betaFeedback

WorksPhysics and Astronomy

Li2_2100depl^{100\textrm{depl}}MoO4_4 Scintillating Bolometers for Rare-Event Search Experiments

Abstract

We report on the development of scintillating bolometers based on lithium molybdate crystals containing molybdenum depleted in the double-ββ active isotope 100^{100}Mo (Li2_2100depl^{100\textrm{depl}}MoO4_4). We used two Li2_2100depl^{100\textrm{depl}}MoO4_4 cubic samples, 45 mm side and 0.28 kg each, produced following purification and crystallization protocols developed for double-ββ search experiments with 100^{100}Mo-enriched Li2_2MoO4_4 crystals. Bolometric Ge detectors were utilized to register scintillation photons emitted by the Li2_2100depl^{100\textrm{depl}}MoO4_4 crystal scintillators. The measurements were performed in the CROSS cryogenic set-up at the Canfranc underground laboratory (Spain). We observed that the Li2_2100depl^{100\textrm{depl}}MoO4_4 scintillating bolometers are characterized by excellent spectrometric performance (∼\sim3–6 keV FWHM at 0.24–2.6 MeV γγ's), moderate scintillation signal (∼\sim0.3–0.6 keV/MeV depending on light collection conditions) and high radiopurity (228^{228}Th and 226^{226}Ra activities are below a few μμBq/kg), comparable to the best reported results of low-temperature detectors based on Li2_2MoO4_4 with natural or 100^{100}Mo-enriched molybdenum content. Prospects of Li2_2100depl^{100\textrm{depl}}MoO4_4 bolometers for use in rare-event search experiments are briefly discussed.

Introduction

Crystal scintillators are widely used in searches for rare-event processes (like two-ν\nu and ν\nu-less double-β\beta decays, rare α\alpha and β\beta decays, dark matter particles), particularly using technologies of low-temperature detectors [1, 2, 3, 4, 5]. Among them, molybdenum containing crystals represent a long-standing interest for double-β\beta decay searches [1, 2, 3, 4, 5], mainly in isotope 100Mo{}^{100}\mathrm{Mo} (possible also for 92Mo{}^{92}\mathrm{Mo} and 98Mo{}^{98}\mathrm{Mo} [6]); this isotope is also promising for solar and supernova neutrino detection [7, 8, 9, 10]. Different compounds with natural and a few ones with 100Mo{}^{100}\mathrm{Mo}-enriched molybdenum content have been developed and investigated as low-temperature detectors with simultaneous heat and scintillation detection, i.e. scintillating bolometers [1, 2, 3, 4, 5]. Lithium molybdate (Li2MoO4\mathrm{Li}_{2}\mathrm{MoO}_{4}) is found to be one of the most promising Mo-containing scintillators for such applications [11, 12, 13]. Natural and 100Mo{}^{100}\mathrm{Mo}-enriched Li2MoO4\mathrm{Li}_{2}\mathrm{MoO}_{4} (Li2100MoO4\mathrm{Li}_{2}{}^{100}\mathrm{MoO}_{4}) have been developed within the LUMINEU project and used in searches for 100Mo{}^{100}\mathrm{Mo} double-β\beta decay [13, 14, 15, 16]. The LUMINEU technology of scintillating bolometers has been adopted for CUPID-Mo double-β\beta experiment [17, 18, 19, 20]. Such detector material is also selected for CUPID [21, 22, 23, 24, 25] and CROSS [23, 25, 26, 27] projects, as well as it represents a great interest for the AMoRE experiment [28, 29, 30, 31, 32].

Lithium is also an element with a long-standing interest for rare-event search experiments. The dominant isotope, i.e. 7Li{}^{7}\mathrm{Li} (92% in natural lithium), is a light nucleus with non-zero spin, thus a viable candidate to probe spin-dependent dark matter interaction [33, 34]. Moreover, 7Li{}^{7}\mathrm{Li} is a good target to search for solar axions, via a resonant absorption of an axion by 7Li{}^{7}\mathrm{Li} and its subsequent γ\gamma deexcitation [11, 35, 36, 37, 38]. Last but not least, presence of 6Li{}^{6}\mathrm{Li} (8% in natural lithium) allows neutron detection via a 6Li(n,t)α{}^{6}\mathrm{Li}(\mathrm{n},\mathrm{t})\alpha reaction, characterized by a high cross-section to thermal neutrons; also, enrichment in 6Li{}^{6}\mathrm{Li} (up to 95%) is feasible and it can enhance the detection efficiency. Thus, Li-containing detectors are of special interest for neutron flux monitoring in rare-event search experiments [39, 40].

In this work we present development and investigation of scintillating bolometers based on a new type of the Li2MoO4\mathrm{Li}_{2}\mathrm{MoO}_{4} compound, produced from molybdenum depleted in 100Mo{}^{100}\mathrm{Mo} (Li2100deplMoO4\mathrm{Li}_{2}{}^{100\mathrm{depl}}\mathrm{MoO}_{4}). The low concentration of the double-β\beta active isotope 100Mo{}^{100}\mathrm{Mo} significantly reduces the related background counting rate, which is on the level of 10 mBq/kg in a Li2100MoO4\mathrm{Li}_{2}{}^{100}\mathrm{MoO}_{4} crystal (an order of magnitude lower for the natural one), and it can be a dominant internal background of this material. Therefore, Li2100deplMoO4\mathrm{Li}_{2}{}^{100\mathrm{depl}}\mathrm{MoO}_{4} looks more suitable than natural or 100Mo{}^{100}\mathrm{Mo}-enriched Li2MoO4\mathrm{Li}_{2}\mathrm{MoO}_{4} crystals for dark matter and axion search experiments with 7Li{}^{7}\mathrm{Li}, for double-β\beta decay searches in 92Mo{}^{92}\mathrm{Mo} and 98Mo{}^{98}\mathrm{Mo}, as well as for 6Li{}^{6}\mathrm{Li}-based neutron detection. Moreover, Li2100deplMoO4\mathrm{Li}_{2}{}^{100\mathrm{depl}}\mathrm{MoO}_{4} can be used in bolometric experiments to search for double-β\beta decay in 100Mo{}^{100}\mathrm{Mo}, as a complementary detector for better understanding a background model. Therefore, a goal of this work is to study prospects of Li2100deplMoO4\mathrm{Li}_{2}{}^{100\mathrm{depl}}\mathrm{MoO}_{4} low-temperature detectors for rare-event search applications.

Development and test of Li2100deplMoO4{}_{2}{}^{100\mathrm{depl}}\mathrm{MoO}_{4} scintillating bolometers

Crystals production and construction of detectors

In this study we used two Li2100deplMoO4\mathrm{Li}_{2}{}^{100\mathrm{depl}}\mathrm{MoO}_{4} scintillation crystals with a size of 45×45×4545 \times45 \times45 mm and a mass of around 0.28 kg each, identical to Li2100MoO4\mathrm{Li}_{2}{}^{100}\mathrm{MoO}_{4} crystal produced for the CROSS experiment [26]. The samples were cut from the same crystal boule grown by the low-thermal-gradient Czochralski technique, as detailed in [41]. A 4N purity lithium carbonate, selected for the LUMINEU and CUPID-Mo crystals production [13, 14, 17], and molybdenum oxide depleted in 100Mo{}^{100}\mathrm{Mo} (∼\sim0.01% of 100Mo{}^{100}\mathrm{Mo}; i.e. 1000 times lower than in natural Mo) have been used as starting materials. The 100deplMoO3{}^{100\mathrm{depl}}\mathrm{MoO}_{3} material purification, the solid-phase synthesis of the Li2100deplMoO4\mathrm{Li}_{2}{}^{100\mathrm{depl}}\mathrm{MoO}_{4} compound, and the crystal growth in a Pt crucible using the low-thermal-gradient Czochralski method (double crystallization approach) were realized following protocols of Mo-containing crystals production developed by LUMINEU [13, 14, 42] and adopted by

CUPID-Mo [17]. A large crystal boule (the cylindrical part is around ∅60×100\varnothing60 \times100 mm) has been grown with a crystal yield of about 80% from the initial charge [41] and two twin cubic samples (with a few mm chamfers) were produced.

The assembly of detectors have been carried out in an ISO class 4 clean room of the IJClab (Orsay, France). The first Li2100deplMoO4_2^{100\mathrm{depl}}\mathrm{MoO}_4 sample (LMO-depl-1), corresponding to the upper part of the boule, was mounted inside a Cu housing using polytetrafluoroethylene (PTFE) supporting elements and Cu screws, as shown in Figure 1 (Left). The holder design is rather similar to one used in bolometric measurements with the same-size Li2100MoO4_2^{100}\mathrm{MoO}_4 [23] and slightly larger TeO2_2 [43] crystals. The second Li2100deplMoO4_2^{100\mathrm{depl}}\mathrm{MoO}_4 sample (LMO-depl-2), corresponding to the bottom part of the boule, was assembled using Cu frames and columns, and PTFE pieces, as seen in Figure 1 (Middle). This sample was a part of a twelve-crystal array, in which all the other crystals are Li2100MoO4_2^{100}\mathrm{MoO}_4 [25]. The lateral side of the LMO-depl-2 crystal was surrounded by a reflective film (Vikuiti™) to improve the light collection, while the Cu housing of the LMO-depl-1 detector serves as a reflective cavity, however the aperture reduces a direct sight of the light detector. Thus, the light collection is non-optimal both due to a poor reflectivity of copper and low scintillation photons collection efficiency on the light detector(s).

Photographs of Li$_2^{100\mathrm{depl}}\mathrm{MoO}_4$ low-temperature detectors LMO-depl-1 and LMO-depl-2

Figure 1. Photographs of Li2100deplMoO4_2^{100\mathrm{depl}}\mathrm{MoO}_4 low-temperature detectors LMO-depl-1 (Left) and LMO-depl-2 (Middle). Both crystals have two epoxy-glued sensors; the left one is an NTD Ge thermistor, while the right one is a P-doped Si heater. Each scintillator was accompanied by a circular bolometric Ge light detector, as one seen in transparent of the crystal on the middle panel. An additional square-shaped Ge light detector (Right) was used for the LMO-depl-2 sample. All light detectors were instrumented with an NTD Ge sensor.

To detect particle interactions, each Li2100deplMoO4_2^{100\mathrm{depl}}\mathrm{MoO}_4 crystal was instrumented with a Neutron Transmutation Doped Ge [44] thermistor (NTD). A sensor with a size of 3×3×13 \times3 \times1 mm was epoxy glued onto the crystal’s surface using 6 spots of a bi-component glue (Araldite® Rapid). The temperature-dependent resistance of NTDs can be approximated as R(T)=R0⋅e(T0/T)0.5R(T) = R_0 \cdot e^{(T_0/T)^{0.5}} with the parameters R0∼1 ΩR_0 \sim1\ \Omega and T0∼3.7T_0 \sim3.7 K. The NTD sensors with similar irradiation parameters have been used in the CUPID-Mo experiment [17], and CUPID related R&D tests [22, 23, 24, 25]. Also, a P-doped Si heater [45] was glued on each crystal with a veil of the epoxy glue. This heating element is exploited to inject by Joules effect power, which can be used e.g. for the stabilization of the thermal gain [46], optimisation of the detector working point, heating of a device if necessary (as in CUPID-0 [47]), pile-up simulations [48]. To provide electrical contacts, the NTDs and heaters were wire-bonded using ∅25-μ\varnothing25\text{-}\mum Au wires.

To allow for the detection of Li2100deplMoO4_2^{100\mathrm{depl}}\mathrm{MoO}_4 scintillation, we accompanied crystals with bolometric detectors based on electronic-grade purity Ge wafers, supplied by Umicore (Belgium) [49]. Two of them have a circular shape (with a size of ∅45×0.18\varnothing45 \times0.18 mm each), while the third device is square-shaped (45×45×0.3045 \times45 \times0.30 mm). All the Ge disks are coated on both sides with a 70 nm SiO layer aiming at reducing the light reflection [17, 47, 50]. Smaller NTD sensors (3×1×13 \times1 \times1 mm or 3×0.7×13 \times0.7 \times1 mm) are attached to the Ge wafers with a veil of the epoxy glue. The Ge disks are PTFE-clamped in the Cu structure. A single circular light detector (LD-1-c) has been coupled to the LMO-depl-1 crystal, while both circular (LD-2-c) and square-shaped (LD-2-s) bolometric photodetectors viewed the LMO-depl-2 crystal. The mounted Ge light detectors are shown in Figure 1 (Middle and Right).

Operation at Canfranc underground laboratory

The Li2100deplMoO4_2^{100\mathrm{depl}}\mathrm{MoO}_4 scintillating bolometers were operated in the CROSS cryogenic set-up (C2U) [23, 51] at the Canfranc underground laboratory (LSC, Spain), providing a substantial reduction of the cosmic muon flux thanks to the rock overburden [52]. The detectors were assembled as parts of scintillating bolometer arrays and installed inside the cryostat, as illustrated in Figure 2. The facility exploits the HEXA-DRY dilution fridge by CryoConcept (France), which is equipped by the Ultra-Quiet Technology™ [53] to decouple a pulse tube (Cryomech PT415) from the dilution unit, thus reducing vibrations [54]. To further improve noise conditions, the detector arrays were spring-suspended from the cold plate of the cryostat. The detector volume inside the cryostat is shielded on the top by a 13 cm thick disk made of interleaved lead and copper (partially seen in Figure 2), while the outer vacuum chamber is surrounded by a 25 cm thick layer of low-radioactivity lead. In addition, a deradonized air flow around the cryostat had been supplied during the whole time of the experiment with the LMO-depl-2 detector.

Detector configurations in the C2U cryogenic runs at the LSC

Figure 2. Detector configurations in the C2U cryogenic runs at the LSC, in which Li2100deplMoO4\mathrm{Li}_2^{100\mathrm{depl}}\mathrm{MoO}_4 scintillating bolometers LMO-depl-1 (Left) and LMO-depl-2 (Right) were operated. Other scintillating bolometers are based on Li2MoO4\mathrm{Li}_2\mathrm{MoO}_4 crystals with natural (CROSS [55] and CLYMENE [56, 57] R&D) and 100Mo{}^{100}\mathrm{Mo}-enriched (joint CROSS and CUPID R&D [23, 25]) molybdenum content, as well as on natural and 116Cd{}^{116}\mathrm{Cd}-enriched CdWO4\mathrm{CdWO}_4 crystals [51, 58, 59, 60].

After reaching the base temperature of the cryostat (∼10\sim10 mK), we regulated the detector plate temperature at 18 and then 12 mK for measurements with the LMO-depl-1 bolometer, and at 14 mK for the LMO-depl-2 operation. The control and readout of bolometers was done with the help of a low-noise room-temperature DC front-end electronics, restyled from the Cuoricino experiment [61]. The data acquisition (DAQ) system was composed of two 12-channel boards with integrated 24-bit ADC and a programmable 6-pole Bessel-Thomson anti-aliasing filter (the cut-off frequency of the low-pass filter was set at 300 Hz) [62, 63].

In order to find an optimal working point of the detectors, representing the best signal-to-noise ratio, we spanned the bolometric response with respect to the current across an NTD [64]. We used heaters to inject thermal pulses to both Li2100deplMoO4_2^{100\mathrm{depl}}\mathrm{MoO}_4 bolometers, while LED generated photons, transmitted from a room-temperature LED (the emission maximum is at ∼880\sim880 nm) through an optic fibre, were exploited for the light detectors. The heater/LED signal injection was performed with the help of a wave-function generator (Keysight 33500B). As a result of the optimization, we polarized NTDs of the detectors at a few nA current, reducing NTD resistances from hundreds MΩ\Omega (at low power) to a few MΩ\Omega (at the working point).

For each operational temperature we performed measurements with a removable 232Th^{232}\mathrm{Th} γ\gamma source, made of a thoriated tungsten wire, and without the source (data are referred to calibration and background respectively). Even if the γ\gamma source is primarily conceived for calibration of the Li2100deplMoO4_2^{100\mathrm{depl}}\mathrm{MoO}_4 bolometers, we also used it to evaluate the energy scale of the light detectors similar to [17, 43].

The continuous data of each channel were acquired with a sampling rate of 2 kS/s and stored on a disk for the offline analysis. We processed data with the help of a MATLAB-based analysis tool [65], which implements the signal processing using the Gatti-Manfredi optimum filter [66] to maximize the signal-to-noise ratio. In order to apply the filter, we used data-based information about the signal shape (represented by an average signal of tens of high-energy events) and the measured noise (represented by 10000 waveforms with no signal). The data were triggered with a threshold corresponding to 5σ5\sigma of the filtered noise. For each triggered signal, we collected an information about its amplitudes (i.e. energy) and several pulse-shape parameters. The results of detectors characterization are presented in the next section.

Characterization of Li2100deplMoO4\mathrm{Li}_2^{100\mathrm{depl}}\mathrm{MoO}_4 scintillating bolometers

Performance of detectors

At first, we investigated the recorded bolometric signals in terms of time constants of the signal shape. The rising part of a signal is commonly characterized by the rise time parameter, which is computed as the time required by the signal to increase from 10% to 90% of its amplitude. The descending part is described by the decay time, defined here as the time required to drop from 90% to 30% of signal amplitude. The rise and decay time parameters of the operated low-temperature detectors are summarized in Table 1. We find that the Li2100deplMoO4\mathrm{Li}_2^{100\mathrm{depl}}\mathrm{MoO}_4 bolometers have signals with the rise time of ∼20\sim20 ms and the decay time ∼100\sim100 ms. These time constants are similar to the values reported for NTD-instrumented low-temperature detectors based on similar-size Li2MoO4\mathrm{Li}_2\mathrm{MoO}_4 crystals produced from molybdenum with the natural isotopic abundance and from enriched in 100Mo{}^{100}\mathrm{Mo} [12, 13, 17, 22, 23, 25]. The Ge light detectors, being gram-scale bolometric devices equipped with smaller NTDs (i.e. reduced heat capacity compared to the Li2100deplMoO4_2^{100\mathrm{depl}}\mathrm{MoO}_4 bolometers), have an order of magnitude faster response, typical for such devices [13, 17, 22, 23, 25, 47, 67].

BolometerTemperature (mK)Resistance of NTD (MΩ\Omega)Rise time (ms)Decay time (ms)Sensitivity (nV/keV)FWHMNoise_{Noise} (keV)FWHM (keV) at energy (keV)
LMO-depl-1182.416112173.66(3)5.9(10) at 1765
126.520115372.18(3)5.8(3) at 2615
LMO-depl-2143.01697293.80(3)6.8(3) at 2615
LD-1-c181.61.59.012000.097(1)0.174(4) at 5.9
122.61.610.513800.100(1)0.146(2) at 5.9
LD-2-s140.471.65.23800.343(5)0.94(6) at 17.5
LD-2-c144.42.07.822000.059(1)0.90(6) at 17.5

Table 1. Performance of Li2100deplMoO4_2^{100\mathrm{depl}}\mathrm{MoO}_4 scintillating bolometers and Ge light detectors. We report the detector plate temperature, the NTD resistance, the signal rise and decay time parameters, the detector sensitivity, the baseline noise resolution, and the energy resolution at a given energy.

Then, using an amplitude distribution of events recorded in the calibration runs, we calibrated the energy scale of bolometers and evaluated their sensitivity, expressed as a voltage amplitude per unit of a deposited energy (e.g. nV/keV), as well as their energy resolution in the limit of zero amplitude (baseline noise) and at a mono-energetic radiation. In order to calibrate the Li2100deplMoO4_2^{100\mathrm{depl}}\mathrm{MoO}_4 bolometers, we used the most intense γ\gamma quanta emitted by the 232Th^{232}\mathrm{Th} source in the energy interval of 0.2–2.6 MeV, as illustrated in Figure 3 (Left). In the background data we also relied on the presence of γ\gamma peaks from environmental radioactivity (mainly γ\gamma-active daughters of radon, 214Pb^{214}\mathrm{Pb} and 214Bi^{214}\mathrm{Bi}, examples are given below). The sensitivities of the Li2100deplMoO4_2^{100\mathrm{depl}}\mathrm{MoO}_4 bolometers were measured as ∼\sim20–40 nV/keV (see in Table 1); the LMO-depl-1 signal increases by a factor 2 at a colder temperature of the heat sink. Taking into account that the chosen working points are characterised by relatively high NTD currents, the achieved sensitivities are not exceptional among Li2_2MoO4_4-based bolometers (the highest reported values are ∼\sim100–150 nV/keV) [12, 13, 17, 22, 23, 25]. Also, the baseline noise is found to be rather low, ∼\sim2–4 keV FWHM (Table 1), and similar to early reported performance of NTD-instrumented Li2_2MoO4_4 bolometers (the best performing detectors have ∼\sim1 keV FWHM noise) [12, 13, 17, 22, 23, 25]. To further improve the baseline noise (e.g. for dark matter search applications), one can reduce the absorber’s volume (i.e. heat capacity) and/or use an advanced performance phonon sensor technology [34]. Despite of not extraordinary noise resolution, both Li2100depl_2{}^{100\mathrm{depl}}MoO4_4 bolometers show a comparatively high energy resolution as exampled in Figure 3 (Right). As it is also seen in Table 1, the energy resolution for high-energy γ\gamma quanta (1.8 and 2.6 MeV) is only a factor 2–3 worse than the resolution at zero energy, which is a good feature of Li2_2MoO4_4 bolometers [13]. Consequently, the Li2100depl_2{}^{100\mathrm{depl}}MoO4_4 energy resolution at the 2615 keV MeV γ\gamma’s, listed in Table 1 and illustrated in Figure 3 (Left, Inset), is among the best reported for Li2_2MoO4_4 low-temperature detectors [13, 17, 22, 23, 24, 25].

Figure 3. (Left) Energy spectrum of a 232Th^{232}\mathrm{Th} source measured with the Li2100deplMoO4_2^{100\mathrm{depl}}\mathrm{MoO}_4 (LMO-depl-1) bolometer, operated at 12 mK over 125 h. The most intense γ\gamma-ray peaks observed in the spectrum are labeled by their origin; D.E. and S.E. mean double and single escape peaks, respectively. A fit to the 2615 keV peak of 208Tl^{208}\mathrm{Tl} is shown in the inset; the energy resolution is 5.8(3) keV FWHM. (Right) The energy dependence of the Li2100deplMoO4_2^{100\mathrm{depl}}\mathrm{MoO}_4 (LMO-depl-1) bolometer energy resolution in calibration (red, 125 h) and background (blue, 1109 h) data acquired at 12 mK. The fit is shown by a dotted line.

Aiming a permanent calibration during measurements, the LD-1-c was supplied by an 55^{55}Fe X-ray source, which irradiated a Ge side opposite to the LMO-depl-1 crystal. This source emits a doublet of Mn Kα_{\alpha} and Kβ_{\beta} X-rays with energies of 5.9 and 6.5 keV, and intensities 25% and 3%, respectively; an example of the energy spectrum is presented in Figure 4 (Left). To overcome the absence of permanent X-ray sources in the assembly of the LMO-depl-2 scintillating bolometer, we irradiated this detector with the 232^{232}Th γ\gamma source to induce X-ray fluorescence of the materials close to the light detectors, i.e. in the Cu structure and in the crystal. An illustration of the resulting spectrum is shown in Figure 4 (Right). So, knowing the energy scale, we observed good sensitivity of two light detectors (1.2–2.2 μ\muV/keV), while the third device had a reduced value (0.4 μ\muV/keV) due to stronger polarization of NTD, as exhibited by lower NTD resistance (see Table 1). This performance is typical for such type of bolometric detectors with NTD thermistors; a further gain is also feasible by reducing heat capacity of the sensor / absorber (e.g. see in [13] and references therein) and/or upgrading with Neganov-Trofimov-Luke-effect-based signal amplification [64]. The less sensitive light detector had comparatively modest noise resolution (about 300 eV FWHM), while the other two detectors demonstrated a rather low noise, 60–100 eV FWHM (e.g. see in [4]). The resolution of the 6 keV X-ray peak is found to be close to the baseline noise value, while a more broader 17 keV Mo X-ray peak has been detected by both light detectors irrespective of 5 times difference in the baseline noise. This effect can be explained by a position-dependent response of such thin bolometers [13].

Figure 4. Energy spectra of X-rays from a close 55^{55}Fe X-ray source (Left) and Cu / Mo X-rays induced by the 232^{232}Th γ\gamma-ray source (Right), measured by the LD-1-c (1109 h of background data) and LD-2-c (266 h, calibration) bolometers respectively. Fits to the spectra with two Gaussians and a linear background component are shown by solid red lines.

Scintillation detection and particle identification

A combination of both heat and scintillation channels of a scintillating bolometer can provide particle identification, exploiting the dependence of the light output on the energy loss mechanism (i.e. particle type) [4, 68]. In order to find coincidences between signals in the Li2depl100MoO4\mathrm{Li}_2{}^{100}_{\mathrm{depl}}\mathrm{MoO}_4 bolometers and in the associated light detectors, the latter channels were processed using trigger positions of Li2depl100MoO4\mathrm{Li}_2{}^{100}_{\mathrm{depl}}\mathrm{MoO}_4 events and accounting for a difference in time response (see Table 1), similarly to [69]. It is convenient to present such data by normalizing the light detector signal on the corresponding heat energy release, the so-called light-to-heat parameter (L/H) in units of keV/MeV. The dependence of the L/H parameter on energy and type of particles impinged the Li2depl100MoO4\mathrm{Li}_2{}^{100}_{\mathrm{depl}}\mathrm{MoO}_4 detectors is illustrated in Figure 5.

Figure 5. Scintillation (light-to-heat parameter) versus heat energy release measured by the Li2depl100MoO4\mathrm{Li}_2{}^{100}_{\mathrm{depl}}\mathrm{MoO}_4 scintillating bolometers. Top panel, left shows a sum of calibration (125 h) and background (1109 h) data of the LMO-depl-1. The LMO-depl-2 events detected in background (top, right; 1536 h) and calibration (bottom; 111 h) measurements in coincidences with the bolometric photodetectors LD-2-c and LD-2-s, respectively.

Several populations of events are clearly seen in each data presented in Figure 5. The most dominant one, distributed mainly below 3 MeV, is originated by γ(β)\gamma(\beta) particles. We selected γ(β)\gamma(\beta)’s with energies above 2 MeV to evaluate the corresponding light-to-heat parameter (L/Hγ(β)_{\gamma(\beta)}), reported in Table 2. The lowest L/Hγ(β)_{\gamma(\beta)} value (∼\sim0.3 keV/MeV) is obtained for the LMO-depl-1 and it is expected due to sub-optimal scintillation light collection conditions (e.g. the aperture between the crystal and the photodetector, the Cu surrounding instead of a reflective foil, smaller light-detector area). Indeed, the twin detector (LMO-depl-2), being surrounded by the reflective foil and coupled to the same-size photodetector, detected about 30% more scintillation energy (∼\sim0.4 keV/MeV), while the square-shaped light detector allowed almost to double the scintillation signal (∼\sim0.6 keV/MeV). At higher energies, above ∼\sim3 MeV, we see populations of events, which are characterised by scintillation reduced to ∼\sim20% compared to γ(β)\gamma(\beta)’s, as seen in Table 2. These events are originated by α\alpha’s from either U/Th traces of detector bulk / surface contamination or a U source and to α+t\alpha+t particles, products of neutron capture on 6Li^{6}\mathrm{Li}. Despite the different light collection conditions the characteristics of the Li2100deplMoO4\mathrm{Li}_{2}^{100\mathrm{depl}}\mathrm{MoO}_{4} scintillating bolometers, L/Hγ(β)_{\gamma(\beta)} and QFα_{\alpha} listed in Table 2, are similar to the ones reported for detectors based on Li2MoO4\mathrm{Li}_{2}\mathrm{MoO}_{4} crystals produced from molybdenum with the natural isotopic composition and enriched in 100Mo^{100}\mathrm{Mo} [13, 17, 22, 23, 24, 70].

CrystalPhotodetectorL/Hγ(β)_{\gamma(\beta)} (keV/MeV)QFα_{\alpha}
LMO-depl-1LD-1-c0.33(3)0.21(4)
LMO-depl-2LD-2-c0.44(3)0.19(4)
LMO-depl-2LD-2-s0.59(9)

Table 2. Results on scintillation detection with Li2100deplMoO4\mathrm{Li}_{2}^{100\mathrm{depl}}\mathrm{MoO}_{4} scintillating bolometers. We report the light-to-heat ratios for γ(β)\gamma(\beta) events (L/Hγ(β)_{\gamma(\beta)}) and the quenching factors for scintillation induced by α\alpha’s of 210Po^{210}\mathrm{Po} (QFα_{\alpha}).

Radiopurity of Li2100deplMoO4\mathrm{Li}_{2}^{100\mathrm{depl}}\mathrm{MoO}_{4} crystals

Thanks to efficient particle identification (Figure 5) and comparatively long background measurements, we can investigate radiopurity of the Li2100deplMoO4\mathrm{Li}_{2}^{100\mathrm{depl}}\mathrm{MoO}_{4} crystals with a high sensitivity to α\alpha-active radionuclides of the U/Th decay chains. With this aim, we selected α\alpha particles from the data of both detectors and re-calibrated spectra to alpha-energy scale for analysis of α\alpha contaminants, the resulting data are shown in Figure 6.

Figure 6. Energy spectra of α\alpha events detected by Li2100deplMoO4\mathrm{Li}_2^{100\mathrm{depl}}\mathrm{MoO}_4 scintillating bolometers made of crystals LMO-depl-1 (Left; 1109 h of measurements) and LMO-depl-2 (Right; 1528 h), operated underground in the C2U facility.

It is seen in Figure 6 that the α\alpha spectra of the Li2100deplMoO4\mathrm{Li}_{2}^{100\mathrm{depl}}\mathrm{MoO}_{4} crystals are rather similar with the exception of the energy region below ∼\sim4.7 MeV, which is populated by α\alpha particles from a 238U/234U^{238}\mathrm{U}/^{234}\mathrm{U} source used in the set-up nearby the LMO-depl-2 detector. The spectra contain only two peak-like structures, which is a clear indication of a high internal radiopurity. Moreover, the first peak at ∼\sim4.8 MeV is originated by the detection of products (α\alpha plus triton) of thermal neutron captures by 6Li^{6}\mathrm{Li}; this peak is detected by both bolometers with a similar rate of 1.8(2) counts/day. Furthermore, a doublet of 5.3 and 5.4 MeV peaks is a summed contribution of detector surface and crystal bulk contaminations by 210Po^{210}\mathrm{Po}; in the later case α\alpha particle and 206Pb^{206}\mathrm{Pb} nuclear recoil (taking away 0.1 MeV energy) were detected. The activity of 210Po^{210}\mathrm{Po} in both crystals is the same ∼\sim35 μ\muBq/kg; it is originated by a residual 210Pb^{210}\mathrm{Pb} contamination, typical for scintillators, particularly for Mo-containing compounds [13, 17, 71, 72, 73].

We found no clear evidence of other α\alpha-active radionuclides from U/Th chains in the α\alpha spectra of the Li2100deplMoO4\mathrm{Li}_{2}^{100\mathrm{depl}}\mathrm{MoO}_{4} detectors and thus we set upper limits on their activities in the crystal bulk, using the Feldman–Cousins approach [74]. As a signal, we took all events in the region ±\pm25 keV around a QQ-value of a radionuclide searched for, while background estimate is done in the neighbour energy interval out of the QQ-values of U/Th α\alpha’s, as e.g. detailed in [71]. The results of the study of Li2100deplMoO4\mathrm{Li}_2^{100\mathrm{depl}}\mathrm{MoO}_4 crystals radiopurity are summarized in Table 3. The limits on U/Th activity are obtained on the level of a few μ\muBq/kg; therefore radiopurity of the two Li2100deplMoO4\mathrm{Li}_2^{100\mathrm{depl}}\mathrm{MoO}_4 samples is similar to the purity level of Li2100MoO4\mathrm{Li}_2^{100}\mathrm{MoO}_4 crystals produced for LUMINEU [13, 15], CUPID-Mo [17, 70] and CROSS [23, 25] experiments, thanks to the same purification and crystallization protocols applied.

Crystal232^{232}Th [4082]228^{228}Th [5520]238^{238}U [4270]234^{234}U [4858]226^{226}Ra [4871]210^{210}Po [5407]
LMO-depl-1< 2< 2< 2< 5< 735(6)
LMO-depl-2< 2< 436(5)

Table 3. Radioactive contamination of the Li2100deplMoO4\mathrm{Li}_2^{100\mathrm{depl}}\mathrm{MoO}_4 crystals by α\alpha-active radionuclides from 238^{238}U/232^{232}Th families (their QQ-values are listed in keV). The uncertainties are given at 68% C.L., while the limits are set at 90% C.L.

Background reconstruction capability of Li2100deplMoO4\mathrm{Li}_2^{100\mathrm{depl}}\mathrm{MoO}_4 bolometers

As mentioned in § 1, 100^{100}Mo represents a great interest for double-β\beta decay studies. However, the two-ν\nu double-β\beta decay of 100^{100}Mo—characterized by a relatively “fast” half-life (∼7×1018\sim7 \times10^{18} yr [16, 75])—is an important source of background in ν\nu-less double-β\beta decay search experiments. Indeed, it generates a 10 mHz rate in a 1 kg 100^{100}Mo-enriched lithium molybdate crystal being a dominant background component in a wide energy interval [13, 19, 76]. But even crystals with natural Mo content have not negligible internal activity of 100^{100}Mo (∼1\sim1 mBq/kg). The impact of 100^{100}Mo radioactivity can be seen in Figure 7, where the energy spectra accumulated with 100^{100}Mo-enriched/depleted Li2MoO4\mathrm{Li}_2\mathrm{MoO}_4 bolometers in a common measurement at the C2U facility are shown. It is worth noting that the background of the Li2100MoO4\mathrm{Li}_2^{100}\mathrm{MoO}_4 bolometer was spoiled by a β\beta-component of the used external α\alpha source with a notable activity, around an order of magnitude higher than that of the 100^{100}Mo two-ν\nu double-β\beta decay, as evident in Figure 7. A clear γ\gamma background reduction exhibited by the LMO-depl-2 bolometer, in comparison to the LMO-depl-1 data, was achieved thanks to using a deradonized air flow around the cryostat shielding. Both Li2100deplMoO4\mathrm{Li}_2^{100\mathrm{depl}}\mathrm{MoO}_4 detectors have similar high background below 0.7 MeV, which is explained by a 210^{210}Bi activity induced by the 210^{210}Pb contamination of the lead shield. Also, the residual γ(β)\gamma(\beta) activity inside the experimental volume of the set-up, detected by both Li2100deplMoO4_2^{100\mathrm{depl}}\mathrm{MoO}_4 bolometers above ∼1\sim1 MeV is higher than e.g. in CUPID-Mo [19, 76], CUPID-0 [77, 78], and CUORE [79, 80]. Thus, the difference between the 100^{100}Mo two-ν\nu double-β\beta decay distribution and the background data of the Li2100deplMoO4_2^{100\mathrm{depl}}\mathrm{MoO}_4 detectors, acquired in not fully optimized background conditions, seen in Figure 7 is not remarkable as it might be in a better shielded set-up.

Figure 7. Energy spectra of γ(β)\gamma(\beta) events detected by bolometers based on 0.28 kg lithium molybdate crystals produced from molybdenum either depleted in 100^{100}Mo (pink, LMO-depl-1, and black, LMO-depl-2) or enriched in 100^{100}Mo (blue, LMO-enr data from [23]), and operated in the C2U set-up at the Canfranc underground laboratory. The detectors LMO-depl-1 and LMO-enr were running together (see Figure 2), while the LMO-depl-2 detector was measured in the next cryogenic run, in which the set-up was flushed with deradonized air. It is worth noting the LMO-enr bolometer was irradiated by a close 238^{238}U/234^{234}U α\alpha source, which emits β\beta particles too, 234^{234}Th (Qβ=0.27Q_{\beta} = 0.27 MeV) and 234m^{234\mathrm{m}}Pa (Qβ=2.2Q_{\beta} = 2.2 MeV). Thus, the difference between the acquired spectra is mainly explained by both the 100^{100}Mo two-ν\nu double-β\beta activity (∼3\sim3 mHz, Qββ=3.0Q_{\beta\beta} = 3.0 MeV) and the α\alpha-source-induced β\beta background (about 20 mHz of 234^{234}Th and 234m^{234\mathrm{m}}Pa) of the Li2100MoO4_2^{100}\mathrm{MoO}_4 detector. A Monte Carlo distribution of the 100^{100}Mo two-ν\nu double-β\beta decay events (green) [16] is shown for comparison.

It is evident on Figure 7 that the Li2100deplMoO4_2^{100\mathrm{depl}}\mathrm{MoO}_4 bolometer allows significantly improved reconstruction of γ\gamma background, including low-intensity contributions, compared to the Li2100MoO4_2^{100}\mathrm{MoO}_4 detector having a dominant double-β\beta (and β\beta) decay events continuum. Therefore, Li2100deplMoO4_2^{100\mathrm{depl}}\mathrm{MoO}_4 low-temperature detectors with high spectrometric performance and high radiopurity can provide a complementary information about a background model in double-β\beta decay searches with Li2100MoO4_2^{100}\mathrm{MoO}_4 bolometers. A similar example is the CUPID-0 experiment with 2 natural and 24 82^{82}Se-enriched zinc selenide bolometers [47], however the detectors from selenium with the natural isotopic concentration were not included to the background model analysis [77]. Moreover, a combination of Li2100deplMoO4_2^{100\mathrm{depl}}\mathrm{MoO}_4 and Li2100MoO4_2^{100}\mathrm{MoO}_4 bolometers of similar performance and purity would allow extracting a half-life and a spectral shape of the 100^{100}Mo two-ν\nu double-β\beta decay. A similar approach has been used in several double-β\beta searches, e.g. with 40Ca^{40}\mathrm{Ca}/48Ca^{48}\mathrm{Ca}-enriched calcium fluoride scintillation detectors [81], a 78Kr^{78}\mathrm{Kr}-enriched/depleted gas filled proportional counter [82], and a 136Xe^{136}\mathrm{Xe}-enriched/depleted xenon gas based time-projection chamber [83]. However, the enrichment in 48Ca^{48}\mathrm{Ca}, present in natural calcium at a ∼0.2%\sim0.2\% level, is not yet available in large quantity as for 100Mo^{100}\mathrm{Mo}, 78Kr^{78}\mathrm{Kr} and 136Xe^{136}\mathrm{Xe} [84]. Moreover, the very long half-lives of 78Kr^{78}\mathrm{Kr} (102210^{22} yr) and 136Xe^{136}\mathrm{Xe} (102110^{21} yr) require a huge exposure to collect a reasonably high statistics of double-β\beta decay events, while more than two orders of magnitude faster rate of 100Mo^{100}\mathrm{Mo} is an advantage for such study.

An order of magnitude lower background of the Li2100deplMoO4\mathrm{Li}_2{}^{100\mathrm{depl}}\mathrm{MoO}_4 bolometer at ∼0.5\sim0.5 MeV, compared to the Li2100MoO4\mathrm{Li}_2{}^{100}\mathrm{MoO}_4 one, would provide a higher sensitivity to a peak expected at 478 keV in case of a resonant absorption of solar axions to the first excited state of 7Li^{7}\mathrm{Li} and its subsequent γ\gamma deexcitation [11, 38]. At lower energies, the contribution of 100Mo^{100}\mathrm{Mo} two-ν\nu double-β\beta decay becomes negligible [23], making no preference on 100Mo^{100}\mathrm{Mo} content in Li2MoO4\mathrm{Li}_2\mathrm{MoO}_4 crystals for a search of spin-dependent dark matter interaction on 7Li^{7}\mathrm{Li}. At the same time the presence of 6Li^{6}\mathrm{Li} allows neutron detection (illustrated above in Figure 5 and Figure 6), which can be exploited for neutron flux monitoring, particularly relevant for dark matter search applications.

Conclusions

In the present study we demonstrate that scintillating bolometers made of lithium molybdate crystals produced from molybdenum depleted in 100Mo^{100}\mathrm{Mo} (Li2100deplMoO4\mathrm{Li}_2{}^{100\mathrm{depl}}\mathrm{MoO}_4) show high performance, comparable to the devices based on crystals from molybdenum of the natural isotopic composition or enriched in 100Mo^{100}\mathrm{Mo}. Thanks to the strict purification and crystallization protocols, developed and already applied to high-sensitivity searches for 100Mo^{100}\mathrm{Mo} ν\nu-less double-β\beta decay, radiopurity of Li2100deplMoO4\mathrm{Li}_2{}^{100\mathrm{depl}}\mathrm{MoO}_4 crystals is rather high and compatible to 100Mo^{100}\mathrm{Mo}-enriched crystals of the same production line. Thus, given an availability of molybdenum depleted in 100Mo^{100}\mathrm{Mo} (a by product of industrial enrichment in 100Mo^{100}\mathrm{Mo}) for Li2100deplMoO4\mathrm{Li}_2{}^{100\mathrm{depl}}\mathrm{MoO}_4 crystals production, as well as high spectrometric performance, efficient scintillation-assisted particle identification capability and high material radiopurity, Li2100deplMoO4\mathrm{Li}_2{}^{100\mathrm{depl}}\mathrm{MoO}_4 scintillating bolometers show a high potential for applications in rare-event search experiments. In particular such detectors represent a great interest for studies of 100Mo^{100}\mathrm{Mo} two-neutrino double-β\beta decay, to searches for 7Li^{7}\mathrm{Li} axions and spin-dependent interactions of dark matter particles on 7Li^{7}\mathrm{Li}, as well as for 6Li^{6}\mathrm{Li}-based neutron spectroscopy and γ(β)\gamma(\beta) background control measurements in low-temperature low-background experiments.

Funding: “This research received no external funding”

Acknowledgments: This work is supported by the European Commission (Project CROSS, Grant No. ERC-2016-ADG, ID 742345). This work was also supported by the National Research Foundation of Ukraine under Grant No. 2020.02/0011 and by the National Academy of Sciences of Ukraine in the framework of the project “Development of bolometric experiments for the search for double beta decay”, the grant number 0121U111684. Y.A.B., V.D.G., E.P.M., and V.N.S. were supported by the Ministry of Science and Higher Education of the Russian Federation N121031700314-5. Russian and Ukrainian scientists have given and give crucial contributions to CROSS. For this reason, the CROSS collaboration is particularly sensitive to the current situation in Ukraine. The position of the collaboration leadership on this matter, approved by majority, is expressed at https://a2c.jiclab.in2p3.fr/en/a2c-home-en/assd-home-en/assd-cross/. Majority of the work described here was completed before February 24, 2022.

Conflicts of Interest: “The authors declare no conflict of interest.” © 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).

References

  1. [1]Pirro, S.; Mauskopf, P. Advances in Bolometer Technology for Fundamental Physics. Annu. Rev. Nucl. Part. Sci. 2017, 67, 161.DOI
  2. [2]Bellini, F. Potentialities of the future technical improvements in the search of rare nuclear decays by bolometers. Int. J. Mod. Phys. A 2018, 33, 1843003.DOI
  3. [3]Biassoni, M.; Cremonesi, O. Search for neutrino-less double beta decay with thermal detectors. Prog. Part. Nucl. Phys. 2020, 114, 103803.DOI
  4. [4]Poda, D. Scintillation in Low-Temperature Particle Detectors. Physics 2021, 3, 473–535.DOI
  5. [5]Zolotarova, A. Bolometric Double Beta Decay Experiments: Review and Prospects. Symmetry 2021, 13, 2255.DOI
  6. [6]Tretyak, V.I.; Zdesenko, Y.G. Tables of double beta decay data — an update. At. Data Nucl. Data Tables 2002, 80, 83–116.
  7. [7]Ejiri, H.; Engel, J.; Hazama, R.; Krastev, P.; Kudomi, N.; Robertson, R. Spectroscopy of Double-Beta and Inverse-Beta Decays from 100Mo for Neutrinos. Phys. Rev. Lett. 2000, 85, 2917.pubmed.ncbi.nlm.nih.gov/11005967
  8. [8]Ejiri, H.; Engel, J.; Kudomi, N. Supernova-neutrino studies with 100Mo. Phys. Lett. B 2002, 530, 27–32.DOI
  9. [9]Ejiri, H.; Elliott, S.R. Charged current neutrino cross section for solar neutrinos, and background to ββ(0ν) experiments. Phys. Rev. C 2014, 89, 055501.
  10. [10]Ejiri, H.; Elliott, S.R. Solar neutrino interactions with the double-β decay nuclei 82Se, 100Mo, and 150Nd. Phys. Rev. C 2017, 95, 055501.
  11. [11]Cardani, L.; Casali, N.; Nagorny, S.; Pattavina, L.; Piperno, G.; Barinova, O.; Beeman, J.; Bellini, F.; Danevich, F.; Di Domizio, S.; others. Development of a Li2MoO4 scintillating bolometer for low background physics. J. Instrum. 2013, 8, P10002.DOI
  12. [12]Bekker, T.; Coron, N.; Danevich, F.; Degoda, V.Y.; Giuliani, A.; Grigorievа, V.; Ivannikova, N.; Mancuso, M.; De Marcillac, P.; Moroz, I.; others. Aboveground test of an advanced Li2MoO4 scintillating bolometer to search for neutrinoless double beta decay of 100Mo. Astropart. Phys. 2016, 72, 38.
  13. [13]Armengaud, E.; Augier, C.; Barabash, A.; Beeman, J.; Bekker, T.; Bellini, F.; Benoît, A.; Bergé, L.; Bergmann, T.; Billard, J.; others. Development of 100Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search. Eur. Phys. J. C 2017, 77, 785.
  14. [14]Grigorieva, V.D.; Shlegel, V.; Bekker, T.; Ivannikova, N.; Giuliani, A.; de Marcillac, P.; Marnieros, S.; Novati, V.; Olivieri, E.; Poda, D.; Nones, C.; Zolotarova, A.; Danevich, F. Li2MoO4 crystals grown by low thermal gradient Czochralski technique. J. Mat. Sci. Eng. B 2017, 7, 63.
  15. [15]Poda, D.V.; LUMINEU, EDELWEISS, CUPID-0/Mo collaborations. 100Mo-enriched Li2MoO4 scintillating bolometers for 0ν2β decay search: from LUMINEU to CUPID-0/Mo projects. AIP Conf. Proc. 2017, 1894, 020017.
  16. [16]Armengaud, E.; Augier, C.; Barabash, A.; Bellini, F.; Benato, G.; Benoît, A.; Beretta, M.; Bergé, L.; Billard, J.; Borovlev, Y.A.; others. Precise measurement of 2νββ decay of 100Mo with the CUPID-Mo detection technology. Eur. Phys. J. C 2020, 80, 674.
  17. [17]Armengaud, E.; Augier, C.; Barabash, A.; Bellini, F.; Benato, G.; Benoît, A.; Beretta, M.; Bergé, L.; Billard, J.; Borovlev, Y.A.; others. The CUPID-Mo experiment for neutrinoless double-beta decay: performance and prospects. Eur. Phys. J. C 2020, 80, 44.
  18. [18]Armengaud, E.; Augier, C.; Barabash, A.; Bellini, F.; Benato, G.; Benoît, A.; Beretta, M.; Bergé, L.; Billard, J.; Borovlev, Y.A.; others. New Limit for Neutrinoless Double-Beta Decay of 100Mo from the CUPID-Mo Experiment. Phys. Rev. Lett. 2021, 126, 181802.
  19. [19]Augier, C.; Barabash, A.; Bellini, F.; Benato, G.; Beretta, M.; Bergé, L.; Billard, J.; Borovlev, Y.; Cardani, L.; Casali, N.; Cazes, A.; others. Final results on the 0νββ decay half-life limit of 100Mo from the CUPID-Mo experiment. Eur. Phys. J. C 2022, 82, 1033.
  20. [20]Augier, C.; Barabash, A.; Bellini, F.; Benato, G.; Beretta, M.; Bergé, L.; Billard, J.; Borovlev, Y.A.; Cardani, L.; Casali, N.; others. New measurement of double-β decays of 100Mo to excited states of 100Ru with the CUPID-Mo experiment. Phys. Rev. C 2023, 107, 025503.
  21. [21]Armstrong, W.; Chang, C.; Hafidi, K.; Lisovenko, M.; Novosad, V.; Pearson, J.; Polakovic, T.; Wang, G.; Yefremenko, V.; Zhang, J.; others. CUPID pre-CDR. arXiv 2019, [arXiv:physics.ins-det/1907.09376].
  22. [22]Armatol, A.; Armengaud, E.; Armstrong, W.; Augier, C.; Avignone, F.; Azzolini, O.; Barabash, A.; Bari, G.; Barresi, A.; Baudin, D.; others. Characterization of cubic Li2 100MoO4 crystals for the CUPID experiment. Eur. Phys. J. C 2021, 81, 104.
  23. [23]Armatol, A.; Armengaud, E.; Armstrong, W.; Augier, C.; Avignone III, F.; Azzolini, O.; Bandac, I.; Barabash, A.; Bari, G.; Barresi, A.; others. A CUPID Li₂¹⁰⁰MoO₄ scintillating bolometer tested in the CROSS underground facility. JINST 2021, 16, P02037.
  24. [24]Alfonso, K.; Armato, A.; Augier, C.; Avignone III, F.; Azzolini, O.; Balata, M.; Barabash, A.; Bari, G.; Barresi, A.; Baudin, D.; others. Optimization of the first CUPID detector module. Eur. Phys. J. C 2022, 82, 810.arxiv.org/abs/2202.06279
  25. [25]Alfonso, K.; Armatol, A.; Augier, C.; Avignone III, F.; Azzolini, O.; Balata, M.; Bandac, I.; Barabash, A.; Bari, G.; Barresi, A.; others. Twelve-crystal prototype of Li₂MoO₄ scintillating bolometers for CUPID and CROSS experiments. Submitted to JINST 2023, [arXiv:physics.ins-det/2304.04611].DOI
  26. [26]Bandac, I.; Barabash, A.; Bergé, L.; Briere, M.; Bourgeois, C.; Carniti, P.; Chapellier, M.; de Combarieu, M.; Dafinei, I.; Danevich, F.; others. The 0ν2β-decay CROSS experiment: preliminary results and prospects. JHEP 2020, 01, 018.DOI
  27. [27]Bandac, I.; Barabash, A.; Bergé, L.; Bourgeois, C.; Calvo-Mozota, J.; Carniti, P.; Chapellier, M.; deCombarieu, M.; Dafinei, I.; Danevich, F.; others. Phonon-mediated crystal detectors with metallic film coating capable of rejecting α and β events induced by surface radioactivity. Appl. Phys. Lett. 2021, 118, 184105.DOI
  28. [28]Alenkov, V.; Aryal, P.; Beyer, J.; Boiko, R.; Boonin, K.; Buzanov, O.; Chanthima, N.; Chernyak, M.; Choi, J.; Choi, S.; others. Technical Design Report for the AMoRE 0νββ Decay Search Experiment. arXiv 2015, [arXiv:physics.ins-det/1512.05957].arxiv.org/abs/1512.05957
  29. [29]Kim, H.; Jeon, J.; Kim, I.; Kim, S.; Kim, H.; Kim, Y.; Kwon, D.; Lee, M.; So, J. Compact phonon-scintillation detection system for rare event searches at low temperatures. Nucl. Instrum. Methods Phys. Res. A 2020, 954, 162107.DOI
  30. [30]Kim, H.; Kim, H.; Kim, I.; Kim, S.R.; Kim, Y.; Kim, Y.H.; Kwon, D.; Jeon, J.A.; Lee, M.H.; Lee, M.; others. Li₂MoO₄ Phonon–Scintillation Detection Systems with MMC Readout. J. Low Temp. Phys. 2020, 199, 1082.
  31. [31]Kim, W.; Kim, S.; Sharma, B.; Jeon, J.; Kim, H.; Kim, S.; Kim, S.; Kim, Y.; Kim, Y.; Lee, H.; others. Test Measurements of an MMC-Based 516-g Lithium Molybdate Crystal Detector for the AMoRE-II Experiment. J. Low Temp. Phys. 2022, 209, 299–307.DOI
  32. [32]Kim, H.; Ha, D.; Jeon, E.; Jeon, J.; Jo, H.; Kang, C.; Kang, W.; Kim, H.; Kim, S.; Kim, S.; others. Status and Performance of the AMoRE-I Experiment on Neutrinoless Double Beta Decay. J. Low Temp. Phys. 2022, 209, 962–970.DOI
  33. [33]Bednyakov, V.A.; Šimkovic, F. Nuclear Spin Structure in Dark Matter Search: The Finite Momentum Transfer Limit. Phys. Part. Nucl. 2005, 37, S106–S128.DOI
  34. [34]Abdelhameed, A.; Angloher, G.; Bauer, P.; Bento, A.; Bertoldo, E.; Bucci, C.; Canonica, L.; D’Addabbo, A.; Defay, X.; Di Lorenzo, S.; others. First results on sub-GeV spin-dependent dark matter interactions with ⁷Li. Eur. Phys. J. C 2019, 79, 630.DOI
  35. [35]Krčmar, M.; Krečak, Z.; Ljubčić, A.; Stipčević, M.; Bradley, D.A. Search for solar axions using ⁷Li. Phys. Rev. D 2001, 64, 115016.DOI
  36. [36]Belli, P.; Bernabei, R.; Cerulli, R.; Danevich, F.; d’Angelo, A.; Gorilеtsky, V.; Grinyov, B.; Incicchitti, A.; Kob ychev, V.; Laubenstein, M.; others. ⁷Li solar axions: Preliminary results and feasibility studies. Nucl. Phys. A 2008, 806, 388–397.DOI
  37. [37]Barinova, O.; Danevich, F.; Degoda, V.Y.; Kirsanova, S.; Kudovbenko, V.; Pirro, S.; Tretyak, V. First test of Li₂MoO₄ crystal as a cryogenic scintillating bolometer. Nucl. Instrum. Methods Phys. Res. A 2010, 613, 54–57.DOI
  38. [38]Belli, P.; Bernabei, R.; Cappella, F.; Cerulli, R.; Danevich, F.; Incicchitti, A.; Kobychev, V.; Laubenstein, M.; Polischuk, O.; Tretyak, V.; others. Search for ⁷Li solar axions using resonant absorption in LiF crystal: Final results. Phys. Lett. B 2012, 711, 41–45.DOI
  39. [39]Martínez, M.; Coron, N.; Ginestra, C.; Gironnet, J.; Gressier, V.; Leblanc, J.; de Marcillac, P.; Redon, T.; Di Stefano, P.; Torres, L.; others. Scintillating bolometers for fast neutron spectroscopy in rare events searches. J. Phys.: Conf. Ser. 2012, 375, 012025.DOI
  40. [40]Coron, N.; Cuesta, C.; García, E.; Ginestra, C.; Gironnet, J.; de Marcillac, P.; Martínez, M.; Ortigoza, Y.; de Solórzano, A.O.; Puimedón, J.; others. Neutron Spectrometry With Scintillating Bolometers of LiF and Sapphire. IEEE Trans. Nucl. Sci. 2016, 63, 1967–1975.DOI
  41. [41]Grigorieva, V.D.; Shlegel, V.; Borovlev, Y.; Bekker, T.; Barabash, A.; Konovalov, S.; Umatov, V.; Borovkov, V.; Meshkov, O. Li₂¹⁰⁰MoO₄ crystals grown by low-thermal-gradient Czochralski technique. J. Cryst. Growth 2020, 552, 125913.DOI
  42. [42]Bergé, L.; Boiko, R.; Chapellier, M.; Chernyak, D.; Coron, N.; Danevich, F.; Decourt, R.; Degoda, V.Y.; Devoyon, L.; Drillien, A.; others. Purification of molybdenum, growth and characterization of medium volume ZnMoO₄ crystals for the LUMINEU program. JINST 2014, 9, P06004.DOI
  43. [43]Bergé, L.; Chapellier, M.; De Combarieu, M.; Dumoulin, L.; Giuliani, A.; Gros, M.; De Marcillac, P.; Marnieros, S.; Nones, C.; Novati, V.; others. Complete event-by-event α/γ(β) separation in a full-size TeO₂ CUORE bolometer by Neganov-Luke-magnified light detection. Phys. Rev. C 2018, 97, 032501.DOI
  44. [44]Haller, E.E. Advanced far-infrared detectors. Infrared Phys. Techn. 1994, 35, 127.
  45. [45]Andreotti, E.; Brofferio, C.; Faggian, L.; Giuliani, A.; Margesin, B.; Nones, C.; Pedretti, M.; Rusconi, C.; Salvioni, C.; Tenconi, M. Production, characterization and selection of the heating elements for the response stabilization of the CUORE bolometers. Nucl. Instrum. Meth. A 2012, 664, 161.
  46. [46]Alessandrello, A.; Brofferio, C.; Bucci, C.; Cremonesi, O.; Giuliani, A.; Margesin, B.; Nucciotti, A.; Pavan, M.; Pessina, G.; Previtali, E.; others. Methods for response stabilization in bolometers for rare decays. J. Cryst. Growth 1998, 412, 454.DOI
  47. [47]Azzolini, O.; Barrera, M.; Beeman, J.; Bellini, F.; Beretta, M.; Biassoni, M.; Brofferio, C.; Bucci, C.; Canonica, L.; Capelli, S.; others. CUPID-0: the first array of enriched scintillating bolometers for 0νββ decay investigations. Eur. Phys. J. C 2018, 78, 428.DOI
  48. [48]Armatol, A.; Armengaud, E.; Armstrong, W.; Augier, C.; Avignone III, F.; Azzolini, O.; Barabash, A.; Bari, G.; Barresi, A.; Baudin, D.; others. Novel technique for the study of pileup events in cryogenic bolometers. Phys. Rev. C 2021, 104, 015501.DOI
  49. [49]Umicore Germanium substrates. https://eom.umicore.com/en/germanium-solutions/products/germanium-substrates/. Accessed: 2023-04-25.
  50. [50]Mancuso, M.; Beeman, J.; Giuliani, A.; Dumoulin, L.; Olivieri, E.; Pessina, G.; Plantevin, O.; Rusconi, C.; Tenconi, M. An experimental study of antireflective coatings in Ge light detectors for scintillating bolometers. EPJ Web Conf. 2014, 65, 04003.DOI
  51. [51]Olivieri, E.; CROSS collaboration. The new CROSS Cryogenic Underground (C2U) facility: an overview. XXIX International (online) Conference on Neutrino Physics and Astrophysics (Neutrino 2020), June 22 – July 02, 2020, 2020. Poster presented at the XXIX International (online) Conference on Neutrino Physics and Astrophysics (Neutrino 2020), June 22 – July 02, 2020.DOI
  52. [52]Trzaska, W.H.; Slupecki, M.; Bandac, I.; Bayo, A.; Bettini, A.; Bezrukov, L.; Enqvist, T.; Fazliahkhmetov, A.; Ianni, A.; Inzhechik, L.; others. Cosmic-ray muon flux at Canfranc Underground Laboratory. Eur. Phys. J. C 2019, 79, 721.arxiv.org/abs/1902.00868
  53. [53]The Ultra-Quiet Technology. https://cryoconcept.com/product/the-ultra-quiet-technology/. Accessed: 2023-04-25.
  54. [54]Olivieri, E.; Billard, J.; De Jesus, M.; Juillard, A.; Leder, A. Vibrations on pulse tube based Dry Dilution Refrigerators for low noise measurements. Nucl. Instrum. Meth. A 2017, 858, 73.DOI
  55. [55]Khalife, H. CROSS and CUPID-Mo : future strategies and new results in bolometric search for 0νββ. PhD thesis, Université Paris-Saclay, Orsay, France, 2021.DOI
  56. [56]Velázquez, M.; Veber, P.; Moutatouia, M.; De Marcillac, P.; Giuliani, A.; Loaiza, P.; Denux, D.; Decourt, R.; El Hafid, H.; Laubenstein, M.; others. Exploratory growth in the Li₂MoO₄–MoO₃ system for the next crystal generation of heat-scintillation cryogenic bolometers. Solid State Sci. 2017, 65, 41.DOI
  57. [57]Stelian, C.; Velazquez, M.; Veber, P.; Ahmine, A.; Duffar, T.; De Marcillac, P.; Giuliani, A.; Poda, D.; Marnieros, S.; Nones, C.; others. Experimental and numerical investigations of the Czochralski growth of Li₂MoO₄ crystals for heat-scintillation cryogenic bolometers. J. Cryst. Growth 2020, 531, 125385.DOI
  58. [58]Zolotarova, A.; CROSS collaboration. The CROSS experiment: search for 0ν2β decay with surface sensitive bolometers. J. Phys.: Conf. Ser. 2020, 1468, 012147.DOI
  59. [59]Helis, D.L.; Bandac, I.; Barabash, A.; Billard, J.; Chapellier, M.; de Combarieu, M.; Danevich, F.; Dumoulin, L.; Gascon, J.; Giuliani, A.; Kasperovych, D.; others. Neutrinoless double-beta decay searches with enriched ¹¹⁶CdWO₄ scintillating bolometers. J. Low Temp. Phys. 2020, 199, 467.DOI
  60. [60]Helis, D. Searching for neutrinoless double-beta decay with scintillating bolometers. PhD thesis, Université Paris-Saclay, Orsay, France, 2021.DOI
  61. [61]Arnaboldi, C.; Bucci, C.; Campbell, J.; Capelli, S.; Nucciotti, A.; Pavan, M.; Pessina, G.; Pirro, S.; Previtali, E.; Rosenfeld, C.; others. The programmable front-end system for CUORICINO, an array of large-mass bolometers. IEEE Trans. Nucl. Sci. 2002, 49, 2440–2447.
  62. [62]Carniti, P.; Gotti, C.; Pessina, G. High-Resolution Digitization System for the CROSS Experiment. J. Low Temp. Phys. 2020, 199, 833.DOI
  63. [63]Carniti, P.; Gotti, C.; Pessina, G. High resolution filtering and digitization system for cryogenic bolometric detectors. Nucl. Instrum. Meth. A 2023, 1045, 167658.DOI
  64. [64]Novati, V.; Bergé, L.; Dumoulin, L.; Giuliani, A.; Mancuso, M.; de Marcillac, P.; Marnieros, S.; Olivieri, E.; Poda, D.; Tenconi, M.; others. Charge-to-heat transducers exploiting the Neganov-Trofimov-Luke effect for light detection in rare-event searches. Nucl. Instrum. Methods Phys. Res. A 2019, 940, 320–327.
  65. [65]Mancuso, M. Development and optimization of scintillating bolometers and innovative light detectors for the search for neutrinoless double beta decay. PhD thesis, Université Paris-Sud, Orsay, France, 2016.
  66. [66]Gatti, E.; Manfredi, P. Processing the signals from solid-state detectors in elementary-particle physics. Riv. Nuovo Cim. 1986, 9, 1.
  67. [67]Beeman, J.; Bellini, F.; Casali, N.; Cardani, L.; Dafinei, I.; Di Domizio, S.; Ferroni, F.; Gironi, L.; Nagorny, S.; Orio, F.; others. Characterization of bolometric Light Detectors for rare event searches. JINST 2013, 8, P07021.
  68. [68]Pirro, S.; Beeman, J.; Capelli, S.; Pavan, M.; Previtali, E.; Gorla, P. Scintillating double beta decay bolometers. Phys. Atom. Nucl. 2006, 69, 2109.DOI
  69. [69]Piperno, G.; Pirro, S.; Vignati, M. Optimizing the energy threshold of light detectors coupled to luminescent bolometers. JINST 2011, 6, P10005.
  70. [70]Poda, D.V.; CUPID-Mo collaboration. Performance of the CUPID-Mo double-beta decay bolometric experiment. XXIX International (online) Conference on Neutrino Physics and Astrophysics (Neutrino 2020), June 22 – July 02, 2020, 2020. Poster presented at the XXIX International (online) Conference on Neutrino Physics and Astrophysics (Neutrino 2020), June 22 – July 02, 2020.
  71. [71]Armegaud, E.; others. Development and underground test of radiopure ZnMoO₄ scintillating bolometers for the LUMINEU 0ν2β project. JINST 2015, 10, P05007.
  72. [72]Danevich, F.A. Radiopure tungstate and molybdate crystal scintillators for double beta decay experiments. Int. J. Mod. Phys. A 2017, 32, 1743008.
  73. [73]Danevich, F.A.; Tretyak, V.I. Radioactive contamination of scintillators. Int. J. Mod. Phys. A 2018, 33, 1843007.
  74. [74]Feldman, G.J.; Cousins, R.D. Unified approach to the classical statistical analysis of small signals. Phys. Rev. D 1998, 3873, 57.
  75. [75]Barabash, A.S. Precise Half-Life Values for Two-Neutrino Double-β Decay: 2020 Review. Universe 2020, 6, 159.
  76. [76]Augier, C.; Barabash, A.; Bellini, F.; Benato, G.; Beretta, M.; Bergé, L.; Billard, J.; Borovlev, Y.; Cardani, L.; Casali, N.; Cazes, A.; others. The background model of the CUPID-Mo 0νββ experiment. Eur. Phys. J. C (to be submitted) 2023.
  77. [77]Azzolini, O.; Beeman, J.; Bellini, F.; Beretta, M.; Biassoni, M.; Brofferio, C.; Bucci, C.; Capelli, S.; Cardani, L.; Carniti, P.; others. Background model of the CUPID-0 experiment. Eur. Phys. J. C 2019, 79, 583.
  78. [78]Azzolini, O.; Beeman, J.; Bellini, F.; Beretta, M.; Biassoni, M.; Brofferio, C.; Bucci, C.; Capelli, S.; Cardani, L.; others. Final Result on the Neutrinoless Double Beta Decay of ⁸²Se with CUPID-0. Phys. Rev. Lett. 2022, 129, 111801.
  79. [79]Adams, D.; Alduino, C.; Alfonso, K.; Avignone III, F.; Azzolini, O.; Bari, G.; Bellini, F.; Benato, G.; Biassoni, M.; Branca, A.; others. Measurement of the 2νββ Decay Half-Life of ¹³⁰Te with CUORE. Phys. Rev. Lett. 2021, 126, 171801.
  80. [80]Adams, D.; Alduino, C.; Alfonso, K.; Avignone III, F.; Azzolini, O.; Bari, G.; Bellini, F.; Benato, G.; Beretta, M.; Biassoni, M.; others. Search for Majorana neutrinos exploiting millikelvin cryogenics with CUORE. Nature 2022, 604, 53.DOI
  81. [81]der Matoesian, E.; Goldhaber, M. Limits for Lepton-Conserving and Lepton-Nonconserving Double Beta Decay in Ca⁴⁸. Phys. Rev. 1966, 146, 810–815.
  82. [82]Gavrilyuk, Y.M.; Gangapshev, A.M.; Kazalov, V.V.; Kuzminov, V.V.; Panasenko, S.I.; Ratkevich, S.S. Indications of 2ν2K capture in ⁷⁸Kr. Phys. Rev. C 2013, 87, 035501.DOI
  83. [83]Novella, P.; Sorel, M.; Usón, A.; Adams, C.; Almazán, H.; Álvarez, V.; Aparicio, B.; Aranburu, A.; Arazi, L.; Arnquist, I.; others. Measurement of the ¹³⁶Xe two-neutrino double-β-decay half-life via direct background subtraction in NEXT. Phys. Rev. C 2022, 105, 055501.DOI
  84. [84]Giuliani, A.; Poves, A. Neutrinoless Double-Beta Decay. Adv. High Energy Phys. 2012, 2012, 857016.

Paper details

vlnc:W_exjaqtbt
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 9

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents