betaFeedback

WorksPhysics and Astronomy

Phonon-laser ultrasensitive force sensor

Abstract

Developing nano-mechanical oscillators for ultrasensitive force detection is of great importance in exploring science. We report our achievement of ultrasensitive detection of the external force regarding the radio-frequency electric field by a nano-sensor made of a single trapped 40^{40}Ca+^{+} ion under injection-locking, where squeezing is additionally applied to detection of the smallest force in the ion trap. The employed ion is confined stably in a surface electrode trap and works as a phonon laser that is very sensitive to the external disturbance. The injection-locking drove the ion's oscillation with phase synchronization, yielding the force detection with sensitivity of 347 ±\pm 50 yN/Hz\sqrt{Hz}. Further with 3 dB squeezing applied on the oscillation phase variance, we achieved a successful detection of the smallest force to be 86.5 ±\pm 70.1 yN.

INTRODUCTION

With development of nanotechnology using atomic and molecular sensors, the physical quantities have been detected in a higher level of sensitivity than ever before due to the excellent perceived performance of the sensors [1, 2, 3, 4, 5, 6, 7, 8]. Force detection has been always taking an important role in precision measurement since all the changes of motion are concerned with the force due to Newton’s laws, where the small force detection by trapped ions or atoms has recently demonstrated the superiority of high sensitivity and broad adjustability [9, 10, 11, 12, 13, 14, 15, 16]. The weak AC electric force was sensitively detected by means of spin-motion entanglement in two-dimensional trapped-ion mechanical oscillators [9, 10, 11]. The radio-frequency electric force as small as 5 yN was measured, based on the technique of injection-locked phonon laser, by observing the range of injected frequency and the gravity variance of the ion’s displacement [12]. Such a radio-frequency electric force was also detected by phase-coherent Doppler velocimetry, reaching the sensitivity of 390 ±\pm 150 yN/Hz\sqrt{\mathrm{Hz}} [13]. A recent detection of the sub-attonewton force regarding DC electric field was accomplished by measuring the ion’s displacement three-dimensionally at a nanometer precision [15].

In the present work, we report our ultrasensitive detection of the radio-frequency electric force at hundred yoctonewton’s order of magnitude by a nano-probe made of a single trapped 40Ca+{}^{40}\mathrm{Ca}^{+} ion. Although our detection, similar to in [12], also takes advantage of the stably confined ion behaving as a phonon laser, we acquired the sensitivity of the sensor and the lower bound of the small force by faster measurements compared to the method of scanning the injection frequency in [12]. In addition, squeezing technique [17] was employed to further suppress thermal noises in the system. The ion’s phonon laser under our consideration works as an amplitude-amplified harmonic oscillator, which is quite sensitive to the external force, as reported previously [18, 19, 20, 21, 22, 23]. In our experiment, the trapped 40Ca+{}^{40}\mathrm{Ca}^{+} ion was first Doppler-cooled and then pumped simultaneously by a red-detuned laser and a blue-detuned laser with respect to the resonant transition. After locking the oscillation frequency by injection signal, we might detect the injected force, which is induced by a radio-frequency electric field, based on the photon count measurements of the oscillation amplitude, the latter of which was carried out by fitting the fluorescence curve directly acquired from the photomultiplier tube (PMT) along with the synchronized measurement of the injection-locking signal. Our achieved force sensitivity is as low as 347 ±\pm 50 yN/Hz\sqrt{\mathrm{Hz}}, and the oscillation amplitude uncertainty is only 15 nm with respect to the oscillation amplitude ≈\approx18 μ\mum. The detection sensitivity represents the minimum detectable change rate of the force. In contrast, we may also try to detect the smallest force, indicating the minimum force our probe could sense. To this end, we introduce the squeezing technique as in [17] and with 3 dB squeezing applied on the oscillation phase variance, we detected successfully the smallest force of 86.5 ±\pm 70.1 yN. Our technique could be applied to the oscillation force sensors using other ions, atoms or solid-state oscillators.

EXPERIMENTAL SYSTEM AND SCHEME

Our experiment of ultrasensitive force detection is carried out by an injection-locked phonon laser regarding a single trapped ion confined stably in the harmonic potential of a surface-electrode trap (SET), see Figure 1a. The SET employed in our experiment was introduced previously [24, 25, 26, 27], which is a 500-μ\mum scale planar trap composed of two pairs of endcap electrodes, two pairs of steering electrodes, a pair of middle electrodes, an axial electrode and a radio-frequency electrode. The measured secular frequencies of the SET are, respectively, ωz/2π=186.02±0.01 kHz\omega_z/2\pi= 186.02\pm0.01\ \mathrm{kHz}, ωx/2π=680.4±0.1 kHz\omega_x/2\pi= 680.4\pm0.1\ \mathrm{kHz}, and ωy/2π=1020.3±0.5 kHz\omega_y/2\pi= 1020.3\pm0.5\ \mathrm{kHz}. The 40Ca+^{40}\mathrm{Ca}^{+} ions, when confined stably in the potential, stay with 800 μm\mu\mathrm{m} above the surface of the SET.

Image not extracted

Figure 1. Experimental system and scheme. (a) Sketch of the phonon laser of an ion trapped above the surface of the SET. The 40Ca+^{40}\mathrm{Ca}^{+} ion with oscillating motion irradiated by red- and blue-detuned 397-nm laser beams is trapped by the potential Ψ(t)\Psi(t) regarding a time-varying electric field. The electrodes are labelled with names for convenience of description in the text, where EE, SE, ME, AE and RF indicate, respectively, the endcap electrode, the steering electrode, the middle electrode, the axial electrode and the radio-frequency electrode. The injection signal applied on AE with frequency ωi=ωz\omega_i = \omega_z, locking the oscillation frequency, is to be detected. The squeezing, with frequency doubling of ωi\omega_i, acts on EEs when required. The top-right inset is the level scheme of 40Ca+^{40}\mathrm{Ca}^{+} for our purpose. (b) Signal processing scheme of the photon-arrival-time measurements. The applied injection signal and the squeezing signal are phase synchronized, with the latter of frequency doubling with respect to the former. The photon-arrival-time transited to voltage is measured by TAC. The ratio of the beam splitter for the PMT to CCD is set to be 7/3. (c) Signal and sequence diagram. The Injection signal contributes to locking the oscillation frequency/phase. The Squeezing signal is applied, when required, to suppress the variance of the oscillation phase. The Gate signal controls the measurement time tmt_m containing a series of oscillation period TT and the TAC records the photon’s arrival time tt in each period. The Start signal comes from the PMT regarding the photon pulses. The Stop TTL is synchronized with injection locking signal and the Stop signal is produced by the photon pulses from the spontaneous emission. For clarity, the plotted pulses are not strictly to scale. The typical values: tm=10 st_m = 10\ \mathrm{s}, T=5.38 μsT = 5.38\ \mu\mathrm{s}, and 0<t≤T0 < t \leq T.

The phonon laser is produced by the oscillation amplification of the single 40Ca+^{40}\mathrm{Ca}^{+} ion stimulated by two 397 nm laser beams, one of which is a red-detuned beam with detuning Δ1/2π=−75 MHz\Delta_1/2\pi= -75\ \mathrm{MHz} and the other of which is a blue-detuned beam with Δ2/2π=30 MHz\Delta_2/2\pi= 30\ \mathrm{MHz}. Both of the laser beams are elaborately tuned to be with the appropriate intensity ratio r=Ib/Ir=0.5r = I_b/I_r = 0.5 (Ir=370 W/m2I_r = 370\ \mathrm{W}/\mathrm{m}^2 and Ib=175 W/m2I_b = 175\ \mathrm{W}/\mathrm{m}^2) in order to keep the oscillation amplification stable [18], which yields the phonon laser with the oscillation amplitude of 17.839 μm\mu\mathrm{m}. Besides, we have a saturated 866 nm laser for repumping, as sketched in Figure 1a. Since the decay from P1/2P_{1/2} to S1/2S_{1/2} is much larger than that from P1/2P_{1/2} to D3/2D_{3/2}, the three-level system could be reasonably considered as a two-level system [28].

In our system, we may produce the phonon laser solely regarding the zz-axis motional degree of freedom of the ion due to the large frequency differences in different directions. Due to the same reason, we may lock the phonon laser’s oscillation frequency to ωz\omega_z, i.e., the trap frequency along zz axis, by applying an appropriate injection-locking signal to AE, which has no influence on other two directions. Generally speaking, when the injection frequency ωi\omega_i is tuned to the locking range, the phonon laser’s oscillation frequency would be fixed at ωi\omega_i with a very sharp bandwidth [12], implying that the oscillation phase φ\varphi, rather than the oscillation amplitude AA, is also locked. In this case, we describe the injection force simply as F0sin⁡(ωit)F_0\sin(\omega_i t), where F0F_0 is the force amplitude to be detected.

The main operations of our experiment are controlled by the injection and/or squeezing signal processing system, as sketched in Figure 1b. The time-to-amplitude converter (TAC) gets started from the transistor-transistor logic (TTL) signal of the photon pulses via PMT and ended at the synchronized TTL signal of the injection. The time resolution of the TAC trt_r is 10 ns, which fully satisfies the requirements of the present experiment. The phonon laser is observed from the charge-coupled-device (CCD), see the images in Figure 1a. With the locking signal applied, we may observe the oscillation of the phonon laser amplifying in an approximately linear way, implying that the injection locking takes action. To acquire the values of the phase φ\varphi and the amplitude AA of the oscillation, we locked the oscillation frequency of the phonon laser, and recorded the accumulated photon counts within each measurement time tmt_m, as indicated in Figure 1c.

Fitting method

For our purpose, we have developed an approach to fast acquire the value of AA by fitting the recorded photons. To this end, we assume that φ\varphi and AA are constants in tmt_m by ignoring the short-time noise. Under the irradiation of the 397-nm laser beams, the scattering rate ρj\rho_j at time tt is given by [29],

ρj(t)=Γsj/(4π)1+sj+4[Δj−kjωiAcos⁡(ωit+φ)Γ]2(1)\rho_j(t)=\frac{\Gamma s_j/(4\pi)}{1+s_j+4\left[\frac{\Delta_j-k_j\omega_i A\cos(\omega_i t+\varphi)}{\Gamma}\right]^2} \tag*{(1)}

where Γ\Gamma is the decay rate of P1/2P_{1/2}, kjk_j is the wave vector, Δj\Delta_j means the detuning and sjs_j represents the saturation parameter. Due to two 397-nm laser beams with different detunings in our experiment, the total scattering rate ρ(t)=ρ1(t)+ρ2(t)\rho(t)=\rho_1(t)+\rho_2(t). To fit the experimental photon counts, we involved the noise, such as the projection noise, the laser power noise and etc, for which the Gaussian term G(t)G(t) is introduced in fitting the curve of P(t)P(t) by a convolution function,

P(t)=αρ(t)∗G(t)+β(2)P(t)=\alpha\rho(t)*G(t)+\beta \tag*{(2)}

where G(t)=(1/2πσt)exp⁡[−t2/(2σt2)]G(t)=(1/\sqrt{2\pi\sigma_t})\exp[-t^2/(2\sigma_t^2)] with σt\sigma_t the degree of time dispersion. α\alpha and β\beta represent the factors regarding the measurement time tmt_m, the fluorescence collection efficiency η\eta, the background photons and the number of unit time intervals nn as well as the signal-to-noise ratio (SNR) relevant to the background light. More details about the fitting can be found in Appendix.

Figure 2 presents two fitting curves with respect to the experimental data under different injection voltages ViV_i. From the fitting, we acquired the oscillation amplitude AA and phase φ\varphi as constants. We observed that tuning φ\varphi mainly changes the position of the curve in the horizontal axis of tt and varying AA mainly influences the height of the second peak of the curve. This indicates that AA and φ\varphi are mutually independent and thus can be acquired simultaneously by the fitting.

Image not extracted

Figure 2. Typical fitting cases for the accumulated photon counts. (a) A=21.677 μmA=21.677\ \mu\mathrm{m} and φ=0.028\varphi=0.028 are obtained under the injection voltage Vi=9.5 mVV_i=9.5\ \mathrm{mV}. (b) A=24.462 μmA=24.462\ \mu\mathrm{m} and φ=0.042\varphi=0.042 are acquired under the injection voltage Vi=18.25 mVV_i=18.25\ \mathrm{mV}. The dots are experimental data and solid curves are fitted by Eq. (2). Total photon counts N=5.353×104N=5.353\times10^4 are recorded within 538 unit time intervals, where each measurement time is tm=10 st_m=10\ \mathrm{s} and we set the parameter values as σt=80tr=0.8 μs\sigma_t=80t_r=0.8\ \mu\mathrm{s}, α=4×10−5\alpha=4\times10^{-5} and β=46\beta=46.

Results and discussion

Force sensing

The force calibration is needed prior to the force sensing due to the fact that the injection force F0F_0 sensed by the ion originates from a radio-frequency voltage ViV_i on AE applied by the injection-locking signal and F0F_0 should be evaluated by comparing with the counterpart regarding a DC voltage on AE. For the latter, we have the static force Fc=mωz2zF_c=m\omega_z^2 z with zz the position deviation of the ion due to the applied DC voltage. In our experiment, we have measured z=12 μmz=12\ \mu\mathrm{m} when the applied DC voltage is 3 V, implying the force Fc=1088.5F_c=1088.5 zN. Thus we obtained the slope ∂Fc/∂Vi=362.8\partial F_c/\partial V_i=362.8 yN/mV.

For a harmonic oscillator, such as the trapped ion, however, the oscillation amplitude variation due to the applied radio-frequency voltage ViV_i of the injection signal originates from the resonance absorption of the energy. But we may reasonably consider the amplitude variation to be driven by the force F0F_0 by assuming F0=FcF_0=F_c. Since the oscillation amplitude AA can be accurately measured, as discussed above, by fitting the fluorescence curve when the oscillation frequency is locked, we obtained a linear relationship between the injection voltage ViV_i and the oscillation amplitude AA, with the slope ∂A/∂Vi=362.1 nm/mV\partial A/\partial V_i = 362.1\ \mathrm{nm/mV}, see Figure 3a. Excluding the original oscillation amplitude without injection, i.e., 17.839 μm17.839\ \mathrm{\mu m}, we found the relationship between the injection force and the oscillation amplitude as ∂A/∂F0=0.9979 nm/yN\partial A/\partial F_0 = 0.9979\ \mathrm{nm/yN}. Due to frequency drifts, the measured secular frequency along zz axis is ωz/2π=186.02±0.01 kHz\omega_z/2\pi= 186.02 \pm0.01\ \mathrm{kHz}, which yields the uncertainty of the measured oscillation amplitude to be 15±2 nm15 \pm2\ \mathrm{nm} regarding ViV_i. Therefore, the sensitivity of our force sensor is 347±50 yN/Hz347 \pm50\ \mathrm{yN}/\sqrt{\mathrm{Hz}}.

Image not extracted

Figure 3. Detection sensitivity and smallest force measurement. (a) Oscillation amplitude as a function of the injection voltage, where the red dot represent the case without the injection voltage and the blue dots are experimental data. (b) Relative variance as a function of gg in the case of ϕ=π/2\phi= \pi/2. (c) Relative variance as a function of ϕ\phi in the case of g=0.9g = 0.9. In (b,c) the variance without squeezing is normalized as unit, as represented by the dashed lines. (d) Experimental results of the lower bound of the force detection, where the blue dots are experimental data without squeezing and the red dots with 3 dB squeezing. The horizontal axis is with log⁡10\log_{10} scale for distinguishing the difference due to the applied squeezing. The values of force and amplitude variation are identified from the measured injection voltage, following the linear relationship in the text. In all the panels, the voltage regarding the injection signal is 18.25 mV. Further voltage of 125 mV is applied on the EEs to generate 3 dB squeezing. Each measurement takes 10 seconds and we make 50 measurements for each data point.

Squeezing

Squeezing is an effective way to reduce the noises in precision measurement [17, 30, 31, 32, 33]. In our experiment, we try to further improve the measurement precision by employing the approach of squeezing to suppress thermal noises regarding the oscillator, as explored in [17]. Compared to the quantum mechanical squeezing to suppress quantum noises for beating standard quantum limit, the squeezing employed here is the classical squeezing, which reduces the effect of thermal noise by redistributing the thermal fluctuations. Since this squeezing is produced also by doubling the motional frequency, similar to the quantum counterpart, we may simply call it squeezing here. In our case with the Doppler-cooled ion, this squeezing helps us improve the precision of detection in the measurement of the smallest force.

The squeezing signal is applied on the EEs with frequency doubling and synchronizing with respect to the injection signal. So only the motion along zz axis could feel the squeezing effect. Mathematically, the uncertainty of the oscillation can be expressed by the measured standard deviation of AA and φ\varphi, i.e., σX=σA\sigma_X = \sigma_A and σY=A0σφ\sigma_Y = A_0\sigma_\varphi, where A0A_0 is the oscillation amplitude in the absence of noises. By ignoring the second-order terms in derivative as well as the higher-order terms of frequency, we acquired the variance of Y(t)Y(t) as [30, 31],

σY2(g,φ)=σY2(0)1−gcos⁡(2φ),(3)\sigma_Y^2(g,\varphi) = \frac{\sigma_Y^2(0)}{1-g\cos(2\varphi)}, \tag*{(3)}

where σY2(0)\sigma_Y^2(0) means the variance without squeezing and gg is relevant to the trapping potential modification regarding the squeezing signal (see Appendix for details).

We focus on the variance of the oscillation phase below since we have only locked the oscillation phase, rather than the oscillation amplitude. Squeezing the variance of the phase requires reducing gcos⁡(2φ)g\cos(2\varphi), as indicated in Eq. (3), which is achieved by tuning gg and φ\varphi, respectively. Figure 3(b,Figure 3c) present the relative variance σY2(g,φ)/σY2(0)\sigma_Y^2(g,\varphi)/\sigma_Y^2(0) as functions of gg and φ\varphi, where the red solid curves represent the theoretical simulation using Eq. (3) and the blue dots are the experimental results with each dot acquired by 50 measurements. From the results, we identified the best squeezing effects occurred at 3 dB when gcos⁡(2φ)=1g\cos(2\varphi) = 1.

In our experiment, we have observed the effect of squeezing on the oscillation phase, rather than the oscillation amplitude. This is due to the fact that the squeezing is relevant to the injection-locking we applied, which fixed the phase, but not the amplitude. Compared to the frequency/phase locking, locking amplitude is more challenging in ion-trap systems. For example, the feedback-locking is in principle available to fix the oscillation amplitude, but hard to achieve using current techniques since it requires higher scattering rate and higher fluorescence collection efficiency. Nevertheless, with only frequency/phase locked, we are able to reach the lower bound in the force detection, as elucidated below.

Lower bound of force detection

To detect the smallest force, we may reduce the injection voltage ViV_i until the phonon laser is unlocked, which is judged by fitting the values regarding the variation of the phonon laser’s oscillation amplitude with respect to the voltage. Qualitatively, we identify the phonon laser working in a critical point when the oscillation frequency is locked with success probability of 90%. This implies the failure of the force detection once the locking probability is lower than 90%. By this way, we have detected in the absence of squeezing the critical voltage of 0.3 mV, corresponding to the lower bound of the detectable force as 171.7±74.3171.7 \pm74.3 yN, where the large uncertainty comes from the very weak locking at the critical point and can be resorted to the error bars, as marked in Figure 3(d). While with 3 dB squeezing applied, the lower bound goes further down to 86.5±70.186.5 \pm70.1 yN due to the successful reach of the critical voltage of 0.15 mV, where the uncertainty is also reduced due to squeezing. Since 3 dB is the best squeezing value in our experiment, we consider this lower bound to be the smallest force we can detect.

Note that, the smallest force detection in our method is determined by the frequency locking and squeezing. Repetition of measurement just helps reducing the detection uncertainty, but irrelevant to the lower bound. In this context, we have measured the electric noise on the electrodes for further understanding of the force detection lower bound. We found that the electric noise is approximately 2 mV. This fact explains the lower bound we have reached in our force detection, that is, the injection voltage could be sensed by the phonon laser only when larger than 15% (8%) of the total electric noise in the absence (presence) of squeezing. This indicates that, besides reducing the measurement variance, the squeezing also improves the signal detection from the electric noise, favoring the sensing of the smaller force. In this context, to further detect a smaller force, we will have to optimize our method by suppressing the electric noises. Besides, reducing the frequency drift would be another important effort in the future. We have found that the frequency ωz\omega_z drifts for about 10 Hz during each measurement of 500 s. Since the locking range is really narrow, the frequency drift has the strong influence on the smallest force detection which occurs at the critical point of the frequency locking.

Conclusion

In summary, we have demonstrated experimentally an ultrasensitive force sensor of the phonon laser of a trapped ion, where injection-locking favors high sensitivity of force detection and squeezing helps for detecting the smallest force. Our implementation worked without the prerequisite of sideband cooling, but efficiently suppressed thermal noises in the detection of the smallest force. Besides, we developed a fast approach to measure the oscillation amplitude based on counting the emitted photons. By this way, without the help of the phase Fresnel lens as employed in [15], our force detection by means of detecting the oscillation amplitude variation of the phonon laser is more sensitive to the external disturbance than by detecting the ion’s position deviation. In this context, we anticipate that our scheme could be further optimized to achieve the force detection with better sensitivity in the case of higher fluorescence collection efficiency, lighter ion probe and lower electric noise. Further efforts in the future would be to suppress the secular frequency drift resulted from the electrodes’ voltage drift and lock the oscillation amplitude of the phonon laser. Our employed technique can also be generalized to precisely detecting the force gradient and the surface noise due to electric fluctuation.

Acknowledgments

This work was supported by Key Research & Development Project of Guangdong Province under Grant No. 2020B0303330001, by National Key Research & Development Program of China under grant No. 2017YFA0304503, and by National Natural Science Foundation of China under Grant Nos. 12074346, 12074390, 11835011, 11804375, 11804308, 91421111, 11734018.

Zhichao Liu and Yaqi Wei contributed equally to this work.

Dynamics

For a harmonic oscillator with the oscillation frequency ω\omega under perturbation of the thermal noise, the motion is described as z(t)=[A0+δA(t)]sin⁡[ωt+δφ(t)]z(t) = [A_0 + \delta_A(t)]\sin[\omega t + \delta_\varphi(t)], which can be rewritten as [17],

z(t)=X(t)sin⁡(ωt)+Y(t)cos⁡(ωt),(4)z(t) = X(t)\sin(\omega t) + Y(t)\cos(\omega t), \tag*{(4)}

with two orthogonal components X(t)=A0+δA(t)X(t) = A_0 + \delta_A(t) and Y(t)=A0δφ(t)Y(t) = A_0\delta_\varphi(t). In the varying electric field, the trap secular frequency ωz\omega_z in our experiment is given by

ωz2=Qm∂2ψ(z)∂z2,(5)\omega_z^2 = \frac{Q}{m}\frac{\partial^2\psi(z)}{\partial z^2}, \tag*{(5)}

where Q/mQ/m is the charge-to-mass ratio of 40Ca+{}^{40}\mathrm{Ca}^{+} ion and ψ(z)\psi(z) is the potential along zz axis without squeezing.

When the classical squeezing is on, the squeezing with frequency 2ωi2\omega_i would modify the original potential, meaning ψ(z)[1+g0sin⁡(2ωit+2ϕ)]\psi(z)[1+g_0\sin(2\omega_i t+2\phi)], where g0g_0 is the assumed gain and ϕ\phi is the relative phase with respect to the injection signal. In this case, the trap frequency is rewritten as ωs2(t)=ωz2[1+g0sin⁡(2ωit+2ϕ)]\omega_s^2(t)=\omega_z^2[1+g_0\sin(2\omega_i t+2\phi)]. For convenience of calculation, we assume g0=gζ/ωzg_0=g\zeta/\omega_z, where gg is dimensionless and g≥0g\geq0, and ζ\zeta is the frictional damping. Considering two 397 nm laser beams, we have the total frictional damping ζ=ζ1+ζ2\zeta=\zeta_1+\zeta_2 with the mathematical expression as [29],

ζj=−4ℏkj2Δj/Γ[1+sj+4(Δj/Γ)2]2,(6)\zeta_j=-\frac{4\hbar k_j^2\Delta_j/\Gamma}{[1+s_j+4(\Delta_j/\Gamma)^2]^2}, \tag*{(6)}

where kjk_j, Δj\Delta_j and sjs_j are, respectively, the wave number, detuning and saturation parameter of the jjth beam of the 397-nm laser.

As the oscillation frequency of the phonon laser is locked and the squeezing is on, we have ω=ωi\omega=\omega_i and then the Langevin equation is given by [36],

z¨(t)+ζz˙(t)+[ωz2+gζωzsin⁡(2ωit+2ϕ)]z(t)=F(t)+fn(t)m,(7)\ddot{z}(t)+\zeta\dot{z}(t)+[\omega_z^2+g\zeta\omega_z\sin(2\omega_i t+2\phi)]z(t)=\frac{F(t)+f_n(t)}{m}, \tag*{(7)}

where the random force by thermal noise is fn(t)=fy(t)sin⁡(ωit)+fx(t)cos⁡(ωit)f_n(t)=f_y(t)\sin(\omega_i t)+f_x(t)\cos(\omega_i t) and the injection force is F(t)=F0sin⁡(ωit)F(t)=F_0\sin(\omega_i t). When the oscillation frequency is locked, we have ω=ωi\omega=\omega_i. Rewriting Eq. (A4) by two orthogonal components X(t)sin⁡(ωit)X(t)\sin(\omega_i t) and Y(t)cos⁡(ωit)Y(t)\cos(\omega_i t), we obtain,

X˙(t)+ζ2(1+gcos⁡(2ϕ))X(t)=fx(t)2ωz,(8)\dot{X}(t)+\frac{\zeta}{2}(1+g\cos(2\phi))X(t)=\frac{f_x(t)}{2\omega_z}, \tag*{(8)}
Y˙(t)+ζ2(1−gcos⁡(2ϕ))Y(t)=F0+fy(t)2ωz,(9)\dot{Y}(t)+\frac{\zeta}{2}(1-g\cos(2\phi))Y(t)=\frac{F_0+f_y(t)}{2\omega_z}, \tag*{(9)}

where the second-order terms and ’ωit\omega_i t’ terms are neglected. Thus the variances of X(t)X(t) and Y(t)Y(t) related to temperature are σX2(0)=σY2(0)=kBT2mωz2\sigma_X^2(0)=\sigma_Y^2(0)=\frac{k_B T}{2m\omega_z^2} [30]. In our experiment, we just focus on Y(t)Y(t), whose variance with the squeezing gain gg can be written as in Eq. (3) [31].

From Eq. (4), we have σY=A0σφ\sigma_Y=A_0\sigma_\varphi, where σφ\sigma_\varphi is the uncertainty of the oscillation phase. Therefore, we obtain σφ2(g,ϕ)/σφ2(0)=1/[1−gcos⁡(2ϕ)]\sigma_\varphi^2(g,\phi)/\sigma_\varphi^2(0)=1/[1-g\cos(2\phi)]. In the case of 0<gcos⁡(2ϕ)<10<g\cos(2\phi)<1, the uncertainty increases, whereas for −1<gcos⁡(2ϕ)<0-1<g\cos(2\phi)<0, the uncertainty reduces. We have observed experimentally that the best squeezing is 3 dB, which occurs in g→1g\to1 and ϕ=π/2\phi=\pi/2.

Appendix B: Fluorescence collection efficiency

Improving the fluorescence collection efficiency of the force sensor is an important technique to achieve higher sensitivity. In our experiment, the numerical aperture of the imaging lens set is 0.36 and the transmittance is 80%. The transfer efficiency of the photons by PMT is 23% and only 70% light goes through the beam splitter mirror. There are other factors in our system for the light loss of 12%. For the phonon laser, the TAC transfer efficiency of the PMT pulses to TTL is about 66%. Therefore, the total fluorescence collection efficiency η\eta is about 0.25% in theoretical prediction, which basically agrees with the measurement result 0.28%. The SNR is about 2.0 and the background noise is mainly from the diffuse reflection of the two 397-nm laser beams.

The efficiency is an important factor for sensitivity. With high efficiency, the total measurement time τ\tau could be shorten, where τ\tau can be written as the product of the single measurement time tmt_m and the measurement repetition ϵ\epsilon, namely τ=ϵtm\tau=\epsilon t_m. In our experiment, ϵ=50\epsilon=50 and tm=10 st_m=10\ \mathrm{s}. Therefore, the sensitivity is given by [37],

S=δAτ∂A/∂F0,(10)S=\frac{\delta A\sqrt{\tau}}{\partial A/\partial F_0}, \tag*{(10)}

where δA\delta A is the standard deviation of the measured oscillation amplitude. In our experiment, we have ∂A/∂F0=0.9979 nm/yN\partial A/\partial F_0=0.9979\ \mathrm{nm/yN} and δA=15 nm\delta A=15\ \mathrm{nm}, so that the sensitivity is 347 yN/Hz\sqrt{\mathrm{Hz}}, which could be improved by lowering the total measurement time τ\tau, i.e., enhancing the fluorescence collection efficiency.

Appendix C: Drift of the secular frequency

When the oscillation frequency ω\omega of the phonon laser is locked to the injection frequency ωi\omega_i, i.e., ω=ωi\omega=\omega_i, the bandwidth of the oscillation frequency turns to be very sharp. The locking range ωm\omega_m is approximately in linear proportion to the injection force F0F_0 and the central frequency of the locking range is exactly the secular frequency ωz\omega_z [12]. However, there exist drifts of the voltages applied on the electrodes, which lead to the secular frequency drifts. We have observed experimentally the drift of the frequency for about 10 Hz per 500 s. This drift has strong influence on the smallest force detection which occurs at the critical point of the frequency locking. Further suppression of such drifts would make a smaller force detection available.

Appendix D: Fitting parameters

Before acquiring the oscillation amplitude AA and phase φ\varphi by fitting experimental data, we need to determine other parameters. The detunings of the 397-nm laser beams can be adjusted by acoustic optical modulators, and the resonant frequency is obtained by the Lorentzian curve [34, 35]. The densities of the 397-nm laser beams are directly measured by saturation spectra, which are s1=0.8s_1=0.8 and s2=0.4s_2=0.4 in our experiment. The wave vectors are approximately considered as k1≈k2≈kk_1\approx k_2\approx k, related to the resonant frequency 755.22 THz. The decay rate is Γ/2π=20.68\Gamma/2\pi=20.68 MHz.

Other three parameters α\alpha, β\beta and σt\sigma_t are obtained by the fitting. We set σt=0.8 μs\sigma_t=0.8\ \mu\mathrm{s} in terms of the system’s noise, and observed the oscillation amplitude 22 μm22\ \mu\mathrm{m} of the phonon laser. The emitted photons are theoretically 1.271×1071.271 \times10^{7} within 10 seconds, while the experimentally collected photon count NN is 5.353×1045.353 \times10^{4}. Since the SNR is about 2.0, we have η\eta to be 0.28%. Then we acquired the values of α\alpha and β\beta by α=ηtm/n\alpha= \eta t_{\mathrm{m}}/n and β=N/[n(1+SNR)]\beta= N/[n(1+\mathrm{SNR})], which led to the values of AA and φ\varphi.

References

References

  1. [1]O. Hosten, N. J. Engelsen, R. Krishnakumar, M. A. Kasevich, Measurement noise 100 times lower than the quantum-projection limit using entangled atoms. Nature 529, 505-508 (2016).
  2. [2]S. Schreppler, N. Spethmann, N. Brahms, T. Botter, M. Barrios, D. M. Stamper-Kurn, Optically measuring force near the standard quantum limit. Science 344, 1486-1489 (2019).
  3. [3]H. J. Mamin, D. Rugar, Sub-attonewton force detection at millikelvin temperatures. Appl. Phys. Lett. 79, 3358 (2001).DOI
  4. [4]F. Lecocq, J. B. Clark, R. W. Simmonds, J. Aumentado, J. D. Teufel, Quantum nondemolition measurement of a nonclassical state of a massive object. Phys. Rev. X 5, 041037 (2001).
  5. [5]C. M. Caves, Quantum-mechanical noise in an interferometer. Phys. Rev. D 23, 8 (1980).DOI
  6. [6]C. L. Degen, F. Reinhard, P. Cappellaro, Quantum sensing. Rev. Mod. Phys. 89, 035002 (2017).DOI
  7. [7]S. Kotler, N. Akerman, Y. Glickman, A. Keselman, R. Ozeri, Single-ion quantum lock-in amplifier. Nature 473, 61-65 (2011).
  8. [8]E. Kim, A. Safavi-Naini, D. A. Hite, K. S. McKay, D. P. Pappas, P. F. Weck, and H. R. Sadeghpour, Electric-field noise from carbon-adatom diffusion on a Au(110) surface: First-principles calculations and experiments. Phys. Rev. A 95, 033407 (2017).DOI
  9. [9]K. A. Gilmore, J. G. Bohnet, B. C. Sawyer, J.W. Britton, and J. J. Bollinger, Amplitude sensing below the zero-point fluctuations with a two-dimensional trapped-ion mechanical oscillator. Phys. Rev. Lett. 118, 263602 (2017).DOI
  10. [10]M. Affolter, K. A. Gilmore, J. E. Jordan and J. J. Bollinger, Phase-coherent sensing of the center-of-mass motion of trapped-ion crystals. Phys. Rev. A 102, 052609 (2020).DOI
  11. [11]K. A. Gilmore, M. Affolter, R. J. Lewis-Swan, D. Barberena, E. Jordan, A. M. Rey and J. J. Bollinger. Quantum-enhanced sensing of displacements and electric fields with large trapped-ion crystals. arXiv:2103.08690.DOI
  12. [12]S. Knünz, M. Herrmann, V. Batteiger, G. Saathoff, T. W. Hänsch, K. Vahala, T. Udem, Injection-lock of a trapped-ion phonon laser. Phys. Rev. Lett. 105, 013004 (2010).pubmed.ncbi.nlm.nih.gov/20867440
  13. [13]M. J. Biercuk, H. Uys, J. W. Britton, A. P. VanDevender, J. J. Bollinger, Ultrasensitive detection of force and displacement using trapped ions. Nat. Nanotechnol. 5, 646-650 (2010).DOI
  14. [14]R. Shaniv, R. Ozeri, Quantum lock-in force sensing using optical clock Doppler velocimetry. Nat. Commun. 8, 14157 (2017).DOI
  15. [15]V. Blūms, M. Piotrowski, M. I. Hussain, B. G. Norton, S. C. Connell, S. Gensemer, M. Lobino, E. W. Streed, A single-atom 3D sub-attonewton force sensor. Sci. Adv. 4, 4453 (2018).DOI
  16. [16]G. Araneda, S. Walser, Y. Colombe, D. B. Higginbottom, J. Volz, R. Blatt, A. Rauschenbeute, Wavelength-scale errors in optical localization due to spin-orbit coupling of light. Nat. Phys. 15, 17-21 (2019).DOI
  17. [17]V. Natarajan, F. DiFilippo, D. E. Pritchard, Classical squeezing of an oscillator for subthermal noise operation. Phys. Rev. Lett. 74, 2855 (1995).pubmed.ncbi.nlm.nih.gov/10058043
  18. [18]K. Vahala, M. Herrmann, S. Knünz, V. Batteiger, G. Saathoff, T. W. Hänsch and T. Udem, A phonon laser. Nat. Phys. 5, 682-686 (2009).
  19. [19]I. S. Grudinin, H. Lee, O. Painter, K. J. Vahala, Phonon laser action in a tunable two-level system. Phys. Rev. Lett. 104, 083901 (2010).
  20. [20]M. Ip, A. Ransford, A. M. Jayich, X. Long, C. Roman, and W. C. Campbell, Phonon lasing from optical frequency comb illumination of trapped ions. Phys. Rev. Lett 121, 043201 (2018).DOI
  21. [21]B. He, L. Yang, M. Xiao, Dynamical phonon laser in coupled active-passive micror resonators. Phys. Rev. A 94, 031802 (2016).DOI
  22. [22]M. R. Hush, W. Li, S. Genway, I. Lesanovsky, A. D. Armour, Spin correlations as a probe of quantum synchronization in trapped-ion phonon lasers. Phys. Rev. A 91, 061401 (2015).DOI
  23. [23]F. Dominguez, I. Arrazola, J. Doménech, J. S. Pedernales, L. Lamata, E. Solano, D. Rodriguez1, A single-ion reservoir as a high-sensitive sensor of electric signals. Sci. Rep. 7, 8336 (2017).DOI
  24. [24]M. Brownnutt, M. Kumph, P. Rabl, R. Blatt, Ion-trap measurements of electric-field noise near surfaces. Rev. Mod. Phys. 87, 1419 (2015).DOI
  25. [25]W. Wan, H. Y. Wu, L. Chen, F. Zhou, S. J. Gong, and M. Feng, Demonstration of motion transduction in a single-ion nonlinear mechanical oscillator. Phys. Rev. A 89, 063401 (2013).DOI
  26. [26]Z. C. Liu, L. Chen, Ji Li, H. Zhang, C. Li, F. Zhou, S. L. Su, L. L. Yan, M. Feng, Structural phase transition of the ion crystals embedded in an optical lattice. Phys. Rev. A 102, 033116 (2020).DOI
  27. [27]M. G. House, Analytic model for electrostatic fields in surface-electrode ion traps. Phys. Rev. A 78, 033402 (2008).DOI
  28. [28]L. L. Yan, S. L. Su, and M. Feng, Analytical investigation of one-dimensional Doppler cooling of trapped ions in a Λ-type configuration. Phys. Rev. A 100, 033418 (2019).DOI
  29. [29]D. Leibfried, R. Blatt, C. Monroe, D. Wineland, Quantum dynamics of single trapped ions. Rev. Mod. Phys. 75, 281 (2003).DOI
  30. [30]E. Majorana, Y. Ogawa, Mechanical thermal noise in coupled oscillators. Phys. Lett. A 233, 162-168 (1997).DOI
  31. [31]T. Briant, P. F. Cohadon, M. Pinard, A. Heidmann, Optical phase-space reconstruction of mirror motion at the attometer level. Eur. Phys. J. D 22, 131-140 (2003).DOI
  32. [32]E. E. Wollman, C. U. Lei, A. J. Weinstein, J. Suh, A. Kronwald, F. Marquardt, A. A. Clerk, K. C. Schwab, Quantum squeezing of motion in a mechanical resonator. Phys. Rev. A 349, 952-955 (2015).DOI
  33. [33]S. C. Burd, R. Srinivas, J. J. Bollinger, A. C. Wilson, D. J. Wineland, D. Leibfried, D. H. Slichter, D. T. C. Allcock, Quantum amplification of mechanical oscillator motion. Science 364, 1163-1165 (2019).DOI
  34. [34]J. Li, L. Chen, Y. H. Chen, Z. C. Liu, H. Zhang, and M. Feng, Three-Dimensional Compensation for Minimizing Heating of the Ion in Surface-Electrode Trap. Chin. Phys. Lett. 37, 053701 (2020).DOI
  35. [35]S. Urabe, M. Watanabe, H. Imajo, K. Hayasaka, U. Tanaka and R. Ohmukai, Observation of Doppler sidebands of a laser-cooled Ca+ ion by using a low-temperature-operated Laser diode. Apply. Phys. B 67, 223 (1998).DOI
  36. [36]D. Rugar and P. Gritter, Mechanical parametric amplification and thermomechanical noise squeezing. Phys. Rev. Lett. 67, 6 (1991).pubmed.ncbi.nlm.nih.gov/10044966
  37. [37]W. C. Campbell, and P. Hamilton, Rotation sensing with trapped ions. J. Phys. B 50, 064002 (2017).

Paper details

vlnc:W_kn2buru6
Version
v1 · latest
Published
Fresh — added to the Hub within the last 30 days
Added
License
CC BY 4.0
Usage

views · 0

downloads · 0

A view counts once per browser per day, a download each time the PDF is requested.

  • Physics and Astronomy

Not recorded for this paper

View statement
Looking for related papers…
Contents