The Role of Electrolytes in the Relaxation of Near-Surface Spin Defects in Diamond

Abstract

Quantum sensing with spin defects in diamond, such as the nitrogen-vacancy (NV) center, enables the detection of various chemical species on the nanoscale. Molecules or ions with unpaired electronic spins are typically probed by their influence on the NV center's spin relaxation. Whereas it is well-known that paramagnetic ions reduce the NV center's relaxation time (T1T_1), here we report on the opposite effect for diamagnetic ions. We demonstrate that millimolar concentrations of aqueous diamagnetic electrolyte solutions increase the T1T_1 time of near-surface NV center ensembles compared to pure water. To elucidate the underlying mechanism of this surprising effect, single and double quantum NV experiments are performed, which indicate a reduction of magnetic and electric noise in the presence of diamagnetic electrolytes. In combination with ab initio simulations, we propose that a change in the interfacial band bending due to the formation of an electric double layer leads to a stabilization of fluctuating charges at the interface of an oxidized diamond. This work not only helps to understand noise sources in quantum systems but could also broaden the application space of quantum sensors towards electrolyte sensing in cell biology, neuroscience and electrochemistry.

Nitrogen-vacancy (NV) centers in diamond offer a broad platform for quantum sensing applications ranging from the measurement of basic physical properties, such as temperature, [1] pressure, [2] strain, [3] electric[4] and magnetic fields[5, 6] down to single cells, [7] single molecules, [8] or even single nuclear spins. [9, 10] This high sensitivity is achieved due to the atomic size of the qubit enabling its location only a few nanometer away from the diamond interface (see Figure 1a). [11] Near-surface NV centers (≤20\le20 nm below the surface) can be used to sense nuclear magnetic resonance (NMR) [8, 12, 13, 14, 15] and electron spin resonance (ESR) signals [16] from nanoscale chemical and biological samples. The NV center translates these magnetic field fluctuations directly to an optical signal, detected by a change in the fluorescence intensity. Together with optical spin state initialization with green laser light and coherent spin state manipulation with microwave pulses, these key features make the NV center a suitable tool for (bio)chemical analysis. [11, 15, 17, 18]

Scheme of NV relaxometry experiments with aqueous electrolyte solutions

Figure 1. Scheme of NV relaxometry experiments with aqueous electrolyte solutions. (a) Top (left): The NV center in the diamond crystal lattice. A nitrogen atom (blue) replaces a carbon atom (black) in the crystal. Together with an adjacent vacancy an NV center is formed. The orbitals (petrol) indicate four possible NV center orientations within the diamond lattice. Top (right): Scheme of an oxidized diamond surface with an ensemble of near-surface NV centers (dNV∼5d_{\mathrm{NV}} \sim5 nm). The surface termination consists of hydroxyl groups, ethers, ketones, aldehydes and carboxylic acids. We probe pure water, paramagnetic (purple) and diamagnetic (yellow) ions. Bottom: A microfluidic device placed on top of the diamond. In- and outlet allow for adding and removing aqueous electrolyte solutions or pure water from the diamond surface. (b) Top (left): NV relaxometry pulse sequence. Two laser pulses for spin state initialization and readout are separated by a sweep time tt. A consecutive measurement with a π\pi-pulse at the end is used for noise cancellation.[18] Top (right): Energy levels of the NV center’s electronic ground state (S=1S = 1). The zero-field splitting (D=2.87D = 2.87 GHz) separates the ms=0m_s = 0 (bright) and ms=±1m_s = \pm1 states (dark). A bias magnetic field B0B_0 splits the degenerate ms=±1m_s = \pm1 states according to the Zeeman effect. Bottom: T1T_1 relaxation curves of pure water and solutions of NaCl (500 mM) and MnCl2_2 (1 µM). While paramagnetic MnCl2_2 reduces the T1T_1 time with respect to pure water, diamagnetic NaCl extends the T1T_1 time. Experiments are performed at fNV=1.88f_{\mathrm{NV}} = 1.88 GHz.

NV centers are also perceptive to electric fields. [4, 19] Even a single elementary charge located ∼150\sim150 nm away from the quantum sensor produces a strong enough static electric field to affect an NV center’s ODMR (optically detected magnetic resonance) transitions. [4]

This high sensitivity of NV centers to magnetic or electric fields marks a narrow ridge: On the one hand, it allows for single nuclear spin or elementary charge detection, on the other hand it makes the qubit prone to magnetic or electronic spin noise in its close environment. This is particularly relevant for NV centers close to the surface, where interfacial processes and defects cause additional noise and reduce the performance of the NV-quantum sensors. [20, 21, 22, 23]

Due to the NV center’s susceptibility to a broad range of frequencies (from DC to GHz), [24] noise can be measured by applying different sensing protocols. [18] High frequency noise (∼\sim GHz) can be probed by the longitudinal spin-lattice relaxation time (T1T_1) with a protocol that is usually referred to as NV relaxometry. [17, 18, 24, 25, 26] The T1T_1 time defines the time constant of the spin-state-dependent fluorescence decay from the magnetic sublevel ms=0m_s = 0 (bright state) to thermal equilibrium (mixed state) and is on the order of a few milliseconds for near-surface NV-ensembles in bulk diamonds, [11] or on the order of a few hundred microseconds for nanodiamonds (depending on their size). [17] Generally, any magnetic noise overlapping with the NV center’s Larmor frequency (on the order of the zero-field splitting D=2.87D = 2.87 GHz) will decrease the T1T_1 relaxation time (see Figure 1b). [18, 25, 27, 28] Relaxometry has been successfully applied to map high frequency magnetic noise originating from inside the diamond (e.g., paramagnetic impurities [29]), at the diamond interface (e.g., dangling bonds [20, 30]) or from samples on top of the diamond (e.g., organic radicals [27, 31] or paramagnetic ions, such as Mn2+^{2+}, [32] Fe3+^{3+}, [33] or Gd3+^{3+} [25, 28]). Furthermore, nanoscale NV relaxometry has also been used to determine the pH value [34] or to monitor chemical reactions in situ. [35]

While the increase of the relaxation rate due to paramagnetic species has been studied extensively, herein we detect the opposite effect for diamagnetic ions. When near-surface NV centers in oxidized diamonds are exposed to aqueous diamagnetic electrolytes, we observe a systematic extension of the T1T_1 relaxation time compared to pure (deionized) water. We show that this unexpected effect is proportional to the electrolyte concentration, reversible and dependent on the NV center’s implantation depth. In order to shed light on the underlying sensing mechanism, we perform single and double quantum relaxometry experiments which indicate a reduction of electric as well as magnetic noise. Furthermore, double electron electron resonance (DEER) experiments show a similar effect on surface dark spins, which possibly act as surface reporter spins. In combination with theoretical methods including ab initio simulations of the diamond/electrolyte interface, we propose that diamagnetic ions alter the interfacial band bending. This leads to a stabilization of fluctuating charges at the interface and to the increase of the T1T_1 relaxation time.

Results

T1T_1 Relaxometry on Electrolytes with Near-Surface NV center Ensembles

In this study we use near-surface high density NV center ensembles (implanted with 15N{}^{15}\mathrm{N} at an energy of 2.5 keV and a fluence of 2×1012 cm−22 \times10^{12}\,\mathrm{cm}^{-2}), distributed ∼5\sim5 nm underneath the diamond surface,[13, 36, 37] to investigate the effect of aqueous electrolyte solutions on the spin-lattice relaxation time T1T_1 probed by NV relaxometry. Before experiments are conducted, we prepare the diamond surface with a triacid clean procedure according to Brown Brown et al.38. This procedure not only ensures to remove non-diamond carbon material from the interface but also creates an oxidized surface comprised of hydroxyl groups, ethers, ketones, aldehydes and carboxylic acids.[39] We position the diamond in a microfluidic device that guarantees controllable in- and output of the applied liquids, prevents sample evaporation and provides a constant and defined volume for following measurements (see Figure 1a).[15] Importantly, the microfluidic device avoids a direct contact between the liquid and the microwave delivery. The NV relaxometry protocol depicted in Figure 1b essentially consists of two 532 nm laser pulses of 5 μ\mus duration for optical spin state initialization and readout separated by a sweep time tt. A subsequent measurement with a π0,−1\pi_{0,-1}-pulse (where the subscripts 0 and -1 indicate transitions between ms=0↔ms=−1m_s = 0 \leftrightarrow m_s = -1) at the end is used for normalization and noise cancellation.[18] The T1T_1 time can be extracted from the (bi)exponential fit of the relaxation

curves depicting the contrast as a function of sweep time tt (see Supplementary Note 1 for fitting details).

We perform the measurements by filling the microfluidic channel and covering the diamond surface either with pure water or aqueous electrolyte solutions (see Methods for detail).

Figure 1b depicts the T1T_1 relaxation curves when water and solutions of diamagnetic NaCl or paramagnetic MnCl2_2 cover the diamond surface. Paramagnetic MnCl2_2 (1 µM) on the diamond leads to a T1T_1 time reduction by a factor of 0.47 ± 0.19 with respect to water, which is in accordance with other studies and can be ascribed to the strong dipole-dipole interaction of the NV center with paramagnetic species.[25, 32] In contrast, when we repeat the same experiment with diamagnetic NaCl (500 mM) solution, we observe an extension of the T1T_1 time by a factor of 2.04 ± 0.45 compared to water. Experiments supporting this observation are also conducted with other diamagnetic salt solutions (mono-, di- and trivalent) and reveal similar results (see Supplementary Note 2). Therefore, we choose NaCl as a representative of a standard diamagnetic electrolyte for the following measurements in our work and expect comparable results for other diamagnetic salt solutions.

Moreover, by tuning the magnetic field B0B_0 and thereby the NV center’s Larmor frequency NV0,−1\mathrm{NV}_{0,-1} (i.e., the ms=0→ms=−1m_s = 0 \to m_s = -1 transition frequency) we are able to map the spectral noise density. We probe water/NaCl (500 mM) solution with NV0,−1\mathrm{NV}_{0,-1} frequencies from 131 MHz to 2.87 GHz and observe a similar effect over the entire frequency range (see Supplementary Note 2). Consequently, the extension of the T1T_1 time of near-surface NV-ensembles with exposure to diamagnetic electrolyte solutions is an effect that covers a broad range of (high) frequencies (i.e., from ∼\sim hundreds of MHz to GHz).

Additionally, in order to exclude an impact of the solvent’s physical properties (i.e., polarity) on our experiments,[19] we choose typical organic solvents whose dielectric constants (κ\kappa) and chemical structure differ significantly from water (κ=8040\kappa= 80^{40}) and probe them with relaxometry (see Supplementary Note 3). Since the T1T_1 time remains unaffected, we conclude that the herein described effect is not induced by the physical properties of water, but by the diamagnetic electrolyte.

Sensitivity of T1T_1 Relaxometry on Electrolytes

In order to obtain information about the sensitivity of the NV relaxometry protocol to para- and diamagnetic electrolyte solutions, we perform additional measurement series where the electrolyte concentration is increased stepwise (from 10−510^{-5} to 10−210^{-2} mM in the case of paramagnetic MnCl2\mathrm{MnCl}_2 and from 10−410^{-4} to 10310^3 mM in the case of diamagnetic NaCl\mathrm{NaCl}).

Paramagnetic MnCl2\mathrm{MnCl}_2 shows a stepwise T1T_1 decrease in micromolar concentrations reaching a decline of up to 86±10%86 \pm10\% for a 10 μM10\ \mu\mathrm{M} solution with respect to water covering the diamond (see Figure 2a and Supplementary Note 4). Note that a further concentration increase (>10 μM> 10\ \mu\mathrm{M}) is not measurable, as it leads to a collapse of the T1T_1 time. In contrast, diamagnetic NaCl\mathrm{NaCl} shows a slight T1T_1 increase compared to water, which then fluctuates moderately from micromolar to lower millimolar concentrations. Importantly, a significant and gradual T1T_1 increase is measurable from 10 mM10\ \mathrm{mM} to 500 mM500\ \mathrm{mM} NaCl\mathrm{NaCl} solution, where the effect saturates at 81±11%81 \pm11\% with respect to water (see Figure 2b and Supplementary Note 4).

NV relaxometry with increasing concentrations of para- and diamagnetic electrolyte solutions

Figure 2. NV relaxometry with increasing concentrations of para- and diamagnetic electrolyte solutions. (a) Paramagnetic MnCl2\mathrm{MnCl_2} shows a stepwise T1T_1 time decrease for concentrations in the micromolar regime until the effect reaches a maximum measurable decline of 86±10%86 \pm10\% for 10 μM10\,\mu\mathrm{M} solutions with respect to water. (b) In contrast, diamagnetic NaCl\mathrm{NaCl} (right) shows a slight increase of the T1T_1 time compared to water, which then fluctuates moderately from the micromolar to the lower millimolar regime. For concentrations ≥10 mM\ge10\,\mathrm{mM} the T1T_1 time increases gradually along with the NaCl\mathrm{NaCl} concentration until the effect saturates to 81±11%81 \pm11\% for NaCl\mathrm{NaCl} (500 mM500\,\mathrm{mM}) solutions. Experiments are performed at fNV=1.88 GHzf_{\mathrm{NV}} = 1.88\,\mathrm{GHz}.

The decrease of the T1T_1 time with paramagnetic species (e.g., MnCl2\mathrm{MnCl}_2) is expected and well studied.[17, 25, 26, 30] Here, high frequency (∼\sim GHz) noise originates from magnetic dipole-dipole interactions of the NV center’s electronic spin and the sample’s electronic spin (“spin-flips”), resulting in a decline of the T1T_1 time if unpaired electrons are near the sensor. However, for diamagnetic ions (e.g., NaCl\mathrm{NaCl}) these interactions are absent as only paired electrons without a (net) magnetic moment are present. Surprisingly, here we observe a gradual extension of the T1T_1 time with increasing millimolar concentrations of diamagnetic NaCl\mathrm{NaCl} solution. To test whether this effect is influenced by the valency of the electrolyte, we perform additional relaxometry experiments which indicate a larger impact on the T1T_1 time by (divalent) MgSO4\mathrm{MgSO}_4 compared to (monovalent) NaCl\mathrm{NaCl} solutions (see Supplementary Note 4).

Reversibility, Passivation and NV center Depth

Because of the surprising observation, that the T1T_1 time increases with diamagnetic electrolyte solutions compared to water covering the diamond, the next experiments concentrate on the mechanism behind this effect. Therefore, we probe the reversibility and passivation of the effect along with the sensor’s response in dependence of its implantation depth. First, we evaluate if the extension of the T1T_1 relaxation time is a reversible process by exposing an oxidized diamond alternatingly to water and NaCl\mathrm{NaCl} (500 mM500\,\mathrm{mM}) solution. Thereby, we show that the T1T_1 relaxation time is altered from “short” in case of water exposure to “long” when NaCl\mathrm{NaCl} solution covers the surface (see Figure 3a in green). Alternating between water and NaCl\mathrm{NaCl} solution demonstrates a 1.83±0.351.83 \pm0.35 fold increase of the T1T_1 time with electrolyte exposure on the oxidized diamond. Note that preparing the diamond surface with an alternative oxidizing reaction (Fenton reaction)[41] leads to similar results to those with the triacid clean procedure (see Supplementary Note 5). In a next step, we examine if the effect is specific to the oxidized diamond surface. Therefore, the formerly oxidized diamond is coated with an aluminium oxide (Al2O3\mathrm{Al_2O_3}) thin film (thickness ∼1\sim1 nm)[13] prepared by Atomic Layer Deposition (ALD). The aluminium oxide thin film ensures a controllable and uniform surface termination with hydroxyl groups. We repeat the previous experiment, but this time the T1T_1 relaxation time remains unaffected by the NaCl solution (see Figure 3a in black).

NV relaxometry experiments with different surface terminations and NV center ensemble implantation depths

Figure 3. NV relaxometry experiments with different surface terminations and NV center ensemble implantation depths. (a) An oxidized diamond is alternatingly covered with water and NaCl (500 mM) solution. The T1T_1 time increases with electrolyte exposure by a factor of 1.83±0.351.83 \pm0.35 with respect to water. Importantly, this behavior can be altered by either the presence or absence of water or NaCl solution. After coating the same diamond with an aluminium oxide (Al2O3\mathrm{Al}_2\mathrm{O}_3) thin film (thickness ∼1\sim1 nm) the T1T_1 time is unaffected by NaCl solution. (b) T1T_1 relaxation curves of water and NaCl (500 mM) solution covering the diamond surface. Diamonds were implanted with 15N{}^{15}\mathrm{N} at an energy of 2.5 keV (top) and 4 keV (bottom) resulting in different NV center ensemble depths (dNVd_{\mathrm{NV}}). While on the shallower implanted diamond the T1T_1 time increases by a factor of around two with exposure to NaCl solution, on the deeper implanted diamond the effect is strongly reduced. Experiments are performed at fNV=1.88f_{\mathrm{NV}} = 1.88 GHz.

Additionally, we investigate if the extent of the electrolyte’s effect is dependent on the depth of the embedded NV center ensemble. Therefore, we prepare two diamonds with 15N{}^{15}\mathrm{N} implantation energies of 2.5 and 4 keV with the triacid clean procedure described before and probe them with NV relaxometry. Near-surface NV centers implanted with an energy of 2.5 keV are mainly distributed within a depth of ∼5\sim5 nm below the surface, while ensembles created with 4 keV 15N{}^{15}\mathrm{N} are located ∼12\sim12 nm beneath the surface.[37] Figure 3b shows a significantly larger effect of the electrolyte on the relaxation time of the shallow implanted NV-diamond with respect to the deeper one, although a T1T_1 time extension is still detectable in the latter case (see also Supplementary Note 6). Importantly, while the effect with the ∼1\sim1 nm thick aluminium oxide layer is completely passivated, a T1T_1 time increase can still be observed on the oxidized diamond when the sensor is ∼5\sim5 to 10 nm further away from the electrolyte. Note that the same measurements conducted with LiCl (500 mM) solution lead to similar results (see Supplementary Note 6).

From these experiments we conclude that the extension of the T1T_1 relaxation time is a reversible and interfacial process which is dependent on the distance of the sensor to the sample.

Additionally, NV charge state alterations or changes in NV-dephasing and NV-coherence are not observed in our experiments (see Supplementary Note 7).

Probing Magnetic and Electric Noise Contributions

In the next set of experiments we investigate if the T1T_1 relaxation time increase originates from a reduction of electric and/or magnetic field noise. Since we are dealing with electrolytes dissolved in water, it is particularly interesting to explore the influence that charged ions and their randomly fluctuating electric fields might have on the T1T_1 relaxation time of the near-surface NV-ensembles. Whereas the typical relaxometry experiments use single quantum (SQ) transitions to probe magnetic field noise (as in the experiments from the previous sections), double quantum (DQ) transitions are influenced by electric field noise. [42] For these transitions, the full NV center ground state (S=1S = 1) is considered, where an additional relaxation pathway between ms=−1↔ms=+1m_s = -1 \leftrightarrow m_s = +1 with Δms=2\Delta m_s = 2 (see Figure 4a) becomes accessible: the DQ transition. Regarding the NV center as a “qutrit” rather than a qubit allows to probe the effect of the diamagnetic electrolyte solution on both electric and magnetic field noise at the same time.

Single quantum (SQ) and double quantum (DQ) relaxation experiments

Figure 4. Single quantum (SQ) and double quantum (DQ) relaxation experiments. (a) Energy level scheme of the NV center ground state transitions. SQ transitions (Δms=±1\Delta m_s = \pm1) with relaxation rates Ω\Omega are susceptible to magnetic noise. The DQ relaxation (Δms=±2\Delta m_s = \pm2) with relaxation rate γ\gamma is magnetically forbidden but susceptible to electric noise. [42] (b) Top: DQ pulse sequence. Bottom: SQ and DQ relaxation curves of water and NaCl (500 mM) solution covering the diamond. Experiments are performed at B0=15B_0 = 15 G, where the NV0,−1_{0,-1} transition is at fNV=2.83f_{\mathrm{NV}} = 2.83 GHz (corresponding to a DQ transition frequency of 80 MHz). T1,SQT_{1,\mathrm{SQ}} increases by a factor of 1.52±0.161.52 \pm0.16 and T1,DQT_{1,\mathrm{DQ}} by a factor of 2.84±0.312.84 \pm0.31 compared to water when the diamond is exposed to NaCl solution.

SQ and DQ relaxometry measurements on the system water/NaCl (500 mM) solution reveal that the diamagnetic electrolyte has an effect on both relaxation channels, i.e., it reduces magnetic as well as electric field fluctuations (see Figure 4b). Here, two different T1T_1 times can be defined: T1,SQT_{1,\mathrm{SQ}} for the relaxation time in the SQ and T1,DQT_{1,\mathrm{DQ}} in the DQ channel. An increase of T1,SQT_{1,\mathrm{SQ}} by a factor of 1.52±0.161.52 \pm0.16 and an increase of T1,DQT_{1,\mathrm{DQ}} by a factor of 2.84±0.312.84 \pm0.31 can be measured in presence of NaCl solution with respect to water (see also Supplementary Note 8). Thus, diamagnetic electrolytes reduce both – electric and magnetic – noise at the diamond surface. Importantly, when we repeat the same experiments with paramagnetic MnCl2_2, only T1,SQT_{1,\mathrm{SQ}} reduces by 80%, whereas the DQ transition remains unaffected compared to water (see Supplementary Note 8). This indicates an exclusive impact of the paramagnetic electrolyte on magnetic field noise and could provide a possible pathway to distinguish para-from diamagnetic ions in solution.

Additionally, we can exclude an influence of diamagnetic NaCl solution on the static electric field environment by performing zero field ESR Measurements (see Supplementary Note 8).

Influence of Electrolytes on Surface Dark Spins: DEER Experiments

So far, we have focused on the direct influence of electrolytes on the NV centers. However, the diamond as the NV center’s host material provides various surface dark spins, e.g., dangling bonds, whose response to the electrolytes is probed in the next set of experiments. Intrinsic T1T_1 times of these surface dark spins are often long (∼\sim a few microseconds) [43] which allows us to probe them with NV-based DEER spectroscopy. [16, 44] Figure 5a shows the pulse sequence of a typical DEER experiment: A spin-echo is performed on the NV center’s electronic spin (MWNV\mathrm{MW}_{\mathrm{NV}} spin-echo), at the same time, in the second free precession time of the echo, an additional microwave pulse (MWDEER\mathrm{MW}_{\mathrm{DEER}}) is applied to drive the target electronic spins. Sweeping the MW frequency (fDEERf_{\mathrm{DEER}}) flips the surface dark spins when their Larmor frequency is matched and causes a dip in the DEER signal (see Figure 5b). As shown in Figure 5b, a clear dip in the DEER spectrum appears when the diamond interface is covered with NaCl (500 mM) solution. The resonance at fDEER=0.887f_{\mathrm{DEER}} = 0.887 GHz corresponds to ge∼2g_e \sim2 spins and is typically assigned to dangling bonds at the diamond surface.[47] Interestingly, the dip is drastically reduced when the experiment is repeated with water.

NV-DEER experiments probing the response of surface dark spins to electrolyte exposure

Figure 5. NV-DEER (double electron electron resonance) experiments probing the response of surface dark spins to electrolyte exposure. (a) Pulse sequence of the DEER experiment. Sweeping the microwave frequency of the MWDEER\mathrm{MW}_{\mathrm{DEER}} pulse (fDEERf_{\mathrm{DEER}}) while applying a spin-echo experiment on the NV center (MWNV spin-echo\mathrm{MW}_{\mathrm{NV\ spin\text{-}echo}}) allows for the detection of electronic (surface dark) spins coupled to the NV centers.[45] (b) DEER experiment with water and NaCl (500 mM) solution covering the diamond surface. A pronounced dip in the DEER spectrum appears at around 0.887 GHz (where ge∼2g_{\mathrm{e}} \sim2) when the diamond is exposed to NaCl solution. The dip gets drastically reduced when water covers the diamond surface. (c) Top: Pulse sequence of the DEER-Rabi experiment. Bottom: When the pulse duration of the microwave drive (MWDEER\mathrm{MW}_{\mathrm{DEER}}) at the surface dark spins’ resonance frequency is swept during the spin-echo, DEER-Rabi oscillations can be observed.[46] While the πds\pi_{\mathrm{ds}}-pulse lengths remain equal when water or NaCl (500 mM) solution cover the diamond surface (πds∼24\pi_{\mathrm{ds}} \sim24 ns), the latter causes a ∼\sim three times more pronounced Rabi amplitude. (d) Top: Pulse sequence of the DEER-T1T_1 experiment. Bottom: Varying the correlation time (tcorrt_{\mathrm{corr}}) between two subsequent DEER segments,[43] shows a surface dark spin relaxation with T1,ds=7.20±1.10T_{1,\mathrm{ds}} = 7.20 \pm1.10 µs in case of NaCl exposure. In contrast, no significant relaxation decay can be observed when water covers the diamond surface. DEER experiments are performed at fNV=1.98f_{\mathrm{NV}} = 1.98 GHz.

Once the resonance condition for the ge∼2g_e \sim2 spins is found, coherent control of the surface dark spin state can be demonstrated. Figure 5c shows a DEER-Rabi experiment on the surface dark spins. Sweeping the microwave pulse duration (MWDEER\mathrm{MW}_{\mathrm{DEER}}) during the spin-echo causes oscillations of the defect’s spin state.[46] While we determine equal πds\pi_{\mathrm{ds}} pulse lengths (πds∼24\pi_{\mathrm{ds}} \sim24 ns) for water and the electrolyte, the former leads to a ∼\sim three-fold increased DEER-Rabi amplitude with respect to the latter. In the next step, we probe the surface dark spin relaxation time (T1,dsT_{1,\mathrm{ds}}). Figure 5d depicts a pulse sequence from Sushkov et al.,[43] where the T1T_1 time of the surface dark spins can be measured by correlating two subsequent DEER segments and varying the correlation time tcorrt_{\mathrm{corr}}. Interestingly, we measure a relaxation time T1,dsT_{1,\mathrm{ds}} of 7.20 ±\pm 1.10 μ\mus for the surface dark spins exposed to the NaCl solution. In contrast, a clear relaxation decay cannot be observed in case of pure water covering the diamond. Although we cannot exclude that the surface dark spins vanish, the more likely case is that the dark spins act as reporter spins[43] experiencing the same effect of the electrolyte solution as the NV center: “fast” relaxation in the case of water and “slow” relaxation when diamagnetic electrolyte solutions cover the diamond, which is also expressed in the increased DEER signals (see Figure 5b-Figure 5d). Accordingly, we enhance the sensitivity of our sensor by the proximity of the reporter spins to the electrolyte solutions.[43, 48]

Theoretical Modeling

Our experimental results show an influence of diamagnetic electrolyte solutions on near-surface spin defects in diamond where electric as well as magnetic noise is suppressed resulting in an increase of the T1T_1 relaxation time. To further study this surprising effect computational modeling is used. Here, as a working assumption, we focus on charge fluctuations within the diamond lattice. We note, that further processes such as proton hopping at the interface or water and ion dynamics within the electric double layer can also play a role but have not been treated herein.

To this end, we model an interface between a slab of diamond and a thin layer of water subsequently enriched by Na+\mathrm{Na}^{+} and Cl−\mathrm{Cl}^{-} ions (see Methods for detail). Then, we probe the interfacial structure and vacuum level shifts (VLS) based on the configurations obtained from the ab initio molecular dynamics (MD) (see Figure 6a). The calculated alignment of the electronic levels of water and the model diamond surface is shown in Figure S12. Here, a mismatch of the chemical potentials (defined as a center of the band gap) promotes an electron leakage from the diamond surface towards the water. The resulting redistribution of charges leads to the development of an electric field, that further rearranges the charged solvated Na+\mathrm{Na}^{+} and Cl−\mathrm{Cl}^{-} ions. The large positive VLS of 1.1 eV (see Figure S12) causes the ions to rearrange with the direction of the field, facilitating the effect of band bending. By adding a carboxyl group, we observe a stabilization of the downwards band bending relative to the case of the model diamond surface in water. However, in both cases, we obtain a broad distribution of surface dipoles, owing to the complexity of ion dynamics within the Stern layer. By contrast, a sharp distribution of the dipole moments is observed between a dissociated carboxyl group and a solvated Na+\mathrm{Na}^{+} ion nearby. This stable configuration gives rise to a large VLS of ∼−1.9\sim-1.9 eV. This value is further used to trace the evolution of the electrostatic potential at the microscopic level. More specifically, we set it as a boundary condition for solving the Poisson equation to access the modifications of the potential inside a semi-infinite diamond slab. As shown in Figure 6b, we observe that the interfacial region of ∼40\sim40 nm is affected by the respective readjustments of the charges, resulting in a rapid decay of the potential near the interface and a slow saturation towards the bulk.

Ab initio MD simulations of the diamond/electrolyte interface

Figure 6. Ab initio MD simulations of the diamond/electrolyte interface. (a) Representative snapshot of the diamond/electrolyte interface from the ab initio MD simulations. Color code: C (grey), O (red), H (white), Na+^{+} (yellow), Cl−^{-} (green). (b) Variations of the electrostatic potential in a semi-infinite diamond due to the arrangement of NaCl at the interface. Inset: Electrostatic potential (ΔVmax⁡\Delta V_{\max}) for a pair of defects in 3 nm distance to each other surrounding a ∼5\sim5 nm deep NV center. (c) Schematic representation of a continuous charge hopping between two defects around the NV center. HABH_{AB} is the transfer integral, ΔG0\Delta G^{0} is calculated as ΔVmax⁡/2\Delta V_{\max}/2 from (b). (d) Calculated rate constants for pairs of substitutional nitrogen and vacancy defects as a function of distance between the defects. (e) Rate constants for the forward and backward electron transfer between a pair of vacancy defects as a function of bias due to the interfacial band bending. Vertical lines refer to an estimated difference in the effects by replacing the electrolyte with pure water, considering a pair of defects and an NV center in a configuration from the inset in (b).

Band alignment, interfacial dipole distributions, average electrostatic potentials and vacuum level shifts, and structures of the model diamond surface

Figure S12. a) Band alignment of the water layer and the model diamond surface. b) Distribution of interfacial dipoles, sampled from the MD trajectories for three different compositions of the interface and solvent. c) Average electrostatic potentials and vacuum level shifts (VLS) computed for the configurations corresponding to the middle of the distributions in b. Vertical lines show the parts of the simulation box, spanned by diamond (C), water or aqueous NaCl solution and vacuum. d) Structures of the model diamond surface before and after adding a COOH group.

To establish a relation between the band bending and the noise reduction, we consider the electric and magnetic fluctuations caused by a pair of active defects around the NV centers. The charge transfer process leads to a continuous change in the charge/spin state of the nearby defects, which can affect the relaxation and coherence time of the NV center when the rate approaches the timescale of the quantum sensing experiment. In the Marcus theory, such fluctuations are described as a sequence of thermally activated hopping events, whilst the rate constants are determined from the distance-dependent coupling parameters and the required structural reorganizations (see Figure 6c). The dipoles at the diamond/solvent interface affect this equilibrium by altering the onsite Gibbs energy term with a contribution from the electrostatic potential (ΔV\Delta V). As shown in Figure 6c and Figure 6e, the band bending accelerates a forward charge transfer process (until reaching the Marcus inverted region), but at the same time, the magnitude of the back charge transfer (BCT) rate drops exponentially. Hence, regardless of the defect type, large interfacial band bending can lead to a dynamical trapping of the charges around a site with the lower Gibbs energy. For a numerical validation, we focus on the electron fluctuations between a pair of carbon vacancies as well as on the hole fluctuations between two substitutional nitrogen defects. We note that carbon vacancies are often generated by the implantation and irradiation techniques used to create the NV centers, and substitutional N defects are present around NV centers to stabilize the negative charge state of the NV center. After determining the relevant parameters in the periodic supercells (see Methods for detail), we first analyze the possible contribution of each charge transfer reaction to the electric noise. To this end, we compare the fluctuation rates, calculated for both defect pairs in a bulk-like environment (ΔV=0\Delta V = 0). As shown in Figure 6d, the charge fluctuation rates for a pair of nitrogen defects is remarkably smaller than for a vacancy pair. This difference is attributed to a formation of an energetically unfavorable N0\mathrm{N}^{0} configuration, that hinders the charge fluctuations by large structural reorganizations (λreorg=1.89\lambda_{\mathrm{reorg}} = 1.89 eV).

Hence, substitutional N0\mathrm{N}^{0} pairs are unlikely to be the origin of electric and magnetic noise, affecting the T1T_{1} time due to charge fluctuation. By contrast, owing to a rather modest λreorg\lambda_{\mathrm{reorg}} of 0.28 eV, a vacancy pair gives rise to noise in a broad frequency range, where the respective rate constants are controlled by the separation between the active sites.

The relevant distance between a pair of vacancies is readily obtained from an exponential fit of the rate constants in Figure 6d. More specifically, we find the charge fluctuation rates, which would be relevant for an influence on the T1T_{1} time (∼0.1\sim0.1 GHz) at a separation of ∼3\sim3 nm. The molecular dynamics simulations performed by Fáv​​aro de Oliveira et al. show that such a high local density of vacancies around the region of an NV center is achieved during the nitrogen implantation due to the cascade process of the “kick-out” mechanism. [49] Using the variations of electrostatic potential from Figure 6b for the implantation depths of 5 and 12 nm, we calculate a contribution to the onsite Gibbs energies by 0.125 and 0.075 eV, respectively (see Methods for details). As shown in Figure 6e, the BCT rate at 12 nm reduces by a factor of ∼7\sim7 relative to the case of ΔV=0\Delta V = 0. Moreover, in agreement with our experimental results, the faster changes in the potential at 5 nm enhances the reduction factor to ∼19\sim19 for the shallower NV centers. Relative to pure water, the BCT rates decrease by factors of ∼10\sim10 and 3.5 for the depths of 5 nm and 12 nm, respectively. Furthermore, the proposed mechanism is consistent with the experimental results on dark spins (see Figure 5). Interestingly, our calculations point to an even larger decrease of the BCT rate at smaller distances from the interface which should translate to an even larger sensitivity. Given the favorable downwards band bending, these results call for a further optimization of the implantation parameters as well as the surface structure to fully exploit the extension of the T1T_{1} time by diamagnetic electrolyte solutions. We note that a similar impact of paramagnetic ions on the band bending is very likely but obscured by the strong magnetic interaction of the NV center with unpaired electrons leading to an overall decrease in the T1T_{1} time.

Conclusion and Outlook

We report on the effect of diamagnetic electrolyte solutions on highly dense near-surface spin defects in oxidized diamonds. Surprisingly, we observe that diamagnetic ions increase the T1T_1 relaxation time of NV centers. We demonstrate that this effect is reversible, surface sensitive and responsive to millimolar concentrations. We also find that interfacial spin defects are sensitive to diamagnetic species, anticipating their possible use as reporter spins for future optimization. Furthermore, we investigate the underlying mechanism by single and double quantum NV relaxometry experiments in combination with ab initio simulations. We propose that ions at the interface stabilize charge fluctuations between pairs of carbon vacancies and alike deep defects surrounding the NV centers. This reduces magnetic as well as electric noise at the diamond interface by a dynamical trapping of mobile electrons to a site with lower Gibbs energy.

Our findings mark an important step towards understanding the complex processes at the solid/liquid interface of an oxidized NV-diamond. Further studies will be necessary to obtain a complete understanding of the T1T_1 time increase by electrolyte solutions. For instance, electric noise at the surface could be probed with more advanced sensing schemes. [50, 51] Further exploration of diamond surface terminations, including nitrogen-termination [52] and highly ordered oxygen-termination, [21] could provide insight into how chemical groups interact with the electrolyte. However, altering the surface termination may also modify the properties of the NV-diamond (such as band bending, [53] electron affinity, [54] NV charge state, [52] surface dark spins, [55] etc.), which can, in turn, impact the NV center’s relaxation. Thus, careful consideration must be taken regarding the T1T_1 time behavior. In addition, different implantation parameters or NV creation techniques, such as helium ion implantation [56] and nitrogen delta-doping, [57] could shed light on the role of implantation-induced (vacancy) defects on the T1T_1 time. Furthermore, we encourage similar experiments with high spatial resolution or single NV centers [58, 59] to correlate the effect of electrolytes with the NV center’s local environment. Similarly, probing the influence of electrolytes on NV centers in nanodiamonds [17] should be a crucial objective.

In addition to advancing our fundamental understanding of interfacial processes on spin defects in diamond, we anticipate a range of potential applications, such as electrolyte sensing in cell biology,[60] neuroscience,[61] or electrochemistry.[62]

Methods

Sample Preparation

Two 2×2×0.52 \times2 \times0.5 mm electronic grade diamond samples (natural 13C{}^{13}\mathrm{C} abundance, Element Six) were implanted with 15N{}^{15}\mathrm{N} at an energy of 2.5 keV and 4 keV, an off-axis tilt of 7∘7^{\circ} and a fluence of 2×1012 cm−22 \times10^{12}\ \mathrm{cm}^{-2} by Innovion and annealed according to Bucher et al.[18] Before experiments are conducted, the diamonds are cleaned with a triacid cleaning protocol according to Brown et al.[38] Samples are boiled in equal parts of sulfuric, nitric and perchloric acid at a temperature of 280 °C for two hours. This cleaning procedure is also applied before the deposition of aluminium oxide (Al2O3\mathrm{Al}_{2}\mathrm{O}_{3}) on the diamond.

Preparation of Electrolyte Solutions

For the measurements where pure water is used, deionized water with a resistivity of 18.2 MΩ⋅cm18.2\ \mathrm{M}\Omega\cdot\mathrm{cm} at 25 °C (Merck Millipore) is utilized.

Sodium chloride (NaCl, Merck 106404) is prepared in a 1 M stock solution, where NaCl is dissolved in deionized water. Before the experiments, NaCl is diluted from the stock solution in steps of 1:10. The other salt solutions used within this work are prepared in the same manner.

Atomic Layer Deposition (ALD)

The 2.5 keV 15N{}^{15}\mathrm{N} implanted diamond is coated with an aluminium oxide (Al2O3\mathrm{Al}_{2}\mathrm{O}_{3}) thin film by ALD according to Liu et al.[13]. The deposition includes 10 cycles of alternated sample exposure to trimethyl aluminium (TMA) and H2O\mathrm{H}_{2}\mathrm{O}. This procedure results in a film thickness of ∼1\sim1 nm and ensures surface termination with hydroxyl groups by exposing the diamond to a remote oxygen plasma within the ALD system.[13, 63] The Al2O3\mathrm{Al}_{2}\mathrm{O}_{3} layer can be removed from the diamond surface by soaking the sample overnight in 5% NaOH solution.

Experimental Setup

The quantum sensing setup is based on a modified version of the experiment described in Bucher et al.[18] Before experiments are performed, the diamond is glued to a thin glass cover slide (48393026, VWR) together with a microfluidic device that encloses the diamond edges and covers its surface, such that a volume of ∼0.60 μL\sim0.60\,\mu\mathrm{L} of the sample liquid can be applied in a controllable way.[15] On the other side of the cover slide a 6 mm diameter glass hemisphere (TECHSPEC® N-BK7 Half-Ball Lenses, Edmund Optics) is glued, in order to improve the fluorescence light collection efficiency. The glass cover slide is then fixed on a 30 mm cage plate (CP4S, Thorlabs). This whole assembly is then positioned between two permanent magnets, that are rotated and tilted in order to align the B0B_{0} field with one of the four possible NV center orientations. The distance between the two magnets can be adjusted in order to correspond to the working magnetic field strengths B0B_{0} (in this work: 15, 316, 352 and 978 G). Initialization of the NV-ensemble is realized with a 532 nm laser (Verdi G5, Coherent) with a power of ∼250\sim250 mW (CW) after the acousto-optic modulator (AOM). The laser light is focused on the diamond by a Plano-Convex Lens (LA 1986-A-M, Thorlabs) in a total internal reflection geometry. Laser pulses are regulated by an AOM (Gooch and Housego, model 3250-220) with pulse durations of 5 μ\mus. Photoluminescence (PL) is collected and focused on a large area photodiode (OE-300-SI-10, Femto Messtechnik GmbH, Berlin, Germany) by two condenser lenses (ACL25416U-B, Thorlabs). The excitation light is filtered by a long-pass optical filter (Edge Basic 647 Long Wave Pass, Semrock) placed between the bottom condenser lens and the photodiode. The output voltage of the photodiode is digitized with a data acquisition unit (USB-6229 DAQ, National Instruments). A 500 MHz PulseBlaster card (ESR-Pro-II, Spincore) is utilized to trigger and to time the microwave and light pulses used for quantum control of the NV centers. The microwave frequencies are produced by a signal source (SynthHD, Windfreak Technologies, LLC.). Microwave phase control is obtained by a combination of a phase-shifting splitter (ZX10Q-2-27-S+, Mini-Circuits), two switches (ZASWA-2-50dRA+, Mini-Circuits) and a combiner (ZX10-2-42-S+, Mini-Circuits). The amplified microwave pulses (ZHL-16W-43-S+, Mini-Circuits) are delivered by a homebuilt microwave loop on top of the microfluidic chip. [18] The electron spin resonance (ESR) frequency is used to determine the magnetic field strength B0B_0 as well as the NV0,−1\mathrm{NV}_{0,-1} resonance frequency fNVf_{\mathrm{NV}}.

T1T_1 Relaxometry Experiments (Single and Double Quantum)

Single quantum (SQ) relaxometry experiments: To obtain a signal-to-noise ratio (SNR) as shown in Figure 1b the sequence is repeated 5,000 times for every data point. Each experiment consists of 31 data points measured in a logarithmic increasing sweep time tt to guarantee more sampling points at short times tt. Note that these parameters are also used for double quantum (DQ) relaxometry. For normalization and noise cancellation, the second half of the sequence contains a MW π0,−1\pi_{0,-1}-pulse, where the subscripts 0 and -1 indicate the transition of the spin state between ms=0m_s = 0 and ms=−1m_s = -1.[18] The spectra are then plotted as the measurement result of the first half divided by the result of the second half of the sequence.

Double quantum (DQ) relaxometry experiments: For a detailed discussion of the DQ relaxation and pulse sequence, the reader is referred to Myers et al.⁴² In short, the DQ pulse sequence (see inset of Figure 4b) consists of two consecutive measurements where MW π\pi-pulses are used to control spin state initialization and readout. In both halves of the sequence the NV center is initialized in ms=−1m_s=-1. After a sweep time tt the spin state population of either ms=−1m_s=-1 (in the first part) or ms=+1m_s=+1 (in the second part) is read out. Dividing the second by the first part yields a population ratio of the two states.

Sensitivity of T1T_1 Relaxometry on Electrolytes

Experiments to determine the sensitivity of T1T_1 relaxometry measurements on para- and diamagnetic electrolytes are conducted for MnCl2_2 and NaCl solutions using the SQ relaxometry pulse sequence. Probing each concentration results in a relaxation curve of which the T1T_1 time is determined. The T1T_1 time is then normalized to the one of water covering the diamond. Before probing any electrolyte concentration, we wash the microfluidic device with water to ensure equal starting conditions, i.e., a constant T1T_1 time for water covering the diamond. We perform each series three times resulting in a mean T1T_1 value for each concentration (see also Supplementary Note 4). Figure 2 in the main text shows the mean (normalized) T1T_1 time along with the standard deviation.

DEER Measurements

DEER spectra (see Figure 5b) are recorded by performing a spin-echo sequence on the NV center spins with a free evolution time of 1 μs1\,\mu\mathrm{s}. The duration of the MW-pulse (MWDEER\mathrm{MW}_{\mathrm{DEER}}) applied to the surface dark spins is set to 200 ns200\,\mathrm{ns} and the driving frequency (fDEERf_{\mathrm{DEER}}) is swept over 90 MHz90\,\mathrm{MHz} (from fDEER=0.84f_{\mathrm{DEER}}=0.84 to 0.93 GHz0.93\,\mathrm{GHz}). To obtain an SNR as shown in Figure 5b the sequence is repeated 10,000 times for every data point. Each experiment consists of 67 data points in equally separated frequency steps and this whole experiment is repeated four times. Referencing for noise cancellation is achieved by alternating the last MW-pulse of the spin-echo sequence from π/2\pi/2 to 3/2π3/2\pi.

Once the resonance condition for ge=2g_e=2 is found, DEER-Rabi experiments on the surface dark spins are performed by sweeping the MW-pulse duration (MWDEER\mathrm{MW}_{\mathrm{DEER}}) during the NV spin-echo (see Figure 5c) as described above. The sequence is repeated 10,000 times for every data point. Each experiment consists of 101 equally spaced data points and this whole experiment is repeated ten times. To account for MW (MWDEER_{\mathrm{DEER}}) noise, the same procedure is repeated 20 MHz off the resonance condition. The outcome of both on- and off-resonant measurements are subtracted resulting in the spectra shown in Figure 5c. After that, measurements of the surface dark spin population relaxation are carried out according to Sushkov et al. with a πds\pi_{\mathrm{ds}}-pulse length of 24 ns.[43] The sequence shown in Figure 5d is repeated 10,000 times for every data point. Each experiment consists of 21 data points in equally separated time steps. This whole experiment is then repeated 50 times. Background subtraction is achieved by performing the experiment in the same procedure without the additional MW drive (MWDEER_{\mathrm{DEER}}). Subtracting the outcome of both MW-on and MW-off measurements then yields the spectra shown in Figure 5d.

Simulation of the Diamond/Water Interface

In our simulations, we use a slab of a model diamond surface with hydrogen, hydroxyl, and ether surface terminations (see Figure S12). It is a symmetric (100) surface of ∼1.4\sim1.4 nm with a 2×12 \times1 surface reconstruction pattern, exhibiting a positive electron affinity and no surface states inside the band gap.[53] The water layer on top of the diamond (thickness ∼2\sim2 nm) was constructed as follows. First, we equilibrate 74 water molecules with the classical molecular dynamics (MD) for 5 ns in a simulation box of commensurate lateral size with the diamond slab. These calculations are done with the GROMACS software in the canonical NVT ensemble,[64] using the GROMOS 54A7 force field.[65] After that, we superimpose the water box and the diamond surface and allow for an additional equilibration step of 10 ps with the ab initio MD, as implemented in the VASP package.[66] We also incorporate ∼1.9\sim1.9 nm of vacuum together with a dipole correction scheme to eliminate the interaction with the periodic images. This yields the simulation supercell of 1.0097×1.0097×5.3 nm31.0097 \times1.0097 \times5.3\ \mathrm{nm}^{3}, which is further used in the ab initio MD calculations. Ab initio calculations are performed using the PBE functional[67] in conjunction with the D2 dispersion correction, using a projector augmented wave method with the kinetic energy cutoff of 370 eV. We note that the PBE functional provides semi-quantitative results for the electronic structure but is able to accurately yield the trends in the change of the electronic structure upon different surface terminations and environments of diamond. Further, we note that we focus on the difference in the electrostatic environment due to the interaction of the electrolyte with the surface groups, assuming no change in the microstructure of the carbon layer.

Charge Transfer Rates

We calculate the charge transfer rate with an expression from the Marcus theory, [68] given as:

kCT=2πℏ∣HAB∣214πλkBTexp⁡(−(λ+ΔG)24πλkBT)k_{CT} = \frac{2\pi}{\hbar} \lvert H_{AB}\rvert^2 \frac{1}{\sqrt{4\pi\lambda k_B T}} \exp\left(-\frac{(\lambda+\Delta G)^2}{4\pi\lambda k_B T}\right)

where HABH_{AB} is the transfer integral, λ\lambda the reorganization energy, ΔG\Delta G the Gibbs energy difference due to an external field, kBk_B the Boltzmann constant, ℏ\hbar the reduced Planck constant, and TT the temperature. The reorganization energy is determined for a single defect (either a carbon vacancy or a substitutional nitrogen) in a 1000-carbon supercell. For computing the transfer integrals as a function of distance, we use diamond supercells of different sizes, varying between 64 and 1000-carbon atoms. The reorganization energies are calculated by the four-point scheme, while the transfer integrals are estimated at a high symmetry configuration as 1/41/4 of the bandwidth along the Γ\Gamma-X direction. The contribution to the Gibbs energy is computed by solving the one dimensional Poisson equation given the experimental depth of the NV center. [69] Noteworthy, the effect from the band bending is governed by the orientation of defect pairs relative to the direction of the electric field. At a reference depth of the NV center, the maximum strength, corresponding to a change in the electrostatic potential (ΔVmax⁡\Delta V_{\max}), is reached in a parallel configuration, whilst the effect is quenched towards the orthogonal arrangement. Considering a uniform distribution of the defects in our samples, we compute an expectation value of ΔV\Delta V as ΔVmax⁡/2\Delta V_{\max}/2.

Acknowledgement

This study was funded by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) - 412351169 within the Emmy Noether program. R. Rizzato acknowledges support from the DFG Walter Benjamin Programme (Project RI 3319/1-1). D. Bucher acknowledges support from the DFG under Germany’s Excellence Strategy—EXC 2089/1—390776260 and the EXC-2111 390814868. M. Brandt acknowledges support by BMBF through project epiNV (13N15702) and the Munich Center for Quantum Science and Technology (MCQST, EXC-2111) and by Bayerisches Staatsministerium für Wissenschaft und Kunst through project IQSense via the Munich Quantum Valley (MQV). A. Gali acknowledges the Hungarian NKFIH grant No. KKP129866 of the National Excellence Program of Quantum-coherent materials project, the support for the Quantum Information National Laboratory from the Ministry of Culture and Innovation of Hungary (NKFIH grant No. 2022-2.1.1-NL-2022-00004), the EU EIC Pathfinder project ”QuMicro” (grant No. 101046911) and the EU QuantERA for the project MAESTRO. We acknowledge KIFÜ for awarding us access to computational resources based in Hungary.

Abbreviations

NV, nitrogen-vacancy; NMR, nuclear magnetic resonance; ESR, electron spin resonance; ODMR, optically detected magnetic resonance; DEER, double electron electron resonance; MW, microwave; ALD, atomic layer deposition; SQ, single quantum; DQ, double quantum; VLS, vacuum level shift; MD, molecular dynamics; BCT, back charge transfer; TMA, trimethyl aluminium; CW, continuous wave; AOM, acousto-optic modulator; PL, photoluminescence; SNR, signal-to-noise ratio; PBE, Perdew-Burke-Ernzerhof; DFT, density functional theory.

Author Contributions

D. Bucher, R. Rizzato and F. Freire-Moschovitis discovered the effect of diamagnetic electrolytes on the relaxation of NV centers. D. Bucher, R. Rizzato and F. Freire-Moschovitis designed the experiments. D. Bucher supervised the study. F. Freire-Moschovitis performed the experiments and was supported by M. Schepp for NV relaxometry. F. Freire-Moschovitis, R. Rizzato and D. Bucher analyzed the data. R. Allert built the quantum sensing setup and designed the microfluidic device. A. Gali and A. Pershin incorporated theoretical modeling and simulations. M. Brandt and L. Todenhagen helped with the charge state experiments. All authors discussed the results and contributed to the writing of the manuscript.

Additional Information

Competing interests: The authors declare no competing interests.

Data Availability

The data supporting our findings are available within the paper and the Supplementary Information. Additional relevant data are available from the corresponding author upon reasonable request.

Code Availability

The codes used for data acquisition and processing are available from the corresponding author upon reasonable request.

Supporting Information Available

Fitting details, data of additional (single and double quantum) relaxometry experiments of various electrolyte solutions and organic solvents, data of NV relaxometry measurements on differently oxidized surface terminations, data of NV charge state, coherence and dephasing measurements, data of ESR experiments at zero magnetic field, and results of DFT-PBE ab initio molecular dynamics simulations.

Supporting Information: The Role of Electrolytes in the Relaxation of Near-Surface Spin Defects in Diamond

Fitting of T1T_1 Single Quantum (SQ), Double Quantum (DQ) and Surface Dark Spin Relaxation Curves

Recorded single quantum (SQ) and double quantum (DQ) relaxation curves are fitted with a biexponential function as the T1T_1 decay exhibited two components according to prior work:[25, 27, 28, 32, 70]

C(t)=A⋅exp⁡(−1T1a⋅t)+(1−A)⋅exp⁡(−1T1b⋅t)C(t) = A \cdot\exp\left(-\frac{1}{T_{1a}} \cdot t\right) + (1-A) \cdot\exp\left(-\frac{1}{T_{1b}} \cdot t\right)

where CC is the contrast, AA is the amplitude and T1a≫T1bT_{1a} \gg T_{1b}. For completeness, relaxation times in the tables are given by both time constants. In agreement with prior work,[25, 27, 32] values of T1T_1 in the main text are only considering the longer component T1aT_{1a}. However, both time constants are longer in all cases where diamagnetic electrolytes are measured with NV relaxometry and compared to water (see Table S1). Errors and errorbars from SQ and DQ relaxation curves shown in tables or figures are standard deviations from the biexponential fit function or in case of the sensitivity experiments (see Figure 2 in the main text) the standard deviation from three consecutive measurements. T1T_1 time constants in the tables are given to three significant digits. In case of the T1,dsT_{1,\mathrm{ds}} relaxation measurements (see Figure 5d in the main text), the relaxation curve is fitted to a single exponential decay:

Electrolyte [c = 500 mM]T1aT_{1a} [μs]T1bT_{1b} [μs]
Water920 ± 170140 ± 60.0
CsF1510 ± 250200 ± 60.0
KCl1720 ± 300270 ± 90.0
KNO3_31360 ± 220240 ± 50.0
LiCl2940 ± 720930 ± 40.0
NaCl1920 ± 200170 ± 20.0
CaCl2_22920 ± 260460 ± 190
MgSO4_43600 ± 160310 ± 100
AlCl3_32070 ± 370360 ± 190
Electrolyte [c = 1 μM]T1aT_{1a} [μs]T1bT_{1b} [μs]
MnCl2_2430 ± 160140 ± 50.0
Gd(NO3_3)3_3250 ± 15.021 ± 6.00

Table S1. T1T_1 time constants (T1aT_{1a} and T1bT_{1b}) of water and measured diamagnetic electrolyte solutions (500 mM) as well as paramagnetic electrolyte solutions (1 μM) covering the diamond surface. Experiments are performed at fNV=1.88f_{\mathrm{NV}} = 1.88 GHz.

C(t)=A⋅exp⁡(−1T1,ds⋅t).C(t) = A \cdot\exp\left(-\frac{1}{T_{1,\mathrm{ds}}} \cdot t\right).
citep‘43‘{citep}`43`

T1T_1 Time Constants of Measured Electrolytes and T1T_1 Time Magnetic Field Dependence for Pure Water/NaCl (500 mM)

Table S1 and Figure S1 show the T1T_1 time constants (T1aT_{1a} and T1bT_{1b}) and T1T_1 relaxation curves of the measured electrolyte solutions in this work. Experiments are conducted with the relaxometry pulse sequence according to the main text.

T₁ relaxation curves of water and electrolyte solutions

Figure S1. T1T_1 relaxation curves of water and a-f) diamagnetic electrolyte (500 mM) solutions as well as g) and h) paramagnetic electrolyte (1 µM) solutions covering the diamond surface. Experiments are performed at fNV=1.88f_{\mathrm{NV}} = 1.88 GHz.

Further measurements of water/NaCl (500 mM) solution are performed in different magnetic fields B0B_0 (978, 352, 15 and 0 G), i.e., different resonance frequencies of the NV center’s ms=0→ms=−1m_s = 0 \to m_s = -1 transition (fNV=0.131f_{\mathrm{NV}} = 0.131, 1.88, 2.83 and 2.87 GHz). Figure S2 shows the T1aT_{1a} time constants depending on fNVf_{\mathrm{NV}} (see Supplementary Note 1 for details). In Table S2 both time constants (T1aT_{1a} and T1bT_{1b}) are listed.

T1a time constants for water and NaCl solution

Figure S2. T1aT_{1a} time constants for water and NaCl (500 mM) solution and their dependence on the NV0,−1_{0,-1} resonance frequency fNVf_{\mathrm{NV}}.

T1aT_{1a} [µs]T1bT_{1b} [µs]
fNV=0.131f_{\mathrm{NV}} = 0.131 GHz
Water1810 ± 460400 ± 60.0
NaCl 500 mM2300 ± 340670 ± 130
fNV=1.88f_{\mathrm{NV}} = 1.88 GHz
Water940 ± 180130 ± 20.0
NaCl 500 mM1990 ± 200170 ± 20.0
fNV=2.83f_{\mathrm{NV}} = 2.83 GHz
Water2660 ± 110510 ± 80.0
NaCl 500 mM3970 ± 4001210 ± 410
fNV=2.87f_{\mathrm{NV}} = 2.87 GHz
Water3460 ± 630930 ± 190
NaCl 500 mM4830 ± 7401830 ± 510

Table S2. T1T_1 time constants (T1aT_{1a} and T1bT_{1b}) for water and NaCl (500 mM) solution covering the diamond surface depending on the NV0,−1_{0,-1} resonance frequency fNVf_{\mathrm{NV}}.

NV Relaxometry Experiments with Different Organic Solvents

Following measurements are performed in order to investigate the impact of the solvent’s physical properties on NV relaxometry experiments. Therefore, we choose organic solvents with dielectric constants (κ\kappa) which differ significantly from the properties of water. [40] The diamond is covered three times alternatingly with water and the organic solvent. T1T_1 times of the solvents are then normalized to the T1T_1 time of water. Figure S3 shows that the T1T_1 time remains unaffected by the solvent.

NV relaxometry experiments showing normalized solvent relaxation times for ethyl acetate, acetonitrile, and pure water as a function of solvent dielectric constant

Figure S3. NV relaxometry experiments showing the impact of the solvent’s dielectric constant (κ\kappa). Experiments are performed at fNV=1.88f_{\mathrm{NV}} = 1.88 GHz.

NV Relaxometry Measurement Series of Para- and Diamagnetic Electrolyte Solutions in Increasing Concentrations

The NV relaxometry measurement series with paramagnetic MnCl2\mathrm{MnCl}_2 and diamagnetic NaCl\mathrm{NaCl} solutions are performed in order to determine the sensitivity of the protocol to increasing electrolyte solutions in each case. Paramagnetic MnCl2\mathrm{MnCl}_2 solutions decrease the T1T_1 time in ∼\sim nano- to micromolar concentrations with respect to water. In contrast to that, diamagnetic NaCl solutions increase the T1T_1 time in ∼\sim millimolar concentrations.

NV relaxometry measurement series with increasing concentrations of MnCl₂ and NaCl solutions

Figure S4. NV relaxometry measurement series with increasing concentrations of a) MnCl2_2 and b) NaCl solutions. Data points are T1T_1 times normalized to the T1T_1 time of water for each series. Solid lines connect the mean values of three consecutive performed series. Experiments are performed at fNV=1.88f_{\mathrm{NV}} = 1.88 GHz.

Additionally, we perform NV relaxometry series with monovalent NaCl and divalent MgSO4_4 solutions to uncover the influence of differently charged ions (see Figure S5). While the data suggests that MgSO4_4 has a more significant impact on increasing the T1T_1 time than NaCl, more data and simulations will be needed to draw a definitive conclusion regarding the effect.

NV relaxometry measurement series with increasing concentrations of NaCl and MgSO₄ solutions

Figure S5. NV relaxometry measurement series with increasing concentrations of NaCl (red) and MgSO4_4 (green) solutions. Data points are T1T_1 times normalized to the T1T_1 time of water for each series. Experiments are performed at fNV=1.88f_{\mathrm{NV}} = 1.88 GHz.

Experiments herein are conducted using the SQ relaxometry pulse sequence (see Methods for detail). We perform each series three times resulting in a mean value for each concentration.

Supplementary Note 5: NV Relaxometry Experiments with Differently Oxidized Diamond Surfaces

We perform NV relaxometry measurements with water and NaCl (500 mM) solution on two oxidized diamond surfaces that are treated with different reagents in order to investigate the effect on the T1T_1 time behavior (see Figure S6). One surface is prepared with the triacid clean procedure according to Brown [38] (see also Figure 3a in the main text), the other one using Fenton chemistry. [41] Diamonds are covered alternatingly with water and NaCl solution. Both surface treatments lead to similar results.

NV relaxometry experiments with water and NaCl solutions covering triacid-cleaned and Fenton-cleaned diamond surfaces

Figure S6. NV relaxometry experiments with water and NaCl (500 mM) solutions covering the diamond surface. Diamonds are prepared with the a) triacid clean or b) Fenton reagent. Experiments are performed at fNV=1.88f_{\mathrm{NV}} = 1.88 GHz.

NV Depth Dependence Measurements with Water/LiCl (500 mM)

NV relaxometry with water/LiCl (500 mM) covering the diamond is performed in order to investigate the impact of another diamagnetic electrolyte and to support the experiments with NaCl (500 mM) solution using differently deep NV center ensembles (implanted with 2.5 keV and 4 keV, see Figure 3b in the main text). Figure S7 and Table S3 show similar results for both NaCl and LiCl (500 mM) solution.

T1 relaxation curves of water and LiCl (500 mM) solutions for implantation energies of 2.5 keV and 4 keV

Figure S7. T1T_1 relaxation curves of water and LiCl (500 mM) solutions covering the diamond surface. Diamonds were implanted with 15N{}^{15}\mathrm{N} at an energy of a) 2.5 keV and b) 4 keV. Experiments are performed at fNV=1.88f_{\mathrm{NV}} = 1.88 GHz.

Implantation energy [keV]T1aT_{1a} [µs]T1bT_{1b} [µs]
2.5Water940 ± 180130 ± 20.0
NaCl 500 mM1920 ± 200170 ± 20.0
Water660 ± 180200 ± 50.0
LiCl 500 mM2940 ± 720930 ± 40.0
4Water1090 ± 190190 ± 30.0
NaCl 500 mM1270 ± 180220 ± 40.0
Water2750 ± 340380 ± 80.0
LiCl 500 mM2880 ± 270440 ± 90.0

Table S3. T1T_1 time constants (T1aT_{1a} and T1bT_{1b}) of water, NaCl (500 mM) and LiCl (500 mM) solution on the diamond surface depending on the nitrogen implantation energy. Experiments are performed at fNV=1.88f_{\mathrm{NV}} = 1.88 GHz.

NV Charge State, Coherence and Dephasing Measurements

We observe an increase of T1T_{1} by diamagnetic electrolyte solutions. However, it is known that NV charge state alteration (i.e., NV0↔^{0} \leftrightarrow NV−^{-}) can influence the outcome of NV relaxometry measurements.[71, 72] For that reason, we perform NV-Rabi experiments with water/NaCl (500 mM) solution (see Figure S8). Any change in the NV-Rabi contrast indicates an alteration of the NV center’s charge state. For instance, an ionization of NV−^{-} would increase the proportion of NV0^{0}, thereby raising the background fluorescence and lowering the contrast. The NV-Rabi experiments show no difference in the outcome between water and the electrolyte implying a constant charge state distribution during the measurement. Secondly, to supplement the NV-Rabi experiments, we conduct NV relaxometry with distinct optical readout of the NV0NV^0 and NV−NV^- charge states and with three different laser powers (see Figure S8 and Figure S8). Possible ionization of NV−NV^- in the dark or recombination processes would be visible as an alteration in the readout signal of the NV0NV^0 charge state (see Figure S8). [71, 72] These measurements are carried out using the first half of the relaxometry pulse sequence (i.e., without a π\pi-pulse) and with two different optical filters. The 647 nm long pass filter predominantly reads out the fluorescence from the NV−NV^- state and the 600±40600 \pm40 nm band pass filter mostly reads out the fluorescence from the NV0NV^0 state. [73] While a T1T_1 fluorescence decay curve can be extracted from the measurements with the long pass filter, no decisive change in the NV0NV^0 state is visible using the band pass filter. Probable impact of the laser power on the NV−/NV0NV^-/NV^0 ratio and a subsequent change in the T1T_1 relaxation curves is probed with relaxometry experiments using laser powers of 25, 50 and 100 μW μm−2\mu\mathrm{W}\,\mu\mathrm{m}^{-2} (see Figure S8). Both NV-Rabi and NV charge state experiments do not show an impact on NV charge state alteration on the relevant timescales of the relaxometry measurements we conduct herein.

Pulse sequences and spectra of NV charge state measurements

Figure S8. Pulse sequences and spectra of NV charge state measurements. a) NV-Rabi experiments, b) NV charge state measurements with selective readout of the NV0^{0} or the NV−^{-} state and c) T1T_{1} relaxation curves using three different laser powers.

Additionally, we perform Ramsey (NV dephasing) and T2T_2 (NV coherence) Hahn-echo experiments, whose outcome is typically affected by changes in the low frequency components of the noise (see Figure S9 and S9b). [30] Both experiments show no difference in the outcome for water or NaCl (500 mM) solution. However, we note that probable changes in this noise frequency regime might not be observable with the high-dense NV center ensemble we use in this work, since the surrounding spin-bath (e.g., P1-centers or other paramagnetic impurities) is limiting the NV dephasing and NV coherence in this case. [37, 47]

Pulse sequences and spectra of Ramsey and T2 Hahn-echo measurements

Figure S9. Pulse sequences and spectra of Ramsey and T2T_2 Hahn-echo measurements. a) Ramsey experiments performed at a 4 MHz detuned NV0,−1NV^{0,-1} resonance frequency fNVf_{\mathrm{NV}} and b) T2T_2 Hahn-echo experiments with water and NaCl (500 mM) solution covering the diamond surface at fNV=1.88f_{\mathrm{NV}} = 1.88 GHz.

Supplementary Note 8: T1T_1 Time Constants for Single Quantum and Double Quantum Experiments at 15 G and Zero Field ESR Measurements

SQ and DQ relaxation curves

Figure S10. a) SQ and b) DQ relaxation curves of water and MnCl2_2 (100 µM) solution covering the diamond. Experiments are performed at B0=15B_0 = 15 G, where the NV0,−1_{0,-1} transition is at fNV=2.83f_{\mathrm{NV}} = 2.83 GHz (corresponding to a DQ transition frequency of 80 MHz). T1,SQT_{1,\mathrm{SQ}} decreases by 80%, whereas T1,DQT_{1,\mathrm{DQ}} remains unchanged compared to water when MnCl2_2 solution covers the diamond.

Single and double quantum T1T_1 experiments of water/NaCl (500 mM) and water/MnCl2_2 (100 µM) solution covering the diamond surface are performed in order to elucidate the effect of the electrolyte on magnetic and electric field noise. In the case of the NaCl solution, both T1T_1 time constants (T1a,SQT_{1\mathrm{a,SQ}} and T1a,DQT_{1\mathrm{a,DQ}}) increase compared to water, indicating a reduction of both magnetic and electric field noise (see also Table S4). Importantly, MnCl2_2 only reduces the T1T_1 time for the SQ relaxation, whereas the DQ transition remains unaffected compared to water (see also Table S4). This indicates an exclusive impact of the paramagnetic electrolyte on magnetic field noise. However, we note that probing MnCl2_2 in higher (>100> 100 µM) concentrations would lead to a collapse of the NV center’s T1T_1 time (see also Figure 2 in the main text). Therefore, a final statement on the impact of higher concentrated paramagnetic electrolyte solutions on the DQ (as well as the SQ) relaxation cannot be made.

T1a,SQT_{1\mathrm{a,SQ}} [µs]T1a,DQT_{1\mathrm{a,DQ}} [µs]
Water2600 ± 280440 ± 24.0
NaCl 500 mM3970 ± 4001250 ± 120
Water2000 ± 340410 ± 71
MnCl2_2 100 µM390 ± 71.0390 ± 78.0

Table S4. T1T_1 time constants (T1a,SQT_{1\mathrm{a,SQ}} and T1a,DQT_{1\mathrm{a,DQ}}) for water/NaCl (500 mM) and water/MnCl2_2 (100 µM) solution covering the diamond surface. Experiments are performed at B0=15B_0 = 15 G.

Additionally, we investigate the static electric field environment of the NV center, i.e., charges within the diamond and adjacent to the NV center (e.g., N+^+ and NV−^-).[74] Therefore, we measure ESR at zero magnetic field (here the earth’s magnetic field ∼0.5\sim0.5 G), because any difference in the static electric field in the proximity of the NV center with respect to water or the electrolyte solution covering the surface would induce a shifting and/or splitting of the ms=±1m_s = \pm1 states apparent in the ESR spectra.[74] Figure S11 shows no significant change of the ESR resonance lines for the exposure of water or electrolyte solution, indicating that static electric fields do not contribute.

ESR experiments at zero magnetic field with water and NaCl solution covering the diamond surface

Figure S11. ESR experiments at zero magnetic field with water and NaCl (500 mM) solution covering the diamond surface.

Results of DFT-PBE Ab Initio Molecular Dynamics Simulations

References

  1. [1]Acosta, V. M.; Bauch, E.; Ledbetter, M. P.; Waxman, A.; Bouchard, L.-S.; Budker, D. Temperature Dependence of the Nitrogen-Vacancy Magnetic Resonance in Diamond. Physical Review Letters 2010, 104, 070801.pubmed.ncbi.nlm.nih.gov/20366868
  2. [2]Ivády, V.; Simon, T.; Maze, J. R.; Abrikosov, I. A.; Gali, A. Pressure and temperature dependence of the zero-field splitting in the ground state of NV centers in diamond: A first-principles study. Physical Review B 2014, 90, 235205.DOI
  3. [3]Teissier, J.; Barfuss, A.; Appel, P.; Neu, E.; Maletinsky, P. Strain Coupling of a Nitrogen-Vacancy Center Spin to a Diamond Mechanical Oscillator. Physical Review Letters 2014, 113, 020503.pubmed.ncbi.nlm.nih.gov/25062153
  4. [4]Dolde, F.; Fedder, H.; Doherty, M. W.; Nöbauer, T.; Rempp, F.; Balasubramanian, G.; Wolf, T.; Reinhard, F.; Hollenberg, L. C. L.; Jelezko, F. et al. Electric-field sensing using single diamond spins. Nature Physics 2011, 7, 459–463.DOI
  5. [5]Balasubramanian, G.; Chan, I. Y.; Kolesov, R.; Al-Hmoud, M.; Tisler, J.; Shin, C.; Kim, C.; Wojcik, A.; Hemmer, P. R.; Krueger, A. et al. Nanoscale imaging magnetometry with diamond spins under ambient conditions. Nature 2008, 455, 648–651.DOI
  6. [6]Maze, J. R.; Stanwix, P. L.; Hodges, J. S.; Hong, S.; Taylor, J. M.; Cappellaro, P.; Jiang, L.; Dutt, M. V. G.; Togan, E.; Zibrov, A. S. et al. Nanoscale magnetic sensing with an individual electronic spin in diamond. Nature 2008, 455, 644–647.DOI
  7. [7]Glenn, D. R.; Lee, K.; Park, H.; Weissleder, R.; Yacoby, A.; Lukin, M. D.; Lee, H.; Walsworth, R. L.; Connolly, C. B. Single-cell magnetic imaging using a quantum diamond microscope. Nature Methods 2015, 12, 736–738.DOI
  8. [8]Lovchinsky, I.; Sushkov, A. O.; Urbach, E.; de Leon, N. P.; Choi, S.; De Greve, K.; Evans, R.; Gertner, R.; Bersin, E.; Muller, C. et al. Nuclear magnetic resonance detection and spectroscopy of single proteins using quantum logic. Science 2016, 351, 836–841.DOI
  9. [9]Müller, C.; Kong, X.; Cai, J.-M.; Melentijević, K.; Stacey, A.; Markham, M.; Twitchen, D.; Isoya, J.; Pezzagna, S.; Meijer, J. et al. Nuclear magnetic resonance spectroscopy with single spin sensitivity. Nature Communications 2014, 5, 4703.DOI
  10. [10]Sushkov, A. O.; Lovchinsky, I.; Chisholm, N.; Walsworth, R. L.; Park, H.; Lukin, M. D. Magnetic Resonance Detection of Individual Proton Spins Using Quantum Reporters. Physical Review Letters 2014, 113, 197601.pubmed.ncbi.nlm.nih.gov/25415924
  11. [11]Bucher, D. B. Principles of nano-and microscale NMR-spectroscopy with NV-diamond sensors. eMagRes 2019, 8, 363–370.DOI
  12. [12]Lovchinsky, I.; Sanchez-Yamagishi, J. D.; Urbach, E. K.; Choi, S.; Fang, S.; Andersen, T. I.; Watanabe, K.; Taniguchi, T.; Bylinskii, A.; Kaxiras, E. et al. Magnetic resonance spectroscopy of an atomically thin material using a single-spin qubit. Science 2017, 355, 503–507.DOI
  13. [13]Liu, K. S.; Henning, A.; Heindl, M. W.; Allert, R. D.; Bartl, J. D.; Sharp, I. D.; Rizzato, R.; Bucher, D. B. Surface NMR using quantum sensors in diamond. Proceedings of the National Academy of Sciences 2022, 119, e2111607119.DOI
  14. [14]Allert, R. D.; Briegel, K. D.; Bucher, D. B. Advances in nano- and microscale NMR spectroscopy using diamond quantum sensors. Chemical Communications 2022, 58, 8165–8181.arxiv.org/abs/2205.12178
  15. [15]Allert, R. D.; Bruckmaier, F.; Neuling, N. R.; Freire-Moschovitis, F. A.; Liu, K. S.; Schrepel, C.; Schätzle, P.; Knittel, P.; Hermans, M.; Bucher, D. B. Microfluidic quantum sensing platform for lab-on-a-chip applications. Lab on a Chip 2022, 22, 4831–4840.arxiv.org/abs/2209.01651
  16. [16]Shi, F.; Zhang, Q.; Wang, P.; Sun, H.; Wang, J.; Rong, X.; Chen, M.; Ju, C.; Reinhard, F.; Chen, H. et al. Single-protein spin resonance spectroscopy under ambient conditions. Science 2015, 347, 1135–1138.DOI
  17. [17]Schirhagl, R.; Chang, K.; Loretz, M.; Degen, C. L. Nitrogen-Vacancy Centers in Diamond: Nanoscale Sensors for Physics and Biology. Annual Review of Physical Chemistry 2014, 65, 83–105.DOI
  18. [18]Bucher, D. B.; Aude Craik, D. P.; Backlund, M. P.; Turner, M. J.; Ben Dor, O.; Glenn, D. R.; Walsworth, R. L. Quantum diamond spectrometer for nanoscale NMR and ESR spectroscopy. Nature Protocols 2019, 14, 2707–2747.DOI
  19. [19]Kim, M.; Mamin, H. J.; Sherwood, M. H.; Ohno, K.; Awschalom, D. D.; Rugar, D. Decoherence of Near-Surface Nitrogen-Vacancy Centers Due to Electric Field Noise. Physical Review Letters 2015, 115, 087602.DOI
  20. [20]Stacey, A.; Dontschuk, N.; Chou, J.; Broadway, D. A.; Schenk, A. K.; Sear, M. J.; Tetienne, J.; Hoffman, A.; Prawer, S.; Pakes, C. I. et al. Evidence for Primal sp² Defects at the Diamond Surface: Candidates for Electron Trapping and Noise Sources. Advanced Materials Interfaces 2019, 6, 1801449.arxiv.org/abs/1807.02946
  21. [21]Sangtawesin, S.; Dwyer, B. L.; Srinivasan, S.; Allred, J. J.; Rodgers, L. V. H.; De Greve, K.; Stacey, A.; Dontschuk, N.; O’Donnell, K. M.; Hu, D. et al. Origins of Diamond Surface Noise Probed by Correlating Single-Spin Measurements with Surface Spectroscopy. Physical Review X 2019, 9, 031052.
  22. [22]Romach, Y.; Müller, C.; Unden, T.; Rogers, L. J.; Isoda, T.; Itoh, K. M.; Markham, M.; Stacey, A.; Meijer, J.; Pezzagna, S. et al. Spectroscopy of Surface-Induced Noise Using Shallow Spins in Diamond. Physical Review Letters 2015, 114, 017601.pubmed.ncbi.nlm.nih.gov/25615501
  23. [23]Chrostoski, P.; Sadeghpour, H. R.; Santamore, D. H. Electric Noise Spectra of a Near- Surface Nitrogen-Vacancy Center in Diamond with a Protective Layer. Physical Review Applied 2018, 10, 064056.
  24. [24]Degen, C. L.; Reinhard, F.; Cappellaro, P. Quantum sensing. Reviews of Modern Physics 2017, 89, 035002.DOI
  25. [25]Steinert, S.; Ziem, F.; Hall, L. T.; Zappe, A.; Schweikert, M.; Götz, N.; Aird, A.; Balasubramanian, G.; Hollenberg, L.; Wrachtrup, J. Magnetic spin imaging under ambient conditions with sub-cellular resolution. Nature Communications 2013, 4, 1607.DOI
  26. [26]Mzyk, A.; Sigaeva, A.; Schirhagl, R. Relaxometry with Nitrogen Vacancy (NV) Centers in Diamond. Accounts of Chemical Research 2022, 55, 3572–3580.DOI
  27. [27]Perona Martínez, F.; Nusantara, A. C.; Chipaux, M.; Padamati, S. K.; Schirhagl, R. Nanodiamond Relaxometry-Based Detection of Free-Radical Species When Produced in Chemical Reactions in Biologically Relevant Conditions. ACS Sensors 2020, 5, 3862–3869.DOI
  28. [28]Li, R.; Vedelaar, T.; Mzyk, A.; Morita, A.; Padamati, S. K.; Schirhagl, R. Following Polymer Degradation with Nanodiamond Magnetometry. ACS Sensors 2022, 7, 123–130.DOI
  29. [29]Jarmola, A.; Acosta, V. M.; Jensen, K.; Chemerisov, S.; Budker, D. Temperature- and Magnetic-Field-Dependent Longitudinal Spin Relaxation in Nitrogen-Vacancy Ensembles in Diamond. Physical Review Letters 2012, 108, 197601.pubmed.ncbi.nlm.nih.gov/23003089
  30. [30]Rosskopf, T.; Dussaux, A.; Ohashi, K.; Loretz, M.; Schirhagl, R.; Watanabe, H.; Shikata, S.; Itoh, K. M.; Degen, C. L. Investigation of Surface Magnetic Noise by Shallow Spins in Diamond. Physical Review Letters 2014, 112, 147602.pubmed.ncbi.nlm.nih.gov/24766015
  31. [31]Nie, L.; Nusantara, A. C.; Damle, V. G.; Baranov, M. V.; Chipaux, M.; Reyes-San- Martin, C.; Hamoh, T.; Epperla, C. P.; Guricova, M.; Cigler, P. et al. Quantum Sensing of Free Radicals in Primary Human Dendritic Cells. Nano Letters 2022, 22, 1818–1825.
  32. [32]Ziem, F. C.; Götz, N. S.; Zappe, A.; Steinert, S.; Wrachtrup, J. Highly Sensitive Detection of Physiological Spins in a Microfluidic Device. Nano Letters 2013, 13, 4093–4098.DOI
  33. [33]Ermakova, A.; Pramanik, G.; Cai, J.-M.; Algara-Siller, G.; Kaiser, U.; Weil, T.; Tzeng, Y.-K.; Chang, H. C.; McGuinness, L. P.; Plenio, M. B. et al. Detection of a Few Metallo-Protein Molecules Using Color Centers in Nanodiamonds. Nano Letters 2013, 13, 3305–3309.DOI
  34. [34]Fujisaku, T.; Tanabe, R.; Onoda, S.; Kubota, R.; Segawa, T. F.; So, F. T.-K.; Ohshima, T.; Hamachi, I.; Shirakawa, M.; Igarashi, R. pH Nanosensor Using Electronic Spins in Diamond. ACS Nano 2019, 13, 11726–11732.DOI
  35. [35]Simpson, D. A.; Ryan, R. G.; Hall, L. T.; Panchenko, E.; Drew, S. C.; Petrou, S.; Donnelly, P. S.; Mulvaney, P.; Hollenberg, L. C. L. Electron paramagnetic resonance microscopy using spins in diamond under ambient conditions. Nature Communications 2017, 8, 458.DOI
  36. [36]Pham, L. M.; DeVience, S. J.; Casola, F.; Lovchinsky, I.; Sushkov, A. O.; Bersin, E.; Lee, J.; Urbach, E.; Cappellaro, P.; Park, H. et al. NMR technique for determining the depth of shallow nitrogen-vacancy centers in diamond. Physical Review B 2016, 93, 045425.DOI
  37. [37]Henshaw, J.; Kehayias, P.; Saleh Ziabarı, M.; Titze, M.; Morrissette, E.; Watanabe, K.; Taniguchi, T.; Li, J. I. A.; Acosta, V. M.; Bielejec, E. S. et al. Nanoscale solid-state nuclear quadrupole resonance spectroscopy using depth-optimized nitrogen-vacancy ensembles in diamond. Applied Physics Letters 2022, 120, 174002.DOI
  38. [38]Brown, K. J.; Chartier, E.; Sweet, E. M.; Hopper, D. A.; Bassett, L. C. Cleaning diamond surfaces using boiling acid treatment in a standard laboratory chemical hood. Journal of Chemical Health & Safety 2019, 26, 40–44.
  39. [39]Li, C.; Zhang, X.; Oliveira, E. F.; Puthirath, A. B.; Neupane, M. R.; Weil, J. D.; Birdwell, A. G.; Ivanov, T. G.; Kong, S.; Gray, T. et al. Systematic comparison of various oxidation treatments on diamond surface. Carbon 2021, 182, 725–734.DOI
  40. [40]Seyferth, D. Organic Solvents. Physical Properties and Methods of Purification. Fourth Edition. Volume 11 of Weissberger’s ”Techniques of Chemistry”. Organometallics 1987, 6, 1375–1376.DOI
  41. [41]Martín, R.; Heydorn, P. C.; Alvaro, M.; Garcia, H. General Strategy for High-Density Covalent Functionalization of Diamond Nanoparticles Using Fenton Chemistry. Chemistry of Materials 2009, 21, 4505–4514.DOI
  42. [42]Myers, B. A.; Ariyaratne, A.; Jayich, A. C. B. Double-Quantum Spin-Relaxation Limits to Coherence of Near-Surface Nitrogen-Vacancy Centers. Physical Review Letters 2017, 118, 197201.DOI
  43. [43]Sushkov, A. O.; Lovchinsky, I.; Chisholm, N.; Walsworth, R. L.; Park, H.; Lukin, M. D. Magnetic Resonance Detection of Individual Proton Spins Using Quantum Reporters. Physical Review Letters 2014, 113, 197601.pubmed.ncbi.nlm.nih.gov/25415924
  44. [44]Schlipf, L.; Oeckinghaus, T.; Xu, K.; Dasari, D. B. R.; Zappe, A.; de Oliveira, F. F.; Kern, B.; Azarkh, M.; Drescher, M.; Ternes, M. et al. A molecular quantum spin network controlled by a single qubit. Science Advances 2017, 3.DOI
  45. [45]Mamin, H. J.; Sherwood, M. H.; Rugar, D. Detecting external electron spins using nitrogen-vacancy centers. Physical Review B 2012, 86, 195422.DOI
  46. [46]Bluvstein, D.; Zhang, Z.; McLellan, C. A.; Williams, N. R.; Jayich, A. C. B. Extending the Quantum Coherence of a Near-Surface Qubit by Coherently Driving the Paramagnetic Surface Environment. Physical Review Letters 2019, 123, 146804.
  47. [47]Barry, J. F.; Schloss, J. M.; Bauch, E.; Turner, M. J.; Hart, C. A.; Pham, L. M.; Walsworth, R. L. Sensitivity optimization for NV-diamond magnetometry. Reviews of Modern Physics 2020, 92, 015004.DOI
  48. [48]Zhang, Z.; Joos, M.; Bluvstein, D.; Lyu, Y.; Jayich, A. C. B. Reporter-Spin-Assisted T₁ Relaxometry. Physical Review Applied 2023, 19, L031004.arxiv.org/abs/2208.11470
  49. [49]Fávaro de Oliveira, F.; Antonov, D.; Wang, Y.; Neumann, P.; Momzemzadeh, S. A.; Häußermann, T.; Pasquarelli, A.; Denisenko, A.; Wrachtrup, J. Tailoring spin defects in diamond by lattice charging. Nature Communications 2017, 8, 15409.DOI
  50. [50]Li, R.; Kong, F.; Zhao, P.; Cheng, Z.; Qin, Z.; Wang, M.; Zhang, Q.; Wang, P.; Wang, Y.; Shi, F. et al. Nanoscale Electrometry Based on a Magnetic-Field-Resistant Spin Sensor. Physical Review Letters 2020, 124, 247701.DOI
  51. [51]Cheng, Z.; Ye, X.; Wu, J.; Yu, P.; Wang, C.-J.; Wang, M.; Duan, C.-K.; Wang, Y.; Shi, F.; Tian, C. et al. Radio-Frequency Electric Field Sensing Based on a Single Solid-State Spin. Physical Review Applied 2023, 19, 014057.DOI
  52. [52]Kawai, S.; Yamano, H.; Sonoda, T.; Kato, K.; Buendia, J. J.; Kageura, T.; Fukuda, R.; Okada, T.; Tanii, T.; Higuchi, T. et al. Nitrogen-Terminated Diamond Surface for Nanoscale NMR by Shallow Nitrogen-Vacancy Centers. The Journal of Physical Chemistry C 2019, 123, 3594–3604.DOI
  53. [53]Kaviani, M.; Deák, P.; Aradi, B.; Frauenheim, T.; Chou, J.-P.; Gali, A. Proper Surface Termination for Luminescent Near-Surface NV Centers in Diamond. Nano Letters 2014, 14, 4772–4777.DOI
  54. [54]Cui, S.; Hu, E. L. Increased negatively charged nitrogen-vacancy centers in fluorinated diamond. Applied Physics Letters 2013, 103, 051603.DOI
  55. [55]Janitz, E.; Herb, K.; Völker, L. A.; Huxter, W. S.; Degen, C. L.; Abendroth, J. M. Diamond surface engineering for molecular sensing with nitrogen—vacancy centers. Journal of Materials Chemistry C 2022, 10, 13533–13569.DOI
  56. [56]Huang, Z.; Li, W.-D.; Santori, C.; Acosta, V. M.; Faraon, A.; Ishikawa, T.; Wu, W.; Winston, D.; Williams, R. S.; Beausoleil, R. G. Diamond nitrogen-vacancy centers created by scanning focused helium ion beam and annealing. Applied Physics Letters 2013, 103, 081906.DOI
  57. [57]Ohno, K.; Heremans, F. J.; Bassett, L. C.; Myers, B. A.; Toyli, D. M.; Jayich, A. C. B.; Palmstrøm, C. J.; Awschalom, D. D. Engineering shallow spins in diamond with nitrogen delta-doping. Applied Physics Letters 2012, 101, 082413.DOI
  58. [58]Zheng, W.; Bian, K.; Chen, X.; Shen, Y.; Zhang, S.; Stöhr, R.; Denisenko, A.; Wrachtrup, J.; Yang, S.; Jiang, Y. Coherence enhancement of solid-state qubits by local manipulation of the electron spin bath. Nature Physics 2022, 18, 1317–1323.
  59. [59]Dwyer, B. L.; Rodgers, L. V.; Urbach, E. K.; Bluvstein, D.; Sangtawesin, S.; Zhou, H.; Nassab, Y.; Fitzpatrick, M.; Yuan, Z.; Greve, K. D. et al. Probing Spin Dynamics on Diamond Surfaces Using a Single Quantum Sensor. PRX Quantum 2022, 3, 040328.arxiv.org/abs/2103.12757
  60. [60]Sigaeva, A.; Norouzi, N.; Schirhagl, R. Intracellular Relaxometry, Challenges, and Future Directions. ACS Central Science 2022, 8, 1484–1489.DOI
  61. [61]Hall, L. T.; Hill, C. D.; Cole, J. H.; Städler, B.; Caruso, F.; Mulvaney, P.; Wrachtrup, J.; Hollenberg, L. C. L. Monitoring ion-channel function in real time through quantum decoherence. Proceedings of the National Academy of Sciences 2010, 107, 18777–18782.DOI
  62. [62]Castelletto, S.; Boretti, A. Challenges and prospects of in situ nuclear magnetic resonance for electrochemistry devices. Materials Today Energy 2023, 31, 101210.DOI
  63. [63]Henning, A.; Bartl, J. D.; Zeidler, A.; Qian, S.; Bienek, O.; Jiang, C.; Paulus, C.; Rieger, B.; Stutzmann, M.; Sharp, I. D. Aluminum Oxide at the Monolayer Limit via Oxidant-Free Plasma-Assisted Atomic Layer Deposition on GaN. Advanced Functional Materials 2021, 31, 2101441.arxiv.org/abs/2102.03642
  64. [64]Berendsen, H.; van der Spoel, D.; van Drunen, R. GROMACS: A message-passing parallel molecular dynamics implementation. Computer Physics Communications 1995, 91, 43–56.DOI
  65. [65]Schmid, N.; Eichenberger, A. P.; Choutko, A.; Riniker, S.; Winger, M.; Mark, A. E.; van Gunsteren, W. F. Definition and testing of the GROMOS force-field versions 54A7 and 54B7. European Biophysics Journal 2011, 40, 843–856.DOI
  66. [66]Kresse, G.; Furthmüller, J. Efficient iterative schemes for ab initio total-energy calculations using a plane-wave basis set. Physical Review B 1996, 54, 11169–11186.pubmed.ncbi.nlm.nih.gov/9984901
  67. [67]Perdew, J. P.; Burke, K.; Ernzerhof, M. Generalized Gradient Approximation Made Simple. Physical Review Letters 1996, 77, 3865–3868.pubmed.ncbi.nlm.nih.gov/10062328
  68. [68]Marcus, R. A. On the Theory of Oxidation-Reduction Reactions Involving Electron Transfer. I. The Journal of Chemical Physics 1956, 24, 966–978.DOI
  69. [69]Broadway, D. A.; Dontschuk, N.; Tsai, A.; Lillie, S. E.; Lew, C. T.-K.; McCallum, J. C.; Johnson, B. C.; Doherty, M. W.; Stacey, A.; Hollenberg, L. C. L. et al. Spatial mapping of band bending in semiconductor devices using in situ quantum sensors. Nature Electronics 2018, 1, 502–507.DOI
  70. [70]Rioux, J. A.; Levesque, I. R.; Rutt, B. K. Biexponential longitudinal relaxation in white matter: Characterization and impact on T1 mapping with IR-FSE and MP2RAGE. Magnetic Resonance in Medicine 2016, 75, 2265–2277.
  71. [71]Bluvstein, D.; Zhang, Z.; Jayich, A. C. B. Identifying and Mitigating Charge Instabilities in Shallow Diamond Nitrogen-Vacancy Centers. Physical Review Letters 2019, 122, 076101.DOI
  72. [72]Dhomkar, S.; Jayakumar, H.; Zangara, P. R.; Meriles, C. A. Charge Dynamics in near-Surface, Variable-Density Ensembles of Nitrogen-Vacancy Centers in Diamond. Nano Letters 2018, 18, 4046–4052.DOI
  73. [73]Doherty, M. W.; Manson, N. B.; Delaney, P.; Jelezko, F.; Wrachtrup, J.; Hollenberg, L. C. The nitrogen-vacancy colour centre in diamond. Physics Reports 2013, 528, 1–45.DOI
  74. [74]Mittiga, T.; Hsieh, S.; Zu, C.; Kobrin, B.; Machado, F.; Bhattacharyya, P.; Rui, N. Z.; Jarmola, A.; Choi, S.; Budker, D. et al. Imaging the Local Charge Environment of Nitrogen-Vacancy Centers in Diamond. Physical Review Letters 2018, 121, 246402.DOI

Paper details

vlnc:W_gjxsnpqd
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 9

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents