Real-time analog circuit for auto-correlative weak-value amplification in the time domain

Abstract

The auto-correlative weak-value amplification (AWVA) technique demonstrates distinct advantages over standard weak-value amplification (SWVA) for quantum parameter estimation. To achieve enhanced precision in real-time parameter estimation, the AWVA requires additional resources compared to SWVA, namely real-time multiplication and integrator modules. We implemented a real-time analog circuit for AWVA using an AD835 multiplier and an NE5532 operational amplifier for the integrator. The circuit was tested using Gaussian pointers in the AWVA scheme, exhibiting sufficient sensitivity for Gaussian pointers with frequencies 200 Hz < f < 20kHz. Compared to SWVA, AWVA achieves higher accuracy and superior robustness against noise at signal-to-noise ratios (SNRs) of -12 dB < SNR < -4 dB. Beyond quantum metrology, the circuit is applicable to diverse detection schemes for correlated signals.

Introduction

The implementation of rapid, sensitive, quantitative, low-cost, and real-time parameter estimation and feedback control has garnered significant interest across laboratory-based systems and various fields.[1, 2] Such processing can be achieved using either traditional analog circuits or digital circuits such as field programmable gate arrays (FPGAs). Analog electronic feedback loops have demonstrated particular utility in quantum control applications, notably for stabilizing mechanical quantum systems.[1] Similar techniques have been implemented in large-scale instrumentation such as the AURIGA gravitational wave detector.[3] Meanwhile, custom FPGA systems are increasingly prevalent in sensing and quantum information applications,[1, 4] offering superior computational capabilities and noise immunity. Nevertheless, analog circuits retain relevance due to their low latency, cost-effectiveness, and efficiency for fundamental operations.

Weak measurements have established a robust framework for quantum metrology and information processing.[5, 6, 7, 8, 9, 10, 11, 12] Recent advances include implementations within double-slit interferometers that enhance both sensitivity and signal-to-noise ratio,[13] alongside ongoing refinements of weak measurement techniques.[14, 15, 16, 17] Our group has introduced auto-correlative weak-value amplification (AWVA) to enhance estimation precision under conditions of strong Gaussian white noise.[17] This technique extends standard weak-value amplification (SWVA)[5] by implementing two simultaneous auto-correlative weak measurements to obtain the auto-correlation intensity Θ\Theta. While our initial Simulink simulations[17] demonstrated the approach using discrete signal processing, they revealed a critical dependence of precision on sampling frequency. Higher sampling frequencies improve precision at the cost of increased computational demands. Consequently, practical AWVA implementation requires either analog circuits or optimized digital systems capable of real-time auto-correlation computation.

Here, we develop a real-time analog circuit implementing the product and integrator operations essential to AWVA. Our design employs an AD835 four-quadrant multiplier, NE5532 dual low-noise operational amplifiers, and an oscilloscope for readout. We characterize the circuit by: (1) identifying individual component performance; (2) comparing measured auto-correlation intensities Θ(t)\Theta(t) against theoretical predictions for various input signals; and (3) benchmarking AWVA against SWVA under controlled noise amplitudes. Our results demonstrate the circuit’s viability for AWVA applications, exhibiting significant noise robustness.

Further author information: Jing-Hui Huang: E-mail: [email protected]; Xiang-Yun Hu: E-mail: [email protected].

Auto-correlative weak-value amplification

As shown in Figure 1(A), we present the AWVA scheme in the time domain. AWVA includes one SWVA and another projective measurement without weak coupling. In SWM, we prepare the initial state of a two-level system as the polarization state ∣Φi⟩=(∣H⟩+∣V⟩)/2|\Phi_i\rangle= (|H\rangle+ |V\rangle)/\sqrt{2}, while the pointer state is prepared in the position basis ∣Ψi⟩=∫dqf(q)∣q⟩|\Psi_i\rangle= \int dq f(q)|q\rangle. Here q^\hat{q} denotes the longitudinal position along the light’s propagation direction in a co-moving frame, with ∣H⟩|H\rangle and ∣V⟩|V\rangle representing horizontal and vertical polarization states, respectively. The observable operator is A^=∣H⟩⟨H∣−∣V⟩⟨V∣\hat{A} = |H\rangle\langle H| - |V\rangle\langle V|, yielding the joint input state: ∣Φi⟩⊗∣Ψi⟩=12(∣H⟩+∣V⟩)∫dqf(q)∣q⟩|\Phi_i\rangle\otimes|\Psi_i\rangle= \frac{1}{\sqrt{2}}(|H\rangle+ |V\rangle)\int dqf(q)|q\rangle.

Schematic diagram of the system

Figure 1. Schematic diagram of the system. (A) The AWVA measurement. (B) An alternative plan for generating autocorrelated signals. (C) Multiplier diagram with the AD835 chip. (D) Integrator diagram with the NE5532 chip.

The system and pointer undergo weak coupling described by the von Neumann Hamiltonian:[17] H^=g(t)A^⊗p^\hat{H} = g(t)\hat{A}\otimes\hat{p}, where p^\hat{p} is the momentum operator conjugate to q^\hat{q} (corresponding to optical frequency in the time/position domain), and g(t)g(t) is the instantaneous coupling rate. Solving the time-dependent Schrödinger equation yields the unitary evolution operator: U^=exp⁡(−i∫titfH^dt)=exp⁡(−iγA^⊗p^)\hat{U} = \exp\left(-i\int_{t_i}^{t_f}\hat{H}dt\right) = \exp(-i\gamma\hat{A}\otimes\hat{p}), where γ=∫titfg(t)dt\gamma= \int_{t_i}^{t_f}g(t)dt defines the coupling strength. Following established WVA protocols,[14, 15, 16] we use time-delay estimation as our benchmark application, where τ≡γ\tau\equiv\gamma represents the unknown parameter. While such small temporal shifts (τ\tau) typically evade direct projective measurement, post-selected weak measurements enable their precise estimation. To extract τ\tau from temporal pointer displacements, we post-select the system state as: ∣Φf⟩=sin⁡(−π4+α)∣H⟩+cos⁡(−π4+α)∣V⟩|\Phi_f\rangle= \sin\left(-\frac{\pi}{4}+\alpha\right)|H\rangle+\cos\left(-\frac{\pi}{4}+\alpha\right)|V\rangle, with a projective operator denoted as B^=∣H⟩⟨H∣−∣V⟩⟨V∣\hat{B} = |H\rangle\langle H| - |V\rangle\langle V|. One then obtains the weak value as: Aw:=⟨Φf∣A^∣Φi⟩⟨Φf∣Φi⟩=−cot⁡αA_w := \frac{\langle\Phi_f|\hat{A}|\Phi_i\rangle}{\langle\Phi_f|\Phi_i\rangle}=-\cot\alpha. Then, the final state of the pointer can be obtained: ∣Ψf⟩=⟨Φf∣e−iτA^⊗p^∣Ψi⟩∣Φi⟩≈⟨Φf∣Φi⟩e−iτAwp^∣Ψi⟩|\Psi_f\rangle= \langle\Phi_f|e^{-i\tau\hat{A}\otimes\hat{p}}|\Psi_i\rangle|\Phi_i\rangle\approx\langle\Phi_f|\Phi_i\rangle e^{-i\tau A_w\hat{p}}|\Psi_i\rangle. Normally, the profile of the initial pointer is chosen as the Gaussian profile: ∣⟨t∣Ψi⟩∣2=I0(2πω2)1/4e−(t−t0)2/4ω2|\langle t|\Psi_i\rangle|^2 = \frac{I_0}{(2\pi\omega^2)^{1/4}}e^{-(t-t_0)^2/4\omega^2}. Where I0I_0 represents the normalization factor and ω\omega represents the pointer spread. Finally, the signal I1(t)I_1(t) of the SWVA detected by an APD is given by:

I1(t;τ)=∣⟨Φf∣Φi⟩∣2e−2iτAwp^∣⟨t∣Ψi⟩∣2≈I02(sin⁡α)2(2πω2)1/4e−(t−t0−δt)2/4ω2.(1)I_1(t;\tau)=|\langle\Phi_f|\Phi_i\rangle|^2e^{-2i\tau A_w\hat{p}}|\langle t|\Psi_i\rangle|^2\approx\frac{I_0}{2}\frac{(\sin\alpha)^2}{(2\pi\omega^2)^{1/4}}e^{-(t-t_0-\delta t)^2/4\omega^2}. \tag*{(1)}

Eq. (1) indicates that the time shift τ\tau can be amplified and obtained from the shift δt=∣τRe⁡[Aw]∣=τcot⁡α\delta t=|\tau\operatorname{Re}[A_w]|=\tau\cot\alpha of the pointer. At the same time, the signal I2(t;τ)I_2(t;\tau) corresponds to the results of the projective measurement without weak coupling (U^\hat{U}) is given by:

I2(t;τ)=∣⟨Φf∣Φi⟩∣2∣⟨t∣Ψi⟩∣2≈I02(sin⁡α)2(2πω2)1/4e−(t−t0)2/4ω2.(2)I_2(t;\tau)=|\langle\Phi_f|\Phi_i\rangle|^2|\langle t|\Psi_i\rangle|^2\approx\frac{I_0}{2}\frac{(\sin\alpha)^2}{(2\pi\omega^2)^{1/4}}e^{-(t-t_0)^2/4\omega^2}. \tag*{(2)}

In our previous work,[17] our simulation has demonstrated that the measurement of the new quantity, namely the auto-correlation intensity Θ(t)\Theta(t) outperforms the direct measurement of the pointer shift I1(t;τ)I_1(t;\tau) with smaller statistical errors under strong Gaussian white noise background. Θ(t)\Theta(t) is calculated by:

Θ(t;τ)=∫0tI1(t′;τ)×I2(t′) dt′=I024(sin⁡α)4(2πω2)1/8∫0te−[(t−t0)2+(t′−t0−δt)2]/4ω2 dt′(3)\Theta(t;\tau)=\int_0^t I_1(t';\tau)\times I_2(t')\,\mathrm{d}t'=\frac{I_0^2}{4}\frac{(\sin\alpha)^4}{(2\pi\omega^2)^{1/8}}\int_0^t e^{-[(t-t_0)^2+(t'-t_0-\delta t)^2]/4\omega^2}\,\mathrm{d}t' \tag*{(3)}

Experimental results and Discussion

The experimental setup is shown in Figure 1 and Figure 1(B) of the Supplemental Material[18]. Key components include: A function/arbitrary waveform generator (RIGOL DG4202, 200 MHz, 500 MSa/s) for signal generation; A digital oscilloscope (Agilent DSO7052B, 500 MHz, 4 GSa/s) for signal acquisition and analysis. The time delay τ\tau (the estimation parameter in AWVA) manifests as a temporal shift δt\delta t in the pointer. We implement δt\delta t by phase-shifting one input signal using the generator. This approach substitutes the full AWVA measurement process (Figure 1A) with direct generation of the weak-value-modified signal I1(t;τ)I_1(t;\tau) and reference signal I2(t)I_2(t) (Figure 1B). The signal Θ(t)\Theta(t) is then computed in real-time by the analog circuit and displayed on the oscilloscope.

Before AWVA implementation, we characterized the multiplier and integrator circuits individually (see Supplemental Material Sec. II and Sec. III). These measurements yield the overall gain coefficient Γ=ΓM×ΓI\Gamma=\Gamma_M\times\Gamma_I. For Gaussian pointers, we obtain Γga=ΓMga×ΓIga=1.87×4470=8358\Gamma^{\mathrm{ga}}=\Gamma_M^{\mathrm{ga}}\times\Gamma_I^{\mathrm{ga}}=1.87\times4470=8358, representing significant signal amplification relative to theoretical predictions. This gain enhancement is particularly valuable since post-selection in AWVA reduces the success probability.[19] Noise characterization (Supplemental Material Sec. IV) confirms minimal Gaussian noise impact on AWVA performance for pointer frequencies of 200 Hz and 2000 Hz.

We next quantify Θ(t)\Theta(t) for the Gaussian pointer in noise-free conditions. The input signals are defined as:

I1G(t)=0.248exp⁡[−2(t−1.71×10−43.88×10−4)2]−0.01,I2G(t)=0.248exp⁡[−2(t−1.71×10−4−δt3.88×10−4)2]−0.01(4)I_1^G(t)=0.248\exp\left[-2\left(\frac{t-1.71\times10^{-4}}{3.88\times10^{-4}}\right)^2\right]-0.01,\quad I_2^G(t)=0.248\exp\left[-2\left(\frac{t-1.71\times10^{-4}-\delta t}{3.88\times10^{-4}}\right)^2\right]-0.01 \tag*{(4)}

with δt\delta t representing the temporal shift between signals. Figure 2 compares these inputs with the theoretical auto-correlation Θt(t;t0)\Theta^t(t;t_0) at δt=0\delta t=0. Figure 2(B) shows excellent agreement between scaled theory (8358Θt(t))(8358\Theta^t(t)) and phase-corrected experiment (−Θ(t+75μs))(-\Theta(t+75\mu\mathrm{s})). The 75μs75\mu\mathrm{s} phase lag originates from circuit capacitance and was determined by curve alignment. The curves coincide within −0.2≤t≤0.1-0.2\le t\le0.1 ms (half-cycle duration), validating our circuit implementation. In this paper, the phase lag tϕt_\phi does not affect sensitivity KK, defined as:

Input signals and theoretical and experimental auto-correlation

Figure 2. (A) The input of signals I1G(t)I_1^G(t) and I2G(t;δt=0us)I_2^G(t;\delta t=0\mathrm{us}). (B) The theoretical Θt(t)\Theta^t(t) and the experimental Θ(t)\Theta(t).

K=−Θ(t+tϕ;δt)−Θ(t+tϕ)δt=−Θ(t;δt)−Θ(t)δt(5)K=-\frac{\Theta(t+t_\phi;\delta t)-\Theta(t+t_\phi)}{\delta t}=-\frac{\Theta(t;\delta t)-\Theta(t)}{\delta t} \tag*{(5)}

Figure 3 of the Supplemental Material shows single Θ(t;δt)\Theta(t;\delta t) measurements for different time shifts δt\delta t in signals I1G(t)I_1^G(t) and I2G(t)I_2^G(t) at various frequencies ff. The Θ(t;δt)\Theta(t;\delta t) profile exhibits significant frequency dependence. Table 1 summarizes sensitivity measurements across frequencies, where maximum values Max⁡[Θ(t;δt)]\operatorname{Max}[\Theta(t;\delta t)] and Max⁡[Θ(t)]\operatorname{Max}[\Theta(t)] were directly recorded from oscilloscope amplitudes with associated standard deviations. Key observations from Table 1 include: (i) Sensitivity KK increases while its standard error decreases with larger δt\delta t, demonstrating enhanced precision for greater time shifts. (ii) Higher frequencies ff increase sensitivity (and thus precision) at the cost of reduced Θ(t)\Theta(t) amplitude, limited by the NE5532’s performance. (iii) Oscilloscope measurements yield stable mean values for Max⁡[Θ(t;δt)]\operatorname{Max}[\Theta(t;\delta t)] and Max⁡[Θ(t)]\operatorname{Max}[\Theta(t)] at C>10,000C>10,000, validating mean KK as a reliable metric despite its standard error.

ffδt\delta tMax⁡[Θ(t)]\operatorname{Max}[\Theta(t)]Max⁡[Θ(t;δt)]\operatorname{Max}[\Theta(t;\delta t)]KK
2005076.797 ±\pm 0.83975.978 ±\pm 0.8471.638 ±\pm 3.372
20010076.797 ±\pm 0.83972.278 ±\pm 0.8794.519 ±\pm 1.718
2000528.732 ±\pm 0.21928.273 ±\pm 0.2419.180 ±\pm 9.200
20001028.732 ±\pm 0.21926.837 ±\pm 0.17818.950 ±\pm 3.970
200000.56.8856 ±\pm 0.1206.8087 ±\pm 0.13515.380 ±\pm 50.10
200001.06.8856 ±\pm 0.1206.4790 ±\pm 0.11340.660 ±\pm 23.33

Table 1. Characteristic results for measuring δt\delta t (us) with different frequency ff (Hz). The maximum values Max⁡[Θ(t;δt)]\operatorname{Max}[\Theta(t;\delta t)] (mV) and Max⁡[Θ(t)]\operatorname{Max}[\Theta(t)] (mV) are directly read out as the amplitude with their standard deviation from the scope. The unite of KK is 10−210^{-2} mV/us.

AWVA measurements under strong Gaussian noise

Figure 3. AWVA measurements under strong Gaussian noise. (A, C) Input signals I1N(t)I_1^N(t) (solid) and I2N(t;δt=50μs)I_2^N(t;\delta t=50\mu\mathrm{s}) (dashed) at noise amplitudes (A) NA=500N_A=500 mV and (C) NA=1000N_A=1000 mV. (B, D) Corresponding auto-correlation outputs −Θ(t)-\Theta(t) showing (B) 500 mV and (D) 1000 mV noise responses.

Finally, we characterize AWVA performance under strong Gaussian noise by injecting noise N(t,NA)\mathbf{N}(t,N_A) into the pointer signals. The resulting auto-correlation intensity ΘIN(t;δt)\Theta_{\mathrm{IN}}(t;\delta t) is defined as:

ΘIN(t;δt)=∫0t[I1G(t′;δt)+N(t′,NA)]×[I2G(t′)+N(t′,NA)]dt′,(6)\Theta_{\mathrm{IN}}(t;\delta t)=\int_{0}^{t}\left[I_1^G(t';\delta t)+\mathbf{N}(t',N_A)\right]\times\left[I_2^G(t')+\mathbf{N}(t',N_A)\right]\mathrm{d}t', \tag*{(6)}

where the pointer amplitude is fixed at 250 mV and the noise amplitude NAN_A ranges from 0 to 2000 mV. Figure 3 shows representative single-shot measurements, while statistical results (mean and standard deviation over >104>10^4 trials) are tabulated in Table 1 of the Supplemental Material. To quantify noise robustness, we compute normalized sensitivities for both techniques:

KW=δtScopeδt=δtScope50μs,KA=K(NA)K(NA=0mV)=K(NA)1.208×10−2mV/μs,(7)K^W=\frac{\delta t^{\mathrm{Scope}}}{\delta t}=\frac{\delta t^{\mathrm{Scope}}}{50\mu\mathrm{s}},\qquad K^A=\frac{K(N_A)}{K(N_A=0\mathrm{mV})}=\frac{K(N_A)}{1.208\times10^{-2}\mathrm{mV}/\mu\mathrm{s}}, \tag*{(7)}

where δtScope\delta t^{\mathrm{Scope}} is the time delay measured by the scope. Following [17] we define the signal-to-noise ratio as:

SNR=20log⁡10(max⁡∣I1out(t)∣max⁡∣N(t)∣).(8)\mathrm{SNR}=20\log_{10}\left(\frac{\max\lvert I_1^{\mathrm{out}}(t)\rvert}{\max\lvert N(t)\rvert}\right). \tag*{(8)}

Comparing SWVA and AWVA performance reveals key insights: (i) Low-noise regime (00 mV ≤NA≤100\leq N_A \leq100 mV, SNR >8> 8 dB): SWVA exhibits smaller error bars than AWVA, demonstrating no AWVA advantage under low-noise conditions. (ii) Moderate-noise regime (400400 mV ≤NA≤1000\leq N_A \leq1000 mV, −12-12 dB ≤\leq SNR ≤−4\leq-4 dB): AWVA achieves superior performance with reduced mean-value deviation and smaller error bars in KAK^A compared to KWK^W (Table 2, Figure 4B). (iii) High-noise regime (12001200 mV ≤NA≤2000\leq N_A \leq2000 mV, −18-18 dB ≤\leq SNR ≤−13\leq-13 dB): While AWVA shows larger KAK^A error bars than SWVA’s KWK^W, it maintains smaller mean-value deviation. Crucially, SWVA yields invalid negative sensitivities at 1400/1800/2000 mV, while AWVA preserves valid positive values. (iv) Noise-scaling effects: Increasing NAN_A amplifies both ΘIN\Theta_{\mathrm{IN}} amplitude and KAK^A statistical error. This error stems from circuit noise response (Supplemental Material Sec. IV) and represents a systematic component addressable through increased bandwidth. (v) Robustness to unknown noise: For background noise 2≤NA≤20002 \leq N_A \leq2000 mV, KWK^W varies over [−1.86,2.24][-1.86, 2.24] (encompassing invalid values), while KAK^A remains within [0.80,1.72][0.80, 1.72]. AWVA thus demonstrates superior robustness against unknown noise amplitudes.

NAN_AKSK^SKAK^ANAN_AKSK^SKAK^A
21.00±0.091.00 \pm0.091.00±0.481.00 \pm0.482001.04±0.461.04 \pm0.461.04±0.941.04 \pm0.94
101.02±0.041.02 \pm0.040.95±0.510.95 \pm0.513000.88±0.940.88 \pm0.940.98±1.250.98 \pm1.25
201.02±0.071.02 \pm0.070.94±0.590.94 \pm0.594000.66±2.900.66 \pm2.901.05±1.441.05 \pm1.44
301.04±0.081.04 \pm0.081.01±0.711.01 \pm0.715002.02±10.92.02 \pm10.91.11±1.801.11 \pm1.80
401.00±0.091.00 \pm0.090.93±0.620.93 \pm0.626002.24±12.12.24 \pm12.11.32±1.891.32 \pm1.89
501.04±0.131.04 \pm0.130.94±0.580.94 \pm0.587004.10±13.44.10 \pm13.41.22±2.241.22 \pm2.24
600.98±0.140.98 \pm0.140.90±0.530.90 \pm0.538000.60±9.400.60 \pm9.401.30±2.551.30 \pm2.55
701.06±0.221.06 \pm0.220.80±0.620.80 \pm0.629000.32±8.000.32 \pm8.000.91±2.910.91 \pm2.91
801.20±0.281.20 \pm0.281.00±0.611.00 \pm0.6110000.46±6.280.46 \pm6.281.72±3.521.72 \pm3.52
901.24±0.301.24 \pm0.300.85±0.650.85 \pm0.6512000.12±5.760.12 \pm5.761.46±5.701.46 \pm5.70
1000.90±0.440.90 \pm0.441.04±0.701.04 \pm0.701400−0.50±6.90-0.50 \pm6.901.49±8.181.49 \pm8.18
16000.36±5.460.36 \pm5.461.21±11.91.21 \pm11.9
1800−1.86±7.68-1.86 \pm7.681.21±18.31.21 \pm18.3
2000−1.22±7.38-1.22 \pm7.381.12±26.61.12 \pm26.6

Table 2. The normalized sensitivities KSK^S in SWVA and KAK^A in AWVA for measuring δt=50\delta t = 50 us at frequency f=200f = 200 Hz under Gaussian noises with different amplitude NAN_A (mV).

Sensitivities versus noise amplitude for SWVA and AWVA

Figure 4. Sensitivities KWK^W (SWVA) and KAK^A (AWVA) versus noise amplitude for δt=50μ\delta t = 50\mus time shifts. The green band highlights the 400–1000 mV range where AWVA achieves smaller error bars than SWVA.

Conclusions

In summary, we implemented a real-time analog circuit for auto-correlative weak-value amplification (AWVA) using an AD835 multiplier and NE5532-based integrator. Our hardware-focused approach enables direct computation of the auto-correlation integral. Key findings include: (i) The NE5532 amplifier provides significant signal gain (up to 8358× for Gaussian pointers), compensating for AWVA’s post-selection losses. (ii) Experimental validation confirms AWVA’s advantage over standard weak-value amplification (SWVA) under moderate-to-high noise (200 mV ≤NA≤2000\leq N_A \leq2000 mV). (iii) The circuit architecture extends beyond quantum metrology to general auto-correlation signal processing. These results establish a hardware pathway for noise-resilient parameter estimation in real-time sensing applications.

Acknowledgments

This study was supported by the National Natural Science Foundation of China (Grants No. 42327803 and No. 42488201). J-H. Huang acknowledges support from the Hubei Provincial Natural Science Foundation of China (Grant No. 20250650025), the Postdoctoral Fellowship Program and China Postdoctoral Science Foundation under Grant Number BX20250161.

References

  1. [1]Rossi, M., Mason, D., Chen, J., Tsaturyan, Y., and Schliesser, A., “Measurement-based quantum control of mechanical motion,” Nature 563(7729), 53–58 (2018).DOI
  2. [2]Hoshi, I., Shimobaba, T., Kakue, T., and Ito, T., “Real-time single-pixel imaging using a system on a chip field-programmable gate array,” Scientific Reports 12(1), 14097 (2022).DOI
  3. [3]Vinante, A., Bignotto, M., Bonaldi, M., Cerdonio, M., Conti, L., Falferi, P., Liguori, N., Longo, S., Mezzena, R., Ortolan, A., Prodi, G. A., Salemi, F., Taffarello, L., Vedovato, G., Vitale, S., and Zendri, J.-P., “Feedback cooling of the normal modes of a massive electromechanical system to submillikelvin temperature,” Phys. Rev. Lett. 101, 033601 (Jul 2008).DOI
  4. [4]Philips, S. G. J., Mądzik, M. T., Amitonov, S. V., de Snoo, S. L., Russ, M., Kalhor, N., Volk, C., Lawrie, W. I. L., Brousse, D., Tryputen, L., Wuetz, B. P., Sammak, A., Veldhorst, M., Scappucci, G., and Vandersypen, L. M. K., “Universal control of a six-qubit quantum processor in silicon,” Nature 609(7929), 919–924 (2022).DOI
  5. [5]Aharonov, Y., Albert, D. Z., and Vaidman, L., “How the result of a measurement of a component of the spin of a spin-1/2 particle can turn out to be 100,” Phys. Rev. Lett. 60, 1351–1354 (Apr 1988).pubmed.ncbi.nlm.nih.gov/10038016
  6. [6]Dressel, J., Malik, M., Miatto, F. M., Jordan, A. N., and Boyd, R. W., “Colloquium: Understanding quantum weak values: Basics and applications,” Rev. Mod. Phys. 86, 307–316 (Mar 2014).DOI
  7. [7]Harris, J., Boyd, R. W., and Lundeen, J. S., “Weak value amplification can outperform conventional measurement in the presence of detector saturation,” Phys. Rev. Lett. 118, 070802 (Feb 2017).DOI
  8. [8]Lundeen, J. S. and Bamber, C., “Procedure for direct measurement of general quantum states using weak measurement,” Phys. Rev. Lett. 108, 070402 (Feb 2012).pubmed.ncbi.nlm.nih.gov/22401180
  9. [9]Jordan, A. N., Martínez-Rincón, J., and Howell, J. C., “Technical advantages for weak-value amplification: When less is more,” Phys. Rev. X 4, 011031 (Mar 2014).
  10. [10]Xu, L., Liu, Z., Datta, A., Knee, G. C., Lundeen, J. S., Lu, Y.-q., and Zhang, L., “Approaching quantum-limited metrology with imperfect detectors by using weak-value amplification,” Phys. Rev. Lett. 125, 080501 (Aug 2020).DOI
  11. [11]Krafczyk, C., Jordan, A. N., Goggin, M. E., and Kwiat, P. G., “Enhanced weak-value amplification via photon recycling,” Phys. Rev. Lett. 126, 220801 (Jun 2021).DOI
  12. [12]Liu, Y., Zhang, Y., Xu, Z., Zhou, L., Zou, Y., Zhang, B., and Hu, Z., “Ultra-low noise phase measurement of fiber optic sensors via weak value amplification,” Opt. Express 30, 18966–18977 (May 2022).DOI
  13. [13]Huang, J.-H., Jordan, K. M., Dada, A. C., Hu, X.-Y., and Lundeen, J. S., “Enhancing interferometry using weak value amplification with real weak values,” Phys. Rev. Lett. 134, 080802 (Feb 2025).DOI
  14. [14]Li, Z., Xie, L., Ti, Q., Duan, P., Zhang, Z., and Ren, C., “Increasing the dynamic range of weak measurement with two pointers,” Phys. Rev. A 102, 023701 (Aug 2020).DOI
  15. [15]Huang, J., Li, Y., Fang, C., Li, H., and Zeng, G., “Toward ultrahigh sensitivity in weak-value amplification,” Phys. Rev. A 100, 012109 (Jul 2019).DOI
  16. [16]Huang, J.-H., He, F.-F., Duan, X.-Y., Wang, G.-J., and Hu, X.-Y., “Modified weak-value-amplification technique for measuring a mirror’s velocity based on the vernier effect,” Phys. Rev. A 105, 013718 (Jan 2022).DOI
  17. [17]Huang, J.-H., Hu, X.-Y., Dada, A. C., Lundeen, J. S., Jordan, K. M., Chen, H., and An, J., “Autocorrelative weak-value amplification and simulating the protocol under strong gaussian noise,” Phys. Rev. A 106, 053704 (Nov 2022).DOI
  18. [18]Huang, J.-H., “Real-time analog circuit for auto-correlative weak-value amplification in the time domain: supplemental document,” (2025). https://doi.org/10.7910/DVN/EOYJHO, Harvard Dataverse,2025.
  19. [19]Ferrie, C. and Combes, J., “Weak value amplification is suboptimal for estimation and detection,” Phys. Rev. Lett. 112, 040406 (Jan 2014).pubmed.ncbi.nlm.nih.gov/24580424

Paper details

vlnc:W_gytnyxuv
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 1

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents