 MLLM calls and three committed corrections (Figure S2 tests other budget limits). Since the rerun starts with a new budget, an ROI that goes to the ROI search can use more than 26 MLLM calls in total. Before each click, the harness reserves enough of this budget to verify the resulting prediction, so the agent stops with the current prediction instead of committing a correction that it cannot verify. Whenever the agent stops without accepting the prediction, it records the reason and any views it could not confirm, and it outputs the current prediction when one exists.

Theory of Multi-View Verification

This section gives the theory behind multi-view verification (§ 3.3); as in Sec. C, the symbols that the proofs define are local to them.

Where New Error Regions Can Appear

We prove Remark 1. A voxel is wrong in a prediction MM when MM and M∗M^* disagree on it. Let d(x,∂M∗)d(x,\partial M^*) denote the distance from a voxel xx to the boundary of M∗M^*, and let E(M)E(M) denote the wrong voxels of MM that lie farther than a distance τ\tau from this boundary:

E(M)={x∈M△M∗:d(x,∂M∗)>τ}.E(M) = \{x \in M \triangle M^* : d(x,\partial M^*) > \tau\}.

An error region of MM is a connected component of E(M)E(M) under 26-connectivity whose volume is at least a fraction γ\gamma of the volume of M∗M^*. The set Δt=Mt+1△Mt\Delta_t = M_{t+1} \triangle M_t holds the voxels that step tt changes, and it is empty unless step tt commits a click.

Proof. A voxel outside Δt\Delta_t lies either in both MtM_t and Mt+1M_{t+1} or in neither, so it is wrong in Mt+1M_{t+1} exactly when it is wrong in MtM_t. Its distance to the boundary of M∗M^* does not depend on the prediction, so E(Mt+1)E(M_{t+1}) and E(Mt)E(M_t) contain the same voxels outside Δt\Delta_t. Let CC be an error region of Mt+1M_{t+1} that does not intersect Δt\Delta_t. Then C⊆E(Mt)C \subseteq E(M_t), and since CC is connected, it lies inside one connected component C′C' of E(Mt)E(M_t). The volume of C′C' is at least that of CC, hence at least a fraction γ\gamma of the volume of M∗M^*, so C′C' is an error region of MtM_t that contains CC. For the second part, the renderer RR draws each of the tri-planes of a view from VV and from the cross-section of the prediction on that plane. The volume VV stays fixed, and Mt+1M_{t+1} and MtM_t agree on every plane that contains no voxel of Δt\Delta_t. For any view vv whose three planes miss Δt\Delta_t, the harness therefore renders the same three images for MtM_t and Mt+1M_{t+1}, i.e., R(V,Mt+1;v)=R(V,Mt;v)R(V,M_{t+1};v) = R(V,M_t;v).

Views Centered at a Centroid

The last-change view and most other verification views are centered at the centroid of a connected component, such as a piece of the prediction or the largest region that the last click changed. The lemma below shows that such a view always cuts its component, so the harness can use the raw centroid without moving it onto the prediction.

Lemma S2 (Planes through a centroid.) For a view centered at the centroid of a connected component, each of its three planes passes through that component, even when the center lies outside it.

Proof. Let Γ\Gamma be a connected component of a voxel set, under any connectivity in which neighboring voxels differ by at most one layer along each axis, such as 6-, 18-, or 26-connectivity. We treat the axial axis; the coronal and sagittal axes follow in the same way. Let z(w)z(w) denote the axial layer of a voxel ww, and let zmin⁡z_{\min} and zmax⁡z_{\max} be the first and last layers that Γ\Gamma occupies. Since Γ\Gamma is connected, a chain of neighboring voxels in Γ\Gamma leads from a voxel in layer zmin⁡z_{\min} to a voxel in layer zmax⁡z_{\max}. The layer changes by at most one from each voxel of the chain to the next, so the chain passes through every layer in between, and Γ\Gamma occupies every layer from zmin⁡z_{\min} to zmax⁡z_{\max}. The axial coordinate of the centroid,

zˉ=1∣Γ∣∑w∈Γz(w),\bar{z} = \frac{1}{|\Gamma|} \sum_{w \in\Gamma} z(w),

is an average of values in [zmin⁡,zmax⁡][z_{\min}, z_{\max}], so it lies in this interval as well. The renderer places the axial plane at the layer nearest to zˉ\bar{z}, which lies between ⌊zˉ⌋\lfloor\bar{z} \rfloor and ⌈zˉ⌉\lceil\bar{z} \rceil; both lie in [zmin⁡,zmax⁡][z_{\min}, z_{\max}] because zmin⁡z_{\min} and zmax⁡z_{\max} are integers. The axial plane therefore lies in a layer that Γ\Gamma occupies, so it meets Γ\Gamma.

The center itself need not lie in Γ\Gamma: for a ring-shaped or curved component, the centroid can fall in the hole while each plane still cuts the ring. The guarantee concerns the planes in 3D, not the cropped images. When Γ\Gamma extends beyond the view, its voxels on a plane can lie outside the rendered image, so the lemma does not imply that Γ\Gamma appears in every image of the tri-planes. The lemma covers the centroid, last-change, added- and removed-region, separate-piece, and uncovered-prior views. The overview view falls outside it, since its center is the centroid of the whole prediction and can lie between its pieces. The surface view is moved to the nearest voxel of the prediction, and the initial view is centered at the deepest point of P0P_0, so their planes meet the prediction and P0P_0, respectively, by construction.

Chance of Missing an Error Region

We bound the chance that several views all miss the error regions of a prediction, because an error region can lie off the planes of every view that passes. The harness chooses its views by fixed rules, so this chance comes from what the agent does not know: we treat the ground-truth mask M∗M^* as random given the history H\mathcal{H} of everything that the agent has observed. A view shows an error region when one of its three images contains a voxel of this region at the image resolution, whether or not the MLLM notices it; the judgment of the MLLM enters in Corollary S2.

Proposition S4 (Chance of missing an error region). Let the current prediction contain an error region, and suppose that at least kk of the views judged on it each show an error region with probability at least pcov∈(0,1]p_{\mathrm{cov}} \in(0,1], given H\mathcal{H} and given that the views before it showed none. Then all views judged on it miss the error regions with probability at most (1−pcov)k(1-p_{\mathrm{cov}})^k.

Proof. Let JJ be the number of views, and let AjA_j be the event that none of the first jj views shows an error region, with A0A_0 certain. Each factor Pr⁡(Aj∣Aj−1,H)\Pr(A_j \mid A_{j-1}, \mathcal{H}) is at most 1, and by assumption it is at most 1−pcov1-p_{\mathrm{cov}} for at least kk of the views, so the chain rule gives:

Pr⁡(AJ∣H)=∏j=1JPr⁡(Aj∣Aj−1,H)≤(1−pcov)k.\Pr(A_J \mid\mathcal{H}) = \prod_{j=1}^{J} \Pr(A_j \mid A_{j-1}, \mathcal{H}) \le(1-p_{\mathrm{cov}})^k.

The condition asks each of these kk views to keep a chance of showing an error region after the earlier views have missed it. More views alone do not meet the condition, since views close to each other can leave the same region unseen. A view with the same images as a view that the MLLM has already judged, including a view whose verdict the harness keeps from an earlier round, adds no new chance and does not count toward kk. The harness therefore spreads its views over different parts of the prediction, the change, and the prior. § 15.§ 3 measures pcovp_{\mathrm{cov}} for the views of our harness.

Outcome and Cost of an Idealized Run

We count judgments of views, i.e., MLLM calls that judge the working view or a verification view, and let KK be the largest number of views in V(Mt)\mathcal{V}(M_t). Let R1,…,RNerrR_1,\ldots,R_{N_{\mathrm{err}}} denote the error regions of M0M_0 (Sec. E.1). Since M∗M^* is random given the history (Sec. E.3), so is NerrN_{\mathrm{err}}. We consider an idealized run that no rule ends early, i.e., we ignore the call budget, the cap of three corrections, and the other stops without acceptance in Table S2. Corollary 1 in the main paper states the first part of the corollary below.

Corollary S2 (Reaching a prediction without error regions). Assume that (A1) the MLLM judges every view correctly, i.e., it confirms an error in a view exactly when the view shows an error region, and it is never unsure; (A2) in every round, at least kk of the verification views meet the condition of Proposition S4 for a lower bound pcovp_{\mathrm{cov}} that holds in all rounds; and (A3) each error that the MLLM confirms leads to a committed correction after which every error region lies inside an error region of

the prediction before it, and at least one of R1,…,RNerrR_1,\ldots,R_{N_{\mathrm{err}}} that contained an error region before the correction contains none after it. In an idealized run, the agent then accepts a prediction without error regions within NerrN_{\mathrm{err}} corrections with probability at least 1−E[Nerr](1−pcov)k1-\mathbb{E}[N_{\mathrm{err}}](1-p_{\mathrm{cov}})^k, and the run makes at most (Nerr+1)(K+1)(N_{\mathrm{err}}+1)(K+1) judgments in every case.

Proof. We call the judgments between two consecutive corrections a round, and likewise the judgments before the first correction and after the last one. By (A1), a round on a prediction with error regions ends in a correction when one of its views shows an error region, and in a wrong acceptance otherwise; by Proposition S4 and (A2), the second case has probability at most (1−pcov)k(1-p_{\mathrm{cov}})^k. By (A3), every error region after a correction lies inside an error region before it. Since R1,…,RNerrR_1,\ldots,R_{N_{\mathrm{err}}} are disjoint, induction shows that every error region of a later prediction lies inside one of them and that a region RiR_i without error regions never gets one back. Every correction clears at least one more RiR_i, so at most NerrN_{\mathrm{err}} rounds see a prediction with error regions. Given the history before it, each of these rounds ends in a wrong acceptance with probability at most (1−pcov)k(1-p_{\mathrm{cov}})^k, so summing over the rounds bounds the chance of a wrong acceptance by (1−pcov)k(1-p_{\mathrm{cov}})^k times the expected number of these rounds, which is at most E[Nerr]\mathbb{E}[N_{\mathrm{err}}]. Without a wrong acceptance, every RiR_i is cleared, so no error region remains, and every view of the last round passes by (A1). The click conditions of Eq. (8) also hold, since the basic checks keep every earlier click on its side of each committed prediction (Sec. D.2). The agent therefore accepts a prediction without error regions. For the cost, each round starts with at most one judgment of the working view, namely the first judgment of the run or the re-check after a small correction, and then judges at most KK verification views, since the first error that the MLLM confirms ends it. The run has at most Nerr+1N_{\mathrm{err}}+1 rounds, so it makes at most (Nerr+1)(K+1)(N_{\mathrm{err}}+1)(K+1) judgments.

With pcov=1p_{\mathrm{cov}}=1, i.e., when the views of every round show a remaining error region, the agent accepts a prediction without error regions with certainty, which is the deterministic case. In our harness, K≤7K\leq7, because a round checks at most five coverage views plus the uncovered-prior and overview views. An idealized run therefore makes at most 8(Nerr+1)8(N_{\mathrm{err}}+1) judgments, regardless of the size of the target. Besides these judgments, each correction needs a bounded number of other decisions: confirming the error, picking a candidate, and checking the proposal. The total number of decisions is thus also at most linear in NerrN_{\mathrm{err}}. A real run may stop without accepting a prediction if fixing its error regions takes more than the budget of 26 MLLM calls or the cap of three corrections (Sec. D.3). We expect this case to be rare, since most ROIs finish within about ten calls (Figure S2).

When the assumptions fail. If (A1) or (A3) fails, a run can go two ways. It can cost more: an unsure verdict costs up to two retries, a rejected proposal leads to further candidates and a new judgment of the view, and a correction that fixes nothing adds a round. It can also end too early with a wrong prediction, when no view shows a remaining error region or the MLLM misses one that a view shows. Suppose that, given the history, the MLLM confirms an error in a view that shows an error region with probability at least s∈[0,1]s\in[0,1], every error that it confirms lies in an error region, and the correction that follows breaks (A3) with probability at most η\eta. The argument of Corollary S2 then gives:

Pr⁡(the agent accepts a prediction without error regions)≥1−E[Nerr][(1−spcov)k+η].\Pr(\text{the agent accepts a prediction without error regions}) \geq1-\mathbb{E}[N_{\mathrm{err}}]\left[(1-sp_{\mathrm{cov}})^k+\eta\right].

More views that meet the condition of Proposition S4 shrink the first term, and a segmentation model that keeps earlier corrections keeps the second term small. The false accepts in our experiments count the runs that end too early with a clearly wrong prediction (Table 3).

Benchmark Composition

Design principles. Our benchmark favors breadth: many ROI types, datasets, and imaging modalities, with a few cases from each source. We sample at most 15 cases from each dataset and keep every valid ROI that appears in the volume within a reasonable field of view. CVPR-BiomedSegFM [76] splits SegRap2023 into a contrast-enhanced subset (14 volumes) and a non-contrast subset (10 volumes), so this limit applies to each subset. To cover more anatomical structures and scanner protocols, we also include held-out cases from datasets used to train flocf_{\mathrm{loc}} or fsegf_{\mathrm{seg}}.

Training exposure groups. We group the dataset families by which of flocf_{\mathrm{loc}} and fsegf_{\mathrm{seg}} have seen them in training. The localization model flocf_{\mathrm{loc}} was trained on the text-guided training split of CVPR-BiomedSegFM [76], which spans 68 datasets (24 CT, 28 MR, 1 PET, 4 ultrasound, and 11 microscopy). For fsegf_{\mathrm{seg}}, we use the training and held-out lists in Tables A1 and A2 of [47], which name 120 training datasets. The two conditions give four exposure groups: C1 (both), C2 (fsegf_{\mathrm{seg}} only), C3 (flocf_{\mathrm{loc}} only), and C4 (neither). For the four lesion datasets in C4 (MSWAL, DOHIID, Pituitary-MRI, and UT-EndoMRI), we also checked that no training dataset of fsegf_{\mathrm{seg}} annotates the same lesion types.

Benchmark statistics. The benchmark starts from 706 candidate ROIs in 262 volumes from 35 datasets. We exclude 16 of the 87 ROIs from TotalSegmentator MRI because their ground-truth masks are unusable (left and right labels swapped, or the ROI cut off by the field of view). This exclusion leaves 690 ROIs for evaluation (Figure S1 and Table S4). By training exposure, they split into C1 (288), C2 (45), C3 (192), and C4 (165); by modality, into CT (368), MR (319), and PET (3); by size, into 260 small and 430 large; and by ROI type, into 398 organs, 222 lesions, 34 vessels, 10 bones, 15 lymph nodes, and 11 muscles.

Figure S1. Distribution of the evaluated ROIs in the benchmark. Inner ring: ROI types; outer ring: the ROIs of each type, with left and right counterparts merged and ROIs with fewer than 10 instances grouped as “other”. IVC: inferior vena cava; GTVp + GTVn: primary and nodal gross tumor volume.

GroupSourceMod.RegionAnnotated ROIsVol.ROIs
C1AMOS [49]CTabdomenabdominal organs and vessels344
C1AMOS-MRI [49]MRabdomenabdominal organs and vessels339
C1AbdomenAtlas [61]CTabdomenabdominal organs and vessels334
C1TotalSegmentator MRI [4]MRwhole bodyorgans, muscles, bones, vessels371
C1CHAOS [53]MRabdomenliver, kidneys, spleen (T1, T2)416
C1BraTS [14, 15, 52, 79]MRbrainglioma subregions (T1n, T1c, T2w, T2f)1241
C1crossMoDA [26]MRbrainvestibular schwannoma, cochlea312
C1WMH [55]MRbrainwhite matter hyperintensities33
C1ACDC [16]MRheartLV, RV, myocardium35
C1MSD Heart [8]MRheartleft atrium22
C1ATM’22 [121]CTthoraxairway tree33
C1AVT [90]CTthorax–abdomenaortic vessel tree33
C1COVID-19-20 [94]CTthoraxCOVID-19 lesions33
C1COVID-19-CT-Seg [72]CTthoraxCOVID-19 lesions11
C1NSCLC-Radiomics [2]CTthoraxleft, right lung12
C1NCI-ISBI 2013 [17]MRpelvisprostate (whole gland)33
C1MSD Prostate / PROSTATEx [8, 10]MRpelvisprostate (whole gland)33
C1autoPET [35]PETwhole bodyFDG-avid lesions33
C2WORD [70]CTabdomenliver, pancreas, spleen1545
C3HaN-Seg [88]CThead & neckorgans at risk4116
C3SegRap2023 [71]CThead & neckprimary GTV (contrast, non-contrast)2424
C3HNTS-MRG 2024 [102]MRhead & neckprimary and nodal GTV (T2)1515
C3LNQ 2023 [27, 45]CTthoraxmediastinal lymph nodes1515
C3LCTSC [115]CTthoraxthoracic organs at risk315
C3Adrenal-ACC-Ki67 [3, 80]CTabdomenadrenocortical carcinoma33
C3ISLES 2022 [40]MRbrainischemic stroke lesions33
C3QIN-PROSTATE [32]MRpelvisprostate11
C4MS-CMRSeg [34, 112, 128]MRheartLV, RV, myocardium (LGE)1545
C4RHUH-GBM [21]MRbrainenhancing tumor, whole tumor1530
C4CRLM [98]CTabdomencolorectal liver metastases1515
C4RIDER Lung CT [109, 122]CTthoraxprimary lung tumor (GTV)1515
C4MSWAL [113]CTabdomengallstones, kidney stones1515
C4DOLCHID [44]CTjawodontogenic lesions1515
C4Pituitary-MRI [87]MRsellar regionpituitary neuroendocrine tumor1515
C4UT-EndoMRI [63]MRpelvisendometriomas, pelvic cysts1515
Total: 35 sources; CT 368, MR 319, PET 3262690

Table S4. Data sources of the benchmark. The sources are grouped by which of flocf_{\mathrm{loc}} and fsegf_{\mathrm{seg}} have seen them in training: C1, both (288 ROIs); C2, fsegf_{\mathrm{seg}} only (45); C3, flocf_{\mathrm{loc}} only (192); and C4, neither (165). Vol.: volumes. For MSD Prostate / PROSTATEx, CVPR-BiomedSegFM [76] releases the masks under the class name “transition zone”, but they cover the whole gland.

Data splits and leakage audit. For any dataset that either model trained on, we sample only from its validation or test cases, whereas datasets absent from both training lists (e.g., RHUH-GBM and CRLM) may contribute cases from any split. We take the datasets of C1 and C3 from CVPR-BiomedSegFM, drawing from its 3D validation split (held out from flocf_{\mathrm{loc}} training by task filename) and excluding all FLARE22 training cases [74]. We take the datasets of C2 and C4 from their original public releases, including the collections of The Cancer Imaging Archive [22]. We also remove every volume or series from any patient whose scans appear in the public training records of either model. We exclude HCC-TACE entirely, since it has no independent official validation or test split and six of its candidate cases overlap with the training set of flocf_{\mathrm{loc}}.

Prompt formulation. The prompt of the agent follows the template {target} in {region} {modality}. For flocf_{\mathrm{loc}}, we follow its own prompt convention: CVPR-BiomedSegFM ROIs use the training prompt of their dataset, other ROIs of a known class use the first training prompt of this class, and ROIs without a matching class use the template of the agent (e.g., odontogenic lesions in DOLCHID [44]).

Morphological complexity. For the shape analysis of multi-view verification (Sec. 1.3), we measure two quantities of each ground-truth ROI M∗M^{*}: its physical volume Vol⁡(M∗)\operatorname{Vol}(M^{*}) and its surface area Area⁡(∂M∗)\operatorname{Area}(\partial M^{*}), counted on voxel faces. We rank ROIs by their sphericity ψ=π1/3[6Vol⁡(M∗)]2/3/Area⁡(∂M∗)\psi= \pi^{1/3}[6\operatorname{Vol}(M^{*})]^{2/3}/\operatorname{Area}(\partial M^{*}), which divides the surface area of a sphere with the same volume by the surface area of the ROI. The sphericity ψ\psi equals 1 for a sphere and decreases as the ROI becomes more elongated, hollow, or fragmented. We call an ROI complex when ψ<0.386\psi< 0.386 and compact otherwise, a threshold that depends only on the ground-truth shapes: it marks about the least spherical third of the 630 ROIs outside the four C4 lesion datasets, which follow the same threshold. Of all 690 ROIs, 203 are complex; of the 190-ROI subset, 58 are complex and 132 compact. Complex ROIs are mostly tubular, ring-shaped, or branching structures (e.g., aorta, myocardium, and airway), whereas compact ROIs are rounder structures (e.g., liver, spleen, and lymph nodes). The two groups have similar median equivalent spherical diameters (4.2 and 4.3 cm), so the split separates shape rather than size.

Development set. We developed prompts and thresholds on a pool of cases from the validation and test splits of TotalSegmentator v2 [108], unused CVPR-BiomedSegFM validation cases, WORD, MS-CMRSeg, RHUH-GBM, and FLARE22. From this pool, we fixed a development set of 74 ROIs (Table S5): 29 for quick iteration and 45 more for wider coverage. The development pool shares no cases with the benchmark, and for CVPR-BiomedSegFM sources it shares no subjects either. Table S10 reports separately the C4 datasets that the pool does not include.

SourceModalityROIsOrganMuscleVesselBoneLesionLymph nodeSmallLarge
TotalSegmentator v2CT342224600430
CVPR-BiomedSegFM (27 datasets)CT 11, MR 15, PET 12711012121720
FLARE22CT440000004
WORDCT330000003
MS-CMRSegMR440000004
RHUH-GBMMR200002011
Development setCT 52, MR 21, PET 174442581411262
BenchmarkCT 368, MR 319, PET 369039811341022215260430

Table S5. Composition of the 74-ROI development set and of the benchmark. ROI types and sizes follow § 4.1.

MethodMLLMAllSeenUnseenC4Not used in development
flocf_{\mathrm{loc}} [123]–66.975.247.835.713.0
floc→fsegf_{\mathrm{loc}}\rightarrow f_{\mathrm{seg}}–65.672.250.739.716.1
TriSegAgentClaude-Sonnet-5.563.267.653.243.025.2
TriSegAgentGPT-5.6-Sol64.265.561.354.039.2
TriSegAgentDeepSeek-V4.1-Flash64.769.055.045.324.1
TriSegAgentQwen3.8-Flash64.968.157.548.628.6
TriSegAgentGemini-3.8-Flash66.366.466.159.246.6
TriSegAgentGPT-6.1-Sol68.868.2<u>70.2</u><u>64.4</u><u>53.3</u>
TriSegAgentClaude-Opus-5.5<u>69.2</u>70.765.658.745.6
TriSegAgentGPT-6-Astra70.0<u>69.3</u>71.566.257.2

Table S10. Performance on the seen and unseen datasets of flocf_{\mathrm{loc}} (690 ROIs). Seen and Unseen: ROIs from the seen (480) and unseen (210) datasets of flocf_{\mathrm{loc}}; C4: datasets unseen by both flocf_{\mathrm{loc}} and fsegf_{\mathrm{seg}} (165); Not used in development: the C4 datasets that we never used while developing TriSegAgent (90). flocf_{\mathrm{loc}} and floc→fsegf_{\mathrm{loc}}\rightarrow f_{\mathrm{seg}} (Figure 6) are shown as references; the best and second-best results of TriSegAgent are bolded and underlined.

Ablation subset. To limit the API cost, we run the ablations on a 190-ROI subset that covers every kind of ROI in the benchmark. From the 630 ROIs outside the four C4 lesion datasets (MSWAL, DOLCHID, Pituitary-MRI, and UT-EndoMRI), the subset includes at least one ROI for each ROI name in each dataset. It also includes four ROIs from each of the four lesion datasets. Of the 190 ROIs, 69 have an equivalent diameter below 3 cm. As with TriSegAgent in Table 1, every run falls back to the ROI search without a prior when flocf_{\mathrm{loc}} returns an empty prediction (Sec. D.1), and an ROI without a final prediction scores 0.

Experimental Setup

This section gives the configuration of the MLLMs, of nnInteractive Agent, and of the other models in our experiments.

MLLMs. Unless noted otherwise, TriSegAgent runs every MLLM with the same prompts at its default reasoning effort; only Tab. S16 uses other effort levels. Among these MLLMs, DeepSeek-V4.1-Flash and Qwen3.8-Flash are open-weight models. All runs of DeepSeek-V4.1-Flash use its 1017 version.

nnInteractive Agent. We run nnInteractive Agent [48] from its public repository at commit 57b06cb, using its unguided track and the public nnInteractive v1.0 weights. GPT-6.1-Sol and GPT-5.6-Sol run in Codex CLI 0.160.0 [83] and Claude-Sonnet-5.5 runs in Claude Code 2.1.314 [5], all at medium reasoning effort. Each ROI runs alone in a bubblewrap sandbox, with a limit of 20 minutes and no limit on model calls, so that the agent can use as many turns as it needs within that time. For Table 2, nnInteractive Agent with GPT-5.6-Sol also runs on the 190-ROI subset with the localization prior: it receives the same cached mask of flocf_{\mathrm{loc}} that TriSegAgent starts from, is told that the mask may be wrong, and may load, correct, or discard it; all other settings stay the same. Three of these runs reach the time limit and four end without a mask, and all seven score 0.

Other models. BiomedParse v2 [123, 124], nnInteractive [47], the five end-to-end segmentation models, and MedSAM-Agent [68] all run from their public weights. The oracle of Table 1 starts from an empty prediction and simulates its clicks from the largest connected component of the ground-truth mask. The ablations use two more models: SAT-Nano [125] (Table S7) at commit 5676be5 with its public Nano weights, and MedSAM2 [75] (Table S17) at commit 332f30d with the public MedSAM2_latest weights.

MLLMPriorAll (190)Seen (159)Unseen (31)Small (69)Large (121)FA↓
DeepSeek-V4.1-FlashNone25.423.734.212.832.665
DeepSeek-V4.1-FlashSAT-Nano32.831.837.914.143.571
DeepSeek-V4.1-FlashBiomedParse63.868.241.043.075.723
Gemini-3.8-FlashNone44.242.850.822.656.529
Gemini-3.8-FlashSAT-Nano41.438.257.922.252.338
Gemini-3.8-FlashBiomedParse65.867.557.249.375.312

Table S7. Ablation on the localization prior. Every run uses the ROI search fallback. Seen and Unseen: the seen and unseen datasets of flocf_{\mathrm{loc}} (Figure 6). ROIs that ended in a runtime error were run again once; 7 ROIs with SAT-Nano and DeepSeek-V4.1-Flash still failed and are scored as they stand.

fsegf_{\mathrm{seg}}MeanMedianSmallLargeFA↓\downarrow
MedSAM2 [75]61.674.539.174.518
nnInteractive [47]63.879.143.075.723

Table S17. Ablation on the interactive segmentation model fsegf_{\mathrm{seg}}. TriSegAgent runs with DeepSeek-V4.1-Flash, the same prompts, and the ROI search fallback. Columns as in Table 3.

Coding-Agent Evaluation

This section gives the evaluation details of Codex in Table 2, where Codex runs on the 190-ROI subset of Sec. F.

Observation conditions. Codex annotates each ROI under four conditions, which differ in what Codex sees and in whether its initial view comes from the localization prior. In the volume condition, Codex reads the raw 3D volume with its own code, whereas in the axial and tri-planar conditions it sees rendered images of one axial slice or of tri-planes. The fourth condition adds the localization prior to the tri-planar condition: its initial view comes from the prior and has the same center and side length as the initial view of TriSegAgent. Without the prior, the initial view shows the whole scan.

Agent setup and access to fsegf_{\mathrm{seg}}. We run Codex CLI 0.160.0 [83] with GPT-6.1-Sol [85] at medium reasoning effort. For each ROI, a new session starts in an isolated sandbox that contains neither our code nor the ground-truth masks. The task description gives Codex the target name and annotation guidelines that TriSegAgent receives, and it states the scoring metric. Codex controls the same fsegf_{\mathrm{seg}} through a command-line tool: it places one positive or negative click at a time, gets the 3D prediction, and accepts or rejects it before the next click. In the image-based conditions, it can also ask for a new view with another center or side length. Each ROI allows up to 20 clicks, 60 views, and 20 minutes.

Scoring and audit of the sessions. We score the final accepted prediction by 3D Dice over the whole volume, and we use the ground-truth masks only for this score. An ROI scores 0 when Codex submits no prediction. We checked every shell command that Codex ran: none made an external network call or tried to leave the sandbox.

Extended Experiment Results

This section extends the experiments of the main paper. Unless noted otherwise, they use the 190-ROI subset of Sec. F, and the tables report Dice (%) and bold the best result of each MLLM. Small, Large, and FA follow § 4.1. Table 1 leaves out TriSegAgent with Qwen3.8-Flash for space, so Table S6 gives its results on all 690 ROIs in the same columns.

MLLMOverall MeanOverall MedianOrganMuscleVesselBoneLesionLymph nodeSmallLarge
Qwen3.8-Flash [89]64.9 (2.4)78.073.177.769.326.551.650.247.875.2

Table S6. Performance of TriSegAgent with Qwen3.8-Flash on the benchmark (690 ROIs). Columns as in Table 1.

Localization and Generalization

PointAll (190)Seen (159)Unseen (31)Small (69)Large (121)
DeepSeek-V4.1-Flash ROI search3332391742
Gemini-3.8-Flash ROI search5957743374
SAT-Nano view center343432948
BiomedParse view center8391456593

Table S8. Localization accuracy of the prior and of the ROI search. Each entry is the share of ROIs (%) whose point falls inside the ground truth. This point is either the first view center from flocf_{\mathrm{loc}} or the last point of the MLLM’s whole-scan ROI search. A search without a point counts as a miss. Seen and Unseen are as in Table S7. The best share in each column is in bold.

Localization prior and ROI search. The localization prior gives TriSegAgent its starting point, and the ROI search recovers some of the targets that the localization misses (Table S7 and S8). The prior helps most on small targets, which appear on only a few of the hundreds of slices, and on the seen datasets of flocf_{\mathrm{loc}}: on both, flocf_{\mathrm{loc}} places the initial view center inside the target far more often than the ROI search does. On the unseen datasets of flocf_{\mathrm{loc}}, the ROI search of Gemini-3.8-Flash places more points inside the target than flocf_{\mathrm{loc}}, so the fallback recovers targets that flocf_{\mathrm{loc}} misses there. A prior that localizes the target too rarely loses most of its benefit: SAT-Nano places the initial view center inside the target about as often as the ROI search of DeepSeek-V4.1-Flash, so with either MLLM, the performance with SAT-Nano stays much closer to that without a prior than to that with flocf_{\mathrm{loc}}. TriSegAgent therefore gains directly from a more accurate localization model.

Generalization to unseen datasets. With every MLLM, TriSegAgent outperforms flocf_{\mathrm{loc}} and floc→fsegf_{\mathrm{loc}}\rightarrow f_{\mathrm{seg}} on the unseen datasets of flocf_{\mathrm{loc}}, on the datasets unseen by both flocf_{\mathrm{loc}} and fsegf_{\mathrm{seg}} (C4), and on the datasets never used while developing TriSegAgent (Table S10). This result extends Figure 6 from two MLLMs to all eight, and with frontier MLLMs, TriSegAgent also outperforms flocf_{\mathrm{loc}} over all ROIs. Since fsegf_{\mathrm{seg}} raises the Dice of flocf_{\mathrm{loc}} only slightly on these datasets, the gain comes from the agent, which checks the initial prediction in tri-planes and corrects it through clicks. The lead is largest on the datasets never used in development, so it does not stem from tuning the agent to its development data.

Targets with several lesions. On the five datasets whose targets have several separate lesions, TriSegAgent reaches a higher mean Dice with every MLLM than nnInteractive Agent with any MLLM (Table S11). This lead holds although TriSegAgent grows its initial prediction from the main component of the localization prior (Sec. D.1).

DatasetROIsLesionsTriSegAgent: GPT-5.6-SolTriSegAgent: Claude-Sonnet-5.5TriSegAgent: GPT-6.1-SolTriSegAgent: Gemini-3.8-FlashTriSegAgent: GPT-6-AstrannInteractive Agent: GPT-5.6-SolnnInteractive Agent: Claude-Sonnet-5.5nnInteractive Agent: GPT-6.1-Sol
WMH326 [14, 29]58.756.761.634.161.154.855.751.9
COVID-19412.5 [1, 34]42.640.041.845.542.632.731.949.7
autoPET321 [3, 76]35.933.134.736.036.04.426.14.4
LNQ 2023152 [1, 5]47.948.451.648.150.917.824.036.3
CRLM152 [1, 8]55.834.651.738.055.938.134.050.3
All five402 [1, 76]50.241.850.142.151.628.731.141.7

Table S11. Performance on the five datasets whose targets have several separate lesions (40 ROIs). Lesions: median number of separate lesions in a ground-truth mask, with the range in brackets. COVID-19 combines COVID-19-20 and COVID-19-CT-Seg. The first three MLLMs of TriSegAgent are those that nnInteractive Agent also runs, and the best result in the All five row is bolded.

Input Layout

With both MLLMs, tri-planes are the most context-efficient input layout without loss in performance (Table S12). With Gemini-3.8-Flash, a slice stack uses more input tokens per ROI as the number of slices grows, whereas its performance stays below that of tri-planes at every number of slices. A stack of 16 slices uses 4.1× as many input tokens per ROI as tri-planes with DeepSeek-V4.1-Flash and 12× as many with Gemini-3.8-Flash. It also uses nearly twice as many reasoning tokens with both MLLMs. Placing three panels side by side in one image is an implementation choice that tri-planes share with the “3 in one image” stack (§ 4.1). With the same placement and the same number of panels, tri-planes need fewer input and reasoning tokens than three parallel axial slices with both MLLMs. With Gemini-3.8-Flash, they also need fewer calls and perform better, since they show the view along three axes rather than one.

MLLMLayoutSlices / viewCalls / ROI↓Tokens / ROI Input↓Tokens / ROI Reasoning↓Dice MeanDice Median
DeepSeek-V4.1-FlashSlice stack16–49.4k61.0k63.575.9
3 in one image–13.5k43.2k64.077.0
Tri-planes312.1k32.8k63.879.1
Gemini-3.8-FlashSlice stack1614.4337.1k28.4k63.078.3
913.6191.7k25.1k63.978.4
514.2119.1k24.1k63.378.8
313.975.0k21.2k62.577.9
3 in one image13.032.9k18.9k63.979.0
Tri-planes311.728.1k15.5k65.879.3

Table S12. Ablation on the input layout with DeepSeek-V4.1-Flash and Gemini-3.8-Flash. Slice stack: parallel axial slices around the view center, one image per slice except for “3 in one image”; Tokens / ROI: total over all MLLM calls.

Harness Design Ablation

Harness designs with DeepSeek-V4.1-Flash. Each design of the harness helps DeepSeek-V4.1-Flash as it helps Gemini-3.8-Flash in Table 3 (Table S13). Removing the prior mask lowers the performance the most, since fsegf_{\mathrm{seg}} then starts from a single click instead of the prior. Multi-view verification lowers the false accepts while keeping the performance. Click selection improves the performance of both MLLMs on the smallest ROIs, below 1.5 cm (Table S9), where a click that the MLLM places itself can fall outside the target when it is a few pixels off.

MLLMClick selection<1.5 (28)1.5–3 (41)3–6 (60)≥6 (61)All (190)
DeepSeek-V4.1-Flash×25.253.364.083.862.3
DeepSeek-V4.1-Flash✓31.750.764.586.763.8
Gemini-3.8-Flash×33.452.258.983.061.4
Gemini-3.8-Flash✓36.757.966.084.465.8

Table S9. Ablation of click selection by ROI size. × marks the removed design, and the shaded row of each MLLM is the full TriSegAgent. The number of ROIs is below each size.

MLLMPrior maskClick selectionMulti-view verificationDice MeanDice MedianDice SmallDice LargeFA↓
DeepSeek-V4.1-Flash×✓✓52.662.633.963.230
✓×✓62.376.641.974.023
✓✓×63.779.042.675.728
✓✓✓63.879.143.075.723
Gemini-3.8-Flash×✓✓53.063.837.162.125
✓×✓61.477.944.671.015
✓✓×65.179.148.574.616
✓✓✓65.879.349.375.312

Table S13. Ablation of the harness with DeepSeek-V4.1-Flash and Gemini-3.8-Flash. Marks and columns as in Table 3.

Multi-view verification by ROI shape. With both MLLMs, multi-view verification lowers the number of accepted ROIs with a Dice below 50% on both complex and compact ROIs (Table S14), so it catches wrong predictions on targets of either shape. We group ROIs by their sphericity ψ\psi as in Sec. F. Complex ROIs (ψ<0.386\psi< 0.386) are mostly tubular, ring-shaped, or branching structures, such as the aorta, myocardium, and airway, whereas compact ROIs are rounder structures, such as the liver, spleen, and lymph nodes.

MLLMMulti-view verificationAccepted with Dice <50%↓ ComplexAccepted with Dice <50%↓ CompactMean Dice ComplexMean Dice Compact
DeepSeek-V4.1-Flash×172960.165.3
✓122360.665.2
Gemini-3.8-Flash×122259.667.5
✓101859.868.5

Table S14. Ablation of multi-view verification by ROI shape. Complex: ROIs with ψ<0.386\psi< 0.386 (58); Compact: the others (132). × marks the removed design, and the shaded row of each MLLM is the full TriSegAgent.

Coverage of the verification views. The first verification view of each round already shows at least one remaining error region in the large majority of rounds, and most of the error regions on its own (Table S15). We measure this coverage on the runs of Gemini-3.8-Flash and DeepSeek-V4.1-Flash on the 190-ROI subset. From their logged views, predictions, and ground truth, we compute whether a view shows an error region (Sec. E.1) without new MLLM calls. We count views with the same center and side length as one view, since they show the same images. We leave out a band of τ=2\tau= 2 mm along the boundary of M∗M^*, so that thin boundary disagreements do not count. We report three fractions γ\gamma; an error region that covers 10% of the target lowers Dice by about five points on its own. For the first view of each round, this measurement gives pcovp_{\mathrm{cov}} in Proposition S4.

γ\gammaPer roundPer error region
Gemini-3.8-FlashDeepSeek-V4.1-FlashGemini-3.8-FlashDeepSeek-V4.1-Flash
5%95.5 [90.5, 99.2] (111)95.8 [91.9, 99.1] (120)85.8 [78.8, 92.0] (169)82.2 [75.3, 88.7] (197)
10%95.6 [89.9, 100.0] (90)93.8 [87.7, 98.9] (96)89.8 [83.2, 95.9] (108)83.7 [77.4, 89.9] (129)
25%94.8 [87.9, 100.0] (58)92.5 [85.7, 98.4] (67)90.6 [83.3, 97.1] (64)85.7 [78.2, 93.0] (77)

Table S15. Coverage of the verification views. The shares are measured on the first view of each round, with τ=2\tau= 2 mm. Per round: among the rounds whose prediction has an error region, the share in which the view shows at least one. Per error region: share of the error regions in these rounds shown by the view. Brackets: 95% bootstrap intervals over ROIs; parentheses: number of rounds or error regions.

Model Choices and Hyperparameters

Reasoning effort. TriSegAgent keeps its performance at other reasoning efforts with either MLLM (Table S16). With Gemini-3.8-Flash, high effort produces far more reasoning tokens per reply but does not improve the performance. With DeepSeek-V4.1-Flash, low effort uses fewer reasoning tokens per reply and keeps the performance.

MLLMEffortReas.MeanMedianSmallLarge
DeepSeek-V4.1-FlashLow248964.277.541.377.2
Medium275163.879.143.075.7
Gemini-3.8-FlashHigh457765.679.048.575.3
Medium103065.879.349.375.3

Table S16. Ablation on the reasoning effort. Reas.: median number of reasoning tokens per model reply.

Interactive segmentation model. The harness exchanges only clicks and 3D predictions with fsegf_{\mathrm{seg}}, so it works with other interactive segmentation models. MedSAM2 [75] segments a 3D volume by propagating 2D predictions across slices. With MedSAM2 in place of nnInteractive, TriSegAgent performs similarly without any change to the harness (Table S17).

Hyperparameters. The performance of TriSegAgent changes little around the default call budget (Figure S2) and the default prior fill (Figure S2). Since most ROIs finish within about ten calls, the curve levels off after about 14 calls, well below the default limit of 26. A rerun with a budget of 40 calls performs similarly, so the default does not limit TriSegAgent. Because F0F_0 takes one of three preset sizes, a different prior fill changes the initial view of about one in seven ROIs. At the other two fill values, the performance stays close to its value at the default fill, and the confidence interval of each change covers zero. The findings of the main paper therefore do not depend on finely tuned hyperparameters.

Statistical Analysis

This section gives the uncertainty of the results in Table 1. We resample the 690 ROIs with replacement 4,000 times to obtain 95% bootstrap intervals. ROIs from the same scan share an image, and ROIs from the same dataset share an annotation protocol and similar difficulty. We therefore also resample whole datasets 4,000 times, which gives wider and more conservative intervals. A paired difference between two systems uses the same resamples for both. We test each pair of systems with the Wilcoxon signed-rank test and correct the pp-values over all pairs with Holm’s method.

All leads of TriSegAgent over nnInteractive Agent with GPT-6.1-Sol and over VoxTell are significant, and leaving out any single dataset does not reverse any of them (Table S18).

MLLMΔ\DeltaCI (ROI)CI (dataset)ppΔ\DeltaCI (ROI)CI (dataset)pp
GPT-6.1-Sol+9.1[+6.8, +11.6][+3.6, +14.5]1.5×10−191.5 \times10^{-19}+10.4[+7.9, +12.9][+4.3, +18.7]2.1×10−132.1 \times10^{-13}
Claude-Opus-5.5+9.5[+7.1, +11.9][+2.4, +15.4]3.6×10−233.6 \times10^{-23}+10.7[+8.3, +13.2][+4.4, +18.9]1.4×10−231.4 \times10^{-23}
GPT-6-Astra+10.3[+8.2, +12.5][+4.8, +15.5]3.9×10−253.9 \times10^{-25}+11.6[+9.4, +13.9][+5.4, +20.1]3.5×10−173.5 \times10^{-17}

Table S18. Lead of TriSegAgent over the two strongest baselines in Table 1 (690 ROIs). Δ\Delta: difference in mean Dice (points) with 95% bootstrap intervals over ROIs and over whole datasets; pp: Wilcoxon signed-rank test, Holm-corrected over all pairs of systems. Leaving out any single dataset does not reverse any of these differences.

A repeated run of TriSegAgent gives nearly the same performance. We ran TriSegAgent with Gemini-3.8-Flash a second time on all 690 ROIs through another API endpoint. Its mean Dice changes by 0.3 points (95% interval [−0.8, +1.5]), and 81% of the ROIs change by less than one point. The standard error that model randomness adds to the mean (0.42 points) is well below the standard error from sampling ROIs (1.16 points).

Qualitative Results

Figure S3 compares the 3D predictions of TriSegAgent with those of the baselines across ROI types and modalities, and Figure S4 shows how one click refines a 3D prediction on four more ROIs.

Comparison of 3D segmentation across ROI types and modalities

Figure S3. Comparison of 3D segmentation across ROI types and modalities. Gray is the ground truth and orange the 3D prediction; a panel without orange has no prediction in view. nnI-Agent: nnInteractive Agent [48] with GPT-6.1-Sol [85]; TriSegAgent runs with Gemini-3.8-Flash [38].

Figure S4. One click of TriSegAgent on four ROIs. Each row shows the same view before and after the click, with the candidate clicks in between and a blue circle on the one that the MLLM picks. The left column names the part that the MLLM confirms as missing, and the corner of each view gives the Dice of the 3D prediction.

MLLM Prompts

Every MLLM call in TriSegAgent sends one decision prompt as the system message and the labeled images as the user message (“Image 1”, or “stack 1, slice 3/16” in a search stack). Each call thus asks for exactly one visual judgment. Table S19 maps each prompt to the step of the loop at which the harness calls it. The boxes below give the text of each prompt in the default configuration. All prompts stay the same for every MLLM and every benchmark dataset. Text in angle brackets, such as ⟨target⟩, is a slot that the harness fills at run time. The lower part of each box lists the values of these slots. Most prompts share two passages: one describes the layout of the tri-planar panels, and the other gives the annotation standard for the ROI type. We give their full text once in P0, and the other prompts show only the corresponding slots, ⟨tri-planar panel layout⟩ and ⟨ROI standard⟩.

PromptStep of the loopDescribed inImagesAnswers
P1Choosing the initial predictionSec. Dtwo sets of tri-planes, one per proposalmask start, point start, neither, unsure
P2Retry after the proposal from P0P_0 failsSec. Done set of tri-planes with numbered ringsone ring, none, unsure
P3Verification view§ 3.3one set of tri-planesaccept, error with box, wrong structure, unsure
P4Confirming an error (step ①)Sec. Done set of tri-planes centered on the boxconfirm, withdraw
P5Click selection (step ③)§ 3.3one set of tri-planes with numbered ringsone ring, none, unsure
P6, P7Committing a proposal (step ④)Sec. Done set of tri-planes of the proposalon target, wrong structure, unsure
P8Committing a large correctionSec. Dtwo or four sets of tri-planes, before and afterimproved, not improved, unsure
P9ROI searchSec. D16 axial slices, one image eachone point, unsure
P10First click after the ROI searchSec. Done set of tri-planesone point, unsure

Table S19. MLLM prompts of TriSegAgent. Each prompt is listed with the step of the loop at which the harness calls it.

P0 Shared blocks. Inserted where a prompt shows the slot tri-planar panel layout or ROI standard. The ROI standard is fixed text selected by the ROI type (organ, bone, vessel, tumor, muscle, node, or a generic text for an unknown type); three of the seven are shown.

⟨tri-planar panel layout⟩

Image 1 is a tri-view: three panels side by side, AX (axial), SAG (sagittal) and COR (coronal). Each panel is one 2D slice of the scan, and the three slices cross at the panel centres. Letters at the panel edges mark the patient’s right, left, front, back, head and foot (R, L, A, P, S, I), so you can tell left from right. Panels without letters have unknown orientation: judge structures by anatomy, not by side.

⟨ROI standard⟩ (organ)

The mask should cover the whole organ seen here, including the vessels and hilum inside its outline. It must not include neighbouring organs, the fat between them, or vessels outside the organ. An error is a missing pole, lobe or segment, or red crossing the fat plane into a neighbour.

⟨ROI standard⟩ (vessel)

The mask should follow the lumen of the named vessel along its course here. It must not follow a parallel vessel or the organ it enters. Thin side branches do not count. An error is a gap longer than the vessel is wide, or red following a different vessel.

⟨ROI standard⟩ (tumor)

Every lesion seen here is target tissue, as the name defines it (whole tumour, enhancing part, …). The mask must not include normal tissue around a lesion. Its edge is often blurred: a few millimetres either way is fine. An error is a lesion with no red, or red reaching well beyond a lesion into normal tissue.

P1 Choosing the initial prediction. Called three times with sampled answers, which decide by majority. Images: the proposal from P0P_0 (Image 1) and the point-based proposal (Image 2), each drawn on the tri-planes of the initial view.

You are a skilled annotator choosing how a 3D segmentation should start.

⟨tri-planar panel layout⟩ (with “Image 1” replaced by “Each image is”)

Red is a candidate first mask, shown where it crosses each slice. Both images are centred where a separate localizer placed the target; the localizer can be wrong.

Image 1: the mask the segmentation tool made from the localizer’s own segmentation of the target (⟨voxels 1⟩ voxels).

Image 2: the mask the tool grew from one point placed inside the localizer’s segmentation (⟨voxels 2⟩ voxels).

The target is: ⟨target⟩. Each panel is ⟨F⟩ mm wide.

⟨ROI standard⟩

Choose the better start: the mask that lies on the target’s tissue and covers more of it. It does not have to be complete or tidy: missing parts, a rough outline and small overspill are fixed later. Image 1 keeps the localizer’s outline, so it is often irregular or has extensions along the target; those are usually target tissue, and a smoother outline in Image 2 is not by itself a reason to prefer Image 2. Prefer Image 2 when Image 1 clearly crosses into a neighbouring structure or covers only a small part of the target.

Answer no_valid_candidate only when the red in both images sits on a different structure than the target: a rough mask that lies on the target is a valid start.

Answer with one JSON object:

{"decision":"use_localizer_mask"} start from Image 1
{"decision":"select_seed_candidate","candidate_id":"⟨point label⟩"} start from Image 2
{"decision":"no_valid_candidate"} both masks sit on a different structure than the target
{"decision":"uncertain"} the images do not show enough to decide

⟨target⟩ The text goal qq, e.g., “left kidney in abdomen CT”.

⟨F⟩ Side length of the view in mm.

⟨voxels 1⟩, ⟨voxels 2⟩ Voxel counts of the two proposals.

P2 Choosing a point after the proposal from P0P_0 fails

Called three times with sampled answers, which decide by majority, once the proposal from P0P_0 has been rejected (Sec. D). Image: the tri-planes of the initial view, showing up to five numbered rings, plus a magnified crop when the rings lie close together.

You are a skilled annotator choosing where a 3D segmentation should start.

⟨tri-planar panel layout⟩

In one panel, yellow rings labelled ⟨labels⟩ mark candidate points; each point is the centre of its ring.⟨crop⟩

The target is: ⟨target⟩. Each panel is ⟨F⟩ mm wide. The segmentation tool will grow a 3D mask outward from the one point you choose, so the point must lie on the target’s tissue. Choose the ring whose centre is on the target. If several are, prefer one away from the target’s edge and away from neighbouring organs and vessels.

Answer with one JSON object:

{"decision":"select_seed_candidate","candidate_id":"⟨first label⟩"} the label you chose
{"decision":"no_valid_candidate"} no ring centre is on the target
{"decision":"uncertain"} the image is too unclear to decide

⟨labels⟩ Labels of the rings, one per candidate point.

⟨crop⟩ Empty, or, when the rings lie close together: “The rings are close together, so Image 2 is a magnified crop of that part of Image 1, showing the same rings with the same labels.”

P3 Judging a verification view

Called once per verification view in V(Mt)\mathcal{V}(M_t), and at most twice more while the answer stays unsure. Image: the tri-planes of that view with MtM_t as a red overlay; on the view of the uncovered prior, the uncovered part of P0P_0 is outlined in blue.

You are a skilled annotator checking a segmentation.

⟨tri-planar panel layout⟩

The red overlay is the current 3D mask of the target, shown where it crosses each slice. This view is centred ⟨placement⟩. Several such views are checked in turn, and the mask is accepted only when all of them pass.

The target is: ⟨target⟩. Each panel is ⟨F⟩ mm wide.⟨last change⟩

The target may consist of several pieces (tumours, nodes, a row of vertebrae): every piece in the view is target tissue. A target that names a side or a level (the left kidney, L3) is one piece: its counterpart and the levels above and below are not the target.

What counts as an error here:

  • fn: tissue that is certainly part of the target, with no red on it.

  • fp: red on tissue that is certainly not the target (another organ, bone, vessel, fat, air), or red crossing the border into a neighbour. Not an error: a boundary off by a voxel or two; a slice near the edge of the structure that shows only a thin sliver or a small patch of red, which is how a 3D mask looks there; tissue you cannot confidently assign to the target.

⟨ROI standard⟩ If you see a clear error, mark it with a coarse rectangle in the panel where it is clearest; the exact point is chosen from candidates inside the rectangle in the next step, and the claim is checked on a view centred there before anything changes. Judge only what these slices show. When in doubt, accept: a missed sliver costs less than a wrong correction.

Answer with one JSON object:

{"decision":"accept_local","confidence":"medium|high"} no clear error here
{"decision":"localize_error","error_type":"fn|fp","panel":"axial|sagittal|coronal",
  "region":{"x0":0,"y0":0,"x1":1000,"y1":1000}}
{"decision":"wrong_structure"} the red as a whole follows another structure that you can name, and the target has no red
{"decision":"uncertain"} these slices do not show enough to decide

⟨placement⟩ By verification view: “at the centre of the first view” (initial view); “at the centre of the mask” (centroid); “where the last change to the mask was made”, or “where the last correction added tissue” / “removed tissue” / “changed the mask” (last change); “on the surface of the mask”; “on a separate piece of the mask”; “on the mask, one zoom level out, to judge the structure as a whole” (overview). On the view of the uncovered prior: “on the largest region that a separate localizer assigned to the target but the red mask does not cover, outlined in blue. Decide whether the blue region is target tissue the mask misses (then mark it as fn there) or another structure (then accept)”.

⟨last change⟩ Empty, or one sentence on the last change: “The mask was just created from a separate localizer’s segmentation (⟨n⟩ voxels).”; “The mask was just created from the point you chose (⟨n⟩ voxels).”; “The last correction added a positive (negative) point; the mask gained ⟨a⟩ voxels and lost ⟨b⟩, to ⟨n⟩ voxels.”

Confirming an error

Called for each box that the overlay does not contradict (Sec. D). Image: the tri-planes of a view centered on the box, with a crosshair at its center.

You are checking a claim about a segmentation.

⟨tri-planar panel layout⟩

The red overlay is the current 3D mask of the target, shown where it crosses each slice. The three slices meet at the crosshair, which sits on tissue that an earlier check marked as ⟨claim⟩.

The target is: ⟨target⟩. Each panel is ⟨F⟩ mm wide.

⟨ROI standard⟩

Measured on the marked slice: ⟨measurements⟩

First name the tissue at the crosshair, then decide:

  • confirm: the claim is right. ⟨confirm rule⟩

  • withdraw: the claim is wrong, or these slices do not let you tell. A wrong correction costs more than a missed sliver, so withdraw when in doubt.

Answer with one JSON object:

{"decision":"confirm","tissue":"<the tissue at the crosshair>"}
{"decision":"withdraw","tissue":"<the tissue at the crosshair>"}

⟨claim⟩ fn: “target tissue that the mask missed”; fp: “red lying on tissue that is not the target”.

⟨confirm rule⟩ fn: “The tissue at the crosshair is certainly part of the target and has no red.”; fp: “The red at the crosshair certainly lies on something other than the target.”

⟨measurements⟩ Up to six sentences computed in code: “The box is ⟨w⟩ × ⟨h⟩ mm and ⟨p⟩ of it is red.”; fn only: “Its nearest red voxel is ⟨d⟩ mm away.”; “The tissue in the box outside the red (fp: The red in the box) is ⟨z⟩ standard deviations brighter (darker) than the mask’s own tissue; ⟨p⟩ of it falls within the mask’s usual intensity range.”; fp only: “The red in the box belongs to a piece holding ⟨p⟩ of the mask.”; “On this slice the mask’s cross-section is ⟨p⟩ of its largest cross-section.”; fn only, for organs, muscles and vessels: “A separate localizer’s own mask of the target has ⟨p⟩ of its voxels outside the red mask; the marked region lies in (does not lie in) that uncovered part.”

P5 Selecting a click

Called after an error is confirmed. Image: the tri-planes, showing up to five numbered rings inside the box, yellow for a missing part and cyan for an extra part, plus a magnified crop when the rings lie close together.

You are a skilled annotator choosing a correction point.

⟨tri-planar panel layout⟩

Red is the current mask.

In one panel, ⟨colour⟩ rings labelled ⟨labels⟩ mark candidate points inside the rectangle you drew; each point is the centre of its ring. ⟨crop⟩

The target is: ⟨target⟩. Each panel is ⟨F⟩ mm wide. You marked ⟨marked⟩ there.

⟨rule⟩

Answer with one JSON object:

{"decision":"select_candidate","candidate_id":"⟨first label⟩"} the label you chose

{"decision":"no_valid_candidate"} no ring centre fits

{"decision":"uncertain"} the image is too unclear to decide

⟨colour⟩, ⟨marked⟩ fn: “yellow”, “missed target tissue (fn)”; fp: “cyan”, “red on non-target tissue (fp)”.

⟨rule⟩ fn: “The chosen point will be a positive click: the segmentation tool grows the mask to include the tissue around it. Choose a ring whose centre is on target tissue that is not red. If several are, prefer one well inside the missed region.”

fp: “The chosen point will be a negative click: the segmentation tool removes the red around it. Choose a ring whose centre is on red that covers non-target tissue. If several are, prefer one well inside the wrong red, away from the target.”

⟨crop⟩ As in P2.

P6 Confirming the initial prediction

Called on the chosen proposal after the basic checks pass. Image: the tri-planes of the initial view with the proposal as a red overlay.

You are a skilled annotator checking a first segmentation attempt.

⟨tri-planar panel layout⟩

⟨source⟩

The target is: ⟨target⟩. Each panel is ⟨F⟩ mm wide.

⟨ROI standard⟩

Decide whether this mask is a usable start. It does not have to be complete: missing parts and small overspill are fixed later.

  • accept_trial: the red lies on the target’s tissue and covers a solid part of it.

  • wrong_structure: the red as a whole follows another structure that you can name (a neighbouring organ, a vessel, the counterpart), and the target itself has no red.

  • uncertain: you cannot tell, or the red is only a tiny speck of the target.

Answer with one JSON object:

{"decision":"accept_trial","confidence":"medium|high"}

{"decision":"wrong_structure"}

{"decision":"uncertain"}

⟨source⟩ Proposal from P0P_0: “The red overlay is a 3D mask that the segmentation tool made from a separate localizer’s segmentation of the target, shown where it crosses each slice. The panels are centred where the localizer placed the target; the localizer can be wrong.” Point-based proposal: “The red overlay is a 3D mask that the segmentation tool grew from the point you chose, shown where it crosses each slice. The panels are centred where they were before: your point lies on the slice of the panel its ring was shown in, and the other two slices may cut the mask off-centre or miss it.”

P7 Confirming a prediction after a click

Called on every proposal from a click after the basic checks pass. Image: the tri-planes of the proposal as a red overlay.

You are a skilled annotator checking a correction to a segmentation.

⟨tri-planar panel layout⟩

The red overlay is the 3D mask after your correction point was added as a ⟨purpose⟩, shown where it crosses each slice. The mask changed from ⟨n before⟩ to ⟨n after⟩ voxels.

The target is: ⟨target⟩. Each panel is ⟨F⟩ mm wide.

⟨ROI standard⟩

Decide only whether the mask still follows the target. It may still be incomplete or spill a little; that is checked separately.

  • accept_trial: the red still lies on the target’s tissue.

  • wrong_structure: the red as a whole now follows another structure that you can name, and the target itself has no red.

  • uncertain: you cannot tell.

Answer with one JSON object:

{"decision":"accept_trial","confidence":"medium|high"}

{"decision":"wrong_structure"}

{"decision":"uncertain"}

⟨purpose⟩ Positive click: “positive point to fill a missed region”; negative click: “negative point to remove overspill”.

P8 Comparing a prediction before and after a click

Called after P7 accepts a proposal from a click that changes the prediction strongly, e.g., by adding a distant component. Images: the tri-planes of the same view before and after the click (Images 1 and 2) and, when available, a second before/after pair centered where the prediction changed most (Images 3 and 4).

You are a skilled annotator judging whether a correction improved a segmentation.

⟨tri-planar panel layout⟩ (with “Image 1 is” replaced by “Each image is”)

Red is the mask.

Image 1 and Image 2 show the same view before and after the correction: same centre, same slices, same field of view.⟨second pair⟩

The target is: ⟨target⟩. Each panel is ⟨F⟩ mm wide. You added a ⟨point⟩.

The mask gained ⟨a⟩ voxels and lost ⟨b⟩, from ⟨n before⟩ to ⟨n after⟩ voxels; ⟨p⟩ of it changed, across ⟨s⟩ mm.⟨retained⟩ The change is checked before it is kept.

⟨ROI standard⟩

  • accept_repair: the error you marked is fixed, and the change stays on the target: added red is target tissue, removed red was not.

  • reject_repair: the error is not fixed, or the change spills onto other tissue or removes target tissue.

  • uncertain: the images do not show enough to decide.

Answer with one JSON object:

{"decision":"accept_repair","confidence":"medium|high"}

{"decision":"reject_repair"}

{"decision":"uncertain"}

⟨second pair⟩ Empty, or “ Image 3 and Image 4 are a second before/after pair, centred where the correction changed the mask most.”

⟨point⟩ Positive click: “positive point to fill missed target tissue”; negative click: “negative point to remove red on non-target tissue”.

⟨retained⟩ Empty, or “⟨p⟩ of the previous mask is retained.”

⟨s⟩ Largest extent of the changed region along the three axes.

P9 Searching for the target without a localization prior

Called when flocf_{\mathrm{loc}} finds nothing, or when no initial prediction is committed from its prior. Round 1 shows 16 axial slices through the whole scan; round 2 shows 16 axial slices through a 96 mm window around the round-1 point. Each image is preceded by its label, e.g., “stack 1, slice 3/16”.

You are a skilled annotator finding where a target lies in a 3D scan.

A view is a stack of 16 axial slices, one image per slice. The text before each image names its stack and slice (“stack 1, slice 3/16”) and each panel’s corner reads AX k/16. The slices are in order from the foot end to the head end when the scan’s orientation is known (else in slice order). Letters at the panel edges mark the patient’s right, left, front and back (R, L, A, P), so you can tell left from right. Panels without letters have unknown orientation: judge structures by anatomy, not by side. There is no sagittal or coronal panel: name a panel by its slice, “ax<k>” (slice 3 is “ax3”).

<round>

The target is: <target>. An automatic localizer could not find it, so find it from the anatomy. The segmentation tool will grow a 3D mask outward from the point you give, so the point must lie on the target’s tissue, well inside it, in the slice where it is clearest. Each slice is <F> mm wide.

<earlier attempts>

Answer with one JSON object:

{"decision":"place_point","panel":"ax<k>","x":500,"y":500} the panel and the point’s position in it: x 0..1000 from left to right, y 0..1000 from top to bottom

{"decision":"uncertain"} the target is not visible in any slice

<round>

Round 1: “The 16 slices are spaced evenly through the whole scan, from one end to the other, so the target may lie between two of them: pick the slice where it is clearest, or the slice nearest to it.” Round 2: “The 16 slices cover a 96 mm window around the point you chose on the whole scan, at finer spacing, so you can place the point precisely.”

<F>

Round 1: the width of the scan; round 2: 96.

<earlier attempts>

Empty, or, when a point fell outside the scan and is asked again: “Earlier attempts on this image, which you must not repeat:” followed by one line per attempt, “- the point at x <x>, y <y> in the <panel> panel lies outside the scan”.

Called on a 128 mm view centered at the point found by P9. The MLLM places the point itself, since no localization prior is left to sample candidate points from; the resulting prediction is then confirmed with P6.

You are a skilled annotator choosing where a 3D segmentation should start.

<tri-planar panel layout>

The panels are centred where your search through the whole scan placed the target. It can be wrong, so find the target from the anatomy.

The target is: <target>. Each panel is <F> mm wide. The segmentation tool will grow a 3D mask outward from the one point you give, so the point must lie on the target’s tissue. Prefer a point well inside the target, away from its edge and away from neighbouring organs and vessels. Place it in the panel where the target is clearest.

<earlier attempts>

Answer with one JSON object:

{"decision":"place_point","panel":"axial|sagittal|coronal","x":500,"y":500} the panel and the point’s position in it: x 0..1000 from left to right, y 0..1000 from top to bottom

{"decision":"uncertain"} the target is not in the image or it is too unclear to decide

<earlier attempts>

Empty, or “Earlier attempts on this image, which you must not repeat:” followed by one line per earlier point, “- the point at x <x>, y <y> in the <panel> panel <result>”, where <result> is one of “grew a mask on a different structure than the target”, “grew a mask that could not be confirmed as the target”, “produced no mask”, “grew a mask over far more than the target”, “lies outside the scan”, “lies within 5 mm of a point that grew a different structure”, or “was already tried”.

References

  1. [1]Marah Abdin, Jyoti Aneja, Hany Awadalla, Ahmed Awadallah, Ammar Ahmad Awan, Nguyen Bach, Amit Bahree, Arash Bakhtiari, Jianmin Bao, Harkirat Behl, et al. Phi-3 technical report: A highly capable language model locally on your phone. arXiv preprint arXiv:2404.14219, 2024. 7arxiv.org/abs/2404.14219
  2. [2]Hugo J W L Aerts, Emmanuel Rios Velazquez, Ralph T H Leijenaar, Chintan Parmar, Patrick Grossmann, Sara Carvalho, Johan Bussink, René Monshouwer, Benjamin Haibe-Kains, Derek Rietveld, et al. Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach. Nature Communications, 5:4006, 2014. 28DOI
  3. [3]Ayahallah A Ahmed, Mohab M Elmohr, David Fuentes, Mouhammed A Habra, Sarah B Fisher, Nancy D Perrier, Miao Zhang, and Khaled M Elsayes. Radiomic mapping model for prediction of Ki-67 expression in adrenocortical carcinoma. Clinical Radiology, 75(6):479.e17–479.e22, 2020. 28DOI
  4. [4]Tugba Akinci D’Antoni, Lucas K Berger, Ashraya K Indrakanti, Nathan Vishwanathan, Jakob Weiss, Matthias Jung, Zeynep Berkarda, Alexander Rau, Marco Reisert, Thomas Küstner, et al. TotalSegmentator MRI: Robust sequence-independent segmentation of multiple anatomic structures in MRI. Radiology, 314(2):e241613, 2025. 28DOI
  5. [5]Anthropic. Claude Code. Software, 2025. 6, 29
  6. [6]Anthropic. System card: Claude Opus 5.5, 2026. 3, 7
  7. [7]Anthropic. System card: Claude Sonnet 5.5, 2026. 7
  8. [8]Michela Antonelli, Annika Reinke, Spyridon Bakas, Keyvan Farahani, Annette Kopp-Schneider, Bennett A Landman, Geert Litjens, Bjoern Menze, Olaf Ronneberger, Ronald M Summers, et al. The medical segmentation decathlon. Nature Communications, 13:4128, 2022. 28
  9. [9]Anwai Archit, Luca Freckmann, Sushmita Nair, Nabeel Khalid, Paul Hilt, Vikas Rajasekhar, Marei Freitag, Carolin Teuber, Melanie Spitzner, Constanza Tapia Contreras, et al. Segment anything for microscopy. Nature Methods, 22(3):579–591, 2025. 2
  10. [10]Samuel G Armato, Henkjan Huisman, Karen Drukker, Lubomir Hadjiski, Justin S Kirby, Nicholas Petrick, George Redmond, Maryellen L Giger, Kenny Cha, Artem Mamonov, et al. PROSTATEx challenges for computerized classification of prostate lesions from multiparametric magnetic resonance images. Journal of Medical Imaging, 5(4):044501, 2018. 28DOI
  11. [11]Fan Bai, Yuxin Du, Tiejun Huang, Max Q-H Meng, and Bo Zhao. M3D: Advancing 3D medical image analysis with multi-modal large language models. arXiv preprint arXiv:2404.00578, 2024. 2, 4, 6, 7arxiv.org/abs/2404.00578
  12. [12]Shuai Bai, Yuxuan Cai, Ruizhe Chen, Keqin Chen, Xionghui Chen, Zesen Cheng, Lianghao Deng, Wei Ding, Chang Gao, Chunjiang Ge, et al. Qwen3-VL technical report. arXiv preprint arXiv:2511.21631, 2025. 7arxiv.org/abs/2511.21631
  13. [13]Shuai Bai, Keqin Chen, Xuejing Cui, Jialin Wang, Wenbin Ge, Sibo Song, Kai Dang, Peng Wang, Shijie Wang, Jun Tang, et al. Qwen2.5-VL technical report. arXiv preprint arXiv:2502.13923, 2025. 2, 4arxiv.org/abs/2502.13923
  14. [14]Ujjwal Baid, Satyam Ghodasara, Suyash Mohan, Michel Bilello, Evan Calabrese, Errol Colak, Keyvan Farahani, Jayashree Kalpathy-Cramer, Felipe C Kitamura, Sarthak Pati, et al. The RSNA-ASNR-MICCAI BraTS 2021 benchmark on brain tumor segmentation and radiogenomic classification. arXiv preprint arXiv:2107.02314, 2021. 28
  15. [15]Spyridon Bakas, Hamed Akbari, Aristotelis Sotiras, Michel Bilello, Martin Rozycki, Justin S Kirby, John B Freymann, Keyvan Farahani, and Christos Davatzikos. Advancing The Cancer Genome Atlas glioma MRI collections with expert segmentation labels and radiomic features. Scientific Data, 4:170117, 2017. 28DOI
  16. [16]Olivier Bernard, Alain Lalande, Clement Zotti, Frederick Cervenansky, Xin Yang, Pheng-Ann Heng, Irem Cetin, Karim Lekadir, Oscar Camara, Miguel Angel Gonza-lez Ballester, et al. Deep learning techniques for automatic MRI cardiac multi-structures segmentation and diagnosis: Is the problem solved? IEEE Transactions on Medical Imaging, 37(11):2514–2525, 2018. 28
  17. [17]B Nicholas Bloch, Anant Madabhushi, Henkjan Huisman, John Freymann, Justin Kirby, Michael Grauer, Andinet Enquobahrie, Carl Jaffe, Larry Clarke, and Keyvan Farahani. NCI-ISBI 2013 challenge: Automated segmentation of prostate structures. The Cancer Imaging Archive, 2015. 28DOI
  18. [18]Kevin M Boergens, Manuel Berning, Tom Bocklisch, Dominic Bräunlein, Florian Drawitsch, Johannes Frohnhofen, Tom Herold, Philipp Otto, Norman Rzepka, Thomas Werkmeister, et al. webKnossos: efficient online 3D data annotation for connectomics. Nature Methods, 14(7):691–694, 2017. 2DOI
  19. [19]Ross Callaghan, Niannu Gao, Hojjat Azadbakht, and Hui Zhang. Medical image alignment assessment as a test of generalist visual reasoning in frontier multimodal models. arXiv preprint arXiv:2610.06896, 2026. 2, 4arxiv.org/abs/2610.06896
  20. [20]Nicolas Carion, Laura Gustafson, Yuan-Ting Hu, Shoubhik Debnath, Ronghang Hu, Didadac Suris, Chaitanya R Vali, Kalyan Vasudev Alwala, Haitham Khedr, Andrew Huang, et al. SAM 3: Segment anything with concepts. In ICLR, 2026. 4
  21. [21]Santiago Cepeda, Sergio García-García, Ignacio Arrese, Francisco Herrero, Trinidad Escudero, Tomás Zamora, and Rosario Sarabia. The Río Hortega university hospital glioblastoma dataset: A comprehensive collection of pre-operative, early postoperative and recurrence MRI scans (RHUH-GBM). Data in Brief, 50:109617, 2023. 28
  22. [22]Kenneth Clark, Bruce Vendt, Kirk Smith, John Freymann, Justin Kirby, Paul Koppel, Stephen Moore, Stanley Phillips, David Maffitt, Michael Pringle, et al. The cancer imaging archive (TCIA): Maintaining and operating a public information repository. Journal of Digital Imaging, 26(6):1045–1057, 2013. 27DOI
  23. [23]Gheorghe Comanici, Eric Bieber, Mike Schaekermann, Ice Pasupat, Noveen Sachdeva, Inderjit Dhillon, Marcel Blistein, Ori Ram, Dan Zhang, Evan Rosen, et al. Gemini 2.5: Pushing the frontier with advanced reasoning, multimodality, long context, and next generation agentic capabilities. arXiv preprint arXiv:2507.06261, 2025. 2, 4arxiv.org/abs/2507.06261
  24. [24]Coen de Vente, Kiran Vaidhya Venkadesh, Andras Lasso, Bram van Ginneken, and Clara I Sánchez. SlicerNNInteractive: A 3D Slicer extension for nnInteractive.arxiv.org/abs/2504.07991
  25. [25]DeepSeek-AI. DeepSeek-V4-1-Flash: Pushing the limits of KV cache compression. arXiv preprint arXiv:2609.19969, 2026. 3, 7
  26. [26]Reuben Dorent, Aaron Kujawa, Marina Ivory, Spyridon Bakas, Nicola Rieke, Samuel Joutard, Ben Glocker, Jorge Cardoso, Marc Modat, Kayhan Batmanghelich, et al. CrossMoDA 2021 challenge: Benchmark of cross-modality domain adaptation techniques for vestibular schwannoma and cochlea segmentation. Medical Image Analysis, 83:102628, 2023. 28
  27. [27]Reuben Dorent, Roya Khajavi, Tagwa Idris, Erik Ziegler, Bhanuspriya Somarouthu, Heather Jacene, Ann LaCasce, Jonathan Deissler, Jan Ehrhardt, Sofija Engelson, et al. LNQ 2023 challenge: Benchmark of weakly-supervised techniques for mediastinal lymph node quantification. Machine Learning for Biomedical Imaging, 2025(MICCAI 2023 LNQ challenge special issue):1–15, 2025. 28DOI
  28. [28]Yuxin Du, Fan Bai, Tiejun Huang, and Bo Zhao. SegVol: Universal and interactive volumetric medical image segmentation. In NeurIPS, 2024. 4, 6, 7, 16
  29. [29]Adibvafa Fallahpour, Jun Ma, Alif Munim, Hongwei Lyu, and Bo Wang. MedRAX: Medical reasoning agent for chest X-ray. In ICML, 2025. 4arxiv.org/abs/2502.02673
  30. [30]Chengyu Feng, Heng Guo, Zheng Jiang, Chunming He, Xiu Li, and Minfeng Xu. Photon: Speedup volume understanding with efficient multimodal large language models. In ICLR, 2026. 4arxiv.org/abs/2603.25155
  31. [31]Andriy Fedorov, Reinhard Beichel, Jayashree Kalpathy-Cramer, Julien Finet, Jean-Christophe Fillion-Robin, Sonia Pujol, Christian Bauer, Dominique Jennings, Fiona Fennessy, Milan Sonka, et al. 3D Slicer as an image computing platform for the quantitative imaging network. Magnetic Resonance Imaging, 30(9):1323–1341, 2012. 2, 4DOI
  32. [32]Andriy Fedorov, Michael Schwier, David Clunie, Christian Herz, Steve Pieper, Ron Kikinis, Clare Tempany, and Fiona Fennessy. An annotated test-retest collection of prostate multiparametric MRI. Scientific Data, 5:180281, 2018. 28DOI
  33. [33]Chaoyou Fu, Yuhan Dai, Yongdong Luo, Lei Li, Shuhuai Ren, Renrui Zhang, Zihan Wang, Chenyu Zhou, Yunhang Shen, Mengdan Zhang, et al. Video-MME: The first-ever comprehensive evaluation benchmark of multi-modal LLMs in video analysis. In CVPR, 2025. 4
  34. [34]Shangqi Gao, Hangqi Zhou, YiBo Gao, Xia Hai Zhuang. BayesSeg: Bayesian modeling for medical image segmentation with interpretable generalizability. Medical Image Analysis, 89:102889, 2023. 28
  35. [35]Sergios Gatidis, Tobias Hepp, Marcel Früh, Christian La Fougère, Konstantin Nikolaou, Christina Pfannenberg, Bernhard Schölkopf, Thomas Küstner, Clemens Cyran, and Daniel Rubin. A whole-body FDG-PET/CT dataset with manually annotated tumor lesions. Scientific Data, 9:601, 2022. 28DOI
  36. [36]Petko Georgiev, Ying Ian Lei, Ryan Burnell, Libin Bai, Anmol Gulati, Garrett Tanzer, Damien Vincent, Zhufeng Pan, Shibo Wang, Soroosh Marioryad, et al. Gemini 1.5: Unlocking multimodal understanding across millions of tokens of context. arXiv preprint arXiv:2403.05530, 2024. 3, 4arxiv.org/abs/2403.05530
  37. [37]Daniel Golden and Fereshteh Mahvar. Next generation medical image interpretation with MedGemma 1.5 and medical speech to text with MedASR. Google Research Blog, 2026. 2, 4
  38. [38]Google DeepMind. Gemini 3.8 Flash model card, 2026. 3, 7, 35
  39. [39]Ibrahim Ethem Hamamci, Sezgin Er, Chenyu Wang, Furkan Almas, Ayse Gulnihan Simsek, Sevval Nil Esirgun, Irem Dogan, Omer Faruk Durugol, Benjamin Hou, Suprosanna Shit, et al. Generalist foundation models from a multimodal dataset for 3D computed tomography. Nature Biomedical Engineering, 10(8):1610–1628, 2026. 4DOI
  40. [40]Moritz R Hernandez Petzsche, Ezequiel de la Rosa, Uta Hanning, Roland Wiest, Waldo Valenzuela, Mauricio Reyes, Maria Meyer, Sook-Lei Liew, Florian Kofler, Ivan Ezhov, et al. ISLES 2022: A multi-center magnetic resonance imaging stroke lesion segmentation dataset. Scientific Data, 9:762, 2022. 28DOI
  41. [41]Andrew Hoopes, Neel Dey, Victor Ion Butoi, John V Guttag, and Adrian V Dalca. VoxelPrompt: A vision agent for end-to-end medical image analysis. arXiv preprint arXiv:2410.08397, 2024. 4arxiv.org/abs/2410.08397
  42. [42]Cheng-Ping Hsieh, Simeng Sun, Samuel Kriman, Shantanu Acharya, Dima Rekesh, Fei Jia, Yang Zhang, and Boris Ginsburg. RULER: What’s the real context size of your long-context language models? In COLM, 2024. 2arxiv.org/abs/2404.06654
  43. [43]Yushi Hu, Weijia Shi, Xingyu Fu, Dan Roth, Mari Osten-dorf, Luke Zettlemoyer, Noah A Smith, and Ranjay Krishna. Visual Sketchpad: Sketching as a visual chain of thought for multimodal language models. In NeurIPS, 2024. 2arxiv.org/abs/2406.09403
  44. [44]Zimo Huang, Tian Xia, Tianfu Wu, Bing Liu, Shengfu Huang, Lei Bi, and Jinman Kim. Dental odontogenic lesion CBCT and histopathology integrated dataset for benchmarking deep learning algorithms. Scientific Data, 13:758, 2026. 6, 27, 28DOI
  45. [45]Tagwa Idris, Supriya Somarouthu, Heather Jacene, Ann La-Casce, Erik Ziegler, Steve Pieper, Roya Khajavi, Reuben Dorent, Sonia Pujol, Ron Kikinis, et al. Mediastinal lymph node quantification (LNQ): Segmentation of heterogeneous CT data (version 1). The Cancer Imaging Archive, 2024. 28
  46. [46]International Organization for Standardization. ISO 5456-2:1996, technical drawings – projection methods – part 2: Orthographic representations, 1996. 2
  47. [47]Fabian Isensee, Maximilian Rokuss, Lars Krämer, Stefan Dinkelacker, Ashis Ravindran, Florian Stritzke, Benjamin Hamm, Tassilo Wald, Moritz Langenberg, Constantin Ul-rich, et al. nnInteractive: Redefining 3D promptable segmentation. arXiv preprint arXiv:2503.08373, 2025. 2, 4, 6, 8, 16, 17, 26, 29, 33arxiv.org/abs/2503.08373
  48. [48]Fabian Isensee, Constantin Ulrich Harsy, Maximilian Rokuss, Benjamin Hamm, Philipp Vollmuth, and Klaus H Maier-Hein. nnInteractive Agent: General-purpose AI agents as 3D image annotators. arXiv preprint arXiv:2610.31080, 2026. 3, 4, 6, 7, 8, 29, 35arxiv.org/abs/2610.31080
  49. [49]Yuanfeng Ji, Haotian Bai, Chongjian Ge, Jie Yang, Ye Zhu, Ruimao Zhang, Zhen Li, Lingyan Zhang, Wanling Ma, Xi-ang Wan, et al. AMOS: A large-scale abdominal multi-organ benchmark for versatile medical image segmentation. In NeurIPS, pages 36722–36732, 2022. 28arxiv.org/abs/2206.08023
  50. [50]Chongcong Jiang, Tianxinjian Ding, Chuhan Song, Ji-achen Tu, Yizhang Yan, Yihua Shao, Zhenyi Wang, Yuzhang Shang, Tianyu Han, and Yu Tian. Medical SAM3: A foundation model for universal prompt-driven medical image segmentation. arXiv preprint arXiv:2601.10880, 2026. 4arxiv.org/abs/2601.10880
  51. [51]Yankai Jiang, Qiaoru Li, Binlu Xu, Haoran Sun, Chao Ding, Junting Dong, Yuxiang Cai, Xuhong Zhang, and Jian-wei Yim. IBISAgent: Reinforcing pixel-level visual reasoning in MLLMs for universal biomedical object referring and segmentation. arXiv preprint arXiv:2601.03054, 2026. 4, 17arxiv.org/abs/2601.03054
  52. [52]Alexandros Karargyris, Renato Umeton, Micah J Sheller, Alejandro Aristizabal, Johnu George, Anna Wuest, Sarthak Pati, Hasan Kassem, Maximilian Zenk, Ujjwal Baid, et al. Federated benchmarking of medical artificial intelligence with MedPerf. Nature Machine Intelligence, 5(7):799–810, 2023. 28DOI
  53. [53]A Emre Kavur, N Sinem Gezer, Mustafa Barış, Sinem Aslan, Pierre-Henri Conze, Vladimir Groza, Duc Duy Pham, Soumick Chatterjee, Philipp Ernst, Savaş Özkan, et al. CHAOS challenge—combined (CT-MR) healthy abdominal organ segmentation. Medical Image Analysis, 69:101950, 2021. 28DOI
  54. [54]Alexander Kirillov, Eric Mintun, Nikhila Ravi, Hanzi Mao, Chloe Rolland, Laura Gustafson, Tete Xiao, Spencer Whitehead, Alexander C Berg, Wan-Yen Lo, et al. Segment anything. In ICCV, 2023. 2, 4, 16, 17arxiv.org/abs/2304.02643
  55. [55]Hugo J Kuijf, J Matthijs Biesbroek, Jeroen De Bresser, Rutger Heinen, Simon Andermatt, Mariana Bento, Matt Berseth, Mikhail Belyaev, M Jorge Cardoso, Adrià Casamitjana, et al. Standardized assessment of automatic segmentation of white matter hyperintensities and results of the WMH segmentation challenge. IEEE Transactions on Medical Imaging, 38(11):2556–2568, 2019. 28DOI
  56. [56]LangChain. LangGraph. Software, 2024. 6
  57. [57]Mosh Levy, Alon Jacoby, and Yoav Goldberg. Same task, more tokens: the impact of input length on the reasoning performance of large language models. In ACL, 2024. 2arxiv.org/abs/2402.14848
  58. [58]Binxu Li, Tiankai Yan, Yuanting Pan, Jie Luo, Ruiyang Ji, Jiyuan Ding, Zhe Xu, Shiling Liu, Haoyu Dong, Zihao Lin, et al. MMedAgent: Learning to use medical tools with multi-modal agent. In Findings of EMNLP, 2024. 4arxiv.org/abs/2407.02483
  59. [59]Bo Li, Yuanhan Zhang, Dong Guo, Renrui Zhang, Feng Li, Hao Zhang, Kaichen Zhang, Peiyuan Zhang, Yanwei Li, Zi-wei Liu, and Chunyan Li. LLaVA-OneVision: Easy visual task transfer. Transactions on Machine Learning Research, 2025. 3, 4arxiv.org/abs/2408.03326
  60. [60]Kaixin Li, Ziyang Meng, Hongzhan Lin, Ziyang Luo, Yuchen Tian, Jing Ma, Zhiyong Huang, and Tat-Seng Chua. ScreenSpot-Pro: GUI grounding for professional high-resolution computer use. In ACM MM, pages 8778–8786, 2025. 2arxiv.org/abs/2504.07981
  61. [61]Wenxuan Li, Chongyu Qu, Xiaoxi Chen, Pedro R A S Bassi, Yijia Shi, Yuxiang Lai, Qian Yu, Huimin Xue, Yixing Chen, Xiaorui Lin, et al. AbdomenAtlas: A large-scale, detailed-annotated, & multi-center dataset for efficient transfer learning and open algorithmic benchmarking. Medical Image Analysis, 97:103285, 2024. 28
  62. [62]Yanwei Li, Chengyao Wang, and Jiaya Jia. LLaMA-VID: An image is worth 2 tokens in large language models. In ECCV, 2024. 4
  63. [63]Xiaomin Liang, Linda A Alpuing Radilla, Kamand Khalaj, Haaniya Dawoodally, Chinmay Mokashi, Xiaoming Guan, Kirk E Roberts, Sunil A Sheth, Varaha S Tammisetti, and Luca Giancardo. A multi-modal pelvic MRI dataset for deep learning-based pelvic organ segmentation in endometriosis. Scientific Data, 12:1292, 2025. 6, 28DOI
  64. [64]Bin Lin, Yang Ye, Bin Zhu, Jiaxi Cui, Munan Ning, Peng Jin, and Li Yuan. Video-LLaVA: Learning united visual representation by alignment before projection. In EMNLP, 2024. 3
  65. [65]Zheng Lin, Zhao Zhang, Lin-Zhuo Chen, Ming-Ming Cheng, and Shao-Ping Lu. Interactive image segmentation with first click attention. In CVPR, pages 13339–13348, 2020. 8
  66. [66]Anglin Liu, Xu R Cao, Yifan Shen, Yi Lu, Xiang Li, Qianqian Chen, and Jintai Chen. MedSAM3: Delving into segment anything with medical concepts. arXiv preprint arXiv:2511.19046, 2025. 4
  67. [67]Jie Liu, Yixiao Zhang, Jie-Neng Chen, Junfei Xiao, Yongyi Lu, Bennett A Landman, Yixuan Yuan, Alan Yuille, Yucheng Tang, and Zongwei Zhou. CLIP-driven universal model for organ segmentation and tumor detection. In ICCV, 2023. 4DOI
  68. [68]Shengyuan Liu, Liuxin Bao, Qi Yang, Wanting Geng, Boyun Zheng, Chenxin Li, Wenting Chen, Houwen Peng, and Yixuan Yuan. MedSAM-Agent: Empowering interactive medical image segmentation with multi-turn agentic reinforcement learning. arXiv preprint arXiv:2602.03320, 2026. 2, 4, 6, 7, 17, 29arxiv.org/abs/2602.03320
  69. [69]Shengyuan Liu, Zun Tangting Ye, Yunrui Lin, Chen Hu, Wanting Geng, Xu Han, Bulat Ibragimov, Yefeng Zheng, and Yixuan Yuan. MedPruner: Training-free hierarchical token pruning for efficient 3D medical image understanding in vision-language models. arXiv preprint arXiv:2603.11625, 2026. 4arxiv.org/abs/2603.11625
  70. [70]Xiangde Luo, Wenjun Liao, Jianghong Xiao, Jieneng Chen, Tao Song, Xiaofan Zhang, Kang Li, Dimitris N Metaxas, Guotai Wang, and Shaoting Zhang. WORD: A large scale dataset, benchmark and clinical applicable study for abdominal organ segmentation from CT image. Medical Image Analysis, 82:102642, 2022. 28DOI
  71. [71]Xiangde Luo, Jia Fu, Yunxin Zhong, Shuolin Liu, Bing Han, Mehdi Astaraki, Simone Bendazzoli, Iuliana Toma-Dasu, Yiwen Ye, Ziyang Chen, et al. SegRap2023: A benchmark of organs-at-risk and gross tumor volume segmentation for radiotherapy planning of nasopharyngeal carcinoma. Medical Image Analysis, 101:103447, 2025. 28
  72. [72]Jun Ma, Yixin Wang, Xingle An, Cheng Ge, Ziqi Yu, Jianan Chen, Qiong jie Zhu, Guoqiang Dong, Jian He, Zhiqiang He, et al. Toward data-efficient learning: A benchmark for COVID-19 CT lung and infection segmentation. Medical Physics, 48(3):1197–1210, 2021. 28DOI
  73. [73]Jun Ma, Yuting He, Feifei Li, Lin Han, Chenyu You, and Bo Wang. Segment anything in medical images. Nature Communications, 15(1):654, 2024. 4
  74. [74]Jun Ma, Yao Zhang, Song Gu, Cheng Ge, Shihao Mae, Adamo Young, Cheng Zhu, Xin Yang, Kangkang Meng, Ziyan Huang, et al. Unleashing the strengths of unlabelled data in deep learning-assisted pan-cancer abdominal organ quantification: the FLARE22 challenge. The Lancet Digital Health, 6(11):e815–e826, 2024. 27DOI
  75. [75]Jun Ma, Zongxin Yang, Sumin Kim, Bihui Chen, Mohammed Baharoon, Adibvafa Fallahpour, Reza Asakereh, Hongwei Lyu, and Bo Wang. MedSAM2: Segment anything in 3D medical images and videos. arXiv preprint arXiv:2504.03600, 2025. 2, 4, 16, 29, 33
  76. [76]Jun Ma, Sumin Kim, Yuyin Zhou, and Bo Wang, editors. Foundation Models for 3D Biomedical Image Segmentation: CVPR 2025 Challenge, MedSegFM 2025. Springer, 2026. 26, 28
  77. [77]Zdravko Marinov, Paul F Jäger, Jan Egger, Jens Kleesiek, and Rainer Stiefelhagen. Deep interactive segmentation of medical images: A systematic review and taxonomy. IEEE Transactions on Pattern Analysis and Machine Intelligence, 46(12):10998–11018, 2024. 2, 16
  78. [78]Zdravko Marinov, Moon Kim, Jens Kleesiek, and Rainer Stiefelhagen. Rethinking annotator simulation: Realistic evaluation of whole-body PET lesion interactive segmentation methods. arXiv preprint arXiv:2404.0816, 2024. 17arxiv.org/abs/2404.01816
  79. [79]Bjoern H Menze, Andras Jakab, Stefan Bauer, Jayashree Kalpathy-Cramer, Keyvan Farahani, Justin Kirby, Yuliya Burren, Nicole Porz, Johannes Slotboom, Roland Wiest, et al. The multimodal brain tumor image segmentation benchmark (BRATS). IEEE Transactions on Medical Imaging, 34(10):1993–2024, 2015. 28DOI
  80. [80]Ahmed W Moawad, Ayahallah A Ahmed, Mohab M ElMohr, Mohamed Eltaher, Mouhammed Amir Habra, Sarah B Fisher, Nancy D Perrier, Miao Zhang, David Fuentes, and Khaled M Elsayes. Voxel-level segmentation of pathologically-proven adrenocortical carcinoma with Ki-67 expression (Adrenal-ACC-Ki67-Seg). The Cancer Imaging Archive, 2023. 28DOI
  81. [81]Vishwesh Nath, Wenqi Li, Dong Yang, Andriy Myronenko, Mingxin Zheng, Yao Lu, Zhijian Liu, Hongxu Yin, Yucheng Tang, Pengfei Guo, et al. VILA-M3: Enhancing vision-language models with medical expert knowledge. In CVPR, 2025. 4
  82. [82]S. D. Olabarriaga and A. W. M. Smeulders. Interaction in the segmentation of medical images: A survey. Medical Image Analysis, 5(2):127–142, 2001. 2, 16
  83. [83]OpenAI. Codex CLI. Software, 2025. 6, 8, 29
  84. [84]OpenAI. GPT-5.6 system card, 2026. 7
  85. [85]OpenAI. Addendum to GPT-6 Astra system card: GPT-6.1 Sol, 2026. 3, 6, 7, 29, 35
  86. [86]OpenAI. GPT-6 Astra system card, 2026. 3, 7
  87. [87]Andan S Pandit, Andrew Keenlyside, Danyal Z Khan, Gerda Reischer, Muhammad A Kamal, Nina Yoh, Zane Jaumunktane, Anouk Borg, Neil L Dorward, Stefanie E Baldeweg, et al. Mapping pituitary neuroendocrine tumors: An annotated MRI dataset profiling tumor and carotid characteristics. Scientific Data, 12:80, 2025. 6, 28DOI
  88. [88]Gašper Podobnik, Primož Strojan, Primož Peterlin, Bulat Ibragimov, and Tomaž Vrtovec. HaN-Seg: The head and neck organ-at-risk CT and MR segmentation dataset. Medical Physics, 50(3):1917–1927, 2023. 28DOI
  89. [89]Zihan Qiu, Zekun Wang, Xiao Li, Yanpeng Li, Yang Xu, Yixuan Wang, Huaqing Zhang, Rui Men, Bochao Mao, Chengruidong Zhang, et al. On the design of Qwen3.8-Next architecture: Evaluation, efficiency, and training stability. arXiv preprint arXiv:2608.30320, 2026. 3, 30arxiv.org/abs/2608.30320
  90. [90]Lukas Radl, Yuan Jin, Antonio Pepe, Jianning Li, Christina Gsaxner, Fen-hua Zhao, and Jan Egger. AVT: Multicenter aortic vessel tree CTA dataset collection with ground truth segmentation masks. Data in Brief, 40:107801, 2022. 28DOI
  91. [91]Pooyan Rahmanzadehgeravi, Logan Bolton, Mohammad Reza Taesiri, and Anh Totti Nguyen. Vision language models are blind. In ACCV, 2024. 2, 5
  92. [92]Maximilian Rokuss, Moritz Langenberg, Yannick Kirchhoff, Fabian Isensee, Benjamin Hamm, Constantin Ulrich, Sebastian Regnery, Lukas Bauer, Ephraim Katsiampoploulos, Tobias Norajitra, et al. VoxTell: Free-text promptable universal 3D medical image segmentation. In CVPR, 2026. 4, 6, 7
  93. [93]Mélanie Roschewitz, Kenneth Styppa, Yitian Tao, Jiwoong Sohn, Jean-Benoit Delbrouck, Benjamin Gundersen, Nicolas Deperrois, Christian Bluethgen, Julia E. Vogt, Bjoern Menze, et al. RadAgent: A tool-using AI agent for step-wise interpretation of chest computed tomography. arXiv preprint arXiv:2604.15231, 2026. 4arxiv.org/abs/2604.15231
  94. [94]Holger R Roth, Ziyue Xu, Carlos Tor-Díez, Ramon Sanchez Jacob, Jonathan Zember, Jose Molto, Wenqi Li, Sheng Xu, Baris Turkbey, Evrim Turkmen, et al. Rapid artificial intelligence solutions in a pandemic—the COVID-19-20 lung CT lesion segmentation challenge. Medical Image Analysis, 82:102605, 2022. 28
  95. [95]Weixiang Shang, Chengzhi Shen, Che Liu, Junde Wu, Jiayuan Zhu, Xiao Han, Zongyue Li, Jingpei Wu, Min Xu, Daguang Xu, et al. MedFlowBench: Auditing medical agents in full-study workflows. In NeurIPS, 2026. 4arxiv.org/abs/2603.24649
  96. [96]Xiaoqian Shen, Yunyang Xiong, Changsheng Zhao, Lemeng Wu, Jun Chen, Chenchen Zhu, Zechun Liu, Fanyi Xiao, Balakrishnan Varadarajan, Florian Bordes, et al. LongVU: Spatiotemporal adaptive compression for long video-language understanding. In ICML, 2025. 4
  97. [97]Yan Shu, Zheng Liu, Peitian Zhang, Minghao Qin, Junjie Zhou, Zhengyang Liang, Tiejun Huang, and Bo Zhao. Video-XL: Extra-long vision language model for hour-scale video understanding. In CVPR, 2025. 4
  98. [98]Amber L Simpson, Jacob Peoples, John M Creasy, Gabor Fichtinger, Natalie Gangai, Krishna N Keshavamurthy, Andreas Lasso, Jinru Shia, Michael I D’Angelica, and Richard K G Do. Preoperative CT and survival data for patients undergoing resection of colorectal liver metastases. Scientific Data, 11:172, 2024. 28
  99. [99]Konstantin Sofiiuk, Ilia A Petrov, and Anton Konushin. Reviving iterative training with mask guidance for interactive segmentation. In ICIP, 2022. 2, 16, 17
  100. [100]Enxin Song, Wenhao Chai, Guanhong Wang, Yucheng Zhang, Haoyang Zhou, Feiyang Wu, Haozhe Chi, Xun Guo, Tian Ye, Yanting Zhang, et al. MovieChat: From dense token to sparse memory for long video understanding. In CVPR, 2024. 4
  101. [101]Quoc-Huy Trinh, Xi Ding, Yang Liu, Zhenyue Qin, Xingjian Li, Gorkem Durak, Halil Ertugrul Aktas, Andrea M Bejar, Ulas Bagci, and Min Xu. Beyond medical diagnostics: How medical multimodal large language models think in space. arXiv preprint arXiv:2603.13800, 2026. 4arxiv.org/abs/2603.13800
  102. [102]Kareem A Wahid, Cem Dede, Dina M El-Habashy, Serageldin Kamel, Michael K Rooney, Yomna Khamis, Moamen R A Abdelaal, Sara Ahmed, Kelsey L Corrigan, et al. Overview of the head and neck tumor segmentation for magnetic resonance guided applications (HNTS-MRG) 2024 challenge. In MICCAI HNTS-MRG Challenge, pages 1–35, 2025. 28
  103. [103]Haoyu Wang, Sizheng Guo, Jin Ye, Zhongying Deng, Junlong Cheng, Tianbin Li, Jianpin Chen, Yanzhou Su, Ziyan Huang, Yiqing Shen, et al. SAM-Med3D: Towards general-purpose segmentation models for volumetric medical images. In ECCV Workshops, 2024. 4, 16
  104. [104]Hengyi Wang, Haizhou Shi, Shiwei Tan, Weiyi Qin, Wenyuan Wang, Tunyu Zhang, Akshay Nambi, Tanuja Ganu, and Hao Wang. Multimodal needle in a haystack: Benchmarking long-context capability of multimodal large language models. In NAACL, 2025. 2
  105. [105]Peng Wang, Shuai Bai, Sinan Tan, Shijie Wang, Zhihao Fan, Jinze Bai, Keqin Chen, Xuejing Liu, Jialin Wang, Wenbin Ge, et al. Qwen2-VL: Enhancing vision-language model’s perception of the world at any resolution. arXiv preprint arXiv:2409.12191, 2024. 3arxiv.org/abs/2409.12191
  106. [106]Yuli Wang, Peng Jian, Yuwei Dai, Craig Jones, Haris Sair, Jinglai Shen, Nicolas Loizou, Jing Wu, Wen-Chi Hsu, Maliha Imami, et al. Eta: Enhancing vision-language models for medical imaging: bridging the 3D gap with innovative slice selection. In NeurIPS Datasets and Benchmarks Track, 2024. 2, 4
  107. [107]Ziyue Wang, Linghan Cai, Chang Han Low, Haofeng Liu, Junde Wu, Jingyu Wang, Rui Wang, Lei Song, Jiang Bian, Jingjing Fu, et al. 3DMedAgent: Unified perception-to-understanding for 3D medical analysis. arXiv preprint arXiv:2602.18064, 2026. 4arxiv.org/abs/2602.18064
  108. [108]Jakob Wasserthal, Hanns-Christian Breit, Manfred T Meyer, Maurice Pradella, Daniel Hinck, Alexander W Sauter, Tobias Heye, Daniel T Boll, Joshy Cyriac, Shan Yang, et al. TotalSegmentator: robust segmentation of 104 anatomic structures in CT images. Radiology: Artificial Intelligence, 5(5):e230024, 2023. 28DOI
  109. [109]Leonard Wee, Hugo J W L Aerts, Petros Kalandralis, and Andre Dekker. RIDER lung CT segmentation labels from: Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach. The Cancer Imaging Archive, 2020. 28
  110. [110]Ivo Wolf, Marcus Vetter, Ingmar Wegner, Thomas Böttger, Marco Nolden, Max Schöbinger, Mark Hastenteufel, Tobias Künert, and Hans-Peter Meinzer. The medical imaging interaction toolkit. Medical Image Analysis, 9(6):594–604, 2005. 4
  111. [111]Chaoyi Wu, Xiaomian Zhang, Ya Zhang, Hui Hui, Yanfeng Wang, and Weidi Xie. Towards generalist foundation model for radiology by leveraging web-scale 2D&3D medical data. Nature Communications, 16(1):7866, 2025. 2, 4
  112. [112]Fuping Wu and Xiahai Zhuang. Minimizing estimated risks on unlabeled data: A new formulation for semi-supervised medical image segmentation. IEEE Transactions on Pattern Analysis and Machine Intelligence, 45(5):6021–6036, 2023. 28DOI
  113. [113]Zhaodong Wu, Qiaochu Zhao, Ming Hu, Yulong Li, Haochen Xue, Zhengyong Jiang, Angelos Stefanidis, Qiufeng Wang, Imran Razzak, Zongyuan Ge, et al. MSWAL: 3D multi-class segmentation of whole abdominal lesions dataset. In MICCAI, pages 378–388, 2025. 6, 28arxiv.org/abs/2503.13560
  114. [114]Yu Xin, Gorkem Can Ates, and Wei Shao. Text3DSAM: Text-guided 3D medical image segmentation using SAM-inspired architecture. In Foundation Models for 3D Biomedical Image Segmentation: CVPR 2025 Challenge, 2026. 4, 6, 7DOI
  115. [115]Jinzhong Yang, Harini Veeraraghavan, Samuel G Armato, Keyvan Farahani, Justin S Kirby, Jayashree Kalpathy-Kramer, Wouter van Elmp, Andre Dekker, Xiao Han, Xue Feng, et al. Autosegmentation for thoracic radiation treatment planning: A grand challenge at AAPM 2017. Medical Physics, 45(10):4568–4581, 2018. 28DOI
  116. [116]Jianwei Yang, Hao Zhang, Feng Li, Xueyuan Zou, Chunyuan Li, and Jianfeng Gao. Set-of-mark prompting unleashes extraordinary visual grounding in GPT-4V. arXiv preprint arXiv:2310.11441, 2023. 2, 5arxiv.org/abs/2310.11441
  117. [117]Lin Yang, Shawn Xu, Andrew Sellergren, Timo Kohlberger, Yuchen Zhou, Ira Ktena, Atilla Kiraly, Faruk Ahmed, Farhad Hormozdiari, Tiam Jaroensri, et al. Advancing multimodal medical capabilities of Gemini. arXiv preprint arXiv:2405.03162, 2024. 4arxiv.org/abs/2405.03162
  118. [118]Shunyu Yao, Jeffrey Zhao, Dian Yu, Nan Du, Izhak Shafran, Karthik Narasimhan, and Yuan Cao. ReAct: Synergizing reasoning and acting in language models. In ICLR, 2023. 2arxiv.org/abs/2210.03629
  119. [119]Dingqiang Ye, Dongdi Zhao, Kaishen Wang, Qingqiao Hu, Jingchen Sun, Yijun Liang, Yuqi Jia, Yiqiao Huang, Yunjie Tian, Jiaxing Zhang, Chuanyang Jin, Ke Zhang, Vishal M. Patel, and Di Fu. VideoResearcher: Self-improving tool design for long-video understanding. arXiv preprint arXiv:2609.19664, 2026. 4arxiv.org/abs/2609.19664
  120. [120]Paul A Yushkevich, Joseph Piven, Heather Cody Hazlett, Rachel Gimpel Smith, Sean Ho, James C Gee, and Guido Gerig. User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. NeuroImage, 31(3):1116–1128, 2006. 2, 4
  121. [121]Minghui Zhang, Yangqian Wu, Hanxiao Zhang, Yulei Qin, Hao Zheng, Wen Tang, Corey Arnold, Chenhao Pei, Pengxin Yu, Yang Nan, et al. Multi-site, multi-domain airway tree modeling. Medical Image Analysis, 90:102957, 2023. 28DOI
  122. [122]Binsheng Zhao, Leonard P James, Chaya S Moskowitz, Pingzhen Guo, Michelle S Ginsberg, Robert A Lefkowitz, Yilin Qin, Gregory J Riely, Mark G Kris, and Lawrence H Schwartz. Evaluating variability in tumor measurements from same-day repeat CT scans of patients with non-small cell lung cancer. Radiology, 252(1):263–272, 2009. 28
  123. [123]Theodore Zhao, Yu Gu, Jianwei Yang, Naoto Usuyama, Ho Hin Lee, Sid Kiblawi, Tristan Naumann, Jianfeng Gao, Angela Crabtree, Jacob Abel, et al. A foundation model for joint segmentation, detection and recognition of biomedical objects across nine modalities. Nature Methods, 22(1):166–176, 2025. 6, 29, 31DOI
  124. [124]Theodore Zhao, Sid Kiblawi, Naoto Usuyama, Ho Hin Lee, Sam Preston, Hoifung Poon, and Mu Wei. Boltzmann attention sampling for image analysis with small objects. In CVPR, 2025. 6, 29arxiv.org/abs/2503.02841
  125. [125]Ziheng Zhao, Yao Zhang, Chaoyi Wu, Xiaomian Zhang, Xiao Zhou, Ya Zhang, Yanfeng Wang, and Weidi Xie. Large-vocabulary segmentation for medical images with text prompts. npj Digital Medicine, 8(1):566, 2025. 4, 6, 7, 29
  126. [126]Junjie Zhou, Yan Shu, Bo Zhao, Boya Wu, Zhengyang Liang, Shitao Xiao, Minghao Qin, Xi Yang, Yongping Xiong, Bo Zhang, et al. MLVU: Benchmarking multi-task long video understanding. In CVPR, 2025. 4
  127. [127]Mizhu Zhu, Yuzhuo Tian, Hao Chen, Chunluan Zhou, Qingpei Guo, Yang Liu, Ming Yang, and Chunhua Shen. SegAgent: Exploring pixel understanding capabilities in MLLMs by imitating human annotator trajectories. In CVPR, 2025. 2, 4, 17arxiv.org/abs/2503.08625
  128. [128]Xiahai Zhuang. Multivariate mixture model for myocardial segmentation combining multi-source images. IEEE Transactions on Pattern Analysis and Machine Intelligence, 41(12):2933–2946, 2019. 28DOI

Paper details

vlnc:W_c9xqp5uj
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 2

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Computer Science

Claude Code, Codex

View statement
Looking for related papers…
Contents