A high-resolution search for axion dark-matter flows with ORGAN-Q

Abstract

We search for narrow axion dark-matter flows using the high-resolution data acquired during the ORGAN-Q experiment. The analysis covers nine potential axion linewidths from 0.466 ~Hz to 119.209 ~Hz, equivalent to axion effective quality factors 1.3×10101.3\times 10^{10} to 5.2×1075.2\times 10^7, over the range 6.1550 ~GHz to 6.3496 ~GHz, corresponding to axion masses of approximately 25.455 μeV~μ\mathrm{eV} to 26.260 μeV~μ\mathrm{eV}. Once contributions from native-bin correlations, data-quality and interference vetoes, frequency-dependent system noise, the cavity response, and filter attenuation are accounted for, no candidate satisfies the required persistence ratio in any search bandwidth. Across the nine assumed linewidths, the strongest 95%95\% KSVZ axion-flow density limits range from 22.8 GeVcm−3~\mathrm{GeVcm^{-3}} for a 0.466 Hz0.466~\mathrm{Hz} signal to 153.7 GeVcm−3153.7~\mathrm{GeVcm}^{-3} for a 119.209 Hz119.209~\mathrm{Hz} signal, with both attained near ma=25.857 μeVm_a=25.857~μ\mathrm{eV}.

Introduction

The axion was originally introduced as a consequence of the Peccei–Quinn mechanism, which provides a dynamical solution to the strong CP problem of quantum chromodynamics [1, 2, 3]. In addition to this particle-physics motivation, axions produced non-thermally in the early universe can behave as cold dark matter and may constitute some or all of the Galactic dark-matter density [4, 5, 6]. Their small mass and weak interactions make direct detection challenging, but the axion-photon coupling provides a measurable electromagnetic signature.

In a microwave-cavity haloscope, Galactic axions may convert into photons in the presence of a strong static magnetic field [7, 8]. When a cavity mode is tuned near the axion conversion frequency, the deposited power is resonantly enhanced and can be detected through the receiver chain. Conservation of energy relates the frequency νa\nu_a of the resulting photon to the energy of a nonrelativistic axion according to

hνa≃mac2+12mav2(1)h\nu_a \simeq m_a c^2 + \frac{1}{2}m_a v^2 \tag*{(1)}

where hh is Planck’s constant, mam_a is the axion mass, cc is the speed of light, and vv is the axion velocity relative to the detector. For an axion flow with velocity dispersion Δv\Delta v, this relation gives a fractional signal linewidth

Δνaνa,0≃vΔvc2(2)\frac{\Delta\nu_a}{\nu_{a,0}} \simeq\frac{v\Delta v}{c^2} \tag*{(2)}

where Δνa\Delta\nu_a is the signal linewidth, νa,0=mac2/h\nu_{a,0}=m_a c^2/h is the axion rest-mass frequency, and Δv\Delta v is the velocity dispersion of the flow. The central signal frequency therefore

primarily identifies the mass, while the signal linewidth and temporal frequency variation contain information about the local axion velocity distribution.

The Oscillating Resonant Group Axion (ORGAN) experiment is a microwave-cavity haloscope designed primarily to search for axions at comparatively high masses [9]. The ORGAN-Q experiment used a tunable conducting-rod resonator, a strong solenoidal magnetic field, and operated at milli-kelvin with a Josephson parametric amplifier to search the frequency interval from approximately 6.16 GHz to 6.35 GHz. It provided constraints on the virialised axion mass range over 25.45 μ\mueV to 26.27 μ\mueV [10].

Conventional haloscope analyses generally adopt a smooth, approximately virialised Galactic halo, for which characteristic velocities of order 10−3c10^{-3}c produce a fractional axion linewidth of order 10−610^{-6} [10, 11, 12]. At the ORGAN-Q operating frequency, this corresponds to a signal distributed over several kilohertz. However, galactic dark matter may consist of more coherent populations. Fine-grained substructure may produce flows with much smaller velocity dispersions and correspondingly narrower spectral features. Such models include cold infall and caustic ring flows, together with streams produced by the tidal disruption of axion miniclusters [13, 14, 15]. The assumptions of a caustic ring model for example, produce an upper limit to the fractional energy dispersion of the “Big Flow” dark matter stream of δE/(mac2)≲2.4×10−10\delta E/(m_a c^2) \lesssim2.4 \times10^{-10} [14], with δE\delta E the root-mean-square energy dispersion of the flow. This corresponds to a lower limit of effective quality factor Qrms≡mac2/δE≳4×109Q_{\rm rms} \equiv m_a c^2/\delta E \gtrsim4 \times10^9 or an upper limit on linewidth of less than 1.5 Hz at ORGAN-Q frequencies. This model also provides an axion density central estimate of 11.2 GeV/cm3^3 [16], providing a model-dependent benchmark for interpreting limits on narrow flows. High-resolution cavity searches have previously been used to probe such non-virialised axion populations [17, 18, 19, 20].

The ORGAN-Q acquisition system generated two simultaneous data streams: a medium resolution stream, previously used to report on a virialised halo search, and a high-resolution stream, used here to search for narrower signals (see § 2 B for details). Motivated by these possibilities, we use the ORGAN-Q high-resolution data to search for persistent narrow spectral features and constrain the density of non-virialised KSVZ axion flows.

Experiment and Data Set

ORGAN apparatus and operating configuration

The ORGAN-Q experiment [10] employed a 0.708 L oxygen-free high-conductivity copper cavity inside a 7 T solenoidal magnet, for which the average magnetic field over the cavity volume was B0=6.26(1)B_0 = 6.26(1) T. An off-axis aluminium tuning rod varied the frequency of the TM010\mathrm{TM}_{010} mode between approximately 6.15 GHz to 6.35 GHz without encountering a mode crossing, yielding typical mode form factors of C≃0.42C \simeq0.42. Over the rod-tuning range of the experiment, the loaded quality factor was QL≃1700Q_L \simeq1700 (σ=400\sigma= 400), whilst the antenna coupling had an average value of β≃1.45\beta\simeq1.45 (σ=0.32\sigma= 0.32).

The experimental configuration is shown schematically in Figure 1. The cavity and first-stage receiver components operated at millikelvin temperatures. The mixing chamber and cavity were maintained near 80 mK and 100 mK, respectively, although motion of the tuning rod produced a higher characteristic rod temperature of approximately 500 mK [10]. Signals from the strongly coupled cavity port were routed through a cryogenic circulator to a flux-driven Josephson parametric amplifier (JPA), followed by a cryogenic high-electron-mobility-transistor (HEMT) amplifier. The JPA was operated in three-wave-mixing-mode, with a pump frequency near twice the signal frequency, and provided more than 18 dB of gain over most of the searched range. Following amplification, the signal was mixed to an intermediate frequency using an in-phase and quadrature mixer, whose outputs were combined using a 90° hybrid to provide image rejection before digitisation.

