betaFeedback

WorksPhysics and Astronomy

Voltage-Enhanced Photorefractive Hysteresis in Thin-Film Lithium Niobate Photonic-Crystal Cavities

Abstract

We observe voltage-enhanced photorefractive hysteresis in thin-film lithium niobate nanocavities, causing the resonance to appear at different wavelengths during increasing- and decreasing-wavelength laser scans. Their separation grows with bias magnitude and optical power, but depends weakly on scan speed over 1-200 nm/s. A quasi-static surface-trap model links voltage-biased carrier transport to asymmetric trapping, whose space-charge field shifts the resonance through the Pockels effect. The model captures this hysteresis across three cavities through switching between stable steady states. Space-charge feedback opposes further carrier separation, limiting the hysteresis gap. The model informs photorefractive mitigation and resonance control in integrated electro-optic devices.

Introduction

Thin-film lithium niobate (TFLN) has emerged as an increasingly mature platform for integrated electro-optics: its large Pockels coefficient enables fast, low-voltage modulation, its wide transparency window supports large optical bandwidth, and wafer-scale nanofabrication makes dense integration practical [1, 2, 3]. These properties have enabled the demonstration of modulators with bandwidths reaching 100 GHz [1], broadband frequency combs [4, 5], and microwave-to-optical transducers for quantum interconnects [6, 7]. Advances in lithium niobate nanofabrication [3] have extended the TFLN platform to include nanostructured resonators such as photonic-crystal cavities (PhCCs). PhCCs, by combining wavelength-scale mode volumes with high quality factors, strongly enhance intracavity optical fields, enabling nonlinear frequency conversion [8], compact electro-optic modulators [9, 10], and photonic interconnects [11].

However, the same intracavity field enhancement that enables these applications also makes PhCCs particularly susceptible to the photorefractive (PR) effect [12]. The PR effect arises when absorbed photons excite free carriers that drift under internal and applied electric fields and fill trap sites asymmetrically, building a space-charge electric field [12, 13]; in bulk crystals these traps are dopant defects, while in nanophotonic TFLN devices surface and dielectric-interface traps can play an important role [14, 15]. The space-charge field shifts the optical resonance via the Pockels effect. Feedback between the intracavity intensity and trap occupation can support multiple stable steady states at the same laser wavelength. These states can be probed by measuring optical transmission while sweeping the laser wavelength across the resonance. As the wavelength changes, the cavity follows a continuous sequence of stable states, called a branch, until that branch loses stability and the cavity switches to another. Opposite sweep directions can follow different branches and switch at different wavelengths, producing hysteresis even in the quasi-static limit. History-dependent resonance shifts can compromise resonance-voltage calibration [16], disrupt wavelength-locking loops [17], and introduce uncertainty into quantum protocols that assume a fixed cavity coupling strength.

Photorefractive effects on cavity resonances have been reported across many TFLN resonator geometries. The effect has been characterized as a function of wavelength and temperature in whispering-gallery resonators [17, 18], and shown to produce full-linewidth resonance shifts at intracavity photon numbers of only a few in photonic-crystal cavities [19, 20]. While the PR effect is fundamentally electrical in origin, its response under an externally applied electric field has not been previously systematically studied in integrated TFLN resonators. Without an applied bias, bulk photovoltaic effect can provide an internal field that biases carrier migration [21]. An applied voltage changes how photogenerated carriers fill the traps, altering the photorefractive shift of the cavity resonance.

Increasing the bias magnitude widens the gap between resonance wavelengths measured during increasing- and decreasing-wavelength laser scans. We interpret this hysteresis with a surface-trap photorefractive (STPR) model. The cavities are part of a device designed for three-port pairwise optical routing [11]. The space-charge field shifts the cavity resonance through the Pockels effect and feeds back on the drift of photogenerated carriers. The model reproduces measurements from three cavities fitted independently. We also test shared-parameter fits across the three cavities and, separately, across laser scan speeds of $1−-200nm s−1\mathrm{nm}\,\mathrm{s}^{-1} for C1C_1. These measurements do not determine the absolute trapping rates.

Device and Experimental Observations

We use the three photonic-crystal cavities of a 3×33 \times3 interferometric switch to study how applied voltage changes photorefractive hysteresis. We apply DC biases so that the cavity resonances are sufficiently separated in wavelength for each cavity to be characterized independently. Figure 1 shows the device and illustrates how we observe hysteresis by comparing transmission spectra from opposite laser scan directions.

Device geometry and voltage-dependent optical response

Figure 1. Device geometry and voltage-dependent optical response. (a) Perspective view of the TFLN photonic-crystal cavity and lateral electrodes; the upper inset shows a micrograph of the photonic crystal, and the lower inset shows the full 3×33 \times3 MMI device with tunable cavities C1C_1, C2C_2, and C3C_3. Each cavity has a separately addressable electrode for voltage tuning; the electrodes are omitted from the inset for clarity. (b) Cross-section of the oxide-clad rib waveguide and transverse applied field. (c) Normalized, vertically offset raw spectra of cavity C1C_1 at fixed input power and scan speed. Solid and dashed traces denote increasing- and decreasing-wavelength sweeps, respectively. Their overall displacement shows electro-optic tuning, while the separation within each pair shows photorefractive hysteresis.

Device Structure

The switch was fabricated on an x-cut TFLN platform (600600 nm LiNbO3_3 on 4.74.7 μ\mum buried SiO2_2 on silicon, clad with silicon dioxide). Its three arms terminate in photonic-crystal nanobeam cavities C1C_1, C2C_2, and C3C_3. The switch provides independent optical access to each cavity’s resonance. Light enters through a tapered waveguide into a cavity section where the beam width is gradually modulated to form a localized resonant mode, then reflects back off a photonic-crystal mirror Figure 1a. More information on the full device can be found in [11]. Lateral gold electrodes with a spacing of 6.86.8 μ\mum Figure 1b apply a DC bias, held fixed during each laser scan. The bias on the swept cavity ranges from −30-30 to +30+30 V. At the central wavelength λ0≈1541.59\lambda_0 \approx1541.59 nm, a linear fit to the low-power voltage sweep gives an effective quasi-static tuning magnitude ∣dν/dV∣=1.92±0.06|d\nu/dV| = 1.92 \pm0.06 GHz V−1^{-1} (∣dλ/dV∣≈(15.2±0.5)|d\lambda/dV| \approx(15.2 \pm0.5) pm V−1^{-1}) [11]. To determine each cavity’s loaded quality factor, we jointly fit its three output spectra at the two lowest input powers. The fits share a resonance wavelength and linewidth while allowing different asymmetric lineshapes caused by interference with the other arms. This gives loaded quality factors Q≈5.4×104Q \approx5.4 \times10^4, 5.0×1045.0 \times10^4, and 5.1×1045.1 \times10^4 for C1C_1–C3C_3, respectively, corresponding to full widths at half maximum of approximately 2828, 3131, and 3030 pm.

Measurement Protocol

We swept a tunable continuous-wave laser across the cavity resonances in both wavelength directions and recorded a full transmission spectrum for each sweep. We define the signed scan rate as λ˙≡dλ/dt\dot{\lambda} \equiv\mathrm{d}\lambda/\mathrm{d}t, positive for increasing wavelength and negative for decreasing wavelength. The scan speed ∣λ˙∣|\dot{\lambda}| ranged from 1 to 200 nm s−1200\ \mathrm{nm}\,\mathrm{s}^{-1}. After subtracting the common spectral background, we use local Fano fits to help identify the cavity feature and track its wavelength shift across neighboring voltage settings. We take the wavelength where the measured transmission rises most steeply as the resonance position. The extraction procedure, exclusions, and validation are detailed in Supplementary Note 4.

For each of the three cavities, we recorded transmission spectra at laser scan speeds of 2, 5, and 20 nm s−120\ \mathrm{nm}\,\mathrm{s}^{-1}, using 16 voltage settings from −30-30 to +30+30 V in 4 V increments. We refer to these measurements as the three-cavity dataset. We repeated these measurements at five source powers of −14-14, −9-9, −4-4, +1+1, and +6+6 dBm, corresponding to estimated cavity-arm input powers of −26.8-26.8, −21.8-21.8, −16.8-16.8, −11.8-11.8, and −6.8-6.8 dBm. The conversion assumes an 8 dB grating-coupler loss and the equal three-way split of the 3 × 3 multimode interferometer (MMI), 10 log10_{10} 3 ≈ 4.8 dB. Each voltage step was followed by a 0.5 s settling time before the paired wavelength scans. Further acquisition timing is given in Supplementary Note 1. We applied DC bias to cavities C2C_2 and C3C_3 to detune their resonances and spectrally isolate the response of cavity C1C_1. The separately acquired scan-speed dataset contains measurements of C1C_1 at 1, 10, 50, and 200 nm s−1200\ \mathrm{nm}\,\mathrm{s}^{-1}, using the same five input powers and 11 voltage settings from −30-30 to +30+30 V in 6 V increments. We use the three-cavity dataset for the independent cavity fits. For C1C_1, we also combine both datasets in a joint fit across all seven scan speeds. Separately, we test whether the physical parameters determined from the three-cavity dataset describe the scan-speed dataset. We retain those physical parameters and use the two lowest input powers to determine a common electro-optic tuning coefficient rVr_V for all four additional scan speeds and a separate reference wavelength λ0\lambda_0 for each acquisition. Here λ0\lambda_0 is the cavity resonance wavelength at zero applied voltage in the absence of photorefraction. We then compare the model with the three higher powers without further fitting. Figure 1(c) shows representative raw transmission spectra across an 11-step voltage sweep, directly illustrating the resonance shift and sweep-direction hysteresis before any extraction or fitting is applied.

Key Experimental Observations

Figure 1(c) shows the voltage-enhanced photorefractive hysteresis for cavity C1C_1 at a representative estimated cavity-arm input power (−16.8-16.8 dBm). The resonance wavelengths extracted from increasing-wavelength sweeps (λres↑\lambda_{\mathrm{res}}^{\uparrow}) and decreasing-wavelength sweeps (λres↓\lambda_{\mathrm{res}}^{\downarrow}) differ at fixed VappV_{\mathrm{app}}, producing a hysteresis gap Δλ=λres↑−λres↓\Delta\lambda= \lambda_{\mathrm{res}}^{\uparrow} - \lambda_{\mathrm{res}}^{\downarrow} that reaches tens of picometers. The magnitude of the gap generally increases with ∣Vapp∣\lvert V_{\mathrm{app}}\rvert, approximately linearly above about 10 V, without evident saturation up to 30 V. The hysteresis gap is small near zero bias and increases substantially under applied voltage. The gap magnitude also generally increases with optical input power. The measured range does not show a clear plateau and therefore does not establish a saturation power.

Surface-Trap Photorefractive Model

To explain why applied voltage enhances the measured hysteresis, we model how the electric field biases carrier trapping and how the trapped charge shifts the cavity resonance. We then use the steady states of the trap equations to describe why opposite laser scan directions can produce different resonance wavelengths.

Physical Picture

We develop a surface-trap reduction of the Kukhtarev–Vinetskii band-transport model [13] tailored to the TFLN PhCC geometry. Photogenerated carriers drift in the net transverse electric field and diffuse across the waveguide. Surface traps at the etched sidewalls capture the carriers, and unequal trapping on the two sides builds a space-charge dipole. Figure 2(a–Figure 2p) shows how the space-charge dipole shifts the cavity resonance differently in the two scan directions. Panel (q) shows how these mechanisms relate in the STPR model. Figure 2(a,Figure 2e) shows the up-sweep before the laser reaches resonance, with negligible carrier generation and little deviation from the bare resonance. As the laser approaches resonance, (b,f), rising intracavity power generates carriers that load the sidewall traps and build a space-charge dipole, which pulls the resonance toward the scanning laser and compresses the observed lineshape, (c,g). Once the laser has swept past resonance, (d,h), the intracavity power drops, carrier generation falls off, and the resonance recoils back toward its unperturbed position. Figure 2(i–Figure 2p) shows the down-sweep undergoing the same sequence in reverse (i,m before resonance; j,n approaching; k,o at resonance; l,p after), except the dipole now pushes the resonance away from the laser instead of toward it, stretching rather than compressing the lineshape. For the illustrated positive-bias case, the net effect of this screening is that the observed resonance sits at shorter wavelength than the bare resonance. The physical picture is formalized in the model of Figure 2(q): the effective optical drive PeffP_{\mathrm{eff}} sets the photocarrier generation rate G=g0PeffG = g_0 P_{\mathrm{eff}}, the resulting carrier partition is described by the asymmetry δ=p+−p−\delta= p_+ - p_-, where p+p_+ and p−p_- are the fractions of generated carriers reaching the two sidewalls. The trap occupancies s+s_+, s−s_- follow Shockley–Read–Hall (SRH) kinetics. Their difference Δs=s+−s−\Delta s = s_+ - s_- determines the modeled space-charge field, which in turn affects the optical resonance and carrier drift. For the fitted scans, we solve these rate equations at steady state, self-consistently with the cavity response. In this steady-state description, opposite scan directions can reach different equilibrium states at the same laser wavelength.

Figure 2. Surface-trap photorefractive mechanism underlying sweep-direction hysteresis and the corresponding model architecture. (a–d) Cross-sectional cavity schematics and (e–h) corresponding transmission plots at four stages of an increasing-wavelength sweep. The schematics show the optical mode, photocarriers, surface traps, and applied and space-charge fields; the plots distinguish the bare resonance, instantaneous resonance, and scan transmission up to each stage. Trap loading pulls the cavity resonance toward the scanning laser, compressing the trace. (i–l) Schematics and (m–p) transmission plots for a decreasing-wavelength sweep, in which the resonance is dragged away from the scanning laser, stretching the trace. (q) STPR model flow linking effective optical drive, photocarrier generation, voltage-biased trap loading, space charge, and the resonance shift. Blue outlines indicate the optical response, gray outlines the carrier dynamics, and gold outlines the transport feedback; block colors do not denote scan direction.

Cavity Response

The optical power inside the cavity drives carrier generation, so we first calculate how that power varies with laser detuning. The photon lifetime τph=Q/ω0≈40\tau_{\mathrm{ph}} = Q/\omega_0 \approx40 ps is more than ten orders of magnitude shorter than the approximately 1 s required to scan from the edge of the wavelength window to the cavity resonance at 2 nm s−1^{-1}, so the intracavity power follows the instantaneous detuning quasi-statically (adiabatic approximation). We express this dependence through the effective optical drive PeffP_{\mathrm{eff}}:

Peff=Pin[1+(Δtotγ)2]−1,(1)P_{\mathrm{eff}}=P_{\mathrm{in}}\left[1+\left(\frac{\Delta_{\mathrm{tot}}}{\gamma}\right)^2\right]^{-1}, \tag*{(1)}

We express detuning and linewidth in wavelength units. Over the narrow scan window, the frequency-domain Lorentzian is well approximated by this form, with wavelength half-width γ=λ0/(2Q)\gamma=\lambda_0/(2Q). The total detuning

Δtot=λscan−λ0−rVVapp+rVVscΔs(2)\Delta_{\mathrm{tot}}=\lambda_{\mathrm{scan}}-\lambda_0-r_VV_{\mathrm{app}}+r_VV_{\mathrm{sc}}\Delta s \tag*{(2)}

combines the laser’s detuning from the bare resonance λ0+rVVapp\lambda_0+r_VV_{\mathrm{app}}, including the electro-optic (Pockels) shift from the applied bias, and the screening term rVVscΔsr_VV_{\mathrm{sc}}\Delta s from the field associated with the trap occupancy imbalance Δs\Delta s via the resonance-shift coefficient VscV_{\mathrm{sc}}. The bare resonance, λ0+rVVapp\lambda_0+r_VV_{\mathrm{app}}, includes the electro-optic shift from the applied bias but excludes the photorefractive shift from trapped charge (Vsc=0V_{\mathrm{sc}}=0). Its zero-bias value is λ0\lambda_0. Here PinP_{\mathrm{in}} is the estimated optical power delivered to the cavity arm. (1) uses a unit-peak Lorentzian, so PeffP_{\mathrm{eff}} is an effective optical drive rather than the absolute circulating power; the fixed resonant build-up factor is absorbed into the fitted generation coefficient g0g_0.

The half-linewidth γ=λ0/(2Q)\gamma=\lambda_0/(2Q) is fixed by the loaded quality factor extracted from low-power spectra. We determine QQ by fitting the three output spectra simultaneously with Fano lineshapes, which account for interference between the cavity response and light from the other arms. For each low-power laser sweep, the three output spectra are fitted with a common resonance wavelength and linewidth, while allowing separate background and lineshape coefficients for each output. For each cavity, we use the median quality factor extracted from the low-power scans at 2 and 5 nm s−1^{-1} to set the model linewidth.

These fits use the measured transmission spectra after the output MMI. The Lorentzian in (1) describes the effective optical drive; the output transmission is calculated using the full 3×33\times3 interferometer model.

Carrier Partition: Langevin Function from First-Passage Theory

Following the photoexcited-carrier migration and trapping picture of [14], we treat the transported excitation as an effective mobile charged species without assigning a specific electronic or ionic identity. The mobile species perform a biased random walk in the transverse direction. We define VeffV_{\mathrm{eff}} as the signed carrier-drift voltage, positive for drift toward the right (+) sidewall. The mapping between the applied field and VeffV_{\mathrm{eff}} depends on the charge sign and microscopic transport mechanism and is absorbed into this signed definition. The probability u(ξ)u(\xi) that a single carrier generated at normalized transverse position ξ∈[0,1]\xi\in[0,1] becomes trapped at the right (+, ξ=1\xi=1) sidewall rather than the left (−, ξ=0\xi=0) sidewall is the first-passage probability satisfying the backward Kolmogorov equation [22]:

d2udξ2+Pedudξ=0,u(0)=0,u(1)=1,Pe=VeffVtr,(3)\frac{d^2u}{d\xi^2}+\mathrm{Pe}\frac{du}{d\xi}=0,\qquad u(0)=0,\quad u(1)=1,\quad\mathrm{Pe}=\frac{V_{\mathrm{eff}}}{V_{\mathrm{tr}}}, \tag*{(3)}

Here Pe\mathrm{Pe} is the carrier Péclet number, the dimensionless ratio of drift to diffusive transport across the waveguide. For ∣Pe∣≪1\lvert\mathrm{Pe}\rvert\ll1, diffusion produces nearly symmetric sidewall trapping; for ∣Pe∣≫1\lvert\mathrm{Pe}\rvert\gg1, drift dominates and the sign of Pe\mathrm{Pe} selects the favored sidewall. We parameterize this ratio by the effective transport-voltage scale VtrV_{\mathrm{tr}}, such that Pe=Veff/Vtr\mathrm{Pe}=V_{\mathrm{eff}}/V_{\mathrm{tr}}. For conventional nondegenerate transport, the Einstein relation gives D/μ=kBT/∣q∣D/\mu=k_{\mathrm{B}}T/\lvert q\rvert, where DD is the diffusion coefficient, μ\mu the carrier mobility, kBk_{\mathrm{B}} Boltzmann’s constant, TT the temperature, and qq the carrier charge. Here, however, VtrV_{\mathrm{tr}} is fitted phenomenologically and may incorporate non-Einstein hopping or trapping dynamics, field geometry, and the conversion between applied voltage and the microscopic transverse field; it is not interpreted as the lattice thermal voltage. The probability of reaching the right sidewall from position ξ\xi is u(ξ)=(1−e−Peξ)/(1−e−Pe)u(\xi)=(1-e^{-\mathrm{Pe}\xi})/(1-e^{-\mathrm{Pe}}).

We assume that carriers are generated uniformly across the waveguide, so every starting position contributes equally. The probability u(ξ)u(\xi) gives the chance that a carrier generated at position ξ\xi reaches the right sidewall. Averaging u(ξ)u(\xi) across the waveguide therefore gives the fraction p+p_+ of all generated carriers reaching that wall:

p+=∫01u(ξ) dξ.p_+=\int_0^1u(\xi)\,d\xi.

In this model, every carrier eventually reaches one of the two sidewalls, so the fraction reaching the left wall is p−=1−p+p_-=1-p_+. Their difference, δ=p+−p−\delta=p_+-p_-, measures the preference for trapping at one sidewall over the other. Substituting the expression for u(ξ)u(\xi) gives

δ=p+−p−=coth⁡(Veff2Vtr)−2VtrVeff≡L(Veff2Vtr),(4)\delta=p_+-p_-=\coth\left(\frac{V_{\mathrm{eff}}}{2V_{\mathrm{tr}}}\right)-\frac{2V_{\mathrm{tr}}}{V_{\mathrm{eff}}}\equiv L\left(\frac{V_{\mathrm{eff}}}{2V_{\mathrm{tr}}}\right), \tag*{(4)}

where L(ξ)=coth⁡ξ−1/ξL(\xi)=\coth\xi- 1/\xi is the Langevin function. Fitting C1C_1 alone, using all five powers and the three original scan speeds, gives Vtr=0.011V_{\rm tr}=0.011 V (Supplementary Table S1). The partition is controlled by the effective voltage, including transport feedback, rather than by the applied voltage alone. The sensitivity to centered optical-mode-like generation profiles is reported in Supplementary Table S8.

Trap Kinetics

The right (+) and left (−) sidewall trap occupancy fractions s+(t),s−(t)∈[0,1]s_+(t),s_-(t)\in[0,1] evolve by Shockley–Read–Hall kinetics [23]:

s˙+=g0Peff 12(1+δ)(1−s+)−krels+,(5)\dot{s}_+ = g_0P_{\rm eff}\,\frac{1}{2}(1+\delta)(1-s_+) - k_{\rm rel}s_+, \tag*{(5)}
s˙−=g0Peff 12(1−δ)(1−s−)−krels−,(6)\dot{s}_- = g_0P_{\rm eff}\,\frac{1}{2}(1-\delta)(1-s_-) - k_{\rm rel}s_-, \tag*{(6)}

where the effective photogeneration rate G=g0PeffG=g_0P_{\rm eff} is proportional to the effective optical drive, with coefficient g0g_0 in mW−1s−1\mathrm{mW}^{-1}\mathrm{s}^{-1}. The vacant-trap factor (1−s±)(1-s_\pm) limits further capture as the traps fill. We assume that the trap-release rate krelk_{\rm rel} follows an Arrhenius law krel=k0e−Ea/kBTk_{\rm rel}=k_0e^{-E_a/k_BT}, where k0k_0 is the release-rate prefactor, EaE_a is the trap-release activation energy, kBk_B is the Boltzmann constant, and TT is the absolute temperature. The trap occupancy imbalance Δs=s+−s−\Delta s=s_+-s_- determines the space-charge field in the model. The weak measured dependence on scan speed motivates a quasi-static approximation. Away from switching points, we assume that the trap populations relax to local steady state faster than the laser detuning changes appreciably. Setting s˙±=0\dot{s}_\pm=0 in Eqs. (5) and (6) gives

s±ss=ap±1+ap±,a=RPeff,R=g0krel.(7)s_\pm^{\rm ss}=\frac{a p_\pm}{1+a p_\pm},\qquad a=RP_{\rm eff},\qquad R=\frac{g_0}{k_{\rm rel}}. \tag*{(7)}

Here RR has units of mW−1\mathrm{mW}^{-1}, and a=G/krela=G/k_{\rm rel} is the dimensionless ratio of the effective photogeneration rate to the trap-release rate. The loading-to-release ratio for each sidewall is ap±a p_\pm. Each occupancy grows linearly for ap±≪1a p_\pm\ll1 and approaches one for ap±≫1a p_\pm\gg1. The scale 1/R1/R is the effective optical drive at which the generation rate GG equals the release rate krelk_{\rm rel}. Each sidewall reaches half occupancy when RPeffp±=1R P_{\rm eff}p_\pm=1. We assume that the two sidewalls can hold equal amounts of trapped charge when fully occupied. The charge imbalance is then proportional to s+−s−s_+-s_-. As both sides approach full occupancy, this imbalance and its contribution to the resonance shift approach zero. Filling the traps therefore does not necessarily make the hysteresis gap approach a constant value.

Voltage Enhancement and Space-Charge Feedback

The applied external voltage is included in the model through an effective drift voltage

Veff=Vapp+Vpv0+Vfb Δs,(8)V_{\rm eff}=V_{\rm app}+V_{\rm pv0}+V_{\rm fb}\,\Delta s, \tag*{(8)}

where Vpv0V_{\rm pv0} is the built-in photovoltaic offset and VfbV_{\rm fb} is the transport-feedback coefficient. The fitted built-in photovoltaic offset may contain a contribution from the bulk photovoltaic effect, but the resonance scans alone do not isolate its microscopic origin. As ∣Veff∣\lvert V_{\rm eff}\rvert increases, drift becomes stronger relative to diffusion, and the two sidewalls receive increasingly unequal fractions of the photogenerated carriers.

The space-charge field has two effects: it shifts the cavity resonance through the Pockels effect and modifies the drift of subsequently generated carriers. The first effect is a resonance shift through the Pockels effect. We define the screening term εscr\varepsilon_{\rm scr} by

εscr=rVVsc Δs,(9)\varepsilon_{\rm scr}=r_V V_{\rm sc}\,\Delta s, \tag*{(9)}

The corresponding PR-induced resonance-wavelength shift relative to the electro-optic position is ΔλPR=−εscr\Delta\lambda_{\rm PR}=-\varepsilon_{\rm scr}. Here Vsc∝∫r33(x)Esc(x)∣E(x)∣2 dxV_{\rm sc}\propto\int r_{33}(x)E_{\rm sc}(x)\lvert\mathcal{E}(x)\rvert^2\,dx encodes the spatial overlap of the dominant Pockels tensor element r33(x)r_{33}(x), the space-charge field profile Esc(x)E_{\rm sc}(x) (Δs=1\Delta s=1), and the optical mode intensity ∣E(x)∣2\lvert\mathcal{E}(x)\rvert^2; since ∣Δs∣≤1\lvert\Delta s\rvert\leq1, VscV_{\rm sc} is the resonance-shift voltage at maximum trap imbalance, ∣Δs∣=1\lvert\Delta s\rvert=1. The second effect is feedback on carrier transport. The VfbΔsV_{\rm fb}\Delta s term in Eq. (8) modifies the drift of subsequently generated carriers. We restrict Vfb≤0V_{\rm fb}\leq0 to represent opposing space-charge feedback. For Vfb<0V_{\rm fb}<0, increasing Δs\Delta s reduces VeffV_{\rm eff} and the carrier-partition asymmetry, thereby suppressing further asymmetric trap loading.

Quasi-Static Reduction and Branch Selection

To predict the resonance along a laser scan, we solve for the steady-state trap imbalance and effective optical drive together. Subtracting the two steady-state occupancies gives

Δs=aδ(Δs)1+a+14a2[1−δ(Δs)2],a=RPeff(λscan,Δs),(10)\Delta s = \frac{a\delta(\Delta s)}{1+a+\frac{1}{4}a^2[1-\delta(\Delta s)^2]}, \qquad a=RP_{\mathrm{eff}}(\lambda_{\mathrm{scan}},\Delta s), \tag*{(10)}

with δ(Δs)=L[(Vapp+Vpv0+VfbΔs)/(2Vtr)]\delta(\Delta s)=L[(V_{\mathrm{app}}+V_{\mathrm{pv0}}+V_{\mathrm{fb}}\Delta s)/(2V_{\mathrm{tr}})] and the effective optical drive given by Eq. (1). At fixed effective optical drive, negative transport feedback gives a unique stable steady state (Supplementary Note 6.2). In the cavity, however, trapped charge shifts the resonance and thereby changes the optical drive. This feedback can support two stable steady-state solutions at the same laser wavelength. As the laser wavelength changes, the cavity remains near its current equilibrium as long as small disturbances to the trap populations decay. If that equilibrium becomes unstable, the trap populations evolve toward another stable state. We use the trap-rate equations, Eqs. (5) and (6), to determine which state is reached. Figure 3 illustrates the resulting hysteresis and how it develops with increasing input power: the scan paths coincide in panel (a), whereas panels (b,c) show hysteresis. In the steady-state model, the two rates enter only through their ratio R=g0/krelR=g_0/k_{\mathrm{rel}}. The fits therefore cannot determine g0g_0 and krelk_{\mathrm{rel}} separately.

