Study of laser-beam arrival time synchronization towards sub-picosecond stability level

Abstract

A precise synchronization between laser pulse and electron beam arrival time is essential for achieving sub-picosecond stability in modern accelerator facilities. In this work, a Low-Level RF system architecture combined with White Rabbit based timing system has been tested through a collaboration between KEK (Japan) and CNRS/IN2P3, IJClab (France). The setup combines a frequency standard generator, an IDROGEN carrier board with an embedded White Rabbit node, and SkyWorks synthesizers of different form factors to distribute phase-locked clock signals over telecommunication fiber. Phase noise power spectral density measurements were performed at several RF sub-harmonics to confirm synchronization performance. These results demonstrate the feasibility of implementing the White Rabbit-IDROGEN synchronization scheme for large-scale accelerators, including applications to laser-based diagnostics.

Introduction

The synchronicity between the laser pulse and the beam arrival time is a key requirement for laser-based diagnostics such as polarimetry [1, 2], transverse beam size measurements [3], laser-Compton X-Ray generation experiments [4, 5, 6] and beam position monitor frontend electronics [7, 8]. Therefore, maintaining a stable synchronization between the laser system, the accelerating field, and the overall accelerator timing trigger signals network is of primary importance. In most cases, a reference clock signal—typically a sub-harmonic of the main accelerating frequency—is employed to drive the laser system’s piezo feedback control. In large-scale accelerator facilities, laser-based diagnostics are often installed hundreds of meters to several kilometers away from the master Low-Level Radio Frequency (LLRF) Signal Generator (SG) [9, 10]. Conventional RF cable links are unsuitable for such distances due to their sensitivity to electromagnetic interference, temperature variation, and humidity-induced phase drift. Consequently, clock distribution via optical fiber is preferred. Three main approaches exist for optical fiber–based clock delivery. The first relies on straightforward electro-optical (E/O) and opto-electrical (O/E) conversion without active delay drift compensation [11, 12]. The second introduces feedback-based delay stabilization to mitigate environmental effects [6]. The third, increasingly adopted in modern timing systems, employs event-code transmission between a carrier master board and a local synthesizer board [13]. This last approach can be integrated into an event-based timing system architecture [14, 15, 16]. When implemented using the White Rabbit (WR) transmission protocol, it inherently provides precise delay compensation and deterministic phase alignment. In this context, the IDROGEN carrier board [17], equipped with an embedded WR node, provides a modular and scalable realization of this concept. As a result, it simplifies LLRF and timing architectures in large accelerator systems and enables low-jitter signal distribution over long distances while reducing complexity and maintenance effort.

IDROGEN carrier board and its synthesizer

The IDROGEN carrier board, developed at IJCLab, is a µTCA.4 platform based on an Altera FPGA that integrates a fully functional WR timing node [18]. It incorporates a dual-loop PLL clock-jitter cleaner and an in-FPGA Digital Dual-Mixer Time-Difference (DDMtD) phase comparator, providing deterministic and low-jitter clock distribution. The board supports FMC synthesizer mezzanines, such as those built around the SkyWorks SI 5362, enabling precise generation of RF sub-harmonics required for particle accelerator facilities LLRF systems. To confirm the applicability of the carrier board, tests were conducted at IJCLab, KEK ATF, and SuperKEKB. Building on the initial synchronization study reported in [17], a detailed jitter and long-term stability analysis was performed at RF frequencies relevant for laser-based diagnostics.

Low-level test at CNRS/IN2P3, IJCLab

The IDROGEN master configuration was characterized using the I/Q-demodulation technique [14, 17, 19, 20], and the corresponding phase-noise power spectral densities (PN-PSDs)

were measured with a Digital Noise Analyzer (DNA). The master configuration consisted of the Stanford Research Systems (SRS) FS725 frequency standard generator combined with an RF low-noise amplifier (LNA), the IDROGEN master and slave carrier boards, a SkyWorks SI5362-A-EVB synthesizer and FMC format SI 5362 synthesizer. The phase-detection and acquisition modules are I/Q demodulators with RedPitaya STEMlab 125-14 FPGA board based digitizers [19, 20] (see Figure 1(a)). Both synthesizer boards share the same SI 5362 PLL/VCO core and similar loop parameters, so the PN-PSD results obtained on the SI 5362-A-EVB board are representative for the FMC-based module. The frequency standard served as the grandmaster, distributing 10 MHz reference to synchronize the IDROGEN master-slave boards chain, the Rohde&Schwarz SML03 SG, and the DNA. Once the master was phase-locked, the WR protocol was transmitted over a 25 m optical link to the slave, ensuring deterministic synchronization of both boards. The synthesizer output phases were then aligned to the SG output ones. To evaluate the oscillator and PLL stability of the carrier boards, PN-PSD measurements were performed for KEK ATF LLRF system architecture sub-harmonics, specifically the 8th (357 MHz) and 16th (178.5 MHz) sub-harmonics of the 2.856 GHz accelerating frequency [11, 14]. The offset-frequency range spanned 1 Hz – 10 MHz (see Figure 1(b)).

Image not extracted

Figure 1. The synchronization performance measurement setup: (a) is the block diagram, (b) is the signals PN-PSDs

Long-term phase stability was also evaluated for 357 MHz signal over a 12-hour period to assess suitability as a local-oscillator (LO) source for accelerator facilities LLRF systems. The SkyWorks SI 5362-A-EVB and FMC-based synthesizer demonstrated 3∘3^\circ (pp) and 4∘4^\circ (pp) relative phase jitter with respect to the SML03 SG, respectively. The I/Q demodulation technique allows phase measurements with 0.1∘0.1^\circ precision [21]. Figure 2(a)–(Figure 2b) show periodic phase fluctuations with approximately 30 min cycles and 1∘1^\circ amplitude, superimposed on the slower drift. For the SI 5362-A-EVB vs FMC comparison (see Figure 2(c)), the phase-jitter component clearly dominates over the slow fluctuation, confirming good short-term coherence between synthesizers.

Image not extracted

Figure 2. The phase stability measurement results: (a) is the SkyWorks SI 5362-A-EVB synthesizer relative Rohde&Schwarz SML03 SG phase drift vs time, (b) is the SkyWorks SI 5362 FMC synthesizer relative Rohde&Schwarz SML03 SG phase drift vs time, (c) is the SkyWorks SI 5362-A-EVB synthesizer relative the SkyWorks SI 5362 FMC synthesizer phase drift vs time

The PN-PSD spectra (see Figure 1(b)) confirm ps-level phase stability of the IDROGEN–SkyWorks synthesizers chain under laboratory condition. For the 178.5 MHz signal, the phase-noise levels reached −80 dBc/Hz, −110 dBc/Hz, and −140 dBc/Hz at 100 Hz, 1 kHz, and 10 kHz offset, respectively. At 357 MHz, the PN-PSD is approximately 6 dB higher across the spectrum, consistent with the 6 dB theoretical scaling of phase noise with doubled carrier frequency. The IDROGEN slave-board output at 125 MHz reproduced

SignalFrequencyIntegration rangeRMS jitter2RMS jitter3
SRS FS72510 MHz1 Hz – 5 MHz0.44 ps0.44 ps
10 Hz – 5 MHz0.39 ps0.39 ps
IDROGEN Master carrier board125 MHz1 Hz – 10 MHz0.54 ps0.54 ps
10 Hz – 10 MHz0.49 ps0.49 ps
IDROGEN Slave carrier board125 MHz1 Hz – 10 MHz1.29 ps1.29 ps
10 Hz – 10 MHz0.91 ps0.91 ps
SkyWorks SI 5362-A-EVB178.5 MHz1 Hz – 10 MHz1.44 ps1.44 ps
10 Hz – 10 MHz0.85 ps0.85 ps
SkyWorks SI 5362 FMC178.5 MHz1 Hz – 10 MHz1 Hz – 10 MHz1.54 ps1.41 ps
10 Hz – 10 MHz0.86 ps0.86 ps
SkyWorks SI 5362-A-EVB357 MHz1 Hz – 10 MHz1.49 ps1.49 ps
10 Hz – 10 MHz0.87 ps0.87 ps
SkyWorks SI 5362 FMC357 MHz1 Hz – 10 MHz1.54 ps1.54 ps
10 Hz – 10 MHz0.87 ps0.87 ps
Rohde&Schwarz SML03 SG178.5 MHz1 Hz – 10 MHz1.83 ps1.83 ps
10 Hz – 10 MHz1.18 ps1.18 ps
Rohde&Schwarz SML03 SG357 MHz1 Hz – 10 MHz1.82 ps1.82 ps
10 Hz – 10 MHz1.21 ps1.21 ps

Table 1. RMS timing jitter of the signals

the master-board noise up to 1 kHz offset, after which its phase noise followed the internal PLL behavior of the master. Overall, the measured spectral hierarchy—from the SRS FS725 reference to the IDROGEN carrier and finally to the FMC and SkyWorks synthesizer outputs—shows that the system’s performance is primarily limited by the quality of the 10 MHz reference signal and by the phase-locked-loop (PLL) parameters of the IDROGEN master board. For reference, the SRS FS725 10 MHz output itself exhibits −100 dBc/Hz at 1 Hz, −140 dBc/Hz at 10 Hz, −150 dBc/Hz at 100 Hz, and −160 dBc/Hz at 1 kHz, establishing the baseline used for all PN-PSD normalization. Integrating the measured spectra yields timing jitter below 1 ps rms (10 Hz–10 MHz), confirming that the WR-disciplined IDROGEN system can deliver the sub-picosecond stability required for laser-to-beam synchronization at modern accelerator facilities. Spurious narrowband spikes in the PN PSD were removed using a median-filter-based despiking algorithm. These laboratory measurements established the baseline performance of the IDROGEN carrier board with the SkyWorks SI 5362 synthesizer chain. To verify its applicability in a realistic accelerator environment, the system next tests were conducted at the KEK ATF LLRF and SuperKEKB setups.

Low-level test at KEK ATF

The second test was conducted at the KEK ATF LLRF system [11] to confirm the IDROGEN carrier board applicability for the International Linear Collider beam instrumentation R&D program. The SRS FS725 reference outputs were injected into the Agilent E8663B master SG and the IDROGEN master board (see Figure 3(a)). Then, the IDROGEN master and slave

Image not extracted

Figure 3. The synchronization performance measurement setup: (a) is the block diagram, (b) is the signals PN-PSDs

boards output signals were aligned with respect to the input 10 MHz. As a result, the Agilent E8663B master SG and synthesizer connected to the IDROGEN slave board were synchronized with each other. The SkyWorks SI 5362-A-EVB synthesizer board output signal

frequency was 178.5 MHz, which is the KEK ATF RF-Gun laser oscillator pulses repetition rate. The PN-PSDs associated with the signals are shown on the Figure 3(b). It has to be mentioned that the frequency modulation of the SG was turned off [11]. The Agilent E8663B SG output is 1428 MHz. On the next stage, the signal was injected into the multichannel frequency divider&multiplier module. There are 4 output signals from the module. These are 178.5 MHz, 357 MHz, 714 MHz and 2856 MHz [11, 14]. The PN-PSD data was analyzed for 2 cases. The first one takes the PN-PSD spikes (see Figure 3(b)) contribution into account, while the second case does not include it. As can be seen on the Figure 3(b), the IDROGEN master board PN-PSD has several spikes located between 50 Hz and 3 kHz. These increase IDROGEN master carrier board RMS jitter value from 0.77 ps to 2.31 ps. However, the SkyWorks SI 5362 FMC synthesizer PN-PSD spikes do not affect the RMS jitter (see Table 2).

SignalFrequencyIntegration rangeRMS jitteraRMS jitterb
SRS FS72510 MHz1 Hz – 5 MHz0.44 ps0.44 ps
10 Hz – 5 MHz0.39 ps0.39 ps
IDROGEN Master carrier board100 MHz1 Hz – 10 MHz2.31 ps0.77 ps
10 Hz – 10 MHz2.31 ps0.76 ps
IDROGEN Slave carrier board250 MHz1 Hz – 10 MHz1.13 ps1.12 ps
10 Hz – 10 MHz0.91 ps0.89 ps
SkyWorks SI 5362 FMC178.5 MHz1 Hz – 10 MHz1.50 ps1.49 ps
10 Hz – 10 MHz0.89 ps0.88 ps
SkyWorks SI 5362 FMC357 MHz1 Hz – 10 MHz1.43 ps1.42 ps
10 Hz – 10 MHz0.88 ps0.87 ps

Table 2. RMS timing jitter of the signals

Low-level test at SuperKEKB

The synchronization test of the IDROGEN carrier board within an accelerator LLRF system was conducted at SuperKEKB [22]. The first IDROGEN board was configured as the master, while the second operated as the slave (see Figure 4(a)). In the SuperKEKB LLRF system, an Agilent E8663D signal generator produced a 510 MHz sine-wave that was frequency-divided by 51 to generate a 10 MHz reference for the entire system, including the IDROGEN boards. As a result, the 510 MHz generator acted as the grandmaster reference. The second Agilent E8663D generated the 508.9 MHz signal used by the HER and LER LLRF branches. At the

Image not extracted

Figure 4. The synchronization performance measurement setup: (a) is the block diagram, (b) is the signals PN-PSDs

next stage, a SkyWorks SI 5362 FMC synthesizer generated a 508.9 MHz clock synchronized with the HER/LER SG output [22, 23]. Both signals were fed into the phase meter module based on the I/Q demodulation to record long-term synchronization-stability data. In this configuration, the IDROGEN master board disciplined the slave board through the WR protocol, while the SkyWorks synthesizers derived their reference from the slave carrier board output. The long-term synchronization stability was measured for 12 hours (see Figure 5). The SkyWorks SI 5362 FMC-based synthesizer demonstrates 4∘4^\circ (pp) and 0.61∘0.61^\circ (RMS) phase stability with respect to the HER/LER SG LLRF branch over 12 hours. In terms of synchronization stability, these values are equal to the 21.8 ps (pp) and 3.3 ps (RMS). The long-term phase stability was therefore evaluated on this FMC implementation, while the PN-PSD corresponds to the SI 5362-A-EVB evaluation board. The PN PSDs were measured by an Agilent E5052B Signal Source Analyzer (SSA). The SSA measurement settings were 16 averages and 2 correlations. The SuperKEKB LLRF 10 MHz reference exhibited phase-noise levels of approximately −110 dBc/Hz, −130 dBc/Hz, and −140 dBc/Hz at 1 Hz, 10 Hz, and 100 Hz offset, respectively (see Figure 4(b)). Beyond 100 Hz, the phase-noise level gradually decreased from −140 dBc/Hz to −150 dBc/Hz at 1 MHz. The IDROGEN boards operating

Image not extracted

Figure 5. The phase stability measurement results

at 100 MHz and 250 MHz displayed phase-noise behavior consistent with the measurements reported in Section 2.1 and 2.2. Meanwhile, the Agilent E8663D signal generators delivering 510 MHz and 508.9 MHz outputs demonstrated outstanding phase-noise performance, reaching −80 dBc/Hz, −100 dBc/Hz, and −105 dBc/Hz at 1 Hz, 10 Hz, and 100 Hz offset, respectively. Moreover, enabling frequency modulation on the 510 MHz grandmaster SG did not degrade the phase-noise level or the HER/LER SG output synchronization quality with the SkyWorks SI 5362-A-EVB synthesizer [23]. In general, the PN-PSD spikes do not signif-

SignalFrequencyIntegration rangeRMS jittera^{a}RMS jitterb^{b}
SuperKEKB SGs reference10 MHz1 Hz – 5 MHz0.75 ps0.73 ps
10 Hz – 5 MHz0.75 ps0.73 ps
IDROGEN Master carrier board100 MHz1 Hz – 10 MHz1.11 ps0.65 ps
10 Hz – 10 MHz1.06 ps0.56 ps
IDROGEN Slave carrier board250 MHz1 Hz – 10 MHz1.26 ps1.25 ps
10 Hz – 10 MHz0.92 ps0.90 ps
SkyWorks SI 5362-A-EVB508.9 MHz1 Hz – 10 MHz2.07 ps2.07 ps
10 Hz – 10 MHz0.94 ps0.94 ps
Agilent E8663D Slave SG508.9 MHz1 Hz – 10 MHz0.11 ps0.09 ps
10 Hz – 10 MHz0.10 ps0.09 ps
Agilent E8663D Master SG510 MHz1 Hz – 10 MHz0.08 ps0.07 ps
10 Hz – 10 MHz0.05 ps0.04 ps

Table 3. RMS timing jitter of the signals

a^{a} the PN-PSD spikes contribution is taken into account

b^{b} the PN-PSD spikes contribution is not taken into account

icantly contribute to the signals RMS noise, except the IDROGEN master carrier board one. Its RMS noise with spikes contribution is equal to 1.11 ps and 1.06 ps for 1 Hz to 10 MHz and 10 Hz to 10 MHz integration ranges, respectively. However, if the spikes contribution is not taken into account, the RMS noise is equal to 0.65 ps and 0.56 ps for 1 Hz to 10 MHz and 10 Hz to 10 MHz integration ranges, correspondingly.

Conclusion

In this work, the White-Rabbit–disciplined IDROGEN carrier board combined with SI 5362-based synthesizers was experimentally evaluated as a candidate synchronization platform for large-scale accelerator LLRF systems and laser-based diagnostics. Tests at IJCLab, KEK ATF and SuperKEKB show that the WR–IDROGEN chain can distribute RF reference signals 178.5, 357 and 508.9 MHz with sub-picosecond to few-picosecond rms jitter for the 10 Hz–10 MHz integration range and long-term relative phase drift of about 3∘3^\circ – 4∘4^\circ pp at 357 MHz (23.3 ps – 31.1 ps pp) and 4∘4^\circ pp (21.8 ps pp) at 508.9 MHz over 12 h. These results demonstrate that the WR-based IDROGEN scheme is a viable solution for delivering low-jitter local-oscillator signals to remote laser systems, beam diagnostics and LLRF frontend electronics, including frequency down- and up-conversion stages, in modern accelerator facilities. Future work will address operation over km-scale links, mitigation of narrowband spurs in the phase-noise spectrum, and demonstration of closed-loop laser-to-beam arrival-time stabilization for applications such as Compton polarimetry and nanometre-scale beam-size monitors.

Acknowledgement

The research leading to these results received funding from the European Union’s Horizon Europe MSCA programme under grant agreement No. 101086276. Dr. Konstantin Popov was supported by the KEK “Support Program for Long-term Overseas Research.” The authors are also grateful for support from TYL-FJPPN. This work was additionally supported by the MEXT programm “Development of key element technologies to improve the performance of future accelerators,” Japan Grant Number JPMXP1423812204. Part of the instrumentation was funded by the “Investissements d’Avenir” programme launched by the French Government and implemented by the Agence Nationale de la Recherche (ANR) under reference ANR-21-ESRE-0029 (ESR/Equipex+ T-REFIMEVE).

References

  1. [1]S. Boogert et al., “The International Linear Collider beam polarimeters at the Z-pole”, J. Instrum. 4, P10015 (2009), doi:10.1088/1748-0221/4/10/P10015
  2. [2]D. Charlet et al., “Conceptual study of a Compton polarimeter for the upgrade of the SuperKEKB collider with a polarized electron beam”, J. Instrum. 18, P10014 (2023), doi:10.1088/1748-0221/18/10/P10014DOI
  3. [3]T. Suehara et al., “A nanometer beam size monitor for ATF2”, Nucl. Instrum. Methods Phys. Res. A, 616, pp. 1–8 (2010), doi:10.1016/j.nima.2010.02.065DOI
  4. [4]K. Popov, A. Aryshev J. Urakawa and N. Terunuma, “KEK LUCX facility laser-to-RF&RF-to-RF stability study and optimization”, in Proc. IPAC2022 (Bangkok, Thailand, 2022), JACoW, TUPOT066 (2022), doi:10.18429/JACoW-IPAC2022-TUPOT066
  5. [5]Y. Koshiba et al., “Harmonically mode-locked laser pulse accumulation in a self-resonating optical cavity”, Opt. Express 30, 43888-43899 (2022), doi:10.1364/OE.472917DOI
  6. [6]H. Yang et al., “10-fs-level synchronization of photocathode laser with RF-oscillator for ultrafast electron and X-ray sources”, Sci. Rep. 7, 39966 (2017), doi:10.1038/srep39966.DOI
  7. [7]M. S. McCallum, A. Lyapin, M. Bosman, A. Aryshev, K. Popov, and N. Terunuma., “Cavity beam position monitor pulse injection source”, in Proc. IBIC2024 (Beijing, China, 2024), JACoW, TUP17 (2024), doi:10.18429/JACoW-IBIC2024-TUP17DOI
  8. [8]M. S. McCallum et al., “Cavity beam position monitor signal matching by injection pulse”, in Proc. IPAC2025 (Taipei, Taiwan, 2025), JACoW, THPM061 (2025), doi: 10.18429/JACoW-IPAC2025-THPM061
  9. [9]Y. Otake, H. Maesaka, S. Matsubara, N. Hosoda and T. Oshima, “Timing and low-level rf system for an x-ray laser”, Phys. Rev. Accel. Beams 19, 022001 (2016), doi:10.1103/PhysRevAccelBeams.19.022001DOI
  10. [10]Y. S. Cheng, K. H. Hu, C. Y. Wu, C. Y. Liao and K. T. Hsu, “Performance of the TPS RF reference distribution links ”, in Proc. IPAC2014 (Dresden, Germany, 2014), JACoW, TUPRI114 (2014), doi:10.18429/JACoW-IPAC2014-TUPRI114DOI
  11. [11]K. Popov, A. Aryshev and N. Terunuma, “KEK ATF Linac, Damping Ring accelerating field and RF-Gun laser system phase&amplitude stability study”, J. Phys. Conf. Ser. 3094, 012044 (2025), doi:10.1088/1742-6596/3094/1/012044DOI
  12. [12]K. Popov, A. Aryshev, H. Kaji, N. Terunuma and T. Okugi, “KEK Accelerator Test Facility Low-Level RF and Timing Systems”, in Proc. LCWS2025 (Valencia, Spain, 2025), in preparation.arxiv.org/abs/2602.00501
  13. [13]T. Masuda, “Timing signal distribution for synchrotron radiation experiments using RF over White Rabbit”, in Proc. ICALEPCS2019 (New York, NY, USA, 2019), JACoW, WEPHA096 (2019), doi:10.18429/JACoW-ICALEPCS2019-WEPHA096DOI
  14. [14]K. Popov, A. Aryshev, N. Terunuma and T. Okugi, “KEK Accelerator Test Facility Timing System Upgrade Status Report”, in Proc. PASJ 2025 (Tokyo, Japan, 2025), WEP009 (2025)
  15. [15]H. Kaji and T. Naito, “Upgrade plan of the bucket selection and timing system at ATF”, in Proc. PASJ 2021 (QST-Takasaki Online, Japan, 2021), MOP039 (2021)
  16. [16]H. Kaji and Y. Itsuka, “Application of the White Rabbit System at SuperKEKB”, in Proc. ICALEPCS2021 (Shanghai, China, 2021), JACoW, THPV027 (2021), doi:10.18429/JACoW-ICALEPCS2021-THPV027DOI
  17. [17]K. Popov et al., “Study of laser-beam arrival time synchronization towards sub-picosecond stability level”, in Proc. IPAC2025 (Taipei, Taiwan, 2025), JACoW, THPM050 (2025), doi:10.18429/JACoW-IPAC2025-THPM050
  18. [18]A. Back et al., “High-Performance Timing architecture Based on White Rabbit: A Metrological Approach”, in preparation
  19. [19]K. Popov, A. Aryshev, N. Terunuma and M. Takano, “FPGA board based cost-effective, robust and flexible online waveform monitors development, test and implementation at KEK Accelerator Test Facility”, in Proc. IPAC2025 (Taipei, Taiwan, 2025), JACoW, THPM049 (2025), doi:10.18429/JACoW-IPAC2025-THPM049DOI
  20. [20]K. Popov, A. Aryshev and N. Terunuma, “KEK ATF integrating current transformer signals data acquisition system upgrade status report”, in Proc. PASJ 2024 (Yamagata, Japan, 2024), FRP013 (2024)
  21. [21]K. Popov, “Digital Low-Level Radio-Frequency phase-amplitude feedback development and its application for KEK LUCX facility stabilization”, Ph.D. thesis, SOKENDAI University (2025). Available at: https://ir.soken.ac.jp/records/2000015
  22. [22]T. Kobayashi et al., “Progress in development of new LLRF control system for SuperKEKB”, in Proc. IPAC2013 (Shanghai, China, 2013), JACoW, WEPME014 (2013)
  23. [23]D. Wang et al., “Analysis and stabilization of AC line synchronized timing system for SuperKEKB”, Nucl. Instrum. Methods Phys. Res. A, 1015, pp. 1–17 (2021)DOI

Paper details

vlnc:W_hnbnf9f8
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents