WorksPhysics and Astronomy
Quantifying the importance of equation of state and transport property compatibility in supercritical fluids
Abstract
High-fidelity simulation of supercritical flows requires accurate values of thermodynamic properties including the density (rho), specific heat cp, enthalpy h, and entropy s as well as transport properties such as the viscosity (eta) and thermal conductivity (lambda) as functions of the temperature T and pressure P. In simulations of mixtures, such as supercritical carbon dioxide (sCO2) with contaminants, a generalized equation of state (EoS) is often used, leading to errors in rho(T,P) when compared to results from correlations developed specifically for individual species. Similarly, generalized correlations for eta and lambda are often used, with a corresponding decrease in accuracy. However, a second source of error is introduced in calculations of transport properties. These correlations are created and computed as functions of T and rho instead of as functions of T and P. Because of this, when eta(T,rho )and lambda(T,rho) are calculated, errors in rho(T,P) propagate through the calculation. This work creates a procedure for tracking both errors caused by using a generalized correlation for eta(T,rho) and lambda(T,rho), and for tracking the errors caused by using a generalized correlation for rho(T,P) in these calculations. The viscosity and thermal conductivity of supercritical CO2, N2, andCH4 are used as examples to demonstrate how to separate the errors due to the generalized property correlations and the errors due to the generalized EoS. Both sources of error are largest near the critical temperature Tc. These errors are large enough to impact both the numeric stability and the accuracy of simulations.
Introduction
Accurate computation of properties for supercritical fluids often requires complex equations of state, or EoSs, to accurately compute thermodynamic properties such as the density , specific heat , enthalpy , and entropy as functions of the temperature and pressure . These are complemented by correlations to calculate transport properties such as viscosity and thermal conductivity . A major challenge for both EoSs and transport properties correlations is balancing computational cost, accuracy, and generalizability. For example, for supercritical carbon dioxide, or sCO, the Span–Wagner EoS [1] or related correlations [2] will provide the most accurate values of , , and . The complexity of these correlations is large enough that machine-learning models have been proposed to accelerate computation of these properties [3]. However, when substantial contaminants appear, such as in Venus’s atmosphere [4], oxycombustion in sCO ambient systems [5, 6, 7], hydrogen hydrothermal combustion [8] or green chemistry processes [9, 10, 11], it is necessary to use a generalized EoS, such as the Soave–Redlich–Kwong (SRK) [12] or Peng–Robinson [13] EoS. For a given mixture, these EoSs allow calculation of , , and .
A similar set of challenges exists for calculation of transport properties such as viscosity and thermal conductivity . The same distinction exists: high-fidelity correlations are available for pure species. For example, for sCO the Laesecke–Muzny and Huber correlations for and are available [14, 15]. However, once other species are present, generalized models such as the Chung correlation for and become necessary [16].
A major concern when using these correlations in engineering calculations, including computational fluid dynamics, is how errors in the values in both thermodynamics variables such as , , and , and transport properties such as and impact results. Because the variation in properties makes even conduction a highly non-linear process near the critical point [17], small errors in can lead to large differences in predicted behavior. Similarly, even when the transport properties are calculated accurately, differences between different equations of state can lead to large differences in flow structure and heat transfer for engineering systems [18]. Variations in thermodynamic properties will also impact reacting flow calculations, leading to differences in observed peak temperatures and pollutant formation [5].
An additional potential source of error for calculation of transport properties for supercritical fluids is that they are not derived or calculated as functions of and , i.e. and . Instead they are written as functions of temperature and density: and . This convention allows the use of a generalized correlations at phase transitions. But in practice, it means that for any calculation of transport properties using these correlations, the calculated values of and will be influenced by the need to first calculate the density from and , i.e. , using an EoS, as shown in Figure 1.

Figure 1. Process flow for calculation of transport properties.
The net result is that the error in density created by the EoS propagates into the final values of the transport properties. This has several potential consequences:
Physical errors in values of and may lead to inaccurate numeric results. Because flow structure and turbulent flow regimes are often a function of Reynolds number, which is inversely proportional to , errors in transport properties may substantially change overall results.
Numeric stability and efficiency of calculations may be impacted by variations in , since CFL conditions for computational fluid dynamics are based on . This is a particular concern in simulation of sCO₂ systems, where the combination of stability criteria and the computational costs of complex equations of state can lead to wall times 3 times as long as ideal gas calculations. [5, 19]
Artificial zero or negative values of and may be theoretically possible if the combination of the error in and the sensitivity to such error of correlations for and is large enough.
This paper will focus on understanding the relationship between EoS selection and accurate prediction of transport properties. § 2 introduces terminology and describes an approach for decomposing the total error in viscosity or thermal conductivity into the error due to the choice of correlation and the error due to the choice of EoS. § 3 uses the computation of the viscosity of sCO as a test case to demonstrate this approach. Section 3 also describes the impact of viscosity and density error on the Reynolds number and on numeric stability. Section 4 presents similar results for the decomposition of thermal conductivity errors. Section 5 compares the results for supercritical CO to similar results for supercritical N and supercritical CH.
For all species and properties, the generalized EoS will be the SRK EoS and the generalized transport property correlation will be the Chung correlation. However, the approach developed in this paper is intended to be applicable to a broader set of correlations and equations of state.
Quantifying sensitivities of transport equations to EoS errors
Introducing models for computing density, viscosity and thermal conductivity
Simulations of supercritical fluids can take multiple approaches to calculating density, viscosity, and thermal conductivity. The highest fidelity can be expected for simulations of a pure species when the equation of state used is designed specifically for that species. For convenience, this density will be described as a reference density, or . The viscosity and thermal conductivity will be most accurately represented if they are computed using species-specific correlations based on :
Commonly used models for CO, N, and CH are listed in Table 1.
Table 1. Species-specific property models for representative supercritical fluids
However, as mentioned earlier, there are many situations where it is necessary to calculate the properties of mixtures. For these systems, the density must be calculated using a generalized equation of state, such as the SRK equation, to obtain the generalized density, or . The viscosity and thermal conductivity are then calculated based on the temperature and using correlations such as the Chung correlation.
Finally, a test model, where a generalized correlation is used to calculate the viscosity and thermal conductivity, but the reference density is used in the calculation, is useful in understanding potential sources of error in these calculations:
Error and Error Decomposition
Because generalized models for density, viscosity, and thermal conductivity are critical to a range of engineering calculations, it is useful to quantify both the magnitude and sources of error in their use. Quantifying errors within mixtures is challenging. However, a first estimate of errors in a mixture can be obtained by comparing the densities, viscosities, and thermal conductivities computed from the generalized property correlations with those computed from the reference correlations for each species in the mixture. For a given species, these errors can be written as:
For both viscosity and thermal conductivity, there are two sources of error. The first source of error comes from using a generalized correlation to calculate transport properties instead of a reference correlation. These errors can be written as:
A second error is introduced by the fact that the density calculated using a generalized EoS is not the same as that calculated by the reference EoS:
This error can be rewritten using Taylor series expansion of and about :
A first-order approximation of this error can be written in terms of sensitivity coefficients and , where is the partial derivative of the generalized viscosity and is the partial derivative of the generalized thermal conductivity, each with respect to density:
These two distinct sources of error can be summarized by the equations:
where and represent the higher order terms of the respective Taylor series expansions. It can be shown that and are small relative to the other sources of error, so that is well-approximated by the sum of and , and similar for .
Finally, these error decompositions can be nondimensionalized by dividing each term by the appropriate reference value:
Supercritical CO Viscosity Results: Accuracy, Kinematic Viscosity, and Stability
Viscosity Error Analysis
In many cases of engineering interest, including oxycombustion in the Allam-Fetvedt cycle and the Venusian atmosphere, sCO is the dominant component in a mixture, with relatively small amounts of trace gases. Therefore, carrying out an error analysis for sCO is likely to give an approximation of the error for the mixture. In these cases, reference viscosity values computed by using the Span–Wagner EoS and the Laesecke–Muzny correlation can be compared to those values computed by using the generalized SRK EoS and the Chung viscosity correlation.
The supercritical region, where both pressure and temperature are greater than the critical point K and atmospheres, is of particular interest. All results are shown in the region where and .
To begin, the reference density computed by the SW EoS is compared against the density computed by the SRK EoS. Figure 2 shows the reference density , the total error , and the relative error , defined as the local total error divided by the local reference density. Throughout , the SRK EoS underestimates the density by as much as relative to the SW EoS, with the most significant errors occurring in the liquid-like region, i.e. left of the Widom line.
Figure 2. CO density results. The figures shows (a) reference values for as computed by the SW EoS, (b) the signed error , and (c) the relative error . The dashed line is the Widom line.
Next, the reference viscosity is compared against the viscosity computed by the generalized property correlations.
Figure 3 presents the reference viscosity and the errors and . Viscosity is underestimated by by as much as in the liquid-like region of , while overestimates viscosity by as much as in the gas-like region, with these maximum errors occurring near the critical point.
Figure 3. CO₂ viscosity results. The figure shows (a) computed by the reference EoS and correlation, (b) the signed error , and (c) the relative error . The dashed line is the Widom line.
Comparing Figure 2(c) and Figure 3(c), the region where viscosity is underestimated by the combination of the generalized correlation and the generalized EoS roughly overlaps with the region where density is underestimated by the generalized EoS. By contrast, in the region where viscosity is overestimated, the density errors are small. This pattern reflects the decomposition of the total viscosity error into those errors caused by the use of the generalized correlation itself and those caused by the propagation of density error, as described in § 2. In particular, Figure 2 and Figure 3 suggest that the propagation of density error dominates in the liquid-like region and, likewise, that the correlation error itself dominates in the gas-like region.
To demonstrate that this is the case, Figure 4 shows , , and and , , and . Figure 4(b) shows that contributes strongly to the underestimation of viscosity in the liquid-like region, with relative error as much as . Interestingly, Figure 4(a) shows that the Chung correlation itself tends to overestimate viscosity in this same region, as well as throughout , with the strongest overestimation being in the gas-like region near the critical point. However, as expected, the propagation of density error dominates the correlation error in the liquid-like region and this explains the overall underestimation of viscosity there, while in the gas-like region the correlation error dominates leading to the overall overestimation of viscosity there. Lastly, as Figure 4(b) and (Figure 4c) shows, the linear propagation term, , dominates the higher order terms , though the effect of is offset slightly by , which has maximum relative value of 6.51% occurring in the liquid-like region.
Figure 4. CO₂ viscosity error decomposition. The top row shows the signed errors (a) , (b) , and (c) . The bottom row shows the corresponding relative errors, i.e. (d) , (e) , and (f) .
The sensitivity term quantifies the propagation of density error. Figure 5 shows the quantity . Recalling that , the plots of and , which originally appeared in Figure 2 and Figure 4 respectively, are shown again for ease of comparison. As Figure 5 shows, has the largest magnitude in the liquid-like region, meaning that the density error is largest in the same region where the generalized correlation is most sensitive to these errors. These two factors together help explain the dominance of in this region, which leads to the underestimation of in this region.
Figure 5. CO first order error factors for viscosity. Shown are (a) , (b) , and (c) .
To summarize, in the case of sCO₂, the Chung correlation overestimates viscosity and this overestimation is most pronounced in the liquid-like region. However, the SRK EoS underestimates density which contributes to an underestimation of viscosity and this effect is most pronounced in the liquid-like region. The combined effect is an overestimation of viscosity in the gas-like region, where the error from the Chung correlation dominates, and an underestimation of viscosity in the liquid-like region, where the propagation of density error due to the SRK EoS dominates.
Other EoSs, such as the Peng–Robinson EoS, will have different density errors, which may or may not have the same overall pattern. However, since the sensitivity factor is due to the Chung correlation itself, and is independent of the choice of EoS, this term is a good indicator of the sensitivity of the Chung correlation to errors in density.
Impact on Kinematic Viscosity and Reynolds Number
The kinematic viscosity , defined as the ratio of the viscosity to the density, is critical to determining the Reynolds Number of any fluid system:
where is the characteristic velocity of the system, and is the characteristic length.
The kinematic viscosity based on the reference density and viscosity will be given by:
while the kinematic viscosity computed from the generalized density and viscosity is given by:
The ratio of these two values will determine the impact on the Reynolds number:
Impacts on Numeric Stability
Numeric simulations of supercritical fluids are computationally more expensive than simulations using the ideal gas equations. This reflects both the increased computational costs of calculating fluid properties for supercritical fluids, and the need to use relatively conservative stability criteria. Both reacting [5] and non-reacting [19] simulations of sCO flows showed that the wall time needed for the same configuration increased by a factor of 3 when supercritical equations of state and transport property models were used.
The stability criteria for numeric simulations often depend on fluid properties. For instance, the maximum allowable time step for the Marker-and-Cell (MAC) methods [26], on which multiple computational fluid dynamics algorithms are built, is given by
The change in the maximum allowable time step due to errors in the density and viscosity would then be given by:
The changes in maximum allowable time step will therefore follow the pattern seen in Figure 6 of the previous section, meaning that changes in the necessary time step are likely to be on the order of 10–15 percent.

Figure 6. (a) , . CO ratio of kinematic viscosities.
The use of generalized EoSs and transport property correlations create a second possible cause of numeric instability. If the error in density is large enough, it might lead to calculation of a negative viscosity. This would lead to both unphysical results and numerical instability. The maximum allowable or to avoid a negative viscosity can be found using the Taylor expansion of about :
Setting the right hand side equal to zero and solving for the density error gives
where is a threshold value of density error near which may become negative. The corresponding is defined by dividing by the reference density. This threshold depends on the reference density, the chosen generalized viscosity correlation, and its sensitivity coefficient , but not on the generalized EoS.
Figure 7, illustrates and for the Chung correlation. For example, in the liquid-like region, an EoS that underestimates density by about 360 kg/m, i.e. that outputs a density that is about half the reference density, could cause the Chung correlation to produce negative values of viscosity. This scenario is plausible. However, in Figure 7(b), regions where are also regions where the chosen EoS would need to output negative densities in order to produce negative viscosities in the Chung correlation. If an EoS can be assumed to produce positive values of density, then density errors could only realistically lead to negative viscosity values in the liquid-like region.
Figure 7. CO floor for density error in viscosity. Shown are (a) and (b) .
Supercritical Conductivity Results
Thermal Conductivity Error Analysis
Because thermal conductivity for supercritical fluids is also calculated using correlations based on temperature and thermal conductivity, it is subject to similar errors. The total error in thermal conductivity can be decomposed in a manner similar to viscosity:
Section 3, presents results on the rectangle .
To begin, , computed by combining the SW reference EoS and the Huber–Sykioti–Assael–Perkins (HSAP) reference correlation [15] are compared against values, computed by combining the SRK generalized EoS and the Chung generalized correlation. Figure 8, presents the reference thermal conductivity and the errors and . Thermal conductivity is overestimated by throughout most of the region considered, but is underestimated in a region near the critical point. These over- and underestimations can be quite severe. The maximum overestimation is 20.61%. The maximum underestimation is , which occurs right at the critical point, though the magnitude of this underestimation rapidly reduces to an underestimation of about just away from the critical point.
Figure 8. CO thermal conductivity results. The figure shows (a) computed by the reference EoS and correlation, (b) the signed error , and (c) the relative error . The dashed line is the Widom line.
To help explain these results, Figure 9 shows , , and on a magnified subsection of near the critical point. This figure illustrates that the HSAP reference correlation includes a critical enhancement term which approximates singular behavior near the critical point, while the Chung correlation does not include such a term. As a result, drastically underestimates thermal conductivity in a small region that traces the Widom line near the critical point.
Figure 9. CO₂ thermal conductivity, zoom-in near critical point. The figure shows (a) computed by the reference EoS and correlation, (b) computed by the SRK EoS and Chung correlation, and (c) the relative error . The dashed line is the Widom line.
The decomposition of errors suggested by Equation (31) can be examined in greater detail. Figure 10 presents the errors , and . Recalling that is the portion of the error due specifically to the Chung correlation, it is clear the Chung correlation tends to overestimate thermal conductivity throughout most of , with the most extreme overestimation of 49.53% in the liquid-like region. is negative only in the small region near the critical point described in the previous paragraph, where it takes a minimum value of . This reinforces that the error in this region is due to the Chung correlation, and not due to the propagation of density error.
Figure 10. CO thermal conductivity error decomposition. The top row shows the signed errors (a) , (b) , and (c) . The bottom row shows the corresponding relative errors, i.e. (d) , (e) , and (f) .
On the other hand, the values for shown in Figure 10 demonstrate that the underestimation of density due to the SRK EoS propagates into the Chung correlation and partly offsets the overestimation due to the Chung correlation itself. is negative throughout , with a most extreme underestimation of in the liquid-like region. is responsible for only a very small amount of the error.
Indeed, by considering the sensitivity term , which represents the sensitivity of the Chung correlation to errors in density, it is clear that the Chung correlation is most sensitive to errors in density in the liquid-like region. Figure 11 plots the quantity . Recalling that , the plots of and , which originally appeared in Figure 2 and Figure 10 respectively, are repeated for ease of comparison.
Figure 11. CO first order error factors for thermal conductivity. Shown are (a) , (b) , and (c) .
Finally, Figure 12 shows against , where is computed by multiplying and . This figure shows that the first order approximation is a good approximation of the total error.
Figure 12. CO total error and first order error decomposition for thermal conductivity. Shown are (a) and (b) .
Impacts on Numeric Stability
In analogy with equation (30) from § 3.3, density errors that can potentially create negative thermal conductivities are possible, and can be quantified and avoided. Such errors are computed by:
where is a threshold value of density error near which may become negative, and the corresponding is defined by dividing by the reference density.
Figure 13 illustrates and for the Chung correlation for thermal conductivity. In the liquid-like region, an EoS that underestimates density by about 400 kg/m, i.e. by about half the reference value, could cause the Chung correlation to produce negative values of viscosity. This scenario is plausible. However, as Figure 7(b) shows, just outside the liquid-like region, such an EoS would have to produce negative values of density in order to cause the Chung correlation to produce negative values of thermal conductivity.
Figure 13. CO floor for density error in thermal conductivity. Shown are (a) and (b) .
Comparison of viscosity and thermal conductivity results
The decomposition of thermal conductivity error is similar to the decomposition of viscosity error presented in § 3. Specifically, the Chung correlation itself overestimates both thermal conductivity and viscosity throughout most of and, for both properties, the most severe overestimation occurs in the liquid-like region. At the same time, for both thermal conductivity and viscosity, the errors due to the Chung correlation are partly offset by the fact that the SRK EoS underestimates density in the liquid-like region, which is reflected in the quantities and .
For both thermal conductivity and viscosity, the Chung correlation is most sensitive to errors in density in the liquid-like region, which is precisely where the SRK EoS most severely underestimates the density. For both thermal conductivity and viscosity, in the liquid-like region it is theoretically possible for the Chung correlation to produce negative values of either property; this would require the choice of a hypothetical EoS that underestimates density by about half its reference value in this region. While the SRK EoS does underestimate density in this region, the underestimation is not so severe as to cause negative values of either viscosity or thermal conductivity.
A final similarity is that, for both thermal conductivity and viscosity, the sums and provide good approximations of the total errors and respectively. So, for both thermal conductivity and viscosity, most of the total error can be explained in terms of (1) the error produced by the Chung correlation itself, (2) the sensitivity of the Chung correlation to errors in density, and (3) the actual density error due to the choice of EoS.
On the other hand, a major difference between the error patterns for thermal conductivity compared to viscosity is that the Chung correlation also radically underestimates thermal conductivity in a small region that follows the Widom line near the critical point. The Chung correlation also underestimates viscosity near the critical point, but the underestimation is about five times less severe.
Cross-Species Results
is often considered a particularly challenging fluid to work with. So it is important to establish if the same effects appear in other fluids. This can be done by repeating the analysis for other species, such as and . To provide meaningful comparisons between these species, the same domain used in § 3 and § 4 is used for these species.
Cross-Species Density Results
Figure 14 shows for and ; for ease of comparison, this figure also reproduces for , which was originally presented in Figure 2. For each species, the SRK EoS underestimates density throughout , with the most severe underestimations of , , and for , , and respectively all occurring in the liquid-like region.
Figure 14. Relative density errors for (a) , (b) , and (c) .
Cross-Species Viscosity Results
Recalling the decomposition
Figure 15 shows , , , and for and . For ease of comparison, this figure also reproduces the similar data for , which were originally presented in Figure 3 and Figure 4. Table 2 gives maximum and minimum values for these errors in .
Figure 15. Cross-species viscosity results. Each row shows data for CO, the middle row shows data for N, and the bottom row shows data for CH.
| CO | N | CH | |
| , min | -0.1850 | -0.1824 | -0.1423 |
| , max | 0.1457 | 0.0478 | 0.0398 |
| , min | 0.0052 | -0.0727 | -0.0238 |
| , max | 0.1762 | 0.0714 | 0.0846 |
| , min | -0.3504 | -0.2148 | -0.2222 |
| , max | -2.6283e-04 | 2.7756e-04 | -8.3134e-05 |
| , min | -1.9715e-06 | -9.3180e-06 | -9.4826e-06 |
| , max | 0.0651 | 0.0215 | 0.0199 |
Table 2. Minimum and maximum viscosity errors for CO, N, and CH. Data for , , , and are given.
For all three species, the total error exhibits the same trend; i.e. viscosity is underestimated in the liquid-like region and overestimated in the gas-like region. For all three species is negative throughout . Recalling that , the trend in can be explained by the fact that the SRK EoS underestimates density for all three species (see Figure 14), while (not shown) is positive throughout for all three species, with the largest values of occurring in the liquid-like region.
On the other hand, exhibits a slightly different trend when comparing CO, N, and CH. As observed in § 3, for CO the Chung correlation itself overestimates viscosity throughout . However, for N and CH, the behavior of the Chung correlation is more complicated, with the Chung correlation itself sometimes overestimating and sometimes underestimating viscosity.
Cross-Species Thermal Conductivity Results
Figure 16 shows , , , and for N and CH and also reproduces these data for CO, which were originally shown in Figure 8 and

Figure 16. Cross-species thermal conductivity results. Each row shows , , , and for a given species. The top row shows data for CO, the middle row shows data for N, and the bottom row shows data for CH. Note that the color-scale for CO is different than for N and CH.
Table 3 gives maximum and minimum values for these quantities across .
For all three species, the Chung correlation severely underestimates thermal conductivity at the critical point. However, as Figure 16 shows, just away from the critical point, this underestimation reduces in magnitude to around .
Unlike the analogous viscosity results, the pattern in total error for thermal conductivity is not consistent across all three species. One similarity between the viscosity and thermal conductivity results is that, for all three species, is negative throughout , with the most extreme values occurring in the liquid-like region. However, the error in the Chung correlation itself, which is shown by , is quite different for the three species, leading to a different pattern in total error across the three species.
Cross-Species Kinematic Viscosity Results
The ratio is of interest for these gases as well. The minimum and maximum values of on for CO, N, and CH, as well as the values that produce these extrema; i.e. the pair is the pair that produces and similarly produces define the potential impacts of prediction of Reynolds number. These values are summarized in Table 4.
| CO | N | CH | |
| 304.1, 74.10 | 140.7, 34.18 | 501.0, 57.37 | |
| 1.000, 1.0178 | 1.114, 1.020 | 2.676, 1.264 | |
| 0.8344 | 0.9246 | 0.9124 | |
| 538.9, 72.81 | 333.7, 33.51 | 571.7, 45.39 | |
| 1.772, 1.000 | 2.644, 1.000 | 3.000, 1.000 | |
| 1.029 | 1.122 | 1.070 |
Table 4. Minimum and maximum ratios of kinematic viscosity . Shown are the minimum and maximum values of along with the temperature and pressure pairs that produce these extrema. For each temperature and pressure, both the absolute quantity and the reduced quantity are shown.
For each species, the magnitude of follows the same pattern, with throughout most of the liquid-like region and
| CO | N | CH | |
| , min | -0.9371 | -0.9370 | -0.9258 |
| , max | 0.2061 | 0.0717 | 0.0403 |
| , min | -0.9308 | -0.9303 | -0.9085 |
| , max | 0.4953 | 0.0825 | 0.0544 |
| , min | -0.3467 | -0.1419 | -0.1574 |
| , max | -4.0359e-04 | 2.8631e-04 | -6.8765e-05 |
| , min | -0.0106 | 0.0091 | -0.0090 |
| , max | 0.0112 | 3.9471e-05 | -6.3891e-06 |
Table 3. Minimum and maximum thermal conductivity errors for CO, N, and CH.
throughout most of the gas-like region, and with the transition roughly corresponding to the Widom line. See, for example, Figure 6.
In particular, for each species, is maximized in the liquid-like region somewhere along the isotherm corresponding to the critical temperature. On the other hand, it noteworthy that for CO and N the minimizer of is near the critical point while for CH this minimizer is far from the critical point. However, there is pattern here as well: for all three species, include CH, this minimizer occurs near the Widom line on the gas-like side.
Cross-Species Stability Results
and can interpreted as the smallest density errors that could cause the Chung correlation to output a negative transport property. For all three species, and throughout , indicating that for all considered temperatures and pressures a given EoS would need to underestimate density in order to produce a negative value of viscosity or thermal conductivity. Moreover, recall from the discussion in § 3.3 that a relatively small value means that a relatively small density error (e.g. an underestimation of about 50%) could cause a negative corresponding transport quantity. For each species, and , as well as the temperature and pressure pairs that produce these minima; i.e. is the pair that produces and similar for are calculated and presented in Table 5.
| CO | N | CH | |
| , | 304.1, 221.4 | 126.2, 100.5 | 190.6, 136.2 |
| , | 1.0, 3.0 | 1.0, 3.0 | 1.0, 3.0 |
| 298.1 | 305.4 | 161.3 | |
| 0.3310 | 0.5108 | 0.5832 | |
| , | 304.1, 221.4 | 126.2, 100.5 | 190.6, 136.2 |
| , | 1.0, 3.0 | 1.0, 3.0 | 1.0, 3.0 |
| 294.9 | 348.7 | 164.8 | |
| 0.3275 | 0.5832 | 0.5300 |
Table 5. Minimum magnitudes of , , , and . Shown are the minimum magnitudes of these quantities, as well as the temperatures and and pressures and that produce these minima. Note that for all species, each quantity is minimized at .
For each species, the magnitudes of both and follow the same pattern, with the least negative values in the top-left of and the most negative values in the bottom-right of . See, for example, Figure 7 and Figure 13. In particular, for all three species, both and are minimized at , where was the largest pressure considered. For all species, throughout the liquid-like region, and . Recall from the discussion in § 3.3 that these magnitudes indicate the theoretical possibility of obtaining a negative transport property while is positive. In other words, assuming that any EoS will produce positive values of density, it is nevertheless theoretically possible for all three species that an EoS could underestimate density in the liquid-like region so severely as to produce a negative value of viscosity or thermal conductivity.
The cross-species comparison shows that the issue of error propagation in use of correlations is not limited to sCO. It is likely to occur for almost any system where transport property correlations are not explicitly fit to the EoS used in the calculation.
Conclusion
These results show the key limitations of using generalized equations of state with generalized correlations for transport properties. Both generalized equations of state and generalized correlations for transport properties contain inherent errors, due to the need to fit over multiple species. The inherent curve-fit error in the transport equations can then be exacerbated by the mismatch in density created by the use of a generalized equation of state.
These effects lead to substantial challenges in interpretation of computational results for mixtures of gases at supercritical temperatures and pressures at both global and local scales within the simulation. The combined effect of errors in density and viscosity mean that the simulated system may have a Reynolds number that is ten to fifteen percent different from the Reynolds number of the physical system. These effects are then exacerbated by local errors in key transport properties. While the effect is most likely to be seen in reduced accuracy of simulation results, in extreme cases mismatch can compromise the numeric stability of the simulation either through changing the largest possible time step, as shown in equations (27) and (28), or creating negative values for transport properties.
For a simulation of only one species, the errors created by the use of a generalized equation of state and generalized transport properties, and the propogation of density errors in the transport property correlations, can be quantified by comparison with simulations that use higher-fidelity EoSs and transport property correlations. However, in the absence of high-fidelity models for mixtures, these errors cannot be quantified as effectively for simulations of mixtures, particularly reacting flow in the supercritical regions. However, there are two options that are likely to improve the accuracy of these simulations.
The first option for improving accuracy of simulations of supercritical mixtures is the co-development of generalized EoSs and transport property correlations for density, viscosity, and thermal conductivity. Once a generalized equation of state is developed, a correlation for viscosity and thermal conductivity that specifically use and as curve-fitting variables, instead of the most accurate possible value of density and , will provide the most accurate representation of the physics of the system.
The availability of machine learning tools that allow models to be fit for large data sets relatively rapidly means that accuracy can be further improved by developing combinations of equations of state and correlations of viscosity and thermal conductivity that are specific for engineering systems. In this approach, if an engineering application is known to have a set of species over a likely range of temperatures and pressures, the equation of states and transport properties correlations can be refit using only the species that are known to exist in the system, over the pressures and temperatures that are likely to exist within the system. Table 6 shows representative supercritical systems, and the species present within each system.
| Application | Species with significant mass fractions | Radicals and Trace Species |
| - , Liquid Rocket | , , | H, OH, O, |
| Methane combustion in air | , , , CO, , , NO | N, H, OH, O, , , , , , , HCO |
| Methane oxycombustion in s | , , , CO, | N, H, OH, O, , , , , , , HCO |
| Venusian atmosphere | , | , Ar, , CO, He, Ne, HCl, HF |
Table 6. Representative Multi-Species Supercritical Systems
The relative difficulty of creating these systems will vary with the application. For instance, for modeling the Venusian atmosphere, both the major species and the trace species are well-characterized, and an equation of state, viscosity correlation, and thermal conductivity correlation is available for all species. This may not be true for all systems. A bespoke approach to calculating properties for individual simulations or families of simulations does raise issues of direct comparibility of results obtained using other simulations. This may limit the viability of such an approach.
Engineering applications with fluids operating at supercritical temperatures and pressures, and the need to accurately simulate these systems, is continuing to increase. Improving the accuracy of these simulations requires re-examining how key properties calculations are implemented, and the impact of errors in these models. Ensuring consistency in EoSs and transport property calculations is a possible route towards achieving this goal.
Funding Sources
This work was authored by NLR for the U.S. Department of Energy (DOE), operated under Contract No. DE-AC36-08GO28308. Funding was provided by the Exascale Computing Project (17-SC-20-SC), a collaborative effort of two U.S. Department of Energy (DOE) organizations, the Office of Science and the National Nuclear Security Administration, and the High Performance Computing for Energy Innovation (HPC4EI) program. Mr. Fara’s participation was made possible by a fellowship from the National Science Foundation Mathematical Sciences Graduate Student Internship Program (NSF-MSGI). The research was performed using computational resources sponsored by the Department of Energy located at the National Laboratory of the Rockies. The views expressed in the article do not necessarily represent the views of the DOE or the U.S. Government. The U.S. Government retains and the publisher, by accepting the article for publication, acknowledges that the U.S. Government retains a nonexclusive, paid-up, irrevocable, worldwide license to publish or reproduce the published form of this work, or allow others to do so, for U.S. Government purposes.
Appendix
The sensitivity terms and used in this paper are the partial derivatives of or as computed by the Chung correlation with respect to . For convenience, in this Appendix, these sensitivity terms are provided.
In the Chung correlation, viscosity (in units of Poise, P) is computed as the sum
where the density-corrected kinetic term and the potential term are given by
The definition of the dilute gas viscosity (in Poise, P) can be found in [16]. The reduced density parameter , the Enskog hard-sphere correction factor , and the empirical correction factor are given by
where the symbols and have been introduced as shorthand for the expressions
Definitions of the constants , are found in [16]. The quantity is the critical volume in , is critical temperature in K, is molar density in units , and is the Lennard–Jones reduced temperature with the Boltzmann constant and the Lennard–Jones characteristic energy parameter.
Using the chain rule for partial derivatives, can be expanded as
where
Similarly, the Chung correlation computes the thermal conductivity in units of -s-K as
where
where and are as in (37) and (38) and the quantity is given by
and where the symbols and are shorthand for
The definitions of and , are found in [16]. Therefore the sensitivity factor is:
where
References
- [1]R. Span, W. Wagner, A new equation of state for carbon dioxide covering the fluid region from the triple-point temperature to 1100 k at pressures up to 800 mpa, Journal of Physical and Chemical Reference Data 25 (6) (1996) 1509–1596.DOI
- [2]U. Setzmann, W. Wagner, A new equation of state and tables of thermodynamic properties for methane covering the range from the melting line to 625 k at pressures up to 1000 mpa, Journal of Physical and Chemical Reference Data 20 (6) (1991) 1061–1155.DOI
- [3]C. Ni, X. Wang, H. Liu, K. Zhang, X. Zheng, Y. Duan, Gradient-harmonizing-based deep learning for thermophysical properties of carbon dioxide, Journal of Thermophysics and Heat Transfer 37 (2) (2023) 382–393. doi:10.2514/1.T6729.
- [4]K. A. Rivera, K. R. Anderson, M. T. Pauken, Transient thermal modeling of a venusian surface thermopile heat flux sensor, Journal of Thermophysics and Heat Transfer 37 (2) (2023) 519–522. doi:10.2514/1.T6585.DOI
- [5]M. T. Henry De Frahan, M. J. Rahimi, O. Doronina, B. A. Perry, S. Yellapantula, I. Cormier, M. Day, M. J. Martin, Simulation of methane oxycombustion in supercritical carbon dioxide, in: ASME Turbo Expo 2023: Turbomachinery Technical Conference and Exposition, 2023. doi:10.1115/GT2023-101568.DOI
- [6]J. Z. H. Wanga, R. Mével, K. Luo, J. Fan, Direct numerical simulation of turbulent counterflow diffusion ch₄/o₂ flames in a supercritical co2 environment, Journal of Supercritical Fluids 233 (2026) 106945. doi:10.1016/j.supflu.2026.106945.
- [7]Z. L. Enhui Sun, Yaru Ma, J. Xu, Aerodynamic characteristics of modular cooling wall for a 50 mw coal-fired scco2 boiler, Journal of Supercritical Fluids 225 (2026) 106712. doi:10.1016/j.supflu.2025.106712.DOI
- [8]M. Fan, X. Zhang, Y. Zhang, H. Wang, H. Wang, Y. Lu, Numerical assessment of scale-up criteria in a wall-cooled reactor for hydrogen combustion in supercritical water, Journal of Supercritical Fluids 232 (2026) 106919. doi:10.1016/j.supflu.2026.106919.DOI
- [9]X. Zhang, S. Heinonen, E. Levänen, Applications of supercritical carbon dioxide in materials processing and synthesis, RSC Advances 4 (105) (2014) 61137 – 61152. doi:10.1039/c4ra10662h.DOI
- [10]C. Aymonier, G. Philippot, A. Erriguible, S. Marre, Supercritical and Other High-pressure Solvent Systems: For Extraction, Reaction and Materials Processing, The Royal Society of Chemistry, 2018, Ch. Materials Processing and Recycling with Near-and Supercritical CO2-based Solvents, pp. 304–339.
- [11]E. G. Rasmussen, J. Kramlich, I. V. Novosselov, Scalable continuous flow metal-organic framework (mof) synthesis using supercritical co2, ACS Sustainable Chemistry and Engineering 8 (26) (2020) 9680 – 9689. doi:10.1021/acssuschemeng.0c01429.DOI
- [12]G. Soave, Equilibrium constants from a modified redlich-kwong equation of state, Chemical engineering science 27 (6) (1972) 1197–1203.DOI
- [13]D.-Y. Peng, D. B. Robinson, A new two-constant equation of state, Industrial & Engineering Chemistry Fundamentals 15 (1) (1976) 59–64.DOI
- [14]A. Laesecke, C. D. Muzny, Reference correlation for the viscosity of carbon dioxide, Journal of physical and chemical reference data 46 (1) (2017).DOI
- [15]M. L. Huber, E. Sykioti, M. J. Assael, R. A. Perkins, Reference correlation of the thermal conductivity of carbon dioxide from the triple point to 1100 k and up to 200 mpa, Journal of physical and chemical reference data 45 (1) (2016).pubmed.ncbi.nlm.nih.gov/27064300
- [16]T. H. Chung, M. Ajlan, L. L. Lee, K. E. Starling, Generalized multi-parameter correlation for nonpolar and polar fluid transport properties, Industrial & engineering chemistry research 27 (4) (1988) 671–679.
- [17]M. J. Martin, E. G. Rasmussen, S. Yellapantula, Nonlinear heat transfer from particles in supercritical carbon dioxide near the critical point, Journal of Thermal Science and Engineering Applications 12 (2019) 1948–5085. doi:10.1115/1.4045222.
- [18]E. Rasmussen, S. Yellapantula, M. J. Martin, How equation of state selection impacts accuracy near the critical point: Forced convection supercritical co2 flow over a cylinder, The Journal of Supercritical Fluids 171 (2021) 105141. doi:https://doi.org/10.1016/j.supflu.2020.105141.
- [19]A. Ameli, A. Afzaliafar, T. Turunen-Saaresti, J. Backman, Effects of real gas model accuracy and operating conditions on supercritical co2 compressor performance and flow field, Journal of Engineering for Gas Turbines and Power 6 (140) (2018) 062603. doi:doi.org/10.1115/1.4038552.
- [20]R. Span, W. Wagner, A new equation of state for carbon dioxide covering the fluid region from the triple-point temperature to 1100 k at pressures up to 800 mpa, Journal of physical and chemical reference data 25 (6) (1996) 1509–1596.DOI
- [21]R. Span, E. W. Lemmon, R. T. Jacobsen, W. Wagner, A. Yokozeki, A reference equation of state for the thermodynamic properties of nitrogen for temperatures from 63.151 to 1000 k and pressures to 2200 mpa, Journal of Physical and Chemical Reference Data 29 (6) (2000) 1361–1433.DOI
- [22]E. W. Lemmon, R. T. Jacobsen, Viscosity and thermal conductivity equations for nitrogen, oxygen, argon, and air, International journal of thermophysics 25 (2004) 21–69.DOI
- [23]U. Setzmann, W. Wagner, A new equation of state and tables of thermodynamic properties for methane covering the range from the melting line to 625 k at pressures up to 1000 mpa, Journal of Physical and Chemical reference data 20 (6) (1991) 1061–1155.DOI
- [24]S. E. Quiñones-Cisneros, U. K. Deiters, Generalization of the friction theory for viscosity modeling, The Journal of Physical Chemistry B 110 (25) (2006) 12820–12834.
- [25]D. G. Friend, J. F. Ely, H. Ingham, Thermophysical properties of methane, Journal of Physical and Chemical Reference Data 18 (2) (1989) 583–638.DOI
- [26]F. H. Harlow, J. E. Welch, Numerical calculation of time-dependent viscous incompressible flow of fluid with free surface, Physics of Fluids 8 (1965) 2182–2189. doi:10.1063/1.1761178.DOI