Figure 1. Schematic of the ORGAN-Q apparatus and receiver chain used to acquire the high-resolution data. A potential axion signal generated in the tunable cavity is routed through the cryogenic receiver to the flux-driven JPA and subsequent HEMT amplification stage. At room temperature, the amplified signal is down-converted using an image-rejecting mixer before being processed by the FPGA digitiser. The vector network analyser, cryogenic switch and heated load provide the measurements required for a cavity and receiver calibration. Piezoelectric actuators control the tuning-rod position and antenna coupling. The schematic is reproduced from Ref. [10].

At each tuning position, vector-network-analyser measurements tracked the cavity resonance and JPA gain response. The tuning increment was approximately one fifth of the cavity linewidth, and acquisition at an individual tuning position typically lasted between 30 min to 60 min. The medium- and high-resolution data streams were acquired simultaneously by the field-programmable gate array (FPGA) digitiser.

Data acquisition

The medium-resolution stream performed real-time averaging and produced 6554-bin spectra over a 6.25 MHz interval centred near an intermediate frequency of 45 MHz, corresponding to a bin spacing of ≃954\simeq954 Hz. These data also supplied the tuning and receiver calibration metadata used in the present analysis. In parallel, the high-resolution stream operated at one quarter of the primary sampling rate and without real-time spectral averaging. For the high-resolution stream, time-series data were transferred continuously, without gaps, from the FPGA to the host computer, where FFTs were computed to produce the stored power spectra. Each stored high-resolution spectrum contains 3,355,444 bins spanning 1.5625 MHz with frequency spacing δf≃0.466\delta f \simeq0.466 Hz. However, after analysing the data, frequency-bin correlations were detected. These are consistent with rectangular records zero-padded by a representative oversampling factor R≃4.272R \simeq4.272, as discussed and accounted for in Appendix A. This corresponds to a representative record duration Trec=1/(Rδf)≃0.503T_{\rm rec} = 1/(R\delta f) \simeq0.503 s, and a rectangular-window equivalent noise bandwidth 1/Trec≃1.991/T_{\rm rec} \simeq1.99 Hz.

Two passes over the frequency range were acquired from 13–26 February 2024 and 6–10 March 2024. The second pass over selected frequency regions were to provide sufficient coverage after accounting for interference or poor receiver performance.

System-noise calibration

The frequency-dependent system-noise temperature referred to the cavity output Tsys,iT_{\rm sys,i}, was determined using the signal-to-noise ratio improvement (SNRI) procedure discussed in Ref. [10] for each tuning position. This combined the measured HEMT noise temperature and receiver-line attenuation with JPA-off transfer functions measured using a vector network analyser and noise-power spectra recorded using a spectrum analyser. The same Tsys,iT_{\rm sys,i} cuts and calibration employed in the medium-resolution were used for this search, satisfying 0.4 K<Tsys,i<1.35 K0.4\ \mathrm{K} < T_{\rm sys,i} < 1.35\ \mathrm{K}.

Analysis pipeline

Baseline Filtering

Each raw high-resolution spectrum may contain smooth frequency-dependent structure arising from the receiving gain and noise response. This baseline must be estimated and divided out before the statistical properties of the residual power can be tested. Savitzky–Golay (SG) filters are commonly used for this purpose in halo-scope analyses. In the present analysis, the baseline was instead estimated using the modified-sinc (MS) smoother introduced in Ref. [21]. At a matched 3-dB cutoff, the MS filter provides substantially stronger stop-band suppression than a conventional SG filter [21]. The transfer functions of the two filters at a demonstrative window are shown in Figure 2. Despite stronger stop-band suppression, this alone does not establish improved recovery of narrow spectral signals. Such signals have broad Fourier spectra, and their attenuation after baseline normalisation depends on the full filter response and the signal profile. The MS smoother was therefore selected for its strong suppression of fine-scale structure in the estimated baseline, with its signal-recovery evaluated using injection tests described in § 6 B.

Figure 2. Representative magnitude responses of degree-four Savitzky–Golay (SG) and modified-sinc (MS) smoothers matched at their −3-dB cutoff. The responses are normalised at zero spatial frequency, expressed as cycles per native spectral bin. The MS kernel exhibits substantially lower stop-band sidelobes.

Denoting the linear power in native frequency bin ii by PiP_i, the estimated baseline was

b^i=∑j=−mmhjMSPi−j,(3)\hat{b}_i = \sum_{j=-m}^{m} h_j^{MS} P_{i-j}, \tag*{(3)}

where b^i\hat{b}_i is the estimated baseline in bin ii, hjMSh_j^{MS} is the normalised symmetric MS kernel at bin offset jj, and mm is the kernel half-width. The analysis used the degree parameter d=4d = 4 and m=100,000m = 100{,}000, corresponding to a 2m+12m + 1 bin kernel. At the boundaries of each spectrum, the data required by the convolution were extrapolated using cosine-squared-weighted linear extrapolation. The convolution was evaluated using zero-padded FFT convolution to assist with edge-handling.

Bins belonging to manually identified strong-features masks discussed in § 3 E, had their power replaced by the mean power measured ten masked-interval widths either side of the mask. The masked bins were omitted from the Erlang test in § 3 B and excluded from the subsequent trigger search.

Noise Distribution Cuts

Following baseline normalisation, the power distribution of each raw spectrum was tested for consistency with an Erlang distribution;

p(x;k,β)=xk−1e−x/ββk(k−1)!,x≥0,(4)p(x;k,\beta) = \frac{x^{k-1}e^{-x/\beta}}{\beta^k(k-1)!}, \qquad x \ge0, \tag*{(4)}

where xx is the baseline-normalised power, kk is the shape parameter and β\beta is the scale parameter. For an individual, unaveraged spectrum, k=1k = 1 and β\beta is its mean power, reducing Eq. 4 to the exponential distribution expected for stationary Gaussian receiver noise. The evolution of the erlang distribution is shown in Figure 3 and compared to a sample dataset.

Erlang evolution expectation with comparison to the data

Figure 3. Erlang evolution expectation with comparison to the data.

The agreement between the measured distribution of a spectrum and the expected Erlang distribution is quantified using the reduced Pearson’s chi-square statistic [22],

χν2=1ν∑i(Oi−Ei)2Ei,(5)\chi_\nu^2 = \frac{1}{\nu}\sum_i \frac{(O_i-E_i)^2}{E_i}, \tag*{(5)}

where OiO_i and EiE_i are the observed and expected counts in histogram bin ii, respectively, and ν\nu is the degrees of freedom. Every tenth native frequency bin was sampled, known strong signals masked, constructed using 1000 equal-width bins with those Ei<5E_i < 5 excluded. The expected counts were normalised to the corresponding observed total.

To establish the expected variation of the goodness-of-fit statistic for noise-only spectra, we generated 100,000 synthetic spectra with independently exponentially distributed powers. Each was analysed using the same procedure as the experimental data. The resulting distribution of reduced χν2\chi^2_\nu, shown in Figure 4, had a mean and standard deviation of 1.00 and 0.0629, respectively. These values were used to set the data-quality acceptance criteria: 0.622<χν2<1.3780.622 < \chi^2_\nu< 1.378, corresponding to approximately 1±6σχν21 \pm6\sigma_{\chi^2_\nu}. The cut rejected two spectra from the first pass and two from the second-pass out of the eligible tuning folders. The first failures exhibited anomalous background behaviour, while the second failures had substantially elevated χν2\chi^2_\nu values and resembled corrupted start-up records.

Reduced chi-square distribution obtained from 100,000 synthetic Erlang-distributed spectra

Figure 4. Reduced chi-square distribution obtained from 100,000 synthetic Erlang-distributed spectra. The adopted quality cuts are shown by the vertical dotted lines.

Averaging

Within each dataset and cavity tuning, the accepted time-ordered spectra were partitioned into consecutive, non-overlapping groups containing at most 100 spectra, with group sizes made as uniform as possible. This provides an enhancement of signal-to-noise ratio of each group, whilst the conservative probability of a doppler drift of one bin remains low (∼1\sim1 bin width drift per 1000 spectra). Each group was represented by the bin-wise arithmetic mean of its baseline-normalised spectra, maintaining the actual group size NiN_i, which was used in subsequent statistical calculations. This procedure produced 17, 421 and 4361 first and second pass averaged groups, respectively, prior to the subsequent calibration quality and interference vetoes.

Native-bin correlations

The raw FFT powers exhibit correlations between neighbouring native frequency bins. For each dataset, the Pearson correlation coefficient ρl\rho_l between bins was evaluated before MS filtering using 4420 first-pass and 1370 second-pass spectra, and the median was taken across spectra. The correlations are dominated by the first three lags, with ρ1≈0.8\rho_1 \approx0.8 for both datasets. The representative FFT oversampling factor was obtained by jointly fitting the first twelve correlation lags of the first and second-pass datasets to the rectangular-record model derived in Appendix A.

Let qq denote the number of stored frequency bins in the sliding search window. For the mean xˉq=q−1∑j=1qxj\bar{x}_q = q^{-1}\sum_{j=1}^{q}x_j, assuming locally stationary bin statistics with a variance σx2\sigma_x^2, summing the covariance terms gives [23]

Var⁡(xˉq)=σx2q2(q+2∑l=1q−1(q−l)ρl)=σx2qVq(6)\operatorname{Var}(\bar{x}_q) = \frac{\sigma_x^2}{q^2}\left(q + 2\sum_{l=1}^{q-1}(q-l)\rho_l\right) = \frac{\sigma_x^2}{q}V_q \tag*{(6)}

where

Vq=1+2q∑l=1q−1(q−l)ρl.(7)V_q = 1 + \frac{2}{q}\sum_{l=1}^{q-1}(q-l)\rho_l. \tag*{(7)}

Here ll is the integer separation between bins. Averaging NiN_i independent spectra therefore gives variance VqNiq\frac{V_q}{N_iq}. Equating this to the variance 1k\frac{1}{k} of a unit-mean gamma distribution yields an effective shape parameter keff,i=NiqVqk_{\mathrm{eff},i} = \frac{N_iq}{V_q}. For the widest search window, q=256q = 256, the measured values are Vq≈4.1V_q \approx4.1 for both datasets. These correlations were used in subsequent trigger-threshold and sensitivity calculations.

Interference Masks and Vetoes

Four classes of contaminated intermediate-frequency (IF) intervals were catalogued: tuning-specific strong instrumental features, dataset-wide IF lines, tuning-specific radio-frequency interference (RFI), and spectral combs, summarised in Table I.

Each tuning-specific RFI signal was carefully analysed over the duration at which they appeared. The key indication that these were pickup of an instrumental source elsewhere was inferred from its stability on the order of minutes, followed by discontinuous frequency jumps up to 100 Hz.

The strong feature masks were applied before baseline estimation to prevent prominent pump and mixing products from distorting the MS baseline.

For a qq-bin search, each interval was expanded on either side by (q−1)δf2(q-1)\frac{\delta f}{2}, where δf\delta f is the native bin spacing, so that any sliding window intersecting a masked bin was vetoed. All manual, IF, RFI, and comb vetoes were applied before persistence matching, and consequently, vetoed triggers could neither seed nor support a candidate. Additionally, affected groups provide no coverage of that trial frequency.

Multibin trigger catalogues

Each averaged spectrum was searched using bin-aligned top-hat templates formed from sliding means of qq adjacent native bins, evaluated with a one-bin stride. The tested window sizes were q∈{1,2,4,8,16,32,64,128,256}q \in\{1, 2, 4, 8, 16, 32, 64, 128, 256\}, corresponding to bandwidths starting from the native bin spacing δf=0.465661\delta f = 0.465661, up to 119.209 Hz.

For the averaged group ii, a window was recorded as a trigger when its mean power exceeded

xth,i(q)=Γsf−1(e−12;keff,i(q),1keff,i(q)),(8)x_{\mathrm{th},i}(q) = \Gamma_{\mathrm{sf}}^{-1}\left(e^{-12}; k_{\mathrm{eff},i}(q), \frac{1}{k_{\mathrm{eff},i}(q)}\right), \tag*{(8)}

where Γsf,i−1\Gamma_{\mathrm{sf},i}^{-1} is the inverse survival function of the gamma distribution, and keff,ik_{\mathrm{eff},i} is the effective shape parameter defined in Sec. III D. The value e−12e^{-12} provides a manageable number of triggers for processing (∼e−12×3.4×106≈21\sim e^{-12} \times3.4 \times10^6 \approx21 per spectra), whose IF frequency and sliding mean power were stored.

Candidate Selection

An axion flow would produce a narrow excess of microwave power above the receiver-noise background, where the intrinsic linewidth is set by the flow’s velocity dispersion. For the persistent flows we consider here, a dark matter signal should recur in observations covering the same radio-frequency range within allowed relative Doppler drifts of the detector. Candidate signals are therefore identified by testing whether an excess is persistent across temporally-separated measurements within the allowed frequency drift. Candidate selection was performed separately for each search width using the combined first and second-pass trigger catalogues. Only the groups and triggers passing the calibration and interference selections discussed earlier enter this stage.

Doppler-Drift Model

The axion signal present at the detector may drift in frequency due to model-dependent Doppler effects. The axion energy depends on the relative velocity v⃗=v⃗a−v⃗D\vec{v} = \vec{v}_a - \vec{v}_D, where v⃗a\vec{v}_a is the axion flow velocity, and v⃗D\vec{v}_D is the detector velocity, using the galactic coordinate system. The detector velocity is broken up into several components: v⃗D=v⃗⊙+v⃗e+v⃗r\vec{v}_D = \vec{v}_{\odot} + \vec{v}_e + \vec{v}_r. v⃗⊙\vec{v}_{\odot} is the Sun’s total galactocentric velocity, including the contributions of local standard of rest and the solar peculiar orbit, v⃗e\vec{v}_e is the velocity of the Earth around the sun, and v⃗r\vec{v}_r is the velocity of the experiment due to rotation of the Earth in Perth, Australia. The axion frequency is given by Eq. (1). One can treat v⃗a\vec{v}_a and v⃗⊙\vec{v}_{\odot} as constant over the duration of the experiment, and define the axion rest frequency νa,0=mac2h\nu_{a,0} = \frac{m_a c^2}{h}. For two spectra taken at t1t_1 and t2t_2, the predicted frequency change is

Veto classCountReason/Description
Strong instrumental features11Linear combinations of the pump, synth, and/or sampling frequencies result in measured signals.
Dataset-wide IF lines10Approximately fixed IF across cavity tunings, indicating receiver-chain interference.
Tuning-specific RFI2Discontinuous frequency jumps over time, consistent with instrumental pickup.
Spectral combs7Periodic instrumental interference combs with 99 999.5 Hz spacing.

Table 1. Interference vetoes across the data.

Δνa=νa,02c2(v⃗(t2)⋅v⃗(t2)−v⃗(t1)⋅v⃗(t1)),(9)\Delta\nu_a = \frac{\nu_{a,0}}{2c^2}\left(\vec{v}(t_2) \cdot\vec{v}(t_2) - \vec{v}(t_1) \cdot\vec{v}(t_1)\right), \tag*{(9)}

highlighting the time dependence of the relative velocity v⃗(t)\vec{v}(t).

The detector velocity was evaluated by constructing the laboratory barycentric state and transforming it into the Astropy Galactocentric frame. The Earth’s barycentric position and velocity at each spectrum time were obtained from the JPL DE440 ephemeris [24], while the laboratory topocentric velocity due to the Earth’s rotation was calculated at the UWA laboratory position using Astropy’s EarthLocation.get_gcrs_posvel routine [25]. The topocentric GCRS vector is geocentric but oriented consistently with the barycentric celestial axes, so it was combined with the Earth’s barycentric state before transformation to the Galactocentric frame. The Galactocentric transformation used the Astropy default solar parameters, corresponding to v⃗⊙=(12.9,245.6,7.78) km s−1\vec{v}_{\odot} = (12.9, 245.6, 7.78)\ \mathrm{km}\ \mathrm{s}^{-1} [25]. The resulting detector velocity v⃗D(t)\vec{v}_D(t) was used with an assumed axion-flow velocity v⃗a\vec{v}_a to compute the relative velocity v⃗(t)=v⃗a−v⃗D(t)\vec{v}(t) = \vec{v}_a - \vec{v}_D(t), which determines the expected frequency drift between spectra through Eq. (9).

The axion flow speed was fixed at the galactic escape velocity ∣v⃗a∣=vesc=550 km/s|\vec{v}_a| = v_{\mathrm{esc}} = 550\ \mathrm{km}/\mathrm{s} [26, 27] to allow maximal Doppler drift. Its direction was chosen from the two directions parallel and antiparallel to v⃗D(tend)−v⃗D(tstart)\vec{v}_D(t_{\mathrm{end}}) - \vec{v}_D(t_{\mathrm{start}}), retaining the direction that maximised the absolute frequency change between the first and last data timestamps of the experimental run. For a seed trigger at RF frequency fsf_s in group ii and a comparison group jj, Eq. (9) was evaluated between the start of the earlier group and the end of the later group, using fsf_s in place of νa,0\nu_{a,0}. A

trigger at frequency fjf_j was considered persistent when

∣fj−fs∣≤∣Δfij∣+δf,(10)|f_j - f_s| \leq|\Delta f_{ij}| + \delta f, \tag*{(10)}

where Δfij\Delta f_{ij} is the corresponding Doppler displacement and δf\delta f is the native bin spacing.

Persistence Requirement

For each seed trigger ss, Nscan,sN_{\mathrm{scan},s} was the number of eligible averaged groups whose unvetoed RF span contained fsf_s. The corresponding Nmatch,sN_{\mathrm{match},s} counted groups containing at least one same-width trigger satisfying Eq. (10). Each group, including the seed group, contributed at most once. The persistence ratio was therefore

Rpers,s=Nmatch,sNscan,s≥0.3.(11)R_{\mathrm{pers},s} = \frac{N_{\mathrm{match},s}}{N_{\mathrm{scan},s}} \geq0.3. \tag*{(11)}

This is a conservative estimation under the assumption that we expect an incoming axion signal to be persistent at the same frequency within an allowable Doppler drift.

Sensitivity and Density-Limit Construction

Signal and cavity response

For this high-resolution analysis, we constrain the axion-flow density ρa\rho_a with the axion–photon coupling fixed to the KSVZ benchmark. Using the normalisation adopted in Ref. [12], the coupling magnitude is

gKSVZ(f)=0.97απhfΛ2,(12)g_{\mathrm{KSVZ}}(f) = \frac{0.97\alpha}{\pi}\frac{h f}{\Lambda^2}, \tag*{(12)}

where α\alpha is the fine-structure constant and Λ=0.0776 GeV\Lambda= 0.0776\ \mathrm{GeV} is the adopted quantum chromodynamics parameter. The axion rest energy is approximated by hfh f, giving the coupling in GeV−1^{-1}.

For group ii, the expected axion-conversion power at frequency ff and trial flow density ρa\rho_a is [12, 28]

Pa,i(f;ρa)=(gKSVZ(SI))2ρa(J)μ0(hf)2ℏ3c3×(2πfc,i)B02VC,iQL,iβi1+βiLi(f),(13)\begin{aligned} P_{a,i}(f;\rho_a) = \left(g_{\mathrm{KSVZ}}^{(SI)}\right)^2 \frac{\rho_a^{(J)}}{\mu_0(hf)^2}\hbar^3 c^3 \\ &\times(2\pi f_{c,i})B_0^2 V_{C,i}Q_{L,i}\frac{\beta_i}{1+\beta_i}\mathcal{L}_i(f), \tag*{(13)} \end{aligned}

where gKSVZ(J)g_{\mathrm{KSVZ}}^{(J)} is the benchmark coupling evaluated at ff in units of J−1\mathrm{J}^{-1}, and ρa(SI)\rho_a^{(\mathrm{SI})} is the flow density expressed in Jm−3\mathrm{Jm}^{-3}. The Lorentzian cavity response is

Li(f)=11+[2(f−fc,i)/Δfc,i]2.(14)\mathcal{L}_i(f) = \frac{1}{1 + [2(f-f_{c,i})/\Delta f_{c,i}]^2}. \tag*{(14)}

The remaining parameters are the fitted cavity frequency fc,if_{c,i}, cavity full width at half max Δfc,i\Delta f_{c,i}, magnetic field B0B_0, cavity volume VV, interpolated form factor Ci=C(fc,i)C_i = C(f_{c,i}), loaded quality factor QL,iQ_{L,i}, antenna coupling βi\beta_i, hˉ=h/(2π)\bar{h} = h/(2\pi), and vacuum permeability μ0\mu_0.

The signal is modelled by an intrinsic top-hat power spectrum of width W=qδfW = q\delta f, centred on the qq-bin search window. For the assumed top-hat signals, we define the effective axion quality factor as Qa≡νa/WQ_a \equiv\nu_a/W, where WW is the full intrinsic linewidth. The finite record duration broadens this spectrum according to the rectangular-window FFT response. Its expected contribution to the baseline-normalised statistic is

si(f,q;ρa)=ηMS(q)Fq(R)Pa,i(f;ρa)kBTsys,i(f)qδf.(15)s_i(f,q;\rho_a) = \frac{\eta_{\mathrm{MS}}(q)F_q(R)P_{a,i}(f;\rho_a)}{k_BT_{\mathrm{sys},i}(f)q\delta f}. \tag*{(15)}

Here kBk_B is Boltzmann’s constant, Tsys,iT_{\mathrm{sys},i} is the system-noise temperature, ηMS(q)\eta_{\mathrm{MS}}(q) is the MS filter efficiency, and Fq(R)F_q(R) with argument of oversampling factor RR, is the dimensionless signal-response correction due to oversampling that is derived in Appendix A. The quoted signal widths refer to intrinsic linewidths before instrumental broadening. The limits assume that the signal is centred on the search window.

Modified-sinc filter attenuation

For each qq, a weak, unit-area, aligned top-hat was added to a flat baseline, the MS normalisation was applied, and the maximum recovered qq-bin sliding sum was compared with the injected sum. The resulting efficiencies are shown in Table II.

qqqδfq\delta f (Hz)ηMS\eta_{\mathrm{MS}}
10.4660.999 960
20.9310.999 920
41.8630.999 840
83.7250.999 680
167.4510.999 360
3214.9010.998 721
6429.8020.997 441
12859.6050.994 883
256119.2090.989 766

Table II. Modified-sinc filter signal-recovery efficiency for each aligned top-hat search width. The efficiency ηMS\eta_{\mathrm{MS}} is the ratio of recovered to injected qq-bin signal power after baseline normalisation.

Detection probability and 95% limit

Using the correlation-corrected shape parameter keff,ik_{\mathrm{eff},i} and threshold xth,ix_{\mathrm{th},i} defined in § 3, the pipeline represents the signal as an additive shift of the normalised statistic. The probability that a group ii crosses its threshold is

pi(ρa;f,q)=Γsf(xth,i−si(f,q;ρa);keff,i,1keff,i),(16)p_i(\rho_a;f,q) = \Gamma_{\mathrm{sf}}\left(x_{\mathrm{th},i}-s_i(f,q;\rho_a);k_{\mathrm{eff},i},\frac{1}{k_{\mathrm{eff},i}}\right), \tag*{(16)}

where Γsf\Gamma_{\mathrm{sf}} is survival function of a gamma distribution. At each trial frequency ff, and search width qq, let NscanN_{\mathrm{scan}} denote the number of eligible averaged groups covering that frequency. As in [29], groups are treated as independent Bernoulli trials with a trigger probability pip_i, and thus, the total number of triggering groups, MM, follows a Poisson-binomial distribution, calculated by successively convolving pairs (1−pi,pi)(1-p_i,p_i).

For each ff and qq, the 95% KSVZ flow-density limit ρ95(f,q)\rho_{95}(f,q) is obtained numerically by solving

Pr⁡(M≥nreq∣ρa=ρ95)=0.95,(17)\Pr(M \ge n_{\mathrm{req}} \mid\rho_a=\rho_{95}) = 0.95, \tag*{(17)}

where nreq=⌈0.3Nscan⌉n_{\mathrm{req}} = \lceil0.3N_{\mathrm{scan}}\rceil, rounded upwards, accounts for the 30% persistence requirement.

Result and discussion

Data-quality and Candidate Outcomes

The averaged-group data quality cuts are summarised in Table III. Missing-metadata (No meta.) groups correspond to tuning folders that were not included in the eligible medium-resolution analysis and are therefore not used in the high-resolution search. Averaged-groups with suspicious Tsys,iT_{\mathrm{sys},i} values, and missing spectrum analyser files (No cal.) are also excluded (see § 2.C).

Data setAcceptedBad TsysT_{\mathrm{sys}}No meta.No cal.total
First14,2565052,6312917,421
Second3,227850268164,361
Combined17,4831,3552,8994521,782

Table III. Averaged-group calibration status before frequency-dependent interference cuts.

No triggers survive the 30% persistence requirement after calibration and interference vetoes.

KSVZ flow-density limits

Figure 5 presents the nominal 95% KSVZ axion-flow density limits sampled every 1 kHz. Each coloured curve corresponds to a distinct assumed top-hat linewidth. At evaluated points, densities above a curve are excluded for that linewidth; missing points denote no valid post-cut coverage.

Figure 5. 95% KSVZ axion-flow density limits sampled on a 1 kHz grid for the nine aligned top-hat signal widths. At evaluated frequencies, densities above each curve are excluded under the intrinsic top-hat model. The calculation includes MS filter attenuation and the measured native-bin correlation correction.

The strongest 95% limits placed on KSVZ axion-flow density range from 22.8 GeV cm−3^{-3} for a 0.466 Hz signal to 153.7 GeV cm−3^{-3} for a 119.209 Hz signal.

The effect of strong nearby bin correlations on the order of ∼4\sim4 bins manifests as reduced sensitivity particularly to the narrowest few-bin-width searches.

Uncertainty Analysis

Following the uncertainty prescription of Ref. [10], we adopt fractional uncertainties of 11.6% in TsysT_{\rm sys} and 5% in CiC_i. Assuming independence, and holding other experimental parameters as fixed, the signal statistic scales as ρaC/Tsys\rho_a C/T_{\rm sys}. Consequently, the density limit scales as ρ95∝Tsys/C\rho_{95} \propto T_{\rm sys}/C. First-order propagation gives

δρ95ρ95≈(δTsysTsys)2+(δCiCi)2≈12.6%.(18)\frac{\delta\rho_{95}}{\rho_{95}} \approx\sqrt{\left(\frac{\delta T_{\rm sys}}{T_{\rm sys}}\right)^2+\left(\frac{\delta C_i}{C_i}\right)^2} \approx12.6\%. \tag*{(18)}

Interpretation and Comparison

The present search complements the previous ORGAN-Q virialised-halo analysis [10] by testing substantially narrower spectral features within the same mass region. The earlier analysis constrained the axion–photon coupling for an assumed local density. Here, we fix the coupling to the mass-dependent KSVZ benchmark and constrain the density of a persistent axion flow under the signal model described in § 6.

Previous ADMX searches placed limits on nonvirialised axion populations in the 1.98 μ\mueV to 2.17 μ\mueV and 3.3 μ\mueV to 3.69 μ\mueV mass regions, considering different flow velocity dispersions and treatments of Doppler modulation [17, 18, 19]. More recently, Bartram et al. reported frequency-dependent KSVZ flow-density limits of approximately 0.003 GeV/cm3^3 to 0.01 GeV/cm3^3 at 95% confidence across the searched portions of 2.81 μ\mueV to 3.31 μ\mueV [20]. Hipp et al. extended the coverage to 3.3 μ\mueV to 4.2 μ\mueV, reporting KSVZ flow-density limits of approximately 0.004 GeV/cm3^3 in their finest-resolution analysis at 95% confidence. CAPP-12 TB also searched for axions associated with the Sagittarius tidal stream, excluding KSVZ axion densities above approximately 0.025 GeV/cm3^3 over 4.51 μ\mueV to 4.59 μ\mueV at 90% confidence under the adopted stream model [30].

The present work provides complementary constraints at substantially higher axion masses, 25.455 μ\mueV to 26.260 μ\mueV, for nine assumed linewidths between 0.466 Hz and 119.209 Hz. Comparisons between these searches must account for their different signal shapes, velocity dispersions, Doppler treatments, and confidence levels. The benchmark of the “Big Flow” discussed in § 1 is not excluded, with our strongest

density limits presented in this study approximately twice this value. This limit is also roughly 51 times larger than the conventional local-halo density benchmark of 0.45 GeV/cm3^3 [31].

Conclusion

The ORGAN-Q high-resolution data were analysed for persistent narrow axion signals over the mass range 25.455 μ\mueV to 26.260 μ\mueV, using nine assumed linewidths between 0.466 Hz and 119.209 Hz. After calibration and interference vetoes, no candidate satisfies the 30% persistence requirement. Under the assumed signal model and KSVZ axion–photon coupling, we obtain 95% upper limits on the local axion-flow density. The strongest limits are 22.8 GeV/cm3^3 for a 0.466 Hz linewidth, and 153.7 GeV/cm3^3 for a 119.209 Hz linewidth, both obtained near an axion mass of 25.857 μ\mueV.

Future ORGAN experiments will have a better understanding of the acquisition and analysis pipeline, maturing the pipeline to scout for signs of correlations earlier and improving the efficiency of data processing. Additionally, acquisition procedures that minimise the total data stored will be investigated, aiming to implement real-time filtering and threshold triggers.

By probing spectral features substantially narrower than those expected from a virialised halo, this analysis extends the ORGAN-Q experiment to non-virialised axion populations. These density constraints complement the previously reported virialised-halo coupling limits within the same mass range.

Acknowledgments

This work is supported by the Australian Research Council grant CE200100008. Michael T. Hatzon acknowledges support from the Defence Science Centre, an initiative of the State Government of Western Australia, and from The University of Western Australia through the Hackett Postgraduate Research Scholarship. Ben T. McAllister acknowledges support from grant DE250100933.

FFT Response due to Oversampling

For white Gaussian noise sampled by a rectangular window, the correlation between nearby values due to oversampling follows the squared-sinc form derived in Appendix A of Ref. [32]. This is given by

ρℓ≈sinc⁡2(Trecδf)=sinc⁡2(ℓR),(19)\rho_\ell\approx\operatorname{sinc}^{2}(T_{\rm rec}\delta f)=\operatorname{sinc}^{2}\left(\frac{\ell}{R}\right), \tag*{(19)}

where ℓ\ell is the separation in stored bins, R=(Trecδf)−1R=(T_{\rm rec}\delta f)^{-1}, and sinc⁡(x)=sin⁡(πx)πx\operatorname{sinc}(x)=\frac{\sin(\pi x)}{\pi x}.

For a rectangular window of duration TrecT_{\rm rec}, the unit-area spectral response to a monochromatic signal, evaluated at a frequency offset Δf\Delta f from the signal, is

K(Δf)=1Trec∣∫0Trece−2πiΔft dt∣2=Trecsinc⁡2(TrecΔf).(20)K(\Delta f) = \frac{1}{T_{\rm rec}}\left|\int_{0}^{T_{\rm rec}} e^{-2\pi i\Delta f t}\,\mathrm{d}t\right|^{2} = T_{\rm rec}\operatorname{sinc}^{2}(T_{\rm rec}\Delta f). \tag*{(20)}

We note here that ∫−∞∞K(Δf) dΔf=1\int_{-\infty}^{\infty} K(\Delta f)\,\mathrm{d}\Delta f = 1, therefore a monochromatic signal of total power PP has a measured signal PSD of PK(Δf)P K(\Delta f).

Next, we consider the top-hat signal, described by an intrinsic power spectrum that is uniform over the full width WW, with intrinsic PSD

Sintrinsic(νa+ν′)=PLW(ν′).(21)S_{\mathrm{intrinsic}}(\nu_a+\nu')=P L_W(\nu'). \tag*{(21)}

Here νa\nu_a is the central signal frequency, ν′\nu' is the frequency offset from νa\nu_a, and LW(ν′)=1/WL_W(\nu')=1/W for ∣ν′∣≤W/2|\nu'|\le W/2, and zero otherwise. A frequency interval dν′\mathrm{d}\nu' within this band contains mean signal power,

dP=PW dν′.(22)\mathrm{d}P=\frac{P}{W}\,\mathrm{d}\nu'. \tag*{(22)}

At the evaluation frequency f=νa+Δff=\nu_a+\Delta f, the contribution from a component at νa+ν′\nu_a+\nu' is K(Δf−ν′)dPK(\Delta f-\nu')\mathrm{d}P. For the assumed stationary signal with an intrinsic top-hat PSD, the expected measured signal PSD is obtained by convolving the intrinsic PSD with the sampled response KK:

Ssig,T(f)=PW∫−W/2W/2K(Δf−ν′) dν′=PHW(Δf),(23)S_{\mathrm{sig},T}(f)=\frac{P}{W}\int_{-W/2}^{W/2}K(\Delta f-\nu')\,\mathrm{d}\nu' =P H_W(\Delta f), \tag*{(23)}

where HW(Δf)H_W(\Delta f) is the top-hat shape after the instrumental response, with contributions added in mean power.

For a signal centred on a qq-bin window, the frequency bin offsets are

Δfj=(j−q−12)δf,j=0,…,q−1.(24)\Delta f_j=\left(j-\frac{q-1}{2}\right)\delta f,\qquad j=0,\ldots,q-1. \tag*{(24)}

Denoting the local noise PSD as S0=kBTsysS_0=k_{\mathrm{B}}T_{\mathrm{sys}} for Boltzmann’s constant kBk_{\mathrm{B}} and system temperature TsysT_{\mathrm{sys}}, before any filter attenuation the expected excess above the unit baseline of the normalised qq-bin mean is

sq=PqS0∑j=0q−1HW(Δfj)=PFqqS0δf.(25)s_q=\frac{P}{qS_0}\sum_{j=0}^{q-1}H_W(\Delta f_j) =\frac{P F_q}{qS_0\delta f}. \tag*{(25)}

which defines the dimensionless response factor

Fq=δf∑j=0q−1HW(Δfj).(26)F_q=\delta f\sum_{j=0}^{q-1}H_W(\Delta f_j). \tag*{(26)}

For the adopted intrinsic width W=qδfW=q\delta f, define

uj=j−q−12R,aq=q2R.(27)u_j=\frac{j-\frac{q-1}{2}}{R},\qquad a_q=\frac{q}{2R}. \tag*{(27)}

Substituting Eqs. (20) and (23) into Eq. (26), and changing the integration variables gives

Fq(R)=−1q∑j=0q−1∫uj+aquj−aqsinc⁡2(u) du.(28)F_q(R)=-\frac{1}{q}\sum_{j=0}^{q-1}\int_{u_j+a_q}^{u_j-a_q}\operatorname{sinc}^2(u)\,\mathrm{d}u. \tag*{(28)}

Evaluating the integral where

J(u)=Si⁡(2πu)π−usinc⁡2(u),(29)J(u)=\frac{\operatorname{Si}(2\pi u)}{\pi}-u\operatorname{sinc}^2(u), \tag*{(29)}

is an anti-derivative of sinc⁡2(u)\operatorname{sinc}^2(u), and

Si⁡(u)=∫0usin⁡tt dt,(30)\operatorname{Si}(u)=\int_0^u\frac{\sin t}{t}\,\mathrm{d}t, \tag*{(30)}

yields the final form of the implemented response factor:

Fq=1q∑j=0q−1[J(uj+aq)−J(uj−aq)].(31)F_q=\frac{1}{q}\sum_{j=0}^{q-1}\left[J(u_j+a_q)-J(u_j-a_q)\right]. \tag*{(31)}

For the measured value of RR, representative factors are F1≈0.23F_1\approx0.23, F4≈0.64F_4\approx0.64, and F256≈0.99F_{256}\approx0.99.

At fixed axion–photon coupling, the conversion power is proportional to the flow density. Consequently, a smaller signal response requires a larger density to produce the same expected excess.

The combined signal response is modelled by the factorised approximation ηMS(q)Fq(R)\eta_{MS}(q)F_q(R), using MS filter efficiencies obtained for unbroadened top-hat profiles. The correlated-noise variance is treated specifically using the measured frequency-bin correlations.

References

  1. [1]R. D. Peccei and H. R. Quinn, Physical Review Letters 38, 1440 (1977).
  2. [2]S. Weinberg, Physical Review Letters 40, 223 (1978).
  3. [3]F. Wilczek, Physical Review Letters 40, 279 (1978).
  4. [4]J. Preskill, M. B. Wise, and F. Wilczek, Physics Letters B 120, 127 (1983).
  5. [5]L. F. Abbott and P. Sikivie, Physics Letters B 120, 133 (1983).
  6. [6]M. Dine and W. Fischler, Physics Letters B 120, 137 (1983).
  7. [7]P. Sikivie, Phys. Rev. Lett. 51, 1415 (1983).
  8. [8]P. Sikivie, Physical Review D 32, 2988 (1985).
  9. [9]B. T. McAllister, G. Flower, E. N. Ivanov, M. Goryachev, J. Bourhill, and M. E. Tobar, Physics of the dark universe 18, 67 (2017).
  10. [10]A. P. Quiskamp, G. R. Flower, S. Samuels, B. T. McAllister, P. Altin, E. N. Ivanov, M. Goryachev, and M. E. Tobar, Physical Review D 111, 095007 (2025).
  11. [11]M. S. Turner, Phys. Rev. D 42, 375 (1990).
  12. [12]B. M. Brubaker, L. Zhong, S. K. Lamoreaux, K. W. Lehnert, and K. A. van Bibber, Phys. Rev. D 96, 123008 (2017).
  13. [13]P. Sikivie, Physics Letters B 432, 139 (1998).
  14. [14]N. Banik and P. Sikivie, Phys. Rev. D 93, 103509 (2016).
  15. [15]P. Tinyakov, I. Tkachev, and K. Zioutas, Journal of Cosmology and Astroparticle Physics 2016 (01), 035.
  16. [16]S. S. Chakrabarty, Y. Han, A. H. Gonzalez, and P. Sikivie, Physics of the Dark Universe 33, 100838 (2021).
  17. [17]L. D. Duffy, P. Sikivie, D. B. Tanner, S. J. Asztalos, C. Hagmann, D. Kinion, L. J. Rosenberg, K. van Bibber, D. B. Yu, and R. F. Bradley, Phys. Rev. D 74, 012006 (2006).
  18. [18]J. Hoskins, J. Hwang, C. Martin, P. Sikivie, N. S. Sullivan, D. B. Tanner, M. Hotz, L. J. Rosenberg, G. Rybka, A. Wagner, S. J. Asztalos, G. Carosi, C. Hagmann, D. Kinion, K. van Bibber, R. Bradley, and J. Clarke, Phys. Rev. D 84, 121302(R) (2011).
  19. [19]J. Hoskins, N. Crisosto, J. Gleason, P. Sikivie, I. Stern, N. S. Sullivan, D. B. Tanner, C. Boutan, M. Hotz, R. Khatriwada, D. Lyapustin, A. Malagon, R. Ottens, L. J. Rosenberg, G. Rybka, J. Sloan, A. Wagner, D. Will, G. Carosi, D. Carter, L. D. Duffy, R. Bradley, J. Clarke, S. O’Kelley, K. van Bibber, and E. J. Daw, Phys. Rev. D 94, 082001 (2016).
  20. [20]C. Bartram, T. Braine, R. Cervantes, N. Crisosto, N. Du, C. Goodman, M. G. Guzzetti, C. Harnett, S. Lee, G. Leum, L. J. Rosenberg, G. Rybka, J. S. W. Dishaw, M. H. Awida, D. Bowring, A. S. Chou, M. Hollister, S. Knirck, A. Sonnenschein, W. Wester, R. Khatiwada, J. Brodsky, G. Carosi, L. D. Duffy, M. Goryachev, B. McAllister, A. Quiskamp, C. Thomson, M. E. Tobar, C. Boutan, M. Jones, B. H. LaRocque, E. Lentz, N. E. Man, N. S. Oblath, M. S. Taubman, J. Yang, J. Clarke, I. Siddiqi, A. Agrawal, A. V. Dixit, J. R. Gleason, Y. Han, A. T. Hipp, S. Jois, P. Sikivie, N. S. Sullivan, D. B. Tanner, E. J. Daw, M. G. Perry, J. H. Buckley, C. Gaikwad, J. Hoffman, K. W. Murch, and J. Russell (ADMX Collaboration), Phys. Rev. D 109, 083014 (2024).
  21. [21]M. Schmid, D. Rath, and U. Diebold, ACS Measurement Science Au 2, 185 (2022).
  22. [22]K. Pearson, The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science 50, 157 (1900).
  23. [23]H. Flyvbjerg and H. G. Petersen, The Journal of Chem- R. S. Park, W. M. Folkner, J. G. Williams, and D. H. Boggs, The Astronomical Journal 161, 105 (2021).
  24. [25]Astropy Collaboration, A. M. Price-Whelan, P. L. Lim, N. Earl, N. Starkman, L. Brad ley, D. L. Shupe, A. A. Patil, L. Corrales, C. E. Brasseur, M. Nöthe, A. Donath, E. Tollerud, B. M. Morris, A. Ginsburg, E. Vaher, B. A. Weaver, J. Tocknell, W. Jamieson, M. H. van Kerkwijk, T. P. Robitaille, B. Merry, M. Bachetti, H. M. Günther, T. L. Aldcroft, J. A. Alvarado-Montes, A. M. Archibald, A. Bödi, S. Bapat, G. Barentsen, J. Bazán, M. Biswas, M. Boquien, D. J. Burke, D. Cara, M. Cara, K. E. Conroy, S. Conseil, M. W. Craig, R. M. Cross, K. L. Cruz, F. D’Eugenio, N. Dencheva, H. A. R. Devillepoix, J. P. Dietrich, A. D. Eigenbrot, T. Erben, L. Ferreira, D. Foreman-Mackey, R. Fox, N. Freij, S. Garg, R. Geda, L. Glattly, Y. Gondhalekar, K. D. Gordon, D. Grant, P. Greenfield, A. M. Groener, S. Guest, S. Gurovich, R. Handberg, A. Hart, Z. Hatfield-Dodds, D. Homeier, G. Hossainzadeh, T. Jenness, C. K. Jones, P. Joseph, J. B. Kallmbach, E. Karamehmetoglu, M. Kaluszyński, M. S. P. Kelley, N. Kern, W. E. Kerzendorf, E. W. Koch, S. Kulumani, A. Lee, C. Ly, Z. Ma, C. MacBride, J. M. Maljaars, D. Muna, N. A. Murphy, H. Norman, R. O’Steen, K. A. Oman, C. Pacifici, S. Pascual, J. Pascual-Granado, R. R. Patil, G. I. Perren, T. E. Pickering, T. Rastogi, B. R. Roulston, D. F. Ryan, E. S. Rykoff, J. Sabater, P. Sakurikar, J. Salgado, A. Sanghi, N. Saunders, V. Savchenko, L. Schwardt, M. Seifert-Eckert, A. Y. Shih, A. S. Jain, G. Shukla, J. Sick, C. Simpson, S. Singanamalla, L. P. Singer, J. Singhal, M. Sinha, B. M. Sipőcz, L. R. Spitler, D. Stansby, O. Streicher, J. Šumak, J. D. Swinbank, D. S. Taranu, N. Tewary, G. R. Tremblay, M. de Val-Borro, S. J. Van Kooten, Z. Vassović, S. Verma, J. V. de Miranda Cardoso, P. K. G. Williams, T. J. Wilson, B. Winkel, W. M. Wood-Vasey, R. Xue, P. Yoachim, C. Zhang, A. Zonca, and Astropy Project Contributors, Astrophysics. J. 935, 167 (2022), arXiv:2206.14220 [astro-ph.IM].
  25. [26]H. H. Koppelman and A. Helmi, Astronomy & Astrophysics 649, A136 (2021).
  26. [27]L. Necib and T. Lin, The Astrophysical Journal 926, 189 (2022).
  27. [28]S. Al Kenany, M. Anil, K. Backes, B. Brubaker, S. Cahn, G. Carosi, Y. Gurevich, W. Kindel, S. Lamoreaux, K. Lehnert, S. Lewis, M. Malnou, D. Palken, N. Rapidis, J. Root, M. Simanovskaia, T. Shokair, I. Urdinaran, K. van Bibber, and L. Zhong, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 854, 11 (2017).
  28. [29]A. Hipp, A. Quiskamp, T. Caligiure, J. Gleason, Y. Han, S. Jois, P. Sikivie, M. Solano, N. Sullivan, D. Tanner, et al., Physical Review D 112, L101101 (2025).
  29. [30]A. K. Yi, S. Ahn, Ç. Kutlu, J. Kim, B. R. Ko, B. I. Ivanov, H. Byun, A. F. van Loo, S. Park, J. Jeong, O. Kwon, Y. Nakamura, S. V. Uchikhin, J. Choi, S. Lee, M. Lee, Y. C. Shin, J. Kim, D. Lee, D. Ahn, S. Bae, J. Lee, Y. Kim, V. Gkika, K. W. Lee, S. Oh, T. Seong, D. Kim, W. Chung, A. Matlashov, S. Youn, and Y. K. Semertzidis, Phys. Rev. D 108, L021304 (2023).
  30. [31]J. I. Read, Journal of Physics G: Nuclear and Particle Physics 41, 063101 (2014).
  31. [32]C. Koen, Monthly Notices of the Royal Astronomical Society 449, 1098 (2015), https://academic.oup.com/mnras/article-pdf/449/1/1098/4138927/stv288.pdf.

Paper details

vlnc:W_ezpyzdtq
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 8

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents