betaFeedback

WorksComputer Science

From archive to resource: bringing legacy data back to life at scale with large language models

Abstract

Pharmaceutical companies maintain vast archives of legacy preclinical study reports that contain study-context details, such as fasting, anesthesia, and laboratory instrumentation, that are rarely captured in structured data formats, yet they can correlate with clinical pathology parameters values and limit the reuse of historical data. This work demonstrates practical, scalable solutions to recover such descriptors from heterogeneous report texts using large language model (LLM)-based extraction pipelines developed independently by two industry teams. The pipelines identify and normalize metadata fields and return verbatim evidence with page and section reference, hasting human verification and iterative refinement. Evaluation of over 400 documents against expert-curated reference values showed high agreement across a broad set of metadata fields. Performance was strongest for consistently reported items and lower for descriptors subject to linguistic or report structure variability. Extraction time has shrunk from 25 minutes in the manual benchmark to 1.6 minutes. As a concrete biological demonstration, we show that fasting status extracted from report text was associated with species- and analyte-specific shifts in clinical chemistry parameters, illustrating how recovered metadata can improve selection of historical controls. Key strengths of the approach are scalability, traceability, and the ability to recover information missing from current industry standards. Main limitations are dependence on source-report quality and initial expert effort to define and refine schemas. These results establish how LLMs can convert heterogeneous, unstructured legacy reports into evidence-grounded, reusable and structured metadata, leading to better experimental comparability, and thus enabling reliable data pooling or informed virtual control selection.

Correspondence:

Corresponding Authors

[email protected]

[email protected]

shared first author

Introduction

Pharmaceutical companies hold large collections of legacy preclinical study data from toxicology, safety pharmacology, and pharmacokinetic programs accumulated over decades. When made findable, accessible, interoperable and reusable (FAIR) [33], these data can support cross-study safety assessments, evidence-based portfolio decisions [1], and the reuse of historical information in line with the 3R principles of Replacement, Reduction, and Refinement [21]. One application in which reuse of historical data may directly contribute to the 3Rs is the construction of virtual control groups (VCGs), as proposed by the Innovative Health Initiative-funded “Developing and implementing VIrtual Control groups To reducE animal use in toxicology Research” (VICT3R) consortium [27].

VCGs use appropriately matched historical control data (HCD) to replace concurrent control animals in new studies [26]. By providing an alternative to including concurrent control animals, VCGs have the potential to reduce animal use while maintaining an appropriate reference for the interpretation of treatment-related findings, thereby supporting the 3R principle of Reduction. Their utility, however, depends on the availability of HCD that are sufficiently comparable to the animals in the new study [26, 12]. Furthermore, factors such as vehicle composition, diet, fasting conditions, anesthetic protocols, animal supplier, test facility, and housing conditions may affect clinical pathology parameters variability and act as confounders in cross-study comparisons [20]. In addition, other, as-yet-unidentified confounders may also contribute to variability [13]. Many such factors are not consistently represented in current structured preclinical data standards, like CDISC’s Standard for Exchange of Nonclinical Data (SEND) [6], and are instead locked away across different sections of heterogeneous study reports, making their systematic identification challenging. In effect, much of this information is dormant as it has been recorded, but it cannot be used.

Manually recovering this information requires subject-matter expertise and does not scale to the thousands of reports held by companies. Large language models (LLMs) can automate this process, and earlier work at Bayer and Roche showed that they can be used reliably at scale [30, 8]. To our knowledge, three questions remained open: whether this approach can reliably recover the contextual metadata that current preclinical data standards leave out, whether it holds up across different reports with different formats and conventions, and whether the recovered information is accurate enough to impact how historical data are analyzed.

Here, we address all three. Bayer and Roche independently developed LLM-based pipelines that process legacy study reports to extract contextual metadata relevant to VCG construction and not captured in SEND [6], such as fasting and anesthesia before blood sampling. Each extracted value is linked to the paragraph it came from. The two pipelines find relevant text differently: Bayer’s searches each report for the most relevant paragraphs, while Roche’s applies natural language processing (NLP) to identify the report body before passing the text to the language model. Evaluated against expert-curated values across 244 Bayer and 202 Roche reports, both matched expert curation for most study metadata. Finally, we show that the recovered information has analytical value: fasting status, available only in report text, was associated with changes in clinical chemistry parameters in control animals, making it a candidate matching criterion for VCGs. Together, these results show that information lying dormant in legacy reports can be brought back to life, accurately and at scale, to improve the reuse of historical control data and support efforts to reduce animal use in toxicology.

Methods

System Architecture – PRINCE (Bayer)

Extraction of study metadata from preclinical toxicology study reports followed a schema-constrained information extraction approach, in which an LLM populated a predefined set of typed attributes directly from source documents. Each target attribute was treated as a named entity to be located, extracted, normalized, and grounded in the source text. The approach used to process unstructured text from study reports has been described previously Vieira-Vieira et al. [30]. In brief, source study reports were pre-processed into text chunks and indexed in an OpenSearch vector store. For a given study, retrieval was restricted to the target study using a pre-filter, and relevant chunks were selected by similarity search within a retrieval-augmented generation (RAG) framework.

Attribute extraction was carried out with the GPT-5.4 model, served through Bayer's internal GenAI platform myGenAssist Benaïche et al. [2]. A fixed system prompt instructed the model to act as an expert extraction algorithm, to extract only information explicitly supported by the provided text, and to return null for any attribute whose value could not be determined. The study report text chunks were supplied as the user context, and the model returned one structured object per schema group using structured-output (constrained decoding) mode defined by a Pydantic schema Colvin et al. [5]. Because several attributes were often derived from the same chunks, attributes were organized into thematic schema groups. For fields left unresolved, a focused follow-up query was issued with a smaller retrieval window tailored to the individual attribute, and the structured model was re-invoked.

Finally, extracted values were reconciled with existing values in Bayer’s internal database using one of three rules, depending on the field:

  • Fields absent from the PRINCE database (AGE, AGEU, HOUSETYP, HUMIDTU, LIGHT, TEMPU, WATER, TRTV, EXVAMT, EXDOSFRM, RECSAC, SPLR CTRY, SPLRREG, TSTFNAM, EXENDTC, MANAESTH): the extracted value was accepted unconditionally.

  • Fields where PRINCE curation was more reliable owing to controlled vocabularies or structured entry (SPECIES, EXDOSFRQ, EXDOSTXT, DIET, HOUSEGRP, BW, CL, FW, LB, PP, MA, MI, OM, VS, EG, CV, RE): the PRINCE value was retained when available, and the extracted value was used only as a fallback.

  • Remaining fields present in both sources (STRAIN, GLPFL, HUMIDT, TEMP, ROUTE, DOSDUR, TRT, SPLRNAM, SPLRLOC, STDIR, EXSTDTC): the extracted value was used preferentially, and the PRINCE value substituted only when extraction returned no result.

System architecture - Controlled Generation (Roche)

The preprocessing and LLM-based extraction pipeline adapted a previously published study-report extraction architecture [8] for VCG metadata extraction (Figure 1). The workflow comprised report-core identification, parsing, and optional section selection, which is shown in Figure 1 for completeness, but was not used in this study. Report cores were identified using PyMuPDF Jorj X. McKie, [15] and PyPDF2 Fenniak et al., [11] and parsed using MinerU Wang et al., [31] or olmOCR Poznanski et al., [22]. Detailed preprocessing, fallback logic, and parser selection are provided in supplementary material 3. Metadata was extracted using GPT-4.1 OpenAI, [19], with one call per parsed report section and metadata field. A Pydantic-based schema defined field-specific extraction instructions and output formats (Supplementary Figure 1). Fields were selected based on SEND, relevance to preclinical toxicity studies, and VICT3R historical-control requirements EMA, [9], with study-specific extensions relevant to enable cross-study comparison and VCG development. Complete field definitions, SEND mappings, extension-field rationale, and output-handling rules are provided in supplementary table 1 and supplementary material 3.

Iterative human curation of reference values with LLM assistance

In both the Bayer and Roche workflows, extraction pipelines were evaluated at the level of individual metadata fields against manually curated reference values. For every extracted content item, the pipeline returned the extracted value, the verbatim text on which the value was based, the page number of that text, and the name of the report section from which it originated. This traceability information accelerated human curation by reducing the need for manual searching. It also enabled curators to distinguish between two error categories:

  • Incorrect source selection: the model based its answer on a report section that did not contain the requested information. These cases typically indicated preprocessing errors (exclusion of the title page and, with it, the test facility name and location) or insufficient detail in the initial task formulation. For example, by not specifying the required detail level about hematology assays and instruments.

  • Incorrect interpretation of a correct source: the model identified the correct section but drew an incorrect conclusion from it. These errors were mainly attributable to subtle details in the prompt formulation for specific items and were addressed by refining the extraction instructions with domain experts.

This cycle of automatic extraction, human curation, and prompt refinement was repeated until all entities were manually validated for the reports labeled as the test dataset.

Automatic evaluation with LLM-as-a-Judge

Correctness against the manually curated reference values was assessed automatically by an LLM-as-a-Judge. The judge model was provided with the extracted value, the curated value, and the description of the corresponding metadata field, and was instructed to classify each extracted value as "Correct", "Partially Correct", or "Incorrect". A value was marked "Correct" when it was verbatim or semantically identical to the curated value, "Partially Correct" when it partially matched the curated value (for example, "Oral" or "Intragastric" extracted when the curated value was "Oral Gavage"), and "Incorrect" when it differed from the curated value. The judge could additionally output "Not Extracted" when no value was found in the source document, "No Curation and Not Extracted" when no curated value existed and nothing was extracted, and "No Curation and Extracted" when no curated value existed but a value was nevertheless extracted.

An example of the instruction provided to the LLM-judge in the Bayer pipeline is given in supplementary material 1. From these categories, a common confusion matrix was defined and used to derive precision, recall, and F1 score:

  • True Positives (TP): values that fully or partially matched the curated value.

  • False Positives (FP): values that did not match the curated value, or values that were extracted although no curated value existed.

  • True Negatives (TN): cases in which no curated value existed, and no value was extracted.

  • False Negatives (FN): cases in which a curated value existed, but no value was extracted.

A curated value of "Not Available" indicated that the entity was absent from the study report and therefore could not have been legitimately extracted and any value returned for such a field was counted as a false positive. Representative examples for each category are shown in Table 1.

Linear mixed-effects model

To illustrate how the extracted metadata can support biological analyses, we examined the association between fasting status and clinical chemistry values in monkeys and rats. Studies were excluded if fasting status was unclear or not found during extraction. Values were log-transformed because their distributions were right-skewed and their spread increased with the mean; fasting effects are therefore expressed as fold changes. For each of the 16 species-analyte combinations (2 species x 8 analytes), we fitted:

log⁡(Yij)=β0+βfast⋅Fj+βsex⋅Sij+βspec⋅Pj+uj+εij,uj∼N(0,σu2), εij∼N(0,σ2)\log(Y_{ij}) = \beta_0 + \beta_{\mathrm{fast}} \cdot F_j + \beta_{\mathrm{sex}} \cdot S_{ij} + \beta_{\mathrm{spec}} \cdot P_j + u_j + \varepsilon_{ij}, \quad u_j \sim\mathcal{N}(0, \sigma_u^2), \ \varepsilon_{ij} \sim\mathcal{N}(0, \sigma^2)

where β0\beta_0 is the intercept, yijy_{ij} is the analyte value for animal ii in study jj, FjF_j is a dummy variable for fasting status (1 = fasted, 0 = unfasted), SijS_{ij} is a dummy for sex (1 = male, 0 = female), and PjP_j is a dummy for specimen type (1 = plasma, 0 = serum). All fixed terms are main effects (coefficient × indicator variable) and no interaction terms were included in these models. β0\beta_0 is the intercept, for example the mean log analyte value in the reference group (unfasted, female, serum), and the coefficients βfast\beta_{\mathrm{fast}}, βsex\beta_{\mathrm{sex}}, and βspec\beta_{\mathrm{spec}} represent the adjusted differences associated with fasting, male sex, and plasma specimens, respectively. uju_j is the random intercept for study jj, representing study-level variation in the outcome, and ϵij\epsilon_{ij} is the animal-level residual. Models were fitted with restricted maximum likelihood using statsmodels v0.14.4 library, with Wald-based confidence intervals and p-values. Fasting p-values were corrected across the 16 tests using the Benjamini-Hochberg procedure [3]. These 16 models were fitted within species and provide all reported fold changes, confidence intervals and q-values.

A separate model per analyte, fitted on the pooled species data with a fasting-by-species interaction, contributed only the interaction p-value. Given the limited number of unfasted studies per species (12 monkey, 9 rat), this test was interpreted as a qualitative indicator of species differences, rather than as evidence of equivalence when non-significant. Animal age at study start and test facility were assessed as study-level confounders and excluded: age was balanced across fasting arms, and facility was nearly collinear with fasting and therefore absorbed by the study random intercept. Each model thus estimates the fasting-associated shift in one analyte and species, adjusted for sex, specimen type and between-study variation.

Results

Bayer results

To assess the performance of the Bayer extraction pipeline, metadata for 205 studies were manually curated to serve as reference values. This set of studies was named the training set. The only selection criterion for the training set was the availability of a study report for studies donated by Bayer AG to the VICT3R consortium up to August 2025. The training set comprised 165 GLP and 40 non-GLP studies. The oldest study dated 1991, and the median exposure start date was 2015 (range: 1991–2021).

Manual extraction of all 44 metadata fields across 205 studies required approximately 86 hours, corresponding to 25 minutes per study, when performed by a subject matter expert familiar with the diverse report formats. Non-GLP studies were particularly challenging because some parameters were not reported and, therefore, could not be curated from the study report alone. Where possible, curation was supplemented by other company-internal metadata sources, such as study director records or LIMS systems. Consequently, in some cases, perfect agreement between manually curated reference values and automated extractions from study reports alone cannot be achieved, as the report was the only source for the latter.

To establish a baseline comparison, we first compared previously annotated values in Bayer AG’s internal database for preclinical studies, PRINCE [30], against the manually curated reference values (Figure 2A and Supplementary Figure S2A). In the PRINCE database, recall (mean: 81.8 ± 28.2%; median: 98.2%), precision (mean: 92.1 ± 16.0%; median: 100.0%), and F1 score (mean: 82.5 ± 24.7%; median: 92.3%) varied substantially across metadata fields, reflecting historical variation in metadata collection and reporting standards. Information on animal housing conditions (HUMIDT, TEMP, DIET) and dosing frequency (EXDOSFRQ) was often not present. In addition, many exposure start dates (EXSTDTC) were incorrect, likely due to the mismatched definitions for experimental start and exposure start in legacy systems from which PRINCE originally sourced data.

Image not extracted

Figure 2. Per-field confusion matrix benchmarked against manually curated metadata fields. Training set (n = 205), PRINCE baseline (A); Training set (n = 205), PRINCE plus extraction pipeline combined output after rule-based merging (B); Validation set (n = 39), PRINCE baseline (C); and validation set (n = 39), PRINCE plus extraction pipeline combined output after rule-based merging (D). In combined panels (B and D), bold field labels indicate metadata fields not present in PRINCE.

Pydantic schema for TestFacilityItem, showing extracted value, source page, and verbatim evidence fields

Figure S2.

Next, the extraction pipeline was applied to study reports from all 205 studies in the training set. Extraction was performed iteratively: output from each round was manually reviewed and used to refine field-specific prompts. Early prompts used generic instructions, whereas later prompts incorporated more precise guidance on likely report sections and expected wording. Single-shot examples derived from previous iterations were also added to harmonize outputs. The final prompt used for the STRAIN metadata field is provided in supplementary material 2.

Automated extraction of all 44 metadata fields with the final prompts required 5.5 hours, corresponding to 1.6 minutes per study, and was limited mainly by LLM inference latency and extracted metadata fields were compared against the manually curated reference values (Figure 2B and Supplementary Figure S2B). Across the 28 metadata fields also available in the PRINCE database, average recall (mean: 99.8±0.5%99.8 \pm0.5\%; median: 100.0%100.0\%), precision (mean: 97.9±2.4%97.9 \pm2.4\%; median: 98.5%98.5\%), and F1 score (mean: 98.8±1.3%98.8 \pm1.3\%; median: 99.3%99.3\%) were markedly higher than the PRINCE baseline. Recall, precision, and F1 score across all 44 extracted metadata fields were also high (means: 95.8±11.8%95.8 \pm11.8\%, 96.2±10.1%96.2 \pm10.1\%, and 95.6±11.2%95.6 \pm11.2\%, respectively; medians: 99.8%99.8\%, 98.5%98.5\%, and 98.7%98.7\%). Importantly, metadata fields absent from or poorly annotated in the PRINCE database, including HUMIDT, TEMP, DIET, EXDOSFRQ, and EXSTDTC, were successfully extracted from study reports.

Performance varied across metadata fields. Extraction of anesthesia method (MANAESTH), a non-standard SEND metadata field that was often not reported in study reports, was substantially weaker than for other fields, likely because reporting was inconsistent (recall: 55.7%55.7\%, precision: 32.5%32.5\%). Animal supplier country (SPLRCTRY) was frequently not extracted (recall: 35.5%35.5\%) but was usually correct when extracted (precision: 93.4%93.4\%). Animal age and age units (AGE and AGEU) also showed lower performance, consistent with the frequent absence of this information from study reports.

To assess generalizability, we further evaluated 39 studies that were not included in the training set (Figure 2C and Figure 2D, and Supplementary Figure S2C and Supplementary Figure S2D). This set of studies was named the validation set and included 20 GLP and 19 non-GLP studies. The median exposure start date was 2021 (range: 2009–2023). As before, metadata fields were manually extracted to serve as reference values. The extraction pipeline was then applied using the final prompts developed on the training set and extracted metadata fields were merged with previously available PRINCE annotations.

On the validation set, extraction performance across the 28 PRINCE-comparable metadata fields remained comparable to the training set, with recall of 99.1±2.2%99.1 \pm2.2\% (median: 100.0%100.0\%), precision of 95.1±7.1%95.1 \pm7.1\% (median: 97.4%97.4\%), and an F1 score of 97.0±4.6%97.0 \pm4.6\% (median: 98.7%98.7\%). The modest reduction in precision relative to the training set was likely attributable to fields with no extractable report value or no available curated reference value, consistent with the higher proportion of non-GLP studies in the validation set (19/39 versus 40/205). These results support the generalizability of the extraction approach.

Roche results

The Roche VCG extraction use case of 202 studies covered 10 metadata fields. Absolute TP, FP, TN, and FN counts are visualized in Figure 3A. For Test Facility Name and Test Facility Location, the number of evaluated instances (n = 220) exceeded the number of reports (n = 202), because some studies involved multiple facilities, each scored independently. By contrast, the additional instance for Fasting Status Prior Blood Collection represented a false-positive extraction.

Extraction performance across Roche metadata fields

Figure 3. Extraction performance across Roche metadata fields (N=202N = 202 reports). Stacked bar chart showing absolute counts of true positives (TP), false positives (FP), true negatives (TN), and false negatives (FN) per metadata field (A). Test Facility Name and Test Facility Location include 220 evaluated instances because some studies involved multiple facilities. Grouped bar chart showing accuracy, recall, precision, and F1 score per metadata field, calculated from the counts in A and rounded to the nearest integer (B).

The Roche extraction pipeline showed strong overall performance across evaluated metadata fields, with several fields reaching ceiling-level scores (Figure 3B). Test Facility Name and Test Facility Location achieved 100% accuracy, recall, precision, and F1 score. These fields were typically reported on the report cover page or a dedicated test-site information section, which likely contributed to reliable extraction. These high-performing metadata fields tend to be reported in consistent or formulaic language.

Performance decreased for fields whose wording and surrounding context varied more substantially across CROs and report formats. Anesthesia-related metadata fields showed very high recall (100% for Anesthetic Prior Blood Collection and 99% for Anesthetic Prior Death) but lower precision (73% and 72%, respectively). This indicates that the model identified nearly all relevant information but also produced false positives. One recurrent error pattern was a failure to distinguish anesthetic agents from euthanasia agents when reports listed them without explicitly differentiating their purpose.

The weakest performance was observed for Animal Supplier Name (F1 score: 79%) and Hematology Instrument (F1 scores: 85%). For Animal Supplier Name, errors likely reflected variability in how suppliers were referenced and whether supplier information appeared in report sections retained during preprocessing. Additional ambiguity arose when reports described the geographic origin of the animals but did not provide a supplier identity. For example, in references to “Mauritian cynomolgus monkeys”, the LLM incorrectly interpreted the geographic origin (Mauritius) as the animal supplier. For Hematology Instrument, errors suggest that the extraction instructions did not always compensate for domain-specific ambiguity, such as distinguishing an instrument from associated software or specifying an existing model of the instrument that exists but was not used in this study.

Overall, the Roche extraction pipeline achieved high reliability for structured and consistently expressed metadata fields, whereas performance was lower for fields with greater linguistic variability or domain-specific ambiguity.

Fasting status as a relevant selection criterion for virtual control groups

To demonstrate the utility of metadata extracted from study reports for VCG construction, we examined the association between Fasting Status Prior Blood Collection and eight clinical chemistry analytes: alanine aminotransferase (ALT), alkaline phosphatase (ALP), aspartate aminotransferase (AST), calcium, cholesterol, glucose, phosphate, and triglycerides. Only cynomolgus monkeys and Wistar Han rats had enough fasted and unf fasted studies for analysis: 44 fasted and 12 unfasted monkey studies, and 31 fasted and 9 unfasted rat studies (Figure 4A). Other species and/or strains were excluded because too few studies were available in one or both groups.

Image not extracted

Figure 4. Fasting status and its impact on clinical pathology parameters. Number of studies and control subjects included in the fasting-status models (A). Counts are shown for analytes with complete panel coverage. Fasting effect on control clinical chemistry in cynomolgus monkey and Wistar Han rat. Per-animal control values (boxes, log scale) and per-study means (black dots) for eight analytes in fasted (green) versus unfasted (orange) studies. Brackets mark the modelled fasting

Fasting was associated with analyte- and species-specific shifts in clinical chemistry parameters (Figure 4B and C). As expected, after FDR correction, fasting was associated with lower glucose in cynomolgus monkeys (fold change: 0.87; 95% CI: 0.79–0.96; q=0.033q = 0.033), lower triglycerides in Wistar Han rats (fold change: 0.59; 95% CI: 0.41–0.85; q=0.033q = 0.033), and higher phosphate in cynomolgus monkeys (fold change: 1.12; 95% CI: 1.04–1.20; q=0.033q = 0.033). The fasting effect differed by species for triglycerides (interaction p=0.009p = 0.009) and phosphate (interaction p=0.037p = 0.037), supporting the decision to model species separately.

ALT, AST, calcium, and cholesterol showed no significant fasting-associated shift in either species. Rat ALP decreased by 25%, but this effect did not remain significant after FDR correction. Fasting therefore shifted values for three of eight analytes, and the affected analytes differed between species, making fasting status a relevant matching criterion for glucose and phosphate in cynomolgus monkeys and for triglycerides in Wistar Han rats. For the remaining analytes, we found no evidence that matching on fasting status is required, although the small number of unfasted studies does not exclude smaller effects.

It must be noted that fasting was nearly collinear with test facility. Therefore, facility-level differences, such as the analytical platform used, cannot be separated from the fasting effects, and the results, although physiologically justifiable, should be interpreted as associations.

Discussion

Pharmaceutical companies often revisit historical study data to inform contemporary drug development ([23, 25, 32]). In this study, Bayer and Roche independently developed LLM-based pipelines to recover contextual metadata from heterogeneous historical preclinical study reports. Both approaches achieved high agreement with expert curation (Figure 2 and Figure 3), showing that metadata previously accessible only through costly, time-consuming manual review can be extracted at scale.

Preclinical data is increasingly pooled across companies to develop predictive models and improve translation of findings between humans, nonclinical species, and in-vitro systems ([24, 21, 10, 27]). Missing study descriptors are particularly relevant for VCGs construction ([13, 20]), as these descriptors are used to select suitable historical control animals ([27]). The value of metadata extraction lies not only in its accuracy, but also in whether the recovered metadata is scientifically informative. We showed here that fasting status before blood collection was associated with significant differences in clinical chemistry parameters values (Figure 4). Our findings therefore support capturing fasting status in structured form in future versions of preclinical data standards, consistently with previous observations that current standards do not capture all relevant study-level metadata ([4, 21, 29]).

Methodological lessons, limitations, and outlook

Both extraction architectures from Vieira-Vieira et al. [30] and Doktorova et al. [8] achieved similarly strong performance. Most false positives and missed values arose from linguistic variability, domain-specific ambiguity, and differences in reporting practices across test facilities and time periods, highlighting the influence of reporting heterogeneity on extraction quality. Altogether, these support the notion that ensuring robust parsing and document access and building pragmatic validation workflows, yield greater benefit than optimizing the extraction architecture (Li et al., 2024, 2025).

In both settings, extraction issues could be mitigated through iterative schema refinement, clearer extraction instructions, and targeted prompt updates. The fact that both pipelines retain verbatim evidence and report location is particularly important in this context, because it enables efficient human review and creates a foundation for automated verification and retry-based correction when outputs are uncertain [7] (Wu et al. 2025).

One bottleneck in our approaches is adaptation to new domains. While the approaches are extensible, defining metadata schemas and extraction instructions still requires manual expert input [14]. Emerging methods for automated performance assessment, prompt optimization, and agent-based support for requirement elicitation and schema drafting may help reduce this burden [28, 36, 16] (Zhang et al. 2025).

In conclusion, information that has lain dormant in preclinical study reports can be unlocked and leveraged for new research purposes: LLM-based extraction recovers it accurately, at scale and with traceable evidence. Such metadata strengthens the evidence base for translational and regulatory decisions and supports efforts to reduce animal use.

Conflict of Interest

C.H.V.-V., A.K. are employed by Bayer AG. I.S.C., A.S., M.C.M., P.L.B.M., G.D.N, T.Y.D. are employed by Roche. The authors declare no further conflicts of interest.

Author Contributions

CHVV: Writing – original draft, review & editing, Methodology, Investigation, Conceptualization, Data Curation.

ISC: Writing – original draft, review & editing, Methodology, Investigation, Conceptualization; Data Curation.

AS: Writing – original draft, review & editing, Methodology, Formal Analysis, Data Curation.

MCM: Writing - original draft, review & editing, Investigation, Formal Analysis, Supervision

PLBM: Writing - original draft, review & editing, Data Curation GDN: Writing - original draft, review & editing, Methodology, Project administration, Conceptualization

TYD: Writing – original draft, review & editing, Investigation, Conceptualization, Data Curation

AK: Writing – original draft, review & editing, Investigation, Project administration, Conceptualization.

Funding

VICT3R is supported by the Innovative Health Initiative Joint Undertaking (IHI JU) under grant agreement No 101172693. The JU receives support from the European Union’s Horizon Europe research and innovation programme and COCIR, EFPIA, Europa Bío, MedTech Europe, and Vaccines Europe and Instem Scientific Limited. This project is funded by the European Union, the private members, and those contributing partners of the IHI JU. Views and opinions expressed are, however, those of the author(s) only and do not necessarily reflect those of the aforementioned parties. Neither of the aforementioned parties can be held responsible for them.

The author(s) declare that no further financial support was received for the research, authorship, and/or publication of this article.

Acknowledgments

The authors gratefully acknowledge the invaluable contributions of the PRINCE Project Team from Bayer and Dr. Dragomir Ivanov Draganov from Roche.

The authors declare that generative AI was used in the creation of this manuscript. MyGenAssist (internal Bayer Tool) was utilized solely for the purpose of enhancing language and readability. Internal ChatGPT (GPT-5.6 Sol) at Roche was used to prepare Figure 1 and Supplementary fig:S1.

Automated extraction and standardization pipeline for study report metadata

Figure 1. Automated extraction and standardization pipeline for study report metadata. The workflow converts PDF reports into structured datasets through: (1) preprocessing, including report core extraction and parsing to Markdown; (2) optional section selection; (3) LLM-based extraction using a predefined schema; and (4) expert curation and quality review. Feedback from expert review was used to refine preprocessing, section extraction, and schema definitions.

Data availability statement

The original contributions presented in the study are included in the article/supplementary material, further inquiries can be directed to the corresponding author.

Figure Legends

Performance metrics for the training and validation sets, comparing PRINCE baseline with PRINCE + NER

Figure 1 (PDF p. 16).

Modelled fasting effects on control clinical chemistry

Figure 5. effect from the study-level mixed model adjusted for sex and specimen matrix (* q<0.05q<0.05, Benjamini–Hochberg FDR across 16 tests) (B). Modelled fasting effect on control clinical chemistry. Fold-change (fasted/unfasted) with 95 % CI from a per-analyte linear mixed model on log values, with a study random intercept and adjustment for sex and specimen matrix; one panel per species, analytes sorted by effect size. Labels give the percentage change. Red = significant after Benjamini–Hochberg FDR correction across the 16 species × analyte tests (C).

Supplementary Materials

Supplementary Material 1

""""""

Evaluation Criteria:

  1. Correctness: An answer is "correct" if it matches the reference answer. Variations in wording, order, expression as a sentence or as a single expression, naming conventions, or minor typos are acceptable as long as the meaning remains accurate in the given context. Numbers can be given as integers or floating point values (e.g. 2 or 2.0) and both are correct. Further specifications are added in the Details later on. Empty answers, "Not Found", "Not Reported", and "Not Available" should all be considered equivalent answers, but not "Not applicable".

  1. Partial Correctness: An answer is "partially correct" if it accurately addresses the question, even if expressed differently, but does not exactly match the reference answer. Here are some examples:

  • An address missing the city but containing the correct country is a partially correct answer;

  • A date containing the correct year and month but not the correct day, should be considered incorrect. Therefore, dates cannot be considered partially correct and must always be correct or incorrect;

  • If time is expressed in number of days, weeks, months or years, approximates are accepted. For example, '28 days', '32 days' or '4 weeks' are all similar answers that should be considered partially correct. Or another example, '91 days', '95 days' or '13 weeks' should also be considered partially correct answers;

  • "ORAL" may be used to express a route of administration via diet (dietary), which in this case indicates a correct answer, but if "ORAL" was used to indicate an "ORAL GAVAGE" route of administration than the evaluation is that the answer was partially correct. Similarly, "intravenous" is only partially correct answer for reference answers "intravenous bolus" and "intravenous infusion";

  • Regarding route of administration, intragastric means the same as oral gavage;

  • "One time" or "single dose" maybe be considered synonyms to "ONCE" when evaluating dosage frequency;

  • "Metal boxes" are synonym for "conventional cages" when evaluating animal housing type;

  • "Kolliphor" and "Solutol" are synonyms components of administration vehicles. Also, the order in which the components of a chemical solution are described do not change the composition of the solution;

  • When comparing codes like "BAY 123456", the presence of a dash does not change the code, meaning "BAY 123-456" would be an equivalent;

  • "Single housed" or "singly housed" are synonyms, and other variations of the terminology are acceptable:

  • "Filtered water" and "Tap water" are synonyms;

  • If a number range is given, consider them partially correct if the answer ranges overlap. For example, "19-24" overlaps with "22-25" but not with "25-27";

  • A person's name may be spelled in full or reduced. For example, "Carlos Vieira-Vieira", "Dr. Carlos Vieira-Vieira", "Dr. C. Vieira-Vieira" are all entries identifying the same person and therefore should be considered as the same;

  • Numbers may be expressed as integers or floats and should be considered as the same number. For example, "2017" and "2017.0" should be considered as the same number, and therefore correct;

  1. **Imprecision:** Any answer that does not accurately address the question, contains significant misunderstandings or is not reflecting all important aspects of the reference answer, should be marked as "Incorrect".

  1. **Additional Considerations:**

Technical Terminology: Ensure your account for relevant technical terms in toxicology and biology.

Order of Information: The order of items in answers does not affect precision, especially for categories where multiple entries may exist. Multiple answers are often divided by semicolons or structured as an array.

**Details:**

  • **Category and Explanation**: {field} : {flat_field_descriptions[field]}

  • **Student's Answer**: {extracted_answer}

  • **Reference Correct Answer**: {curated_answer}

**Instructions:**

  • Compare the student's answer to the correct answer based on the criteria above.

  • Your reply should include only your final assessment: correct, partially correct or incorrect.

""""

Supplementary Material 2

""""

The strain of the animals used in this study. Typical strains are the following: GOTTINGEN, CYNOMOLGUS, WISTAR WU, SPRAGUE-DAWLEY, RNU, NMRI, DOMESTIC SHORT HAIR, B6C3F1, CD1(ICR), CB6F1-TGN (RASH2), RasH2, SPRAGUE DAWLEY (SD), CRL:CD, WISTAR, BEAGLE, MARMOSET, CHIMPANZEE, NEW ZEALAND, WISTAR HAN, BABOON, RHESUS, ZUCKER, LONG EVANS. Only include the information on the strain, as numbers or other information are not required. Specifically, check in the description of the study for the animal in question and which strain of it was used. The information on the strain may not be always found in the text. In that case, one can assume the strain based on the species of animals used, but first please make sure that the strain information is not present in the text. If pig or minipigs were used, assume GOTTINGEN. If dog was used, assume BEAGLE. If monkey or non-human primate was used, assume CYNOMOLGUS. If rabbit was used, assume NEW ZEALAND. If mouse was used, assume CD1(ICR). If rat was used, assume WISTAR.

Further instructions

The value you extract from the text will likely need to be harmonized before providing the final answer. Below is a json file containing a mapping relationship that you should use. This json contains many examples of harmonized answers (keys in the dictionary) and the values that have been extracted from the text (values in the dictionary). Use it to learn and provide the correctly harmonized final answer.

{
"BEAGLE": ["Beagle", "BEAGLE"],

"CD1(ICR)": ["Crl:CD-1(ICR)BR", "Crl:CD-1 (ICR)BR", "Crl:CD1 (ICR)", "Crl:CD1(Icr)",
"Crl:CD1(ICR)BR", "Crl:CD1 (Icr)", "CD1(ICR)"],

"CYNOMOLGUS": ["CYNOMOLGUS"],

"NEW ZEALAND": ["NEW ZEALAND"],

"SPRAGUE-DAWLEY": ["Sprague Dawley SD"],

"WISTAR": ["Wistar", "WISTAR"],

"WISTAR HAN": ["RccHanWist", "Crl WI:Han", "Crl:Wi(Han)", "RccHan:WIST",
"HsdRCCHan:Wist", "Crl:WI(Han)", "Crl:WI (Han)", "RccHanWIST", "WISTAR HAN", "Crl:
WI (Han)"],

"WISTAR WU": ["HsdCpb:WU [SPF]"],

"CB6F1-TGN (RASH2)": ["RasH2 Mice", "RasH2"]
}
""""

## Supplementary Material 3

Report-core identification used the table of contents (TOC) where available. When automatic TOC detection failed, the initial report pages were extracted and parsed to identify TOC content, and the trigger terms “reference,” “archiving,” and “signature” were used to identify the final page of the report core. Parsing was restricted to pages up to this endpoint. If no reliable endpoint could be identified, the first 100 pages were retained. This occasionally included appendix material but was preferred over potentially excluding information required for extraction.

Parser selection depended on computational resources available at runtime. MinerU required GPU execution, whereas olmOCR supported both CPU and GPU execution.

The extraction schema followed a class-based Python design in which related metadata fields were grouped by topic (Supplementary Figure 1). Each field specified its extraction instructions and required output format. Study-specific extension fields captured information not consistently represented in available structured metadata but considered relevant to cross-study comparison and VCG development. Anesthesia before blood collection was included, for example, because anesthesia protocols can substantially affect clinical-pathology measurements and therefore historical-control comparability [13].

All metadata fields, corresponding SEND variables or domains where applicable, and extraction definitions are provided in Supplementary Table 1. If a field could not be extracted, the pipeline returned a standardized missing-value response. For GLP status, recovery period, and SEND-domain measurement availability, absence of evidence was instead encoded as a negative value.

CategoryExtracted valueManually curated reference value
True Positive (full)Anesthetic = carbon dioxide inhalationAnesthetic = carbon dioxide inhalation
True Positive (partial)Route of administration = OralRoute of administration = Oral Gavage
False Positive (no ground truth)Fasting status = fastedFasting status = Not Available
False Positive (wrong value)Animal diet = Kliba Nafag #3436Animal diet = Provimi Kliba 3437
True NegativeAnimal supplier = "No clear answer"No value available in the report
False NegativeAnimal supplier = "No clear answer"Animal supplier = Ellegaard Göttingen Minipigs A/S, DK-4261 Dalmose, Denmark

Table 1. Examples of confusion-matrix categories from study reports. “No clear answer” denotes a standardized missing-value response indicating that no value was extracted.

Supplementary Table 1

CategoryMetadata fieldSEND variable/domainExtraction definition used in this studyMissing-value instruction
Animal characteristicsAnimal speciesSPECIESSpecies of the test animalsNot reported
Animal characteristicsStrainSTRAINStrain of the test animalsNot reported
Animal characteristicsAge at start of experimentAGE, AGEUAge of animals at the start of the experimental phase, including unitNot reported
HusbandryBasal dietDIETDiet given to study animalsNot reported
HusbandryDrinking waterWATERWater provided to study animalsNot reported
Study conductGood laboratory practice flagGLPFLGLP conditionsNegative if absent
HousingHousing groupHOUSEGRPAnimal grouping or housing groupNot reported
HousingCage typeHOUSETYPCage used for animal housingNot reported
HousingHumidityHUMIDT, HUMIDTUReported humidity conditions, including unitNot reported
HousingLight cycleLIGHTReported light/dark cycleNot reported
HousingTemperatureTEMP, TEMPUReported room or housing temperature, including unitNot reported
SupplierAnimal supplier countrySPLRCTRYCountry of the animal supplierNot reported
SupplierAnimal supplier locationSPLRLOCLocation of the animal supplierNot reported
SupplierAnimal supplier nameSPLRNAMName of the entity that supplied or sourced the animalsNot reported
SupplierAnimal supplier regionSPLRREGRegion of the animal supplierNot reported
Test facilityTest facility nameTSTFNAMName of the facility where the animal study was conductedNot reported
Test facilityTest facility locationNot applicableCity and country where the test facility is locatedNot reported
Study personnelStudy directorSTDIRName of the study directorNot reported
Treatment and dosingTreatmentTRTTest article administered to the animalsNot reported
Treatment and dosingTreatment vehicleTRTVSubstance used as carrier or solvent for the test compoundNot reported
Treatment and dosingRoute of administrationROUTERoute by which the test article or control was administeredNot reported
Treatment and dosingVolume of administrationEXVAMTAdministered dose volumeNot reported
Treatment and dosingDosing frequencyEXDOSFRQFrequency of test article or control administrationNot reported
Treatment and dosingTreatment dosing groupsEXDOSTXTDescription of treatment or dose groupsNot reported
Treatment and dosingTreatment formulationEXDOSFRMFormulation of the administered treatmentNot reported
Treatment and dosingDosing durationDOSDURDuration of treatment or dosing periodNot reported

Table 1 (PDF p. 23). Metadata fields selected for extraction from preclinical toxicity study reports.

Study designRecovery periodRECSACWhether animals were assigned to a recovery period or recovery sacrifice groupNegative if absent
Exposure timingExposure start dateEXSTDTCStart date of treatment or exposureNot reported
Exposure timingExposure end dateEXENDTCEnd date of treatment or exposureNot reported
Measurement domain availabilityBody weight measurementsBWWhether body weight measurements were reportedNegative if absent
Measurement domain availabilityClinical observationsCLWhether clinical observations were reportedNegative if absent
Measurement domain availabilityFood and water intakeFWWhether food and/or water intake measurements were reportedNegative if absent
Measurement domain availabilityLaboratory test resultsLBWhether laboratory test results were reportedNegative if absent
Measurement domain availabilityPharmacokinetic parametersPPWhether pharmacokinetic parameters were reportedNegative if absent
Measurement domain availabilityMacroscopic findingsMAWhether macroscopic pathology findings were reportedNegative if absent

Table 2.

Measurement domain availabilityMicroscopic findings / histopathologyMIWhether microscopic pathology or histopathology findings were reportedNegative if absent
Measurement domain availabilityOrgan measurementsOMWhether organ weight or organ measurement data were reportedNegative if absent
Measurement domain availabilityVital signsVSWhether vital signs were reportedNegative if absent
Measurement domain availabilityECG test resultsEGWhether electrocardiography test results were reportedNegative if absent
Measurement domain availabilityCardiovascular test resultsCVWhether cardiovascular test results were reportedNegative if absent
Measurement domain availabilityRespiratory test resultsREWhether respiratory test results were reportedNegative if absent
AnesthesiaAnesthetic before blood collectionStudy-specific; proposed label: MANAESTH_BLOODAnesthetic administered before blood collectionNot reported
AnesthesiaAnesthetic before euthanasiaStudy-specific; proposed label: MANAESTH_DEATHAnesthetic administered before euthanasia or sacrificeNot reported

Table 27.

FastingFasting status before blood collectionStudy-specificFasting status of animals before blood sampling for serum chemistry or hematologyNot reported
FastingFasting status before sacrifice or necropsyStudy-specificFasting status of animals before sacrifice, euthanasia, or necropsy preparationNot reported
HematologyHematology instrumentStudy-specificName or model of the analyzer used for hematology analysesNot reported

Figure 1 (PDF p. 28). Example of the prompt formulation for the Test Facility extraction item and its structure as an object.

Supplementary Figure 2

Per-field distribution of extraction outcomes benchmarked against manually curated metadata fields. Stacked bar plots are shown for: Training set (n = 205), PRINCE baseline (A); Training set (n = 205), PRINCE plus extraction pipeline combined output after rule-based merging (B); Validation set (n = 39), PRINCE baseline (C); and validation set (n = 39), PRINCE plus extraction pipeline combined output after rule-based merging (D). In combined panels (B and D), bold field labels indicate metadata fields not present in PRINCE.

Evaluation group percentages for the training and validation sets under PRINCE baseline and PRINCE + NER

Figure 6 (PDF p. 30).

References

  1. [1]Alharbi, E., Skeva, R., Juty, N., Jay, C., and Goble, C. (2023). A FAIR-Decide framework for pharmaceutical R&D: FAIR data cost-benefit assessment. Drug Discov Today 28, 103510. doi: 10.1016/j.drudis.2023.103510DOI
  2. [2]Benaïche, A., Billaut-Laden, I., Randriamihaja, H., and Bertocchio, J.-P. (2025). Assessment of the Efficiency of a ChatGPT-Based Tool, MyGenAssist, in an Industry Pharmacovigilance Department for Case Documentation: Cross-Over Study. Journal of Medical Internet Research 27, e65651. doi: 10.2196/65651DOI
  3. [3]Benjamini, Y., and Hochberg, Y. (1995). Controlling the false discovery rate: a practical and powerful approach to multiple testing. J. R. Stat. Soc. Ser. B Methodol. 57, 289–300. doi: 10.1111/j.2517-6161.1995.tb02031.xDOI
  4. [4]Briggs, K. (2017). Making sense of SEND; the Standard for Exchange of Nonclinical Data. Regul Toxicol Pharmacol 91, 77–85. doi: 10.1016/j.yrtph.2017.10.012DOI
  5. [5]Colvin, S., Jolibois, E., Ramezani, H., Garcia Badaracco, A., Dorsey, T., Montague, D., et al. (2026). Pydantic Validation. Available at: https://github.com/pydantic/pydantic
  6. [6]CDISC. (2021). Standard for Exchange of Nonclinical Data Implementation Guide: Nonclinical Studies, Version 3.1.1 Final. Clinical Data Interchange Standards Consortium. Available at: https://www.cdisc.org/standards/foundational/send
  7. [7]Dao, N., Quesada, L., Hassan, S. M., Campo, M. I., Johnson, S., Ghose, S., et al. (2025). Generative artificial intelligence for automated data extraction from unstructured medical text. JAMIA Open 8, ooaf097. doi: 10.1093/jamiaopen/ooaf097DOI
  8. [8]Doktorova, T. Y., Chernov, I. S., Formaggio, A., Zheng, X., Serra, A., Mohan, P. L. B., et al. (2026). Transforming animal study toxicology reports into structured, harmonized data using large language models. Arch Toxicol 100, 4105–4134. doi: 10.1007/s00204-026-04414-yDOI
  9. [9]EMA (2026). Draft Qualification opinion for Virtual Control Groups (VCG) to replace Concurrent Control Groups (CCG) in rat non-GLP Dose-Range Finding (DRF) studies. Available at: https://www.ema.europa.eu/en/documents/other/draft-qualification-opinion-virtual-control-groups-vcg-replace-concurrent-control-groups-ccg-rat-non-glp-dose-range-finding-drf-studies_en.pdf
  10. [10]FDA (2025). Predictive Modeling of Hepatotoxicity in Animals App-a-thon: Leveraging the Standard for Exchange of Nonclinical Data (SEND) - precisionFDA Challenge. precisionFDA. Available at: https://precision.fda.gov/challenges/35/intro (Accessed October 5, 2026).
  11. [11]Fenniak, M., Stamy, M., pubpub-zz, Thoma, M., Peveler, M., exiledkingcc, and pypdf Contributors (2024). The pypdf library. Available at: https://pypi.org/project/pypdf/
  12. [12]Golden, E., Allen, D., Amberg, A., Anger, L. T., Baker, E., Baran, S. W., et al. (2024). Toward implementing virtual control groups in nonclinical safety studies. ALTEX 41, 282–301. doi: 10.14573/altex.2310041DOI
  13. [13]Gurjanov, A., Kreuchwig, A., Steger-Hartmann, T., and Vaas, L. a. I. (2023). Hurdles and signposts on the road to virtual control groups-A case study illustrating the influence of anesthesia protocols on electrolyte levels in rats. Front Pharmacol 14, 1142534. doi: 10.3389/fphar.2023.1142534DOI
  14. [14]Hein, D., Christie, A., Holcomb, M., Xie, B., Jain, A. J., Vento, J., et al. (2025). Iterative refinement and goal articulation to optimize large language models for clinical information extraction. npj Digit. Med. 8, 301. doi: 10.1038/s41746-025-01686-zDOI
  15. [15]Jori X. McKie (2026). PyMuPDF (1.24.13). Available at: https://github.com/pymupdf/PyMuPDF
  16. [16]Khanmohammadi, R., Ghanem, A. I., Verdecchia, K., Hall, R. D., Elshaikh, M., Luo, B., et al. (2025). Hybrid Student-Teacher Large Language Model Refinement for Cancer Toxicity Symptom Extraction., in 2025 IEEE EMBS International Conference on Biomedical and Health Informatics (BHI), 1–7. doi: 10.1109/BHI67747.2025.11269490DOI
  17. [19]OpenAI (2025). Introducing GPT-4.1 in the API. Available at: https://openai.com/index/gpt-4-1/ (Accessed October 5, 2026).
  18. [20]Palazzi, X., Anger, L. T., Boulineau, T., Grevot, A., Guffroy, M., Henson, K., et al. (2024). Points to consider regarding the use and implementation of virtual controls in nonclinical general toxicology studies. Regul Toxicol Pharmacol 150, 105632. doi: 10.1016/j.yrtph.2024.105632DOI
  19. [21]Pognan, F., Steger-Hartmann, T., Díaz, C., Blomberg, N., Bringezu, F., Briggs, K., et al. (2021). The eTRANSAFE Project on Translational Safety Assessment through Integrative Knowledge Management: Achievements and Perspectives. Pharmaceuticals (Basel) 14, 237. doi: 10.3390/ph14030237DOI
  20. [22]Poznanski, J., Rangapur, A., Borchardt, J., Dunkelberger, J., Huff, R., Lin, D., et al. (2025). olmOCR: Unlocking Trillions of Tokens in PDFs with Vision Language Models. doi: 10.48550/arXiv.2502.18443DOI
  21. [23]Salami, H., Smith-Goettler, B., and Yadav, V. (2025). How can language models assist with pharmaceuticals manufacturing deviations and investigations? Int J Pharm 669, 125100. doi: 10.1016/j.ijpharm.2024.125100DOI
  22. [24]Sanz, F., Pognan, F., Steger-Hartmann, T., Díaz, C., eTOX, Cases, M., et al. (2017). Legacy data sharing to improve drug safety assessment: the eTOX project. Nat Rev Drug Discov 16, 811–812. doi: 10.1038/nrd.2017.177DOI
  23. [25]Seedat, N., Tozzi, C., Ardiaca, A. H., Schaar, M. van der, Weatherall, J., and Taylor, A. (2025). Unlocking Historical Clinical Trial Data with ALIGN: A Compositional Large Language Model System for Medical Coding. doi: 10.48550/arXiv.2411.13163DOI
  24. [26]Steger-Hartmann, T., Kreuchwig, A., Vaas, L., Wichard, J., Bringezu, F., Amberg, A., et al. (2020). Introducing the concept of virtual control groups into preclinical toxicology testing. ALTEX 37, 343–349. doi: 10.14573/altex.2001311
  25. [27]Steger-Hartmann, T., Sanz, F., Bringezu, F., and Soininen, I. (2025). IHI VICT3R: Developing and Implementing Virtual Control Groups to Reduce Animal Use in Toxicology Research. Toxicol Pathol 53, 230–233. doi: 10.1177/01926233241303906
  26. [28]Toro, S., Anagnostopoulos, A. V., Bello, S. M., Blumberg, K., Cameron, R., Carmody, L., et al. (2024). Dynamic Retrieval Augmented Generation of Ontologies using Artificial Intelligence (DRAGON-AI). J Biomed Semant 15, 19. doi: 10.1186/s13326-024-00320-3DOI
  27. [29]van Mulligen, E. M., Parry, R., van der Lei, J., and Kors, J. A. (2025). Mapping between clinical and preclinical terminologies: eTRANSAFE’s Rosetta stone approach. J Biomed Semantics 16, 15. doi: 10.1186/s13326-025-00337-2DOI
  28. [30]Vieira-Vieira, C. H., Kulkarni, S. S., Zalewski, A., Löffler, J., Münch, J., and Kreuchwig, A. (2025). From data silos to insights: the PRINCE multi-agent knowledge engine for preclinical drug development. Front Artif Intell 8, 1636809. doi: 10.3389/frai.2025.1636809
  29. [31]Wang, B., Xu, C., Zhao, X., Ouyang, L., Wu, F., Zhao, Z., et al. (2024). MinerU: An Open-Source Solution for Precise Document Content Extraction, v2.1.1. doi: 10.48550/arXiv.2409.18839
  30. [32]Warner, J., Teodoro, L. H. D. S., Jardim, A. P., and Albera, C. (2026). Intelligent Automation Improved Efficiency in Pharmacovigilance Safety Signal Assessment. Clin Pharmacol Ther. doi: 10.1002/cpt.70409DOI
  31. [33]Wilkinson, M. D., Dumontier, M., Aalbersberg, I. J. J., Appleton, G., Axton, M., Baak, A., et al. (2016). The FAIR Guiding Principles for scientific data management and stewardship. Sci Data 3, 160018. doi: 10.1038/sdata.2016.18DOI
  32. [36]Zhao, Y., Zhang, B., Hu, X., Ouyang, S., Kim, J., Jain, N., et al. (2024). Improving Ontology Requirements Engineering with OntoChat and Participatory Prompting. Available at: https://www.alphaxiv.org/abs/2408.15256 (Accessed October 5, 2026).DOI

Paper details

vlnc:W_jrke2s38
Version
v1 · latest
Published
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Computer Science

MyGenAssist (internal Bayer Tool), GPT-5.6 Sol (bare)

View statement
Looking for related papers…
Contents