Figure 3. Quasi-static hysteresis from stable-branch selection. Normalized effective optical drive Peff/PinP_{\mathrm{eff}}/P_{\mathrm{in}} versus laser detuning from the bare resonance for the independent C3C_3 fit (Supplementary Table S1) at Vapp=+30V_{\mathrm{app}}=+30 V and estimated cavity-arm input powers (a) −26.8, (b) −16.8, and (c) −11.8 dBm, using identical axis ranges. Solid blue and yellow curves follow stable states for increasing and decreasing wavelength, respectively. Where the paths coincide, blue and yellow alternate along one continuous curve. Arrows indicate scan directions and jumps between stable states. Gray dashed curves show unstable equilibria according to the full two-occupancy Jacobian including cavity feedback. Shaded intervals contain two stable equilibria, and open circles mark the switching points. The vertical gray line marks zero detuning from the bare resonance. The scan paths coincide in (a), while (b,c) exhibit hysteresis. In (c), the two switches occur at detunings −86.1 and −189.1 pm, respectively. The plot illustrates the fitted model, not an additional measurement; no scan-speed magnitude enters the quasi-static calculation.

Numerical Implementation and Fitting

For each measured voltage and input power, we solve Eq. (10) over the experimental wavelength window. The model can have two stable steady-state solutions at a given wavelength. We initialize each modeled scan on the stable branch connected to the far-from-resonance state, assuming that the trap populations have relaxed before the scan begins. As the wavelength changes, we follow the connected sequence of stable solutions, called a branch.

A steady state is stable if a small change in the trap populations is followed by a return to their equilibrium values. We call the wavelength at which the followed branch loses stability a switching point. For example, during the decreasing-wavelength scan shown in yellow in Figure 3(b,Figure 3c), the system follows the upper stable branch toward the peak in optical power. Beyond this turning point, at shorter laser wavelengths, only the lower stable branch remains available, so the system switches abruptly to it. We use the trap-rate equations, Eqs. (5) and (6), to calculate how the populations evolve during this jump, holding the wavelength just beyond the switching point. Once they reach the new equilibrium, we continue to model the scan. Opposite scan directions can therefore follow different branches and switch at different wavelengths. The stability test and numerical checks are detailed in Supplementary Note 1.2.

We calculate the detector transmission from these solutions using the three-arm interferometer model described in Supplementary Note 7. Switching between stable states produces a sharp feature in the detected transmission. Its rising edge provides an experimentally accessible marker of the transition and lies close to the calculated switching wavelength for the conditions in Figure 3(b,Figure 3c). We extract this marker from both measured and simulated transmission using the same procedure (Supplementary Note 4), and use its separation between opposite scan directions to quantify the hysteresis gap.

For each acquisition, we fit the device’s optical response to the lowest-power transmission spectra. The eight fitted coefficients describe the cavity response and the relative amplitudes and phases of light returning through the three interferometer arms (Supplementary Note 7). We then hold these coefficients fixed while fitting the resonance positions.

We fit each cavity independently using all five input powers, all retained voltage settings, and all three scan speeds in the three-cavity dataset. For each cavity, a single set of physical parameters describes all powers and scan speeds. The bare electro-optic tuning coefficient rVr_V is also common to these measurements, while the reference wavelength λ0\lambda_0 is fitted separately for each scan-speed run to accommodate resonance shifts between acquisitions, likely caused by temperature drift [24].

Even at the two lowest input powers, trapped charges shift the cavity resonance. A linear fit to these scans would therefore mix the bare electro-optic tuning with photorefractive shifts. We determine rVr_V and λ0\lambda_0 together with the physical parameters using the full dataset (Supplementary Note 1).

We fit the model by minimizing a cost function based on the mean squared differences between measured and calculated resonance wavelengths for both laser scan directions. The fitted parameters and fixed inputs are listed in Table 1. We calculate the hysteresis gap from the fitted wavelengths and compare them with the measurements. We use the same cost function for the independent fits, shared-parameter fits, and model comparisons. Supplementary Note 1.2 defines the cost function.

SymbolMeaningUnitsTreatment in the fit
R=g0/krelR = g_0/k_{\mathrm{rel}}Trap loading-to-release ratiomW−1\mathrm{mW}^{-1}Fitted (per cavity)
VtrV_{\mathrm{tr}}Carrier-transport voltage scaleVFitted (per cavity)
VscV_{\mathrm{sc}}Resonance-shift coefficientVFitted (per cavity)
VfbV_{\mathrm{fb}}Transport-feedback coefficientVFitted (per cavity)
Vpv0V_{\mathrm{pv0}}Effective photovoltaic offsetVFitted (per cavity)
rVr_VBare electro-optic tuning coefficientpm V−1\mathrm{pm}\ \mathrm{V}^{-1}Fitted (per cavity)
λ0\lambda_0Zero-bias reference wavelengthnmFitted (per scan-speed dataset)
QQLoaded quality factor—Fixed
PinP_{\mathrm{in}}Estimated cavity-arm input powermWFixed

Table 1. Parameters and inputs for the independent cavity fits. All quantities marked “fitted” are optimized together using the measured resonance positions. Each cavity has one set of parameters shared across powers and scan speeds, except for λ0\lambda_0, which is fitted separately for each scan-speed dataset. The loaded quality factor is measured and the cavity-arm input powers are estimated; both are held fixed. The interferometer coefficients are fitted separately to low-power transmission spectra and held fixed during the resonance-position fits.

To check numerical reliability, we test the sensitivity of the fits to starting values and numerical resolution (Supplementary Note 1.2). To assess parameter robustness, we repeat the fits on resampled datasets (Supplementary Note 5.3).

Results

Independent and Joint Fits

Figure 4(a–Figure 4c) shows the measured resonance wavelength of cavity C1C_1 as the applied voltage is stepped from −30 to +30 V. At each voltage, separate increasing- and decreasing-wavelength sweeps at 2 nm s−1^{-1} provide the two resonance positions for each of three estimated cavity-arm input powers. At every power, the resonance shifts with applied voltage, while a direction-dependent separation is observed between the up- and down-sweep traces. This separation increases monotonically with estimated cavity-arm input power across the three measurements.

Figure 4. Measured and modeled resonance tuning of cavity C1. Resonance wavelength across the stepped applied-voltage sweep at 2 nm s−1^{-1} for estimated cavity-arm input powers of (a) −16.8 dBm, (b) −11.8 dBm, and (c) −6.8 dBm. Blue and gold symbols mark the measured cavity-resonance positions during increasing- and decreasing-wavelength sweeps, respectively; lines show positions extracted from modeled transmission using the same rising-edge procedure (RMS residuals 18.7, 15.7, and 18.7 pm). The fit includes all five powers and all three scan speeds with the numerical scan protocol of Sec. 4.

The STPR model successfully reproduces the overall voltage dependence and the increase in sweep-direction separation with power, but underestimates the continued growth of the hysteresis gap at the highest measured power. Across the three cavities, the root-mean-square (RMS) difference between modeled and measured resonance wavelengths is 13.2–17.7 pm at 2 nm s−1^{-1} and 13.9–17.3 pm over all three scan speeds, evaluated over the three higher input powers (−16.8 to −6.8 dBm).

Independent fits to the three cavities give R=22.5R=22.5–39.0 mW−1^{-1}, Vtr=0.011V_{\mathrm{tr}}=0.011–0.170 V, and Vfb/Vsc=−1.50V_{\mathrm{fb}}/V_{\mathrm{sc}}=-1.50 to −1.45. Supplementary Table S1 reports the complete parameter sets.

To quantify the effect of sharing parameters, we fit the three cavities jointly with common RR and VtrV_{\mathrm{tr}}, while allowing VscV_{\mathrm{sc}}, VfbV_{\mathrm{fb}}, VpvoV_{\mathrm{pvo}}, rVr_V, and λ0\lambda_0 to remain cavity-specific. Sharing those two parameters reduces the physical parameter count from 15 to 11, or from 27 to 23 including rVr_V and the wavelength offsets. The separately fitted interferometer coefficients are fixed in both comparisons (Table 1). Both use the wavelength cost function defined in Supplementary Note 1.2, with equal weight for each cavity and input power.

The joint fit gives an upper-power position RMS of 15.42 pm over 283 positions at 2 nm s−1^{-1} and 15.73 pm over all three speeds. Sharing RR and VtrV_{\mathrm{tr}} increases the cost function value by 1.4% relative to fitting them independently for each cavity. A common pair therefore describes these measurements nearly as well as separate values. Supplementary Table S2 and Supplementary Fig. S1 give the parameters and curves. Supplementary Fig. S2 shows the independent fit and measured branches for cavity C3C_3.

Full-Spectrum Comparison

Figure 5 compares the measured (a) and modeled (b) transmission spectra of C3C_3, testing whether the parameters fitted to resonance positions also reproduce the spectral shapes. We calculate the transmission using the steady-state cavity response and a three-arm interferometer model that accounts for interference between the cavity and two reference arms. The interferometer coefficients are fixed across all voltages and both scan directions.

Figure 5. Measured and modeled spectra of cavity C3 at 2 nm s−1^{-1} and a +1 dBm source setting (estimated cavity-arm input power −11.8-11.8 dBm). (a) Experiment and (b) steady-state STPR model with an effective 3×33 \times3 readout. Color progresses from blue to gold as the applied voltage increases from −30-30 to +30+30 V in 4 V steps; solid and dashed curves denote increasing- and decreasing-wavelength sweeps. The four traces at each voltage share one vertical normalization and offset. Background processing and optical calibration are detailed in Supplementary Note 7.

The calculated spectra reproduce the main changes in line shape with applied voltage, with an overall normalized RMS spectral error of 10.3%. The interferometer model and error calculation are described in Supplementary Note 7.

Scan-Speed Dependence

We repeated the power- and voltage-dependent measurements on cavity C1C_1 at four additional scan speeds (1, 10, 50, and 200 nm s−1\mathrm{nm}\ \mathrm{s}^{-1}). We jointly fit the C1C_1 measurements from the three-cavity and scan-speed datasets, covering all seven scan speeds and five powers, using a common set of physical parameters. For each sweep direction, the model follows a stable branch and switches when that branch loses stability; scan speed does not enter the calculation. The shared parameters are RR, VtrV_{\mathrm{tr}}, VscV_{\mathrm{sc}}, VfbV_{\mathrm{fb}}, and Vpv0V_{\mathrm{pv0}}. A single bare electro-optic tuning coefficient rVr_V is shared across all seven speeds; only the resonance offset λ0\lambda_0 is fitted separately for each measurement run. Supplementary Fig. S3 compares the fit with measurements at the four additional speeds; the acquisition details and fit parameters are given in Supplementary Note 3.1.

Across all four additional scan speeds, the measured hysteresis gap retains a similar voltage dependence and does not collapse at the fastest scan. At +24 V and an estimated cavity-arm input power of −11.8 dBm, the measured gap is 81, 81, 86, and 88 pm at 1, 10, 50, and 200 nm s−1\mathrm{nm}\ \mathrm{s}^{-1}, respectively. The shared fit follows the measured branches and their voltage-dependent separation, with a pooled position RMS of 16.7 pm over the 234 retained positions at the three upper powers and four additional speeds.

Keeping the physical parameters from the three-cavity dataset fixed gives a pooled RMS position error of 18.9 pm for the higher-power scans at the additional speeds, compared with 16.7 pm obtained from the joint fit. This supports the applicability of the quasi-static model across the measured scan-speed range of 1–200 nm s−1\mathrm{nm}\ \mathrm{s}^{-1}, with the same physical parameters describing the hysteretic response of C1C_1 throughout this range. The test procedure is detailed in Supplementary Note 5.4.

Discussion and Conclusion

In the STPR model, applied bias changes the distribution of photoexcited carriers between the sidewall traps. Unequal accumulation of these carriers at the two sidewalls creates a space-charge field that shifts the cavity resonance through the electro-optic effect. At fixed optical power, negative transport feedback gives the trap populations a unique, locally stable steady state (Supplementary Note 6.2). In the cavity, trap loading changes the detuning and therefore the optical power driving further loading. This feedback can support two stable steady states at the same laser wavelength.

The laser scan direction determines which stable branch the system follows. Increasing- and decreasing-wavelength scans can therefore switch between states at different wavelengths, producing hysteresis in the measured resonance position. The modest change in this wavelength separation over a 200-fold range in laser scan speed supports the quasi-static description used here.

Surface and dielectric-interface traps provide a physical basis for the voltage-dependent carrier redistribution in the model. Previous measurements in TFLN microrings showed a strong influence of dielectric cladding on photorefraction, including suppression after cladding removal and re-annealing [14]. A closely related air-clad TFLN PhCC IQ modulator exhibits approximately linear voltage tuning without the pronounced voltage-enhanced hysteresis observed here, despite slower PR-related transmission drift [10]. Together with the suppression of surface-state-driven carrier noise by post-fabrication annealing [15], these observations support a contribution from surface and interface traps. In the STPR model, the applied field redistributes photoexcited carriers between the traps through Eqs. (8) and (4). At zero applied bias, the fitted photovoltaic offset can still bias the carrier partition. The offset is an effective fit parameter, so its value alone cannot identify a microscopic photovoltaic field.

The fitted ratio Vfb/VscV_{\mathrm{fb}}/V_{\mathrm{sc}} compares the transport-feedback coefficient VfbV_{\mathrm{fb}} with the resonance-shift coefficient VscV_{\mathrm{sc}}. The two coefficients weight the space-charge field differently, according to optical mode intensity for VscV_{\mathrm{sc}} and carrier density for VfbV_{\mathrm{fb}}. Their ratio is therefore not fixed by the model. The fitted coefficients vary across cavities, with Vfb/VscV_{\mathrm{fb}}/V_{\mathrm{sc}} ranging from −1.50 to −1.45 in the independent fits. Compensation between these coefficients limits their microscopic interpretation. Negative VfbV_{\mathrm{fb}} suppresses further asymmetric trap loading as charge accumulates. The extent to which this feedback opposes the applied voltage depends on VfbV_{\mathrm{fb}} and the trap imbalance.

Trap filling and transport feedback set the power and voltage scales of the modeled hysteresis. At large ∣Veff∣/Vtr\lvert V_{\mathrm{eff}}\rvert/V_{\mathrm{tr}}, the partition asymmetry approaches unity as ∣δ∣≃1−2Vtr/∣Veff∣\lvert\delta\rvert\simeq1-2V_{\mathrm{tr}}/\lvert V_{\mathrm{eff}}\rvert. The resulting trap imbalance also depends on power and feedback. The characteristic power 1/R≈261/R \approx26–45 μW45\,\mu\mathrm{W} describes the effective intracavity drive at which loading competes with release. The measurements have not established a saturation power. At sufficiently high optical power, the model predicts that traps at both sidewalls would approach full occupancy, reducing their occupancy difference and the resulting photorefractive resonance shift.

The modeled gap flattens at high voltage, whereas the measured gap continues to grow approximately linearly with ∣Vapp∣\lvert V_{\mathrm{app}}\rvert up to 30 V (Figure 4). The model consequently underestimates the gap at ∣Vapp∣≳20\lvert V_{\mathrm{app}}\rvert\gtrsim20 V, with larger discrepancies at higher optical power. Improving agreement through physically motivated extensions of the model is promising future work.

We assessed the variability of the fitted parameters and predicted resonance positions by repeating the fits on 512 artificial datasets with deviations from the model comparable in size to those observed experimentally. The predicted resonance positions changed by a median RMS of 3.0–3.5 pm across the four fits, while some fitted parameters varied more substantially. The procedure and resulting parameter ranges are described in Supplementary Note 5.3.

We also tested sensitivity to ambiguous resonance assignments and finite wavelength sampling. Excluding ambiguous positions changed the predicted curves by at most 1.6 pm RMS. The sampling test gave changes of about 1 pm; the procedure and its numerical limitations are described in the Supplementary Information (Supplementary Notes 5.2 and 5.3).

Xu et al. [14] reported pronounced scan-speed dependence in oxide-clad lithium-niobate microrings, with a characteristic response on the order of 10 ms. Differences in optical confinement, carrier transport, and interface traps may contribute to the weaker speed dependence observed here. Our steady-state fits constrain the loading-to-release ratio RR, but cannot determine the individual rates or identify which processes set the response time. Multiplying g0g_0 and krelk_{\mathrm{rel}} by the same factor leaves RR and the steady-state response unchanged. Time-resolved measurements are needed to determine the absolute trap rates and the duration of switching transients. They would also test whether the trap populations lag behind their local steady state during a laser scan.

Reducing the loading-to-release ratio RR offers a route to mitigating photorefractive shifts by raising the characteristic loading power. Passivating the etched sidewalls or modifying the cladding could reduce carrier trapping. In the Shockley–Read–Hall rate equations, either decreasing g0g_0 or increasing krelk_{\mathrm{rel}} reduces RR, although the steady-state fits cannot distinguish these routes. UV illumination has also been shown to accelerate the photorefractive response in TFLN microdisks [25], demonstrating that the overall response kinetics can be modified optically.

A promising application of our model would be to guide feed-forward voltage compensation by predicting how photorefraction changes the dependence of the resonance wavelength on applied voltage. Because the response is hysteretic, the correction would depend on which stable branch the cavity occupies. Computing stable operating points and selecting voltages within a known branch required only microseconds in our numerical tests (Supplementary Note 1.4). Time-resolved measurements would be needed to determine how rapidly this compensation could operate.

Voltage pulses could potentially switch the cavity between its coexisting stable states, allowing information to be stored in its optical response under continuous illumination. Our steady-state fits cannot determine how quickly these states could be written or how long they would persist after illumination is removed. A write–wait–read experiment would directly test these possibilities. Long-lived photorefractive and pyroelectric states reported in TFLN microresonators [26] motivate such an investigation.

We observed voltage-enhanced photorefractive hysteresis in three thin-film lithium niobate photonic-crystal cavities, studied its dependence on applied voltage, optical power, and laser scan speed, and developed a quasi-static surface-trap model to explain the measured behavior. The model captures the observed switching between stable steady states and reproduces the main trends in voltage- and power-dependent hysteresis. At estimated cavity-arm input powers of −16.8, −11.8, and −6.8 dBm, the hysteresis gap reaches about 50–150 pm near ∣V∣=30|V| = 30 V. The weak dependence on scan speed over 1–200 nm s−1^{-1} supports the quasi-static description.

The steady-state model could guide resonance calibration by accounting for scan history. The model also provides a quantitative tool for investigating the reduction of trap loading towards mitigation of photorefractive shifts.

Funding

This work was supported by the DEVCOM Army Research Laboratory under Cooperative Agreement No. W911NF-22-2-0127. A.B. acknowledges support from the Air Force Research Laboratory under Award No. FA8750-25-2-0500 and from the Defense Advanced Research Projects Agency (DARPA) through the NanoWatt Platforms for Sensing, Analysis and Computation (NaPSAC) program as part of the TOPCHIP project under subcontract No. SCON-00005835. M.H. acknowledges support from The Novo Nordisk Foundation (REPEAT, grant no. NNF24OC0096351).

Acknowledgments

The authors thank Steven Nagle and the T. J. Rodgers RLE Laboratory for their continued support in developing the experimental setup. The authors thank CSEM, in particular Homa Zarebidaki, Amir H. Ghadimi, and Hamed Sattari, for fabricating the chips.

Generative AI tools assisted with portions of code development, data analysis, mathematical analysis, and manuscript review. The authors reviewed and validated the AI-assisted work. They retain full responsibility for the scientific content, results, and conclusions.

Disclosures

The authors declare no conflicts of interest.

Code and Data Availability

The experimental spectra and extracted resonance positions are on Zenodo (https://doi.org/10.5281/zenodo.24206999). The resonance-tracking and model-fitting code, fitted parameters, and conditional robustness analyses are available on GitHub (https://github.com/sandrobuzzi/Voltage-Enhanced-Photorefraction). See Supplement 1 for supporting content.

Supplementary Note 1: Fitting Procedure and Numerical Methods

We describe the measurement sequence, simulated scan protocol, and fitting procedure used to relate the measured resonance positions to the STPR parameters.

Acquisition and Simulated Scan Sequence

For the 2, 5, and 20 nm s−1^{-1} measurements, the laser scans 1540–1543 nm in the decreasing-wavelength direction before the increasing-wavelength direction at each bias setting. The voltage program runs from −30 to +30 V and back in 4 V steps, while the saved archive contains one pair of scans at each of the 16 distinct voltages. The independent 1, 10, 50, and 200 nm s−1^{-1} measurements scan 1541–1542 nm in the increasing-wavelength direction before the decreasing-wavelength direction at each bias setting. Both acquisition routines return the laser to 1550 nm between individual scans; sweep-completion waits and laser positioning leave a seconds-long interval between the paired sweeps. The quasi-static calculation uses the recorded wavelength windows and sweep directions. We assume that, before each scan begins, the trap populations have relaxed to their stable equilibrium far from resonance. Returning the laser to 1550 nm places it far from the cavity resonances, reducing cavity-enhanced excitation during the seconds-long interval between scans and allowing trapped carriers to relax. The model does not infer a dark relaxation time or simulate optical excitation during the laser return.

Steady-State Solver and Fitting Cost Function

For each input power, we calculate the mean squared difference between measured and modeled resonance wavelengths over all retained voltage settings, scan speeds, and scan directions. We then average these errors with equal weight for each power,

J(θ)=1NP∑p=1NP1Nλ,p∑i=1Nλ,p[λsim,pi(θ)−λobs,pi]2,(11)\mathcal{J}(\theta) = \frac{1}{N_{P}} \sum_{p=1}^{N_{P}} \frac{1}{N_{\lambda,p}} \sum_{i=1}^{N_{\lambda,p}} [\lambda_{\mathrm{sim},pi}(\theta) - \lambda_{\mathrm{obs},pi}]^{2}, \tag*{(11)}

Here θ\theta denotes the set of parameters being fitted, and λsim,pi\lambda_{\mathrm{sim},pi} and λobs,pi\lambda_{\mathrm{obs},pi} are the modeled and measured resonance wavelengths for observation ii at input-power setting pp. NPN_{P} counts the input powers, and Nλ,pN_{\lambda,p} counts the retained observations at each power. Wavelength differences are expressed in picometers. All retained points within a power have equal weight; powers with more retained points therefore do not dominate the fit. The independent cavity and seven-speed fits use all five powers. The shared-cavity fit averages this cost function equally across the three cavities. Model comparisons use the same cost function and retained data. The hysteresis gap measures the separation between the sharp transmission transitions in the two laser scan directions. We determine it from the extracted resonance wavelengths after fitting; it does not enter the cost function separately.

To test the model against the scan-speed dataset, we hold RR, VtrV_{\mathrm{tr}}, VscV_{\mathrm{sc}}, VfbV_{\mathrm{fb}}, and Vpv0V_{\mathrm{pv0}} fixed at their values fitted to C1C_1 in the three-cavity dataset. Using only the two lowest input powers of the scan-speed dataset, we fit one common electro-optic tuning coefficient rVr_V and a separate reference wavelength λ0\lambda_0 for each acquisition. The three-arm interferometer coefficients remain fixed. We evaluate the three higher powers without further fitting.

We solve the steady-state equation, Eq. (10), numerically. We determine stability from the Jacobian of the trap-rate equations, Eqs. (5) and (6). This 2×22 \times2 matrix contains the derivatives of the two trapping rates with respect to the two trap populations, including the dependence of cavity power on trapped charge. A steady state is stable when both eigenvalues have negative real parts, so small disturbances decay. We locate switching points where the followed steady state loses stability. For each of the three independent cavity fits and the seven-speed C1C_1 fit, we run the optimization from different starting sets of parameter values. We compare the resulting fits and retain the solution with the smallest cost function value. Fourteen starting sets per fit are optimized, followed by six additional local starts, refinement on a finer grid, and a derivative-free local search. Every accepted solution must produce all required resonance wavelengths along complete stable scan paths. These checks reduce dependence on the starting values but do not guarantee that we have found the global minimum.

For the fit tables, we also report the mean squared wavelength error over the specified subset of measurements

MSE⁡subset(θ)=1N∑p,w,dir,i[λsim(Vi;θ)−λobs(Vi)]2×106 [pm2],(12)\operatorname{MSE}_{\mathrm{subset}}(\theta)=\frac{1}{N}\sum_{p,w,\mathrm{dir},i}\left[\lambda_{\mathrm{sim}}(V_i;\theta)-\lambda_{\mathrm{obs}}(V_i)\right]^2 \times10^6\ [\mathrm{pm}^2], \tag*{(12)}

Here NN is the number of included measurements, and the wavelength differences are expressed in nanometers; the factor 10610^6 converts the squared differences to pm2\mathrm{pm}^2. The error is evaluated over the points stated in each table (the 16 voltage steps, the three upper power levels, and two sweep directions for the 2 nm s−1\mathrm{nm}\,\mathrm{s}^{-1} summaries). Unlike the fitting cost function, this descriptive error pools the stated points without equalizing the powers. The parameters RR and VtrV_{\mathrm{tr}} are log-parameterized to enforce positivity and improve conditioning.

For numerical stability, the Langenvin function is evaluated via its Taylor expansion for small arguments (∣ξ∣<10−2|\xi| < 10^{-2}), avoiding catastrophic cancellation in both ξ−1/ξ\xi- 1/\xi.

For every parameter set tested during fitting, we simulate each wavelength scan by following stable steady states, for which both eigenvalues of the Jacobian have negative real parts. After a loss of stability, the trap populations must settle into a definite stable equilibrium before the scan continues. Parameter sets are excluded if this transition cannot be determined or if any required modeled resonance position is missing. For the three independent cavity fits and the seven-speed fit, an independent calculation checks 700 complete scan paths across all five powers, including the original 2 nm s−1\mathrm{nm}\,\mathrm{s}^{-1} and additional 1 and 200 nm s−1\mathrm{nm}\,\mathrm{s}^{-1} scans. Fixed-wavelength integration of the SRH equations verifies 141 jumps, including every loss of stability to oscillatory disturbances (Hopf bifurcation) in those paths and representative switching points where stable and unstable branches meet and terminate (folds). In every checked transition, the populations relax to the selected stable equilibrium. The independent calculation and refinement of the 801-point geometry grid to 1601 points change the selected transmission markers by less than 0.009 pm, indicating the 801-point grid has sufficient resolution. All 440 additional-acquisition scan starts have a unique attracting state at the recorded wavelength-window endpoint for the selected seven-speed fit. Absolute rate scaling supplies only an arbitrary time unit in the jump checks; it does not determine a physical switching time.

Photorefractive Curvature in the Low-Power Calibration

Calibrating the bare electro-optic tuning coefficient rVr_V and resonance offset λ0\lambda_0 by a linear regression on the lowest-power series (estimated cavity-arm input powers of −26.8-26.8 and −21.8-21.8 dBm) assumes negligible photorefractive curvature. The steady-state model retains a photorefractive shift at these powers, and the extracted positions can still differ between sweep directions.

Residual photorefraction can therefore bias the linear calibration. For this reason rVr_V and λ0\lambda_0 are fitted jointly with the STPR parameters through the model itself, using all five powers, in both the independent cavity fits and the shared seven-speed fit. The jointly fitted rVr_V is 15.6–15.7 pm V−1\mathrm{V}^{-1} for the independent C1C_1–C3C_3 fits and 15.36 pm V−1\mathrm{V}^{-1} for the shared seven-speed fit.

Computational Speed and Prospective Resonance Control

We measured how long the model takes to update the cavity resonance after a small change in laser wavelength. Using the fitted parameters of all three cavities at three input powers, each update on a known stable branch took approximately 1.3–1.4 μ\mus on an Apple M4 Pro. We also tested the reverse calculation: finding the applied voltage needed to reach a chosen cavity resonance while holding the laser wavelength and input power fixed. For a target on a known stable branch, this took approximately 18 μ\mus. These timings exclude initialization and measure computation time, not how quickly the physical cavity responds.

Fit Results and Model Comparison

We report the per-cavity and shared-cavity parameter sets, then compare how changes to the carrier partition and feedback affect the fits.

Fit Parameters

Supplementary Table S1. Quasi-static STPR parameters fitted to the three-cavity dataset, including all five input powers and scan speeds of 2, 5, and 20 nm s−1^{-1}. The jointly fitted rVrV values are 15.56, 15.68, 15.67 pm V−1^{-1} for C1C_1–C3C_3, with one resonance offset per speed. Fixed measured loaded quality factors are 5.4 × 104^4, 5.0 × 104^4, and 5.1 × 104^4. The mean squared wavelength error (MSE) uses the three upper powers at 2 nm s−1^{-1}. CV is the descriptive coefficient of variation across three point estimates, not parameter uncertainty. Ratios are calculated before rounding.

Ch.RR (mW−1^{-1})VtrV_{\rm tr} (V)VscV_{\rm sc} (V)VfbV_{\rm fb} (V)Vpv0V_{\rm pv0} (V)Vfb/VscV_{\rm fb}/V_{\rm sc}MSE (pm2^2)
C1C_139.010.011+19.18−28.76+0.411−1.499314.9
C2C_222.460.101+20.91−31.08+0.257−1.486246.9
C3C_322.880.170+20.68−29.93+0.350−1.447175.3
CV [%]348554———

Table S1.

Supplementary Table S2. Shared quasi-static fit using the same wavelength cost function as the independent fits. RR and VtrV_{\rm tr} are shared; resonance-shift, transport-feedback, and wavelength calibration parameters are cavity-specific. The fitted rVrV values are 15.28, 15.75, 15.67 pm V−1^{-1}, with one offset per cavity and speed. The optical readouts and measured QQ values are fixed. The reported mean squared wavelength error includes the three highest input powers and all three scan speeds (2, 5, and 20 nm s−1^{-1}).

ScopeParameterValueUnit
SharedRR24.71mW−1^{-1}
SharedVtrV_{\rm tr}0.100V
C1C_1VscV_{\rm sc}+23.05V
C1C_1VfbV_{\rm fb}−32.29V
C1C_1Vpv0V_{\rm pv0}+0.288V
C2C_2VscV_{\rm sc}+20.53V
C2C_2VfbV_{\rm fb}−30.38V
C2C_2Vpv0V_{\rm pv0}+0.454V
C3C_3VscV_{\rm sc}+19.48V
C3C_3VfbV_{\rm fb}−29.45V
C3C_3Vpv0V_{\rm pv0}+0.422V
AllMean squared wavelength error247.3pm2^2

Table S2.

Sensitivity of the fitted transport scale to its allowed range and to sharing parameters across cavities is examined in Supplementary Note 5.5. The fitted photovoltage offsets are effective parameters that can also absorb voltage calibration and model mismatch; they do not by themselves measure intrinsic photovoltage fields.

Figure S1. Shared quasi-static fit across the three cavities. Measured resonance positions (points) and predictions from the shared-parameter fit (lines) at 2 nm s−1^{-1} are shown for cavities C1_1–C3_3 (rows) and the three highest input powers (columns). Blue and gold denote increasing- and decreasing-wavelength sweeps, respectively. The fit shares RR and VtrV_{\mathrm{tr}} across all cavities while retaining cavity-specific VscV_{\mathrm{sc}}, VfbV_{\mathrm{fb}}, and Vpv0V_{\mathrm{pv0}}, and gives an overall RMS residual of 15.42 pm over the 283 displayed points at 2 nm s−1^{-1} (mean squared wavelength error 237.7 pm2^2).

Model Comparison

We test how the assumed distribution of photogenerated carriers and the feedback of trapped charge on carrier transport affect agreement with the measurements. We compare the Langevin partition, which assumes uniform carrier generation across the waveguide, with a partition assuming generation at its center, δ=tanh⁡(Veff/4Vtr)\delta= \tanh(V_{\mathrm{eff}}/4V_{\mathrm{tr}}). Separately, we remove transport feedback by setting Vfb=0V_{\mathrm{fb}} = 0. Each cavity’s loaded QQ remains fixed at its measured value. All variants use the same full optical readout, common tracker, masks, parameter bounds, and equal-power wavelength cost function.

Relative to Langevin, the point-source cost function changes by C1_1: −1.7%, C2_2: −1.7%, C3_3: +0.4%. The upper-power position errors are compared in Table S3. The point-source partition does not consistently lower the full fitting cost function; we retain Langevin because it follows the spatially uniform generation assumption.

ModelC1C_1C2C_2C3C_3
Langevin [Eq. (4)]314.9246.9175.3
Point-source tanh302.1220.4166.6
No feedback (Vfb=0V_{\mathrm{fb}} = 0)635.2517.1447.9

Table S3. Matched quasi-static structural comparisons: position MSE [pm2^2] at 2 nm s−1^{-1} on the three upper powers. All five powers and all three speeds enter the common wavelength cost function. The Langevin baseline is the independent fit in Table S1. The measured QQ values, masks, calibration policy and physical bounds are held fixed except for setting Vfb=0V_{\mathrm{fb}} = 0 in the no-feedback model. Reported candidates have verified attracting continuations; the fold-only restriction and multistart search are described above. The text reports the corresponding changes in the full fitting cost function.

Some no-feedback candidates lose stability through a Hopf bifurcation but do not relax to the proposed destination equilibrium in the fixed-wavelength integration. We exclude these candidates from an equilibrium-branch comparison and restrict the no-feedback search to paths that switch at folds. Within this restricted search, removing feedback increases the lowest-found all-power wavelength cost function by 115–172%. For C1_1, the RMS over the two lowest powers changes from 16.0 to 29.8 pm after refitting. This comparison tests whether one parameter set describes the full power range; it does not measure the direct feedback strength at low power or establish a unique microscopic mechanism. Previously explored parameter sets and fresh perturbations are scored under the common cost function, and eight distinct starting sets per model and cavity are optimized, followed by grid refinement and three additional local starts. All reported parameter sets must produce complete simulated scans that follow stable equilibria and yield every required resonance position. These are lowest-found verified fits, not certified global minima.

Figure S2. Resonance wavelength vs. applied voltage for cavity C3C_3. Symbols and lines as in Figure 4. Mean squared wavelength error: 175.3 pm2^2 (13.24 pm RMS).

Extended-Sweep Validation

We examine whether one set of physical parameters can describe the measurements across all seven scan speeds, then fit the slowest scans on their own. These comparisons use the measured resonance positions to estimate parameters. A separate transfer test holds the physical parameters from the three-cavity dataset fixed and tests them against the scan-speed dataset, as detailed in Supplementary Note 5.4.

Shared Seven-Speed Fit

At each additional scan speed, the protocol covered the same five input powers and 11 voltage steps from −30-30 to +30+30 V in 6 V increments, while C2C_2 and C3C_3 were held at fixed biases of 20 and 40 V, respectively, to prevent their resonances from crossing C1C_1 during tuning and thereby improve resonance tracking. The additional-speed spectra, hysteresis gaps, and fits reported here all use the scan-speed dataset. The number of wavelength samples per 1 nm sweep decreases with scan speed (1000, 1000, 200, and 100 points at 1, 10, 50, and 200 nm s−1^{-1}, that is, 1, 1, 5, and 10 pm per point, compared with the approximately 30 pm linewidth). The 200 nm s−1^{-1} spectra are therefore sampled most coarsely; manual-label validation does not establish a corresponding loss of tracking accuracy (Supplementary Note 4).

Table S4 reports a single fit to all five optical powers and all seven scan speeds for cavity C1C_1. The five physical parameters RR, VtrV_{\mathrm{tr}}, VscV_{\mathrm{sc}}, VfbV_{\mathrm{fb}}, and Vpv0V_{\mathrm{pv0}} have common values across the complete dataset, together with a single bare electro-optic tuning coefficient rVr_V. Only the zero-bias resonance wavelength λ0\lambda_0 varies between measurement runs, allowing for wavelength offsets. The fit has 13 free parameters: five physical parameters, one rVr_V, and seven offsets. The steady-state equations contain no scan-speed-dependent rate parameter. The two acquisitions retain their separately measured loaded quality factors, 5.4×1045.4 \times10^4 for the original 2, 5, and 20 nm s−1^{-1} scans and 5.1×1045.1 \times10^4 for the additional 1, 10, 50, and 200 nm s−1^{-1} scans, and their recorded wavelength windows. The fit uses the wavelength cost function in Supplementary Note 1.2.

RR (mW−1^{-1})VtrV_{\mathrm{tr}} (V)VscV_{\mathrm{sc}} (V)VfbV_{\mathrm{fb}} (V)Vpv0V_{\mathrm{pv0}} (V)rVr_V (pm/V)
36.170.011+19.24−29.19+0.00215.36
AcquisitionSpeed (nm/s)λ0\lambda_0 (nm)RMS (pm)NN
Original21541.58817.396/96
Original51541.58516.895/96
Original201541.58116.696/96
Additional11541.58015.358/66
Additional101541.56917.559/66
Additional501541.56716.058/66
Additional2001541.56517.959/66

Table S4. Shared quasi-static fit to cavity C1C_1 across all seven scan speeds and five input powers, as used in Supplementary Fig. S3. The five physical parameters and rVr_V (top) are common to all speeds; only the fitted wavelength offset (bottom) varies by run. RMS uses the three upper powers, and NN gives retained/available resonance positions at those powers. All rows belong to one joint fit. The three-cavity and scan-speed datasets retain their separately measured loaded quality factors.

The all-power position RMS is 16.32 pm over 859 positions; the upper-power RMS is 16.81 pm over 521 positions and the gap RMS is 20.36 pm over 257 pairs. For the four additional speeds in Supplementary Figure S3, the position and gap RMS values are 16.70 and 19.23 pm over 234 positions and 114 pairs. At 200 nm s−1^{-1} they are 17.86 and 16.10 pm,

Figure S3. Scan-speed dependence and model residuals for cavity C1C_1. (a) Measured resonance positions (symbols) and the shared quasi-static STPR fit (lines) during increasing- (blue) and decreasing-wavelength (gold) sweeps at an estimated cavity-arm input power of −16.8-16.8 dBm. The fit uses all seven C1C_1 scan speeds and all five powers, including the four speeds shown. (b) Differences between the measured and modeled positions (measured minus modeled) for the three upper estimated cavity-arm input powers at the four displayed speeds. Color denotes power, marker shape denotes speed, and the shaded band marks the 16.7 pm pooled RMS residual over 234 positions. The modeled positions are the steepest rising edges extracted from simulated transmission with the same procedure used for the measured spectra.

respectively.

Independent Fit at 1 nm s−1^{-1}

We also fit the 1 nm s−1^{-1} measurements at all five powers on their own, to assess how well the model describes the slowest scans without requiring the same parameters to describe the faster scans. The physical and calibration parameters are estimated using only these measurements, with the wavelength cost function described in Supplementary Note 1.2. Figure S4 shows the resulting curves. Eight starting sets were optimized and three additional local starts were checked; the solution with the smallest cost function value is reported.

Figure S4. Independent quasi-static fit to cavity C1C_1 from the scan-speed dataset described in the main text at 1 nm s−1^{-1}, using the tracking method described in Supplementary Note 4.1, with median agreement of 2.0 pm with the manual reference positions, following the convention of Figure 4. Symbols: measured up-sweep (blue) and down-sweep (gold) resonance wavelengths at the five estimated cavity-arm input powers (−26.8-26.8, −21.8-21.8, −16.8-16.8, −11.8-11.8, and −6.8-6.8 dBm, left to right). Lines: STPR model on the measured voltage grid. The parameters are R=26.28R = 26.28 mW−1^{-1}, Vtr=0.171V_{\mathrm{tr}} = 0.171 V, Vsc=21.65V_{\mathrm{sc}} = 21.65 V, Vfb=−29.17V_{\mathrm{fb}} = -29.17 V, and Vpv0=−0.143V_{\mathrm{pv0}} = -0.143 V, with rV=14.92r_V = 14.92 pm V−1^{-1} and λ0=1541.5789\lambda_0 = 1541.5789 nm. Mean squared wavelength error: 181.3 pm2^2 (13.47 pm RMS over the three upper powers; 13.22 pm over all five).

Supplementary Note 4: Resonance Tracking

The same transmission-edge extraction is used for the three-cavity dataset, the scan-speed dataset, and the simulated spectra. It identifies a reproducible feature of the detected transmission rather than inferring an optical pole from each trace.

Extraction Procedure and Missing Assignments

For each power, acquisition, and sweep direction, we subtract the per-wavelength 40th percentile of the transmission across voltage settings. This removes features that remain approximately stationary as the cavity resonance moves with applied voltage. We smooth each residual spectrum with a Gaussian of 3 pm standard deviation, with a minimum width of 0.6 wavelength samples, and locate positive maxima of its wavelength derivative. A local parabolic interpolation gives the position between samples. The reported coordinate is this steepest rising edge, not the center or half-maximum crossing of a fitted line shape.

Candidate edges must exceed three times the robust derivative-noise scale and have local transmission contrast at least five times the intensity-noise scale. We estimate both noise scales from fluctuations within each spectrum, using median-based measures to reduce the influence of large spectral features. We retain at most eight candidates per spectrum, separated by at least 15 pm. A generalized Fano fit in a ±100 pm neighborhood supplies a line-shape quality score; its fitted center is not used as the resonance coordinate. Across voltage steps, we select a sequence that favors strong, well-shaped edges and smooth wavelength motion. The expected voltage trend is estimated from the spectra themselves, independently for measured and simulated data. The transition scale is 60 pm per voltage step, increasing with the square root of the number of steps when a trace is skipped. The algorithm may leave a spectrum unassigned; it does not interpolate a replacement position or use the other sweep direction to supply one.

Two decreasing-wavelength traces in the original C1C_1 acquisition, at −11.8-11.8 dBm, 2 nm s−1^{-1}, and +14+14 and +18+18 V, require reviewed feature selections. Inspection of the recorded spectra identifies a local resonance edge that the automatic assignment misses or replaces with a later rising flank. For these two traces, we identify the feature window manually and apply the same smoothed-derivative calculation within that window. The windows are chosen from the spectra, without using model predictions. The original automatic coordinates and flags are retained in the data record; both fits that reuse these measurements use the reviewed coordinates.

We exclude seventeen increasing-wavelength spectra clipped by source-laser mode hops (sixteen for C2C_2 and one for C3C_3). Spectra for which the tracking procedure returns no resonance position are also omitted from the fits. The independent fits contain 477, 456, and 477 positions for C1C_1, C2C_2, and C3C_3, respectively; the seven-speed fit contains 859 positions. The raw spectra, extracted positions, and resonance masks are retained in the analysis record.

An assignment is flagged as ambiguous if forbidding it increases the best complete tracking-path score by less than 0.5. This flag measures competition between candidate sequences; it is not a calibrated probability. Finite flagged positions remain in the fits. We also refit after excluding them as a separate sensitivity check (Supplementary Note 5.2).

Validation and Model Readout

We selected 427 spectra across the four additional scan speeds, prioritizing cases flagged as uncertain by an earlier diagnostic. We used the manual labels for these spectra to develop and assess the extraction method. The common tracker returns a position for all 427 spectra, with two ambiguity flags. Its median absolute difference from the manual positions is 2.0 pm, the RMS difference is 4.0 pm, and the largest difference is 18.6 pm. These labels informed development of the procedure and are not an independent test set.

The modeled transmission is sampled on the experimental wavelength and voltage grids and passed through the identical extraction procedure. Its voltage trend is estimated from its own spectra, without using the measured positions to select model features. All retained experimental positions must have finite modeled counterparts. A candidate parameter set is rejected if the scan path cannot be completed on attracting states or the tracker cannot assign a required modeled position. A sharp falling switch can coexist with a broad rising flank: the reported coordinate remains the selected rising edge in that case. The fitted wavelength offset can accommodate a common calibration shift, but the marker should not be interpreted as an intrinsic cavity pole or as every branch-switching point.

Fit Robustness and Identifiability

We assess how perturbing the measured data changes the fitted parameters and predicted resonance wavelengths. We also test predictions at additional scan speeds and examine which parameters can be determined from steady-state data.

Search Bounds and Steady-State Identifiability

The physical bounds are 0.01≤R≤100 mW−10.01 \le R \le100\ \mathrm{mW}^{-1}, 0.01≤Vtr≤10 V0.01 \le V_{\mathrm{tr}} \le10\ \mathrm{V}, 0.1≤Vsc≤300 V0.1 \le V_{\mathrm{sc}} \le300\ \mathrm{V}, −400≤Vfb≤0 V-400 \le V_{\mathrm{fb}} \le0\ \mathrm{V}, and −5≤Vpv0≤5 V-5 \le V_{\mathrm{pv0}} \le5\ \mathrm{V}. The selected fits lie inside these bounds, but the independent C1C_1 and seven-speed fits give Vtr≃0.011 VV_{\mathrm{tr}} \simeq0.011\ \mathrm{V}, close to its lower bound. Sensitivity to this choice is examined in Supplementary Note 5.5. Common rescaling of g0g_0 and krelk_{\mathrm{rel}} is an exact invariance of the steady-state equations: separate absolute rates cannot be recovered even from noise-free static data. Practical compensation among RR, VtrV_{\mathrm{tr}} and the two voltage coefficients further limits interpretation of the fitted point estimates.

Sensitivity to Ambiguous Assignments

We repeated the three independent cavity fits and the seven-speed fit after excluding the finite positions flagged as ambiguous by the common tracker. This removes 21, 7, and 1 positions from the independent C1C_1, C2C_2, and C3C_3 fits, and 23 from the seven-speed fit. The predicted positions change by 1.60, 0.10, less than 0.01, and less than 0.01 pm RMS, respectively, evaluated on the original retained position sets. This checks sensitivity to competing feature assignments without treating the tracking-path score as a statistical confidence level.

Conditional Resampling and Tracking Sensitivity

Residual resampling. We assessed parameter sensitivity by generating 512 artificial datasets for each of the three independent cavity fits and the shared seven-speed fit. We first calculated the residual between each measured resonance position and the selected model prediction. To construct an artificial dataset, we randomly retained or reversed the signs of those residuals and added them to the model predictions. Residuals at four adjacent voltage levels within an acquisition shared one random sign across optical powers and sweep directions, so nearby errors varied together. This construction adapts wild residual resampling [27] by assigning a common random sign within each block, as in the wild cluster bootstrap [28]. The four-voltage block definition is a choice for this sensitivity analysis.

We then refitted the five physical parameters, the common rVr_V, and the wavelength offsets using the same bounds and equal-power wavelength cost function as the original fit, with the optical coefficients held fixed. For each artificial dataset, we refined the original parameter set and two distinct alternatives selected by their error on that dataset, followed by a separate least-squares refinement. Additional searches along parameter-coordinate and random directions were applied to every dataset. A final check of regularly spaced draws and parameter extremes changed the percentile interval endpoints by at most 2.1% of their preceding interval widths. Following the same draws that defined those endpoints gave a conservative maximum change of 5.7%. Lower-error valid solutions were retained; no artificial dataset was discarded or replaced because of a difficult fit. These checks assess numerical stability, not uniqueness or global optimality.

Parameter ranges and predicted positions. The reported ranges span the 2.5th to 97.5th percentiles of the resulting parameter estimates. They describe sensitivity to residual perturbations under fixed input-power calibration, loaded quality factors, optical readout, extraction settings, reviewed feature selections, exclusion masks, and scan initialization. They are conditional on the model and resampling scheme, not confidence intervals for microscopic trap parameters. For C1C_1, C2C_2, C3C_3, and the seven-speed C1C_1 fit, respectively, the median RMS changes in predicted positions are 3.17, 3.50, 3.05, and 3.14 pm; their 97.5th percentiles are 5.36, 5.69, 4.58, and 4.66 pm. Correlations between VtrV_{\mathrm{tr}} and Vfb/VscV_{\mathrm{fb}}/V_{\mathrm{sc}} are 0.675, 0.869, 0.960, and 0.857, indicating compensation between the transport scale and the voltage-coefficient ratio. The transport scale approaches its lower search bound in 77 of 512 C1C_1 refits (15.0%) and 72 seven-speed refits (14.1%). Their lower percentile limits are therefore constrained by the search range. No other fitted parameter approaches a bound within 10−410^{-4} of its transformed search-range width; RR and VtrV_{\mathrm{tr}} are tested in logarithmic coordinates. Sensitivity to the allowed transport scale and to sharing it across cavities is assessed separately in Supplementary Note 5.5.

Wavelength sampling and numerical checks. A separate 256-refit sampling-resolution study perturbed only the scan-speed dataset, using correlated common and opposite-direction offsets bounded by half the recorded wavelength-grid spacing. Relative to the adopted nominal curve, the median RMS prediction change is 0.970 pm and its 97.5th percentile is 0.984 pm. Further refinement of the unperturbed fit changes its curve by 0.962 pm, so the sampling result is comparable to the numerical refinement scale and does not establish a precise physical uncertainty. Relative to that refined unperturbed curve, the sampling-refit changes have a median RMS of 0.290 pm and a 97.5th percentile of 1.004 pm. Sensitivity to ambiguous assignments is assessed in Supplementary Note 5.2; separate power and quality-factor scenarios follow below.

All 2,304 selected refits return every required transmission marker. Doubling the geometry grid from 801 to 1601 points changes any extracted wavelength by at most 0.028 pm. An independent calculation checks 6,480 scan trajectories from 36 parameter sets spanning the fitted parameter and prediction extremes. All 1,355 tested fixed-wavelength integrations relax to the selected equilibrium, and the extracted wavelengths agree within 0.014 pm. This check does not integrate every jump for every resample.

Two extreme seven-speed resamples admit a second stable equilibrium at the recorded beginning of the 1 ms−1^{-1}, −21.8-21.8 dBm, +30+30 V decreasing-wavelength scan. Following that alternative branch gives no extractable rising edge in the recorded window, whereas the adopted branch reproduces the measured feature. Both resamples are retained. The analysis therefore remains conditional on the stated far-from-resonance initialization; it does not assume a unique equilibrium at every recorded scan boundary. These ranges describe the extracted-position fit, not uncertainty bands for complete spectra, and do not include unmodeled spectral physics.

Supplementary Table S6. Additional conditional ranges from the same residual refits as Table S5. Entries give the selected value followed by the 2.5th–97.5th percentiles; all parameters are in volts.

DatasetVscV_{\mathrm{sc}}VfbV_{\mathrm{fb}}VpvV_{\mathrm{pv}}
C1C_119.18 [18.13, 21.51]−28.76 [−30.61, −27.16]0.411 [0.088, 0.786]
C2C_220.91 [19.74, 24.38]−31.08 [−33.44, −28.68]0.257 [−0.025, 0.515]
C3C_320.68 [19.17, 23.04]−29.93 [−31.67, −27.23]0.350 [0.058, 0.616]
C1C_1, seven speeds19.24 [18.22, 22.04]−29.19 [−30.52, −27.53]0.002 [−0.225, 0.220]

Table S6.

Supplementary Table S5. Conditional parameter ranges from 512 correlated residual refits per dataset, with input power, loaded QQ and optical readout fixed. Entries give the selected value followed by the 2.5th–97.5th percentiles. The lower VtrV_{\mathrm{tr}} limits for C1C_1 and its seven-speed fit are constrained by the search bound.

DatasetRR (mW−1^{-1})VtrV_{\mathrm{tr}} (V)Vfb/VscV_{\mathrm{fb}}/V_{\mathrm{sc}}
C1C_139.01 [29.03, 45.20]0.011 [0.010, 0.056]−1.499 [−1.542, −1.414]
C2C_222.46 [18.06, 25.48]0.101 [0.058, 0.371]−1.486 [−1.578, −1.260]
C3C_322.88 [19.60, 26.20]0.170 [0.086, 0.382]−1.447 [−1.541, −1.266]
C1C_1, seven speeds36.17 [28.17, 41.63]0.011 [0.010, 0.139]−1.517 [−1.547, −1.381]

Table S5.

DatasetSpeed (nm s−1^{-1})rVr_V (pm V−1^{-1})λ0\lambda_0 (nm)
C1C_1215.56 [15.31, 15.78]1541.5898 [1541.5854, 1541.5946]
C1C_1515.56 [15.31, 15.78]1541.5859 [1541.5814, 1541.5910]
C1C_12015.56 [15.31, 15.78]1541.5838 [1541.5790, 1541.5887]
C2C_2215.68 [15.39, 16.01]1541.8712 [1541.8650, 1541.8767]
C2C_2515.68 [15.39, 16.01]1541.8662 [1541.8616, 1541.8710]
C2C_22015.68 [15.39, 16.01]1541.8646 [1541.8613, 1541.8678]
C3C_3215.67 [15.46, 15.88]1541.5639 [1541.5585, 1541.5690]
C3C_3515.67 [15.46, 15.88]1541.5605 [1541.5557, 1541.5653]
C3C_32015.67 [15.46, 15.88]1541.5562 [1541.5516, 1541.5603]
C1C_1, seven speeds115.36 [15.12, 15.52]1541.5802 [1541.5763, 1541.5837]
C1C_1, seven speeds215.36 [15.12, 15.52]1541.5884 [1541.5831, 1541.5931]
C1C_1, seven speeds515.36 [15.12, 15.52]1541.5847 [1541.5800, 1541.5892]
C1C_1, seven speeds1015.36 [15.12, 15.52]1541.5695 [1541.5651, 1541.5740]
C1C_1, seven speeds2015.36 [15.12, 15.52]1541.5810 [1541.5754, 1541.5862]
C1C_1, seven speeds5015.36 [15.12, 15.52]1541.5670 [1541.5629, 1541.5713]
C1C_1, seven speeds20015.36 [15.12, 15.52]1541.5654 [1541.5602, 1541.5688]

Table S7. Supplementary Table S7. Conditional calibration ranges from the same residual refits. Entries give the selected value followed by the 2.5th–97.5th percentiles. Each fit shares rVr_V across its scan speeds; repeated entries denote one fitted coordinate.

Input-power and linewidth sensitivity. A common multiplicative error in the input-power calibration is exactly absorbed by an inverse rescaling of RR: changing every power by a factor cPc_P and replacing RR by R/cPR/c_P leaves the steady-state predictions unchanged, provided the transformed parameter remains within the search bounds. Numerical checks at common power shifts of ±1\pm1 dB give identical positions; these shifts are illustrative scenarios, not measured calibration uncertainties. The inferred generation-to-release ratio therefore depends on the absolute power calibration even when the fit is unchanged.

We separately refitted all four datasets after common loaded-QQ shifts of ±5%\pm5\% and ±10%\pm10\%, keeping the masks, optical readouts, bounds, and wavelength cost function fixed. The predicted positions change by 1.4–1.7 pm RMS for the 5% shifts and 2.2–3.3 pm RMS for the 10% shifts. Some fitted parameters change much more than the predicted curves. For example, reducing QQ by 10% in the C2C_2 fit changes VtrV_{\mathrm{tr}} from 0.101 to 0.263 V. Similar resonance curves therefore do not establish a precisely determined transport scale. All 16 reported refits converge and provide every required modeled marker on a complete attracting path. When a shifted-QQ starting point lacks a required marker, we screen alternative starting sets for complete scan paths. We check the nominal parameters and starting sets with both small and large transport scales, with six additional perturbed starts for the 10% shifts. These are hypothetical calibration scenarios, not measured uncertainties in QQ.

Frozen-Parameter Transfer to the Additional Scans

A separate transfer test holds the five physical parameters from the C1C_1 fit to the three-cavity dataset fixed. Using only the two lowest input powers, we fit one common electro-optic tuning coefficient rVr_V across the four additional scan speeds and a separate reference wavelength λ0\lambda_0 for each acquisition. This gives rV=15.32r_V = 15.32 pm V−1^{-1}. At the three higher powers, which do not enter this calibration, the RMS errors are 15.8, 18.8, 18.7, and 21.7 pm at 1, 10, 50, and 200 nm s−1^{-1}, respectively, with a pooled RMS of 18.9 pm. The comparison is conditional on the fixed optical readout calibrated in the primary analysis; it is not an independent test of the complete extraction and calibration workflow.

Sensitivity of the Transport Scale

To assess how precisely the measurements determine the shared transport scale, we fix VtrV_{\mathrm{tr}} at 0.01, 0.03, 0.1, 0.3, and 1 V and refit the remaining parameters. Each calculation uses the same wavelength cost function and retained observations as the shared-cavity fit, with three starting parameter sets. Over 0.01–0.3 V, the cost function increases by at most 3.5% and the predicted resonance wavelengths change by at most 3.2 pm RMS relative to the shared-cavity fit. At 1 V, these changes are 13.8% and 5.8 pm. Thus substantially different transport scales can describe similar resonance curves, although the larger tested value gives poorer agreement. These fixed-value tests assess sensitivity; the tested range is not a confidence interval.

Carrier-Partition Models and Self-Quenching

We compare transverse carrier-generation profiles and test how transport feedback shapes the steady trap response.

Uniform, Mode-Like, and Point-Source Carrier Partitions

For a normalized transverse generation profile G(ξ)G(\xi), with ξ∈[0,1]\xi\in[0,1] and ∫01G(ξ) dξ=1\int_{0}^{1} G(\xi)\,\mathrm{d}\xi= 1, the partition asymmetry is

δG=2∫01G(ξ)u(ξ) dξ−1,(13)\delta_G = 2\int_{0}^{1} G(\xi)u(\xi)\,\mathrm{d}\xi- 1, \tag*{(13)}

where u(ξ)=(1−e−Peξ)/(1−e−Pe)u(\xi) = (1-e^{-\mathrm{Pe}\xi})/(1-e^{-\mathrm{Pe}}) is the right-sidewall first-passage probability. Uniform generation, G(ξ)=1G(\xi)=1, gives the exact Langevin result δ=L(Veff/2Vtr)\delta=L(V_{\mathrm{eff}}/2V_{\mathrm{tr}}) used in the main-text model. A centered point source, G(ξ)=δD(ξ−1/2)G(\xi)=\delta_{\mathrm{D}}(\xi-1/2), instead gives

δpoint=tanh⁡(Veff4Vtr)=tanh⁡(χ/2),χ≡Veff2Vtr.(14)\delta_{\mathrm{point}}=\tanh\left(\frac{V_{\mathrm{eff}}}{4V_{\mathrm{tr}}}\right)=\tanh(\chi/2),\qquad\chi\equiv\frac{V_{\mathrm{eff}}}{2V_{\mathrm{tr}}}. \tag*{(14)}

To estimate the sensitivity to optical localization without introducing an additional fitted profile parameter, we evaluate Eq. (13) for two representative symmetric, centered profiles: Gs(ξ)=2sin⁡2(πξ)G_s(\xi)=2\sin^2(\pi\xi) and a normalized Gaussian intensity profile with full width at half maximum equal to half the waveguide width. At the representative drift-dominated values χ=10\chi=10, 2020, and 3030, the uniform profile gives δ=0.900\delta=0.900, 0.9500.950, and 0.9670.967, the Gaussian gives 0.9780.978, 0.9920.992, and 0.9950.995, the sine-squared profile gives 0.9910.991, 0.9990.999, and 1.0001.000, and the centered point source is effectively unity. The mode-like profiles therefore increase δ\delta by 2.9–10.1% relative to uniform generation, with the largest increase at the smallest χ\chi, while remaining within 2.2% of the point-source limit. The assumed transverse profile has a few-percent effect on the nearly saturated partition at χ≳20\chi\gtrsim20, and the uniform-generation model provides the conservative value among these centered profiles.

Generation profileχ=10\chi=10χ=20\chi=20χ=30\chi=30
Uniform (Langevin)0.9000.9500.967
Gaussian0.978 (8.7%)0.992 (4.4%)0.995 (2.9%)
2sin⁡2(πξ)2\sin^2(\pi\xi)0.991 (10.1%)0.999 (5.2%)1.000 (3.4%)
Centered point source1.000 (11.1%)1.000 (5.3%)1.000 (3.4%)

Table S8. Sensitivity of the carrier partition asymmetry δ\delta to the transverse photocarrier-generation profile at representative effective drift voltages. Values in parentheses give the increase relative to uniform generation.

Uniqueness and Stability at Fixed Optical Drive

Hold VappV_{\mathrm{app}} and Peff>0P_{\mathrm{eff}}>0 fixed, and write G=g0Peff>0G=g_0P_{\mathrm{eff}}>0, k=krel>0k=k_{\mathrm{rel}}>0, x=Δsx=\Delta s, and δ(x)=L[(Vapp+Vpv0+Vfbx)/(2Vtr)]\delta(x)=L[(V_{\mathrm{app}}+V_{\mathrm{pv0}}+V_{\mathrm{fb}}x)/(2V_{\mathrm{tr}})], with Vtr>0V_{\mathrm{tr}}>0 and Vfb<0V_{\mathrm{fb}}<0. The steady occupancies are s±ss=Gp±/(Gp±+k)s_{\pm}^{\mathrm{ss}}=Gp_{\pm}/(Gp_{\pm}+k), where p±=(1±δ)/2p_{\pm}=(1\pm\delta)/2. Their difference gives the exact relation

xss=F(xss),F(x)=4Gk δ(x)(G+2k)2−G2δ(x)2.(15)x^{\mathrm{ss}}=F(x^{\mathrm{ss}}),\qquad F(x)=\frac{4Gk\,\delta(x)}{(G+2k)^2-G^2\delta(x)^2}. \tag*{(15)}

Existence and uniqueness. The right-hand side increases with δ\delta, whereas δ′(x)<0\delta'(x)<0 because L′>0L'>0 and Vfb<0V_{\mathrm{fb}}<0. Thus FF is continuous and decreasing, with ∣F∣<1|F|<1 since both steady occupancies lie in (0,1)(0,1). Consequently, x−F(x)x-F(x) is strictly increasing, negative at x=−1x=-1, and positive at x=1x=1, giving exactly one physical steady state.

Stability. Differentiating both trap equations gives the 2×22\times2 Jacobian JJ at a steady state. Its off-diagonal entries are nonnegative because δ′<0\delta'<0 and 1−s±ss>01-s_{\pm}^{\mathrm{ss}}>0, and its row sums obey

J(11)=−(Gp++kGp−+k).(16)J\begin{pmatrix}1\\1\end{pmatrix}=-\begin{pmatrix}Gp_{+}+k\\Gp_{-}+k\end{pmatrix}. \tag*{(16)}

Every Gershgorin disc therefore lies strictly in the left half-plane, so the steady state is locally asymptotically stable. At G=0G = 0, the unique steady state is s±=0s_{\pm} = 0, with decay rate kk.

This proof assumes externally fixed PeffP_{\mathrm{eff}}. In the coupled cavity model, PeffP_{\mathrm{eff}} depends on Δs\Delta s through detuning, so optical feedback can permit multiple steady states. The occupancy bounds 0≤s±≤10 \le s_{\pm} \le1 still imply ∣Δs∣≤1|\Delta s| \le1, independently of uniqueness.

Cavity Feedback and Directional Branches

Dividing the numerator and denominator in Eq. (15) by k2k^2 gives Eq. (10), with a=G/k=RPeffa = G/k = RP_{\mathrm{eff}}. The fixed-power uniqueness proof does not select the branch of the coupled optical system. For that purpose, we differentiate the original two occupancy equations at fixed laser wavelength, allowing both Peff(Δs)P_{\mathrm{eff}}(\Delta s) and δ(Δs)\delta(\Delta s) to vary. A locally attracting steady state has both Jacobian eigenvalues in the left half-plane. The full Jacobian equals krelk_{\mathrm{rel}} times a matrix depending only on RR and the other steady-state parameters, so positive common rate scaling changes relaxation times but not stability signs or fixed-wavelength relaxation paths.

The incoming attracting branch is followed until it loses stability. The next state is selected by relaxation of the SRH rate equations, rather than by an assumed free-energy minimum or the fixed-power slope alone. Figure 3 shows how hysteresis develops as the input power increases. Other tested conditions can lose stability differently; the numerical rule checks the full Jacobian rather than assuming every jump occurs at a fold. The switching interval in Figure 3 is distinct from the up/down resonance-position gap, which uses the selected rising edges of the detected transmission features.

Supplementary Note 7: Measured Spectra and Model Waterfalls

Supplementary Figs. S5 and S6 compare measured spectra with the standard STPR pole trajectories passed through an effective reciprocal 3×33 \times3 interferometric readout. The cavity-specific loaded QQ values are estimated from Fano fits to the measured resonances; the waterfall readout itself has no fitted Fano line shape. The physical STPR parameters are fixed by the resonance-position fits. The Figure 1(c) acquisition retains its archived low-power wavelength calibration, as specified below. The optical parameters and detector-port assignment are shared across voltages, sweep directions, and outputs within each acquisition. For the control, we set Vsc=0V_{\mathrm{sc}} = 0 to remove the photorefractive resonance shift while retaining the same optical readout and displayed gain. The figures label this control PR offPR\ off. These are calibrated, effective isolated-cavity readouts, not independently calibrated predictions of absolute three-port transmission.

Following the transfer-matrix description of the 3×33 \times3 switch [11], we denote the forward MMI transfer matrix by M\mathbf{M} and the effective arm reflections by R=diag⁡(r1,r2,r3)\mathbf{R} = \operatorname{diag}(r_1,r_2,r_3). Reciprocity gives the return-pass matrix MT\mathbf{M}^{\mathsf{T}}, so the round-trip response is

T=MTRM,Eout=TE0,Pj=Gj∣Eout,j∣2.(17)\mathbf{T} = \mathbf{M}^{\mathsf{T}}\mathbf{R}\mathbf{M}, \qquad\mathbf{E}_{\mathrm{out}} = \mathbf{T}\mathbf{E}_0, \qquad P_j = G_j \lvert E_{\mathrm{out},j} \rvert^2 . \tag*{(17)}

We use the ideal equal-split convention Mjk=3−1/2exp⁡(2πijk/3)M_{jk} = 3^{-1/2}\exp(2\pi i jk/3) for j,k∈{0,1,2}j,k \in\{0,1,2\}, with input at port 0. The resonant arm has response rc=exp⁡(iβVapp)[1−2η/(1+i(λ−λc)/γ)]r_c = \exp(i\beta V_{\mathrm{app}})[1 - 2\eta/(1 + i(\lambda- \lambda_c)/\gamma)], where λc\lambda_c is the instantaneous cavity resonance and γ=λ0/(2Q)\gamma= \lambda_0/(2Q). The other two arms have effective responses exp⁡{i[ϕm+sm(λ−λ∗)]}\exp\{i[\phi_m + s_m(\lambda- \lambda_*)]\}. The port assignment is fixed within each acquisition. Coherent mixing in Eq. (17) generates the asymmetric spectral features without a separate Fano fit at every voltage.

For the resonance-position fits, we calibrate the existing eight optical coefficients (η\eta, two reference-arm amplitudes, two phases, two wavelength slopes, and β\beta) separately for the original C1C_1, C2C_2, and C3C_3 acquisitions and the later C1C_1 acquisition. The detector indices are 0, 2, 1, and 1, respectively (zero-based indexing); their optical port assignments are fixed. Calibration uses the lowest-power spectra at 2 nm s−12\ \mathrm{nm\,s^{-1}} for the original acquisitions and 1 nm s−11\ \mathrm{nm\,s^{-1}} for the later acquisition, with alternating voltage rows used for fitting. A preliminary steady-state trajectory is held fixed while estimating the readout. The full intensity from Eq. (17) is evaluated before applying the identical 40th-percentile background subtraction to measured and simulated sequences. We do not remove a cavity-free model response before tracking.

The calibrated readout is then held fixed during all resonance-position fits and residual resamples. Its coefficients describe an effective interferometric response, not uniquely measured arm properties; some coefficients reach their calibration bounds. The conditional parameter ranges do not include uncertainty in this optical calibration. Background estimation uses all voltage rows, so interleaved-row spectral checks are conditional on that common preprocessing.

Figure 5 uses the C3C_3 parameters in Table S1, its fixed optical coefficients, and one positive gain calibrated on alternating voltage rows at the displayed power. Measured and modeled display traces receive the same 40th-percentile background subtraction and share a vertical normalization at each voltage. Each trace error is its RMS residual over

1540.98–1542.20 nm, normalized by the measured up/down pair’s 1st–99th percentile span. The median normalized trace errors are 9.4% on the calibration rows and 10.3% on the interleaved rows; the RMS across all 32 trace errors is 10.3%.

Supplementary Figure S5 uses the same physical parameters, reference-arm coefficients, detector assignment and positive gain as Figure 5. The zero-shift control retains that calibration and gain. The same 40th-percentile background is subtracted from each sequence, with no individually fitted trace gain, offset, phase or wavelength shift. Errors use a voltage-dependent window within ±0.3 nm of the archived electro-optic tuning line, whereas Figure 5 uses the fixed 1540.98–1542.20 nm window. Both use the measured up/down pair’s 1st–99th percentile span for normalization. The different windows give different error statistics for the same spectra. For Figure S5, the median over 32 traces is 12.4% for steady-state STPR and 39.6% for the control; RMS across traces is 13.1% and 40.6%, respectively.

Figure S5. Measured spectra (colored by applied voltage) and modeled spectra (black) for cavity C3C_3 at 2 nm s−12\ \mathrm{nm}\ \mathrm{s}^{-1} and an estimated cavity-arm input power of −11.8 dBm-11.8\ \mathrm{dBm}. (a,b) STPR model combined with the three-arm interferometer model for increasing- and decreasing-wavelength sweeps; (c,d) control with zero photorefractive shift and the same readout and gain as Figure 5. Median normalized trace errors in the supplementary scoring windows are 12.4% and 39.6%, respectively.

For Supplementary Figure S6, the physical C1C_1 parameters are fixed at the values used in Figure 4. We fit rVr_V and λ0\lambda_0 to this acquisition’s extracted resonance wavelengths at the two lowest input powers, using the same equal-power wavelength cost function. This gives rV=14.89 pm V−1r_V = 14.89\ \mathrm{pm}\ \mathrm{V}^{-1} and λ0=1541.5710 nm\lambda_0 = 1541.5710\ \mathrm{nm}. The eight interferometer coefficients, determined from the two lowest-power spectra using alternating voltages, both scan directions, and detector 1, remain fixed. One positive gain per calibration power is shared across its voltages and directions. At the displayed power, one positive gain is fitted on alternating voltages and held fixed for both the STPR and zero-shift predictions. This is a calibrated spectral comparison rather than an entirely held-out power test. Both measured and modeled full intensities receive the same 40th-percentile background subtraction, with no individual trace gain, phase, offset, or wavelength shift.

Figure S6. Measured spectra of the acquisition shown in Figure 1(c) (cavity C1C_1, 1 nm s−11\ \mathrm{nm}\ \mathrm{s}^{-1}, estimated cavity-arm input power −16.8 dBm-16.8\ \mathrm{dBm}, all 11 voltage steps), with the fixed effective 3×33 \times3 readout. Colored curves are measured; black curves are modeled. (a,b) Quasi-static STPR for increasing- and decreasing-wavelength sweeps; (c,d) control with zero photorefractive shift and the same optical readout and gain. Up and down sweeps at each voltage use the same measured-percentile display scale; neither model curve is clipped or shifted. The down-sweep panels omit the scan-start discontinuity above 1541.975 nm; the omitted samples are also excluded from the error metric. Median normalized errors are 12.5% and 27.4%, respectively.

The initial 1541.975–1542.0 nm portion of decreasing sweeps is excluded because of a reproducible scan-start discontinuity; increasing sweeps retain 1541.145–1542.0 nm. Each trace error is the RMS difference over displayed samples normalized by the measured up/down pair’s 1st–99th percentile span. The median over 22 traces is 12.5% for

STPR and 27.4% with the photorefractive shift set to zero. The scoring window differs from Supplementary Fig. S5.

References

  1. [1]Cheng Wang, Mian Zhang, Xi Chen, Maxime Bertrand, Amirhassan Shams-Ansari, Sethumadhavan Chandrasekhar, Peter Winzer, and Marko Lončar. Integrated lithium niobate electro-optic modulators operating at CMOS-compatible voltages. Nature, 562(7725):101–104, 2018. doi: 10.1038/s41586-018-0551-y.
  2. [2]Andreas Boes, Lin Chang, Carsten Langrock, Mengjie Yu, Mian Zhang, Qiang Lin, Marko Lončar, Martin Fejer, John Bowers, and Arman Mitchell. Lithium niobate photonics: Unlocking the electromagnetic spectrum. Science, 379(6627):eabi4396, 2023. doi: 10.1126/science.abi4396.DOI
  3. [3]Di Zhu, Linbo Shao, Mengjie Yu, Rebecca Cheng, Boris Desiatov, C. Jae Xin, Yaowen Hu, Jeffrey Holzgrafе, Soumya Ghosh, Amirhassan Shams-Ansari, Eric Puma, Neil Sinclair, Christian Reimer, Mian Zhang, and Marko Lončar. Integrated photonics on thin-film lithium niobate. Adv. Opt. Photon., 13(2):242–352, 2021. doi: 10.1364/AOP.411024.DOI
  4. [4]Mian Zhang, Brandon Buscaino, Cheng Wang, Amirhassan Shams-Ansari, Christian Reimer, Rongrong Zhu, Joseph M. Kahn, and Marko Lončar. Broadband electro-optic frequency comb generation in a lithium niobate microring resonator. Nature, 568(7752):373–377, 2019. doi: 10.1038/s41586-019-1008-7.DOI
  5. [5]Nicolas Englebert, Robert M. Gray, Alireza Marandi, Markku Vainio, Zheng Gong, Hong X. Tang, and Dmitry V. Skryabin. Temporal solitons and frequency combs in quadratic resonators. Nat. Photonics, 20(6):616–627, 2026. doi: 10.1038/s41566-026-01902-6.DOI
  6. [6]Timothy P. McKenna, Jeremy D. Withmer, Rishi N. Patel, Wentao Jiang, Raphaël Van Laer, Patricio Arrangoiz-Arriola, E. Alex Wollack, Jason F. Herrmann, and Amir H. Safavi-Naeini. Cryogenic microwave-to-optical conversion using a triply resonant lithium-niobate-on-sapphire transducer. Optica, 7(12):1737–1745, 2020. doi: 10.1364/OPTICA.397235.DOI
  7. [7]Jeffrey Holzgrafe, Neil Sinclair, Di Zhu, Amirhassan Shams-Ansari, Marco Colangelo, Yaowen Hu, Mian Zhang, Karl K. Berggren, and Marko Lončar. Cavity electro-optics in thin-film lithium niobate for efficient microwave-to-optical transduction. Optica, 7(12):1714–1720, 2020. doi: 10.1364/OPTICA.397513.DOI
  8. [8]Haowei Jiang, Hanxiao Liang, Rui Luo, Xianfeng Chen, Yuping Chen, and Qiang Lin. Nonlinear frequency conversion in one dimensional lithium niobate photonic crystal nanocavities. Appl. Phys. Lett., 113(2):021104, 2018. doi: 10.1063/1.5039948.DOI
  9. [9]Mingxiao Li, Jingwei Ling, Yang He, Usman A. Javid, Shixin Xue, and Qiang Lin. Lithium niobate photonic-crystal electro-optic modulator. Nat. Commun., 11(1):4123, 2020. doi: 10.1038/s41467-020-17950-7.DOI
  10. [10]Hugo Larocque, Dashiell L. P. Vitullo, Alexander Sludds, Hamed Sattari, Ian Christen, Gregory Choong, Iván Prieto, Jacopo Leo, Homa Zarebidaki, Sanjaya Lohani, Brian T. Kirby, Öney Soykal, Mo Soltani, Amir H. Ghadimi, Dirk R. Englund, and Mikkel Heuck. Photonic crystal cavity IQ modulators in thin-film lithium niobate. ACS Photonics, 11(9):3860–3869, 2024. doi: 10.1021/acsphotonics.4c01138.DOI
  11. [11]Alessandro Buzzi, Bjarke A. Frederiksen, Dashiell L. P. Vitullo, Mikkel Heuck, and Dirk R. Englund. Multiport photonic routing with a single cavity-based electro-optic phase shifter per port. arXiv:2610.31757 [physics.optics], 2026.arxiv.org/abs/2610.31757
  12. [12]A. Ashkin, G. D. Boyd, J. M. Dziedzic, R. G. Smith, A. A. Ballman, J. J. Levinstein, and K. Nassau. Optically-induced refractive index inhomogeneities in LiNbO₃ and LiTaO₃. Appl. Phys. Lett., 9(1):72–74, 1966. doi: 10.1063/1.1754607.DOI
  13. [13]N. V. Kukhtarev, V. B. Markov, S. G. Odulov, M. S. Soskin, and V. L. Vinetskii. Holographic storage in electrooptic crystals. I. Steady state. Ferroelectrics, 22(1):949–960, 1979. doi: 10.1080/00150197908239450.DOI
  14. [14]Yuntao Xu, Mohan Shen, Juanjuan Lu, Joshua B. Surya, Ayed Al Sayem, and Hong X. Tang. Mitigating photorefractive effect in thin-film lithium niobate microring resonators. Opt. Express, 29(4):5497–5504, 2021. doi: 10.1364/OE.418877.DOI
  15. [15]Ran Yin, Yue Yu, Chunho Lee, Ian Christen, Zaijun Chen, and Mengjie Yu. Fundamental phase noise in thin film lithium niobate resonators. Laser Photonics Rev., page e71681, 2026. doi: 10.1002/lpor.71681.DOI
  16. [16]A. A. Savchenkov, A. B. Matsko, D. Strekalov, V. S. Ilchenko, and L. Maleki. Enhancement of photorefraction in whispering gallery mode resonators. Phys. Rev. B, 74(24):245119, 2006. doi: 10.1103/PhysRevB.74.245119.DOI
  17. [17]Markus Leidinger, Christoph S. Werner, Wataru Yoshiki, Karsten Buse, and Ingo Breuning. Impact of the photorefractive and pyroelectric-electro-optic effect in lithium niobate on whispering-gallery modes. Opt. Lett., 41(23):5474–5477, 2016. doi: 10.1364/OL.41.005474.DOI
  18. [18]Yuntao Xu, Ayed Al Sayem, Chang-Ling Zou, Linran Fan, Risheng Cheng, and Hong X. Tang. Photorefraction-induced Bragg scattering in cryogenic lithium niobate ring resonators. Opt. Lett., 46(2):432–435, 2021. doi: 10.1364/OL.414702.DOI
  19. [19]Hanxiao Liang, Rui Luo, Yang He, Haowei Jiang, and Qiang Lin. High-quality lithium niobate photonic crystal nanocavities. Optica, 4(10):1251–1258, 2017. doi: 10.1364/OPTICA.4.001251.DOI
  20. [20]Mingxiao Li, Hanxiao Liang, Rui Luo, Yang He, Jingwei Ling, and Qiang Lin. Photon-level tuning of photonic nanocavities. Optica, 6(7):860–863, 2019. doi: 10.1364/OPTICA.6.000860.DOI
  21. [21]A. M. Glass, D. von der Linde, and T. J. Negran. High-voltage bulk photovoltaic effect and the photorefractive process in LiNbO₃. Appl. Phys. Lett., 25(4):233–235, 1974. doi: 10.1063/1.1655453.DOI
  22. [22]Crispin W. Gardiner. Handbook of Stochastic Methods for Physics, Chemistry and the Natural Sciences. Springer-Verlag, Berlin, 3rd edition, 2004. ISBN 978-3-540-20882-2.
  23. [23]William Shockley and William T. Read. Statistics of the recombinations of holes and electrons. Phys. Rev., 87(5):835–842, 1952. doi: 10.1103/PhysRev.87.835.DOI
  24. [24]Jie Wang, Bowen Zhu, Zhenzhong Hao, Fang Bo, Xiaolei Wang, Feng Gao, Yigang Li, Guoquan Zhang, and Jingjun Xu. Thermo-optic effects in on-chip lithium niobate microdisk resonators. Opt. Express, 24(19):21869–21879, 2016. doi: 10.1364/OE.24.021869.DOI
  25. [25]Jiankun Hou, Boyi Xue, Ruixin Ma, Simin Yu, Yicheng Zhu, Xianfeng Chen, Juanjuan Lu, and Wenjie Wan. UV-enhanced photorefractive response rate in a thin-film lithium niobate microdisk. Opt. Lett., 49(12):3456–3459, 2024. doi: 10.1364/OL.527579.
  26. [26]Xinyi Ren, Chun-Ho Lee, Kaiwen Xue, Shaoyuan Ou, Yue Yu, Zaijun Chen, and Mengjie Yu. Photorefractive and pyroelectric photonic memory and long-term stability in thin-film lithium niobate microresonators. npj Nanophotonics, 2(1):1, 2025. doi: 10.1038/s44310-024-00052-3.DOI
  27. [27]C. F. J. Wu. Jackknife, bootstrap and other resampling methods in regression analysis. Ann. Statist., 14(4):1261–1295, 1986. doi: 10.1214/aos/1176350142.DOI
  28. [28]A. Colin Cameron, Jonah B. Gelbach, and Douglas L. Miller. Bootstrap-based improvements for inference with clustered errors. Rev. Econ. Stat., 90(3):414–427, 2008. doi: 10.1162/rest.90.3.414.DOI

Paper details

vlnc:W_gxtmsas7
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Generative AI tools

View statement
Looking for related papers…
Contents