WorksPhysics and Astronomy
The XMM Cluster Survey: Cross-Calibration of eROSITA and XMM using Dark Energy Survey Y3 Galaxy Clusters
Abstract
We present the cross-calibration of the eROSITA and XMM telescopes, using galaxy clusters detected by redMaPPer from the first three years of Dark Energy Survey observations (DESY3RM). We use the X-ray: Generate and Analyse (XGA) Python module to measure eROSITA properties, and validate our methodology using a deep pointed eROSITA CAL-PV observation of A3158, and a sample of 119 clusters from the expanded HIgh FLux Galaxy Cluster Sample (eeHiFLUGCS). Next, we construct a sample of DESY3RM clusters matched to XMM observations analysed by the XMM Cluster Survey (XCS), and to clusters in the first release of the eROSITA All-Sky Survey (eRASS1). This produced a sample of 114 DESY3RM clusters with both XMM and eROSITA detections. Our resulting X-ray temperatures determined from eROSITA were compared to eRASS1 catalogue values, showing consistency between the two analyses. Comparisons between XMM and eROSITA temperatures reveal a systematic offset, with XMM temperatures 287% higher on average. Finally, we fit - and - scaling relations for both eROSITA and XMM using the same cluster sample, finding minimal differences in the - relation but a clear normalisation offset in the - relation, particularly for the highest richness systems. This study will enable future work combining eROSITA and XMM observatories for DESY3RM clusters.
Introduction
Galaxy clusters are tracers of the most massive dark matter halos in the universe. The mass function of dark matter halos across cosmic time is sensitive to cosmological parameters, hence galaxy cluster properties e.g., the cluster mass, are invaluable for cluster abundance cosmology experiments. Such experiments require well-characterised observables that correlate with cluster mass through scaling relations, with weak gravitational lensing commonly used to calibrate the connection between these mass proxies and the underlying halo mass.
The choice of observable to construct a scaling relation varies between experiments, which span a wide range of wavelengths. Galaxy clusters can be studied via: the hot intracluster medium (ICM), using X-ray and millimetre-wavelength observations, their constituent member galaxies via optical observations, and the underlying dark matter component can be probed by gravitational (weak and strong) lensing. The Dark Energy Survey (DES) is a photometric survey conducted in the , , , and bands covering square degrees of the sky, using the 570 megapixel Dark Energy Camera (DECam, Flaugher et al. 2015). DES uses cluster richness (typically denoted ) as the observable, a probabilistic measure of the number of member galaxies, estimated by the red-sequence Matched-filter Probabilistic Percolation cluster (hereafter redMaPPer, Rykoff et al. 2016) to construct a scaling relation calibrated to masses derived via weak lensing (McClintock et al. 2019).
The cosmological constraints from the first year of DES observations (DES Y1) using cluster abundances and weak lensing (Abbott et al. [2], hereafter A20) were in tension with other DES Y1 analyses and external cosmological experiments. In the - plane, their results were at a tension with DES Y1 3x2pt analysis [1], and tension with the Planck Cosmic Microwave Background results [42]. As A20 discuss, this tension could be due to the slope of the mass-richness relation being biased high due to an incorrect interpretation of the stacked weak lensing signal for low richness () clusters. When these clusters were removed from the analysis, the internal tension with DES Y1 3 × 2pt results is no longer present. Furthermore, A20 uses a stacked weak lensing analysis, thereby losing information of the intrinsic scatter of the scaling relation. Sahlén et al. (2009) demonstrated that the scatter, together with its redshift dependence, needs to be effectively exploited to infer cosmological parameters.
A20 demonstrated the need for multi-wavelength data to better understand systematic effects in their cosmology analysis, primarily via X-ray data from the –Newton2 (hereafter ) and 3 observatories. The X-ray data was used to understand miscentering effects and better describe scaling relations. Zhang et al. (2019) provided a model description of the miscentering of the redMaPPer cluster position compared to the X-ray centroids. redMaPPer richness scaling relations with respect to X-ray luminosity and temperature are investigated in e.g., (Farahi et al. 2019, Hollowood et al. 2019, Giles et al. 2022, Kelly et al. 2024). These studies are all similarly limited by the complex selection function of the and observing strategies, as they are largely driven by follow up of known objects, rather than serendipitous discoveries. Furthermore, studies using contiguous regions are limited by the size of the survey overlap with DES, comprising only deg (Upsdell et al. 2023).
The X-ray telescope (Predehl et al. 2021) on board the Spectrum Roentgen Gamma observatory launched in 2019. With the public release of the first six months of the -All Sky Survey within the western galactic hemisphere (known as eRASS1), 20626.5 deg of X-ray data became available (Merloni et al. 2024). This offers a unique opportunity to support optically selected cosmological samples with X-ray data that has a well-characterised selection function. Aside from DES, forthcoming cluster abundance cosmology analyses from surveys such as Euclid (Euclid Collaboration et al. 2024) and LSST (Ivezić et al. 2019) require an understanding of the systematic effects associated with scaling relations. This work aims to contribute to this effort.
We revisit the X-ray support provided by to DES, by comparing measurements of ICM temperature and luminosity with those measured by . Systematic offsets of physical properties of galaxy clusters derived from different X-ray observatories have been well studied. This has been characterised by comparing and cluster temperatures in e.g., (Nevalainen et al. 2010, Schellenberger et al. 2015). The work of Lopez et al. (2025) performed a cross-calibration with NuSTAR (Harrison et al. 2013), , and . The first cross-calibration (Turner et al. 2022b), hereafter T22, found temperatures larger than . Following the release of eRASS1, Mikgas et al. (2024) studied cross-calibrations, finding a offset with (with a small dependence on cluster temperature). While not focused on cross-calibration, Kelly et al. (2024) found that optical to X-ray scaling relations are affected by the choice of X-ray observatory. It was found that the slope of the richness - X-ray temperature relation differs depending on the use of or for X-ray analysis. It is therefore valuable to characterise this calibration between X-ray instruments to enable future studies to collate data from multiple observatories, and to understand the effect on scaling relations that support cluster abundance cosmology studies.
The work presented herein represents the first application of the X-ray: Generate and Analyse (XGa, Turner et al. 2022a, 2023) software package4 to data. Previously, XGa could only make use of observations (e.g. Turner et al. 2025), but a new release adds support for . We demonstrate the unique capability of XGa to measure X-ray properties of galaxy cluster populations from both and using a consistent methodology. Furthermore, we describe the XGa procedure for deriving higher-level properties, such as entropy and hydrostatic mass profiles, using the example of Abell 3158 (hereafter A3158), which has pointed observations from both and . These results allow us to establish an – cross-calibration applicable to future DES X-ray support studies employing both observatories.
The outline of this paper is as follows; § 2 details the preparation of data from the and archives, ready for XGa ingestion. § 4 introduces the sample of objects that have been detected by redMaPPer, the Cluster Survey (Romer et al. 2001), and . In § 5 we present the updated X-ray: Generate and Analyse (XGa) software package, now including compatibility, and apply it to A3158 as a demonstration of the methodology. We validate the XGa method in § 6, by performing comparisons of X-ray temperatures and luminosities (5 and 6) measured by XGa to the eRASS1 cluster catalogue (Bulbul et al. 2024, hereafter B24), and annular temperatures (7) to clusters in Mikgas et al. (2024), hereafter M24, which were selected from the expanded High Flux Galaxy Cluster Sample (eeHIFLUGCS). In § 7 we provide a , , and 8 calibration of to for the DES subsample described in § 4. We also provide a comparison of optical - X-ray scaling relations as measured by and in § 8. Finally we discuss origins of offsets between observatories in § 9 and provide our conclusions in § 10. For all XGa analysis we assume a cosmology of , , and km s Mpc.
Data
In all subsequent analyses, we employ the open-source Python package XGa. Before XGa can be used, it requires a set of science-ready event lists and, optionally, region files describing the spatial extent of detected sources. Sections 2.1 and 2.2 describe the data from the survey and the calibration and performance verification phases respectively, and their corresponding source regions, which are input into XGa. Section 2.3 details the preparation of the data, making use of the open-source Python package DAXA (Turner et al. 2024). Section 2.4 details the equivalent data products for . Finally, Section 2.5 describes the optical data and cluster detection from DES.
eRASS1
We make use of the public eRASS1 data9, a contiguous area covering the entire western galactic hemisphere, observed from December 2019 to June 2020. The observing strategy of eRASS1 is a constant slew around a series of great circles converging at the ecliptic poles. The result is an average exposure time of s at the ecliptic equator to s at the ecliptic poles (see Merloni et al. (2024), for full details, and in particular Figure 3). The slewing of the telescope means that source photons arrive at the detector across different positions in the field of view, such that sources will be subject to the spatially varying effective area. Consequently, calculations requiring the effective area of the telescope, such as exposure maps and ancillary response files for spectral calibration, must be done in time steps corresponding to the speed of sources across pixels on the detector. This impacts our choices for spectral analysis which are discussed further in § 5.3.

Figure 3. X-ray count rate maps in the 0.5 - 2.0 keV band of A3158 made with eROSITA (Left) and XMM (Right). The annular regions used to generate radial profiles (see Figure 5) are shown with solid white lines. The outer, background subtraction, annulus, is shown with dashed lines.
All eRASS1 data processing was done with the eROSITA Science Analysis Software System for Data Release 1 (hereafter eSASS; Brunner et al. (2022))10.
eRASS1 Source Regions
Throughout this work, we default to using XMM regions (described in § 3.3) to mask contaminating sources from our analysis. In the cases where XMM data is unavailable (see § 5.1), the following procedure is used. For the detection and masking of contaminating sources within eRASS1 data, we use the EXT parameter within the eRASS1 primary source catalogue (Merloni et al. (2024)). EXT represents the core size (in arcseconds) of a beta model fitted to each source detected in the Merloni et al. (2024) pipeline. Using this parameter, we assume that the full spatial extent of each source corresponds to a circular region with a radius given by the ‘Masking Radii’ Column of Table 1.
| Condition | Masking Radii | Notes |
| EXT > 0 | Assuming every extended source is a cluster. corresponds to . | |
| EXT = 0 | 30″ | Point source masking set to FoV-averaged resolution. |
Table 1. Spatial extent of sources in eRASS1 data, used to mask contaminating sources within analysis regions. The ‘Condition’ column lists the criteria for masking a source, with the corresponding ‘Masking Radii’ (next column) specifying the circle radius applied. EXT refers to the EXT column in Merloni et al. (2024) (in arcseconds).
eROSITA CAL-PV
In this work we make use of the calibration and performance verification phase of eROSITA (eROSITA CAL-PV11). This phase took place between September and December 2019, carrying out pointed observations as well as scan observations, including the eROSITA Final Equatorial Depth Survey (eFEDS, Brunner et al. (2022)). We use the pointed observation of galaxy cluster A3158, with observation ID 700177. Figure 1 shows the 0.5 - 2.0 keV image of this observation, using the full eROSITA field of view (0.515° radius), with the centre of A3158 (R.A., Dec.) = (55.71°, -53.63°) indicated by a white crosshair. The central coordinates and redshift () of A3158 are taken from Whelan et al. (2022), hereafter W22). Since this observation has an exposure time of seconds, it enables high enough signal to noise to provide constraints on analysis products up to the level of hydrostatic mass profiles. Data processing of this observation was done with the early data release version of eSASS12.

Figure 1. The eROSITA CAL-PV observation (observation ID 700177) of galaxy cluster A3158 at . The image shows the full eROSITA field of view (0.515° radius), with white cross hairs indicating the A3158 centre of (R.A., Dec.) = (55.71°, -53.63°) (taken from W22), from which annular spectra are generated. The manually selected contaminating regions, created using the Xga interactive region editor tool, are indicated by the red ellipses, and are excluded from all analysis. The contaminating regions for XMM are shown in the right panel of Figure A1.
eROSITA CAL-PV Source Regions
For the observation of A3158, identification of contaminating sources was done manually via the inbuilt Xga region editor described in Turner et al. (2025). This differs from the method described in Table 1 as there were no point source catalogues available for this observation. The manually identified contaminating sources are excluded from subsequent analysis, and are shown by red ellipse regions in Figure 1. These masks can be found in the accompanying GitHub repository for this study13.
Acquiring and Processing eROSITA Data with Daxa
The open-source Python module Democratising Archival X-ray Astronomy14 (hereafter Daxa; Turner et al. (2024)) facilitates the full ex-
ploitation of archival data from X-ray missions including eROSITA, XMM, Chandra, Swift (Gehrels et al. 2004), NuSTAR (Harrison et al. 2013), and XRISM [69]. Daxa allows users to interact with data archives of various X-ray telescopes in a consistent manner through Python; acquire said archives; conduct the cleaning and pre-processing steps; and update those archives with new observations.
We obtain eROSITA data using Daxa, and employ the builtin Daxa function, full_process_erosita, for processing. This function internally calls the eSASS FLAREGTI command, with parameters set to the recommended defaults. FLAREGTI appends Good Time Intervals (GTIs) to the unprocessed event lists, excluding time periods affected by soft-proton flaring. These GTIs are then applied using the eSASS command EVTOOL, which retains only valid single-, double-, triple-, and quadruple-pixel events, while removing those flagged as corrupt or belonging to corrupt frames.
XMM-Newton
For XMM analysis we use public data from the XMM Science Archive15, pre-processed according to the XMM Cluster Survey (XCS; Romer et al. 2001) pipeline as described in Lloyd-Davies et al. (2011) and Giles et al. (2022), yielding event lists cleaned of time periods with a high background. For XMM contaminating source detection and masking we use the XCS Automated Pipeline Algorithm (Xapa), based on WAVDETECT (Freeman et al. 2002). WAVDETECT is described in § 4.1 of Lloyd-Davies et al. (2011). For all XMM product generation, the XMM Science Analysis Software (SAS) version 22.1.0 was used.
DES Y3 RedMaPPer Cluster Catalogue
In this work we make use of galaxy clusters identified by redMaPPer applied to the first three years of Dark Energy Survey observations (hereafter DESY3). The DESY3 redMaPPer catalogue used in this work is presented in Abbott et al. [3]. We use the volume-limited, publicly available catalogue16, containing 21,092 galaxy clusters between redshifts of and a richness range spanning . The redMaPPer algorithm self-trains the red sequence model to available spectroscopic redshifts and iteratively estimates photometric redshifts for each detected cluster. A calculation of cluster richness (hereafter ) is performed, which is defined as the sum of membership probabilities of all galaxies within a scale radius, , defined by . Additional information about redMaPPer and examples of its scientific applications can be found in: Rykoff et al. (2014); Rozo & Rykoff (2014); Rozo et al. (2015a,b); Simet et al. (2017); McClintock et al. (2019); Giles et al. (2022).
Samples of Galaxy Clusters
In this section we describe the galaxy cluster samples analysed in this work. To demonstrate the full suite of XGA analysis tools for galaxy clusters, we use the eROSITA CAL-PV observation of A3158. In the proceeding § 5, we apply the XGA methodology to larger samples to validate the method and perform cross-calibrations. The remainder of this section describes those galaxy cluster samples.
Validation Samples
The following galaxy cluster samples are used for validating the XGA method of measuring the X-ray temperature and luminosity from eROSITA observations.
The first sample is drawn from Mígkas et al. (2024), hereafter M24) and is publicly available from a GitHub repository17. This sample is a subsample of the expanded HIgh FLux Galaxy Cluster Sample (eeHIFLUGCS) as detailed in Mígkas et al. (2020). Briefly, cluster detections from the Meta-Catalogue of X-ray detected Clusters of Galaxies (Piffaretti et al. 2011) were selected based on a threshold of an unabsorbed 0.1-2.4 keV X-ray flux of ergs s cm. The M24 sample comprises 152 clusters in total. For this work, we focus on the subset of M24 with a measured temperature within an annular radius of (hereafter ) from eROSITA, yielding the 119 clusters used in § 6.
The second sample is taken from the eRASS1 cluster catalogue presented in Bulbul et al. (2024), hereafter B24). In brief, these clusters were detected in the eRASS1 data in the 0.2-2.3 keV band using the source detection pipeline in Merloni et al. (2024). B24 applies a selection of EXT greater than 0″ and an extent likelihood () greater than 3, followed by a cleaning procedure to remove regions of bright Galactic emission and cases where a single extended source was artificially segmented into multiple detections. An optical confirmation and redshift allocation process was then carried out, as described in Kluge et al. (2024), resulting in a final catalogue of 12,247 galaxy groups and clusters.
DES-XCS-eRO
In this work we apply XGA to a subsample of the 12,247 B24 clusters (§ 4.1) that are also matched to DES Y3 redMaPPer catalogue entries covered by XMM observations. First, DESY3 redMaPPer clusters within the eRASS1 footprint were identified. For a representation of the full overlap of DES with the eRASS1, see Figure 12 in Upsdell et al. (2023). Next these DESY3 redMaPPer clusters were matched to XMM observations via a coordinate search. If a given DESY3 redMaPPer cluster centroid position fell within 15′ of the aimpoint of one or more XMM observations, then that cluster was flagged as having an XMM match. A visual inspection of eRASS1 images, DES cutouts, and XMM images was conducted to ensure that the same source was being detected across all three telescopes. For this visualisation, we used the OCTAVIUS (Object Classification Tools for Astronomy VIsualiSation) platform18, a dynamic and interactive web interface for visualising astronomy images with the functionality of classification. We ensured redshift consistency between B24 and the DES Y3 redMaPPer catalogue, in order to remove false matches due to projection effects. One such case was identified, in which the B24 cluster 1eRASS J032951.5−523451 (with ) was preliminary associated with a redMaPPer system mem_match_id = 43189 (with ). Visual inspection of the galaxies in the DES cutout revealed a foreground and background cluster projected in close proximity, indicating that this was not a genuine physical association. This system was therefore removed from the sample, resulting in a final sample of 114 clusters (we refer to this sample hereafter as the DES-XCS-eRO sample). None of the clusters selected had a value , where is the probability of the source being a contaminant, as defined by B24.

Figure 12. Trend in the eROSITA–XMM offset as a function of the lower count threshold applied to the cluster sample. The offset is defined as the difference between the XMM and eROSITA measurement, divided by the eROSITA measurement, given as a percentage. The offset fitted with a fixed slope is shown in pink, while the offset for a cluster with keV measured by eROSITA with a varying slope is shown in blue.
We compare the redshift distributions of previous samples used for and galaxy cluster cross-calibration in Figure 2. The sample used in this work spans a wider redshift range than that of M24, and is comparable to the sample of T22, though it contains a larger number of clusters.

Figure 2. Redshift distribution of the DES-XCS-eRO sample (blue) used in this work for cross-calibration between and (see § 4.2), compared with previous cross-calibration samples: the M24 sample (pink) and the T22 sample (yellow).
Methodology
Here we present the cluster analysis methodology using Xga. Xga is an open-source Python module, listed on the Astrophysics Source Code Library (ASCL; Turner et al. 2023), that facilitates X-ray astronomy through data product generation from cleaned event lists and subsequent analysis of those products. It allows the user to interact with and analyse X-ray data consistently within a Python environment, promoting reproducible and transparent science. Previous versions of Xga exclusively facilitated analysis. Henceforth, we have developed Xga for compatibility with the telescope, to normalise the interface of X-ray analysis across multiple instruments and make archival data exploration accessible and reproducible. In the following subsections we introduce analysis within Xga and demonstrate the full suite of galaxy cluster analysis available. We also include the equivalent analysis with , demonstrating the capability of Xga to carry out analysis with two telescopes through a consistent interface. In this section we only detail the Xga methodology because the Xga methodology for was presented in Turner et al. (2025, hereafter T25).
Setting up Xga
To ingest galaxy clusters into Xga, the coordinates, redshift, and annular radius (e.g., an overdensity radius such as ) must be provided. For A3158 we use (R.A., Dec.) = (, ), , and kpc. For the M24 validation sample, we use the values available in M24 for the central coordinates, redshifts, and values. For the DES-XCS-eRO sample, we adopt the central coordinates derived by Xapa (described in § 3.3), and the redshift and calculated in B24.
Once this initial information is provided, Xga searches for relevant observations within whatever prepared data sets have been provided (see § 3.2 & § 3.3). For eRASS1, where the survey is divided into tiles, we adopt a search radius of around each cluster’s central coordinate to ensure that clusters near the boundaries include all relevant events. For observations, we search within radius.
Optionally, the user may provide region files to Xga, enabling the automated masking of contaminating sources. In this work, we supply such files, and the automated masking is utilised for all analysis (see § 3.0.1, § 3.1.1, and § 3.3). Where data is available, we provide Xapa-identified regions to Xga, which are applied to both the and analyses. In cases where no data is available, for example some measured clusters in M24, and at larger radii that extend beyond the field of view, we default to using source regions described by Table 1. Xga cross-matches the regions defined in these files with the user-specified analysis coordinates, identifying the nearest extended source as the galaxy cluster region. All other regions are treated as contaminants, and their spatial extent is masked from subsequent Xga analysis.
Generating Images and Exposure Maps
In this section we focus on the methodology of generating images and exposure maps with Xga.
To account for clusters that span multiple tiles of eRASS1, Xga merges relevant event lists using the eSASS EVTOOL command, producing a combined event list from which subsequent data products are generated. For image generation Xga again calls EVTOOL, generating images in the - keV band. Each image pixel is set to be , matching the pixel size adopted by Xapa for images (i.e. the default pixel size used by XCS, Lloyd-Davies et al. (2011), § 3.3). Exposure maps are produced using the EXPMAP command with parameters withweights=yes, to weight each of the seven telescope modules by their relative contributions to the effective area, and withdetmaps=yes, to exclude exposure contributions from the edges of the detector where the effective area is challenging to characterise reliably. Once images and exposure maps of equivalent energy bands have been generated, Xga automatically computes a ratemap.
Generating and Fitting Spectra
Spectral extraction for is performed on a merged event list, which is the combination of all Xga-identified relevant observations (as described in § 5.2). Xga interfaces with the eSASS command SRCTOOL to generate spectra. Due to the eRASS1 observing strategy described in § 3, for spectral calibration, the effective area that a source extraction region is subject to varies across time. Since the clusters used in this work have large spatial extents with mixed morphologies, we provide SRCTOOL with the image generated in § 5.2 to the extmap argument, and set psf type=NONE. This allows SRCTOOL to generate an ancillary response file that is customised to the source’s movement across the telescope’s field of view. We increase the tstep argument from the default to , as a compromise between processing time and spectral calibration accuracy. Lastly we use the HEASoft19 ftgrouppha command to group the output spectrum by a minimum count of , in order to improve the signal to noise of each point on the spectrum. In this work we generate a combined spectrum for all seven telescope modules.
For the treatment of the background, XGA uses a local annulus to extract a background spectrum, which is then subtracted from the source spectrum after a scaling proportional to the source extraction area is applied. We note that in cases such as the right panel of Figure 3, where the background region extends beyond the instrument field of view, only the area intersecting the detector is used to calculate this scaling.
Due to the clusters covering a large area in the sky, the background annulus spectrum is generated in a separate SRCTOOL command run, so that the GTIs from the source region spectra are not used on the background one thereby increasing the signal to noise in the background spectrum. We select the local area for the background by using an annulus centred on the cluster centre with an inner radii of , and the outer radii of .
In this work we perform several temperature () and luminosity () measurements. Throughout, spectra are fit within XGA using version 12.14.1 of Xspec (Arnaud 1996). Spectra are fit with an absorbed plasma emission model (constant×tbabs×apec; Wilms et al. 2000; Smith et al. 2001). Several parameters are frozen during fitting: the nH value required by tbabs is set using the HEASoft nh command, with the column density taken from HI4PI Collaboration et al. (2016); the metal abundance is fixed at ; and the redshift is frozen at the respective catalogue value. All fits are performed using the -statistic (Cash 1979) over the 0.3 - 7.9 keV range, and with the abundance table of Asplund et al. (2009).
The fitting method described above is used by XGA for spectra extracted from cluster-wide, core excluded, and annular regions. For the cluster-wide (or “global”) spectra, a circular region centred on input centroid was used. The radius of this region can be set in XGA. For example was used in Sections 5.2 and § 7. For core excluded spectra, a single circular annulus was used. The inner and outer radii can be set in XGA. For example was used in Section 5.1. For annular spectra, the regions were selected as described below (§ 5.4.1).
Analysis of Radial Profiles
In the following section we provide summaries of the XGA methodology to generate profiles of: temperature, gas density, hydrostatic mass and entropy. For a comprehensive description see T25 (and specifically § 2 of that paper). We note that in the latest version of XGA, functionality has been added to measure entropy profiles, which is described in full in § 5.7.
Calculating Annuli Widths for Spectral Analysis
For all profiles requiring spectral analysis, a series of concentric circular annuli centred on the central coordinates are constructed. See Figure 3 for the visualisation of the annuli used during the analysis of A3158 and Figure 4 for examples of fitted annular spectra. The choices of radii for the annuli were the following:
Figure 4. Example Xga generated A3158 spectra from eROSITA (Left) and XMM (Right). The spectra were extracted from the 0.20 - 0.26 annulus. The Xga fitting to a model with metallicity () and Hydrogen column density () frozen is shown with the orange line and residuals. Also with frozen and free (blue line/residuals). For the purposes of this illustration, a minimum count (or “grouping”) of 100 was used (for the rest of the analysis in this paper, 5 was used). Left: eROSITA combined spectrum from all seven telescope modules. Right: XMM spectrum from the PN instrument.
The outermost radius of the last annuli is set to 1,200 kpc for eROSITA, and 700 kpc for XMM.
The minimum width of an annulus () is set to 50″ so that individual spectra have enough signal to produce a reliable fit, and to encompass an area larger than the point spread functions of both telescopes.
We impose a minimum of 1,000 background subtracted counts in each annulus, where the counts are determined from an image generated in the energy band of 0.5 keV to 2.0 keV.
The outermost radius, , is adjusted outwardly, such that an integer number of are encompassed, preserving the minimum annulus width requirement.
Background subtracted counts within bins of width () are then calculated. The width of bins is then increased until the minimum count is reached. (The profile fitting does not proceed if three or fewer annular bins are defined.)
Projected Temperature Profiles
XGA supports the measurement of projected temperature profiles, as well as the deprojection of those measurements to infer the underlying 3D temperature profiles. For projected temperature profiles, the annuli for spectral extraction are determined via the method described in § 5.4.1. For each annulus, spectra are extracted and fitted as described in § 5.3, thereby obtaining a measurement of temperature. Figure 5 shows an XGA measured temperature profile for A3158 using both eROSITA and XMM data.

Figure 5. Projected temperature profile of A3158 measured with XGA for XMM (pink) and eROSITA (blue). Spectra were extracted from the annular bins shown in Figure 3.
Figure 5 demonstrates that, because of its larger field of view, eROSITA can trace the A3158 projected temperature profiles out to larger radii than XMM. It also shows that there is a systematic offset between the profiles at all radii. This was to be expected: other authors, including using independent (of XGA) techniques, have reported offsets between projected values measured by the two telescopes (T22; M24). However, the direction of the offset (i.e. that eROSITA is reporting higher values than XMM) is unusual, since previous analyses (and that presented below § 7) have found the opposite trend. To ascertain whether this behaviour is intrinsic to A3158, or an artefact of the XGA processing, we have compared our analysis to that of W22.
W22 performed a comparison of eROSITA to XMM projected temperature profiles using the same eROSITA CAL-PV observation of A3158 shown in Figure 3 (left). Figure 6 shows their results (eROSITA given by the purple points and XMM by the orange points) and demonstrates that they found a systematic offset the same direction as that seen in Figure 5. Also shown in Figure 6 are the results of a second XGA analysis of A3158 where the XGA settings have been modified to more closely follow that of W22: we matched their annular bin widths, we allowed the metallicity to vary during the fitting, we set the hydrogen column density to the value they used (), we set the same minimum counts (25) per channel when binning spectra, and we used the 0.8 - 9.0 keV range for spectral fitting. Our results are shown in pink (XMM) and blue (eROSITA), and it can be seen that in the inner (radius< 450 kpc) bins, the XGA and W22 measurements are in close (within 1) agreement. However, at larger radii, some of the XGA measurements differ significantly from those in W22.

Figure 6. A projected temperature profile of A3158. Similar to Figure 5, but with the XGA annuli adjusted to replicate those used by W22. The XGA fitting methodology has also been modified to match W22. The XGA results are shown in pink (XMM) and blue (eROSITA), the values published in W22 are shown in orange (XMM) and purple (eROSITA).
These discrepancies are likely due to the fact that we were not able to exactly replicate the W22 approach, e.g. XGA uses infield, rather than modelled, background subtraction, and our masking decisions (Figure 1) differ. Moreover, W22 extend to 0.5 keV for the cameras with an on-chip filter, and fit each instrument separately (by comparison XGA fits a single combined spectrum). The offsets are most prominent at radii of 600 - 900 kpc. This coincides with a reported region of cool gas (see Figure 14 of W22). Therefore, we have applied an additional mask to test the impact of this posited cool gas, finding the XGA results to be in better agreement with W22 as a result. The new mask and the derived projected temperature profile are shown in Appendix A.
Figure 14. Comparison of the 73 and 74 XGA measured and values for the DES-XCS-eRO sample using eROSITA and XMM for the left and right panels respectively. For the fit with a varying slope: the blue line is the best fit line, the cyan band around it represents the error on the line, and the light blue shaded region represents the scatter. For the fit with a fixed slope: the dark purple line is the best fit line, the purple band around it represents the error on the line, and the light purple shaded region represents the scatter. The red dashed line represents the 1:1 relation.
De-projected Temperature Profiles
The temperature profile is de-projected via the ‘onion-peeling’ method described in Ettori et al. (2002) and Ghirardini et al. (2018). In brief, intersections of 3D shells with projected 2D annuli are calculated using matrix calculations detailed in Appendix A of McLaughlin (1999). This provides a weighting matrix, , that quantifies the contribution of each annulus to a given 3D shell. By combining these weightings with observed profiles of temperature and normalisation of the APEC model (obtained from the spectral fits), their intrinsic 3D distribution can be derived. Uncertainties are obtained by generating 10,000 instances of the projected profiles, thereby calculating 10,000 instances of the 3D profiles. 90% confidence limits can therefore be obtained at each radial point.
The upper left panel of Figure 7 shows the resulting deprojected temperature profile for A3158. A systematic offset between the profiles is again seen at all radii. The values are well constrained for both XMM and eROSITA in the inner regions of the cluster, but become uncertain beyond ~600 kpc. This may be due to the existence of multiphase gas at large radii (see above), whereas Xga uses a single-temperature model.
Figure 7. XMM (pink) and eROSITA (blue) profile measurements of A3158. Upper left: De-projected temperature profile. Upper right: Gas density profile. Estimated from calculations on , which is obtained from spectral fits. Shaded regions in the upper panels represent model fits to the data. Lower left: Hydrostatic mass profile. Lower right: Entropy profile. Shaded regions in the lower panels represent models derived from the model fits in the upper panels.
Density Profiles
To measure the gas density, we use the normalisation parameter of the APEC model, , represented by,
where is the angular diameter distance, is the redshift, and and are the electron and proton number densities.
is obtained from the fits of constant×tbabs×apec to the annular spectra described in § 5.4.1. It is then deprojected from a projected annulus measurement to an inferred 3D spherical shell value, , using the “onion peeling” technique (described in § 5.4.2). Equation (1) is then re-arranged to give the gas density, assuming an electron-to-proton ratio, , using the abundance table of Asplund et al. (2009):
We note this method differs slightly from that described in Section 2.8 of T25, which uses surface brightness to infer gas density, but both methods are available in XGA. In this case we adopt the spectral method because of the high signal-to-noise of the observations.
The resulting gas density profile measured by XGA for A3158 is shown in the upper right panel of Figure 7. The profiles are in close agreement, with eROSITA demonstrating that density continues to drop in the cluster outskirts. It is not unexpected that the density profiles are in agreement despite the systematic offset in the temperature profiles: values depend on the spectral shape, whereas the density is only dependent on the spectral normalisation. A joint Chandra–XMM analysis of 50 clusters by Martino et al. (2014) also reported closely matching density profiles, despite offsets in the profiles.
Hydrostatic Mass Profiles
Under the assumption of spherical symmetry and hydrostatic equilibrium, a hydrostatic mass measurement can be obtained through X-ray observations. This can be expressed as follows,
where is the hydrostatic mass at a radius , is the Boltzmann constant, is the mean molecular weight, is the atomic mass unit, is the gravitational constant, is the gas density profile, and is the deprojected temperature profile. An example of the full derivation of this equation can be found in Fabricant et al. (1980).
Hydrostatic masses are obtained within XGA using the models fitted to gas density and de-projected temperature profiles, as measured in § 5.5 and 4.4.3 respectively. The models fitted to these measurements (as described in Appendix A of T25) have analytical solutions, thereby allowing a direct measurement of their first derivatives at a given radius ( and in Equation (3)). For A3158 we present hydrostatic mass measurements in the lower left panel of Figure 7. The profiles are in close agreement, with eROSITA demonstrating that the enclosed mass continues to rise in the cluster outskirts. As Equation (3) can be reduced to a pressure gradient, the close agreement between the two observatories is likely attributable to the relatively flat deprojected temperature profile (top left panel of Figure 7). The small instrumental offset in temperature is compensated by the combined shapes of the density (top right panel of Figure 7) and temperature profiles, yielding a comparable pressure gradient, and therefore a consistent hydrostatic mass profile. This cross-instrument consistency is, like the density profiles, consistent with the findings of Martino et al. (2014).
Entropy Profiles
The specific entropy profiles of clusters provide insight into the heating and cooling processes of the hot ICM, as well as acting as a reliable observational diagnostic of whether a cluster is undergoing a merger, or has a prominent cool-core (Cavagnolo et al. 2009; Donahue et al. 2026).
Since T25, XGA has been updated to include functionality to measure galaxy cluster entropy profiles, which can be obtained using either a data-driven or model-driven approach. In this work, we present the first use of XGA for entropy measurements, and adopt the model-driven method, described in detail below.
To derive entropy, we make use of the temperature and gas density profiles measured in § 5.4.2 and 4.4.4 respectively. We fit a simplified Vikhlinin temperature model (Vikhlinin et al. 2006) as used by Ghirardini et al. (2019) to the de-projected temperature measurements, and a King model to the gas density measurements; for each, see Appendix A of T25 for a full description of the models and fitting procedure. At a given radius, the corresponding three-dimensional temperature and density are obtained from the fitted models in the form of posterior distributions generated from the 10,000 realisations of the profiles. Each realisation is generated using randomly drawn values from the fitted parameter posterior distributions. Entropy is then calculated as:
where , and are the entropy, de-projected temperature and gas density respectively, at radius . The median value of the resulting entropy distribution is adopted as the best estimate, and the uncertainty is defined by the 68.2% confidence interval.
We present the entropy profile of A3158 in the lower right panel of Figure 7. The general shape of the profile (low in the centre and increasing towards the outskirts) is consistent with previous measurements of cluster thermodynamic profiles, e.g. Cavagnolo et al. (2009); Pratt et al. (2010); Ghirardini et al. (2019); Riva et al. (2024). A systematic offset between eROSITA and XMM is evident. This is driven by the corresponding offset in the de-projected temperature profile (upper left of Figure 7), see Equation (4).
Summary of A3158 Profile Analysis
In summary, through comparisons with the Xga analysis of the XMM observation of A3158, and with the independent analysis of the same data by W22, we conclude that the Xga methodology outlined in § 5.3 is reliable when applied to annular spectral analysis of high signal to noise eROSITA observations made in pointed mode.
Further Validation Tests
In this section we validate the methodology outlined in § 5.3 when applied to cluster-wide and core excluded analyses of eROSITA19 observations made in survey mode. For this we have compared Xga-derived measurements to values reported in the literature. We use two samples of clusters for validation, as described in § 4.1 and § 4.2, and compare Xga measurements of cluster-wide temperatures (), core excluded temperatures (), and soft band (0.5 -2 keV) luminosities ().
All our comparisons to the literature are fitted with a power law of the form:
where is the normalisation, is the slope, is the scatter, and and are the normalisation constants for and respectively. All fits to Equation (5) (and Equation (6) in Section 7) were performed using the LIRA (Linear Regression in Astronomy; Sereno (2016a)) package, which is described in detail in Sereno (2016b).
For all Xga , , and measurements presented in this section (and in § 7 and § 8, including for ), the following quality criteria are applied for a measurement to be deemed successful:
Measurement errors () lie in the range .
keV
ergs cm
The results of the comparisons to the literature are summarised in Table 2.
| Comparison | Normalisation | Scatter | Sample Size |
| 68 | |||
| 30 | |||
| 76 |
Table 2. Best-fit parameters from the comparison of Xga measurements with values from literature. The ‘Comparison’ column lists the literature dataset and property used for comparison. Normalisation and Scatter correspond to and respectively in Equation (5), with the slope fixed at 1, and the values of and set to 1. The ‘Sample Size’ column indicates the number of clusters used for the respective comparison.
Comparison to Migkas2024
Using Xga we have re-analysed the 119 clusters presented in M24 that had measurements. While the M24 and Xga methodologies are not identical, the approaches have some differences, summarised in Table 3, and share several similarities which are detailed below:
| Method | M24 | XGA |
| Accounting for the background | Background modelling of a background region of annulus with an inner radii of , with the outer radii set so that the background area is at least 4 times that of the source region. Fitted simultaneously including components from the Local Hot Bubble, absorbed Milky Way Halo, the cosmic X-ray Background, and the instrumental background | Background subtraction, using an in-field background spectra from a local annulus of – around the analysis region is subtracted from the analysis spectra after the appropriate scaling has taken place |
| Masking | Custom eROSITA source detection, which is based upon Merloni et al. (2024) with additional visual inspection | Masks generated by XAPA for XMM observations. In the case where the local background region extends beyond the XMM field of view, or no XMM data is available, we default to using masks based on sources detected in Merloni et al. (2024), described fully in Table 1 |
| Spectral Fitting Bandwidth | – keV | – keV |
| Metallicity Parameter | Frozen to the value obtained in Migkas et al. (2020) | Frozen to |
| Frozen to the value obtained in Migkas et al. (2020) | Frozen to the value obtained from the HEASoft nh command, taken from HI4PI Collaboration et al. (2016) | |
| XSPEC version | 12.12.0 | 12.14.1 |
Table 3. Differences in the methodology for measuring between Xga and M24.
Spectra are extracted from a 0.2-0.5 annuli centred on the same positions (provided by M24).
Analysis uses the combined spectra from all seven telescope modules on board eROSITA.
A constant×tbabs×apec model is fit to source spectra.
The Asplund et al. (2009) Solar abundance table is used.
C-statistics (Cash (1979)) as the goodness of fit estimator.
As outlined in § 4.1, M24 measures for 119 galaxy clusters with eROSITA. Using the Xga methodology as described in § 5.3 and the quality cuts detailed at the beginning of this Section, we estimate for 68 of the 119 clusters from M24. Figure 8 shows both studies are in close agreement, and a fit to the data (assuming Equation (5) with fixed slope of ) yields (represented by the cyan line and shaded region in Figure 8), which is consistent with a 1:1 relation. When the slope is left as a free parameter, the best fit value is .

Figure 8. The Xga measured versus those measured by M24 using the eROSITA telescope. The best-fit to the relation is given by the blue line, the cyan band around it represents the error on the line, and the red dashed line represents the 1:1 relation. The grey shaded regions from darkest to lightest represent the , and intrinsic scatter.
With regard to the 51 (of 119) M24 clusters not included in the fit, most have Xga errors larger than our limit: 41 have errors in the range. The errors quoted by M24 on their 119 measurements range from 0.02 to 1.51. To remain in the 10 (of 51) either did not return a value within the Xga allowed range of keV or had a error greater than .
Comparison to Bulbul2024
Using Xga we perform spectral fits up to to measure and for all 114 clusters in the DES-XCS-eRO sample (fully described in § 4.2). The methods for X-ray analysis in Xga and B24 differ significantly. In B24, measurements are performed using the MultiBand Projector in 2D (MBProj2D, Sanders et al. (2018)) code. MBProj2D simultaneously fits several X-ray images across multiple energy bands from the data to forward model generated X-ray images to obtain various parameter measurements and profiles, such as and hydrostatic mass (among others). For the analysis in B24, images and exposure maps of size in energy bands of [0.3-0.6], [0.6-1.0], [1.0-1.6], [1.6-2.2], [2.2-3.5], [3.5-5.0] and [5.0-7.0] keV, are used as input into the MBProj2D code. They mask out faint contaminating sources, and model the brighter ones. To account for the background, it is modelled using a local region. For a full description of the MBProj2D methodology, see Appendix A of B24, and its application for the B24 cluster parameter measurements is detailed in Section 5.1 of B24. The XGA analysis in this study and the analysis performed in B24 have the following analysis choices in common; fixing the metal abundance at ; use the Asplund et al. (2009) Solar abundance table; use values from HI4PI Collaboration et al. (2016); and use C-stat for the goodness of fit estimator.
Applying the methodology described in § 5.3, XGA measures for 47 of the 114 DES–XCS–eRO clusters using eROSITA data. B24 provides values for 50 of the DES-XCS-eRO sample. Of the 47 clusters measured by XGA, and 50 measured by B24, there are 30 clusters in common with successful21 measurements. The comparison of the 30 clusters in common is shown in Figure 9 (blue points) and a fit (assuming Equation (5) with fixed slope of ) to the data is given by the blue line and cyan shaded region highlighting the uncertainty. We find , consistent with a 1:1 relation. When the slope is left as a free parameter, the best fit value is .

Figure 9. The Xga measured versus those measured by B24 for the eROSITA telescope. The blue line is the best fit line, the cyan band around it represents the error on the line, and the red dashed line represents the 1:1 relation. The grey shaded regions from darkest to lightest represent the , and scatter.
We also constrain in the 0.5 - 2 keV band. B24 measures values of the 114 DES-XCS-eRO clusters. From the XGA analysis, we measure 76 values for the DES-XCS-eRO sample (all in common with B24). We present the comparison of these measurements in Figure 10 (blue points). We fit Equation (5) to the data with fixed slope of . We find , consistent with a 1:1 relation. When the slope is left as a free parameter, the best fit value is .

Figure 10. The Xga measured in the 0.5 - 2 keV band versus those measured by B24. The blue line is the best fit line, the cyan band around it represents the error on the line (note that the cyan band is difficult to distinguish in the plot due to the tight constraints in the fit), and the red dashed line represents the 1:1 relation. The grey shaded regions from darkest to lightest represent the , and scatter.
Summary of Sample Comparison Analysis
In summary, we have validated that the methodology outlined in § 5.3 is reliable when applied to the analysis of eROSITA observations of clusters made in survey mode, specifically the measurement of luminosities and of temperatures (both global () and core excised). We have done this by comparison to XGA measurements published values in M24 and B24.
Cross-Calibration of XMM and eROSITA
We have shown above that the XGA processing of eROSITA observations is robust (§ 5.4 and § 6). Similarly the XGA processing of XMM observations was validated in T25. Therefore, we can now confidently compare the XGA analysis of clusters observed by both telescopes to establish their relative cross calibration. For this, we make measurements of , , and for the DES-XCS-eRO sample (outlined in § 4.2) using eROSITA and XMM. For all comparisons between the two telescopes we fit a power law described by Equation (5). We perform fits both with the slope fixed to 1 and with the slope free to vary. The latter allows us to investigate the dependence of any measured offsets with the X-ray property in question. We present the fit parameters in Table 4.
Table 4. Fit values comparing eROSITA and XMM measurements of , , and . The ‘Normalisation’, ‘Slope’, and ‘Scatter’ columns are the value of , , and respectively in Equation (5), with the ‘’ and ‘’ columns defined in the same equation. results are for the sample with a minimum count threshold of 150, as measured by B24. The and relations with a sample size of 37 use an identical set of clusters to the relation.
Cross-calibration of temperature
Xga successfully21 measures global () values for 47 and 103 clusters with eROSITA and XMM respectively. There are 44 clusters with successful measurements by both telescopes. We find that XMM typically measures higher values than eROSITA, finding a normalisation of , with the slope fixed at 1, see Figure 8. ure 11. When allowing the slope to vary, we find an offset of for clusters measured by eROSITA at 3 keV, and an offset of for clusters measured by eROSITA at 10 keV.
Previous calibrations of galaxy cluster observations with eROSITA and XMM have also reported that XMM measures higher values than eROSITA, notably by T22 and M24. T22 found XMM measured values higher than eROSITA. M24 finds XMM measures
and higher for clusters measured at 3 keV and 10 keV with XMM respectively. While our results are not in significant tension with these previous studies (due to the large errors on the measured offset), the difference warrants further scrutiny. In Figure 11, the symbols are colour-coded by eROSITA counts, which are taken directly from B24 in the “CTS500” column. It can be seen that clusters with low counts () in eROSITA tend to lie the furthest from the 1:1 relation. Notably, at an XMM estimated keV, the eROSITA measured values range from to 10 keV. This large range in eROSITA measured values is likely artificial, due to the lower signal to noise of eRASS1 detections compared to XMM: for all 47 clusters, the XMM source counts are higher, with a median factor of 52, than those from eROSITA.

Figure 11. The Xga eROSITA measured values for versus Xga XMM measured. The blue line is the best fit line, the cyan band around it represents the error on the line, and the red dashed line represents the 1:1 relation. The grey shaded regions from darkest to lightest represent the , and scatter. The points are coloured according to their eROSITA counts, as reported in the “CTS500” column in B24. We limit the range of the colour bar from 0 - 1000 counts.
In order to quantify the effect of eROSITA counts on the XMM offset, we excluded clusters under a minimum eROSITA count threshold and repeated the comparison. We repeated the fits for 8 minimum eROSITA count thresholds, starting at 0 counts (i.e., including all clusters in the DES-XCS-eRO sample), and up to a minimum eROSITA measured count of 400. The eROSITA - XMM offset as a function of count threshold is shown in Figure 12. It is found that for a minimum eROSITA count of >150, the measured offsets fluctuate around an offset of ~30%. Below a minimum threshold of 150 eROSITA counts, the value of the offset increases. We visually inspected the spectra of clusters with <150 counts, which revealed that there was negligible signal beyond 2 keV, where the sensitivity of eROSITA drops off steeply. This lack of detected higher energy photons causes eROSITA to erroneously measure keV. We therefore draw the conclusion that measurements of with eROSITA using the Xga method are only reliable for spectra generated within regions that have counts of 150 and above.
Figure 13 shows the eROSITA - XMM offset for clusters with more than 150 counts in eROSITA. We find that XMM measures higher values than eROSITA, and recover for a fixed slope. We also allow the slope to vary in the fit, measuring . Therefore, unlike M24, we find no evidence of a -dependent offset. We attribute the discrepancy with M24 to the different samples used in the two works: 58% of the M24 sample have an eROSITA keV, compared to 87% in this work. The slope measured here is therefore driven largely by hotter clusters, whereas the slope in M24 is weighted more evenly between the cool and hot cluster populations. Indeed, our measured offset of 287% is consistent with the 32% offset measured at 10 keV in M24.
Figure 13. The XGA eROSITA measured values versus XGA XMM measured ones, cutting the sample by a minimum of 150 counts measured by eROSITA. For the fit with a varying slope: the blue line is the best fit line, the cyan band around it represents the error on the line, and the light blue shaded region represents the error for the fit with a fixed slope: the dark purple line is the best fit line, the purple band around it represents the error on the line, and the light purple shaded region represents the scatter. The red dashed line represents the 1:1 relation.
Cross-calibration of luminosity
XGA measures for 76 and 106 clusters with eROSITA and XMM respectively, providing 73 clusters with measurements from both observatories. For the bolometric bandwidth (0.1-10.0 keV), one additional XMM measurement was obtained. Figure 14 shows the eROSITA measurements of and compared to XMM. In both cases we find that XMM measures higher luminosity values than eROSITA, finding a normalisation of and for and respectively.
To test for an luminosity dependence in the offset, we allow the slope parameter () of Equation (5) to vary. For , we obtain , corresponding to an XMM that is % higher than eROSITA at erg s, and consistent with parity at erg s. For , allowing the slope to vary yields , implying XMM values that are 50 10% higher than eROSITA at erg s, and 26 8% higher at erg s.
Bolometric X-ray luminosities scale as , while soft-band luminosities follow a weaker dependence, (see Section 2.1 in Lovisari et al. 2021, for details). This amplifies any systematic offset in between eROSITA and XMM, and could naturally contribute to the larger offset observed in relative to . A further contributing factor may arise from the effects of modelling a multi-temperature ICM with a single-temperature model, the impact of which is discussed in § 9.1.
To explore the dependence of the luminosity offset on the constraint, we repeated the luminosity comparisons for the subsample of 37 clusters which had a successfully measured value (§ 7.1). We find no significant difference in the fit parameters between the well constrained subsample and the full luminosity subsamples, as shown in Table 4, no fit values vary by more than . T22 compared for eROSITA eFEDS clusters and XMM, finding them to be consistent. It is worth noting that the T22 comparison was made within a fixed 500 kpc aperture, whereas the comparison presented in this work uses taken from B24. A further factor that may contribute to any discrepancy is the depth of the eFEDS data, which is a factor deeper than eRASS1. In addition, B24 compared their eROSITA eRASS1 measurements to those from Chandra, and found the eROSITA values to be systematically lower, by approximately 15%. This offset is consistent with the difference measured in this work.
X-ray - Optical Scaling Relations
Having established and offsets between XMM and eROSITA (§ 7), we can now explore whether it will be possible to combine XMM and eROSITA observations to improve cluster cosmology studies, specifically through a better understanding of the X-ray - richness relations - and -. The XMM and eROSITA relations are derived using identical subsets of DES-XCS-eRO clusters, namely, those for which successful20 measurements were obtained from both telescopes.
For this, we modify Equation (5) by accounting for redshift evolution, , giving the following:
where , assuming and . We set to and for the - and - relations respectively, which come from the self-similar expectation. We set and to the median values of the data, which are listed in Table 5, alongside the fit results.
| Relation | Telescope | Normalisation | Slope | Scatter | Sample Size |
| , | |||||
| - | eROSITA | 73 | |||
| - | eROSITA | 37 | |||
| - | XMM | 73 | |||
| - | XMM | 37 | |||
| , | |||||
| - | eROSITA | 37 | |||
| - | XMM | 37 |
Table 5. Fit values of the - and - relations, measured with XGA using eROSITA and XMM for the same cluster sample. The ‘Normalisation’, ‘Slope’, and ‘Scatter’ column are the values of , , and respectively in Equation (6). For the - relation, and correspond to and , while for the - relation, they correspond to and . The fitted relations are shown in Figure 15. The relations with a sample size of 37 use an identical set of clusters to the relation.
The left panel of Figure 15 shows the - scaling relation using XMM (pink points) and eROSITA (blue points). XMM and eROSITA measure consistent slopes of and respectively. eROSITA measures a slightly lower normalisation than XMM ( compared to ), which is expected given that eROSITA measures less than XMM (Table 4). The measured scatter is similar, with XMM and eROSITA measuring and respectively. Similar to § 7.1, we repeated the scaling relation fit for - using the subsample of 37 clusters with well constrained . We find no significant difference in the fit parameters between the well constrained subsample and the full subsample.
Figure 15. The - relation (left) and the - relation (right), each for the same cluster sample, measured with XGA for eROSITA (blue) and XMM (pink). The dark lines show the best-fit relations, with the surrounding cyan (eROSITA) and pink (XMM) bands indicating the uncertainty on the fits. The light shaded regions correspond to the intrinsic scatter.
The right panel of Figure 15 shows the - relation. XMM and eROSITA measure consistent slopes of and respectively. eROSITA measures a lower normalisation than XMM ( compared to ), which is expected given that eROSITA measures less than XMM (Table 4). The measured scatter is similar, with XMM and eROSITA measuring and respectively.
These results highlight that the choice of observatory does not have a significant impact on the slope or scatter of the derived X-ray - richness relations. To our knowledge, this study is the first to compare X-ray - optical scaling relations between XMM and eROSITA. However, Kelly et al. (2024) performed a similar comparison between XMM and Chandra. They found that the - relation exhibits a steeper slope when measured with XMM than with Chandra ( versus ), along with a marginally smaller intrinsic scatter ( and respectively). Hence, it is not unexpected that our measured relations are instrument dependent.
That said, our XMM - slope () is shallower than that of Kelly et al. (2024) and of Giles et al. (2022) ( and respectively). In principle, the scaling relations derived from a single instrument should be consistent. However, in practice the measured relations are a strong function of the selection function. Our XMM relation is derived from a sample that is additionally required to be detected by eROSITA. Owing to the shallow depth of eRASS1 relative to the XMM observations, this selection preferentially includes the brightest clusters at a given , particularly at low richness. These systems are expected to have systematically higher , and hence , values, which acts to flatten the measured slope (Mantz et al. (2010)). Future releases of eROSITA photon data should alleviate this bias, because longer exposure times will allow the detection of fainter systems. We note that the scatter on the - relation measured in this study is consistent with that measured by Kelly et al. (2024), vs .
In summary, this analysis has shown that the slopes and scatter of scaling relations derived from two different telescopes (eROSITA and XMM) from the same clusters are consistent. This gives us confidence that it will be possible to combine clusters detected by only one of the telescopes to improve the statistical accuracy, extend the mass range, and explore evolution in the scaling relations (assuming a well defined selection function). This is because, generally speaking, the XMM archive probes to lower masses and/or higher redshifts than eRASS1, due to its longer exposure time, whereas eRASS1 delivers more of the rare high mass systems, due to its larger footprint. We note that even though the normalisation of the scaling relations will be offset between the telescopes, due to the effects described in § 7, but this can be compensated for by scaling, as was done in Kelly et al. (2024) (where Chandra measurements were scaled to XMM for joint fits).
Discussion
The cross-calibration between XMM and eROSITA and measurements (see § 7) shows that XMM consistently measures higher values than eROSITA, with the discrepancy being larger ( offset) for compared to ( offset). A similar trend is seen for , where XMM measures higher values than eROSITA.
Two arguments are typically invoked to explain systematic measurement offsets between X-ray observatories. First the effect of modelling a multi-temperature gas with a single-temperature model. Second, calibration discrepancies in the effective area calculations. We explore these two arguments below.
Effect of a multi-temperature ICM
This study uses a constanttbabsapec model to fit spectra, which assumes that the ICM is a single temperature plasma. This is an oversimplification; it is well known that many clusters have cool cores and/or temperature structures in their outskirts (e.g. A3158, Figure 5). However, due to the signal to noise limitations of eRASS1 observations, it is not practical to try to fit to a more complex model. Given the differing shape of the eROSITA and XMM effective areas, each telescope will be sensitive to different components of a multi-temperature gas for a given cluster. Notably, the effective area of eROSITA above ~2 keV drops significantly compared to that of XMM (see Figure 9 of Predehl et al. (2021)). Therefore, fits to eROSITA spectra, under the assumption of a single temperature ICM, will be biased by the cooler components of a multi temperature ICM. Therefore, we can expect eROSITA to measure both lower global temperatures and luminosities than XMM. Although eROSITA has slightly larger sensitivity in the 0.5–2 keV band, XMM measures higher values because is proportional to the integrated model (which is fitted over 0.3–7.9 keV), so it is influenced by XMM’s high-energy response. The offsets will be larger for , than for , because the bolometric band includes the energy range where XMM’s effective area exceeds eROSITA’s.
Observational biases of spectroscopic measurements arising from thermal structures in the ICM propagate into biases in hydrostatic mass. As shown in Rasia et al. (2014); Henson et al. (2017); Pearce et al. (2020); Barnes et al. (2021), spectroscopic measurements differ from the true thermal temperatures of simulated clusters, and when used to calculate hydrostatic mass, biases of up to 40% are induced.
Other cross-calibration studies such as M24 and Lopez et al. (2025) run comparisons, excluding the projected core, where the most significant multi-temperature structure along the line-of-sight is expected. M24 provide a comparison of the temperature cross-calibration in two annular regions: a core region, and an outer annulus excluding the core. In the core region, the line of sight is intersected by multiple gas temperatures, within an outer annulus, only the outskirts of the cluster is considered. M24 finds there is no significant difference in the cross-calibration between the core and outer annulus temperatures. Furthermore, M24 simulate a range of cluster spectra consisting of cool and hot gas components, which is then fit by a single temperature model. Performing this exercise for eROSITA, XMM and Chandra, M24 find that while eROSITA measures consistently lower temperatures, the difference compared to XMM and Chandra is always .
In this work we do not exclude the core, since the sample does not have sufficient counts to do so, and still measure a reliable value. However, the M24 results described above demonstrate that the cross-calibration differences found in § 7 cannot be fully explained by the use of single temperature fits to multi-temperature gas.
Calibration of the effective area
If the ICM has a single-temperature, but measured parameters are offset between different observatories, then it is possible that calibration of the respective effective areas is the cause. It is standard practice for X-ray cross-calibration studies of clusters to repeat fitting across soft and hard energy bands. Doing so can give an insight into which energy ranges are driving the calibration inconsistencies. We therefore repeated spectral fitting using the same sample explored in § 7, using the 0.4 - 5.0 keV (soft) and 1.5 - 7.0 keV (hard) bandpasses (as performed in M24). The fit to the soft band, yielded a full set (37) of successful20 measurements, we measure an offset of 30±10% at an eROSITA of 3 keV and a slope of 1.0±0.2, consistent with the offset and slope obtained from the full 0.3-7.9 keV band. Our results are comparable to M24, who found that soft and full band measurements agree within .
Unfortunately, the fit to the hard band yielded only 11 successful20 measurements, insufficient to constrain a reliable offset. The number of sources with measurable values in this band is limited by the declining sensitivity of eROSITA above keV, leading to low signal in the hard band. As a result, the spectral fits lack sufficient constraining power to yield model parameters with uncertainties meeting our quality criterion of a fractional uncertainty less than 0.8. This lack of constraint in the hard band means we are unable to draw conclusions regarding potential calibration uncertainties in the observatories. It may be possible to do so after future releases of eRASS photon data, these will improve the signal to noise of the eROSITA observations of the DES-XCS-eRO sample.
In their hard-band (1.5 - 7.0 keV) analysis, M24 similarly found that fewer clusters yielded reliable measurements with eROSITA. However, they did report an offset of 55% at an XMM of 3 keV (see their Figure 3). This was based on a poorly constrained hard band relation, i.e. a slope of 0.442 ± 0.205, compared to 0.825 ± 0.074 for their full-band relation, but M24 were able to make the conclusion that the eROSITA–XMM cross-calibration was better in the soft band and for cooler clusters than in the hard band and for hotter clusters, attributing this to the effective area calibration of eROSITA being better matched to XMM at low energies.
Conclusion
In this work we present the first application of the XGA and DAXA software packages to eROSITA data. We have validated our methods using both pointed and survey eROSITA observations. First, we leveraged the eROSITA CAL-PV pointed observation of A3158. We measured radial profiles of temperature with XGA for A3158 that are consistent in shape with those from W22. We also showed that derived profiles, including gas density, and hydrostatic mass, show close agreement between eROSITA and XMM. Second, we used comparisons to M24 and B24 to demonstrate that the XGA method provides robust measurements of the following when eROSITA is operated in survey mode: cluster temperature within (), annular temperature from 0.2 - 0.5 (), and luminosity across the 0.5 - 2.0 keV band ().
We then applied XGA to a sample of 114 Dark Energy Survey redMaPPer galaxy clusters that have been detected in X-ray by both XMM and eROSITA (the DES-XCS-eRO sample). Of these 114, values were measured by XGA for 76 (eROSITA) and 105 (XMM) clusters. An additional cluster had an XMM luminosity measured across the 0.1 - 10.0 keV band . Modelling the offsets using a power-law with a fixed slope, we reveal that XMM measures 19 ± 6% and 34 ± 7% higher and values than eROSITA respectively. Allowing the slope of the power-law to vary indicates a -dependent offset: XMM is 18 ± 5% higher at erg s, and consistent with eROSITA at erg s. For , offsets range from at erg s to at erg s.
Of the 114 DES-XCS-eRO clusters, eROSITA and XMM provided measurements for 47 and 103 clusters respectively. Applying a 150-count minimum for eROSITA left 37 clusters suitable for cross-calibration. Comparisons of the measurements show that XMM measures higher values on average. Unlike M24, no evidence of a -dependence in the calibration was found.
Scaling relations of - and - were fitted for both observatories. The - relation shows minimal difference between eROSITA and XMM, while the - normalisation differs significantly: (eROSITA) versus (XMM), though slopes are consistent within ( vs ). The scatter on the - relation is larger than that of the - relation (by at least a factor of 2).
We have thus demonstrated that cluster cosmology studies can leverage X-ray measurements from either observatory, without requiring individual clusters to be detected by both. Moreover, we have shown that measurements – which require lower signal-to-noise than measurements – can be used to constrain the mass observable relations. This is particularly relevant for samples of clusters with significant overlap with eRASS1 (from which measurements are readily available, but measurements are not). For example, samples derived from wide area optical/near-IR photometric surveys such as the DES Y3 redMaPPer catalogue, which has eRASS1 and XMM corresponding detections (with the DES-XCS-eRO sample representing the overlap between these two samples). Our findings are also applicable to cluster samples detected via the Sunyaev-Zel’dovich Effect. For example the 10,040 clusters in the Atacama Cosmology Telescope’s (ACT) DR6 (Aguena et al. 2026), of which 1,904 have a match in the eRASS1 cluster catalogue and 712 have a match to an extended XCS source, with 251 clusters in common.
Acknowledgements
We thank the anonymous referee for their helpful comment regarding the choice of abundance table.
PG, KR, RW, JP, and recognise support from the UK Science and Technology Facilities Council via grants ST/T000473/1 and ST/X001040/1 (PG, KR), ST/X508822/1 (JP), ST/P006760/1 (RW). DT is supported by NASA under award number 80GSFC24M0006. MH acknowledges financial support from the National Research Foundation. This work is based on data from eROSITA, the soft X-ray instrument aboard SRG, a joint Russian-German science mission supported by the Russian Space Agency (Roscosmos), in the interests of the Russian Academy of Sciences represented by its Space Research Institute (IKI), and the Deutsches Zentrum für Luft- und Raumfahrt (DLR). The SRG spacecraft was built by Lavochkin Association (NPOL) and its subcontractors, and is operated by NPOL with support from the Max Planck Institute for Extraterrestrial Physics (MPE). The development and construction of the eROSITA X-ray instrument was led by MPE, with contributions from the Dr. Karl Remeis Observatory Bamberg & ECAP (FAU Erlangen-Nuernberg), the University of Hamburg Observatory, the Leibniz Institute for Astrophysics Potsdam (AIP), and the Institute for Astronomy and Astrophysics of the University of Tübingen, with the support of DLR and the Max Planck Society. The Argelander Institute for Astronomy of the University of Bonn and the Ludwig Maximilians Universität Munich also participated in the science preparation for eROSITA. The eROSITA data shown here were processed using the eSASS software system developed by the German eROSITA consortium.
Data Availability
The XMM data underlying this article were accessed from the XMM science archive at https://nxsa.esac.esa.int/nxsa-web/.
The eROSITA cluster catalogue used in this work is publicly available at https://erosita.mpe.mpg.de/dr1/AllSkySurveyData_dr1/Catalogues_dr1/, and the underlying eROSITA data are accessible via the eROSITA-Data Release 1 portal at https://erosita.mpe.mpg.de/dr1/erodat/.
The redMaPPer catalogue used in this paper is publicly available at https://des.ncsa.illinois.edu/releases/y3a2/Y3key-cluster.
The data underlying the results in this article are available in the accompanying GitHub repository found at https://github.com/jessicapilling/eRO-XMM_Cross_Calibration.
Masking the Cool Gas Extension in A3158
The initial comparison to W22 in Figure 6 shows consistent agreement with eROSITA except between kpc. This is the same region as the cool gas extension reported in W22. To investigate whether this cool gas was driving the difference in the temperature profile at kpc, this region was masked with three ellipses applied to eROSITA and XMM data, as seen in Figure A1.

Figure A1. Masking used in eROSITA and XMM temperature profile generation (seen in Figure A2), where the proposed cool gas extension location is approximately masked in the overlapping green ellipses.
The same analysis, whereby the default Xga method was altered to best match the W22 methodology was used to measure a temperature profile for eROSITA and XMM. These results are shown in Figure A2, where all eROSITA points now appear consistent with W22.

Figure A2. Projected temperature profile of A3158 measured with Xga for XMM (pink) and eROSITA (blue), compared with previous measurements by W22 for XMM (orange) and eROSITA (purple). The equivalent to Figure 5, except masking the cool gas extension using the masks shown in Figure A1.
References
- [1]Abbott T. M. C., et al., 2018, Phys. Rev. D, 98, 043526
- [2]Abbott T. M. C., et al., 2020, Phys. Rev. D, 102, 023509
- [3]Abbott T. M. C., et al., 2025, Phys. Rev. D, 112, 083535
- [42]Planck Collaboration et al., 2016, A&A, 594, A24
- [69]XRISM Science Team 2020, arXiv e-prints, p. arXiv:2003.04962arxiv.org/abs/2003.04962




