betaFeedback

WorksPhysics and Astronomy

Ratchet based ion pumps for selective ion separations

Abstract

The development of a selective, membrane-based ion separation technology may prove useful in a wide range of applications such as water treatment, battery recycling, ion specific chemical sensors, extraction of valuable metals from sea water, and bio-medical devices. In this work we show that a flashing ratchet mechanism can be used for high precision ion separation. The suggested ratchet-based ion pumps utilize a unique feature of ratchets, the frequency dependent current reversals, to drive ions with the same charge but different diffusion coefficients in opposite directions. We show that for the prevalent ions in water, ions with a relative diffusion coefficient difference as small as 1% can be separated by driving them in opposite directions with a velocity difference as high as 1.2 mm/s. Since the pumping properties of the ratchet are determined by an electric input signal, the proposed ion pumps can pave the way for simple large-scale, fit-to-purpose selective ion separation systems.

Introduction

In recent years there has been a growing demand for membranes capable of extracting a single solute form water.[1, 2, 3] The introduction of an ion selective separation technology can drive a dramatic progress in a range of applications such as water treatment, resource extraction from sea water, bio memetic systems, and chemical sensors. For example, according to the world health organization, the acceptable concentration of lead in drinking water is in the order of several particles per billion[4] and the concentration of NaCl in drinking water is slightly lower than one particle per thousand. Thus, a water decontamination system based on driving ions through a medium with a solute dependent permeability, should be about six orders of magnitudes more permeable to lead than towards sodium ions.

One of the main approaches pursued for solute-solute selective separation is filtration with sub-nanometer pore membranes. In these membranes, the pore diameter is engineered to be between the diameter of the hydrated target ion and its diameter when it is partially dehydrated. Ion transport through the membrane is achieved by applying energy to partially (or fully) dehydrate ions and transport them through the membrane. Selectivity originates from the difference in the hydration energy between ions and the difference in their transport properties within the pores.[1, 2] Although achieving some success, highly selective separation of same-charge ions remains a fundamental challenge.[1, 2] Furthermore, since these membranes rely on functionalized pores with a precise diameter below 1 nm, upscaling these membranes is a great challenge. Moreover, as the membrane selectivity is derived by the pore geometry and chemistry, unique membranes must be designed for every target ion.[2] Another approach for monovalent ion separation is based on the diffusion coefficient dependent response of ions to a pressure induced steaming potential.[1, 5, 6, 7, 8, 9] However, only a few studies have demonstrated this mechanism and so far their reported selectivity was limited. A separation system that can transport ions with the same charge in opposite directions might be able to bypass the limitations faced by current approaches.

Here we propose to use a ratchet mechanism to separate ions with the same charge number according to their diffusion coefficients. Since the selectivity is controlled by the ratcheting process, there is no need for energy intensive ion dehydration and complex sub-nanometer porous structures. Ratchet based separation harnesses a unique characteristic of ratchets to drive particles of different diffusion coefficients in opposite directions, even when having the same charge. This ability paves the way towards removal of solutes found in trace levels in mixtures, which is a fundamental challenge in ions separations. Furthermore, since the separation properties are controlled by an electrical input signal, ratchet-based separation may pave the way to simple fit-to-purpose and real-time applications.

Electronic flashing ratchets are non-equilibrium devices that utilize modulation of a spatially asymmetric electric field to drive a steady state particle flux.[10, 11, 12] Similar to a MOSFET transistor, most of the demonstrated flashing ratchets are comprised of gating electrodes that generate a modulated electric field, and source and drain electrodes between which the ratchet output current flows. The symmetry breaking required to produce a directed current is achieved by structuring the gating electrodes,[13, 14, 15, 16, 17] introducing a nonlinear, diode like conductance between the source and drain,[18, 19] or by applying different signals to different sets of gating electrodes.[20, 21, 22, 23, 24, 25, 26] Figure 1a shows a schematic illustration of the operating principles of a flashing ratchet driving positive charge.[13, 27] The empty circles represent the ions position at the beginning of every step, and the filled circles represent their position at the end of every step. The potential distribution through the device (VV, solid blue line) is switched between two saw-tooth potential distributions V+V^{+} and V−V^{-} where V−=αV+V^{-} = \alpha V^{+}, and the potential asymmetry factor α\alpha is negative. Initially the particles rest at the potential minima, for example at x1x_{1}. When the potential is switched to V−V^{-} at t=t0t=t_{0}, the particles drift in both directions. The length of the time interval between t0t_{0} and t1t_{1} is tuned to allow some drifting particles to reach the potential minimum on their right, x1′x_{1}^{\prime}, but not the potential minimum to their left, x0′x_{0}^{\prime}. Hence, when the potential is switched to V+V^{+} at t=t1t=t_{1}, some of the particles at x1′x_{1}^{\prime} drift further to the right towards x2x_{2}, but all the other particles return to their initial position at x1x_{1} resulting in a net current to the right. The asymmetric potential distribution allows some particles to reach the potential minima in one direction before particles drifting in the opposite direction, thus making it essential for a non-zero net current. Figure 1b illustrates the operation of the same ratchet driving negatively charged particles. Here particles drift towards the potential peaks and as a result, the same potential distribution and input signal generate a net particle flux in the opposite direction.

Figure 1. the operating principles of a flashing ratchet driving positively and negatively charged particles (a and b respectively). The solid blue line illustrates the potential distribution during sequential steps, empty circles mark the position of particles at the beginning of every step and filled circles mark their position at the end of every step.

While in most prior studies flashing ratchets were used to drive electrons or holes in semiconductors,[13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26] the application of flashing ratchets for ion pumping was only suggested recently. Membranes with oscillating pores for resonant osmosis were theoretically analyzed in terms of ratchet transport[28, 29] and nanofluidic charge coupled devices, which can be viewed as reversible ratchets,[30] were studied for DNA separations.[31] In prior work, we have utilized these ratcheting principles to demonstrate experimentally a first-of-its-kind ratchet-based ion pump.[28, 29, 31, 32] In all analyses of ratchet based ion pumps (RBIPs) for ion separation,[28, 29, 31] selectivity is achieved by transporting particles with different velocities according to their diffusion coefficients. However, driving charged particles in the same direction but different velocities meet the same selectivity limitations discussed above when attempting to remove trace concentrations of the target ion from a mixture.

An important hallmark of ratchets is the ability to invert the direction of particle flow with a change in the input signal frequency.[13, 33] The stopping frequency, which is the input signal frequency at which the particle flux changes its direction, is determined by the potential distribution and particles transport properties.[34, 35, 36] As a result, for a given ratchet, there can be a frequency at which particles with the same charge but different diffusion coefficients are transported in opposite directions. This effect was used to sort gold nanoparticles of different sizes and shapes[35, 36, 37] and was studied theoretically in ratchets based on pulsating the spacing between the walls of asymmetric periodic channels or their relative position.[38, 39, 40, 41, 42] This concept was never applied to ion separations. Here we show that by utilizing velocity reversal in ratchet systems, ions with the same charge can be driven in opposite directions according to their diffusion coefficients. This enables extraction of ions with extremely low relative concentrations if their diffusion coefficient is even slightly different from the main ions in the solution. Since the direction of ion transport is determined by the input signal frequency, the sorting properties of the ions can be tuned in real time providing a simple fit-to-purpose solution for a variety of ion separations applications.

Analysis

In the absence of bulk chemical reactions, the transport of noninteracting ions in a solution is determined by the continuity equation:

∂C(x,t)∂t=−∂∂xN(x,t)(1)\frac{\partial C(x,t)}{\partial t}=-\frac{\partial}{\partial x}N(x,t) \tag*{(1)}

where C(x,t)C(x,t) is the ion concentration, and N(x,t)N(x,t) is the ion flux. When convection is negligible, the ion flux is driven by drift and diffusion processes:

N(x,t)=−D[zβC(x,t)∂∂xU(x,t)+∂∂xC(x,t)](2)N(x,t)=-D\left[z\beta C(x,t)\frac{\partial}{\partial x}U(x,t)+\frac{\partial}{\partial x}C(x,t)\right] \tag*{(2)}

Here DD is the ion diffusion coefficient, zz is the ion charge number, β=e/kBTr\beta=e/k_{\mathrm{B}}T_{\mathrm{r}} is the inverse thermal voltage, kBk_{\mathrm{B}} is the Boltzmann constant, TrT_{\mathrm{r}} is the temperature, and ee is the elementary charge. The potential distribution in the system U(x,t)U(x,t) is described as the product of spatial and temporal components:

U(x,t)=V(x)g(t)(3)U(x,t)=V(x)g(t) \tag*{(3)}

We address in this paper a simple ratchet system that has an infinitely periodic sawtooth distribution in space, with a spatial period LL, and is driven by a periodic square wave signal at frequency ff. The spatial and temporal contributions are shown in Figure 2, and are mathematically described by:

Spatial and temporal components of the potential distribution

Figure 2. The spatial and temporal components of the potential distribution

V(x)={Vmax⁡x/Lxc,0<xL<xcVmax⁡1−x/L1−xc,xc<xL<1;g(t)={1,0<t<δ⋅Tα,δ⋅T<t<T(4)\begin{aligned} V(x)&=\begin{cases} V_{\max}\dfrac{x/L}{x_{\mathrm{c}}},&0<\dfrac{x}{L}<x_{\mathrm{c}}\\ V_{\max}\dfrac{1-x/L}{1-x_{\mathrm{c}}},&x_{\mathrm{c}}<\dfrac{x}{L}<1 \end{cases} \qquad;&g(t)=\begin{cases} 1,&0<t<\delta\cdot T\\ \alpha,&\delta\cdot T<t<T \end{cases} \tag*{(4)} \end{aligned}

Where Vmax⁡V_{\max} is the maximum potential amplitude, and xcx_{\mathrm{c}} is the relative length of the first linear section of the sawtooth potential. The temporal modulation g(t)g(t) is described by a duty-cycle δ=t+/T\delta=t^{+}/T, which is the ratio between the time-duration of the 1st step, where the potential is at its maximum value, to the total period T(=1/f)T(=1/f). Each time-period is completed with a 2nd step, in which the sawtooth distribution is multiplied by a potential symmetry factor in the range −1≤α≤0-1\leq\alpha\leq0.

The continuity equation was solved numerically using COMSOL® Multiphysics v5.5. The model domain is x∈[0,L]x\in[0,L], with a periodic boundary condition defined as C(0,t)=C(L,t)C(0,t)=C(L,t), and a normalization condition for the total concentration ∫0Lc(x,t) dx/L=c0\int_{0}^{L}c(x,t)\,dx/L=c_{0}, where c0c_{0} is a reference ion concentration. The time-dependent simulation runs over several consecutive temporal periods, until the net ion flux reaches its steady state value, and the ratchet operation is independent of its initial condition. We define the time τ=0\tau=0 to be the time at which the system enters its steady state. Thus, the ratchet steady state operation is studied by analyzing the interval 0<τ<T0<\tau<T. Our analysis is presented in terms of ion velocity (and not flux), since it is independent of the reference concentration, and therefore is a more general characteristic of the ratchet. We define the instantaneous mean ion velocity, v‾(τ)\overline{v}(\tau), and the net ion velocity, vnetv_{\mathrm{net}}, to be the average velocity in space and time, respectively:

vˉ(τ)=1c0L∫0LN(x,τ) dx(5)\bar{v}(\tau) = \frac{1}{c_0L}\int_{0}^{L} N(x,\tau)\,\mathrm{d}x \tag*{(5)}
vnet=1T∫0Tvˉ(τ) dτ(6)v_{\mathrm{net}} = \frac{1}{T}\int_{0}^{T}\bar{v}(\tau)\,\mathrm{d}\tau \tag*{(6)}

The model predictions were verified by comparing them to prior analytical results under similar conditions.[13, 27] More information on the model validation can be found in the SI.

Results

Velocity reversal

Ratchets can be useful for many applications, but of particular interest to us is to examine the range of parameters that drive ions with the same charge (polarity and valence), in opposite directions. The ion response to a ratchet drive was found by calculating the net ion velocity, vnetv_{\mathrm{net}}, according to eq. (5)-(6) for various input signals, g(t)g(t), potential distributions, V(x)V(x), and ions with diffusion coefficients, DD. Unless stated otherwise, the baseline ratchet parameters that are used in the analysis are: L=1 μmL = 1\ \mu\mathrm{m}, xc=0.7x_c = 0.7, Vmax⁡=2.5 VV_{\max} = 2.5\ \mathrm{V}, β=39.59 V−1\beta= 39.59\ \mathrm{V}^{-1}, δ=0.25\delta= 0.25, α=−0.5\alpha= -0.5, and the ion charge number is z=1z = 1. Figure 3 illustrates a typical velocity reversal example. The figure shows the net ion velocity as a function of the ratchet signal frequency for two ions with different diffusion coefficients. For input signal frequencies between 62–103 kHz, the low DD ions have a positive net velocity, and the high DD ions have a negative net velocity.

Net velocity of two positively charged monovalent ions as a function of input signal frequency

Figure 3. The net velocity of two positively charged monovalent ions (z=1z = 1), as a function of the input signal frequency. In the shaded region the ions move in opposite directions. The ratchet parameters are: L=1 μmL = 1\ \mu\mathrm{m}, xc=0.7x_c = 0.7, Vmax⁡=2.5 VV_{\max} = 2.5\ \mathrm{V}, δ=0.25\delta= 0.25, α=−0.5\alpha= -0.5.

The ion distribution is shown in Figure 4 at a few key times along a cycle, and at a frequency of 83 kHz, corresponding to the largest difference in velocities in Figure 3. Figure 4a describes the evolution of the low DD ions and Figure 4b describes the evolution of the high DD ions. Starting from τ=0\tau= 0, we see that the entire ion population is crowded around the potential minima. After the 1{sup}st switch (from negative to positive potential) at $\tau = 0.02T$, the ion population is split into two groups drifting in opposite directions. By the time of the 2{sup}nd potential switch (from positive to negative potential) at τ=0.25T\tau= 0.25T, nearly all the high DD ions (Figure 4b) have reached the new potential minima, while the majority of the low DD ions (Figure 4a) have not. After the 2{sup}nd switch, at $\tau = 0.26T$, the ions split again, but since the electric fields are lower ($\alpha = -0.5$), the groups drift apart more slowly. This allows more ions to diffuse over the potential peak and join the ions drifting in the negative $x$ direction. When the groups are completely separated, at $\tau = 0.28T$, this process stops. The overall effect is a transfer of ions from the low field side of the sawtooth to the high field side. We call this the *injection* phenomenon. For the high $D$ ions ({xref}Figure 4b), the injection from right to left is the main reason for the net negative velocity: after the 1{sup}st switch 57% are traveling to the left, while after the 2{sup}nd switch only 45% return to the right. Hence, in every time-period, about 12% of the ions are moving one spatial period to the negative direction, resulting in a net velocity of $\bar{v} = -12\% \cdot L/T = -1\ \mathrm{cm/s}$. For the low $D$ ions ({xref}Figure 4a) however, there is a large group that does not reach the potential minimum before the 2{sup}nd switch, that is joined by a smaller group after the 2{sup}nd switch, to travel back right. Overall, 75% of the ions are returning to the right ($\tau = 0.28T$), compared to 60% that traveled left after the 1{sup}st switch (τ=0.02T\tau= 0.02T), resulting in a net velocity of about vˉ=15%⋅L/T=1.25 cm/s\bar{v} = 15\% \cdot L/T = 1.25\ \mathrm{cm/s}. We note that injection also occurs with the low DD ions near the potential maxima after the 2{sup}nd` switch (τ=0.26T\tau= 0.26T), but since only a minority of the ions have reached there, this injection is much less significant. At τ=0.5T\tau= 0.5T, the ions that travelled in the high field side of the sawtooth reach the potential minima; and by the end of the cycle, all the ions reach potential minima, and a new cycle starts.

Concentration response of two positively charged monovalent ions

Figure 4. The concentration response C(x,t)C(x,t) of two positively charged monovalent ions (z=1z = 1) with diffusivities D=1.2⋅10−5 cm2/sD = 1.2 \cdot10^{-5}\,\mathrm{cm}^{2}/\mathrm{s} (a), and D=2⋅10−5 cm2/sD = 2 \cdot10^{-5}\,\mathrm{cm}^{2}/\mathrm{s} (b). The ratchet characteristics are presented in Figure 3, and the frequency is f=83kHzf = 83\mathrm{kHz}. The right axis in both graphs shows also the sawtooth potential distribution U(x,t)U(x,t).

Figure 5 shows a 2D map of the net velocity of monovalent cations as a function of diffusion coefficient and the input signal frequency. All other ratchet ratchet parameters are as in Figure 3 – Figure 4. It can be easily noticed that the stopping frequency, which is the frequency at which the net velocity is zero, increases with the diffusion coefficient. This implies that for a given frequency, ions with diffusion coefficients above a specific value have a positive velocity, and ions with diffusion coefficients below that value travel in the opposite direction. For example, at a frequency of 60 kHz, K+K^{+} and Na+\mathrm{Na}^{+} (D=1.96⋅10−5D = 1.96 \cdot10^{-5} and D=1.33⋅10−5 cm2/sD = 1.33 \cdot10^{-5}\,\mathrm{cm}^{2}/\mathrm{s} respectively) travel backward with velocities of about −0.8-0.8 and −0.5 cm/s-0.5\,\mathrm{cm}/\mathrm{s} respectively, but Li+\mathrm{Li}^{+} (D=1.03⋅10−5 cm2/sD = 1.03 \cdot10^{-5}\,\mathrm{cm}^{2}/\mathrm{s}) travels forwards at a velocity of +0.6 cm/s+0.6\,\mathrm{cm}/\mathrm{s}. This demonstrates the ability of ratchets to separate ions by driving them in opposite directions according to their diffusion coefficients. Moreover, since the input signal determines which ions move forward and which move backward, the ionic selectivity of these ratchets can be tuned in real time.

Net velocity of monovalent cations as a function of the input signal frequency and ion diffusion coefficient

Figure 5. Net velocity of monovalent cations as a function of the input signal frequency and ion diffusion coefficient. All potential and signal parameters are the same as in Figure 3 Figure 4.

To analyze the ratchet behavior for a wide range of ratchet parameters, it is useful to normalize the net ion velocity and the signal's frequency by a characteristic ion velocity parameter v0=zDβVmax⁡/Lv_0 = zD\beta V_{\max}/L and a characteristic ratchet frequency f0=v0/Lf_0 = v_0/L, [33] respectively. For convenience, a normalized frequency parameter Γ=f/f0\Gamma= f/f_0 was also defined. Figure 6a shows the normalized net ion velocity as a function of Γ\Gamma with different symmetry factors α\alpha. Since the values are normalized, a single curve contains information about any diffusion coefficient or ratchet period. The inset shows the normalized net ion velocity for a wider Γ\Gamma range, illustrating a known ratchet property, that at very low and very high frequencies the output of a ratchet is zero.[33] For moderately low Γ\Gamma the behavior is similar to the operation shown in Figure 4b, where the negative net velocity is a result of the injection phenomenon described above. As α\alpha decrease in magnitude, the injection becomes more dominant, and therefore the net velocity becomes more negative. At the moderately high Γ\Gamma regime, the sign and magnitude of the velocity are determined by the time-averaged potential U‾=δVmax⁡+(1−δ)αVmax⁡\overline{U} = \delta V_{\max} + (1-\delta)\alpha V_{\max}. For negative U‾\overline{U} (α<−0.33\alpha< -0.33) the net velocity is positive, and therefore a stopping frequency exists, while for positive U‾\overline{U} (α>−0.33\alpha> -0.33) the net velocity is negative, and there is no stopping frequency, and therefore no velocity reversal.

Normalized net ion velocity characteristic curves

Figure 6. Normalized net ion velocity characteristic curves for ion z=1z = 1, D=1⋅10−5 cm2/sD = 1 \cdot10^{-5}\,\mathrm{cm}^2/\mathrm{s}, and ratchet parameters: L=1 μmL = 1\,\mu\mathrm{m}, xc=0.7x_c = 0.7, for different symmetry factors. (a) δ=0.25\delta= 0.25, Vmax⁡=2.5 VV_{\max} = 2.5\,\mathrm{V}, as function of the normalized frequency. (b) Γ=1\Gamma= 1, Vmax⁡=1 VV_{\max} = 1\,\mathrm{V}, as function of duty cycle.

Figure 6b shows the normalized net ion velocity as a function of δ\delta for moderately high Γ\Gamma, with different symmetry factors α\alpha. As expected, at δ=0\delta= 0 and δ=1\delta= 1, there is no net movement of ions since there are no temporal fluctuations. At α=−1\alpha= -1, the potentials at the positive and negative periods are equal in magnitude, therefore the velocity curve is antisymmetric with respect to δ=0.5\delta= 0.5. These 'sine' shapes are well known in ratchet systems,[13, 27, 33] and are a good validation of our model.

The separation resolution

The selectivity of membranes for different same-charge ions is typically expressed in terms of the ratio of fluxes of the desired and undesired species crossing the membrane.[43, 44] A highly selective membrane will yield a flux ratio on the order of 100:1 for the wanted species, and typically much lower than that.[44, 45, 46, 47, 48] In the case where same-charge ions are transported in opposite directions, none of the unwanted ions will cross the membrane, and this selectivity definition ceases to be relevant. Therefore, a new parameter R\mathcal{R} is introduced, called the separation resolution. It is defined as the ability to separate different same-charge ions according to the difference in their diffusion coefficients. According to this definition, a ratchet membrane can separate two types of ions with a diffusion coefficient difference of ΔD\Delta D, by driving one ion through the membrane at a velocity vnet=RΔDv_{\mathrm{net}}=\mathcal{R}\Delta D, while the other ion is kept at its stopping frequency and is not affected by the ratchet. Since this definition describes a linear relation between the difference in diffusion coefficients and the ion net velocity, it becomes less accurate as ΔD\Delta D increases.

The separation resolution for a certain set of ratchet parameters is calculated according to eq. (7) based on the normalized stopping frequency Γ∗\Gamma^*, and the slope of the characteristic net velocity function vnet/v0=H(Γ)v_{\mathrm{net}}/v_0=\mathcal{H}(\Gamma), as shown for example in Figure 6a (the SI provides the detailed calculation of eq. (7)).

R(α,δ,xc,βVmax⁡,L,z)=∂vnet∂D∣Γ∗=−zβVmax⁡L⋅Γ∗∂H∂Γ∣Γ∗(7)\mathcal{R}(\alpha,\delta,x_c,\beta V_{\max},L,z)=\left.\frac{\partial v_{\mathrm{net}}}{\partial D}\right|_{\Gamma^*}=-\frac{z\beta V_{\max}}{L}\cdot\Gamma^*\left.\frac{\partial\mathcal{H}}{\partial\Gamma}\right|_{\Gamma^*} \tag*{(7)}

Figure 7 shows the separation resolution for different symmetry factors α\alpha and duty-cycles δ\delta. The light blue region corresponds to input signals that do not yield velocity reversal, showing more generally that for sawtooth sharpness xc>0.5x_c>0.5, velocity reversal is possible only with Uˉ<0\bar{U}<0 (for xc<0.5x_c<0.5 velocity reversal is possible only for Uˉ>0\bar{U}>0). High separation resolution is achieved using mid-range symmetry factors (−0.8<α<−0.4,-0.8<\alpha<-0.4,) and mid-range duty-cycles (0.2<δ<0.40.2<\delta<0.4). The effect of each variable cannot be examined separately because they are interconnected but can be generally understood by referring to eq. (7): (i) Low δ\delta leads to lower Γ∗\Gamma^*, since a larger time-period is needed to reach the steady state distribution at τ=t+\tau=t^+. (ii) High α\alpha (in magnitude) reduces ∂H/∂Γ∣Γ∗\left.\partial\mathcal{H}/\partial\Gamma\right|_{\Gamma^*}, due to lower injection. (iii) A combination of high δ\delta and low α\alpha (in magnitude) also reduces ∂H/∂Γ∣Γ∗\left.\partial\mathcal{H}/\partial\Gamma\right|_{\Gamma^*}, since it approaches Uˉ=0\bar{U}=0.

Figure 7. Separation resolution as function of the signal symmetry factor, α\alpha, and duty cycle, δ\delta, for ratchet: L=1 μmL=1\ \mu\mathrm{m}, xc=0.7x_c=0.7, Vmax⁡=2.5 VV_{\max}=2.5\ \mathrm{V}, and z=1z=1.

For ratchets operating near the normalized stopping frequency, the separation resolution is linear with L−1L^{-1}, therefore a low period length is desired. In this work a period of L=1 μmL=1\ \mu\mathrm{m} was used, although devices with significantly lower spatial periods can be fabricated. However, since the stopping frequency is proportional to L−2L^{-2}, such devices will have to operate at much higher signal frequencies. The separation resolution also increases with Vmax⁡V_{\max}, as shown in Figure 8a. For lower voltages the increase is non-linear. This is due to the linear term of Vmax⁡V_{\max} in eq. (7) and an additional increase of the slope of the characteristic velocity function, ∂H/∂Γ∣Γ∗\partial\mathcal{H}/\partial\Gamma|_{\Gamma^*}, as shown in the inset. A resolution of R=12 (cm/s)/(10−5cm2/s)\mathcal{R}=12\ (\mathrm{cm/s})/(10^{-5}\mathrm{cm^2/s}) is obtained with an amplitude of Vmax⁡=5 VV_{\max} = 5\ \mathrm{V} (and would increase for higher amplitudes). Thus, for two monovalent ions with a difference in diffusion coefficients of ΔD=0.01⋅10−5 cm2/s\Delta D = 0.01 \cdot10^{-5}\ \mathrm{cm}^2/\mathrm{s}, which for the prevalent ions in water is a relative difference of about 1%, the maximum separation velocity is Δvnet=R⋅ΔD=0.12 cm/s\Delta v_{\mathrm{net}} = \mathcal{R} \cdot\Delta D = 0.12\ \mathrm{cm}/\mathrm{s}. The effect of the sawtooth sharpness, xcx_c, on the normalized net velocity is shown in Figure 8b. Moderate sharpness, such as xc=0.6x_c = 0.6, exhibit the highest separation resolution, as well as a relatively narrow frequency range, with a high ion net velocity that resembles a resonance, centered around Γ=1.3\Gamma= 1.3. When the sharpness of the sawtooth is below xc=0.5x_c = 0.5, the velocity directions are flipped, and so the normalized velocity curve of xc=0.3x_c = 0.3 is a mirror image of xc=0.7x_c = 0.7. The inset shows the separation resolution as a function of xcx_c. The behavior is antisymmetric around xc=0.5x_c = 0.5. As the sawtooth becomes sharper (xcx_c moves towards 0 or 1) the absolute value of R\mathcal{R} rapidly increases, and then decreases, with an optimal value at moderate sharpness values xc=0.4x_c = 0.4 & 0.60.6. When the sawtooth is spatially symmetric, xc=0.5x_c = 0.5, there is no ratchet effect, hence the net ion velocity is zero.

Separation resolution and characteristic net velocity curves

Figure 8. (a) Separation resolution (in absolute value) as a function of the maximum amplitude Vmax⁡V_{\max}, with xc=0.7x_c = 0.7. The inset shows the characteristic net velocity curves. (b) Characteristic net velocity curves for different xcx_c values, with Vmax⁡=2.5 VV_{\max} = 2.5\ \mathrm{V}. The inset shows the Separation resolution as a function of xcx_c. R∗\mathcal{R}^* is in units of (cm/s)/(10−5cm2/s)(\mathrm{cm}/\mathrm{s})/(10^{-5}\mathrm{cm}^2/\mathrm{s}). Ratchet parameters for both graphs are: L=1 μmL = 1\ \mu\mathrm{m}, α=−0.5\alpha= -0.5, δ=0.25\delta= 0.25 and z=1z = 1.

Drift currents are influenced by the charge number and diffusion coefficient of the ions; therefore, when separating ions with different charge numbers, the separation ability is not determined by a difference in the diffusion coefficient alone, but by differences in their product, zDzD. Eq. (7) cannot be used to calculate the separation resolution in this case, since different ion charge numbers result in different characteristic velocity functions. Therefore, to find the separation resolution, a case-by-case method should be taken. Figure 9 shows an example of such a case for anions. Nitrate (NO3−\mathrm{NO}_3^-, D=1.9⋅10−5 cm2/sD = 1.9 \cdot10^{-5}\ \mathrm{cm}^2/\mathrm{s}), which is a well-known water pollutant, [44, 49] is to be extracted from water with a higher concentration of chlorine (Cl−\mathrm{Cl}^-, D=2.03⋅10−5 cm2/sD = 2.03 \cdot10^{-5}\ \mathrm{cm}^2/\mathrm{s}). Carbonate (CO32−\mathrm{CO}_3^{2-}, D=0.96⋅10−5 cm2/sD = 0.96 \cdot10^{-5}\ \mathrm{cm}^2/\mathrm{s}) is also shown for comparison since it has a similar zDzD value as NO3−\mathrm{NO}_3^-, and is also found in water. [43] In this case, when the ratchet is operated at 47 kHz, which is the stopping frequency of Cl−\mathrm{Cl}^-, the separation velocity of the high charge number ion CO32−\mathrm{CO}_3^{2-} is much higher than of NO3−\mathrm{NO}_3^-. Also note that NO3−\mathrm{NO}_3^- and CO32−\mathrm{CO}_3^{2-} can themselves be separated, even though their zDzD values are very close. The inset of Figure 9 shows the characteristic net velocity curves for different charge numbers, and the separation resolution between same-charge number ions. The separation resolution increases significantly with the charge number, due to the linear term in eq. (7) and an increase of the slope ∂R/∂Γ∣Γ∗\partial\mathcal{R}/\partial\Gamma|_{\Gamma^*}. Another example with common cation pollutants found in water is shown in Figure S2. Lead (Pb2+\mathrm{Pb}^{2+}, D=0.95⋅10−5 cm2/sD = 0.95 \cdot10^{-5}\ \mathrm{cm}^2/\mathrm{s}) can be separated from sodium (Na+\mathrm{Na}^+, D=1.33⋅10−5 cm2/sD = 1.33 \cdot10^{-5}\ \mathrm{cm}^2/\mathrm{s}) with a relatively high velocity since they have a high zDzD difference. However, Copper (Cu2+\mathrm{Cu}^{2+}, D=0.73⋅10−5 cm2/sD = 0.73 \cdot10^{-5}\ \mathrm{cm}^2/\mathrm{s}) cannot be separated from sodium with high velocities, even though they have a non-negligible zDzD difference, since their stopping frequencies coincide.

Net velocity of anions as a function of input signal frequency

Figure 9. The net velocity of Cl−\mathrm{Cl}^{-}, CO32−\mathrm{CO}_{3}^{2-}, and NO3−\mathrm{NO}_{3}^{-} anions as a function of input signal frequency. The units for zD∗zD^{*} are in (10−5 cm2/s)(10^{-5}\,\mathrm{cm}^{2}/\mathrm{s}). The inset shows the velocity characteristic curves and the separation resolution for different ∣z∣|z| values. ∣R∗∣|\mathcal{R}^{*}| is in units of (cm/s)/(10−5 cm2/s)(\mathrm{cm}/\mathrm{s})/(10^{-5}\,\mathrm{cm}^{2}/\mathrm{s}). Ratchet parameters: L=1 μmL = 1\,\mu\mathrm{m}, xc=0.7x_{c} = 0.7, Vmax⁡=−1 VV_{\max} = -1\,\mathrm{V}, α=−0.5\alpha= -0.5, δ=0.25\delta= 0.25.

The net velocity of Na+, Cu2+, and Pb2+ cations as a function of input signal frequency

Figure S2. The separation of lead and copper ions from sodium. Figure S2. The net velocity of Na+\mathrm{Na}^{+}, Cu2+\mathrm{Cu}^{2+}, and Pb2+\mathrm{Pb}^{2+} cations as a function of input signal frequency. The units for zD∗z_D^* are in (10−5 cm2/s)(10^{-5}\,\mathrm{cm}^2/\mathrm{s}). Ratchet parameters: L=1 μmL = 1\,\mu\mathrm{m}, xc=0.7x_c = 0.7, Vmax⁡=1 VV_{\max} = 1\,\mathrm{V}, α=−0.5\alpha= -0.5, δ=0.25\delta= 0.25.

Discussion

In this work we have modelled the performance of a ratchet driving ions assuming an infinitely periodic system in which no concentration gradient develops between spatial periods. This is similar to a photovoltaic cell driving current under short circuit conditions where no power is converted. However, when driving ions between two finite reservoirs, a concentration gradient develops impeding further ion transport, and the transport of ions against a force leads to a production of work. Thus, the current model can be used to describe only the ratchet operation before significant concentration gradients are formed, or a system in which the ratchet is separating two large reservoirs such that the ion concentration within them is hardly perturbed. To model a device that performs work, a concentration gradient must be considered. This can be done by assuming a per-period concentration gradient, or by solving the coupled Nernst-Poisson-Planck equations with finite reservoirs or predefined concentration gradients.

Since in the model presented the electric potential distribution is an input to the calculation, and Poisson’s equation is not solved; the model does not consider the interactions between the ions, the potential being screened by them, nor the columbic forces arising when separating cations and anions. Such conditions can be obtained in extremely dilute solutions or in devices with a length scale that is smaller than the Debye length. For systems that do not comply with these assumptions, the model offers an ideal testcase that can help determine the optimal electric potential distribution for a given application. The screening of the applied potential by the solution ions reduces dramatically the amplitude of the potential modulation experienced in the solution reducing the efficiency of the device. Thus, similar to other electrically driven ion manipulation methods, such as electrodialysis and capacitive deionization, ratchet-based separation is expected to be less applicable to highly concentrated solutions. As above, an estimation of the operable concentrations and obtainable concentration gradients requires solving the coupled Nernst-Poisson-Planck equations.

The unique ability of ratchets to drive particles with the same charge in opposite directions makes them very attractive for ion separation applications. This characteristic may be most significant when targeting the removal of trace ions from a solution where conventional membrane-based separation methods require extreme levels of selectivity. For example, the total amount of lithium in the world’s oceans is enough to meet the increasing global demand in an environmentally sustainable way, but its extraction is highly challenging, due to its low concentration of about 0.15 ppm0.15\,\mathrm{ppm}[50, 51]. Lithium is coventionally positioned with one of the lowest zDzD values, so that it can be separated in a single process from most other cations that are present in ocean water at much higher concentrations, including Mg2+\mathrm{Mg}^{2+}, Ca2+\mathrm{Ca}^{2+}, Na+\mathrm{Na}^{+}, and K+\mathrm{K}^{+}. Moreover, the interaction between the main ions and the trace ions may result in a synergistic effect that can further enhance the selectivity of a ratchet-based separation system. For example, consider a system where a ratcheting membrane is separating two closed compartments, filled with a NaCl aqueous solution with another cation in a trace amount. The ratchet pumps the Na+\mathrm{Na}^{+} ions to one side and the Cl−\mathrm{Cl}^{-} ions to the other, until the build-up of electrostatic forces and backward diffusion negates the net force induced by the ratchet. The ratchet frequency is tuned to drive the trace ions in an opposite direction to that of the sodium ions. Since the trace ions are at a very low concentration, their contribution to the electrostatic potential is negligible. Thus, while the electrostatic potential induced by the separation of the sodium and chlorine ions impedes the transport of the main ions in the solution, it accelerates the oppositely flowing trace ions. Detailed modelling of this effect requires a full solution of the coupled Nernst-Poisson-Planck equations for all the ions in the solution and is left for future work.

For small differences in diffusion coefficients, the separation resolution increases linearly, yet as ΔD\Delta D increases the separation velocity saturates. To reach higher separation velocities, the 'resonance like' behavior (obtained at moderate sawtooth sharpness such as xc=0.6x_c = 0.6) can be used, as shown in Figure 8b. For example, in some microbial electrochemical systems, such as microbial fuel cells (MFCs), operating in physiological environments, there is a great need to achieve high membrane selectivity for H+\mathrm{H}^{+} with respect to Na+\mathrm{Na}^{+} and K+\mathrm{K}^{+}.[52] Under the conditions described in Figure 8b with xc=0.6x_c = 0.6, the maximum velocity for H+\mathrm{H}^{+} is obtained at a normalized frequency of Γ=1.3\Gamma= 1.3 which corresponds to a frequency of 1.2 MHz. For Na+\mathrm{Na}^{+} and K+\mathrm{K}^{+} this frequency translates to normalized frequencies of Γ=9.1\Gamma= 9.1 and Γ=6.2\Gamma= 6.2, respectively. As can be seen in Figure 8b, at such high normalized frequencies the Na+\mathrm{Na}^{+} and K+\mathrm{K}^{+} velocities are near zero leading to a velocity ratio of 500:1 and 350:1, relative to Na+\mathrm{Na}^{+} and K+\mathrm{K}^{+}, respectively.

Velocity reversal can also be used for driving opposite charge ions in the same direction, a process we term ambipolar ion transport. Figure 10 shows an example for ambipolar transport of the main ions in seawater. When the ratchet is operated at 243 kHz, both the negative and positive ions are transported in the same direction at a velocity of 2 cm/s. Since both cations and anions are driven in the same direction, cations and anions are not separated, and the electrostatic potential that opposes ion transport in other cases does not develop. This makes ambipolar ion transport an attractive mechanism for desalination and distillation applications.

Net velocity of Cl− and Na+ showing ambipolar transport

Figure 10. The net velocity of Cl−\mathrm{Cl}^{-} and Na+\mathrm{Na}^{+} showing ambipolar transport. Ratchet parameters: L=1 μmL = 1\ \mu\mathrm{m}, xc=0.6x_c = 0.6, Vmax⁡=5 VV_{\max} = 5\ \mathrm{V}, α=−0.38\alpha= -0.38, δ=0.25\delta= 0.25.

Conclusion

In this work we have laid the theoretical groundwork for ratchet-driven ion separation. We have shown that a flashing ratchet can be used to drive ions with the same charge number in opposite directions based on the difference in diffusion coefficients. This unique ratchet property paves the way for rapid extraction of trace ions from solutions where conventional membrane-based separation processes do not offer sufficient selectivity. We define the ratchet separation resolution and show that under moderate voltages, prevalent ions in water with a 1% relative difference in diffusion coefficients can be driven in opposite directions with a velocity difference of 1.2 mm/s. Moreover, non-linearities in the ion velocity with the input signal amplitude and ion valence can be further utilized to enhance the ratchet selectivity. Thus, ratchet-based ion pumping systems may prove beneficial for applications such as water treatment, bio-medical devices, ion sensors, solar fuels generators and more.

Acknowledgments

The authors would like to acknowledge Francesca Toma for helpful discussions. AH acknowledges the support of the Boris Mints Institute. JWA was supported by the Joint Center for Artificial Photosynthesis, a DOE Energy Innovation Hub, supported through the Office of Science of the United States. Department of Energy under Award No. DE-SC0004993. SA acknowledges the support of the Gordon and Betty Moore Foundation under a Moore Inventor Fellowship (GBMF grant #5641) and The Beall Family Foundation (UCI Beall Innovation Award). GS thanks the Azrieli Foundation for financial support within the Azrieli Fellows program.

Conflict of Interest

GS, JWA, and SA filed patent applications US 16/907,076 and US 17/125,341 for ratchet-based ion pumping membrane systems. There are no other conflicts of interest to declare.

Author Contributions

Conceptualization: GS, SA

Investigation: AH, GS

Methodology: AH, JWA, GS

Data curation: AH

Formal analysis: AH

Visualization: AH, GS

Writing – original draft: AH, GS

Writing – review and editing: AH, GS, JWA, SA

Supervision, Project Administration, and Funding Acquisition: GS

Supporting Information

Model Validation

To validate our numerical model, we compared our simulation to the analytical solution presented by Kedem et al.[13], and developed by Rozenbaum[27] for low energy (compared to the thermal energy). The analytical solution uses a biharmonic potential distribution, given in eq. (8):

V(x)=V1sin⁡(2πx/L)+V2sin⁡(4πx/L)(8)V(x) = V_1\sin(2\pi x/L) + V_2\sin(4\pi x/L) \tag*{(8)}

Here we defined V1=VmaxV_1 = V_{max} and used V2=Vmax/5V_2 = V_{max}/5 to get a spatially asymmetric potential, that is similar in shape to a sawtooth. The particles net velocity is calculated by eq. (9)[13]:

vnet,analytic=π4DLβ3V12V2(1−α)2[(1+α)Φ1(Γ,δ)+(1−α)Φ2(Γ,δ)]v_{net,analytic} = \frac{\pi}{4}\frac{D}{L}\beta^3 V_1^2 V_2(1-\alpha)^2[(1+\alpha)\Phi_1(\Gamma,\delta)+(1-\alpha)\Phi_2(\Gamma,\delta)]
Φ1(Γ,δ)=12π2xC(x,y),Φ2(Γ,δ)=12π2xG(x,y)\Phi_1(\Gamma,\delta) = \frac{12}{\pi^2}xC(x,y),\quad\Phi_2(\Gamma,\delta) = \frac{12}{\pi^2}xG(x,y)
x=βVmaxΓ2π,y=2π(1−δ)x = \frac{\beta V_{max}\Gamma}{2\pi},\quad y = 2\pi(1-\delta)
C(x,y)=∑n=1∞x(7+2x2n2)(1−cos⁡yn)(1+x2n2)2(16+x2n2),G(x,y)=(1−2y2π)C(x,y)−D(x,y)2π(9)C(x,y) = \sum_{n=1}^{\infty}\frac{x(7+2x^2n^2)(1-\cos yn)}{(1+x^2n^2)^2(16+x^2n^2)},\quad G(x,y)=\left(1-2\frac{y}{2\pi}\right)C(x,y)-\frac{D(x,y)}{2\pi} \tag*{(9)}
D(x,y)=∑n=2∞∑m=1−n−1[B(x,y,n,m)+B(x,y,m,n)]+∑n,m=1∞B(x,y,n,m)D(x,y)=\sum_{n=2}^{\infty}\sum_{m=1-n}^{-1}[B(x,y,n,m)+B(x,y,m,n)]+\sum_{n,m=1}^{\infty}B(x,y,n,m)
B(x,y,n,m)=x[5n+(n+m)(4−x2n2)][sin⁡yn(1−cos⁡ym)+sin⁡ym(1−cos⁡yn)](n+m)m(1+x2n2)(16+x2n2)(1+x2(n+m)2)B(x,y,n,m)=\frac{x[5n+(n+m)(4-x^2n^2)][\sin yn(1-\cos ym)+\sin ym(1-\cos yn)]}{(n+m)m(1+x^2n^2)(16+x^2n^2)(1+x^2(n+m)^2)}

To compare our numerical model to the analytical model, simulations were performed with the potential distribution of eq. (8). Figure S1 shows a comparison of the normalized net velocity as a function of the normalized frequency, calculated with both models, for different potential amplitudes. The two models agree well for low amplitudes, i.e., βVmax<1\beta V_{max}<1 (Vmax<25.7V_{max}<25.7 mV, @25°C), while for higher amplitudes the models diverge. This result is to be expected since the analytical model was developed with a low energy assumption. Since ion transport problems usually require higher potentials to drive a sufficient current, this emphasizes the need for a numerical solution.

Model validation plots

Figure S1. Model validation. Numerical vs. analytical solution for a potential distribution described by eq. (S1), ratchet parameters: : L=10L = 10 μ\mum, α=−0.75\alpha= -0.75, δ=0.25\delta= 0.25, and (a) VmaxV_{max} between 0.5kT0.5kT to 2kT2kT, (b) VmaxV_{max} between 5kT5kT to 11kT11kT. For clarity kTkT is used instead of the full expression β−1=kBTr/e\beta^{-1}=k_BT_r/e.

Detailed calculation of the separation resolution

We would like to find the separation resolution for any set of parameters, represented by a single characteristic net velocity curve H(Γ)\mathcal{H}(\Gamma) and its corresponding normalized stopping frequency Γ∗\Gamma^*. Applying the chain rule on the definition of the separation resolution, and remembering at the normalized stopping frequency, H(Γ∗)=0\mathcal{H}(\Gamma^*)=0, we obtain:

R=∂vnet∂D∣Γ∗=∂(v0⋅H(Γ))∂D∣Γ∗=∂v0∂D⋅H(Γ∗)+v0∂H∂D∣Γ∗=v0∂H∂Γ∣Γ∗∂Γ∂D∣Γ∗(10)\mathcal{R}=\left.\frac{\partial v_{net}}{\partial D}\right|_{\Gamma^*}=\left.\frac{\partial(v_0\cdot\mathcal{H}(\Gamma))}{\partial D}\right|_{\Gamma^*}=\left.\frac{\partial v_0}{\partial D}\cdot\mathcal{H}(\Gamma^*)+v_0\frac{\partial\mathcal{H}}{\partial D}\right|_{\Gamma^*}=v_0\left.\frac{\partial\mathcal{H}}{\partial\Gamma}\right|_{\Gamma^*}\left.\frac{\partial\Gamma}{\partial D}\right|_{\Gamma^*} \tag*{(10)}

Where:

∂R∂D=∂∂D(fL2zDβVmax⁡)=−fL2βVmax⁡zD2=−RD(11)\frac{\partial\mathcal{R}}{\partial D} = \frac{\partial}{\partial D}\left(\frac{fL^2}{z_D\beta V_{\max}}\right) = -\frac{fL^2}{\beta V_{\max}z_D^2} = -\frac{\mathcal{R}}{D} \tag*{(11)}

Inserting into eq. (10) yields:

R=(zDβVmax⁡L)(−Γ∗D)⋅∂H∂Γ∣Γ∗=−zβVmax⁡L⋅Γ∗∂H∂Γ∣Γ∗(12)\mathcal{R} = \left(\frac{z_D\beta V_{\max}}{L}\right)\left(-\frac{\Gamma^*}{D}\right)\cdot\left.\frac{\partial\mathcal{H}}{\partial\Gamma}\right|_{\Gamma^*} = -\frac{z\beta V_{\max}}{L}\cdot\Gamma^*\left.\frac{\partial\mathcal{H}}{\partial\Gamma}\right|_{\Gamma^*} \tag*{(12)}

References

  1. [1]Tang, C. & Bruening, M. L. Ion separations with membranes. J. Polym. Sci. 58, 2831–2856 (2020).DOI
  2. [2]Epsztein, R., DuChanois, R. M., Ritt, C. L., Noy, A. & Elimelech, M. Towards single-species selectivity of membranes with subnanometre pores. Nat. Nanotechnol. 15, 426–436 (2020).DOI
  3. [3]Sholl, D. S. & Lively, R. P. Seven chemical separations to change the world. Nature 532, 435–437 (2016).DOI
  4. [4]World Health Organization. Guidelines for drinking-water quality. (2017).
  5. [5]Tang, C., Yaroshchuk, A. & Bruening, M. L. Flow through negatively charged, nanoporous membranes separates Li+and K+due to induced electromigration. Chem. Commun. 56, 10954–10957 (2020).DOI
  6. [6]Armstrong, J. A., Bernal, E. E. L., Yaroshchuk, A. & Bruening, M. L. Separation of ions using polyelectrolyte-modified nanoporous track-etched membranes. Langmuir 29, 10287–10296 (2013).DOI
  7. [7]Yaroshchuk, A. E. Asymptotic behaviour in the pressure-driven separations of ions of different mobilities in charged porous membranes. J. Memb. Sci. 167, 163–185 (2000).DOI
  8. [8]Yaroshchuk, A. E. Dielectric exclusion of ions from membranes. Advances in Colloid and Interface Science 85, 193–230 (2000).pubmed.ncbi.nlm.nih.gov/10768481
  9. [9]Yaroshchuk, A. E. Negative rejection of ions in pressure-driven membrane processes. Adv. Colloid Interface Sci. 139, 150–173 (2008).DOI
  10. [10]Hänggi, P. & Marchesoni, F. Artificial Brownian motors: Controlling transport on the nanoscale. Rev. Mod. Phys. 81, 387–442 (2009).DOI
  11. [11]Reimann, P. Brownian motors: Noisy transport far from equilibrium. Phys. Rep. 361, 57–265 (2002).DOI
  12. [12]Lau, B. & Kedem, O. Electron ratchets: State of the field and future challenges. J. Chem. Phys. 152, 200901 (2020).DOI
  13. [13]Kedem, O., Lau, B. & Weiss, E. A. How to Drive a Flashing Electron Ratchet to Maximize Current. Nano Lett. 17, 5848–5854 (2017).DOI
  14. [14]Kedem, O., Lau, B. & Weiss, E. A. Mechanisms of Symmetry Breaking in a Multidimensional Flashing Particle Ratchet. ACS Nano 11, 7148–7155 (2017).DOI
  15. [15]Kedem, O., Lau, B., Ratner, M. A. & Weiss, E. A. Light-responsive organic flashing electron ratchet. Proc. Natl. Acad. Sci. 114, 8698–8703 (2017).DOI
  16. [16]Tanaka, T., Nakano, Y. & Kasai, S. GaAs-based nanowire devices with multiple asymmetric gates for electrical brownian ratchets. Jpn. J. Appl. Phys. 52, (2013).DOI
  17. [17]Linke, H. et al. Experimental tunneling ratchets. Science (80-. ). 286, 2314–2317 (1999).pubmed.ncbi.nlm.nih.gov/10600735
  18. [18]Mikhnenko, O. V., Collins, S. D. & Nguyen, T. Q. Rectifying electrical noise with an ionic-organic ratchet. Adv. Mater. 27, 2007–2012 (2015).DOI
  19. [19]Hu, Y. et al. Understanding the Device Physics in Polymer-Based Ionic-Organic Ratchets. Adv. Mater. 29, (2017).DOI
  20. [20]Hubmann, S. et al. Giant ratchet magneto-photocurrent in graphene lateral superlattices. Phys. Rev. Res. 2, 33186 (2020).
  21. [21]Roeling, E. M. et al. Organic electronic ratchets doing work. Nat. Mater. 10, 51–55 (2011).DOI
  22. [22]Roeling, E. M. et al. The performance of organic electronic ratchets. AIP Adv. 2, (2012).DOI
  23. [23]Andersson, O., Maas, J., Gelinck, G. & Kemerink, M. Scalable Electronic Ratchet with Over 10% Rectification Efficiency. Adv. Sci. 7, (2020).DOI
  24. [24]Olbrich, P. et al. Terahertz ratchet effects in graphene with a lateral superlattice. Phys. Rev. B 93, 1–15 (2016).DOI
  25. [25]Falterm eier, P. et al. Helicity sensitive terahertz radiation detection by dual-grating-gate high electron mobility transistors. J. Appl. Phys. 118, 084301 (2015).
  26. [26]Kabir, M., Unluer, D., Li, L., Ghosh, A. W. & Stan, M. R. Electronic Ratchet : A Non-Equilibrium , Low Power. 2011 11th IEEE Int. Conf. Nanotechnol. 482–486 (2011). doi:10.1109/NANO.2011.6144610DOI
  27. [27]Rozenbaum, V. M. High-temperature brownian motors: Deterministic and stochastic fluctuations of a periodic potential. JETP Lett. 88, 342–346 (2008).DOI
  28. [28]Marbach, S. & Bocquet, L. Active sieving across driven nanopores for tunable selectivity. J. Chem. Phys. 147, (2017).DOI
  29. [29]Marbach, S., Kavokine, N. & Bocquet, L. Resonant osmosis across active switchable membranes. J. Chem. Phys. 152, (2020).DOI
  30. [30]Parrondo, J. M. R., Blanco, J. M., Cao, F. J. & Brito, R. Efficiency of Brownian motors. Europhys. Lett. 43, 248–254 (1998).DOI
  31. [31]Nouri, R. & Guan, W. Nanofluidic charged-coupled devices for controlled DNA transport and separation. Nanotechnology 32, 345501 (2021).DOI
  32. [32]Ardo, S. et al. Ratchet-based ion pumping membrane systems. US patent application 16/907,076 (2020).
  33. [33]Rozenbaum, V. M., Korochkova, T. Y., Chernova, A. A. & Dekhtyar, M. L. Brownian motor with competing spatial and temporal asymmetry of potential energy. Phys. Rev. E - Stat. Nonlinear, Soft Matter Phys. 83, 1–10 (2011).pubmed.ncbi.nlm.nih.gov/21728503
  34. [34]Kodaimati, M. S., Kedem, O., Schatz, G. C. & Weiss, E. A. Empirical Mappings of the Frequency Response of an Electron Ratchet to the Characteristics of the Polymer Transport Layer. J. Phys. Chem. C 123, 22050–22057 (2019).DOI
  35. [35]Skaug, M. J., Schwemmer, C., Fringes, S., Rawlings, C. D. & Knoll, A. W. Nanofluidic rocking Brownian motors. Science (80-. ). 359, 1505–1508 (2018).DOI
  36. [36]Schwemmer, C., Fringes, S., Duerig, U., Ryu, Y. K. & Knoll, A. W. Experimental Observation of Current Reversal in a Rocking Brownian Motor. Phys. Rev. Lett. 121, 104102 (2018).DOI
  37. [37]Nicollier, P. et al. Nanometer-Scale-Resolution Multichannel Separation of Spherical Particles in a Rocking Ratchet with Increasing Barrier Heights. Phys. Rev. Appl. 15, 034006 (2021).DOI
  38. [38]Chen, Q., Ai, B. Q. & Xiong, J. W. Brownian transport of finite size particles in a periodic channel coexisting with an energetic potential. Chaos 24, (2014).DOI
  39. [39]Śłapik, A., Łuczka, J., Hänggi, P. & Spiechowicz, J. Tunable Mass Separation via Negative Mobility. Physical Review Letters 122, (2019).DOI
  40. [40]Motz, T., Schmid, G., Hänggi, P., Reguera, D. & Rubí, J. M. Optimizing the performance of the entropic splitter for particle separation. J. Chem. Phys. 141, 074104 (2014).DOI
  41. [41]Reguera, D. et al. Entropic splitter for particle separation. Phys. Rev. Lett. 108, 1–5 (2012).pubmed.ncbi.nlm.nih.gov/22324667
  42. [42]Yang, B., Long, F. & Mei, D. C. Negative mobility and multiple current reversals induced by colored thermal fluctuation in an asymmetric periodic potential. Eur. Phys. J. B 85, 2–7 (2012).DOI
  43. [43]Luo, T., Abdu, S. & Wessling, M. Selectivity of ion exchange membranes: A review. J. Memb. Sci. 555, 429–454 (2018).DOI
  44. [44]Sata, T. Studies on anion exchange membranes having permselectivity for specific anions in electrodialysis — effect of hydrophilicity of anion exchange membranes on permselectivity of anions. 167, 1–31 (2000).DOI
  45. [45]Sata, T., Sata, T. & Yang, W. Studies on cation-exchange membranes having permselectivity between cations in electrodialysis. 206, 31–60 (2002).DOI
  46. [46]Luo, T., Roghmans, F. & Wessling, M. Ion mobility and partition determine the counter-ion selectivity of ion exchange membranes. J. Memb. Sci. 597, 117645 (2020).DOI
  47. [47]Acar, E. T., Buchsbaum, S. F., Combs, C., Fornasiero, F. & Siwy, Z. S. Biomimetic potassium-selective nanopores. 1–8 (2019).
  48. [48]Li, X. et al. Fast and selective fluoride ion conduction in sub-1-nanometer metal-organic framework channels. Nat. Commun. 10, 1–12 (2019).DOI
  49. [49]T. Matos, C., Velizarov, S., G. Crespo, J. o & A.M. Reis, M. Simultaneous removal of perchlorate and nitrate from drinking water using the ion exchange membrane bioreactor c ... bioreactor concept. water Res. 40, (2006).pubmed.ncbi.nlm.nih.gov/16343587
  50. [50]Yang, S., Zhang, F., Ding, H. & He, P. Lithium Metal Extraction from Seawater. Joule 2, 1648–1651 (2018).DOI
  51. [51]Swain, B. Recovery and recycling of lithium : A review. Sep. Purif. Technol. 172, 388–403 (2017).DOI
  52. [52]Harnisch, F. & Schrøder, U. Selectivity versus Mobility : Separation of Anode and Cathode in Microbial Bioelectrochemical Systems. 921–926 (2009). doi:10.1002/cssc.200900111DOI

Paper details

vlnc:W_feqv8yr6
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents