Slow spin-lattice relaxation dynamics in YbVO4 revealed by extended thermal impedance spectroscopy from AC susceptibility and AC magnetocaloric measurements

Abstract

Alternating (AC) magnetic fields can induce not only an alternating magnetization in materials, but also an alternating temperature via the magnetocaloric effect. The latter effect is typically neglected when performing AC susceptibility measurements, but consideration of both effects on an equal footing is necessary in order to reliably distinguish between internal and external causes of magnetic response and accurately extract quantitative information about relaxation processes. In order to address this, we have developed a method to measure the AC magnetocaloric effect that is compatible with AC susceptibility measurements, and also a framework to analyze these data in combination. We demonstrate the efficacy of this approach using YbVO4, a material for which strong single-ion anisotropy leads to slow spin-lattice relaxation at low temperatures via a phonon bottleneck effect. We report AC magnetic susceptibility and AC magnetocaloric effect measurements for this material as a function of field and frequency at a temperature of 3 K. We analyze the data using a discretized thermal model, and extract the field-dependence of the intrinsic spin-lattice relaxation rate. This demonstration experiment illustrates a general approach to quantitatively address multiple measured quantities in driven systems using a unified thermal circuit analysis. The thermal analysis methods presented in this report can be extended to study other magnetic, dielectric, and elastic materials exhibiting a complex response to an external driving field in the presence of internal and external relaxation, particularly when an energy dissipation process is within an accessible frequency regime.

Introduction

AC magnetic susceptibility, χAC\chi_{\mathrm{AC}}, describes the magnetic response of a material to an oscillating magnetic field [1]. The zero frequency limit defines the isothermal susceptibility, χT\chi_{\mathrm{T}}, for which all the internal subsystems (spins, phonons, etc) are in equilibrium. For non-zero frequencies, χ\chi, the spin and lattice subsystems may not have enough time to equilibrate and the response can acquire a frequency dependence, χAC(ω)\chi_{\mathrm{AC}}(\omega). A classic example is the phonon-bottleneck effect that is observed at low temperatures in many magnetic materials that exhibit magnetic anisotropy [2]. Oscillating magnetic fields also necessarily result in a thermal response due to the magnetocaloric effect (MCE). Thermal relaxation to the bath, as well as internal relaxation processes, are typically neglected in magnetic measurements because thermal equilibration is assumed to be fast [3, 4, 5]. However, in systems with slow spin dynamics relative to the driving frequency, this assumption is unwarranted. To account for magnetization-induced heat dynamics, a full treatment of the combined magnetic and thermal response is required. Here, we provide such a framework to analyze the AC magnetic susceptibility in concert with the AC magnetocaloric response of materials. Our approach builds upon earlier work [6] to develop an extended thermal impedance spectroscopy that fully describes the effective magnetic and thermal response functions of the material coupled to a thermal bath. We also describe a practical experimental method to measure the AC MCE that is compatible with standard AC magnetic susceptibility experiments.

We specifically choose the magnetic insulator YbVO4_4 to demonstrate these effects. In this material, the Crystal Electric Field (CEF) splits the Hund’s rule ground state multiplet of the Yb3+^{3+} ion over a wide energy range, resulting in a Kramers doublet ground state with the first excited state an equivalent of 91.7 K higher in energy (see Figure 1(a)) [7]. The effective interaction between nearby ions is primarily via dipolar interactions, resulting in a relatively low Néel temperature of just 93 mK [8]. As we will show, the combination of strong magnetic anisotropy (large CEF splitting), weak coupling between the moments, and weak coupling to phonons (due to the Kramers nature of the doublet ground state), make the dynamics of the Yb moments slow relative to typical driving frequencies at low temperatures, and hence render this an especially useful material to demonstrate our approach.

Schematic diagrams of CEF levels, thermal circuit model, and AC susceptibility and AC magnetocaloric effect responses

Figure 1. (a) Schematic diagram illustrating the CEF levels and indirect transition corresponding to Yb3+\mathrm{Yb}^{3+} ion embedded in the YbVO4_4 crystal field environment. The lower two levels represent the ground state Kramers doublet, which are split when an external magnetic field is oriented along the cc-axis. The higher energy states correspond to the excited states of the crystal field levels. We consider a scenario where the temperature is much less than the Debye temperature. (b) Schematic diagram illustrating the components of the discretized thermal circuit model considered in this report. The coefficients and time constants are defined in the main text. (c,d) Schematic diagrams illustrating solutions of the equivalent thermal circuit, and using parameters characteristic of YbVO4_4 at 3K. In the left panels, the normalized response is plotted to illustrate the phase difference between the time-dependent solution and the signals. In the middle panels, solid lines represent the real components (χAC′\chi_{\mathrm{AC}}' and ΓAC′\Gamma_{\mathrm{AC}}'), and dashed lines represent the imaginary components (χAC′′\chi_{\mathrm{AC}}'' and ΓAC′′\Gamma_{\mathrm{AC}}''). In the right panels, the imaginary components of each solution are plotted against their respective real parts in a Cole-Cole plot. This representation maintains a fixed aspect ratio of 1:1 for the xx and yy axes.

The relevant internal dynamics affecting χAC(ω)\chi_{\mathrm{AC}}(\omega) in YbVO4_4 are governed by the spin-lattice relaxation rate. An applied magnetic field lifts the degeneracy of the Kramers ground state doublet of the Yb ions. If this is done fast enough relative to the characteristic spin-lattice relaxation time, occupation numbers of the distinct CEF states cannot be changed rapidly enough, and the combined spin and lattice system is no longer in thermal equilibrium. Spin-lattice relaxation occurs by transitions between the distinct CEF eigenstates and is either direct (involving a single phonon) or indirect (the transition in volves intermediate states and two or more phonons). For Yb ions in YbVO4_4, direct transitions are not allowed by symmetry (see Appendix. § 3.3), and the ion can only relax by indirect processes (Figure 1(a)). Zeeman splitting of the CEF eigenstates necessarily leads to a strong field dependence of the associated relaxation rates, making this an especially useful material system to identify internal relaxation effects since these can be readily tuned.

Spin-lattice relaxation time scales can be surprisingly long in rare-earth compounds that exhibit large magnetic anisotropies [2]. In YbVO4_4, at a temperature much lower than the Debye temperature of the lattice, very few phonons are available to participate in the dynamics, resulting in a low transition probability – a manifestation of the phonon bottleneck effect. The indirect nature of the transition effectively decouples the material into separate baths of spins and phonons (Figure 1(b)) for quite modest frequencies, with a long internal time constant τint\tau_{\mathrm{int}} that describes the non-instantaneous relaxation between these two baths. The magnitude of τint\tau_{\mathrm{int}} can be related to an effective internal heat conduction rate κint\kappa_{\mathrm{int}} (where κint\kappa_{\mathrm{int}} is different from the lattice thermal conductivity and should not be confused with it) and the heat capacities associated with the spin and lattice degrees of freedom, C4fC_{4f} and ClC_l respectively: τint=ClC4fκint(Cl+C4f)\tau_{\mathrm{int}} = \frac{C_l C_{4f}}{\kappa_{\mathrm{int}}(C_l+C_{4f})}. As described below, we find characteristic frequencies of order 10 to 100 Hz at a temperature of 3 K, with the value depending on the value of the applied magnetic field, following an exponential functional form.

The spin subsystem can be assigned a well-defined temperature on these timescales because internal equilibration processes are sufficiently fast to establish thermal equilibrium within the spin system on a shorter timescale. In analogy with nuclear spins [9], dipolar interactions between Yb spins, although weak, can be effective because the spin splittings are nearly resonant with each other. Moreover, the external perturbations – the applied magnetic field and the spin–lattice temperature difference – are spatially uniform across the sample, which leads to a uniform spin temperature in our experimental geometry even in the absence of additional internal equilibration processes within the spin subsystem.

In addition to internal relaxation processes, external relaxation can also affect χAC(ω)\chi_{\mathrm{AC}}(\omega). Here, the issue is related to the flow of energy between the material and the environment, which is typically idealized as a heat bath (Figure 1(b)). Whereas the internal relaxation is intrinsic to any given material, external relaxation, characterized by a timescale τext=Clκext\tau_{\mathrm{ext}} = \frac{C_l}{\kappa_{\mathrm{ext}}} (where κext\kappa_{\mathrm{ext}} characterizes thermal conduction from the lattice to the bath) that can vary depending on experimental details. External relaxation must be accounted for if the internal relaxation time is to be quantitatively determined by any experiment. Furthermore, external relaxation plays a significant role in the effective MCE response of materials.

MCE refers to the temperature change in a material that responds to variations in an external magnetic field [10, 11]. It has been extensively studied and applied in various contexts, such as adiabatic demagnetization refrigeration techniques [12] and in characterizing phase transitions [13, 14]. For rare earth containing materials in the paramagnetic state, large magnetic and MCE responses can be anticipated based on the associated large entropy of the spin system [15, 16], and this is also true of YbVO4_4. The dominant method that is typically used for MCE measurements is in the time domain, in response to a swept magnetic field (for a review, see, for example, [11]). While several previous studies attempted to measure the MCE in periodically changing fields (i.e. an AC, or dynamic, MCE) [17, 18], quantitative analysis of the response function has been limited [19, 20], and to date a generally-applicable formal analysis has not been available. In the present work we develop an appropriate thermal model that accounts for internal and external relaxation, and demonstrate a method to measure the AC MCE that is compatible with standard AC susceptibility tools.

The model that we develop to account for the coupled magnetic and thermal response functions is based on discrete thermal elements (magnetic species, lattice, thermal sensor, thermal bath) and neglects any/all thermal inhomogeneity that might be present in a real system. Hence, for this model to be applicable, experiments should be designed in such a way that the heat flow is described by a well-defined circuit where each element is in internal thermal equilibrium. In the present case, the characteristic timescale for thermal transport across the width of the sample is estimated to be tens of microseconds in the regime of interest 2. Since we probe the material in a frequency range that is considerably slower than this, we are safe in our assumption of there being negligible thermal gradients across the sample, but this needs to be verified for any given material to be studied, and clearly delineates the regime in which this analysis is meaningful.

The model that we develop also neglects glassy effects associated with non-ergodic systems. Such systems have more complex internal relaxation, beyond the scope of the present work. Nevertheless, we note that AC MCE measurements can still be anticipated to be a useful complement to AC susceptibility measurements even in such cases.

The major finding of this report is summarized in Figure 1(c,Figure 1d), where the two specific response functions χAC(ω)\chi_{AC}(\omega) (describing the magnetic response) and ΓAC(ω)\Gamma_{AC}(\omega) (describing the caloric response) can be derived by analytically solving a thermal circuit model, and can both be measured experimentally. We will use this formalism to extract the intrinsic spin-lattice relaxation time in YbVO4_4 as a function of field at a temperature of 3K.

Experimental methods

Single crystals of YbVO4_4 and GdVO4_4 were synthesized via slow cooling in a flux of Pb2_2V2_2O7_7 using a mixture of high-purity rare-earth oxides precursors, Yb2_2O3_3 (99.99% purity from Alfa Aesar, CAS Number: 1314-37-0) and Gd2_2O3_3 (99.99% purity from Alfa Aesar, CAS Number: 12064-62-9). More details related to the flux-growth synthesis method can be found in Refs. [23, 24, 25].

AC susceptibility measurements were performed in a Quantum Design Magnetic Property Measurement System (model MPMS-3) using the AC susceptometer measurement option, following standard protocols as described elsewhere [1]. YbVO4_4 grows as long, thin crystals, with the c-axis directed along the long axis of the crystal. Measurements were performed with the magnetic field oriented along this direction. Demagnetization effects were minimal given the high aspect ratio of the crystals used for the experiments.

AC MCE was performed using a customized probe within the same MPMS-3, ensuring a direct comparison of the two techniques can be made. The MCE measurement device consists of a polished sample with a thickness between 30-100 μ\mum, a thermal sensor attached to the top surface of the sample, and a quartz sample holder that is thermally anchored to the bottom surface of the sample. We employ a resistive sensor, in this instance choosing RuOx_x thin film sensors for their sensitivity in the regime of interest. The RuOx_x sensor is connected to a Wheatstone resistance bridge comprising three other identical RuOx_x resistors to improve sensitivity, with the other elements of the bridge thermally anchored to the heat bath (located on the part of the probe far apart from the measured material). Since the AC MCE results in an AC thermal signature, the signal averaging advantages of a lock-in technique can be used to measure the temperature oscillations. Moreover, since we use a resistive thermal sensor, we can employ a demodulation technique, effectively measuring the response at the sidebands formed from the combined effect of the AC current used to measure the resistance of the RuOx_x sensor (the carrier frequency) and the AC change in temperature associated with the AC magnetic field (the signal). A practical consideration is that the thermal sensor needs to have negligible magnetoresistance, at least for field variations corresponding to the amplitude of AC field; this is not an overly stringent requirement for AC amplitudes of a few Oe, and can be easily checked. Further details of the experiment, especially related to signal demodulation, are described in Appendix E.

Heat flow model

In order to extend the analysis of MCE into the frequency domain, we introduce and develop a heat exchange model based on a discretized thermal analog circuit. This approach builds on similar recent work that utilized an AC thermal impedance analysis to access spin-lattice relaxation dynamics [6], but here extended to cover complex caloric responses. The physical experiment necessarily introduces several characteristic time scales, associated with heat exchange between the sample and the bath, as well as heat exchange between the spin and phonon subsystems described above. To account for these, we first describe the complete thermodynamic model of the experimental setup.

Figure 1(b) shows the schematic heat flow diagram. We apply a periodic magnetic field H(t)H(t) and measure the magnetization of the Yb 4f spin subsystem M(t)M(t) as well as the temperature of the lattice Tlat(t)T^{\mathrm{lat}}(t). As we apply a magnetic field, the magnetization and temperature of the 4f subsystem changes, bringing it out of thermal equilibrium with the lattice. This leads to heat flow between the 4f subsystem and the lattice, as well as between the lattice and the environment (idealized as a heat bath). For simplicity, we initially assume an idealized thermal sensor, which has zero heat capacity and is able to instantaneously measure the temperature of the crystal lattice. In Appendix E we expand the thermal model to include a realistic thermal sensor that is also able to exchange heat with the sample.

The thermodynamics of the 4f spins is generated by their free energy (using TT and HH as variables),

dF4f=−S4fdT4f−M4fdH4f,(1)dF^{4f}=-S^{4f}dT^{4f}-M^{4f}dH^{4f}, \tag*{(1)}

where S4fS^{4f} and M4fM^{4f} are the 4f subsystem’s entropy and magnetization respectively. Considering the partial derivatives of S4fS^{4f} and M4fM^{4f} with respect to temperature and field 3, it is possible to write a matrix of the thermodynamic coefficients that describes the changes in the entropy and magnetization associated with the 4f electrons as a consequence of changes in temperature (dTdT) and field (dHdH) [26]:

\begin{bmatrix} dS \\ dM \end{bmatrix}^{4f} = \begin{bmatrix} \frac{C}{T_{0}} & \gamma\\ \gamma& \chi\end{bmatrix}^{4f} \begin{bmatrix} dT \\ dH \end{bmatrix}^{4f}, \tag*{(2)}\end{bmatrix}

where C4f=T0∂S4f∂TC^{4f}=T_{0}\frac{\partial S^{4f}}{\partial T}, γ4f=∂S4f∂H\gamma^{4f}=\frac{\partial S^{4f}}{\partial H}, and χ4f=∂M4f∂H\chi^{4f}=\frac{\partial M^{4f}}{\partial H} are the intrinsic specific heat, magnetocaloric, and isothermal magnetic susceptibility coefficients associated with the 4f subsystem respectively, and T0T_{0} is the bath temperature for the 4f subsystem (provided by the lattice, TlatT^{\mathrm{lat}} below).

If there were no heat exchange between the 4f subsystem and the lattice, there would be no entropy change in the 4f subsystem, dS4f=0dS^{4f}=0. Thus we need to consider non-adiabatic heat exchange between the 4f subsystem and the lattice, as well as between the lattice and the external heat bath,

q4f←lat=T4fdS4fdt=−κint(dT4f−dTlat)(3)q_{4f\leftarrow\mathrm{lat}}=T^{4f}\frac{dS^{4f}}{dt}=-\kappa_{\mathrm{int}}\left(dT^{4f}-dT^{\mathrm{lat}}\right) \tag*{(3)}

where q4f←latq_{4f\leftarrow\mathrm{lat}} is heat flux from lattice to the 4f spins and κint\kappa_{\mathrm{int}} is the heat link between the two. These equations need to be accompanied by equations for heat flow into the lattice, both from the 4f subsystem and from the heat bath:

TlatdSlatdt=−q4f←lat−qbath→lat=κint(dT4f−dTlat)−κext(dTlat−dTbath)\begin{aligned} T^{\mathrm{lat}}\frac{dS^{\mathrm{lat}}}{dt}=-q_{4f\leftarrow\mathrm{lat}}-q_{\mathrm{bath}\rightarrow\mathrm{lat}} \\ &=\kappa_{\mathrm{int}}\left(dT^{4f}-dT^{\mathrm{lat}}\right)-\kappa_{\mathrm{ext}}\left(dT^{\mathrm{lat}}-dT^{\mathrm{bath}}\right) \end{aligned}
dSlatdt=ClTlatdTlatdt(4)\frac{dS^{\mathrm{lat}}}{dt}=\frac{C^{\mathrm{l}}}{T^{\mathrm{lat}}}\frac{dT^{\mathrm{lat}}}{dt} \tag*{(4)}

where dSlatdS^{\mathrm{lat}} is the change of entropy of the lattice, and κext\kappa_{\mathrm{ext}} is the thermal link between the lattice and the bath. Together, Eqs. 2, 3 and 4 describe completely the experimental setup illustrated in Figure 1(b).

We note that all three sets of equations are instantaneous: thermodynamic relations in Eq. 2—by its nature, and the heat flow equations Eq. 2, 3, by approximation that the heat conductance κint\kappa_{\mathrm{int}} and κext\kappa_{\mathrm{ext}} are constants, exhibiting no frequency dispersion in the experimental frequency range. We can therefore use a Fourier approach to analyze the response as a function of frequency of the driving field, ω\omega,

dH(t)=dH(ω)e−iωtdM(t)=dM(ω)e−iωtdS4f,lat(t)=dS4f,lat(ω)e−iωtdT4f,lat(t)=dT4f,lat(ω)e−iωt(5)\begin{aligned} dH(t)&=dH(\omega)e^{-i\omega t}\\ dM(t)&=dM(\omega)e^{-i\omega t}\\ dS^{4f,\mathrm{lat}}(t)&=dS^{4f,\mathrm{lat}}(\omega)e^{-i\omega t}\\ dT^{4f,\mathrm{lat}}(t)&=dT^{4f,\mathrm{lat}}(\omega)e^{-i\omega t} \tag*{(5)} \end{aligned}

to write a system of equations for frequency components, where the frequency components on the right-hand side of the equation are all complex functions of ω\omega:

[dS(ω)dM(ω)]4f=[CT0γγχ]4f[dT(ω)dH(ω)]4f\begin{bmatrix} dS(\omega) \\ dM(\omega) \end{bmatrix}^{4f} = \begin{bmatrix} \frac{C}{T_0} & \gamma\\ \gamma& \chi\end{bmatrix}^{4f} \begin{bmatrix} dT(\omega) \\ dH(\omega) \end{bmatrix}^{4f}
−iωT4fdS4f(ω)=−κint(dT4f(ω)−dTlat(ω))−iωTlatdSlat(ω)=κint(dT4f(ω)−dTlat(ω))−κext(dTlat(ω)−dTbath(ω))(6)\begin{aligned} -i\omega T^{4f}dS^{4f}(\omega) &= -\kappa_{\mathrm{int}}\left(dT^{4f}(\omega)-dT^{\mathrm{lat}}(\omega)\right) \\ -i\omega T^{\mathrm{lat}}dS^{\mathrm{lat}}(\omega) &= \kappa_{\mathrm{int}}\left(dT^{4f}(\omega)-dT^{\mathrm{lat}}(\omega)\right) \\ &\quad-\kappa_{\mathrm{ext}}\left(dT^{\mathrm{lat}}(\omega)-dT^{\mathrm{bath}}(\omega)\right) \tag*{(6)} \end{aligned}

Note that we assume the bath holds at constant temperature Tbath=T0T^{\mathrm{bath}}=T_0, dTbath(ω)=0dT^{\mathrm{bath}}(\omega)=0, and the temperature variation of each subsystem is much smaller than the total value (i.e. Tlat≈T0T^{\mathrm{lat}}\approx T_0, T4f≈T0T^{4f}\approx T_0, which is valid for considering the linear response.) Equation 6 is then a system of 4 equations for 4 unknowns (dT4f(ω)dT^{4f}(\omega), dTlat(ω)dT^{\mathrm{lat}}(\omega), dM4f(ω)dM^{4f}(\omega) and dS4f(ω)dS^{4f}(\omega)) which can be solved to find the physical quantities of interest. We will treat dH(ω)dH(\omega) as a constant-amplitude applied AC field, and dSlat(ω)dS^{\mathrm{lat}}(\omega) is completely defined by (Clat/Tlat)dTlat(ω)(C^{\mathrm{lat}}/T^{\mathrm{lat}})dT^{\mathrm{lat}}(\omega). Note also that dT4f(ω)dT^{4f}(\omega), dTlat(ω)dT^{\mathrm{lat}}(\omega), dM4f(ω)dM^{4f}(\omega) and dS4f(ω)dS^{4f}(\omega) are all complex quantities, with both an amplitude and a relative phase with respect to the driving AC magnetic field.

