betaFeedback

WorksPhysics and Astronomy

Quartet state of the neutral nitrogen-vacancy center in diamond and optimized spin readout under near-infrared two-photon excitation

Abstract

Photoionization of the excited nitrogen-vacancy center (NV-) in diamond leaves the neutral defect in a metastable quartet state of unknown energy. Using two-photon optically detected magnetic resonance with a tunable femtosecond laser, we resolve its onset in the spin contrast at 1.23 +/- 0.02 eV and, with the ground-state threshold from the same setup, place the quartet 0.54 +/- 0.04 eV above the neutral ground state. The threshold sets the optimum excitation for spin readout at 1060-1075 nm, in the near-infrared tissue window, with 26-37% higher shot-noise-limited sensitivity than at 1030-1040 nm.

Introduction

The negatively charged nitrogen–vacancy center (NV−^{-}) in diamond, a substitutional nitrogen next to a vacancy Figure 1(a), is the leading solid-state quantum sensor [1, 2, 3, 4]. Two-photon excitation in the near infrared adds intrinsic optical sectioning and deeper penetration into scattering tissue; it has been used to image fluorescent nanodiamonds in cells [5, 6, 7] and, recently, to read out the spin by optically detected magnetic resonance (ODMR) [8]. Under intense femtosecond excitation, however, the defect is ionized [9], and the spin contrast depends on which ionization channels the laser opens.

Figure 1. (a) NV center: nitrogen (N) next to a vacancy (dot), C3C_3 axis along ⟨111⟩\langle111\rangle, and spin density of NV−^- on the three carbon dangling bonds (red); adapted from Ref. [19]. (b) One-electron a1a_1 and ee levels in the gap and their occupation; A removes an ee electron from 3A2^3A_2 (→2E\to^2E), Q the minority-spin ee electron from 3E^3E, leaving three parallel spins (→4A2\to^4A_2). (c) Total-energy diagram of NV−^- and NV0+eCB−^0+e_{\mathrm{CB}}^- with the excitation (2ℏω2\hbar\omega, dotted gray), ionization (A, I, Q) and recharge (R, Rq_q) channels; orange, spin-related; blue, spin-blind; dotted, two-photon steps; gray, channels through the singlets (ionization of 1A1^1A_1 and 1E^1E, recharge into 1E^1E), which leave no separate signature (see text). The singlets are drawn at an illustrative singlet–triplet gap of 0.36 eV. (d) Top: measured photoluminescence SS (300 mW, circles) and the NV−^- two-photon absorption cross section of Ref. [18] (triangles), each normalized at its maximum. Bottom: the channels of (c) in the order of the cycle, each drawn on the open side of its threshold (vertical tick) for the number of photons it needs; NV−^- excitation, I and R are open over the whole range (arrows, with the threshold beyond it); the singlet channels, whose thresholds depend on the singlet–triplet gap, are omitted; the shaded part of the Q bar marks the onset broadened by the inhomogeneous width and the laser bandwidth. Dashed line, 1E→1A1^1E \to^1A_1 resonance (1042 nm); green band, measured optimum.

The central channel is photoionization of the spin-polarizing excited state 3E^{3}E. Ejecting an e−^{-} electron from the a11e3a_{1}^{1}e^{3} configuration of 3E^{3}E leaves NV0^{0} in an a11e2a_{1}^{1}e^{2}, whose lowest state is the quartet 4A2^{4}A_{2}, not the a12e1a_{1}^{2}e^{1} ground state 2E^{2}E [10] Figure 1(b). The existence of the 4A2^{4}A_{2} quartet state has been established by electron paramagnetic resonance (EPR) measurements [11, 12], but its energy relative to the 2E^{2}E ground state remains uncertain: calculations place it 0.48–0.68 eV above 2E^{2}E [13, 14], an estimate from room-temperature photoionization thresholds gives ≈ 0.4 eV [13], and a cavity experiment at two fixed infrared wavelengths bounds it by ≤ 0.58 eV [15]. One-photon ionization of 3E^{3}E has otherwise been used at a single wavelength, 1064 nm [16].

In this Letter we resolve the onset of the 3E→^{3}E \rightarrow NV0^{0}(4A2^{4}A_{2}) channel spectrally. With one tunable source we measure its threshold EqE_{\mathrm{q}} and the ionization potential of the ground state, IP(3A2^{3}A_{2}), on the same sample at the same temperature, which gives the quartet energy without assumptions about temperature shifts, and locate the excitation wavelength that maximizes the sensitivity of two-photon ODMR of NV−^{-}.

Channels and thresholds. Figure 1(c) shows the channels in a total-energy diagram. Two photons excite NV−^{-} from 3A2^{3}A_{2} to 3E^{3}E (zero-phonon line EZPL=1.945E_{\mathrm{ZPL}} = 1.945 eV).

Two photons ionize the ground state into NV0^{0}(2E^{2}E) above IP(3A2^{3}A_{2}) (channel A); this route is spin-blind. A third photon ionizes the freshly excited 3E^{3}E, either into 4A2^{4}A_{2} (Q) or into 2E^{2}E (I); both act on a spin-polarized state and remove spin contrast. Excited NV−^{-} is recharged by one further photon (R), the quartet by two (Rq_{\mathrm{q}}). The thresholds are linked by [10]

Eq=IP(3A2)−EZPL+[E(4A2)−E(2E)].(1)E_{\mathrm{q}} = \mathrm{IP}(^{3}A_{2}) - E_{\mathrm{ZPL}} + [E(^{4}A_{2}) - E(^{2}E)] . \tag*{(1)}

By Eq. (1), an onset near 1.2 eV requires a final state about 0.5 eV above 2E^{2}E. Group theory and Hund’s rule leave a single candidate: the 4A2^{4}A_{2} quartet, the state identified by its EPR signal [11, 12]. Channel I is allowed by direct ionization into the a11e2a_{1}^{1}e^{2} admixture (8–28%) of the correlated 2E^{2}E ground state [13]; an Auger process [17] may contribute.

Figure 1(d) places the thresholds on the laser axis together with the measured excitation spectrum. The optimum is expected between the last spin-destroying onset (Q, Rq_{\mathrm{q}}) and the fall of the two-photon absorption of NV−^{-} [18].

Experiment. The sample is a single-crystal ⟨100⟩\langle100\rangle diamond grown by chemical vapor deposition, from Diamond Elements Pvt. Ltd. [20] ([N] = 10 ppm, 0.3 mm thick), with an NV density estimated at ≈ 0.1 ppm (NV/N ≈ 1%); it is measured in a single-objective epi-configuration. The beam of a tunable Coherent Chameleon Discovery femtosecond laser (680–1300 nm, 80 MHz, 100–150 fs, 13–16 nm spectral width; wavelength measured with a high-resolution spectrometer, APE waveScan) is attenuated by a half-wave plate and a polarizing beamsplitter cube, transmitted through an 805 nm longpass dichroic mirror and focused by an Olympus Plan N 40×/0.65 objective. The photoluminescence returns through the objective, is reflected by the dichroic mirror and integrated over 690–750 nm on an avalanche photodiode. Continuous microwaves (15 dBm), modulated at 50 Hz by the lock-in reference, are delivered by a wire loop; details are given in the Supplemental Material (SM) [21]. At each wavelength the photoluminescence SS (minus the laser-blocked dark level) and the spin signal ΔS\Delta S (the decrease of SS on resonance) are read at the same setting, one immediately after the other; the contrast is C=ΔS/SC=\Delta S/S. All data are taken at room temperature.

Figure 2 shows a wavelength scan at 300 mW across 1027–1130 nm. SS and ΔS\Delta S peak together at 1060–1075 nm (a). The contrast is lowest there (b): 1.27–1.30% against 1.55–1.60% at 1030–1040 nm. The shot-noise figure of merit ΔS/S=CS\Delta S/\sqrt{S}=C\sqrt{S}, however, peaks in the same window (c), at 91.7–92.2 against 72.6 at 1040 nm (+26%) and 66.8 at 1030 nm (+37%). The resonances are those of NV−^- [(d); D=2868.74D=2868.74 MHz, 2E=11.22E=11.2 MHz].

Figure 2. Wavelength scan at 300 mW. (a) Photoluminescence SS and spin signal ΔS\Delta S, relative to 1075 nm; top axis, photon energy. (b) Contrast C=ΔS/SC = \Delta S/S. (c) Shot-noise figure of merit ΔS/S\Delta S/\sqrt{S}. Green band, 1060–1075 nm. (d) ODMR spectrum at 1075 nm (lock-in signal, in phase; the photoluminescence decreases on resonance).

Spin contrast at equal photoluminescence. The raw contrast mixes two effects: CC falls as SS rises, and both change with wavelength. We therefore compare each point with the contrast measured at 1075 nm at the same SS, by varying the power from 88 to 300 mW [Fig. 3(a)], and define the contrast loss at equal photoluminescence

L=1−C/C1075(S).L=1-C/C_{1075}(S).

A loss channel that is absent at 1075 nm appears as L>0L>0.

Rate model. To relate the contrast loss to the channels of Figure 1 we use a rate model of the NV center in both charge states, NV−^- and NV0^0 [Fig. 1(c)]. It follows the populations of ten levels: the ms=0m_s=0 and ±1\pm1 sublevels of 3A2^3A_2 and 3E^3E, the singlets 1A1^1A_1 and 1E^1E, the 2E^2E and 2A2^2A_2 states of NV0^0, and the ms=±1/2m_s=\pm1/2 and ±3/2\pm3/2 sublevels of 4A2^4A_2. Each laser pulse is much shorter than any decay and is treated as instantaneous: it transfers population with probabilities set by the photon fluence and the cross sections of the two-photon excitations and of the ionization and recharge channels, including the ionization of 3E^3E excited by the same pulse; the lowest triplet above 3E^3E lies 2.385 eV higher [22], so 3E^3E absorbs our photons only into the continuum. The cross sections depend on the photon energy through their zero-phonon thresholds, broadened by the calculated phonon sidebands [10], an inhomogeneous width and the laser spectrum. Between pulses the populations follow linear rate equations for radiative decay, intersystem crossing, the decay of the singlets and of the quartet, spin–lattice relaxation, the microwave drive, electron transfer from 3E^3E to nearby nitrogen donors, and the return of NV0\mathrm{NV}^{0} to NV−\mathrm{NV}^{-} by electron tunnelling from the donors, with the distribution of tunnelling rates set by the random distance to the nearest donor at [N] = 10 ppm [23]. The steady state of the 80 MHz pulse train is the fixed point of the map over one period, found numerically. The photoluminescence follows from the radiative decays of 3E^3E and 2A2^2A_2, weighted by their emission into the detection window; SS and CC are obtained with and without microwaves and averaged over the intensity profile of the focus. The rate equations, the rates and cross sections with their sources, and the numerical methods are given in Ref. [21].

The contrast loss is zero within 1% at 1060–1075 nm and rises on both sides [Fig. 3(b)]. We fit the model to 52 contrast-loss values measured at 150–300 mW [21]; each value carries an uncertainty of 1.5%, set by the choice of the reference measurements. The free parameters are the strengths of channels A, Q and RqR_q, the two-photon absorption of NV0\mathrm{NV}^{0} and the NV0\mathrm{NV}^{0} share of the detected emission, with IP(3A2)\mathrm{IP}(^3A_2) fixed at the value obtained together with the scan of Figure 4, and EqE_q scanned. With channel Q, and with the cross section of channel I tied to that of Q, σI=rσQ\sigma_I = r\sigma_Q, the model reproduces these values with a root-mean-square deviation of 1.4%, within that uncertainty, for Eq=1.23 eVE_q = 1.23\,\mathrm{eV} [Fig. 3(b)]. Without channel Q the deviation is 9.1%, up to 29% at the shortest wavelengths. The visible onset near 1055 nm is the tail of this zero-phonon threshold, broadened by the phonon sideband, an inhomogeneous width of 20 meV and the laser bandwidth. Inhomogeneous widths of 10–40 meV, ratios r=0.08r = 0.08–0.13 (r=0.28r = 0.28 fits worse) and a shift of IP by ±0.03 eV\pm0.03\,\mathrm{eV} move the best threshold within 1.215–1.245 eV; together this gives Eq=1.23±0.02 eVE_q = 1.23 \pm0.02\,\mathrm{eV}. The fits need a photo-recharge of 4A2^4A_2 (RqR_q), which we take at least as strong as channel A, as calculated for the corresponding one-photon transitions [24]; 4A2^4A_2 then stays below 0.4% populated, as assumed for green excitation [25].

Figure 4. (a) Scan at 40 mW: SS (squares) and CC (circles) relative to 980–1000 nm. Lines: model SS (black) and CC (orange) from the fit to both together with the contrast-loss values (solid, IP = 2.63 eV), and for a saturated ground-state channel (dashed, IP = 2.54 eV); top axis, two-photon energy. (b) Energy ladder of Eq. (1): IP(3A2{}^{3}A_{2}) from (a), EqE_q from Figure 3 and EZPLE_{\mathrm{ZPL}} give the quartet energy.

The long-wavelength side carries independent information. Beyond 1080 nm the two-photon absorption falls, and matching SS requires a higher photon flux per excitation, so any one-photon ionization of 3E^3E grows relative to 1075 nm. Channel Q is closed there. Without channel I the model gives L≈0L \approx0 at 1080–1130 nm, against 3–11% measured; the root-mean-square deviation of these 11 values grows from 1.7% to 6.9%, and that of all 52 values from 1.4% to 3.4%. The data thus require a 3E→NV0(2E)^3E \to\mathrm{NV}^{0}(^2E) channel with σI=(1.3\sigma_I = (1.3–2.3)×10−19 cm22.3) \times10^{-19}\,\mathrm{cm}^{2}, an order of magnitude below direct ionization into 4A2^4A_2 at equal excess energy but not negligible: it ionizes 11–22% of the excited 3E^3E per pulse. Beyond 1030 nm, where only the broadened tail of the Q onset remains, this is several times the fraction ionized into the quartet, so that channel I is the main ionization route of 3E^3E there. The correlated 2E^2E well accounts for it. A cavity experiment likewise requires 3E→2E^3E \to{}^2E ionization at 1524 nm, below the quartet threshold, about an order of magnitude weaker than 3E→4A2^3E \to{}^4A_2 [15].

Channels of the singlets

The singlet shelf of NV−\mathrm{NV}^{-} adds three channels in the same spectral range: ionization of the short-lived 1A1^1A_1 [26] after the 1E→1A1^1E \to{}^1A_1 resonance at 1042 nm [27, 28] [29, 30]; two-photon ionization of 1E^1E, whose one-photon threshold has been measured with visible light [31–33]; and recharge of excited NV0\mathrm{NV}^{0} into the singlets instead of 2A2^2A_2, whose threshold is known from transient absorption [34]. Their thresholds depend on the singlet–triplet gap and overlap with those of Q, RqR_q and I, and several of these processes act in parallel with partly opposite effects on the spin contrast. None of them leaves a separate signature within the 1.5% uncertainty, as three tests show [21]. (i) Ionization of 1A1^1A_1 would make the contrast loss at the 1042 nm resonance grow with power. We measure a growth of at most 6% (2σ2\sigma) from 150 to 300 mW, as expected without this route (+2.5%); this bounds the route to about a third or less of an estimate from the measured 1E→1A1^1E \to^1A_1 absorption, the selection rules and the calculated photoionization of 3A2^3A_2 [10]. (ii) Our photons (0.99–1.36 eV) lie below the one-photon threshold of 1E^1E, so 1E^1E is ionized only by nonresonant two-photon absorption; its cross section is below about 1 GM (Göpp ert-Mayer unit, 1 GM = 10−50 cm4s10^{-50}\,\mathrm{cm}^4\mathrm{s}; see SM [21]), comparable to the two-photon absorption of NV−^- [5, 18]. (iii) Recharge into the singlets does not improve the fit. These channels are therefore omitted from the fits shown here.

The photoluminescence step below 1060 nm [Fig. 1(d)], by a factor of 2.7 and independent of power from 100 to 500 mW, is not a charge-state effect in the model: a ten times stronger channel Q lowers S at 1030 nm by only 9% and removes most of the spin contrast. We assign it to the two-photon absorption spectrum of NV−^-, which is resolved here with a narrower source than in Ref. [18].

Ground-state threshold and the quartet energy. To obtain IP(3A2)\mathrm{IP}(^3A_2) we scanned 910–1000 nm at 40 mW [Fig. 4(a)]. At this power the charge cycling by two-photon excitation plus one-photon ionization, which scales with one more power of the intensity, is suppressed relative to the two-photon steps, so the edge is not masked by it. The contrast collapses at 940–960 nm to C≤0.09C \le0.09 of its value at 980–1000 nm, while SS keeps about one third. The contrast-loss values alone do not fix the threshold, which they trade against the strength of channel A; the edge does. Fitted jointly with them, it gives IP(3A2)=2.63±0.03\mathrm{IP}(^3A_2)=2.63\pm0.03 eV, with EqE_q unchanged, consistent with the photocurrent thresholds of 2.66(4) and 2.69(3) eV [24]. The edge could alternatively be read as the saturation of channel A, with its threshold well below the edge (IP=2.54\mathrm{IP}=2.54 eV). The best fit of this reading [dashed lines in Figure 4(a)] keeps the contrast below 930 nm at 0.32 of its value at 980–1000 nm, whereas the measured contrast falls to 0.06–0.09; this reading is therefore excluded [21].

Equation (1) then places the quartet at

E(4A2)−E(2E)=0.54±0.04 eV(2)E(^4A_2)-E(^2E)=0.54\pm0.04\,\mathrm{eV} \tag*{(2)}

[Fig. 4(b)], the uncertainties of EqE_q (±0.02\pm0.02 eV) and of IP(3A2)\mathrm{IP}(^3A_2) (±0.03\pm0.03 eV) being independent. Both thresholds come from the same spot, the same setup and the same temperature, so the temperature shift of the band edge enters both onsets alike, and both are zero-phonon thresholds. The value is consistent with the room-temperature bound of Ref. [15]: that bound, <0.58<0.58 eV, assumed IP(3A2)=2.65\mathrm{IP}(^3A_2)=2.65 eV, and with our IP the same argument gives ≤0.60\le0.60 eV. It is above the ≈0.4\approx0.4 eV estimate from separate photoionization experiments and within

the calculated range (0.48 eV, HSE06, and 0.58 eV, PBE [13]; 0.68 eV, configuration interaction [14]).

Optimum excitation. The window of the highest figure of merit, 1060–1075 nm, lies just beyond the broadened onset of channel Q and before the two-photon absorption falls; at 1060–1070 nm the contrast loss at equal SS is −1.0-1.0 to +1.8%+1.8\%. The figure of merit at 1075 nm grows as PP over 88–300 mW [21]. At 200 mW, 1075 nm exceeds 1030 nm by 46%. For a shot-noise-limited measurement, the gain of 26–37% over 1030–1040 nm, the wavelengths of Yb sources used so far [8], shortens the acquisition by a factor of 1.6–1.9 at equal power or, by the measured power law, allows 30–40% less power at equal sensitivity, while the water absorption is nearly the same (0.16 and 0.18 cm−1\mathrm{cm}^{-1} at 1040 and 1070 nm) [35]. As a consequence, both the excitation and the 637–800 nm emission lie inside the near-infrared transparency window of tissue.

Conclusion. Two-photon ODMR with a tunable source resolves the threshold of photoionization from the NV−^- excited state into the NV0^0 quartet, Eq=E_q=

1.23 ± 0.02 eV, and, with the ground-state threshold from the same setup, the quartet energy 0.54 ± 0.04 eV. The spin contrast also requires ionization of 3E{}^{3}E into the NV0^{0} ground state, which sets the loss beyond 1080 nm. The quartet threshold and the excitation spectrum together fix the optimum excitation at 1060–1075 nm, a recipe that applies to two-photon sensing with nanodiamonds in biological media.

Data availability. The data and the code of the rate model (GNU GPL v3.0) are openly available in the HUN-REN research data repository at doi:10.5158/ARP/T7NV6O.

Acknowledgments

This work was supported by the EUREKA project quNV2.0 (2021-17465/NP/BILAT_HU_DE_1, 2023–2026) via the National Research, Development and Innovation Office (NKFIH) under Grant No. 2020-1.2.3-EUREKA-2022-00022. A.G. acknowledges funding from the European Commission through the QuS-PARC (Grant No. 101186889) and SPINUS (Grant No. 101135699) projects. We used the AI assistant Claude (Anthropic; Opus 4.8, 5 and 5.5, Fable 5 and 5.1) under the authors’ direction to write the code for the simulations, fits and figures, to structure and analyze the data, and to contribute to drafting and editing the text [21]. The authors specified the model and the analysis, checked all equations, inspected all fits and figures, and take full responsibility for the content.

† [email protected]

References

Supplemental Material: Quartet state of the neutral nitrogen–vacancy center in diamond and optimized spin readout under near-infrared two-photon excitation

Nikoletta Jegenyes; Pál Maák; Vladimir Verkhovlyuk; László Himics; Tamás Váczi; Miklós Veres; Adám Gali

Sample and setup

Sample. The sample is a 3×33 \times3 mm2^{2}, 0.30.3 mm thick (100) diamond plate grown by chemical vapor deposition, with a nominal nitrogen concentration of 10 ppm and an NV ensemble formed during growth (≈0.1\approx0.1 ppm). All data were taken at room temperature.

Optics. The beam of a Coherent Chameleon Discovery femtosecond laser (680–1300 nm, 80 MHz, 100–150 fs) is attenuated by a broadband half-wave plate and a polarizing beamsplitter cube, transmitted through a Thorlabs DMLP805 longpass dichroic mirror and focused by an Olympus Plan N 40×/0.65 objective. Dispersion lengthens the pulse to ≥300\ge300 fs at the sample. Powers are measured before the objective; the model takes an estimated 0.8 of this power at the focus (Table S2), and 0.9 for the scan below 1000 nm (S6). The photoluminescence is collected by the same objective, reflected by the dichroic mirror, filtered by an FELH550 longpass, an FES800 shortpass and a 690–750 nm bandpass, and detected by a Thorlabs APD410A/M avalanche photodiode. SS is the dc level of the photodiode minus the laser-blocked dark level, read at every point.

Wavelength scale and pulse spectrum. The wavelength and the laser spectrum are measured with a high-resolution spectrometer (APE waveScan); all wavelengths of the main text and of this SM are on this scale. The spectra have a full width at half maximum of 11–18 nm (mean 15 nm at 975–1130 nm, 12 nm at 910–1000 nm).

Microwaves and lock-in detection. An HP 8753C source (15 dBm) drives a wire loop at the sample. Its output is modulated with a 50 Hz sine wave by the internal reference of a Zurich Instruments MFLI lock-in amplifier, which demodulates the photodiode signal (time constant 500 ms; 50–200 averages per spectrum). The lock-in phase is fixed for each wavelength scan and set from a full spectrum at 1075 nm, so that the resonance lies in the in-phase component. On resonance the photoluminescence decreases, and the spectra are plotted with this sign (dips). The spin signal ΔS\Delta S is the magnitude of this decrease, the in-phase amplitude of the resonance, from a full spectrum or from an on-resonance record minus the off-resonance record of the same setting; the contrast C=ΔS/SC = \Delta S/S is thus positive. The modulation frequency is low because the spin signal follows the microwaves with an effective response time of 0.5–1 ms, measured on this sample under two-photon excitation at 30–50 mW with the frequency-domain method of Ref. [1], which also gives its spin–lattice relaxation time T1=4.75T_{1} = 4.75 ms; at 50 Hz at least 95% of the signal is kept, at 1 kHz only a fraction of it. Although 50 Hz coincides with the mains frequency, pickup is below 0.1 μ\muV: spectra without a resonance are flat to ±0.06\pm0.06 μ\muV. SS and ΔS\Delta S are read at the same setting of wavelength and power, one immediately after the other.

Representative ODMR spectra

Figure S1 shows representative spectra. The ensemble gives a strain-split doublet with equal amplitudes of its two lines (ratio 0.98±0.020.98 \pm0.02 at 995–1033 nm). At 1075 nm and 150–300 mW, D=2868.74D = 2868.74–2869.08 MHz, 2E=11.22E = 11.2–11.5 MHz and the full width at half maximum is 6.9–7.2 MHz; at 995–1033 nm and 200 mW, D=2869.08D = 2869.08–2869.22 MHz, 2E=11.52E = 11.5–11.8 MHz and 7.5–8.0 MHz; at 40 mW, D=2869.76D = 2869.76–2870.18 MHz, 2E=12.72E = 12.7–13.4 MHz and 9.1–10.3 MHz. At a given power the line positions and widths do not change with wavelength, so the wavelength dependence of ΔS\Delta S is that of its amplitude. At 40 mW the resonance is clearly visible and can be fitted at every wavelength from 1000 nm down to 950 nm; at 940 nm it is only 3.6σ\sigma above the noise, and at 910–930 nm it is not significant (≤2σ\le2\sigma) [Fig. S1(b)].

Two-photon-excited ODMR spectra

Figure S1. Two-photon-excited ODMR spectra (lock-in signal in phase, off-resonance level removed; negative, a decrease of the photoluminescence). (a) 1075 nm at 300 and 150 mW and 995, 1015 and 1033 nm at 200 mW. (b) 40 mW across the ground-state threshold, 1000–920 nm.

Contrast loss at equal photoluminescence

Reference curve. At 1075 nm the contrast falls from 2.13% to 1.30% as SS rises from 3.9 to 50 mV (88–300 mW). The reference points are measured together with the wavelength scans and fitted as

ln⁡C1075(S)=a+bln⁡S+c(ln⁡S)2,(3)\ln C_{1075}(S) = a + b\ln S + c(\ln S)^2, \tag*{(3)}

with SS in mV and a common shape, b=0.0932b = 0.0932 and c=−0.0567c = -0.0567. Because the absolute contrast depends on the alignment, the level aa is fitted separately for the reference points measured with each wavelength scan (a=−3.880a = -3.880 and −3.855-3.855; the levels differ by 2.5%, and by 0.1% where a single reference point sets the level). The root-mean-square residual is 1.3%. Each measured point is compared with the curve measured together with it, at its own SS,

L=1−C(λ,P)C1075(S),(4)L = 1 - \frac{C(\lambda,P)}{C_{1075}(S)}, \tag*{(4)}

so that LL contains only the change of the contrast with wavelength at equal photoluminescence. The 300 mW scan reaches S=52S = 52 mV at 1065–1070 nm, 4% beyond the largest reference point.

Uncertainty. Four estimates agree: the residual of the reference fit (1.3%); the change of LL when one reference point is omitted (up to 1.1%); the agreement of repeated settings (0.5–1.2% in CC at 300 mW, 1–3% at 150 mW); and a repeated scan at 200 mW, whose LL values at seven common wavelengths (995–1033 nm) differ by +1.6% on average with a standard deviation of 1.2%. We assign σ=1.5%\sigma= 1.5\% to each value; where a setting was measured twice (1030, 1042 and 1046 nm at 150 and 300 mW), σ\sigma combines half the spread of the two readings (at least 1%) and 1% for the reference.

Data. The 52 values are listed in Table S1 and are included as a data file with the code (S9).

PP (mW)λ\lambda (nm)LL (%)PP (mW)λ\lambda (nm)LL (%)PP (mW)λ\lambda (nm)LL (%)PP (mW)λ\lambda (nm)LL (%)
15010306.5±1.46.5 \pm1.4200100919.6±1.519.6 \pm1.520010336.0±1.56.0 \pm1.53001065−0.7±1.5-0.7 \pm1.5
15010423.2±1.83.2 \pm1.8200100922.6±1.522.6 \pm1.520010362.9±1.52.9 \pm1.53001070−1.0±1.5-1.0 \pm1.5
15010460.2±1.40.2 \pm1.4200101216.9±1.516.9 \pm1.5300102711.9±1.511.9 \pm1.530010802.9±1.52.9 \pm1.5
20097552.4±1.552.4 \pm1.5200101514.7±1.514.7 \pm1.530010309.6±1.59.6 \pm1.530010853.1±1.53.1 \pm1.5
20098046.9±1.546.9 \pm1.5200101516.5±1.516.5 \pm1.530010308.8±1.48.8 \pm1.430010903.0±1.53.0 \pm1.5
20098544.4±1.544.4 \pm1.5200101812.0±1.512.0 \pm1.530010356.8±1.56.8 \pm1.530010953.0±1.53.0 \pm1.5
20099039.1±1.539.1 \pm1.5200102111.3±1.511.3 \pm1.530010404.2±1.54.2 \pm1.530011003.7±1.53.7 \pm1.5
20099533.3±1.533.3 \pm1.5200102110.9±1.510.9 \pm1.530010424.6±1.44.6 \pm1.430011054.1±1.54.1 \pm1.5
20099535.3±1.535.3 \pm1.520010249.7±1.59.7 \pm1.530010452.3±1.52.3 \pm1.530011104.7±1.54.7 \pm1.5
200100028.1±1.528.1 \pm1.520010276.8±1.56.8 \pm1.530010461.9±1.41.9 \pm1.430011157.0±1.57.0 \pm1.5
200100326.2±1.526.2 \pm1.520010279.3±1.59.3 \pm1.530010501.8±1.51.8 \pm1.530011208.1±1.58.1 \pm1.5
200100326.5±1.526.5 \pm1.520010306.6±1.56.6 \pm1.530010554.6±1.54.6 \pm1.5300112510.2±1.510.2 \pm1.5
200100623.4±1.523.4 \pm1.520010334.2±1.54.2 \pm1.530010601.8±1.51.8 \pm1.5300113011.0±1.511.0 \pm1.5

Table S1. The 52 contrast-loss values L=1−C/C1075(S)L = 1 - C/C_{1075}(S) fitted in S4–S5 (power set before the objective).

Rate model

All parameters of the model, with their values and sources, are collected in Table S2; the three input curves are shown in Figure S3.

Two-photon absorption cross section of NV−

(a)

Calculated photoionization cross sections of ${}^{3}A_{2}$ and ${}^{3}E$

(b)

Construction of the ${}^{1}A_{1}$ ionization cross section

(c)

Figure S3. Input curves of the rate model, as read by the code ((S9)). (a) Two-photon absorption cross section of NV−\mathrm{NV}^{-}: circles, the points digitized from Fig. 6 of Ref. [3] (calibrated there to 0.45 GM at 1060 nm [17]); dashed, the continuation assumed where no data exist. (b) Calculated photoionization cross sections of 3A2{}^{3}A_{2} and 3E{}^{3}E without vibrational broadening, against the excess energy above threshold, read from Fig. 7 of Ref. [2]; the model uses their shapes normalized at 0.10 eV (dotted line), with the strengths of channels A, Q and RqR_{q} fitted ((S4.2)). (c) Construction of the 1A1{}^{1}A_{1} ionization cross section, which is derived, not calculated ((S7)): the 3A2{}^{3}A_{2} curve of (b) shifted to the 1A1{}^{1}A_{1} threshold E0=IP−ΔST−1.190E_{0} = \mathrm{IP} - \Delta_{\mathrm{ST}} - 1.190 eV (dotted; ΔST=0.36\Delta_{\mathrm{ST}} = 0.36 eV), times the one-electron weight 0.9×0.71=0.640.9 \times0.71 = 0.64 (dashed), times the photon-energy factor ℏω/(IP+ε)\hbar\omega/(\mathrm{IP} + \varepsilon) (solid, the cross section used). Gray band, photon energies of the scans; dashed line, the 1E→1A1{}^{1}E \to{}^{1}A_{1} resonance (1042 nm).

Levels and assumptions

The model follows one NV center, in either charge state, together with its nitrogen environment. The populations n=(ng0,ng1,ne0,ne1,nA,ns,n2E,n2A,nq1,nq3)\mathbf{n} = (n_{g0}, n_{g1}, n_{e0}, n_{e1}, n_A, n_s, n_{2E}, n_{2A}, n_{q1}, n_{q3}) are those of 3A2{}^{3}A_2 (ms=0m_s = 0; ms=±1m_s = \pm1 together), 3E{}^{3}E (ms=0m_s = 0; ms=±1m_s = \pm1), the singlets 1A1{}^{1}A_1 and 1E{}^{1}E of NV−^{-}, the 2E{}^{2}E and 2A2{}^{2}A_2 states of NV0^{0}, and the ms=±1/2m_s = \pm1/2 and ±3/2\pm3/2 sublevels of the NV0^{0} quartet 4A2{}^{4}A_2; ∑ini=1\sum_i n_i = 1. The assumptions are:

  1. Each pulse (τ≈300\tau\approx300 fs at the focus) is much shorter than every lifetime and is treated as instantaneous. Within a pulse, a state created by two-photon excitation can absorb a further photon from the remainder of the same pulse; on average it sees half of the pulse fluence.

  1. The ms=±1m_s = \pm1 sublevels are treated together, hyperfine structure is not resolved, and the microwave drive is an incoherent rate WW between ms=0m_s = 0 and ms=±1m_s = \pm1 (on resonance). All rates are room-temperature values.

  1. Photoionization of 3E{}^{3}E into NV0(4A2)^{0}({}^{4}A_2) conserves the spin projection by the Clebsch–Gordan rule: ms=0m_s = 0 reaches ±1/2\pm1/2; ms=±1m_s = \pm1 reaches ±3/2\pm3/2 with weight 3/43/4 and ±1/2\pm1/2 with weight 1/41/4 [2]. Recharge into NV−^{-} produces 3A2{}^{3}A_2 with random msm_s (weights 1/31/3, 2/32/3), or, for electron capture by 2E{}^{2}E, the singlet manifold with the statistical weight ws=1/4w_s = 1/4.

  1. The environment consists of substitutional nitrogen donors at the density [N]; interactions between NV centers are neglected ([NV] ≪\ll [N]). An NV center returns from NV0^{0} to NV−^{-} by electron tunnelling from its nearest donor, at a rate set by the donor distance; the ensemble is a sum over donor-distance classes (S4.5).

  1. The focal average is taken over the radial intensity profile of a Gaussian focus only.

  1. The detected photoluminescence is the emission of NV−^{-} and NV0^{0} into the detection window with constant fractions f−f_{-} and f0f_0; its absolute scale is not used.

Final state of channel Q. An onset near 1.2 eV requires a final state of NV0^{0} about 0.5 eV above 2E{}^{2}E [Eq. (1) of the main text]. Photoionization of 3E{}^{3}E (a1e3a_1e^3) removes one electron, and the one-electron selection rule restricts the final state to the a1e2a_1e^2 configuration, whose multiplets are 4A2{}^{4}A_2, 2A2{}^{2}A_2, 2E{}^{2}E and 2A1{}^{2}A_1. Of these, 2A2{}^{2}A_2 lies 2.156 eV above 2E{}^{2}E, and by Hund’s rule the quartet is the lowest in energy. The final state is therefore 4A2{}^{4}A_2.

Photon fluence and cross sections

Pulse quantities. A pulse enters the model through the photon flux F(t)F(t) at the centre of the focus (photons per unit area and time). A one-photon step of cross section σ\sigma (cm2^2) proceeds at the rate σF(t)\sigma F(t), and a two-photon step of cross section σ2\sigma_2 at the rate σ2F(t)2\sigma_2 F(t)^2; σ2\sigma_2 has units of cm4^4 s and is quoted in Göppert-Mayer units, 1 GM=10−50 cm4s1\ \mathrm{GM}=10^{-50}\ \mathrm{cm}^4\mathrm{s}. Integrated over a pulse, the two steps therefore depend on two different quantities: the photon fluence Φ=∫F dt\Phi=\int F\,dt (photons per unit area per pulse) and ∫F2 dt\int F^2\,dt. Both follow from three assumptions. (i) Each pulse carries the energy P/frepP/f_{\mathrm{rep}}, i.e. N=P/(frepℏω)N=P/(f_{\mathrm{rep}}\hbar\omega) photons, for an average power PP at the focus and a repetition rate frepf_{\mathrm{rep}}. (ii) The focus is Gaussian, with the transverse profile e−2r2/w02e^{-2r^2/w_0^2} of 1/e21/e^2 radius w0w_0; its area integral is πw02/2\pi w_0^2/2, so the fluence at the centre is Φ=2N/(πw02)\Phi=2N/(\pi w_0^2). For a focus formed by the same objective at all wavelengths, w0w_0 scales with the wavelength, w0(λ)=w0(1040 nm) λ/1040 nmw_0(\lambda)=w_0(1040\ \mathrm{nm})\,\lambda/1040\ \mathrm{nm}. (iii) The temporal envelope is Gaussian with full width at half maximum τ\tau, F(t)=Φf(t)F(t)=\Phi f(t) with f(t)=(2/τ)ln⁡2/π e−4ln⁡2 t2/τ2f(t)=(2/\tau)\sqrt{\ln2/\pi}\,e^{-4\ln2\,t^2/\tau^2} and ∫f dt=1\int f\,dt=1; then ∫f2dt=2ln⁡2/π/τ=0.664/τ\int f^2dt=\sqrt{2\ln2/\pi}/\tau=0.664/\tau. Together,

Φ=2Pfrepℏωπw02,∫F2dt=0.664Φ2τ.(5)\Phi=\frac{2P}{f_{\mathrm{rep}}\hbar\omega\pi w_0^2},\qquad\int F^2dt=0.664\frac{\Phi^2}{\tau}. \tag*{(5)}

With first-order kinetics during the pulse, a two-photon step then occurs with the probability 1−exp⁡(−σ2∫F2dt)1-\exp(-\sigma_2\int F^2dt) and a one-photon step of a state present before the pulse with 1−exp⁡(−σΦ)1-\exp(-\sigma\Phi) (S4.3). A state created during the pulse by two-photon excitation, at a rate ∝F2(t)\propto F^2(t), sees only the photons that arrive after it is created; for a pulse symmetric in time this is on average half of the fluence, hence σΦ/2\sigma\Phi/2 for the ionization of 3E^3E and the recharge of 2A2^2A_2 in S4.3. As an example, 300 mW at the focus at 1040 nm, with frep=80f_{\mathrm{rep}}=80 MHz, w0=0.65 μmw_0=0.65\ \mu\mathrm{m} and τ=300\tau=300 fs, gives Φ=3.0×1018 cm−2\Phi=3.0\times10^{18}\ \mathrm{cm}^{-2} and ∫F2dt=1.9×1049 cm−4s−1\int F^2dt=1.9\times10^{49}\ \mathrm{cm}^{-4}\mathrm{s}^{-1}, so that a two-photon cross section of 1 GM excites with a probability of about 0.18 per pulse. The two-photon absorption of NV−^-, σ2−(λ)\sigma_2^-(\lambda), is the measured spectrum of Ref. [3] [Figure S3]. That of NV0^0 is a vibronic band with zero-phonon line EZPL0=2.156 eVE_{\mathrm{ZPL}}^0=2.156\ \mathrm{eV},

σ20(λ)=r0σ2−(1040 nm)B(2ℏω)B(2ℏω1040),B(E)=∑n≥0e−s0s0nn!G(E−EZPL0−nℏΩ0;sn).(6)\sigma_2^0(\lambda)=r_0\sigma_2^-(1040\ \mathrm{nm})\frac{B(2\hbar\omega)}{B(2\hbar\omega_{1040})},\qquad B(E)=\sum_{n\geq0}e^{-s_0}\frac{s_0^n}{n!}G(E-E_{\mathrm{ZPL}}^0-n\hbar\Omega_0;s_n). \tag*{(6)}

with G(x;s)G(x;s) a normalized Gaussian of width 4 meV for n=0n=0 and s0s_0 (Table S2) for n≥1n\geq1. Every photoionization and recharge channel has a threshold EthE_{\mathrm{th}} and an excess-energy dependence g(ϵ)g(\epsilon): the calculated cross section without vibrational broadening from Fig. 7 of Ref. [2] (read from the vector graphics of the published figure; Figure S3), that of 3E^3E for the ionization of 3E^3E (channel Q) and that of 3A2^3A_2 for all other channels. It is normalized to g(0.10 eV)=1g(0.10\ \mathrm{eV})=1, so that the fitted strength σ(0)\sigma^{(0)} is the electronic cross section 0.10 eV above threshold. This applies to channel A (3A2+2ℏω→NV0(2E)+e−^3A_2+2\hbar\omega\to\mathrm{NV}^0(^2E)+e^-, threshold EthE_{\mathrm{th}}), channel Q (3E+ℏω→NV0(4A2)+e−^3E+\hbar\omega\to\mathrm{NV}^0(^4A_2)+e^-, threshold EqE_q) and channel Rq (4A2+2ℏω→NV−(3A2)+h+^4A_2+2\hbar\omega\to\mathrm{NV}^-({}^3A_2)+h^+, threshold Eg−Eq−EZPLE_g-E_q-E_{\mathrm{ZPL}}). An independent calculation of the ionization of NV−^- [4] (dielectric function from PBE Kohn–Sham orbitals in a 512-atom supercell, threshold shifted to the HSE06 Δ\DeltaSCF value) has the same shape as the 3A2^3A_2 curve used here within 6% at 0.3–1.4 eV above threshold, once the thresholds are aligned, and a magnitude 1.7 times larger. Closer to threshold the two cannot be compared, because there the intra-defect a1→ea_1\to e transition dominates the calculated dielectric function.

Vibronic onsets of channels A and Q. For these two channels the threshold is the zero-phonon threshold, and the vibrational broadening enters as the convolution of gg with the spectral function of electron–phonon coupling AT(ϵ)A_T(\epsilon), as in Eq. (4) of Ref. [2]. For one photon,

σ(ℏω)=σ(0)⟨gvib(ℏω+x−Eth)⟩x,gvib(δ)=∫AT(ϵ)g(δ−ϵ) dϵ,x∼G(x;sinh2+sL2),sL=ℏΔλ2.355λ.(7)\sigma(\hbar\omega)=\sigma^{(0)}\langle g_{\mathrm{vib}}(\hbar\omega+x-E_{\mathrm{th}})\rangle_x,\qquad g_{\mathrm{vib}}(\delta)=\int A_T(\epsilon)g(\delta-\epsilon)\,d\epsilon,\qquad x\sim G\left(x;\sqrt{s_{\mathrm{inh}}^2+s_L^2}\right),\qquad s_L=\frac{\hbar\Delta\lambda}{2.355\lambda}. \tag*{(7)}

where Δλ\Delta\lambda is the full width at half maximum of the laser spectrum and 2.355=22ln⁡22.355=2\sqrt{2\ln2} converts it to the standard deviation of the Gaussian GG, and for two photons (channel A) the same with 2ℏω2\hbar\omega and 2sL\sqrt{2}s_L. The ingredients, shown in Figure S2, are:

Vibronic onsets of channels A and Q

Figure S2. Vibronic onsets of channels A and Q (S4.2). (a) Spectral functions of electron–phonon coupling of 3A2→2E^{3}A_{2} \to{}^{2}E (A) and 3E→4A2^{3}E \to{}^{4}A_{2} (Q) calculated in [2], at 0 K (dotted, with the multiphonon tail beyond 0.30 eV) and at 300 K (solid, as used); the zero-phonon lines are clipped. (b,c) Onsets of A and Q against the energy above the zero-phonon threshold: calculated electronic cross section without vibrational broadening (dotted), its convolution with the 300 K spectral function (dashed), and the cross section used in the fit, with the inhomogeneous width of 20 meV and the laser spectrum (solid). (d) Check of the convolution at 0 K: broadened cross sections of 3A2^{3}A_{2} and 3E^{3}E published in Fig. 7 of Ref. [2] (thick) and our convolution of the published unbroadened ones with the spectral functions of (a) (dashed).

  • The spectral functions at 0 K, A0(ϵ)A_0(\epsilon), of 3A2→2E^3A_2\to{}^2E (channel A) and 3E→4A2^3E\to{}^4A_2 (channel Q) calculated in Ref. [2]: the a1a_1 modes from the generating function and the ee modes, which couple through the dynamical Jahn–Teller effect of 2E^2E and 3E^3E, from a multi-mode Jahn–Teller treatment. They are read from the published figures up to 0.30 eV and continued beyond the multiphonon tail of linear coupling; the clipped zero-phonon line carries the remaining weight, 0.349 (A) and 0.390 (Q). As a check, the convolution of the published cross sections without broadening with A0A_0 reproduces the published broadened cross sections (Fig. 7 of Ref. [2]) within 4%, and their onsets within 12 meV.

  • Room temperature: AT=A0∗BTA_T = A_0 * B_T, with the thermal kernel of linear coupling

BT(ϵ)=12πℏ∫dt eiϵt/ℏexp⁡[∑jSjnj(2cos⁡ωjt−2)]B_T(\epsilon) = \frac{1}{2\pi\hbar} \int dt\,e^{i\epsilon t/\hbar}\exp\left[\sum_j S_j n_j(2\cos\omega_j t - 2)\right]

over the calculated spectral densities S(ℏω)S(\hbar\omega) [2] with Bose occupations njn_j at 300 K. This is exact for the a1a_1 modes and an approximation for the Jahn–Teller ee modes. At 300 K the zero-phonon weight drops to 0.22 (A) and 0.27 (Q), and about 7% of the weight lies below the zero-phonon line.

  • Near threshold the published curves contain a numerical smoothing of 30 meV [2]. We place their zero at the calculated thresholds (2.67 and 1.15 eV, 11 and 13 meV above the points where the curves leave the axis of the published figure) and use the near-threshold law g∝ϵ1/2g \propto\epsilon^{1/2} of Ref. [2] below 0.06 eV.

  • An inhomogeneous width sinhs_{\mathrm{inh}}, common to both thresholds, describes the spread of the local electrostatic and strain fields in the ensemble. The joint fit (S6) prefers sinh=20s_{\mathrm{inh}} = 20 meV among 0–40 meV; 10, 30 and 40 meV are tested in S5.

For channel RqR_q, for which no spectral function has been calculated, the phonon broadening is a Gaussian of width sph=30s_{\mathrm{ph}} = 30 meV: Eq. (7) with gg in place of gvibg_{\mathrm{vib}} and x∼G(x;sph2+2sL2)x \sim G(x;\sqrt{s_{\mathrm{ph}}^2 + 2s_L^2}). Channel I (3E+ℏω→NV0(2E)+e−{}^3E + \hbar\omega\to\mathrm{NV}^0({}^2E) + e^-) is open throughout the range (threshold ≈0.66\approx0.66 eV); its cross section is tied to that of Q, σI=rσQ(0)\sigma_I = r\sigma_Q^{(0)}. Two mechanisms can give this channel: direct ionization into the a1e2a_1e^2 component of the correlated 2E{}^2E ground state, which carries 8–28% of it [5], and an Auger process in which the photoexcited electron is recaptured into a1a_1 while an ee electron is emitted [6]; the rate of the latter has been argued to be strongly overestimated because the emitted electron leaves the defect before the capture [2]. In the direct picture rr is the admixture, and the fitted r=0.08r = 0.08–0.13 (S5) lies within the calculated range, so direct ionization alone accounts for the strength of the channel and no Auger process needs to be invoked. An Auger contribution of similar or smaller size would enter the same effective σI\sigma_I and cannot be excluded. The recharge of NV0(2A2)\mathrm{NV}^0({}^2A_2) into NV−(3A2)\mathrm{NV}^-({}^3A_2) (channel R, threshold ER=0.717E_R = 0.717 eV [7]) is

σR=σR(0)[ℏω−ERℏω1040−ER]0.33\sigma_R = \sigma_R^{(0)}\left[\frac{\hbar\omega- E_R}{\hbar\omega_{1040} - E_R}\right]^{0.33}

The pulse map

A pulse maps the populations as n→Mpn\mathbf{n} \to M_p\mathbf{n}. With the per-pulse probabilities

p−=1−e−σ−∫F2 dt,p0=1−e−σ0∫F2 dt,qA=1−e−σA∫F2 dt,qRq=1−e−σRq∫F2 dt,qI=1−e−σIΦ/2,qQ=1−e−σQΦ/2,qR=1−e−σRΦ/2,(8)\begin{aligned} p_- &= 1-e^{-\sigma_- \int F^2\,dt}, \qquad p_0 = 1-e^{-\sigma_0 \int F^2\,dt}, \qquad q_A = 1-e^{-\sigma_A \int F^2\,dt}, \qquad q_{R_q} = 1-e^{-\sigma_{R_q} \int F^2\,dt},\\ q_I &= 1-e^{-\sigma_I\Phi/2}, \qquad q_Q = 1-e^{-\sigma_Q\Phi/2}, \qquad q_R = 1-e^{-\sigma_R\Phi/2}, \tag*{(8)} \end{aligned}

and the fraction ftf_t of freshly excited 3E{}^3E that transfers its electron to a nearby donor within picoseconds, the pulse acts as follows (for ms=0m_s = 0 and ±1\pm1 separately).

  • Ground state: a fraction p−p_- is excited. Of the excited centers, (1−qI)(1−qQ)(1−ft)(1-q_I)(1-q_Q)(1-f_t) remain in 3E{}^3E with the same msm_s; qI+(1−qI)(1−qQ)ftq_I + (1-q_I)(1-q_Q)f_t end in NV0(2E)\mathrm{NV}^0({}^2E); (1−qI)qQ(1-q_I)q_Q end in 4A2{}^4A_2. Of the centers not excited, a fraction qAq_A is ionized into NV0(2E)\mathrm{NV}^0({}^2E).

  • 3E{}^3E present at the pulse: a fraction qIq_I ends in NV0(2E)\mathrm{NV}^0({}^2E) and (1−qI)qQ(1-q_I)q_Q in 4A2{}^4A_2.

  • 4A2{}^4A_2: a fraction qRqq_{R_q} is recharged into 3A2{}^3A_2 with random msm_s.

  • NV0(2E)\mathrm{NV}^0({}^2E): a fraction p0p_0 is excited; of these, qRq_R are recharged within the pulse, into 3A2{}^3A_2 (random msm_s) with weight 1−ws1-w_s and into 1E{}^1E with weight wsw_s; NV0(2A2)\mathrm{NV}^0({}^2A_2) present at the pulse is recharged with probability qRq_R in the same way.

The channels through the singlets (S7) add the excitation 1E→1A1{}^1E \to{}^1A_1 followed by ionization of 1A1{}^1A_1, two-photon ionization of 1E{}^1E, and recharge into 1E{}^1E and 1A1{}^1A_1; they are switched off in the fits of the main text.

Rate equations between pulses

Between pulses dn/dt=Kn\mathrm{d}n/\mathrm{d}t = \mathbf{K}\mathbf{n} with

n˙e0=−(kr+kISC,0+kt)ne0,n˙e1=−(kr+kISC,1+kt)ne1,n˙A=kISC,0ne0+kISC,1ne1−kA1nA,n˙s=kA1nA−ns/τs+wskdn2E,n˙g0=krne0+β0ns/τs−2(W+k1)ng0+(W+k1)ng1+13(1−ws)kdn2E+13qbkd(nq1+nq3),n˙g1=krne1+(1−β0)ns/τs+2(W+k1)ng0−(W+k1)ng1+23(1−ws)kdn2E+23qbkd(nq1+nq3),n˙2E=kt(ne0+ne1)+k02n2A+nq1/τq+ρnq3/τq−kdn2E,n˙2A=−k02n2A,n˙q1=−(1/τq+qbkd)nq1,n˙q3=−(ρ/τq+qbkd)nq3.(9)\begin{aligned} \dot{n}_{e0} &= -(k_{r}+k_{\mathrm{ISC},0}+k_{t})n_{e0}, & \dot{n}_{e1} &= -(k_{r}+k_{\mathrm{ISC},1}+k_{t})n_{e1}, \\ \dot{n}_{A} &= k_{\mathrm{ISC},0}n_{e0}+k_{\mathrm{ISC},1}n_{e1}-k_{A1}n_{A}, & \dot{n}_{s} &= k_{A1}n_{A}-n_{s}/\tau_{s}+w_{s}k_{d}n_{2E}, \\ \dot{n}_{g0} &= k_{r}n_{e0}+\beta_{0}n_{s}/\tau_{s}-2(W+k_{1})n_{g0}+(W+k_{1})n_{g1}+\frac{1}{3}(1-w_{s})k_{d}n_{2E}+\frac{1}{3}q_{b}k_{d}(n_{q1}+n_{q3}), \\ \dot{n}_{g1} &= k_{r}n_{e1}+(1-\beta_{0})n_{s}/\tau_{s}+2(W+k_{1})n_{g0}-(W+k_{1})n_{g1}+\frac{2}{3}(1-w_{s})k_{d}n_{2E}+\frac{2}{3}q_{b}k_{d}(n_{q1}+n_{q3}), \\ \dot{n}_{2E} &= k_{t}(n_{e0}+n_{e1})+k_{02}n_{2A}+n_{q1}/\tau_{q}+\rho n_{q3}/\tau_{q}-k_{d}n_{2E}, & \dot{n}_{2A} &= -k_{02}n_{2A}, \\ \dot{n}_{q1} &= -(1/\tau_{q}+q_{b}k_{d})n_{q1}, & \dot{n}_{q3} &= -(\rho/\tau_{q}+q_{b}k_{d})n_{q3}. \tag*{(9)} \end{aligned}

Here k1=1/T1k_{1}=1/T_{1}, WW is the microwave rate (zero with the microwaves off), ktk_{t} the slow electron transfer from 3E^{3}E to nitrogen, and kdk_{d} the tunnelling return of the center considered. Electron capture by the quartet is spin-blocked: only the fraction qb=3/8q_{b}=3/8 of the S=1S=1 and S=2S=2 pair states correlates with 3A2^{3}A_{2}.

Donor-distance distribution

The rate kdk_d in Eq. (9) is the return of NV0\mathrm{NV}^{0} to NV−\mathrm{NV}^{-} by tunnelling of an electron from a neutral substitutional nitrogen donor N0\mathrm{N}^{0} to the center. We take the model and parameters of Ref. [8], which were fitted there to the measured recovery of NV−\mathrm{NV}^{-} after photoionization in diamonds with 10 and 180 ppm nitrogen. The electron tunnels from the nearest donor, at distance RR; the process releases about 1 eV, which is taken up by the lattice, mainly through the relaxation of the donor on ionization. The rate has the form of a multiphonon transition,

kd(R)=2πℏW(R)2A,(10)k_d(R) = \frac{2\pi}{\hbar} W(R)^2 A, \tag*{(10)}

with an electronic and a vibrational factor.

  • W(R)W(R) is the electronic transfer (hopping) matrix element between the donor state and the NV level. Both defects are described in the zero-range-potential model: outside the defect core each bound wave function is that of a free particle of effective mass m∗m^{*}, ψi∝e−αiR/R\psi_i \propto e^{-\alpha_i R}/R, so that αi\alpha_i is the inverse decay length of the wave function. Here α1\alpha_1 refers to the N donor and α2\alpha_2 to the NV center, and

W(R)=ℏ2m∗Rα1α2α12−α22(α22e−α1R−α12e−α2R).(11)W(R) = \frac{\hbar^2}{m^{*}R}\frac{\sqrt{\alpha_1\alpha_2}}{\alpha_1^2-\alpha_2^2}\left(\alpha_2^2 e^{-\alpha_1 R}-\alpha_1^2 e^{-\alpha_2 R}\right). \tag*{(11)}

The effective mass m∗=0.57mem^{*} = 0.57m_e is the average conduction-band mass of diamond. The values α1=0.40\alpha_1 = 0.40 Å−1^{-1} and α2=0.89\alpha_2 = 0.89 Å−1^{-1} are the fitted values of Ref. [8]. They are comparable to the effective-mass estimates αi=2m∗∣Ei∣/ℏ\alpha_i = \sqrt{2m^{*}|E_i|}/\hbar of 0.51 and 0.64 Å−1^{-1} for the binding energies of 1.7 eV (N) and 2.6 eV (NV). At large RR the slower decay, α1\alpha_1, dominates, and kdk_d falls by about three orders of magnitude for every 8 Å.

  • AA is the vibrational factor: the phonon spectral function of the transition, i.e., the Franck–Condon-weighted density of final vibrational states, evaluated at the released energy. It is calculated in Ref. [8] from the configuration-coordinate potential-energy surfaces of N0\mathrm{N}^{0} and N+\mathrm{N}^{+}. Its value A=1.16A = 1.16 eV−1^{-1} at 300 K is almost that at 0 K, 1.19 eV−1^{-1}.

For a random distribution of donors at density nNn_{\mathrm{N}}, the probability that the nearest donor lies between RR and R+dRR+dR is

w(R) dR=4πR2nNexp⁡(−43πnNR3)dR.(12)w(R)\,dR = 4\pi R^2 n_{\mathrm{N}}\exp\left(-\frac{4}{3}\pi n_{\mathrm{N}}R^3\right)dR. \tag*{(12)}

Here nNn_{\mathrm{N}} is the nitrogen concentration [N] = 10 ppm of the sample (1.76×10181.76 \times10^{18} cm−3^{-3}), for which w(R)w(R) peaks at R=45R = 45 Å. Because kdk_d depends steeply on RR, the ensemble consists of centers whose return rates span many orders of magnitude. We represent it by 12 classes of equal probability 1/121/12, obtained by ordering the centers by kdk_d; each class is assigned the probability-weighted geometric mean of kdk_d over its members. A class slower than 10310^3 s−1^{-1} does not return within the measurement and is given kd=0k_d = 0; such classes are merged. At 10 ppm nitrogen concentration, the return, with kd≈5×109k_d \approx5 \times10^9, 1×1061 \times10^6 and 1×1041 \times10^4 s−1^{-1} (nearest donor closer than about 23, 29 and 34 Å, respectively). The remaining 3/43/4 of the centers, whose nearest donor is farther than about 34 Å, return to NV−\mathrm{NV}^{-} only through the optical recharge channels R and Rq_q. The signals are averaged over the classes with their weights wcw_c (S4.6).

Steady state, signals and contrast loss

The populations just before a pulse are periodic, nss=eK/frepMpnss\mathbf{n}_{\mathrm{ss}} = e^{K/f_{\mathrm{rep}}}M_p\mathbf{n}_{\mathrm{ss}}. With n+=Mpnss\mathbf{n}^{+} = M_p\mathbf{n}_{\mathrm{ss}} the populations just after the pulse, the detected photons per pulse are

N=f−∑mskrkr+kISC,ms+ktne,ms++f0η0n2A+.(13)N = f_{-}\sum_{m_s}\frac{k_r}{k_r+k_{\mathrm{ISC},m_s}+k_t}n^{+}_{e,m_s}+f_0\eta_0 n^{+}_{2A}. \tag*{(13)}

At a point of the focus with local average power uPuP (u≤1u \le1), NN is evaluated with the microwaves off and on, and the signals are averaged over the radial profile of the Gaussian focus, whose area element is ∝du/u\propto du/u, and over the donor classes cc of weight wcw_c:

S=∑cwc∫umin⁡1Noff(uP;kd,c)duu,ΔS=S−∑cwc∫umin⁡1Non(uP;kd,c)duu,C=ΔSS.(14)S = \sum_c w_c\int_{u_{\min}}^1 N_{\mathrm{off}}(uP;k_{d,c})\frac{du}{u},\qquad\Delta S = S-\sum_c w_c\int_{u_{\min}}^1 N_{\mathrm{on}}(uP;k_{d,c})\frac{du}{u},\qquad C = \frac{\Delta S}{S}. \tag*{(14)}

with umin⁡=0.08u_{\min} = 0.08 (the edge of the region contributing to the two-photon signal). The model contrast loss is computed exactly as the measured one, L=1−C(λ,P)/C1075(S)L = 1-C(\lambda,P)/C_{1075}(S), where C1075(S)C_{1075}(S) is the model C(S)C(S) at 1075 nm over 20–400 mW, interpolated in ln⁡C\ln C against ln⁡S\ln S. Only LL, a ratio at equal photoluminescence, is compared with the data.

Microwave rate and damping factor. The microwave rate is calibrated to the measured microwave-power dependence of the spin signal, ΔS∝PMW0.40\Delta S \propto P_{\mathrm{MW}}^{0.40} at 1040 and 1060 nm: with W∝PMWW \propto P_{\mathrm{MW}} we use W=2.4×105 s−1W = 2.4 \times10^{5}\ \mathrm{s}^{-1}, for which the model of the final fit gives dln⁡ΔS/dln⁡W=0.40\mathrm{d}\ln\Delta S/\mathrm{d}\ln W = 0.40 and 0.42 at the two wavelengths (300 mW). The model then gives C=15.4%C = 15.4\% at 1075 nm and 300 mW, against 1.30% measured. The ratio, the damping factor η=0.085\eta= 0.085, collects the reductions of the measured contrast that the model does not describe; it multiplies ΔS\Delta S and CC and cancels in LL. It contains the lock-in detection of the sine-modulated signal: the fundamental has a root-mean-square amplitude of 0.27–0.35 of the on/off difference, 1/(22)=0.351/(2\sqrt{2}) = 0.35 for a signal that follows the modulation linearly and less for the sublinear dependence ΔS∝PMW0.40\Delta S \propto P_{\mathrm{MW}}^{0.40}, depending on how the source converts the modulation voltage into microwave power. The waveform does not affect the calibration of WW: for a power-law dependence the fundamental scales with the same exponent as the on/off difference. The remaining factor of 0.24–0.31 is the reduction of an ensemble measurement relative to the model of a single, ideally driven center: the inhomogeneous microwave field over the focus, the different microwave coupling of the four NV orientations, the unresolved hyperfine lines, and background light. η\eta is specific to a sample and setup and can be determined independently, from the absolute contrast at one wavelength and power; it does not enter any of the fits. The fitted threshold does not depend on WW within a factor of 3 around the calibrated value (Table S3).

FitBest EqE_q (eV)Deviation (%)
r=0.13r = 0.13 (main)1.2301.17
r=0.08r = 0.081.2301.19
r=0.28r = 0.281.2301.94
sinh=10s_{\mathrm{inh}} = 10 meV1.2151.41
sinh=30s_{\mathrm{inh}} = 30 meV1.2451.17
sinh=40s_{\mathrm{inh}} = 40 meV1.2451.37
W/3;3WW/3; 3W1.2301.16; 1.17
IP=2.60\mathrm{IP} = 2.60 eV; 2.66 eV1.2301.17; 1.18
RqR_q held at 10 GM1.2301.22
Gaussian onsets, sph=30s_{\mathrm{ph}} = 30 meV1.2301.25
Gaussian onsets, sph=15s_{\mathrm{ph}} = 15 meV1.2152.49
channel I off (r=0r = 0)1.2303.29
no channel Q–9.11

Table S3. Fits of the 52 contrast-loss values (IP(3A2)=2.63\mathrm{IP}(^3A_2) = 2.63 eV, sinh=20s_{\mathrm{inh}} = 20 meV, W=2.4×105 s−1W = 2.4 \times10^5\ \mathrm{s}^{-1} unless stated, EqE_q scanned in steps of 15 meV): best threshold and root-mean-square deviation.

SymbolValueMeaningSource
frepf_{\mathrm{rep}}8×107 Hz8 \times10^{7}\ \mathrm{Hz}pulse repetition ratethis work
τ\tau3×10−13 s3 \times10^{-13}\ \mathrm{s}pulse duration (FWHM) at the focusthis work (100–150 fs at the source, lengthened by dispersion)
Δλ\Delta\lambda15 nmlaser spectral width (FWHM)this work (13–16 nm)
w0(1040 nm)w_{0}(1040\ \mathrm{nm})6.5×10−5 cm6.5 \times10^{-5}\ \mathrm{cm}1/e21/e^{2} focal radius at 1040 nm, scaled with the wavelengththis work (objective NA 0.65)
TT0.8fraction of the set power reaching the focusthis work (estimate)
krk_{r}6.5×107 s−16.5 \times10^{7}\ \mathrm{s}^{-1}radiative decay 3E→3A2{}^{3}E \to{}^{3}A_{2}Ref. [9]
kISC,0k_{\mathrm{ISC},0}8×106 s−18 \times10^{6}\ \mathrm{s}^{-1}intersystem crossing 3E(ms=0)→1A1{}^{3}E(m_{s}=0) \to{}^{1}A_{1}Ref. [9]
kISC,1k_{\mathrm{ISC},1}7.2×107 s−17.2 \times10^{7}\ \mathrm{s}^{-1}intersystem crossing 3E(ms=±1)→1A1{}^{3}E(m_{s}=\pm1) \to{}^{1}A_{1}Ref. [9]
kA1k_{A_{1}}1×1010 s−11 \times10^{10}\ \mathrm{s}^{-1}decay 1A1→1E{}^{1}A_{1} \to{}^{1}ERef. [10]
τS\tau_{S}2×10−7 s2 \times10^{-7}\ \mathrm{s}lifetime of 1E{}^{1}ERef. [11]
β0\beta_{0}0.8branching of 1E→3A2{}^{1}E \to{}^{3}A_{2} into ms=0m_{s}=0assumed (literature range 0.7–1.0)
k1=1/T1k_{1}=1/T_{1}210.5 s−1210.5\ \mathrm{s}^{-1}spin-lattice relaxation of 3A2{}^{3}A_{2}this sample: T1=4.75 msT_{1}=4.75\ \mathrm{ms} [1]
WW2.4×105 s−12.4 \times10^{5}\ \mathrm{s}^{-1}microwave rate ms=0↔±1m_{s}=0 \leftrightarrow\pm1 on resonance, microwaves onthis work: microwave-power dependence of ΔS\Delta S (S4.6)
k02k_{02}5×107 s−15 \times10^{7}\ \mathrm{s}^{-1}decay 2A2→2E{}^{2}A_{2} \to{}^{2}ERef. [7]
η0\eta_{0}1radiative quantum yield of 2A2{}^{2}A_{2}assumed
S0S_{0}3.9Huang–Rhys factor of the 2E→2A2{}^{2}E \to{}^{2}A_{2} bandRef. [5]
ℏΩ0\hbar\Omega_{0}0.065 eVphonon energy of the 2E→2A2{}^{2}E \to{}^{2}A_{2} bandassumed
s0s_{0}0.06 eVwidth of each vibronic replica of the 2E→2A2{}^{2}E \to{}^{2}A_{2} bandassumed
EZPL0E_{\mathrm{ZPL}}^{0}2.156 eVzero-phonon line of 2E→2A2{}^{2}E \to{}^{2}A_{2}Ref. [12]
f−f_{-}0.35fraction of the NV−^{-} emission in the detection windowband-shape estimate (690–750 nm)
f0f_{0}0.02166fraction of the NV0^{0} emission in the detection windowFIT
EZPLE_{\mathrm{ZPL}}1.945 eVzero-phonon line of 3A2→3E{}^{3}A_{2} \to{}^{3}ERef. [12]
EgE_{g}5.47 eVband gap of diamondroom-temperature value
IP(3A2)\mathrm{IP}({}^{3}A_{2})2.63 eVionization threshold of 3A2{}^{3}A_{2} (two photons)this work (joint fit with the 40 mW scan, S6)
r0r_{0}6.988two-photon absorption of NV0^{0} relative to NV−^{-} at 1040 nmFIT
σA(0)\sigma_{A}^{(0)}14.61 GMchannel A, 3A2+2ℏω→NV0(2E){}^{3}A_{2}+2\hbar\omega\to\mathrm{NV}^{0}({}^{2}E): cross section 0.10 eV above thresholdFIT
sphs_{\mathrm{ph}}0.03 eVGaussian phonon smearing of the RqR_{q} and singlet onsets (and of A with Gaussian onsets)assumed
EqE_{q}1.23 eVchannel Q, 3E+ℏω→NV0(4A2){}^{3}E+\hbar\omega\to\mathrm{NV}^{0}({}^{4}A_{2}): thresholdFIT (scanned)
σQ(0)\sigma_{Q}^{(0)}1.62×10−18 cm21.62 \times10^{-18}\ \mathrm{cm}^{2}channel Q: cross section 0.10 eV above thresholdFIT
sphQs_{\mathrm{ph}}^{Q}0.03 eVGaussian phonon smearing of the Q onset, used only with Gaussian onsets (test, S5)assumed

Table S2. Parameters of the rate model, as listed in the parameter file of the code (S9). FIT: fitted jointly to the 52 contrast-loss values and the 40 mW scan (fit at Eq=1.23E_{q}=1.23 eV, r=0.13r=0.13, IP(3A2)=2.63\mathrm{IP}({}^{3}A_{2})=2.63 eV, ssinh=20s_{\mathrm{sinh}}=20 meV).

SymbolValueMeaningSource
rr0.13channel I, 3E+ℏω→NV0(2E){}^{3}E + \hbar\omega\to\mathrm{NV}^{0}({}^{2}E): σI=r σA(0)\sigma_{\mathrm{I}} = r\,\sigma_{\mathrm{A}}^{(0)}a1e2a_{1}e^{2} admixture of 2E{}^{2}E, 8–28% [5]
ERE_{\mathrm{R}}0.717 eVchannel R, NV0(2A2)+ℏω→NV−(2A2)\mathrm{NV}^{0}({}^{2}A_{2}) + \hbar\omega\to\mathrm{NV}^{-}({}^{2}A_{2}): thresholdRef. [7]
σR(0)\sigma_{\mathrm{R}}^{(0)}5×10−195 \times10^{-19} cm2^{2}channel R: cross section at 1040 nmassumed
wsw_{\mathrm{s}}0.25fraction of electron captures that end in the singletsspin statistics
σRq(0)\sigma_{\mathrm{R}_{q}}^{(0)}14.61 GMchannel Rq_{q}, NV0(4A2)+2ℏω→NV−\mathrm{NV}^{0}({}^{4}A_{2}) + 2\hbar\omega\to\mathrm{NV}^{-}: cross section 0.10 eV above thresholdFIT, =κσA(0)= \kappa\sigma_{\mathrm{A}}^{(0)}
κ\kappa1strength of Rq_{q} relative to channel A, σRq(0)=κσA(0)\sigma_{\mathrm{R}_{q}}^{(0)} = \kappa\sigma_{\mathrm{A}}^{(0)}, FIT (at the limit 1); κ≥1\kappa\ge1 from calculated one-photon cross sections [4] (S5)fitted within 1–100
τq\tau_{q}3.3×10−63.3 \times10^{-6} slifetime of the ±1/2\pm1/2 sublevels of 4A2{}^{4}A_{2}geometric mean of the measured 1.78–6.06 μ\mus, room temperature [13]
ρ\rho3decay of the ±3/2\pm3/2 sublevels of 4A2{}^{4}A_{2} relative to ±1/2\pm1/2assumed
qbq_{b}0.375spin-allowed weight of electron capture by 4A2{}^{4}A_{2}spin statistics (3/8)
line shape1onsets of channels A and Q: 1, vibronic (S4.2); 0, Gaussianthis work
TvibT_{\mathrm{vib}}300 Ktemperature of the spectral functionsroom temperature
sinhs_{\mathrm{inh}}0.02 eVinhomogeneous width (Gaussian σ\sigma) of the thresholds of A and Qthis work (joint fit; tested 10–40 meV, S5)
wZPLAw_{\mathrm{ZPL}}^{\mathrm{A}}0.3487zero-phonon weight of the 0 K spectral function of channel A (3A2→2E{ }^{3}A_{2} \to{}^{2}E)normalization of the spectral function of Ref. [2] (S4.2)
wZPLQw_{\mathrm{ZPL}}^{\mathrm{Q}}0.3895zero-phonon weight of the 0 K spectral function of channel Q (3E→4A2{ }^{3}E \to{}^{4}A_{2})normalization of the spectral function of Ref. [2] (S4.2)
δA\delta_{\mathrm{A}}0.011 eVzero of the calculated 3A2{}^{3}A_{2} onset above the point where the published curve leaves its axiscalculated threshold 2.67 eV [2]
δQ\delta_{\mathrm{Q}}0.013 eVzero of the calculated 3E{}^{3}E onset above the point where the published curve leaves its axiscalculated threshold 1.15 eV [2]
ε1/2\varepsilon_{1/2}0.06 eVexcess energy below which the electronic onset follows ε1/2\varepsilon^{1/2}Ref. [2]
[N]10 ppmsubstitutional nitrogen (donor) densitygrowth specification
ftf_{t}0.01fast (ps) electron transfer 3E→N{}^{3}E \to\mathrm{N} per excitationRef. [7], scaled to [N]
ktk_{t}1.5×1051.5 \times10^{5} s−1^{-1}slow electron transfer 3E→N{}^{3}E \to\mathrm{N}Ref. [7], scaled to [N]
m∗m^{*}0.57 me0.57\,m_{e}effective mass in the donor-tunnelling modelRef. [8]
α1\alpha_{1}0.4 Å−1^{-1}decay constant 1 of the zero-range potentialRef. [8]
α2\alpha_{2}0.89 Å−1^{-1}decay constant 2 of the zero-range potentialRef. [8]
AA1.16 eV−1^{-1}vibronic overlap factor at 300 KRef. [8]
EA1E_{\mathrm{A1}}5 eVthreshold of 1A1+ℏω→NV0(2E){}^{1}A_{1} + \hbar\omega\to\mathrm{NV}^{0}({}^{2}E); 5 eV: channel closedoff in the fits; tested in S7
wA1w_{\mathrm{A1}}0.64ionization of 1A1{}^{1}A_{1} relative to that of 3A2{}^{3}A_{2} at equal excess energyselection rules and composition of 2E{}^{2}E [5]; a01e4a_{0}^{1}e^{4} share of 1A1{}^{1}A_{1}: estimate (S7)
ℏω\hbar\omega scaling13A2{}^{3}A_{2} value rescaled from its photon energy, IP + excess, to ℏω\hbar\omega (1: on)σ∝ℏω∣rij∣2\sigma\propto\hbar\omega\lvert r_{ij}\rvert^{2}, Eq. (3) of Ref. [2] (S7)
σsZPL\sigma_{\mathrm{s}}^{\mathrm{ZPL}}4×10−184 \times10^{-18} cm2^{2}peak cross section of the 1E→1A1{}^{1}E \to{}^{1}A_{1} zero-phonon line, room temperaturemeasured [14]; consistent with Ref. [15]
λs\lambda_{\mathrm{s}}1042 nm1E→1A1{}^{1}E \to{}^{1}A_{1} zero-phonon lineRef. [16]
Δλs\Delta\lambda_{\mathrm{s}}4 nmwidth of the 1E→1A1{}^{1}E \to{}^{1}A_{1} zero-phonon line, room temperatureassumed
ΔST\Delta_{\mathrm{ST}}0.36 eVenergy of 1E{}^{1}E above 3A2{}^{3}A_{2}, for the singlet thresholdsillustrative (S7)
SsS_{\mathrm{s}}0.9Huang–Rhys factor of the 1E→1A1{}^{1}E \to{}^{1}A_{1} sidebandRef. [14]
TsT_{\mathrm{s}}300 Ktemperature of the phonon occupation in the 1E→1A1{}^{1}E \to{}^{1}A_{1} sidebandthis work
bsb_{\mathrm{s}}5 meVadditional Gaussian broadening of the 1E→1A1{}^{1}E \to{}^{1}A_{1} sidebandassumed
σR1(0)\sigma_{\mathrm{R1}}^{(0)}0 cm2^{2}recharge NV0(2A2)→NV−(1E)\mathrm{NV}^{0}({}^{2}A_{2}) \to\mathrm{NV}^{-}({}^{1}E): cross section 0.10 eV above thresholdoff in the fits; tested in S7

Table S2 (continued).

SymbolValueMeaningSource
σRA(0)\sigma_{RA}^{(0)}0 GMrecharge NV0(2A2)→NV−(1A1)\mathrm{NV}^{0}({}^{2}A_{2}) \to\mathrm{NV}^{-}({}^{1}A_{1}); cross section 0.10 eV above thresholdoff in the fits; tested in S7
sRs_{R}0.03 eVphonon smearing of the recharge onsetsassumed
η\eta0.0846damping factor: measured over model contrast; multiplies ΔS\Delta S and CC, cancels in LL (S4.6)this work: 1.30% measured, 15.4% model at 1075 nm, 300 mW

Table S2 (continued, PDF p. 16).

Numerical Solution and Fitting

Steady state. The propagator over one period, eK/frepMpe^{K/f_{\mathrm{rep}}M_{p}}, is a 10 × 10 stochastic matrix; the matrix exponential is computed by scaling and squaring (Padé approximant), and nssn_{\mathrm{ss}} is its eigenvector with eigenvalue 1, normalized to unit sum. The focal integral is evaluated by Gauss–Legendre quadrature in t=ln⁡ut = \ln u with eight nodes; with four nodes LL changes by less than 0.01%, and the result agrees within 0.05% with an even grid of 96 points.

Fit. The model is fitted to the 52 contrast-loss values LiL_i of S3 by minimizing χ2=∑i(Limodel−Li)2/σi2\chi^2 = \sum_i (L_i^{\mathrm{model}} - L_i)^2/\sigma_i^2 with σi=1.5%\sigma_i = 1.5\% (values measured twice carry their own uncertainties). For 52 values and five free parameters, a model that describes the data within the stated uncertainty gives χ2≈47±10\chi^2 \approx47 \pm10. The fits of the 52 values alone give χ2=31\chi^2 = 31–33 (deviation 1.16–1.19%), so the 1.5% uncertainty is somewhat conservative; the joint fit of the main text gives χ2=45\chi^2 = 45 for them (1.40%). We regard differences Δχ2≤4\Delta\chi^2 \le4 between fits as not significant and Δχ2≳10\Delta\chi^2 \gtrsim10 as a clear preference. The free parameters are the strengths of channels A, Q and RqR_q (σA(0)\sigma_A^{(0)}, σQ(0)\sigma_Q^{(0)}, and κ\kappa in σR(0)=κσQ(0)\sigma_R^{(0)} = \kappa\sigma_Q^{(0)} with 1≤κ≤1001 \le\kappa\le100; see Fate of the quartet), the NV0\mathrm{NV}^{0} two-photon absorption r0r_0 and the NV0\mathrm{NV}^{0} emission fraction f0f_0; positive parameters are varied in log⁡10\log_{10}, within bounds, by a trust-region reflective least-squares method with a finite-difference Jacobian. The 52 values do not determine IP(3A2)\mathrm{IP}({}^{3}A_{2}), which they trade against the strength of channel A; it is fixed at 2.63 eV from the joint fit with the 40 mW scan (S6), and the fit shown in the main text and in Table S2 is that joint fit. The threshold EqE_q is not a free parameter: the fit surface is flat along EqE_q and correlated with σQ(0)\sigma_Q^{(0)}, so EqE_q is scanned on a grid (1.17–1.30 eV) and each grid point is fitted separately. The quality of a fit is quoted as the root-mean-square deviation [∑i(Limodel−Li)2/52]1/2\left[\sum_i (L_i^{\mathrm{model}} - L_i)^2/52\right]^{1/2}.

Tests. Table S3 lists the best threshold and the deviation of the fits for the ratio r=σI/σQr = \sigma_I/\sigma_Q, the inhomogeneous width sinhs_{\mathrm{inh}}, the microwave rate, IP\mathrm{IP}, a fixed fast RqR_q, the Gaussian onsets used before the vibronic line shape (S4.2), channel I switched off, and channel Q removed. Inhomogeneous widths of 10–40 meV are accepted, with the best threshold at 1.215–1.245 eV. Ratios r=0.08r = 0.08 and 0.13 fit equally well, 0.28 clearly worse. Neither the microwave rate (within a factor of 3 around its calibrated value, S4.6), nor IP\mathrm{IP} (within ±0.03\pm0.03 eV), nor a fixed RqR_q of 10 GM changes the threshold. Gaussian onsets of 30 meV give the same best threshold, 1.23 eV, and a sharp Gaussian onset (15 meV) is excluded. Over the accepted fits the best threshold lies in 1.215–1.245 eV, which gives Eq=1.23±0.02E_q = 1.23 \pm0.02 eV. Without channel I the long-wavelength contrast loss is not reproduced (main text); without channel Q the short-wavelength rise is not.

Fate of the quartet. Once formed, NV0(4A2)\mathrm{NV}^{0}(^4A_2) can return to NV−\mathrm{NV}^{-} by photo-recharge (RqR_q, threshold Eg−Eq−EZPL≈2.27E_g-E_q-E_{\mathrm{ZPL}} \approx2.27 eV, two photons here), by electron capture from a nearby donor (spin-blocked to the weight qbq_b), or decay to NV0(2E)\mathrm{NV}^{0}(^2E), which is spin-forbidden and must release about 0.6 eV. Table S4 lists refits of the 52 values at Eq=1.23E_q = 1.23 eV in which these routes are changed. Without photo-recharge the fit is clearly worse (Δχ2=8\Delta\chi^2 = 8). Its strength is hardly constrained by the 52 values: between 0.2 GM (free) and 10 GM, χ2\chi^2 changes by 3. The joint fit with the 40 mW scan prefers a weak recharge, 0.1 GM, by Δχ2≈18\Delta\chi^2 \approx18 over 10 GM. Such a weak recharge is not plausible physically: the recharge of 4A2^4A_2 into 3A2^3A_2 is fully allowed for direct ionization [5], and the calculated one-photon cross sections for the emission of a hole from NV0\mathrm{NV}^{0} exceed that for the ionization of 3A2^3A_2 above threshold [4]. In the dielectric functions of that calculation, the emission of a hole from NV0(2E)\mathrm{NV}^{0}(^2E) exceeds the ionization of NV−\mathrm{NV}^{-} by a factor of 3–7 at equal energy above the two thresholds, which lie within 0.1 eV of each other. We therefore take RqR_q at least as strong as channel A, σRq(0)=κσA(0)\sigma_{R_q}^{(0)} = \kappa\sigma_A^{(0)} with κ≥1\kappa\ge1, assuming that this ordering of the one-photon cross sections holds for the two-photon ones. The joint fit places κ\kappa at this limit, σRq(0)=σA(0)=15\sigma_{R_q}^{(0)} = \sigma_A^{(0)} = 15 GM; the 52 values then give χ2=45\chi^2 = 45, the value expected for them. The steady-state population of 4A2^4A_2 is then small: averaged over the focus, at most 0.4% at 975 nm and 300 mW, 0.06% at 1030 nm and 0.02% in the optimum window. With the weak recharge preferred without the constraint it would reach about 10% at 975–1000 nm; the resonance of 4A2^4A_2 at 2D ≈3.37\approx3.37 GHz (D=1685D = 1685 MHz [18]) would show it directly. The threshold and the quartet energy are the same in both cases: with RqR_q held at 10 GM the joint fit gives Eq=1.215E_q = 1.215–1.23 eV and a quartet energy of 0.50–0.55 eV. The decay time to 2E^2E, varied over the measured 1.78–6.06 μ\mus [13], does not affect the fit; equal decay of the two sublevel pairs is worse (Δχ2=8\Delta\chi^2 = 8). A small population of 4A2^4A_2 agrees with the calculation that the quartet lives for microseconds only in the dark [5], and with the rate model of one-photon green (520 nm) excitation in Ref. [19], which found no measurable population of 4A2^4A_2 and omitted it; there a single 2.38 eV photon already exceeds the threshold of RqR_q. Because RqR_q returns NV−\mathrm{NV}^{-} to 3A2^3A_2 with random msm_s, the cycle Q followed by RqR_q changes no charge state but randomizes the spin, at a rate that grows with intensity.

CaseDeviation (%)χ2\chi^2
RqR_q at least as strong as channel A (κ≥1\kappa\ge1; main)1.1731.7
RqR_q free, not tied to A (0.2 GM)1.1631.1
RqR_q held at 10 GM1.2234.4
RqR_q held at 1 GM1.1731.6
RqR_q switched off1.3139.6
decay time to 2E^2E 1.78 or 6.06 μ\mus (instead of 3.3 μ\mus)1.1731.7; 31.9
equal decay of both sublevel pairs (ρ=1\rho= 1)1.3139.7

Table S4. Refits of the 52 contrast-loss values at Eq=1.23E_q = 1.23 eV with the routes out of NV0(4A2)^0(^4A_2) changed.

Strength of channel I. The fitted σI=(1.3\sigma_I = (1.3–2.3)×10−19 cm22.3) \times10^{-19}\ \mathrm{cm}^2 is small relative to channel Q: σQ(0)\sigma_Q^{(0)} is 1.6×10−18 cm21.6 \times10^{-18}\ \mathrm{cm}^2 0.1 eV above its threshold, comparable to the calculated cross section of 3E^3E at that excess energy (9.3×10−19 cm29.3 \times10^{-19}\ \mathrm{cm}^2 [2]), whereas σI\sigma_I applies 0.4–0.6 eV above its own threshold, where the calculated cross section is 2–3 times larger. At equal excess energy, channel I is therefore about an order of magnitude below direct ionization into 4A2^4A_2, as expected for a channel that requires the minority a1e2a_1e^2 component of 2E^2E or a two-body process. For scale, the strongest optical transition of the center, the 3A2→3E^3A_2 \rightarrow^3E absorption of NV−^-, has σ=(3.1±0.8)×10−17 cm2\sigma= (3.1 \pm0.8) \times10^{-17}\ \mathrm{cm}^2 at 532 nm [17], about 20 times σQ(0)\sigma_Q^{(0)} and 130–240 times σI\sigma_I. In absolute terms it is not negligible: at 1030–1110 nm, where the onset of Q is only its broadened tail, channel I ionizes 11–22% of the freshly excited 3E^3E per pulse at 150–300 mW (centre of the focus), several times more than Q, and it is the main source of NV0(2E)^0(^2E) besides channel A and electron transfer to nitrogen (NV0^0 fraction 0.05–0.08 at 1030–1130 nm in the model).

This is consistent with the large NV0^0 fraction under one-photon green excitation, where the steady-state NV−^- population is at most 75% [20] (about 70% in Ref. [21]). There, channel Q can itself feed the NV0^0 ground state: the photo-recharge of 4A2^4A_2 needs 2.27 eV or more, so a 532 nm photon (2.33 eV) lies only about 0.06 eV above its threshold, and depending on the intensity part of the quartet population relaxes to 2E^2E within microseconds instead of being recharged [5]; ionization of 1E^1E, whose threshold is near 2.3 eV [22, 23], adds a further route. In the present pulsed experiment two photons of the same pulse recharge the quartet far above threshold, so Q returns the center to NV−^-, and a sizeable NV0^0 population requires channel I. The charge ratio under green light thus measures the sum of all routes into NV0(2E)^0(^2E), not the strength of channel I.

Comparison with other experiments. A cavity experiment with green light and an infrared field at 966 or 1524 nm, analysed with a rate model that resolves both charge states, reaches the same picture [13]. Ionization of 3E^3E into 4A2^4A_2 is driven by a single 966 nm photon (1.28 eV), which bounds the threshold of channel Q by 1.28 eV, consistent with Eq=1.23±0.02E_q = 1.23 \pm0.02 eV. At 1524 nm (0.81 eV), below that threshold, the charge-state dynamics require an effective one-photon ionization of 3E^3E, assigned there to an Auger process into 2E^2E; at both wavelengths the rates into 4A2^4A_2 exceed those into 2E^2E by an order of magnitude [13], as for channels Q and I here. We compare these ratios only, not the absolute rates, which refer to the cavity field. The same model gives an intrinsic 4A2→2E^4A_2 \rightarrow^2E rate of 165–562 kHz (lifetime 1.78–6.06 μ\mus) and a green-light recharge of 4A2^4A_2 of 438–1048 kHz/mW [13]; at milliwatt green powers both routes out of the quartet are comparable, in line with the partial relaxation to 2E^2E discussed above. Picosecond pulses at 1064 nm (1.165 eV) quench 3E^3E of single centers in nitrogen-poor diamond into a dark state that returns to 3E^3E or 3A2^3A_2 within nanoseconds; there this was attributed to excitation rather than ionization, because the emission recovers and keeps the NV−^- spectrum [24, 25]. No bound triplet lies within 0.99–1.36 eV above 3E^3E, the lowest higher triplet being 2.385 eV above it [26], so the nature of this state is open. A charge-neutral process of this kind would act on 3E^3E in our range as channel I does, bypassing the intersystem crossing; in the present fits its effect would be absorbed into the effective σI\sigma_I. The charge-resolved data of Ref. [13] show that a 3E^3E channel below the quartet threshold does produce NV0^0.

Inside the fit: charge cycle and the role of the donors. Figure S4 decomposes the steady state of the fit into the channels that carry the charge cycle. For each channel the flux per pulse period is computed from the periodic populations (for the rate equations, from their exact time integral over the period). The fluxes are averaged over the focus and the donor classes as the signals are. Ionization and recharge balance to 10−1310^{-13}. Along the 300 mW scan [Fig. S4(a,b)], two cycles carry the charge:

Charge cycle of the fit of the main text

Figure S4. Charge cycle of the fit of the main text. (a) Shares of the channels that ionize NV−^{-} along the 300 mW scan: two-photon ionization of 3A2{}^{3}A_{2} (A), ionization of 3E{}^{3}E into 2E{}^{2}E (I) and into 4A2{}^{4}A_{2} (Q), and electron transfer from 3E{}^{3}E to nitrogen (ftf_{\mathrm{t}} and ktk_{\mathrm{t}}). (b) Shares of the channels that recharge NV0^{0}: photo-recharge of 2A2{}^{2}A_{2} (R) and of 4A2{}^{4}A_{2} (Rq_{\mathrm{q}}), and tunnelling return from the nearest donor (kdk_{\mathrm{d}}, from 2E{}^{2}E and from 4A2{}^{4}A_{2}). (c) NV0^{0} fraction, time-averaged, along both scans. (d,e) As (a,b) along the 40 mW scan (laser width 12 nm), colors as in (a,b). (f) ODMR contrast of the 40 mW scan relative to 990–1000 nm, measured (S6) and for the fit of the main text (solid), without donor return at the same parameters (dotted), and without donor return refitted (dashed; Table S5). All quantities are averaged over the focus and the donor classes as the signals are.

  • Below about 995 nm, channel Q followed by RqR_q, which changes no charge state on balance but randomizes the spin (S5, Fate of the quartet).

  • Above 1040 nm, channel I followed by the recharge R; channel I then provides 87–95% of the ionization.

Electron transfer to nitrogen (ftf_t and ktk_t) contributes 1–5% of the ionization, and channel A at most 13%, at the shortest wavelengths only. The donor return provides 10–13% of the recharge. All of it comes from the quartet of the centers with a donor within about 34 Å (S4.5): it carries all of the recharge of the fastest class and about a quarter of that of the next one (1075 nm). The NV0^0 fraction stays at 0.05–0.13 [Fig. S4(c)].

The 40 mW scan is different Figure S4,Figure S4). Below about 940 nm channel A provides 96–99% of the ionization and drives about 80% of the centers into NV0^{0}. The optical recharge R is weak at this power, so the donor return carries most of the way back (78–97%). The contrast floor below the edge is therefore set by the competition between channel A and the donor return. The centers without a nearby donor are pumped into NV0^{0}, and those with one keep part of their NV−^{-} population.

Table S5 tests how much each of these ingredients matters. Each is changed with the other parameters of the fit kept (no refit), and then the joint fit of S6 (IP and the strengths free, Eq=1.23E_q = 1.23 eV; three starting points, the best kept, since IP and the strength of channel A trade against each other) is repeated.

ChangeNV0^{0}χL2\chi_L^2χC2\chi_C^2IP (eV)χL2\chi_L^2χC2\chi_C^2χS2\chi_S^2Quartet (eV)
none0.06445.419.82.62845.220.041.00.547
no donor return, kd=0k_d = 0 ([N] ≲1\lesssim1 ppm)0.07546.740.02.57241.017.351.20.603
kd×0.1k_d \times0.10.06645.621.02.60544.822.942.20.570
kd×10k_d \times100.06145.319.32.64045.217.938.90.535
[N] = 100 ppm0.01851.836.82.66350.012.069.70.512
no cutoff of kdk_d (all classes return)0.06445.419.82.63145.219.741.30.544
no fast transfer, ft=0f_t = 00.05946.619.92.62946.220.041.00.546
no slow transfer, kt=0k_t = 00.06345.619.82.63145.519.741.30.544
no spin blockade, qb=1q_b = 10.06445.419.82.63145.219.741.30.544

Table S5. Sensitivity of the fit to the donor and electron-transfer ingredients. Without refit: the fit of the main text with one ingredient changed; NV0^{0} fraction at 1075 nm and 300 mW, and χ2\chi^2 of the 52 contrast-loss values (LL) and of the contrast CC of the 40 mW scan (10 points). Refit: the joint fit of S6 to LL and to CC and SS of the scan (Eq=1.23E_q = 1.23 eV; IP and the strengths free, best of three starting points). Quartet: Eq−IP+ZPLE_q - \mathrm{IP} + \mathrm{ZPL}. The refits of the unchanged fit and of the two changes without effect (no cutoff, no spin blockade) agree within 0.003 eV in IP and 0.1 in the total χ2\chi^2, which indicates the precision of the refit columns.

  • The 52 contrast-loss values hardly depend on the donors. Removing the donor return, changing its rate tenfold in either direction, dropping the cutoff of S4.5, the electron transfer to nitrogen or the spin blockade of the quartet changes LL by at most 0.5%, and χ2\chi^2 of these values by at most 1.3 without refit. The threshold EqE_q, which these values determine, is therefore fixed independently of the donor model.

  • The 40 mW scan depends on the donors. Without any return (the case of [N] ≲1\lesssim1 ppm, where no class exceeds 10310^3 s−1^{-1}), the same parameters leave too little contrast below the edge Figure S4, dotted]. The refit restores it with a much weaker channel A and moves IP to 2.572 eV, at nearly the same total χ2\chi^2 (109 against 106). At a tenth or ten times the calculated rate the refit gives IP = 2.605–2.640 eV.

  • A tenfold higher nitrogen density, 100 ppm, keeps NV0^{0} near 2% and describes the data clearly worse even after the refit (total χ2=132\chi^2 = 132).

For the sample studied ([N] = 10 ppm) the donor return exists, and the variants with return give quartet energies of 0.535–0.570 eV, within 0.54 ± 0.04 eV. The limit without return marks how far IP could move if the donor model were grossly wrong: the data alone do not exclude it (Δχ2=3\Delta\chi^2 = 3). Scanned over EqE_q in this limit, the joint fit keeps the best threshold at Eq=1.23E_q = 1.23 eV and gives IP = 2.57 eV, so that the quartet energy would be 0.60 eV, just above the quoted range.

Ground-state ionization threshold

Data. The scan covers 910–1000 nm in 10 nm steps at 40 mW, with full ODMR spectra and SS read at every point (Table S6). At this power SS is 0.18–0.60 mV above a dark level of 32.5 mV, whose drift over the scan (0.02–0.04 mV) is included in the uncertainty of SS. The 1075 nm reference at the start and the end of the scan gives C=0.89C = 0.89 and 0.85% and D=2869.76D = 2869.76 and 2869.84 MHz.

λ\lambda (nm)9109209309409509609709809901000
2ℏω2\hbar\omega (eV)2.7252.6952.6662.6382.6102.5832.5562.5302.5052.480
C/C990−1000C/C_{990-1000}0.09(6)0.06(6)0.08(5)0.30(9)0.37(6)0.58(4)0.68(5)0.84(3)1.05(4)0.95(6)
S/S980−990S/S_{980-990}0.480.380.330.310.430.480.781.030.970.79

Table S6. 40 mW scan: contrast relative to its mean at 990–1000 nm and photoluminescence relative to its mean at 980–990 nm.

The edge. The contrast falls from its plateau at 980–1000 nm to a floor of 0.06–0.09 below 930 nm; it crosses half of the plateau at 956 nm (2ℏω=2.592\hbar\omega= 2.59 eV). The photoluminescence does not follow: it drops to about one third at 930–940 nm. The remaining light carries no spin information, as expected when the ground state is ionized into NV0^{0}. faster than it is repumped and polarized. Below 930 nm SS rises again, to 0.48 at 910 nm, which the model does not reproduce (0.19 at 910 nm; these points give about half of the χ2\chi^{2} of SS in Table S7). The contrast, which fixes IP, is not affected: the fit to CC alone gives nearly the same IP (2.64 against 2.63 eV). Over the edge the laser spectrum (12 nm) and the inhomogeneous width (20 meV) broaden 2ℏω2\hbar\omega by about ±0.02\pm0.02 eV, and the phonon sideband shifts the rise of channel A above its zero-phonon threshold (S4.2); the edge itself, 940–960 nm, spans 2ℏω=2.582\hbar\omega= 2.58–2.64 eV.

FitIP (eV)Channel A (GM)Deviation of LL (%)χ2\chi^2, CCχ2\chi^2, SS
52 values only, IP held2.600.71.1720461
52 values only, IP held2.661.81.1816731
joint, CC of the scan2.6421.41.1712814
joint, CC and SS of the scan2.631151.392041
joint, CC, and SS at ≥930\geq930 nm only2.652461.391749 (21)
joint, CC and SS, IP held (main text)2.63151.402041
joint, CC and SS, IP held (saturated reading)2.54–1.586853

Table S7. Fits of the 52 contrast-loss values together with the 40 mW scan (10 values each of CC and SS), Eq=1.23E_q = 1.23 eV, r=0.13r = 0.13, sinh=20s_{\mathrm{inh}} = 20 meV: threshold IP, strength of channel A, deviation of the 52 values, and χ2\chi^2 of the scan (of SS at all ten wavelengths; in parentheses, at the eight fitted ones).

Joint fit. The 52 contrast-loss values do not fix IP: refitted with IP held at 2.60, 2.63 and 2.66 eV, they give the same deviation (1.17–1.18% at Eq=1.23E_q = 1.23 eV), while the strength of channel A rises from 0.7 to 1.5 and 1.8 GM; such fits miss the photoluminescence of the 40 mW scan. This scan removes the degeneracy, because its contrast floor and photoluminescence depend on where the threshold lies relative to the edge. We therefore fit both data sets together, with IP free in addition to the five parameters of S5, the conditions of this scan (laser width 12 nm, 0.9 of the set power at the focus), and EqE_q scanned (Table S7). With the contrast and the photoluminescence of the scan, the best threshold is Eq=1.215E_q = 1.215–1.231.23 eV and IP = 2.63–2.66 eV; with the contrast alone, the fit leaves the photoluminescence far off (χ2=814\chi^2 = 814). We take IP⁡(3A2)=2.63±0.03\operatorname{IP}({}^{3}A_2) = 2.63 \pm0.03 eV, which covers these fits, the inhomogeneous widths of S5 and the variants of the donor model (Table S5) and lies within the edge. It agrees with the photocurrent thresholds of NV−^{-} ionization in irradiated type-Ib diamond, 2.66(4) and 2.69(3) eV [4]. Fitting SS only at ≥930\geq930 nm, where the model reproduces it (see The edge), gives IP = 2.65–2.66 eV and a quartet energy of 0.51–0.52 eV at the same Eq=1.23E_q = 1.23 eV, inside the quoted ranges, and a contrast floor of 0.08–0.09 (Table S7). The fit of the main text has IP held at 2.63 eV and includes both CC and SS of this scan at all wavelengths; it leaves a floor of 0.12, slightly above the measured 0.06–0.09.

Saturated reading. The alternative reading places the threshold well below the edge, which then marks the saturation of channel A. With IP held at 2.54 eV the best joint fit leaves a contrast floor of 0.32 below 930 nm, against 0.06–0.09 measured, and describes both data sets worse (Table S7); this reading is excluded.

Channels through the singlets

Figure S5 collects the photoionization and recharge channels of the two charge states and places their thresholds on the laser axis for an illustrative singlet energy E(1E)−E(3A2)=ΔST=0.36E({}^{1}E) - E({}^{3}A_2) = \Delta_{\mathrm{ST}} = 0.36 eV (E(1A1)=E(1E)+1.190E({}^{1}A_1) = E({}^{1}E) + 1.190 eV). The channels through the singlets have thresholds within the range of the data for any ΔST\Delta_{\mathrm{ST}} between 0.30 and 0.42 eV. The 3E{}^{3}E–1A1{}^{1}A_1 gap of 0.334–0.375 eV, inferred from calculated and measured intersystem-crossing rates [27], gives with the 3E{}^{3}E zero-phonon energy of 1.945 eV ΔST=0.38\Delta_{\mathrm{ST}} = 0.38–0.42 eV, at the upper end of this range. The singlet channels were tested with the parameters of the fit of the main text, without refitting (Table S8).

Total-energy diagram and threshold channels for photoionization and recharge

Figure S5. (a) Total-energy diagram with the photoionization (NV−→NV0+eCB−\mathrm{NV}^{-} \rightarrow\mathrm{NV}^{0} + e^{-}_{\mathrm{CB}}) and recharge (NV0→NV−+hVB+\mathrm{NV}^{0} \rightarrow\mathrm{NV}^{-} + h^{+}_{\mathrm{VB}}) channels, numbered; lifetimes of the initial states. (b) Threshold of each channel as a laser wavelength (one or two photons) with its open side; filled symbols, onset seen in the data; open symbols, not seen or not resolved. Gray bars, spans of the scans; vertical lines, the 1E→1A1{}^{1}E \rightarrow{}^{1}A_{1} zero-phonon line and the long-wavelength cut-offs of the two-photon absorption of NV0\mathrm{NV}^{0} and NV−\mathrm{NV}^{-}.

ChannelStrengthModelMeasured
1A1^{1}A_1 ionization: change of L(1042)L(1042) from 150 to 300 mW (%)
full8.6–9.8≤6\le6 (2σ\sigma)
×0.3\times0.35.9–6.6
×0.1\times0.13.8–4.4
×0.03\times0.032.9–3.1
off2.5
full, E(1E)=0.20E(^{1}E) = 0.20 or 0.24 eV (closed)2.5
full, E(1E)=0.27E(^{1}E) = 0.27 eV7.3
full, E(1E)=0.33E(^{1}E) = 0.33 eV8.8
1E^{1}E two-photon ionization: L(1030)−L(1046)L(1030) - L(1046) at 150 / 300 mW (%)
1 GM4.8–5.5 / 10.8–13.86.4 ±\pm 2.0 / 6.9 ±\pm 2.0
3 GM7.2–8.7 / 16.2–20.9
off3.2 / 6.0
Recharge into 1E^{1}E or 1A1^{1}A_1: deviation of the 52 values (%)
free1.15–1.18–
off1.17–

Table S8. Singlet channels, with the parameters of the fit of the main text (Eq=1.23E_q = 1.23 eV), for ΔST=0.30\Delta_{ST} = 0.30, 0.36 and 0.42 eV.

Ionization of 1A1{}^{1}A_1 at the 1E→1A1{}^{1}E \rightarrow{}^{1}A_1 resonance. A center shelved in 1E{}^{1}E absorbs one photon at the 1042 nm resonance: a Lorentzian zero-phonon line of 4 nm width with its phonon sideband [14] and the measured room-temperature peak cross section 4×10−184 \times10^{-18} cm2^2 [14], consistent with the calculated radiative lifetime of 1A1{}^{1}A_1 [15]. Within the same pulse 1A1{}^{1}A_1 can absorb a further photon; under continuous illumination its 100 ps lifetime makes this unlikely [5]. By the one-electron selection rule, ionization of 1A1{}^{1}A_1 reaches only 2E{}^{2}E: removing an ee electron from the a12e2a_1^2e^2 part of 1A1{}^{1}A_1 (about 90%) gives the a12e1a_1^2e^1 part of 2E{}^{2}E (71% [5]), whereas 2A2{}^{2}A_2 (S=3/2S = 3/2) cannot be reached from a singlet and 2A1{}^{2}A_1 lies far above the threshold. We therefore take 0.09 ×\times 0.71 = 0.064 the calculated cross section of 3A2{}^{3}A_2 [2] at the same excess energy, above the threshold IP – ΔST\Delta_{\mathrm{ST}} – 1.190 eV (1.02–1.14 eV, 0.05–0.17 eV below the photon energy). The 3A2{}^{3}A_2 curve is appropriate for 1A1{}^{1}A_1 also because the two states have nearly the same equilibrium geometry: relative to that of 3A2{}^{3}A_2, 1A1{}^{1}A_1 relaxes by only 16 meV, against 256 meV for 3E{}^{3}E [27]. At equal excess energy the final conduction-band states, their density and the one-electron matrix elements are those of the 3A2{}^{3}A_2 calculation, as assumed in Ref. [2] for the ionization of 1E{}^{1}E; the cross section, σ∝ℏω∑j∣rij∣2δ(ℏω−Eij)\sigma\propto\hbar\omega\sum_j |r_{ij}|^2 \delta(\hbar\omega- E_{ij}), then differs only by the photon energy, and we rescale the 3A2{}^{3}A_2 value from its own photon energy, IP plus the excess energy, to ℏω\hbar\omega, a factor 0.43 at the resonance (constant rijr_{ij}; a constant momentum matrix element would invert this factor). This cross section is thus derived, not calculated; its construction is shown step by step in Figure S3. The signature is a contrast loss at 1042 nm that grows with power. Measured, L(1042)=3.2±1.8%L(1042) = 3.2 \pm1.8\% at 150 mW and 4.6 ±\pm 1.4% at 300 mW, a growth of at most 6% [2]; the model without this route gives +2.5%, with it +8.6 to +9.8% (3.1–3.7σ\sigma above the measured growth). The route is close to saturation, so this value hardly depends on the strength: scaled by 0.3 it gives +5.9 to +6.6%, at the bound, by 0.1 +3.8 to +4.4%, by 0.03 +2.9 to +3.1%. The data thus bound the route to about a third of this estimate or less. The route would close only if 1E{}^{1}E lay 0.24 eV or less above 3A2{}^{3}A_2, which places the threshold at or above the photon energy; the measured ionization energies, IP⁡(3A2)−IP⁡(1E)=0.30\operatorname{IP}({}^{3}A_2) - \operatorname{IP}({}^{1}E) = 0.30–0.38 eV (Sec. S6 and Refs. [22, 23]), exclude this, and over 0.27–0.42 eV the route stays open (Table S8).

Two-photon ionization of 1E{}^{1}E. Off resonance, 1E{}^{1}E is ionized by two photons above IP −- ΔST\Delta_{\mathrm{ST}}, 2.27 eV for ΔST=0.36\Delta_{\mathrm{ST}} = 0.36 eV (2ℏω2\hbar\omega at 1092 nm); the tests with ΔST=0.30\Delta_{\mathrm{ST}} = 0.30–0.42 eV cover thresholds of 2.21–2.33 eV (1064–1122 nm). Because the shelf population grows with power, the channel adds a contrast loss that grows faster than linearly with power at short wavelengths. The excess L(1030)−L(1046)L(1030) - L(1046) measured is 6.4 ±\pm 2.0% at 150 mW and 6.9 ±\pm 2.0% at 300 mW; the model gives 3.2 and 6.0% without the channel, 4.8–5.5 and 10.8–13.8% with 1 GM, and 7.2–8.7 and 16.2–20.9% with 3 GM. At 300 mW, 1 GM already exceeds the measurement by 2.0–3.4σ\sigma; the two-photon cross section is therefore below about 1 GM.

Comparison with the one-photon measurements of the 1E{}^{1}E threshold. The ionization energy of 1E{}^{1}E has been measured with one visible photon: 1.91–2.25 eV from the charge-resolved photoluminescence after the singlet is populated by spin control and illuminated with filtered visible pulses [28]; 2.25–2.33 eV for 1.6–300 K from magnetic-field-modulated photoluminescence [22]; and, with the same method, 2.29–2.33 eV for 50–150 K [23]. In the field-modulation experiments continuous visible light excites the center and, at the same photon energy, ionizes 1E{}^{1}E in a single step at any time during its lifetime. A magnetic field mixes the spin sublevels of 3E{}^{3}E and thereby switches the 1E{}^{1}E population on and off, and the change of the NV0\mathrm{NV}^{0} emission between the two settings isolates the ionization of 1E{}^{1}E from all other channels [22, 23]. Three differences remove this signature from the present experiment. (i) Our photons (0.99–1.36 eV) lie below the one-photon threshold, so 1E{}^{1}E is ionized only by two photons absorbed within one pulse, a nonresonant process whose cross section the data bound below about 1 GM. (ii) For the bracket 2.25–2.33 eV, which holds up to room temperature [22], the two-photon channel opens at 1064–1102 nm, around the window where the contrast loss vanishes within the 1.5% uncertainty; just above threshold the cross section rises from zero and is broadened by the laser spectrum and by phonons, and it becomes appreciable only above threshold where it acts together with channel Q and the 1E→1A1{}^{1}E \rightarrow{}^{1}A_{1} resonance. (iii) We detect the spin contrast in the NV−\mathrm{NV}^{-} band, to which the ionization of 1E{}^{1}E contributes only together with channels Q, I and Rq_q and the ionization of 1A1{}^{1}A_{1}; no setting of the present experiment changes the 1E{}^{1}E population alone. The tests above cover two-photon thresholds of 2.20–2.32 eV, which include most of that bracket; the lower values of Ref. [28] would open the channel over the whole range and are not tested separately.

Recharge into the singlets. Recharge of excited NV0(2A2)\mathrm{NV}^{0}({}^{2}A_{2}) can end in 1E{}^{1}E (one photon, threshold ER+ΔSTE_{\mathrm{R}} + \Delta_{\mathrm{ST}}) or 1A1{}^{1}A_{1} (two photons) instead of 3A2{}^{3}A_{2}. Fits of the 52 values with either channel made explicit and its strength free give deviations of 1.15–1.18%, against 1.17% for the same model with both strengths at zero; in most cases the fitted strength goes to zero. The data neither require nor exclude these channels.

Photoluminescence step and optimum

Photoluminescence step. Below 1060 nm SS falls by a factor of 2.7 at every power (Table S9). The step lies between 1045 and 1060 nm and is flat below 1040 nm; it is reproducible and independent of power from 100 to 500 mW. In the rate model a stronger 3E→NV0(4A2)^{3}E \to\mathrm{NV}^{0}(^{4}A_2) channel does not deplete NV−\mathrm{NV}^{-} by this factor, because the quartet is recharged within the same pulse: a ten times larger cross section lowers SS at 1030 nm by only 9% and removes 70% of the spin contrast, whereas the measured contrast loss at 1030 nm is about 10%. We therefore attribute the step to the two-photon absorption spectrum of NV−\mathrm{NV}^{-}.

Power (mW)λref\lambda_{\mathrm{ref}} (nm)S(1030)/S(λref)S(1030)/S(\lambda_{\mathrm{ref}})
10010700.37–0.40
15010700.35–0.37
2001070, 10750.38–0.39
30010700.36–0.37
50010570.34

Table S9. Photoluminescence at 1030 nm relative to that at the reference wavelength λref\lambda_{\mathrm{ref}}.

Optimum against power. Figure S6 shows the shot-noise figure of merit ΔS/S\Delta S/\sqrt{S} against wavelength at 200–500 mW, normalized at 1030 nm. The 300 mW scan resolves the maximum, at 1070 ±\pm 5 nm. The 200 and 500 mW scans end at 1063 and 1057 nm; up to there the figure of merit rises from 1030 nm by 77% and 24%, and at 500 mW it follows the 300 mW scan to within 8%. At 200 mW, 1075 nm exceeds 1030 nm by 46%. At 1075 nm the figure of merit grows as P0.65P^{0.65} over 88–300 mW and as P0.51P^{0.51} over 150–300 mW [Figure S6].

Plots of signal-to-noise relative to wavelength and laser power

Figure S6. (a) ΔS/S\Delta S/\sqrt{S} relative to 1030 nm against wavelength; at 200 mW two scans are shown. Green band, 1060–1075 nm; dotted lines, the 1E→1A1{}^{1}E \to{}^{1}A_1 zero-phonon line and the visible onset of channel Q. (b) ΔS/S\Delta S/\sqrt{S} at 1075 nm against power with power-law fits; square, 500 mW at 1057 nm, the end of its scan.

Code and data

The rate model, the fitting procedure, the parameter set of Table S2, the 52 contrast-loss values and the 40 mW scan of S6 are available as a Python package in the HUN-REN research data repository at doi:10.5158/ARP/T7NV6O (code under the GNU General Public License v3.0, data under CC BY 4.0). All fixed parameters and the literature curves (the NV−^{-} two-photon absorption of Ref. [3], and the photoionization cross sections, spectral functions and spectral densities of Ref. [2]) are read from CSV files, so that the calculation can be repeated for other samples (for example another nitrogen density) or other excitation conditions. For each wavelength and power the model returns

SS, ΔS\Delta S, CC and LL. The package includes the scripts that recompute every model number and model curve of the main text and of this SM, and the model curves of Figure 3(b) and Figure 4(a) of the main text. The package also contains the raw data: the lock-in files of all ODMR records and spectra behind the 52 contrast-loss values, the 1075 nm reference series and the 40 mW scan, with an index that lists the wavelength, power, SS, ΔS\Delta S and CC of every measurement; from this index the reference curves, the 52 values and the scan of S6 are recomputed.

Figure 3. (a) Contrast against photoluminescence: 1075 nm at 88–300 mW (open circles) with the reference fit, and the 300 mW scan colored by wavelength. (b) Contrast loss at equal SS for the 300 mW scan (error bars, 1.5%), with the rate model fitted to all 52 values, without (dashed) and with (solid, Eq=1.23E_q=1.23 eV) the 3E→NV0(4A2)^3E\to\mathrm{NV}^0(^4A_2) channel; σI=0.13σQ\sigma_I=0.13\sigma_Q.

Use of AI tools. The scripts for the numerical solution of the rate model, the fits and the tests, and those for structuring and plotting the data, were written by the AI assistant Claude (Anthropic; models Opus 4.8, 5 and 5.5, Fable 5 and 5.1, used through Claude Code) following the model specified by the authors: levels, channels, assumptions and parameter choices. The authors checked all equations and inspected all fits and figures.

References

  1. [1]V. Verkh...
  2. [2]L. Razinkovas, M. Maciaszek, F. Reinhard, M. W. Doherty, and A. Alkauskas, Phys. Rev. B 104, 235301 (2021).
  3. [3]P. Ji, R. Balili, J. Beaumariage, S. Mukherjee, D. Snoke, and M. V. G. Dutt, Phys. Rev. B 97, 134112 (2018).
  4. [4]E. Bourgeois, E. Londero, K. Buczak, J. Hruby, M. Gulka, Y. Balasubramaniam, G. Wachter, J. Stursa, K. Dobes, F. Aumayr, M. Trupke, A. Gali, and M. Nesladek, Phys. Rev. B 95, 041402(R) (2017).
  5. [5]G. Thiering and Á. Gali, J. Appl. Phys. 136, 084401 (2024).
  6. [6]P. Siyushev, H. Pinto, M. Vörös, A. Gali, F. Jelezko, and J. Wrachtrup, Phys. Rev. Lett. 110, 167402 (2013).
  7. [7]M. T. Luu, A. T. Younesi, and R. Ulbricht, Mater. Quantum Technol. 4, 035201 (2024).
  8. [8]A. Alkauskas, C. G. Van de Walle, L. Razinkovas, and R. Ulbricht, Phys. Rev. Lett. 137, 136401 (2026).
  9. [9]L. Robledo, H. Bernien, T. van der Sar, and R. Hanson, New J. Phys. 13, 025013 (2013).
  10. [10]R. Ulbricht and Z.-H. Loh, Phys. Rev. B 98, 094309 (2018).
  11. [11]V. M. Acosta, A. Jarmola, E. Bauch, and D. Budker, Phys. Rev. B 82, 201202(R) (2010).
  12. [12]M. W. Doherty, N. B. Manson, P. Delaney, F. Jelezko, J. Wrachtrup, and L. C. L. Hollenberg, Phys. Rep. 528, 1 (2013).
  13. [13]P. K. Shandilya, V. K. Kavatamane, S. Flågan, D. P. Lake, D. Sukachev, and P. E. Barclay, arXiv:2411.10638v2 (2026).arxiv.org/abs/2411.10638
  14. [14]P. Kehayias, M. W. Doherty, D. English, R. Fischer, A. Jarmola, K. Jensen, N. Leefer, P. Hemmer, N. B. Manson, and D. Budker, Phys. Rev. B 88, 165202 (2013).
  15. [15]M. Bockstedte, F. Schütz, T. Garratt, V. Ivády, and A. Gali, npj Quantum Mater. 3, 31 (2018).
  16. [16]L. J. Rogers, S. Armstrong, M. J. Sellars, and N. B. Manson, New J. Phys. 10, 103024 (2008).
  17. [17]T.-L. Wee, Y.-K. Tzeng, C.-C. Han, H.-C. Chang, W. Fann, J.-H. Hsu, K.-M. Chen, and Y.-C. Yu, J. Phys. Chem. A 111, 9379 (2007).
  18. [18]S. Felton, A. M. Edmonds, M. E. Newton, P. M. Martineau, D. Fisher, and D. J. Twitchen, Phys. Rev. B 77, 081201(R) (2008).
  19. [19]D. Wirtitsch, G. Wachter, S. Reisenbauer, M. Gulka, V. Ivády, F. Jelezko, Á. Gali, M. Nesladek, and M. Trupke, Phys. Rev. Research 5, 013014 (2023).
  20. [20]N. Aslam, G. Waldherr, P. Neumann, F. Jelezko, and J. Wrachtrup, New J. Phys. 15, 013064 (2013).
  21. [21]A. A. Wood, A. Lozovoi, R. M. Goldblatt, C. A. Meriles, and A. M. Martin, Phys. Rev. B 109, 134106 (2024).
  22. [22]S. M. Blakley, T. T. Mai, S. J. Moxim, J. T. Ryan, A. J. Biacchi, A. R. Hight Walker, and R. D. McMichael, Phys. Rev. B 110, 134109 (2024).
  23. [23]K. V. Ung, C. A. Ronconali, R. L. Walsworth, and S. M. Blakley, Phys. Status Solidi A 223, e202500538 (2026).
  24. [24]Y. Cao, Y. Liu, J. Lin, M. He, X. Yuan, B. Wu, and E. Wu, Appl. Phys. Lett. 126, 144004 (2025).
  25. [25]Y. Cao, J. Lin, M. He, X. Yuan, B. Wu, and E. Wu, Diamond Relat. Mater. 160, 112987 (2025).
  26. [26]M. T. Luu, C. Linderälv, Z. Benedek, Á. Ganyecz, G. Barcza, V. Ivády, and R. Ulbricht, Appl. Phys. Lett. 126, 234001 (2025).
  27. [27]Y. Jin, J. Park, M. M. McMillan, D. D. Ohm, C. Barnes, B. Pingault, C. Egerstrom, B. Huang, M. Govoni, F. J. Heremans, D. D. Awschalom, and G. Galli, Phys. Rev. Lett. 135, 036401 (2025).
  28. [28]S. A. Wolf, I. Meirzada, G. Haim, and N. Bar-Gill, Phys. Rev. Applied 19, 034076 (2023).

Paper details

vlnc:W_czbwe778
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Claude Opus 4.8 (bare), 5, 5.5, Fable 5

View statement
Looking for related papers…
Contents