betaFeedback

WorksPhysics and Astronomy

Diagnosing internal leakage currents through magnetometry of lithium-ion cells

Abstract

Internal leakage currents are difficult to detect and to localize through measurements at the terminals of lithium-ion cells. We measured the magnetic fields of pouch cells non-invasively with a magnetometer while a battery cycler set the current and recorded the voltage. A three-axis magnetoresistive sensor remains fixed inside a three-layer magnetic shield, and two linear stages move the cell in two dimensions relative to the sensor to acquire a map of the magnetic field above the cell. The field of an intact cell was linear in current from 10 to 420 mA, and its maps were symmetric between charge and discharge. To create internal leakage currents, two 600 mAh cells were damaged by mechanical indentation. Both cells developed a magnetic field at zero applied current that decayed over hours, while the cell voltage showed a loss of charge by self-discharge. This field breaks the symmetry between the charge and discharge maps, which allows leakage to be detected while the cell is being cycled. At rest, the setup detects leakage currents down to about 1–3 mA. The results highlight opportunities for battery diagnostics and safety, and may help in designing techniques for characterizing soft shorts.

Paper details

vlnc:W_j6xgae7v
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
arXiv nonexclusive license
Usage

views · 8

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement