betaFeedback

WorksPhysics and Astronomy

Graphene-enabled coherent (sub-)terahertz wave detection and thickness determination

Abstract

Phase-sensitive terahertz (THz) detection enables applications ranging from astronomy to non-destructive testing. However, current THz detectors lack phase sensitivity, unless they are combined with external interferometers, or through photomixing. This implies a large footprint and sensitive dependence on alignment. Here, we demonstrate a graphene-enabled, on-chip, integrated (sub-)THz detector-interferometer with optical cavity and antenna, exhibiting high sensitivity to the phase of incident THz light. We exploit this by determining the thickness of thin films placed in front of the detector-interferometer, obtaining a deep sub-wavelength thickness accuracy of a few micrometer, while we predict that an improved accuracy is within reach. This is relevant for a range of industrial application domains, including automotive, construction, and health. We furthermore achieve a record-high external responsivity - considering bias-free graphene-based (sub-)THz detectors - of 172 mA/W and a noise-equivalent power of 26 pW Hz−1/2~\rm{Hz}^{-1/2}. This performance is due to enhanced absorption at the resonant cavity mode around 89 GHz, in agreement with multi-physics simulations. These results pave the way to exploiting coherent wave detection in the (sub-)THz regime with utility in spectroscopy, next-generation wireless communication, and beyond.

coherentDetection_Arxiv_v2.pdf

Introduction

Coherent wave detection, which exploits phase information instead of the amplitude or intensity of incident light, is an essential tool that lies at the core of many scientific and engineering fields. A common way to implement coherent wave detection is through wave interference [1, 2]. Phase-sensitive detectors and interferometers in the THz regime are particularly desirable for a wide range of applications, where the use of more conventional electromagnetic spectrum ranges is limited [3, 4]. For example, in astronomy, the detection of specific cosmic THz radiation allows diving into the formation of planets and galaxies in the far regions of the Universe [5, 6, 7]. Coherent THz detection also reinforces security applications [8, 9, 10] and non-destructive testing in the automotive, building and construction, and electronics industries. A prime example is the determination of the thicknesses of thin, visible-opaque coatings and films, such as car paint layers [11, 12, 13, 14]. Coherent THz detection can also lead to a speed-up of wireless telecommunication systems [15, 16], where phase-sensitive data transfer schemes are combined with a high-frequency carrier wave [17], and in quantum key distribution systems [18, 19].

In the most common coherent THz detection approaches, the amplitude and phase of weak THz signals are measured through heterodyne and homodyne detection [7, 20, 21, 22]. This is the case for THz time-domain spectroscopy, where THz pulses are detected through electro-optic sampling in non-linear crystals followed by balanced photodetection [23, 24, 25]. This is also the case for continuous wave THz spectroscopy using photomixers [26, 27]. Coherent THz detection through interferometry typically relies on external optical setups, such as Michelson and Fabry-Pérot interferometers, after which a photodetector registers the interference pattern of the mixed waves [28, 29]. These approaches have a large footprint, significant power consumption, and a rather high cost, while being sensitive to (mis)alignment. A chip-sized, heterodyne-free THz detector with phase sensitivity would overcome these issues.

Here, we introduce an on-chip integrated graphene (sub-)THz detector that is simultaneously an interferometer through its combination with a vertical (sub-)THz cavity that is formed between a metallic antenna and a metallic back mirror (see Figure 1). We demonstrate that the absorption enhancement in the cavity, together with the strong photo-thermoelectric response of graphene, gives rise to an external responsivity of 172 mA/W and an external noise-equivalent power of 26 pW Hz−1/2^{-1/2}. The detector does not require any bias voltage, resulting in minimal power consumption. Because of the large responsivity, the interference effects in the internal cavity, the external emitter-detector cavity, and the ultrathin photoactive layer formed by the graphene, this integrated (sub-)THz detector-interferometer enables highly phase-sensitive (sub-)THz photodetection, with a phase sensitivity below 0.02 rad. We demonstrate the utility of this phase sensitivity by determining the thickness of optically opaque materials, in particular silicon, paper, kapton, and polypropylene. The thickness accuracy we achieve is a few micrometers, which is three orders of magnitude smaller than the wavelength. This accuracy can be improved to the nanometre regime by increasing the THz power and phase stability of the source. Beyond thickness determination, this coherent THz detector-interferometer opens up a myriad of possibilities for technologically relevant applications, for example wireless communications relying on phase-encoded protocols.

Image not extracted

Figure 1. Schematic of the integrated graphene-based (sub-)THz detector-interferometer. The device contains hBN-encapsulated graphene underneath a dipolar antenna. The photo-active region is the graphene channel below the gap of the dipolar antenna. This channel has side contacts (not shown) that enable us to measure photocurrent. The antenna and the metallic back mirror form an optical cavity, where incident (THz) light can travel back and forth and interfere. The (sub-)THz cavity consists mostly of silicon.

Results

Device and signatures of interference

We fabricated four graphene-based detectors that include a built-in vertical optical cavity, which leads to multiple reflections and constructive and destructive wave interference. The choice for graphene is based on its large Drude absorption [30, 31] and the promising THz photodetection performance that has recently been demonstrated [32, 33, 34, 35, 36, 37, 38]. The atomically thin photoactive region furthermore minimizes the broadening of interference peaks. We optimized the detector specifically for the photothermoelectric effect, which simultaneously offers high sensitivity, fast response, broad spectral response, and passive operation [39, 40, 41, 42, 43, 44, 45]. The detectors contain a dipolar antenna that funnels (sub-)THz radiation to the photoactive graphene area, and its two branches serve as electrostatic gates to create a junction in the graphene channel [39, 46]. The antenna also serves as one of the two reflecting surfaces of the optical cavity, while the other surface consists of a metallic back mirror. In between the two reflecting surfaces, there is mainly silicon with a thickness of 279 μ\mum, in addition to hBN-encapsulated graphene, which is directly below the antenna, as shown in Figure 1 (see Methods and Supp. Fig. S1 for details). All the results in the main text belong to Device 1, unless explicitly stated. Supplementary Figs. S12-13 show the results obtained from Devices 2-4.

We first characterize our device by measuring the photocurrent IPTEI_{\mathrm{PTE}} as a function of frequency ff using a commercial continuous-wave THz setup (see Methods). The results in Figure 2a show a strong photocurrent peak at fpeak=89f_{\mathrm{peak}} = 89 GHz, corresponding to a free-space wavelength of λ0=3.35\lambda_0 = 3.35 mm. We ascribe this to positive interference at the location of the photoactive graphene area, which occurs for a cavity with a length LL equal to λ04nTHz\frac{\lambda_0}{4n_{\mathrm{THz}}} (see Supp. Fig. S2 for details). This gives a THz refractive index of nTHz=3.1n_{\mathrm{THz}} = 3.1, which is close to the expected refractive index of silicon of around 3.5 in the THz range [47]. Examining the width of the photocurrent peak fwidthf_{\mathrm{width}}, we extract a quality factor of Q=fpeak/fwidth=74Q = f_{\mathrm{peak}}/f_{\mathrm{width}} = 74 for the internal cavity formed between the metallic antenna and the metallic back mirror. In addition to the main photocurrent peak, we observe periodic peaks around the central frequency. We attribute these to the external cavity that is formed between the detector and the THz source, as shown in Figure 2b. We will discuss this in more detail in the subsection that describes the finite-difference time-domain simulations.

Image not extracted

Figure 2. a, Measured photocurrent as a function of frequency ff (wavelength λ0\lambda_0), where a main peak occurs at 89 GHz (3.35 mm). The inset presents a zoom of the main peak with a Lorentzian fit (dotted black line). b, Schematic of the relevant internal and external cavities. The photocurrent peak corresponds to the situation where reflections in the internal cavity lead to constructive interference at the graphene location. The thinnest cavity for which this occurs is when L=λ04nTHzL = \frac{\lambda_0}{4n_{\mathrm{THz}}}. c, Measured photocurrent at 89 GHz while moving the detector along the light propagation direction xx. The oscillatory pattern has a maximum (minimum) at position xmax⁡x_{\max} (xmin⁡x_{\min}), with ∣xmax⁡−xmin⁡∣=λ0/4\lvert x_{\max} - x_{\min}\rvert= \lambda_0/4. d, Schematic of the experimental geometry when moving the detector in the xx-direction. Maxima (minima) occur when the incident field at the graphene position has a maximum (minimum). e, Measured photocurrent as a function of frequency in the near-infrared (NIR) range, showing periodic oscillations with maxima fmax⁡f_{\max} and minima fmin⁡f_{\min}. f, Representation of the interference conditions at telecom frequencies, where the frequency spacing is determined by the internal cavity via ∣fmax⁡−fmin⁡∣=c/4nNIRL\lvert f_{\max} - f_{\min}\rvert= c/4n_{\mathrm{NIR}}L.

To further study interference effects in our device, we map the occurrence of constructive and destructive interference by moving the detector position along the THz propagation axis (out-of-plane direction xx, see Figure 1) for incident light at 89 GHz, see Figure 2c. The result looks like a typical interferogram with maxima and minima. The periodicity of the signal is 1.79 mm (see Supp. Fig. S3), which is very close to λ0/2\lambda_0/2. For incident light with a frequency of 160 GHz, we observe a similar interference pattern, now with a periodicity of 0.98 mm, which is again very close to λ0/2\lambda_0/2 (see Supp. Fig. S3). We therefore ascribe the observation of the occurrence of maxima and minima in photocurrent to the occurrence of maxima and minima in the intensity of the electric field of the incident (sub-)THz light at the graphene position, as shown in Figure 2d. This confirms that our detector works as an interferometer.

As final evidence of interference, we measure the photocurrent response using a tunable telecom laser in the wavelength range between 1549 and 1554 nm (see Supp. Fig. S4). Figure 2e shows clear oscillations with a frequency spacing around Δf=80\Delta f = 80 GHz, where the frequency spacing of the oscillations matches the constructive (fmax⁡f_{\max}) and destructive (fmin⁡f_{\min}) interference conditions at the graphene position, due to the internal cavity, in the near-infrared (NIR) regime. This is given by

Δf=∣fmax⁡−fmin⁡∣=c4nNIRL,\Delta f = \lvert f_{\max} - f_{\min} \rvert= \frac{c}{4n_{\mathrm{NIR}}L},

where cc is the speed of light and nNIRn_{\mathrm{NIR}} the refractive index of silicon in the near-infrared. This gives a refractive index of 3.3, which is close to the reported values [47] (see Supp. Fig. S4 for details). This shows that the internal cavity leads to interference effects over a broad range of frequencies, spanning at least from 80 GHz to 200 THz.

Enhanced sensitivity of combined THz detector-interferometer

Having reported evidence of interference occurring in our (sub-)THz detector due to a built-in optical cavity, we explore how this enhances the performance of the detector in terms of responsivity and noise-equivalent power. Figure 3a shows the measured photocurrent vs.vs. the incident THz power PinP_{\mathrm{in}}. The slope gives an external device responsivity of Rext=IPTE/Pin=73R_{\mathrm{ext}} = I_{\mathrm{PTE}}/P_{\mathrm{in}} = 73 mA/W (36 V/W). Considering Johnson noise as the main noise source, this gives an external noise-equivalent power (NEPext\mathrm{NEP}_{\mathrm{ext}}) of 79 pW Hz−1/2^{-1/2} for Device 1 (see Methods). Device 4 gives a responsivity of 172 mA/W and an NEP of 26 pW Hz−1/2^{-1/2}, which we ascribe to a more optimal graphene channel geometry with a width of 3 μ\mum instead of 30 μ\mum (see Supp. Figs. S12-Supplementary Figure 13). These numbers are not corrected for the amount of THz absorption or the ideal case of a diffraction-limited spot size, which means that they are truly external performance parameters without any normalization. In terms of external responsivity and NEP, our detector outperforms all bias-free, graphene-based photodetectors in the (sub-)THz regime published to date (see Supp. Fig. S6).

Enhanced responsivity and absorption from experiment and simulation

Figure 3. Enhanced responsivity and absorption from experiment and simulation. a, Measured photocurrent IPTEI_{\mathrm{PTE}} at 89 GHz vs. incoming THz power PinP_{\mathrm{in}}, giving an external responsivity of 73 mA/W. b, Simulation of the (sub-)THz absorption η\eta vs. frequency for incident THz light that is focused with a numerical aperture of 0.5, as in the experiment. The absorption gives a peak value due to interference in the internal cavity (blue curve), in agreement with the experimental results of Figure 2a. Additional enhancement occurs due to the external cavity (grey curve), which gives rise to a substructure that is shown in the inset. c,d, Maps of the electric field intensity ∣ETHz∣2\lvert E_{\mathrm{THz}}\rvert^2 (c) and absorption density (d) as a function of frequency and lateral position yy, along the source-drain direction. These maps show strong enhancement inside the gap of the dipolar antenna around the resonance frequency. The dashed lines indicate the gap of the dipolar antenna with width wgapw_{\mathrm{gap}}.

External responsivity of four (sub-)THz interferometers

Supplementary Figure 13. External responsivity of (sub-)THz interferometers. We determined the external responsivity RextR_{\mathrm{ext}} of the four different devices and used graphene channel resistances of (a) 500 Ω\Omega, (c) 1031 Ω\Omega and (d) 830 Ω\Omega to obtain the NEP, achieving the lowest NEP of 26 pA/Hz\sqrt{\mathrm{Hz}} for Device 4 in panel d.

The large responsivity of the detector could be due to a long cooling time τcool\tau_{\mathrm{cool}} of hot carriers in graphene, or due to strong THz absorption. To explore the first hypothesis, we determine the cooling time by performing time-resolved photocurrent measurements (see Methods, and Supp. Fig. S7). We extract a mean cooling time around 3.4 ps, which is a typical value for hot carrier cooling in hBN-encapsulated graphene [48, 49]. From the experimentally determined photocurrent and cooling time, we estimate a THz absorption coefficient η\eta of 20% for our THz focus spot (see Methods). This large absorption is the combined result of the antenna, the internal cavity, and the external cavity, as we show in the next section. Importantly, this is the absorption for the case of the experimental, non-diffraction-limited focus area AfocusA_{\mathrm{focus}}. It is common practice to extrapolate the performance of (THz) photodetectors to the situation for a diffraction-limited spot with area AdiffA_{\mathrm{diff}} by multiplying the responsivity by Afocus/Adiff≈13A_{\mathrm{focus}}/A_{\mathrm{diff}} \approx13. Interestingly, our detector already absorbs so strongly that such an extrapolation would result in a nonphysical absorption above 100%.

Simulations of absorption and responsivity

To support our experimental findings, we simulate the photoresponse of our device using finite-difference time-domain simulations (see Methods for details). We simulate the spectral response in terms of absorption in the graphene layer and the device responsivity in two cases: i)i) considering the internal cavity only, and ii)ii) including both the internal and external cavities. The results in Figure 3b show that the internal cavity increases the graphene (sub-)THz absorption by one order of magnitude (see also Supp. Fig. S3). By adding the external cavity, the total absorption in the graphene channel increases by another factor of three, reaching a maximum of 15%. This is very close to the 20% obtained from the measured photocurrent and cooling time. Furthermore, we extract Rext=24\mathbb{R}_{\mathrm{ext}} = 24 mA/W from the simulation with only the internal cavity, and Rext=120\mathbb{R}_{\mathrm{ext}} = 120 mA/W by including internal and external cavities, as shown in Supp. Fig. S3. This is close to the experimentally obtained value of Rext\mathbb{R}_{\mathrm{ext}} of 73 mA/W for Device 1.

The inset of Figure 3b shows the effect of the external cavity formed between the THz source and the detector-interferometer, which is the appearance of additional maxima and minima in absorption. The periodicity of this substructure is determined by the source-detector distance. We observe this substructure also in the experimental photocurrent data, as shown in the inset of Figure 2a. Indeed, Fourier analysis of the experimental photocurrent spectrum for two different source-detector distances reveals the periodicity of the additional peaks around the resonant frequency. This periodicity matches the spectral substructure found in the simulations (see Supp. Fig. S3). Thus, the interference in the internal cavity mainly leads to enhanced responsivity for (sub)THz radiation, while the external cavity mainly gives rise to the observed interference pattern.

In addition to internal and external cavities, the device also contains a dipolar antenna that enhances the absorption in the graphene channel, as demonstrated earlier [39]. To observe its effect, we simulate the (sub-)THz field intensity and absorption density along the graphene channel at different frequencies, see Figure 3c,Figure 3d. The distribution of the (sub-)THz field intensity on the device surface demonstrates the funnelling of THz light into the antenna gap. Because the graphene channel is located directly below this gap, this leads to strong (sub-)THz absorption enhancement and therefore to a large device responsivity. In Supp. Fig. S3, we summarize the relative contributions to the absorption enhancement from the antenna, the internal cavity, and the external cavity.

Quantifying the phase sensitivity

Having established that the (sub-)THz detector has a high sensitivity and acts as an interferometer, we now quantify its phase sensitivity. We first describe the obtained interference patterns quantitatively, for which we use an Airy function that is typical for a Fabry-Pérot cavity (see Supp. Info. Section S8 for details). This gives good agreement for the experimentally obtained and simulated interference patterns, with coefficients of finesse of ∼0.05\sim0.05 and ∼2\sim2, respectively (see Supp. Fig. S16). We next determine a spatial sensitivity ∂IPTE/∂x\partial I_{\mathrm{PTE}}/\partial x of 370 nA/mm by performing the numerical derivative in Figure 2c. Since the phase φ\varphi is related to the spatial position xx via φ=2πx/λ0\varphi= 2\pi x/\lambda_0, the phase sensitivity follows from ∂IPTE∂φ=∂IPTE∂x⋅∂x∂φ=200\frac{\partial I_{\mathrm{PTE}}}{\partial\varphi} = \frac{\partial I_{\mathrm{PTE}}}{\partial x} \cdot\frac{\partial x}{\partial\varphi} = 200 nA/rad (see Supp. Info. Section S8 for details). We define the zero-point of the phase as the point halfway between a peak and a dip in the interference pattern, which is the point with the largest phase sensitivity. Using this definition, we can distinguish phases between −π/4-\pi/4 and +π/4+\pi/4.

To determine the minimum detectable phase δφ\delta\varphi, we use δφ=(∂IPTE/∂φ)−1Inoise\delta\varphi= \left(\partial I_{\mathrm{PTE}}/\partial\varphi\right)^{-1} I_{\mathrm{noise}}, where InoiseI_{\mathrm{noise}} is the noise current. We experimentally determine this to be 3.6 nA3.6\ \mathrm{nA} (see Supp. Fig. S18). This gives a phase sensitivity of δφ=0.018 rad\delta\varphi= 0.018\ \mathrm{rad} (=1∘=1^\circ). If the noise would be limited by the detector, we would obtain a Johnson noise current of 4 pA4\ \mathrm{pA}, which would lead to a phase accuracy of 0.02 mrad0.02\ \mathrm{mrad}. We don’t achieve this, because we are limited by the frequency stability of the source, rather than the detector noise. The reason is that the phase and frequency of the THz source are related to each other via the external cavity via φ=πLf/c\varphi= \pi Lf/c, where LL is the distance between the THz source and the detector [50]. In order to quantify the frequency stability, we measure the photocurrent while sweeping the frequency in a small frequency region at different times (see Supp. Fig. S19) and obtain frequency fluctuations of ≈5 MHz\approx5\ \mathrm{MHz}. This corresponds to phase noise of ≈0.02 rad\approx0.02\ \mathrm{rad}, similar to the experimentally obtained one. This confirms that the minimum detectable phase is currently limited by the stability of the THz source. Importantly, our approach forms a complete, traceable and uncertainty-bounded framework for phase determination.

Using phase sensitivity for thicknesses determination

Finally, we exploit the phase sensitivity to determine the thickness of thin films. In order to do so, we measure the generated photocurrent while moving the detector along the out-of-plane direction xx, with and without a thin sample material placed between the THz source and our (sub-)THz detector-interferometer, as shown in Figure 4a. Since the sample material has a (sub-)THz refractive index nsn_s, this gives rise to a spatial shift Δx\Delta x in the interference pattern. From this spatial shift, we extract the thickness of the sample dd using: Δx=(ns−nair)d\Delta x = (n_s - n_{\mathrm{air}})d with nair=1n_{\mathrm{air}} = 1.

Updated figure panels d and e Thickness determination using coherent THz detector-interferometer

Figure 4. Updated figure panels d and e Thickness determination using coherent THz detector-interferometer. a, Scheme of the THz thickness determination measurements, where the spatial shift Δx\Delta x is related to the thickness dd of the material placed between the THz source (left) and detector (right). b, Simulation of the absorption in the graphene channel, while moving the detector along the direction of the wave propagation, for the case that a material with ns=1.6n_s = 1.6 is placed between the THz source and the detector. The black dashed line shows the maximum absorption of the graphene depending on the thickness of the material dd. The slope is equal to (ns−nair)(n_s - n_{\mathrm{air}}). The intersection between the blue and black dashed line represents the position of maximum absorption for a thickness of 100 μ\mum. The spatial shift Δx\Delta x is the distance between the position of the intersection and the position where there is no sample, i.e. d=0d = 0. c, Photocurrent IPTEI_{\mathrm{PTE}} interference patterns (y axis offset for clarity) vs. position xx, measured for three combinations: thin films of silicon, paper and kapton (blue), each combined with a reference measurement without sample (red). The spatial shift Δx\Delta x in the interference pattern is the result of the phase delay induced by the higher refractive indices of the samples compared to air. d, Extracted thicknesses dd for silicon, paper, kapton, and polypropylene (PP) films (blue markers) vs. expected thicknesses d∗d^*. The error bars represent the 68% confidence interval. e, Determination of the thickness accuracy δd\delta d vs. refractive index nsn_s in the experimental case (solid line). The dashed line shows the ideal thickness accuracy for a phase-stable source, where the photocurrent noise is only limited by Johnson noise.

We confirm the validity of this approach by simulating the absorption in graphene when moving along the xx-position. We use the case where a material of thickness dd and refractive index ns=1.6n_s = 1.6 (for paper) is placed between the source and the detector. The results in Figure 4b show that maximum absorption occurs for specific combinations of thickness dd and position xx. These maxima occur with a periodicity of λ0/2\lambda_0/2 and satisfy the relation ∂x∂d=(ns−nair)\frac{\partial x}{\partial d} = (n_s - n_{\mathrm{air}}). This simulation confirms that our experimental approach to determine sample thicknesses is valid.

Figure 4c shows the results of the phase-enabled thickness measurements on three different materials widely used in industrial sectors: a high-resistive double-side polished Si wafer (Si, ns≈3.5n_s \approx3.5 [47]), paper (ns≈1.6n_s \approx1.6 [51]), and a Kapton polyimide thin film (ns≈1.8n_s \approx1.8 [52]). In all cases, the oscillating pattern is displaced by a spatial shift Δx\Delta x between the case without and the case with the sample. The shift depends on the thickness and refractive index of the inset material. The thicknesses we obtain are consistent with the independently determined thickness values, as shown in Figure 4d (see Methods for details). This also includes a measurement of a polypropylene (PP) film with a thickness of 40 μm\mu\mathrm{m} and refractive index of 1.5 [53] (see Supp. Fig. S9).

The precision of the thickness measurement depends on how much the photocurrent changes due to a change in the thickness of the material with a certain refractive index, compared to the smallest observable change in the photocurrent:

δd=(∂IPTE∂x)−1×Inoise(ns−1)\delta d = \left(\frac{\partial I_{\mathrm{PTE}}}{\partial x}\right)^{-1} \times\frac{I_{\mathrm{noise}}}{(n_s-1)}

Figure 4d shows the calculated thickness accuracy as a function of the refractive index, which closely matches the thickness error bars that we obtained experimentally for the four different materials that we studied. We obtain the highest accuracy for silicon, which is a few micrometers. We haven taken the refractive index of the samples as given. In case of uncertainty in the refractive index δns\delta n_s, the error will propagate as δd/d=δns/(ns−1)\delta d/d = \delta n_s/(n_s - 1).

If the photocurrent noise were limited by Johnson noise, we would reach a thickness accuracy close to 10 nm, which is six orders of magnitude smaller than the wavelength. This requires a sufficiently phase- and power-stable THz source, faster scanning of the detector position, and potentially packaging of the detector to minimize electronic noise. A more intense THz source could lead to a further improvement in thickness accuracy.

Discussion

In conclusion, we have added the capability of phase sensitivity to (sub-)THz detectors by developing a chip-scale, integrated (sub-)THz detector-interferometer with high responsivity and high sensitivity to the phase of the incident (sub-)THz light. This is enabled by combining the strong photo-thermoelectric response of graphene with a planar THz dipolar antenna and a vertical optical cavity. We have demonstrated interference effects in the spectral, spatial, and temporal domain, and for both (sub-)THz and near-infrared light. Finally, we have exploited the phase sensitivity to determine the thickness of thin films with deep sub-wavelength accuracy. The main advantages of our integrated detector-integrator concept are i) its very low power consumption, as the device is passive, in particular not requiring any bias voltage; ii) its compactness; iii) its operation with continuous-wave light, rather than femtosecond pulsed light; and iv) its broadband operation that is only limited by the antenna and the internal cavity, and not by the photo-active material. This makes the graphene-based detector-interferometer a promising alternative to THz time-of-flight measurements using femtosecond pulses, aimed at determining film thicknesses, for example.

While our optical cavity led to the largest absorption enhancement and phase sensitivity for light around 80-90 GHz, it is possible to optimize the optical cavity for other frequencies, or to incorporate a tunable cavity [37]. The cavity resonances also repeat for any integer of wavelengths in the cavity. Replacing the dipolar antenna by a broadband antenna, such as a bow-tie or log-spiral antenna, also broadens the applicable wavelength range. Finally, we note that for several applications only a single-pixel detector is required, which means that scalable device fabrication, for example via growth based on chemical vapor deposition, is not a strict prerequisite for applicability. Beyond thickness measurements, the phase sensitivity of our (sub-)THz detector-interferometer opens up a myriad of possibilities to exploit phase information, including non-destructive industrial testing, beyond-fifth-generation wireless data transfer, and quantum technologies.

Materials and methods

Device fabrication. The starting point of the fabrication of Device 1 was a highly resistive double-side polished silicon substrate with a thickness of 279 μm279\,\mu\mathrm{m}, with thermally grown SiO2\mathrm{SiO_2} of thickness 300 nm300\,\mathrm{nm} on both sides. We placed hBN-encapsulated graphene on top, and contacted the graphene to source and drain electrodes via side contacts using etching and metal evaporation. The graphene channel has a width of wdev=30 μmw_{\mathrm{dev}} = 30\,\mu\mathrm{m}. We deposited a dipolar antenna on top of the hBN-graphene-hBN stack. The antenna has a gap width wgapw_{\mathrm{gap}} of 300 nm300\,\mathrm{nm}, a width wantw_{\mathrm{ant}} of 30 μm30\,\mu\mathrm{m}, and a length LantL_{\mathrm{ant}} of 681 μm681\,\mu\mathrm{m}. The substrate with graphene, contacts, and antenna was placed on a metal support, forming the back mirror. We note that Device 1 has been measured over the course of three years and across three different countries with good reproducibility. Devices 2-4 were fabricated using a polished silicon substrate with a thickness of 525 μm525\,\mu\mathrm{m}, with a 100 nm100\,\mathrm{nm} layer of Al2O3\mathrm{Al_2O_3} grown using atomic layer deposition. We first spin-coated a photolithography resist to protect the top side of the wafer, then we evaporated 5 nm5\,\mathrm{nm} of Ti and 50 nm50\,\mathrm{nm} of Au on the back side of the wafer to create the back metallic mirror. We next dissolved the photoresist using acetone and performed a post-clean process using oxygen plasma. We placed hBN-encapsulated graphene on the top side of the wafer and contacted the graphene as we described for Device 1. We used a channel length of 1 μm1\,\mu\mathrm{m} for Devices 2-4, and a width of 1 μm1\,\mu\mathrm{m} for Devices 2-3 and 3 μm3\,\mu\mathrm{m} for Device 4. We next placed a layer of 3030 nm of hBN using dry transfer technique, and then we patterned a bow-tie antenna on top with a gap of 300 nm using electron beam lithography.

Terahertz photocurrent setup. The terahertz photocurrent setup is based on a “Terascan 1550” continuous wave terahertz spectroscopy system [54] (Toptica Photonics AG), which has an accessible range from 0 to 1.2 THz, with a THz power around 7.6 µW at 89 GHz. Power calibration curves are available in Supp. Fig. S10. The divergent THz beam generated on the source side of the commercial THz setup is collimated using a first parabolic mirror and then focused onto the graphene-based detector-interferometer by a second parabolic mirror. Both parabolic mirrors have a focal distance of 50.8 mm and a diameter of 50.8 mm, corresponding to a numerical aperture (NA) of 0.5. The sample is mounted on a motorized xyzxyz-stage, whose maximum range along one axis is 25 mm and minimal step resolution of 1.25 µm. We collect the demodulated photocurrent via a lock-in amplifier (Zurich Instruments MFLI). The reference frequency to perform the lock-in detection is based on the AC bias applied to the THz source (39.7 kHz). All measurements are performed with VgA=VgB=0V_g^A = V_g^B = 0 V. For the THz thickness measurements, the samples of interest (Si wafer, paper, Kapton, polypropylene film) are placed close to the THz focal point in front of the graphene-based detector-interferometer. In all measurements, a polystyrene foam is placed in the collimated beam path to absorb any remaining non-THz light that was used to generate THz radiation. An illustration of the setup is depicted in Supp. Fig. S10.

Time-resolved photocurrent setup. We use a femtosecond laser (≃100\simeq100 fs pulse duration, 76 MHz repetition rate, 1030 nm central wavelength) split into two pump beams to excite the device. We modulate one of these pump beams at 240 Hz using a mechanical chopper. This beam passes through a mechanical delay line that controls the time delay τdelay\tau_{\mathrm{delay}} between both pump pulses. For both pump beams, we adjust the power at the sample location to a few hundreds of µW. We set the polarization of the pump beams perpendicular to each other. We combine both beams using a non-polarizing beam splitter, and a 50x objective (NA = 0.42) focuses the beams onto the photo-active region of the graphene-based detector-interferometer, with typical spot sizes of ≃1 μm\simeq1\,\mu\mathrm{m}. We use closed-loop xyzxyz-nanopositioners to move the sample with respect to the laser beams. We collect the generated photocurrent from the device using lock-in detection by demodulating the signal at the chopper frequency. Additionally, we can collect the reflected probe light using a biased InGaAs photodetector to simultaneously obtain reflectance and photocurrent maps of the device. For the time-resolved photocurrent measurements, we scan the delay line to achieve a time delay window of ±30\pm30 ps, with sub-ps temporal resolution. We perform all measurements under ambient conditions without applying any gate voltage to the device. An illustration of the setup is shown in Supp. Fig. S10. To extract the cooling time, we fit the photocurrent signal as a function of delay time to exponentially decaying functions.

Photoresponse simulations. We perform all the simulations using Lumerical software. We first simulate the frequency response of the cavity using a 2D model with a plane wave for three cases: i) without a back mirror, ii) with back mirror, iii) including a Si lens in the point source. In the three cases, we change the distances of the point source with respect to the device to observe the cavity effects induced by the source and the (sub-)THz cavity. Then, we perform a simulation using a 3D model and use a focused THz beam as a source to determine the absorption on the graphene. More details are available in Supp. Fig. S3. The descriptions of the thermoelectrical and electrostatic models are available in Refs. [55] and [44].

Obtaining the detector responsivity and NEP. The external responsivity for our experimental THz spot size is defined by Rext=IPTE/PinR_{\mathrm{ext}} = I_{\mathrm{PTE}}/P_{\mathrm{in}}, where IPTEI_{\mathrm{PTE}} is the peak-to-peak value of the demodulated PTE photocurrent signal measured with the lock-in amplifier and PinP_{\mathrm{in}} is the incoming power measured at the focus position. We calculate the peak-to-peak value of the photocurrent using IPTE=22π/4⋅Ilock−inI_{\mathrm{PTE}} = 2\sqrt{2\pi}/4 \cdot I_{\mathrm{lock-in}}, where Ilock−inI_{\mathrm{lock-in}} is the root mean square value of the demodulated photocurrent signal measured by the lock-in amplifier. The external noise-equivalent power is NEPext=Inoise/Rext\mathrm{NEP}_{\mathrm{ext}} = I_{\mathrm{noise}}/R_{\mathrm{ext}}, where Inoise=4kBTΔf/RI_{\mathrm{noise}} = \sqrt{4k_{\mathrm{B}}T\Delta f/R} is the Johnson noise, kBk_{\mathrm{B}} is the Boltzmann constant, T=300T = 300 K is the temperature, Δf=1\Delta f = 1 Hz is the measurement bandwidth and R=500 ΩR = 500\ \Omega is the channel resistance. In the experiment, the non-diffraction-limited focus area was around 57.8 mm2^2 (see Supp. Fig. S10). The ideal diffraction-limited focus area is given by [39] Adiff=λ02/π≈4.5A_{\mathrm{diff}} = \lambda_0^2/\pi\approx4.5 mm2^2. This gives a ratio Afocus/Adiff≈13A_{\mathrm{focus}}/A_{\mathrm{diff}} \approx13. Since the absorption is already 15–20% in the non-diffraction-limited case, we can expect 100% absorption for a (near-)diffraction-limited spot, giving an ideal responsivity RdiffR_{\mathrm{diff}} (ideal NEPdiff\mathrm{NEP}_{\mathrm{diff}}) that is increased (decreased) by at least a factor five.

Obtaining the absorption from experiments. We first extract the increase in temperature from the photocurrent using IPTE=(S1−S2)ΔT/RI_{\mathrm{PTE}} = (S_1 - S_2)\Delta T/R [39], where S1−S2S_1 - S_2 is the Seebeck coefficient (160 μ\muV K−1^{-1}, known from previous reports [38, 39]), and R=500 ΩR = 500\ \Omega is the resistance of the device. This gives ΔT=1.55\Delta T = 1.55 K for the highest THz power. The following equation describes the relationship between the increase in temperature and the absorption η\eta: ΔT=ηPinτcool2lcoolwCel\Delta T = \frac{\eta P_{\mathrm{in}}\tau_{\mathrm{cool}}}{2l_{\mathrm{cool}}wC_{\mathrm{el}}}, where Cel=1×10−4C_{\mathrm{el}} = 1 \times10^{-4} Jm−2^{-2}K−1^{-1} is the electronic heat capacity, τcool\tau_{\mathrm{cool}} is the cooling time of graphene, lcool=500l_{\mathrm{cool}} = 500 nm is the cooling length in graphene and w=30 μw = 30\ \mum the width of the photoactive area. The cooling length is estimated from the cooling time and the momentum relaxation time [48]. Using these parameters, which are all known, we extract the absorption coefficient.

Thickness measurements. We first measured the thickness of all the materials using a commercial caliper with an accuracy of 10 μm10\,\mu\mathrm{m} as a reference value for comparison. Then, we measured the thickness of all the materials by performing a statistical averaging to improve the accuracy of the thickness determination and to simultaneously mitigate the intrinsic phase drift of our THz system. Concretely, we measure around twenty consecutive scans close to where a local maximum is located (for air and with the material, respectively, see Supp. Fig. S9). To determine the peak position of the curve, we find the maximum value of all the curves and extract Δx\Delta x from each consecutive scan (air and material). Then, the thickness dd is given by Δx/(ns−nair)\Delta x/(n_{\mathrm{s}}-n_{\mathrm{air}}). Finally, we calculate the average thickness and its standard deviation. This procedure was applied to two groups of data without applying any outlier rejection: the first group is the acquired data without any treatment, and the second group is the acquired data treated by smoothing (see Supp. Fig. S9 for more details).

Supplementary information

The Supplementary Information presents details of the fabrication of the device, calculation of interference conditions, optical simulations, telecom-generated photocurrent, comparison with other detectors performances, time-resolved photocurrent measurements, additional measurements aimed at thickness extraction, and details of experimental methods.

Acknowledgments

The ICN2 is funded by the CERCA programme / Generalitat de Catalunya. The ICN2 is supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, funded by MCIU/AEI/10.13039.501100011033. K.-J.T. acknowledges funding from the European Union’s Horizon 2020 research and innovation program under Grant Agreement No. 804349 (ERC StG “CUHL”) and No. 101125457 (ERC CoG “EQUATE”). S.C., K.P.S. and F.H.L.K acknowledge funding by the European Union program under Grant Agreement No. 101113529 (ERC, TER-ACOMM) and PDC2022-133844-I00, funded by MCIN/AEI/10.13039/501100011033 and by the “European Union NextGenerationEU/PRTR”. K.W. and T.T. acknowledge support from the JSPS KAKENHI (Grant Numbers 21H05233 and 23H02052), the CREST (JPMJCR24A5), JST and World Premier International Research Center Initiative (WPI), MEXT, Japan.

Data availability statement

The data that support the findings of this study are available from the corresponding author(s) upon reasonable request.

Competing interests

The authors declare no competing interests.

Author contributions

S.C., F.H.L.K. and K.-J.T conceived the project. R.dlB., E.R. and A.N. conducted the experiments. R.dlB., D.S.R and A.N. performed the TRPC measurements. K.P.S. and S.C. fabricated the device. I.V. and E.L. performed the simulations. S.C. and K.P.S. assisted with the measurements and discussion of the results. K.W. and T.T. synthesized the hBN crystals. R.dlB., E.R., A.N., S.C., F.H.L.K. and K.-J.T. wrote the manuscript with input from all the authors. S.C., F.H.L.K. and K.-J.T. supervised the work and discussed the results. All authors contributed to the scientific discussions and manuscript revisions.

Supplementary Information for “Graphene-enabled coherent (sub-)terahertz wave detection and thin film thickness determination”

Ronny de la Bastida; Enzo Rongione; Karuppasamy Pandian Soundarapandian; Ioannis Vangelidis; Anand Nivedan; David Saleta Reig; Kenji Watanabe; Takashi Taniguchi; Elefterios Lidorikis; Frank H. L. Koppens; Sebastián Castilla; Klaas-Jan Tielrooij

The Supplementary Information contains:

  • S1: Fabrication of the graphene (sub-)THz detector

  • S2: Interference conditions in the internal cavity

  • S3: Optical simulations

  • S4: Photocurrent properties under excitation with 1550 nm light

  • S5: Performance of four (sub-)THz graphene detectors

  • S6: Comparison of external performances of graphene-based free photodetectors

  • S7: Time-resolved photocurrent measurements

  • S8: Phase sensitivity

  • S9: Additional measurements for the thickness determination

  • S10: Experimental methods

Fabrication of the graphene (sub-)THz detector

Device description. The structure of the graphene-based photodetector devices with a (sub-)THz cavity is shown in Supplementary Figure 1 and is based on our previous work on photodetectors exploiting the photothermoelectric effect (PTE) [1, 2]. The step-by-step fabrication process is shown in Suppl. Figure S2, which includes selecting the graphene flake, hBN encapsulation, etching the channel, depositing the source and drain contacts, and depositing the two antenna branches, which simultaneously serve as dual top gates.

THz detector device with integrated cavity

Supplementary Figure 1. THz detector device with integrated cavity. a, Optical microscope image of the device, where the antenna, source and drain contacts, and the hBN-encapsulated graphene stack are identified. b, Schematic side-view of the device. A metallic plate is engineered at the back of a Si-based (sub-)THz photodetector based on single layer graphene (SLG). In this way, the Si interlayer forms a cavity resonant at 89 GHz. An antenna is engineered on top of the SLG to efficiently couple the incoming THz light with the device. c, Schematic top-view of the device.

Image not extracted

Figure S2. Step-by-step fabrication procedure including (a) the hBN-encapsulation of the SLG, (b) the etching of the channel and the deposition of the edge contacts, (c) the top insulation with hBN and (d) the deposition of the top antenna. The optical images (e) to (h) respectively present the corresponding fabrication steps (a) to (d). i, Spatial map of the full width at half maximum (FWHM) of the 2D peak of graphene Γ2D\Gamma_{2D} along with (j) the number of occurrence vs. the FWHM of the 2D peak of graphene.

Interference conditions in the internal cavity

Derivation of the conditions for constructive and destructive interference.

We derive the interference conditions by considering an incident beam and reflected beams at the position of the graphene channel that serves as photoactive material for the detector, as illustrated in Supplementary Figure 3. Making a round trip in the cavity brings to the reflected wave a phase term ϕ=2×2πnSiL/λ0+π\phi= 2 \times2\pi n_{\mathrm{Si}}L/\lambda_0 + \pi, where the last term comes from the fact that nAu>nSin_{\mathrm{Au} } > n_{\mathrm{Si}} [3]. The interference conditions for the field intensity are the following:

Image not extracted

Supplementary Figure 3. Constructive and destructive interferences. Illustration of the interferences conditions in the internal cavity of thickness LL and refractive index nSin_{\mathrm{Si}}.

Δϕ=0+2πM⟹(2M−1)λ0=4nSiL(constructive)Δϕ=π+πM⟹2Mλ0=4nSiL(destructive)(1)\begin{aligned} \Delta\phi&= 0 + 2\pi M \Longrightarrow(2M - 1)\lambda_0 = 4n_{\mathrm{Si}}L \quad\text{(constructive)} \\ \Delta\phi&= \pi+ \pi M \Longrightarrow2M\lambda_0 = 4n_{\mathrm{Si}}L \quad\text{(destructive)} \tag*{(1)} \end{aligned}

The lowest frequency that leads to constructive interference at the graphene plane corresponds to M=1M = 1 and gives a resonance frequency of:

f=c4LnSi(2)f = \frac{c}{4Ln_{\mathrm{Si}}} \tag*{(2)}

Optical simulations

Simulation of the external cavity. We simulate in Supplementary Figure 4 the effect of only the external cavity (formed between the SLG and the silica layer representing the emitter surface). We notice a fringe pattern introduced by the external cavity. The magnitude of the enhancement is typically estimated around ±50\pm50 % compared to the simulation without the external cavity. We simulate in Supplementary Figure 4 the effect of the internal cavity, which induces a larger absorption (up to 40% of absorption, revealing an increase by a factor close to ×10\times10 compared to the reference case without any cavity) in the SLG layer at specific frequencies (78 and 235 GHz). This demonstrates that the internal cavity acts as a (sub-)THz cavity according to the resonance conditions defined in Suppl. Eq. (2). We also observe two times more absorption when simulating the case with both an external and an internal cavity compared to the case with only the internal cavity.

Image not extracted

Supplementary Figure 4. Effect of the internal and external (sub-)THz cavities. a, SLG absorption considering the device without any cavity (left scheme, red curve) and with the external cavity only (right scheme, blue curve). b, SLG absorption considering the effect of the internal cavity (left scheme, red curve) and the effect of both cavities (right scheme, blue curve). In all cases, the introduction of the external cavity corresponds to a source-to-detector distance Lext=36L_{\mathrm{ext}} = 36 cm, and the values correspond to THz light focused with an NA of 1. The insets in (a) and (b) show the periodic oscillations induced by the introduction of the external cavity.

Simulation of external responsivity in graphene. We first simulated and calculated the (sub-)THz absorption in the graphene channel in Supplementary Figure 4, taking into account both the internal cavity (metallic back reflector) and the dipole antenna; only dipole antenna without internal cavity; only internal cavity without dipolar antenna; and without the internal cavity nor dipolar antenna. We observe that the best configuration to increase the absorption is using an internal and external cavity. We next calculate the external responsivity as a function of the frequency for a NA of 0.5 and two different situations : (i) including the internal and external cavity, and (ii) including only internal cavity. We observe that the external cavity enhances the responsivity supporting the previous simulations in Supplementary Figure 4.

External cavity and sub-fringes spacing. We now discuss in detail the effect of the external cavity formed by the SLG layer and the silica layer (representing

Image not extracted

Supplementary Figure 5. Simulation results for absorption and responsivity. a, Calculated (sub-)THz absorption in the graphene channel, taking into account both the internal cavity (metallic back reflector) and the dipole antenna (grey); only dipole antenna without internal cavity (red); only internal cavity without dipolar antenna (pink); and without the internal cavity nor dipolar antenna (green). We multiply each curve by the factor written above it for better visualization. b, Calculated external responsivity as a function of frequency with (grey) and without (blue) the external cavity.

the THz source) as presented in Supplementary Figure 6. We consider two cases: i) the case of a source-detector distance LextL_{\mathrm{ext}} of 36 cm (two mirrors case), and ii) the case of a source-detector distance of 61 cm (four mirrors case). The simulation gives a fringe spacing of Δf1≃400\Delta f_1 \simeq400 MHz in the first case, and about Δf2≃250\Delta f_2 \simeq250 MHz. This trend is also recovered experimentally in Supplementary Figure 7 and supported by performing a Fourier transform of the experimental data as shown in Supplementary Figure 8. We relate this effect to the constructive/destructive interferences of the reflected light back at the emitter plane, with a fringe condition matching Δf=c/2Lext\Delta f = c/2L_{\mathrm{ext}}. It is important to note here that the magnitude effect of the fringes in the spectral response is only around ±50%\pm50\%, so that the main (sub-)THz absorption increase still comes from the internal sub-THz cavity.

Image not extracted

Supplementary Figure 6. Sub-fringes structure in the spectrum induced by external source-detector cavity. We simulate two cases: (a) two parabolic mirrors configuration where the distance between the emitter and the detector is 36 cm. We observe in (b) the SLG absorption, oscillating with a frequency of c2Lext\frac{c}{2L_{\mathrm{ext}}}. For the second case, we simulate a (c) four parabolic mirrors configuration with a distance between the emitter and the detector of 61 cm. We observe in (d) the SLG absorption oscillating with a frequency of c2Lext\frac{c}{2L_{\mathrm{ext}}}.

Image not extracted

Supplementary Figure 7. Interference pattern observed when scanning the detector position. a,b, Photocurrent measured while moving the detector along the travel direction of the light for incident radiation at 89 GHz (a) and 160 GHz (b), together with the Fourier transforms of these interference patterns (c,d). These results show oscillations due to interference with a period of 3.35 mm, on top of an envelope due to focusing, with a length scale of more than 10 mm, as expected for this wavelength and the numerical aperture of 0.5. The Fourier transforms are performed to determine the periodicity of the signals and give main peaks at 1.79 mm and 0.98 mm for 89 and 160 GHz, respectively. This is close to half of the wavelength of the incident light, which is 1.69 mm and 0.94 mm, respectively. The inset in panels (c) and (d) show that the deviation between the fringe period obtained using 2 and 13 cycles of the interference pattern in panel (a) is around 10%, while the deviation between using 2 and 15 cycles of the interference pattern in panel (b) is around 1%. This is likely the result of frequency and (associated) phase drift. The fact that we observe oscillations for both frequencies shows that the occurrence of interference is not limited to the resonance frequency of the internal cavity.

Image not extracted

Supplementary Figure 8. Experimental signatures of the external cavity. a,b Photocurrent signal for source-detector distances LextL_{\mathrm{ext}} of 36 cm (a) and 61 cm (b), showing a spectral substructure. c,d Fourier transforms of the photocurrent signals for LextL_{\mathrm{ext}} of 36 cm (c) and 61 cm (d), showing a periodicity of 0.5 GHz and 0.23 GHz, respectively. The expected periodicity due to the external cavity is given by c/2Lextc/2L_{\mathrm{ext}}, which gives 0.4 GHz and 0.25 GHz, respectively.

Response of the device vs. position along the THz propagation path.

We present the simulated response of the device vs position xx for two different frequencies, 89 GHz (Suppl. Figure S9) and 160 GHz (Suppl. Figure S9). We observe that the oscillation period Δx\Delta x (1.69 mm for 89 GHz and 0.94 mm for 160 GHz) matches closely the one obtained experimentally. The effect of the internal and external cavity is then demonstrated at 160 GHz in Suppl. Figure S9 where we see a large increase of the SLG absorption compared to the absorption of the SLG without any cavity. Finally, we report in Suppl. Figure S9 the effect of inserting a 500 μ\mum Si wafer between the source and the detector at 89 GHz, shifting the oscillation by Δx\Delta x corresponding to d/(ns−1)d/(n_{\mathrm{s}} - 1).

Image not extracted

Figure S9. Simulated detector response as a function of its position xx. We simulate the absorption of the SLG by moving the position of the detector along the focal plane. First, we simulate for two different frequencies: (a) 89 GHz and (b) 160 GHz. Second, we simulate (c) the presence of the interference pattern with a Si wafer of 500 µm between the THz emitter and the coherent graphene receiver (blue curve), without the Si wafer (red line), and the absorption of the SLG without any cavity (black dashed curve) at 89 GHz. Finally, we observe the contribution of the internal and external cavity by simulating (d) SLG with the internal and external cavity (green line) and the SLG without any cavity (black dashed line) at 160 GHz.

Photocurrent properties under excitation with 1550 nm light

Photocurrent vs. position for 1550 nm light. We report in Suppl. Fig. 10 the photocurrent as a function of position along the propagation direction xx for light with a near-infrared (NIR), or “telecom”, wavelength of 1550 nm. We observe, contrary to the (sub-)THz-generated photocurrent case, no photocurrent oscillations. For this wavelength, λ0/2≃775\lambda_0/2 \simeq775 nm, which is too small to be observed with our minimal step size of 1.25 μ\mum.

Profile of the telecom photocurrent vs focal position

Supplementary Figure 10. Profile of the telecom photocurrent vs focal position. Photocurrent generated from telecom pump as a function of the position across the propagation direction xx.

Mode filling of the cavity with 1550 nm light. To determine the spectral response of the cavity under telecom pumping, we assume that the sub-THz cavity of thickness LL possesses a refractive index of nNIR≃3.5n_{\mathrm{NIR}} \simeq3.5 [4] at NIR/telecom frequencies, different compared to THz frequencies nTHz≃3.4n_{\mathrm{THz}} \simeq3.4 [4], and that the cavity resonance follows the condition of L=(2M−1)λ0/4nL = (2M - 1)\lambda_0/4n. This condition is valid in both telecom and THz ranges, where nn is nNIRn_{\mathrm{NIR}} or nTHzn_{\mathrm{THz}}, respectively. The number of modes in the cavity MM is expressed by the following equation:

M=⌊2nLcf−12⌋(3)M = \left\lfloor\frac{2nL}{c}f - \frac{1}{2} \right\rfloor \tag*{(3)}

where the operator ⌊M⌋\lfloor M \rfloor indicates rounding to the nearest integer that is smaller than or equal to MM. When the cavity accepts/rejects a new mode, the increment matches a constructive interference. We calculate the response of the cavity under 1550 nm pumping and compare it to the experimental photocurrent in Supplementary Figure 11. We observe a very good agreement between our experimental results with the mode filling of a sub-THz cavity.

Determination of the frequency response of the cavity under 1550 nm pumping

Supplementary Figure 11. Determination of the frequency response of the cavity under 1550 nm pumping. Estimation of the number of telecom modes filling the cavity compared to the experimental measurements of the photocurrent.

Performance of four (sub-)THz graphene detectors

Photocurrent response of four (sub-)THz detector-interferometer devices

Supplementary Figure 12. Photocurrent response of four (sub-)THz detector-interferometer devices. We measure the photocurrent IPTEI_{\mathrm{PTE}} vs. frequency ff for the four different devices. We vary the thickness of the Si substrates to fix the resonance frequency of the cavity to (a) ∼90\sim90 GHz, (b), (c) and (d) ∼40\sim40 GHz corresponding to a thickness of the Si substrate of (a) 280 μ\mum, (b), (c) and (d) 525 μ\mum. We optimized the responsivity by varying the length ll and the width ww of the graphene channel, where Device 1 has w=30w = 30 μ\mum and l=2l = 2 μ\mum, Devices 2 and 3 have w=1w = 1 μ\mum and l=1l = 1 μ\mum, and Device 4 has w=3w = 3 μ\mum and l=1l = 1 μ\mum.

Comparison of external performances of graphene-based free photodetectors

We present in Suppl. Table 1 a comparison of the performance of different graphene-based THz detectors. In order to compare the performance, we calculate the external responsivity of the detectors using the information provided in each reference. Since the responsivity is calculated by different approaches across the literature [5], such as the geometry of active area of the antenna, or diffraction-limited spot size, we decide to use the external responsivity as the factor of merit of those detectors, which allows for easier comparison of the performances throughout different setups and detector designs.

Device designFrequencyResponsivityNEPReference
Square-spiral antenna without cavity80–120, 140, 300 GHz1.4 mA/W1.4\ \mathrm{mA/W}{sup}** (2.8 mV/W2.8\ \mathrm{mV/W}{sup}*)35 mW Hz−1/235\ \mathrm{mW\ Hz^{-1/2}}Guo et al. [6]
Log-periodic antenna120 GHz0.84 mA/W0.84\ \mathrm{mA/W}{sup}** (840 mV/W840\ \mathrm{mV/W}{sup}*)33.3 nW Hz−1/233.3\ \mathrm{nW\ Hz^{-1/2}}{sup}*Liu et al. [7]
Dipolar antenna without cavity1.8–4.25 THz0.42 mA/W0.42\ \mathrm{mA/W}{sup}* (1.76 mV/W1.76\ \mathrm{mV/W}{sup}**)4.8 nW Hz−1/24.8\ \mathrm{nW\ Hz^{-1/2}}{sup}*Castilla et al. [1]
Bow-tie antenna with cavity2.86 THz≈0.1 mA/W\approx0.1\ \mathrm{mA/W}{sup}** (≈2 V/W\approx2\ \mathrm{V/W}{sup}*)5.4 nW Hz−1/25.4\ \mathrm{nW\ Hz^{-1/2}}{sup}*Viti et al. [8]
Integrated (sub-)THz cavity and dipolar antenna (Device 1)89 GHz73 mA/W73\ \mathrm{mA/W} (36 V/W36\ \mathrm{V/W})79 pW Hz−1/279\ \mathrm{pW\ Hz^{-1/2}}This work
Integrated (sub-)THz cavity and bow-tie antenna (Device 4)53 GHz172 mA/W172\ \mathrm{mA/W} (138 V/W138\ \mathrm{V/W})26 pW Hz−1/226\ \mathrm{pW\ Hz^{-1/2}}This work

Table 1. Comparison of the external performance of graphene-based, bias-free photodetectors. *Maximum external responsivities calculated considering the experimental focus area using the normalization factor provided in the referenced papers. **These values were converted using the values reported in the referenced papers, such that they correspond to values without normalization.

Time-resolved photocurrent measurements

Reflectance and photocurrent map. We present in Supplementary Figure 14 the reflectance and photocurrent maps of the device in the region of the antenna/graphene region obtained using only the pump beam. We observe the geometry of the device in Supplementary Figure 14 and focus on the region of interest. In Supplementary Figure 14, we show the photocurrent measured by moving the device with the xyzxyz stage. We observe three photocurrent spots. By comparing their positions to the reflectance map, we realize that two of them originate from the photoactive region, while the last one is located outside the graphene channel. This is evidence of photocurrent that is induced by incident light that is absorbed in graphene via a reflection of the metallic back mirror.

Reflectance and photocurrent maps

Supplementary Figure 14. Time-resolved photocurrent map. a, Reflection map and b, photocurrent map in the region of the antenna/graphene channel. The dashed black circle indicates the spot where the photocurrent dynamics were measured.

Determination of the cooling time from the TRPC measurements. In order to determine the cooling time of the hot-electrons in the graphene THz detector, we perform time-resolved photocurrent measurements with an incident wavelength of 1030 nm. For details on the technique, see Methods and Ref. [9]. To measure the cooling time, we use a time-resolved photocurrent technique explained in Methods section. We used a power of around 600 μW600\,\mu\mathrm{W} for both lasers and record the PTE photocurrent as shown in Suppl. Fig. 15. We observe a pronounced main dip at zero time delay, and secondary periodic dips that are likely related to reflections inside the (sub-)THz cavity. To extract the cooling time from the time-resolved photocurrent, we describe the photocurrent using a sum of exponential decay functions of the form IPTE∝(Te−Tl)exp⁡(−τdelayτcool)I_{\mathrm{PTE}} \propto(T_{\mathrm{e}}-T_{\mathrm{l}})\exp\left(-\frac{\tau_{\mathrm{delay}}}{\tau_{\mathrm{cool}}}\right) [9, 10], where TeT_{\mathrm{e}}, TlT_{\mathrm{l}}, τdelay\tau_{\mathrm{delay}}, τcool\tau_{\mathrm{cool}} are the electronic temperature, lattice temperature, the delay time, and the cooling time, respectively. Each dip has two exponentially decaying functions – to positive and to negative time delays. We obtain a cooling time of 3.4 ps for the main dip around time zero.

Time-resolved photocurrent measurements

Figure 15. PTE photocurrent measured using time-resolved photocurrent technique (green points) and the sum of exponential decay function (solid line). We observe a main dip at zero time delay followed by two secondary periodic dips related to reflections inside the (sub-)THz cavity.

Phase sensitivity

Determination of phase sensitivity The photocurrent could be described as typical Airy function of a Fabry-Perot cavity like IPTE=I011+Fsin⁡2φ+IoffsetI_{\mathrm{PTE}}=I_0\frac{1}{1+F\sin^2\varphi}+I_{\mathrm{offset}}, where I0I_0 is the maximum photocurrent, FF is the coefficient of the finesse, φ=2πx/λ0\varphi=2\pi x/\lambda_0 is the phase accumulation and IoffsetI_{\mathrm{offset}} is the offset of the photocurrent due to the envelope of the THz Gaussian beam. We observed good agreement by fitting the experimental data and the simulation of the photocurrent oscillation in Supplementary Figure 16,Supplementary Figure 16, extracting a finesse coefficient of 0.05 using the experimental data and 2 using the simulation data.

Airy function of oscillation photocurrent pattern

Supplementary Figure 16. Airy function of oscillation photocurrent pattern. We describe the photocurrent oscillation pattern (red points) using an Airy function (solid lines) for the (a) experimental measurements and (b) simulation.

To obtain the spatial sensitivity, we applied a numerical derivative to the experimental and fitting data in Supplementary Figure 16, calculating a maximum phase sensitivity of 375 nA/mm as shown in Supplementary Figure 17. We transform spatial to phase sensitivity using ∂IPTE∂φ=∂IPTE∂x⋅∂x∂φ\frac{\partial I_{\mathrm{PTE}}}{\partial\varphi}=\frac{\partial I_{\mathrm{PTE}}}{\partial x}\cdot\frac{\partial x}{\partial\varphi} where ∂x∂φ=λ02π\frac{\partial x}{\partial\varphi}=\frac{\lambda_0}{2\pi}.

Spatial and phase sensitivity plot

Supplementary Figure 17. Spatial and phase sensitivity. We extract spatial sensitivity (∂IPTE/∂x)(\partial I_{\mathrm{PTE}}/\partial x) and phase sensitivity (∂IPTE/∂φ)(\partial I_{\mathrm{PTE}}/\partial\varphi) of our sub-THz interferometer by performing the numerical derivative in Supplementary Figure 16 for experimental data (points) and fitted Airy function (solid line).

Determination of noise photocurrent During the extraction of the thicknesses, potential uncertainties entering into error bars could intervene. The first main effect is the phase drift of the THz system, that relies on two photomixed DFB

lines to produce a THz beating note. A frequency drift of each DFB due to thermal fluctuations would here result in a source of error. We next measure at 89 GHz for one hour, as shown in Supplementary Figure 18 and calculate the noise photocurrent related to the phase drift of our THz source by extracting the standard deviation of the photocurrent along this period of time.

Photocurrent variation over time

Supplementary Figure 18. Evaluation of the graphene detector noise. Photocurrent variation as a function of time tt at 89 GHz using our graphene-based (sub-)THz detector-interferometer, measured during a period that is equal to the time it takes to perform a thickness measurement. The noise of the signal is 3.6 nA, extracted as the standard deviation from the root mean square value of the photocurrent.

Determination of phase drift. We determine the phase of the THz wave by measuring a small frequency window with our (sub-)THz interferometer with an interval period of one minute as shown in Supplementary Figure 19. We then extracted the resonance frequency of each scan by looking at the maximum photocurrent value. We observe in Supplementary Figure 19 a frequency drift, most likely due to the variation of temperature of the DFB lasers. This drift can lead to a frequency change up to 100 MHz for a measurement of one hour. To extract the frequency fluctuations of our THz source, we subtract the general tendency of the frequency drift by fitting with a polynomial function. The remaining fluctuations have a standard deviation of ∼5\sim5 MHz. To extract the relation between the frequency drift and the phase drift, we use that phase and frequency of the external cavity are related via φ=πLf/c\varphi= \pi L f / c, where LL is the length of the cavity between the THz source and the detector (36 cm), and ff the frequency of the THz source. We thus obtain that the phase noise is δφ=πLδf/c\delta\varphi= \pi L \delta f / c, where δf\delta f is the frequency fluctuation. This gives a phase noise of 0.018 rad, which is very similar to experimentally obtained phase accuracy.

Temporal evolution of the frequency response and frequency and phase drift of the THz source

Supplementary Figure 19. Determination of frequency and phase drift of the THz source. (a) Temporal evolution of the frequency response of our (sub-)THz detector. (b) Frequency drift extracted by locking the frequency at the maximum IPTE (red points) in (a) and the phase drift tendency (black solid line) by fitting a polynomial fit. The inset shows the frequency fluctuation on top of the drift, obtained by subtracting the long-term frequency drift. The standard deviation of these fluctuations is around 5 MHz.

Additional measurements for the thickness determination

Thickness extraction method. To extract the thickness of different materials, we choose four different materials with different refractive indices (nsn_s): silicon, paper, scotch tape (polypropylene, PP) and Kapton tape (polyimide). We first measure the photocurrent IPTEI_{\mathrm{PTE}} along the THz propagation axis xx to observe around three oscillations without the material in front of the detector (air case) and with the material in front of it. Then, we estimate the range of the shift Δx\Delta x (with respect to the xyzxyz stage position) to know the limits where we need to move the stage to observe two peaks (with and without the material). Because our detector is very sensitive to phase changes, the intrinsic phase drift of our THz emitter creates a mismatch in the measurement. To solve this problem, we decrease the scanning window using our previous estimation of how long we need to move the stage to observe the two peaks, leading to a faster measurement in terms of time, thus minimizing the effect of potential phase drift. We measure the photocurrent without the material in front of the detector and then with the material in front of the detector. To increase the accuracy of our measurements, we perform twenty cycles to enhance our statistical analysis as shown in Supplementary Figure 20.

Cycles of measurements for the thickness estimation

Supplementary Figure 20. Cycles of measurements for the thickness estimation. Complete measurements for photocurrent IPTEI_{\mathrm{PTE}} vs position xx of the detector along the THz propagation direction, without (red solid lines) and with the sample (blue solid lines) in front of the detector, for (a) Si, (b) Paper, (c) Kapton, and (d) Polypropylene (PP).

To calculate the thickness, we apply two different methods to the same dataset: i) the first method calculates the shift Δx\Delta x (as discussed in the main text) by searching the maximum value of the consecutive scans and calculating the thickness dd of each cycle (with and without the material) via d=Δx/(ns−1)d = \Delta x/(n_s - 1). The second method ii) first performs a smoothing of each measurement in the dataset with a window of eleven points, and then we estimate the thickness in the same way as discussed for the first method. For both methods, the twenty estimated thicknesses are averaged and the standard deviation (error bars) is calculated.

We present in Supplementary Figure 21 the extracted thickness and standard deviation from the two methods discussed above. The blue points correspond to the raw data method (method (i)) and the green points correspond to the smoothed data method (method (ii)). The method presented in the main text is the smoothed data method.

Comparison of thickness estimation using two different methods

Supplementary Figure 21. Comparison of thickness estimation using two different methods. a, Extracted thickness dd vs. expected thickness d∗d^{*} using the raw data (open blue symbols) and smoothed data (solid green symbols). b, Obtained thickness accuracy δd\delta d as a function of refractive index for the different materials, using the raw data (open blue symbols) and smoothed data (solid green symbols).

Experimental methods

We show in Supplementary Figure 22 and Supplementary Figure 23 the schematic of the THz and time-resolved photocurrent setups (see Methods). The THz power of the emitter as a function of the frequency is measured at the sample position with a calibrated pyroelectric THz detector (Supplementary Figure 24) and the power of the THz beam as a function of the emitter bias is shown in Supplementary Figure 24. We show our THz beam by measuring the photocurrent along the yzyz plane in Supplementary Figure 25. We also determine the size of our beam by measuring the Gaussian profile of our photocurrent along the axes yy and zz, as shown in Supplementary Figure 25.

Terahertz setup

Supplementary Figure 22. Terahertz setup. Continuous wave (CW) THz radiation is emitted by pumping an InGaAs emitter with a photomixed telecom beam, while being biased by a AC voltage, serving as a frequency reference for lock-in measurement. The CW THz beam is focused using two parabolic mirrors, and the detector is placed on an xyzxyz motorized stage to optimize its position. Finally, the photocurrent is measured using a lock-in technique demodulated at the frequency of the AC bias voltage applied to the THz emitter.

Time-resolved photocurrent setup

Supplementary Figure 23. Time-resolved photocurrent setup. The time-resolved photocurrent (TRPC) setup uses a femtosecond laser with a 76 MHz repetition rate and a wavelength of 1030 nm, as explained in the Methods. We divide the beam into two paths using a beam splitter, one of the paths goes directly to an objective and the second through a 325 mm delay line to reach the objective, which focuses both beams on the sample.

Evolution of the THz power as a function of the frequency

(a) Evolution of the THz power as a function of the frequency.

Measured THz power at 89 GHz as a function of the emitter bias

(b) Measured THz power at 89 GHz as a function of the emitter bias.

Supplementary Figure 24. Calibration of the THz source power. The THz power has been measured at the THz focal point (device location) with a pyroelectric sensor (Ophir RM9-THz). A polystyrene foam has been placed in the collimated beam path to remove any residual telecom pump.

Determination of the experimental focus area

Supplementary Figure 25. Supplementary Fig. 25 Determination of the experimental focus area. a, Photocurrent profile when scanning the detector position in the plane perpendicular to the travel direction of light. This is taken at 80 GHz at the best focal distance after the second parabolic mirror, and gives the experimental focus spot size. b, Determination of the focus spot size by describing the photocurrent extracted along the vertical (yy) and horizontal (zz) lines (purple and green data points, respectively) with Gaussian functions (solid lines). We obtain a beam radius w0,y=4.58w_{0,y} = 4.58 mm and w0,z=4.01w_{0,z} = 4.01 mm, corresponding to a full-width at half-maximum of FWHM=2ln⁡2 w0\mathrm{FWHM} = \sqrt{2\ln2}\,w_0. We calculate the focus area as Afocus=π(w0,zw0,y)A_{\mathrm{focus}} = \pi(w_{0,z}w_{0,y}) giving Afocus=57.8A_{\mathrm{focus}} = 57.8 mm2^2.

Supplementary References

References

  1. [1]Taimre, T. et al. Laser feedback interferometry: a tutorial on the self-mixing effect for coherent sensing. Advances in Optics and Photonics 7, 570 (2015).
  2. [2]Rakić, A. D. et al. Sensing and imaging using laser feedback interferometry with quantum cascade lasers. Applied Physics Reviews 6, 021320 (2019).DOI
  3. [3]Tonouchi, M. Cutting-edge terahertz technology. Nature Photonics 1, 97–105 (2007).DOI
  4. [4]Samizadeh Nikoo, M. & Matioli, E. Electronic metadevices for terahertz applications. Nature 614, 451–455 (2023).DOI
  5. [5]Rowan-Robinson, M. Probing the cold universe. Science 325, 546–547 (2009).
  6. [6]Young, E. T. et al. Early science with sofia, the stratospheric observatory for infrared astronomy. The Astrophysical Journal Letters 749, L17 (2012).DOI
  7. [7]Lara-Avila, S. et al. Towards quantum-limited coherent detection of terahertz waves in charge-neutral graphene. Nature Astronomy 3, 983–988 (2019).
  8. [8]Appleby, R. & Anderton, R. N. Millimeter-Wave and Submillimeter-Wave Imaging for Security and Surveillance. Proceedings of the IEEE 95, 1683–1690 (2007).DOI
  9. [9]Valzania, L. et al. THz coherent lensless imaging. Applied Optics 58, G256–G275 (2019).DOI
  10. [10]Li, X., Li, J., Li, Y., Ozcan, A. & Jarrahi, M. High-throughput terahertz imaging: progress and challenges. Light: Science & Applications 12, 233 (2023).DOI
  11. [11]Pfeiffer, T. et al. Terahertz thickness determination with interferometric vibration correction for industrial applications. Optics Express 26, 12558–12568 (2018).DOI
  12. [12]Park, J., Kim, J.-A., Ahn, H., Bae, J. & Jin, J. A Review of Thickness Measurements of Thick Transparent Layers Using Optical Interferometry. International Journal of Precision Engineering and Manufacturing 20, 463–477 (2019).DOI
  13. [13]Ellrich, F. et al. Terahertz quality inspection for automotive and aviation industries. Journal of Infrared, Millimeter, and Terahertz Waves 41, 470–489 (2020).DOI
  14. [14]Liebermeister, L. et al. Terahertz Multilayer Thickness Measurements: Comparison of Optoelectronic Time and Frequency Domain Systems. Journal of Infrared, Millimeter, and Terahertz Waves 42, 1153–1167 (2021).DOI
  15. [15]Nagatsuma, T., Ducournau, G. & Renaud, C. C. Advances in terahertz communications accelerated by photonics. Nature Photonics 10, 371–379 (2016).DOI
  16. [16]Marconi, S. et al. Photo thermal effect graphene detector featuring 105 Gbit.s−1 NRZ and 120 Gbit.s−1 PAM4 direct detection. Nature Communications 12, 806 (2021).
  17. [17]Kakande, J. et al. Multilevel quantization of optical phase in a novel coherent parametric mixer architecture. Nature Photonics 5, 748–752 (2011).DOI
  18. [18]Samsonov, E. et al. Coherent detection schemes for subcarrier wave continuous variable quantum key distribution. Journal of the Optical Society of America B 38, 2215–2222 (2021).DOI
  19. [19]Wang, Y. et al. Ultrahigh-speed graphene-based optical coherent receiver. Nature Communications 12, 5076 (2021).DOI
  20. [20]Seeds, A. J. et al. Coherent terahertz photonics. Optics Express 21, 22988 (2013).DOI
  21. [21]Harter, T. et al. Silicon–plasmonic integrated circuits for terahertz signal generation and coherent detection. Nature Photonics 12, 625–633 (2018).
  22. [22]Thomson, M. D. et al. Coherent terahertz detection via ultrafast dynamics of hot Dirac fermions in graphene. ACS Nano 18, 4765–4774 (2024).DOI
  23. [23]Valdmanis, J. A., Mourou, G. & Gabel, C. W. Picosecond electro-optic sampling system. Applied Physics Letters 41, 211–212 (1982).DOI
  24. [24]Wu, Q. & Zhang, X.-C. Ultrafast electro-optic field sensors. Applied Physics Letters 68, 1604–1606 (1996).
  25. [25]Jiang, Z. & Zhang, X.-C. Electro-optic measurement of THz field pulses with a chirped optical beam. Applied Physics Letters 72, 1945–1947 (1998).DOI
  26. [26]Liebermeister, L. et al. Optoelectronic frequency-modulated continuous-wave terahertz spectroscopy with 4 THz bandwidth. Nature Communications 12, 1071 (2021).DOI
  27. [27]Ben-Atar, K., Deninger, A., Engelberg, J. & Levy, U. Amplitude and Phase Imaging of CW-THz Waves Using a Photomixing System with Coherent Detection. Journal of Infrared, Millimeter, and Terahertz Waves 46, 16 (2025).
  28. [28]Rakić, A. D. et al. Swept-frequency feedback interferometry using terahertz frequency QCLs: a method for imaging and materials analysis. Optics Express 21, 22194–22205 (2013).
  29. [29]Nguyen, T., Valera, J. & Moore, A. Optical thickness measurement with multi-wavelength THz interferometry. Optics and Lasers in Engineering 61, 19–22 (2014).DOI
  30. [30]Koppens, F. H. L. et al. Photodetectors based on graphene, other two-dimensional materials and hybrid systems. Nature Nanotechnology 9, 780–793 (2014).DOI
  31. [31]Chen, Z. et al. Research advances and perspectives on terahertz detection based on 2D materials. Advanced Physics Research 4, 2400094 (2025).DOI
  32. [32]Vicarelli, L. et al. Graphene field-effect transistors as room-temperature terahertz detectors. Nature Materials 11, 865–871 (2012).DOI
  33. [33]Muraviev, A. V. et al. Plasmonic and bolometric terahertz detection by graphene field-effect transistor. Applied Physics Letters 103, 181114 (2013).DOI
  34. [34]Bandurin, D. A. et al. Resonant terahertz detection using graphene plasmons. Nature Communications 9, 5392 (2018).
  35. [35]Viti, L., Purdie, D. G., Lombardo, A., Ferrari, A. C. & Vitiello, M. S. HBN-Encapsulated, Graphene-based, Room-temperature Terahertz Receivers, with High Speed and Low Noise. Nano Letters 20, 3169–3177 (2020).DOI
  36. [36]Caridad, J. M. et al. Room-temperature plasmon-assisted resonant THz detection in single-layer graphene transistors. Nano Letters 24, 935–942 (2024).DOI
  37. [37]Yao, Y. et al. Configurable microcavity-enhanced graphene photothermoelectric terahertz detectors. Photonics Research 12, 2300 (2024).
  38. [38]Soundarapandian, K. P. et al. High-speed graphene-based sub-terahertz receivers enabling wireless communications for 6G and beyond. Nature Communications 17, 2627 (2026).
  39. [39]Castilla, S. et al. Fast and Sensitive Terahertz Detection Using an Antenna-Integrated Graphene pn Junction. Nano Letters 19, 2765–2773 (2019).DOI
  40. [40]Muench, J. E. et al. Waveguide-Integrated, Plasmonic Enhanced Graphene Photodetectors. Nano Letters 19, 7632–7644 (2019).DOI
  41. [41]Schuler, S. et al. High-responsivity graphene photodetectors integrated on silicon microring resonators. Nature Communications 12, 3733 (2021).DOI
  42. [42]Asgari, M. et al. Chip-Scalable, Room-Temperature, Zero-Bias, Graphene-Based Terahertz Detectors with Nanosecond Response Time. ACS Nano 15, 17966–17976 (2021).DOI
  43. [43]Koepfli, S. M. et al. Controlling photothermoelectric directional photocurrents in graphene with over 400 GHz bandwidth. Nature Communications 15, 7351 (2024).DOI
  44. [44]Castilla, S. et al. Electrical spectroscopy of polaritonic nanoresonators. Nature Communications 15, 8635 (2024).DOI
  45. [45]Ludwig, F. et al. Terahertz Detection with Graphene FETs: Photothermoelectric and Resistive Self-Mixing Contributions to the Detector Response. ACS Applied Electronic Materials 6, 2197–2212 (2024).DOI
  46. [46]Gabor, N. M. et al. Hot carrier–assisted intrinsic photoresponse in graphene. Science 334, 648–652 (2011).DOI
  47. [47]Franta, D. et al. Temperature-dependent dispersion model of float zone crystalline silicon. Applied Surface Science 421, 405–419 (2017).DOI
  48. [48]Massicotte, M., Soavi, G., Principi, A. & Tielrooij, K.-J. Hot carriers in graphene – fundamentals and applications. Nanoscale 13, 8376–8411 (2021).DOI
  49. [49]Tielrooij, K.-J. et al. Out-of-plane heat transfer in van der Waals stacks through electron–hyperbolic phonon coupling. Nature Nanotechnology 13, 41–46 (2018).DOI
  50. [50]Roggenbuck, A. et al. Coherent broadband continuous-wave terahertz spectroscopy on solid-state samples. New Journal of Physics 12, 043017 (2010).DOI
  51. [51]Zhai, M., Locquet, A. & Citrin, D. S. Terahertz imaging for paper handling of legacy documents. Sensors (Basel) 21, 6756 (2021).DOI
  52. [52]Cunningham, P. D. et al. Broadband terahertz characterization of the refractive index and absorption of some important polymeric and organic electro-optic materials. Journal of Applied Physics 109, 043505–043505–5 (2011).DOI
  53. [53]Sahin, S., Nahar, N. K. & Sertel, K. Dielectric Properties of Low-Loss Polymers for mmW and THz Applications. Journal of Infrared, Millimeter, and Terahertz Waves 40, 557–573 (2019).DOI
  54. [54]Deninger, A. J., Roggenbuck, A., Schindler, S. & Preu, S. 2.75 THz tuning with a triple-DFB laser system at 1550 nm and InGaAs photomixers. Journal of Infrared, Millimeter, and Terahertz Waves 36, 269–277 (2015).DOI
  55. [55]Vangelidis, I. et al. Unbiased Plasmonic-Assisted Integrated Graphene Photodetectors. ACS Photonics 9, 1992–2007 (2022).DOI

Paper details

vlnc:W_cvdxmfak
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents