WorksPhysics and Astronomy
First demonstration of four-dimensional vertex reconstruction with the Timepix4 beam telescope
Abstract
The first demonstration of 4D vertex reconstruction at the scale using a silicon pixel detector is reported. Hadronic interactions are produced by directing a mixed-hadron beam onto a fixed target upstream of the Timepix4 beam telescope at the CERN SPS. The resulting particles are reconstructed using 4D track and vertex fits that include time directly alongside the spatial parameters. The vertex time resolution follows the expected statistical scaling with the number of timing measurements, reaching for vertices reconstructed from 16 timing-plane clusters. An irreducible component of remains in the fitted resolution model, including sizeable contributions from the clock distribution and the time reference system rather than from the combination of the timing measurements. The observed scaling down to without an unforeseen resolution floor above represents a significant experimental step towards precision-timing in future high-pile-up detectors.
Email address: [email protected] (D. Bacher)
Introduction
The LHCb Upgrade II, planned for LHC Run 5, targets a 5-fold increase in instantaneous luminosity to [1]. At the resulting pile-up of approximately 40 interactions per bunch crossing, the spatial overlap of primary collisions makes the correct association of tracks and secondary vertices to their production vertices difficult. The proposed strategy exploits the temporal spread of approximately 180 ps among primary collisions within a bunch crossing [2], allowing otherwise ambiguous associations to be resolved using both spatial and temporal information. Simulation studies indicate that a track time resolution of approximately 20 ps, corresponding to a hit time resolution of 50 ps, is required to obtain the target performance [1, 3].
Achieving this precision is primarily a detector challenge. While time resolutions below 50 ps have been demonstrated for prototype sensors and readout ASICs developed within the Timespot and IGNITE projects [4, 5, 6, 7], achieving comparable performance in large-area hybrid assemblies, in which the sensor is bump-bonded to the readout ASIC, has not yet been demonstrated. The best single-hit time resolutions currently achieved for such assemblies are approximately 130 ps with TDCPix [8] and 180 ps with Timepix4 [9]. Lower effective time resolutions must therefore be probed by combining multiple timestamps from different detector planes and tracks. This approach has been demonstrated for beam tracks by the NA62 GigaTracker, which achieved a track time resolution of 65 ps [8], and by the Timepix4 beam telescope, which reached approximately 90 ps [9]. Vertex reconstruction extends this principle to measurements from multiple tracks, providing a direct way to study the scaling of the precision with the number of measurements and to determine whether correlated contributions limit the achievable resolution.
This paper presents such a study using data obtained with the Timepix4 beam telescope [9]. Hadronic interactions of a mixed-hadron beam in a fixed target are reconstructed, with the resulting particles combined in 4D track and vertex fits, and the spatial and temporal resolution of the reconstructed vertices is studied. The experimental setup and supporting simulation studies are described in § 2 and § 3, followed by the track and vertex reconstruction procedure in § 4. The spatial and temporal vertex resolutions are presented in § 5 and § 6, respectively, before drawing conclusions in § 7.
Setup
Timepix4 beam telescope
The Timepix4 beam telescope, described in detail in Ref. [9], is based on the Timepix4 ASIC [10] bump bonded to planar silicon sensors. The Timepix4 ASIC consists of a matrix of pixels with a pitch of . Each pixel provides a time-of-arrival (ToA) measurement with a nominal binning of 195 ps and a time-over-threshold (ToT) measurement with 1.56 ns binning. The timing performance of the bare Timepix4 ASIC and bump-bonded assemblies has been extensively characterised in Refs. [11, 12].
The telescope consists of eight Timepix4 planes arranged in two arms each comprising four planes each. A right-handed coordinate system is defined with its origin at the centre of the telescope, the -axis along the beam direction and the -axis pointing upwards. The four outer planes of the telescope are equipped with thick sensors and are positioned perpendicular to the beam to optimise temporal resolution. The four inner planes are equipped with thick sensors and are positioned at an angle of around both the - and -axes to optimise spatial resolution at the telescope centre. The thick planes are therefore referred to as timing planes and the thick planes as spatial planes.
For the studies presented in this paper, the telescope was operated at the CERN H8 beamline [13] with a 180 GeV/ mixed-hadron beam impinging on a fixed target placed upstream of the telescope. Data were collected in July and October 2025 and reconstructed using the Kepler2 software.
Fixed target
A fixed target was installed approximately 12 cm upstream of the front arm to enable vertexing studies. Secondary particles produced in interactions within the target are reconstructed as tracks and combined into vertices. Two target configurations are used: a four-layer tungsten target for the longitudinal spatial resolution measurement, and a single-layer brass target with a slit for the transverse spatial resolution measurement.
The tungsten target consists of four layers of thick tungsten separated by , providing four well-defined interaction planes. The brass target consists of a single thick plate containing a slit of width and length 1 cm. Data were acquired with the slit orientated along either the - or -axis. Both targets are shown in Figure 1.

Figure 1. (a) Tungsten target used for the longitudinal spatial resolution measurement, and (b) brass target with the slit used for the transverse measurement, both shown installed in the beamline (left) and in the laboratory (right).
For the temporal resolution studies, the tungsten target was installed, but vertices from interactions in any upstream material (the plastic scintillators, the target, and the target holder) were used to maximise the size of the data sample.
Time reference system
The telescope is complemented by a time reference system based on two microchannel plate (MCP) detectors, which provide a precise timestamp for each event. Compared with Ref. [9], the system was redesigned for use with the fixed-target setup and to reduce the material budget in the beamline. In the previous downstream configuration, the large angular spread of the secondary particles meant that few traversed the MCPs. Moreover, the MCPs were placed directly in the beamline, degrading the beam quality and limiting the achievable intensity.
The redesigned system consists of two Photonis PP2365Y23 MCPs, each coupled to a quartz Cherenkov radiator of dimensions . The quartz radiators are positioned upstream of the telescope at an angle of approximately to maximise the Cherenkov light yield, while the MCPs are positioned outside the beamline to minimise the material in the beam. Both the quartz radiators and MCPs are enclosed in a light-tight plastic holder. The readout and digitisation of the MCP signals are unchanged from Ref. [9].
The difference between the digitised timestamps of the two MCP signals, as read out from the PicoTDC board, is shown in Figure 2. A Gaussian fit to the distribution yields a standard deviation of 24 ps, corresponding to a time resolution of 17 ps per MCP and 12 ps for the average of the two MCPs (assuming equal performance). This performance matches that of the central peak in Ref. [9]. The secondary peak from hadronic interactions observed with the previous system is greatly reduced owing to the smaller material budget of the quartz radiators. Only events for which the two MCP timestamps agree to within ps are retained for the timing studies.

Figure 2. Difference between the timestamps recorded by the two MCPs. Only events within of the main peak are retained for the timing studies.
Simulation studies
The momentum distribution of secondary particles produced in the fixed-target interactions is characterised using a simulation of the setup implemented in the ALLPIX{sup}2 [14] framework. The telescope and the fixed target, in either of the configurations described in section 2.2, are included in the simulation. Their results are very similar and only those for the tungsten target are presented. Since the beam at the SPS H8 beamline mostly consists of protons, a proton beam with a kinetic energy of 180 GeV is simulated to impinge on the target, and interactions of the beam particles with the material are modelled using the Geant4 [15] software package applying the FTFP_BERT_LIV physics model [16]. Events are retained for analysis if at least two charged particles produced at the vertex pass through the acceptance of the first telescope plane.
The momentum distribution of particles within the acceptance of the first telescope plane is shown in Figure 3a. It is bimodal, with a narrow peak at the beam momentum of 181 GeV/ from primary beam particles undergoing soft interactions, and a broader distribution peaking near 1.5 GeV/ from hard interactions. In practice, only particles from hard interactions are reconstructed, as the low-momentum products of soft interactions are emitted at large angles and fail to traverse the minimum of four planes required for track reconstruction. The resulting track momenta, typically below 50 GeV/, lead to significant multiple scattering. These multiple-scattering effects are incorporated using a Kalman filter–based track fit [17]. The Kalman filter requires an estimate of each track’s momentum to determine the corresponding scattering uncertainty. However, a direct measurement of the momentum is not available, as the telescope does not include a magnetic field. The momentum is therefore estimated from a finely grained 2D histogram of the mean simulated momentum as a function of the track slopes and , shown in Figure 3b, evaluated using the slopes from an initial straight-line fit. All particles are treated as pions, which are found to be the most abundant species in the simulation.
Figure 3. (a) Momentum distribution of simulated particles produced at the vertex and within the acceptance of the first telescope plane. (b) Mean simulated momentum as a function of the track slopes and , used to provide momentum estimates for the Kalman filter–based track fit.
A fast simulation of the telescope, described in Ref. [9], is used to study the expected track pointing resolution at the target position. Straight-line and Kalman filter fits using either four or eight planes are compared for track momenta of 10 GeV/, typical of secondary particles, and 180 GeV/, corresponding to the beam momentum. The results, shown in Figure 4, confirm that the Kalman filter significantly improves the resolution at low momentum, particularly when all eight planes are used, reaching approximately 35 at the target for 10 GeV/ tracks.
Figure 4. Pointing resolution as a function of for tracks of 180 GeV/ and 10 GeV/, reconstructed with a straight-line or Kalman fit using either all eight planes or only the four front planes. The dashed grey line indicates the target position.
Reconstruction
Calibrations
Several calibrations are applied to the raw data from the Timepix4 telescope before reconstruction, including charge calibration, -corrections, and timing corrections. The charge calibration, -corrections, and frequency corrections of the voltage controlled oscillators (VCOs) of the Timepix4 ASIC follow the procedure described in Ref. [9] and are not discussed further.
The timing calibration procedure has been updated for this study. The timewalk correction employed in Ref. [9] used pixel-by-pixel timewalk fits. This method is impractical for this study because the angular spread of the secondary particles illuminates the entire pixel matrix on every plane, requiring a separate calibration for each of the 229 376 pixels on each plane. A neural network–based method, described in detail in Ref. [18], is therefore used and briefly summarised here. Instead of fitting a timewalk function to the measured timewalk for each pixel, a feedforward multilayer perceptron (MLP) is trained to predict the timewalk correction from the charge of the earliest hit in the cluster, the track intercept in the local - and -coordinates of the plane (along columns and rows) relative to the centre of that hit. Compared to [18] the track slopes and have been added as additional input features. With this method, a single MLP is trained for each plane, while pixel-to-pixel variations are absorbed into the per-pixel time offsets. As shown in [18], its performance matches that of pixel-by-pixel timewalk fits for large datasets and exceeds it when the available data are limited.
Track and vertex reconstruction
The track reconstruction is adapted from the standard procedure described in [9] to accommodate the large angular spread of secondary particles produced at the vertex. The requirement on the maximum allowed opening angle between the track and the beam axis is removed. The minimum number of clusters required per track is reduced from eight to four, allowing tracks that traverse only the front arm of the telescope to be retained. The limit on the number of simultaneous clusters per plane is also removed because multiple coincident tracks are expected from fixed-target interactions. Tracks are fitted with the Kalman filter implemented in the Kepler reconstruction framework following [19], which accounts for multiple scattering in the telescope planes. The track fit is seeded using a straight-line fit to the clusters, and the track momentum is estimated from a parametrisation of the mean simulated momentum as a function of the track slopes and , as described in section 3. The track time is included directly in the track state and fitted simultaneously with the spatial position and slopes, using the VCO- and timewalk-corrected cluster times as measurements.
Tracks within 1 ns of one another are combined into vertex candidates by calculating the distance of closest approach (DOCA) for every pair and grouping those with a DOCA below 200 . In this way, vertices containing up to eight tracks are reconstructed from the data sample. The vertex position and time, together with the track slopes at the vertex, are then determined using the iterative least-squares fitting procedure of [20]. As in the track fit, time is included directly in the vertex state and fitted simultaneously with the spatial position and track slopes, using the fitted track states as measurements. The complete procedure therefore constitutes 4D track and vertex fits, rather than a spatial fit to which timing information is added afterwards.
An overview of the standard selection criteria applied to tracks and vertices is given in Table 1.
| Requirement | Default value | Description |
| Clustering | ||
| Time window | 100 ns | Maximum time difference between hits in the same cluster |
| Cluster width in and | Rejects large clusters from -rays, nuclear interactions, etc. | |
| Charge threshold | (timing planes)<br> (spatial planes) | Suppresses noise, optimised per plane |
| Tracking | ||
| Time window | 5 ns | Maximum time difference between clusters to form a track seed (corrected for time of flight) |
| Number of clusters per track | Requires clusters on at least four telescope planes | |
| Fit | Rejects poorly reconstructed tracks | |
| Vertexing | ||
| Time window | 1 ns | Maximum time difference between tracks to form a vertex seed (corrected for time of flight) |
| DOCA | Maximum distance between track pairs to form a vertex seed | |
| Fit | Rejects poorly reconstructed vertices |
Table 1. Standard selection requirements for vertex reconstruction.
The distribution of reconstructed vertices in the - plane for the tungsten target configuration is shown in Figure 5. The four tungsten layers, upstream plastic scintillators, target holder, and downstream Mylar entrance-window foils of the front-arm telescope enclosure are all clearly resolved. The target holder is visible because the beam is not perfectly centred on the target.
Figure 5. Reconstructed vertex distribution in the - plane for the tungsten target, with the resolved structural features annotated on the right.
The distribution of the number of clusters comprising the reconstructed vertex tracks, that is the set of tracks fitted to a single vertex, is shown in Figure 6. Most tracks produced in fixed-target interactions traverse only the front arm of the telescope and therefore contain four clusters, while a smaller fraction traverse the entire telescope and contain eight. Tracks with five to seven clusters traverse the front arm and at least one plane of the back arm, but either leave the telescope acceptance or miss one or more planes because of detector inefficiencies.
Figure 6. Distribution of the number of clusters per track for tracks used to reconstruct vertices.
Spatial resolution
The longitudinal and transverse spatial resolutions are measured using the tungsten and brass targets, respectively. Although tracks within a vertex may contain different numbers of clusters, multiple scattering limits the dependence
of the pointing resolution at the target on the number of clusters in the back arm, as shown in Figure 4. The vertex resolution is therefore expected to depend primarily on the number of tracks rather than the number of clusters per track, and is studied as a function of the vertex track multiplicity .
Longitudinal resolution
The longitudinal spatial resolution is determined using the tungsten target, which provides four clearly defined interaction planes. The distribution of reconstructed vertex positions along the beam axis, , is shown in Figure 7. The four prominent peaks between mm and mm correspond to the four tungsten layers. Two smaller peaks at mm and mm are also visible, corresponding to the Mylar foils covering the entrance window of the front arm enclosure. Only vertices reconstructed within mm mm are considered for the longitudinal resolution measurement. Because the target layers may not be perfectly perpendicular to the -axis, an alignment correction is applied by minimising the measured longitudinal resolution with respect to small rotations of the coordinate frame about all three axes. The rotations are centred on the first target layer. The resulting coordinate is denoted as .
Figure 7. Distribution of reconstructed vertex positions along for the tungsten target, showing four peaks from the tungsten layers and two smaller peaks from the Mylar entrance-window foils.
The longitudinal resolution is extracted for vertex track multiplicities from two to six using unbinned maximum-likelihood fits to the distributions. Each tungsten layer is modelled by a uniform distribution of width centred at , convolved with a Student’s -distribution with mean zero and scale . The number of degrees of freedom, , is fixed to that of the vertex fit. The full signal model is the sum of four such convolutions with a common . The layer thickness is Gaussian-constrained to , and the layer spacings to . The normalisation of each layer and an exponential background, which describes the small contribution from non-tungsten interactions and fake vertices, are free parameters. Example fit results for vertices with two and six tracks are shown in Figure 8.
Figure 8. Fits to the distribution of vertices with (a) two and (b) six tracks.
The extracted longitudinal resolution is shown as a function of the track multiplicity, , in Figure 9. The resolution improves with track multiplicity, reaching for vertices with six tracks. The dependence on track multiplicity is well described by
Figure 9. Longitudinal resolution as a function of , with the best fit to overlaid. The uncertainties shown have been scaled by the Birge ratio .
where the denominator reflects the fact that a single track does not constrain the -position of the vertex. The fit yields with , suggesting that the uncertainties do not fully account for systematic effects. The uncertainties on the measurements shown in Figure 9, and on are therefore scaled by the Birge ratio [21].
The use of a Student’s -distribution rather than a Gaussian is motivated by the imperfect calibration of the track covariances, as such a distribution arises naturally when the variance of an otherwise Gaussian distributed variable is uncertain. Two sources of covariance miscalibration are expected. First, the per-track momentum estimates are derived from a slope parametrisation of the mean momentum rather than direct measurements, introducing uncertainty into the estimated multiple-scattering contributions. Second, each telescope plane has a titanium cooling block on its rear surface with a circular central cutout for the beam. Tracks passing through the corners of a plane therefore traverse more material than those near its centre, but this variation is not included in the track fit. The effect is amplified in , where the small angles between tracks cause modest angular errors to produce large uncertainties in their intersection point.
Transverse resolution
The transverse spatial resolution is studied using the brass target, whose slit provides a sharp edge in the transverse plane. Data were taken with the slit oriented along both the and directions, enabling the resolution to be measured independently in each transverse coordinate. The distribution of reconstructed vertex positions for the -oriented slit is shown in Figure 10, where the slit appears as a band of low vertex density between mm and mm. An alignment procedure analogous to that described in § 5.1 yields calibrated coordinates and . The transverse resolution is then extracted for between two and five using unbinned maximum-likelihood fits.
Figure 10. Vertex distribution in the transverse plane for the brass target with the slit oriented along .
Since the vertex distribution is modulated by the primary beam profile, a kernel density estimate obtained from non-interacting beam tracks is included as a multiplicative term in the fit model. The target slit is modelled as a step function of width centred at , convolved with a Gaussian with standard deviation . The slit width is Gaussian-constrained to mm. To account for a non-uniform geometrical acceptance of the vertices, a linear acceptance term is included, with the slope free in the fit. The full model is thus given by
A uniform background accounts for the small number of vertices reconstructed outside the target and for fake vertices.
Example fits to the distribution for vertices with two and five tracks are shown in Figure 11. An equivalent model is used for the -oriented slit, fitting with resolution parameter , with the fits giving similar results.
Figure 11. Fits to the distribution of vertices with (a) two and (b) five tracks.
The fitted transverse resolutions and are shown as functions of in Figure 12. Both reach approximately for five-track vertices. In contrast to the longitudinal resolution, each track contributes an independent measurement of the transverse vertex position, and the resolution is therefore well described by
Figure 12. Transverse resolutions (a) and (b) as a function of , with best fits to overlaid.
yielding best-fit values of and , with for both fits. The inferred single-track transverse resolutions are somewhat larger than the expected pointing resolution of approximately at the target position shown in Figure 4. This discrepancy is likely caused by the same effects that produce the non-Gaussian tails in the longitudinal vertex distribution. Both the uncertainty in the per-track momentum estimates and the unmodelled material in the corners of the telescope planes degrade the track pointing resolution.
Temporal resolution
The time resolution of the reconstructed vertices is studied using the same tungsten target configuration as for the longitudinal spatial resolution measurement. To increase the size of the data sample, the study includes vertices reconstructed from interactions in all material upstream of the telescope, as shown in Figure 5, rather than only those in the tungsten layers. Throughout this section, time resolutions are defined as the RMS of the central 99 % of the relevant residual distribution with respect to the reference time. The 12 ps contribution from the MCP time reference is subtracted in quadrature.
Single-plane time resolution
The per-plane time residuals for vertex tracks with respect to the MCP time reference are shown in Figure 13 for representative timing and spatial planes. The extracted resolutions are slightly worse than those obtained for isolated beam tracks. The timing-plane resolutions range from 175 ps to 195 ps, compared with 160 ps to 180 ps for beam tracks, while the spatial-plane resolutions are approximately 330 ps, compared with 275 ps. This degradation is largely attributed to the broad angular distribution of the secondary particles, which increases inter-pixel charge sharing and introduces additional timewalk effects that are not fully corrected by the neural network–based calibration. Although the track slopes are included as inputs to the MLP, the training sample is dominated by small-angle isolated beam tracks, so the corrections are less accurate for the large-angle vertex tracks. The pointing resolution at each plane is also degraded for vertex tracks, which further reduces the accuracy of the timewalk corrections via the intrapixel intercept input.
Figure 13. Time residuals with respect to the MCP time reference for a representative (a) timing and (b) spatial plane.
Vertex time resolution
The vertex time resolution is studied as a function of the number of timing-plane clusters, , contributing to the fitted vertex time. This parametrisation is preferred to the vertex track multiplicity because each track may be reconstructed on a different subset of planes. A track confined to the front arm contributes fewer timing measurements than one traversing the full telescope, so vertices with the same track multiplicity may contain substantially different amounts of timing information. Contributions from spatial planes are suppressed by artificially inflating their time resolutions in the track and vertex fits to 10 ns, rendering them effectively weightless in the vertex time fit. For each value of between one and 16, the resolution is extracted from the vertex time residuals with respect to the MCP time reference. Example residual distributions for vertices with four and sixteen timing clusters are shown in Figure 14.
Figure 14. Vertex time residuals with respect to the MCP time reference for vertices with (a) four and (b) sixteen timing clusters.
The resulting vertex time resolution is shown as a function of in Figure 15. It improves with the number of timing-plane clusters, reaching ps for vertices with 16 timing clusters. The resolution is well described by a function of the form
Figure 15. Vertex time resolution as a function of the number of timing-plane clusters , with the best fit to overlaid. The uncertainties shown have been scaled by the Birge ratio .
where is the effective single-plane time resolution and is an irreducible contribution that does not improve with additional timing measurements.
The fit yields and , with . The uncertainties on the vertex time resolutions shown in Figure 9, and on and are therefore scaled by the Birge ratio . The single-plane resolution, , is consistent with the one extracted from the time residuals of the individual planes, showing that timestamps from multiple detector planes and tracks combine according to the expected statistical scaling. The irreducible component, , contains a contribution of less than 15 ps from the jitter in the clock distribution [9]. Additionally, it receives a contribution up to 25 ps due to a positional dependence of timestamp of the time reference system. The time at which the Cherenkov photons reach the MCP depends on the horizontal impact position on the quartz fingers, due to the angle and the time of flight of the photons inside the quartz. Over the width of a Timepix4 ASIC this results in a variation of the average timestamp of approximately 25 ps, which does not appear in the time difference of the two MCP signals. This variation will be reduced since the vertices combine multiple tracks, but is most likely still the main contribution to , besides the clock jitter.
Conclusion
The first demonstration of full 4D vertex reconstruction at the 50 ps scale using a silicon pixel detector system is presented. Hadronic interactions of a mixed-hadron beam were reconstructed with the Timepix4 beam telescope. Cluster time measurements from multiple detector planes were combined in Kalman filter–based track fits, and the fitted track states were subsequently combined into vertices. In all fits, time was included directly in both the track and vertex states and fitted simultaneously with the spatial parameters rather than assigned after spatial reconstruction.
The vertex time resolution was evaluated as a function of the number of timing-plane clusters contributing to the fitted vertex time, after subtracting the known 12 ps contribution from the time reference system. It improves according to the expected statistical scaling, reaching (54 ± 5) ps for vertices with 16 timing clusters. The fitted effective single-plane resolution of (187.9 ± 0.3) ps is consistent with the measured detector performance, showing that the timing measurements combine as expected. An irreducible contribution of (29.2 ± 0.6) ps remains in the fitted resolution model, including large contributions from the clock distribution and from a positional dependence of the time reference system rather than correlations among the timing measurements themselves. Additionally, the spatial resolution of the reconstructed vertices exhibits the expected dependence on the track multiplicity, reaching approximately 20 µm transversely for five-track vertices and 660 µm longitudinally for six-track vertices.
Although no pile-up was present in these measurements, and they do not yet reach the timing performance of 20 ps envisaged for the LHCb Upgrade II, they establish that timestamps form multiple silicon pixel detector planes and tracks can be combined to achieve vertex time resolutions at the 50 ps scale without an unforeseen resolution floor above it. This represents a significant experimental step towards exploiting precision timing for vertex association in future high-pile-up detectors.
Acknowledgements
We thank our colleagues in the CERN accelerator departments for the excellent performance of the beam in the SPS North Area. We thank Miranda van Stenis and Kacper Jama for their help in the preparation of the time reference’s mechanics, and Thierry Gys for his guidance and support during the early stages of operation of the MCP-PMTs. We acknowledge the ASIC designers of Timepix4 and PicoTDC, and the designers of the SPIDR4 readout system. We gratefully acknowledge the computing resources and batch services provided by CERN. We also thank the open-source software communities that supported this work. We acknowledge the CERN EP R&D program’s contribution to the construction of the Timepix4 beam telescope. We also gratefully acknowledge the support from the Netherlands Organisation for Scientific Research (NWO), and the Science and Technology Facilities Council (UK, grant number ST/V003151/1).
References
- [1]LHCb collaboration, LHCb Upgrade II Scoping Document, Technical Report, CERN, Geneva, 2024. URL: https://cds.cern.ch/record/293 บ?DOI
- [2]J. Albrecht, et al., Luminosity scenarios for LHCb Upgrade II, Technical Report, CERN, Geneva, 2019. URL: https://cds.cern.ch/record/2653011.
- [3]LHCb collaboration, Framework TDR for the LHCb Upgrade II, Technical Report, CERN, Geneva, 2021. URL: https://cds.cern.ch/record/2776420. doi:10.17181/CERN.NTVH.Q21W.DOI
- [4]S. Cadeddu, L. Frontini, A. Lai, V. Liberali, L. Piccolo, A. Rivetti, J. Shojaei, A. Stabile, Timespot1: a 28 nm CMOS Pixel Read-Out ASIC for 4D Tracking at High Rates, JINST 18 (2023) P03034. doi:10.1088/1748-0221/18/03/P03034. arXiv:2209.13242.
- [5]P. Albicocco, et al., Results and perspectives of the IGNITE project on the development of CMOS 28 nm technology ASICs, JINST 21 (2026) C08004. doi:10.1088/1748-0221/21/08/C08004.DOI
- [6]F. Borgato, et al., Characterisation of highly irradiated 3D trench silicon pixel sensors for 4D tracking with 10 ps timing accuracy, Front. in Phys. 12 (2024) 1393019. doi:10.3389/fphy.2024.1393019.DOI
- [7]A. Lampis, et al., 10 ps timing with highly irradiated 3D trench silicon pixel sensors, JINST 18 (2023) C01051. doi:10.1088/1748-0221/18/01/C01051. arXiv:2209.14632.DOI
- [8]G. Aglieri Rinella, et al., The NA62 GigaTracKer: a low mass high intensity beam 4D tracker with 65 ps time resolution on tracks, JINST 14 (2019) P07010. doi:10.1088/1748-0221/14/07/P07010. arXiv:1904.12837.DOI
- [9]K. Akiba, et al., The Timepix4 beam telescope, Nucl. Instrum. Meth. A1084 (2026) 171234. doi:10.1016/j.nima.2025.171234. arXiv:2503.15207.DOI
- [10]X. Lopart, et al., Timepix4, a large area pixel detector readout chip which can be tiled on 4 sides providing sub-200 ps timestamp binning, JINST 17 (2022) C01044. doi:10.1088/1748-0221/17/01/C01044.
- [11]K. Heijhoff, et al., Timing performance of the Timepix4 front-end, JINST 17 (2022) P07006. doi:10.1088/1748-0221/17/07/p07006. arXiv:2203.15912.DOI
- [12]R. Bolzonella, et al., Timing resolution performance of Timepix4 bump-bonded assemblies, JINST 19 (2024) P07021. doi:10.1088/1748-0221/19/07/P07021. arXiv:2404.15499.DOI
- [13]CERN Engineering Department, The H8 Secondary Beam Line of EHN1/SPS, 2019. URL: https://sba.web.cern.ch/sba/BeamsAndAreas/H8/H8_presentation.html.
- [14]S. Spannagel, P. Schütze, Allpix2 — silicon detector monte carlo simulations for particle physics and beyond, JINST 17 (2022) C09024. URL: http://dx.doi.org/10.1088/1748-0221/17/09/C09024. doi:10.1088/1748-0221/17/09/c09024.
- [15]J. Allison, et al. (Geant4 collaboration), Geant4 developments and applications, IEEE Trans.Nucl.Sci. 53 (2006) 270. doi:10.1109/TNS.2006.869826.DOI
- [16]J. Allison, et al. (Geant4 collaboration), Recent developments in Geant4, Nucl. Instrum. Meth. A835 (2016) 186–225. doi:10.1016/j.nima.2016.06.125.DOI
- [17]R. E. Kalman, A New Approach to Linear Filtering and Prediction Problems, J. Fluids Eng. 82 (1960) 35–45. doi:10.1115/1.3662552.DOI
- [18]D. Bacher, et al., Neural network-based timewalk correction for the Timepix4 ASIC (2026). arXiv:2610.10328, submitted to JINST.arxiv.org/abs/2610.10328
- [19]R. Fruhwirth, Application of Kalman filtering to track and vertex fitting, Nucl. Instrum. Meth. A262 (1987) 444–450. doi:10.1016/0168-9002(87)90887-4.DOI
- [20]A. Strandie, R. Frühwirth, Track and vertex reconstruction: From classical to adaptive methods, Rev. Mod. Phys. 82 (2010) 1419–1458. doi:10.1103/RevModPhys.82.1419.DOI
- [21]R. T. Birge, The Calculation of Errors by the Method of Least Squares, Phys. Rev. 40 (1932) 207. doi:10.1103/PhysRev.40.207.DOI