We can now calculate the two relevant response functions, the physical quantities that will be measured in experiments,

χAC(ω)=dM4f(ω)dH(ω),andΓAC(ω)=dTlat(ω)dH(ω)(7)\chi_{\mathrm{AC}}(\omega)=\frac{dM^{4f}(\omega)}{dH(\omega)}, \qquad\text{and} \qquad\Gamma_{\mathrm{AC}}(\omega)=\frac{dT^{\mathrm{lat}}(\omega)}{dH(\omega)} \tag*{(7)}

where χAC(ω)\chi_{\mathrm{AC}}(\omega) is the effective magnetic response of the experimental setup, and ΓAC(ω)\Gamma_{\mathrm{AC}}(\omega) is the effective magnetocaloric response measured through the lattice subsystem. Both of these response functions are defined via total (not partial) derivatives with respect to the driving field. Consequently, due to the internal thermal exchange process between the 4f and lattice subsystems, and the external relaxation between the lattice and the environment, both response functions differ from the intrinsic response of the magnetic ions defined by Eqn (2). Solving for χAC(ω)\chi_{\mathrm{AC}}(\omega) and ΓAC(ω)\Gamma_{\mathrm{AC}}(\omega) in Eq. 6, we obtain:

χAC(ω)=χ4f−T0(γ4f)2(iω)(κint+κext−Cl(iω))−κintκext+(iω)(Clκint+C4f(κint+κext))−C4fCl(iω)2(8)\chi_{\mathrm{AC}}(\omega)=\chi^{4f}-\frac{T_0(\gamma^{4f})^2(i\omega)(\kappa_{\mathrm{int}}+\kappa_{\mathrm{ext}}-C^{\mathrm{l}}(i\omega))}{-\kappa_{\mathrm{int}}\kappa_{\mathrm{ext}}+(i\omega)(C^{\mathrm{l}}\kappa_{\mathrm{int}}+C^{4f}(\kappa_{\mathrm{int}}+\kappa_{\mathrm{ext}}))-C^{4f}C^{\mathrm{l}}(i\omega)^2} \tag*{(8)}
ΓAC(ω)=−T0γ4fκint(iω)−κintκext+(C4f+Cl)κint(iω)+C4fκext(iω)−C4fCl(iω)2(9)\Gamma_{\mathrm{AC}}(\omega)=\frac{-T_0\gamma^{4f}\kappa_{\mathrm{int}}(i\omega)}{-\kappa_{\mathrm{int}}\kappa_{\mathrm{ext}}+(C^{4f}+C^{\mathrm{l}})\kappa_{\mathrm{int}}(i\omega)+C^{4f}\kappa_{\mathrm{ext}}(i\omega)-C^{4f}C^{\mathrm{l}}(i\omega)^2} \tag*{(9)}

The real and imaginary parts of χAC(ω)\chi_{\mathrm{AC}}(\omega) and ΓAC(ω)\Gamma_{\mathrm{AC}}(\omega) are plotted in Figure 1(c, Figure 1d) for parameter values closely matching the experiment performed on YbVO4_4. This corresponds to a scenario in which τintτext>1\frac{\tau_{\mathrm{int}}}{\tau_{\mathrm{ext}}}>1, which is ideal if one intends to determine the intrinsic τint\tau_{\mathrm{int}} in an experiment. Solutions corresponding to a wider set of parameter values are shown in Appendix § 5.2. Note that we have chosen to use a convention in which the complex numbers are formed following a positive sign: i.e. χAC=χAC′+iχAC′′\chi_{\mathrm{AC}}=\chi'_{\mathrm{AC}}+i\chi''_{\mathrm{AC}} and ΓAC=ΓAC′+iΓAC′′\Gamma_{\mathrm{AC}}=\Gamma'_{\mathrm{AC}}+i\Gamma''_{\mathrm{AC}}. 4 As we show below, both of these response functions are indeed observed in our measurements of YbVO4_4.

Seen on a Cole-Cole plot (right hand panel of Figure 1(c)), the magnetic response χAC(ω)\chi_{\mathrm{AC}}(\omega) follows a distorted semicircular path, exclusively in one quadrant (+,+)(+,+), with the external thermal relaxation determining the deviations from a perfect semi-circle at lower frequencies (right hand side of the distorted semicircle). For smaller values of τintτext\frac{\tau_{\mathrm{int}}}{\tau_{\mathrm{ext}}} the response evolves into two distinct semicircles (see Appendix § 5.2). In contrast, the magnetocaloric response ΓAC(ω)\Gamma_{\mathrm{AC}}(\omega) exhibits a full circle, inhabiting two quadrants, (+,+)(+,+) and (−,+)(-,+), independent of the value of τintτext\frac{\tau_{\mathrm{int}}}{\tau_{\mathrm{ext}}} (see Appendix § 5.2).

Looking at the real and imaginary parts of χAC(ω)\chi_{\mathrm{AC}}(\omega) and ΓAC(ω)\Gamma_{\mathrm{AC}}(\omega) in Figure 1(c) and (d) for the specific value of τintτext\frac{\tau_{\mathrm{int}}}{\tau_{\mathrm{ext}}} that is used and that corresponds to the observations, the peak in the real part of ΓAC(ω)\Gamma_{\mathrm{AC}}(\omega) occurs at approximately the same frequency as the maximum in the out of phase component of χAC(ω)\chi_{\mathrm{AC}}(\omega), and occurs at a frequency that reflects the geometric mean of the thermal relaxation times τint\tau_{\mathrm{int}} and τext\tau_{\mathrm{ext}}. This correspondence is more complicated for larger values of τintτext\frac{\tau_{\mathrm{int}}}{\tau_{\mathrm{ext}}}, as demonstrated in Appendix § 5.2.

AC magnetic susceptibility

Several aspects of the AC magnetic susceptibility deserve additional commentary before we proceed with a description of the experiment.

First, as noted above, χAC(ω)\chi_{\mathrm{AC}}(\omega) differs from the intrinsic magnetic susceptibility of the 4f subsystem χ4f\chi^{4f}, because the system shares energy between the two subsystems and with the thermal bath. Assuming that the intrinsic spin susceptibility χ4f\chi^{4f} has no frequency dependence, the measured response χAC(ω)\chi_{\mathrm{AC}}(\omega) obtains all of its frequency dependence through interaction with other subsystems and/or the thermal bath. In this case, the zero frequency (isothermal) value of χAC(ω)=χ4f\chi_{\mathrm{AC}}(\omega)=\chi^{4f}, and χAC(ω)\chi_{\mathrm{AC}}(\omega) fully describes the frequency dependence of the magnetic response. However, technically this does not have to be the case, and χ4f\chi^{4f} can in principle have an intrinsic frequency dependence (for example, in the limit ω→∞\omega\to\infty, the inertia of the electrons ultimately limits their ability to respond to the driving field). For the modest frequency regimes considered here, however, such effects are irrelevant, and the intrinsic value χ4f\chi^{4f}, defined in (2), can be safely assumed to be independent of frequency.

Second, we note that Eq. (8) naturally yields the familiar Debye relaxation [1] when considered in a limit that a single relaxation dominates. It is well known that when a single relaxation time τ\tau governs the periodic flow of energy in a system, the dynamical susceptibility as a function of driven frequency ω\omega is given by a Debye relaxation process [1]: χ(ω)=χT+1kiωτ1−iωτ\chi(\omega)=\chi_T+\frac{1}{k}\frac{i\omega\tau}{1-i\omega\tau}, where χT\chi_T is the isothermal susceptibility (the zero frequency value), and the high-frequency value (often referred to as the adiabatic susceptibility) χS=χT−1k\chi_S=\chi_T-\frac{1}{k} (i.e. 1k\frac{1}{k} is the difference between the susceptibility measured at zero frequency and infinite frequency5{}^{5}). When the material is decoupled from the external bath (in the limit κext→0\kappa_{\mathrm{ext}}\to0), Equation 8 reduces to:

χAC(ω)=χ4f−T0(γ4f)2Cl+C4f11−iωτint+T0(γ4f)2C4fiωτint1−iωτint(10)\chi_{\mathrm{AC}}(\omega)=\chi^{4f}-\frac{T_0(\gamma^{4f})^2}{C^l+C^{4f}}\frac{1}{1-i\omega\tau_{\mathrm{int}}}+\frac{T_0(\gamma^{4f})^2}{C^{4f}}\frac{i\omega\tau_{\mathrm{int}}}{1-i\omega\tau_{\mathrm{int}}} \tag*{(10)}

If we take the limit Cl→∞C_l\to\infty such that the lattice acts as a thermal bath for the spins, this further reduces to the standard Debye form

χAC(ω)=χ4f+T0(γ4f)2C4fiωτint1−iωτint(11)\chi_{\mathrm{AC}}(\omega)=\chi^{4f}+\frac{T_0(\gamma^{4f})^2}{C^{4f}}\frac{i\omega\tau_{\mathrm{int}}}{1-i\omega\tau_{\mathrm{int}}} \tag*{(11)}

The isothermal, DC, limit is clearly given by χ4f\chi^{4f}, the intrinsic susceptibility of the 4f subsystem. Meanwhile, the adiabatic limit is given by χS=χ4f−T0(γ4f)2C4f\chi_S=\chi^{4f}-\frac{T_0(\gamma^{4f})^2}{C^{4f}}. An alternative, but ultimately equivalent derivation of this result is given in Appendix D.

Finally, we note that the thermal model that we have developed is only applicable in the absence of significant thermal gradients. Care must be taken to closely match these conditions. This effect is explored in § 2 below, in which we describe how optimal thermal conditions can be achieved and experimentally verified.

AC magnetic response of YbVO4

The above insights indicate that the thermal response of a material cannot, and indeed must not, be neglected in the measurement of the magnetic response at finite frequency. This motivates a more careful investigation of the cross-relaxation that occurs in AC susceptibility experiments, and that we demonstrate explicitly here for YbVO4\mathrm{YbVO}_{4}.

We start by measuring χAC(ω)\chi_{AC}(\omega) for a single crystal of YbVO4\mathrm{YbVO}_{4} mounted using different methods, with the aim of demonstrating an important point, namely that the measured value can depend on the experimental configurations that are used, even when internal relaxation processes dominate the quasi-adiabatic response.

To illustrate the effects of extrinsic factors that indirectly affect the measured χAC(ω)\chi_{AC}(\omega) of YbVO4\mathrm{YbVO}_{4}, we first compare the magnetic relaxation behavior for the same crystal mounted using three different configurations, illustrated respectively in panels (a), (b) and (c) of Figure 2. In the first case of end-contact (panel (a), red data points), the sample’s extrinsic thermal contact is minimized on both ends using Low-Temperature GE Varnish and Teflon materials with relatively low thermal conductivity at low temperatures. In this configuration, the long axis of the sample exceeds the characteristic thermal length scale for all frequencies considered, and large temperature inhomogeneities can be anticipated. In the second case of the single-sided mounting condition (panel (b), blue data points), the sample has one complete face connected to the sample holder via GE Varnish. This is consistent with the standard procedure recommended by the MPMS system vendor, but still risks some degree of thermal inhomogeneity if the sample thickness is close to the characteristic thermal length scale. In the third case, the extrinsic thermal contact is maximized by encapsulating the sample between two quartz surfaces (panel (c), yellow data points), and providing the best approximation to an isothermal environment. Figure 2(d,Figure 2e) plots the measured response χAC(ω)\chi_{AC}(\omega) as a function of frequency for all three mounting configurations.

Sample mounting configurations and AC susceptibility data

Figure 2. Data illustrating how sample mounting configurations can affect AC magnetic relaxation. Panel (a-c) illustrates three different sample mounting configurations, described in the main text. Colored bars represent the sample that is to be measured, together with its dimensions. The same sample of YbVO4_4 is used for all three configurations to enable direct comparison. Grey blocks indicate quartz platforms that serve as heat baths, or at least thermal connection to a larger heat bath. The sample is oriented with the magnetic field aligned along the long c-axis of the crystal (horizontal in the schematic diagrams). AC susceptibility measurements were made at 3 K, 0.1 T, using an AC field of 3 Oe. Panels (d) and (e) show the real (χAC′\chi^\prime_{\mathrm{AC}}) and imaginary parts (χAC′′\chi^{\prime\prime}_{\mathrm{AC}}) normalized by χT\chi_T, which was determined from fits to the Debye model. Panel (f) shows the associated Cole-Cole plot in which frequency is an implicit variable. Data are shown for the three mounting configurations, using the same colors to differentiate the three configurations. Solid lines in (d,e,f) are fit results based on Eq. (11). The encapsulated configuration (yellow data points) yields data that are closest to the idealized Debye relaxation conditions.

Inspection of the data shown in Figure 2 reveals that the adiabatic (high frequency limit) and isothermal (low frequency limit) susceptibilities are independent of the extrinsic mounting configuration. Similarly, the magnitude of the excitation field does not affect the adiabatic and isothermal response (we varied the amplitude of the driven field between 1 Oe and 10 Oe, finding that this did not affect the result). Nevertheless, the way that the sample is mounted clearly affects the measured susceptibility, including the frequency at which the imaginary part of the response has its maximum value, and the overall shape of the response as a function of frequency.

To further visualize the relaxation behavior, the real part of the χAC(ω)\chi_{AC}(\omega) is plotted against its imaginary part as a Cole-Cole plot in Figure 2(f). Under uniform magnetic and thermal conditions, and in the limit of there being a single characteristic relaxation time in the measured frequency range, the response plotted in this way should be described by a perfect semicircle with an aspect ratio of 1, where frequency is the implicit variable. As described in Section III, including separate internal and external thermal relaxation leads to deviations from a perfect semicircle (see Appendix § 5.2), but with only small

deviations occurring in the low frequency regime for cases where τint/τext>1\tau_{int}/\tau_{ext} > 1. Significantly, the data obtained from the end-contacted method (red data points) deviate from a semi-circle over the entire frequency range. In contrast, the data obtained from the single-sided and encapsulated techniques (blue and yellow data points respectively) deviate progressively less dramatically from a perfect semi-circle, with the closest to semicircular behavior being obtained for the encapsulated technique.

We emphasize that deviations from a Debye-like response as reflected by a semi-circular shape on a Cole-Cole plot cannot be fit by the model described in Section III and hence indicate significant thermal anisotropy. This deviation is particularly prominent for the end-contacted method (red data points). Such a mounting condition is inappropriate for determining the intrinsic susceptibility of the material and/or the associated intrinsic thermal relaxation times. Similarly, the presence of an almost perfect semicircular response for the encapsulated (yellow data points) method does not necessarily imply that there is only one relaxation time. With reference to Appendix § 5.2, such an observation simply implies that τint>τext\tau_{int} > \tau_{ext} and/or that low enough frequencies, and/or sensitive enough measurements, are not able to distinguish the subtle deviations from perfect semicircular behavior that are present when internal and external relaxation are both present.

Importantly, we emphasize that the optimal mounting configuration is not necessarily one that minimizes thermal contact with the environment (end contacted example in this case), but rather is one that leads to the most uniform thermal conditions in the sample (fully encapsulated example in this case). Identifying the optimized thermal condition enables us to proceed with conducting quantitative analysis of the cross-relaxation affecting the magnetic and thermal response of the material in question. We use this experimental configuration for the subsequent analysis described in Section VII.

AC magnetocaloric response of YbVO4

MCE measurements were performed following the procedures described in Section II. An AC field of 3 Oe was used. In order to ensure meaningful comparison of MCE and susceptibility measurements, the same sample, and the same mounting configuration (corresponding to the yellow configuration shown in Figure 2), were used for both measurements. Following the discussion in Section III, the response function ΓAC(ω)\Gamma_{AC}(\omega) is measured, and reported in Figure 3 together with χAC(ω)\chi_{AC}(\omega). In both cases, data were obtained over the same frequency range at a temperature of 3 K for magnetic fields between 0 and 1 T.

Experimental results for YbVO4 showing the frequency dependence of the real and imaginary parts of the response functions

Figure 3. Experimental results for YbVO4_4 showing the frequency dependence of the real (upper panels) and imaginary (lower panels) parts of the response functions χAC(ω)\chi_{\rm AC}(\omega) (in panels (a,b)) and ΓAC(ω)\Gamma_{\rm AC}(\omega) (in panels (c,d)). Data are shown for representative DC magnetic fields from 0 T to 1 T. All data were taken at a temperature of 3 K.

Before performing detailed fits to the data based on the thermal model, we first note three observations that are evident simply by inspecting the data shown in Figure 3. First, the data clearly follow the anticipated functional forms sketched in Figure 1(c, Figure 1d). Second, there is clearly a strong field dependence to both quantities, as anticipated for YbVO4_4 due to Zeeman splitting of the CEF eigenstates. And third, the field-dependence is very similar for the two quantities; i.e. the maximum in the real part of ΓAC(ω)\Gamma_{\rm AC}(\omega) follows the same trend as the maximum in the imaginary part of χAC(ω)\chi_{\rm AC}(\omega). The consistency in the shift of the characteristic frequency between the two measurements implies that the same internal and extrinsic heat transfer processes are being captured in both experiments.

We note that the strong frequency dependence is not due to external relaxation. Similar measurements were performed for the closely related isotropic material GdVO4_4, a material for which phonon bottleneck effects are not anticipated due to the absence of CEF effects. These measurements (see Appendix § 4) did not reveal a strong frequency dependence, even when the GdVO4_4 sample was held under similar experimental conditions (i.e. similar external thermal relaxation). Thus, the relaxation effects evident in Figure 3 point to an intrinsic internal slow relaxation, as anticipated for YbVO4_4, with the anticipated strong field dependence.

Nevertheless, as the fitting procedure described below reveals, the external relaxation must still be considered in order to obtain a complete quantitative description of the experiment, which is the main point of this paper and of our analysis. Indeed, with multiple possible relaxation processes, one cannot formally identify the physical origin of the relaxation from susceptibility measurements alone (i.e. (11) would equally well describe the susceptibility if the lattice were perfectly thermally coupled to the 4f subsystem, but thermal relaxation to an external bath dominated the dynamics).

Fits to the thermal model

We now perform fits to measured response functions χAC(ω)\chi_{\rm AC}(\omega) and ΓAC(ω)\Gamma_{\rm AC}(\omega) shown in Figure 3 to obtain the field dependence of τint\tau_{\rm int} and τext\tau_{\rm ext}.

Since the observed magnetic response is so closely approximated by a single relaxation time (i.e. the Cole-Cole plot is indistinguishable from a semicircle for the range of frequencies that we have available), we use the simplified Debye relaxation described by (11) to extract a single relaxation time, τχ\tau_\chi. As we will see, this value closely approximates τint\tau_{\rm int} obtained from MCE measurements, consistent with the expectation that τint>τext\tau_{\rm int} > \tau_{\rm ext}, and consequently can also be used in a global fit of both data sets. Both approaches were taken, such that we obtained a value τχ\tau_\chi from just the magnetic response, and a value for τint\tau_{\rm int} from a global fit to both the magnetic and caloric response.

For the MCE data, two relaxation times are required to fit the data, corresponding to τint\tau_{\rm int} and τext\tau_{\rm ext}.

To simplify the fitting procedure, we define parameters η=Cl/C4f\eta= C_l/C_{4f}, r=(T0(γ4f2))/κintr = (T_0(\gamma_{4f}^2))/\kappa_{\rm int}, and Q=T0γ4fη/(κint(1+η))Q = T_0\gamma_{4f}\eta/(\kappa_{\rm int}(1+\eta)), where the magneticocaloric coefficient defined in (2). Rewriting the four fitting equations after substitution of the redefined fitting parameters to (11) and 9 yields the following useful reparameterizations:

χAC′(ω)=χ−B+B1+τint2ω2\chi'_{\rm AC}(\omega) = \chi- B + \frac{B}{1+\tau_{\rm int}^{2}\omega^{2}}
χAC′′(ω)=Bτintω1+τint2ω2(12)\chi''_{\rm AC}(\omega) = \frac{B\tau_{\rm int}\omega}{1+\tau_{\rm int}^{2}\omega^{2}} \tag*{(12)}
ΓAC′(ω)=−Q(1+η)τext(τext+τint)ω2τint(η2+(1+η)((1+η)τext2+2τextτint+(1+η)τint2)ω2+(1+η)2τext2τint2ω4)(13)\Gamma'_{\rm AC}(\omega) = \frac{-Q(1+\eta)\tau_{\rm ext}(\tau_{\rm ext}+\tau_{\rm int})\omega^{2}}{\tau_{\rm int}\left(\eta^{2}+(1+\eta)\left((1+\eta)\tau_{\rm ext}^{2}+2\tau_{\rm ext}\tau_{\rm int}+(1+\eta)\tau_{\rm int}^{2}\right)\omega^{2}+(1+\eta)^{2}\tau_{\rm ext}^{2}\tau_{\rm int}^{2}\omega^{4}\right)} \tag*{(13)}
ΓAC′′(ω)=rQτextω(η−(1+η)τextτintω2)τint(η2+(1+η)((1+η)τext2+2τextτint+(1+η)τint2)ω2+(1+η)2τext2τint2ω4)(14)\Gamma''_{\rm AC}(\omega) = \frac{rQ\tau_{\rm ext}\omega\left(\eta-(1+\eta)\tau_{\rm ext}\tau_{\rm int}\omega^{2}\right)}{\tau_{\rm int}\left(\eta^{2}+(1+\eta)\left((1+\eta)\tau_{\rm ext}^{2}+2\tau_{\rm ext}\tau_{\rm int}+(1+\eta)\tau_{\rm int}^{2}\right)\omega^{2}+(1+\eta)^{2}\tau_{\rm ext}^{2}\tau_{\rm int}^{2}\omega^{4}\right)} \tag*{(14)}

Global fits of both data sets to Eq. (12) and Eq. 13 yield the fits shown by dashed lines in Figure 4 panels (a) and (b). The fits accurately capture the observed response for both χAC(ω)\chi_{\mathrm{AC}}(\omega) and ΓAC(ω)\Gamma_{\mathrm{AC}}(\omega), implying that we have identified the appropriate thermal model, and that fit parameters can be meaningfully extracted.

Three-panel Cole-Cole plots and characteristic relaxation times

Figure 4. Fitting of the two measured response functions χAC(ω)\chi_{AC}(\omega) and ΓAC(ω)\Gamma_{AC}(\omega) for YbVO4 using Eqn.s 12 and 13. All data were measured at 3K. (a) A Cole-Cole plot showing the imaginary (χAC′′)(\chi''_{AC}) against the real (χAC′)(\chi'_{AC}) part of the dynamical susceptibility. (b) A similar plot for the AC MCE response, ΓAC(ω)\Gamma_{AC}(\omega). (c) The characteristic relaxation times (τχ,τint(\tau_{\chi}, \tau_{int} and τext)\tau_{ext}) obtained from the fits, as described in the main text. See Appendix G for other fitted parameters.

Nevertheless, inspection of Figure 4(b) reveals a slightly non-circular MCE response on the Cole-Cole plot. Such an effect can be caused by external factors not captured by the simplified model here, such as the heat exchange between the material and the thermometer (see Appendix § 5.1). To account for this, we include a prefactor rr to ΓAC′′(ω)\Gamma_{\mathrm{AC}}^{\prime\prime}(\omega) in Eq. 13, which is treated as empirical ‘non-circular’ parameter in the associated fits.

The field dependence of the two time constants that are extracted from these fits is shown in Figure 4 (c). The red data points show the results for τint\tau_{\mathrm{int}} when both χAC(ω)\chi_{\mathrm{AC}}(\omega) and ΓAC(ω)\Gamma_{\mathrm{AC}}(\omega) are simultaneously fit by the full thermal model involving two time constants. Yellow data points show the associated τext\tau_{\mathrm{ext}} values from those same fits to the full thermal model. In order to confirm that the combination fitting method is valid, we also fit the measured χAC(ω)\chi_{\mathrm{AC}}(\omega) separately using only Eq. (12). Blue data points in Figure 4(c) show the result from fitting χAC(ω)\chi_{\mathrm{AC}}(\omega) using only a single-time constant denoted as τχ\tau_{\chi}. We find that the fitted τext\tau_{\mathrm{ext}} relaxes much faster than τint\tau_{\mathrm{int}}, implying that τint/τext>1\tau_{\mathrm{int}}/\tau_{\mathrm{ext}} > 1 is satisfied here, as previously mentioned in Section III. This is also consistent with the close agreement between τint\tau_{\mathrm{int}} and τχ\tau_{\chi}, which demonstrates that the two experiments capture the same energy transfer processes, and that the intrinsic internal time constant dominates in this case.

The focus of this paper is on developing the experimental technique of AC MCE and the associated thermal model. Nevertheless, we comment briefly on quantitative aspects of the experimental result specific to YbVO4_4. First, the derived values for τint\tau_{\mathrm{int}} are consistent with typical values found for other similar materials with strong magnetic anisotropy [2]. More interestingly, as we show in Appendix G, we find that the field dependence follows an exponential relationship, indicating that the Zeeman splitting of the CEF eigenstates plays a significant role in determining τint\tau_{\mathrm{int}}. (Indeed, following Orbach’s analysis [2], this indicates that the Debye temperature of YbVO4_4 is larger than the CEF splitting, as indicated schematically in Figure 1.) And finally, relative to the strong field-dependence of τint\tau_{\mathrm{int}}, τext\tau_{\mathrm{ext}} exhibits a much smaller variation with field. The physical origin of this small field-dependence presumably reflects a field-induced change in κext\kappa_{\mathrm{ext}}, but this would need to be checked by separate measurements of the field-dependence of the thermal conductivity of YbVO4_4.

Despite the quantitative success of the thermal model in describing the observed response functions, nevertheless there are subtle deviations from the anticipated behavior. In particular, the MCE data shown in Figure 4(b) deviate slightly from a perfect circle (captured by the prefactor rr in Eqn. 13) and also reveal a subtle ’kink’, that is most evident for higher field data. Empirically, this kink is found to be sensitive to the way in which the thermal sensor is attached to the sample (see Appendix § 5.1). Since this has only a modest effect for the present experiment, for clarity and simplicity we explicitly neglect including the thermal sensor in the thermal model that we have developed and that is captured by Eqn. (9) and Eqn. 13. However, as discussed in Appendix § 5.1, it is relatively simple to include this as an additional discrete element in the thermal model if needed (i.e. if heat flow between the lattice and the thermal sensor is a significant factor).

We close this section by commenting on the fit to the magnetic response, χAC(ω)\chi_{\mathrm{AC}}(\omega). For cases where the external relaxation time is considerably smaller than the internal one (such as this case) χAC(ω)\chi_{\mathrm{AC}}(\omega) follows an almost semi-circular form on a Cole-Cole plot (see Appendix § 5.2). Consequently, Eq. (8) cannot be used to separately determine the internal and external time constants, and instead, as we have done, one must use the simplified Eq. (11). Generally speaking, although Debye-like relaxation behavior obtained from the magnetic response can be fitted with a simplified (single relaxation time) model, the interpretation of the time constant that is obtained from such a fit could be incomplete or even misleading unless the corresponding AC MCE measurement identifies the relation between the time constants. In particular, taken on its own, it is not even evident if the obtained time constant is due to internal or external relaxation. The MCE result must be considered in parallel in order to reveal the complete thermal exchange process.

Discussion

It is instructive to consider the relation between the thermal analysis that we present above to a generalized linear response theory [26, 27]. When multiple variables interact with each other in a circuit, the overall relaxation behavior is characterized by a set of thermodynamic conjugate variables, which refer to pairs of “force” (fωf_{\omega}) and “displacement” (xi(ω)x_i(\omega)) that respond directly to each other. A change in one variable directly affects the other. The application of “forces” results in a corresponding “displacement” that characterizes the linear response function αi(ω)\alpha_i(\omega):

xi(ω)=αi(ω)fω(15)x_i(\omega) = \alpha_i(\omega) f_{\omega} \tag*{(15)}

The most commonly existing pair of conjugate variables is temperature and entropy (T,ST,S). When the thermodynamic state of a closed system remains unchanged by applied fields, the thermal-susceptibility is uniquely defined by the heat capacity because dS=(Cp/T)dT\mathrm{d}S = (C_p/T)\mathrm{d}T. Consequently, the dynamical response is completely determined by the rate of thermal conductance, affected by an external heat source. If, however, the system develops a caloric response, it must imply that another pair of conjugate variables exists in at least one of the circuit components. For example, the measurement results above contain 3 pairs of conjugate variables, which are (H,M)(H, M), (T4f,S4f)(T^{4f}, S^{4f}) and (Tlat,Slat)(T^{lat}, S^{lat}). Consequently, the full relaxation behavior can be completely determined by a linear response matrix:

(MT4fTlat)=(α11α12α13α21α22α23α31α32α33)(HS4fSlat)\begin{pmatrix} M \\ T^{4f} \\ T^{lat} \end{pmatrix} = \begin{pmatrix} \alpha_{11} & \alpha_{12} & \alpha_{13} \\ \alpha_{21} & \alpha_{22} & \alpha_{23} \\ \alpha_{31} & \alpha_{32} & \alpha_{33} \end{pmatrix} \begin{pmatrix} H \\ S^{4f} \\ S^{lat} \end{pmatrix}

The diagonal terms represent the susceptibility response. α11\alpha_{11} is the AC magnetic susceptibility (χAC(ω)(\chi_{AC}(\omega) in Eq. (8)), α22\alpha_{22} accounts for the thermal susceptibility of the spin affected by the magnetic field, and α33\alpha_{33} accounts for thermal susceptibility of the lattice. From an experimental perspective, we note that any conventional dynamical measurement only obtains the frequency response function of the diagonal matrix element. Although all matrix elements must satisfy the relation of αi,i+jαi+j,i=αi,iαi+j,i+j\alpha_{i,i+j}\alpha_{i+j,i} = \alpha_{i,i}\alpha_{i+j,i+j}, the matrix cannot be uniquely defined by dynamical susceptibility only. Furthermore, the term α33\alpha_{33} is special in the sense that it is a single positive real constant Cl/T0C^{l}/T_{0} instead of a complex response function. The AC caloric effect function ΓAC(ω)\Gamma_{AC}(\omega) described in this paper can be associated with α13\alpha_{13} by the relation ΓAC(ω)=α13/α33\Gamma_{AC}(\omega) = \alpha_{13}/\alpha_{33}.

The matrix response shown above provides an illustrative example that any dynamical behavior of a non-instantaneous magnetic response is most likely to be the complex result of both internal structure and external conditions. Hence, for systems that are composed of multiple degrees of freedom, the measured χAC(ω)\chi_{AC}(\omega) on its own is insufficient to reflect the complete dynamical process. The discretized thermal model based on spin-lattice relaxation underscores the importance of measuring the AC caloric response as a reciprocal observation to provide complementary information to any susceptibility analysis.

Finally, we note that a natural extension of the above analysis is to also consider elastocaloric responses, where the ‘force’ and ‘displacement’ terms literally correspond to components of the stress and strain tensor, the diagonal terms in the linear response matrix correspond to terms in the elastic stiffness tensor, and the off-diagonal terms correspond to the elastocaloric response.

Summary

We have developed an experimental method to measure the AC MCE, and have introduced a discretized thermal analog circuit approach that fully describes the cross-relaxation between magnetization and temperature in the frequency domain in the presence of an AC magnetic field excitation. This approach permits a full understanding of the frequency dependence of the AC susceptibility χAC(ω)\chi_{AC}(\omega) and the AC MCE ΓAC(ω)\Gamma_{AC}(\omega) through the presence of both extrinsic and intrinsic relaxation processes.

We demonstrated the technique and the associated fitting methods using YbVO4, a material for which there are slow magnetization dynamics at low temperatures. arising from a phonon-bottleneck effect, with a strong field dependence.

The magnetic dynamics of a wide variety of materials are often inferred from just susceptibility measurements, and analysed using a Debye, or closely related, model. Associated slow dynamics can be attributed to various physical effects. While these analyses are well-motivated, they are necessarily incomplete if cross-relaxation is neglected, potentially missing or mis-characterizing important new material-specific insights. The new caloric approach developed in this paper could provide additional evidence about these internal relaxation phenomena, while also providing a grounded description of the accompanying thermal relaxation effects associated with extrinsic effects. We expect that the approach we have outlined here will prove helpful in future studies of magnetic dynamics in a wide range of materials.

Acknowledgements

We thank Matthias S. Ikeda for fruitful discussions and original insights on the AC caloric measurement techniques. Low-temperature measurements performed at Stanford University were supported by the Air Force Office of Scientific Research Award FA9550-24-1-0357, using a cryostat acquired with award FA9550-22-1-0084. Crystal-growth experiments were supported by the Gordon and Betty Moore Foundation Emergent Phenomena in Quantum Systems Initiative Grant GBMF9068. Work at Los Alamos National Laboratory is supported by the NSF through DMR-1644779 and DMR-2128556, the U.S. Department of Energy, and the DOE/BES “Science of 100 T” grant. M.P.Z. was also partially supported by a National Science Foundation Graduate Research Fellowship under grant number DGE-1656518. L.Y. acknowledges support from the Marvin Chodorow Postdoctoral Fellowship at the Department of Applied Physics, Stanford University.

Experimental set up of the AC MCE measurement

We employ a RuOx_x thin film resistor as the thermal sensor. The sensor is mounted directly on the sample and connected to a Wheatstone bridge, comprising three other identical RuOx_x resistors (Figure 5(a)). The resistance of the sensor is measured using an AC current, with a drive frequency ωc∼3137\omega_c \sim3137 Hz. The magnetic field is modulated at a fixed frequency ωm\omega_m, with values between 0.1 and 1000 Hz. Using a dual-frequency lock-in technique, we demodulate the signal to obtain the amplitude and relative phase of the thermally-driven changes in resistance of the RuOx_x sensor.

AC MCE probe assembly and circuit diagram

Figure 5. (a) Photograph of an AC MCE probe assembly, with inset showing a magnified image of the thermal sensor (RxR_x; the small black chip in the image) mounted on the crystal of YbVO₄ (yellow color prism) which is mounted on a flattened section of a thin quartz rod (clear). The sample is located at the end of the quartz rod, which is attached to the ETO probe head. Before measurement, the center of the sample is aligned with the center of the applied magnetic coils following standard procedures. (b) Circuit diagram of the AC MCE measurement. Here, RxR_x represents the thermal resistor. R1R_1, R2R_2, and R3R_3 are bridge resistors. The raw temperature oscillation signal is obtained from the bridge voltage VbV_b via a lock-in amplifier in a dual mode with its internal reference, and external reference from the magnetic coil (VhV_h). A second lock-in amplifier measures VxV_x to obtain the temperature profile of the thermal resistors. A Voltage Controlled Current Source converts the 1 V voltage output of the lock-in amplifier to an excitation current of 100 μ\muA to the Wheatstone Resistor Bridge.

The circuit diagram is shown in (Figure 5(b)). We use a Stanford Research SR860 lock-in amplifier operating in dual mode to measure the bridge voltage VbV_b (proportional to the change in resistance of the RuOx_x sensor, from which the amplitude and phase of the temperature oscillations of the thermal sensor are deduced), and another SR860 operating in external mode to measure the actual resistance of the VsV_s (from which the average temperature of the sample is deduced). The amplified driven coil signal gives an additional isolated output via the Electronic Module of the MPMS System. The voltage output with the internal reference frequency of the first lock-in was amplified into a current signal via a Stanford Research CS580 Voltage Controlled Current Source and also gave the reference signal input of the second lock-in. The Electron Transport Option (ETO) probe provided by the MPMS accessory kits was applied to enable transport measurement.

Several aspects of the circuit and the operation of the dual mode lock in amplifier deserve a more detailed commentary.

Obtaining the amplitude of temperature oscillations

In an AC MCE measurement, we convert the amplitude signal VSR860=Xout2+Yout2V_{SR860} = \sqrt{X_{out}^{2} + Y_{out}^{2}} to the actual temperature signal recorded by the sensor. In the circuit diagram shown in Figure 5(b), a change of resistance ΔR\Delta R is detected by RxR_x. The bridge voltage VbV_b is defined as the peak-to-peak value, therefore it is 2 times the value of VSR860V_{SR860} reported from the electronics [28]:

Vb=2VSR860Ib=2IR(16)\begin{aligned} V_b &= 2V_{SR860} \\ I_b &= 2I_R \tag*{(16)} \end{aligned}

According to the property of the Wheatstone bridge, we have:

Vb=−V(R+ΔR)2R+VR2R=−VΔR2R(17)\begin{aligned} V_b &= -\frac{V(R+\Delta R)}{2R} + \frac{VR}{2R} \\ &= -\frac{V\Delta R}{2R} \tag*{(17)} \end{aligned}

By knowing the characteristic R−TR-T curve of the thermoresistor, the value of the temperature derivative can be obtained from a polynomial curve fitting method. Therefore, the value of dRdT\frac{dR}{dT} is well-defined at each temperature. We calculate the change of temperature ΔT\Delta T as:

ΔT=−ΔR/(dRdT)=−4VSR860Ib/(dRdT)(18)\begin{aligned} \Delta T &= -\Delta R/\left(\frac{dR}{dT}\right) \\ &= -\frac{4V_{SR860}}{I_b}\left/\left(\frac{dR}{dT}\right)\right. \tag*{(18)} \end{aligned}

Finally, the response function ΓAC(ω)\Gamma_{AC}(\omega) is experimentally obtained by ΓAC(ω)=ΔT(ω)/ΔH\Gamma_{AC}(\omega) = \Delta T(\omega)/\Delta H.

Determining the relative phase of the temperature oscillations

It is worth noting that the phase measured in the dual-frequency mode of SR860 depends on the choice of the internal reference frequency. Specifically, swapping the internal and external references flips the sign of the phase. As an example, consider a modulated signal in the form

Vsig(t)=sin⁡(ωct)(1+δVsin⁡(ωmt+ϕm))(19)V_{\mathrm{sig}}(t)=\sin(\omega_c t)(1+\delta V\sin(\omega_m t+\phi_m)) \tag*{(19)}

with the carrier frequency fc=2πωcf_c=2\pi\omega_c and the modulation frequency ωm\omega_m.

If the internal frequency is set to ωc\omega_c and an external reference passed in at fm=2πωmf_m=2\pi\omega_m, then the SR860 multiplies the signal by XLIA=2sin⁡((ωc−ωm)t)X_{\mathrm{LIA}}=\sqrt{2}\sin((\omega_c-\omega_m)t) in Channel X and by YLIA=2cos⁡((ωc−ωm)t)Y_{\mathrm{LIA}}=\sqrt{2}\cos((\omega_c-\omega_m)t) in Channel Y [28], leading to the outputs:

Xc=2sin⁡((ωc−ωm)t)sin⁡(ωct)(1+δVsin⁡(ωmt+ϕm))=δV22sin⁡(ϕm)+⋯Yc=2cos⁡((ωc−ωm)t)sin⁡(ωct)(1+δVsin⁡(ωmt+ϕm))=δV22cos⁡(ϕm)+⋯(20)\begin{aligned} X_c&=\sqrt{2}\sin((\omega_c-\omega_m)t)\sin(\omega_c t)(1+\delta V\sin(\omega_m t+\phi_m))\\ &=\frac{\delta V}{2\sqrt{2}}\sin(\phi_m)+\cdots\\ Y_c&=\sqrt{2}\cos((\omega_c-\omega_m)t)\sin(\omega_c t)(1+\delta V\sin(\omega_m t+\phi_m))\\ &=\frac{\delta V}{2\sqrt{2}}\cos(\phi_m)+\cdots \tag*{(20)} \end{aligned}

where “…” include the oscillating terms that are filtered out. On the other hand, if the internal reference is at fmf_m and the external reference at fcf_c, then XLIAX_{\mathrm{LIA}} acquires a minus sign while YLIAY_{\mathrm{LIA}} remains the same. Therefore, the outputs become:

Xm=2sin⁡((ωm−ωc)t)Vsig(t)=−δV22sin⁡(ϕm)+⋯=−XcYm=2cos⁡((ωm−ωc)t)Vsig(t)=δV22cos⁡(ϕm)+⋯=Yc(21)\begin{aligned} X_m&=\sqrt{2}\sin((\omega_m-\omega_c)t)V_{\mathrm{sig}}(t)=-\frac{\delta V}{2\sqrt{2}}\sin(\phi_m)+\cdots\\ &=-X_c\\ Y_m&=\sqrt{2}\cos((\omega_m-\omega_c)t)V_{\mathrm{sig}}(t)=\frac{\delta V}{2\sqrt{2}}\cos(\phi_m)+\cdots\\ &=Y_c \tag*{(21)} \end{aligned}

and the measured phase is complex conjugate to the previous case.

In the case where fint=fmf_{\mathrm{int}}=f_m, outputs XmX_m and YmY_m are rotated by 90∘90^\circ compared to the typical measurements locked into a single frequency. In the other case where fint=fcf_{\mathrm{int}}=f_c (e.g. Figure 5), outputs XcX_c and YcY_c swap X and Y channels, hence equivalent to an extra conjugation after the rotation. We have verified this reference-dependence of phase in DUAL mode with a daisy-chain experiment: in place of the Dual mode lock-in (LIA#1 in Figure 5), we demodulated the signal with a lock-in at ωc\omega_c first, and then fed its X channel output to a second lock-in at ωm\omega_m. Swapping the X and Y outputs form the second lock-in gave us back the measurements done in Dual mode with fint=fcf_{\mathrm{int}}=f_c, as expected.

CEF eigenstates and spin-lattice relaxation in YbVO₄

The CEF levels are eigenstates of the Hamiltonian:

HCEF=B20O20+B40O40+B44O44+B60O60+B64O64(22)H_{\mathrm{CEF}}=B_2^0O_2^0+B_4^0O_4^0+B_4^4O_4^4+B_6^0O_6^0+B_6^4O_6^4 \tag*{(22)}

where BnmB_n^m are the CEF parameters defined by the RVO₄ lattice for Yb³⁺ ions in D2dD_{2d} point symmetry, and OnmO_n^m are the standard Steven operators. The irreducible representations of the ground-state, first and second excited states calculated for the Yb³⁺ ion with these crystal field parameters [29] are:

±Γ17=0.901∣±72⟩−0.433∣∓12⟩, E=0 meV\pm\Gamma_1^7=0.901\left|\pm\frac{7}{2}\right\rangle-0.433\left|\mp\frac{1}{2}\right\rangle,\ E=0\ \mathrm{meV}
±Γ61=±0.886∣±32⟩∓0.464∣∓52⟩, E=7.2 meV\pm\Gamma_6^1=\pm0.886\left|\pm\frac{3}{2}\right\rangle\mp0.464\left|\mp\frac{5}{2}\right\rangle,\ E=7.2\ \mathrm{meV}
±Γ27=0.433∣±72⟩+0.901∣∓12⟩, E=34.8 meV(23)\pm\Gamma_2^7=0.433\left|\pm\frac{7}{2}\right\rangle+0.901\left|\mp\frac{1}{2}\right\rangle,\ E=34.8\ \mathrm{meV} \tag*{(23)}

Momentary deviations from D2dD_{2d} point symmetry, caused by phonons, allow for transitions between these erstwhile eigenstates. Phonon modes investigated by room temperature Raman spectra [30, 31] and inelastic neutron scattering [29] that break the D2dD_{2d} symmetry have been reported. Introducing the additional Stevens operators ⟨Γ∣Omn∣Γ⟩\langle\Gamma| O_m^n | \Gamma\rangle for m=2,4,6m = 2,4,6 and n=0,2,4,6n = 0,2,4,6 and calculating the associated matrix elements, we find that the extended CEF parameters allow transitions between (+Γ71,−Γ61)(+\Gamma_7^1,-\Gamma_6^1) and (−Γ71,+Γ61)(-\Gamma_7^1,+\Gamma_6^1). There is, however, no allowed transition between/within the ground state doublet: ⟨Γ71∣Omn∣−Γ71⟩=0\langle\Gamma_7^1 | O_m^n | -\Gamma_7^1 \rangle= 0 (this is ultimately a consequence of these being Kramers doublets, with a minimal degeneracy of 2 in the absence of breaking time reversal symmetry). Thus, the spin-lattice relaxation must occur via an indirect process, and hence the transition rate is strongly affected by thermal population of the relevant phonon modes.

AC magnetic susceptibility and AC MCE of GdVO4

GdVO4_4 has the same crystal structure as YbVO4_4. The absence of CEF effects for the Gd ion means that the Hunds rule ground state remains unsplit in zero field. The material undergoes an antiferromagnetic transition at 2.5 K, followed by a spin-flop phase down to 1.37 K [32]. It is paramagnetic at 3 K.

Both YbVO4_4 and GdVO4_4 exhibit a large magnetocaloric effect at low temperatures. The physical origin in both cases is of course the strong variation of the internal entropy as a function of field and temperature, due to Zeeman splitting of the magnetic states. Figure 6 illustrates the calculated entropy landscapes for both compounds, including the phonon background (for clarity and simplicity we neglect the magnetic order in GdVO4_4). Adiabatic changes in magnetic field will yield comparably large changes in temperature for the two materials.

Figure 6. The calculated entropy change of (a) GdVO4_4 and (b) YbVO4_4 with respect to the entropy value of 2 K and 0 T, including the entropy of the lattice and the 4f contribution. The black lines represent isentropic contours.

Whereas YbVO4_4 exhibits slow relaxation dynamics at low temperatures, no such relaxation effects are observed in GdVO4_4 because of the absence of any significant phonon bottleneck effects. In Figure 7, we show the measured χAC(ω)\chi_{\mathrm{AC}}(\omega) and ΓAC(ω)\Gamma_{\mathrm{AC}}(\omega) at 3 K. Notably, no significant frequency dependence was observed, and the amplitude of the out-of-phase component remained comparable to the background noise for frequencies below 100 Hz. Thus GdVO4_4 provides a useful counterpoint in which there are no internal relaxation effects in the frequency range measured, and extrinsic time constants associated with both measurements exceed the maximum accessible frequency of the AC experiments.

Real and imaginary parts of the magnetic and thermal response functions of GdVO4

Figure 7. Real and imaginary parts of the magnetic and thermal response functions χAC(ω)\chi_{\mathrm{AC}}(\omega) (panels a and b) and ΓAC(ω)\Gamma_{\mathrm{AC}}(\omega) (panels c and d) of GdVO4_4 as a function of frequency. Data were all taken at 3K, for DC fields varying from 0 T to 0.18 T. The same sample, with the same mounting configuration, was used for both measurements.

Simplified Thermal Exchange Model

In this section, we further explain the origin of the simplified expression for χAC(ω)\chi_{\mathrm{AC}}(\omega) discussed in Section IV.

We consider a scenario in which the lattice and the heat bath in Figure 1(b) have good thermal contact, hence, the two components are considered as a single environment relative to the 4f spin subsystem. By assuming the magnetocaloric effect heats the sample uniformly in ideal thermal conditions (i.e., neglecting the kind of extrinsic mounting effects described in Appendix E), the heat transfer between the spin subsystem and a constant bath is described by a thermal transfer equation:

\begin{bmatrix} dS(\omega) \\ dM(\omega) \end{bmatrix} = \begin{bmatrix} \frac{C}{T} & \gamma\\ \gamma& \chi\end{bmatrix}^{4f} \begin{bmatrix} dT(\omega) \\ dH(\omega) \end{bmatrix}^{4f} \tag*{(24)}\end{bmatrix}
−iωT4fdS4f(ω)=−κint(dT4f(ω)−dTbat)-i\omega T^{4f}dS^{4f}(\omega)=-\kappa_{\mathrm{int}}\left(dT^{4f}(\omega)-dT^{\mathrm{bat}}\right)

Holding dTbat=0dT^{\mathrm{bat}}=0 and solving for (24), we obtain:

χAC(ω)=dM4f(ω)dH(ω)=χ4f−T0(γ4f)2(−iω)C4f(−iω)+κint(25)\chi_{\mathrm{AC}}(\omega)=\frac{dM^{4f}(\omega)}{dH(\omega)}=\chi^{4f}-\frac{T_0(\gamma^{4f})^2(-i\omega)}{C^{4f}(-i\omega)+\kappa_{\mathrm{int}}} \tag*{(25)}

The solution here is the same as the solution of χAC(ω)\chi_{\mathrm{AC}}(\omega) solved from Eq. 6, which we obtained by assuming that the effective κext\kappa_{\mathrm{ext}} goes to zero and the effective ClC^{l} is much greater than C4fC^{4f} (which leads to Eq. 11). Good extrinsic thermal contact in Eq. 6 implies a large value of κext\kappa_{\mathrm{ext}}, but these two models are actually the same. Intuitively, good thermal contact with the bath (large κext\kappa_{\mathrm{ext}}) is thermally equivalent to a single, infinitely large lattice (large ClC_l)—isolated (small κext\kappa_{\mathrm{ext}}) or otherwise. Mathematically, this can be justified with the fact that Eq. 8 is the same in the limit of Cl→∞C_l\rightarrow\infty and the limit of κext→∞\kappa_{\mathrm{ext}}\rightarrow\infty. Therefore, the approximation/limits affecting ClC_l and κext\kappa_{\mathrm{ext}} in the main text, and the simplified thermal exchange model outlined here, are equivalent in explaining the Debye-like relaxation behavior observed in χAC(ω)\chi_{\mathrm{AC}}(\omega). Such ideas of an extended lattice bath cannot be considered in the AC MCE, because the thermometer measures a local region of the sample.

Effect of the thermal sensor on the measured response

The heat exchange model in the main text overlooks the effect of the thermal sensor. This was justified because ideally the sensor only has a marginal impact on the thermal exchange between the major subsystems/components, and our goal has been to reveal the essential physics necessary to describe the major heat flows in the physical system.

Here, we develop a generalized description of the system that treats the temperature of the sample Ts(ω)T^{s}(\omega) and of the thermometer Tθ(ω)T^{\theta}(\omega) as independent values. We consider the simplest scenario, in which a thermal sensor is attached to a part of a sample with thermal conductivity κθ\kappa_{\theta}. If the sample and sensor have a good thermal contact, the associated (third) time constant τθ=ClCθκθ(Cl+Cθ)≃Cθ/κθ\tau_{\theta}=\frac{C^{l}C^{\theta}}{\kappa_{\theta}(C^{l}+C^{\theta})}\simeq C^{\theta}/\kappa_{\theta} will be much smaller than τint\tau_{\mathrm{int}} and τext\tau_{\mathrm{ext}}, and the heat flow will be essentially instantaneous relative to the important timescales being probed by the experiment. More generally, heat flow between the sample and sensor is governed by the equation:

qθ←sample=−TθdSθ(t)dt=−κθ(dTθ(t)−dTsample(t)).(26)q_{\theta\leftarrow sample}=-T^{\theta}\frac{dS^{\theta}(t)}{dt}=-\kappa_{\theta}\left(dT^{\theta}(t)-dT^{sample}(t)\right). \tag*{(26)}

Following the same principles developed in the main text, we can also write the equation in its frequency components:

−iωdSθ(ω)Tθ=−κθ(dTθ(ω)−dTsample(ω))-i\omega dS^{\theta}(\omega)T^{\theta}=-\kappa_{\theta}\left(dT^{\theta}(\omega)-dT^{sample}(\omega)\right)
dSθ(ω)=CθT0dTθ(ω).(27)dS^{\theta}(\omega)=\frac{C^{\theta}}{T_0}dT^{\theta}(\omega). \tag*{(27)}

(27) can be solved together with (6) to include the heat flow between the lattice and the sensor to extend the thermal model. We can then obtain expressions for the sensor temperature Tθ(ω)T_{\theta}(\omega).

We note that for a well-designed experiment, the response function Γθ(ω)\Gamma_{\theta}(\omega) is very close to that of the material Γlattice(ω)\Gamma_{\mathrm{lattice}}(\omega) (ΓAC(ω)\Gamma_{\mathrm{AC}}(\omega) in the main text). Heat exchange with the thermal sensor also affects the magnetic response, modifying the expression for χAC(ω)\chi_{\mathrm{AC}}(\omega) if those data are taken while the thermal sensor is attached. The modified expressions are given by:

χAC(ω)=χ4f−T0(γ4f)2(iω)((κint+κext)κθ−ClCθω2−iNω)−κintκextκθ+ω2D1+iωD2\chi_{\mathrm{AC}}(\omega)=\chi^{4f}-\frac{T_0(\gamma^{4f})^2(i\omega)\left((\kappa_{\mathrm{int}}+\kappa_{\mathrm{ext}})\kappa_{\theta}-C^{l}C^{\theta}\omega^2-iN\omega\right)}{-\kappa_{\mathrm{int}}\kappa_{\mathrm{ext}}\kappa_{\theta}+\omega^2D_1+i\omega D_2}
Γθ(ω)=−T0γ4fκintκθ(iω)−κintκextκθ+ω2D1+iωD2,\Gamma_{\theta}(\omega)=\frac{-T_0\gamma^{4f}\kappa_{\mathrm{int}}\kappa_{\theta}(i\omega)}{-\kappa_{\mathrm{int}}\kappa_{\mathrm{ext}}\kappa_{\theta}+\omega^2D_1+i\omega D_2},

with

N=Clκθ+Cθ(κint+κext+κθ),N=C^{l}\kappa_{\theta}+C^{\theta}(\kappa_{\mathrm{int}}+\kappa_{\mathrm{ext}}+\kappa_{\theta}),
D1=C4fClκθ+CθClκint+C4fCθ(κint+κext+κθ),D_1=C^{4f}C^{l}\kappa_{\theta}+C^{\theta}C^{l}\kappa_{\mathrm{int}}+C^{4f}C^{\theta}(\kappa_{\mathrm{int}}+\kappa_{\mathrm{ext}}+\kappa_{\theta}),
D2=(C4fκint+Clκint+C4fκext)κθ+Cθκint(κext+κθ)−C4fClCθω2(28)D_2=(C^{4f}\kappa_{\mathrm{int}}+C^{l}\kappa_{\mathrm{int}}+C^{4f}\kappa_{\mathrm{ext}})\kappa_{\theta}+C^{\theta}\kappa_{\mathrm{int}}(\kappa_{\mathrm{ext}}+\kappa_{\theta})-C^{4f}C^{l}C^{\theta}\omega^2 \tag*{(28)}

whereas the lattice temperature is

Γlattice(ω)=−T0γ4fκint(iω)(κθ−iCθω)−κintκextκθ+ω2D1+iωD2(29)\Gamma_{\mathrm{lattice}}(\omega)=\frac{-T_0\gamma^{4f}\kappa_{\mathrm{int}}(i\omega)(\kappa_{\theta}-iC^{\theta}\omega)}{-\kappa_{\mathrm{int}}\kappa_{\mathrm{ext}}\kappa_{\theta}+\omega^2D_1+i\omega D_2} \tag*{(29)}

A comparison of the solutions is illustrated in Figure 8. The green and blue lines in Panel (a) plot the magnetic response dM/dHdM/dH, which does not change significantly if we assume a reasonable choice of thermometer, namely smaller thermal mass and comparable thermal connection compared to the rest of the setup. Meanwhile, the Cole-cole plot of the magnetocaloric response is distorted from the circular behavior in the simpler model. While the thermometer and the lattice temperatures follow the simpler solution of lattice response closely at the low frequency limit, the three curves diverge at higher frequencies as the thermometer progressively decouples from the sample. At high enough frequencies, the phase of Γθ(ω)\Gamma_{\theta}(\omega) goes beyond π/2\pi/2, leading to an opposite change in temperature between the lattice and the thermometer.

Calculated Cole-Cole plots of the thermal model including a thermometer with finite heat capacity and thermal conductivity

Figure 8. Calculated Cole-Cole plots of the thermal model including a thermometer with finite heat capacity (CθC^\theta) and thermal conductivity (κθ\kappa_\theta). Panel (a) compares the magnetic response solved with and without the thermometer, and panel (b) plots the magnetocaloric response seen in the lattice (Γlattice(ω)\Gamma_{\mathrm{lattice}}(\omega)) and in the thermometer (Γθ(ω)\Gamma_\theta(\omega)). Parameters used here are η=Cθ/C4f=0.1\eta=C^\theta/C^{4f}=0.1, Cθ/Cθ=2C^\theta/C^\theta=2, τint/τext=0.5\tau_{\mathrm{int}}/\tau_{\mathrm{ext}}=0.5, τint/τθ=0.1\tau_{\mathrm{int}}/\tau_\theta=0.1.

The heat flow in the real experiment can further differ from the idealized behavior described above. In particular, since the size of the thermal sensor is typically much smaller than the sample, at sufficiently high frequencies it cannot exchange heat evenly with the entirety of the sample. This consideration has a negligible effect when the sensor is vanishingly small and in good thermal contact with the sample. However, when the thermometer has a limited rate of thermal exchange defined by either geometry or contact materials, the mounting geometry can introduce inhomogeneous thermal gradients, and hence the measured thermal response cannot be properly described by the idealized discrete thermal model. In practice, this means that care must be taken that the thermal sensor (including wiring and associated heat flow) does not overly perturb the overall heat flow so much as to obscure the MCE oscillations that are the focus of the measurement.

To experimentally demonstrate the extrinsic effects that the thermal sensor can introduce, we designed two additional experiments in which the thermal sensor is deliberately connected indirectly to the sample of YbVO4_4. The two experiments are illustrated in panels (a) and (b) in Figure 9. In the first of these, the thermal sensor is attached to the back side of the quartz plate to which the sample is affixed. In the second, the thermal sensor is attached to the sample via a thin gold wire (i.e. a heat pipe). The results are displayed as Cole-Cole plots in panels (c) and (d) of Figure 9.

Schematic diagrams and Cole-Cole plots illustrating two additional methods to mount a sample for AC MCE measurements

Figure 9. (a,b) Schematic diagrams illustrating two additional methods to mount a sample for AC MCE measurements, as examples of sub-optimal mounting conditions which limit the thermal conduction rate between the sample (blue bar) and the thermal sensor (RxR_x). In (a) the thermometer and sample are separated by the quartz component that the sample is mounted on, and in (b) they are separated by a 0.05 mm diameter gold wire which serves as a heat pipe. (c) The Cole-Cole plot of β/βmax⁡\beta/\beta_{\max} of the sample mounted following the method shown in (a). Real and imaginary parts of β\beta have been normalized by the maximal value βmax⁡\beta_{\max} for each curve. (d) The Cole-Cole plot of the measurement result for the sample mounted following the method shown in (b). Both measurements were for YbVO4_4 at a temperature of 3 K.

When the sensor and the sample are separated by a single quartz component, the resulting Cole-Cole plot deviates from a circular shape for lower frequencies (Figure 9(c)). In particular, the Cole-Cole plot now reveals a response in three quadrants (including negative values of Γ′\Gamma' in Quadrant II). This is distinct from the case in which the thermal sensor is neglected, and for which the response is always Γ′>0\Gamma' > 0 (i.e. only in Quadrants I and IV). This behavior is described by Eqn. (28), as illustrated in Figure 8, and is indicative of an additional slow thermal time constant associated with relaxation between the sample and the thermal sensor.

In contrast, when the sample and sensor are separated by a thin gold wire, deviations from the circular Cole-Cole plot are evident at higher frequencies (Figure 9(d)). This behavior is again evident of a third time constant, but with a different characteristic frequency.

In summary, the thermal sensor can affect the observed response function. A well-designed experiment has negligible effect, and is evident from a circular Cole-Cole response. The effect of the thermal sensor can be quantitatively accounted for so long as thermal gradients are minimized.

Additional plots of the solutions of the thermal exchange model for a wider range of parameters

The plots in Figure 1(c) and (d) illustrate a specific case: τintτext>1\frac{\tau_{\mathrm{int}}}{\tau_{\mathrm{ext}}}>1 (a necessary requirement for a good measurement of the MCE response). To illustrate wider solutions of the thermal model described by Eq. (8) and 9, we plot here the real and imaginary parts of the two response functions for a wider range of τintτext\frac{\tau_{\mathrm{int}}}{\tau_{\mathrm{ext}}}, obtained by changing κext\kappa_{\mathrm{ext}} and fixing other parameters constant. As τintτext\frac{\tau_{\mathrm{int}}}{\tau_{\mathrm{ext}}} is reduced, a second semicircle feature emerges in the Cole-Cole plot of χAC(ω)\chi_{\mathrm{AC}}(\omega), which is manifested as an extra plateau in χAC′(ω)\chi'_{\mathrm{AC}}(\omega) and an extra peak in χAC′′(ω)\chi''_{\mathrm{AC}}(\omega). In contrast, ΓAC(ω)\Gamma_{\mathrm{AC}}(\omega) remains circular on the associated Cole-Cole plot. As shown in Figure 10 (d) and (e), ΓAC′\Gamma_{\mathrm{AC}}^{\prime} and ΓAC′′\Gamma_{\mathrm{AC}}^{\prime\prime} grow at the same time when τint/τext\tau_{\mathrm{int}}/\tau_{\mathrm{ext}} decreases. Consequently, the radius of ΓAC(ω)\Gamma_{\mathrm{AC}}(\omega) on the Cole-Cole plot (panel (f)) grows proportionally. As described in Appendix E, deviations from this perfect circle are anticipated and observed when heat exchange with the thermal sensor becomes a significant factor.

Solutions of $\chi_{\mathrm{AC}}(\omega)$ and $\Gamma_{\mathrm{AC}}(\omega)$

Figure 10. More solutions of χAC(ω)\chi_{\mathrm{AC}}(\omega) and ΓAC(ω)\Gamma_{\mathrm{AC}}(\omega) based on Eq. 8 and 9. The plot was made by setting T0T_0, γ4f\gamma^{4f}, C4fC^{4f}, ClC^{l} and κint\kappa_{\mathrm{int}} as fixed value and only change the value of κext\kappa_{\mathrm{ext}}, so that the ratio of the two time constants τint=(ClC4f)/(κint(Cl+C4f))\tau_{\mathrm{int}} = (C^{l}C^{4f})/(\kappa_{\mathrm{int}}(C^{l}+C^{4f})) and τext=Cl/κext\tau_{\mathrm{ext}} = C^{l}/\kappa_{\mathrm{ext}} can be compared when they are either close or well-separated from each other. Here we pick Cl=C4fC^{l} = C^{4f} for simplicity. Viewed on a normalized Cole-Cole plot (panel (c)), the magnetic response χAC(ω)\chi_{\mathrm{AC}}(\omega) exhibits two clear semicircles for small values of τintτext\frac{\tau_{\mathrm{int}}}{\tau_{\mathrm{ext}}}, merging into a single semicircle for large values. In contrast, the thermal response ΓAC(ω)\Gamma_{\mathrm{AC}}(\omega) is a circle on a Cole-Cole plot (panel (f)) for all values of τintτext\frac{\tau_{\mathrm{int}}}{\tau_{\mathrm{ext}}}.

Best-fit parameters obtained from fitting to Equations 12 and 13

In Figure 11, we plot the remaining fit parameters corresponding to the dashed lines in Figure 4 as a function of magnetic field.

Best fit parameters as a function of magnetic field

Figure 11. Best fit parameters from fitting experimental data to Eqn. 12 and 13, including the heat capacity ratios η=Cl/Cin4f\eta= C^{l}/C^{4f}_{\mathrm{in}} (a), the magnetocaloric coefficient γ4f=∂S4f/∂H∣T\gamma^{4f} = \left.\partial S^{4f}/\partial H\right|_{T} in (b), and the empirical stretching factor rr in (c). All parameters here are obtained by fitting to AC susceptibility and AC MCE data simultaneously, taken at different magnetic fields at 3 K.

The empirical stretching factor rr has a zero-field value close to 0.8 and exhibits only a very slight field dependence. Its proximity to 1 and small field-dependence imply that the simplified heat exchange model that we use to describe this system, which uses just two time constants, captures the essential physical processes remarkably accurately. See Appendix E for possible factors that contribute to rr deviating from unity.

In contrast, the parameters η=Cl/C4f\eta= C^{l}/C^{4f} and γ4f=∂S4f/∂H∣T\gamma^{4f} = \left.\partial S^{4f}/\partial H\right|_{T} both reveal a large field dependence. This behavior is expected given the field-induced changes in the material properties. In particular, when the magnetic field increases, ClC^{l} stays constant at a fixed temperature, but C4fC^{4f} increases due to the field-induced splitting of the CEF doublet (i.e. a field-induced Schottky anomaly). Hence, η\eta decreases with increasing field. Similarly, as the spins are more aligned at higher field, the induced entropy change decreases, and hence the magnitude of γ4f\gamma^{4f} decreases with increasing field.

Finally, we comment that the spin-lattice relaxation time exhibits an exponential behavior as a function of the magnetic field, as illustrated in Figure 12. This is consistent with the resonance relaxation process when kBΘD>Δqk_{\mathrm{B}}\Theta_{\mathrm{D}} > \Delta_q (as elaborated by Orbach [2]), where Δq\Delta_q is the transition energy that phonons resonate with. If the energy gap between the ground state doublet and the first excited doublet at zero field is Δ0\Delta_0, then as the doublets split due to the Zeeman effect, the energy difference also changes linearly to the magnetic field. Therefore, we expect

Exponential fit of the field dependence of $\tau_{\mathrm{int}}^{-1}$

Figure 12. Exponential fit of the field dependence of τint−1\tau_{\mathrm{int}}^{-1}. Red circles are the fitted spin-lattice relaxation time (same as those in Figure 4). The dashed black line plots the best-fit to b+Ae−k⋅Hb + A e^{-k\cdot H}, with parameters are b=57.2b = 57.2 Hz, A=835.6A = 835.6 Hz, k=4.3k = 4.3 T−1^{-1}.

1/τ∝e−(Δ0+geffμBB)/(kBT)∝e−geffμBB/(kBT)1/\tau\propto e^{-(\Delta_0+g_{\mathrm{eff}}\mu_{\mathrm{B}}B)/(k_{\mathrm{B}}T)} \propto e^{-g_{\mathrm{eff}}\mu_{\mathrm{B}}B/(k_{\mathrm{B}}T)}

at low temperatures. Fitting the results at 3 Kelvin, we extracted geff=k/(μB/(kBT))=19.4g_{\mathrm{eff}} = k/(\mu_{\mathrm{B}/(k_{\mathrm{B}}T)) = 19.4}.

References

References

  1. [1]C. V. Topping and S. J. Blundell, Journal of Physics: Condensed Matter 31, 013001 (2018).
  2. [2]R. Orbach, Proceedings of the Royal Society of London. Series A, Mathematical and Physical Sciences 264, 458 (1961).
  3. [3]J. A. Quilliam, S. Meng, C. G. A. Mugford, and J. B. Kycia, Phys. Rev. Lett. 101, 187204 (2008).
  4. [4]J. A. Quilliam, L. R. Yaraskavitch, H. A. Dabkowska, B. D. Gaulin, and J. B. Kycia, Phys. Rev. B 83, 094424 (2011).
  5. [5]S. Gómez-Coca, A. Urtizberea, E. Cremades, P. J. Alonso, A. Camón, E. Ruiz, and F. Luis, Nature Communications 5, 4300 (2014).
  6. [6]A. Khansili, A. Bangura, R. D. McDonald, B. J. Ramshaw, A. Rydh, and A. Shekhter, Phys. Rev. B 107, 195145 (2023).
  7. [7]G. J. Bowden, Australian Journal of Physics 51, 201 (1998).
  8. [8]P. Radhakrishna, J. Hammann, and P. Pari, Journal of Magnetism and Magnetic Materials 23, 254 (1981).
  9. [9]L. D. Abraham, The Principles of Nuclear Magnetism (Oxford University Press, Oxford, 1961).
  10. [10]E. Warburg, Annalen der Physik 249, 141 (1881).
  11. [11]Y. Kohama, C. Marcenat, T. Klein, and M. Jaime, Review of Scientific Instruments 81, 104902 (2010).
  12. [12]E. Brück, Journal of Physics D: Applied Physics 38, R381 (2005).
  13. [13]J. Y. Law, V. Franco, L. M. Moreno-Ramírez, A. Conde, D. Y. Karpenkov, I. Radulov, K. P. Skokov, and O. Gutfleisch, Nature Communications 9, 2680 (2018).
  14. [14]C. Pereira, R. Almeida, R. Kiefe, C. Amorim, D. Silva, J. Amaral, and J. Belo, Journal of Alloys and Compounds 976, 173290 (2024).
  15. [15]Z. A. Kazei and R. I. Chanieva, Journal of Experimental and Theoretical Physics 102, 266 (2006).
  16. [16]E. Palacios, M. Evangelisti, R. Sáez-Puche, A. J. Dos Santos-García, F. Fernández-Martínez, C. Cascales, M. Castro, R. Burriel, O. Fabelo, and J. A. Rodríguez-Velamazán, Phys. Rev. B 97, 214401 (2018).
  17. [17]B. Fischer, J. Hoffmann, H. Kahle, and W. Paul, Journal of Magnetism and Magnetic Materials 94, 79 (1991).
  18. [18]Y. Tokiwa and P. Gegenwart, Review of Scientific Instruments 82, 013905 (2011).
  19. [19]A. Aliev, A. Batdalov, L. Khanov, V. Koledov, V. Shavrov, I. Tereshina, and S. Taskaev, Journal of Alloys and Compounds 676, 601 (2016).
  20. [20]Journal of Magnetism and Magnetic Materials 553, 169300 (2022).
  21. [21]P. Massat, J. Wen, J. M. Jiang, A. T. Hristov, Y. Liu, R. W. Smaha, R. S. Feigelson, Y. S. Lee, R. M. Fernandes, and I. R. Fisher, Proceedings of the National Academy of Sciences 119, e2119942119 (2022).
  22. [22]A. Vallipuram, L. Chen, E. Campillo, M. Mezidi, G. Grisone, M.-E. Boulanger, F. LeFrançois, M. P. Zic, Y. Li, I. R. Fisher, J. Baglo, and L. Taillefer, Phys. Rev. B 110, 045144 (2024).
  23. [23]R. Feigelson, Journal of the American Ceramic Society 51, 538 (1968).
  24. [24]S. Smith and B. Wanklyn, Journal of Crystal Growth 21, 23 (1974).
  25. [25]K. Oka, H. Unoki, H. Shibata, and H. Eisaiki, Journal of Crystal growth 286, 288 (2006).
  26. [26]A. Landau and E. M. Lifshitz, Statistical Physics, Volume 5, Chapter 110 (Butterworth-Heinemann, 1980).
  27. [27]L. Onsager, Phys. Rev. 37, 405 (1931).
  28. [28]SR860 Lock-In Amplifier User Manual, Stanford Research Systems (2023), revision 2.1.
  29. [29]J. Nipko, C.-K. Loong, S. Kern, M. Abraham, and L. Boatner, Journal of Alloys and Compounds 250, 569 (1997).
  30. [30]C. C. Santos, E. N. Silva, A. P. Ayala, I. Guedes, P. S. Pizani, C.-K. Loong, and L. A. Boatner, Journal of Applied Physics 101, 053511 (2007).
  31. [31]C. Santos, I. Guedes, C.-K. Loong, and L. Boatner, Vibrational Spectroscopy 45, 95 (2007), raman Spec- troscopy Workshop 2006.
  32. [32]B. W. Mangum and D. D. Thornton, AIP Conference Proceedings 5, 311 (1972).

Paper details

vlnc:W_fndz4znc
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents